Loading...
HomeMy WebLinkAboutMcGraw Hall - Arts QuadNo. Key Plan Issue Date Tel: 607-255-7274 Fax: 607-255-6872 410 Thurston Avenue Commissioner Date Created Project No. Drawn By Checked By CORNELL COUNCIL Ithaca, NY 14850 FOR THE ARTS CORNELL COUNCIL FOR THE ARTS BIENNIAL 2014 "INTIMATE COSMOLOGIES: THE AESTHETICS OF SCALE IN AN AGE OF NANOTECHNOLOGY" KIMSOOJA A NEEDLE WOMAN: GALAXY WAS A MEMORY, EARTH IS A SOUVENIR No. Key Plan Issue Date Tel: 607-255-7274 Fax: 607-255-6872 410 Thurston Avenue Commissioner Date Created Project No. Drawn By Checked By CORNELL COUNCIL Ithaca, NY 14850 FOR THE ARTS 1 SITE PLAN SCALE: 3/128" = 1'-0" Drawing No. S5 SEGMENT 5 SCALE: 1" = 1'-0"S4 SEGMENT 4 SCALE: 1" = 1'-0"S3 SEGMENT 3 SCALE: 1" = 1'-0"S2 SEGMENT 2 SCALE: 1" = 1'-0"S1 SEGMENT 1 SCALE: 1" = 1'-0" No. Key Plan Issue Date Tel: 607-255-7274 Fax: 607-255-6872 410 Thurston Avenue Commissioner Date Created Project No. Drawn By Checked By CORNELL COUNCIL Ithaca, NY 14850 FOR THE ARTS Drawing No. No. Key Plan Issue Date Tel: 607-255-7274 Fax: 607-255-6872 410 Thurston Avenue Commissioner Date Created Project No. Drawn By Checked By CORNELL COUNCIL Ithaca, NY 14850 FOR THE ARTS 5 SITE ASSEMBLY SCALE: 3/8" = 1'-0"4 STRUCTURE ASSEMBLY SCALE: 3/4" = 1'-0" 3 SEGMENT ASSEMBLY SCALE: 1 1/2" = 1'-0" 1 AIR FLOW SCALE: 3/8" = 1'-0" 2 PANEL ASSEMBLY SCALE: 3" = 1'-0" Drawing No. COOL AIR INTAKE WARM AIR VENT 112 111098765432 1'-2 5 32" 1'-2 5 32" 1'-2 5 32" 1'-2 5 32" 1'-2 5 32" 1'-2 5 32" 1'-2 5 32" 1'-2 5 32" 1'-2 5 32" 1'-2 5 32" 1'-2 5 32" 1'-2 5 32" 1'-1 1 32" 3'-615 32" 2'-2" 4'-61 8" ϯϬΣ 1 A-010 1 PLAN SCALE: 3" = 1'-0" No. Key Plan Issue Date Tel: 607-255-7274 Fax: 607-255-6872 410 Thurston Avenue Commissioner Date Created Project No. Drawn By Checked By CORNELL COUNCIL Ithaca, NY 14850 FOR THE ARTS Drawing No. 9'-31 4" 9'-3" 9'-3" 9'-3" 9'-5 3 16" 46'-5 7 16" 9'-3 3 16" 9'-3 3 16" 9'-3 3 16" 9'-53 8" 5'-1113 16" 1'-2 1 16" 1'-1 7/8" TYP. 6'-11 5 16" 3'-53 8" 6'-11 7 16" 2'-313 16" HOR. 1 +1'-2 1/16" HOR. 2 +2'-3 15/16" DOOR +6'-11 7/16" SEG. 1 +9'-3 1/4" SEG. 2 +18'-6 1/4" SEG. 3 +27'-9 1/4" SEG. 4 +37'-0 1/4" CAP +40'-5 5/8" T.O.P. +46'-5 7/16" GRADE +0'-0" 1 SECTION SCALE: 3/16" = 1'-0" No. Key Plan Issue Date Tel: 