HomeMy WebLinkAboutPhi Gamma Delta Roof ReplacementTHIS DRAWING IN ANY WAY SON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT, TO A LAW FOR ANY 'S REGULATIONS, PART 69: IT ISA VIOLATION 0 ICLE 147, COMMISSION E EDUCATION LAW, NEW YORK ST ROOF REPLACEMENT Phi Gamma Delta - Oaks 21 CORNELL UNIVERSITY, ITHACA, NEW YORK Issued for Bid: February 13, 2014 ARCH NO.: 1324 LIST OF DRAWINGS: ARCHITECTURAL COVER TOI LOCATION MAE, ABBREVIATIONS 102 CODE SUMMARY, GENERAL NOTES A01 ROOF FLAN 402 SCHEMATIC FLOOR FLANS AND INSULATION SCORE DIAGRAMS AI I 412 DETAILS I DETAILS I I AROI ASBESTOS ABATEMENT NOTES AND DETAILS AR02 ASBESTOS ROOFING ABATEMENT FLAN l The AroStterstrkkoldineer eedthe tot le the best ot Ilkeir knowledge, ! wiernorion red the pedts one speetherniens dre secordanee ! wlth nEgkelehle requeethents et the Breldlog Codes of rgeg York Stole, !the Energy Consecrated-, Corsdnedien Code of N.,,1ork State. ! and Ete Dethgn and Consetronen Swdards Cednell hinagyslry. GSBURY› Nom- Kingsbury Architecture LLC 106 E. Court St., Ithaca, NY 14850-4272 phone: 607-273-'1477 lax: 607-273-1333 web: kingsburyarch.com THIS DRAWING IN ANY WAY SON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT, TO A LAW FOR ANY RT 69: IT ISA VIOLATION 0 'S REGULATIONS, P E EDUCATION LAW, ARTICLE 147, COMMISSION NEW YORK ST ABBREVIATIONS AB ACM ACOUS ADJ AFF A ALT AL ANCA AFFROX ARCA AVG BOC BD BLDG BLK BLKG BM BOF BOT BS BRG BTWN BUR C CAB CB CHEM CI CIF CJ CJW CLO CLO CLR CMP CMJ COL COMP CONIC CONSTR CONT COCRD CORR CPT CT CTR CSINK D DBL DEMO DISP ON DO DR DRH DS DTL DWG DWR ANCHOR BOLT ASBESTOS -CONTAIN NG MATERIAL ACOUSTICAL ADJUSTABLE ABOVE FINISH FLOOR AIR ALTERNATE ALUMINUM ANCHORING APPROXIMATELY ARCHITECTURAL AVERAGE BOTTOM OF CURB BOARD BUILDING BLOCK BLOCKING BEAM BOTTOM OF FOOTING BOTTOM BOTH SIDES BEARING BETWEEN BUILT-UP ROOF COURSE(S) CABINET CATCH BASIN CHEMICAL CAST IRON CAST -IN-PLACE CONTROL JOINT CONSTRUCTION JOINT WITH WATERSTOF CEILING CLOSET CLEAR CORRUGATED METAL FIFE CONCRETE MASONRY UNIT COLUMN COMPRESSED CONCRETE CONSTRUCTION CONTINUOUS COORDINATE CORRUGATED CARPET CERAMIC TILE COUNTER COJNTERSINK DRYER DOUBLE DEMOLITION DISPENSER DOWN DITTO DOOR DOUBLE ROBE N00K DOWNSPOUT DETAIL DRAWING DRAWER EA EC EJ ELEC ELEV EQ EQJIP ER ES EV EW EX EXIST EXP EXT FD FE(C) FF FIN FN FIXT FLR FLUOR FND FOC FOM FOS FP FR FRP FRT FS FT FTG G GA GALV GC GL GND GWB GYP NC AOR N00D HDWR HORIZ NT HVAC ID INLAND INSUL INT INV JAN JT KS LAM LAV LT EACH ELECTRICAL CONTRACTOR EXPANSION JOINT ELECTRICAL ELEVATION EQUAL EQJIPMENT EXISTING RELOCATED EMERGENCY SHOWER EXISTING VENT EYEWASH EXISTING EXISTING EXPANSION EXTERIOR FLOOR DRAIN FIRE EXTINGUISHER (CABINET) FINISH FLOOR FINISH( ED) FUME NCOD FIXTURE FLOOR FLUORESCENT FOUNDATION FACE OF CONCRETE FACE OF MASONRY FACE OF STUD FIRE PROTECTION FIRE RATED FIBERGLASS REINFORCED PLASTIC FIRE -RETARDANT TREATED FOOTING STEP FOOT, FEET FOOTING GAS, GLASS GAUGE GALVANIZED GENERAL CONTRACTOR GLASS GROUND GYPSUM WALL 50ARD GYPSUM HANDICAPPED HEADER HARDWOOD HARDWARE HOLLOW METAL HORIZONTAL HEIGHT HEATING, VENTILATION AND AIR CONDITIONING INSIDE DIAMETER INCANDESCENT INSULATION INTERIOR INVERT JANITOR JOINT KNEE SPACE LAMINATE LAVATORY LIGHT MAR MAS MAX MC MEGA MEP MFR MA MIN MISC MO MTD MTL MUL NIC NO