Loading...
HomeMy WebLinkAboutHollister HallCB CB CB CB CB CB CB CB CB CB CB CB CB CB CB CB CB CB CB CB CB CB CB CB CB CB CB CB CB CB CB CB CB CB CB CB CB CB 191920202021212121202020201919 191920202021212121202020201919 191920202021212121202020201919 191920202021212121202020201919 191920202021212121202020201919 19 19 21 2020 2020 21 21212121212121 2121 212121 2121 PAVED PARKING UNPAVED PARKING UNPAVED PARKING SS S FP SIG N B52 2B00SA2B00EB 2B00SC 2B00SB B00CB B08 B00SB B00UF B00UG B03A B03B B03 B20 B14 B00UB B00UA B00TB B00SA B21 2BM0U B28 B00E B00TA B00JC B52CB52B B00CA B00UC B55 B60A B63 B00JB B30 B62 B60B B56A B62A B54 B56 B60B52A B00UE B64 B66 3207 752 88 163 253 630 1151 1020 655 226 2221 128 463 131 187 360 337 88 44 113 127 2637 2145 402 238 509 257 36 92 43 107 251 34 543 789 2140 21 764 173 230 2B20 OPEN TO BELOW OPEN TO BELOW SHIPS LADDER DN DN DN DN UP DN UP UP DN HOLLISTER HALL CAMPUS ROAD COLLEGE AVENUEHOY ROADEAST AVENUESAGE AVENUEAREA OF WORK CORNE LL U N I V E RSI TYFOUN D E D 5681AD CORNE LL U N I V E RSI TYFOUN D E D 5681 AD FACILITIES ENGINEERING N ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 Cornell University HOLLISTER HALL Hollister Hall B55, B60, B60A, B60B, B63, B64 Lab Renovations A-001 12025236 TITLE SHEET FE DESIGN RLH 2046 OCTOBER 31, 2019 Hollister Hall B55, B60, B60A, B60B, B63, B64 Lab Renovations 1 10/31/19 ISSUE FOR PERMIT ARCHITECTURAL A-001 TITLE SHEET A-101 CODE EGRESS PLAN & GENERAL NOTES A-102 PARTIAL - BASEMENT DEMOLITION PLAN A-103 RENOVATION - BASEMENT FLOOR PLAN A-401 PARTIAL BASEMENT REFLECTED / STRUCTURAL FRAMING CEILING PLAN MECHANICAL M-001 GENERAL NOTES AND SYMBOL LEGENDS M-101 BASEMENT MECHANICAL HVAC CONSTRUCTION PLAN M-102 BASEMENT MECHANICAL PIPING PLAN M-301 CONTROLS M-401 MECHANICAL DETAILS M-501 MECHANICAL SCHEDULES MD-101 BASEMENT MECHANICAL HVAC & PIPING DEMOLITION PLAN ELECTRICAL E-001 GENERAL NOTES AND SYMBOL LEGENDS E-101 BASEMENT - ELECTRICAL DEMOLITION PLAN E-102 ELECTRICAL NEW WORK PLANS BUILDING CODE SUMMARY APPLICABLE CODES 2015 (EXISTING) IBC (ADOPTED BY NEW YORK STATE)WITH NEW YORK STATE AMENDMENT. PROJECT SUMMARY THIS PROJECT INCLUDES THE RENOVATION OF APPROXIMATELY 3,000 SF OF LAB SPACE THE WORK IS ALTERATION LEVEL 2 AND IS WITHIN THE CITY OF ITHACA JURISDICATION. BUILDING LIMITATIONS CONSTRUCTION CLASSIFICATION:IIB CLASSIFICATION OF HAZARDS:NONE HIGH-RISE BUILDING:NO EXTINGUISHING REQUIREMENT:THE EXISTING BUILDING IS NOT SPRINKLERED OCCUPANCY OCCUPANCY CLASSIFICATION:BUSINESS (B) GENERAL SYMBOLS LEGEND EXTERIOR ELEVATION 1 1 1 1X-100 X-100 1 1 1 1 INTERIOR ELEVATION 1 X-100 SECTION MARKER 1 X-100 ENLARGED DETAIL CONSTRUCTION KEYED NOTE DEMOLITION KEYED NOTE DRAWING REVISION NOTE# DRAWING INDEX LINETYPE: TO BE PROVIDED / NEW LINETYPE: DEMOLITION / TO BE RELOCATED LINETYPE: EXISTING TO REMAIN PROJECT SCOPE The purpose of this project is to renovate the lab rooms by painting existing metal casework countertops, asbestos abatement of flooring, removal of existing CMU walls, removal of doors / door frames, installing of new metal stud/gypsum wall board walls, ADA compliant sink/casework and ADA compliant door. PERSPECTIVE VIEW # # SITE LOCATION -HOLLISTER HALL AREA OF WORK PLAN AREA OF WORK TRAVEL 68' EXIT TRAVEL68' EXITTRAVEL68' EXITTRAVEL 68' EXIT TRAVEL68' EXITLEGEND PATH OF EGRESS EXISTING 1 HR FIRE RESISTANCE RATED CONSTRUCTION TRAVEL 68' EXIT TRAVEL 108' EXIT TRAVEL 108' EXIT TRAVEL108' EXITADA WORKSTATION ADA WORKSTATION ADA WORKSTATION ADA SINK W/ EYEWASH NON-CLASS LABORATORY SERVICE B64 MECHANICAL B66 MACHINE SHOP B56 OFFICE B56A CLASS LABORATORY WET B60 DATA PROCESSING COMPUTER B55UTILITY AREA B00UC CORRIDOR B00CA A &AND @ AT ACT ACOUSTICAL CEILING TILE ALT ALTERNATE ALUM ALUMINUM AVG AVERAGE AFF ABOVE FINISH FLOOR B BD BOARD BLDG BUILDING BOD BOTTOM OF DECK BSMT BASEMENT C CG CORNER GUARDS CJ CONTROL JOINT CLG CEILING CL