607-255-7274 Fax: 607-255-6872 410 Thurston Avenue Commissioner Date Created Project No. Drawn By Checked By CORNELL COUNCIL Ithaca, NY 14850 FOR THE ARTS 2 ELEVATION SCALE: 3/16" = 1'-0" Drawing No. 3 16" 3 8" 3 8"3 8" 21 2" 1'-2 5 32" 1 2" 3 8" 3 8" 21 2" 3 8" 11 16" 1 4" 1 1 16"1 2"15 16" 1 SECTION DETAIL SCALE: 6" = 1'-0" 3 PLAN DETAIL SCALE: 6" = 1'-0" 1 8" POLISHED STAINLESS STEEL MIRROR 3 16" POLYMER LAMINATED ACRYLIC PANEL (PMMA) MECHANICALLY FASTENED WATER JET CUT 3 8" X 3 8" STEEL SECTION 3 8" COOL AIR INTAKE GAP FOR STACK EFFECT AT ENTRY DOOR 3 16" POLYMER LAMINATED ACRYLIC PANEL (PMMA) MECHANICALLY FASTENED WATER JET CUT 3 8" X 3 8" STEEL SECTION 21 2" WIDE, 3 8" THICK WATER JET CUT STRUCTURAL STEEL RING VERTICAL AND HORIZONTAL STRUCTURAL MEMBERS SLOTTED AND WELDED AT SEAMS 3 8" DIA. STRUCTURAL BOLTS W/ WASHERS 2 SECTION DETAIL SCALE: 6" = 1'-0" 1 4" PLYWOOD LINING No. Key Plan Issue Date Tel: 607-255-7274 Fax: 607-255-6872 410 Thurston Avenue Commissioner Date Created Project No. Drawn By Checked By CORNELL COUNCIL Ithaca, NY 14850 FOR THE ARTS CONCRETE FOOTING LEVELED WITH C CHANNEL AND GRADE 1 2" X 1" CUT-OUT LIFTING POINT FOR SITE ASSEMBLY 3 8" DIA. STRUCTURAL STEEL BOLT WELDED ON BOTTOM SEGMENT TO BE THREADED AND BOLTED TO UPPER SEGMENT CLEAR SILICONE JOINT AT ALL PLEXIGLASS SEAMS FOR WATERTIGHT CONSTRUCTION 3 8" X 2 1 2" WATER JET CUT STEEL RING PLATE Drawing No. 1 8" POLISHED STAINLESS STEEL MIRROR FLOOR 4'-6 1 16" 4'-4" 4'-6 1 16"4'-1" 21 2" 4'-6 1 16" 11 2" 17 8" 1 2" 1 2" 11 2"3 8" 1 8"1 16" 1 4" S1 AXONOMETRIC SCALE: 1" = 1'-0"S1-4 HOR. STRUCTURAL RING SCALE: 3/4" = 1'-0" 1 CONNECTION SCALE: 6" = 1'-0" S1-3 HOR. STRUCTURAL RING SCALE: 3/4" = 1'-0" S1-1 HOR. STRUCTURAL RING SCALE: 3/4" = 1'-0" 2 DOOR HANDLE SCALE: 6" = 1'-0"3 DOOR HINGE SCALE: 6" = 1'-0" S1-2 HOR. STRUCTURAL RING SCALE: 3/8" = 1'-0" 3 8" DIA. THREADED STRUCTURAL BOLT FOR CONNECTION BETWEEN LARGE SEGMENTS 1 2"X1" CUT-OUT TO PROVIDE LIFTING POINT FOR SITE ASSEMBLY S1-A VERT. STRUCTURAL BAR SCALE: 1" = 1'-0" 3 8" WIDE SLOT TO MEET CORRESPONDING SLOTS IN HORIZONTAL STRUCTURAL RINGS 1 2"X1" CUT-OUT TO PROVIDE LIFTING POINT FOR SITE ASSEMBLY No. Key Plan Issue Date Tel: 607-255-7274 Fax: 607-255-6872 410 Thurston Avenue Commissioner