NOM NTS 00 OC OD ON OPNG OFF FLAM PC PL FL,AS PLYWD PSF F51 PT, PNT PTD FTN FTWD MARBLE MASONR" MAXIMUM MECHANICAL CONTRACTOR MECHANICAL MECHANICAL, ELECTRICAL AND PLUMBING MANUFACTURER MANHOLE MINIMUM MISCELLANEOUS MASONRY OPENING OOJNTED METAL MULLION NOT IN CONTRACT NJMBER NOMINAL NOT TO SCALE OVERALL ON CENTER OUTSIDE DIAMETER OVERHEAD OPENING OPPOSITE PLASTIC LAMINATE PLUMBING CONTRACTOR PLATE PLASTIC PLYWOOD POJNDS PER SOJARE FOOT POUNDS PER SQUARE INCH PAINT PAINTED PARTITION PRESSURE -TREATED WOOD QT QUARRY Ti LE (R) R RAD RCB REFRIG REINF REO'D RESIL RN R0 RR RTL RELOCATED RISER RADIATOR RESILIENT COVE BASE REFRIGERATED REINFORCED REQJIRED RESILIENT ROSE N00K ROUGH OPENING REMOVE AND RELOCATE ROOFTOP UNIT SACP SUSPENDED ACOUSTIC CEILING PANEL SC 5AWCUT SGFT STRUCTURAL GLAZED FACING TILE SNR SHOWER SAT SHEET SIM SIMILAR SJ SCORE JOINT SOG SLAB ON GRADE SPECS SPECIFICATIONS SQ SQJARE SS STAINLESS STEEL STD STANDARD STL STEEL STRUCT STRUCTURAL 5655 SLSPENDED SYM SYMMETRICAL T T&B T&G TB TOC TEL TEMP TN TO1 TOL TOS TCW -Fp TYP UNO V VAR VAT VCT VERT VEST VIF VR 006 W/ W/D W/0 WC WD W DO ON WP WR WSCT WT WWM TREAD TOP AND BOTTOM TONGUE AND GROOVE TACK BOARD TOP OF CURB TELEPHONE TEMPORARY THICK TOP OF FOOTING TOP OF LEDGE TOP OF STEEL TCP OF WALL TOILET PAPER DISPENSER TYPICAL UNLESS NOTED OTHERWISE 0ACJJ0 VARIES VINYL ASBESTOS TILE VINYL COMPOSITE TILE VERTICAL VESTIBULE VERIFY IN FIELD VAPOR RETARDER VINYL WALL COVERING WITH WASHER/DRYER WITHOUT WATER CLOSET, WATER COOLER WOOD WINDOW WATER NEATER WATERPROOF, WORKING POINT WATER-RESISTANT WAINSCOT WEIGHT WELDED WIRE MESH - PHI GAMMA DELTA - OAKS 21 I16 MCGRAW PLACE_ JOUNSON ('MUSEUM O° A LOCATION 1"IAP OWNER NO.: ARCH NO.: 1324 LOCATION MAP, ABBREVIATIONS DATE: SCALE: 2/13/14 NONE DWG No.: T01 } CODE SUHMARM } z TO THE BEST OF OUR KNOWLEDGE, INFORMATION AND BELIEF, THESE PLANS ARE IN COMPLIANCE WITH THE BUILDING CODES OF NEW YORK STATE AND WI TN THE DESIGN STANDARDS OF CORNELL F 00 VERSIT'0 IF DISCREPANCIES ARE FOUND BETWEEN THE DRA✓iINGS, OR BETWEEN THE DRAWINGS Fc AND THE CODES, TOE MORE STRINGENT REQUIREMENTS SHALL APPLY. B0ILDING CODE OF NEW YORK STATE CHAPTER 3 USE AND OCCUPANCY CLASSIFICATIONS I. OCCUPANCY CLASSIFICATION: RESIDENTIAL GROUP R2 FRATERNITIES, 310.1 CHAPTER 6 TYPES OF CONSTRUCTION IT ISA VIOLATION OF THE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT, TO ALT E EDUCATION LAW, ARTICLE 147, COMMISSIONERS REGULATIONS, PART 69: NEW YORK ST CONSTRUCTION CLASSIFICATION, TYPE V5, TABLE 001 FIRE RESISTANCE RATING, 0 1-100R5 CHAPTER 12 INTERIOR ENVIRONMENT I. VENTILATION: ENCLOSED ATTICS AND ENCLOSED RAFTER SPACES FORMED WHERE CEILINGS ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF FRAMING MEMBERS SHALL HAVE CROSS VENTILATION FOR EACH SEPARATE SPACE BY VENTILATING OPENINGS PROTECTED AGAINST ENTRANCE OF RAIN AND SNOW. A MINIMUM OF ONE INCH OF AIR SPACE SHALL BE PROVIDED BETWEEN THE INSLL AND ROOF SHEATHING. THE NET FREE VENTILATING AREA SHALL NOT BE LESS THAN 1/150 OF THE AREA OF THE SPACE VENTILATED, WI TN 50 PERCENT OF THE REQUIRED VENTILATING AREA PROVIDED BY VENTILATORS LOCATED IN THE UPPER PORTION OF THE SPACE TO 55 VENTILATED AT LEAST THREE FEET ABOVE THE EAVE OR CORNICE VENTS WI TN THE BALANCE OF THE REQUIRED VENTILATION PROVIDED BY EAVE