CENTER LINE CLR CLEAR CMU CONCRETE MASONRY UNIT COL COLUMN CONC CONCRETE CONF CONFERENCE CONT CONTINUOUS CORR CORRIDOR CPT CARPET CRS COURSE(S) CT CERAMIC TILE D DEMO DEMOLITION DF DRINKING FOUNTAIN DIA DIAMETER DIM DIMENSION DN DOWN DO DOOR OPENING DWG DRAWING E EA EACH EJ EXPANSION JOINT ELEC ELECTRIC ELEV ELEVATION/ ELEVATOR EPDM RUBBER ROOF MEMBRANE EQ EQUAL EX'G EXISTING EXT EXTERIOR F FD FLOOR DRAIN FDN FOUNDATION FEC FIRE EXTINGUISHER CABINET FFE FINISH FLOOR ELEVATION FRP FIBER REINFORCED POLYESTER FT FOOT/FEET FTG FOOTING G GA GAGE GALV GALVANIZED GC GENERAL CONTRACTOR GEN GENERAL GL GLASS GWB GYPSUM WALL BOARD H HC HANDICAPPED HT HEIGHT HM HOLLOW METAL HR HOUR HVAC HEATING, VENTILATING & AC J JAN JANITOR L LAV LAVATORY LB/#POUND LGMF LIGHT GAGE METAL FRAMING M MFR MANUFACTURER MAT MATERIAL MAX MAXIMUM MEZZ MEZZANINE MIN MINIMUM MO MASONRY OPENING MTL METAL N NA NOT APPLICABLE NIC NOT IN CONTRACT NR NOT RATED NTS NOT TO SCALE O OC ON CENTER OD OUTSIDE DIAMETER OPNG OPENING OSB ORIENTER STRAND BOARD P +/-PLUS OR MINUS PSF POUNDS PER SQUARE FOOT PSI POUNDS PER SQUARE INCH PT PRESSURE TREATED Q QTY QUANTITY R R RISER RD ROOF DRAIN REF REFRIGERATOR REQ REQUIRED REV REVISION RO ROUGH OPENING RTU ROOF TOP UNIT S SHTG SHEATHING SIM SIMILAR SF SQUARE FOOT/ FEET SS STAINLESS STEEL STL STEEL STD STANDARD T T TREAD T&G TONGUE & GROOVE TEL TELEPHONE TEMP TEMPERATURE TOS TOP OF STEEL TV TELEVISION TYP TYPICAL U UEV UNEVEN DOORS W/ VISION PANEL UEF UNEVEN FLUSH DOOR V VCT VINYL COMPOSITION TILE VIF VERIFY IN FIELD W W/O WITHOUT WD WOOD ABBREVIATIONS 101 A101 1 1 1 1 0 Name Elevation 101 X-X X 1t DN WALL -EXISTING WALL -METAL STUD/ GWB WALL -CONCRETE WALL -CMU WALL -BRICK ITEMS FOR DEMOLITION DOOR/ WALL -EXISTING DOOR/ WALL -NEW DOOR/ WALL -DEMOLITION TAG -DOOR TAG -WINDOW TAG -WALL TAG -ROOM # CENTER LINE PHOTO REFERENCE LEVEL MARKER COLUMN GRID MARKER ELEVATION MARKER ELEVATION CHANGE ARROWS BREAK LINE SYMBOLS 0' -0"CORNE LL U N I V E RSI TYFOUN D E D 5681 AD FACILITIES ENGINEERING N ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 HOLLISTER HALL Hollister Hall B55, B60, B60A, B60B, B63, B64 Lab Renovations A-101 12025236 CODE EGRESS PLAN & GENERAL NOTES RLH R. HERKO 2046 OCTOBER 31, 2019 SCALE:1/8" = 1'-0"1 BASEMENT - CODE PLAN SCOPE OF WORK 1.0 REMOVE EXISTING WALLS AND DOORS AS INDICATED 2.0 INSTALL NEW METAL STUD & GYP. WALL BOARD PARTITIONS AS INDICATED. 3.0 INSTALL NEW ADA COMPLIANT SINK / CASEWORK AS INDICATED. 4.0 INSTALL FINISHES AS INDICATED 5.0 INSTALL NEW DOOR & FRAMES AS INDICATED GENERAL NOTES 1.0 DESIGN, CONSTRUCTION AND SAFETY SHALL CONFORM TO ALL LOCAL, STATE AND OWNER SPECIFIC CODES, INCLUDING (BUT NOT LIMITED TO) THE NEW YORK STATE UNIFORM FIRE PROTECTION AND BUILDING CODE, LATEST REVISION, THE NFPA 101 LIFE SAFETY CODE, LATEST REVISION, ANSI A117.1 - LATEST REVISION, OSHA, AND ANY OTHER CODES GOVERNED BY THE JURISDICTION IN WHICH THIS PROJECT IS BEING CONSTRUCTED. 2.0 THIS CONTRACT REQUIRES COMPLETE, FINISHED WORKABLE PROJECT OF THE AREAS INDICATED BY THE CONTRACT DOCUMENTS, AND SHALL INCLUDE ALL MATERIALS AND LABOR NECESSARY TO COMPLETE, REGARDLESS OF WHETHER OR NOT ALL WORK OR EACH ITEM IS SPECIFICALLY INDICATED ON ANY OTHER PORTION OF THE DRAWINGS AND / OR NOTES. 3.0 WHERE MATERIALS REFERENCED ON DRAWINGS, OR NECESSARY TO COMPLETE THE WORK OF THIS CONTRACT ARE NOT SPECIFIED HEREIN, PROVIDE BEST QUALITY MATERIALS. WHERE MATERIALS ARE INTENDED TO MATCH EXISTING, PROVIDE CLOSEST POSSIBLE MATCH, SUBJECT TO OWNER'S APPROVAL. ALL ITEMS AND WORK ON DRAWINGS ARE NEW, UNLESS INDICATED EXISTING. ALL WORK WHICH HAS BEEN DAMAGED SHALL BE REPAIRED OR REPLACED AT NO COST TO THE OWNER. WHERE ITEMS CAN NOT BE REPAIRED TO A ""NEW CONDITION"", OR WHERE THE STRUCTURAL INTEGRITY HAS BEEN AFFECTED, ITEMS SHALL BE REPLACED AT NO COST TO THE OWNER. 