Date Created Project No. Drawn By Checked By CORNELL COUNCIL Ithaca, NY 14850 FOR THE ARTS Drawing No. 4'-4 7 16" 4'-6 1 16" 4'-23 4" 4'-1 1 16"3'-6 5 16" 3'-8" 3'-113 8" 3'-911 16" 3'-45 8" S2 AXONOMETRIC SCALE: 1" = 1'-0" 1 CONNECTION SCALE: 6" = 1'-0" 3 8" DIA. THREADED STRUCTURAL BOLT FOR CONNECTION BETWEEN LARGE SEGMENTS 1 2"X1" CUT-OUT TO PROVIDE LIFTING POINT FOR SITE ASSEMBLY 3 8" WIDE SLOT TO MEET CORRESPONDING SLOTS IN HORIZONTAL STRUCTURAL RINGS 1 2"X1" CUT-OUT TO PROVIDE LIFTING POINT FOR SITE ASSEMBLY S2-4 HOR. STRUCTURAL RING SCALE: 3/4" = 1'-0" S2-3 HOR. STRUCTURAL RING SCALE: 3/4" = 1'-0" S2-1 HOR. STRUCTURAL RING SCALE: 3/4" = 1'-0" S2-2 HOR. STRUCTURAL RING SCALE: 3/4" = 1'-0" S2-A VERT. STRUCTURAL BAR SCALE: 1" = 1'-0"S2-8 HOR. STRUCTURAL RING SCALE: SCALE: 3/4" = 1'-0" S2-7 HOR. STRUCTURAL RING SCALE: 3/4" = 1'-0" S2-5 HOR. STRUCTURAL RING SCALE: 3/4" = 1'-0" S2-6 HOR. STRUCTURAL RING SCALE: 3/4" = 1'-0" S2-9 HOR. STRUCTURAL RING SCALE: 3/4" = 1'-0" No. Key Plan Issue Date Tel: 607-255-7274 Fax: 607-255-6872 410 Thurston Avenue Commissioner Date Created Project No. Drawn By Checked By CORNELL COUNCIL Ithaca, NY 14850 FOR THE ARTS Drawing No. 2'-3 3 16" 2'-81 4" 2'-915 16" 2'-6 9 16" 2'-47 8"2'-11 9 16" 3'-11 4" 3'-45 8" 3'-215 16" S3 AXONOMETRIC SCALE: 1" = 1'-0" 1 CONNECTION SCALE: 6" = 1'-0" 3 8" DIA. THREADED STRUCTURAL BOLT FOR CONNECTION BETWEEN LARGE SEGMENTS 1 2"X1" CUT-OUT TO PROVIDE LIFTING POINT FOR SITE ASSEMBLY 3 8" WIDE SLOT TO MEET CORRESPONDING SLOTS IN HORIZONTAL STRUCTURAL RINGS 1 2"X1" CUT-OUT TO PROVIDE LIFTING POINT FOR SITE ASSEMBLY S3-4 HOR. STRUCTURAL RING SCALE: 3/4" = 1'-0" S3-3 HOR. STRUCTURAL RING SCALE: 3/4" = 1'-0" S3-1 HOR. STRUCTURAL RING SCALE: 3/4" = 1'-0" S3-2 HOR. STRUCTURAL RING SCALE: 3/4" = 1'-0" S3-A VERT. STRUCTURAL BAR SCALE: 1" = 1'-0"S3-8 HOR. STRUCTURAL RING SCALE: 3/4" = 1'-0" S3-7 HOR. STRUCTURAL RING SCALE: 3/4" = 1'-0" S3-5 HOR. STRUCTURAL RING SCALE: 3/4" = 1'-0" S3-6 HOR. STRUCTURAL RING SCALE: 3/4" = 1'-0" S3-9 HOR. STRUCTURAL RING SCALE: 3/4" = 1'-0" No. Key Plan Issue Date Tel: 607-255-7274 Fax: 607-255-6872 410 Thurston Avenue Commissioner Date Created Project No. Drawn By Checked By CORNELL COUNCIL Ithaca, NY 14850 FOR THE ARTS Drawing