HomeMy WebLinkAboutBiotech ECI Pneumatic ReplacemntVictor, NY 14564 Logical Control Solutions T: 585.424 .5340 F: 585.424.5369 Project Number: Drawing Designation: Project Name: Drawing Date: 18-060 Submittal 18-060 Biotech ECI Pneumatic Replacemnt 9/27/2018 Page Manufacturer Part Number Part Description 2 Automated Logic ZN253 Zone Controller, 2DO, 5UI , 3AO 4 Automated Logic ZN551 Zone Controller, 5DO, 5UI , 1AO 6 Automated Logic ZS2P-ALC ZS2 Pro Space Temp Sensor , Rnet, LCD, SP Adj, Ovrd 6 Automated Logic ZS2P-M-ALC ZS2 Pro Space Temp & Motion, Rnet, LCD, SP Adj. Ovrd 8 BAPI ALC/10 K-2-D-8"-BB4 Duct, 8" Insertion, BAPI Box 4 IP44 9 Belimo B217 Control Valve 9 Belimo B211 Control Valve 10 Belimo TFRX24 -SR Valve Actuator 12 Belimo TR24 -SR US Valve Actuator 14 Functional Devices PSH300A Enclosed 300VA Pwr Supply, 3x100VA Circuits 15 Functional Devices PSH500A Enclosed 500VA Pwr Supply, 5x100VA Circuits 16 Functional Devices RIB2401C Enclosed Relay, 10 A, SPDT, 24 Vac/dc/120Vac Coil 17 Functional Devices RIBXKTV5-10 0-10 Amp, 0-5VDC, Solid Core 18 Setra CSCGA2125R1 Current Switch w/Relay, Split Core, Adj. 1.25 -135 Amp, 10 A@260 VAC, 5A@30 VDC, SPST 22 Setra MRGPA Field Selectable 0.5" to 5.0"; Outputs(0-5Vdc, 0- 10 Vdc, 4-20 mA) Duct Probe, 1/2' Conduit 1150 Roberts Boulevard Kennesaw, Georgia 30144 770/429-3000 Fax 770/429-3001 www.automatedlogic.com CSZN253rev9 ZN253 Zone Controller Automated Logic’s ZN253 provides unprecedented power and f lexibility through fully programmable networked controllers. The ZN253 controllers connect to the Building Automation System (BAS) network using BACnet over ARCNET 156 Kbps or MS/TP. The ZN253 supports a line of RS room sensors using its Rnet port. Key Features and Benefits • Powerful zone controller for VAV, heat pump, unit ventilator and other packaged HV-ac applications. • Native BACnet communications to f ield devices over a high speed ARCNET 156 Kbps or BACnet MS/TP network. • Uses a high speed 16-bit microprocessor with 1 MByte Flash memory and 512 KByte of RAM for unparalleled programmability. Firmware upgrades can be downloaded remotely – no chip replacement necessary. • The ZN253 is part of a full line of ZN controllers which include a variety of Universal Inputs, Binary Outputs and 0-10 V-dc Analog Outputs. Other ZN models with built-in f low sensors and/or integral damper actuators are available as well as optional single/dual air f low sensors for pressure independent VAV applications. • Rnet port supports Automated Logic’s line of RS room sensors and provides local access to the system. • The ZN253 controller is fully graphically programmable and offers full peer-to-peer communications with other ZN line, ME line or SE line controllers. Graphical programs are universally understood and provide self-documenting control sequences. • An extensive library of pre-engineered control routines provides proven solutions for most zone control applications. Custom programs can be easily written in EIKON®-LogicBuilder, ALC’s legendary graphic programming language. • Compact and rugged plastic enclosure for easy mounting. Automated Logic Corporation . 1150 Roberts Boulevard . Kennesaw, Georgia 30144 . 770/429-3000 . Fax 770/429-3001 . www.automatedlogic.com © 2012, Automated Logic Corporation. Automated Logic, the Automated Logic logo, EIKON and WebCTRL are registered trademarks of Automated Logic Corporation. BACnet is a registered trademark of ASHRAE. All other trademarks are the property of their respective owners. Specifications are subject to change without prior notice. BACnet Support: Conforms to the Advanced Application Controller (B-AAC) Standard Device Profile as defined in BACnet 135-2001 Annex L. Communication: The following ports are available on the ZN253 module: EIA-485 port for ARCNET 156 Kbps or MS/TP (9600 bps – 76.8 Kbps). Local access port for system start-up and troubleshooting. Rnet port for RS room sensors, RS Standard and RS Pro – the Rnet port supports up to four RS Standards and one RS Pro sensor for averaging or high/low select control. NOTE: Local operator interface (BACview ®) is not supported. LogiStat port for LogiStat and LogiStat Plus. Two Analog Inputs are used by the LogiStat port. Binary Outputs: Two binary outputs, relay contact rated at 1A max @ 24 V-ac, conf igured normally open. Universal Inputs: Five inputs with 10 bit A/D resolution for dry contact or Type 2 thermistors. NOTE: Inputs 1 and 2 are also configurable for 0 - 5 V-dc. Inputs 4 and 5 are taken when a LogiStat sensor is connected – these inputs are available if RS sensors are used. Analog Outputs: Three analog outputs, 0-10 V-dc with 8-bit resolution. Microprocessor: High speed 16-bit microprocessor with ARCNET communication co-processor. Memory: 512 KByte non-volatile battery-backed RAM, 1 MByte Flash memory, 16-bit memory bus. (Shelf life of the battery is 10 years with 10,000 hours of continuous operation.) Status Indicators: LED status indicators for EIA-485 communication, running, error, power and all binary outputs. Module Addressing: Rotary dip switches for intuitive network addressing of modules. Protection: Built-in surge and transient protection circuitry for power, communications, inputs and outputs. Listed by: UL916 (Canadian Std C22.2 No. 205-M1983), CE, FCC Part 15 – Subpart B – Class A Environmental Operating Range: 0ºF to 130ºF (-17.8ºC to 54.4ºC); 10% to 90% relative humidity, non-condensing. NOTE: Control modules must be installed within the building. Power Requirements: 24 V-ac ± 10%, 26 V-dc (25 V min, 30 V max), 50 to 60Hz, 12 VA Physical: Rugged GE C2950 Cycoloy plastic. Weight: 0.6 lb. (0.27 kg) Dimensions:Overall Width: 5-1/16” (129mm) Height: 5-11/16” (144mm) Depth: 1-1/2” (38mm) min. panel depth Mounting* Two mounting holes center line as at left with 5-5/16” (135mm) spacing (height). *For indoor use only.ZN253 Mounting hole spacing 5-5/16”. ZN253 Specif ications LGR Router or ME-LGR Router/Controller To Third Party Equipment BACnet®/IP, 100Base-T Ethernet Ethernet, ARCNET, EIA-485, EIA-232 XML/SOAP HTML/HTTP BACnet MS/TP, ARCNET WML/WAP WML/WAP HTML/HTTP Internet Server Web Browser CellPhone Web Browser PDA ME line Controller SE lineController Room Sensor Room Sensor ZN lineController Room Sensor Room Controller ME812u-EController Enterprise System CSZN253rev9 ZN551 Zone Controller Automated Logic’s ZN551 provides unprecedented power and flexibility through fully programmable networked controllers. The ZN551 controllers connect to the Building Automation System (BAS) network using BACnet over ARCNET 156 Kbps or MS/TP. The ZN551 supports a line of RS room sensors using Rnet port. Key Features and Benefits • Powerful zone controller for VAV, heat pump, unit ventilator and other packaged HV-ac applications. • Native BACnet communications to field devices over a high speed ARCNET 156 Kbps or BACnet MS/TP network. • Uses a high speed 16-bit microprocessor with 1 MByte Flash memory and 512 KByte of RAM for unparalleled programmability. Firmware upgrades can be downloaded remotely – no chip replacement necessary. • The ZN551 is part of a full line of ZN controllers which include a variety of Universal Inputs, Binary Outputs and 0-10V-dc Analog Outputs. Other ZN models with built-in flow sensors and/or integral damper actuators are available as well as optional single/dual air flow sensors for pressure independent VAV applications. • Rnet port supports Automated Logic’s line of RS room sensors and provides local access to the system. • The ZN551 controller is fully graphically programmable and offers full peer-to-peer communications with other ZN line, ME line or SE line controllers. Graphical programs are universally understood and provide self- documenting control sequences. • An extensive library of pre-engineered control routines provides proven solutions for most zone control applications. Custom programs can be easily written in EIKON®-LogicBuilder, ALC’s legendary graphic programming language. • Compact and rugged plastic enclosure for easy mounting. 1150 Roberts Boulevard Kennesaw, Georgia 30144 770/429-3000 Fax 770/429-3001 www.automatedlogic.com CSZN551rev9 Automated Logic Corporation . 1150 Roberts Boulevard . Kennesaw, Georgia 30144 . 770/429-3000 . Fax 770/429-3001 . www.automatedlogic.com © 2011, Automated Logic Corporation. Automated Logic, the Automated Logic logo and WebCTRL are registered trademarks of Automated Logic Corporation. BACnet is a registered trademark of ASHRAE. All other trademarks are the property of their respective owners. Specifications are subject to change without prior notice. ZN551 Specifications BIBB Support: Supports BACnet Interoperability Building Blocks (BIBBs) from the following groups: Data Sharing, and Device and Network Management. Communication: The following ports are available on the ZN551 module: EIA-485 port for ARCNET 156 Kbps or MS/TP (9600 bps – 76.8 Kbps). Local access port for system start-up and troubleshooting. Rnet port for RS room sensors – the Rnet port supports up to four RS sensors and one RS Pro sensor for averaging or high/low select control. NOTE: Local operator interface (BACview ®) is not supported. LogiStat port for LogiStat room sensors. Two Analog Inputs are used by the LogiStat port. NOTE: The LogiStat Pro is not supported on the ZN line (use RS Pro on the Rnet port instead). Digital Outputs: Five digital outputs, relay contact rated at 1A max @ 24V-ac, configured normally open. Universal Inputs: Five inputs with 10 bit A/D resolution. Two inputs are configurable for dry contact, type 2 thermistors, or 0 - 5 V-dc. Inputs 4 and 5 are taken when a LogiStat sensor is connected – these inputs are available if RS sensors are used. Analog Outputs: One analog output, 0-10V-dc with 8-bit resolution. Microprocessor: High speed 16-bit microprocessor with ARCNET communication co-processor. Memory: 512 KByte non-volatile battery-backed RAM, 1 MByte Flash memory, 16-bit memory bus. (Shelf life of the battery is 10 years with 10,000 hours of continuous operation.) Status Indicators: LED status indicators for EIA-485 communication, running, error, power and all digital outputs. Module Addressing: Rotary dip switches for intuitive network addressing of modules. Protection: Built in surge and transient protection circuitry for power and communications. Listed by: UL916 (Canadian Std C22.2 No. 205-M1983), CE, FCC Part 15 – Subpart B – Class A Environmental Operating Range: 0ºF to 130ºF (-17.8ºC to 54.4ºC); 10 -90% relative humidity, non-condensing. NOTE: Control modules should be installed within the building. Power Requirements: 24V-ac ± 10%, 26V-dc (25 V min, 30 V max), 50-60Hz, 15VA Physical: Rugged GE C2950 Cycoloy plastic. Weight: 0.6 lb. (0.27 kg) Dimensions: Overall Width: 5-1/16” (129mm) Height: 5-11/16” (144mm) Depth: 1-1/2” (38mm) min. panel depth Mounting* Two mounting holes center line as at left with 5-9/16” (141mm) spacing (height). *For indoor use only. ZN551 Mounting hole spacing 5-9/16”. LGR Router or ME-LGR Router/Controller To Third Party Equipment BACnet®/IP, 100Base-T Ethernet Ethernet, ARCNET, EIA-485, EIA-232 XML/SOAP HTML/HTTP BACnet MS/TP, ARCNET WML/WAP WML/WAP HTML/HTTP Internet Server Web Browser CellPhone Web Browser PDA ME lineController SE lineController Room Sensor Room Sensor ZN lineController Room Sensor Room Controller ME812u-E Controller Enterprise System CSZN551rev9 1150 Roberts Boulevard, Kennesaw, Georgia 30144 770-429-3000 Fax 770-429-3001 | www.automatedlogic.com © Automated Logic 2016 ZS2 Sensors Intelligent Room Sensors The WebCTRL® building automation system gives you the ability to understand your building operations and analyze the results. The WebCTRL system integrates environmental, energy, security and safety systems into one powerful management tool that allows you to lower energy consumption, increase occupant comfort, and achieve sustainable building operations. Our web-based platform allows building managers to control and access information about their HVAC, lighting, central plant and critical processes on premises or remotely at any time of day. We make data big.