4.0 CONTRACTOR IS RESPONSIBLE TO VERIFY ALL SITE, FIELD AND BUILDING CONDITIONS PRIOR TO SUBMITTING BIDS AND COMMENCING WORK. IF THERE ARE ANY DISCREPANCIES BETWEEN DRAWINGS AND FIELD CONDITIONS, NOTIFY THE PROJECT MANAGER, WHO WILL REQUEST CLARIFICATION FROM THE ARCHITECT/ENGINEER AND PROVIDE CLARIFICATION IN WRITING. 5.0 WHERE EXISTING CONSTRUCTION OR ITEMS HAVE BEEN INFILLED, REMOVED AND / OR DISTURBED FOR INSTALLATION OF NEW WORK, CAUSING THE EXPOSURE OF UNFINISHED AND/OR DAMAGED SURFACES RESULTING SURFACES AND INFILLED SURFACES SHALL BE RECONSTRUCTED WITH MATERIALS TO MATCH FINISHED AREAS. ALL ABANDONED OPENINGS (i.e. DUCT/PIPE REMOVALS, ETC.) AT WALLS, ROOF OR FLOOR TO BE INFILLED SOLID. 6.0 WORK IS REQUIRED IN VARIOUS PORTIONS OF THE FACILITY TO EXECUTE WORK OF OTHER TRADES (i.e. ELECTRICAL, MECHANICAL). ALTHOUGH NOT NECESSARILY SHOWN ON DRAWINGS, WORK IS REQUIRED IN THESE AREAS CONSISTING OF REMOVAL / REPLACEMENT OF CEILINGS, WALLS, FINISHES, PAVEMENT AND OTHER CONSTRUCTION AS NECESSARY TO PERFORM WORK AND RESTORE THESE SPACES OR AREAS TO ORIGINAL CONDITION. 7.0 GENERAL CONTRACTOR IS TO COORDINATE WORK OF ALL TRADES. SCHEDULE WORK PROGRESS THROUGHOUT THE ENTIRE PROJECT TO PREVENT CONFLICTS AND INTERFERENCES. OBTAIN ALL NECESSARY INFORMATION SUCH AS SIZES, LOCATIONS, TEMPLATES, LAYOUT, DIMENSIONS AND ALL OTHER INFORMATION NECESSARY FOR A PROPER AND WELL COORDINATED INSTALLATION. PRIOR TO INSTALLATION OF ITEMS, VERIFY AND CONFIRM WITH EACH CONTRACTOR EXACT LOCATION OF ALL ITEMS. 8.0 ALL PENETRATIONS (EXISTING OR NEW) THROUGH FLOORS AND FULL HEIGHT WALLS - IN AREA OF WORK TO BE FIRE STOPPED. ALL GAPS AND JOINTS AT RATED FLOORS, ROOFS AND WALLS TO BE FIRE & SMOKE STOPPED. GAPS AND JOINTS INCLUDE (BUT ARE NOT LIMITED TO) TOP OF WALL TO FLOOR OR ROOF DECK, WALL TO BEAMS, AND CONTROL OR EXPANSION JOINTS. FIRE STOPPING INCLUDES BOTH FORM OR PACKING MATERIAL AND THE FILL, VOID OR CAVITY MATERIAL. PROVIDE AND INSTALL LABELING REQUIRED BY CODE. LABELS SHALL INCLUDE PENETRATION TYPE WITH UL LISTING USED, MATERIAL USED, DATE INSTALL AND NAME OF INSTALLER. 9.0 JOBSITE WILL BE CLEANED DAILY AND DEBRIS REMOVED TO CONTAINERS OR TO VEHICLE WHICH WILL REMOVE DEBRIS FROM CAMPUS. CONTAINERS WILL BE REMOVED AS SOON AS FULL OR WHEN THE PROJECT HAS PROGRESSED TO A POINT THAT A CONTAINER IS NO LONGER REQUIRED. 10.0 CONTRACTOR IS RESPONSIBLE FOR PROTECTING ALL AREAS USED TO BRING SUPPLIES AND EQUIPMENT INTO THE PROJECT AREA. ANY DAMAGE TO AREAS OUTSIDE THE PROJECT AREA INCLUDING BUT NOT LIMITED TO THE LOBBY AND CORRIDOR SHALL BE REPAIRED AT NO COST TO THE OWNER. 1 10/31/19 ISSUE FOR PERMIT 15 H D C B A 16 17 19 Fa E 16' - 0"16' - 0"16' - 0"16' - 0"16' - 0"16' - 0"5' - 0"27' - 0"21' - 0"16' - 0"D1 D1 D2 D3 D6 D4 D5D5 B55B00UC B60A B63 B62A B62 B64 B66 B00UE B60B B60B56 B56A B54 B00CA D6 D7 D7 3 5/8" METAL STUD TRACK SECURED TO FLOOR WITH POWER DRIVEN FASTENERS @ 12" O.C. MAX. 5/8" GYPSUM WALLBOARD BOTH SIDES -TAPED, SPACKLED & PAINTED (2 COATS) 3 5/8" METAL STUDS (20GA) @ 16" O.C. PLAN FLOOR LINE -0' -0" SECTION SECTION UNDERSIDE OF EXISTING GWB SOFFIT - 8' - 5" A.F.F. WALL TYPE 1 3/4" TH X 4-1/2" H SMOOTH WHITE PVC TRIM BOARD -BOTH SIDES OF WALL 3 1/2" SOUND ATTENUATION INSULATION U.L. APPROVED FIRE RATED NON- HARDENING SOUND SEALANT 3 5/8" METAL STUDS (20GA) @ 16" O.C. EXISTING SOFFIT WALL TO REMAIN. ALIGN FINISH OF NEW WALL WITH EXISTING SOFFIT WALL ABOVE EXISTING CONCRETE FLOOR SLAB ABOVE 1/2" U.L. APPROVED FIRE RATED NON-HARDENING SOUND SEALANT SECURED TRACK TO GWB WALL WITH POWER DRIVEN FASTENERS @ 12" O.C. MAX. PRIOR TO CONSTRUCTION, CONTRACTOR TO REVIEW EXISTING SOFFIT & BRACING W/ FE ENGINEERING. ASSUME 3-5/8" STUDS @ 48" O.C.. EXIST'G FINISH WALL TO BE REMOVED AS REQ'D TO INSTALL NEW BRACING. PATCH, REPAIR & PAINT. 