No. 2'-11 2" 2'-3 3 16" 1'-1113 16" 1'-101 8"1'-33 8" 1'-5 1 16" 1'-8 7 16" 1'-63 4" 1'-111 16" S4 AXONOMETRIC SCALE: 1" = 1'-0" 1 CONNECTION SCALE: 6" = 1'-0" 3 8" DIA. THREADED STRUCTURAL BOLT FOR CONNECTION BETWEEN LARGE SEGMENTS 3 8" WIDE SLOT TO MEET CORRESPONDING SLOTS IN HORIZONTAL STRUCTURAL RINGS 1 2"X1" CUT-OUT TO PROVIDE LIFTING POINT FOR SITE ASSEMBLY S4-4 HOR. STRUCTURAL RING SCALE: 3/4" = 1'-0" S4-3 HOR. STRUCTURAL RING SCALE: 3/4" = 1'-0" S4-1 HOR. STRUCTURAL RING SCALE: 3/4" = 1'-0" S4-2 Horizontal Structural Rings SCALE: 3/4" = 1'-0" S4-A VERT. STRUCTURAL BAR SCALE: 1" = 1'-0"S4-8 HOR. STRUCTURAL RING SCALE: 3/4" = 1'-0" S4-7 HOR. STRUCTURAL RING SCALE: 3/4" = 1'-0" S4-5 HOR. STRUCTURAL RING SCALE: 3/4" = 1'-0" S4-6 HOR. STRUCTURAL RING SCALE: 3/4" = 1'-0" S4-9 HOR. STRUCTURAL RING SCALE: 3/4" = 1'-0" No. Key Plan Issue Date Tel: 607-255-7274 Fax: 607-255-6872 410 Thurston Avenue Commissioner Date Created Project No. Drawn By Checked By CORNELL COUNCIL Ithaca, NY 14850 FOR THE ARTS Drawing No. 11 2" 1" 1'-17 8" 4'-8 1 32" 419 32" 3" 321 32" 21 2" 1 2" 811 16" 10 5 16" 1'-111 16" 1' 613 16" 7" S5 AXONOMETRIC SCALE: 1" = 1'-0" 1 CAP SECTION SCALE: 3" = 1'-0"2 CAP DETAIL SCALE: 1" = 1'-0" 1 1 2" WARM AIR OUTLET FOR STACK EFFECT 1 16" CONICALLY ROLLED SHEET METAL WITH INTERIOR VERTICAL SUPPORTS 3 8" WIDE SLOT TO MEET CORRESPONDING SLOTS IN HORIZONTAL STRUCTURAL RINGS S5-3 HOR. STRUCTURAL RING SCALE: 3/4" = 1'-0" S5-2 HOR. STRUCTURAL RING SCALE: 3/4" = 1'-0" S5-1 HOR. STRUCTURAL RING SCALE: 3/4" = 1'-0" S5-A VERT. STRUCTURAL BAR SCALE: 1" = 1'-0"S5-4 HOR. STRUCTURAL RING SCALE: 3/4" = 1'-0" S5-5 CAP HOR. STRUCTURAL RING SCALE: 3/4" = 1'-0" S5-6 CAP HOR. STRUCTURAL RING SCALE: 3/4" = 1'-0" No. Key Plan Issue Date Tel: 607-255-7274 Fax: 607-255-6872 410 Thurston Avenue Commissioner Date Created Project No. Drawn By Checked By CORNELL COUNCIL Ithaca, NY 14850 FOR THE ARTS Drawing No. 6 5 4 12 0 4" SEED OR HYDROSEED - AS SPECIFIED. S W MULCH - STALKS FRO OATS,WHEAT AND/OR RYE FREE FROM SEED AND WEED SEED TOPSOIL MIX AS SPECIFIED - 4" AFTER COMPACTION UNDISTURBED AND/OR COMPACTED EARTH BACK FILL AS SPECIFIED - 2/3 EXISTING SOIL MIXED WITH 1/3 NEW ORGANIC ' TERIAL. NOTE: FERTILIZER ADDED PER