HomeMy WebLinkAbout28 07 10 - Security Management SystemARCHITECHNOLOGY CORNELL – NCP SECURITY MANAGEMENT SYSTEM STANDARD SPECIFICATIONS 28 07 10 – PAGE 1 OF 6 JUNE 29, 2012 SECTION 28 07 10 SECURITY MANAGEMENT SYSTEMS PART 1 GENERAL 1.1 SUMMARY A. This document includes a general description, functional requirements, operational characteristics, and criteria for the Security Management System (SMS). 1.2 REFERENCES A. The Codes and Regulations listed below form a part of this specification to the extent referenced. Work shall be performed in accordance with the applicable international, federal, state, and local codes or standards current at the commencement of installation. The following list summarizes applicable standards: 1. UL 294, UL 1076, ULC 2. CE 3. FCC – Part 15, Part 68 4. NFPA 70, NEC 5. IEEE, RS 170 variable standard 6. IEEE, NTSC (color camera broadcast) 7. PAL (color camera broadcast, Europe) 8. CCIR (monochrome standard, Europe) 9. Microsoft® Open Database Connectivity (ODBC) interface) 10. ISO Software Coding Standards for C++ and C## 11. RoHS B. Where more than one code or regulation is applicable, the more stringent shall apply. C. Cable installation, identification and termination shall be performed in .addition to the applicable codes above. ARCHITECHNOLOGY CORNELL – NCP SECURITY MANAGEMENT SYSTEM STANDARD SPECIFICATIONS 28 07 10 – PAGE 2 OF 6 JUNE 29, 2012 1.3 SECURITY MANAGEMENT SYSTEM DESCRIPTION A. The Security Management System (SMS) outlined in this section and detailed in Part 2 of this document is the key central component for managing physical security and the bridge between physical and logical security for this project. The system shall provide a variety of integral functions including the ability to regulate access and egress; provide identification credentials; monitor, track and interface alarms; and view, record and store digital surveillance video linked to SMS events. B. The SMS shall utilize a single seamlessly integrated relational database for all functions utilizing a fully multitasking m ultithreading Microsoft Windows 2000/2003 or Windows XP Operating System. The SMS shall be written so that all modules (Access Control, Alarm Monitoring, ID / Credential Management, Visitor Management, Asset Management and Digital Video Management) are developed and built from a unified single 32bit source code set. C. Upgrades or expansion of the SMS to a larger size system in scale shall not require installation of a different and or new SMS application or require the administrator/operator to learn a different and or new interface from the previous version. D. The SMS software shall be written to Microsoft's published standards for User Interface Design, Secure Coding Practices and Database Implementation Guidelines (Microsoft® Open Database Connectivity (ODBC) interface). E. The SMS software shall be written to ISO Standards on Software Development for C++ and C##. F. The SMS shall be able to seamlessly interface with and monitor intelligent system controllers, reader interface modules, I/O panels, burglar alarm panels, burglar alarm panel receivers, biometric devices, personal protection devices, intercom systems, and digital video recorders approved for use by the SMS manufacturer. G. The SMS shall be able to communicate with intelligent system controllers via RS485, RS232, TCPIP/Ethernet and Dialup via Modem. H. All tasks shall be accessible from any compatible client workstation on the network utilizing one or all of the following: 1. Traditional client server architecture 2. Ntier architecture where the SMS shall support the expansion of the system architecture and allow for enduser depl oyment based upon their system architectural needs. The SMS shall allow but not ARCHITECHNOLOGY CORNELL – NCP SECURITY MANAGEMENT SYSTEM STANDARD SPECIFICATIONS 28 07 10 – PAGE 3 OF 6 JUNE 29, 2012 require the separation of the database, application server, web server and client interface. The system shall require that all connections to the database are performed through a trusted link from the client or internet browser interface. 3. Centralized distribution (publishing) of applications using Windows Terminal Server and Citrix on Windows, Unix, Linux or Apple Macintosh based systems through any compatible internet browser application and/or by means of a mobile computing platform using a wearable computer, Tablet PC or PDA device. 