1/4" CLEAR LAM SAFETY "FIRELITE" GLASS 42"30"2"AS SCHEDULED 2"AS SCHEDULED2"6"6" DR1 NEW H.M. DOOR FRAME - PRIMED & PAINTED. PREP FRAME TO FOR CARD ACCESS. REFER TO DOOR / HARDWARE SCHEDULE FOR RATED FRAMES EXIST'G METAL CASEWORK TO REMAIN EXIST'G METAL COUNTERTOP TO SCRAPED, PRIMED & PAINTED EXIST'G C.M.U. WALL TO BE REMOVED. PATCH, REPAIR, PAINT WALLS TO REMAIN WHERE REMOVED. PATCH REPAIR & PAINT FLOOR & CEILING WHERE REMOVED. EXIST'G WALLS TO BE PATCHED, PRIMED & PAINTED EYEWASH ADA 6" DP SINK & ADA FAUCET CONTROLS -REFER TO MECHANICAL DRAWINGS NEW 2" EPOXY RESIN COUNTERTOP STEEL SINK CABINET (MODEL #15K3011) AS MANUFACTURED BY MOTT OR APPROVED EQUAL (COLOR "BATTLESHIP GREY") WITH 2" TH. EPOXY RESIN COUNTERTOP. UNIT TO BE 48"W X 25" DEEP WITH COUNTERTOP SET AT 34" A.F.F.. MODIFY EXISTING C.M.U. & METAL BASE CABINETS AS REQUIRED TO INSTALL NEW PLUMBING & CASEWORK. EXISTING C.M.U. TO BE PATCHED, REPAIRED & PAINTED AS REQUIRED PER INSTALLATION OF NEW PLUMBING PIPING ADA FRONT ACCESSIBLE 4' - 0"2' - 10"CORNE LL U N I V E RSI TYFOUN D E D 5681 AD FACILITIES ENGINEERING N ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 HOLLISTER HALL Hollister Hall B55, B60, B60A, B60B, B63, B64 Lab Renovations A-102 12025236 PARTIAL - BASEMENT DEMOLITION PLAN R.HERKO RLH 2046 OCTOBER 31, 2019 SCALE: 1/8" = 1'-0" 1 BASEMENT - DEMOLITION FLOOR A-102 DEMOLITION KEY NOTES D1 REMOVE EXISTING CONCRETE MASONRY WALL D2 REMOVE EXISTING DOOR. FRAME TO REMAIN. PREP OPENING FOR WALL IN-FILL D3 EXISTING TALL WOOD CASEWORK TO BE RELOCATED. REFER TO RENOVATION PLAN FOR NEW LOCATION. D4 EXISTING TALL METAL CABINETS TO BE RELOCATED. REFER TO RENOVATION PLAN FOR NEW LOCATION. D5 REMOVE 2 ROWS OF EXISTING V.A.T. FLOORING EACH SIDE OF EXISTING WALL UNDER ASBESTOS ABATEMENT PROCEDURES. D6 REMOVE EXISTING DOOR AND FRAME. PREP OPENING TO RECEIVE NEW DOOR AND HARDWARE. D7 REMOVE EXISTING WOOD TRIM AT BOTTOM OF EXISTING GWB SOFFIT ABOVE. PREP EXISTING TO RECEIVE NEW GWB ALIGNED TO EXISTING. SCALE:1 1/2" = 1'-0"2 WALL TYPE W1 SCALE: 3/8" = 1'-0" 3 DOOR & DOOR FRAME TYPES DEMOLITION NOTES: DEMOLITION SCHEDULE SHOULD BE COORDINATED WITH CORNELL UNIVERSITY AND CLASS SCHEDULES TO AVOID DISRUPTION OF STUDENTS AND TEACHERS. NO HEAVY CONSTRUCTION SUCH AS BUT NOT LIMITED TO: CORE DRILLING, HAMMERING, BLOCK REMOVAL, SANDING, GRINDING, SAW CUTTING, ETC. BETWEEN 9:00AM AND 5:00 PM ON DAYS WHEN CLASSES ARE IN SESSION ABOVE OR BELOW WORK. PATCH AND REPAIR WITH LIKE MATERIAL TO A SMOOTH FINISH AT ALL REMOVED LIGHTS, ELECTRICAL BOXES, PIPING, HANGERS, MECHANICAL EQUIPMENT, EXISTING HOLES, ETC.. SEE MECHANICAL, ELECTRICAL, AND PLUMBING DEMOLITION DRAWINGS. FIELD VERIFY ALL EXISTING CONDITIONS @ FLOORS, WALLS, AND CEILINGS. PATCH AND REPAIR WALLS WHERE INTERSECTING WALLS HAVE BEEN DEMOLISHED TO A SMOOTH FINISH. SEE ASBESTOS SPECIFICATION AND DOCUMENTS FOR REMOVAL OF HAZARDOUS MATERIAL. PATCH AND REPAIR FLOOR TO A SMOOTH FINISH TO EXCEPT NEW FLOOR FINISH. ALL FLOORS ARE TO BE CLEAN AND FREE FROM DEBRIS AND IMPERFECTIONS TO MEET FLOOR FINISH MANUFACTURER'S REQUIREMENTS FOR NEW FLOORING AND FLOORING FINISH INSTALLATION. REMOVE ALL UNUSED OR ABANDONED CONDUIT, PIPING, HANGERS, CABLES, ELECTRICAL BOXES, MECHANICAL EQUIPMENT, ETC. ON THE CEILINGS AND WALLS AND COLUMNS, COORDINATE WITH CORNELL UNIVERSITY AND MECHANICAL, ELECTRICAL, AND PLUMBING DEMOLITION DRAWINGS. COORDINATE WITH ELECTRICAL, STRUCTURAL, AND PLUMBING DRAWINGS FOR ADDITIONAL SAW CUTTING OF EXISTING CONCRETE SLAB, FOR CONDUIT, MECHANICAL DUCTWORK, PIPING LINES ETC.. AFTER COMPLETION OF DEMOLISHED ITEMS THAT PENETRATE THROUGH THE FLOOR PROVIDE A METAL PLATE BOLTED TO BOTTOM OF EXISTING FLOOR SLAB AND INFILL HOLE WITH CONCRETE TO ALIGN WITH EXISTING FLOOR SLAB. ROOM SCHEDULE SPACE FLOOR BASE WALLS CEILING DOORS FRAMES FINISH NOTESNO. NAME N E S W FIN. HGT. BASEMENT FLOOR - REFLECTED CEILING PLAN B00CA CORRIDOR EXT'G EXT'G EXT'G EXT'G EXT'G EXT'G EXT'G EXT'G EXT'G EXT'G B00UC UTILITY AREA EXT'G EXT'G EXT'G EXT'G EXT'G EXT'G EXT'G EXT'G EXT'G EXT'G B55 DATA