SPECIFICATION SCALE: NONE STRUCTURAL DESIGN CRITERIA NOTE: ALL LOADS SHALL BE DETERMINED IN ACCORDANCE WITH THE "BUILDING CODE OF NEW YORK", LATEST EDITION TYPE CODE REFERENCE DESCRIPTION DESIGN CRITERIA BUILDING DATA LOCATION CORNELL UNIVERSITY, ITHACA, NEW YORK C PTER 31, STRUCTURE TEMPORARY STRUCTURE NON PERMIT REQUIRED TEMPORARY STRUCTURE WITH AREA OF 20 SF SEISMIC LOAD REPAIR LAWN AREAS AS REQUIRED PER DETAIL EXISTING LAWN 3 " COMPACTED NYSDOT TYPE 6 F TOP (1/4" PER 1ft CROSS PITCH) UNDISTURBED OR COMPACTED SUB -GRADE WIND LOAD BCNYS TABLE 1613.5.5 SOIL SITE CLASS D BCNYS SECTION 1613.5.4 SHORT -PERIOD SPECT RESPONSE COEFFICIENT Sos) 0.170g BCNYS SECTION 1613.5.4 1 -SEC. PERIOD SPECTRAL RESPONSE COEFFICIENT (Sot) 0.089g BCNYS TABLE 1613.5.6 (1&2) BCNYS SEISMIC DESIGN CATEGORY BASIC WIND SPEED - 3 SECOND GUST B 90 MPH WIND IMPORTANCE FACTOR EXPOSURE CATEGORY 1.0 B STRUCTURAL DESIGN CRITERIA SCALE: NOTES: 1.0 TAMP EDGES OF WALK DURING INSTALLATION. 2.0 WALK WIDTH SHALL BE AS SPECIFIED ON PLAN. SCALE: (12) -112" 0 A325 BOLTS WI WASHERS AND DOUBLE NUT MIRROR FLOOR BY ARTIST CONCRETE FILL INSIDE C NEL LEAVE 3/4" FOR LEVEL GROUT ANDMIRROR C12x20.7 ROLLED CIRCLE, OUTSIDE 0 OF 4'-7"+/-, FULL BUTT LD FLUSH AT THRESHOLD ASPHALT SLOPE, 2% (12) - 314"0 HILTI IK BOLT TZ -CS EQUAL SPACE AROUND CHANNEL W/ 4 3/4" MINIMUM EMBEDMENT LOCATION P N CONCRETE NOTES CONTINUED: 3.0 PROVIDE CONCRETE COVER OVER REINFORCING IN ACCORDANCE WITH THE REQUIREMENTS OF ACI 318. 4.0 MATERIALS 4.1 CURING MATERIALS: 4.1.1 ABSORPTIVE COVER: AASHTO M 182, CLASS 2, BURLAP CLOTH MADE FROM JUTE OR KENAF, WEIGHING APPROXIMATELY 9 OZ./SQ. YD. WHEN DRY. 4.1.2 WATER: POTABLE. 5.0 CONCRETE PLACEMENT 5.1 BEFORE PLACING CONCRETE, VERIFY THAT INSTALLATION OF FORMWORK, REINFORCEMENT, AND EMBEDDED ITEMS IS COMPLETE AND THAT REQUIRED INSPECTIONS HAVE BEEN PERFORMED. 5.2 DEPOSIT CONCRETE CONTINUOUSLY IN ONE LAYER OR IN HORIZONTAL LAYERS OF SUCH THICKNESS THAT NO NEW CONCRETE WILL BE PLACED ON CONCRETE THAT HAS HARDENED ENOUGH TO CAUSE SEAMS OR PLANES OF WEAKNESS. IF A SECTION CANNOT BE PLACED CONTINUOUSLY, PROVIDE CONSTRUCTION JOINTS BASED ON THE ENGINEERS RECOMMENDATIONS. DEPOSIT CONCRETE TO AVOID SEGREGATION. 5.3 CONSOLIDATE PLACED CONCRETE WITH MECHANICAL VIB TING EQUIPMENT ACCORDING TO ACI 301. 