OR CORNICE VENTS, 1203.2. REDUCED VENTILATION AREA EXCEPTION IS ALLOWED IF A 154 ROOFING FELT IS PROVIDED ON THE WARN 51 DE OF THE ATTIC INSUL. CHAPTER 15 ROOF ASSEMBLIES COMPLY WITH ALL CODE REQUIREMENTS APPLICABLE TO SYSTEM] INSTALLED 2. REQUIREMENTS FOR ROOF COVERINGS, COMPLY WITH 1507.2 FOR ASPHALT SHINGLES 3 FIRE CLASSIFICATION, TABLE 1505.1 MINIMUM CLASS C CHAPTER 26 PLASTIC SURFACE BURNING CHARACTERISTICS OF FOAM PLASTIC INSUL= FLAME SPREAD INDEX NOT MORE THAN 75 AND SMOKE DEVELOPED INDEX NOT MORE THAN 450, 2603.3 2 THERMAL BARRIER: FOAM PLASTIC INSUL SHALL BE PROTECTED BY 0.5 INCH GWB OR EQUIVALENT, 2603.4 3. ATTICS AND CRAWLSPACES: THERMAL BARRIER NOT REQUIRED WHERE FOAM PLASTIC INSUL IS PROTECTED AGAINST IGNITION BY 0.25 INCH THICK WOOD STRUC PANEL OR MIN 0.016 INCH CORROSION -RESISTANT STEEL (IGNITION BARRIER), 2003.4.1.0 EXISTING BU LDI NG: CODE L CLASSIFICATION OF WORK LEVEL I: WORK INVOLVES REMOVAL AND REPLACEMENT OF ROOFING MATERIALS. COMPLY WITH CHAPTER 6, 403.1 2. ENERGY CONSERVATION: COMPLY WITH SECTION 101 OF ENERGY CODE, 607 3. RE -ROOFING: COMPLY WITH CHAPTER 15 OF BLDG CODE, 008 CHAPTER 6 ALTERATIONS -LEVEL L REROOFING: CCMPL" WITH CHAPTER 15 OF BLDG CODE OF NYS, 008 ENERGY CONSERVATION CODE I. GENERAL REQUIREMENTS: ROOFS WHERE THE SHEATHING IS EXPOSED DURING RE -ROOFING 0UST COMPLY 4TH THE ENERGY CODE. ROOFS WITHOUT INSUL IN THE CAVITY AND WHERE THE SHEATHING OR INSUL IS EXPOSED DURING REROOFING SHALL BE INSULATED EITHER ABOVE OR BELOW THE SHEATHING CONFORMING WITH PROVISIONS FOR NEW CONSTRUCTION, 101.4.3. 2. TABLE 301.1: TOMPKINS COUNTY, CLIMATE ZONE 6 ENVELOPE TABLE 502.2(1) ATTIC INSUL R-38 INSULATION ENTIRELY ABOVE DECK R-20, CONTINUOUS, 502.2(1) A. VAPOR RETARDERS: REQUIRED ON ALL FRAMED CEILINGS WHERE THE FRAMED CAVITY IS NOT VENTILATED TO ALLOW MOISTURE TO ESCAPE, 502.5 GENERAL NOTES THIS SECTION SUMMARIZES SELECTED MAJOR SCOPES AND WORK REQUIREMENTS. PERFORM WORK IN ACCORDANCE 4TH ALL CONTRACT DOCUMENTS. "ACM" DENOTES ASBESTOS CONTAINING MATERIALS. ABATE ACM ROOFING N FULL COMPLIANCE WITH INDUSTRIAL CODE RULE 56. REFER TO GENERAL REQUIREMENTS AND DIVISION 2 SPECIFICATIONS AND ASBESTOS ABATEMENT DRAWINGS. ROOF SCOPES ROOFS RI, R5, R6 REMOVE EXIST ASPHALT SHINGLE ROOFING AND FELTS DOWN TO EXIST SHEATHING TO REMAIN. PROVIDE UNDERLAYMENT, SELF -ADHERING UNDERLAYMENT, ASPHALT SHINGLES. ROOF R2 REMOVE EXIST ASPHALT SHINGLE ROOFING, FELTS, ROOF BOARDS AND SHEATHING DOWN TO EXIST FRAMING TO REMAIN. PROVIDE IGNITION BARRIERS, SPRAY FOAM INSUL, SHEATHING, UNDERLAYYENT, SELF -ADHERING UNDERLAYMENT, ASPHALT SHINGLES. ROOF R3 SIN ROOF R2 except ADJUST OR DELETE IGNITION BARRIER SCOPE AS REQUIRED TO REFLECT EXISTING CONDITIONS. VI F. ROOF RL (FLAT ROOF), ROOFS DI TO 012 (GABLE AND SHED DORMERS) REMOVE EXIST ACM -COATED METAL ROOFING, AND SHEATHING. PROVIDE SHEATHING, NON - ASPHALTIC UNDERLAYMENT, SELF -ADHERING UNDERLAYMENT, AND FLAT -SEAN METAL ROOFING. OTHER MAJOR SCOPES IVY REMOVAL: REFER TO DRAWING A01. INSULATION SCOPES: REFER TO DRAWING 402. EXIST GABLE AND SOFFIT VENTS: CLEAN. ROOF PENETRATIONS: RESEAL AT ALL LOCATIONS WHERE ACM SEALANTS ARE REMOVED. GUTTERS AND DOWNSPOUTS: REMOVE EXISTING. INSTALL NEW MATERIALS IN EXISTING LOCATIONS. REFER TO SECTION 07 02 00. PAINTING: PREP AND PAINT PREVIOUSLY