HomeMy WebLinkAboutCornell TransportationH-000 JRM CEF SCHEDULES - HVAC SYMBOLS LIST, & GENERAL NOTES, GENERAL PIPING NOTES: GENERAL DUCTWORK NOTES: REPLACED BY THE CONTRACTOR. PIPING AS NECESSARY TO AVOID RIBS. ANY RIBS DAMAGED BY CONTRACTOR WILL NEED TO BE PIPE PENETRATIONS MUST FALL WITHIN CONCRETE BLOCKS, AVOID CONCRETE BEAM RIBS. OFFSET SLEEVE AND SEAL ALL WALL AND FLOOR PENETRATIONS. FIRESTOP ALL PENETRATIONS. CONSTRUCTION, OFF SITE IN PROPER LEGAL MANNER. CONTRACTOR SHALL DISPOSE OF ALL DEMOLITION AND/OR OTHER WASTE MATERIALS CAUSED BY WITH SHEETMETAL, EQUIPMENT AND ALL OTHER TRADES. AROUND DUCTWORK AND OTHER SERVICES. COORDINATE ALL WORK PRIOR TO CONSTRUCTION PIPING IS SHOWN SCHEMATICALLY. RUN PIPING WITHIN JOIST SPACING AND OFFSET AS REQUIRED COORDINATE ALL WORK WITH OTHER TRADES PRIOR TO CONSTRUCTION. CLEARANCES AND ENSURE NO OTHER SERVICES OR TRADES RUN THROUGH SERVICE AREA. MAINTAIN SERVICE CLEARANCES OF ALL EQUIPMENT. ADVISE OTHER TRADES OF SERVICE F. E. D. C. B. A. R. Q. P. O. N. M. L. K. J. I. H. G. F. E. D. C. B. A. RIBS DAMAGED BY CONTRACTOR WILL NEED TO BE REPLACED BY THE CONTRACTOR. DUCTWORK AS NECESSARY TO AVOID RIBS. DUCTWORK MAY NEED TO BE SPLIT AS REQUIRED. ANY DUCT PENETRATIONS MUST FALL WITHIN CONCRETE BLOCKS, AVOID CONCRETE BEAM RIBS. OFFSET ALL TRANSFER DUCTWORK TO BE LINED WITH ACOUSTIC THERMAL DUCT LINING. ALL DUCT DIMENSIONS SHOWN ON DRAWINGS ARE INSIDE DIMENSIONS. WITHIN CEILING GRIDS. REFER TO "A" SERIES DRAWINGS FOR EXACT LOCATIONS OF REGISTERS, GRILLES AND DIFFUSERS MAINTENANCE OR ADJUSTMENT ABOVE GYPSUM CEILINGS. DO NOT LOCATE VOLUME DAMPERS, VALVES OR ANY OTHER DEVICES REQUIRING VOLUME DAMPER HANDLE. LET RIBBON HANG ABOVE CEILING. PROVIDE 1" WIDE x 2’-0" LONG RED RIBBON AT EACH VOLUME DAMPER. TIE RIBBON TO WHEN FAN IS ENERGIZED, DAMPER OPENS FULLY. ALL AUTOMATIC AIR DAMPERS SHALL BE WIRED THROUGH MOTOR STARTER SUCH THAT WHERE DUCTS PASS ABOVE EACH OTHER, OFFSET AS REQUIRED INTO BEAM SPACE. FOR PIPING REQUIREMENTS REFER TO PIPING PLANS. MOUNT ALL SENSORS 48" ABOVE FINISHED FLOOR. OFF SITE IN A PROPER LEGAL MANNER. DISPOSE OF ALL DEMOLITION AND/OR OTHER WASTE MATERIALS CAUSED BY CONSTRUCTION ACCORDANCE WITH FIRE DAMPER DETAIL AND MANUFACTURER’S INSTRUCTIONS. PROVIDE FIRE DAMPER AT ALL LOCATIONS WITH "FD". INSTALL FIRE DAMPER IN STRICT THROUGH ACCESS AREA. MAINTAIN SERVICE CLEARANCES OF ALL EQUIPMENT. ENSURE NO OTHER SERVICES RUN DUCT. FLEXIBLE DUCT MAXIMUM LENGTH IS 48", AS PER THE SPECIFICATIONS. DIFFUSER CONNECTIONS TO BRANCH DUCT TO BE FULL NECK SIZE INSULATED FLEXIBLE TURNING VANES. TURNING VANES SHALL BE OMITTED FROM TRANSFER DUCT ELBOWS. ALL 90 DEGREE RECTANGULAR ELBOWS AND DUCTWORK TEES TO BE HARD MITRE WITH SHUT DOWN FEES. COORDINATE ALL SHUT DOWNS WITH OWNER PRIOR TO CONSTRUCTION. PAY ALL REQUIRED WITH OTHER SERVICES. COORDINATE EXACT LOCATION OF ALL DUCTWORK ROUTES, EQUIPMENT AND DEVICES ALL PENETRATIONS. SLEEVE AND SEAL ALL WALL AND FLOOR PENETRATIONS. PROVIDE FIRE STOPPING FOR DUCT CONTINUED DOUBLE LINE RECTANGULAR T T E PNEUMATIC/ELECTRIC THERMOSTAT AIR FLOW NTS NOT TO SCALE PIPE ANCHOR (DBL) PIPE GUIDE CFM CUBIC FEET PER MINUTE EXPANSION COMPENSATOR WITH GUIDES AD ACCESS DOOR PRE-FAB EXPANSION LOOP P.C.PLUMBING CONTRACTOR STRAINER N.O.NORMALLY OPEN PRESSURE GAUGE DSD DUCT SMOKE DETECTOR THERMOMETER H HUMIDISTAT UNION AIR VENTV ROUND DUCT - IN INCHES12" TT THERMOSTATIC TRAP SQUARE TO ROUND TRANSITION FT FLOAT & THERMOSTATIC TRAP UP OR DOWN RETURN DUCT TURNING 24x12 10x8 DN UP DN UP TD THERMODYNAMIC TRAP10"14" TEE CONICAL 8"18"ROUND BRANCH ROUND MAIN SUPPLY/RETURN BT BUCKET TRAP REGISTER OR GRILLE RETURN OR EXHAUST DIRECTION OF FLOW VOLUME DAMPER BBD BOILER BLOW DOWN CWS CHILLED WATER SUPPLY CWR CHILLED WATER RETURN D DRAIN FUEL OIL FILLFOF FUEL OIL GAUGEFOG FOS FUEL OIL SUPPLY FOR FUEL OIL RETURN FOV FUEL OIL TANK VENT G GAS GLYCOL SUPPLYGS GLYCOL RETURNGR HWS HOT WATER SUPPLY HWR HOT WATER RETURN HG HOT GAS LPS LOW PRESSURE STEAM LPC LOW PRESSURE CONDENSATE MPS MEDIUM PRESSURE STEAM MPC MEDIUM PRESSURE CONDENSATE HPS HIGH PRESSURE STEAM HPC HIGH PRESSURE CONDENSATE PC PUMPED CONDENSATE RD REFRIGERANT DISCHARGE RL REFRIGERANT LIQUID RS REFRIGERANT SUCTION VAC VACUUM CW DOMESTIC COLD WATER EXISTING WORK TO BE REMOVED SINGLE LINE PIPE OR DUCT CONTINUED ROUND DUCT CONTINUED DOUBLE LINE PIPE OR MBH THOUSAND BTU/HOUR (E)EXISTING FPM FEET PER MINUTE AFF ABOVE FINISHED FLOOR G.C.GENERAL CONTRACTOR E.C.ELECTRICAL CONTRACTOR N.C.NORMALLY CLOSED S TEMPERATURE SENSOR DUCT TAKEOFFSSINGLE LINE DOUBLE LINE UP OR DOWN SUPPLY DUCT TURNING 24x12 10x8 DN UPUPDN 10x88x6 24x1214x8 TAP 6" BOOT RECTANGULAR BRANCH RECTANGULAR MAIN SUPPLY/RETURN 10"14" 8"18"ROUND BRANCH ROUND MAIN SUPPLY/RETURN LATERAL SUPPLY DIFFUSER, REGISTER OR GRILLE FLEXIBLE DUCTWORK COMPRESSED AIRA CAP OR PLUG ELBOW DOWN ELBOW UP AAD AUTOMATIC AIR DAMPER FD FIRE DAMPER SD SMOKE DAMPER BDD BACK DRAFT DAMPER M MOTORIZED DAMPER BALL VALVE GATE VALVE CHECK VALVE BALANCING VALVE BUTTERFLY VALVE SAFETY RELIEF VALVE PRESSURE REDUCING VALVEPRV CONTROL VALVE PRESSURE/TEMPERATURE TEST PLUG HVAC SYMBOL LIST (L)ACOUSTIC THERMAL LINING - 1" THICK (2L)ACOUSTIC THERMAL LINING - 2" THICK M.C.MECHANICAL CONTRACTOR W/W WALL TO WALL T G S THERMOSTAT/SENSOR WITH GUARDG DUCT SECTION - SUPPLY DUCT SECTION - RETURN WIDTH A x DEPTH B A B R R DIRECTION OF AIRFLOW RISE IN DUCT - IN D D DIRECTION OF AIRFLOW DROP IN DUCT - IN 10x824x1214" TAP 6" BOOT ROUND BRANCH RECTANGULAR MAIN SUPPLY/RETURN8" BG BLAST GATE FIN TUBE RADIATION VALANCE A B C C = CFM B = NECK SIZE A = TYPE REGISTER, GRILLE OR DIFFUSER TAG A B C D D = HEATING GPM C = COOLING GPM B = COIL SIZE A = TYPE VALANCE TAG POINT OF CONNECTION POINT OF DISCONNECTION BOTTOM TAP TRIPLE DUTY VALVETD GLOBE VALVE THREE WAY CONTROL VALVE SUCTION DIFFUSERSD CAP AND CHAIN DRAIN VALVE WITH HOSE CONNECTION, FC FLEX CONNECTOR - DUCTWORK DESCRIPTIONSYMBOL DESCRIPTIONSYMBOL FLEXIBLE CONNECTOR - PIPING A B C C = MINIMUM CFM B = MAXIMUM CFM A = UNIT NO. AIR TERMINAL UNIT TAG (OPTION 2) FO AxB DUCT SECTION - FLAT OVAL (FO) V VENT WATER FLOW SENSOR VSD BASE MOUNTED PUMP IN LINE PUMP WELL PNEUMATIC ACTUATOR AVERAGING SENSOR VARIABLE SPEED DRIVE COOLING COIL C C PROBE SENSOR E ELECTRIC ACTUATOR AIR FLOW SENSOR FS A S F R P DO DI AI AO DIGITAL INPUT (GENERAL) DIGITAL OUTPUT (GENERAL) ANALOG INPUT (GENERAL) ANALOG OUTPUT (GENERAL) ALARM STATUS FLOW SWITCH RELAY PRESSURE SWITCH DIFFERENTIAL STATIC FZ EXHAUST AIR OUTSIDE AIR RETURN AIR SUPPLY AIR FREEZE-STAT EA OA RA SA (OPPOSED BLADE) AUTOMATIC AIR DAMPER HUMIDIFIER DISPERSIAN TUBE REGISTER OR GRILLE THREE WAY THROW SUPPLY DIFFUSER, REGISTER OR GRILLE TWO WAY THROW SUPPLY DIFFUSER, REGISTER OR GRILLE ONE WAY THROW SUPPLY DIFFUSER, E P PE CT C O S S D E H F P P I E I CURRENT TRANSDUCER START/STOP ENABLE/DISABLE ELECTRICAL INTERFACE H C HEATING COIL FILTER S TRANSDUCER ELECTRIC/PNEUMATIC TRANSDUCER ELECTRONIC/ELECTRIC OR RELAY ELECTRIC/PNEUMATIC SWITCH OR RELAY PNEUMATIC/ELECTRIC SWITCH PRESSURE TRANSMITTER (DUCT MOUNTED) HUMIDITY SENSOR FLOW TRANSMITTER G B GAS BURNER PRESSURE TRANSMITTER DIFFERENTIAL STATICP OPEN/CLOSE OR PIPE MOUNTED) TEMPERATURE SENSOR (DUCT (PARALLEL BLADE) AUTOMATIC AIR DAMPER M MAIN CONTROL AIR (TEMP. CONTROL) I ELECTRONIC INTERFACE H HUMIDIFIER ES END SWITCH SYMBOL DESCRIPTION SYMBOL DESCRIPTION FD/SD COMBINATION FIRE AND SMOKE DAMPER DOUBLE WALL LINED DUCT- 3" THICK MTHWS MEDIUM TEMPERATURE HOT WATER SUPPLY (COGEN) MTHWR MEDIUM TEMPERATURE HOT WATER RETURN (COGEN) CO2 CARBON DIOXIDE TRANSMITTER M FLOW METER OS OCCUPANCY SENSOR M MOISTURE SENSOR SW SOFTEN WATER HPWS HPWR HEAT PUMP WATER SUPPLY HEAT PUMP WATER RETURN TCS FAN COIL UNIT COOLING SUPPLY TCR FAN COIL UNIT COOLING RETURN THS FAN COIL UNIT HEATING SUPPLY THR FAN COIL UNIT HEATING RETURN SF RF EF SUPPLY AIR FAN RETURN AIR FAN EXHAUST AIR FAN CO CARBON MONOXIDE TRANSMITTER E E ELECTRONIC CONTROL VALVE (3-WAY) ELECTRONIC CONTROL VALVE (2-WAY) B C D D = GPM C = ENCLOSURE LENGTH B = FIN TUBE LENGTH FT-A = TYPE RADIANT CEILING PANEL TAG FIN TUBE RADIATION/ FT-A RADIANT CEILING PANEL PS TS TEMPERATURE SENSOR PRESSURE SENSOR A AIR TERMINAL UNIT AND TAG (OPTION 1) AIR TERMINAL UNIT X"LAB AIR VALVE FACTORY ATTENUATOR AIR TERMINAL UNIT WITH X" FACTORY SOUND ATTENUATOR LAB AIR VALVE WITH SERVICE CLEARANCE P PRESSURE SWITCH CO CARBON MONOXIDE DETECTOR CONDENSING UNIT WATER SUPPLYCS CR CONDENSING UNIT WATER RETURN FILTER BANK PS PUMP SPEED CO2 DIOXIDE SENSOR WALL MOUNTED CARBON FS FAN SPEED SW SPEED SWITCH WALL MOUNTED FAN COIL DS DRIVE SPEED SCHEDULE UNIT CONDITIONING AIR SYSTEM SPLITDUCTLESS NUMBERSYSTEM UNIT INDOOR LOCATION UNITINDOOR UNITOUTDOOR (SEER) EFFICIENCY MINIMUM No. MODEL &MANUFACTURER INDOOR OUTDOOR TYPEUNIT CFM (MBH) CAPACITY COOLING EAT VOLTS PHASE MCA (dBA) PRESSURE SOUND REFRIGERANT VOLTS PHASE MCA (AMPS) SIZE BREAKER EAT UNITINDOOR UNITOUTDOOR DB WB DB WB DSS-1 UNIT-1 MOUNTEDWALL 240 7.5 76 65 208 1 0.12 33 R410A 208 1 12.6 20 95.0 75.0 17.6 UNIT-2 MOUNTEDWALL 240 7.5 76 65 208 1 0.12 33 NOTES: 1. POWER. 208V/1PH WITH EQUAL OR "MINI-LIME" MODEL ASPEN AN BE SHALL PUMP CONDENSATETHE INDOOR UNITS ASSOCIATED WITH DSS-1 SYSTEMS SHALL BE PROVIDED WITH A FACTORY PACKAGED CONDENSTE PUMP. CTOC 110 CTOC 110 110 MAPLE 110 MAPLE PANASONIC CS-MKS7NKU PANASONIC CS-MKS7NKU PANASONIC CU-3KS19NBU SCHEDULE DIFFUSER AND GRILLEREGISTER TYPE APPLICATION MATERIAL FINISH No. MODEL &MANUFACTURER REMARKS 1 SUPPLY STEEL WHITE OMNI MODELTITUS A RETURN/EXHAUST STEEL WHITE 355-RL MODELTITUS REHEAT WATER HOT - SCHEDULE UNIT TERMINAL AIR - DUCT SINGLE -VAV NO.UNIT SERVICE (CFM) FLOW AIR MAX (CFM) FLOW AIRMIN WC)(In. CFMMAX ATPRESS INLETMIN (In.) SIZE INLET S.P. 1"AT N.C.RAD S.P. 1"AT N.C.DISCH COILREHEAT FLUID No. MODEL &MANUFACTURER REMARKS (MBH) CAPACITY SIDEAIR SIDEWATER (CFM)FLOW AIRHEATING F)(DEG. TEMP AIRENT. F)(DEG. TEMP AIRLVG. WC)(In‘. P.D.AIR (GPM) FLOWWATER WC)(In. P.D.WATER F) (DEG.TEMP WATERENT. F) (DEG.TEMP WATERLVG. DEEP ROWS SAV-1 173 171, 170,OFFICE 870 270 1.0 9 20 19 11.1 270 55 93 0.15 0.9 0.09 180 155.2 1 WATER DESVTITUS 1 SAV-2 CORRIDOR 300 100 1.0 6 20 16 5.2 100 55 102.8 0.07 0.6 0.18 180 162.6 1 WATER DESVTITUS 1 SAV-3 165 167, 169,OFFICE 1560 485 1.0 12 24 21 18.4 485 55 90 0.23 1.5 0.31 180 154.8 1 WATER DESVTITUS 1 SAV-4 172 166, 162A,OFFICE 450 210 1.0 6 24 21 8 210 55 90 0.15 1 0.5 180 163.9 1 WATER DESVTITUS 1 SAV-5 162SECURITY 700 300 1.0 8 23 21 11.4 300 55 90 0.19 1.5 1.43 180 164.5 1 WATER DESVTITUS 1 SAV-6 OFFICEOPEN 1600 655 1.0 12 24 22 24.9 655 55 90 0.24 4.5 2.55 180 168.5 1 WATER DESVTITUS 1 SAV-7 OFFICEOPEN 1600 655 1.0 12 24 22 24.9 655 55 90 0.24 4.5 2.55 180 168.5 1 WATER DESVTITUS 1 SAV-8 161 RMSECURE 150 60 1.0 5 14 15 3.9 60 55 115.5 0.02 0.6 0.18 180 166.7 1 WATER DESVTITUS 1 SAV-9 164 MEETINGSMALL 465 140 1.0 6 25 22 6.1 140 55 95.1 0.16 0.6 0.18 180 159.5 1 WATER DESVTITUS 1 SAV-10 168 AREAPROJ.360 120 1.0 6 22 18 5.7 120 55 98.5 0.1 0.6 0.18 180 161 1 WATER DESVTITUS 1 REMARKS: 1. ATTENUATOR SOUND FACTORYPROVIDE SCHEDULEFAN NO.UNIT LOCATION SERVICE CHARACTERISTICSFAN CHARACTERISTICSMOTOR No. MODEL &MANUFACTURER REMARKS TYPE CFM WC)(In. S.P. BHP MAX. RPM FAN SPEED TIPMAX. (FPM) VELOCITY OUTLETMAX. SONES DRIVE RPM HP VOLTS HZ PHASE STARTER 60 EF-1 STORAGE MAPLE110 110A CENT.INLINE 75 - -594 1186 382 .2 DIRECT 1100 W52.7 115 60 1 - GC-144 MODELCOOK 60 SCALE: NONE PLAN VIEW ELEVATION VIEW GRILLE FACE EXHAUST RETURN/ FACE GRILLE EXHAUST RETURN/ NECK GRILLE EXHAUST RETURN/ NECK SIZE EXHAUST GRILLE SAME SIZE AS RETURN/ SHEETMETAL PLENUM NECK SIZE EXHAUST GRILLE SAME SIZE AS RETURN/ SHEETMETAL PLENUM TOP OF PLENUM FROM GRILLE FACE TO 12" MINIMUM DIMENSION RETURN/ EXHAUST GRILLE PLENUM DETAIL