1.4 QUALITY ASSURANCE A. Manufacturer Qualifications 1. Manufacturer of the SMS shall be an established organization with referenced and documented experience delivering and maintaining Security Management Systems of equal or higher sophistication and complexity as compared to the system detailed in this specification. 2. SMS Manufacturer’s manufacturing facilities shall be certified ISO 9000:2000 operations, utilize ISO9000:2000 manufac turing procedures and maintain their ISO certifications. 3. SMS Manufacturer shall employ at a minimum the following methods for QA of component and assembly devices. a) Visual inspection of devices shall be performed to verify assembly according to defined procedures. End of line operational tests shall be performed to ensure product functionality has been correctly configured. A system burnin period shall be utilized to screen for early life failures of electronic components. 4. Individual functionality and system level regression testing shall be performed to ensure compliance with product specifications. Single and multiple unit system tests shall be performed to mimic enduser installation configurations. Automated hardware and software testing shall be utilized to evaluate system performance under published operational loads and shall be compared to published system capabilities. B. Bidder Qualifications 1. At the time of the bid, the bidder shall have satisfactorily completed projects similar size, scope and complexity as the system detailed in this specification. The bidder shall furnish written proof of ARCHITECHNOLOGY CORNELL – NCP SECURITY MANAGEMENT SYSTEM STANDARD SPECIFICATIONS 28 07 10 – PAGE 4 OF 6 JUNE 29, 2012 experience from three (3) references and proof of current accreditation/certification by the manufacturer for required training for sales/installation/service of the SMS and associated devices. 2. The bidder shall also be a factory authorized local service organization that shall carry a complete stock of parts and provide maintenance for the SMS and related systems under this contract. Local shall be defined as an area in a 50 mile radius of installed location.) PART 2 PRODUCTS 2.1 MANUFACTURERS A. SMS Hardware and Software 1. Design Make: Best Access (now Stanley) BASIS 2.2 SECURITY MANAGEMENT SYSTEM SERVER (EXISTING) A. All card access components shall be compatible with the Universities existing HeadEnd Database server. The existing ser ver supports Best Access systems’ BASIS software. 2.3 SECURITY MANAGEMENT SYSTEM CLIENT WORKSTATION (EXISTING) A. All card access components shall be compatible with the Universities existing Client workstations. The existing workstations support Best Access systems’ BASIS software. 2.4 SMS SOFTWARE CAPABILITIES A. The SMS Software shall support an unlimited number of card readers, input points, video cameras, door monitoring points, and relay outputs. The SMS database server shall support an unlimited number of cardholders, visitors, and assets limited only by the available memory on the ISC. The database server shall also support an unlimited number of system events and System Operator transactions in the history file limited only by available hard disk space. Client Workstations shall be limited only by the limitations of the operating system server software. 2.5 SMS SOFTWARE FUNCTIONALITY A. Existing CIT SMS Client workstation to allow the following: 1. Local history review of CIT Card History. 2. Receipt of alarms located in the CIT area. ARCHITECHNOLOGY CORNELL – NCP SECURITY MANAGEMENT SYSTEM STANDARD SPECIFICATIONS 28 07 10 – PAGE 5 OF 6 JUNE 29, 2012 PART 3 EXECUTION 3.1 SECURITY MANAGEMENT SYSTEM A. Installation: 1. Install all equipment and materials in accordance with the recommendations of the manufacturer. B. Programming of the system shall include the following tasks: 1. Coordinate all system programming and configuration with the facility’s security maintenance staff. 2. Programming system configuration parameters (hardware and software, reader/circuit numbers, communication parameters). 3. Programming operational parameters such as the card holder database, time zones, access levels and reader definitions. 4. Programming passcodes according to the authorities and functions defined by the Owner. 5. Other system programming tasks required by the Owner. These additional programming requirements shall be coordinated between the Owner, security maintenance staff and the contractor. C. Testing: 1. Operational Testing: The contractor shall perform thorough operational testing and verify that all system components are fully operational. 