™ Next level building automation engineered to help you make smart decisions. Features Temp, CO2 and Humidity Options Addressable / supports daisy-chaining Hidden communication port Occupancy status indicator Push-button occupancy override Setpoint adjust Large, easy- to-read LCD Alarm indicator Motion Sensing Fan speed control Cooling / Heating / Fan Only - Mode Control °F to °C conversion button The Automated Logic® ZS2 room sensors are an integral component of the WebCTRL® building automation system. These sensors provide the function and flexibility you need to manage the conditions important to the comfort, productivity, and sustainability of your facility, and are designed to work with ZN, SE, and ME line controllers. The ZS2 sensors measure room temperature, relative humidity, carbon dioxide, motion and VOCs (volatile organic compounds), and are available in a variety of zone-sensing combinations to address your specific control requirements. %rh Temp IAQ Motion ZS2 Pro-MZS2 Standard ZS2 Pro-FZS2 ProZS2 Plus •••••• •••••••• ••••••••••• •••••••• ••• ••• We make data big.™ Next level building automation engineered to help you make smart decisions. ZS2 Sensors Specifications 11272017 1150 Roberts Boulevard, Kennesaw, Georgia 30144 770-429-3000 Fax 770-429-3001 | www.automatedlogic.com Sensing Element Range Accuracy Temperature with any Option (excluding Humidity) -4° to 122° F (-20° C to 50° C) ±0.35° F (0.2° C) Temperature with Humidity and any Option 50° F to 104° F (10° C to 40° C) ±0.5° F (0.3° C) Humidity 10% to 90% ±1.8% typical CO2 400 to 1250 PPM ±30PPM or +/-3% (greater of two) 1250 to 2000 PPM ±5% of reading plus 30 PPM VOC 0 to 2,000 PPM ±100 PPM Power Requirements Sensor Type Power Required Temperature Only All Models 12 Vdc @ 8 mA Temperature with Humidity Temp with VOC, or Temp/VOC/Humidity All Models 12 Vdc @ 60 mA Temp with CO2 , or Temp/ CO2 /Humidity All Models 12 Vdc @ 15 mA (idle) to 190 mA (CO2 measurement cycle) Power Supply A controller supplies the Rnet sensor network with 12 Vdc @ 210 mA. Additional power may be required. See sensor power requirements above. Communication 115 kbps Rnet connection between sensor(s) and controller 15 sensors max per Rnet network; 5 sensors max per control program Local Access Port For connecting a laptop computer to the local equipment or WebCTRL® network for maintenance and commissioning Environmental Operating Range 32° to 122° F (0° - 50° C), 10% to 90% relative humidity, non-condensing Mounting Dimensions Standard 4”x 2” electrical box using provided 6/32” x 1/2” mounting screws Overall Dimensions Temperature Sensor or Width: 3” (7.62 cm) Temperature with Humidity Sensor Height: 4-13/16” (12.22 cm) Depth: 13/16” (2.01 cm) Sensor with C02 or VOC Width: 2-7/8” (7.3 cm) Height: 4-13/16” (12.22 cm) Depth: 1-1/4” (3.18cm) Options & Part Numbers ZS2 Standard ZS2 Plus ZS2 Pro ZS2 Pro-F ZS2 Pro-M Temperature Only ZS2-ALC ZS2PL-ALC ZS2P-ALC ZS2PF-ALC ZS2P-M-ALC Temp with CO2 ZS2-C-ALC ZS2PL-C-ALC ZS2P-C-ALC ZS2PF-C-ALC ZS2P-CM-ALC Temp with Humidity ZS2-H-ALC ZS2PL-H-ALC ZS2P-H-ALC ZS2PF-H-ALC ZS2P-HM-ALC Temp, Humidity, CO2 ZS2-HC-ALC ZS2PL-HC-ALC ZS2P-HC-ALC ZS2PF-HC-ALC ZS2P-HCM-ALC *Note: To order without an Automated Logic logo, use “BNK” in place of “ALC” above. Sensor Type: PIR Distance: 16.4 feet, (5 m) Detection range: (HxV) 100° x 82° Movement speed: 2.62 to 3.94 ft/s (0.8 to 1.2 m/s) Detection object: 27.56 x 9.84 in. (700 x 250 mm) Motion Sensing B11Temperature Sensors Manufactured by Building Automation Products, Inc., 750 N. Royal Ave., Gays Mills, WI 54631 USA Ph:+1-608-735-4800 • Fax:+1-608-735-4804 • E-mail:sales@bapihvac.com • Web:www.bapihvac.com Automated Logic and the Automated Logic logo are registered trademarks of Automated Logic Corporation l Probe Lengths: 2”, 4”, 8”, 12” and 18” l Series 304 Stainless Steel Probes & Double Encapsulated Sensors l Medical-Grade Foam Padding and Etched Teflon Leadwires l Optional BAPI-Box or BAPI-Box 2 Enclosures Single Point Duct Units feature medical-grade closed cell foam to seal the probe insertion hole and to absorb vibration. Mounting tabs allow for easy installation directly to the wall of the duct. All Duct Units have etched Teflon leadwires and double encapsulated sensors to create a watertight package that can perform under real world conditions. Duct Units have probe lengths from 2” to 18”. Custom probe lengths are also available, call for details. Duct Units come standard with a 2”x4” steel J-Box but are also available with no box, or a watertight BAPI-Box or BAPI-Box 2 enclosure. Duct Units Features & Options No Box J-Box Specifications *Some items may not be CE compliant, call BAPI for additional info. * Rev. 07/13/10 BAPI-Box Duct Units come standard with a 2”x4” steel J-Box Enclosure. Add -BB to the end of the part # for a BAPI-Box enclosure or -BB2 for a BAPI-Box 2 enclosure Add -NB to the end of the part # for No Box. Please also specify a lead length for the plenum-rated cable of -18”, -5’, -10’ or -15’. Example -NB-18” for No Box with 18” lead length Ordering Information/Part Numbers ALC/10K-2-D-2”: Duct Unit with 2” Probe ALC/10K-2-D-4”: Duct Unit with 4” Probe ALC/10K-2-D-8”: Duct Unit with 8” Probe Enclosure Material: BB or BB2 Models: Polycarbonate J-Box Model: Galv. Steel Environmental Operation Range: Temperature: -40 oC to 100 oC Humidity: 0 to 100%, non-condensing Enclosure Material Rating: BB or BB2 Models: UL94, V-0 Encl. Rating: BB or BB2 Models: IP66 10K-2 Thermistor Sensor Specifications Resistance:10 kW @ 25°C, -55°C to 150°C range Standard Accuracy: 0.2°C (±0.36°F) at 0 to 70°C Dissipation Constant: 2.7 mW/°C Stability(drift): Less than ±0.1°C (0.18°F) drift over 10 years. ALC/10K-2-D-12”: Duct Unit with 12” Probe ALC/10K-2-D-18”: Duct Unit with 18” Probe BAPI-Box 2 (BB2) J-Box (Standard) No Box (NB) BAPI-Box 2 (BB2)BAPI-Box (BB) 800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA 11O50905 - 03/12 - Subject to change. © Belimo Aircontrols (USA), Inc.B2 Series, 2-Way, Characterized Control Valve Stainless Steel Ball and Stem Technical Data Service chilled or hot water, 60% glycol Flow characteristic A-port equal percentage Controllable Flow Range75° Sizes ½”, ¾”, 1”, 1¼”, 1½”, 2”, 2½”, 3” Type of end fi tting NPT female ends Materials: Body Ball Stem Seats Characterizing disc Packing forged brass, nickel plated stainless steel stainless steel PTFE Tefzel® 2 EPDM O-rings, lubricated Body pressure rating 600 psi 400 psi ½” - 1¼” (B230) 1¼” (B231) - 3” Media temp. range 0°F to 250°F [-18°C to 120°C] Close off pressure 200 psi 100 psi ½” - 2” (B250) 2” (B251) - 3” Maximum differential pressure (ΔP) 50 psi for typical applications Leakage 0% for A to AB External leakage according to EN 12266-1:2003 Cv rating A-port: see product chart for values Te fzel® is a registered trademark of DuPont Dimensions 2WayValve-B207-B220Valve Nominal Size Dimensions (Inches [mm]) Valve Body Inches DN [mm]A B B207-B211 ½”15 2.41” [61.1]1.39” [35.2] B212-B216 ½”15 2.38” [60.4]1.78” [45.2] B217-B221 ¾”20 2.73” [69.3]1.87” [47.4] B222-B225 1”25 3.09” [78.4]1.87” [47.4] B229-B230 1¼” 32 3.72” [94.6] 1.87” [47.4] B231-B232 1¼”32 3.72” [94.6]2.04” [51.9] B238-B240 1½”40 3.88” [98.5]2.04” [51.9] B248-B250 2”50 4.21” [107.0]2.27” [57.7] B251-B254 2” 50 4.93” [125.2]2.73” [69.5] B261-B265 2½”65 5.55” [140.9]2.73” [69.5] B277-B280 3” 80 5.82” [147.9]2.73” [69.5] A pplication This valve is typically used in air handling units on heating or cooling coils, and fan coil unit heating or cooling coils. Some other common applications include Unit Ventilators, VAV box re-heat coils and bypass loops. This valve is suitable for use in a hydronic system with variable fl ow. Valve Nominal Size Type Suitable Actuators Cv Inches DN [mm] 2-Way NPT Non-Spring Spring 0.3 ½15 B207 TR SeriesLR SeriesNR...N4 SeriesTF SeriesLF Series0.46 ½15 B208 0.8 ½15 B209 1.2 ½15 B210 1.9 ½15 B211 3 ½15 B212 4.7 ½15 B213 7.4 ½15 B214 10 ½15 B215 14 ½15 B216 4.7 ¾20 B217 7.4 ¾20 B218 10 ¾20 B219 14 ¾20 B220 24 ¾20 B221 7.4 1 25 B222 10 1 25 B223 19 1 25 B224 30 1 25 B225* 10 1¼32 B229 19 1¼32 B230* 25 1¼32 B231 AR SeriesAR...N4 SeriesAF Series37 1¼32 B232* 19 1½40 B238 29 1½40 B239 37 1½40 B240* 29 2 50 B248 46 2 50 B249 57 2 50 B250* 65 2 50 B251 85 2 50 B252 120 2 50 B253 240 2 50 B254* 60 2½65 B261 75 2½65 B262 110 2½65 B263 150 2½65 B264 210 2½65 B265* 70 3 80 B277 130 3 80 B278 170 3 80 B280* *Models without characterizing disc Flow Patterns 800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA 76 O50905 - 03/12 - Subject to change. © Belimo Aircontrols (USA), Inc.TFRB(X)24-SR Actuators, Proportional Models TFRB(X)24-SR TFRB(X)24-SR-S w/built-in Aux. Switch Technical Data Control proportional Power supply 24 VAC ± 20%, 50/60 Hz 24 VDC ± 10% Power consumption running 2.5 W holding 1.0 W Transformer sizing 4 VA (class 2 power source) Electrical connection (-S models have 2 cables) TFRB(X)24-SR... ½” conduit connector 18 GA plenum rated cable 3 ft [1m] 10 ft [3m] 16 ft [5m] Electrical protection actuators are double insulated Overload protection electronic throughout 0° to 95° rotation Operating range Y 2 to 10 VDC, 4 to 20 mA Input impedance 100k Ω (0.1mA), 500 Ω Angle of rotation 95° Direction of rotation spring reversible with CW/CCW mounting motor reversible with built-in Position indication visual indicator, 0° to 95° Running time motor 95 sec constant, independent of load spring <25 sec @-4°F to 122°F [-20°C to 50°C] <60 sec @-22°F [-30°C] Humidity 5 to 95% RH non-condensing Ambient temperature -22°F to 122°F [-30°C to 50°C] Storage temperature -40°F to 176°F [-40°C to 80°C] Housing NEMA type 2/IP42 Housing material UL94 - 5VA Agency listings†cULus according to UL 60730-1A/-2-14, CAN/ CSA E60730-1:02, CE according to 2004/108/ EC and 2006/95/EC for line voltage and/or –S versions Noise level (max)running <35 db (A) spring return <62 dB (A) Quality standard ISO 9001 TFRB(X)24-SR-S Auxiliary switch 1 x SPDT, 3A (0.5A) @ 250 VAC, UL Listed, adjustable 0° to 95° † Rated impulse voltage 800V (4kV for 120V model), Control pollution degree 3, Type of action 1.AA (1.AA.B for -S models) Dimensions with 2-Way Valve 6.28" [159.55] 2.93" [74.5] 2.4 [6 B 3.05" [76.2]94D09Valve Nominal Size Dimensions (Inches [mm]) Valve Body Inches DN [mm]A B B207(B)-B211(B)½”152.41” [61.1]1.39” [35.2] B212(B)-B215(B)½”15 2.38” [60.4]1.78” [45.2] B217(B)-B220(B)¾”20 2.73” [69.3]1.87” [47.4] Dimensions with 3-Way Valve 6.28" [159.55] 3.05" [76.2] 2.93" [74.5] 2.4 [61 B A C 95D09Valve Nominal Size Dimensions (Inches [mm]) Valve Body Inches DN [mm]A B C B307(B)-B311(B)½”15 2.41” [61.1]1.39” [35.2]1.20” [30.6] B312(B)-B315(B)½”15 2.38” [60.4]1.78” [45.2]1.29” [32.8] B317(B)-B320(B)¾”20 2.73” [69.3]1.87” [47.4]1.47” [37.3] 800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA 77O50905 - 03/12 - Subject to change. © Belimo Aircontrols (USA), Inc.Wiring Diagrams 2 CAUTION Equipment damage! Actuators may be connected in parallel. Power consumption and input impedance must be observed. 4 Up to 4 actuators may be connected in parallel. With 4 actuators wired to one 500 Ω resistor, a +2% shift of control signal may be required. Power consumption must be observed. 3 Actuators may also be powered by 24 VDC. 5 Only connect common to neg. (—) leg of control circuits. 6 Actuators with plenum rated cable do not have numbers on wires; use color codes instead. 7 For end position indication, interlock control, fan startup, etc., TF24-SR-S US incorporates one built-in auxiliary switch: 1 x SPDT, 3A (0.5A ) @250 VAC, UL listed, adjustable 0° to 95°. Meets cULus or UL and CSA requirements without the need of an electrical ground connection. WARNING Live Electrical Components! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualifi ed licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. TFRB(X)24-SR Actuators, Proportional 1 6 2 3 24 VAC Transformer Blk (1) Common Red (2) + Hot Wht (3) Y Input, 2 to 10V TF24-SR US Line Volts 2 to 10 VDC Control Signal (–) (+)W2452 to 10 VDC control 4 To other actuators 6 3 5 24 VAC Transformer Blk (1) Common Red (2) + Hot Wht (3) Y Input, 2 to 10V 4 to 20 mA Control Signal (–) (+) Ω 500Ω 2 TF24-SR US Line Volts 1 W2464 to 20 mA control TF24-SR-S US 7S1 S2 S3 NC NO 0° to 95° Auxiliary switch 800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA 18 N40013 - 06/11 - Subject to change. © Belimo Aircontrols (USA), Inc.TR24-SR Actuators, Proportional Models TR24-SR-T US TR24-SR US TR24-SR-T US with 3 ft plenum rated cable TR24-SR/300 US TR24-SR-T US with 10 ft plenum rated cable TR24-SR/500 US TR24-SR-T US with 16 ft plenum rated cable Technical Data Control proportional Nominal voltage 24 VAC 50/60 Hz, 24 VDC Nominal voltage range 19.2…28.8 VAC, 21.6…28.8 VDC Power consumption 0.5 W Transformer sizing 1VA (class 2 power source) Electrical connection screw terminals accessible after removal of small cover (3 ft, 10 ft, 16 ft cables optional) Input impedance 100 kΩ Angle of rotation 90° Direction of rotation reversible with switch under cover Position indication integrated into handle Manual override push down handle Running time 90 seconds Humidity 5 to 95% non-condensing Ambient temperature -22°F to 122°F (-30°C to 50°C) Storage temperature -40°F to 176°F (-40°C to 80°C) Housing NEMA 1/IP40 Housing rating UL94-5V(B) Agency listing†cULus according to UL 60730-1A/-2-14, CAN/ CSA E60730-1:02, CE according to 2004/108/ EC and 2006/95/EC for line voltage and/or –S versions Noise level max. 35 db (A) Quality standard ISO 9001 † Rated impulse voltage 500V, Control pollution degree 2, Type of action 1 NOTE:Response sensitivity is 75mV Dimensions with 2-Way Valve A 2.50 [63.5] 3.25 [82.6] B 2.82 [71.6]D069Valve Nominal Size Dimensions (Inches [mm]) Valve Body Inches DN [mm]A B B207(B)-B211(B)½”152.41” [61.1]1.39” [35.2] B212(B)-B215(B)½”15 2.38” [60.4]1.78” [45.2] B217(B)-B220(B)¾” 20 2.73” [69.3]1.87” [47.4] Dimensions with 3-Way Valve A 2.50 [63.5] 3.25 [82.6] B 2.82 [71.6] C D072D07Valve Nominal Size Dimensions (Inches [mm]) Valve Body Inches DN [mm]A B C B307(B)-B311(B)½”15 2.41” [61.1]1.39” [35.2]1.20” [30.6] B312(B)-B315(B)½”15 2.38” [60.4]1.78” [45.2]1.29” [32.8] B317(B)-B320(B)¾” 20 2.73” [69.3]1.87” [47.4] 1.47” [37.3] 800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA 19N40013 - 06/11 - Subject to change. © Belimo Aircontrols (USA), Inc.Wiring Diagrams 2 Actuators with color coded wires are optional. Wire numbers are provided for reference. CAUTION Equipment damage! Actuators may be connected in parallel. Power consumption and input impedance must be observed. 3 Actuators may also be powered by 24 VDC. WARNING Live Electrical Components! During installation, testing, servicing and troubleshooting of this product, it may be necessary to work with live electrical components. Have a qualifi ed licensed electrician or other individual who has been properly trained in handling live electrical components perform these tasks. Failure to follow all electrical safety precautions when exposed to live electrical components could result in death or serious injury. TR24-SR Actuators, Proportional W1902 to 10 VDC Control of TR24-SR(-T) US W1914 to 20 mA Control of TR24-SR(-T) US Direct/Reverse acting switch is under wiring cover. R = CW with decrease in signal L = CCW with decrease in signal No feedback Functional Devices, Inc. • p: 800.888.5538 • f: 765.883.7505 • www.functionaldevices.com • sales@functionaldevices.com 3 Secondaries: 24 Vac, with LED Indicators 24 Vac ON/OFF: On / Off Switch & Breaker Input: 480/277/240/120 Vac Finger-Safe Terminals, 8-18 AWG Output: 3 Isolated, Floating 100 VA Class 2 24 Vac Terminals, 12-26 AWG Standby Wattage: 16.61 W @ 120 Vac 17.70 W @ 240 Vac 16.26 W @ 277 Vac 19.20 W @ 480 Vac Full Load Primary Current: 2.66 A @ 120 Vac 1.36 A @ 240 Vac 1.18 A @ 277 Vac 0.68 A @ 480 Vac Secondary Output Voltage vs. Load: 24.5 V @ 1 Amp 23.5 V @ 2 Amp 22.8 V @ 3 Amp 22.3 V @ 4 Amp • With 120 Vac primary input voltage • When all 3 outputs operated simultaneously, at room temperature Transformer: Over Current Protection: Primary: Frequency: Dimensions: Approvals: Sub-Panel: Housing: Weight: One (1) 300 VA Circuit Breaker 480/277/240/120 Vac 50/60 Hz 12.125˝ x 12.125˝ x 6.000˝ (PSH300A) 11.330˝ x 11.400˝ x 4.500˝ (PSMN300A) Class 2 (UL Approved UL5085-3), UL916, C-UL, CE, RoHS Plenum Rated Polymetal Sub-Panel (PSMN300A) NEMA1 Metal Enclosure (PSH300A) 20.00 lbs. (PSH300A) 11.00 lbs. (PSMN300A) PSH300A Enclosed 300VA Power Supply with Three 100VA Class 2 Outputs, 480/277/240/120 Vac to 24 Vac PSMN300A Open Style 300VA Power Supply with Three 100VA Class 2 Outputs, 480/277/240/120 Vac to 24 Vac Notes: • Open style is mounted to sub-panel SP3303 for shipping and may be remounted to suit application. 11.400”11.330” 1 2 3 ON OFF ON OFF ON OFF Indicator Breaker Switch 24V COM 24V COM 24V COM User Connections480 277 240 120 COM AC Power Supply PSH300A Shown With Cover PSH300A Shown Without Cover PSMN300A • Great for VAV Applications Specifications Made in USA Meets “Buy American” of ARRA 2009 Class 2 Ambient Temperature Derating: 4A up to 40˚ C ; 3A up to 50˚ C ; 2A up to 55˚ C (When All 3 Outputs Operated Simultaneously) Functional Devices, Inc. • p: 800.888.5538 • f: 765.883.7505 • www.functionaldevices.com • sales@functionaldevices.com PSH500A Shown With Cover PSH500A Shown Without Cover 5 Secondaries: 24 Vac, with LED Indicators 24 Vac ON/OFF: On / Off Switch & Breaker Input: 480/277/240/120 Vac Finger-Safe Terminals, 8-18 AWG Output: 5 Isolated, Floating 100 VA Class 2 24 Vac Terminals, 12-26 AWG Ambient Temperature Derating: 4A up to 40˚ C ; 3A up to 50˚ C ; 2A up to 55˚ C (When All 5 Outputs Operated Simultaneously) Standby Wattage: 48.515 W @ 120 Vac 48.699 W @ 240 Vac 49.564 W @ 277 Vac 48.255 W @ 480 Vac Full Load Primary Current: 4.66 A @ 120 Vac 2.41 A @ 240 Vac 2.06 A @ 277 Vac 1.17 A @ 480 Vac Secondary Output Voltage vs. Load: 24.0 V @ 1 Amp 23.0 V @ 2 Amp 21.8 V @ 3 Amp 21.1 V @ 4 Amp • With 240 Vac primary input voltage • When all 5 outputs operated simultaneously, at room temperature Transformer: Over Current Protection: Primary: Frequency: Dimensions: Approvals: Sub-Panel: Housing: Weight: One (1) 500 VA Circuit Breaker 480/277/240/120 Vac 50/60 Hz 12.125˝ x 12.125˝ x 6.000˝ (PSH500A) 11.330˝ x 11.400˝ x 5.000˝ (PSMN500A) Class 2 (UL Approved UL5085-3), UL916, C-UL, CE, RoHS Plenum Rated Polymetal Sub-Panel (PSMN500A) NEMA1 Metal Enclosure (PSH500A) 30.16 lbs. (PSH500A) 20.60 lbs. (PSMN500A) PSH500A Enclosed 500VA Power Supply with Five 100VA Class 2 Outputs, 480/277/240/120 Vac to 24 Vac PSMN500A Open Style 500VA Power Supply with Five 100VA Class 2 Outputs, 480/277/240/120 Vac to 24 Vac Notes: • Open style is mounted to sub-panel SP3303 for shipping and may be remounted to suit application. • Great for VAV Applications PSMN500A 24V COM 24V COM 24V COM 24V COM 24V COM 1 2 3 4 5 Indicator Breaker User ConnectionsSwitch ON OFF ON OFF ON OFF ON OFF ON OFF 480 277 240 120 COM 11.400”11.330”AC Power Supply Specifications Made in USA Meets “Buy American” of ARRA 2009 Class 2 102915RELAYS(800) 888-5538 sales@functionaldevices.com www.functionaldevices.com # Relays & Contact Type: Expected Relay Life: Operating Temperature: Humidity Range: Operate Time: Relay Status: Dimensions: Wires: Approvals: Housing Rating: Gold Flash: Override Switch: One (1) SPDT Continuous Duty Coil 10 million cycles minimum mechanical -30 to 140° F 5 to 95% (noncondensing) 18ms LED On = Activated 2.30˝ x 3.20˝ x 1.80˝ with .50˝ NPT Nipple 16˝, 600V Rated UL Listed, UL916, UL864, C-UL California State Fire Marshal, CE, RoHS UL Accepted for Use in Plenum, NEMA 1 No Yes (2) Contact Ratings: 20 Amp Resistive @ 277 Vac 20 Amp Ballast @ 277 Vac (N/O) 10 Amp Ballast @ 277 Vac (N/C) Not rated for Electronic Ballast 10 Amp Tungsten @ 120 Vac (N/O) 770 VA Pilot Duty @ 120 Vac 1,110 VA Pilot Duty @ 277 Vac 2 HP @ 277 Vac 1 HP @ 120 Vac Coil Current: 50 mA @ 18 Vac 83 mA @ 24 Vac 47 mA @ 120 Vac (RIB2401SBC) 69 mA @ 208-277 Vac (RIB2402SBC) Coil Voltage Input: 24 Vac/dc ; 120 Vac ; 50-60 Hz (RIB2401SBC) 24 Vac/dc ; 208-277 Vac ; 50-60 Hz (RIB2402SBC) Drop Out = 2.1 Vac / 3.8 Vdc Pull In = 18 Vac / 22 Vdc RIB2401SBC Enclosed Relay 20 Amp SPDT + Override with 24 Vac/dc/120 Vac Coil RIB2402SBC Enclosed Relay 20 Amp SPDT + Override with 24 Vac/dc/208-277 Vac Coil 33 mA @ 22 Vdc 35 mA @ 24 Vdc 47 mA @ 30 Vdc Wht/Brn 208-277 Vac Wht/Blu 24 Vac/dc Wht/Yel Comm AUTO N/C CLOSED OPEN N/O CLOSED Yel Comm Org N/O Blu N/C MANUAL Wht/Blk 120 Vac Wht/Blu 24 Vac/dc Wht/Yel Comm AUTO N/C CLOSED OPEN N/O CLOSED Yel Comm Org N/O Blu N/C MANUAL Made in USA Meets “Buy American” of ARRA 2009 20 AMP POWER CONTROL RELAYS SPECIFICATIONS Functional Devices, Inc. • p: 800.888.5538 • f: 765.883.7505 • www.functionaldevices.com • sales@functionaldevices.com 080814 Operating Temperature: Humidity Range: Accuracy: Loading: Max Sense Voltage: Approvals: Mounting/Installation: Sensor Type: -30 to 140° F 5 to 95% (noncondensing) 96.8% Full Scale RIBXKTV5-10, 1% Error @ 180 kΩ RIBXKTV5-20, 1% Error @ 90 kΩ RIBXKTV5-50, 1% Error @ 40 kΩ RIBXKTV5-100, 1% Error @ 15 kΩ 600 Vac UL Listed, UL916, UL864, California State Fire Marshal, C-UL, CE, RoHS Removable mounting tab provided. The wire clamp locks against the wire being monitored, securing the unit in place. Solid core with voltage output RIBXKTV Series Enclosed Self-Powered Solid Core Current to DC Transducers Made in USA Meets “Buy American” of ARRA 2009 Specifications AC Transducers, 0-5 Vdc Out, Solid Core RIBXKTV Series Selection Guide Model#Sensing Range Sensor Output RIBXKTV5-10 0-10 Amp 0-5 Vdc (Terminal Strip, Accepts #14-22 AWG Wire) RIBXKTV5-20 0-20 Amp 0-5 Vdc (Terminal Strip, Accepts #14-22 AWG Wire) RIBXKTV5-50 0-50 Amp 0-5 Vdc (Terminal Strip, Accepts #14-22 AWG Wire) RIBXKTV5-100 0-100 Amp 0-5 Vdc (Terminal Strip, Accepts #14-22 AWG Wire) 1.460” 1.863” 2.050” Removable Mounting TabWire Clamp .500” Diameter 1.008” 2.050” Output: Terminal Strip Accepts 14-22 AWG wire + – Applications ■ HVAC ■ Refrigeration ■ Pumps ■ Small Industrial Motors ■ Fans ■ Lighting CSS Series Features ● Solid Core Design ● Adjustable Switch Setpoints ● Switch Led Indication ● Relay Led Indication ● Over/Under Current Sensing ● Snap on Power Relay CSC Series Features ● Clamped/Split Core Design ● Adjustable Switch Setpoints ● Switch LED Indication ● Relay LED Indication ● Over/Under Current Sensing ● Snap on Power Relay Benefits ■ Low Cost Solution ■ Self Powered ■ Simple Installation ■ Accurate Fixed Setpoint Models, No Guessing at Switchover Current 800-257-3872 Visit Setra Online: http://www.setra.com ISO-9001 Certified MODEL CSSGFN025NN CSSGA2100NN CSSGA2100R1 w/snap-on relay Amperage Range 0.25 to 200 A 1.00 to 135 A 1.00 to 135 A Continuous Operating Current 200 A, 600 V AC 125 A, 600 V AC 135 A, 600 V AC Switch Setpoint Fixed Adjustable Adjustable Output Relay No No SPST,NO. 10 A @ 260 V AC, 5 A @ 30 V DC Actuation Coil No No 24 V AC/DC Switch LED Indication No Yes Yes Relay LED Indication No No Yes Trip Setpoint Value 0.25 A 1.00 to 135 A 1.00 to 135 A Current Switching Mode Under Current Sensing Over/Under Current Sensing Over/Under current Sensing Dimensions 2.54 x 1.85 x 0.98 in. (65 x 47 x 25 mm) 2.54 x 1.85 x 0.98 in. (65 x 47 x 25 mm) 2.54 x 2.56 x 1.56 in. (65 x 65 x 40 mm) Aperture (Sensing Hole Size) 0.71 in. Dia. (18 mm Dia.) Sensor Supply Voltage Induced from power conductor cable Status Output Switch normally open Switch Load Capacity 1 A @ 30 V AC/DC max. Isolation Voltage 600 V AC ms Temperature Range 5 to 140°F (-15 to 60°C) Frequency Range 50/60 Hz Humidity Range 0 to 95% non-condensing Agency Approvals CE Compliant, RoHS Compliant, c-UL Listed: 508, IND. Cont. EQ: E317719 CSS Series Solid Core Current Switches The CSS models are ideal for new instal- lations and provide the greatest savings opportunity. Ideal for direct drive units, small exhaust fans, and other fi xed loads, these solid state switches have accurate, very low fi xed or user adjustable setpoints. which are activated when the desired amperage is reached. The adjustable CSSGA2100NN and CSSGA2100R1 units have LED’s which indi- cate switch status. (User can also adjust the setpoint for over or under loads.) Excitation is magnetically induced from cur- rent carrying conductor (wire or cable), mak- ing these units completely self-powered. The CSS Series, solid core, current switch’s convenient wide orifi ce allows easy pass through of the conductor, and is bundled with a mounting bracket and hardware, making installation easy. Model CSSGA2100R1 is equipped with a snap-on power relay for remote motor startup. CSS Series (Current Switch Solid) Specifi cations Specifi cations are subject to change without notice. MODEL CSCGFN015NN CSCGFN150NN CSCGA2125NN CSCGFN150R1 w/snap-on relay CSCGA2125R1 w/snap-on relay Amperage Range 0.15 to 200 A/ 1.5 to 200 A 1.25 to 135 A 1.5 to 200 A 1.25 to 135 A Continuous Operating Current 200 A, 600 V AC/ 200 A, 600 V AC 135 A, 600 V AC 200 A, 600 V AC 135 A, 600 V AC Switch Setpoint Fixed Adjustable Fixed Adjustable Output Relay No No SPST.NO 10 A @ 260 V AC, 5 A @ 30 VDC SPST. NO 10 A @ 260 V AC, 5 A @ 30 V DC Actuation Coil No No 24 V AC/DC 24 V AC/DC Switch LED Indication No Yes No Yes Relay LED Indication No No Yes Yes Trip Setpoint Value 0.15 A/1.5 A 1.25 to 135 A 1.5 A 1.25 to 135 A Current Switching Mode Under current sensing Over/Under current sensing Under current sensing Over/Under current sensing Dimensions 2.7 x 2.56 x 1.08 in. (69 x 65 x 27 mm) 2.7 x 2.56 x 1.08 in. (69 x 65 x 27 