NON-DUCTED SOUND LINING 1" THICK INTERNAL 1’-0" MIN. B. A. DETAIL NOTES: ALSO APPLICABLE TO REGISTERS INTERNAL SOUND LINING IS NOT SPECIFIED PAINT INSIDE OF PLENUM BOX FLAT BLACK IF DRAWINGS ARCHITECTURAL INDICATED ON CEILING TYPE AS 1 H000 ALL RIGHTS RESERVED ' ENGINEERING & LANDSCAPE ARCHITECTURE, P.C.. SPECIFIC WRITTEN PERMISSION OF SWBR ARCHITECTURE, CORPORATION FOR ANY PURPOSE WHATSOEVER EXCEPT WITH THE THEREOF SHALL BE UTILIZED BY ANY PERSON, FIRM, OR ENGINEERING & LANDSCAPE ARCHITECTURE, P.C. AND NO PART OWNED BY AND REMAIN THE PROPERTY OF SWBR ARCHITECTURE, AND PLANS INDICATED THEREON OR PRESENTED THEREBY ARE THESE DOCUMENTS AND ALL THE IDEAS, ARRANGEMENTS, DESIGNS 387 East Main Street Rochester, NY 14604-2107 Voice: 585.232.8300 Fax: 585.232.9221 w w w . s w b r . c o m FILE PATH:ROCHESTER, N E W Y O R K CONSULTANT PROJECT: CLIENT: DRAWING TITLE proj. no. checked proj. mgr. drawn by STATUS: DRAWING NO. ISSUE DATE:3/26/2014 9:49:24 AMC:\1-Local Revit Models 2014\13465.00_120Maple RTU Replacement_Central_kristins.rvtCORNELL UNIVERSITY REVISIONS no.date by description ENGINEERING P.C. MECHANICAL/ELECTRICAL ENGINEERING CONSULTANTS ROCHESTER, NEW YORK 14604 (585) 288-5590 FAX: (585) 288-0233 M/E Project 130267 150 NORTH CHESTNUT STREET ROCHESTER BUFFALO SYRACUSE CAPITAL DISTRICT JAD 13465.00 CIT RENOVATIONS 06/27/2014 DOCUMENTS 100% CONSTRUCTION NORTH 0SCALE: 1/4"=1’-0"2’4’8’ (E)10x10 GS/R UP (E)2" CH-1 HEATER (E)CABINET UP (E)10x10 GS/R (E)2" GS/R DN (E)2" GS/R UP (E)" 1 HD-100 NAIC JRM CEF (E)6x6 (E)RHC (E)12x8(E)10x8(E)VAV-2(E)8x8(E)12x10 (E)12x8(E)VAV-3 (E)10x8 (E)10x8(E)16x8(E)24x10 (E)8" (E)8"(E)8" (E)36x16 (E)28x16(E)28x14(E)24x10 (E)16x8 (E)50x14(E)36x18(E)UH-1 T T T T T TT DEMOLITION FIRST FLOOR - HVAC 120 MAPLE - PARTIAL 120 MAPLE - PARTIAL FIRST FLOOR PLAN - HVAC DEMOLITION HD100DSDDSD(E)30x16(E)36x26 (E)FD/SD(E)FD/SDDSD UP (E)" (E)1" (E)1" FIN TUBE (E)1" UP TO GROUND FLOOR " DN TO CONVECTOR ON (E)1" GS/R DN TO FIN TUBE TUBE (E)FIN (E)2" GS/R (E)2" GS/R (E)" GS/R (E)1" TO FIN TUBE (E)GS/R UP (E)6" DN EXHAUST UP (E)9x9 DISCHARGE PIPE (E)6" RELIEF VALVE x16 (E)38 (E)36x26 UP ALARM POINTS TO (E)FAN (E)EXHAUST FAN AND DISABLE DISCONNECT AND LOCKOUT BT DEMOLITION NOTES: 1 1 1 1 1 1 2 3 4 4 4 4 5 5 4 3 2 1 4 4 BACK TO WITHIN CONFERENCE ROOM. REMOVE EXISTING EXAUST GRILLE AND REMOVE DUCTWORK REMOVE EXISTING TEMPERATURE SENSOR. REMOVE EXISTING CABINET UNIT HEATER. REMOVE PIPING AND ACCESSORIES SHOWN CROSSHATCHED. REMOVE DUCTWORK AND ACCESSORIES SHOWN CROSSHATCHED. (E)24x12 (E)20x10 132 WOMEN 100TC STAIR 100SE VEST 100CB STAIR 100SD BREAK ROOM 133 LOBBY 100LA CORRIDOR 100CC ROOM CONFERENCE 156 ROOM CONFERENCE 130 ELEV 100EA VEST 100CE ALL RIGHTS RESERVED ' ENGINEERING & LANDSCAPE ARCHITECTURE, P.C.. SPECIFIC WRITTEN PERMISSION OF SWBR ARCHITECTURE, CORPORATION FOR ANY PURPOSE WHATSOEVER EXCEPT WITH THE THEREOF SHALL BE UTILIZED BY ANY PERSON, FIRM, OR ENGINEERING & LANDSCAPE ARCHITECTURE, P.C. AND NO PART OWNED BY AND REMAIN THE PROPERTY OF SWBR ARCHITECTURE, AND PLANS INDICATED THEREON OR PRESENTED THEREBY ARE THESE DOCUMENTS AND ALL THE IDEAS, ARRANGEMENTS, DESIGNS 387 East Main Street Rochester, NY 14604-2107 Voice: 585.232.8300 Fax: 585.232.9221 w w w . s w b r . c o m FILE PATH:ROCHESTER, N E W Y O R K CONSULTANT PROJECT: CLIENT: DRAWING TITLE proj. no. checked proj. mgr. drawn by STATUS: DRAWING NO. ISSUE DATE:3/26/2014 9:49:24 AMC:\1-Local Revit Models 2014\13465.00_120Maple RTU Replacement_Central_kristins.rvtCORNELL UNIVERSITY REVISIONS no.date by description ENGINEERING P.C. MECHANICAL/ELECTRICAL ENGINEERING CONSULTANTS ROCHESTER, NEW YORK 14604 (585) 288-5590 FAX: (585) 288-0233 M/E Project 130267 150 NORTH CHESTNUT STREET ROCHESTER BUFFALO SYRACUSE CAPITAL DISTRICT JAD 13465.00 CIT RENOVATIONS 06/27/2014 DOCUMENTS 100% CONSTRUCTION H-100 JRM CEF 110 MAPLE NORTH 0SCALE: 1/4"=1’-0"2’4’8’ 1 H100 CONDENSING UNIT DSS-1 SYSTEM 1 2 DRAWING NOTES: TUBE (E)FIN TUBE (E)FIN TUBE (E)FIN TUBE (E)FIN TUBE (E)FIN INDOOR UNIT-1 DSS-1 SYSTEM INDOOR UNIT-2 DSS-1 SYSTEM 3 3 EF-1 ELF375DX LOUVER 12x18 RUSKIN HVAC NEW WORK FIRST FLOOR PLAN - 110 MAPLE - PARTIAL 110 MAPLE - PARTIAL FIRST FLOOR PLAN - HVAC NEW WORK BY END SWITCH BEFORE FAN CAN START. WIRE AAD IN LINE WITH MOTOR STARTER. DAMPER MUST BE PROVEN OPEN PROVIDE TRANSITION AS REQUIRED TO CONNECT TO LOUVER. HANDLERS. SHALL BE AN "ASPEN MINI LIME" PUMP FOR USE IN DUCTLESS SPLIT SYSTEM AIR INDOOR DSS UNIT SHALL HAVE AN INTEGRAL CONDENSATE PUMP. CONDENSATE PUMP 5 4 3 2 1 4 5 TO (E) FLOOR DRAIN RUN DRAIN PIPING 1" I.W. " SUCTION " LIQUID " SUCTION " LIQUID 1" I.W. PITCH DN PITCH DN 6"APPROXIMATELY 2" IN DIAMETER. BUNDLE WITH PVC FITTINGS AT THE ELBOW LOCATIONS. EACH BUNDLE SHOULD BE BE TIE WRAPPED TOGETHER IN ONE BUNDLE. PROVIDE 30 MIL PVC PIPE WRAP AROUND SUCTION PIPE, LIQUID PIPE AND ELECTRICAL CONDUIT TO EACH INDOOR UNIT SHOULD WITH CONDENSING UNIT. WALL MOUNT CONDENSING UNIT. WALL MOUNTING BRACKET TO BE PROVIDED REF.STORAGE 110A CTOC 110 OFFICE 106 OFFICE 107 OFFICE 109 BREAK 105 OFFICE 104 OFFICE 104A OFFICE 102 OFFICE 101 CONFERENCE ROOM BREAK 113A OFFICE 108 TOILET 100TA MECH 100UA COPY ROOM 113 SERVER 111 CORR 3 TOILET 100TB CORRIDOR 100CA ALL RIGHTS RESERVED ' ENGINEERING & LANDSCAPE ARCHITECTURE, P.C.. SPECIFIC WRITTEN PERMISSION OF SWBR ARCHITECTURE, CORPORATION FOR ANY PURPOSE WHATSOEVER EXCEPT WITH THE THEREOF SHALL BE UTILIZED BY ANY PERSON, FIRM, OR ENGINEERING & LANDSCAPE ARCHITECTURE, P.C. AND NO PART OWNED BY AND REMAIN THE PROPERTY OF SWBR ARCHITECTURE, AND PLANS INDICATED THEREON OR PRESENTED THEREBY ARE THESE DOCUMENTS AND ALL THE IDEAS, ARRANGEMENTS, DESIGNS 387 East Main Street Rochester, NY 14604-2107 Voice: 585.232.8300 Fax: 585.232.9221 w w w . s w b r . c o m FILE PATH:ROCHESTER, N E W Y O R K CONSULTANT PROJECT: CLIENT: DRAWING TITLE proj. no. checked proj. mgr. drawn by STATUS: DRAWING NO. ISSUE DATE:3/26/2014 9:49:24 AMC:\1-Local Revit Models 2014\13465.00_120Maple RTU Replacement_Central_kristins.rvtCORNELL UNIVERSITY REVISIONS no.date by description ENGINEERING P.C. MECHANICAL/ELECTRICAL ENGINEERING CONSULTANTS ROCHESTER, NEW YORK 14604 (585) 288-5590 FAX: (585) 288-0233 M/E Project 130267 150 NORTH CHESTNUT STREET ROCHESTER BUFFALO SYRACUSE CAPITAL DISTRICT JAD 13465.00 CIT RENOVATIONS 06/27/2014 DOCUMENTS 100% CONSTRUCTION H-101 JRM CEF NORTH 0SCALE: 1/4"=1’-0"2’4’8’ 1 H10130x1630x12 8"8"8"8" 24x12 12" 12x10 8"8"14x10 14x10 12"38x16 20x1240x12 12" 12x6 22x1232x10 22x12 14x12 10" 8"8"22x12 10"10"10"10"10"10"12"SAV-10SAV-1 SAV-2 SAV-3SAV-4 SAV-5 SAV-6 SAV-7SAV-8SAV-9 S S S S S S S S S S 1 10" 300 1 10" 300 TYP=5 1 10" 320 TYP=5 1 10" 320 1 8" 150 1 8" 150 1 8" 150 1 8" 150 120 MAPLE HVAC NEW WORK FIRST FLOOR PLAN - 120 MAPLE - PARTIAL 120 MAPLE - PARTIAL FIRST FLOOR PLAN - HVAC NEW WORK10"10"10"1 10" 330 1 10" 270 1 10" 270 TYP=2 1 8" 200 TYP=2 1 8" 205 1 10" 370 1 10" 380 20x1214x1210"14x1010" 8" 8"8" 8" 1 12" 465 10" 10" 12"10"TYP=4 1 8" 175 14x10 14x12 8"8"8"8"8"8" TYP=4 1 8" 90 10"12x10S 40x1850x18 A 8x6 150 8"20x12 10" 8" A 8x6 150 10"A 12x10 36020x8 DRAWING NOTES: 1 (TYP.) TRANSFER 12x8 LINED TRANSFER 14x10 LINED TRANSFER 12x8 LINED TRANSFER 12x8 LINED TRANSFER 12x10 LINED TRANSFER 14x10 LINED TRANSFER 14x10 LINED 1 A 22x22 270 A 22x22 330 A 22x22 380 A 22x22 810 A 22x22 370 A 22x22 465 A 22x22 150 2 A 22x22 270 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3 3 3 CAP AND SEAL EXISTING EXHAUST DUCTWORK. PROVIDE NEW VAV BOX WITH FACTORY SOUND ATTENUATOR. DETAIL ON DRAWING H-000. PROVIDE LINED PLENUM FOR EXHAUST GRILLE. REFER TO WELDED WIRE MESH ON OPEN ENDED DUCTWORK PROVIDE ANGLE IRON FRAME WITH 1/2" x 1/2" 4 3 2 1 4 132 WOMEN 100TC ROOM SMALL MEETING 160B STAIR 100SE VEST 100CB STAIR 100SD OFFICE 160C ON-CALL ROOM 160A OPEN OFFICE 160 BREAK ROOM 133 LOBBY 100LA CORRIDOR 100CC ROOM CONFERENCE 156 ROOM CONFERENCE 130 OFFICE 175 OFFICE 173 ROOM CONFERENCE DIRECTOR’S 171 OFFICE 172 OFFICE 166 PROJECT AREA 168 QUIET AREA 167 OFFICE 169 OFFICE 165 ELECTRICAL 100UB CORR 100CG CORRIDOR 100CH ELEV 100EA VEST 100CE ALL RIGHTS RESERVED ' ENGINEERING & LANDSCAPE ARCHITECTURE, P.C.. SPECIFIC WRITTEN PERMISSION OF SWBR ARCHITECTURE, CORPORATION FOR ANY PURPOSE WHATSOEVER EXCEPT WITH THE THEREOF SHALL BE UTILIZED BY ANY PERSON, FIRM, OR ENGINEERING & LANDSCAPE ARCHITECTURE, P.C. AND NO PART OWNED BY AND REMAIN THE PROPERTY OF SWBR ARCHITECTURE, AND PLANS INDICATED THEREON OR PRESENTED THEREBY ARE THESE DOCUMENTS AND ALL THE IDEAS, ARRANGEMENTS, DESIGNS 387 East Main Street Rochester, NY 14604-2107 Voice: 585.232.8300 Fax: 585.232.9221 w w w . s w b r . c o m FILE PATH:ROCHESTER, N E W Y O R K CONSULTANT PROJECT: CLIENT: DRAWING TITLE proj. no. checked proj. mgr. drawn by STATUS: DRAWING NO. ISSUE DATE:3/26/2014 9:49:24 AMC:\1-Local Revit Models 2014\13465.00_120Maple RTU Replacement_Central_kristins.rvtCORNELL UNIVERSITY REVISIONS no.date by description ENGINEERING P.C. MECHANICAL/ELECTRICAL ENGINEERING CONSULTANTS ROCHESTER, NEW YORK 14604 (585) 288-5590 FAX: (585) 288-0233 M/E Project 130267 150 NORTH CHESTNUT STREET ROCHESTER BUFFALO SYRACUSE CAPITAL DISTRICT JAD 13465.00 CIT RENOVATIONS 06/27/2014 DOCUMENTS 100% CONSTRUCTION (E)10x10 UP (E)10x10 DSDDSD(E)30x16(E)36x26 (E)FD/SD(E)FD/SDDSD x16 (E)38 (E)36x26 UP H-102 JRM CEF NORTH 0SCALE: 1/4"=1’-0"2’4’8’ 1 H102SAV-10SAV-1 SAV-2 SAV-3SAV-4 SAV-6 SAV-5 SAV-8SAV-7 SAV-9 120 MAPLE PIPING FIRST FLOOR PLAN - 120 MAPLE - PARTIAL 120 MAPLE - PARTIAL FIRST FLOOR PLAN - PIPING & HWR 1" HWS & HWR 1" HWS & HWR 1" HWS & HWR 3/4" HWS & HWR 1" HWS & HWR 3/4" HWS & HWR " HWS & HWR " HWS & HWR " HWS & HWR " HWS & HWR " HWS & HWR " HWS & HWR " HWS DRAWING NOTES: CAP AND SEAL EXISTING PIPING.1 1 1 1 132 WOMEN 100TC ROOM SMALL MEETING 160B STAIR 100SE VEST 100CB STAIR 100SD OFFICE 160C ON-CALL ROOM 160A OPEN OFFICE 160 BREAK ROOM 133 LOBBY 100LA CORRIDOR 100CC ROOM CONFERENCE 156 ROOM CONFERENCE 130 OFFICE 175 OFFICE 173 ROOM CONFERENCE DIRECTOR’S 171 OFFICE 172 OFFICE 166 PROJECT AREA 168 QUIET AREA 167 OFFICE 169 OFFICE 165 ELECTRICAL 100UB CORR 100CG CORRIDOR 100CH ELEV 100EA VEST 100CE ALL RIGHTS RESERVED ' ENGINEERING & LANDSCAPE ARCHITECTURE, P.C.. SPECIFIC WRITTEN PERMISSION OF SWBR ARCHITECTURE, CORPORATION FOR ANY PURPOSE WHATSOEVER EXCEPT WITH THE THEREOF SHALL BE UTILIZED BY ANY PERSON, FIRM, OR ENGINEERING & LANDSCAPE ARCHITECTURE, P.C. AND NO PART OWNED BY AND REMAIN THE PROPERTY OF SWBR ARCHITECTURE, AND PLANS INDICATED THEREON OR PRESENTED THEREBY ARE THESE DOCUMENTS AND ALL THE IDEAS, ARRANGEMENTS, DESIGNS 387 East Main Street Rochester, NY 14604-2107 Voice: 585.232.8300 Fax: 585.232.9221 w w w . s w b r . c o m FILE PATH:ROCHESTER, N E W Y O R K CONSULTANT PROJECT: CLIENT: DRAWING TITLE proj. no. checked proj. mgr. drawn by STATUS: DRAWING NO. ISSUE DATE:3/26/2014 9:49:24 AMC:\1-Local Revit Models 2014\13465.00_120Maple RTU Replacement_Central_kristins.rvtCORNELL UNIVERSITY REVISIONS no.date by description ENGINEERING P.C. MECHANICAL/ELECTRICAL ENGINEERING CONSULTANTS ROCHESTER, NEW YORK 14604 (585) 288-5590 FAX: (585) 288-0233 M/E Project 130267 150 NORTH CHESTNUT STREET ROCHESTER BUFFALO SYRACUSE CAPITAL DISTRICT JAD 13465.00 CIT RENOVATIONS 06/27/2014 DOCUMENTS 100% CONSTRUCTION GS/R UP (E)2" CH-1 HEATER (E)CABINET GS/R (E)2" GS/R DN (E)2" GS/R UP (E)" UP (E)" (E)1" (E)1" FIN TUBE (E)1" UP TO GROUND FLOOR " DN TO CONVECTOR ON (E)1" GS/R DN TO FIN TUBE TUBE (E)FIN (E)2" GS/R (E)2" GS/R (E)" GS/R (E)1" TO FIN TUBE (E)GS/R UP BT H-103 JRM CEF CCC NORTH 0SCALE: 1/4"=1’-0"2’4’8’ 2 H-103 FLOOR PLAN - HVAC CCC - PARTIAL FIRST NORTH 0SCALE: 1/4"=1’-0"2’4’8’ 1 H-103 PARTIAL FIRST FLOOR PLAN - HVAC DEMOLITION PARTIAL FIRST FLOOR PLAN - HVAC NEW WORK DEMOLITION NOTES: SHALL MEASURE EXISTING AIRFLOW PRIOR TO REMOVAL. REMOVE EXISTING SUPPLY DIFFUSER. BALANCING CONTRACTOR SHALL MEASURE EXISTING AIRFLOW PRIOR TO REMOVAL. REMOVE EXISTING RETURN GRILLE. BALANCING CONTRACTOR 2 1 1 1 2 2 DRAWING NOTES: 1 1 22 TYP=2 A 48x12 - GENERAL NOTES: INSTALL INTO NEW CEILING GRID. EXISTING SPRINKLER HEADS TO REMAIN IN CURRENT LOCATIONS.A. TYP=2 1 10" - NEW DIFFUSER. PROVIDE DUCTWORK AND TRANSITION AS REQUIRED TO CONNECT TO PROVIDE NEW SUPPLY AIR DIFFUSER. BALANCE TO EXISTING AIRFLOW. NEW GRILLE. PROVIDE DUCTWORK AND TRANSITION AS REQUIRED TO CONNECT TO PROVIDE NEW RETURN AIR GRILLE. BALANCE TO EXISTING AIRFLOW. 