CEILING SLAB PROVIDE 18/4, UNSHIELDED CABLE (BELDEN #9157), CLASS 2 CABLING DOOR HARDWARE- POWER ARDWARE POWER SUPPLY i SUSPENDED CEILING PROVIDE 22/6, SHIELDED CABLE (BELDEN #9942) TO EXISTING ACCESS CONTROL PANEL LOCATED IN PHILLIPS HALL LAB 328 (APPROX. 200 -FEET). STUB -OUT WALL ABOVE CEILING CARD READER ELECTRIFIED MORTISE LOCK w CABLE ROUTED THROUGH DOOR QC CONNECTORS CABLE ROUTED THROUGH 1" CONDUIT CABLE ROUTED IN DOOR FRAME -QC CONNECTORS POWER TRANSFER DEVICE DOOR FIN FLR KEY NOTES DO NOT REMOVE QC CONNECTORS FROM POWER TRANSFER DEVICE AND SUPPLIED CABLES. 3 TYPICAL CARD ACCESS @ INTERIOR DOORS Scale: N.T.S. EMERGENCY SHUTDOWN o PUSHBUTTON PP -338B 300A ° 3P Eo - ST 4#350, 1#4GND, IN 3"C HP -01 (ETR) EXISTING 400A FEEDER 300A 3P (ETR) EXISTING 208V DISTRIBUTION PANELBOARD "NEW 208V PANEL -2" THIRD FLOOR SECOND FLOOR SECOND FLOOR FIRST FLOOR FIRST FLOOR BASEMENT \-PULLBOX IN BASEMENT 4#350, 1#4GND, IN 3"C 1 PARTIAL ONE -LINE DIAGRAM Scale: N.T.S. LIGHTING FIXTURE SCHEDULE TYPE MANUFACTURER CAT. NUMBER TYPE COLOR LUMENS VOLTAGE WATTS CRI MOUNTING DESCRIPTION LA CORELITE RZL-WL-30L840-1D-UNV-STD- W-AC48-JB-XX LED 4000K 841/FT 120 6.2/FT >_80 AIRCRAFT CABLE SUSPENDED LED SEMI -DIRECT LUMINAIRE WITH TRAPEZODIAL SHAPE AND FROSTED LENS. SHALL BE MOUNTED IN CONTINUOUS ROWS. PANELBOARD PP -338B LOCATION: ROOM 338B MAIN BUS AMPS: 300A SERVICE VOLTAGE: 208Y/120V, 3PH, 4W MAIN CIRCUIT BREAKER: 300A SHUNT -TRIP MOUNTING: SURFACE FEEDER SIZE: REFER TO ONE -LINE DIAGRAM FEED: NEW 208V PANEL -2 FEED THRU LUGS: NONE S.C. RATING: 10,000 AMPS RMS SYM. DESCRIPTION PHASE AMPS TRIP AMPS POLES TRIP AMPS PHASE AMPS DESCRIPTION PH A PH B PH C PH A PH B PH C REC. - WEST RACEWAY 333B 4.5 20A/1 P 1 2 20A/1 P 3.0 REC. - WEST RACEWAY 333B REC. - EAST RACEWAY 333B 4.5 20A/1 P 3 4 20A/1 P 4.5 REC. - EAST RACEWAY 333B REC. - EAST RACEWAY 333C 4.5 20A/1 P 5 6 20A/1 P 4.5 REC. - EAST RACEWAY 333C REC. - WEST WALL 333C 3.0 20A/1 P 7 8 20A/1 P 4.5 REC. - TELE/POWER POLE 333B REC. - TELE/POWER POLE 333B 4.5 20A/1 P 9 10 20A/1 P 4.5 REC. - TELE/POWER POLE 333B REC. - TELE/POWER POLE 333B 4.5 20A/1 P 11 12 20A/1 P 3.0 REC. - SOUTH WALL 3000B DC POWER SUPPLY REC. - 338C 56.0 70A/3P 13 14 70A/3P 56.0 DC POWER SUPPLY REC. - 338B 56.0 15 16 56.0 56.0 17 18 56.0 DC POWER SUPPLY REC. - 338B 32.0 40A/3P 19 20 40A/3P 31.0 AC POWER SUPPLY REC. - 338B 32.0 21 22 31.0 32.0 23 24 ► SPARE 0.0 20A/1 P 25 26 20A/1 P 1.0 DOOR HARDWARE POWER SUPPLY SPARE 0.0 20A/1 P 27 28 20A/1 P 0.0 SP RE SPARE 0.0 20A/1 P 29 30 20A/1 P 0.0 SPARE SPARE 0.0 20A/1 P 31 32 20A/1 P 0.0 SPARE SPARE 0.0 20A/1 P 33 34 20A/1 P 0.0 SPARE SPARE 0.0 20A/1 P 35 36 20A/1 P 0.0 SPARE SPARE 0.0 20A/1 P 37 38 20A/1 P 0.0 SPARE SPARE 0.0 20A/1 P 39 40 20A/1 P 0.0 SPARE SPARE 0.0 20A/1 P 41 42 20A/1 P 0.0 SPARE 95.5 97.0 97.0 SUBTOTAL (AMPS) 95.5 96.0 94.5 PH. A PH. B PH.0 TOTAL PHASE AMPS 191.00 193.00 191.50 TOTAL PHASE kVA 22.92 23.16 22.98 TOTAL 3-PHASE kVA 69.06 TOTAL DEMAND 3-PHASE kVA 48.34 TOTAL DEMAND 3-PHASE AMPS 134.34 EXISTING 208V DISTRIBUTION PANELBOARD "NEW 208V PANEL -2" (ETR) EXISTING PULLBOX IN BASEMENT (FIELD VERIFY EXACT LOCATION) BASEMENT POWER - NEW WORK PLAN Scale: 1/8" = 11-0" ERDMAN ANTHONY 145 Culver Road Suite 200 Rochester, NY 14620-1678 Telephone 585 427 8888 Facsimile 585 427 8914 www.erdmananthony.com NOTE: UNAUTHORIZED ALTERATION OR ADDITION TO THIS DRAWING IS A VIOLATION OF THE NEW YORK STATE EDUCATION LAW ARTICLE 145, SECTION 7209. REVISIONS DESCRIPTION DATE 1 REV. BULLETIN BA -01 09/19/19 ALL RIGHTS RESERVED: NO PART OF THIS DOCUMENT MAY BE REPRODUCED, STORED IN A RETRIEVAL SYSTEM, OR TRANSMITTED, IN ANY FORM OR BY ANY MEANS ELECTRONIC, MECHANICAL, PHOTOCOPYING, RECORDING, OR OTHERWISE WITHOUT THE PRIOR WRITTEN AUTHORIZATION OF ERDMAN ANTHONY. COPYRIGHT © 2019 Erdman Anthony BID DOCUMENTS z O O z w O O m J CO • O M C.) coM co cn 0 0 M m M M J J Z (n 2 e91 DATE: 08.12.2019 PROJECT #: 1001X.29 DRAWN BY: DU CHECKED BY: BRW SCALE: AS NOTED RISERS, SCHEDULES, & DETAILS E-700 49. a a r — — — T — PENDANT MOUNTED l'x4' PRISMATIC WRAP (TYP.) a a a a FCU (ETR) r L — J- — — — J a a EXISTING ENCLOSED CABLETRAY (ETR) L— — —.......-L........., a L — — — _L — — — J a a L — — — J- — — — J a a (ETR) b 1 ENLARGED LIGHTING - DEMOLITION PLAN Scale: 1/4" = 11-0" LA a DS a LA a LA- a LASER IN—USE D1 ILLUMINATED SIGN LA a LA b LA a LA b LA — LA d d LA LA I=1 a,b V LA LA CS a,b V LA LA LA EXISTING ENCLOSED CABLETRAY (ETR) LA LA LA LA LA EM ENLARGED LIGHTING - NEW WORK PLAN 4. Scale: 1/4" = 11-0" DEMOLITION KEYED NOTES: Dl. DISCONNECT AND REMOVE EXISTING PENDANT MOUNTED LIGHT FIXTURES AND ASSOCIATED CONTROLS IN THEIR ENTIRETY. DISCONNECT AND REMOVE EXISTING BRANCH CIRCUITING BACK TO NEAREST CEILING MOUNTED JUNCTION BOX AND SAVE FOR REUSE. KEYED NOTES: 1. PROVIDE ADDITIONAL BRANCH CIRCUITING TO EXTEND AND RECONNECT EXISTING ROOM LIGHTING CIRCUIT TO NEW LIGHT FIXTURES AND CONTROL DEVICES. 2. CONNECT DESIGNATED EMERGENCY LIGHT FIXTURE TO EXISTING CORRIDOR EMERGENCY LIGHTING CIRCUIT. ERDMAN ANTHONY 145 Culver Road Suite 200 Rochester, NY 14620-1678 Telephone 585 427 8888 Facsimile 585 427 8914 www.erdmananthony.com NOTE: UNAUTHORIZED ALTERATION OR ADDITION TO THIS DRAWING IS A VIOLATION OF THE NEW YORK STATE EDUCATION LAW ARTICLE 145, SECTION 7209. REVISIONS DESCRIPTION DATE 1 REV. BULLETIN BA -01 09/19/19 ALL RIGHTS RESERVED: NO PART OF THIS DOCUMENT MAY BE REPRODUCED, STORED IN A RETRIEVAL SYSTEM, OR TRANSMITTED, IN ANY FORM OR BY ANY MEANS ELECTRONIC, MECHANICAL, PHOTOCOPYING, RECORDING, OR OTHERWISE WITHOUT THE PRIOR WRITTEN AUTHORIZATION OF ERDMAN ANTHONY. COPYRIGHT © 2019 Erdman Anthony BID DOCUMENTS z O O z w >- 0 O CO J CO • O M C.) coM oo 0 0 M m M M J J Z (n 2 U) co � Y wO »- z� Dw J Z W < ZU • Q O I • I— e91 DATE: 08.12.2019 PROJECT #: 1001X.29 DRAWN BY: DU CHECKED BY: BRW SCALE: AS NOTED ENLARGED LIGHTING PLAN EL -1 00 SINGLE COMPARTMENT (ETR) RACEWAY (00) (ETR) SINGLE COMPARTMENT RACEWAY (OC) 50W (ETR) 12,14 -PP -01 ( (ETF)ETR) 4-BP3-6A (ETR). (ETR) tga (ETR) PENDANT MOUNTED RECEPTACLE (ETR) tgt 1' 1,3,5 -HP -01 r 60 (ETR) IENLARGED POWER - DEMOLITION PLAN Scale: 1/4" = 1'-0" (ETR) (ETR) PP -01 (ETR) HP -01 (ETR) FCU FAN SPEED CONTROLLER (ETR) (ETR) $ (ETR) (ETR) SINGLE COMPARTMENT (ETR RACEWAY (00) TR) SINGLE COMPARTMENT RACEWAY (00) -6=5ORI (ETR) 12,14 -PP -01 OSINGLE COMPARTMENT RACEWAY (OC) 19,21,23 -PP -338B (ETR) 13,15,17 -PP -338B 14,16,18 -PP -338B (ETR)18"© 08 A.F.F. (ETR) 20,22,24 -PP -338B BP3-6A PP -338B (ETR) (ETR) FAN (ETR) EED NTROL BP3-6 (ETR)/ ENLARGED POWER - NEW WORK PLAN 4. Scale: 1/4" = 1'-0" PP -01 (ETR) (LOCATED ABOVE CEILING) PULLBOX (FORMER PANELBOARD HP -01) (ETR) EMERGENCY SHUTDOWN PUSHBUTTON 40" (ETR) A.F.F. .rn 26 -PP -338B GENERAL NOTES: G1. ELECTRICAL CONTRACTOR SHALL PAINT ALL NEW SURFACE MOUNTED RACEWAY, JUNCTION BOXES AND ASSOCIATED MOUNTING HARDWARE IN ROOMS 338B, 338C & 3000B TO MATCH EXISTING RACEWAY AND SURROUNDING SURFACES. COORDINATE EXACT FINISH WITH CORNELL PROJECT MANAGER. DEMOLITION KEYED NOTES: Dl. DISCONNECT AND REMOVE EXISTING DISCONNECT AND ASSOCIATED BRANCH CIRCUITING BACK TO SOURCE. D2. DISCONNECT AND REMOVE EXISTING DISCONNECT AND ASSOCIATED RECEPTACLE AND BRANCH CIRCUITING BACK TO SOURCE. D3. DISCONNECT AND REMOVE EXISTING MOTOR STARTER AND ASSOCIATED BRANCH CIRCUITING BACK TO SOURCE. D4. e e CAREFULLY DISCONNECT AND REMOVE EXISTING PANELBOARD TO ACCOMMODATE PANELBOARD RELOCATION. EXISTING WIREWAY LOCATED BELOW PANELBOARD SHALL ALSO BE REMOVED. ALL BRANCH CIRCUITING ENTERING WIREWAY SHALL BE REMOVED BACK TO LOCATION AS HIGH AS POSSIBLE ON EXISTING WALL. UPON COMPLETION OF AREA DEMOLITION WORK, EXTEND AND RECONNECT ALL REMAINING BRANCH CIRCUITING AND EXISTING PANELBOARD FEEDER TO NEW PANELBOARD LOCATION. ALL NEW JUNCTION BOXES REQUIRED FOR BRANCH CIRCUIT AND FEEDER RELOCATION WORK SHALL BE LOCATED AS HIGH AS POSSIBLE ON WALL OR CEILING. D5. DISCONNECT AND REMOVE EXISTING CORD DROP AND ASSOCIATED BRANCH CIRCUITING BACK TO SOURCE. D6. DISCONNECT AND REMOVE EXISTING PENDANT MOUNTED RECEPTACLE AND ASSOCIATED BRANCH CIRCUITING BACK TO SOURCE. D7. DISCONNECT AND REMOVE INTERNAL GUTS OF EXISTING PANELBOARD TO ALLOW PANELBOARD BACKBOX TO BE USED AS A PULLBOX. EXISTING PANELBOARD FEEDER SHALL REMAIN FOR REUSE. REPLACE EXISTING PANELBOARD COVER WITH NEW BLANK STEEL COVER. COVER SHALL BE PAINTED TO MATCH SURROUNDING SURFACE. D8. DISCONNECT AND REMOVE EXISTING ELECTRIFIED DOOR HARDWARE POWER AND CONTROL BRANCH CIRCUITING BACK TO SOURCE. KEYED NOTES: 1. PROVIDE BLACK TELE -POWER POLE CENTERED BETWEEN WORKBENCHES. RECEPTACLES SHALL BE MOUNTED ABOVE WORKBENCH WORKING SURFACE TO ALLOW WORKBENCH PLUGSTRIPS (PROVIDED BY OWNER) TO BE PLUGGED INTO RECEPTACLES. 2. RELOCATE EXISTING PANELBOARD TO LOCATION SHOWN. EXTEND AND RECONNECT EXISTING FEEDER AND BRANCH CIRCUITS. 3. PROVIDE SINGLE COMPARTMENT STEEL RACEWAY (WIREMOLD 3000) ALONG ENTIRE LENGTH OF WALL. PROVIDE QUANTITY OF RECEPTACLES INDICATED. RACEWAY SHALL BE MOUNTED AT APPROXIMATELY 40" A.F.F. (SHALL MATCH HEIGHT OF EXISTING RACEWAY IN ADJACENT ROOM 338B). 4. PROVIDE 100A, 3 -POLE, 4 -WIRE, STYLE II, PIN AND SLEEVE RECEPTACLE (HUBBELL #HBL4100RS2W) AND MOUNT DIRECTLY ABOVE RACEWAY. PROVIDE ONE (1) MATCHING PLUG (HUBBELL #HBL4100PS2W) AND 4 -FOOT 4/4 SOOW CABLE (#4 AWG, 4 -CONDUCTOR) AND CONNECT TO KEYSIGHT DC POWER SUPPLY UNIT (UNIT FURNISHED BY CORNELL). 5. RE -CIRCUIT ALL EXISTING RECEPTACLES IN RACEWAY. PROVIDE NEW BRANCH CIRCUITING BACK TO PANELBOARD PP -338B. 6. PROVIDE 50A, 3-PHASE, 250V NEMA 15-50R RECEPTACLE AND MOUNT DIRECTLY ABOVE RACEWAY. PROVIDE ONE (1) MATCHING NEMA 15-50P PLUG AND 4 -FOOT 4/4 SOOW CABLE (#4 AWG, 4 -CONDUCTOR) AND CONNECT TO KEYSIGHT AC POWER SUPPLY UNIT (FURNISHED BY CORNELL). 7. PROVIDE 50A, 3-PHASE, 250V NEMA 15-50R RECEPTACLE AND MOUNT DIRECTLY ABOVE RACEWAY. PROVIDE ONE (1) MATCHING NEMA 15-50P PLUG AND 4 -FOOT 6/4 SOOW CABLE (#6 AWG, 4 -CONDUCTOR) AND CONNECT TO MAGNA POWER ELECTRONICS DC POWER SUPPLY UNIT (FURNISHED BY CORNELL). 