PROCESSING COMPUTER CONC / PAINT VCB PAINT PAINT PAINT PAINT PAINT EXT'G. STAIN PAINT B56 MACHINE SHOP EXT'G EXT'G EXT'G EXT'G EXT'G EXT'G EXT'G EXT'G EXT'G EXT'G B56A OFFICE EXT'G EXT'G EXT'G EXT'G EXT'G EXT'G EXT'G EXT'G EXT'G EXT'G B60 CLASS LABORATORY WET CONC VCB PAINT PAINT PAINT PAINT EXT'G EXT'G STAIN PAINT B60B PUMP AREA EXT'G EXT'G EXT'G EXT'G EXT'G EXT'G EXT'G EXT'G EXT'G EXT'G B62 CLOSET EXT'G EXT'G EXT'G EXT'G EXT'G EXT'G EXT'G EXT'G EXT'G EXT'G B62A CLOSET EXT'G EXT'G EXT'G EXT'G EXT'G EXT'G EXT'G EXT'G EXT'G EXT'G B64 NON-CLASS LABORATORY SERVICE CONC / PAINT VCB PAINT PAINT PAINT PAINT EXT'G EXT'G STAIN PAINT B66 MECHANICAL EXT'G EXT'G EXT'G EXT'G EXT'G EXT'G EXT'G EXT'G EXT'G EXT'G SCALE: NO SCALE 5 PHOTO - ROOM B55 SCALE: 1/4" = 1'-0" 4 ADA SINK CASEWORK DOOR / HARDWARE SCHEDULE DOOR DOOR FRAME FIRE RATINGHARDWARE DETAILS NOTESDOOR LOCATION HAND PANEL SIZE ELEVATION TYPEMATERIALFINISHMATERIALFINISHSILENCERS DCI 8SHINGES MCKINNEY TA2714 X 4.5 X 4.5 X NRP X US10HINGES MCKINNEY TA2714 X 4.5 X 4.5 X NRP X US10SELF LATCHING FLUSH BOLTS DCI 945 X US10SARGENT 60-8205 LNL 26D (04 FUNCTION) LOCKSETMCKINNEY CABLES QC-C300 38"MCKINNEY CABLES QC-C1500P 15'-2”SARGENT 8205 X LNL X US10 X RH70-M182271 X 24 VOLTS X BIPS X B X 03 X LNL X US10 X LH70-M182271 X 24 VOLTS X BIPS X B X 03 X LNL X US10 X RHRBADOOR COORDINATORS DCI # 672 X PAINTMOUNTING BRACKETS FOR SOFFIT APPLIED HARDWARE DCI 600DRESTRICTED CYLINDER PROVIDED BY THE ZONE LOCKSMITHCLOSER SARGENT 351 X O X EP X 120 DEGREECLOSER SARGENT 351 X P9 X EP X 120 DEGREE SARGENT CONCEALED OVERHEAD STOP 698S X US10 X 110 DEGREEWALL BUMPERS DCI 3211T X US10HEAD JAMB# OF PANELSWIDTHHEIGHTTHICKNESSDR-1 B55 TO B00CA LH (1) 3' - 0" 7' - 0" 1 3/4" DR1 WD STAIN HM PNT Y 3 3 1 1 1 1 1 1 DR-2 B60 TO B00CA RHRBA (1) 6' - 0" 7' - 0" 1 3/4" DR1 WD STAIN HM PNT Y 2 6 1 1 1 1 1 1 2 1 2 2 DR-3 B64 TO B60 RH (1) 3' - 0" 7' - 0" 1 3/4" DR1 WD STAIN HM PNT N 3 3 1 1 1 DOOR HARDWARE NOTES: 1)CONTACT KEVIN BARNHART AT 607-327-1606 FOR HIS INFORMATION ON THIS PROJECT. 2)CONTACT TIM PATRIWSKY AT 607-255-9798 FOR HIS INFORMATION ON THIS PROJECT. 3) CARD ACCESS:FREE EGRESS FROM INSIDE AT ALL TIMES. CYLINDER IN DEVICE IS IF THE CARD ACCESS FAILS. WHEN YOU PRESENT A VALID PROXIMITY CARD TO THE READER THE OUTSIDE LEVER WILL UNLOCK AND THE LEVER CAN BE DROPPED AND THE DOOR PULLED OR PUSHED OPEN. OUTSIDE LEVER CAN BE LOCKED AND UNLOCKED BY THE CARD ACCESS SYSTEM. DOOR POSITION IS MONITORED THRU THE LATCH BOLT. REQUEST TO EXIT IS IN THE INSIDE LEVER. 1 10/31/19 ISSUE FOR PERMIT CR CR 15 D C B A 16 17 19 Fa E CLASS LABORATORY WET B60 CLOSET B62A CLOSET B62 NON-CLASS LABORATORY SERVICE B64 MECHANICAL B66 16' - 0"16' - 0"16' - 0"16' - 0"16' - 0"27' - 0"21' - 0"16' - 0"A2 A2 A2 A3 A3 A1 A3 +/- 8' - 8"A4 A5 A6A6A6 A6A6 A6A6A6A6 A6A6 A6 A3 A7 A7 A7 A7 A7 A7 A7 A7 A7A7 A7 A8 A8 A8 A8 A8 A8 A8 A8 A9 A9 A10 A10 A10 A10 A10 A10 DATA PROCESSING COMPUTER B55 CLASS LABORATORY WET B60 UTILITY AREA B00UC MACHINE SHOP B56 OFFICE B56A PUMP AREA B60B CORRIDOR B00CA A11 A11 A12A12 A13 A14 A14A14 A14 A15A15A15 A15 A15 A15 A16A16 A15 A15 A15 A17 A18 A18 A19 A19 A15 A15 DR-3 A20 A21 A21 A23 W1 0 +/- 11' - 3"+/- 10' - 9"A22 2 A-102 4' - 0"A1 A24 A252' - 1" A-1024 A26 DR-1 DR-2 A27 A23 A28A29 A15 A11 A15 A15 3' - 6" A30 A31 A32 A33 A34 EXIST'G CONC EXIST'G V.A.T. EXIST'G CONC EXIST'G V.A.T. A34 A34 A34 CORNE LL U N I V E RSI TYFOUN D E D 5681 AD FACILITIES ENGINEERING N ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 HOLLISTER HALL Hollister Hall B55, B60, B60A, B60B, B63, B64 Lab Renovations A-103 12025236 RENOVATION - BASEMENT FLOOR PLAN RLH R. HERKO 2046 OCTOBER 31, 2019 SCALE: 1/4" = 1'-0" 1 RENOVATION BASEMENT FLOOR PLAN A-103 RENOVATION KEY NOTES A1 PROVIDE & INSTALL - ADA COMPLIANT - STEEL SINK CABINET (MODEL #15K3011) AS MANUFACTURED BY MOTT OR APPROVED EQUAL (COLOR "BATTLESHIP GREY") WITH 2" TH. EPOXY