2 1 ALL RIGHTS RESERVED ' ENGINEERING & LANDSCAPE ARCHITECTURE, P.C.. SPECIFIC WRITTEN PERMISSION OF SWBR ARCHITECTURE, CORPORATION FOR ANY PURPOSE WHATSOEVER EXCEPT WITH THE THEREOF SHALL BE UTILIZED BY ANY PERSON, FIRM, OR ENGINEERING & LANDSCAPE ARCHITECTURE, P.C. AND NO PART OWNED BY AND REMAIN THE PROPERTY OF SWBR ARCHITECTURE, AND PLANS INDICATED THEREON OR PRESENTED THEREBY ARE THESE DOCUMENTS AND ALL THE IDEAS, ARRANGEMENTS, DESIGNS 387 East Main Street Rochester, NY 14604-2107 Voice: 585.232.8300 Fax: 585.232.9221 w w w . s w b r . c o m FILE PATH:ROCHESTER, N E W Y O R K CONSULTANT PROJECT: CLIENT: DRAWING TITLE proj. no. checked proj. mgr. drawn by STATUS: DRAWING NO. ISSUE DATE:3/26/2014 9:49:24 AMC:\1-Local Revit Models 2014\13465.00_120Maple RTU Replacement_Central_kristins.rvtCORNELL UNIVERSITY REVISIONS no.date by description ENGINEERING P.C. MECHANICAL/ELECTRICAL ENGINEERING CONSULTANTS ROCHESTER, NEW YORK 14604 (585) 288-5590 FAX: (585) 288-0233 M/E Project 130267 150 NORTH CHESTNUT STREET ROCHESTER BUFFALO SYRACUSE CAPITAL DISTRICT JAD 13465.00 CIT RENOVATIONS 06/27/2014 DOCUMENTS 100% CONSTRUCTION FEC FEC FECC STORAGE - 121 STOR. - A STOR. - B WORK AREA OFFICE 119A OFFICE BATTERY ROOM 103 EC 10062 VIDEO EDITING 125MEN 10020 CLOSET WOMEN 10021 CORRIDOR 10042CORRIDOR 10040 CORR 10041 CORRIDOR 10046 CORRIDOR 10060 STAIR 10001 STAIR 10002 10044 TC 10064 PROGRAM SPACE TECHNOLOGY ACADEMIC 123 FEC FEC FECOFFICE BATTERY ROOM 103 119A EC 10062 VIDEO EDITING 125MEN 10020 CLOSET WOMEN 10021 CORRIDOR 10042CORRIDOR 10040 CORR 10041 CORRIDOR 10046 CORRIDOR 10060 STAIR 10001 STAIR 10002 10044 10064 CEF H-500 JRM DI OSEE AIR SUPPLY AO F.L. AI T MOD AO COM OR BACnet / MSTP: BACnet / ARCNET - AV: FLOW SETPOINT (CFM) - AV: POSITION FEEDBACK (%) - AV: FLOW FEEDBACK (CFM) AI Tsa d SETPOINT AV H C H C 2 H-500 SCALE: NO SCALE TYPICAL REHEAT- W/ VAV - SCHEDULEPOINT EQUIPMENT POINTS HARDWARE POINTSSOFTWARE GRAPHIC ONSHOW NOTES AV BV SCH TREND ALARM DI DO AI AO BACS EMCS DESCRIPTION COMMAND POSITION DAMPER BOX VAVSUPPLY X X X (CFM) FEEDBACK AIRFLOW BOX VAVSUPPLY X X X SETPOINT FROM DEVIATION FLOW10%X POINT NETWORK MSTPBACnet (CFM) SETPOINT AIRFLOW BOX VAVSUPPLY X X X POINT NETWORK MSTPBACnet (%) FEEDBACK POSITION BOX VAVSUPPLY X X X FEEDBACK TO EQUAL NOT COMMANDVALVE X POINT NETWORK MSTPBACnet COMMAND POSITION VALVE COILREHEAT X X X CLOSED COMMANDED VALVE WITH COIL ACROSS T DELTAF o 5 X LASTFAIL TEMPERATURE AIR LEAVING COILREHEAT X X X SENSOR POINTSINGLE TYPICAL SENSORS- SPACE - SCHEDULEPOINT SETPOINT TEMPERATURESPACE X X X TEMPERATURESPACE X X X OCCUPANCYSPACE X X X X VAV SUPPLY - OPERATION OFSEQUENCE GENERAL - 1PART DESCRIPTIONSYSTEM1.1 coil reheat water hot with box VAV airSupplyA. GENERAL1.2 (BACS). system control and automation building the through controlled be shallSystemA. adjustable. be shall setpointsAllB. hours. ten least at forpower of loss a during setting time and programming its retaining of capable be shall BACSTheC. SETPOINTS1.3 Setpoints: Temperature CoolingSpaceA. F deg. 75Occupied:1. F deg. 78 Setback:Occupied2. F deg. 81Unoccupied:3. Setpoints: Temperature HeatingSpaceB. F deg. 70Occupied:1. F deg. 67 Setback:Occupied2. F deg. 64Unoccupied:3. minutes 30 Time: Index OccupancyMinimumC. Mon-Fri PM, 8 TO AM 6 Schedule: OccupancyZoneD. CONTROL TEMPERATUREZONE1.4 sensors. occupancy spaceand schedule programmed of combination a on based determined be shall setpointsTemperatureA. coil.reheat with box VAV supply a by served space each for typical is This closed. be shall valvecontrol coil reheat setpoint, at is temperature space the When setpoint. temperature spacethe maintain to modulate shall valve control reheat the setpoint, temperature heatingoccupied the below falls temperature space the and period occupied scheduled the duringoccupied is space the If mode. heating in airflow minimum at be shall box VAV Heating:OccupiedB. setpoint. temperaturecooling space the maintain to required as open modulate shall damper box VAV supply thesetpoint, cooling occupied the above rises temperature space the If F. deg 70 of temperaturespace a above closed commanded be shall valve control coil reheat VAV The Cooling:OccupiedC. setpoints. temperature setback occupied theat maintained be shall space the but apply, shall sequences heating/cooling occupied abovethe period, occupied scheduled the during unoccupied becomes space the If Setback:OccupiedD. setpoint. maintain torequired as modulate shall valve control coil reheat the setpoint, temperature heatingunoccupied the below falls temperature space the and period unoccupied scheduled theduring unoccupied is space the If airflow minimum its at be shall box VAV The Heating:UnoccupiedE. F. deg70 above is space the when closed be shall valve control coil reheat The setpoint.temperature cooling space the maintain to required as open modulate shall damper box VAV supplythe setpoint, cooling unoccupied the above rises temperature space the If Cooling:UnoccupiedF. mode. unoccupied to back index shall space the period, unoccupied scheduled the duringagain unoccupied becomes space the When occupancy. of duration the for mode occupied toindex shall space the period, unoccupied scheduled the during occupied becomes space theIfG. BACS. the at indicatedbe shall alarm failure coil heating a F, deg 80 above is box VAV the from temperaturedischarge the and position closed fully its to commanded been has coil reheat box VAV ventilation theIfH. MATRIX SHED LOADSTEAM POINTCONTROL STEAM SHED-1LOAD STEAM SHED-2LOAD STEAM SHED-3LOAD STEAM SHED-4LOAD STEAM SHED-5LOAD STEAM SHED-6LOAD CONTROLZONE SPACESNON-RESEARCH MODE UNOCCUPIED TO SPACEINDEX F DEG 60 TO POINT SET TEMPERATUREINDEX SPACESRESEARCH MODE OCCUPIED TO RESETTABLE MODE, UNOCCUPIED TO SPACEINDEX F DEG 60 TO POINT SET TEMPERATURE SPACEAND AC/PH UNPCCUPIED MIN TO RATE CHANGE AIR SPACEINDEX (2) SPACESCRITICAL CONTROLUNDER SPACESRESIDENTIAL CONTROLUNDER F DEG 65 TO POINTSET TEMPERATURE SPACEINDEX CONTROL SYSTEM HANDLINGAIR HALLWAY / ATRIUM - SYSTEMS FAN AIRMIXED CONTROLUNDER RECIRCULATION 100% TOINDEX "OFF" UNITINDEX OFFICE/CLASSROOM/AUDITORIUM - SYSTEMS FAN AIRMIXED CONTROLUNDER POSITION MIN TO DAMPER AIR OUTDOORINDEX RECIRCULATION 100% TOINDEX "OFF" UNITINDEX (2) CRITICAL - SYSTEMS FAN AIRMIXED CONTROLUNDER CRITICAL NON - SYSTEMS AIR OUTSIDE100% CONTROLUNDER F DEG 55 TOTEMPERATURE AIR DISCHARGEINDEX "OFF" UNITINDEX (2) CRITICAL - SYSTEMS AIR OUTSIDE100% CONTROLUNDER (1) F DEG 55 TO TEMPERATURE AIR DISCHARGEINDEX SYSTEMS AIR MAKE-UPLABORATORY CONTROLUNDER (1) F DEG 55 TO TEMPERATURE AIR DISCHARGEINDEX SYSTEMS EXHAUSTLABORATORY CONTROLUNDER SYSTEMS EXHAUSTGENERAL CONTROLUNDER "OFF"INDEX CONTROL SYSTEMHYDRONIC CRITICAL NON - SYSTEM LOOPREHEAT CONTROLUNDER LOWERIS WHICHEVER SCHEDULE,RESET MAINTAIN OR F DEG140 TO TEMPERATURE LOOPINDEX "ON" PUMPS VALVE, STEAMCLOSE (2) CRITICAL - SYSTEMS LOOPREHEAT CONTROLUNDER SYSTEM LOOPPERIMETERHEATING CONTROLUNDER LOWER IS WHICHEVER SCHEDULE, RESET MAINTAIN OR F DEG 140 TO TEMPERATURE LOOPINDEX SYSTEM LOOP HEATINGGLYCOL CONTROLUNDER SYSTEM LOOP HEATINGRADIANT CONTROLUNDER 1 H-500 SCALE: NO SCALE TYPICAL SUPPLY VAV BOX CONTROL DIAGRAM HVAC & LOAD SHED - CONTROL DIAGRAM STEAM LOAD SHED DRAWINGS FOR LOCATIONS BY DIV. 26. REFER TO ELECTRICAL OCCUPANCY SENSORS PROVIDED ALL RIGHTS RESERVED ' ENGINEERING & LANDSCAPE ARCHITECTURE, P.C.. SPECIFIC WRITTEN PERMISSION OF SWBR ARCHITECTURE, CORPORATION FOR ANY PURPOSE WHATSOEVER EXCEPT WITH THE THEREOF SHALL BE UTILIZED BY ANY PERSON, FIRM, OR ENGINEERING & LANDSCAPE ARCHITECTURE, P.C. AND NO PART OWNED BY AND REMAIN THE PROPERTY OF SWBR ARCHITECTURE, AND PLANS INDICATED THEREON OR PRESENTED THEREBY ARE THESE DOCUMENTS AND ALL THE IDEAS, ARRANGEMENTS, DESIGNS 387 East Main Street Rochester, NY 14604-2107 Voice: 585.232.8300 Fax: 585.232.9221 w w w . s w b r . c o m FILE PATH:ROCHESTER, N E W Y O R K CONSULTANT PROJECT: CLIENT: DRAWING TITLE proj. no. checked proj. mgr. drawn by STATUS: DRAWING NO. ISSUE DATE:3/26/2014 9:49:24 AMC:\1-Local Revit Models 2014\13465.00_120Maple RTU Replacement_Central_kristins.rvtCORNELL UNIVERSITY REVISIONS no.date by description ENGINEERING P.C. MECHANICAL/ELECTRICAL ENGINEERING CONSULTANTS ROCHESTER, NEW YORK 14604 (585) 288-5590 FAX: (585) 288-0233 M/E Project 130267 150 NORTH CHESTNUT STREET ROCHESTER BUFFALO SYRACUSE CAPITAL DISTRICT JAD 13465.00 CIT RENOVATIONS 06/27/2014 DOCUMENTS 100% CONSTRUCTION ,DASHED LIGHT IS EXISTING TO BE REMOVED. EXISTING ELECTRICAL OR EQUIPMENT OR DEVICE, ,RELOCATED. EXISTING TO REMAIN OR EXISTING TO BE EXISTING WIRING OR EQUIPMENT, SOLID LIGHT IS HEAVY SOLID IS NEW, SYMBOL DESCRIPTION GENERAL CONSTRUCTION SYMBOLS EXISTING DEVICE TO REMAIN(E) EXISTING DEVICE TO BE RELOCATED (ER) PANELBOARD ONE LINE DIAGRAM SYMBOLS SYMBOL DESCRIPTION NON-FUSED DISCONNECT SWITCH CIRCUIT BREAKER THERMAL MAGNETIC MOLDED CASE T AND TYPE AND TRANSFORMER SCHEDULE FOR SIZE TRANSFORMER, REFER TO ONE LINE DIAGRAM SYMBOL DESCRIPTION FIRE ALARM MANUAL PULL STATIONF WIRE GUARD SMOKE DETECTOR SUBSCRIPT "WG" INDICATES S RATE OF RISE HEAT DETECTOR H VISUAL SIGNAL DEVICEF TS TAMPER SWITCH SPRINKLER WATERFLOW SWITCHWF FIRE ALARM CONTROL PANELFACP FIRE ALARM ANNUNCIATION PANELFAAP REMOTE DUCT SMOKE DETECTOR TEST STATIONRTS FSD FAN SHUT DOWN SPEAKER/STROBE ALARM SIGNALF INDIVIDUAL ADDRESSABLE MODULEIAM FIRE ALARM TRANSPONDER NODEFATN SYMBOL DESCRIPTION LUMINAIRES SWITCHING DESIGNATION. SCHEDULE, LOWER CASE LETTER INDICATES LETTERS INDICATE FIXTURE TYPE ON CEILING MOUNTED LUMINAIRE. UPPER CASE SWITCHING DESIGNATION. SCHEDULE, LOWER CASE LETTER INDICATES LETTERS INDICATE FIXTURE TYPE ON WALL MOUNTED LUMINAIRE. UPPER CASE NL CEILING MOUNTED EXIT LUMINAIRE WALL MOUNTED EXIT LUMINAIRE FA d FA d ’NL’ DENOTES UNSWITCHED LUMINAIRE CONNECTED TO EMERGENCY CIRCUIT SYMBOL DESCRIPTION BASIC MATERIALS AND METHODS ELECTRICAL SYMBOLS LIST J JUNCTION BOX COMPLETE CONNECTION TO EQUIPMENT LP-404 FOR RACEWAY TYPE. TO MATCH HOMERUN. REFER TO SPEC’S BRANCH CIRCUIT WIRING SIZE AND NUMBER EG., IN " C, UNLESS NOTED OTHERWISE. SHALL BE 20 AMP, 120 VOLT, 2-#12, 1-#12 EQUALS NUMBER OF CIRCUITS. CIRCUIT INDICATE CIRCUITS. NUMBER OF ARROWS NUMBERS INDICATE PANEL. NUMBERS HOME RUN TO PANELBOARD. LETTERS/ X - MATCH EQUIPMENT CAP T - TWISTLOCK SUBSCRIPT INDICATES TYPE: PROVIDE CORD AND CAP. EQUIPMENT BEING FURNISHED BY OTHERS. BRANCH CIRCUIT AND/OR MATCH CAP ON AND NEMA CONFIGURATION AS REQUIRED BY PROPER VOLTAGE, CLASS, CURRENT RATING SPECIAL PURPOSE RECEPTACLE. PROVIDE SWITCHES LETTERS EQUALS NO. OF GANGED a,b,c - SWITCHING DESIGNATIONS NUMBER OF OS - OCCUPANCY SENSOR 3 - THREE WAY SWITCH INDICATE TYPE: ON FIXTURE SCHEDULE, SUBSCRIPTS TOGGLE SWITCH, VOLTAGE AS INDICATED 3 a,b,c UC - UNDER THE COUNTER GFI - GROUND FAULT INTERUPT WP - WEATHER PROOF OC - OVER COUNTER SUBSCRIPTS INDICATE TYPE: DUPLEX RECEPTACLE, 20 AMP, 125 VOLT OS UNLESS NOTED OTHERWISE. CIRCUIT TO SINGLE POLE CIRCUIT BREAKER(S), SOLID HALF ARROW(S) INDICATES 