8. UNLESS NOTED OTHERWISE, ALL 120V BRANCH CIRCUITS IN THIS AREA SHALL BE FED FROM PANELBOARD PP -338B AND UTILIZE 2#12, 1#12 GND. IN 3/4"C. 9. PROVIDE NEW PANELBOARD AT LOCATION SHOWN. PANELBOARD SHALL BE PROVIDED WITH SHUNT -TRIP MAIN CIRCUIT BREAKER CONTROLLED BY EMERGENCY SHUTDOWN PUSHBUTTON. REFER TO PARTIAL ONE -LINE DIAGRAM ON DRAWING E-700 FOR ADDITIONAL WORK. 10. PROVIDE POWER AND CONTROL BRANCH CIRCUITING FOR NEW ELECTRIFIED DOOR HARDWARE EQUIPMENT. REFER TO DETAIL 3/E-700 FOR INSTALLATION AND CABLE REQUIREMENTS. ERDMAN ANTHONY 145 Culver Road Suite 200 Rochester, NY 14620-1678 Telephone 585 427 8888 Facsimile 585 427 8914 www.erdmananthony.com NOTE: UNAUTHORIZED ALTERATION OR ADDITION TO THIS DRAWING IS A VIOLATION OF THE NEW YORK STATE EDUCATION LAW ARTICLE 145, SECTION 7209. REVISIONS DESCRIPTION DATE 1 REV. BULLETIN BA -01 09/19/19 ALL RIGHTS RESERVED: NO PART OF THIS DOCUMENT MAY BE REPRODUCED, STORED IN A RETRIEVAL SYSTEM, OR TRANSMITTED, IN ANY FORM OR BY ANY MEANS ELECTRONIC, MECHANICAL, PHOTOCOPYING, RECORDING, OR OTHERWISE WITHOUT THE PRIOR WRITTEN AUTHORIZATION OF ERDMAN ANTHONY. COPYRIGHT © 2019 Erdman Anthony BID DOCUMENTS z O O z w >- 0 O CO J CO O M C.) coM M com Mcn 0 0 M J J Z (n 2 e91 DATE: 08.12.2019 PROJECT #: 1001X.29 DRAWN BY: DU CHECKED BY: BRW SCALE: AS NOTED ENLARGED POWER PLANS EP -100 (ETR) EXISTING INACTIVE WALL MOUNTED DATA CABINET (ETR) EXISTING RACEWAY FROM CABLETRAY 3D 3D 3D EXISTING ENCLOSED CABLETRAY (ETR) IENLARGED TELECOMMUNICATION - DEMOLITION PLAN Scale: 1/4" = 1'-0" (ETR) EXISTING INACTIVE WALL MOUNTED DATA CABINET (ETR) EXISTING RACEWAY FROM CABLETRAY VERTICAL RUN OF DUAL - COMPARTMENT RACEWAY (TYP.) EXISTING ENCLOSED CABLETRAY (ETR) ENLARGED TELECOMMUNICATION - NEW WORK PLAN 4. Scale: 1/4" = 1'-0" DEMOLITION KEYED NOTES: Dl. DISCONNECT AND REMOVE EXISTING DATA OUTLETS AND ASSOCIATED RACEWAY IN THEIR ENTIRETY. DISCONNECT AND REMOVE DATA CABLING BACK TO IT CLOSET ROOM 334. GENERAL NOTES: G PROVIDE, ROUTE AND TERMINATE ALL CAT 6 HORIZONTAL DATA CABLING FROM DATA OUTLET BACK TO DATA RACK IN EXISTING IT CLOSET ROOM 334. PROVIDE MINIMUM 1 -INCH EMT CONDUIT OR EQUIVALENT RACEWAY FROM SINGLE GANG OUTLET BOX TO EXISTING CABLETRAYS IN ROOM AND CORRIDOR TO ROUTE CABLING BACK TO IT CLOSET. COORDINATE FINAL TERMINATIONS AND TESTING WITH OWNER. KEYED NOTES: 1. PROVIDE QUANTITY OF DATA OUTLETS INDICATED ON EITHER SIDE OF TELE -POWER POLE. OUTLETS SHALL BE MOUNTED ABOVE WORKBENCH WORKING SURFACE TO ALLOW WORKBENCH COMPUTERS (PROVIDED BY OWNER) TO BE PLUGGED INTO OUTLETS. 2. PROVIDE QUANTITY OF DATA OUTLETS INDICATED AND SURFACE MOUNT DIRECTLY ABOVE POWER RACEWAY. ERDMAN ANTHONY 145 Culver Road Suite 200 Rochester, NY 14620-1678 Telephone 585 427 8888 Facsimile 585 427 8914 www.erdmananthony.com NOTE: UNAUTHORIZED ALTERATION OR ADDITION TO THIS DRAWING IS A VIOLATION OF THE NEW YORK STATE EDUCATION LAW ARTICLE 145, SECTION 7209. REVISIONS DESCRIPTION DATE 1 REV. BULLETIN BA -01 09/19/19 ALL RIGHTS RESERVED: NO PART OF THIS DOCUMENT MAY BE REPRODUCED, STORED IN A RETRIEVAL SYSTEM, OR TRANSMITTED, IN ANY FORM OR BY ANY MEANS ELECTRONIC, MECHANICAL, PHOTOCOPYING, RECORDING, OR OTHERWISE WITHOUT THE PRIOR WRITTEN AUTHORIZATION OF ERDMAN ANTHONY. COPYRIGHT © 2019 Erdman Anthony BID DOCUMENTS z O O z w >- 0 O CO J m O M C.) coM M oo MMcn 0 0 m J J Z (n 2 e91 DATE: 08.12.2019 PROJECT #: 1001X.29 DRAWN BY: DU CHECKED BY: BRW SCALE: AS NOTED ENLARGED TELECOMMUNICATION PLANS ET -100 C INSTALL PIPING TIGHT TO THE BOTTOM OF STEEL BEAM 0 4" FP MAIN II GENERAL NOTES: G1. SPRINKLER ZONE THIRD FLOOR ROOMS 338B, 338C, AND 300UB 1260 SQ.FT. ORDINARY HAZARD, MINIMUM DENSITY OF 0.15 GPM OVER THE REMOTE 1500 SQ.FT AREA. ORDINARY TEMPERATURE SPRINKLER HEADS, WET PIPE SYSTEM. G2. THE PLANS INDICATE ONLY PART OF THE GENERAL ARRANGEMENT OF PIPING, SIZING AND EQUIPMENT. EXACT LOCATION OF ALL EXISTING ELEMENTS SHALL BE DETERMINED AS WORK PROGRESSES, IN COOPERATION AND COORDINATION WITH THE WORK OF ALL TRADES. THEY ARE NOT INTENDED TO SHOW EVERY ITEM OF WORK OR MINOR PIECE OF EQUIPMENT. G3. CONTRACTOR SHALL FIELD VERIFY PIPE SIZES PRIOR TO THE BEGINNING ANY WORK. G4. INSTALL ALL PIPING TO AVOID INTERFERENCE WITH THE OPERATION, SERVICE, AND MAINTENANCE OF EXISTING AND/OR NEW EQUIPMENT. G5. THE CONTRACTOR SHALL COORDINATE ALL INSTALLATIONS WITH LATEST ARCHITECTURAL, MECHANICAL AND ELECTRICAL DRAWINGS. G6. THE LOCATION OF FIRE PROTECTION MAIN AND BRANCH PIPING AND SPRINKLER HEADS MAY DIFFER FROM THE ACTUAL LOCATION AND ELEVATION. KEYED NOTES: 0 1. PROVIDE TAKE OFF FOR NEW FIRE MAIN FROM 4" FIRE MAIN SERVING THIRD FLOOR OFFICES. ROUTE NEW FIRE MAIN ABOVE CORRIDOR CEILING AND IN COORDINATION WITH EXISTING TRADES. REMOVE AND RE -INSTALL CEILING TIMES AND GRID AS NEEDED TO INSTALL PIPING AND HEADS. 2. PROVIDE UPRIGHT SPRINKLER HEADS IN ROOMS 338B, 338C, AND 300UB. ROUTE BRANCH PIPING TO AVOID INTERFERENCES WITH EXISTING TRADES. 3. PROVIDE FULL PORT BALL VALVES AT THE END OF BRANCH LINES AND MAIN PIPING TO FACILITATE FUTURE FLUSHING OF THE SYSTEM, PER CORNELL STANDARDS. 4. PROVIDE CONCEALED PENDENT SPRINKLER HEADS IN CORRIDOR DROP CEILING. ROUTE BRANCH PIPING TO AVOID INTERFERENCES WITH EXISTING TRADES ABOVE CEILING. IENLARGED FIRE PROTECTION - NEW WORK PLAN Scale: 1/4" = 1'-0" ERDMAN ANTHONY 145 Culver Road Suite 200 Rochester, NY 14620-1678 Telephone 585 427 8888 Facsimile 585 427 8914 www.erdmananthony.com NOTE: UNAUTHORIZED ALTERATION OR ADDITION TO THIS DRAWING IS A VIOLATION OF THE NEW YORK STATE EDUCATION LAW ARTICLE 145, SECTION 7209. REVISIONS DESCRIPTION DATE 1 REV. BULLETIN BA -01 09/19/19 ALL RIGHTS RESERVED: NO PART OF THIS DOCUMENT MAY BE REPRODUCED, STORED IN A RETRIEVAL SYSTEM, OR TRANSMITTED, IN ANY FORM OR BY ANY MEANS ELECTRONIC, MECHANICAL, PHOTOCOPYING, RECORDING, OR OTHERWISE WITHOUT THE PRIOR WRITTEN AUTHORIZATION OF ERDMAN ANTHONY. COPYRIGHT © 2019 Erdman Anthony BID DOCUMENTS z O O z w >- 0 O CO J CO • O M C.) coM co cn 0 0 M m M M J J Z (n 2 C) U) co wO »- z Dw J Z w < ZU CC Q 0I I— e91 DATE: 08.12.2019 PROJECT #: 1001X.29 DRAWN BY: LY CHECKED BY: BRW SCALE: AS NOTED ENLARGED FIRE PROTECTION PLAN FP -100 EXISTING WINDOW TO BE REMOVED. INSTALL NEW WINDOW IN EXISTING OPENING, SEE HEIGHT AND WIDTH NOTES (THIS SHEET). 2 PHOTO DETAIL Scale: NTS KEYED NOTES: 1. REMOVE EXISTING WINDOW ASSEMBLY AND PREPARE SURFACES FOR INSTALLATION OF NEW. INSTALL NEW WINDOW IN EXISTING OPENING. BASIS OF DESIGN FOR WINDOW IS GRAHAM 2000 SERIES THERMAL WINDOW, SINGLE HUNG - 3 1/4", CLEAR ANODIZED FINISH. MANUFACTURER TO PROVIDE ALL NECESSARY ANCHORS AND RECEPTORS. PROVIDE SILL PANNING TO COVER EXISTING OPENING SILL. PROVIDE FLASHINGS AT WINDOW PERIMETER. SEE VENTILATION REQUIREMENTS (THIS SHEET) AND VERIFY OPERABLE PORTION OF WINDOW CONFORMS WITH DESIGN. INCLUDE INSECT SCREEN ON ALL OPERABLE WINDOWS. WINDOW TO CONTAIN 3 OPERABLE SASHES, DIMENSIONS AND FRAMING LAYOUT TO MATCH EXISTING AND ADJACENT WINDOWS TO REMAIN. REMOVE AND REINSTALL EXISTING WINDOW SHADES. CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR THE WINDOW REPLACEMENT INCLUDING ALL JAMB, HEAD, AND SILL DETAILS WITH ALL ANCHORS, PANNING, AND FLASHING. SHOP DRAWINGS SHALL ALSO INCLUDE EXISTING WINDOW AND OPENING CONDITIONS INFORMATION FOR COMPARISON TO THE NEW WINDOWS. 2. REMOVE EXISTING DOOR. EXISTING DOOR OPENING - 20 SQFT TO REMAIN. 3. PROVIDE AND INSTALL DUCT TRANSFER OPENING - 5 SQFT Natural Ventilation Window Dimensions Total window height: Total window width: Openable height: Total area open per window: p 5.83 ft 3.67 ft 2.75 ft 10.1 ft2 Level Space Name AHU Floor Area oft)Outdoors Window Openable Area to (ft) (ft2) # Openable Windows % Openable to Floor Area 3 Classroom 3386 -- 849 40.4 4 4.76% 3 Classroom 338C -- 266 20.2 2 7.59% 3 Classroom 300UB -- 116 0 0 0.00% 3 TOTAL 1231 60.6 6 4.92% 1 ENLARGED VENTILATION PLAN Scale: 1/4" = 1'-0" NA ! RAL VENTLA ON [BGI402.1 Natural Natural ventitabon of an occupied ace aba l e through windows, doors, , louvers o access so that t openings are readily controllable by the budding occupants. Ventilation area required. The minit n ; open ble areato the outdoor aba I be her openings o e cent of t e oer area ei ertila e. [BGI402.3Adjoining spaces. . : , Whererooms spaces without U ei il1 S totheout eery are ventilatedt r rr..n an of l rUo than 8 percent of the floor area of the interior room or space, but not lea=s than 25 square feet (23 ventilated. e utdoors. The operatung ee anian o uch openings l l be provi ed wit ready the in he adjoining morns shall be unobstructed and shall have an area not less T e minimum openable area to the outdoors shall be based on the total 0. r area being ... ERDMAN ANTHONY 145 Culver Road Suite 200 Rochester, NY 14620-1678 Telephone 585 427 8888 Facsimile 585 427 8914 www.erdmananthony.com NOTE: UNAUTHORIZED ALTERATION OR ADDITION TO THIS DRAWING IS A VIOLATION OF THE NEW YORK STATE EDUCATION LAW ARTICLE 145, SECTION 7209. REVISIONS DESCRIPTION DATE 1 REV. BULLETIN BA -01 09/19/19 ALL RIGHTS RESERVED: NO PART OF THIS DOCUMENT MAY BE REPRODUCED, STORED IN A RETRIEVAL SYSTEM, OR TRANSMITTED, IN ANY FORM OR BY ANY MEANS ELECTRONIC, MECHANICAL, PHOTOCOPYING, RECORDING, OR OTHERWISE WITHOUT THE PRIOR WRITTEN AUTHORIZATION OF ERDMAN ANTHONY. COPYRIGHT © 2019 Erdman Anthony BID DOCUMENTS z O O z w >- 0 O CO J CO Mco MMco 0 0 O m M J J Z (n 2 e91 DATE: 08.12.2019 PROJECT #: 1001X.29 DRAWN BY: AST CHECKED BY: SCALE: AS NOTED NATURAL VENTILATION PLAN M - 1 0 0 PHILLIPS HALL ROOMS 338B; 338C; 300UB LABORATORY RENOVATION PHILLIPS HALL PROJECT LOCATION CORNELL UNIVERSITY ITHACA, NEW YORK 14853 PROJECT NO. 1001X.29 DRAWING LIST G-001 A-101 FP -000 FP -100 FP -500 FA -100 M-100 E-000 EL -100 EP -100 ET -100 E-700 COVER SHEET 3RD FLOOR PLAN, DOOR SCHEDULE, AND DETAILS DRAWING NOTES ENLARGED FIRE PROTECTION PLAN FIRE PROTECTION DETAILS ENLARGED FIRE ALARM PLANS ENLARGED VENTILATION PLAN GENERAL NOTES & SYMBOLS ENLARGED LIGHTING PLAN ENLARGED POWER PLANS ENLARGED TELECOMMUNICATION PLANS RISERS, SCHEDULES, & DETAILS ERDMAN ANTHONY 145 Culver Road Suite 200 Rochester, NY 14620-1678 Telephone 585 427 8888 Facsimile 585 427 8914 www.erdmananthony.com NOTE: UNAUTHORIZED ALTERATION OR ADDITION TO THIS DRAWING IS A VIOLATION OF THE NEW YORK STATE EDUCATION LAW ARTICLE 145, SECTION 7209. REVISIONS DESCRIPTION DATE ALL RIGHTS RESERVED: NO PART OF THIS DOCUMENT MAY BE REPRODUCED, STORED IN A RETRIEVAL SYSTEM, OR TRANSMITTED, IN ANY FORM OR BY ANY MEANS ELECTRONIC, MECHANICAL, PHOTOCOPYING, RECORDING, OR OTHERWISE WITHOUT THE PRIOR WRITTEN AUTHORIZATION OF ERDMAN ANTHONY. COPYRIGHT © 2019 Erdman Anthony BID DOCUMENTS z O O z w >- 0 O CO J CO Mco MMco cn 0 0 O m M M J J Z (n 2 C) co wO »- Z D w J Z W < ZU • Q O I • I- e91 DATE: 08.12.2019 PROJECT #: 1001X.29 DRAWN BY: MSM CHECKED BY: AST SCALE: AS NOTED COVER SHEET G-001 1 Partial 3rd Floor Plan - Demolition Scale: 1/4" = 1'-0" 2 Partial 3rd Floor Plan - New Work Scale: 1/4" = 1'-0" DOOR AND FRAME SYSTEM SCHEDULE: DOOR NO. ROOM NAME DOOR FRAME DETAIL/SHEET FIRE RATING HARDWARE SET NO. REMARKS TYPE MATERIAL # OF LEAFS NOMINAL SIZE GLAZING TYPE MATERIAL FINISH HEAD JAMB THRESHOLD WIDTH HEIGHT THICKNESS 1/338B LAB 338B D1 WD 1 2'-10" 7'-0" 1 3/4" - F1 HM PT EX. J1 T1 1 HOUR 1 PROVIDE ACCESS CONTROL GENERAL NOTES: 1. ALL INTERIOR DOOR HARDWARE LOCK SETS ARE SARGENT "STANDARD LEVER, STYLE LN L" MORTISE LOCKS OR APPROVED EQUAL. 