RESIN COUNTERTOP. UNIT TO BE 48"W X 25" DEEP WITH COUNTERTOP SET AT 34" A.F.F.. MODIFY EXISTING C.M.U. & METAL BASE CABINETS AS REQUIRED TO INSTALL NEW PLUMBING & CASEWORK. PATCH & REPAIR EXISTING CASEWORK AS REQUIRED TO INSTALL NEW. A2 PROVIDE & INSTALL ADA COMPLIANT WORK STATION - DESK HEIGHT TO BE SET AT 34" A.F.F. A3 EXISTING STEEL CASEWORK AND COUNTERTOP TO REMAIN. CONTRACTOR TO LIGHTLY GRIND STEEL COUNTERTOP SMOOTH OF ALL RUST, PREP, PRIME AND PAINT COUNTERTOP. A4 ALIGN END OF WALL WITH EXISTING SOFFIT WALL ABOVE A5 INFILL DOOR OPENING WITH 3-1/2" 20 GA. METAL STUDS @ 16" O.C. & 5/8" GYP. WALL BOARD. TAPED, SPACKLED & 2 COATS OF PAINT. WALL FINISH ON BOTH SIDES OF WALL TO ALIGN WITH ADJACENT EXISTING WALLS. VERIFY STUD WIDTH. A6 RELOCATED 30" DP X 60" W WORK STATION. A7 NEW 30" DP X 60" WORK STATION SUPPLIED & INSTALLED BY OWNER. A8 RELOCATED 3D PRINTER ENCLOSURE & STAND PROVIDED BY OWNER A9 RELOCATED TEST FRAME & STAND PROVIDED BY OWNER A10 RELOCATED WOOD CABINET A11 ADA DOOR CLEARANCE AREA. SPACE TO REMAIN FREE OF ANY EQUIPMENT OR FURNITURE A12 PROVIDE METAL CLOSURE PANEL AT SIDE OF EXISTING CASEWORK AFTER REMOVAL OF C.M.U. WALL. PAINT METAL CLOSURE TO MATCH A13 NEW WALL - 3-5/8" METAL STUDS (20 GA) @ 16" O.C. WITH 5/8" GYP. WALL BOARD EACH SIDE. PRIME AND TWO COATS OF PAINT MANUF. "SHERWIN WILLIAMS, COLOR "SNOWBOUND SW/7004" "DURATION HOME INTERIOR LATEX EGGSHELL. - ALIGN NEW WALL WITH WALL ABOVE (SEE DETAIL 2/A-102) A14 PATCH AND REPAIR EXISTING WHERE C.M.U. WAS REMOVED. MANUF. BY "SHERWIN WILLIAMS" COLOR:"SNOWBOUND SW 7004". INCLUDE PAINTING ANY EXPOSED SURFACE MOUNTED CONDUIT, A15 EXISTING WALL TO BE PATCHED, PRIMED & PAINTED (2 COATS). MANUF. BY "SHERWIN WILLIAMS" COLOR:"SNOWBOUND SW 7004". INCLUDE PAINTING ANY EXPOSED SURFACE MOUNTED CONDUIT, A16 PROVIDE AND INSTALL NEW 48"H X 120"W WHITEBOARD. SET TOP OF BOARD AT 7'-4" A.F.F. A17 NEW 3'-0" X 7'-0" H.M. DOOR SET INTO EXISTING H.M. DOOR FRAME. MODIFY EXISTING FRAME AS REQUIRED TO RECEIVE NEW DOOR AND HARDWARE. REPAIR DOOR WHERE HINGES AND STRIKE WERE REMOVED. PATCH & PAINT FRAME. PROVIDE NEW ADA COMPLIANT HARDWARE (OFFICE FUNCTION). MANUF. BY "ALGOMA HARDWOODS" "PLAIN SLICED WHITE OAK RA 100 CLEAR FINISH". 2" H.M. FRAME PAINTED "SHERWIN WILLIAMS" "PASSIVE SW7064" "DURATION HOME INTERIOR LATEX EGGSHELL". A18 PATCH, REPAIR UNDERSIDE OF EXISTING BEAM ABOVE WHERE WALL WAS REMOVED. MATCH CEILING PAINT COLOR. A19 PATCH FLOOR AS REQUIRED WHERE WALL WAS REMOVED. MATCH CEILING PAINT COLOR. A20 EXISTING OVERHEAD DOOR TO REMAIN. A21 EXISTING RELOCATED TALL METAL CABINETS A22 EXISTING STEEL CAGE AREA TO REMAIN. SEE NOTE A23 A23 DASHED LINE INDICATES EXTENT OF NEW 2" TH X 48" W X 84" H QUILTED CURTAIN S.T.O.P. (NOISE ABSORBING CURTAIN WITH FIBERGLASS CORE, FACED WITH QUILTED VINYL COATED FABRIC.) SECURED TO THE EXISTING CAGE FRAMING WITH HEAVY DUTY ZIP TIES AT 12” O.C. AT TOP AND BOTTOM. MODEL #BSC-25 w/ 1lb. BARRIER (2 SIDED QUILTED CURTAIN WITH 9/16” STAINLESS STEEL GROMMENTS - ASTM E84, CLASS A), COLOR BLACK, MANUFACTURED BY ACOUSTICAL SURFACES, INC. WEBSITE: ACOUSTICALSURFACES.COM, TEL:1-855-303-9959. A24 PROVIDE & INSTALL - ADA COMPLIANT SINK AND CONTROLS INTO NEW ADA COMPLIANT METAL CASEWORK & 2" TH. EPOXY RESIN COUNTERTOP A25 PROVIDE & INSTALL - EYE WASH UNIT IN NEW ADA COMPLIANT SINK A26 EXISTING EMERGENCY SHOWER AND EYE WASH UNIT A27 PROVIDE 28" X 60" STEEL TABLE (MODEL #ATF2260) AS MFGR BY MOTT MANUFACTURING OR APPROVED EQUAL AND PROIVDE 2" EPOXY RESIN TABLE TOP. A28 PROVIDE & INSTALL "MAPES-R PANEL" OR APPROVED EQUAL NSULATED KYNAR FINISH METAL PANEL WITH CEMENT BOARD SUBSTRATE AND POLYISO INSULATION BOARD INTO EXISTING WINDOW FRAME OPENING WHERE EXISTING AIR HANDLING UNIT WAS REMOVED. A29 PROVIDE & INSTALL "MAPES-R PANEL" OR APPROVED EQUAL NSULATED KYNAR FINISH METAL PANEL WITH CEMENT BOARD SUBSTRATE AND POLYISO INSULATION BOARD INTO EXISTING