mm) 2.7 x 2.56 x 1.73 in. (69 x 65 x 44 mm) 2.7 x 2.56 x 1.73 in. (69 x 65 x 44 mm) Aperture Size 0.72 x 0.78 in. (18 x 20 mm) Sensor Supply Voltage Induced from power conductor cable Status Output Switch normally open Switch Load Capacity 1 A @ 30 V AC/DC max. Isolation Voltage 600 V AC rms. Temperature Range 5 to 140 °F (-15 to 60 °C) Frequency Range 50/60 Hz Humidity Range 0 to 95% non-condensing Agency Approvals CE Compliant. RoHS Compliant, c-UL Listed: 508., IND. Cont. EQ: E317719 CSC Series Split Core Current Switches A signifi cant increase or decrease in op- erating current may result in motor, belt loss, slippage, or mechanical failure, which could jeopardize the user’s process. The split core design of the Model CSC is an ideal solution, as it can easily be clamped onto existing power cables or wires. These units are offered with industry stan- dard 135 Amp or 200 Amp output and very low fi xed or adjustable setpoints,. which are activated when the desired am- perage is reached. Model CSCGA2125NN and CSCGA2125R1 include LEDs for indi- cation of switch status. (Setpoint can be adjusted for over or under loads.) Model CSCG FN150R1 and CSCGA2125R1 are equipped with a snap-on power relay for remote motor startup. CSC Series (Current Switch Clamped) Specifi cations Specifi cations are subject to change without notice. Applications ■ HVAC ■ Refrigeration ■ Pumps ■ Small Industrial Motors ■ Fans ■ Lighting CSS Series Features ● Solid Core Design ● Adjustable Switch Setpoints ● Switch Led Indication ● Relay Led Indication ● Over/Under Current Sensing ● Snap on Power Relay CSC Series Features ● Clamped/Split Core Design ● Adjustable Switch Setpoints ● Switch LED Indication ● Relay LED Indication ● Over/Under Current Sensing ● Snap on Power Relay Benefi ts ■ Low Cost Solution ■ Self Powered ■ Simple Installation ■ Accurate Fixed Setpoint Models, No Guessing at Switchover Current 800-257-3872 Visit Setra Online: http://www.setra.com ISO-9001 Certifi ed Outline Drawings 159 Swanson Road, Boxborough, Massachusetts 01719/Tel: 800-257-3872; Fax: 978-264-0292; Email: sales@setra.com; Web: www.setra.com While we provide application assistance on all Setra products, both personally and through our literature, it is up to the customer to determine the suitability of the product in the application. ORDERING INFORMATION SSP-CSS-CSC Rev B 03/02/2010 Models CSSGFN025NN CSSGA2100NN Models CSSGA2100R1 Models CSCGFN015NN CSCGFN150NN CSCGA2125NN Models CSCGFN150R1 CSCGA2125R1 CAUTION, RISK of ELECTRIC SHOCK Disconnect power supply before making electrical connections. contact with components carrying hazardous voltage can cause electrical shock and may result in severe personal injury or death. ! CSS Series (Current Switch Solid) 1.85 47 2.54 65 0.98 25 1.08 27 2.56 65 2.54 65 1.56 40 1.08 27 CSC Series (Current Switch Clamped) 2.70 69 2.56 65 1.06 27 2.70 69 2.56 65 1.73 44 in. mm Model CSS Series (Current Switch Solid) Model No. Description CSSGFN025NN Model CSS, Fixed Setpoint, No LED, 0.25 A Setpoint, No Snap-on Power Relay CSSGA2100NN Model CSS, Adjustable Setpoint, with LED, 1.00 A Setpoint, No Snap-on Power Relay CSSGA2100R1 Model CSS, Adjustable Setpoint, with LED, 1.00 A Setpoint, with Snap-on Power Relay Model CSC Series (Current Switch Clamped) Model No. Description CSCGFN015NN Model CSC, Fixed Setpoint, No LED, 0.15 A Setpoint, No Snap-on Power Relay CSCGFN150NN Model CSC, Fixed Setpoint, No LED, 1.50 A Setpoint, No Snap-on Power Relay CSCGA2125NN Model CSC, Adjustable Setpoint, with LED, 1.25 A Setpoint, No Snap on Power Relay CSCGFN150R1 Model CSC, Fixed Setpoint, No LED, 1.50 A Setpoint, with Snap-on Power Relay CSCGA2125R1 Model CSC, Adjustable Setpoint, with LED, 1.25 A Setpoint, with Snap-on Power Relay † Contact factory to order power relay separately. Phone: 800-257-3872 • Fax: 978-264-0292 • setra.com © Setra Systems, Inc. All rights reserved. The Setra Systems name and logo are registered trademarks of Setra Systems, Inc. Model MRG Multi-Range General Pressure Transducer The Setra Model MRG is Setra’s newest differential pressure transducer. The Setra MRG is the ideal product for any contrac- tor, combining the flexibility of a multi-range with the perfor- mance of a single range transducer. The MRG has 8 selectable ranges and 3 selectable outputs, easily adjustable on the job with a flip of a switch or jumper. The MRG uses an IP67 rated housing and has a conduit fitting for easy wiring, making the MRG an ideal solution for any general HVAC application. 8 Field Selectable Ranges The Setra MRG provides 8 field selectable ranges (0.5, 1.0, 2.5 and 5.0”W.C.). These ranges can be selected on site by flipping the jumper to the desired range. Setra chose these ranges from analyzing 30 years worth of customer data that proved up to 90% of all differential pressure transducers ordered from Setra that require 1.0% accuracy are between 0.5 and 5.0”W.C. Universal Design The Setra MRG utilizes a universal design that gives the user total flexibility to make changes on the job site. The user has the option to choose the field configurable range, mounting (DINrail, wall mount and duct mount), output (mA or Volt) and engineering unit (W.C. or Pascals). This flexibility means that the contractor can use the MRG for all of their needs. IP67 Rated Housing The MRG housing is a robust IP64 rated design and is sealed with a gasket to make it wash-down capable for difficult appli- cations. The MRG also has a conduit fitting that make installa- tion and wiring easier. Capacitive Sensing Technology Only Setra can claim ownership to the stainless steel capacitive design used in all of our HVAC/R sensors. Our advanced capac- itive element provides excellent stability and linearity, while standing above the competitors in our ability to measure low pressure (<0.001”W.C.) at high accuracy. Our technology has been used in over 8 million installations and has the highest field acceptance rate in the industry. n Robust for Wash-Down Environments n IP67 Rated Housing n Field Selectable Model MRG Features: • Field Configurable Duct Probe • 4 Digit LCD • Field Selectable Range • Field Selectable Output • Simple 5-Step Setup • Field Accessible Push-Button Zero & Span • External Mounting Tabs & Optional DINrail • Unregulated AC/DC Operation • IP67 Rated Housing Target Uses: • Sub-Contractors- Quick Installation • Flexible for Building Specification Changes • Service/Retrofit Friendly • Service Technicians- Quick & Accurate Reconfiguration Phone: 800-257-3872 • Fax: 978-264-0292 • setra.com © Setra Systems, Inc. All rights reserved. The Setra Systems name and logo are registered trademarks of Setra Systems, Inc. Model MRG Mutli-Range General Pressure Transducer SSMRG WIRING GENERAL SPECIFICATIONS ORDERING INFORMATION Ordering Example: MRGSN = Model MRG, Standard Configuration, with 1/2” Conduit. Performance Data Environmental Data Standard Operating Temperature3 32 to 122°F (0 to 50°C) Accuracy RSS1 (at constant temp)±1.0% FS Electrical Data Compensated Range ºF (ºC)32 to 122°F (0 to 50°C) Excitation Range 13 to 30 VDC/18 to 24 VAC (Voltage Output) 13 to 30 VDC (4 to 20mA output at terminals) Thermal Effects2 %FS/ºF(ºC)0.03 (0.054)Current Consumption 30mA (max) Maximum Line Pressure 10 PSI Mis-Wiring Reverse Excitation Protection Overpressure Up to 10 PSI (range dependent) Field Selectable Output4 0 to 5 V, 0 to 10V (3-wire), 4 to 20mA (2-wire) Long Term Stability (max.)2.0% FS/YR Output Resistance (Voltage Output) 10 Ohms (max) Position Effect Load Resistance (Voltage Output) 10 K-Ohms (min) Zero Offset %FS/G 0.5%Loop Resistance (4-20mA)0 to 800 Ohms (Unit is factory calibrated at 0g effect in the vertical position)Approval CE & RoHS Compliant Physical Description Pressure Media Case Fire-Retardant Polycarbon- ate (UL 94 V-0 Approved), Hinged Lid Typically air or similar non-conducting gases. Mounting Two Screw Holes Vertical Position 1 RSS of Non-Linearity, Hysteresis, and Non-Repeatability. 2 Units calibrated at nominal 70˚F. Maximum thermal error computed from this datum. 3 Operating temperature limits of the electronics only. Pressure media temperatures may be considerably higher. 4 Calibrated into a 50K ohm load, operable into a 10K ohm load or greater. 5 Span (Full Scale) output factory set to within 1%. 6 Calibrated at factory with a 24 VDC loop supply voltage and a 250 ohm load. 7 Span (Full Scale) output factory set to within ±0.16mA. Specifications subject to change without notice. Electrical Connection Block Removable Screw Terminal Pressure Fitting 3/16” O.D. Barbed Brass Zero Push Button Span Push Button Weight (approx.)8 Ounces 3-Wire, 0-5, 0-10 VDC Configuration Model MRG - EXC COM OUT Power Supply 13 - 30V - 24V AC/DC Nominal Excitation - Voltage Monitor + + + + 2-Wire, 4-20 mA Configuration Model MRG + - EXC COM OUT + - 24V (DC Only) Nominal Excitation + - X Typical 250 Ohm Sense Resistor for 1-5V Output Measurement Power Supply 13 - 30V Current Monitor Model Field Selectable Ranges Configuration1 Options MRG Unidirectional Pressure Ranges Bidirectional Pressure Ranges S Standard A 1/2” Conduit 0.5”W.C.100 Pa ±0.5”W.C ±100Pa U Universal P PG9 1.0”W.C.250 Pa ±1.0”W.C.±250 Pa D DIN Rail 2.5”W.C.500 Pa ±2.5”W.C ±500Pa P Duct Probe 5.0”W.C.1,000 Pa ±5.0”W.C.±1,000Pa M R G 1Codes with Cal Certification are from ±5”W.C. ranges. Code U, Universal unit includes duct probe and DIN Rail options. 2 V 2 w z J G0065 G0045 G0005 1 30231 BRICK PATIO MATCH TO G0024 RIGHT 1019E 1018 a G0007 — BRICK PATIO G0040 G0073 16121 G0043 G0042 G0070 1 41 I G0064 1 64101 G65 G67 G69 1 1871 G0063 G59 194 1 G57 1 5951 1 G56 1 5951 G0062 G0020 G68 G0048 G0066 G0061 I 33 I G0002 1 2391 G54B 87 G52B ao G68A 40 G54A 83 G50E 62 G5OF 62 G40 1 1571 G0076 1 56 1 G52A 50 G50A 96 G0049 1 378 I G0047 1 205 1 G0021 141 G0046 904 I G0071 1 65 1 37 1 1 847 1 1 10731 1 492 1 1 los 1 DN G0004 1 58 1 111111111 G41 1 156 G41A I 60 1 G0067 1 483 1 G43 1450 1 LOCATION MAP N CDGROUND FLOOR PLAN GROSS AREA = 38,313 SQ. FT. 1018 �\\ 1014 MATCH TO F - w J c�O9 G07 G0050 111021 1 129 1 G0072 1155] 1 1841 1019E 1018 11851 114901 1 1081 u G0065 1 20151 MATCH LIN E 2F' Fs University Cornell University FACILITIES INVENTORY D R A VV�q� I N G DISCLAIMER THESE DRAWINGS, AND THEIR ASSOCIATED ELECTRONIC FILES HAVE BEEN PRODUCED FOR THE PURPOSE OF SPACE INVENTORY CAMPUS BUILDINGS. FEATURES SHOWN ARE INCIDENTAL TO THEIR PURPOSE AND DEPICT CONDITIONS AT THE TIME THE DRAWINGS WERE PRODUCED. THESE DRAWINGS SHOULD NOT BE RELIED UPON FOR ANY OTHER PURPOSE. REVISIONS: 1/01101,1/02EQ, 3/02EQ, 10/04EQ, 1/18 SV 3/09 E0, 2/10 EQ, 1/14SV, 1/16 SV, DRAWN BY: JJR DRAWING NO 1 OF 6 PLAN LEVEL: G BLDG NAME'. BIOTECHNOLOGY BLDG NO'. 