2. REFER TO FLOOR PLAN FOR DOOR SWING. 3. EXISTING LINTEL/HEADER TO REMAIN. EXISTING OPENING TO BE RE -USED. DOOR AND FRAME TO BE FIELD VERIFIED PRIOR TO FABRICATION. 4. ALL KEYING TO MATCH EXISTING BUILDING KEYING. 5. ALL ACCESS CONTROL COMPONENTS AND ACCESSORIES SHALL BE VERIFIED WITH THE OWNER PRIOR TO ORDERING. 6. OPENING FORCE ON ALL DOORS SHALL NOT EXCEED 5 POUNDS. 7. HARDWARE SHALL COME FROM A SINGLE SOURCE. SUBSTITUTIONS TO THE SETS BELOW IS SUBJECT TO APPROVAL BY ARCHITECT AND UNIVERSITY. 8. DOOR CLOSER SHALL BE LOCATED ON THE INTERIOR (NON -CORRIDOR) SIDE. 9. SEE ELECTRICAL DRAWINGS FOR ADDITIONAL ACCESS CONTROL INFORMATION. MAKE CONNECTION TO PANEL LOCATED IN LAB 328. 10. WOOD DOOR VENEER: RIFT SAWN WHITE OAK, CENTER BALANCE MATCHED. SUBMIT SAMPLES TO MATCH EXISTING DOORS TO REMAIN. 11. PROVIDE INTERIOR ROOM SIGNAGE FOR EACH NEW DOOR AND AS INDICATED ON THE PLANS. DOOR ELEVATION SCALE: 1/4" = 1'-0' SEE SCHEDULE /SEE SCH. / -D1- FIRE-RATED SOLID CORE WOOD 3 Door & Frame Elevations Scale: 1/4" = 1'-0" FRAME ELEVATION SCALE: 1/4" = 1' - w v� 0 0 0 DOOR SIZE 2- SEE SCH. w J w 0 cn w LU U) OPEN -F1- FULLY WELDED HOLLOW METAL J1 JAMB DETAIL CONTINUOUS BEAD OF SEALANT AROUND PERIMETER OF FRAME, TYP. BOTH SIDES HOLLOW METAL FRAME GROUTED SOLID, THROUGH BOLT IN EXIST. WALL EXISTING BLOCK WALL 1 1/2" = 1'-O" 4 Door Details Scale: 1 1/2" = 1'-0" 1 HARDWARE SCHEDULE: SET 1 1 MORTISE LOCK - ELECTRIC 1 WIRING HARNESS 1 ELECTRONIC POWER TRANSFER 1 POWER SUPPY 1 DOOR POSITION 3 4 i" STD. WT. HINGES 3 SILENCERS (PUSH IN) 1 FLOOR STOP 1 DOOR SEAL 1 AUTOMATIC DOOR BOTTOM (MORTISED) 1 SURFACE MOUNTED DOOR CLOSER SARGENT M1 -82271-24V X BIPS X LNL US10 MCKINNEY SECURITRON SECURITRON SECURITRON MCKINNEY DCI NGP PEMKO SARGENT QC-C1500P EL-CEPT-10 BPS -24-1 DPS -M -BK TA2714 GREY COLOR 3310 5050CL 411APKL 351 BK US10 US10 CLEAR A EP DOOR MORTISED DOOR AUTOMATIC BOTTOM SOUND SEAL EXISTING FLOOR FINISH FINISH FLOOR THRESHOLD DETAIL -1 1 1/2" = 1'-0" G) 9„ GENERAL NOTES: G1. REFER TO ELECTRICAL DRAWINGS FOR COMPLETE SCOPE OF WORK. G2. FURNITURE IS EXISTING TO REMAIN, U.O.N. G3. ALL FINISHES ARE EXISTING TO REMAIN, U.O.N. G4. PATCH AND REPAIR ALL ADJACENT SURFACES TO THE NEW WORK. KEYED NOTES: 1. REMOVE EXISTING DOOR AND FRAME COMPLETELY. EXISTING LINTEL/HEADER TO REMAIN..PREPARE SURFACES TO RECEIVE NEW DOOR AND FRAME. 2. REMOVE AND REINSTALL EXISTING ACOUSTICAL CEILING TILE AND GRID IN THE EXTENT REQUIRED TO REMOVE AND REINSTALL THE NEW DOOR FRAME. THE CEILING GRID HEIGHT IS AT THE DOOR FRAME HEIGHT. 3. NEW WOOD DOOR AND HOLLOW METAL FRAME. ADJUST OPENING AS REQUIRED FOR INSTALLATION. SEE DOOR SCHEDULE AND DETAILS, THIS SHEET. 4. NEW WALL SIGN. SEE DETAIL, THIS SHEET. SIGNAGE TO MATCH EXISTING BUILDING SIGNACE. 5. PROVIDE BLOCK WALL REPAIR AND PAINTING AS REQUIRED AROUND THE NEW DOOR AND FRAME. ROOM IDENTIFICATION SIGN W/ CHANGEABLE INSERTS 4 Signage Detail Scale: 6" = 1'-0" "I 5 Signage Mounting Elevation Scale: 1/4" = 1'-0" WALL BLACK ACRYLIC BACKER RAISED CHARACTERS AND BRAILLE PLASTIC SIGN FIELD CLEAR WINDOW FOR PAPER INSERT BEHIND CE FOR PAPER INSERT PAPER INSERT (BY OWNER) PLASTIC SIGN FIELD /1 / NOTE: NEW SIGN TO MATCH EXISTING BUILDING SIGNAGE. GC TO VERIFY IN FIELD. Interior Room Identification Signage: 1. SUBMIT SHOP DRAWINGS SHOWING SCHEDULE LAYOUT, PROFILES AND PRODUCT COMPONENTS, INCLUDING MATERIAL DETAILS, DIMENSIONS, ANCHORAGE, AND ACCESSORIES FOR ARCHITECT'S REVIEW AND APPROVAL BEFORE STARTING FABRICATION. 2. ALL SIGNAGE SYSTEMS SHALL MEET REQUIREMENTS OF THE AMERICANS WITH DISABILITIES ACT ACCESSIBILITY GUIDELINES (ADAAG) AND LOCAL AMENDMENTS AND MODIFICATIONS. 3. RAISED LETTERING AND/OR NUMERALS: COMPUTER—CUT CHARACTERS WITH MATTE FINISH, COLOR AS SPECIFIED FROM MANUFACTURER'S STANDARD COLOR CHART. SHALL EXTEND A MINIMUM OF 1/32" FROM THE SIGN SURFACE. PHOTOPOLYMER TAGS SHALL NOT BE ACCEPTABLE. / 4. GRADE 2 BRAILLE: CLEAR RASTER BALLS COMPUTER DRILLED AND PRESSURE INSERTED INTO SIGN FACE. SHALL BE HALF—HEMISPHERE IN SHAPE AND SHALL EXTEND A MINIMUM OF 0.025" FROM THE SIGN SURFACE. OTHER METHODS OF MANUFACTURE, INCLUDING SURFACE APPLIED PHOTOPOLYMER BRAILLE TAGS SHALL NOT BE ACCEPTABLE. 5. FASTENER: VERY HIGH BOND (VHB) .030 INCH THICK DOUBLE—FACE TAPE FINISHES COLORS: AS SELECTED FROM THE MANUFACTURER'S STANDARD CHART. PATTERNS: AS SELECTED FROM THE MANUFACTURER'S STANDARD CHART. EE `[OMAN ANTHONY 145 Culver Road Suite 200 Rochester, NY 14620-1678 Telephone 585 427 8888 Facsimile 585 427 8914 ww w. e rdm on antho ny.com Richard McElhiney Architects LLC 347 West 36 St Floor 15 New York, NY 10018 212-245-5195t 212-239-7130 f NOTE: UNAUTHORIZED ALTERATION OR ADDITION TO THIS DRAWING IS A VIOLATION OF THE NEW YORK STATE EDUCATION LAW ARTICLE 145, SECTION 7209. REVISIONS DESCRIPTION DATE ALL RIGHTS RESERVED: NO PART OF THIS DOCUMENT MAY BE REPRODUCED, STORED IN A RETRIEVAL SYSTEM, OR TRANSMITTED, IN ANY FORM OR BY ANY MEANS ELECTRONIC, MECHANICAL, PHOTOCOPYING, RECORDING, OR OTHERWISE WITHOUT THE PRIOR WRITTEN AUTHORIZATION OF ERDMAN ANTHONY. COPYRIGHT © 2019 Erdman Anthony BID DOCUMENTS Z 0 0 z (1! w >- 0 O CO J m M • .. U co M M co 0 0 J J 2 (n 2 co • 1 � >- Z Z D W J Z J W < ZU • Q O I U1— Key Plan: eairiti° DATE: 08.12.2019 PROJECT #: 1001X.29 DRAWN BY: WRK CHECKED BY: RLM SCALE: AS NOTED 3RD FLOOR PLAN, DOOR SCHEDULE, AND DETAILS A-1 01 8' 338_, 0.0.0_0 as . 00 SP, ROOM IDENTIFICATION SIGN W/ CHANGEABLE INSERTS 4 Signage Detail Scale: 6" = 1'-0" "I 5 Signage Mounting Elevation Scale: 1/4" = 1'-0" WALL BLACK ACRYLIC BACKER RAISED CHARACTERS AND BRAILLE PLASTIC SIGN FIELD CLEAR WINDOW FOR PAPER INSERT BEHIND CE FOR PAPER INSERT PAPER INSERT (BY OWNER) PLASTIC SIGN FIELD /1 / NOTE: NEW SIGN TO MATCH EXISTING BUILDING SIGNAGE. GC TO VERIFY IN FIELD. Interior Room Identification Signage: 1. SUBMIT SHOP DRAWINGS SHOWING SCHEDULE LAYOUT, PROFILES AND PRODUCT COMPONENTS, INCLUDING MATERIAL DETAILS, DIMENSIONS, ANCHORAGE, AND ACCESSORIES FOR ARCHITECT'S REVIEW AND APPROVAL BEFORE STARTING FABRICATION. 2. ALL SIGNAGE SYSTEMS SHALL MEET REQUIREMENTS OF THE AMERICANS WITH DISABILITIES ACT ACCESSIBILITY GUIDELINES (ADAAG) AND LOCAL AMENDMENTS AND MODIFICATIONS. 3. RAISED LETTERING AND/OR NUMERALS: COMPUTER—CUT CHARACTERS WITH MATTE FINISH, COLOR AS SPECIFIED FROM MANUFACTURER'S STANDARD COLOR CHART. SHALL EXTEND A MINIMUM OF 1/32" FROM THE SIGN SURFACE. PHOTOPOLYMER TAGS SHALL NOT BE ACCEPTABLE. / 4. GRADE 2 BRAILLE: CLEAR RASTER BALLS COMPUTER DRILLED AND PRESSURE INSERTED INTO SIGN FACE. SHALL BE HALF—HEMISPHERE IN SHAPE AND SHALL EXTEND A MINIMUM OF 0.025" FROM THE SIGN SURFACE. OTHER METHODS OF MANUFACTURE, INCLUDING SURFACE APPLIED PHOTOPOLYMER BRAILLE TAGS SHALL NOT BE ACCEPTABLE. 5. FASTENER: VERY HIGH BOND (VHB) .030 INCH THICK DOUBLE—FACE TAPE FINISHES COLORS: AS SELECTED FROM THE MANUFACTURER'S STANDARD CHART. PATTERNS: AS SELECTED FROM THE MANUFACTURER'S STANDARD CHART. EE `[OMAN ANTHONY 145 Culver Road Suite 200 Rochester, NY 14620-1678 Telephone 585 427 8888 Facsimile 585 427 8914 ww w. e rdm on antho ny.com Richard McElhiney Architects LLC 347 West 36 St Floor 15 New York, NY 10018 212-245-5195t 212-239-7130 f NOTE: UNAUTHORIZED ALTERATION OR ADDITION TO THIS DRAWING IS A VIOLATION OF THE NEW YORK STATE EDUCATION LAW ARTICLE 145, SECTION 7209. REVISIONS DESCRIPTION DATE ALL RIGHTS RESERVED: NO PART OF THIS DOCUMENT MAY BE REPRODUCED, STORED IN A RETRIEVAL SYSTEM, OR TRANSMITTED, IN ANY FORM OR BY ANY MEANS ELECTRONIC, MECHANICAL, PHOTOCOPYING, RECORDING, OR OTHERWISE WITHOUT THE PRIOR WRITTEN AUTHORIZATION OF ERDMAN ANTHONY. COPYRIGHT © 2019 Erdman Anthony BID DOCUMENTS Z 0 0 z (1! w >- 0 O CO J m M • .. U co M M co 0 0 J J 2 (n 2 co • 1 � >- Z Z D W J Z J W < ZU • Q O I U1— Key Plan: eairiti° DATE: 08.12.2019 PROJECT #: 1001X.29 DRAWN BY: WRK CHECKED BY: RLM SCALE: AS NOTED 3RD FLOOR PLAN, DOOR SCHEDULE, AND DETAILS A-1 01 FIRE PROTECTION ABBREVIATIONS ABOVE ABOVE FINISHED FLOOR ACCESS DOOR ACID RESISTANT WASTE ACID VENT ALARM AQUASTAT ARCHITECT(URAL) ARCHITECT/ENGINEER AREA DRAIN AUTOMATIC AUTOMATIC AIR VENT BACK WATER VALVE BACKFLOW PREVENTER BALANCING VALVE BALL VALVE BATHTUB BELOW BELOW FINISHED FLOOR BRAKE HORSEPOWER BRITISH THERMAL UNIT BRITISH THERMAL UNITS (1000) PER HOUR BRITISH THERMAL UNITS PER HOUR BUILDING BUTTERFLY VALVE BY OWNER CATCH BASIN CHECK VALVE CIRCULATING PUMP CLEAN OUT COLD WATER COMPRESSED AIR COMPRESSOR CONDENSATE DRAIN CONNECTION CONTRACT LIMIT LINE CONTRACTOR CONTROL VALVE CYCLE DECK PLATE CLEAN-OUT DEIONIZED WATER DETAIL DISTILLED WATER DIAMETER DISHWASHER DOWN DRAIN DRAWING DRINKING FOUNTAIN DRY WELL ELECTRIC(AL) ELECTRIC WATER COOLER ELECTRIC WATER HEATER EMERGENCY SHOWER EMERGENCY EYEWASH ENGINEER ENTERING WATER TEMPERATURE EQUIPMENT EXISTING EXPANSION TANK EXTERIOR FACTORY MUTUAL FEET (FOOT) FIRE PROTECTION FLOOR CLEANOUT FLOOR DRAIN FLOOR SINK FLOW SWITCH FULL LOAD AMPS GAGE (GAUGE) GALLON GALLONS PER DAY GALLONS PER HOUR GALLONS PER MINUTE GAS GATE VALVE GREASE TRAP GREASE INTERCEPTOR GENERAL CONTRACTOR HAND SINK HERTZ HIGH PRESSURE GAS HOSE BIBB HORSEPOWER HOT WATER INCH(ES) INCHES WATER COLUMN ABV AFF AD ARW AV ALM AQST ARCH NE ADRN AUTO AAV BWV BFP BAL V BV BT BLW BFF BHP BTU MBH BTU H BLDG BFV BO CB CKVA CP CO CW CA COMP CD CONN CLL CONTR CV CY DPCO DIW