2. Hardcopy System Printout: The contractor shall submit a hard copy system printout of all components tested and certify 100 percent operation indicating all devices/panels/units have passed the test criteria set forth by the manufacturer. 3.2 COMMISSIONING A. The contractor shall certify completion in writing and schedule the commissioning walkthrough. The contractor shall p rovide all the tools and personnel needed to conduct an efficient commissioning process. 3.3 WARRANTY A. Provide a one year parts and labor warranty on all equipment and software in this section. ARCHITECHNOLOGY CORNELL – NCP SECURITY MANAGEMENT SYSTEM STANDARD SPECIFICATIONS 28 07 10 – PAGE 6 OF 6 JUNE 29, 2012 END OF SECTION ARCHITECHNOLOGY CORNELL – NCP ACCESS CONTROL STANDARD SPECIFICATIONS 28 13 00 – PAGE 1 OF 10 JUNE 29,2012 SECTION 28 13 00 ACCESS CONTROL PART 1 GENERAL 1.1 SUMMARY A. This document includes a general description, functional requirements, operational characteristics, and criteria for Card Access Equipment (CAE). 1.2 REFERENCES A. The Codes and Regulations listed below form a part of this specification to the extent referenced. Work shall be performed in accordance with the applicable international, federal, state, and local codes or standards current at the commencement of installation. The following list summarizes applicable standards: 1. UL 294, UL 1076, ULC 2. CE 3. FCC – Part 15, Part 68 4. NFPA 70, NEC 5. Microsoft® Open Database Connectivity (ODBC) interface) 6. ISO Software Coding Standards for C++ and C## 7. RoHS B. Where more than one code or regulation is applicable, the more stringent shall apply. 1.3 SECURITY MANAGEMENT SYSTEM DESCRIPTION A. The Security Management System (SMS) is outlined in section 28 07 10. This section lists the equipment needed to obtain the card access functionality of the SMS system. 1.4 QUALITY ASSURANCE A. Manufacturer Qualifications 1. Manufacturer of the Card Access Equipment shall be an established organization with referenced and documented experience delivering and maintaining Security Management ARCHITECHNOLOGY CORNELL – NCP ACCESS CONTROL STANDARD SPECIFICATIONS 28 13 00 – PAGE 2 OF 10 JUNE 29,2012 Systems of equal or higher sophistication and complexity as compared to the system detailed in this specification. 2. CAE Manufacturer’s manufacturing facilities shall be certified ISOD 9000:2000 operations, utilize ISOD9000:2000 manufacturing procedures and maintain their ISO certifications. 3. CAE Manufacturer shall employ at a minimum the following methods for QA of component and assembly devices. a) Visual inspection of devices shall be performed to verify assembly according to defined procedures. End of line operational tests shall be performed to ensure product functionality has been correctly configured. A system burnDin period shall be utilized to screen for early life failures of electronic components. 4. Individual functionality and system level regression testing shall be performed to ensure compliance with product specifications. Single and multiple unit system tests shall be performed to mimic endDuser installation configurations. Automated hardware and software testing shall be utilized to evaluate system performance under published operational loads and shall be compared to published system capabilities. B. Bidder Qualifications (Stanley Security Systems currently maintains the existing card access systems for CIT) 1. At the time of the bid, the bidder shall have satisfactorily completed projects similar size, scope and complexity as the system detailed in this specification. The bidder shall furnish written proof of experience from three (3) references and proof of current accreditation/certification by the manufacturer for required training for sales/installation/service of the SMS and associated devices. 