1018 UN/I, U G 'PpfO qui,11 h 0 L1. HUMPHREYSSERVICEBUILDING 639 DRYDEN ROAD ITHACA, NEW YORK 14853-3101 GRAPHIC SCALE, 0 5 10 20 CHECKED BY: AGE DATE, 3/17/99 TOTAL BLDG GROSS s0 FT. 173,983 P MATCH LINE MATCH TO RIGHT 189 1 14261 1791 61 1 1141 1 31 1 1681 233 1 15 1 1241 1 173 1 11491 N FIRST FLOOR PLAN GROSS AREA • 26,929 SQ. FT. 1 MATCH LIN ��--�,47: CORN DRAWING DISCLAIMER THESE DRAWINGS, AND THEIR ASSOCIATED ELECTRONIC FILES HAVE BEEN PRODUCED FOR THE PURPOSE OF SPACE INVENTORY CAMPUS BUILDINGS. FEATURES SHOWN INCIDENTAL TOTHEIPURPOSEANDDEPICTCONDITIONS CONDITIONS AT THE TIME THE DRAWINGS WERE PRODUCED. THESE DRAWINGS SHOULD NOT BE RELIED UPON FOR ANY OTHER PURPOSE. /16 SV, REVISIONS:/17 SVGI, 7/01 BL, 3/05 EO, 8/06 EQ, 1/07 EQ, 3/07 ED, DRAWN BY: JJR DRAWING NO: 2 OF 6 PLAN LEVEL: 1 BLDG NAME: BIOTECHNOLOGY BLDG NO: 1018 rri+ UNIVERSIT Y .... FACILITIES INVENTORY I J. W. HUMPHREY'S SERVICE BUILDING ITHACA, NY 14853 SCALE: 0 5 10 20 CHECKED BY: AGE DATE: 3/17/99 TOTAL BLDG GROSS SQ. FT, 173,983 260 14971 MATCH LIN 1- 20065 209 14911 207 11521 23 1 2095 14471 214 11861 L 209A 11471 212 13001 20052 13441 217C 219 221A 11471 14911 14451 2175 2218 14531 14851 V 1 168 1 12951 2951 112331 11681 1 118 12361 11471 1 152 1 11471 2811 2811 12091 120 1 1431 195 1 12031 14961 14481 11841 1 641 1 581 12801 1 147 1 1 811 111231 41 1 15741 1 94 1 14001 14491 1 10 1 1 27 1 11851 60 1 1 180 1 16031 15811 16001 14011 J 11521 11471 2291 11281 11521 11471 11241 257 14961 2575 14521 2536 14541 20048 11821 253A 11471 253 14951 20045 251 112491 11671 249 11661 245A J 11471 245 14941 53 1 2458 14501 70 1 20071 65 1 241A 11471 2418 14481 L 231 11241 233A 11471 20064 53 1 235 1471 1497j 2275 14511 2338 14531 233 14931 i 241 14951 1551 F N EDSECOND FLOOR PLAN GROSS AREA 32,562 SO. FT. - CORN DRAWING A W I N G D I S C L A I M E R THESE DRAWINGS, AND THEIR ASSOCIATED ELECTRONIC FILES HAVE BEEN PRODUCED FOR THE PURPOSE OF SPACE INVENTORY CAMPUS BUILDINGS. FEATURES SHOWN INCIDENTAL TO THEI PURPOSE AND DEPICT CONDITIONS AT THE TIME THE DRAWINGS WERE PRODUCED. THESE DRAWINGS SHOULD NOT BE RELIED UPON FOR ANY OTHER PURPOSE. REVISIONS: 9/00 EQ, 1/06 EQ, 1/07 EQ, 3/07 EQ DRAWN BY: JJR DRAWING NO: 3 OF 6 PLAN LEVEL: 2 BLDG NAME: BIOTECHNOLOGY BLDG NO: 1018 UN I V E R S 1 T Y ■`-- SCALE: 0 5 10 20 CHECKED BY: AGE DATE: 3/17/99 TOTAL BLDG GROSS SQ. FT, 173,983 161. FACILITIES INVENTORY J. W. HUMPHREY'S SERVICE BUILDING ITHACA, NY 14853 360 14981 367 14961 151 1 363 1 10 1 3605 3006230061 14501 1 27 1 1601 303 14911 14921 11531 303B 4451 119 30065 76 1 1 142 1 14471 151 1 1441 11461 1 57 1 30052 13471 1 72 1 2361 1 152 1 11481 3678 14471 367A 11471 12071 302 11841 11201 304 12041 369 1 811 371 12801 11241 306 12811 43 1 308 15981 326 2811 1 194 O 1641 1411 30040 19301 30021-1 30049 1 94 1 J 152 1 11471 14001 354 16021 1891 1 1128 1 182 1 1 147 14951 14511 14531 14961 368 11861 352 14011 370 13011 30045 112491 350 12811 w 7 351 11671 345A 11471 349 11661 345 14961 15741 11801 12281 343 11251 3455 14491 336 6001 30071 1 65 1 341A 1150.1 3415 14481 :J1/A 319 11251 321A 1 147 1 30044 112391 3178 1 3218 14531 321 14961 323 11681 327A 11471 331 11241 333A 11471 30064 53 1 335 1471 325 1 168 1 327 14961 327B 14511 333E 14531 333 14931 341 14961 1551 1 ATCH TO RIGHT N ElD THIRD FLOOR PLAN GROSS AREA 32,562 SQ. FT, T T CORD ELL DRAWING A W I N G D I S C L A I M E R THESE DRAWINGS, AND THEIR ASSOCIATED ELECTRONIC FILES HAVE BEEN PRODUCED FOR THE PURPOSE OF SPACE INVENTORY CAMPUS BUILDINGS. FEATURES SHOWN INCIDENTAL TO THEI PURPOSE AND DEPICT CONDITIONS AT THE TIME THE DRAWINGS WERE PRODUCED. THESE DRAWINGS SHOULD NOT BE RELIED UPON FOR ANY OTHER PURPOSE. REVISIONS: 1/07 EQ, 3/07 EQ DRAWN BY: JJR DRAWING NO: 4 OF 6 PLAN LEVEL: 3 BLDG NAME: BIOTECHNOLOGY BLDG NO: 1018 UNIVERSIT Y .�`-- FACILITIES INVENTORY J. W. HUMPHREY'S SERVICE BUILDING ITHACA, NY 14853 SCALE: 0 5 10 20 CHECKED BY: AGE DATE: 3/17/99 TOTAL BLDG GROSS SQ. FT, 173,983 1491 14921 14471 11461 1521 146 1 40052 13441 1 44 1 11os 1 14921 14451 EP 11391 12361 1 152 1 11481 11231 424 426 11091 15721 419 11251 421A 1 147 1 417B 40044 112481 421E 14521 421 14951 423 1 167 1 i5 12061 11201 467 14961 12031 1 43 1 11871 14471 1196J 1 281 1 147 1 1911 19341 460 14971 110 1 40021- 40049 1 94 1 449] 1261 1 60 1 11801 11521 147] 123 1 152 1 1 147 1 1 125 1 457 14941 4578 4511 4538 14531 14011 427A 11471 431 11241 433A 11471 425 11691 427 14961 4278 14511 11861 11891 13011 1631 16031 40020 1 89 1 1 991 453A 11471 453 14951 40045 451 1701 12531 1761 449 11691 12801 11471 12281 1 65 1 11471 1 125 1 11491 11551 445 14961 445E 14491 4418 14481 441 14951 4338 14531 433 14931 ATCH TO RIGHT N ED FOURTH FLOOR PLAN GROSS AREA = 32,562 SQ. FT. ELL CORN ELL DRAWING A W I N G D I S C L A I M E R THESE DRAWINGS, AND THEIR ASSOCIATED ELECTRONIC FILES HAVE BEEN PRODUCED FOR THE PURPOSE OF SPACE INVENTORY CAMPUS BUILDINGS. FEATURES SHOWN INCIDENTAL TO THEI PURPOSE AND DEPICT CONDITIONS AT THE TIME THE DRAWINGS WERE PRODUCED. THESE DRAWINGS SHOULD NOT BE RELIED UPON FOR ANY OTHER PURPOSE. REVISIONS: 1/06 EO, 1/07 EO, 3/0] EO, 2/17 SV DRAWN BY: JJR DRAWING NO: 5 OF 6 PLAN LEVEL:BLDG 4 NAME: BIOTECHNOLOGY BLDG NO: 1018 UNIVERSIT Y .�`-- FACILITIES INVENTORY J. W. HUMPHREY'S SERVICE BUILDING ITHACA, NY 14853 SCALE: 0 5 10 20 CHECKED BY: AGE DATE: 3/17/99 TOTAL BLDG GROSS SQ. FT, 173,983 1/8.. . . 18-060 Biotech ECI Pneumatic ReplacemntIthaca, NY 14850As Prepared By:T: 585.424.5340PROJECT TEAMClient Name:Owner:Design Engineer:Project Number:Drawing Designation:Project Manager:Drawing Date:Cornell UniversityRon Hurd18-060SubmittalNeil Comstra9/27/2018F: 585.424.5369Architect:MEP Engineer: ME EngineeringConsulting Engineer:Construction Manager:Rich GostlingDarlene HackworthGeneral Contractor:Mechanical Contractor:Logical Control SolutionsKimble MechanicalVictor, NY 145641. All drawings are schematic. Controls electrical contractor is responsible for coordination of all work. Refer to architectural drawings for exact locations of building structural elements. Coordinate all equipment locations; concealment and surface finish treatments carefully with work of all trades. In any case of discrepancy between the plans or in any case where such issues require clarification, notify engineer.2. Refer to contract drawings and specs for further information.3. Pathways by controls electrical contractor.4. Cutting and patching is responsibility of controls electrical contractor.5. Existing system must remain online.6. All panels must meet standard contained in this drawing set.7. Controls electrical contractor is required to provide as-built sketch similar to the ones contained in this drawing set. All pipe runs, panel locations, device locations, junction boxes, etc. shall be accurately documented by electrical controls subcontractor. Final as-built drawings to be provided by LCS.Sales Engineer: Bob Hilton829 Phillips Road DRAWING NO.: TOC.1DRAWING#DRAWING NAMETOC.1 Table of ContentsSYM.1 Symbol LegendINSTALL.1 Installation NotesWIRE.1 Wire Specification0.1.1 Riser 3/40.1.2 Riser 1/20.1.3 Riser Ground1.1.0 ACS-4/EF-41.2.0 MR and Transformer Rm Ventilation3.1.1 Config-A SVAV w/ Reheat, FTR, T, and Occ3.1.2 Config-B SVAV w/ Reheat, T, and EVAV3.1.3 Config-F SVAV w/ Reheat, FTR, T, and EVAV3.2.0 Equipment Rooms w/FCU7.1.1 Reheat Valves-17.1.2 Reheat Valves-27.1.3 Reheat Valves-37.1.4 FTR Valves7.1.5 FCU CW ValvesDETAILS.1DETAILS.2 DRAWING NO.:TAG DESCRIPTIONSAA Remote Annunciator Module & Auto Dialer P Pressure ProbeALC Automated Logic Controller PDS Pressure Differential SwitchASA Smoke Detector PDT Pressure Differential TransmitterCR Control Relay PS Pressure SwitchENC Enclosure PT Pressure TransmitterES Direct Current Power Supply QT Gas TransmitterFCV Flow Control Valve / Damper Actuator ST Speed TransmitterFE Flow Element SUB Subpanel FS Flow Switch TE Temperature ElementFT Flow Transmitter TS Temperature SwitchG Generic Device TSH Temperature Switch HighIP Electro-Pneumatic Transducer TSL Temperature Switch LowIS Current Switch TT Temperature TransmitterISE Circuit Breaker TY Dew Pt./Enthaply/Wet Bulb TransducerIT Current Transducer V ValveJT BTU Meter VT Vibration Transmitter / SwitchJY Power Meter X UnclassifiedKS Electronic Timeclock XF TransformerLS Level Switch YKS Position TransmitterLT Level Transmitter YL Position TransmitterMS Humidistat YS Leak DetectorMT Humidity Transmitter YSE Emergency StopMTE Humidity Transmitter w/ Temperature Element YY TransducerMTT Humidity Transmitter w/ Temperature Transmitter ZS Position Indicating SwitchN Accessories ZT Position TransmitterNY Network DeviceTE-#Field Mounted InstrumentLEGENDPneumatic TubingLine Voltage WireMiscellaneous NotationsFLP = Fails At Last PositionFC = Fails ClosedFO = Fails OpenLHigh Voltage TerminalLow Voltage TerminalWire ColorShield PigtailCable Masterto ControllerCable NumberShieldCable Slave to Field DeviceLow Voltage ConnectionX1Modbus120 Ohm End of Line Resistor, 1/4 Watt, +/- 1%BACNet MS/TPPlug-In EOL Terminator & Bias Amplifier for ARC156 NetworkEthernet (Cat 6 RJ45 Cable)ARC156 Fiber Optic Cable120 ΏBT485LEGENDWHTBLK(1.0,B1)C-102WHTBLK(1.0,C1)C-102Page # of MateGrid Location of MateCable NumberPage # of MateGrid Location of MateREDBLK(SYM.1,A5)C-104REDBLK(SYM.1,A4)C-103REDBLK(SYM.1,A5)C-105BUBBLE SHAPE LEGENDTRIANGLE: This cable extends from one field/panel device to another.REDBLK(SYM.1,C4)C-104OVAL: This cable extends directly from the ALC Controller/device.REDBLK(SYM.1,C4)C-103RECTANGLE: This cable extends from a field device to a terminal block within a panel.REDBLK(SYM.1,B4)C-10524VACPAGE NUMBERING0 – Network Riser/Devices1 – Air Handling Equipment2 – Hydronic Systems3 – Terminal Equipment4 – Lab Equipment5 – Integration6 – Miscellaneous7 – Hydronic Valve Schedule8 – Damper Schedule9 – Metering10 – Air Valves DRAWING NO.: Installation NotesAll communication cable, terminations "in" an "out" of a field module panel, terminal equipment or VAV's must be labeled with "from (equipment name)" and "to (equipment name)" locations. See Figure 1 below.All ARC156 or UNet communication, serial interface, control, and monitoring wiring must be terminated at the locations designated and must be free of splices.When stripping multi-conductor cables, use only strippers specifically designed for removal of outer sheath insulation so as not to damage the shielding or insulation of the conductors. Use Ideal Catalog #45-514 or #45-165 data cable strippers or equivalent.When shielded cable is used, do not strip back sheath more than 1" in order to keep twisted pair from separating. Do not ground shield to the panel or chassis ground. The shield should only be connected to the 'Optional Shield' connection at a module. Ungrounded shields must be cut back and taped to prevent contact with with metal surfaces (heat shrink is preferred). See figure 2 below.Multi-conductor cabling other than specified or pre-approved by the System and Service Provider (SSP) is unacceptable. Electrical installation shall be in accordance with the project specifications, national, state, and local electrical codes along with ALC standards as outlined in this and other documents.Room temperature sensors shall be mounted 48 inches above the finished floor per the Americans with Disabilities Act or as specified in contract documents.All pneumatic tubing that exceeds ten feet in length must be rigid copper or poly tubing installed in conduit. All poly tubing in exposed areas must be installed in conduit. Use plenum rated poly tubing for runs made in hung ceilings. Short lengths of less than 16 inches are permitted to be exposed for connection to field devices.All field module panels (FMPs) will have a dedicated 120vac circuit.Figure 1.Shield-+From VAV-3To VAV-5VAV-3VAV-5Equipment NameARC156 or UNet termination point in FMP or Terminal EquipmentFigure 2.1"1/4"FoilInner InsulationOuterJacketNOTES: • The network order MUST be documented on network riser. • A PROT485 must be installed in series with ARCnet network after every (5) control modules • End of line BT485 termination shall be installed at the start and on the last card on a network.• 120 Ω resistor shall be installed across (+) and (-) terminals at the start and on the last device on MSTP/BACnet Network• The total VA must not exceed 80% on a 100VA circuit. • ex. Qty. 4 (ZN220 = 20VA) = 80 VA, Max Qty. of ZN220s on 100VA Circuit = 4• The 24V power designations MUST be documented in network riser. ex. PS B – 1 – 2 FloorPower Supply NumberCircuit onPower SupplyPower Supply DRAWING NO.:AbbreviationsAWG - American Wire GaugeCAT-6 - Ethernet CableG or GND - GroundI/O - Input/OutputNET- - ARCnet comm. -NET+ - ARCnet comm. +ST - Fiber Optic ConnectorTHHN - A thermoplastic-insulated, nylon-jacketed conductor designed for use in dry locations and an operating temperature of up to 90 degrees Celsius.VAC - Voltage, Alternating CurrentVDC - Voltage, Direct CurrentCABLE SPECIFICATIONS AND ABBREVIATIONSCable Line TypesWire TypeTypical ApplicationColorRedBlack18 AWG 2 Conductor Bare Copper, Plenum Rated24 VAC/VDC WiringRedBlackWhiteBlackARC156 (no power wire)22 AWG 2 Conductor Tinned Copper, Plenum Rated, Low CapacitanceARC156-BOX (Green Jacket) ShieldedPr.1 White/Blue & BluePr.2 White/Orange&OrangePr.3 White/Green & GreenPr.4 White/Brown & BrownEthernet23 AWG 4 Pair CAT 6, Plenum RatedW244P-2274BL CAT 6W183C-2052-## 12 AWG THHN18 AWG THHNW181P-2051W-ORG 002370-S (White Jacket)24 VAC/VDC Internal Panel Wiring120 VAC Power Wiring442364 (White Jacket Orange Stripe)LCSEPARTS.COMWindy City Wire Part Number’sW181C-1396#Not Specified031801 (Red)0318011 (Black)0312010 (White)0312011 (Black)031206 (Green)18 AWG 3 Conductor Bare Copper, Plenum Rated043006AL (Green Jacket) Shielded043005AL (Purple Jacket) ShieldedRedBlackWhite556609-S (Blue Jacket) CAT 6I/O WiringWhiteBlackGreenRnetW184C-2099# (Yellow Jacket)RedBlackWhiteGreenNotes:1. If a wire substitution is made consult LCS for approval.2. If ordering from Logical Control Solutions use: LCSEPARTS.com3. If ordering from Windy City contact: Bill Stang – 800.379.119118-1C12-1C18-PWR18 AWG 2 Conductor Bare Copper, Plenum RatedI/O WiringWhiteBlackW181P-2051-White002360 (White Jacket)18-2CCAT6W181P-2040W-# Shielded002320 (White Jacket) ShieldedS18-2CW181P-2040W-# Shielded442324 (White Jacket Orange Stripe) ShieldedS18-PWR18-3CS18-3CW183C-2058-## Shielded002330-S (White Jacket) ShieldedW184C-2099-## RedBlackWhiteGreenI/O