120 VOLT UNLESS NOTED OTHERWISE. CIRCUIT TO MULTI-POLE CIRCUIT BREAKER, SOLID FULL ARROW INDICATES 208 VOLT UNLESS NOTED OTHERWISE. CIRCUIT TO SINGLE POLE CIRCUIT BREAKER(S), OPEN HALF ARROW(S) INDICATES 277 VOLT UNLESS NOTED OTHERWISE. CIRCUIT TO MULTI-POLE CIRCUIT BREAKER, OPEN FULL ARROW INDICATES 480 VOLT ABOVE. DDC ALARM WIRING BY DIV 15A. PROVIDE"C STUBBED TO CEILING SPACE SINGLE GANG BOX WITH BLANK COVER PLATE. DDC SURFACE RACEWAY WITH DEVICES AS INDICATED COMBINATION POWER AND COMMUNICATION POWER RACEWAY WITH DEVICES AS INDICATED INTELLIGENT MONITOR MODULEIMM S IMM INTELLIGENT MONITORING MODULE SMOKE DETECTOR WITH "IMM" INDICATES DUCT SMOKE DETECTORDSD SCHEDULE ON ELECTRIC EQUIPMENT AND CONTROL MAGNETIC STARTER AMP RATING AS INDICATED COMBINATION FUSED DISCONNECT SWITCH AND SYMBOL DESCRIPTION AND CONTROL POWER DISTRIBUTION EQUIPMENT AND CONTROL SCHEDULE FOR SIZE. MOTOR CONNECTION. REFER TO ELECTRIC M AND CONTROL SCHEDULE INDICATED ON ELECTRIC EQUIPMENT DISCONNECT SWITCH AMP RATING AS VARIABLE FREQUENCY DRIVEVFD 208/120 VOLT PANELBOARD 480 VOLT PANELBOARD SMOKE DAMPER GENERAL DEMOLITION NOTES: GENERAL NOTES: P. O. N. M. L. K. J. I. H. G. F. E. D. C. B. A. EQUIPMENT WILL OPERATE PROPERLY. AFTER RENOVATING EXISTING ELECTRICAL WORK, THE CONTRACTOR SHALL INSURE THAT ALL REMAINING AND NEW OUTSIDE OF THE SCOPE OF WORK. OF DEMOLITION, CONTRACTOR SHALL FIELD VERIFY ALL BRANCH CIRCUITS AND MAINTAIN THOSE CIRCUITS THAT EXTEND DISCONNECT AND REMOVE PANEL, FEEDERS AND BRANCH CIRCUITS BACK TO POINT OF SOURCE PRIOR TO THE START BUT ARE AFFECTED BY THE DEMOLITION OR NEW CONSTRUCTION. WALLS AND CEILINGS. MAINTAIN THE CONTINUITY OF BRANCH CIRCUIT WIRING TO ANY AREAS WHICH ARE TO REMAIN COMPLETELY BACK TO THE PANELBOARD. THE CONTRACTOR SHALL NOT ABANDON BRANCH CIRCUIT WIRING IN EXISTING BRANCH CIRCUIT WIRING TO DEVICES IN AREAS OF DEMOLITION SHALL BE DISCONNECTED, MADE SAFE AND REMOVED DISCONNECT, MAKE SAFE AND REMOVE ALL TEMPORARY AND ABANDONED WIRE WITHIN THE SPACE. PROPERTY OF THE CONTRACTOR AND SHALL BE REMOVED FROM THE SITE. INDICATED TO BE REMOVED UNLESS OTHERWISE INDICATED. ALL ITEMS REJECTED BY THE OWNER SHALL BECOME THE OF ITEMS TO BE RETAINED. TURN OVER TO OWNER THE EXISTING ZONED "FACP" AND EXISTING FIRE ALARM DEVICES INVENTORY MAJOR ELECTRICAL ITEMS THAT ARE REMOVED AND PROVIDE A LIST TO THE OWNER FOR THEIR SELECTION IN ACCORDANCE WITH THE PLANS AND/OR AS DIRECTED AFTER COMPLETION OF OTHER TRADE’S WORK IN THAT AREA. AND STORE ANY OR ALL ELECTRICAL ITEMS IN PATH OF WORK, REINSTALLING AND RECONNECTING SAME AS REQUIRED, IN ANY AREA REQUIRING THE PERFORMANCE OF ANY TRADE’S WORK, THIS CONTRACTOR SHALL CAREFULLY REMOVE TO BE REUSED, SHALL BE CUT OFF FLUSH WITH SLAB LEVEL WITH CONCRETE. ALL EXISTING CONDUITS STUBBED THROUGH FLOOR SERVING ITEMS TO BE REMOVED AND NOT SHOWN OR REQUIRED AND FEEDERS PASSING THROUGH AND SERVING UNDISTURBED AREAS (SHOWN OR NOT SHOWN). MAINTAIN AND RESTORE, IF INTERRUPTED BY REMOVALS OR IN PATH OF NEW CONSTRUCTION, ALL CIRCUITS, CONDUITS DEMOLITION. SAFE ANY EQUIPMENT TO BE REMOVED BY OTHERS. COORDINATE REMOVAL OF EQUIPMENT WITH OTHER TRADES PRIOR TO SHALL BE REUSED AS DETERMINED BY CONTRACTOR. ALL UNUSED CONDUITS SHALL BE REMOVED. DISCONNECT AND MAKE DRAWINGS SHALL BE DISCONNECTED AND REMOVED UNLESS NOTED OTHERWISE. WALLBOXES, BACKBOXES AND CONDUIT FEEDERS AND CONDUITS BACK TO POINT OF SOURCE UNLESS OTHERWISE NOTED. ALL ITEMS SHOWN ON THE DEMOLITION THE EXISTING ELECTRICAL EQUIPMENT AND DEVICES WITHIN DEMOLITION AREA SHALL BE DEMOLISHED ALONG WITH ALL OTHER PERIODS. APPROVAL TO BE IN WRITING. DISCRETION OF THE FIRE DEPARTMENT AND THE OWNER’S REPRESENTATIVE, BUT MUST BE PLACED BACK ON LINE DURING RENOVATION MAY BE DISCONNECTED FROM SERVICE DURING THE HOURS THE CONTRACTOR IS WORKING, AT THE EXISTING FIRE ALARM SYSTEM SHALL BE KEPT OPERATIONAL DURING THE CONSTRUCTION PERIOD THE BUILDING UNDER THE ELECTRICAL CONTRACTOR. EQUIPMENT BEING ABANDONED OR REMOVED, WHICH WILL REQUIRE DE-ENERGIZATION, REMOVAL AND BLANK-OFF BY REFER TO PLUMBING CONTRACT DRAWINGS AND SPECIFICATIONS FOR EXACT QUANTITIES AND LOCATIONS OF ALL PLUMBING NOT ALL DEVICES TERMINATIONS, JUNCTION BOXES AND WIRING HAVE BEEN SHOWN. WORK. PARTICULAR CARE SHALL BE TAKEN TO AVOID CREATING HAZARD OR CAUSING DISRUPTION IN ADJOINING AREAS. AND CAP ALL SERVICE LINES TO BE DISCONNECTED FOR THOSE SERVICES WHICH NORMALLY ARE INCLUDED IN HIS FIELD OF CONTRACTOR SHALL PARTICIPATE IN SURVEY OF THE EXISTING ELECTRICAL SYSTEMS. THE CONTRACTOR SHALL DISCONNECT UNFAMILIARITY WITH SITE CONDITIONS THAT ARE VISIBLE OR READILY CONSTRUED BY EXPERIENCED OBSERVERS. THIS THAT WILL AFFECT THE DEMOLITION WORK. NO COMPENSATION WILL BE GRANTED FOR ADDITIONAL WORK CAUSED BY AND ARE NOT GUARANTEED. PRIOR TO SUBMITTING BID, VISIT SITE AND IDENTIFY EXISTING CONDITIONS AND DIFFICULTIES EXISTING CONDITIONS ARE TAKEN FROM FIELD OBSERVATIONS AND PRIOR CONSTRUCTION DOCUMENTS WHEN AVAILABLE COORDINATE ALL SHUTDOWNS WITH UNIVERSITY PRIOR TO DEMOLITION. COORDINATE PHASING OF WORK WITH OWNER’S REPRESENTATIVE. NEW WORK. PROTECT BUILDING AND FURNISHINGS FROM DAMAGE. THE CONTRACTOR IS RESPONSIBLE FOR THE REMOVAL AND REPLACEMENT OF EXISTING CONSTRUCTION IN THE WAY OF AS POSSIBLE, SUBJECT TO THE OWNERS APPROVAL. OF THE CONTRACTOR’S WORK, IT SHALL BE REPAIRED AND/OR REPLACED WITH SIMILAR OR LIKE MATERIALS, AS MUCH WHEN EXISTING CONSTRUCTION, WHICH IS TO REMAIN, IS DAMAGED DURING THE COURSE OF DEMOLITION AS A RESULT MOUNTING HEIGHT & MISC. INFO. 1 DESIGNATION PANEL TYPICAL FOR ALL DEVICES AND HOMERUNS GFI NUMBER INDICATES CIRCUIT NUMBER NUMBER CIRCUIT IDENTIFICATION BRANCH CIRCUITING SWITCH LEG FIXTURE TYPE a B NUMBER INDICATES CIRCUIT2 NOTE: 1 NLGP-B PANELBOARD AND GEAR LEGEND CIRCUIT BREAKER GROUND FAULT INTERRUPTING MLO MAIN LUG ONLY MICRO AFF CB GFI MCB EG EQUIPMENT GROUND FCU FAN COIL UNIT AFG AWG AMERICAN WIRE GAGE ABOVE FINISHED GRADE ABBREVIATIONS UOI OFCI WP TSP UC OC TWISTED SHIELDED PAIR UNLESS OTHERWISE INDICATED OWNER FURNISHED, CONTRACTOR INSTALLED CLG.CEILING A.AMPERE EXIST.EXISTING MAIN CIRCUIT BREAKER GND. KW. GROUND KILOWATT ABBREV. C. HP. CONDUIT ABOVE FINISHED FLOOR PH.PHASE PNL.PANEL REFRIG. TYP. SP.SPACE POLE SW. 4 W.WIRE 3P.15A. ABBREV. P. PP REFRIGERATOR POWER PANEL SWITCH TYPICAL WEATHERPROOF MOUNTED UNDER COUNTER HEIGHT MOUNTED OVER COUNTER HEIGHT P = POLE A = AMPERE DESCRIPTION NIC NOT IN CONTRACT LS LIFE SAFETY BRANCH CR EQ CRITICAL BRANCH EQUIPMENT BRANCH HORSEPOWER MICROWAVE DESCRIPTION VOLTV. VAV VARIABLE AIR VOLUME K. J. I. H. G. F. E. D. C. B. A. TMGB TELECOMMUNICATIONS MAIN GROUND BAR BMGB BUILDING MAIN GROUND BAR PROVIDE PULLBOX FOR EVERY 180 OF BENDS FOR TEL/DATA AND 360 OF BENDS FOR POWER CONDUITS. ALL CONDUITS AND SUPPORTS SHALL BE AS TIGHT TO DECK AS POSSIBLE. NEW YORK STATE, BUILDING CODE OF NEW YORK STATE AND CORNELL UNIVERSITY DESIGN STANDARDS. ALL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF NFPA CODES, FIRE CODE OF TO CIRCUIT(S) AS INDICATED. PROVIDE CONDUIT/WIRING (CIRCUITING) AND REQUIRED EQUIPMENT CONNECTIONS TO ALL DEVICES/EQUIPMENT. CONNECT SEPARATE NEUTRALS (CIRCUITS SHALL NOT SHARE NEUTRALS). SAME EQUIPMENT GROUND) FOR EACH 20 AMPERE CIRCUIT UNLESS OTHERWISE NOTED. ALL CIRCUITS SHALL HAVE CIRCUITING TO DEVICES/EQUIPMENT SHALL BE 2-#12AWG & 1-#12EG (MULTIPLE HOME RUNS IN SAME CONDUIT MAY SHARE AND NOT GREATER THAN 96 INCHES ABOVE THE FINISHED FLOOR. FIRE ALARM SIGNALING APPLIANCES SHALL BE MOUNTED SUCH THAT THE ENTIRE LENS IS NOT LESS THAN 80 INCHES PROVIDE NYLON PULLSTRING IN ALL EMPTY CONDUITS. MINIMUM CONDUIT SIZE SHALL BE " FOR POWER CIRCUITS UOI. TO CONSTRUCTION. COORDINATE EXACT LOCATION OF ALL CONDUIT ROUTES, EQUIPMENT AND DEVICES WITH EXISTING CONDITIONS PRIOR MAINTAIN SERVICE CLEARANCES OF ALL EQUIPMENT. NON RATED PENETRATIONS. ALL FIRE RATINGS SHALL BE MAINTAINED. UTILIZE REMOVABLE FIRESTOPPING MATERIAL AT CABLE TRAY PENETRATIONS. PROVIDE ACOUSTICAL SEALANT FOR ALL SLEEVE AND SEAL ALL WALL AND FLOOR PENETRATIONS. PROVIDE FIRESTOPPING FOR ALL FIRE-RATED PENETRATIONS. U - ULTRASONIC SUBSCRIPTS INDICATE TYPE: (DUAL TECHNOLOGY WITH 360 VIEW) CEILING MOUNTED OCCUPANCY SENSOR 9" C/T W FACEPLATE AND BDF. CAT 6 UTP CABLE, TERMINATE IN OTHERWISE NOTED). PROVIDE ONE(1) NEAREST CABLE TRAY (UNLESS BOX. 1" EMT CONDUIT EXTENDED TO WAP - WALL MOUNT AT 90"AFF 4"x2"x 1-3/4" BDF. 46"AFF. PROVIDE (1) CAT 6 CABLE TO FOR DATA/VOICE. WALL MOUNT AT CABLE TRAY (UNLESS OTHERWISE NOTED) AND 1" CONDUIT EXTENDED TO NEAREST W - SINGLE GANG BACK BOX WITH MUD RING TERMINATE AT PATCH PANEL IN BDF. CONDUIT BUSHING. PULL (3) CAT 6 CABLES TERMINATE CONDUIT AT CABLE TRAY WITH (UNLESS OTHERWISE NOTED) FOR DATA/VOICE. EXTENDED TO NEAREST CABLE TRAY OR BDF FACEPLATE WITH TRIPLEX DESIGN. 1" CONDUIT 4"x4"x2.5D" BOX WITH A 2-GANG MUD RING & ON DRAWINGS CABLE TRAY: SIZE AS CALLED FOR IF MORE THAN ONE) QUANTITY (ONLY LP - 208Y/120 VOLT HP - 480Y/277 VOLT G- GROUND 1- FIRST 2- SECOND 3- THIRD 4- FOURTH 5- FIFTH FAR FIRE ALARM RELEASE RELAY SD DH DOOR HOLD OPEN E-000 MRG MRG LIST & GENERAL NOTES ELECTRICAL SYMBOL HP-GA WITH BATTERY PACK WALL MOUNTED EMERGENCY LUMINAIRE EXISTING TEL/DATA DROP SOURCES. CONNECTION POINT AT POWER AND DATA PROVIDE WITH SURFACE RACEWAY TO WALL/ DUPLEX RECEPTACLES AND TWO DATA BOXES. WIREMOLD OFR 4 GANG DEVICE BOX WITH TWO ALL RIGHTS RESERVED ' ENGINEERING & LANDSCAPE ARCHITECTURE, P.C.. SPECIFIC WRITTEN PERMISSION OF SWBR ARCHITECTURE, CORPORATION FOR ANY PURPOSE WHATSOEVER EXCEPT WITH THE THEREOF SHALL BE UTILIZED BY ANY PERSON, FIRM, OR ENGINEERING & LANDSCAPE ARCHITECTURE, P.C. AND NO PART OWNED BY AND REMAIN THE PROPERTY OF SWBR ARCHITECTURE, AND PLANS INDICATED THEREON OR PRESENTED THEREBY ARE THESE DOCUMENTS AND ALL THE IDEAS, ARRANGEMENTS, DESIGNS 387 East Main Street Rochester, NY 14604-2107 Voice: 585.232.8300 Fax: 585.232.9221 w w w . s w b r . c o m FILE PATH:ROCHESTER, N E W Y O R K CONSULTANT PROJECT: CLIENT: DRAWING TITLE proj. no. checked proj. mgr. drawn by STATUS: DRAWING NO. ISSUE DATE:3/26/2014 9:49:24 AMC:\1-Local Revit Models 2014\13465.00_120Maple RTU Replacement_Central_kristins.rvtCORNELL UNIVERSITY REVISIONS no.date by description ENGINEERING P.C. MECHANICAL/ELECTRICAL ENGINEERING CONSULTANTS ROCHESTER, NEW YORK 14604 (585) 288-5590 FAX: (585) 288-0233 M/E Project 130267 150 NORTH CHESTNUT STREET ROCHESTER BUFFALO SYRACUSE CAPITAL DISTRICT JAD 13465.00 CIT RENOVATIONS 06/27/2014 DOCUMENTS 100% CONSTRUCTION ED-100 MRG MRG 110 MAPLE 1 WAP S F S DEMOLITION NOTES: 1 (E) (E) S (E) (E) (E) (E) (E) (E) (E) (E) (E)(E) (E) (E) (E)FACPDOOR ACCESS PANEL MDP1 PP2 PP1 PP4 F F (E) (E) NORTH 0SCALE: 1/4"=1’-0"2’4’8’ 1 PARTIAL FIRST FLOOR PLAN - ELECTRICAL DEMOLITION (E) ELECTRICAL DEMOLTION FIRST FLOOR PLAN - 110 MAPLE -PARTIAL ED-100 F (E) (E) (E) (E) EXISTING DATA SWITCH AND CABLING TO BE REMOVED. TURN OVER ELECTRONICS TO OWNER. A. GENERAL NOTES: ALL CIRCUITS NOT REUSED SHALL BE REMOVED BACK TO SOURCE. SALVAGE EXISTING LIGHTING AND POWER CIRCUITS FOR REUSE AND EXTENSION. REF.STORAGE 110A STORAGE 110 CORR 3 CORRIDOR 100CA MECH 100UA TOILET 100TA TOILET 100TB SERVER 111 COPY ROOM 113 BREAK 113A CONFERENCE ROOM VEST 100CB OFFICE 102 OFFICE 104A OFFICE 104 OFFICE 106 SPRINKLER 100UB OFFICE 107 MECH 100UC OFFICE 109 OFFICE 108 ALL RIGHTS RESERVED ' ENGINEERING & LANDSCAPE ARCHITECTURE, P.C.. SPECIFIC WRITTEN PERMISSION OF SWBR ARCHITECTURE, CORPORATION FOR ANY PURPOSE WHATSOEVER EXCEPT WITH THE THEREOF SHALL BE UTILIZED BY ANY PERSON, FIRM, OR ENGINEERING & LANDSCAPE ARCHITECTURE, P.C. AND NO PART OWNED BY AND REMAIN THE PROPERTY OF SWBR ARCHITECTURE, AND PLANS INDICATED THEREON OR PRESENTED THEREBY ARE THESE DOCUMENTS AND ALL THE IDEAS, ARRANGEMENTS, DESIGNS 