DTL DI DIA DWSH DN DR DWG DF DRW ELEC EWC EWH EMSHR EMEW ENGR EWT EQPM (E) ET EXT FM FT FP FCO FD FS FS FLA GA GAL GPD GPH GPM G GV GT GI GC HSNK HZ HPG HB HP HW IN IN WC INDIRECT WASTE INSIDE DIAMETER INSULATION INVERT IRON PIPE SIZE KILOWATT KILOWATT HOUR LAVATORY LEAVING WATER TEMPERATURE LIQUEFIED PERTOLEUM GAS LOCKED ROTOR AMPS MANHOLE MANUFACTURER MATCHLINE MECHANICAL METER MIXING VALVE MINIMUM CIRCUIT AMPACITY MOP SINK MOTOR CONTROL CENTER NATURAL GAS NITROGEN NON -FREEZE HOSE BIBB NORMALLY CLOSED NORMALLY OPEN NOT TO SCALE OUTSIDE DIAMETER OVERFLOW ROOF DRAIN OXYGEN PHASE PLUMBING PNEUMATIC POUNDS PER SQUARE INCH POUNDS PER SQUARE INCH ABSOLUTE POUNDS PER SQUARE INCH GAGE PRESSURE DROP PRESSURE REDUCING VALVE PRESSURE TEMPERATURE RELIEF VALVE PROJECT PUMP PUMP DISCHARGE LINE RAIN WATER LEADER REDUCED PRESSURE ZONE REQUIRED REVOLUTIONS PER MINUTE RISER ROOF DRAIN RUNNING LOAD AMPS SANITARY SANITARY SEWER SCHEDULE SECTION SERVICE SINK SHOWER SINK SLEEVE SPECIFICATIONS SQUARE FOOT SQUARE INCH STAINLESS STEEL STAND PIPE STORAGE TANK STORM DRAIN TEMPERATURE THERMOSTATIC MIXING VALVE TRAP TRAP PRIMER TRENCH DRAIN TYPICAL UNLESS OTHERWISE NOTED UTILITY URINAL VACUUM VACUUM BREAKER VALVE VARIABLE FREQUENCY DRIVE VEMT (SANITARY) VENT TROUGH ROOF VERIFY IN FIELD VOLT WALL HYDRANT WALL CLEAN-OUT WATER CLOSET WATER HAMMER ARRESTOR WATER HEATER WIRE MESH SCREEN IW ID INSUL INV IPS KW KWH LAV LWT LPG LRA MH MFR ML MECH M MV MCA MSNK MCC NG N NFHB NC NO NTS OD ORD OXY PH PLBG PNEU PSI PSIA PSIG PD PRV PTRV PROJ P PD RWL RPZ REQD RPM R RD RLA SAN SS SCHED SECT SS SHR SNK SLV SPEC SQ FT SQ IN SS SP ST ST TEMP TMV T TP TD TYP UON UTIL URN VAC VB V VFD V VTR VIF V WH WCO WC WHA WH WMS cf PIPING SYMBOLS - VALVES AND SPECIALTIES 3 0 BALL VALVE PLUG VALVE SHUT-OFF VALVE IN RISER BALANCING VALVE MIXING VALVE CHECK VALVE ISOLATION VALVE SOLENOID VALVE STRAINER GLOBE VALVE PRESSURE REDUCING VALVE RELIEF VALVE X INDICATES BACKFLOW PREVENTER (BFP) BRANCH CONNECTION - BOTTOM BRANCH CONNECTION - TOP ELBOW TURNED DOWN ELBOW TURNED UP CAP REDUCER 0/-11 CO CLEANOUT (FLOOR/WALL) �+ WH -D WH -FHB -O HB FD T P T PT 11) WHA T AD 0 OR 9 R WALL HYDRANT HOSE BIBB FLOOR DRAIN ROOF DRAIN UNION FLEXIBLE CONNECTOR DIRECTION OF FLOW P - PRESSURE T - TEMPERATURE PT - COMBINATION (PRESS./TEMP.) DIRECTION OF DOWNWARD PITCH PRESSURE/TEMPERATURE TAP PRESSURE GAUGE THERMOMETER CIRCULATING PUMP METER WATER HAMMER ARRESTOR ACCESS DOOR DECK PLATE/YARD CLEAN-OUT POINT OF CONNECTION POINT OF DISCONNECTION EXTENT OF DEMOLITION T FIRE PROTECTION SYMBOLS - VALVES AND SPECIALTIES UPRIGHT SPRINKLER HEAD - 3/4" NPT, 8.0 K, 155° F LISTED INDICATING VALVE WITH TAMPER SWITCH FLOW SWITCH FIRE PROTECTION NOTES A. THE AUTOMATIC SPRINKLER SYSTEMS WITHIN THIS FACILITY SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH NFPA-13. ALL FIRE SUPPRESSION SYSTEMS SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH THE FIRE CODE OF NEW YORK STATE AND CORNELL UNIVERSITY STANDARDS. B. ALL PIPE SIZES AND HYDRAULIC NODES SHOWN ARE FOR REFERENCE ONLY. FIRE PROTECTION CONTRACTOR TO PERFORM HYDRAULIC CALCULATIONS TO DETERMINE FINAL PIPE SIZES. C. THE CONTRACTOR SHALL COORDINATE WITH ALL TRADES AND COMPLY WITH ALL OBSTRUCTION REQUIREMENTS AS DESCRIBED WITHIN NFPA-13. D. THE CONTRACTOR SHALL VISIT THE SITE AND REVIEW EXISTING CONDITIONS AND MAKE ALLOWANCE FOR ANY EXISTING CONDITIONS PRIOR TO SUBMITTING BID. E. ALL COMPONENTS OF AUTOMATIC SPRINKLER SYSTEM SHALL BE LISTED FOR USE IN FIRE SUPPRESSION SYSTEMS AND BE LISTED BY UNDERWRITERS LABORATORIES (UL) AND FM GLOBAL (FM). F. PROVIDE FULL PORT BALL VALVES TO THE END OF ALL BRANCH LINES AND MAIN PIPING TO FACILITATE FUTURE SYSTEM FLUSHING. FLOW TEST INFORMATION A. STATIC PRESSURE: 170 PSI B. RESIDUAL PRESSURE: 150 PSI C. FLOW: 1248 GPM READINGS FROM ANNUAL FIRE PUMP FLOW TEST PERFORMED BY CORNELL UNIVERSITY ON 04/20/18 AT DUFFIELD HALL FIRE PUMP GENERAL NOTES A. THIS LEGEND IS FOR THE CONTRACTOR'S REFERENCE ONLY. NOT ALL SYMBOLS AND/OR ABBREVIATIONS MAY APPLY TO THIS PARTICULAR PROJECT. ANY ADDITIONS OR OMISSIONS FROM THIS LEGEND SHEET DOES NOT IMPLY INCLUSION AND/OR EXCLUSION OF ANY PARTICULAR ITEMS FROM THE PROJECT. B. THE PLANS ARE DIAGRAMMATIC AND INDICATE ONLY THE SIZE AND GENERAL ARRANGEMENT OF PIPING/DUCTWORK AND EQUIPMENT. EXACT LOCATION OF ALL ELEMENTS SHALL BE DETERMINED AS WORK PROGRESSES, IN COOPERATION AND COORDINATION WITH THE WORK OF ALL TRADES. THEY ARE NOT INTENDED TO SHOW EVERY ITEM OF WORK OR MINOR PIECE OF EQUIPMENT. CONTRACTOR SHALL FURNISH AND INSTALL WITHOUT ADDITIONAL REMUNERATION ANY COMPONENT NECESSARY TO COMPLETE THE SYSTEM IN ACCORDANCE WITH THE BEST PRACTICE OF THE TRADE. C. ITEMS OF WORK OR EQUIPMENT SHOWN ON THE DRAWINGS ONLY, OR CALLED FOR IN THE SPECIFICATIONS ONLY, SHALL BE FURNISHED AND INSTALLED IN THE SAME MANNER AS IF THEY APPEARED ON BOTH THE DRAWINGS AND IN THE SPECIFICATIONS. D. DRAWINGS DO NOT INDICATE ALL OFFSETS, CHANGES IN ELEVATIONS, ETC. WHICH MAY BE REQUIRED. THE CONTRACTOR SHALL MAKE SUCH CHANGES IN PIPING/DUCTWORK AND LOCATION OF EQUIPMENT, ETC. TO ACCOMMODATE WORK, OBSTACLES, AND WORK OF OTHER TRADES/CONTRACTORS. E. INSTALL EQUIPMENT AND PIPING/DUCTWORK TO AVOID INTERFERENCE WITH THE OPERATION, SERVICE, AND MAINTENANCE OF EQUIPMENT. F. ALL COSTS FOR CUTTING, PATCHING AND PAINTING OF EXISTING WALLS, CEILINGS AND FLOORS TO ACCOMMODATE THE INSTALLATION OF WORK SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR UNLESS INDICATED OTHERWISE. MATERIALS FOR THE RESTORATION OF EXISTING SURFACES SHALL MATCH THE EXISTING SURFACES. G. PIPES AND/OR DUCTS PENETRATING FIRE WALLS AND FLOORS SHALL BE FIRESTOPPED USING UL APPROVED MATERIALS. REFER TO THE ARCHITECTURAL DRAWINGS FOR FIRE WALL AND FLOOR LOCATIONS. H. ALL PHYSICAL ATTRIBUTES OF EQUIPMENT AND DEVICES ARE BASED ON THOSE MANUFACTURERS LISTED IN THE SPECIFICATIONS AND/OR THE EQUIPMENT SCHEDULES. THE RESPECTIVE CONTRACTORS ARE RESPONSIBLE FOR ALL CHANGES BROUGHT ABOUT BY THE USE OF ITEMS BY OTHER MANUFACTURERS IF THOSE ITEMS DO NOT MATCH THE HYSICAL ATTRIBUTES OF THE MANUFACTURERS LISTED. GENERAL DEMOLITION NOTES A. THE DEMOLITION PLANS AND NOTES HAVE BEEN PREPARED TO ASSIST THE CONTRACTORS IN IDENTIFYING THE AREAS AND ITEMS OF DEMOLITION AND RENOVATION ASSOCIATED WITH THIS PROJECT. THE INFORMATION PROVIDED IS NOT MEANT TO BE ALL-INCLUSIVE IN TERMS OF LISTING EACH AND EVERY SPECIFIC TASK TO BE PERFORMED. EACH CONTRACTOR WILL THOROUGHLY EXAMINE ALL CONTRACT DOCUMENTS PRIOR TO PERFORMING ANY WORK. B. DEMOLITION WORK INCLUDES, BUT IS NOT LIMITED TO, THE ITEMS INDICATED ON THE DEMOLITION DRAWINGS AND DESCRIBED IN THE DEMOLITION NOTES. THE EXTENT OF THE DEMOLITION WORK WILL INCLUDE ALL WORK REQUIRED TO COMPLETE THE PROJECT AND ENSURE WHETHER OR NOT THE WORK IS INDICATED ON THE DRAWINGS. C. EACH CONTRACTOR SHALL THOROUGHLY EXAMINE AND VERIFY ALL EXISTING CONDITIONS BEFORE PERFORMING ANY WORK AND IMMEDIATELY NOTIFY THE OWNER, IN WRITING, OF ANY DISCREPANCIES WITH THE DRAWINGS. D. ALL ITEMS NOTED TO BE REMOVED TO BE DISPOSED OF OFF-SITE BY RESPECTIVE CONTRACTORS, UNLESS NOTED OTHERWISE. WHERE INDICATED ON THE DRAWINGS AND/OR IN THE NOTES AS SALVAGE, THE CONTRACTOR SHALL CAREFULLY REMOVE INDICATED ITEMS AND STORE THEM WHERE DIRECTED BY THE OWNER. E. THE OWNER HAS THE OPTION TO RETAIN POSSESSION OF ANY REMOVED MATERIALS OR EQUIPMENT. ALL SUCH ITEMS SHALL BE CAREFULLY REMOVED AND STORED AT THE SITE BY THE CONTRACTOR WHERE DIRECTED BY THE OWNER. ANY MATERIALS OR EQUIPMENT NOT RETAINED BY THE OWNER WILL BECOME THE PROPERTY OF THE CONTRACTOR AND PROMPTLY REMOVED FROM SITE. F. REFER TO ARCHITECTURAL, ELECTRICAL, AND MECHANICAL DRAWINGS FOR DEMOLITION WORK BY RESPECTIVE CONTRACTORS. EACH CONTRACTOR IS RESPONSIBLE FOR ALL DEMOLITION ASSOCIATED WITH HIS CONTRACT AND SCOPE OF WORK. EACH CONTRACTOR IS RESPONSIBLE TO PATCH AND/OR REPAIR ANY AND ALL CONSTRUCTION AFFECTED BY HIS DEMOLITION. THE EXTENT OF PATCH AND REPAIR SHALL BE AS REQUIRED TO RECEIVE THE SCHEDULED NEW WORK. ALL CONTRACTORS ARE RESPONSIBLE FOR COORDINATION OF WORK WITH OTHER CONTRACTORS BEFORE PERFORMING ANY WORK. G. ALL PATCH AND REPAIR WORK SHALL BE PERFORMED USING MATERIALS THAT MATCH THE EXISTING ADJACENT CONSTRUCTION. WHERE PATCHING EXISTING MASONRY WALLS OR INFILLING BETWEEN WALLS WITH MASONRY TO MATCH EXISTING, "TOOTH -IN" NEW MASONRY TO EXISTING. H. EACH CONTRACTOR IS RESPONSIBLE TO PROTECT ALL EXISTING CONSTRUCTION SCHEDULED TO REMAIN. EACH CONTRACTOR IS RESPONSIBLE TO PATCH AND/OR REPAIR ANY AND ALL CONSTRUCTION AFFECTED BY THEIR DEMOLITION. EACH CONTRACTOR SHALL PATCH (SUBSTRATE AND FINISHED SURFACES) ANY EXISTING FINISHES AFFECTED BY THEIR RESPECTIVE WORK. I. EXISTING CONDITIONS INDICATED ARE OBTAINED FROM AVAILABLE SOURCES (EXISTING DRAWINGS, FIELD SURVEYS, ETC.) AND ARE NOT GUARANTEED TO BE TRUE AND EXACT. CONTRACTOR(S) SHALL FIELD VERIFY EXISTING CONDITIONS AND NOTIFY THE ENGINEER OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH THE AFFECTED PORTION OF THE WORK. J. REMOVAL IN ITS ENTIRETY INCLUDES HANGERS, ELECTRICAL, CONTROLS, ETC., TO LEAVE A LIKE NEW OR MATCHING EXISTING CONDITION. ERDMAN ANTHONY 145 Culver Road Suite 200 Rochester, NY 14620-1678 Telephone 585 427 8888 Facsimile 585 427 8914 www.erdmananthony.com NOTE: UNAUTHORIZED ALTERATION OR ADDITION TO THIS DRAWING IS A VIOLATION OF THE NEW YORK STATE EDUCATION LAW ARTICLE 145, SECTION 7209. REVISIONS DESCRIPTION DATE ALL RIGHTS RESERVED: NO PART OF THIS DOCUMENT MAY BE REPRODUCED, STORED IN A RETRIEVAL SYSTEM, OR TRANSMITTED, IN ANY FORM OR BY ANY MEANS ELECTRONIC, MECHANICAL, PHOTOCOPYING, RECORDING, OR OTHERWISE WITHOUT THE PRIOR WRITTEN AUTHORIZATION OF ERDMAN ANTHONY. COPYRIGHT © 2019 Erdman Anthony BID DOCUMENTS z O O z w >- 0 O CO J CO Mco MMco cn 0 0 O m M J J Z (n 2 C) Lc) co wO z� »- D L J Z W Q ZU • Q O I • I- e91 DATE: 08.12.2019 PROJECT #: 1001X.29 DRAWN BY: LY CHECKED BY: BRW SCALE: AS NOTED DRAWING NOTES FP -000 I -BEAM OR BAR JOIST * SEE NFPA-13 FOR HANGER SIZE AND SPACING ALL THREAD ROD AUTO GRIP 1 TOP BEAM CLAMP HANGER 1 Scale: NTS 2 NIT HEATER ZONE DETAIL Scale: NTS INTERMEDIATE TEMPERATURE SPRINKLER HEADS I -BEAM OR -7.