Wiring002380-S (White Jacket)18 AWG 4 Conductor Bare Copper, Plenum Rated18-4CS18-4CW184C-2059-## Shielded002340-S (White Jacket) ShieldedW1818C-2046-.5RIBRed BlackWhite GreenBrown BlueYellow OrangeI/O Wiring002392-S (White Jacket18 AWG 8 Conductor Bare Copper, Plenum Rated18-8CS18-8CW188C-2030-# Shielded002352-S (White Jacket) ShieldedARC156White/Blue & Blue/WhiteWhite/Orange & Orange/WhiteABB ACH550 VSD(2) pair 24AWG (2) Shielded, Plenum RatedBelden 9842 or EqualS24-2PBelden 9842 or Equal18 AWG 4 Conductor Bare Copper, Plenum RatedRNETSRNETW184C-2059# (Yellow Jacket) Shielded0023830 (Yellow Jacket)0023430 (Yellow Jacket) Shielded 00000 DRAWING NAME:Riser 3/4PROJECT:18-060 Biotech ECI Pneumatic ReplacemntIthaca, NY 14850CONTRACT NO: 18-060REVDESCRIPTIONDATEBYFILENAME: 0.1 Network RiserDE: RDHRiser 3/4SE:Bob Hilton829 Phillips RoadVictor, NY 14564ABCDEFGH1234512345PR: Cable ReferenceModbus120 Ohm End of Line Resistor, 1/4 Watt, +/- 1%BACNet MS/TPPlug-In EOL Terminator & Bias Amplifier for ARC156 NetworkEthernet (Cat 6 RJ45 Cable)ARC156 Fiber Optic Cable120 ΏBT4851. The BMS Riser is intended only to provide an overview of the system architecture. DDC devices are not intended to be wired in exactly the order shown. Optimal wiring runs to be determined in field.2. All devices are to be wired in a daisy chain configuration.3. Network numbers are placeholders and will be coordinated with the owner.4. If equipment being served is on EM power or is expected to function during a power outage then the controller must be on EM power.5. DO NOT change controller addresses.6. Installer required to keep documentation of ACTUAL path of network wire and ACTUAL path of power wire. This information will be incorporated into as-builts.7. All panels and power supplies must be installed in accessible locations.8. BT485's are installed at each end of network, not necessarily at the controllers shown above.9. VA draw per circuit cannot exceed 80% of total VA available. Typically this results in 4 or 5 controller per 100VA circuit.Notes:DRAWING NO.: 0.1.1DRAWING NO.: 0.1.1BT485ALC-13rd Floor30067G5RE PanelEthernetARC156/MSTPMSTPG5REMAC: 1 IP: 120 VACAAR-4-1MAC: 2 AAR-4-2MAC: 3 AAR-4-3MAC: 4 EthernetARC156/MSTPMSTPG5REMAC: 1 IP: AAR-3-1MAC: 2 AAR-3-2MAC: 3 AAR-3-3MAC: 4 4th Floor401ZN341v+MAC: 406ZN141v+MAC: 416ZN341v+MAC: 435ZN341v+MAC: 439ZN341v+MAC: 458ZN341v+MAC: 459ZN341v+MAC: 469ZN341v+MAC: 408ZN141v+MAC: 412ZN141v+MAC: 414ZN141v+MAC: 424ZN141v+MAC: 430AZN141v+MAC: 430BZN141v+MAC: 469ZN141v+MAC: 470ZN141v+MAC: 473ZN141v+MAC: 428ZN253MAC: 434ZN253MAC: 450ZN253MAC: 456ZN253MAC: 120/240VAC132XF-124VACCom24VACCom24VACComLN100 VA100 VA100 VAG120/240VAC132XF-224VACCom24VACCom24VACComLN100 VA100 VA100 VAG335ZN341v+MAC: 339ZN341v+MAC: 358ZN341v+MAC: 359ZN341v+MAC: 365ZN341v+MAC: 311ZN141v+MAC: 312ZN141v+MAC: 314ZN141v+MAC: 326ZN141v+MAC: 330ZN141v+MAC: 330AZN141v+MAC: 330BZN141v+MAC: 352ZN141v+MAC: 368ZN141v+MAC: 369ZN141v+MAC: 308ZN253MAC: 334ZN253MAC: 350ZN253MAC: 354ZN253MAC: 120/240VAC132XF-324VACCom24VACCom24VACComLN100 VA100 VA100 VAG120/240VAC132XF-424VACCom24VACCom24VACComLN100 VA100 VA100 VAGNetwork layout and controller addresses to be determined as we insert new controllers into the existing networkNetwork layout and controller addresses to be determined as we insert new controllers into the existing network 00000 DRAWING NAME:Riser 1/2PROJECT:18-060 Biotech ECI Pneumatic ReplacemntIthaca, NY 14850CONTRACT NO: 18-060REVDESCRIPTIONDATEBYFILENAME: 0.1 Network RiserDE: RDHRiser 1/2SE:Bob Hilton829 Phillips RoadVictor, NY 14564ABCDEFGH1234512345PR: Cable ReferenceModbus120 Ohm End of Line Resistor, 1/4 Watt, +/- 1%BACNet MS/TPPlug-In EOL Terminator & Bias Amplifier for ARC156 NetworkEthernet (Cat 6 RJ45 Cable)ARC156 Fiber Optic Cable120 ΏBT4851. The BMS Riser is intended only to provide an overview of the system architecture. DDC devices are not intended to be wired in exactly the order shown. Optimal wiring runs to be determined in field.2. All devices are to be wired in a daisy chain configuration.3. Network numbers are placeholders and will be coordinated with the owner.4. If equipment being served is on EM power or is expected to function during a power outage then the controller must be on EM power.5. DO NOT change controller addresses.6. Installer required to keep documentation of ACTUAL path of network wire and ACTUAL path of power wire. This information will be incorporated into as-builts.7. All panels and power supplies must be installed in accessible locations.8. BT485's are installed at each end of network, not necessarily at the controllers shown above.9. VA draw per circuit cannot exceed 80% of total VA available. Typically this results in 4 or 5 controller per 100VA circuit.Notes:DRAWING NO.: 0.1.21st Floor100651st Floor AAR PanelAAR-1-1MAC: 2 AAR-1-2MAC: 3 AAR-1-3MAC: 4 2nd Floor207ZN341v+MAC: 210ZN141v+MAC: 216ZN341v+MAC: 235ZN341v+MAC: 239ZN341v+MAC: 258ZN341v+MAC: 259ZN341v+MAC: 265ZN341v+MAC: 212ZN141v+MAC: 214ZN141v+MAC: 230ZN141v+MAC: 230AZN141v+MAC: 230AZN141v+MAC: 230BZN141v+MAC: 236ZN141v+MAC: 240ZN141v+MAC: 234ZN253MAC: 254ZN253MAC: 135ZN341v+MAC: 139ZN341v+MAC: 158ZN341v+MAC: 159ZN341v+MAC: 167ZN341v+MAC: 150ZN253MAC: 120/240VAC132XF-224VACCom24VACCom24VACComLN100 VA100 VA100 VAG20672nd Floor AAR PanelAAR-2-1MAC: 2 AAR-2-2MAC: 3 AAR-2-3MAC: 4 LGR25 is located in G0068LGR25 is located in G0068120/240VAC15432XF-124VACCom24VACCom24VACCom24VACCom24VACComLN100 VA100 VA100 VA100 VA100 VAGNetwork layout and controller addresses to be determined as we insert new controllers into the existing networkNetwork layout and controller addresses to be determined as we insert new controllers into the existing network 00000 DRAWING NAME:Riser GroundPROJECT:18-060 Biotech ECI Pneumatic ReplacemntIthaca, NY 14850CONTRACT NO: 18-060REVDESCRIPTIONDATEBYFILENAME: 0.1 Network RiserDE: RDHRiser GroundSE:Bob Hilton829 Phillips RoadVictor, NY 14564ABCDEFGH1234512345PR: Cable ReferenceModbus120 Ohm End of Line Resistor, 1/4 Watt, +/- 1%BACNet MS/TPPlug-In EOL Terminator & Bias Amplifier for ARC156 NetworkEthernet (Cat 6 RJ45 Cable)ARC156 Fiber Optic Cable120 ΏBT4851. The BMS Riser is intended only to provide an overview of the system architecture. DDC devices are not intended to be wired in exactly the order shown. Optimal wiring runs to be determined in field.2. All devices are to be wired in a daisy chain configuration.3. Network numbers are placeholders and will be coordinated with the owner.4. If equipment being served is on EM power or is expected to function during a power outage then the controller must be on EM power.5. DO NOT change controller addresses.6. Installer required to keep documentation of ACTUAL path of network wire and ACTUAL path of power wire. This information will be incorporated into as-builts.7. All panels and power supplies must be installed in accessible locations.8. BT485's are installed at each end of network, not necessarily at the controllers shown above.9. VA draw per circuit cannot exceed 80% of total VA available. Typically this results in 4 or 5 controller per 100VA circuit.Notes:DRAWING NO.: 0.1.3Ground FloorNetwork layout and controller addresses to be determined as we insert new controllers into the existing networkG0068EthernetARC156Port S2Port S1LGR25MAC: IP: EthernetARC156Port S2Port S1LGR25MAC: IP: EthernetARC156Port S2Port S1LGR25MAC: IP: -G-1-2G40ZN141v+MAC: G41ZN141v+MAC: G45ZN141v+MAC: G50ZN141v+MAC: G50BZN141v+MAC: G50CZN141v+MAC: G50DZN141v+MAC: G52ZN141v+MAC: G52BZN141v+MAC: G54AZN141v+MAC: G63ZN141v+MAC: G65ZN141v+MAC: G67ZN141v+MAC: G68ZN141v+MAC: G57ZN341v+MAC: G59ZN341v+MAC: 120/240VAC15432XF-124VACCom24VACCom24VACCom24VACCom24VACComLN100 VA100 VA100 VA100 VA100 VAGExistingTag Part Number Product Description Manufacturer Panel/Field QuantityXF-1 PSH300A Enclosed 300VA Pwr Supply, 3x100VA Circuits Functional Devices P 1XF-1 PSH500A Enclosed 500VA Pwr Supply, 5x100VA Circuits Functional Devices P 1XF-1 PSH500A Enclosed 500VA Pwr Supply, 5x100VA Circuits Functional Devices P 1XF-2 PSH300A Enclosed 300VA Pwr Supply, 3x100VA Circuits Functional Devices P 1XF-2 PSH300A Enclosed 300VA Pwr Supply, 3x100VA Circuits Functional Devices P 1XF-3 PSH300A Enclosed 300VA Pwr Supply, 3x100VA Circuits Functional Devices P 1XF-4 PSH300A Enclosed 300VA Pwr Supply, 3x100VA Circuits Functional Devices P 1ALC-1 BT485 ARCNET156 Terminating and Biasing plug in board (16 Pk) Automated Logic P 0Bill of Material 00000 DRAWING NAME:ACS-4/EF-4PROJECT:18-060 Biotech ECI Pneumatic ReplacemntIthaca, NY 14850CONTRACT NO: 18-060REVDESCRIPTIONDATEBYFILENAME: 1.1 AHU'sDE: RDHACS-4/EF-4SE:Bob Hilton829 Phillips RoadVictor, NY 14564ABCDEFGH1234512345PR: DRAWING NO.: 1.1.0ShieldAI 1 : Signal, 0-10V+24VDCDI 1: Start/Stop+24VDCAI 1 : CommonVFD - ABB ACH550E-Clipse Bypass Control BoardX1X2DI 3: Safety InterlockB+ PositiveA- NegativeAGNDSCRSCRAO 1 : Signal, 4-20 mAAO 2 : Signal, 4-20mAAO : CommonR02: VFD Running CommonR02: VFD Running N.O.R03: VFD Alarm Common25242298732175212928272630DI CommonGND43R03: VFD Alarm N.C.26From AO-3 on existing SE6166To UI:14 on existing SE6166 4-20maNew NewExisting ALC controlled AHU in Ground Floor MRNØCNOCNOStatusIS-1Relay24ac/dc Coil18-4CREDBLK(1.1.0,A4)C-2WHTGRN(1.1.0,A5)C-3REDBLK(1.1.0,A4)C-2WHTGRN(1.1.0,A4)C-3From BO-1 on existing SE6166To UI:9 on existing SE6166 Dry ContactSupply AirOutdoor Air ACS-4VFDDRYDRYCOMOUTEXCHiLoREDBLK(1.1.0,G3)C-206WHTGRN(1.1.0,G3)C-101MAC:1ZN551CONTROLLERAO-1EF Speed, 0-10V21Gnd+DO-1EF Start/Stop, NO2BUS1DO-2, NO3DO-3, NO4DO-4, NO5DO-5, NO6ShieldNet-Net+123CMnetGnd24V ac21Point Name Rnet, RNETRn+GndRn-12+12V43RnetGnd14LEDIN-4, Th/DC2IN-5, Th/DC3LStat PortIN-1EF-1 Status, Th/DC12+GndIN-2EF Static Press, 0-5V34+GndIN-3, Th/DC56+GndALC-1Therm/Dry0-5VIN-1Therm/Dry0-5VIN-218-PWR24VACCOM-1See Riser Diagram for Address and Pwr assignmentsArcnet Com. Bus INAs per Riser DiagramArcnet Com. Bus OUTAs per Riser DiagramBlkWht24VACCOM-1REDBLK(1.1.0,G2)C-201WHTBLKRED(1.1.0,F3)C-10224VACCOM-1Existing EF in Penthouse MRNewExhaust AirExhaust AirDRYDRYCOMOUTEXCHiLo EF-4VFDShieldAI 1 : Signal, 0-10V+24VDCDI 1: Start/Stop+24VDCAI 1 : CommonVFD - ABB ACH550E-Clipse Bypass Control BoardX1X2DI 3: Safety InterlockB+ PositiveA- NegativeAGNDSCRSCRAO 1 : Signal, 4-20 mAAO 2 : Signal, 4-20mAAO : CommonR02: VFD Running CommonR02: VFD Running N.O.R03: VFD Alarm Common25242298732175212928272630DI CommonGND43R03: VFD Alarm N.C.26NØCNOCNOStatusIS-2Relay24ac/dc Coil18-4CREDBLK(1.1.0,F5)EF Start/StopC-206WHTGRN(1.1.0,E4)EF-1 StatusC-101REDBLK(1.1.0,F4)EF SpeedC-201WHTBLKRED(1.1.0,E4)EF Static PressC-102NewNewTag Part Number Product Description Manufacturer Panel/Field QuantityIS-1 CSCGA2125R1 Current Switch w/Relay, Split Core, Adj. 1.25-135 Amp, 10A@260 VAC, 5A@30VDC, SPST Setra F 1IS-2 CSCGA2125R1 Current Switch w/Relay, Split Core, Adj. 1.25-135 Amp, 10A@260 VAC, 5A@30VDC, SPST Setra F 1PDT-1 MRGPA Field Selectable 0.5" to 5.0"; Outputs(0-5Vdc, 0-10Vdc, 4-20mA) Duct Probe, 1/2' Conduit Setra F 1PDT-2 MRGPA Field Selectable 0.5" to 5.0"; Outputs(0-5Vdc, 0-10Vdc, 4-20mA) Duct Probe, 1/2' Conduit Setra F 1ALC-1 ZN551 Zone Controller, 5DO, 5UI, 1AO Automated Logic P 1Bill of Material18-3C18-2C 00000 DRAWING NAME:MR and Transformer Rm VentilationPROJECT:18-060 Biotech ECI Pneumatic ReplacemntIthaca, NY 14850CONTRACT NO: 18-060REVDESCRIPTIONDATEBYFILENAME: 1.1 AHU'sDE: RDHMR and Transformer Rm VentilationSE:Bob Hilton829 Phillips RoadVictor, NY 14564ABCDEFGH1234512345PR: DRAWING NO.: 1.2.0DRAWING NO.: 1.2.0ShieldAI 1 : Signal, 0-10V+24VDCDI 1: Start/Stop+24VDCAI 1 : CommonVFD - ABB ACH550E-Clipse Bypass Control BoardX1X2DI 3: Safety InterlockB+ PositiveA- NegativeAGNDSCRSCRAO 1 : Signal, 4-20 mAAO 2 : Signal, 4-20mAAO : CommonR02: VFD Running CommonR02: VFD Running N.O.R03: VFD Alarm Common25242298732175212928272630DI CommonGND43R03: VFD Alarm N.C.26NewNØCNOCNOStatusIS-1Relay24ac/dc Coil18-4CREDBLK(1.2.0,F5)EF Start/StopC-204WHTGRN(1.2.0,E4)SF StatusC-101REDBLK(1.2.0,A4)C-204WHTGRN(1.2.0,A4)C-101Supply AirOutdoor Air SFVFDShieldAI 1 : Signal, 0-10V+24VDCDI 1: Start/Stop+24VDCAI 1 : CommonVFD - ABB ACH550E-Clipse Bypass Control BoardX1X2DI 3: Safety InterlockB+ PositiveA- NegativeAGNDSCRSCRAO 1 : Signal, 4-20 mAAO 2 : Signal, 4-20mAAO : CommonR02: VFD Running CommonR02: VFD Running N.O.R03: VFD Alarm Common25242298732175212928272630DI CommonGND43R03: VFD Alarm N.C.26NØCNOCNOStatusIS-2Relay24ac/dc Coil18-4CREDBLK(1.2.0,F5)SF Start/StopC-205WHTGRN(1.2.0,E4)EF StatusC-102REDBLK(1.2.0,G3)C-205WHTGRN(1.2.0,G3)C-10218-PWR24VACCOM-1See Riser Diagram for Address and