387 East Main Street Rochester, NY 14604-2107 Voice: 585.232.8300 Fax: 585.232.9221 w w w . s w b r . c o m FILE PATH:ROCHESTER, N E W Y O R K CONSULTANT PROJECT: CLIENT: DRAWING TITLE proj. no. checked proj. mgr. drawn by STATUS: DRAWING NO. ISSUE DATE:3/26/2014 9:49:24 AMC:\1-Local Revit Models 2014\13465.00_120Maple RTU Replacement_Central_kristins.rvtCORNELL UNIVERSITY REVISIONS no.date by description ENGINEERING P.C. MECHANICAL/ELECTRICAL ENGINEERING CONSULTANTS ROCHESTER, NEW YORK 14604 (585) 288-5590 FAX: (585) 288-0233 M/E Project 130267 150 NORTH CHESTNUT STREET ROCHESTER BUFFALO SYRACUSE CAPITAL DISTRICT JAD 13465.00 CIT RENOVATIONS 06/27/2014 DOCUMENTS 100% CONSTRUCTION ED-101 MRG MRG 120 MAPLE J (E) (E) LRPGC2 LRPGC1 J J J J J J J J WAP WAP J NORTH 0SCALE: 1/4"=1’-0"2’4’8’ DEMOLITION NOTES: 3 3 3 1 3 3 22 22 2 PARTIAL GROUND FLOOR PLAN - ELECTRICAL DEMOLITION1 F S S S F S (E) (E)(E) (E) (E)(E) (E) (E) (E) (E) (E) (E) (E) (E) (E)(E) (E)(E)(E) (E) (E) (E) (E) (E)(E)(E)(E) (E) (E) (E) (E) (E) (E) (E) (E)(E) (E)(E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E)(E)(E)(E) (E)(E)(E) (E)(E) (E)(E) (E)(E) (E) (E) ELECTRICAL DEMOLTION GROUND FLOOR PL AN - 120 MAPLE - PARTIAL ED-101 (E) (E) 1 2 3 1 1 1 1 1 PREWIRED FURNITURE. FURNITURE. SALVAGE EXISTING DATA AT JUNCTION BOXES USED FOR CONNECTIONS TO SALVAGE EXISTING POWER AT JUNCTION BOXES USED FOR CONNECTIONS TO PREWIRED MOUNTED AT 84" AFF. CONNECTION TO PREWIRED FURNITURE. (ER) (ER) (ER) (ER)(ER) B. A. GENERAL NOTES: ALL 120V CIRCUITS FOR THIS PROJECT AREA ORIGINATE FROM PANELS LRPGC1 AND LRPGC2. ALL CIRCUITS NOT REUSED SHALL BE REMOVED BACK TO SOURCE. SALVAGE EXISTING LIGHTING AND POWER CIRCUITS FOR REUSE AND EXTENSION. SUITE OFFICE G32 ROOM G32A OFFICE G32B CORRIDOR G00CC SVC LVL 2 G34 VACANT G40CORRIDOR G00CD CORRIDOR G00CE WOMEN G00TC ELEV MACHINE MGT SVC LVL 3 & IDENT G37 OFFICE G30 OFFICE SUITE G41 LOBBY G00LA STOR G00UA ELEV G00EA ALL RIGHTS RESERVED ' ENGINEERING & LANDSCAPE ARCHITECTURE, P.C.. SPECIFIC WRITTEN PERMISSION OF SWBR ARCHITECTURE, CORPORATION FOR ANY PURPOSE WHATSOEVER EXCEPT WITH THE THEREOF SHALL BE UTILIZED BY ANY PERSON, FIRM, OR ENGINEERING & LANDSCAPE ARCHITECTURE, P.C. AND NO PART OWNED BY AND REMAIN THE PROPERTY OF SWBR ARCHITECTURE, AND PLANS INDICATED THEREON OR PRESENTED THEREBY ARE THESE DOCUMENTS AND ALL THE IDEAS, ARRANGEMENTS, DESIGNS 387 East Main Street Rochester, NY 14604-2107 Voice: 585.232.8300 Fax: 585.232.9221 w w w . s w b r . c o m FILE PATH:ROCHESTER, N E W Y O R K CONSULTANT PROJECT: CLIENT: DRAWING TITLE proj. no. checked proj. mgr. drawn by STATUS: DRAWING NO. ISSUE DATE:3/26/2014 9:49:24 AMC:\1-Local Revit Models 2014\13465.00_120Maple RTU Replacement_Central_kristins.rvtCORNELL UNIVERSITY REVISIONS no.date by description ENGINEERING P.C. MECHANICAL/ELECTRICAL ENGINEERING CONSULTANTS ROCHESTER, NEW YORK 14604 (585) 288-5590 FAX: (585) 288-0233 M/E Project 130267 150 NORTH CHESTNUT STREET ROCHESTER BUFFALO SYRACUSE CAPITAL DISTRICT JAD 13465.00 CIT RENOVATIONS 06/27/2014 DOCUMENTS 100% CONSTRUCTION 1 J J J J J J CLG CLG CLG CLG DSD F F H H S DEMOLITION NOTES: 1 H H H S S F F F F F F CLG CLG CLG CLG CLG CLG CLG CLG CLG CLG CLG CLG CLG ECBECBECBECB M M DSD RTS CONTROLS AHU TTTT T PPPP-1 LP-1 PP-2 MDP ED-102 NAIC MRG MRG S F NORTH 0SCALE: 1/4"=1’-0"2’4’8’ 1 PARTIAL FIRST FLOOR PLAN - ELECTRICAL DEMOLITION 2 2 M M CR M D (E) (E)(E)(E) (E) (E)(E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E)(E) (E)(E)(E) (E) (E) (E) (E) (E) (E) (E) (E)(E)(E) CUH OPERATOR DOOR OPERATOR DOOR 3 3 FACP (E) 4 S F (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) 5 5 ED-102 (E) (E) (E) (E) (E) (E) (E) (E) (E) (ER) (ER) (ER) (E) (E) (E) (E) (E)(E)(E) (E) (E) (E) ELECTRICAL DEMOLTION FIRST FLOOR PLAN - 120 MAPLE - PARTIAL RTS DSD 6 6 CONDUIT WITH EXISTING CABLES TO REMAIN. OTHER WILL BE USED TO FEED ALL NEW DEVICES WITH OVERFLOW GOING TO EXISTING AREA. ONE 3" CONDUIT FEEDS EXISTING TEL/DATA DEVICES SCHEDULED TO REMAIN. THE APPROXIMATE LOCATION WHERE (2)3" CONDUITS TO TEL/DATA ROOM ENTER INTO PROJECT THERE ARE APPROXIMATELY (10) CIRCUITS TO BE RELOCATED. ALL EXISTING CIRCUITS TO MATCH EXISTING CIRCUIT TYPES TO NEW DISTRIBUTION. SHALL BE REFED FROM NEW ELECTRICAL DISTRIBUTION BEING INSTALLED. EXTEND ALL EXISTING TO REMAIN CIRCUITS FED FROM THIS ELECTRICAL ROOM DISTRIBUTION FROM DUST AND DEBRIS. SHALL BE COORDINATED WITH OWNER AND ALL EXISTING SERVICES PROTECTED DOWN THROUGH FLOOR TO NAIC SPACE BELOW. ALL WORK WITHIN CER FEED ROUTES ACROSS ROOF AND INTO SECOND FLOOR CER CLOSET AND THEN FEEDERS AND CONTROL DEVICES BACK TO SOURCE. AHU IS FED FROM PANEL PP. DISCONNECT AND REMOVE ALL POWER REMOVE FEEDER BACK TO PANEL. REFER TO DRAWING E-101 FOR PANEL LOCATION. 225KVA TRANSFORMER FED FROM MDP LOCATED IN ELECTRICAL ROOM GOOUB. EXISTING FCI 7200 FACP IN FIRST FLOOR VESTIBULE BELOW.A. GENERAL NOTES: THE PROJECT AREA TO PROVIDE FULL COVERAGE. FOR THE DURATION OF THE PROJECT PROVIDE HEAT DETECTORS THROUGHOUT 170A 170B 170C 100CG 170E 170 170G 160A 170F 160 LOADING 160B 132 WOMEN 100TC STAIR 100SE VEST 100CB STAIR 100SD BREAK ROOM 133 LOBBY 100LA CORRIDOR 100CC ROOM CONFERENCE 156 ROOM CONFERENCE 130 ELEV 100EA VEST 100CE ALL RIGHTS RESERVED ' ENGINEERING & LANDSCAPE ARCHITECTURE, P.C.. SPECIFIC WRITTEN PERMISSION OF SWBR ARCHITECTURE, CORPORATION FOR ANY PURPOSE WHATSOEVER EXCEPT WITH THE THEREOF SHALL BE UTILIZED BY ANY PERSON, FIRM, OR ENGINEERING & LANDSCAPE ARCHITECTURE, P.C. AND NO PART OWNED BY AND REMAIN THE PROPERTY OF SWBR ARCHITECTURE, AND PLANS INDICATED THEREON OR PRESENTED THEREBY ARE THESE DOCUMENTS AND ALL THE IDEAS, ARRANGEMENTS, DESIGNS 387 East Main Street Rochester, NY 14604-2107 Voice: 585.232.8300 Fax: 585.232.9221 w w w . s w b r . c o m FILE PATH:ROCHESTER, N E W Y O R K CONSULTANT PROJECT: CLIENT: DRAWING TITLE proj. no. checked proj. mgr. drawn by STATUS: DRAWING NO. ISSUE DATE:3/26/2014 9:49:24 AMC:\1-Local Revit Models 2014\13465.00_120Maple RTU Replacement_Central_kristins.rvtCORNELL UNIVERSITY REVISIONS no.date by description ENGINEERING P.C. MECHANICAL/ELECTRICAL ENGINEERING CONSULTANTS ROCHESTER, NEW YORK 14604 (585) 288-5590 FAX: (585) 288-0233 M/E Project 130267 150 NORTH CHESTNUT STREET ROCHESTER BUFFALO SYRACUSE CAPITAL DISTRICT JAD 13465.00 CIT RENOVATIONS 06/27/2014 DOCUMENTS 100% CONSTRUCTION ED-103 MRG MRG CCC S IC H J J S S WAP F S (E) (E)(E) (E)(E) (E) (E) (E) (E) (E)J SECT 1 PP-N1-2 SECT 2 PP-N1-2 CPC-6E CPC-6D WAP J J (E)(E) FACP FACP 11 NORTH 0SCALE: 1/4"=1’-0"2’4’8’ 1 PARTIAL FIRST FLOOR PLAN - ELECTRICAL DEMOLITION DEMOLITION NOTES: 1 WAP (E) (E) JJ S D S D S S F S S S (E) (E)(E) (E) (E) (E) (E)(E) (E)(E) (E) (E) (E) (E) (E)(E)(E) (E) (E) (E) (E) (E) (E) (E)(E) (E) (E)(E)(E)(E) (E)(E)(E) (E)(E)(E) (E) (E)(E)(E) (E) (E) (E)(E) (E)(E) (E) (E) (E) (E) (E)(E) (E)(E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E)(E) (E)(E) (E)(E)(E) (E)(E) (E) (E) (E) (E) (E)(E) (E) PLAN FOR NEW SWITCHING. EXISTING LIGHTING IN THIS SPACE TO REMAIN BUT CONTROLS TO BE MODIFIED BASED ON NEW LAYOUT. REFER TO NEW WORK EXISTING FCI ZONED FIRE ALARM CONTROL PANELS ARE LOCATED ON GROUND FLOOR ROOM B0041 DIRECTLY BELOW THIS ROOM. 2 2 2 2 2 2 (E)(E)(E) ELECTRICAL DEMOLTION FLOOR PLAN - CCC - PARTIAL FIRST J J J J J J J J (E) (E) (E) (E) (E) (E) (E) (E) (E)(E)(E)(E) ED-103 A. GENERAL NOTES: ALL CIRCUITS NOT REUSED SHALL BE REMOVED BACK TO SOURCE. SALVAGE EXISTING LIGHTING AND POWER CIRCUITS FOR REUSE AND EXTENSION. ALL RIGHTS RESERVED ' ENGINEERING & LANDSCAPE ARCHITECTURE, P.C.. SPECIFIC WRITTEN PERMISSION OF SWBR ARCHITECTURE, CORPORATION FOR ANY PURPOSE WHATSOEVER EXCEPT WITH THE THEREOF SHALL BE UTILIZED BY ANY PERSON, FIRM, OR ENGINEERING & LANDSCAPE ARCHITECTURE, P.C. AND NO PART OWNED BY AND REMAIN THE PROPERTY OF SWBR ARCHITECTURE, AND PLANS INDICATED THEREON OR PRESENTED THEREBY ARE THESE DOCUMENTS AND ALL THE IDEAS, ARRANGEMENTS, DESIGNS 387 East Main Street Rochester, NY 14604-2107 Voice: 585.232.8300 Fax: 585.232.9221 w w w . s w b r . c o m FILE PATH:ROCHESTER, N E W Y O R K CONSULTANT PROJECT: CLIENT: DRAWING TITLE proj. no. checked proj. mgr. drawn by STATUS: DRAWING NO. ISSUE DATE:3/26/2014 9:49:24 AMC:\1-Local Revit Models 2014\13465.00_120Maple RTU Replacement_Central_kristins.rvtCORNELL UNIVERSITY REVISIONS no.date by description ENGINEERING P.C. MECHANICAL/ELECTRICAL ENGINEERING CONSULTANTS ROCHESTER, NEW YORK 14604 (585) 288-5590 FAX: (585) 288-0233 M/E Project 130267 150 NORTH CHESTNUT STREET ROCHESTER BUFFALO SYRACUSE CAPITAL DISTRICT JAD 13465.00 CIT RENOVATIONS 06/27/2014 DOCUMENTS 100% CONSTRUCTION FEC FEC FECC STORAGE - 121 STOR. - A STOR. - B WORK AREA 119 OFFICE 119A OFFICE 118A OFFICE 118B ATC ROOM 124 OFFICE 126 OFFICE 126C OFFICE 126B OFFICE 126A OFFICE 118 BATTERY ROOM 103 EC 10062 VIDEO EDITING 125MEN 10020 CLOSET WOMEN 10021 CORRIDOR 10042CORRIDOR 10040 CORR 10041 CORRIDOR 10046 CORRIDOR 10060 STAIR 10001 VEST 10043 STAIR 10002 10044 TC 10064 PROGRAM SPACE TECHNOLOGY ACADEMIC 123 E-100 MRG MRG 110 MAPLE NORTH 0SCALE: 1/4"=1’-0"2’4’8’ 1 PARTIAL FIRST FLOOR PLAN - ELECTRICAL NEW WORK (E) (E) (E)(E) (E)F (E) (E) S(E) (E) (E) PP4 (E) F (E) (E) (E)FACPDOOR ACCESS PANEL (E) MDP1 (E) (E) PP1 PP2 (E) DRAWING NOTES: 1 33 3 3 4 2 1 EM EM EM X1 FS2 FS2 FS2 FS2 FS2 FS2 FS2 FS2 FS1 FS1 FS1 S S S S F F 2 M M M M EF-1 DSS-1 ELECTRICAL NEW WORK FIRST FLOOR PLAN - 110 MAPLE - PARTIAL F (E) (E) WAP (E) E-100 1133 3 5 2 ACCU-1 DSS-2 NL 3 3 3 3D. C. B. A. GENERAL NOTES: 20A-1P CIRCUITS TO CONNECT CIRCUITS TO. INDICATED. CIRCUIT NUMBER ONLY PROVIDED FOR GROUPING OF CIRCUITS. UTILIZE EXISTING SPARE ALL NEW 120V RECEPTACLE CIRCUITS SHALL BE FED FROM EXISTING PANEL PP2, CIRCUIT NUMBER AS CONNECT ALL NEW NIGHT LIGHTS TO EXISTING NIGHT LIGHT CIRCUIT WITHIN FACILITY. CONNECT ALL NEW EXIT SIGNS TO EXISTING EXIT SIGN CIRCUIT WITHIN FACILITY. CONNECT ALL NEW EMERGENCY BATTERY PACKS TO EXISTING BATTERY PACK CIRCUIT WITHIN FACILITY. OSOS OS OS 4 4 6 6 FS2 FS2 MTD CLG7 F 2 5 5 6 7 4 4 5 6 6 7 8 PROVIDE DEVICES FLUSH IN CEILING. COORDINATE FINAL LOCATION WITH ARCHITECTURAL DRAWINGS. PROVIDE WIREMOLD 5500 SERIES RACEWAY WITH ALL ACCESSORIES. PROVIDE A CHIEF BACK BOX MODEL PAC516. REFER TO ARCHITECTURAL DRAWINGS FOR ELEVATIONS. REFER TO DETAIL #9 ON DRAWING E-401 FOR DOOR HARDWARE PREP FOR FUTURE KEYPAD. FOR NEW LIGHTING AND CONTROLS. UTILIZED SALVAGED LIGHTING CIRCUIT. REWORK AND EXTEND EXISTING CIRCUITING AS REQUIRED REQUIRED TO INSTALL NEW SWITCH. PROVIDE NEW SWITCH TO CONTROL EXERIOR LIGHT. REWORK AND EXTEND EXISTING FEED AS THIS LOCATION AT THE CEILING LEVEL. ALL NEW DATA CABLES SHALL BE ROUTED TO EXISTING CONDUIT SLEEVES AT APPROXIMATELY REF.STORAGE 110A CTOC 110 OFFICE 106 OFFICE 107 OFFICE 109 BREAK 105 OFFICE 104 OFFICE 104A OFFICE 102 OFFICE 101 CONFERENCE ROOM BREAK 113A OFFICE 108 TOILET 100TA MECH 100UA COPY ROOM 113 SERVER 111 CORR 3 TOILET 100TB CORRIDOR 100CA ALL RIGHTS RESERVED ' ENGINEERING & LANDSCAPE ARCHITECTURE, P.C.. SPECIFIC WRITTEN PERMISSION OF SWBR ARCHITECTURE, CORPORATION FOR ANY PURPOSE WHATSOEVER EXCEPT WITH THE THEREOF SHALL BE UTILIZED BY ANY PERSON, FIRM, OR ENGINEERING & LANDSCAPE ARCHITECTURE, P.C. AND NO PART OWNED BY AND REMAIN THE PROPERTY OF SWBR ARCHITECTURE, AND PLANS INDICATED THEREON OR PRESENTED THEREBY ARE THESE DOCUMENTS AND ALL THE IDEAS, ARRANGEMENTS, DESIGNS 387 East Main Street Rochester, NY 14604-2107 Voice: 585.232.8300 Fax: 585.232.9221 w w w . s w b r . c o m FILE PATH:ROCHESTER, N E W Y O R K CONSULTANT PROJECT: CLIENT: DRAWING TITLE proj. no. checked proj. mgr. drawn by STATUS: DRAWING NO. ISSUE DATE:3/26/2014 9:49:24 AMC:\1-Local Revit Models 2014\13465.00_120Maple RTU