5.4 COLD -WEATHER PLACEMENT: COMPLY WITH ACI 306.1. 5.5 HOT -WEATHER PLACEMENT: COMPLY WITH ACI 301. 6.0 FINISHING SLABS 6.1 GENERAL: COMPLY WITH ACI 302.1R RECOMMENDATIONS FOR SCREEDING, RESTRAIGHTENING, AND FINISHING OPERATIONS FOR CONCRETE SURFACES. DO NOT WET CONCRETE SURFACES. 7.0 CONCRETE PROTECTING AND CURING 7.1 GENERAL: PROTECT FRESHLY PLACED CONCRETE FROM PREMATURE DRYING AND EXCESSIVE COLD OR HOT TEMPERATURES. 7.2 CURE CONCRETE ACCORDING TO ACI 308.1, BY MOISTURE CURING. KEEP SURFACES CONTINUOUSLY MOIST FOR NOT LESS THAN SEVEN DAYS. 7.3 SATURATE THE SURFACE OF ALL EXISTING ADJACENT CONCRETE. STRUCTURAL STEEL NOTES: .0 STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING: 1.1 CHANNELS ........ ........ ........... ............. ....... ..... ......_......_.ASTM A36 1.2 HIGH-STRENGTH BOLTS............................................ASTM A325 2.0 ALL STRUCTURAL STEEL SHALL BE DETAILED, FABRICATED AND ERECTED IN STRICT ACCORDANCE WITH THE LATEST A.I.S.C. SPECIFICATIONS. .0 ALL STRUCTURAL STEEL IS TO RECEIVE ONE SHOP COAT OF FABRICATOR'S STANDARD RUST -INHIBITING PRIMER. 4.0 ALL WELDS SHALL BE MADE IN ACCORDANCE WITH THE LATEST REQUIREMENTS OF THE AWS, USING E70 ELECTRODES. 0 CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR REVIEW . SCOPE OF WORK/SEQUENCE OF WORK: 1.0 BEFORE THE EXHIBIT OPENING IN MID SEPTEMBER, 2014: 1.1 INSTALL FOUNDATION AND CHANNEL SUPPORT FOR THE SCULPTURE ACCORDING TO THE CONSTRUCTION DOCUMENTS. 1.2 FIELD DRILL BOLT HOLES IN TOP FLANGE OF CHANNEL TO ATTACH SCULPTURE IN COORDINATION WITH SCULPTURE BASE PLATE ANCHOR BOLT LAYOUT. 1.3 INSTALL PATH TO THE SCULPTURE UP TO THE TOP OF THE SUB BASE MATERIAL. 1.4 INSTALUERECT THE 45 FOOT TALL, 4'-6" DIAMETER SCULPTURE WHICH WILL BE DELIVERED TO CENTRAL AVENUE, ADJACENT TO THE ARTS QUAD BOLT SCULPTURE TO TOP FLANGE OF C12. 1.4.1 STRUCTURE INFORMATION: 1.4.1.1 APPROXIMATE WEIGHT OF THE STRUCTURE IS 5000 POUNDS. 1.4.1.2 THE OVERALL STRUCTURE IS 45 FEET TALL. THE STRUCTURE IS DIVIDED INTO 5 SEGMENTS THAT ARE APPROXIMATELY 9 FEET IN LENGTH. THE CONTRACTOR WILL BE RESPONSIBLE FOR BOLTING THE SEGMENTS TOGETHER. THEIR RESPECTIVE WEIGHTS ARE: +/-1500 lbs (FIRST BOTTOM SEGMENT), +/- 1200 Ibs, +/- 1000 Ibs, +/- 900 Ibs, +/- 300 lbs (TOP SEGMENT). 