Pwr assignmentsArcnet Com. Bus INAs per Riser DiagramArcnet Com. Bus OUTAs per Riser DiagramBlkWht24VACCOM-1REDBLK(1.2.0,G1)C-202REDBLK(1.2.0,F4)EF SpeedC-202NewMAC:1ZN253CONTROLLERAO-1SF Speed, 0-10V21Gnd+DO-1SF Start/Stop, NO2BUS1DO-2EF Start/Stop, NO3ShieldNet-Net+123CMnetGnd24V ac21Zone Temp, RNETRn+GndRn-12+12V43RnetGnd14LEDIN-4, Th/DC2IN-5, Th/DC3LStat PortIN-1SF Status, Th/DC12+GndIN-2EF Status, Th/DC34+GndIN-3, Th/DC56+GndALC-1AO-2EF Speed, 0-10V43Gnd+AO-3, 0-10V65Gnd+Therm/Dry0-5VIN-1Therm/Dry0-5VIN-2REDBLK(1.2.0,A2)C-203REDBLK(1.2.0,F4)SF SpeedC-203Typical For:MR G0064TR G0065Typical of 2TE-1Net+Net-+12VGndMANUAL ON WARMER INFO COOLERAUTOMATED LOGICWHTBLKREDGRN(1.2.0,C4)C-100WHTBLKREDGRN(1.2.0,E4)Zone TempC-100Exhaust AirExhaust Air EFVFDNew18-4CENC-1Tag Part Number Product Description Manufacturer Panel/Field QuantityIS-1 CSCGA2125R1 Current Switch w/Relay, Split Core, Adj. 1.25-135 Amp, 10A@260 VAC, 5A@30VDC, SPST Setra F 2IS-2 CSCGA2125R1 Current Switch w/Relay, Split Core, Adj. 1.25-135 Amp, 10A@260 VAC, 5A@30VDC, SPST Setra F 2ALC-1 ZN253 Zone Controller, 2DO, 5UI, 3AO Automated Logic P 2TE-1 ZS2P-ALC ZS2 Pro Space Temp Sensor, Rnet, LCD, SP Adj, Ovrd Automated Logic F 2ENC-1 CSE9929x9x2 Enclosure Versa Products Inc. F 2Bill of Material18-2C18-2C KRC5/8/20180000 Submittal0 DRAWING NAME:Config-A SVAV w/ Reheat, FTR, T, and OccPROJECT:18-060 Biotech ECI Pneumatic ReplacemntIthaca, NY 14850CONTRACT NO: 18-060REVDESCRIPTIONDATEBYFILENAME: 3.1 VAV'sDE: RDHConfig-A SVAV w/ Reheat, FTR, T, and OccSE:Bob Hilton829 Phillips RoadVictor, NY 14564ABCDEFGH1234512345PR: DRAWING NO.: 3.1.1Typical of 23Typical For:139 207 335 401158 216 339 416159 235 358 435167 239 359 439258 365 458259 459265 465Fin Tube RadiationHWSHWRFLP312WhtBlkRedV-218-3CSupply Airfrom AHUSupply AirTo SpaceVAV Box EnclosureProvided by Box Mfr.Arcnet Com. Bus INAs per Riser DiagramArcnet Com. Bus OUTAs per Riser DiagramVAV BoxWhtBlkARC15618-2C24VacAs per Riser DiagramRedBlkARC15618-2CHWSHWRHCFLP312WhtBlkRedV-118-3CTT18-2C24VACREDBLK(3.1.1,E1)C-101REDBLK(3.1.1,D4)Supply Air TemperatureC-101MANUAL ON WARMER INFO COOLERAUTOMATED LOGICTE-2Net+Net-+12VGndWHTBLKREDGRN(3.1.1,G3)C-100WHTBLKREDGRN(3.1.1,D4)Zone TempC-100S18-4CMAC:1ZN341ACONTROLLERAir FlowBACnet®HighLowAO-1Reheat Valve, 0-10V21Gnd+ShieldNet-Net+123BACnetDataGnd21Act NetPwr3Zone Temp, RNETRn+GndRn-12+12V43RnetRnetIN-3, Th/DC2IN-4, Th/DC3IN-2, Th/DC34+GndALC-1BO-3, NO4BUS1++Gnd14LEDLStat PortIN-1Supply Air Temperature, Th/DC12+GndTherm/Dry0-5VIN-1IN-2Therm/Dry0-5VGnd24V ac21PowerBO-2Valve Close, NO3BO-1Valve Open, NO2WHTBLKRED(3.1.1,E2)C-202WHTBLKRED(3.1.1,D3)Reheat ValveC-202COM-1WHTBLKRED(3.1.1,G4)C-201WHTBLKRED(3.1.1,C3)Valve OpenC-201ZS w/Motion SensorTag Part Number Product Description Manufacturer Panel/Field QuantityALC-1 ZN341A Zone Controller for VAV w/ Actuator, 3DO, 4UI, 1AO Automated Logic F 23TE-2 ZS2P-M-ALC ZS2 Pro Space Temp & Motion, Rnet, LCD, SP Adj. Ovrd Automated Logic F 23TE-1 ALC/10K-2-D-8"-BB4 Duct, 8" Insertion, BAPI Box 4 IP44 BAPI F 23V-1 See Valve Schedule See Valve Schedule See Valve Schedule F 23V-2 See Valve Schedule See Valve Schedule See Valve Schedule 23Bill of Material KRC5/8/20180000 Submittal0 DRAWING NAME:Config-B SVAV w/ Reheat, T, and EVAVPROJECT:18-060 Biotech ECI Pneumatic ReplacemntIthaca, NY 14850CONTRACT NO: 18-060REVDESCRIPTIONDATEBYFILENAME: 3.1 VAV'sDE: RDHConfig-B SVAV w/ Reheat, T, and EVAVSE:Bob Hilton829 Phillips RoadVictor, NY 14564ABCDEFGH1234512345PR: DRAWING NO.: 3.1.2Supply Airfrom AHUSupply AirTo SpaceArcnet Com. Bus INAs per Riser DiagramArcnet Com. Bus OUTAs per Riser DiagramVAV BoxWhtBlkARC15618-2CTypical of 4224VacAs per Riser DiagramRedBlkARC15618-2CHWSHWRHCFLP312WhtBlkRedV-118-3CTT18-2CTypical For:G40 G50C G63 210 230B 311 330A 406 430AG41 G50D G65 212 236 312 330B 408 430BG45 G52 G67 214 240 314 352 412 469G50 G52B G68 230 326 368 414 470G50B G54A 230A 330 369 424 47324VACREDBLK(3.1.2,C1)C-101REDBLK(3.1.2,B5)Supply Air TemperatureC-101TE-2Net+Net-+12VGndWHTBLKREDGRN(3.1.2,D2)C-100WHTBLKREDGRN(3.1.2,B5)Zone TempC-100S18-4CNote: Cable shields not shown on panel end.Exhaust Air from SpaceExhaust AirVAV Box EnclosureProvided by Box Mfr.WHTBLKRED(3.1.2,C2)C-201WHTBLKRED(3.1.2,B3)Reheat ValveC-201MAC:1ZASF-ACONTROLLERAir FlowBACnet®HighLowDataGnd21Act NetPwr3ALC-2REDBLKWHT(3.1.2,G3)C-1REDBLKWHT(3.1.2,C3)C-1MAC:1ZN141ACONTROLLERAir FlowBACnet®HighLowAO-1Point Name 1, 0-10V21Gnd+ShieldNet-Net+123BACnetDataGnd21Act NetPwr3Point Name Rnet, RNETRn+GndRn-12+12V43RnetRnetIN-3Point Name 3, Th/DC2IN-4Point Name 4, Th/DC3IN-2Point Name 2, Th/DC34+GndALC-5BO-1Point Name 1, NO2BUS1++Gnd14LEDLStat PortIN-1Point Name 1, Th/DC12+GndTherm/Dry0-5VIN-1IN-2Therm/Dry0-5VGnd24V ac21PowerMANUAL ON WARMER INFO COOLERAUTOMATED LOGICZS w/Motion SensorTag Part Number Product Description Manufacturer Panel/Field QuantityALC-2 ZASF-A VAV Airflow Sensor, Actuator, for Dual Duct Automated Logic F 42ALC-5 ZN141A Zone Controller for VAV w/ Actuator, 1DO, 4UI, 1AO Automated Logic F 42TE-2 ZS2P-ALC ZS2 Pro Space Temp Sensor, Rnet, LCD, SP Adj, Ovrd Automated Logic F 42TE-1 ALC/10K-2-D-8"-BB4 Duct, 8" Insertion, BAPI Box 4 IP44 BAPI F 42V-1 See Valve Schedule See Valve Schedule See Valve Schedule F 42Bill of Material KRC5/8/20180000 Submittal0 DRAWING NAME:Config-F SVAV w/ Reheat, FTR, T, and EVAVPROJECT:18-060 Biotech ECI Pneumatic ReplacemntIthaca, NY 14850CONTRACT NO: 18-060REVDESCRIPTIONDATEBYFILENAME: 3.1 VAV'sDE: RDHConfig-F SVAV w/ Reheat, FTR, T, and EVAVSE:Bob Hilton829 Phillips RoadVictor, NY 14564ABCDEFGH1234512345PR: DRAWING NO.: 3.1.3DRAWING NO.: 3.1.3Supply Airfrom AHUSupply AirTo SpaceVAV Box EnclosureProvided by Box Mfr.Arcnet Com. Bus INAs per Riser DiagramArcnet Com. Bus OUTAs per Riser DiagramVAV BoxWhtBlkARC15618-2CTypical of 324VacAs per Riser DiagramRedBlkARC15618-2CHWSHWRHCFLP312WhtBlkRedV-118-3CTT18-2CTypical For:G57G5913524VACREDBLK(3.1.3,C1)C-3REDBLK(3.1.3,B5)Supply Air TemperatureC-3TE-2Net+Net-+12VGndWHTBLKREDGRN(3.1.3,E4)C-4WHTBLKREDGRN(3.1.3,B5)Zone TempC-4S18-4CNote: Cable shields not shown on panel end.Exhaust Air from SpaceExhaust AirVAV Box EnclosureProvided by Box Mfr.MAC:1ZN341ACONTROLLERAir FlowBACnet®HighLowAO-1Reheat Valve, 0-10V21Gnd+ShieldNet-Net+123BACnetDataGnd21Act NetPwr3Zone Temp, RNETRn+GndRn-12+12V43RnetRnetIN-3, Th/DC2IN-4, Th/DC3IN-2, Th/DC34+GndALC-1BO-3Point Name 3, NO4BUS1++Gnd14LEDLStat PortIN-1Supply Air Temperature, Th/DC12+GndTherm/Dry0-5VIN-1IN-2Therm/Dry0-5VGnd24V ac21PowerBO-2Valve Close, NO3BO-1Valve Open, NO2WHTBLKRED(3.1.3,C2)C-2WHTBLKRED(3.1.3,B3)Reheat ValveC-2COM-1WHTBLKRED(3.1.3,D1)C-1WHTBLKRED(3.1.3,A3)Valve OpenC-1MAC:1ZASF-ACONTROLLERAir FlowBACnet®HighLowDataGnd21Act NetPwr3ALC-2Fin Tube RadiationHWSHWRFLP312WhtBlkRedV-218-3CMANUAL ON WARMER INFO COOLERAUTOMATED LOGICZS w/Motion SensorTag Part Number Product Description Manufacturer Panel/Field QuantityALC-1 ZN341A Zone Controller for VAV w/ Actuator, 3DO, 4UI, 1AO Automated Logic F 3ALC-2 ZASF-A VAV Airflow Sensor, Actuator, for Dual Duct Automated Logic F 3TE-2 ZS2P-M-ALC ZS2 Pro Space Temp & Motion, Rnet, LCD, SP Adj. Ovrd Automated Logic F 3TE-1 ALC/10K-2-D-8"-BB4 Duct, 8" Insertion, BAPI Box 4 IP44 BAPI F 3V-1 See Valve Schedule See Valve Schedule See Valve Schedule F 3V-2 See Valve Schedule See Valve Schedule See Valve Schedule 3Bill of Material 00000 DRAWING NAME:Equipment Rooms w/FCUPROJECT:18-060 Biotech ECI Pneumatic ReplacemntIthaca, NY 14850CONTRACT NO: 18-060REVDESCRIPTIONDATEBYFILENAME: 3.2 FCUsDE: RDHEquipment Rooms w/FCUSE:Bob Hilton829 Phillips RoadVictor, NY 14564ABCDEFGH1234512345PR: DRAWING NO.: 3.2.018-PWRDRAWING NO.: 3.2.0REDBLK(3.2.0,C2)C-103WHTBLKRED(3.2.0,C3)C-203REDBLK(3.2.0,C3)C-101REDBLK(3.2.0,C3)C-20524VACCOM-124VACMAC:1ZN253CONTROLLERAO-1FCU-1 CW Valve, 0-10V21Gnd+DO-1FCU-1 S/S, NO2BUS1DO-2FCU-2 S/S, NO3ShieldNet-Net+123CMnetGnd24V ac21, RNETRn+GndRn-12+12V43RnetGnd14LEDIN-4FCU-2 DAT, Th/DC2IN-5, Th/DC3LStat PortIN-1FCU-1 Current, 0-5V12+GndIN-2FCU-2 Current, 0-5V34+GndIN-3FCU-1 DAT, Th/DC56+GndALC-1AO-2FCU-2 CW Valve, 0-10V43Gnd+AO-3, 0-10V65Gnd+Therm/Dry0-5VIN-1Therm/Dry0-5VIN-224VACREDBLK(3.2.0,F3)C-102REDBLK(3.2.0,F3)C-204COM-1REDBLK(3.2.0,G2)C-104WHTBLKRED(3.2.0,G3)C-202See Riser Diagram for Address and Pwr assignmentsArcnet Com. Bus INAs per Riser DiagramArcnet Com. Bus OUTAs per Riser DiagramBlkWhtTypical of 11ENC-1Typical For:150234254308334350 1-FCU354428434450456 1-FCUTag Part Number Product Description Manufacturer Panel/Field QuantityCR-1 RIB2401C Enclosed Relay, 10A, SPDT, 24Vac/dc/120Vac Coil Functional Devices F 11CR-2 RIB2401C Enclosed Relay, 10A, SPDT, 24Vac/dc/120Vac Coil Functional Devices F 11IT-1 RIBXKTV5-10 0-10 Amp, 0-5VDC, Solid Core Functional Devices F 11IT-2 RIBXKTV5-10 0-10 Amp, 0-5VDC, Solid Core Functional Devices F 11ALC-1 ZN253 Zone Controller, 2DO, 5UI, 3AO Automated Logic P 11TE-1 ALC/10K-2-D-8"-BB4 Duct, 8" Insertion, BAPI Box 4 IP44 BAPI F 11TE-2 ALC/10K-2-D-8"-BB4 Duct, 8" Insertion, BAPI Box 4 IP44 BAPI F 11V-1 See Valve Schedule See Valve Schedule See Valve Schedule F 11V-2 See Valve Schedule See Valve Schedule See Valve Schedule F 11ENC-1 CSE992 9x9x2 Enclosure Versa Products Inc. F 11Bill of MaterialSupply AirReturn Air SFTTREDBLK(3.2.0,B4)FCU-2 CurrentC-102IT-1+-0-5V OutputWht/Yel24V120VCOMCNONCCR-1Wht/BlkWht/BluBluYelOrgRIBREDBLK(3.2.0,C5)FCU-2 S/SC-20418-4CREDBLK(3.2.0,B5)FCU-2 DATC-104WHTBLKRED(3.2.0,C4)FCU-2 CW ValveC-20218-3C18-2C18-2CREDBLK(3.2.0,B4)FCU-1 DATC-10318-4CIT-2+-0-5V Output18-3CWHTBLKRED(3.2.0,C4)FCU-1 CW ValveC-203TTWht/Yel24V120VCOMCNONCCR-2Wht/BlkWht/BluBluYelOrgRIBCCCHWSCHWRSupply AirReturn AirREDBLK(3.2.0,B4)FCU-1 CurrentC-101REDBLK(3.2.0,C5)FCU-1 S/SC-205 SFThese spaces have an existing VAV w/ALC controls and thermostatFC312WhtBlkRedV-1CCCHWSCHWRFO312WhtBlkRedV-2 00000 DRAWING NAME:Reheat Valves-1PROJECT:18-060 Biotech ECI Pneumatic ReplacemntIthaca, NY 14850CONTRACT NO: 18-060REVDESCRIPTIONDATEBYFILENAME: 7.1 Control Valve SchedulesDE: RDHReheat Valves-1SE:Bob Hilton829 Phillips RoadVictor, NY 14564ABCDEFGH1234512345PR: 1. Valve Types BL - Ball, BF - Butterfly, G - Globe, PI - Pressure Independent, SOL -SOLENOID, HT-HIGH TEMP2. Valve Patterns 2W - Two Way, 3W - Three Way Mixing, 3WD - Three Way Diverting 3. Actuator Types MO- Manual Override, SR - Spring Return, NSR - Non-Spring Return, SUTO - STEM UP TO OPEN, SUTC - STEM UP TO CLOSE 4. Fail-safe Positions NO/FO - Normally Open/Fail Open - Valve open A to AB, will close as voltage increases. Actuator switch on CW. Actuator will spring open upon power loss. NC/FC - Normally Closed/Fail Closed - Valve closes A to AB, will open as voltage increases. Actuator will spring closed upon power loss. NO/FC - Normally Open/Fail Closed - Valve open A to AB, will close as voltage increases. Actuator switch on CW. Actuator will spring closed upon power loss. NC/FO - Normally Closed/Fail Open - Valve closes A to AB, will open as voltage increases. Actuator will spring open upon power loss. FIP - Fail In Place - Non-fail safe actuator. 