PAINTED SURFACES ABOVE ROOF LINES OF ROOFS RI AND R2, THE ENTIRETY OF CHIMNEYS THAT START BELOW THE ROOF LINES OF ROOFS RI AND R2 AND TERMINATE ABOVE THEM, AND SPECIFIED PORTIONS OF FASCIAS, SOFFITS AND TRIM. REFER TO SECTION 03 31 00. SITE USE AND PROTECTION OWNER WILL OCCUPY BUILDING DURING CONSTRUCTION PERIOD. PROVIDE TEMPORARY PROTECTION AT MAIN BUILDING ENTRANCE. PROVIDE TEMPORARY ROOF PROTECTION AT THE END OF EACH DA" AS REQUIRED TO PROTECT WORK IN PROGRESS AND TO PROTECT INTERIOR OF BUILDING FROM ELEMENTS. STAGING: OWNER WILL DESIGNATE PARKING AND STAGING AREAS ON SITE. EXIST SPRINKLER SYSTEM IN ATTIC AND THROUGHOUT BUILDING TO REMAIN. PROTECT EXISTING AND NEW EXTERIOR AND INTERIOR WORK PER SECTION 01 66 00 AND AS OTHERWISE REQUIRED BY EXISTING CONDITIONS. SUBMIT PROTECTION PLAN FOR INTERIORS BEFORE START OF WORK. CONTRACTOR SHALL, AT ITS OWN COST, REPAIR, REPLACE AND/OR REFINISH ALL DAMAGE CAUSED BY ITS WORK TO OWNER'S SATISFACTION. 0 E REQUIREMENTS FRE -CONSTRUCTION PHOTOS: REFER TO GENERAL REQUIREMENTS SECTION 01 32 33, PHOTOGRAPHIC DOCUMENTATION. AT PROJECT START, RECORD AND SU5 IIT ELECTRONIC PHOTOGRAPHIC RECORDS OF INTERIOR AND EXTERIOR EXISTING CONDITIONS, INCLUDING ALL CEILING FINISHES IN ALL SPACES WHICH ARE BELOW ROOFS. LABEL ALL PHOTOGRAPHS FOR LOCATIONS AROUND AND WITHIN BUILDING. OBTAIN OWNER APPROVAL OF PHOTOS BEFORE PROCEEDING WITH WORK. OWNER NO.: ARCH NO.: 1324 CODE SUMMARY, GENERAL NOTES DATE: SCALE: 2/13/14 NONE DWG No.: T02 THIS DRAWING IN ANY WAY SON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT, TO A LAW FOR ANY RT 69: IT ISA VIOLATION 0 'S REGULATIONS, P E EDUCATION LAW, ARTICLE 147, COMMISSION NEW YORK ST NUMBERED NOTES ROOF R1: LATEST ADDITION. EXIST PLYWD DECK AND PERF SOFFITS TO REMAIN. REMOVE EXIST OSHINGLES, ROOFING FELTS, RIDGE VENTS AND OTHER MATLS TO EXIST DECK. INSTALL SELF -ADHERING UNDERLAYMENT, UNDERLAYMENT, SHINGLES, AND RIDGE VENTS. O O O ROOF R2- ORIGINAL BUILDING AND EARLIER ADDITIONS. REFER TO DWG 1/011 FOR T"PICAL WORK SCOPE THROUGH GABLED MAIN ROOFS. REMOVE EXIST CONT GUTTER, TAP. INSTALL NEW TO MATCH EXIST CONFIGURATION. REMOVE EXIST DOWNSPOUTS, TYP. INSTALL NEW TO MATCH EXIST CONFIGURATION. O O O CONT SMARTVENT, T"P. A. EAVE INTAKE. B. MID -ROOF INTAKE. C. OFF-PEAK EXHAUST. CONT RIDGE VENT, TYP. REMOVE EXIST ITL DIVERTER. INSTALL NEW TO MATCH EXIST CONFIGURATION. FIELD -MEASURE EXIST METAL ROOFING, FLASHING AND/OR CRICKETS. REMOVE. INSTALL NEW TO MATCH EXIST CONFIGURATIONS. O 10 R2 R1 REMOVE AND REPLACE EXIST STEP FLASHINGS AND CCUNTERFLASHINGS AT JOINTS BETH MAIN ROOFS AND DORMER WALLS, TYP. REMOVE EXISTING IVY ON NORTH SIDE IN ITS ENTIRETY FROM GROUND LP. VIF SCOPE. PAINTING SCOPE INCLUDES BUT IS NOT LIMITED TO FOLLOWING. REFER TO SECTION 0P 91 00. A. ENTIRE CHIMNEY. B. GABLE END ENTIRELY ,ABOVE LOWER PORTION OF ROOF R2. 