- BAR JOIST _BEAM CLAMP _BALL THREAD ROD * SEE NFPA-13 FOR HANGER SIZE AND SPACING AUTO GRIP ■ AUTO GRIP PIPE 3 TRAPEEZE HANGER Scale: NTS GALV. AUTO GRIP SUPPORT FROM JOIST OR DECK ABOVE _ 1" MIN./12" MAX. UNDERSIDE OF CEILING UPRIGHT SPRINKLER REDUCER PIPE NIPPLE BRANCH LINE * ALL OUTLETS IN BRANCH PIPING SHOULD BE A MIN. OF 1" TO ALLOW FOR FUTURE REVISIONS. 4 TYPICAL UPRIGHT SPRINKLER HEAD DETAIL Scale: NTS ERDMAN ANTHONY 145 Culver Road Suite 200 Rochester, NY 14620-1678 Telephone 585 427 8888 Facsimile 585 427 8914 www.erdmananthony.com NOTE: UNAUTHORIZED ALTERATION OR ADDITION TO THIS DRAWING IS A VIOLATION OF THE NEW YORK STATE EDUCATION LAW ARTICLE 145, SECTION 7209. REVISIONS DESCRIPTION DATE ALL RIGHTS RESERVED: NO PART OF THIS DOCUMENT MAY BE REPRODUCED, STORED IN A RETRIEVAL SYSTEM, OR TRANSMITTED, IN ANY FORM OR BY ANY MEANS ELECTRONIC, MECHANICAL, PHOTOCOPYING, RECORDING, OR OTHERWISE WITHOUT THE PRIOR WRITTEN AUTHORIZATION OF ERDMAN ANTHONY. COPYRIGHT © 2019 Erdman Anthony BID DOCUMENTS z O O z w >- 0 O CO J CO • O M C.) coM oo cn 0 0 M m M M J J Z (n 2 C) U) co wO »- z Dw J Z w < ZU • Q O I • I— e91 DATE: 08.12.2019 PROJECT #: 1001X.29 DRAWN BY: LY CHECKED BY: BRW SCALE: AS NOTED FIRE PROTECTION DETAILS FP -500 IENLARGED FIRE ALARM - DEMOLITION PLAN Scale: 1/4" = 11-0" ENLARGED FIRE ALARM - NEW WORK PLAN 4. Scale: 1/4" = 11-0" KEYED NOTES: 1. PROVIDE FIRE ALARM VISUAL NOTIFICATION DEVICE AND CONNECT TO NEAREST FIRE ALARM NOTIFICATION CIRCUIT. ERDMAN ANTHONY 145 Culver Road Suite 200 Rochester, NY 14620-1678 Telephone 585 427 8888 Facsimile 585 427 8914 www.erdmananthony.com NOTE: UNAUTHORIZED ALTERATION OR ADDITION TO THIS DRAWING IS A VIOLATION OF THE NEW YORK STATE EDUCATION LAW ARTICLE 145, SECTION 7209. REVISIONS DESCRIPTION DATE ALL RIGHTS RESERVED: NO PART OF THIS DOCUMENT MAY BE REPRODUCED, STORED IN A RETRIEVAL SYSTEM, OR TRANSMITTED, IN ANY FORM OR BY ANY MEANS ELECTRONIC, MECHANICAL, PHOTOCOPYING, RECORDING, OR OTHERWISE WITHOUT THE PRIOR WRITTEN AUTHORIZATION OF ERDMAN ANTHONY. COPYRIGHT © 2019 Erdman Anthony BID DOCUMENTS z O O z w >- 0 O CO J CO • O M C.) coM oo cn 0 0 M m M J J Z (n 2 C) U) co wO »- z Dw J Z W Q ZU • Q O I • I— e91 DATE: 08.12.2019 PROJECT #: 1001X.29 DRAWN BY: DU CHECKED BY: BRW SCALE: AS NOTED ENLARGED FIRE ALARM PLANS FA -100 INDICATES VERTICAL DROP GENERAL DUPLEX RECEPTACLE, NEMA 5-20R, 18" AFF TO CENTER U01 # - CIRCUIT NUMBER OC - MOUNT VERTICALLY 6" ABOVE COUNTERTOP OR SINK BC - MOUNT BELOW COUNTERTOP OR SINK P - PENDANT MOUNTED GFI - GROUND FAULT INTERRUPTING SB - INDICATES STANDBY POWER, RED COLOR SBX - SMART BOX RECEPTACLE - MOUNT CENTER OF RECEPTACLE AT 46"AFF SMART BOX PROVIDED BY OWNER SMB - SMART BOARD RECEPTACLE - MOUNT ABOVE SMART BOARD PROVIDED BY OWNER A TV - TV/MONITOR RECEPTACLE IN MULTI -SERVICE RECESSED 2 -GANG WALL BOX MOUNT CENTER OF RECESSED WALL BOX AT 6'-8" AFF WP - WEATHERPROOF COVER A A in A FLFCTRICAL SYV SOL DIST AOa a A H A V a A a Il 1 4 DOUBLE DUPLEX RECEPTACLE, 18" AFF TO CENTER UOI, SUBSCRIPTS TO MATCH DUPLEX RECEPTACLE IIP F DUPLEX RECEPTACLE, NEMA 5-20R, MOUNTED IN FLOOR BOX DIVIDED SURFACE MOUNTED RACEWAY W/RECEPTACLES BELOW AND TELECOMMUNICATION OUTLETS ABOVE. REFER TO FLOOR PLANS & ARCHITECTURAL ELEVATIONS FOR MOUNTING HEIGHTS. RCR RETRACTABLE CORD REEL, CEILING MOUNT, w/NEMA 5-20R WATERPROOF DOUBLE DUPLEX RECEPTACLE # SPECIAL PURPOSE RECEPTACLE # - NEMA SIZE SINGLE POLE WALL SWITCH, 120/277V, 20A, 48" AFF TO CENTER U01 LOWER CASE LETTER INDICATES SWITCHING ARRANGEMENT FIRST NUMBER INDICATES QUANTITY OF SWITCHES AT LOCATION SHOWN SECOND NUMBER/LETTER INDICATES: 2 - TWO POLE 3 - THREE WAY 4 - FOUR WAY CMB - CORRIDOR MAINTENANCE BY-PASS SWITCH, MOUNT 6'-0"AFF MC - MOMENTARY CONTACT VD - VACANCY SENSOR SWITCH WITH INTEGRAL DIMMER D - DIMMER R - SPDT SW FOR RED LAMPS (ON/OFF) T - TIMER, 208-277V, 20A, SPST TWHT - TIMER, 208-277V, 20A, SPST (FOR WHITE LAMPS ONLY) WP - WATERPROOF COVER $2a 2D AC V DATA OUTLET LOCATION, 18"AFF U01 #D - NUMBER INDICATES QUANTITY OF DATA OUTLETS AT THIS LOCATION (I.E. 2D = TWO (2) DATA OUTLETS) AC - MOUNT HORIZONTALLY 6" ABOVE COUNTER TOP C - CEILING MOUNT F - FLOOR MOUNTED PROJ - PROJECTOR WT - WATER TIGHT SBX - SMART BOX DATA DROP - MOUNT CENTER OF BOX AT 46"AFF TV - TV/MONITOR DATA DROP IN MULTI -SERVICE RECESSED 2 -GANG WALL BOX MOUNT CENTER OF RECESSED WALL BOX AT 6'-8" AFF ®# EQUIPMENT CONNECTION, #=EQUIPMENT NUMBER, REFER TO EQUIPMENT AND CONTROL SCHEDULE 0-# MOTOR CONNECTION, #=EQUIPMENT NUMBER, REFER TO 1 -LINE DIAGRAM AND MECHANICAL SCHEDULE DRAWING El AUTO DOOR PUSH PLATE SWITCH, FURNISH AND INSTALL FLUSH MTD BOX & CONDUIT TO DOOR CONTROLLER, COORDINATE LOCATION WITH ARCHITECTURAL DRAWINGS T J VAV BOX CLASS 2 AC TRANSFORMER, 100VA, 120VAC PRI.-24VAC SEC. MOUNT TO JBOX ABOVE SUSPENDED CEILING $M SPST SNAP SWITCH FOR VAV BOX XFMR, 1P, 20A, 125VAC MTD ABOVE CEILING AT VAV XFMR ❑J QJ 3R 30❑J 15�J 30 #® #EEP ® VARIABLE FREQUENCY CONTROLLER WAP WIRELESS ACCESS POINT DIDF DATA INTERMEDIATE DISTRIBUTION FRAME El EMERGENCY LIGHTING RELAY HP -01 JUNCTION BOX SB - STANDBY POWER JUNCTION BOX F - FLOOR BOX, CAST IRON WITH ADJUSTABLE BRASS COVER, ROUGH -IN SLAB WP - WEATHERPROOF DISCONNECT SWITCH, #=AMPERE RATING, VOLTAGE RATING TO MATCH CIRCUIT NEMA 3R FUSED DISCONNECT SWITCH, VOLTAGE RATING TO MATCH CIRCUIT, #=FUSE/DISCONNECT AMPERE RATING PM - ELEVATOR POWER MODULE SWITCH, FUSIBLE, WITH SHUNT TRIP MAGNETIC MOTOR STARTER, # = NEMA SIZE COMBINATION DISCONNECT MAGNETIC MOTOR STARTER, # = NEMA SIZE VS TMR ❑H 0 DETAIL DESIGNATION PANELBOARD. REFER TO PANELBOARD SCHEDULE CABLE TRAY VIBRATION SWITCH SUPPLIED WITH COOLING TOWER TIMER, ADJUSTABLE 0-60 MINUTES ELECTRIC HAND/HAIR DRYER, 120VAC, MOUNT 45"AFF TO BOTTOM THERMOSTAT, SUPPLIED WITH UNIT, INSTALLED UNDER THIS CONTRACT GROUND CONNECTION ELECTRIC CIRCUIT, SHORT HASH=PHASE CONDUCTOR, LONG HASH=GROUNDED CIRCUIT CONDUCTOR I INDICATES GROUND CONDUCTOR, SIZE AS NOTED HOMERUN TO INDICATED PANELBOARD, #'S=CIRCUIT NUMBERS, # ARROWS=# OF CIRCUITS UNDER GROUND/ IN FLOOR OR CONCEALED CONDUIT VAV LV TRANSFORMER WIRING ej 6 FT LONG COILED IN PLACE WIFI CABLING (WIFI UNIT FURNISHED AND INSTALLED BY OWNER) ® FEEDER DESIGNATION NOTE REFERENCE NUMBER, SEE INDICATED NOTE # INDICATES DEVICE/EQUIPMENT IS EXISTING / R\ REVISION NUMBER SHEET REFERENCE DETAIL REFERENCE CR HARDWIRED CARD READER LOCATION. REFER TO DETAIL 2/E-700 FOR SCOPE OF WORK. (E) EXISTING TO REMAIN. • eiN CLASS 2 WIRING (24VAC) A A A a A A A LIGHTING a LUMINAIRES UPPER CASE LETTER = LUMINAIRE TYPE, SEE LUMINAIRE SCHEDULE, a LOWER CASE LETTER = SWITCHING ARRANGEMENT LUMINAIRE CONNECTED TO EMERGENCY CIRCUIT UPPER CASE LETTER = LUMINAIRE TYPE, SEE LUMINAIRE SCHEDULE, LOWER CASE LETTER = SWITCHING ARRANGEMENT EXIT SIGN W/INTEGRAL BATTERY, ARROW INDICATES ARROW DIRECTION AND FACE CEILING MOUNTED WALL MOUNTED, 7'-6" AFF 1=1 OCCUPANCY SENSOR - SWITCHPACK AUX CONTACT REQUIRED FOR HVAC CONTROL CS V CS H DS VACANCY SENSOR - CEILING MOUNTED AUX CONTACT REQUIRED FOR HVAC CONTROL HALLWAY OCCUPANCY SENSOR - CEILING MOUNTED AUX CONTACT REQUIRED FOR HVAC CONTROL ONLY (NO LTG CTRL) LIGHTING DAYLIGHT SENSOR FIRE ALARM © FIRE ALARM - MANUAL PULL STATION, 48" AFF TO TOP ❑Q FIRE ALARM - INDICATING AUDIO, 90" AFF TO TOP I1 FIRE ALARM - INDICATING AUDIO/VISUAL, 90"AFF TO TOP ®# 10# ACM FAC P NAC # - INDICATES CANDELLA RATING FIRE ALARM - INDICATING VISUAL, 90" AFF TO TOP # - INDICATES CANDELLA RATING FIRE ALARM - HEAT DETECTOR, COMBINATION U01 # - SET TEMP. TYPE, # INDCATES TEMP. RATING FIRE ALARM - SMOKE DETECTOR, PHOTOELECTRIC TYPE I - IONIZATION TYPE A - UNIT WITH AUXILIARY CONTACT FIRE ALARM - ADDRESSIBLE CONTROL MODULE FIRE ALARM - FIRE ALARM CONTROL PANEL FIRE ALARM - FIRE ALARM ANNUNCIATOR PANEL FIRE ALARM - NOTIFICATION APPLIANCE CIRCUIT PANEL FIRE ALARM - FIRE ALARM - FIRE ALARM - FIRE ALARM - FIRE ALARM - A AC AIC AFF AFG ATS AWG C CB CF CLG CKT CCTV CP CT CU DISC DF EC EMT EM EX XP F FA FAC P FAAP FBO G GFI HP HPS JB kVAR kVA ADDRESSABLE MODULE TAMPER SWITCH CONNECTION FLOW SWITCH CONNECTION PRESSURE SWITCH SMOKE DAMPER ABBREVIATIONS AMPERE(S) ALTERNATING CURRENT AMPERE INTERRUPTING CAPACITY ABOVE FINISHED FLOOR ABOVE FINISHED GRADE AUTOMATIC TRANSFER SWITCH AMERICAN WIRE GAUGE CONDUIT CIRCUIT BREAKER COMPACT FLUORESCENT CEILING CIRCUIT CLOSED CIRCUIT TELEVISION CONTROL PANEL CURRENT TRANSFORMER COPPER DISCONNECT DRINKING FOUNTAIN ELECTRICAL CONTRACTOR ELECTRICAL METALLIC TUBING EMERGENCY EXISTING EXPLOSION PROOF FUSE FIRE ALARM FIRE ALARM CONTROL PANEL FIRE ALARM ANNUNCIATOR PANEL FURNISHED BY OTHERS GROUND GROUND FAULT INTERRUPTER HORSEPOWER HIGH PRESSURE SODIUM JUNCTION BOX KILOVAR(S) KILOVOLT AMPERE(S) kW MCB MCC MH MNH MLO NEC NC NCHO NO NTS OL P PC PF PT PVC RECP RMC SMR ST SWBD TV TVSS TYP UH U01 UPS V VA VFD W WP ONE LINE CURRENT TRANSFORMER, #- RATIO E- POTENTIAL TRANSFORMER, #- RATIO HH A I ®# —0 o- 0 O 0 ❑S 0 0 —0 0—I I1 o\ o KILOWATT(S) MAIN CIRCUIT BREAKER MOTOR CONTROL CENTER METAL HALIDE MANHOLE MAIN LUGS ONLY NATIONAL ELECTRIC CODE NORMALLY CLOSED NORMALLY CLOSED HELD OPEN NORMALLY OPEN NOT TO SCALE OVER LOAD POLE PHOTOCELL POWER FACTOR POTENTIAL TRANSFORMER POLYVINYL CHLORIDE RECEPTACLE RIGID METALLIC CONDUIT SURFACE METAL RACEWAY SHUNT TRIP SWITCHBOARD TELEVISION TRANSIENT VOLTAGE SURGE SUPPRESSER TYPICAL UNIT HEATER UNLESS OTHERWISE INDICATED UNINTERRUPTIBLE POWER SUPPLY VOLT(S) VOLTAMP(S) VARIABLE FREQUENCY DRIVE WATT(S) EQUIPMENT/MATERIAL TO BE WEATHERPROOF TYPE CONTACT - NORMALLY OPEN CONTACT - NORMALLY CLOSED CONTROL RELAY, #=REFERENCE NUMBER AIR CIRCUIT BREAKER, RATINGS AS INDICATED, 3 POLE U01 SS - SOLID STATE TRIP L - ADJUSTABLE LONG TIME SETTINGS S - ADJUSTABLE SHORT TIME SETTINGS I - ADJUSTABLE INSTANTANEOUS SETTINGS G - ADJUSTABLE GROUND FAULT AND DELAY SETTINGS START/STOP PUSHBUTTON DRAW OUT DEVICE FUSE DISCONNECT SWITCH TRANSFORMER AMMETER POWER FACTOR METER SYNCHROSCOPE VOLTMETER SELECTOR SWITCH WATTHOUR/DEMAND METER PROTECTIVE RELAY, #=ANSI DESIGNATION NUMBER LIGHTNING ARRESTOR TRANSFER SWITCH OVERLOADS GENERAL NOTES: 1. CONTRACTORS ARE URGED TO INSPECT THE SITE BEFORE SUBMITTING A BID PROPOSAL TO ENSURE KNOWLEDGE OF PROJECT REQUIREMENTS AND SITE CONDITIONS. IF NO CLARIFICATION IS REQUESTED, IT WILL BE CONSIDERED THAT THE CONTRACTORS ARE IN FULL UNDERSTANDING OF PROJECT REQUIREMENTS. 