WINDOW FRAME OPENING WHERE EXISTING AIR HANDLING UNIT WAS REMOVED. CUT NEW PANEL AND SEAL AROUND NEW AIR HANDLING UNIT IN FRAME. A30 AREA OF RECESSED WALL AREA IN EXISTING SOFFIT WALL ABOVE TO REMAIN OPEN. A31 RELOCATED TABLETOP FURNACE UNIT. A32 EXISTING COUNTERTOP EYEWASH UNIT TO REMAIN. A33 NEW COUNTERTOP MOUNTED EMERGENCY EYEWASH UNIT. REFER TO MECHANICAL DRAWINGS. A34 ADD ROW OF V.C.T. FLOORING AGAINST EXISTING V.A.T. FLOORING AND PROVIDE TRANSITION STRIP FROM NEW V.CT. TO EXISTING CONCRETE FLOORING A34 PROVIDE 2" X 0.25" SQUARE ALUMINUM TUBING FASTENED TO DECK ABOVE AND FINISHED FLOOR AS REQUIRED. TUBING TO BE UTILIZED TO SUPPORT COMPRESSED AIR PIPING. REFER TO ROOM FINISH SCHEDULE ON DRAWING A-102 1 10/31/19 ISSUE FOR PERMIT 15 D C B A 16 17 19 Fa E A1 A2A2 A3 A4 A4 A4 11' - 0"L4 X 4 X 1/4 X 11'-0" MIN. 4 UNISTRUT SUPPORTS BETWEEN COL. D & C CORNE LL U N I V E RSI TYFOUN D E D 5681 AD FACILITIES ENGINEERING N ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 HOLLISTER HALL Hollister Hall B55, B60, B60A, B60B, B63, B64 Lab Renovations A-401 12025236 PARTIAL BASEMENT REFLECTED / STRUCTURAL FRAMING CEILING PLAN R. HERKO RLH 2046 OCTOBER 31, 2019 SCALE:1/8" = 1'-0"1 PARTIAL BASEMENT FLOOR - REFLECTED CEILING / STRUCTURAL FRAMING PLAN A-401 RENOVATION KEY NOTES A1 NEW AIR HANDLING UNIT (AHU-1) SUPPORTED FROM EXISTING CONCRETE DECK ABOVE. SEE NOTE A3 / A401 FOR SUPPORT FRAME CONSTRUCTION. BASIS OF DESIGN WEIGHT 1,500 LB. A2 PATCH, REPAIR UNDERSIDE OF EXISTING BEAM ABOVE WHERE WALL WAS REMOVED. MATCH CEILING PAINT COLOR. A3 AT EACH CONCRETE BEAM ON GRIDS C AND D, PROVIDE (1) 11'-0" LONG L4X4X1/4 ANGLE CENTERED ON THE LOCATION OF THE MECHANICAL UNIT AND WITH THE HORIZONTAL LEG ABOVE THE VERTICAL LEG. ATTACH ANGLES TO CONCRETE BEAMS WITH 1/4" DIAMETER STAINLESS STEEL POWERS POWER-STUD ANCHORS TO BE EMBEDDED A MINIMUM OF 2" AND TO BE SPACED A MAXIMUM OF 2'-0" ON CENTER. END ANCHORS SHALL BE LOCATED 2" FROM EACH END OF THE ANGLE. ANCHORS TO BE CENTERED ON THE HEIGHT OF THE VERTICAL LEG. PROVIDE OVERSIZED HOLES IN THE ANGLE LEG FOR THE ANCHORS TO ALLOW FOR ADJUSTABILITY AFTER ANCHORS ARE INSTALLED. ANCHORS MUST BE PLACED A MINIMUM OF 3" FROM THE EDGE OF THE CONCRETE AND A MINIMUM OF 4" FROM OTHER EMBEDDED ITEMS. PROVIDE A MINIMUM OF (4) PIECES OF UNISTRUT SPANNING BETWEEN THE CONCRETE BEAMS ON GRIDS D AND C TO SUPPORT THE MECHANICAL UNIT. IF THE UNIT HAS MORE ATTACHMENT POINTS, PROVIDE UNISTRUT AT EACH ATTACHMENT POINT. UNISTRUT TO BEAR ON ANGLES. ATTACH UNISTRUT TO ANGLES WITH SCREWS CENTERED ON THE WIDTH OF THE HORIZONTAL LEG. FACILITIES ENGINEERING MUST REVIEW ANCHOR LAYOUT IN THE FIELD BEFORE INSTALLATION SO THAT ANCHORS DO NOT CONFLICT WITH THE EXISTING REINFORCEMENT. ANCHORS WILL BE IN TENSION AND THEREFORE WILL REQUIRE SPECIAL INSPECTIONS. A4 SEAL UP PIPE PENTRATIONS, WALL OPENINGS, DUCT PENTRATIONS THROUGH EXISTING WALL. REPAIR ANY DAMAGED C.M.U'S IN WALL. PATCH & PAINT. 1 10/31/19 ISSUE FOR PERMIT CORNE LL U N I V E RSI TYFOUN D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 FACILITY NAME Hollister Hall B55, B60, B60A, B60B, B63, B64 Lab Renovations M-001 12025236 GENERAL NOTES AND SYMBOL LEGENDS A. FOX ALF 2046 OCTOBER 31, 2019 MECHANICAL & PLUMBING ABBREVIATIONS BCU BLOWER COIL UNIT CHWR CHILLED WATER RETURN CHWS CHILLED WATER SUPPLY CC CLEAN CONDENSATE CO CLEAN OUT CS CLEAN STEAM CA COMPRESSED AIR CD CONDENSATE DRAIN DHW DCOMESTIC HOT WATER DCW DOMESTIC COLD WATER EEW EMERGENCY EYE WASH EA EXHAUST AIR EAG EXHAUST AIR GRILLE FD FIRE DAMPER FD FLOOR DRAIN GWR GLYCOL HEATING RETURN GWS GLYCOL HEATING SUPPLY HPR HIGH PRESSURE STEAM RETURN HPS HIGH PRESSURE STEAM SUPPLY HWR HOT WATER HEATING RETURN HWS HOT WATER HEATING SUPPLY LPC LOW PRESSURE CONDENSATE LPS LOW PRESSURE STEAM MU MAKE UP WATER MPC MEDIUM PRESSURE CONDENSATE MPS MEDIUM PRESSURE STEAM NG NATURAL GAS PCWR PROCESS CHILLED WATER