Replacement_Central_kristins.rvtCORNELL UNIVERSITY REVISIONS no.date by description ENGINEERING P.C. MECHANICAL/ELECTRICAL ENGINEERING CONSULTANTS ROCHESTER, NEW YORK 14604 (585) 288-5590 FAX: (585) 288-0233 M/E Project 130267 150 NORTH CHESTNUT STREET ROCHESTER BUFFALO SYRACUSE CAPITAL DISTRICT JAD 13465.00 CIT RENOVATIONS 06/27/2014 DOCUMENTS 100% CONSTRUCTION E-101 MRG MRG 120 MAPLE F F S S S S (E) (E) (E) (E) (E) (E) (E) (E) (E) (E)(E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E)(E) (E) (E) (E)(E)(E) (E) (E) (E) (E) (E) (E) (E) NORTH 0SCALE: 1/4"=1’-0"2’4’8’ 1 PARTIAL GROUND FLOOR PLAN - ELECTRICAL NEW WORK (E) (E) LRPGC2 LRPGC1 T T HELP HPPG MDP LPPG2 LPPG1 LPPGA-1 LPPGA-2 LPPGB (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) 1 1 DRAWING NOTES: 1 2 2 3 3 3 3 4 4 4 3 4 (E) (E)(E) (E)(E) (E)(E) (E)(E) (E)(E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) ELECTRICAL NEW WORK GROUND FLOOR PL AN - 120 MAPLE - PARTIAL J J J J J (ER)(ER) (ER) (ER) (ER) 5 5 5 5 5 5 COORDINATED IN FIELD WITH A MINIMUM OF THREE TEL/DATA BOXES PER LOCATION. EXISTING JUNCTION BOX WITH 1" CONDUITS. FINAL QUANTITY OF BOXES REQUIRED SHALL BE LOCATED AT THE JUNCTION BOX. EACH OF THE TEL/DATA BOXES SHALL BE CONNECTED TO THE PROVIDE AT EACH JUNCTION BOX, TEL/DATA BOXES TO ACCOMMODATE ALL EXISTING DATA CABLES LOCATION OF EXISTING JUNCTION BOXES TO BE USED TO FEED SURFACE MOUNTED RACEWAY. EXISTING DEVICES MOUNTED AT 84" AFF. EQUAL AMOUNT OF RECEPTACLES ON EACH EXISTING CIRCUIT WITHIN JUNCTION BOX. UTILIZE AND EXTEND EXISTING CIRCUITS FROM JUNCTION BOXES UP TO RACEWAY. PROVIDE AN SHALL FED WITH POWER FROM EXISTING JUNCTION BOXES MOUNTED AT FLOOR BELOW RACEWAY. PROVIDE DUPLEX RECEPTACLE EVERY 3’ FOR SURFACE MOUNTED RACEWAY. SURFACE RACEWAY MOUNT DEVICES IN A FSR WALL BOX. COORDINATE HEIGHT WITH ARCHITECTURAL PLANS. A COMPLETE SYSTEM. OVERFLOOR RACEWAY 4-GANG BOX UNDER TABLE. PROVIDE ALL REQUIRED ACCESSORIES FOR PROVIDE WIREMOLD OFR SERIES OVERFLOOR RACEWAY FROM WALL TO UNDER TABLE. PROVIDE 6 6 6 6 6 6 E-101 15 17 19 A. GENERAL NOTES: CIRCUIT NUMBER AS INDICATED. ALL NEW RECEPTACLES SHALL BE FED FROM EXISTING PANEL LRPGC2, SUITE OFFICE G32 STORAGE G36 SERVICE CONFERENCE VIDEO G38C GROUP SERVICE GROUP SERVICE SUPPORT TECH G38A ELECTRICAL G00UB ROOM STOCK G44 OFFICE ROOM CONFERENCE G50 SUITE OFFICE G41 STORAGE G40 KITCHEN G00UAG35 SUITE OFFICE G34 OFFICE G32A OFFICE G32B SUITE OFFICE G37 OFFICE OFFICE KITCHEN WOMENS MENSCOATS STAR G00SB JAN ALL RIGHTS RESERVED ' ENGINEERING & LANDSCAPE ARCHITECTURE, P.C.. SPECIFIC WRITTEN PERMISSION OF SWBR ARCHITECTURE, CORPORATION FOR ANY PURPOSE WHATSOEVER EXCEPT WITH THE THEREOF SHALL BE UTILIZED BY ANY PERSON, FIRM, OR ENGINEERING & LANDSCAPE ARCHITECTURE, P.C. AND NO PART OWNED BY AND REMAIN THE PROPERTY OF SWBR ARCHITECTURE, AND PLANS INDICATED THEREON OR PRESENTED THEREBY ARE THESE DOCUMENTS AND ALL THE IDEAS, ARRANGEMENTS, DESIGNS 387 East Main Street Rochester, NY 14604-2107 Voice: 585.232.8300 Fax: 585.232.9221 w w w . s w b r . c o m FILE PATH:ROCHESTER, N E W Y O R K CONSULTANT PROJECT: CLIENT: DRAWING TITLE proj. no. checked proj. mgr. drawn by STATUS: DRAWING NO. ISSUE DATE:3/26/2014 9:49:24 AMC:\1-Local Revit Models 2014\13465.00_120Maple RTU Replacement_Central_kristins.rvtCORNELL UNIVERSITY REVISIONS no.date by description ENGINEERING P.C. MECHANICAL/ELECTRICAL ENGINEERING CONSULTANTS ROCHESTER, NEW YORK 14604 (585) 288-5590 FAX: (585) 288-0233 M/E Project 130267 150 NORTH CHESTNUT STREET ROCHESTER BUFFALO SYRACUSE CAPITAL DISTRICT JAD 13465.00 CIT RENOVATIONS 06/27/2014 DOCUMENTS 100% CONSTRUCTION E-102 NAIC MRG MRG S F M M CR M (E) (E)(E)(E) (E) (E)(E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E)(E) (E)(E)(E) (E) (E) (E) (E) (E) (E) (E) (E)(E)(E) CUH OPERATOR DOOR OPERATOR DOOR S F(E) (E) (E) (E) (E) (E) (E) (E)FACP F F F F F F F F F F F F F F F T1HP-1 LP-1 FS1 WAP WAPWAP NORTH 0SCALE: 1/4"=1’-0"2’4’8’ 1 PARTIAL FIRST FLOOR PLAN - ELECTRICAL NEW WORK 2 3 DRAWING NOTES: 1 2 3 (E) (E) (E) (E) EM EM EM EM X1 X1 X1 X1 X1 4 5 6 J J J J J 6 6 6 6 6 ELECTRICAL NEW WORK FIRST FLOOR PLAN - 120 MAPLE - PARTIAL (E) (E) (E) (E) (E) D (E) (E) (E) (E) (E) (E) (E) (E)(E)(E) (E) (E) (E) (E) X1 1 1 (ER) (ER) (ER) J 6 J 6 S S S S S S S S S S NL NL NL NL NL NL NL MTD. CLG. 5 E-102 FR3 FR2 FR3 FR3FR3 FR3 FR3 FR3 FR3 FR3 FR3 FR3 FR3 FR3 FR3 FR3 FR3 FR3 FR3 FR3 FR3 FR3 FR3 FR3 FR3 FR3 FR3 FR3 FR3FR3FR3 FR3FR3 FR3 FR3FR3FR3FR3 FR3 FR3 FR3FR3 FR3 FR3 FR3 FR3 FR3FR3 FR3 FR3 FR3 FR3 FR2 FR2 FR33 4 4 3OS OS OS OS OS OS OS OS OS OS OS OS OS OS OS OS OS OSOS OS OS OS OS FR3 FR3 FR3 FR3 FR3 (E) (E) (E) (E) (E) (E) (E) (E) DSD RTS DSD RTS SD SD DSD RTS 1 1 1 1 3 3 5 5 5 7 7 7 7 9 9 11 11 11 11 11 12 12 12 12 13 13 1313 15 15 17 19 19 19 19 19 19 21 21 21 21 23 23 23 25 27 29 2414141 41 41 31 33 35 37 39 39 4 4 4 39 39 39 J JJ LP-1 LP-1LP-1 6 8 10 4 4 4 HH H OFFICE 165 QUIET AREA 167 OFFICE 169 CORR 100CG STAIR 100SD ROOM CONFERENCE DIRECTOR’S 171 OFFICE 173 OFFICE 175 OFFICE 172 PROJECT AREA 168 OFFICE 166 OFFICE 160C OPEN OFFICE 160 STAIR 100SE ROOM SMALL MEETING 160B SECURE ROOM 160A ROOM CONFERENCE 156 ROOM CONFERENCE 130 CORRIDOR 100CC BREAK ROOM WOMEN LOBBY 100LA VEST 132 6"C/T 6"C/T 6"C/T 6"C/T6"C/T6"C/TS ELECTRICAL 100UB CORRIDOR 100CH F. E. D. C. B. A. GENERAL NOTES: REFER TO ARCHITECTURAL PLANS FOR ALL DEVICES AND AV EQUIPMENT ELEVATIONS. CONNECT ALL NEW NORMAL POWER, NON EGRESS, LIGHTING TO PANEL HP-1, CIRCUIT #5. INDICATED. ALL NEW 120V RECEPTACLE CIRCUITS SHALL BE FED FROM PANEL LP-1, CIRCUIT NUMBER AS CONNECT ALL NEW NIGHT LIGHTS TO PANEL HP-1, CIRCUIT #3. CONNECT ALL NEW EXIT SIGNS TO PANEL HP-1, CIRCUIT #1. CONNECT ALL NEW EMERGENCY BATTERY PACKS TO NEAREST CORRIDOR RECEPTACLE CIRCUIT. PROVIDE A DOUBLE GNAG JUNCTION BOX AT 48" AFF WITH 1" CONDUIT TO ABOVE FINISHED CEILING. CEILING. PROVIDE A NEMA 12" X 12" X 4" AV BACK BOX AT 15" AFF. PROVIDE (2) 1" CONDUITS TO ABOVE FINISHED CONDUIT TO CHIEF BACK BOX. PROVIDE A VADDIO CAMERA BACKBOX MODEL 999-2225-018 BOX, FRAME AND PLATFORM WITH A 1" TO ABOVE FINISHED CEILING. PROVIDE A CHIEF BACK BOX MODEL PAC516 AT 60" AFF WITH DEVICES AS SHOWN AND A 1" CONDUIT CEILING. PROVIDE A DOUBLE GANG JUNCTION BOX ABOVE 70" DISPLAY WITH A 1" CONDUIT ABOVE FINISHED PROVIDE A DOUBLE GANG JUNCTION BOX AT 48" AFF WITH 1" CONDUIT TO ABOVE FINISHED CEILING. PROVIDE CONNECTION FOR POWER AND 2" CONDUIT FOR TEL/DATA AT PREWIRED FURNITURE. SHALL TERMINATE. APPROXIMATE LOCATION EXISTING PAIR OF 3" CONDUITS TO TEL/DATA ROOM WHERE CABLE TRAY EXACT LOCATION WITH MECHANICAL CONTRACTOR. PROVIDE DEDICATED 120V, 20A BRANCH CIRCUIT TO JUNCTION BOX FOR VAV CONTROLS. COORDINATE DRAWINGS. DEVICES WILL BE SURFACE MOUNTED ON EXISTING MASONRY WALL. MOUNT DEVICES ABOVE LCD SCREEN. COORDINATE MOUNTING HEIGHT WITH ARCHITECTURAL EXISTING FCI 7200 FACP IN FIRST FLOOR VESTIBULE BELOW. POINT AT EACH BOX. PROVIDE A 1.25" CONDUIT TO SERVE AV PORTION OF OVER FLOOR RACEWAY. COMPLETE SYSTEM. PROVIDE A DUPLEX RECEPTACLE, (1) DATA DROP AND (1) AV CONNECTION OVERFLOOR RACEWAY 4-GANG BOX UNDER TABLE. PROVIDE ALL REQUIRED ACCESSORIES FOR A PROVIDE WIREMOLD OFR SERIES OVERFLOOR RACEWAY FROM WALL TO UNDER TABLE. PROVIDE 7 8 9 10 11 12 J J J J 7 8 9 10 12 11 9 3 17 17 ALL RIGHTS RESERVED ' ENGINEERING & LANDSCAPE ARCHITECTURE, P.C.. SPECIFIC WRITTEN PERMISSION OF SWBR ARCHITECTURE, CORPORATION FOR ANY PURPOSE WHATSOEVER EXCEPT WITH THE THEREOF SHALL BE UTILIZED BY ANY PERSON, FIRM, OR ENGINEERING & LANDSCAPE ARCHITECTURE, P.C. AND NO PART OWNED BY AND REMAIN THE PROPERTY OF SWBR ARCHITECTURE, AND PLANS INDICATED THEREON OR PRESENTED THEREBY ARE THESE DOCUMENTS AND ALL THE IDEAS, ARRANGEMENTS, DESIGNS 387 East Main Street Rochester, NY 14604-2107 Voice: 585.232.8300 Fax: 585.232.9221 w w w . s w b r . c o m FILE PATH:ROCHESTER, N E W Y O R K CONSULTANT PROJECT: CLIENT: DRAWING TITLE proj. no. checked proj. mgr. drawn by STATUS: DRAWING NO. ISSUE DATE:3/26/2014 9:49:24 AMC:\1-Local Revit Models 2014\13465.00_120Maple RTU Replacement_Central_kristins.rvtCORNELL UNIVERSITY REVISIONS no.date by description ENGINEERING P.C. MECHANICAL/ELECTRICAL ENGINEERING CONSULTANTS ROCHESTER, NEW YORK 14604 (585) 288-5590 FAX: (585) 288-0233 M/E Project 130267 150 NORTH CHESTNUT STREET ROCHESTER BUFFALO SYRACUSE CAPITAL DISTRICT JAD 13465.00 CIT RENOVATIONS 06/27/2014 DOCUMENTS 100% CONSTRUCTION E-103 MRG MRG CCC NORTH 0SCALE: 1/4"=1’-0"2’4’8’ 1 PARTIAL FIRST FLOOR PLAN - ELECTRICAL NEW WORK CPC-6D (E) (E) CPC-6E (E)J (E) SECT 1 PP-N1-2 (E) SECT 2 PP-N1-2 (E) (E) (E) (E)(E) (E) (E) CPC-6D (E) (E) CPC-6E (E)J (E) SECT 1 PP-N1-2 (E) SECT 2 PP-N1-2 (E) (E) (E) (E)(E) (E) (E) WAP (E) (E)(E) (E)(E) (E) (E) (E) (E) (E)J SECT 1 PP-N1-2 SECT 2 PP-N1-2 CPC-6E CPC-6D WAP (E) (E) S D S D S S F S S S (E) (E)(E) (E) (E) (E) (E)(E) (E)(E) (E) (E) (E) (E) (E)(E)(E) (E) (E) (E) (E) (E) (E) (E)(E) (E) (E)(E)(E)(E) (E)(E)(E) (E)(E)(E) (E) (E)(E)(E) (E) (E) (E)(E) (E)(E) (E) (E) (E) (E) (E)(E) (E)(E) (E) (E) (E) (E) (E) (E) (E) (E)(E) (E)(E) (E)(E)(E) (E)(E) (E) (E) (E) (E) (E)(E) (E) (E)(E)(E) OSOS OSOS DRAWING NOTES: 1 OS OS S S F F (E) S S F S S FR1 FR1 FR2 FR2FR3 FR3 FR3 FR3FR3 1 ELECTRICAL NEW WORK FLOOR PLAN - CCC - PARTIAL FIRST (E)(E)(E)(E) E-103 C. B. A. GENERAL NOTES: CONNECT ALL NEW NIGHT LIGHTS TO EXISTING NIGHT LIGHT CIRCUIT WITHIN FACILITY. CONNECT ALL NEW EXIT SIGNS TO EXISTING EXIT SIGN CIRCUIT WITHIN FACILITY. CONNECT ALL NEW EMERGENCY BATTERY PACKS TO EXISTING BATTERY PACK CIRCUIT WITHIN FACILITY. 1 1 3 3 3 3 5 5 5 5 777799 9 11111111 3 3 5 5 1 22 22 22 24 24 2 3 4 5 NL PP-N1-3 EM EM REQUIRED FOR NEW CONTROLS AND LIGHT FIXTURE LOCATIONS. CONNECT NEW LIGHTING INTO EXISTING SALVAGED LIGHTING CIRCUIT. EXTEND AND REWORK AS FOR THIS AREA. CIRCUIT NUMBERS PROVIDED FOR GROUPING OF CIRCUITS ONLY. ALL NEW 120V CIRCUITS TO BE FED FROM PANEL PP-N1-3 SECTION 2, CIRCUIT NUMBER AS INDICATED AREA. CIRCUIT NUMBERS PROVIDED FOR GROUPING OF CIRCUITS ONLY. ALL NEW 120V CIRCUITS TO BE FED FROM PANEL CPC-6E, CIRCUIT NUMBER AS INDICATED FOR THIS FOR THIS AREA. CIRCUIT NUMBERS PROVIDED FOR GROUPING OF CIRCUITS ONLY. ALL NEW 120V CIRCUITS TO BE FED FROM PANEL PP-N1-2 SECTION 1, CIRCUIT NUMBER AS INDICATED CONTROLS. REMOVE AND REINSTALL LIGHT FIXTURES AS REQUIRED TO REWORK CIRCUITING TO NEW LIGHTING REWORK EXISTING LIGHT FIXTURE CIRCUITING TO HAVE ALL FIXTURES CONTROLLED VIA ONE SWITCH. PROVIDE NEW LIGHT SWITCH AND CEILING MOUNTED OCCUPANCY SENSORS FOR THE SPACE. 