2. PROVIDE LABOR, SUPERVISION, EQUIPMENT, MATERIALS, CONSTRUCTION TOOLS, TRANSPORTATION, INSURANCE AND SERVICES REQUIRED FOR THE COMPLETE INSTALLATION OF THIS WORK IN ACCORDANCE WITH APPLICABLE FEDERAL, STATE, AND LOCAL CODES, AUTHORITIES HAVING JURISDICTION, AND STANDARDS INCLUDING BUT NOT LIMITED TO, ASHRAE, IBC, NEC, AND NFPA. 3. NOTHING CONTAINED IN THE SPECIFICATIONS OR SHOWN ON THE DRAWINGS SHALL BE CONSTRUED TO BE IN CONFLICT WITH ANY STATE OR LOCAL CODES, ORDINANCES OR REGULATIONS. 4. THE USE OF THE WORD "PROVIDE" SHALL MEAN TO FURNISH, INSTALL AND CONNECT, READY TO USE. 5. THE USE OF THE WORD "FURNISH" SHALL MEAN TO PROCURE AND DELIVER TO THE SITE. 6. THE USE OF THE WORD "INSTALL" SHALL MEAN TO PHYSICALLY PLACE INTO SERVICE AND CONNECT, READY TO USE. 7. EQUIPMENT AND MATERIALS SHALL BE INSTALLED BY SKILLED TRADESMEN, FAMILIAR WITH THE COMPONENTS TO BE INSTALLED, AND IN ACCORDANCE WITH BEST PRACTICES OF THE INDUSTRY. 8. BECAUSE OF THE SMALL SCALE OF THE DRAWINGS, IT IS NOT POSSIBLE TO INDICATE ALL OFFSETS, FITTINGS, AND ACCESSORIES THAT MAY BE REQUIRED. THIS CONTRACTOR SHALL CAREFULLY EXAMINE THE ARCHITECTURAL; STRUCTURAL; HEATING, VENTILATING AND AIR-CONDITIONING; ELECTRICAL; PLUMBING; AND OTHER PROJECT DOCUMENTS AS MAY BE NECESSARY FOR PROPER OPERATION OR INSTALLATION AND SHALL PROVIDE OFFSETS, FITTINGS, AND ACCESSORIES TO MEET PROJECT CONDITIONS. 9. DISCREPANCIES BETWEEN DRAWINGS OR BETWEEN DRAWINGS AND SPECIFICATIONS SHALL BE REPORTED TO PROFESSIONAL IN WRITING. OBTAIN WRITTEN INSTRUCTIONS FROM PROFESSIONAL AS TO THE MANNER IN WHICH TO PROCEED. NO DEPARTURES FROM THE PROJECT DOCUMENTS SHALL BE MADE WITHOUT PRIOR WRITTEN ACCEPTANCE OF THE PROFESSIONAL. 10. DIMENSIONS, CLEARANCES, AND LOCATIONS OF EQUIPMENT AND MATERIALS SHALL BE FIELD VERIFIED PRIOR TO ORDERING, PROCURING AND FURNISHING SAME. 11. NO EXTRA COMPENSATION OR CHARGES WILL BE ACCEPTED DUE TO DIFFERENCES BETWEEN THE ACTUAL MEASUREMENTS AND THOSE INDICATED ON THE PLAN. THOROUGHLY COORDINATE WORK WITH SITE CONDITIONS AND OTHER TRADES, DETERMINE EXACT ROUTE AND LOCATION OF EACH DUCT, PIPE, CONDUIT, ETC. BEFORE FABRICATION AND INSTALLATION. 12. INSTALL WORK SUBSTANTIALLY AS INDICATED. VERIFY LOCATIONS AND ELEVATIONS ON JOB SITE; DO NOT DIRECTLY SCALE DRAWINGS. MAKE NECESSARY CHANGES IN ELEVATION, FITTINGS, OR OFFSETS TO ACCOMMODATE OBSTACLES OR INTERFERENCES. 13. CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR DAMAGE TO THE BUILDING, PIPING OR EQUIPMENT THAT IS THE RESULT OF WORK FOR INSTALLATION OF THIS CONTRACT. 14. THE INSTALLING CONTRACTOR IS RESPONSIBLE FOR PATCH AND REPAIR OF ALL SURFACES TO MATCH EXISTING MATERIALS AND ADJACENT FINISHES ASSOCIATED WITH INSTALLATION/REMOVAL OF THIS WORK. 15. WORK SHALL BE COMPLETED TO MAINTAIN ALL NECESSARY AND REQUIRED CLEARANCES, ACCESSES, AND OPENINGS, SUCH THAT FULL FUNCTIONALITY, PROPER OPERATION, AND REPAIR AND MAINTENANCE ARE ENSURED. 16. WHERE DEVICE HEIGHT OF 48" OCCURS AT POINT OF CHANGE OF FINISH, THE DEVICE SHALL BE RAISED OR LOWERED TO OCCUR IN ONE FINISH. 17. WHERE DEVICE OCCURS IN BRICK, TILE, OR BLOCK WALLS, THEY SHALL BE MOUNTED AT A VERTICAL MASONRY JOINT & IN EITHER THE TOP OR BOTTOM HORIZONTAL JOINT, CLOSEST TO THE MOUNTING HEIGHT. 18. UNLESS OTHERWISE NOTED, ALL MOUNTING HEIGHT DIMENSIONS LISTED ARE TO THE CENTER LINE OF THE WALL BOX OR DEVICE. 19. NOT ALL ABBREVIATIONS & SYMBOLS MAY APPLY TO THIS PROJECT. 20. ALL ELECTRICAL MATERIALS, DEVICES, APPLIANCES, AND EQUIPMENT SHALL BE LABELED AND LISTED BY A CERTIFIED TESTING LABORATORY OR AGENCY. 21. DRAWINGS REPRESENT THE SCOPE OF WORK IN GENERAL ARRANGEMENT FORM AND ARE INTENDED TO SHOW GENERAL ROUTING AND REQUIRED SIZES/CAPACITIES OF SYSTEM COMPONENTS. EXACT ROUTING OF CONDUITS AND CABLES SHALL BE DETERMINED BY JOB SITE SURVEY. 22. ALL CIRCUITS SHALL BE (2) #12 AWG AND (1) #12 AWG GROUND IN 3/4" CONDUIT FROM A 20A, SINGLE POLE CIRCUIT BREAKER UNLESS OTHERWISE INDICATED. PROVIDE A GROUNDING CIRCUIT CONDUCTOR SIZED IN ACCORDANCE WITH THE N.E.C. WITH EACH CIRCUIT. 23. WHERE STANDBY POWER AND NORMAL POWER ARE IN THE SAME CONDUIT OR SURFACE MOUNTED RACEWAY, THE NEUTRAL CONDUCTOR FOR THE STANDBY POWER CIRCUIT IS TO BE PER N.E.C. 200.6D. 24. EMERGENCY CIRCUITS AND NORMAL CIRCUITS CAN NOT BE IN THE SAME CONDUIT. PROVIDE SEPERATE CONDUITS FOR EMERGENCY CIRCUITS. ERDMAN ANTHONY 145 Culver Road Suite 200 Rochester, NY 14620-1678 Telephone 585 427 8888 Facsimile 585 427 8914 www.erdmananthony.com NOTE: UNAUTHORIZED ALTERATION OR ADDITION TO THIS DRAWING IS A VIOLATION OF THE NEW YORK STATE EDUCATION LAW ARTICLE 145, SECTION 7209. REVISIONS DESCRIPTION DATE ALL RIGHTS RESERVED: NO PART OF THIS DOCUMENT MAY BE REPRODUCED, STORED IN A RETRIEVAL SYSTEM, OR TRANSMITTED, IN ANY FORM OR BY ANY MEANS ELECTRONIC, MECHANICAL, PHOTOCOPYING, RECORDING, OR OTHERWISE WITHOUT THE PRIOR WRITTEN AUTHORIZATION OF ERDMAN ANTHONY. COPYRIGHT © 2019 Erdman Anthony BID DOCUMENTS z O O z w >- O O CO J CO O O M CO Mco cn 0 0 M m M M J J Z (n 2 e91 DATE: 08.12.2019 PROJECT #: 1001X.29 DRAWN BY: DU CHECKED BY: BRW SCALE: AS NOTED GENERAL NOTES & SYMBOLS E-000 CORNELL UNIVERSITY Phillips Hall Rooms 338B; 338C; 300UB Laboratory Renovation SELF PRICING BID ADDENDUM NO. ONE September 19, 2019 This Addendum contains changes to the requirements of the Contract Documents and Specifications. Such changes are to be incorporated into the Construction Documents and shall apply to the work with the same meaning and force as if they had been included in the original document. Wherever this Addendum modifies a portion of a paragraph of the specifications or a portion of any Drawing, the remainder of the Paragraph or Drawing shall remain in force. NOTE: Provisions of all Contract Documents apply. Item 1. Revision Bulletin – No. RB-01 issued by Erdman Anthony September 19, 2019 Revision Bulletin – No. RB-01 Phillips Hall – Room 333B, 338C & 300UB Renovation Addendum No. RB-01 September 19, 2019 Page 1 of 2 September 19, 2019 Revision Bulletin: BA-01 Project Name: Phillips Hall Rooms 338B; 338C; 300UB Laboratory Renovation e-Builder Project No.: 11106 Engineer: Erdman Anthony – Andrew Taylor ASI - Clarification PR -Change in Scope REASON: Pre-Bid revision per Review Comments, RFI and Pre-Bid site walkthrough questions. DESCRIPTION: TO THE DRAWINGS: 1. DRAWING EP-100: a. ADDED Keyed Note 10. b. ADDED Demolition Keyed Note D8. c. REVISED Demolition Keyed Note D4. d. REVISED General Note G1. e. ADDED Demolition Keyed Note D8 to existing door entering Room 338B; Detail 1. f. ADDED Keyed Note 5 to both single compartment raceway descriptions in Room 33B; Detail 2. g. REVISED location of emergency shutdown pushbutton due to door swing reversal; Detail 2. h. ADDED door hardware power supply connection and Keyed Note 10 to new door entering Room 338B; Detail 2. 2. DRAWING EL-100: a. REVISED locations of new dimmer switches in Room 338B due to door swing reversal; Detail 2. 3. DRAWING ET-100: a. REVISED General Note G1. b. ADDED Keyed Note D1 to existing data outlets in Room 330B and Room 338C; Detail 2. 4. DRAWING E-700: a. ADDED Detail 3, “Typical Card Access @ Interior Doors”. b. REVISED Panelboard Schedule for PP-338B. 5. DRAWING M-100: a. REVISED Keyed Notes. b. ADDED existing window image. Revision Bulletin – No. RB-01 Phillips Hall – Room 333B, 338C & 300UB Renovation Addendum No. RB-01 September 19, 2019 Page 2 of 2 6. DRAWING FP-100: a. ADDED pendent sprinkler heads to corridor 300CC b. REVISED Keyed Notes TO THE SPECIFICATIONS: 1. Refer to attached Specification Section 271500 – Communications Horizontal Cabling for changes. CORNELL UNIVERSITY Phillips Hall Room 333B, 338C & 300UB Renovation Project 27 15 00 - 1 COMMUNICATIONS HORIZONTAL CABLING ERDMAN ANTHONY Project No. 1001X.29 N:\1001X-29-PhillipsHall\Records\Construction\Field Directive\RB-01\271500 - COMMUNICATIONS HORIZONTAL CABLING RB-01.docN:\1001X-29-PhillipsHall\ContentFac\Specifications\271500 - COMMUNICATIONS HORIZONTAL CABLING.DOC9/19/20199/18/2019 9/19/20199/18/2019 SECTION 271500 - COMMUNICATIONS HORIZONTAL CABLING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section. B. Cornell University Design and Construction Standards 270000 Communications 1.2 SUMMARY A. Section Includes: 1. UTP cabling. 2. Multiuser telecommunications outlet assemblies. 3. Telecommunications outlet/connectors. 4. Cabling system identification products. B. Related Requirements: 1. Section 271501.11 "Conductors and Cables for Electronic Safety and Security" for voice and data cabling associated with system panels and devices. 1.3 DEFINITIONS A. BICSI: Building Industry Consulting Service International. B. Consolidation Point: A location for interconnection between horizontal cables extending from building pathways and horizontal cables extending into furniture pathways. C. Cross-Connect: A facility enabling the termination of cable elements and their interconnection or cross-connection. D. EMI: Electromagnetic interference. E. IDC: Insulation displacement connector. F. LAN: Local area network. G. MUTOA: Multiuser telecommunications outlet assembly, a grouping in one location of several telecommunications outlet/connectors. CORNELL UNIVERSITY Phillips Hall Room 333B, 338C & 300UB Renovation Project 27 15 00 - 2 COMMUNICATIONS HORIZONTAL CABLING ERDMAN ANTHONY Project No. 1001X.29 N:\1001X-29-PhillipsHall\Records\Construction\Field Directive\RB-01\271500 - COMMUNICATIONS HORIZONTAL CABLING RB-01.docN:\1001X-29-PhillipsHall\ContentFac\Specifications\271500 - COMMUNICATIONS HORIZONTAL CABLING.DOC9/19/20199/18/2019 9/19/20199/18/2019 H. Outlet/Connectors: A connecting device in the work area on which horizontal cable or outlet cable terminates. I. RCDD: Registered Communications Distribution Designer. J. UTP: Unshielded twisted pair. 1.4 ADMINISTRATIVE REQUIREMENTS A. Coordinate layout and installation of telecommunications cabling with Owner's telecommunications and LAN equipment and service suppliers. B. Coordinate telecommunications outlet/connector locations with location of power receptacles at each work area. 1.5 ACTION SUBMITTALS A. Product Data: For each type of product. 