2. The bidder shall also be a factory authorized local service organization that shall carry a complete stock of parts and provide maintenance for the SMS and related systems under this contract. Local shall be defined as an area in a (**X) mile radius of installed location.) PART 2 PRODUCTS 2.1 MANUFACTURERS A. SMS Field Hardware: ARCHITECHNOLOGY CORNELL – NCP ACCESS CONTROL STANDARD SPECIFICATIONS 28 13 00 – PAGE 3 OF 10 JUNE 29,2012 1. Best Access B. Card Readers 1. HID 2.2 INTELLIGENT SYSTEM CONTROLLER (ISC) A. The Intelligent System Controller (ISC) shall link the SMS Software to all “downDstream” field hardware components (Reader Interface Modules, Input Control Modules and Output Control Modules). The ISC shall provide full distributed processing of access control / Alarm Monitoring rules and operations. A fully loaded and configured ISC with shall respond in less than oneDhalf (0.5) second to grant or deny access to cardholder. B. The ISC shall continue to function normally (standDalone) in the event that it loses communication with the SMS software. While in this offDline state, the ISC shall make access granted/denied decisions and maintain a log of the events that have occurred. Events shall be stored in local memory, and then uploaded automatically to the SMS database after communication has been restored. C. In addition, the ISC shall incorporate the following features: 1. UL 294, ULC, and CE Certified 2. Support for Host Communications Speed of 38,400 bps 3. Support for Direct Connect, Remote Dial Up, or Local Area Network (LAN) Connection 4. Support for up to .5 MB of OnDBoard Memory 5. LAN Support shall utilize RJ45 (10/100baseT) Ethernet Interface or Token Ring 4 MB connectivity 6. Flash Memory for real time program updates and overall host communications 7. Support for four 2 wire downstream ports, two 4 wire downstream ports, or combination one 4 wire downstream port and two 2 wire downstream ports. Downstream ports shall be for connecting card readers and data gathering and output control panels via RSD485 multiDdrop wiring configuration 8. Memory storage of up to 12,500 cardholders with 4 MB memory expansion. ARCHITECHNOLOGY CORNELL – NCP ACCESS CONTROL STANDARD SPECIFICATIONS 28 13 00 – PAGE 4 OF 10 JUNE 29,2012 9. Initial base memory download between ISC with standard memory from the SMS shall require no more than ten (10) seconds 10. Support for up to 16 devices consisting of RIMs, ICMs, and OCMs in any combination desired with a maximum of 8 I/OCM devices per ISC 11. Support of multiple card technologies 12. Supervised Communications between ISC and SMS Software 13. AES 128 bit Symmetrical Block Encryption conforming to the FIPSD 197 standard between ISC and SMS Software communications driver. 14. Multi – drop support for up to eight ISCs per SMS communications port 15. Support of up to eight card formats and facility codes 16. Support for SEIWG card formats 17. RSD485 Full Duplex, UL 1076 Grade AA communication channel to the SMS headDend 18. Integration to other manufacturer’s card readers 19. Uninterruptible Power Supply (UPS) with battery backup for 2 hours 20. 32Dbit Microprocessor 21. Biometric Interface Support 22. An ISC downstream serial port shall multiDdrop 16 access control field hardware devices using an RSD485 UL 1076 Grade A communication format allowing a distance of 4,000 feet using Belden 9842 cable or equivalent 23. 12 VAC or 12 VDC input power 24. Issue Code Support for both Magnetic and Wiegand Card Formats 25. Individual Shunt Times (ADA Requirement) 26. Up to Nine Digit PIN Codes 27. Downstream serial RSD232 device support 28. Status LEDs for normal component and communication status ARCHITECHNOLOGY CORNELL – NCP ACCESS CONTROL STANDARD SPECIFICATIONS 28 13 00 – PAGE 5 OF 10 JUNE 29,2012 29. RoHS Compliance 30. Support for RSD485 over CAT 5, 6e cable 2.3 INPUT CONTROL MODULE (ICM) A. The Input Control Module shall provide 16 UL 1076 Grade B, A or AA alarm input zones and monitor / report line fault conditions, alarm conditions, power faults and tampers. Status LEDs shall provide information about the sixteen alarm zone inputs, cabinet tamper, and power fault. B. In addition, the ICM shall incorporate the following features: 1. UL 294, ULC, and CE Certified 2. Alarm contact status scanning at up to 180 times per second for each zone 3. Eight configuration DIP switches to assign unit addresses and communications speed 4. Elevator control support for 128 floors 5. Variable resistor values for line supervision 6. A low power CMOS microprocessor 7. Filtered data for noise rejection to prevent false alarms 8. Up to 16 Grade B, A, or AA Supervised Inputs in any Combination 9. 12 or 24 VDC Input Power 10. 2 Form C 5A, 30 VDC Contacts for load switching 11. 