2 3 4 5 WAP (E) (E) (E) F ALL RIGHTS RESERVED ' ENGINEERING & LANDSCAPE ARCHITECTURE, P.C.. SPECIFIC WRITTEN PERMISSION OF SWBR ARCHITECTURE, CORPORATION FOR ANY PURPOSE WHATSOEVER EXCEPT WITH THE THEREOF SHALL BE UTILIZED BY ANY PERSON, FIRM, OR ENGINEERING & LANDSCAPE ARCHITECTURE, P.C. AND NO PART OWNED BY AND REMAIN THE PROPERTY OF SWBR ARCHITECTURE, AND PLANS INDICATED THEREON OR PRESENTED THEREBY ARE THESE DOCUMENTS AND ALL THE IDEAS, ARRANGEMENTS, DESIGNS 387 East Main Street Rochester, NY 14604-2107 Voice: 585.232.8300 Fax: 585.232.9221 w w w . s w b r . c o m FILE PATH:ROCHESTER, N E W Y O R K CONSULTANT PROJECT: CLIENT: DRAWING TITLE proj. no. checked proj. mgr. drawn by STATUS: DRAWING NO. ISSUE DATE:3/26/2014 9:49:24 AMC:\1-Local Revit Models 2014\13465.00_120Maple RTU Replacement_Central_kristins.rvtCORNELL UNIVERSITY REVISIONS no.date by description ENGINEERING P.C. MECHANICAL/ELECTRICAL ENGINEERING CONSULTANTS ROCHESTER, NEW YORK 14604 (585) 288-5590 FAX: (585) 288-0233 M/E Project 130267 150 NORTH CHESTNUT STREET ROCHESTER BUFFALO SYRACUSE CAPITAL DISTRICT JAD 13465.00 CIT RENOVATIONS 06/27/2014 DOCUMENTS 100% CONSTRUCTION FEC FEC FECOFFICE SUITE 118 OFFICE 118B OFFICE 118A OFFICE 126C OFFICE 126B OFFICE 126A LAB INSTRUCTIONAL TECH / ATC / COURSE 126 119A 119 EC 10062 VIDEO EDITING 125MEN 10020 CLOSET WOMEN 10021 CORRIDOR 10042CORRIDOR 10040 CORR 10041 CORRIDOR 10060 STAIR 10001 VEST 10043 STAIR 10002 10044 10064 (SUPPLY) POWER PANEL TRANSFORMER CONTROL HC (EQUIPMENT) CONNECTION MOTOR SWITCH (CONTROL UNIT) STARTER/DISCONNECT COMBINATION MAGNETIC WIRING SYSTEM FIRE ALARM MECHANICAL WORK PROVIDED UNDER CONTROL WIRING OL OL OL HC H O A OL BOND EQUIPMENT GROUND CONDUCTOR TO MOTOR FRAME. BOND EQUIPMENT GROUND CONDUCTOR TO ENCLOSURE. DISCONNECT SWITCH PROVIDED UNDER ELECTRICAL WORK. CONTROL DEVICES FURNISHED AND INSTALLED UNDER ELECTRICAL WORK. MOTOR STARTER FURNISHED AND INSTALLED UNDER ELECTRICAL WORK POWER WIRING AND CONNECTIONS PROVIDED UNDER ELECTRICAL WORK. 6 5 4 3 2 1 INDICATED) SWITCH (WHERE LOCAL DISCONNECT 1 1 1 4 5 3 DETAIL NOTES: SCALE: NONE TYPICAL THREE PHASE MOTOR CONNECTION1 E-401 SCALE: NONE TYPICAL RECEPTACLE IDENTIFICATION PANEL NUMBER BRANCH BREAKER NUMBER 1-CBLP-2-SHB#32 THE PLANS. NUMBER AS SHOWH ON THE SAME CIRCUIT AND NOT NECESSARILY SHALL BE AS INSTALLED CIRCUIT INFORMATION SUFFICIENT. ACTUAL WILL NOT BE FACTORY ADHESIVE USING CONTACT CEMENT. ADHERE TO COVERPLATE COLOR WITH OWNER, DYMO LABEL, VERIFY RECEPTACLES HORIZONTALLY MOUNTED OR TO LEFT OF OUTLET ON GROUNDING PIN ON TOP 1-CBLP-2-SHB#32TYPICAL 2 E-401 C. B. A. DETAIL NOTES: ENGRAVING ON THE RECEPTACLE COVERPLATE STATING "UPS POWER". FOR RECEPTACLES WHICH ARE FED FROM UPS POWER ALSO PROVIDE TO REDUCE SOUND TRANSMISSION. OUTLETS BACK TO BACK. INSTALL IN ADJACENT STUD CAVITIES, DO NOT INSTALL RECEPTACLES, COMPUTER OR TELEPHONE CONNECT TO GROUND BUS IN PANEL. PROVIDE GREEN GROUND WIRE IN ALL RECEPTACLE CIRCUITS. ARCHITECT FOR ALL OTHERS. 2. AS SELECTED BY 1. RED FOR EMERGENCY SHALL BE: RECEPTACLE COLOR MRG MRG SHEET DETAILS ELECTRICAL E-401 +24 VDC COMMON CONTROL OUTPUT RED BLACK BLUE BLUBLKREDPOWER/RELAY PACKBLK. WHT. LINE CKT. A WHT. NEUTRAL RED (LINE)RED (LOAD)SWITCH OFF LOAD LOAD LOAD LOAD SWITCH OFF SENSOR CEILING RED (LOAD) OUTPUT CONTROL COMMON +24 VDC SENSOR CEILING SWITCH OFF WHITE / NEUTRAL POWER/RELAY PACK NEUTRAL LINE SCALE: NONE CEILING MOUNTED OCCUPANCY SENSOR DUAL SWITCHED LOADSCALE: NONE CEILING MOUNTED OCCUPANCY SENSOR SINGLE SWITCHED LOAD J 7 SCALE: NONE 4 MOUNTED LUMINAIRES TYPICAL BRANCH CIRCUIT WIRING FOR CEILING 3 " EMT " EMT TYPICAL LUMINAIRE E-401 E-401 E-401 6’ LENGTH CONDUIT MAXIMUM 1/2" FLEXIBLE METAL 6’ LENGTH CONDUIT MAXIMUM 1/2" FLEXIBLE METALREDBLUBLKRED (LINE) WHT. BLK. RED BLK BLU LOAD SCALE: NONE WALL SWITCH MOUNTED OCCUPANCY SENSOR SENSOR OCCUPANCY WALL SWITCH MANUAL ON/OFF SWITCH LOAD NEUTRALWHT LINE E-401 5 LOAD SCALE: NONE 6 ENTRANCE OF PIPE OF POINT OF MADE WITHIN 5 FT CONNECTIONS TYPICAL GROUNDING DETAIL EQUIPMENT ENTRANCE SERVICE STEEL COLUMNS (#2/0 AWG CU) CONDUCTOR ELECTRODE GROUNDING WATER PIPE BY OTHERS) (METAL UNDERGROUND BAR GROUND BMGB BAR GROUND TMGB E-401 CER ROOMS TYPICAL FOR ALL MAIN ELECTRICAL ROOMS TYPICAL FOR ALL FIRE ALARM CONTROL PANEL FACP INTERFACE USER DISTRIBUTION PROGRAM SOFTWARE HARDWARE/ IDC’S SUPPLY POWER BATTERY TS F TS S H (INITIATING DEVICES) INPUTS AND EMERGENCY CONTROLS) (NOTIFICATION APPLIANCES OUTPUTS NAC’S CKT CITY F F FAN SHUTDOWN DH STATION OR CONTROL DEPARTMENT FIRE FAAP PRINTER F PHONE FIGHTER FIRE INTERFACE OR PC CRT/KBD W/BYPASS RELAYS AUX GAA ECCP DSD DSD RTS RTS SCALE: NONE 8 TYPICAL FIRE ALARM CONTROL PANEL SD E-401 FROM LIFE SAFETY PANEL EMERGENCY CIRCUITS DEDICATED 120V NOTES: 10 SCALE: NONE EQUIPMENT NAMEPLATE DETAIL PROVIDE SAMPLE NAMEPLATE FOR APPROVAL. TO BE 3/8". SPACE BETWEEN LINES SHALL BE 1/8" MINIMUM. MINIMUM SHALL BE 14"H X 8"W. TO THE EQUIPMENT WITH BRASS SCREWS. LETTERING SHALL BE 1/4" HIGH EXCEPT WARNING LINE NAMEPLATE SHALL BE ENGRAVED (WHITE LETTERING, BLACK BACKGROUND) AND ATTACHED SWITCHGEAR, ETC. PROVIDE CUSTOM NAMEPLATE AS INDICATED FOR ALL PANELBOARDS, SWITCHBOARDS, C. B. A. NEUTRAL-GRAY, GROUND-GREEN A-BROWN, B-ORANGE, C-YELLOW, NEUTRAL-WHITE, GROUND-GREEN, COLOR CODING: A-BLACK, B-RED, C-BLUE, 208/120V, 480/277V, ETC." VOLTAGE: "INSERT APPLICABLE VOLTAGE - EMERGENCY AS APPLICABLE" EQUIPMENT EMERGENCY, LIFE SAFETY TYPE SUPPLY: "INSERT- NORMAL, FED FROM: "INSERT SOURCE DESIGNATION" FEEDER: "INSERT FEEDER DESIGNATION" EQUIPMENT: "INSERT DESIGNATION" FLASH HAZARD WARNING: ARC FROM STUDY" PROHIBITED BOUNDARY: "INSERT DISTANCE FROM STUDY" RESTRICTED BOUNDARY: "INSERT DISTANCE DISTANCE FROM STUDY" LIMITED APPROACH BOUNDARY: "INSERT DISTANCE FROM STUDY" FLASH PROTECTION BOUNDARY: "INSERT DESCRIPTION FROM STUDY" PPE CLASS: "INSERT CLASS AND FROM STUDY" INCIDENT ENERGY: "INSERT VALUE E-401 A B DETAIL NOTES: D C FAR R CEILING LINE C DS VERIFY DIM.D B CONTACT MONITOR 9 SCALE: NONE K A (FUTURE) TO ACCESS PANEL (FUTURE) TO FACP (FUTURE) WITH PULL ROPE 2 #18 TSP IN 1/2"C. E-401 (FUTURE) (FUTURE) SIDE OF DOOR COVER ON SECURE 8"X 8"X 4" BOX WITH FUTURE EXTENSION LOCATION FOR COMMON STUBBED TO 1/2" CONDUIT A. AND CTOC STORAGE IN 110 MAPLE. PROVIDE AT DOOR BETWEEN STORAGE ROOM GENERAL NOTES: HEIGHT REQUIREMENTS DETAIL SHOWING MOUNTING FOR CONNECTION. DRILL 3/4" HOLE IN DOOR BUCK, PLATE AND STUB CONDUIT ON SECURE SIDE OF DOOR PRIOR TO ROUGH-IN. COORDINATE EXACT LOCATION OF CONNECTION TO DEVICE PRIOR TO ROUGH-IN. LOCATION ON SECURE SIDE OF DOOR WITH OWNER ACCOMMODATE SENSOR MOUNTING. COORDINATE PROVIDE 2"X 3" BOX MOUNTED AT 90 DEGREES TO REQUEST-TO-EXIT MOTION SENSOR FUTURE LOCATION. FUTURE KEYPAD. COORDINATE WITH OWNER FOR LOCATION. ALL RIGHTS RESERVED ' ENGINEERING & LANDSCAPE ARCHITECTURE, P.C.. SPECIFIC WRITTEN PERMISSION OF SWBR ARCHITECTURE, CORPORATION FOR ANY PURPOSE WHATSOEVER EXCEPT WITH THE THEREOF SHALL BE UTILIZED BY ANY PERSON, FIRM, OR ENGINEERING & LANDSCAPE ARCHITECTURE, P.C. AND NO PART OWNED BY AND REMAIN THE PROPERTY OF SWBR ARCHITECTURE, AND PLANS INDICATED THEREON OR PRESENTED THEREBY ARE THESE DOCUMENTS AND ALL THE IDEAS, ARRANGEMENTS, DESIGNS 387 East Main Street Rochester, NY 14604-2107 Voice: 585.232.8300 Fax: 585.232.9221 w w w . s w b r . c o m FILE PATH:ROCHESTER, N E W Y O R K CONSULTANT PROJECT: CLIENT: DRAWING TITLE proj. no. checked proj. mgr. drawn by STATUS: DRAWING NO. ISSUE DATE:3/26/2014 9:49:24 AMC:\1-Local Revit Models 2014\13465.00_120Maple RTU Replacement_Central_kristins.rvtCORNELL UNIVERSITY REVISIONS no.date by description ENGINEERING P.C. MECHANICAL/ELECTRICAL ENGINEERING CONSULTANTS ROCHESTER, NEW YORK 14604 (585) 288-5590 FAX: (585) 288-0233 M/E Project 130267 150 NORTH CHESTNUT STREET ROCHESTER BUFFALO SYRACUSE CAPITAL DISTRICT JAD 13465.00 CIT RENOVATIONS 06/27/2014 DOCUMENTS 100% CONSTRUCTION E-501 MRG MRG 1 SCALE: NONEE-501 120 MAPLE FIRE ALARM RISER 2 SCALE: NONEE-501 110 MAPLE FIRE ALARM RISER 3 SCALE: NONEE-501 CCC FIRE ALARM RISER (E) BATTERIES TROUBLE TROUBLE IN CASE OF FIRE EVACUATE BUILDING AND CALL THE FIRE DEPARTMENT!!! ALARM 1 ALARM 2 PREALARM TROUBLE PREALARM ALARM 2 ALARM 1 ALARM ALARMALARMALARM ALARM ALARMALARM FACP ALARM TROUBLE TROUBLE ALARM TROUBLE ALARM TROUBLE TROUBLE TROUBLE TROUBLE TROUBLE ALARM TROUBLE ALARM TROUBLE ALARM TROUBLE ALARM TROUBLE ALARM TROUBLE ALARM TROUBLE ALARM TROUBLE ALARM TROUBLE ALARM PREALARM ALARM 2 ALARM 1 ALARM 1 ALARM 2 PREALARM TROUBLE TROUBLETROUBLETROUBLE TROUBLETROUBLE ALARM TROUBLE ALARMALARM TROUBLE TROUBLE TROUBLE ALARM TROUBLE ALARM TROUBLE ALARM TROUBLE ALARM ALARM ALARM (E) FHS FHS FHS ICM ICM DSD DSD RTSRTS FF F F F DH DH DH DH FSD FSD FAR FAR ZONED 4001 SIMPLEX ZONED FCI (E) BATTERIES TROUBLE TROUBLE IN CASE OF FIRE EVACUATE BUILDING AND CALL THE FIRE DEPARTMENT!!! ALARM 1 ALARM 2 PREALARM TROUBLE PREALARM ALARM 2 ALARM 1 ALARM ALARMALARMALARM ALARM ALARMALARM FACP ALARM TROUBLE TROUBLE ALARM TROUBLE ALARM TROUBLE TROUBLE TROUBLE TROUBLE TROUBLE ALARM TROUBLE ALARM TROUBLE ALARM TROUBLE ALARM TROUBLE ALARM TROUBLE ALARM TROUBLE ALARM TROUBLE ALARM TROUBLE ALARM PREALARM ALARM 2 ALARM 1 ALARM 1 ALARM 2 PREALARM TROUBLE TROUBLETROUBLETROUBLE TROUBLETROUBLE ALARM TROUBLE ALARMALARM TROUBLE TROUBLE TROUBLE ALARM TROUBLE ALARM TROUBLE ALARM TROUBLE ALARM ALARM ALARM (E) (E) BATTERIES TROUBLE TROUBLE IN CASE OF FIRE EVACUATE BUILDING AND CALL THE FIRE DEPARTMENT!!! ALARM 1 ALARM 2 PREALARM TROUBLE PREALARM ALARM 2 ALARM 1 ALARM ALARMALARMALARM ALARM ALARMALARM FACP ALARM TROUBLE TROUBLE ALARM TROUBLE ALARM TROUBLE TROUBLE TROUBLE TROUBLE TROUBLE ALARM TROUBLE ALARM TROUBLE ALARM TROUBLE ALARM TROUBLE ALARM TROUBLE ALARM TROUBLE ALARM TROUBLE ALARM TROUBLE ALARM PREALARM ALARM 2 ALARM 1 ALARM 1 ALARM 2 PREALARM TROUBLE TROUBLETROUBLETROUBLE TROUBLETROUBLE ALARM TROUBLE ALARMALARM TROUBLE TROUBLE TROUBLE ALARM TROUBLE ALARM TROUBLE ALARM TROUBLE ALARM ALARM ALARM (E) FIRE ALARM NOTES: J. I. H. G. F. E. D. C. B. A. elevator controller. Addressable monitor devices shall be located adjacent to monitored device. Addressable control devices shall be located within 3 feet of the controlled device, such as ventilation fan or accessible and conspicuous location. Remote Test Stations for Duct Detectors and Beam Detectors: Mount approximately 5 feet high in an 5 feet in height to panel display readout. All panels shall have 36 inches of working clearance in front of panel. Fire Alarm Control Panels, Annunciator Panels, Warden Stations, etc.: Mount in accessible location approximately below ceiling. Audible Notification Appliances: Top of device not less than 90 inches above floor or not less than 6 inches visible to persons entering the floor from the exit stair. appliances in corridors. Locate an appliance opposite each access door to an exit stair so that it will be not more than 15 feet from end of the corridor, with a separation not greater than 100 feet between above the floor. Depending on ceiling height, higher mounting is preferred. Visible appliances shall be located Visual and Combination Audible/Visual Notification Appliances: The entire lens shall be within 80 inches-96 inches detector shall be installed within 2 feet of each sprinkler head. Elevator Shutdown: If sprinkler heads are located in the elevator machine room or hoistway top, one heat elevator recall are only required where the top of the hoistway is sprinklered.) detectors shall be no more than 21 feet from centerline of elevator door. (Hoistway smoke detectors for Elevator Recall: Elevator recall shall be by lobby, machine room, and hoistway smoke detectors only. Lobby not more than 5 feet from door. release. Smoke detectors, which are provided for door release only, shall be on the centerline of doorway and Door Release: Smoke detection providing area coverage on either side of the doors may be used for door conditions and give reasons for coverage design.) (If design conditions other than smooth ceilings or ceiling heights over 12 feet are encountered, show reflected ceiling plan. Provide a spacing of 3 feet or more from supply and return diffusers. Coordinate trades by means of the 0.7 times the detector spacing. Spacing is 30 feet for smoke detectors and 50 feet for heat detectors. Spot Type Heat and Smoke Detectors: For smooth ceilings, all points on the ceiling shall have a detector within and accessible. entrance to an exit. Locate on the latch side of door, if possible. Boxes are to be conspicuous, unobstructed, Manual Fire Alarm Boxes: Mounting height 42-48 inches to handle. Locate no more than 5 feet from the Fire Alarm Mounting and Spacing Guide 10. 9. 8. 7. 6. 5. 4. 3. 2. 