1.6 INFORMATIONAL SUBMITTALS A. Qualification Data: For Installer, qualified layout technician, installation supervisor, and field inspector. B. Field quality-control reports. 1.7 PRIOR TO CLOSEOUT SUBMITTALS A. A cable schedule in MS Excel format identifying TR room number, racks, patch panels and IT outlet designations. 1.8 CLOSEOUT SUBMITTALS A. Record drawings with as-built notations showing telecomm rooms (TR), major pathways, pullboxes, and outlet designations. B. A copy of the AutoCAD and MS Excel files listed above delivered on CD. C. Cable manufacturer’s warranty naming CIT/Infrastructure Engineering as the Owner. CORNELL UNIVERSITY Phillips Hall Room 333B, 338C & 300UB Renovation Project 27 15 00 - 3 COMMUNICATIONS HORIZONTAL CABLING ERDMAN ANTHONY Project No. 1001X.29 N:\1001X-29-PhillipsHall\Records\Construction\Field Directive\RB-01\271500 - COMMUNICATIONS HORIZONTAL CABLING RB-01.docN:\1001X-29-PhillipsHall\ContentFac\Specifications\271500 - COMMUNICATIONS HORIZONTAL CABLING.DOC9/19/20199/18/2019 9/19/20199/18/2019 1.9 QUALITY ASSURANCE A. Installer Qualifications: Cabling Installer must have personnel on staff certified by BICSI and/or Panduit. 1. Layout Responsibility: Preparation of Shop Drawings and Cabling Administration Drawings 2. Installation Supervision: Installation shall be under the direct supervision of Registered Technician, who shall be present at all times when Work of this Section is performed at Project site. 3. Testing Supervisor: Currently certified by BICSI to supervise on-site testing. B. Testing Agency Qualifications: An NRTL. 1. Testing Agency's Field Supervisor: Currently certified by BICSI to supervise on-site testing. PART 2 - PRODUCTS 2.1 HORIZONTAL CABLING DESCRIPTION A. Horizontal cable and its connecting hardware provide the means of transporting signals between the telecommunications outlet/connector and the horizontal cross-connect located in the communications equipment room. This cabling and its connecting hardware are called a "basic link," a term that is used in the testing protocols. B. Bridged taps and splices shall not be installed in the horizontal cabling. C. The maximum allowable horizontal cable length is 295 feet (90 m). This maximum allowable length does not include an allowance for the length of 16 feet (4.9 m) to the workstation equipment or in the horizontal cross-connect. 2.2 PERFORMANCE REQUIREMENTS A. General Performance: Horizontal cabling system shall comply with transmission standards in TIA/EIA-568-C when tested according to test procedures of this standard. B. Surface-Burning Characteristics: Comply with ASTM E 84; testing by a qualified testing agency. Identify products with appropriate markings of applicable testing agency. 1. Flame-Spread Index: 25 or less. 2. Smoke-Developed Index: 50 or less. C. Electrical Components, Devices, and Accessories: Listed and labeled as defined in NFPA 70, by a qualified testing agency, and marked for intended location and application. CORNELL UNIVERSITY Phillips Hall Room 333B, 338C & 300UB Renovation Project 27 15 00 - 4 COMMUNICATIONS HORIZONTAL CABLING ERDMAN ANTHONY Project No. 1001X.29 N:\1001X-29-PhillipsHall\Records\Construction\Field Directive\RB-01\271500 - COMMUNICATIONS HORIZONTAL CABLING RB-01.docN:\1001X-29-PhillipsHall\ContentFac\Specifications\271500 - COMMUNICATIONS HORIZONTAL CABLING.DOC9/19/20199/18/2019 9/19/20199/18/2019 D. Grounding: Comply with J-STD-607-A. 2.3 UTP CABLE A. Manufacturers: Subject to compliance with requirements, provide products by one of the following: 1. Berk-Tek; a Nexans company. 2. SYSTIMAX Solutions; a CommScope Inc. brand. 3. Panduit GenSPEED 4. Superior Essex B. Description: 100-ohm, four-pair UTP, covered with a thermoplastic jacket. 1. Comply with ICEA S-90-661 for mechanical properties. 2. Comply with TIA/EIA-568-C for performance specifications. 3. Comply with TIA/EIA-568-C Category 6 and Category 6A. 4. Listed and labeled by an NRTL acceptable to authorities having jurisdiction as complying with UL 444 and NFPA 70 for the following types: a. Communications, General Purpose: Type CM or CMG. b. Communications, Plenum Rated: Type CMP, complying with NFPA 262. C. Category 6 UTP (Blue): CommScope-Systimax 1071E, Berk Tek Lanmark 1000, Panduit GenSPEED 6000, Superior Essex DataGain 6+. D. Category 6A UTP (Green): CommScope-Systimax 1091B, Berk Tek Lanmark 10G2. 2.4 UTP CABLE HARDWARE A. Manufacturers: Substitutions are not allowed. 1. Panduit Corp. B. General Requirements for Cable Connecting Hardware: Comply with TIA/EIA-568-C, IDC type, with modules designed for punch-down caps or tools. Cables shall be terminated with connecting hardware of same category or higher. A. Jacks and Jack Assemblies: 1. Category 6: Color-coded, eight-position, eight wire T568A modular receptacle units with integral IDC-type terminals. Category 6 links shall be terminated using Panduit CJ688TG jack modules. CORNELL UNIVERSITY Phillips Hall Room 333B, 338C & 300UB Renovation Project 27 15 00 - 5 COMMUNICATIONS HORIZONTAL CABLING ERDMAN ANTHONY Project No. 1001X.29 N:\1001X-29-PhillipsHall\Records\Construction\Field Directive\RB-01\271500 - COMMUNICATIONS HORIZONTAL CABLING RB-01.docN:\1001X-29-PhillipsHall\ContentFac\Specifications\271500 - COMMUNICATIONS HORIZONTAL CABLING.DOC9/19/20199/18/2019 9/19/20199/18/2019 2. Category 6A, color-coded, eight-position, eight wire T568A modular receptacle units with integral IDC-type terminals. Category 6A links shall be terminated using Panduit CJ6X88TG jack modules. 2.5 TELECOMMUNICATIONS OUTLET/CONNECTORS 1. Plastic Faceplate: High-impact plastic. Coordinate color with Section 262726 "Wiring Devices." 2. For use with snap-in jacks accommodating any combination of UTP cables. a. Flush mounting jacks. b. Outlets shall be from the same manufacturer as jack modules and be the mini-com executive series single gang with electric ivory bezel (Panduit CFPE4EI). 3. Legend: Machine printed, in the field, using adhesive-tape label. 4. Legend: Snap-in, clear-label covers and machine-printed paper inserts. B. Wireless Access Points: Provide two (2) terminated Category 6A cables to each wireless access point location. 2.6 GROUNDING A. Bonding and Grounding shall conform to ANSI/TIA-607-B Generic Telecommunications Grounding and Bonding (Earthing) for Customer Premises, NEC Articles 250 & 800, as well as any hardware manufacturer grounding requirements. 2.7 IDENTIFICATION PRODUCTS A. Comply with TIA/EIA-606-B and UL 969 for labeling materials, including label stocks, laminating adhesives, and inks used by label printers. B. Comply with requirements in Section 260553 "Identification for Electrical Systems." 2.8 SOURCE QUALITY CONTROL A. Testing Agency: Engage a qualified testing agency to evaluate cables. B. Factory test UTP on reels according to TIA/EIA-568-C. C. Factory test UTP cables according to TIA/EIA-568-C. D. Cable will be considered defective if it does not pass tests and inspections. E. Prepare test and inspection reports. CORNELL UNIVERSITY Phillips Hall Room 333B, 338C & 300UB Renovation Project 27 15 00 - 6 COMMUNICATIONS HORIZONTAL CABLING ERDMAN ANTHONY Project No. 1001X.29 N:\1001X-29-PhillipsHall\Records\Construction\Field Directive\RB-01\271500 - COMMUNICATIONS HORIZONTAL CABLING RB-01.docN:\1001X-29-PhillipsHall\ContentFac\Specifications\271500 - COMMUNICATIONS HORIZONTAL CABLING.DOC9/19/20199/18/2019 9/19/20199/18/2019 PART 3 - EXECUTION 3.1 WIRING METHODS A. Install cables in pathways and cable trays except within consoles, cabinets, desks, and counters. Conceal pathways and cables except in unfinished spaces. 1. Comply with requirements in Section 270528 "Pathways for Communications Systems." B. Conceal conductors and cables in accessible ceilings, walls, and floors where possible. C. Wiring within Enclosures: 1. Bundle, lace, and train conductors to terminal points with no excess and without exceeding manufacturer's limitations on bending radii. 2. Install lacing bars and distribution spools. 3. Install conductors parallel with or at right angles to sides and back of enclosure. 3.2 INSTALLATION OF CABLES A. Comply with NECA 1. B. General Requirements for Cabling: 1. Comply with TIA/EIA-568-C 2. Comply with BICSI ITSIM, Ch. 6, "Cable Termination Practices." 3. Install modular termination hardware unless otherwise indicated. 4. Consolidation points shall not be used. 5. Terminate conductors; no cable shall contain unterminated elements. Make terminations only at indicated outlets, terminals, cross-connects, and patch panels. 6. Cables may not be spliced. Secure and support cables at intervals not exceeding 60 inches (1520 mm) and not more than 6 inches (150 mm) from cabinets, boxes, fittings, outlets, racks, frames, and terminals. 7. Install Velcro tie wraps to restrain cables, to prevent straining connections, and to prevent bending cables to smaller radii than minimums recommended by manufacturer. 8. Bundle and train conductors to terminal points without exceeding manufacturer's limitations on bending radii, but not less than radii specified in BICSI ITSIM, "Cabling Termination Practices" Chapter. Install lacing bars and distribution spools. 9. Do not install bruised, kinked, scored, deformed, or abraded cable. Do not splice cable between termination, tap, or junction points. Remove and discard cable if damaged during installation and replace it with new cable. 10. Cold-Weather Installation: Bring cable to room temperature before dereeling. Heat lamps shall not be used for heating. 11. In the communications equipment room, install a 10-foot- (3-m-) long service loop on each end of cable. CORNELL UNIVERSITY Phillips Hall Room 333B, 338C & 300UB Renovation Project 27 15 00 - 7 COMMUNICATIONS HORIZONTAL CABLING ERDMAN ANTHONY Project No. 1001X.29 N:\1001X-29-PhillipsHall\Records\Construction\Field Directive\RB-01\271500 - COMMUNICATIONS HORIZONTAL CABLING RB-01.docN:\1001X-29-PhillipsHall\ContentFac\Specifications\271500 - COMMUNICATIONS HORIZONTAL CABLING.DOC9/19/20199/18/2019 9/19/20199/18/2019 12. Pulling Cable: Comply with BICSI ITSIM, Ch. 4, "Pulling Cable." Monitor cable pull tensions. C. UTP Cable Installation: 1. Comply with TIA/EIA-568-C 2. Do not untwist UTP cables more than 1/2 inch (12 mm) from the point of termination to maintain cable geometry. D. Group connecting hardware for cables into separate logical fields. E. Separation from EMI Sources: 1. Comply with BICSI TDMM and TIA-569-B for separating unshielded copper voice and data communication cable from potential EMI sources, including electrical power lines and equipment. 