2 dedicated inputs for tamper and power status 12. RoHS Compliance 13. Support for RSD485 over CAT 5, 6e cable 2.4 OUTPUT CONTROL MODULE (OCM) A. The Output Control Modules shall provide 16 FormDC 5A 30 VDC relay contacts for load switching. The relays shall be configurable for failDsafe or failDsecure operation. Each relay shall support “On” “Off” and “Pulse” 1. 12 or 24 VDC input power ARCHITECHNOLOGY CORNELL – NCP ACCESS CONTROL STANDARD SPECIFICATIONS 28 13 00 – PAGE 6 OF 10 JUNE 29,2012 2. Two dedicated digital inputs for tamper and power failure status 3. RSD485 communications, multiDdropped (2Dwire or 4Dwire RSD485) 4. Up to 16 OCMs per Intelligent System Controller 5. Onboard termination jumpers 6. DIP switch selectable addressing 7. Status LEDs for communication to the host, heartbeat and relay status 8. Elevator control, support for 64 floors 9. RoHS Compliance 10. Support for RSD485 over CAT 5, 6e cable 2.5 SINGLE READER INTERFACE MODULE (SRI) A. The SRI shall provide an interface between the ISC and authentication devices. The SRI must operate with any authentication device that produces a standard Wiegand, Data 1 / Data 0) or Clock and Data communication output. B. In addition the SRI shall incorporate the following features: 1. 12 or 24 VDC power supply 2. Reader communications (Clock/Data or Wiegand Data1/Data0) D more than 150 different readers approved for use 3. Two FormDC relay outputs (5 A Door Strike and 1 A Aux relays) 4. Up to 16 different card formats (8 card and 8 asset) 5. Issue code support for Magnetic and Wiegand formats 6. Door contact Open or Closed, Supervised or NonDsupervised 7. REX pushDbutton monitor D Supervised or NonDsupervised 8. Strike Control output 9. Dedicated tamper and power failure circuits 10. Bicolor or two wire status LED support ARCHITECHNOLOGY CORNELL – NCP ACCESS CONTROL STANDARD SPECIFICATIONS 28 13 00 – PAGE 7 OF 10 JUNE 29,2012 11. Beeper control 12. Support for offline reader access mode 13. Elevator control, support for 64 floors 14. UL 294 listed and CE approved 15. RoHS Compliance 16. Support for RSD485 over CAT 5, 6e cable 2.6 DUAL READER INTERFACE MODULE (DRI) A. The DRI shall provide a dual interface between the ISC and authentication devices. The DRI must operate with any authentication device that produces a standard Wiegand (Data 1 / Data 0 or Clock and Data) communication output. B. In addition the DRI shall incorporate the following features: 1. 12 or 24 VDC power supply 2. Reader communications (Clock/Data or Wiegand Data1/Data0) D more than 150 different readers approved for use 3. Six FormDC 5 A at 30 VDC relay outputs 4. Up to 16 different formats (8 card and 8 asset) 5. Issue code support for Magnetic and Wiegand formats 6. Door contact supervision (Open/Closed) 7. REX pushDbutton monitor 8. Strike Control output 9. BiDcolor status LED support and 2Dwire LED support 10. Beeper control 11. Dedicated tamper and power failure circuits 12. Support for offline reader access mode 13. Onboard jumpers for termination 14. Onboard jumpers for 5 VDC or 12 VDC reader support ARCHITECHNOLOGY CORNELL – NCP ACCESS CONTROL STANDARD SPECIFICATIONS 28 13 00 – PAGE 8 OF 10 JUNE 29,2012 15. Elevator control, native support for 6 floors 16. DIP switch selectable addressing 17. UL 294 listed and CE approved 18. RoHS Compliance 19. Support for RSD485 over CAT 5, 6e cable 2.7 CARDS A. The system will be operated with the University’s’ existing HID compatible proximity cards. 2.8 CARD READER LOCK (CRL) A. HID compatible 125Khz proximity reader B. Compatible with cards, reader interface module and SMS software C. Green/red – valid/void leds D. Mortise lock E. New Locks shall be Seargent Lever (LL) F. Locks shall be storeroom locks (04) G. Shall accommodate Best small format 7 pin interchangeable core prefix 70 for Best. H. Locks shall be fail secure I. Tamper resistant mounting J. Integral request to exit door position switch and solenoid controlled lock K. Read range 6” L. Shall be installed by a Harmony certified installer M. Sargent Harmony series 2.9 DOOR CONTACTS (DC) A. Integral to CRL on new doors B. Flush mount ARCHITECHNOLOGY CORNELL – NCP ACCESS CONTROL STANDARD SPECIFICATIONS 28 13 00 – PAGE 9 OF 10 JUNE 29,2012 C. Form c contact D. Magnetic strength suitable for metal doors and frames. E. Door Contacts shall be Sentrol 1078 2.10 MORTISE MOUNT ELECTRONIC EPT (NEW DOORS) A. Used for flush mount wired connections to the Card Reader Lock on new doors. B. 12 conducter #22 awg with Electrolinx connectors. C. Magnetic strength suitable for