191-2" 17'-0" 101 0" 14L-0' 27'-7' EX SATELLITE DISH TO REMA N (2) 4732_012 4732_042 4732_013 EX SMOKE HATCH TO REMAIN EX GOOSENECK TO REMAIN 4732_003 4732_004 4732_020 4732_040 4732_038 4732_002 4732_001 V 4732_038 4732_030 4732_036 4732_035 4732_034 4732_033 4732_032 O O :• i ---- GENERAL NOTES 1. ALL DIMENSIONS ARE APPROXIIYATE. VIF. 2. APPROXIMATE ROOF SLOPE R 12. VIF. R2 R1 ROOF FAN NO TN CORNELL UNIVERSITY ROOF INVENTORY PANEL NUMBER FOR OWNER'S USE, TYP OWNER NO.: ARCH NO.: 1324 ROOF PLAN DATE: SCALE: 2/1 3/1 4 1 /16" =1 '-0" DWG No.: A01 THIS DRAWING IN ANY WAY SON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT, TO A LAW FOR ANY RT 69: IT ISA VIOLATION 0 'S REGULATIONS, P E EDUCATION LAW, ARTICLE 147, COMMISSION NEW YORK ST 30060 30004 STAIR ACCESS TO EXTERIOR GRADE EXIST CEILING HATCH, SEE INSUL SCOPE E 30020 30031 2020 202 2028 202C 2040 20040 205 206 2080 204 2045 2040 2115 2110 211 20044 ROOF LINE ABOVE, TYP CEILING LINE ABOVE, TYP CUT THROUGH ROOF PLANE, TYP ROOF LINE BELOW, TYP 3rd FLOOR PLAN NOT TO SCALE 20004 215 STAIR ACCESS TO EXTERIOR GRADE 2200 20021 20042 20001 208 20002 203 210 214 20045 CEILING LINE ABOVE, TYP ROOF LINE ABOVE, TYP 2nd F.LOOR PLAN NOT TO SCALE 216 r 220 218 INSUL SCOPE LEGEND INSUL SCOPE A REFER TO DWG 3/All. REMOVE EXIST BATT INSUL FROM FLAT CEILING. INSTALL FOAM INSUL ON EXIST LATA AND PLASTER. INSUL SCOPE B REFER TO DWG 3/All AND 4/All. REMOVE EXIST LOOSE FILL INSUL FROM RAFTER SPACES. INSTALL FOAM INSUL ON EXIST LATH AND PLASTER. MAINTAIN H AIR SPACE. NSUL SCOPE ..0 REFER TO DWG 3/All AND I/All. INSTALL IGNITION BARRIER COMPLIANT WITH BCNYS 2300.4.1.0 BETW RAFTERS AND JOISTS. INSTALL FOAM INSUL. MAINTAIN H AIR SPACE. INSUL SCOPE D REFER TO DWG 2/Al2. REMOVE ASSUMED EXIST BATT INSUL FROM FLAT DORMER CEILING. INSTALL FOAM INSUL ON EXIST LATH AND PLASTER. INSUL SCOPE E REFER TO DWG 2/All. ON FLAT CEILING, INSTALL BATT INSUL OVER EXIST BATT INSUL TO REMAIN. ACCESS CONCEALED WORK SPACE THROUGH EXIST CEILING HATCH IN CLOSET 30000. VERIFY WORK AND ACCESS CONDITIONS IN CONCEALED SPACE. DWG A02 NOTES PLANS ARE NOT TO SCALE. ROOF LINES AND INSULATION SCOPES ARE SHOWN SCHEO1ATICALL" FOR GENERAL COORDINATION WITH FLOOR AREAS BELOAI. EXACT ALIGNMENTS HAVE NOT BEEN VERIFIED. PERFORM EXPLORATORY DEMOLITION AS REOUIRED IN AREAS WHERE FIELD VERIFICATION OF EXACT ALIGNMENTS OR ACCESS CONDITIONS IS CRITICAL. PATCH/MATCH WHEN COMPLETE. OWNER NO.: ARCH NO.: 1324 SCHEMATIC FLOOR PLANS AND INSULATION SCOPE DIAGRAMS DATE: SCALE: 2/13/14 NONE DWG No.: A02 THIS DRAWING IN ANY WAY SON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT, TO A LAW FOR ANY RT 69: IT ISA VIOLATION 0 'S REGULATIONS, P E EDUCATION LAW, ARTICLE 147, COMMISSION NEW YORK ST CAP SHINGLE RIDGE VENT CONT 3/4" SLOT, TYP INSUL SCOPE A EXIST 2x8 RAFTER BEYOND TO REMAIN FOA"' INSUL i 12 WirPIPTA OgAlkletrt 0 +/-, VIF AIR SPACE, MIN. 1', MAX 1 1/2' REMOVE EXIST ROOF BOARDS, INSTALL PLYWD SHEATHING UNDERLA''MENT SHINGLES CAP SHINGLE RIDGE VENT CONT 3/4' SLOT, TYP EXIST 2x8 RAFTER BEYOND TO REMAIN 6" UNFACED FIBERGLASS BATT INSUL PERPENDICULAR TO JOISTS BAFFLE EACH JOIST BAY MAINTAIN EXIST AIR SPACE UNDERLAYMENT LAP SELF -ADHERING UNDERLAYMENT INSUL SCOPE E (NOTE 2) EXIST SHEATHING TO REMAIN EXIST BATT INSUL TO REMAIN 12 EXIST LATH AND PLASTER TO REMAIN REMOVE EXIST LOOSE FILL INSUL REMOVE EXIST BATT INSUL BCNYS 2306/ THERMAL BARRIER: EXIST LATH AND PLASTER TO REMAIN i i i BCNYS 2300.4.1.6 IGNITION BARRIER: IGNITION BARRIER SHEATHING Hr 0 +/-, VIF SELF -ADHERING UNDERLA''MENT CONT DRIP EDGE FASCIA HANGER, 24' 0.C. MAX CONT GUTTER, SEE DWG 5/All 3' DIA. DNSPT FOAM INSUL EXIST 2x8 RAFTER TO REMAIN BCNYS 2300.4 THERMAL BARRIER: EXIST LATH AND PLASTER TO REMAIN SHINGLES UNDERLAYMENT REMOVE EXIST ROOF BOARDS, INSTALL PLYWD SHEATHING- " AIR SPACE EXIST LATH AND PLASTER ONE SIDE OF WALL STUDS TO REMAIN DWG All NOTES COORD SLOT LOCATIONS WITH SMARTVENT LA"OUT. TERMINATE SLOTS 12' FROM HIPS, VALLEYS AND ROOF -WALL JOINTS. 