1. A. GENERAL NOTES: AREA FOR DURATION OF PROJECT. PROVIDE TEMPORARY HEAT DETECTION FOR ENTIRE CONSTRUCTION ICM IMM AED FF FSD FSD FARFAR FHS FHS FHS ICM ICM DSD DSD RTSRTS FF F F F DH DH DH DH FSD FSD FAR FARICM IMM AED FF FSD FSD FARFAR FHS FHS FHS ICM ICM DSD DSD RTSRTS FF F F F DH DH DH DH FSD FSD FAR FARICM IMM AED FF FSD FSD FARFAR MARKERS". IN CONDUIT CONTAINING MORE THAN ONE WIRE SHALL BE LABELED ON EACH END WITH "E-Z TRANSPOSING OR CHANGING COLOR CODING OF WIRES IS NOT PERMITTED. ALL CONDUCTORS TO ENSURE POSITIVE GROUNDING THROUGHOUT THE ENTIRE SYSTEM. ALL CONDUIT, MOUNTING BOXES AND PANELS SHALL BE HUNG AND FASTENED WITH FITTINGS ANY OTHER FIRE ALARM SYSTEM WIRING IN A COMMON CONDUIT. AND CONTROL WIRING (FAN SHUTDOWN, ETC.) IN SEPARATE CONDUIT. DO NOT RUN WITH ALL LOW VOLTAGE FIRE ALARM CIRCUITS MAY OCCUPY A COMMON CONDUIT. RUN AC POWER PROVIDE ADDITIONAL DETECTORS WHERE REQUIRED. SPACE DETECTORS IN ACCORDANCE WITH THE MANUFACTURERS RECOMMENDED DISTANCE. DIRECTORY. BREAKER SHALL BE CLEARLY MARKED "FIRE ALARM CIRCUIT CONTROL" IN THE PANELBOARD PANELBOARD TO CONTROL PANELS, TERMINAL CABINETS, ETC. AS REQUIRED. THE CIRCUIT PROVIDE 120V, 20A DEDICATED BRANCH CIRCUITS FROM THE LOCAL AREA LIFE SAFETY IDENTIFICATION. TESTING. ALL OTHER FIRE ALARM JUNCTION BOXES SHALL BE MARKED FOR FACP AND OTHER PANELS SHALL BE MOUNTED WITH CLEARANCES FOR OBSERVATION AND WRAP OVER ITSELF, PROTECTING THE WRITING. TAPE. THE TAPE SHALL BE LONG ENOUGH SO WHEN WRAPPED ROUND THE CABLE IT WILL INSTALLATION. LABELING IS TO BE DONE WITH PERMANENT MARKERS ON CLEAR MYLAR RECORD OF THE IDENTIFICATION AND USE OF EACH ABLE MUST BE MADE AT THE TIME OF CABLING MUST BE UNIQUELY IDENTIFIED AND LABELED, AND A PERMANENT, ACCURATE APPLY. ACCORDANCE WITH EQUIPMENT MANUFACTURERS RECOMMENDATIONS AND ALL CODES THAT MAY ALL FIRE ALARM SYSTEM RACEWAY SIZES AND CIRCUITRY REQUIREMENTS SHALL BE IN SPECIFICATION FOR ADDITIONAL FIRE ALARM SYSTEM REQUIREMENTS. ALL WIRING SHALL BE CLASS B WIRING. REFER TO SECTION 283102 OF THE SEE FLOOR PLANS. DEVICES SHOWN ARE DIAGRAMMATICALLY ONLY. FOR EXACT LOCATIONS AND QUANTITIES PROVIDED. NOT ALL EXISTING DEVICES AND EQUIPMENT ARE SHOWN FOR CLARITY OF NEW WORK TO BE REFER TO FLOOR PLANS FOR EQUIPMENT LOCATIONS. SMOKE DETECTORS AND ELEVATOR CONTROLLER, ETC. NOT ALL INTERCONNECTING WIRING IS INDICATED, i.e. AS BETWEEN ELEVATOR LOBBY COMPLETE SYSTEM AS REQUIRED BY SYSTEM MANUFACTURER. TO INDICATE ROUTING OR QUANTITY OF WIRES REQUIRED. PROVIDE WIRING FOR A WIRING INDICATED ON THE RISER DIAGRAM IS DIAGRAMMATIC ONLY. IT IS NOT INTENDED LETTERING INDICATING "FIRE ALARM SYSTEM". ALL FIRE ALARM SYSTEM JUNCTION BOXES SHALL BE PAINTED RED WITH STENCIL AND OPERATIONAL SYSTEM. ADDITIONAL TERMINAL CABINETS, BOOSTERS, ETC. AS REQUIRED TO PROVIDE A COMPLETE DEVICES AND MINIMUM QUANTITIES OF TERMINAL CABINETS & POWER BOOSTERS. PROVIDE THE FIRE ALARM RISER DENOTES THE GENERAL ARRANGEMENT OF THE SYSTEM WITH TYPICAL CIRCUITS. FOR EASY IDENTIFICATION OF INITIATING, INDICATING AND AUXILIARY CONTROL WIRING COLOR CODES SHALL BE CONSISTENT THROUGHOUT THE SYSTEM AND SHALL ALLOW OPENS, OR SHORTS. ALL WIRING SHALL BE CHECKED AND TESTED TO ENSURE THAT THERE ARE NO GROUNDS, DIRECTLY OPPOSITE ITS TERMINAL. CONDUCTORS IN CABINETS SHALL BE FORMED AND HARNESSED SO THAT EACH DROPS OFF S. R. Q. P. O. N. M. L. K. ZONED 7200 FCI 4 SCALE: NONEE-501 120 MAPLE ONE LINE DIAGRAM 900A,3P,MCB(E) 150A,3P 45KVA 175A,3P,MCB150A,3P,MCB T1 70A,3P HP-1 LP-1 350A,3P MDP SERVICE INCOMING IN NAIC SPACE TRANSFORMER FEED TO 225KVA DRAWING NOTES: PROVIDE NEW 150A, 3P CIRCUIT BREAKER IN EXISTING SQUARE D I-LINE PANEL BOARD.1 1 RISER DIAGRAMS FIRE ALARM & POWER (4)#1/0AWG & (1)#6EG IN 2" C. (3)#4AWG & (1)#8EG IN 1.25" C. (4)#2/0AWG & (1)#6EG IN 2" C. ALL RIGHTS RESERVED ' ENGINEERING & LANDSCAPE ARCHITECTURE, P.C.. SPECIFIC WRITTEN PERMISSION OF SWBR ARCHITECTURE, CORPORATION FOR ANY PURPOSE WHATSOEVER EXCEPT WITH THE THEREOF SHALL BE UTILIZED BY ANY PERSON, FIRM, OR ENGINEERING & LANDSCAPE ARCHITECTURE, P.C. AND NO PART OWNED BY AND REMAIN THE PROPERTY OF SWBR ARCHITECTURE, AND PLANS INDICATED THEREON OR PRESENTED THEREBY ARE THESE DOCUMENTS AND ALL THE IDEAS, ARRANGEMENTS, DESIGNS 387 East Main Street Rochester, NY 14604-2107 Voice: 585.232.8300 Fax: 585.232.9221 w w w . s w b r . c o m FILE PATH:ROCHESTER, N E W Y O R K CONSULTANT PROJECT: CLIENT: DRAWING TITLE proj. no. checked proj. mgr. drawn by STATUS: DRAWING NO. ISSUE DATE:3/26/2014 9:49:24 AMC:\1-Local Revit Models 2014\13465.00_120Maple RTU Replacement_Central_kristins.rvtCORNELL UNIVERSITY REVISIONS no.date by description ENGINEERING P.C. MECHANICAL/ELECTRICAL ENGINEERING CONSULTANTS ROCHESTER, NEW YORK 14604 (585) 288-5590 FAX: (585) 288-0233 M/E Project 130267 150 NORTH CHESTNUT STREET ROCHESTER BUFFALO SYRACUSE CAPITAL DISTRICT JAD 13465.00 CIT RENOVATIONS 06/27/2014 DOCUMENTS 100% CONSTRUCTION E-601 MRG MRG SCHEDULES SHEET ELECTRICAL SCHEDULELUMINAIRE TYPE DESCRIPTION AND SIZEFIXTURE LAMP BALLAST VOLTAGE/ RDIFFUSE REFLECTOR/ NUMBER MODEL AND MANUFACTURERAPPROVED NOTES FR1 DOWNLIGHT LED RECESSED ROUND6"LED 120/277V LD6A-10-D010TE-ERM6A10-9-35-6LM1-LI-HB26 MODEL:PORTFOLIO 1 FR2 LUMINAIRE LED RECESSED2’X2’LED 120/277V 22EN-LD1-34-UNV-L835-CD-1-U MODEL:METALUX FR3 LUMINAIRE LED RECESSED2’X4’LED 120/277V 24EN-LD1-6700-UNV-L835-CD1-U MODEL:METALUX FS1 AROUND WRAP INDUSTRIAL1’X4’(2)-28WT5 BALLASTELEC 120/277V VT3-228T5DR-UNV-ER81-CHAIN/SET MODEL:METALUX 1 FS2 LED MOUNTED SURFACE1’X4’LED 120/277V 14EN-LD1-25-UNV-L835-CD1-U MODEL:METALUX 1 EM DIAGNOSTICS SELF WITH PACK BATTERY EMERGENCYLED LED 120/277V APEL-SD MODEL: LITESSURE 1 X1 DIAGNOSTICS SELF WITH BACKUP BATTERY WITH SIGN EXITLED LED 120/277V SLED-B-R-W-SD MODEL:SIMKAR 1 NOTES:GENERAL START PROGRAM BE SHALL BALLAST ALLA. 3500K. BE SHALL LAMPS ALLB. NOTES:REFERENCE COLOR. FOR ARCHITECT WITH COORDINATE1. SCHEDULE CONTROL AND EQUIPMENT ELECTRIC NOTES:GENERAL 1. CONTRACTOR. 26 DIVISION THE BY PROVIDED DEVICESALL 2. NUMBER EQUIPMENT INDICATES NUMBERITEM 3. NOTED. OTHERWISE UNLESS MOUNTED SURFACE BE SHALL DEVICESALL 4. CONTRACTOR. 23 & 22 DIVISION THE BY REQUIRED, AS SIZE OVERLOADS,PROVIDE 5. UNIT. THE AT LOCATED IS DEVICES CONTROL INDICATES"AU" 6. NON-FUSED. INDICATES"NF" 7. UNIT. WITH INTEGRAL INDICATES"IU" EQUIPMENT WIRING & PROTECTION SOURCE,POWER DESIGNATION ITEM BY PLANS THE ON SHOWN AS DEVICESCONTROL ID ITEM NAME LOCATIONROOM HP KW PHASE VOLTS SYSTEM AMPS SYSTEM orMCA CENTER CONTROL orPANEL FUSE FOR "FU"or RBREAKE CIRCUIT UNIT CONTROLTO PANEL FROM WIRINGPOWER EQUIPMENT TO UNITCONTROL FROM WIRINGPOWER STARTER SIZENEMA TYPENEMASTARTER MOTORMANUAL RELAY WITHSTARTER MOTORMANUAL STARTERMAGNETICSTARTER MAGNETICCOMBINATION STARTERVOLTAGE REDUCEDCOMBINATION SIZE (F)MP/FUSE STARTERCOMBINATIONDRIVE SPEEDADJUSTABLE BYPASSWITH DRIVE SPEEDADJUSTABLE ASD REDUNDANTWITH DRIVE SPEEDADJUSTABLEOTHERS BY FURNISHEDUNIT CONTROLPACKAGEDOTHERS BYCONTROLLER PUMPDUPLEX REQUIREDSHUTDOWN FAN ALARMFIRE STATIONTEST REMOTE W/DETECTOR SMOKE DUCTSUPPLY STATIONTEST REMOTE W/DETECTOR SMOKE DUCTRETURN STATIONTEST REMOTE W/DETECTOR SMOKE DUCTEXHAUSTCONNECTIONTHERMOSTAT CONNECTIONAQUASTATCONNECTION DAMPERMOTORIZEDPUSHBUTTONSSTART/STOP SWITCHSELECTORHAND/OFF/AUTOLOCATION DEVICECONTROL SWITCHSAFETY ID ITEM AMPS SWITCH SIZE FUSE LOC. PROOF WEATHER SNOTE REF. PHASE GROUND CONDUIT PHASE GROUND CONDUIT DSS-1 SYSTEM SPLITDUCTLESS MAPLE110 1 208 0.4 PP2 20/2 2#12 1#12 1/2"C 2#12 1#12 1/2"C X 30A NF AU 1,2 DSS-1 DSS-2 SYSTEM SPLITDUCTLESS MAPLE110 1 208 0.4 PP2 20/2 2#12 1#12 1/2"C 2#12 1#12 1/2"C X 30A NF AU 1,2 DSS-2 ACCU-1 UNIT CONDENSING COOLEDAIR MAPLE110 1 208 12.6 PP2 20/2 2#12 1#12 1/2"C 2#12 1#12 1/2"C X 30A NF AU WP 1 ACCU-1 EF-1 FANEXHAUST MAPLE110 0.114 1 120 1.0 PP2 20/1 2#12 1#12 1/2"C 2#12 1#12 1/2"C X 30A NF AU 1 EF-1 2. 1. REFERENCE NOTES: POWER FED FROM OUTDOOR UNIT. PROVIDE NEW CIRCUIT BREAKER IN EXISTING SQUARE D PANEL. SCHEDULEPANELBOARD INFORMATIONPANEL TYPE RATING VOLTAGE RATING BUS RATING AMPERE MAIN SYM) (RMS KAIC MOUNT DEVICES CIRCUIT BRANCH CIRCUITS OF NO.TOTAL NOTES DIST. CIR. BRANCH MLO MCB MFS QUANTITY SIZE-FU FUSE /TRIP POLES NAME LOCATIONROOM VOLT PHASE WIRE F S ACTIVE SPARE SPACE 1 70A 3 30 3 24 20A 1 HP-1 ELEC X 480/277 3 4 150A X 36 6 20A 1 42LP-1 ELEC X 208/120 3 4 175A X SCHEDULE TRANSFORMERDRY-TYPE TRANSFORMER LOCATION THREE RATINGSTRANSFORMER MOUNTING NOTES BLDG.FLOOR ROOM PHASE KVA PRIMARY SECONDARY FLOOR WALL T1 NAIC 1 ELEC X 45 480 208 120/X ALL RIGHTS RESERVED ' ENGINEERING & LANDSCAPE ARCHITECTURE, P.C.. SPECIFIC WRITTEN PERMISSION OF SWBR ARCHITECTURE, CORPORATION FOR ANY PURPOSE WHATSOEVER EXCEPT WITH THE THEREOF SHALL BE UTILIZED BY ANY PERSON, FIRM, OR ENGINEERING & LANDSCAPE ARCHITECTURE, P.C. AND NO PART OWNED BY AND REMAIN THE PROPERTY OF SWBR ARCHITECTURE, AND PLANS INDICATED THEREON OR PRESENTED THEREBY ARE THESE DOCUMENTS AND ALL THE IDEAS, ARRANGEMENTS, DESIGNS 387 East Main Street Rochester, NY 14604-2107 Voice: 585.232.8300 Fax: 585.232.9221 w w w . s w b r . c o m FILE PATH:ROCHESTER, N E W Y O R K CONSULTANT PROJECT: CLIENT: DRAWING TITLE proj. no. checked proj. mgr. drawn by STATUS: DRAWING NO. ISSUE DATE:3/26/2014 9:49:24 AMC:\1-Local Revit Models 2014\13465.00_120Maple RTU Replacement_Central_kristins.rvtCORNELL UNIVERSITY REVISIONS no.date by description ENGINEERING P.C. MECHANICAL/ELECTRICAL ENGINEERING CONSULTANTS ROCHESTER, NEW YORK 14604 (585) 288-5590 FAX: (585) 288-0233 M/E Project 130267 150 NORTH CHESTNUT STREET ROCHESTER BUFFALO SYRACUSE CAPITAL DISTRICT JAD 13465.00 CIT RENOVATIONS 06/27/2014 DOCUMENTS 100% CONSTRUCTION NORTH 0SCALE: 1/4"=1’-0"2’4’8’ 1 PD100 DLT CEF PD-100 (E)" (E)" TYPICAL (E)CA(E)CA(E)CA (E)" (E)CA(E)" (E)CAUP&DN (E)3" RL WALL HOOK (E)ABC FE ON (E)AIR COMPRESSOR (E)G(E)1" (E)1" (E)G EWC UP TO LAVS " HW " CW, " " 1" " HW DN " CW, (E)SAN(E)SAN (E)SAN4" 4" 4" 3" 3" 2" 4" 4" 2" 2" 1" 4" 4" 4" 120 MAPLE 120 MAPLE - PARTIAL FIRST FLOOR PLAN - PLUMBING DEMOLITION PLUMBING DEMOLITION FIRST FLOOR PLAN - 120 MAPLE - PARTIAL DEMOLITION NOTES: 1 2 3 4 5 4 4 4 4 4 4 4 4 3 2 2 1 1 DOMESTIC WATER PIPING BACK TO ACTIVE MAINS AND CAP. DISCONNECT AND REMOVE ALL INACTIVE SANITARY, VENT AND PIPING AND EQUIPMENT. DISSCONNECT AND REMOVE ALL EXISTING COMPRESSED AIR PROVIDE VALVE AND CAP. TRIM AND ALL ASSOCIATED PIPING BACK TO ACTIVE MAINS. DISCONNECT AND REMOVE EXISTING ELECTRIC WATER COOLER, PROVIDE VALVE AND CAP. TRIM AND ALL ASSOCIATED PIPING BACK TO ACTIVE MAINS. DISCONNECT AND REMOVE EXISTING EMERGENCY EYEWASH, AND CAP. ASSOCIATED PIPING BACK TO ACTIVE MAINS. PROVIDE VALVE DISCONNECT AND REMOVE EXISTING SINK, TRIM AND ALL 5 55 5 5 5 132 WOMEN 100TC STAIR 100SE VEST 100CB STAIR 100SD BREAK ROOM 133 LOBBY 100LA CORRIDOR 100CC ROOM CONFERENCE 156 ROOM CONFERENCE 130 ELEV 100EA VEST 100CE ALL RIGHTS RESERVED ' ENGINEERING & LANDSCAPE ARCHITECTURE, P.C.. SPECIFIC WRITTEN PERMISSION OF SWBR ARCHITECTURE, CORPORATION FOR ANY PURPOSE WHATSOEVER EXCEPT WITH THE THEREOF SHALL BE UTILIZED BY ANY PERSON, FIRM, OR ENGINEERING & LANDSCAPE ARCHITECTURE, P.C. AND NO PART OWNED BY AND REMAIN THE PROPERTY OF SWBR ARCHITECTURE, AND PLANS INDICATED THEREON OR PRESENTED THEREBY ARE THESE DOCUMENTS AND ALL THE IDEAS, ARRANGEMENTS, DESIGNS 387 East Main Street Rochester, NY 14604-2107 Voice: 585.232.8300 Fax: 585.232.9221 w w w . s w b r . c o m FILE PATH:ROCHESTER, N E W Y O R K CONSULTANT PROJECT: CLIENT: DRAWING TITLE proj. no. checked proj. mgr. drawn by STATUS: DRAWING NO. ISSUE DATE:3/26/2014 9:49:24 AMC:\1-Local Revit Models 2014\13465.00_120Maple RTU Replacement_Central_kristins.rvtCORNELL UNIVERSITY REVISIONS no.date by description ENGINEERING P.C. MECHANICAL/ELECTRICAL ENGINEERING CONSULTANTS ROCHESTER, NEW YORK 14604 (585) 288-5590 FAX: (585) 288-0233 M/E Project 130267 150 NORTH CHESTNUT STREET ROCHESTER BUFFALO SYRACUSE CAPITAL DISTRICT JAD 13465.00 CIT RENOVATIONS 06/27/2014 DOCUMENTS 100% CONSTRUCTION