metal doors and frames. D. Design Make: Securitron ELDCEPT Power Transfer 2.11 SURFACE MOUNT ELECTRONIC EPT (EXISTING DOORS) A. Used for surface mount wired connections to the Card Reader Lock on existing doors. B. Use preDterminated quick connect (McKinney ElectroLynx) plugDandDplay kit with 15’ of cable Specify Keedex part #: KDDL38A24 door to frame power transfer flex conduit with box at each end. Cut connectors off one end of ElectroLynx cable, fish raw cable end from the lock to the ceiling space and leave coil for Stanley Technician to connect to power. PART 3 EXECUTION 3.1 SECURITY MANAGEMENT SYSTEM A. Installation: 1. Install all equipment and materials in accordance with the recommendations of the manufacturer. 2. Provide all wiring as required by the manufacturer. Provide plenum rated cable as required. B. Programming of the system shall include the following tasks: 1. Coordinate all system programming and configuration with the facility’s security maintenance staff. 2. Programming system configuration parameters (hardware and software, reader/circuit numbers, communication parameters). ARCHITECHNOLOGY CORNELL – NCP ACCESS CONTROL STANDARD SPECIFICATIONS 28 13 00 – PAGE 10 OF 10 JUNE 29,2012 3. Programming operational parameters such as the card holder database, time zones, access levels and reader definitions. 4. Programming passcodes according to the authorities and functions defined by the Owner. 5. Other system programming tasks required by the Owner. These additional programming requirements shall be coordinated between the Owner, security maintenance staff and the contractor. C. Testing: 1. Operational Testing: The contractor shall perform thorough operational testing and verify that all system components re fully operational. 2. HardDcopy System Printout: The contractor shall submit a hardD copy system printout of all components tested and certify 100 percent operation indicating all devices/panels/units have passed the test criteria set forth by the manufacturer. 3.2 CARD READER A. Install card readers in locations shown on plans. Install readers past the swing of the door. B. Provide surface mount back boxes only where needed. Where possible provide flush mount back boxes that can be covered by the card reader. When needed the door jam or a hallow wall can be used as the junction point for the card reader connections. 3.3 COMMISSIONING A. The contractor shall certify completion in writing and schedule the commissioning walkDthrough. The contractor shall provide all the tools and personnel needed to conduct an efficient commissioning process. 3.4 WARRANTY A. Provide a 1 year parts and labor warranty for all equipment and software provided in this section. END OF SECTION Fax: 585.424.4239 115 METRO PARK ROCHESTER, NY 14623 www.archi-technology.com PHONE: 585.424.1952 ISSUE DATE: PROJECT MANAGER: DRAWN BY: CHECKED BY: AT-07841302 CONCRETE FLOOR FIRESTOP PENETRATION DETAIL (CONDUIT SLEEVE) AT STANDARD DETAILS Fax: 585.424.4239 115 METRO PARK ROCHESTER, NY 14623 www.archi-technology.com PHONE: 585.424.1952 ISSUE DATE: PROJECT MANAGER: DRAWN BY: CHECKED BY: AT-07841303 CONCRETE FLOOR FIRESTOP PENETRATION DETAIL (CONTINUOUS CONDUIT) AT STANDARD DETAILS Fax: 585.424.4239 115 METRO PARK ROCHESTER, NY 14623 www.archi-technology.com PHONE: 585.424.1952 ISSUE DATE: PROJECT MANAGER: DRAWN BY: CHECKED BY: AT-27052801 WIRE MESH CABLE TRAY - CEILING MOUNT INSTALLATION AT STANDARD DETAILS Fax: 585.424.4239 115 METRO PARK ROCHESTER, NY 14623 www.archi-technology.com PHONE: 585.424.1952 ISSUE DATE: PROJECT MANAGER: DRAWN BY: CHECKED BY: AT-27052802 CABLE TRAY - WALL PENETRATION AT STANDARD DETAILS Fax: 585.424.4239 115 METRO PARK ROCHESTER, NY 14623 www.archi-technology.com PHONE: 585.424.1952 ISSUE DATE: PROJECT MANAGER: DRAWN BY: CHECKED BY: AT-27052803 WIRE MESH CABLE TRAY - SECODARY CONDUIT INSTALLATION AT STANDARD DETAILS Fax: 585.424.4239 115 METRO PARK ROCHESTER, NY 14623 www.archi-technology.com PHONE: 585.424.1952 ISSUE DATE: PROJECT MANAGER: DRAWN BY: CHECKED BY: AT-27052804 WIRE MESH CABLE TRAY - BACKBONE CONDUIT INSTALLATION AT STANDARD DETAILS Fax: 585.424.4239 115 METRO PARK ROCHESTER, NY 14623 www.archi-technology.com PHONE: 585.424.1952 ISSUE DATE: PROJECT MANAGER: DRAWN BY: CHECKED BY: AT-27052805 TYPICAL PRIMARY/BACKBONE PATHWAY PULLBOX INSTALLATION DETAIL AT STANDARD DETAILS Fax: 585.424.4239 115 METRO PARK ROCHESTER, NY 14623 www.archi-technology.com