1.4.1.3 EACH SEGMENT WILL HAVE LIFTING POINTS DESIGNED ALONG THE VERTICAL STRUCTU MEMBERS. THE LIFTING POINTS WILL BE CIRCULAR CUT-OUTS WITH A DIA. OF 1/2" 1.5 INSTALL 3" LIGHT DUTY ASPHALT TOP PATH TO THE SCULPTURE PER 5/S-101. 1.6 RESTORE SITE TO ORIGINAL CONDITIONS, SEED AND WATER. 2.0 AT THE END OF THE EXHIBIT IN MID DECEMBER, 2014: 2.1 UNINSTALL THE SCULPTURE AND LOAD ON TRUCK ON CENTRAL AVENUE, ADJACENT TO THE ARTS QUAD. SALVAGE THE ROLLED C12x20.7 AND TURN OVER TO CORNELL. 2.2 REMOVE AND DISPOSE OF THE FOUNDATION AND ASSOCIATED COMPONENTS. 2.3 REMOVE AND DISPOSE OF ASPHALT PAVEMENTS. 2.4 RESTORE SITE TO ORIGINAL CONDITION AND SEED PER 6/S-101. GENERAL NOTES: 1.0 ALL STRUCTURAL WORK, INCLUDING MATERIAL STRESSES AND METHODS OF CONSTRUCTION SHALL CONFORM TO THE BUILDING CODE OF THE STATE OF NEW YORK, LATEST EDITION AND ALL OTHER APPLICABLE LOCAL CODES. 2.0 DIMENSIONS AND ELEVATIONS SHOWN ON PLAN AS PLUS/MINUS (+/-) ARE TO BE CONSIDERED APPROXI ' ATE. EXACT VALUES FOR ALL (+/-) DIMENSIONS ARE TO BE DETERMINED BY THE GENERAL CONTRACTOR IN THE FIELD THROUGH A BUILDING LAYOUT. THE CONTRACTOR SHALL VERIFY EXISTING DIMENSIONS, ELEVATIONS AND CONDITIONS AND NOTIFY THE ENGINEER OF ANY DISCREPANCIES PRIOR TO COMMENCING WORK. NING: IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT HIS SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS SIGNATURE, THE ATE OF SUCH AL I tRATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. ARCH: CIVIL- ELEC: MECH- REVISIONS: DATE: 6/6/2014 - ISSUE FOR CONSTRUCTION 3.0 CONTRACTOR SHALL LOCATE ALL UNDERGROUND UTILITIES IN VICINITY OF FOUNDATIONS AND NOTIFY THE ARCHI I ECT IF A CONFLICT EXISTS. PROVIDE INFORMATION ON LOCATION SIZE AND ELEVATION OF UTILITIES PRIOR TO START OF WORK SO THAT ANY NECESSARY CHANGES CAN BE MADE WITHOUT DELAYING THE PROJECT SCHEDULE. NOTES j DEMOLITION NOTES: SCALE: 1/2"=1 4'-6"+/_ COORDINATE W/SCULPTURE y 10'-7 1/2"+ 1.0 PROVIDE ADEQUATE MEASURES TO PROTECT WORKS AND THE GENERAL PUBLIC DURING THE SHORING, DEMOLITION AND CONSTRUCTION PHASE OF THE PROJECT. EARTHWORK AND FOUNDATION NOTES: 1.0 ALL FOOTINGS ARE TO BE PLACED ON CLEAN, DRY, LEVEL, UNDISTURBED NATIVE SOIL, ON IMPORTED, SELECT STRUCTURAL FILL, OR