2. WORK OF INSUL SCOPE E TO TAKE PLACE IN CONFINED SPACE HITN LIMITED ACCESS THROUGH EXIST CEILING HATCH. FIELD -VERIFY ACCESS AND WORK CONDITIONS. SEE SECTION 00 01 00 FOR PAINTING SCOPE. UNDERLAYMENT / LAP SELF -ADHERING UNDERLAYMENT 3"+/ - MIN 7' SELF -ADHERING UNDERLAYMENT TO RUN OVER SMARTVENT SMARTVENT CONT 1 1/2" SLOT (NOTE 1) - STRAP HANGER, 24 0.C. MAX CONT DRIP EDGE CONT GUTTER, SEE DWG BCNYS 2306.4.1.6 IGNITION BARRIER IGNITION BARRIER SHEATHING 1x2 NAILER EA SIDE OF EXIST JOIST, REMOVE ASSUMED INSUL AS REO'D ASSUMED EXIST WALL INSUL TO REMAIN 3" DIA. DNSPT EXIST OGEE TO REMAIN PAINT (NOTE 3) 5/All EXIST WALL INSUL TO REMAIN EXIST CONT SOFFIT VENT TO REMAIN SHINGLES UNDERLAYMENT REMOVE EXIST ROOF BOARDS, INSTALL PLYWD SHEATHING AIR SPACE, MIN. 1', MAX 1 1/2" EXIST FASCIA TO REMAIN PAINT (NOTE 3) FOAM INSUL IGNITION BARRIER SHEATHING CONT LT GAGE ANGLE, MIN. 0.016 INCH CORROSION - RESISTANT STEEL BCNYS 2306.4. 16 IGNITION BARRIER EXIST 2x8 RAFTER TO REMAIN OWNER NO.: ARCH NO.: 1324 DETAILS 1 DATE: SCALE: 2/13/14 3/4" -1'-0" DWG No.: A 1 1 THIS DRAWING IN ANY WAY SON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT, TO A LAW FOR ANY RT 69: IT ISA VIOLATION 0 'S REGULATIONS, P E EDUCATION LAW, ARTICLE 147, COMMISSION NEW YORK ST EILAT MTL ROOFING PANEL CONCEALED CLIP, TWO PER EDGE CONT SOLDERED FLAT SEAN, TYP NON -ASPHALTIC UNDERLAYMENT SELF -ADHERING UNDERLAYMENT 1/4 12 CONT NTL COLNTERFLASHNG CONT MTL FLASHING CONT STRIP UNDERLA"MENT CONCEALED NTL CLIP, 9' 00 ,LAT MTL ROOFING PANEL NON -ASPHALTIC UNDERLAYMENT SELF -ADHERING UNDERLAYNENT REMOVE EXIST WOOD DECK AND FRAMING, INSTALL PLYWD SHEATHING SHINGLES LNDERLAYMENT DETA 3" = 12 1/4 CONT 2x4, TYP 2x4 BEYOND, 16 OC, RIP AS REO'D FOR ROOF SLOPE CONT 2x4, TYP, RIP A5 REO'D FOR ROOD SLOPE EXIST FRAMING TO REMAIN ROOF R4 3/4" = 11-0" ROOF 07, FLAT PORTIONS OF ROOFS 06 AND 010 SIMILAR 12 VIF METAL ROOFING PANEL /— NON -ASPHALTIC UNDERLA"MENT SELF ADHERING UNDERLAYMENT REMOVE EXIST WOOD DECK, INSTALL PLYWD SHEATHING BCNYS 23C6.4 THERMAL BARRIER' EXIST LATH AND PLASTER TO REMAIN INSUL SCOPE D: I) REMOVE ASSUMED EXIST BATT INSUL 2) FOAM INSUL (2) 2x6 LEDGER INSJL SCOPE VARIES BY LOCATION CONCEALED MIL EDGE CLIP, 9' 0.0 EXIST TRIM TO REMAIN 0 z Q 0 - SEE SECTION 0c1 9] 00 FOR PAINTING SCORE. GAEL_E DORI" IERS 3/4" = 1'-0' REFASTEN EXIST T-111 CONT MTL COJNTERFLASHING RIVET, ONE E'ER SHINGLE COJRSE MTL STEP FLASHING SHINGLES UNDERLATMENT PLT -WD SHEATHING 15. NEW WORK LOOSEN EXIST T-111 EXT SIDING A5 REO'D FOR FLASHING WORK REMOVE EXIST FLASHINGS REMOVE EXIST SHINGLES REMOVE EXIST ROOF BOARDS SAWCUT WITHIN 1/2' OF EXIST SIDING IA DEMOLITION DORI"IER BASE -WALL JOINT 3/4" = 1'-0" OWNER NO.: ARCH NO.: 1324 DETAILS 11 DATE: SCALE: 2/13/14 NOTED DWG No.: Al2 ASBESTOS ABATEMENT NOTES: 1. THE NOTES AND DETAILS PRESENTED HERE AND IN SPECIFICATION SECTION 028213 ARE APPLICABLE TO DRAWING AR02. ASBESTOS ROOFING ABATEMENT OPERATIONS SHALL BE PERFORMED AT THE PHI GAMMA DELTA - OAKS 21 HOUSE (BUILDING 4732) ROOF LOCATED AT 118 MCGRAW PLACE ON THE CORNELL UNIVERSITY CAMPUS IN ITHACA, NEW YORK. 2. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS, DIMENSIONS AND QUANTITIES. ANY DISCREPANCIES SHALL BE BROUGHT TO THE OWNERS ATTENTION PRIOR TO BID. 3. THE CONTRACTOR SHALL PERFORM ALL CONTRACT WORK IN ACCORDANCE WITH THE CONTRACT DOCUMENTS, DRAWINGS, AND SPECIFICATIONS. ASBESTOS ABATEMENT OPERATIONS SHALL BE PERFORMED AS PER THE PROVISIONS AND CONDITIONS LISTED IN THE NEW YORK STATE DEPARTMENT OF LABOR (NYS DOL) INDUSTRIAL CODE RULE NO. 56 (CITED AS 12 NYCRR PART 56) AND APPLICABLE OSHA, NESHAPS AND OTHER PERTINENT CODES. 4. ROOF ABATEMENT OPERATIONS SHALL INCLUDE THE REMOVAL OF THE FOLLOWING ASBESTOS CONTAINING/ASBESTOS CONTAMINATED MATERIALS: A) APPROXIMATELY 800 SQUARE FEET OF ROOF COATING/SILVER SEALANT APPLIED TO THE DORMERS METAL ROOFING, VARIOUS FLAT ROOF SECTIONS, VARIOUS VALLEYS, VENT STACKS, AND LOCALIZED RANDOMLY THROUGHOUT THE ROOF AS A REPAIR MECHANISM. THE ACM COATING/SILVER SEALANT AND ASSOCIATED SUBSTRATE SHALL BE REMOVED AT ALL LOCATIONS WHERE PRESENT. B) APPROXIMATELY 120 SQUARE FEET OF FLASHING TAR APPLIED AT THE DORMER WALL -TO -ROOF FLASHINGS. REFERENCE DETAIL 1 ON DRAWING Al 2 FOR ADDITIONAL DORMER DEMOLITION INFORMATION. C) APPROXIMATELY 4 SQUARE FEET OF BLACK CAULK APPLIED RANDOMLY THROUGHOUT THE ROOF AT VARIOUS ROOF PENETRATIONS. 5. THE REMOVAL OF THE ASBESTOS CONTAINING/ASBESTOS CONTAMINATED ROOFING MATERIALS SHALL BE PERFORMED AS PER THE PROVISIONS AND CONDITIONS OF 12 NYCRR PART 56-11.1 FOR IN -PLANT OPERATIONS. 6. ALL NOB ACM WASTE SHALL BE PROPERLY PACKAGED, TRANSPORTED AND DISPOSED OF AS NOB C&D IN ACCORDANCE WITH ALL FEDERAL, STATE AND LOCAL REGULATIONS. 7. THE CONTRACTOR SHALL COORDINATE THE SCHEDULED WORK WITH THE OWNER'S REPRESENTATIVE AND ALL OTHER TRADES. 8. THE CONTRACTOR SHALL MAINTAIN SECURITY IN EACH WORK AREA AT ALL TIMES. 9. THE CONTRACTOR SHALL SUBMIT A WRITTEN WORK PLAN FOR ASBESTOS ABATEMENT OPERATIONS FOR REVIEW AND APPROVAL AS PER THE REQUIREMENTS OF SPECIFICATIONS SECTION 028213, 1.04. 10. ALL EQUIPMENT ON THE ROOF WORK AREA, ONE FLOOR BELOW THE ROOF AND WITHIN 25' OF THE ACTIVE REGULATED ABATEMENT AREA, INCLUDING BUT NOT LIMITED TO OPERABLE WINDOWS, AIR INTAKES, VENTS, VENTILATORS AND ANY OTHER OPENINGS INTO THE BUILDING SHALL BE COVERED AND SEALED WITH TWO (2) LAYERS OF 6 -MIL FIRE RETARDANT POLYETHYLENE SHEET. SHOULD THE WORK INTERFERE WITH VENTING PLUMBING STACKS, FACILITY USERS MUST BE CONTACTED PRIOR TO COVERING OR SEALING. 11. ALL PROJECT MONITORING REQUIRED TO SATISFY THE REQUIREMENTS OF 12 NYCRR PART 56 SHALL BE PERFORMED BY A THIRD PARTY INDEPENDENT ENVIRONMENTAL CONSULTANT HIRED DIRECTLY BY THE OWNER. THE CONTRACTOR SHALL COORDINATE WITH THE THIRD PARTY CONSULTING FIRMS ONSITE ASBESTOS PROJECT MONITOR (APM). AIR MONITORING TO SATISFY OSHA REQUIREMENTS SHALL BE THE CONTRACTORS RESPONSIBILITY. 12. COORDINATE ALL ASBESTOS ABATEMENT (INCLUDING BUT NOT LIMITED TO WORK AREA CONFIGURATIONS AND SEQUENCE OF ABATEMENT) WITH THE OWNER'S REPRESENTATIVE. 13. COORDINATE HOOK-UP OF WATER SOURCE/SERVICE FOR ABATEMENT WORK AND DECONTAMINATION PURPOSES WITH THE OWNER. TEMPORARY WATER CONNECTIONS SHALL BE MADE BY THE CONTRACTOR AND MAINTAINED IN A LEAK FREE STATE AT ALL TIMES. 