PHONE: 585.424.1952 ISSUE DATE: PROJECT MANAGER: DRAWN BY: CHECKED BY: AT-27052806 PULLBOX PB-M AND PB-L MOUNTING DETAIL FOR INACCESSIBLE CEILINGS AT STANDARD DETAILS Fax: 585.424.4239 115 METRO PARK ROCHESTER, NY 14623 www.archi-technology.com PHONE: 585.424.1952 ISSUE DATE: PROJECT MANAGER: DRAWN BY: CHECKED BY: AT-27052807 CABLE TRAY TO BOX / FLOOR CONNECTOR FOR A TR AT STANDARD DETAILS Fax: 585.424.4239 115 METRO PARK ROCHESTER, NY 14623 www.archi-technology.com PHONE: 585.424.1952 ISSUE DATE: PROJECT MANAGER: DRAWN BY: CHECKED BY: AT-27052808 FULLY ENCLOSED CABLE TRAY CONNECTION DETAIL AT STANDARD DETAILS Fax: 585.424.4239 115 METRO PARK ROCHESTER, NY 14623 www.archi-technology.com PHONE: 585.424.1952 ISSUE DATE: PROJECT MANAGER: DRAWN BY: CHECKED BY: AT-27052809 CONDUIT TO FULLY ENCLOSED CABLE TRAY CONNECTION DETAIL AT STANDARD DETAILS Fax: 585.424.4239 115 METRO PARK ROCHESTER, NY 14623 www.archi-technology.com PHONE: 585.424.1952 ISSUE DATE: PROJECT MANAGER: DRAWN BY: CHECKED BY: AT-27052810 MISC. FULLY ENCLOSED CABLE TRAY / RUNWAY ENDS DETAIL AT STANDARD DETAILS Fax: 585.424.4239 115 METRO PARK ROCHESTER, NY 14623 www.archi-technology.com PHONE: 585.424.1952 ISSUE DATE: PROJECT MANAGER: DRAWN BY: CHECKED BY: AT-27052811 4" CONDUIT TO FULLY ENCLOSED CABLE TRAY CONNECTION DETAIL AT STANDARD DETAILS Fax: 585.424.4239 115 METRO PARK ROCHESTER, NY 14623 www.archi-technology.com PHONE: 585.424.1952 ISSUE DATE: PROJECT MANAGER: DRAWN BY: CHECKED BY: AT-27052812 CONDUIT TO FULLY ENCLOSED CABLE TRAY CONNECTION DETAIL AT STANDARD DETAILS Fax: 585.424.4239 115 METRO PARK ROCHESTER, NY 14623 www.archi-technology.com PHONE: 585.424.1952 ISSUE DATE: PROJECT MANAGER: DRAWN BY: CHECKED BY: AT-27052813 4" CONDUIT TO FULLY ENCLOSED CABLE TRAY CONNECTION DETAIL AT STANDARD DETAILS Fax: 585.424.4239 115 METRO PARK ROCHESTER, NY 14623 www.archi-technology.com PHONE: 585.424.1952 ISSUE DATE: PROJECT MANAGER: DRAWN BY: CHECKED BY: AT-27052814 4" CONDUIT TO FULLY ENCLOSED CABLE TRAY CONNECTION DETAIL AT STANDARD DETAILS Fax: 585.424.4239 115 METRO PARK ROCHESTER, NY 14623 www.archi-technology.com PHONE: 585.424.1952 ISSUE DATE: PROJECT MANAGER: DRAWN BY: CHECKED BY: AT-27052815 VERTICAL TO HORIZONTAL FULLY ENCLOSED CABLE TRAY DETAIL AT STANDARD DETAILS Fax: 585.424.4239 115 METRO PARK ROCHESTER, NY 14623 www.archi-technology.com PHONE: 585.424.1952 ISSUE DATE: PROJECT MANAGER: DRAWN BY: CHECKED BY: AT-27052816 FW,JT - FISH WALL, J-HOOK TO CABLE TRAY AT STANDARD DETAILS Fax: 585.424.4239 115 METRO PARK ROCHESTER, NY 14623 www.archi-technology.com PHONE: 585.424.1952 ISSUE DATE: PROJECT MANAGER: DRAWN BY: CHECKED BY: AT-27052817 SH,JT - SURFACE RACEWAY TO HALLWAY, J-HOOK TO CABLE TRAY AT STANDARD DETAILS Fax: 585.424.4239 115 METRO PARK ROCHESTER, NY 14623 www.archi-technology.com PHONE: 585.424.1952 ISSUE DATE: PROJECT MANAGER: DRAWN BY: CHECKED BY: AT-27052818 SC,CP - SURFACE RACEWAY TO CEILING, CONDUIT TO PULLBOX AT STANDARD DETAILS Fax: 585.424.4239 115 METRO PARK ROCHESTER, NY 14623 www.archi-technology.com PHONE: 585.424.1952 ISSUE DATE: PROJECT MANAGER: DRAWN BY: CHECKED BY: AT-27052820 SC,CP - SURFACE RACEWAY TO CEILING, CONDUIT TO PULLBOX AT STANDARD DETAILS Fax: 585.424.4239 115 METRO PARK ROCHESTER, NY 14623 www.archi-technology.com PHONE: 585.424.1952 ISSUE DATE: PROJECT MANAGER: DRAWN BY: CHECKED BY: AT-27052821 SH,CP - SURFACE RACEWAY TO HALLWAY, CONDUIT TO PULLBOX AT STANDARD DETAILS Fax: 585.424.4239 115 METRO PARK ROCHESTER, NY 14623 www.archi-technology.com PHONE: 585.424.1952 ISSUE DATE: PROJECT MANAGER: DRAWN BY: CHECKED BY: AT-27052822 SH - SURFACE RACEWAY TO HALLWAY AT STANDARD DETAILS Fax: 585.424.4239 115 METRO PARK ROCHESTER, NY 14623 www.archi-technology.com PHONE: 585.424.1952 ISSUE DATE: PROJECT MANAGER: DRAWN BY: CHECKED BY: AT-27052822 SH - SURFACE RACEWAY TO HALLWAY AT STANDARD DETAILS Fax: 585.424.4239 115 METRO PARK ROCHESTER, NY 14623 www.archi-technology.com PHONE: 585.424.1952 ISSUE DATE: PROJECT MANAGER: DRAWN BY: CHECKED BY: AT-27052824 SC - SURFACE RACEWAY TO HALLWAY DETAIL AT STANDARD DETAILS Fax: 585.424.4239 115 METRO PARK ROCHESTER, NY 14623 www.archi-technology.com PHONE: 585.424.1952 ISSUE DATE: PROJECT MANAGER: DRAWN BY: CHECKED BY: AT-27052825 SH - SURFACE RACEWAY TO HALLWAY DETAIL AT STANDARD DETAILS Fax: 585.424.4239 115 METRO PARK ROCHESTER, NY 14623 www.archi-technology.com PHONE: 585.424.1952 ISSUE DATE: PROJECT MANAGER: DRAWN