LEAN CONCRETE THAT HAS BEEN INSPECTED AND APPROVED BY THE PROJECT ENGINEER. THE SUITABILITY AND STABILITY OF EXISTING SOILS, THE DEPTHS AND LATERAL LIMITS OF UNSUITABLE MATERIAL TO BE REMOVED, AND ADEQUACY OF FOUNDATION BEARING GRADES SHALL BE DETERMINED BY THE PROJECT ENGINEER. FOUNDATIONS SHALL NOT BE PLACED IN WATER, ON FROZEN GROUND OR EXPOSED TO WEATHER. 2.0 IF GROUNDWATER IS ENCOUNTERED DURING EARTHWORK, FOUNDATION BEARING GRADES SHALL BE UNDERCUT APPROXIMATELY 6 INCHES, AND REPLACED WITH SELECT IMPORTED STRUCTURAL FILL. PRIOR TO PLACING THE FILL, A WOVEN GEOTEXTILE FABRIC (MIRAFI 500X OR APPROVED EQUAL) SHALL BE PLACED UPON THE APPROVED BEARING GRADE. THE GEOTEXTILE SHALL BE W "PED OVER THE TOP OF THE STRUCTURAL FILL. THE SELECT IMPORTED STRUCTURAL FILL SHALL EXTEND A MINIMUM LATERAL DISTANCE FROM THE EDGE OF THE FOUNDATION OF 6 INCHES. CONCRETE FILL INSIDE CHANNEL LEAVE 3/4" FOR LEVEL GROUT AND MIRROR (12) - 1/2" 0 A325 BOLTS W/WASHERS AND DOUBLE NUT GRADE SLOPES AWAY, 2% 99" x 9'-9" x 2'-1000NCRETE FOUNDATION "GALAXY IS A MEMORY, EARTH IS A SOUVENIR". SCULPTURE BfST- C12x20.7 ROLLED CIRCLE, OUTSIDE 0 OF 4'-7"+/-, FULL BUTT WELD LIGHT DUTY ASPHALT \, PAVEMENT 3.0 ALL EXCAVATIONS SHALL FULLY CONFORM TO ALL LOCAL, STATE AND FEDERAL SAFETY REGULATIONS. z s A E 0 4.0 ALL FORMS AND REINFORCING STEEL IN PLACE SHALL BE APPROVED BY E OWNER'S REPRESENTATIVE BEFORE ANY CONCRETE IS PLACED. SCULPTURE DOOR OPENING, COORDINATE W/ SCULPTURE DIMENSIONS (12) - 3/400 HILTI IK BOLT TZ -CS EQUAL SPACE AROUND CHANNEL W/ 4 3/4" MINIMUM EMBEDMENT CONCRETE NOTES: DATE: June 6, 2014 1.0 ALL CONCRETE WORK, CONSTRUCTION, AND REINFORCING DETAILS SHALL CONFORM TO THE BUILDING CODE OF NEW YORK STATE AND "THE MANUAL OF STANDARD PRACTICE" (ACI -301), LATEST EDITION. FACILITY: 5920, 2500 DESIGN: ERIK ESHEL 2.0 THE CONCRETE MIX SHALL MEET THE FOLLOWING MINIMUM CRITERIA: 2.1 MINIMUM CONCRETE COMPRESSIVE STRENGTH SHALL BE 4500 PSI AT 28 DAYS. 2.2 THE WATER CEMENT RATIO SHALL BE NO GREATER THAN 0.45. 2.3 THE AIR CONTENT SHALL BE 6.0% +1- 1.0% 2.4 CONTRACTOR SHALL SUBMIT MIX DESIGN FOR REVIEW AND APPROVAL BY ENGINEER. SITE PLAN, SECTIONS, DETAILS AND NOTES SCALE: 1/2"=1'-0" :10 1/2" = 1'-0" NOTES Sheet 1 of 1 S 101 P0465 6 15 14 12 10