14. UNDER NO CIRCUMSTANCES SHALL CONTAMINATED LIQUIDS OR DEBRIS ENTER THE EXISTING SEWER SYSTEM. ALL WASTEWATER SHALL BE FILTERED THROUGH A SYSTEM WITH AT LEAST 5.0 MICRON PARTICLE SIZE COLLECTION CAPABILITY. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY WASTE WATER PERMITS REQUIRED TO PERFORM HIS WORK UNDER THIS CONTRACT. ANY COST ASSOCIATED WITH WASTE WATER PERMITS SHALL BE INCLUDED IN HIS BID. 15. CONTINUAL WATER -TIGHTNESS OF THE ROOF IS THE RESPONSIBILITY OF THE CONTRACTOR. IF AN ASBESTOS SUB -CONTRACTOR IS USED, HE SHALL COORDINATE WITH THE ROOFING CONTRACTOR REGARDING ANY TEMPORARY ROOFING REQUIREMENTS TO ASSURE THAT THE ROOF IS WATER -TIGHT AT ALL TIMES. 16. THE AMOUNT OF ASBESTOS ROOFING MATERIAL REMOVED IN A GIVEN DAY SHALL NOT EXCEED THE AMOUNT OF TEMPORARY AND/OR PERMANENT ROOFING THAT CAN BE REPLACED BY THE END OF THE GIVEN DAY. 17. REFERENCE DRAWING AR02 AND A01 FOR ADDITIONAL INFORMATION AND DETAILS. No.1 Revision 1 Date Seal Project Nome PHI GAMMA DELTA OAKS 21 ROOF REPLACEMENT MICA NEW YORK ADELTA NO Hoer11N/ Enema Nat YakIMO llte 11(17 11.1100 Fee WR,211rIN1 Mut rmilliinglairsarn Wale varadellemlnommora 11111111111 WARNING: THE ALTERATION OF THIS MATERIAL IN ANY WAY, UNLESS DONE UNDER THE DIRECTION OF A COMPARABLE PROFESSIONAL, I.E. ARCHITECT FOR AN ARCHITECT, ENGINEER FOR AN ENGINEER, LANDSCAPE ARCHITECT FOR A LANDSCAPE ARCHITECT OR LICENSED SURVEYOR FOR A LICENSED SURVEYOR, IS A VIOLATION OF THE NEW YORK STATE EDUCATION LAW AND/OR REGULATIONS AND IS A CLASS 'A' MISDEMEANOR. Scale AS SHOWN Project No. 2011.488.004 Date FEBRUARY 13, 2014 Drawing Title ASBESTOS ABATEMENT NOTES AND DETAILS Drawing No. AR01 47-//-* 0 0 0 /\ O O x PLAN �2 SCALE:3/32' = 1'-0°(TROOF R02 SCALE: 3/32" = 1'-0" KEYED NOTES LEGEND: SYMBOL j ASBESTOS CONTAINING SILVER SEALANT/ROOF COATING AND ASSOCIATED SUBSTRATE TO BE REMOVED. THE SILVER SEALANT/ROOF COATING PRESENT ON THE VARIOUS VENT STACKS, CHIMNEY FLASHINGS, AND APPLIED RANDOMLY AS A LOCALIZED REPAIR /MECHANISM IS NOT SHOWN BUT THESE MATERIALS SI1ALL BE REMOVED AT ALL LOCATIONS WHERE PRESENT — APPROXIMATELY 800 SF. ASBESTOS CONTAINING DORMER FLASHING TAR IS NOT SHOWN BUT IS PRESENT ON ALL DORMER WALL FLASHINGS. THIS FLASHING TAR SHALL BE REMOVED AT ALL LOCATIONS WHERE PRESENT — APPROXIMATELY 120 SF TOTAL. REFERENCE DETAIL 1 ON DRAWING Al 2 FOR ADDITIONAL DORMER DEMOLITION INFORMATION. ASBESTOS CONTAINING BLACK CAULK IS NOT SHOWN BUT IS PRESENT AT VARIOUS ROOF PENETRATIONS. THIS CAULK SHALL BE REMOVED AT ALL LOCATIONS WHERE PRESENT — APPROXIMATELY 4 SF TOTAL. 0 0 NORTH 0 0 X O 0 x 8' 0' 8' 16' 24' 32' 40' 11111111 GRAPHIC SCALE: 3/32" = 1'-0" x No.1 Revision 1 Date Seal Project Nome PHI GAMMA DELTA OAKS 21 ROOF REPLACEMENT ITHACA NEW YORK ADELTA NO Mow Ilsel Nonfat I O But rmillidinglaursawn Wale www.dilmelowswa 111111.11111111 WARNING: THE ALTERATION OF THIS MATERIAL IN ANY WAY, UNLESS DONE UNDER THE DIRECTION OF A COMPARABLE PROFESSIONAL, I.E. ARCHITECT FOR AN ARCHITECT, ENGINEER FOR AN ENGINEER, LANDSCAPE ARCHITECT FOR A LANDSCAPE ARCHITECT OR LICENSED SURVEYOR FOR A LICENSED SURVEYOR, IS A VIOLATION OF THE NEW YORK STATE EDUCATION LAW AND/OR REGULATIONS AND IS A CLASS 'A' MISDEMEANOR. Scale AS SHOWN Project No. 2011.488.004 Date FEBRUARY 13, 2104 Drawing Title ASBESTOS ROOFING ABATEMENT PLAN Drawing No. AR02