BY: CHECKED BY: AT-27052826 TYPICAL SR-2 SURFACE RACEWAY INSTALLATION AT STANDARD DETAILS Fax: 585.424.4239 115 METRO PARK ROCHESTER, NY 14623 www.archi-technology.com PHONE: 585.424.1952 ISSUE DATE: PROJECT MANAGER: DRAWN BY: CHECKED BY: AT-27052827 TYPICAL ETR SR-4D DIVIDED SURFACE RACEWAY OUTLET INSTALLATION AT STANDARD DETAILS Fax: 585.424.4239 115 METRO PARK ROCHESTER, NY 14623 www.archi-technology.com PHONE: 585.424.1952 ISSUE DATE: PROJECT MANAGER: DRAWN BY: CHECKED BY: AT-27052828 TYPICAL ETR SR-4D DIVIDED SURFACE RACEWAY OUTLET INSTALLATION :(;7(16,21 AT STANDARD DETAILS Fax: 585.424.4239 115 METRO PARK ROCHESTER, NY 14623 www.archi-technology.com PHONE: 585.424.1952 ISSUE DATE: PROJECT MANAGER: DRAWN BY: CHECKED BY: AT-27052829 TYPICAL ETR SR-3 SURFACE RACEWAY OUTLET INSTLLATION AT STANDARD DETAILS Fax: 585.424.4239 115 METRO PARK ROCHESTER, NY 14623 www.archi-technology.com PHONE: 585.424.1952 ISSUE DATE: PROJECT MANAGER: DRAWN BY: CHECKED BY: AT-27052830 TYPICAL SURFACE RACEWAY BRIDGE INSTALLATION AT STANDARD DETAILS Fax: 585.424.4239 115 METRO PARK ROCHESTER, NY 14623 www.archi-technology.com PHONE: 585.424.1952 ISSUE DATE: PROJECT MANAGER: DRAWN BY: CHECKED BY: AT-27052831 TYPICAL RECESSED OR SURFACE MOUNTED CONDUIT INSTALLATION AT STANDARD DETAILS Fax: 585.424.4239 115 METRO PARK ROCHESTER, NY 14623 www.archi-technology.com PHONE: 585.424.1952 ISSUE DATE: PROJECT MANAGER: DRAWN BY: CHECKED BY: AT-27052832 TYPICAL HORIZONTAL CONDUIT/JUNCTION BOX INSTALLATION AT STANDARD DETAILS Fax: 585.424.4239 115 METRO PARK ROCHESTER, NY 14623 www.archi-technology.com PHONE: 585.424.1952 ISSUE DATE: PROJECT MANAGER: DRAWN BY: CHECKED BY: AT-27052833 TYPICAL SURFACE CONDUIT INSTALLATION AT STANDARD DETAILS Fax: 585.424.4239 115 METRO PARK ROCHESTER, NY 14623 www.archi-technology.com PHONE: 585.424.1952 ISSUE DATE: PROJECT MANAGER: DRAWN BY: CHECKED BY: AT-27052834 TYPICAL SURFACE CONDUIT INSTALLATION AT STANDARD DETAILS Fax: 585.424.4239 115 METRO PARK ROCHESTER, NY 14623 www.archi-technology.com PHONE: 585.424.1952 ISSUE DATE: PROJECT MANAGER: DRAWN BY: CHECKED BY: AT-27052835 TYPICAL RECESSED BACKBOX / CONDUIT DETAILS AT STANDARD DETAILS Fax: 585.424.4239 115 METRO PARK ROCHESTER, NY 14623 www.archi-technology.com PHONE: 585.424.1952 ISSUE DATE: PROJECT MANAGER: DRAWN BY: CHECKED BY: AT-27052836 RECESSED CONDUIT VIA (2) 0.75" FLEX CONDUITS DETAIL AT STANDARD DETAILS Fax: 585.424.4239 115 METRO PARK ROCHESTER, NY 14623 www.archi-technology.com PHONE: 585.424.1952 ISSUE DATE: PROJECT MANAGER: DRAWN BY: CHECKED BY: AT-27052837 COMMUNICATIONS POWER POLE DETAIL AT STANDARD DETAILS Fax: 585.424.4239 115 METRO PARK ROCHESTER, NY 14623 www.archi-technology.com PHONE: 585.424.1952 ISSUE DATE: PROJECT MANAGER: DRAWN BY: CHECKED BY: AT-27052839 TYPICAL WAP INSTALLATION (OPEN CEILING) AT STANDARD DETAILS Fax: 585.424.4239 115 METRO PARK ROCHESTER, NY 14623 www.archi-technology.com PHONE: 585.424.1952 ISSUE DATE: PROJECT MANAGER: DRAWN BY: CHECKED BY: AT-27052840 WIRELESS CEILING ENCLOSURE DETAIL AT STANDARD DETAILS Fax: 585.424.4239 115 METRO PARK ROCHESTER, NY 14623 www.archi-technology.com PHONE: 585.424.1952 ISSUE DATE: PROJECT MANAGER: DRAWN BY: CHECKED BY: AT-27052842 TYPICAL WAP INSTALLATION (WALL MOUNT) AT STANDARD DETAILS Fax: 585.424.4239 115 METRO PARK ROCHESTER, NY 14623 www.archi-technology.com PHONE: 585.424.1952 ISSUE DATE: PROJECT MANAGER: DRAWN BY: CHECKED BY: AT-27052845 TYPICAL WALL MOUNTED TELEPHONE OUTLET INSTALLATION (SR-2 OR RECESSED CONDUIT) AT STANDARD DETAILS Fax: 585.424.4239 115 METRO PARK ROCHESTER, NY 14623 www.archi-technology.com PHONE: 585.424.1952 ISSUE DATE: PROJECT MANAGER: DRAWN BY: CHECKED BY: AT-27052846 TYPICAL WALL MOUNTED TELEPHONE OUTLET - NEW WORK RECESSED INSTALLATION AT STANDARD DETAILS Fax: 585.424.4239 115 METRO PARK ROCHESTER, NY 14623 www.archi-technology.com PHONE: 585.424.1952 ISSUE DATE: PROJECT MANAGER: DRAWN BY: CHECKED BY: AT-27052847 TYPICAL ELEVATOR / ENERGY MANAGEMENT CONNECTION AT STANDARD DETAILS Fax: 585.424.4239 115 METRO PARK ROCHESTER, NY 14623 www.archi-technology.com PHONE: 585.424.1952 ISSUE DATE: PROJECT MANAGER: DRAWN BY: CHECKED BY: AT-27052849 CABLE TRAY - EZ-PATH INSTALLATION AT STANDARD DETAILS Fax: 585.424.4239 115 METRO PARK ROCHESTER, NY 14623 www.archi-technology.com PHONE: 585.424.1952 ISSUE DATE: PROJECT MANAGER: DRAWN BY: CHECKED BY: AT-27052850 FW (FISH WALL) OUTLET INSTALLATION AT STANDARD DETAILS