5. Control Signal Types 2 - Two Position, 3 - Three Wire (floating), 10 - 2 to 10 Vdc, 20 - 4 to 20 mA, MFT - Multi Function DRAWING NO.: 7.1.1Item No. Tag Qty.Line SizeValve SizeValve TypeValve PatternActuator TypeFail-Safe PositionControl Signal TypeActual Valve CvDesign Water Flow (GPM)Calculated Differential Pressure (psi) Body Rating (psig)Rated Close-off Manufacturer Valve Assembly Part Number1135 Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR US2139 Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR US3158 Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR US4159 Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR US5167 Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR US6207 Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR US7210 Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR US8212 Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR US9214 Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR US10216 Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR US11230 Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR US12230A Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR US13230B Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR US14235 Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR US15236 Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR US16239 Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR US17240 Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR US18258 Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR US19259 Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR US20265 Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR US21311 Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR US22312 Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR US23314 Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR US24326 Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR US25330 Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR US26330A Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR US27330B Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR US28335 Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR US29339 Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR US30352 Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR USAUTOMATIC VALVE SCHEDULE GENERAL VALVE INFORMATION WATER VALVEVALVE SIZING INFORMATION 00000 DRAWING NAME:Reheat Valves-2PROJECT:18-060 Biotech ECI Pneumatic ReplacemntIthaca, NY 14850CONTRACT NO: 18-060REVDESCRIPTIONDATEBYFILENAME: 7.1 Control Valve SchedulesDE: RDHReheat Valves-2SE:Bob Hilton829 Phillips RoadVictor, NY 14564ABCDEFGH1234512345PR: 1. Valve Types BL - Ball, BF - Butterfly, G - Globe, PI - Pressure Independent, SOL -SOLENOID, HT-HIGH TEMP2. Valve Patterns 2W - Two Way, 3W - Three Way Mixing, 3WD - Three Way Diverting 3. Actuator Types MO- Manual Override, SR - Spring Return, NSR - Non-Spring Return, SUTO - STEM UP TO OPEN, SUTC - STEM UP TO CLOSE 4. Fail-safe Positions NO/FO - Normally Open/Fail Open - Valve open A to AB, will close as voltage increases. Actuator switch on CW. Actuator will spring open upon power loss. NC/FC - Normally Closed/Fail Closed - Valve closes A to AB, will open as voltage increases. Actuator will spring closed upon power loss. NO/FC - Normally Open/Fail Closed - Valve open A to AB, will close as voltage increases. Actuator switch on CW. Actuator will spring closed upon power loss. NC/FO - Normally Closed/Fail Open - Valve closes A to AB, will open as voltage increases. Actuator will spring open upon power loss. FIP - Fail In Place - Non-fail safe actuator. 5. Control Signal Types 2 - Two Position, 3 - Three Wire (floating), 10 - 2 to 10 Vdc, 20 - 4 to 20 mA, MFT - Multi Function DRAWING NO.: 7.1.2Item No. Tag Qty.Line SizeValve SizeValve TypeValve PatternActuator TypeFail-Safe PositionControl Signal TypeActual Valve CvDesign Water Flow (GPM)Calculated Differential Pressure (psi) Body Rating (psig)Rated Close-off Manufacturer Valve Assembly Part Number31358 Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR US32359 Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR US33365 Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR US34369 Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR US35401 Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR US36406 Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR US37408 Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR US38412 Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR US39414 Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR US40416 Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR US41424 Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR US42430A Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR US43430B Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR US44435 Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR US45439 Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR US46458 Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR US47459 Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR US48465 Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR US49469 Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR US50470 Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR US51473 Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR US52G40 Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR US53G41 Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR US54G45 Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR US55G50 Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR US56G50B Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR US57G50C Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR US58G50D Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR US59G52 Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR USAUTOMATIC VALVE SCHEDULE VALVE SIZING INFORMATIONGENERAL VALVE INFORMATION WATER VALVE 00000 DRAWING NAME:Reheat Valves-3PROJECT:18-060 Biotech ECI Pneumatic ReplacemntIthaca, NY 14850CONTRACT NO: 18-060REVDESCRIPTIONDATEBYFILENAME: 7.1 Control Valve SchedulesDE: RDHReheat Valves-3SE:Bob Hilton829 Phillips RoadVictor, NY 14564ABCDEFGH1234512345PR: 1. Valve Types BL - Ball, BF - Butterfly, G - Globe, PI - Pressure Independent, SOL -SOLENOID, HT-HIGH TEMP2. Valve Patterns 2W - Two Way, 3W - Three Way Mixing, 3WD - Three Way Diverting 3. Actuator Types MO- Manual Override, SR - Spring Return, NSR - Non-Spring Return, SUTO - STEM UP TO OPEN, SUTC - STEM UP TO CLOSE 4. Fail-safe Positions NO/FO - Normally Open/Fail Open - Valve open A to AB, will close as voltage increases. Actuator switch on CW. Actuator will spring open upon power loss. NC/FC - Normally Closed/Fail Closed - Valve closes A to AB, will open as voltage increases. Actuator will spring closed upon power loss. NO/FC - Normally Open/Fail Closed - Valve open A to AB, will close as voltage increases. Actuator switch on CW. Actuator will spring closed upon power loss. NC/FO - Normally Closed/Fail Open - Valve closes A to AB, will open as voltage increases. Actuator will spring open upon power loss. FIP - Fail In Place - Non-fail safe actuator. 5. Control Signal Types 2 - Two Position, 3 - Three Wire (floating), 10 - 2 to 10 Vdc, 20 - 4 to 20 mA, MFT - Multi Function DRAWING NO.: 7.1.3Item No. Tag Qty.Line SizeValve SizeValve TypeValve PatternActuator TypeFail-Safe PositionControl Signal TypeActual Valve CvDesign Water Flow (GPM)Calculated Differential Pressure (psi) Body Rating (psig)Rated Close-off Manufacturer Valve Assembly Part Number61G54A Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR US62G57 Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR US63G59 Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR US64G63 Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR US65G65 Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR US66G67 Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR US67G68 Reheat 1 0.5 BL 2 NSR FIP 10 1.9 4.0 4.40 600 200 Belimo B211+TR24-SR USAUTOMATIC VALVE SCHEDULE VALVE SIZING INFORMATIONGENERAL VALVE INFORMATION WATER VALVE 00000 DRAWING NAME:FTR ValvesPROJECT:18-060 Biotech ECI Pneumatic ReplacemntIthaca, NY 14850CONTRACT NO: 18-060REVDESCRIPTIONDATEBYFILENAME: 7.1 Control Valve SchedulesDE: RDHFTR ValvesSE:Bob Hilton829 Phillips RoadVictor, NY 14564ABCDEFGH1234512345PR: 1. Valve Types BL - Ball, BF - Butterfly, G - Globe, PI - Pressure Independent, SOL -SOLENOID, HT-HIGH TEMP2. Valve Patterns 2W - Two Way, 3W - Three Way Mixing, 3WD - Three Way Diverting 3. Actuator Types MO- Manual Override, SR - Spring Return, NSR - Non-Spring Return, SUTO - STEM UP TO OPEN, SUTC - STEM UP TO CLOSE 4. Fail-safe Positions NO/FO - Normally Open/Fail Open - Valve open A to AB, will close as voltage increases. Actuator switch on CW. Actuator will spring open upon power loss. NC/FC - Normally Closed/Fail Closed - Valve closes A to AB, will open as voltage increases. Actuator will spring closed upon power loss. NO/FC - Normally Open/Fail Closed - Valve open A to AB, will close as voltage increases. Actuator switch on CW. Actuator will spring closed upon power loss. NC/FO - Normally Closed/Fail Open - Valve closes A to AB, will open as voltage increases. Actuator will spring open upon power loss. FIP - Fail In Place - Non-fail safe actuator. 5. Control Signal Types 2 - Two Position, 3 - Three Wire (floating), 10 - 2 to 10 Vdc, 20 - 4 to 20 mA, MFT - Multi Function DRAWING NO.: 7.1.4WATER VALVEItem No. Tag Qty.Line SizeValve SizeValve TypeValve PatternActuator TypeFail-Safe PositionControl Signal TypeActual Valve CvDesign Water Flow (GPM) Body Rating (psig)Rated Close-off Manufacturer Valve Assembly Part Number1135 FTR 1 0.5 BL 2 NSR FIP 10 1.9 4.0 600 200 Belimo B211+TR24-SR US2139 FTR 1 0.5 BL 2 NSR FIP 10 1.9 4.0 600 200 Belimo B211+TR24-SR US3158 FTR 1 0.5 BL 2 NSR FIP 10 1.9 4.0 600 200 Belimo B211+TR24-SR US4159 FTR 1 0.5 BL 2 NSR FIP 10 1.9 4.0 600 200 Belimo B211+TR24-SR US5167 FTR 1 0.5 BL 2 NSR FIP 10 1.9 4.0 600 200 Belimo B211+TR24-SR US6207 FTR 1 0.5 BL 2 NSR FIP 10 1.9 4.0 600 200 Belimo B211+TR24-SR US7216 FTR 1 0.5 BL 2 NSR FIP 10 1.9 4.0 600 200 Belimo B211+TR24-SR US8235 FTR 1 0.5 BL 2 NSR FIP 10 1.9 4.0 600 200 Belimo B211+TR24-SR US9239 FTR 1 0.5 BL 2 NSR FIP 10 1.9 4.0 600 200 Belimo B211+TR24-SR US10258 FTR 1 0.5 BL 2 NSR FIP 10 1.9 4.0 600 200 Belimo B211+TR24-SR US11259 FTR 1 0.5 BL 2 NSR FIP 10 1.9 4.0 600 200 Belimo B211+TR24-SR US12265 FTR 1 0.5 BL 2 NSR FIP 10 1.9 4.0 600 200 Belimo B211+TR24-SR US13335 FTR 1 0.5 BL 2 NSR FIP 10 1.9 4.0 600 200 Belimo B211+TR24-SR US14339 FTR 1 0.5 BL 2 NSR FIP 10 1.9 4.0 600 200 Belimo B211+TR24-SR US15358 FTR 1 0.5 BL 2 NSR FIP 10 1.9 4.0 600 200 Belimo B211+TR24-SR US16359 FTR 1 0.5 BL 2 NSR FIP 10 1.9 4.0 600 200 Belimo B211+TR24-SR US17365 FTR 1 0.5 BL 2 NSR FIP 10 1.9 4.0 600 200 Belimo B211+TR24-SR US18401 FTR 1 0.5 BL 2 NSR FIP 10 1.9 4.0 600 200 Belimo B211+TR24-SR US19416 FTR 1 0.5 BL 2 NSR FIP 10 1.9 4.0 600 200 Belimo B211+TR24-SR US20435 FTR 1 0.5 BL 2 NSR FIP 10 1.9 4.0 600 200 Belimo B211+TR24-SR US21439 FTR 1 0.5 BL 2 NSR FIP 10 1.9 4.0 600 200 Belimo B211+TR24-SR US22458 FTR 1 0.5 BL 2 NSR FIP 10 1.9 4.0 600 200 Belimo B211+TR24-SR US23459 FTR 1 0.5 BL 2 NSR FIP 10 1.9 4.0 600 200 Belimo B211+TR24-SR US24465 FTR 1 0.5 BL 2 NSR FIP 10 1.9 4.0 600 200 Belimo B211+TR24-SR US25G57 FTR 1 0.5 BL 2 NSR FIP 10 1.9 4.0 600 200 Belimo B211+TR24-SR US26G59 FTR 1 0.5 BL 2 NSR FIP 10 1.9 4.0 600 200 Belimo B211+TR24-SR USAUTOMATIC VALVE SCHEDULE GENERAL VALVE INFORMATIONVALVE SIZING INFORMATION 00000 DRAWING NAME:FCU CW ValvesPROJECT:18-060 Biotech ECI Pneumatic ReplacemntIthaca, NY 14850CONTRACT NO: 18-060REVDESCRIPTIONDATEBYFILENAME: 7.1 Control Valve SchedulesDE: RDHFCU CW ValvesSE:Bob Hilton829 Phillips RoadVictor, NY 14564ABCDEFGH1234512345PR: 1. Valve Types BL - Ball, BF - Butterfly, G - Globe, PI - Pressure Independent, SOL -SOLENOID, HT-HIGH TEMP2. Valve Patterns 2W - Two Way, 3W - Three Way Mixing, 3WD - Three Way Diverting 3. Actuator Types MO- Manual Override, SR - Spring Return, NSR - Non-Spring Return, SUTO - STEM UP TO OPEN, SUTC - STEM UP TO CLOSE 4. Fail-safe Positions NO/FO - Normally Open/Fail Open - Valve open A to AB, will close as voltage increases. Actuator switch on CW. Actuator will spring open upon power loss. NC/FC - Normally Closed/Fail Closed - Valve closes A to AB, will open as voltage increases. Actuator will spring closed upon power loss. NO/FC - Normally Open/Fail Closed - Valve open A to AB, will close as voltage increases. Actuator switch on CW. Actuator will spring closed upon power loss. NC/FO - Normally Closed/Fail Open - Valve closes A to AB, will open as voltage increases. Actuator will spring open upon power loss. FIP - Fail In Place - Non-fail safe actuator. 5. Control Signal Types 2 - Two Position, 3 - Three Wire (floating), 10 - 2 to 10 Vdc, 20 - 4 to 20 mA, MFT - Multi Function DRAWING NO.: 7.1.5Item No. Tag Qty.Line SizeValve SizeValve TypeValve PatternActuator TypeFail-Safe PositionControl Signal TypeActual Valve CvDesign Water Flow (GPM)Calculated Differential Pressure (psi) Body Rating (psig)Rated Close-off Manufacturer Valve Assembly Part Number1150 FCU CW 2 0.75 BL 2 SR NC/FC 10 4.7 10.0 4.50 600 200 Belimo B217+TFRX24-SR2234 FCU CW 2 0.75 BL 2 SR NC/FC 10 4.7 10.0 4.50 600 200 Belimo B217+TFRX24-SR3254 FCU CW 2 0.75 BL 2 SR NC/FC 10 4.7 10.0 4.50 600 200 Belimo B217+TFRX24-SR4308 FCU CW 2 0.75 BL 2 SR NC/FC 10 4.7 10.0 4.50 600 200 Belimo B217+TFRX24-SR5334 FCU CW 2 0.75 BL 2 SR NC/FC 10 4.7 10.0 4.50 600 200 Belimo B217+TFRX24-SR6350 FCU CW 1 0.75 BL 2 SR NC/FC 10 4.7 10.0 4.50 600 200 Belimo B217+TFRX24-SR7354 FCU CW 2 0.75 BL 2 SR NC/FC 10 4.7 10.0 4.50 600 200 Belimo B217+TFRX24-SR8428 FCU CW 2 0.75 BL 2 SR NC/FC 10 4.7 10.0 4.50 600 200 Belimo B217+TFRX24-SR9434 FCU CW 2 0.75 BL 2 SR NC/FC 10 4.7 10.0 4.50 600 200 Belimo B217+TFRX24-SR10450 FCU CW 2 0.75 BL 2 SR NC/FC 10 4.7 10.0 4.50 600 200 Belimo B217+TFRX24-SR11456 FCU CW 1 0.75 BL 2 SR NC/FC 10 4.7 10.0 4.50 600 200 Belimo B217+TFRX24-SRAUTOMATIC VALVE SCHEDULE GENERAL VALVE INFORMATION WATER VALVEVALVE SIZING INFORMATION DETAILS.1 DETAILS.2