2. Separation between open communications cables or cables in nonmetallic raceways and unshielded power conductors and electrical equipment shall be as follows: a. Electrical Equipment Rating Less Than 2 kVA: A minimum of 5 inches (127 mm). b. Electrical Equipment Rating between 2 and 5 kVA: A minimum of 12 inches (300 mm). c. Electrical Equipment Rating More Than 5 kVA: A minimum of 24 inches (610 mm). 3. Separation between communications cables in grounded metallic raceways and unshielded power lines or electrical equipment shall be as follows: a. Electrical Equipment Rating Less Than 2 kVA: A minimum of 2-1/2 inches (64 mm). b. Electrical Equipment Rating between 2 and 5 kVA: A minimum of 6 inches (150 mm). c. Electrical Equipment Rating More Than 5 kVA: A minimum of 12 inches (300 mm). 4. Separation between communications cables in grounded metallic raceways and power lines and electrical equipment located in grounded metallic conduits or enclosures shall be as follows: a. Electrical Equipment Rating Less Than 2 kVA: No requirement. b. Electrical Equipment Rating between 2 and 5 kVA: A minimum of 3 inches (76 mm). c. Electrical Equipment Rating More Than 5 kVA: A minimum of 6 inches (150 mm). 5. Separation between Communications Cables and Electrical Motors and Transformers, 5 kVA or HP and Larger: A minimum of 48 inches (1200 mm). CORNELL UNIVERSITY Phillips Hall Room 333B, 338C & 300UB Renovation Project 27 15 00 - 8 COMMUNICATIONS HORIZONTAL CABLING ERDMAN ANTHONY Project No. 1001X.29 N:\1001X-29-PhillipsHall\Records\Construction\Field Directive\RB-01\271500 - COMMUNICATIONS HORIZONTAL CABLING RB-01.docN:\1001X-29-PhillipsHall\ContentFac\Specifications\271500 - COMMUNICATIONS HORIZONTAL CABLING.DOC9/19/20199/18/2019 9/19/20199/18/2019 6. Separation between Communications Cables and Fluorescent Fixtures: A minimum of 5 inches (127 mm). 3.3 FIRESTOPPING A. Comply with requirements in Section "Penetration Firestopping." B. Comply with TIA-569-B, Annex A, "Firestopping." C. Comply with BICSI TDMM, "Firestopping Systems" Article. 3.4 GROUNDING A. Install grounding according to BICSI TDMM, "Grounding, Bonding, and Electrical Protection" Chapter. B. Comply with J-STD-607-A. 3.5 IDENTIFICATION A. Identify system components, wiring, and cabling complying with TIA/EIA-606-B. Comply with requirements for identification specified in Section 260553 "Identification for Electrical Systems." A.B. Data outlets shall be labeled per Cornell CIT labeling scheme: Room number followed by alpha numeric sequence. The alphabet sequence starts with the first outlet location to the left of the primary entrance of the room and continues clockwise around the room (i.e. the data jacks in the first outlet location left of the door entering Room 101 would be labeled 101-A1 & 101-A2 respectively). 1. Administration Class: 1. 2. Color-code cross-connect fields. Apply colors to voice and data service backboards, connections, covers, and labels. B.C. Cable Schedule: Contractor shall complete CIT cable schedule (template provided by Cornell CIT) and submit to Cornell for service activation planning. Schedule shall be Pposted in prominent location in each equipment room and wiring closet. List incoming and outgoing cables and their designations, origins, and destinations. Protect with rigid frame and clear plastic cover. Furnish an electronic copy of final comprehensive schedules for Project. D. Cabling Administration Drawings: Show building floor plans with cabling administration-point labeling. Identify labeling convention and show labels for telecommunications closets, terminal hardware and positions, horizontal cables, work areas and workstation terminal positions, grounding buses and pathways, and equipment grounding conductors. Follow convention of CORNELL UNIVERSITY Phillips Hall Room 333B, 338C & 300UB Renovation Project 27 15 00 - 9 COMMUNICATIONS HORIZONTAL CABLING ERDMAN ANTHONY Project No. 1001X.29 N:\1001X-29-PhillipsHall\Records\Construction\Field Directive\RB-01\271500 - COMMUNICATIONS HORIZONTAL CABLING RB-01.docN:\1001X-29-PhillipsHall\ContentFac\Specifications\271500 - COMMUNICATIONS HORIZONTAL CABLING.DOC9/19/20199/18/2019 9/19/20199/18/2019 TIA/EIA-606-B. Furnish electronic record of all drawings, in .software and format selected by Owner.DWG format to Cornell CIT. C. D.E. Cable and Wire Identification: 1. Label each cable within 4 inches (100 mm) of each termination and tap, where it is accessible in a cabinet or junction or outlet box, and elsewhere as indicated. 2. Each wire connected to building-mounted devices is not required to be numbered at device if color of wire is consistent with associated wire connected and numbered within panel or cabinet. 3. Exposed Cables and Cables in Cable Trays and Wire Troughs: Label each cable at intervals not exceeding 15 feet (4.5 m). 4. Label each terminal strip and screw terminal in each cabinet, rack, or panel. a. Individually number wiring conductors connected to terminal strips, and identify each cable or wiring group being extended from a panel or cabinet to a building- mounted device shall be identified with name and number of particular device as shown. b. Label each unit and field within distribution racks and frames. 5. Identification within Connector Fields in Equipment Rooms and Wiring Closets: Label each connector and each discrete unit of cable-terminating and connecting hardware. Where similar jacks and plugs are used for both voice and data communication cabling, use a different color for jacks and plugs of each service. 6. Installer shall obtain outlet number configuration for room layouts from the CIT/Infrastructure Engineer. Typically the outlet designations are assigned using the room number followed by letters A-Z in a clock-wise orientation from the left of the primary entrance into the room. E.F. Labels shall be preprinted or computer-printed type with printing area and font color that contrasts with cable jacket color but still complies with requirements in TIA/EIA-606-B. 1. Cables use flexible vinyl or polyester that flex as cables are bent. 3.6 FIELD QUALITY CONTROL A. Testing Agency: Engage a qualified testing agency to perform tests and inspections. B. Perform the following tests and inspections: 1. Visually inspect UTP cable jacket materials for NRTL certification markings. Inspect cabling terminations in communications equipment rooms for compliance with color- coding for pin assignments, and inspect cabling connections for compliance with TIA/EIA-568-C. CORNELL UNIVERSITY Phillips Hall Room 333B, 338C & 300UB Renovation Project 27 15 00 - 10 COMMUNICATIONS HORIZONTAL CABLING ERDMAN ANTHONY Project No. 1001X.29 N:\1001X-29-PhillipsHall\Records\Construction\Field Directive\RB-01\271500 - COMMUNICATIONS HORIZONTAL CABLING RB-01.docN:\1001X-29-PhillipsHall\ContentFac\Specifications\271500 - COMMUNICATIONS HORIZONTAL CABLING.DOC9/19/20199/18/2019 9/19/20199/18/2019 2. Visually confirm Category 6, marking of outlets, cover plates, outlet/connectors, and patch panels. 3. Visually inspect cable placement, cable termination, grounding and bonding, equipment and patch cords, and labeling of all components. 4. UTP Performance Tests: a. Test for each outlet. Perform the following tests according to TIA/EIA-568-C: 1) Wire map. 2) Length (physical vs. electrical, and length requirements). 3) Insertion loss. 4) Near-end crosstalk (NEXT) loss. 5) Power sum near-end crosstalk (PSNEXT) loss. 6) Equal-level far-end crosstalk (ELFEXT). 7) Power sum equal-level far-end crosstalk (PSELFEXT). 8) Return loss. 9) Propagation delay. 10) Delay skew. b. Horizontal cabling shall be permanent link tested with a level 3e tester for full category 6 compliance. c. The dB loss for a horizontal segment must not exceed 2.0dB. 5. Final Verification Tests: Perform verification tests for UTP systems after the complete communications cabling and workstation outlet/connectors are installed. a. Voice Tests: These tests assume that dial tone service has been installed. Connect to the network interface device at the demarcation point. Go off-hook and listen and receive a dial tone. If a test number is available, make and receive a local, long distance, and digital subscription line telephone call. b. Data Tests: These tests assume the Information Technology Staff has a network installed and is available to assist with testing. Connect to the network interface device at the demarcation point. Log onto the network to ensure proper connection to the network. C. Document data for each measurement. Data for submittals shall be printed in a summary report that is formatted similar to Table 10.1 in BICSI TDMM, or transferred from the instrument to the computer, saved as text files, and printed and submitted. D. End-to-end cabling will be considered defective if it does not pass tests and inspections. E. Prepare test and inspection reports. Test results shall be provided on a MS-Windows formatted CD in a common delimited file. E.F. Contractor shall be responsible for submitting the appropriate records and information to Panduit for cabling warranty. CORNELL UNIVERSITY Phillips Hall Room 333B, 338C & 300UB Renovation Project 27 15 00 - 11 COMMUNICATIONS HORIZONTAL CABLING ERDMAN ANTHONY Project No. 1001X.29 N:\1001X-29-PhillipsHall\Records\Construction\Field Directive\RB-01\271500 - COMMUNICATIONS HORIZONTAL CABLING RB-01.docN:\1001X-29-PhillipsHall\ContentFac\Specifications\271500 - COMMUNICATIONS HORIZONTAL CABLING.DOC9/19/20199/18/2019 9/19/20199/18/2019 END OF SECTION 27 15 00 PROJECT:Phillips Hall Rooms 338B; 338C; 300UB Laboratory Renovation DATE: September 19, 2109 RFI Form RFI/ RFI Project Team ResponseResponse Index 1 Need specification , sizes, elevation, manufacturer, type of glass for the 2 operable windows being added. Drawing M-100 has been updated to provide additional information. 2 3 4 5