RETURN PCWS PROCESS CHILLED WATER SUPPLY HG REFRIGERANT HOT GAS RL REFRIGERANT LIQUID RS REFRIGERANT SUCTION RAG RETURN AIR GRILLE SV SANITARY VENT SW SANITARY WASTE SA SUPPLY AIR SAD SUPPLY AIR DIFFUSER TW TEMPERED WATER TV TEMPERING VALVE VAC VACUUM VD VOLUME DAMPER MECHANICAL SYMBOLOGY AIRFLOW BACKFLOW PREVENTER BALANCE VALVE BALL VALVE BOTTOM PIPE CONNECTION BUTTERFLY VALVE CAP OR PLUG CHECK VALVE CIRCULATING PUMP DIRECTION OF FLOW DUCT AIRFLOW DUCT DOWN (EXHAUST OR RETURN) DUCT DOWN (SUPPLY) FIRE AND SMOKE DAMPER IN DUCT FIRE DAMPER IN DUCT FLANGE CONNECTION FLEX CONNECTOR FLEXIBLE CONNECTION FLEXIBLE DUCT FLOW METER FLOW SWITCH FUSIBLE LINK VALVE GLOBE VALVE MANUAL AIRVENT ORIFICE METER PIPE DOWN PIPE UP PIPING REDUCER (CONCENTRIC) PIPING REDUCER (ECCENTRIC) PRESSURE GAUGE PRESSURE OR TEMPERATURE PETES PLUG PRESSURE REDUCING VALVE PRESSURE SWITCH RECTANGULAR ELBOW RECTANGULAR ELBOW WITH TURNING VANES RELIEF VALVE SMOKE DAMPER IN DUCT SOLENOID VALVE STANDARD BRANCH DUCT STEAM TRAP STRAINER (DUPLEX) STRAINER WITH BLOWDOWN VALVE AND CAP SUPPLY THROUGH NEXT FLOOR OR ROOF TEMPERATURE WELL THERMOMETER THERMOMETER (DIAL) TOP PIPE CONNECTION TRIPLE DUTY VALVE UNION CONNECTION VACUUM BREAKER VOLUME DAMPER IN DUCT CONTROL SYMBOLOGY 2-WAY CONTROL VALVE, DIGITAL 2-WAY CONTROL VALVE, PNEUMATIC 3-WAY CONTROL VALVE, DIGITAL 3-WAY CONTROL VALVE, PNEUMATIC ADDRESSABLE OUTPUT MODULE (FIRE ALARM INTERFACE) AIRFLOW CONTROL VALVE (VENTURI OR VORTEX SHEDDING) AVERAGING SENSOR BINARY POINT BUTTERFLY CONTROL DAMPER CARBON DIOXIDE SENSOR CONDENSATE SENSOR CURRENT SENSOR DEW-POINT SENSOR DIFFERENTIAL PRESSURE SENSOR DIFFERENTIAL PRESSURE SENSOR ELECTRIC TO PNEUMATIC SWITCH ELECTRIC TO PNEUMATIC TRANSDUCER END SWITCH FLOW ELEMENT (METER) FLOW SENSOR HIGH LEVEL SWITCH HUMIDSTAT SENSOR LIQUID IMERSION TEMPERATURE SENSOR LOW LEVEL SWITCH MODULATING MOTOR MOTOR STARTER NETWORK COMMUNICATION POINT, BACnet MSTP OCCUPANCY SENSOR OPEN/CLOSE OPPOSED BLADE CONTROL DAMPER PARALLEL BLADE CONTROL DAMPER PNEUMATIC THERMOSTAT PRESSURE SENSOR PRESSURE SWITCH RELATIVE HUMIDITY SENSOR RELAY ROOM TEMPERATURE SENSOR WITH ADJUSTABLE THERMOSTAT ROOM TEMPERATURE SENSOR WITH OCCUPANCY OVERRIDE ROOM TEMPERATURE SENSOR WITH ON/OFF SWITCH ROOM TEMPERATURE SENSOR WITH VISUAL DISPLAY ROTATION DETECTOR SINGLE POINT SENSOR SMOKE DETECTOR SPEED COMMAND START/STOP STATIC PRESSURE SENSOR SWITCH TEMPERATURE SENSOR TEMPERATURE SENSOR TEMPERATURE SENSOR WITH ADJUSTABLE SETPOINT GENERAL DRAWING SYMBOLOGY DEMOLISHED WORK EXISTING PIPING TO REMAIN EXISTING TO REMAIN EXISTING WORK TO REMAIN NEW WORK POINT OF CONNECTION POINT OF DISCONNECTION CONTROL ABBREVIATIONS AI ANALOG INPUT AO ANALOG OUTPUT AV ANALOG VALUE BI BINARY INPUT BO BINARY OUTPUT BV BINARY VALUE F.L. FAIL LAST N.C. NORMALLY CLOSED N.O. NORMALLY OPEN VFD VARIABLE FREQUENCY DRIVE MECHANICAL GENERAL NOTES 1.0 THE DRAWINGS ARE DIAGRAMMATIC AND INDICATE ONLY THE GENERAL ARRANGEMENT OF THE SYSTEMS AND WORK INCLUDED IN THE CONTRACT. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS. IF DIMENSIONS OR CONDITIONS ARE FOUND TO BE IN CONFLICT WITH THE DRAWINGS, THE CONTRACTOR SHALL IMMEDIATELY REFER THE CONFLICT TO THE PROJECT MANAGER BEFORE WORK PROCEEDS. 2.0 UTILITY SHUTDOWNS: SHUTDOWN OF ANY BUILDING UTILITY SYSTEM SHALL BE COORDINATED WITH CUSTOMER SERVICE AT PH: 607-255-5322. THE CONTRACTOR SHALL BEAR THE COST OF THE UTILITY SHUTDOWN. SCHEDULE WORK TEN DAYS IN ADVANCE AND NOTIFY THE OWNER'S REPRESENTATIVE TO COORDINATE BUILDING FUNCHTIONS WITH THE BUILDING COORDINATOR. 3.0 WORK IS REQUIRED IN VARIOUS PORTIONS OF THE FACILITY TO EXECUTE WORK OF OTHER TRADES (EG. ELECTRICAL, MECHANICAL, STRUCTURAL AND ARCHITECTURAL). ALTHOUGH NOT NECESSARILY SHOWN ON THE DRAWINGS, WORK IS REQUIRED IN THESE AREAS CONSISTING OF REMOVAL/REPLACEMENT OF CEILINGS, WALLS, FINISHES, AND OTHER CONSTRUCTION AS NECESSARY TO PERFORM WORK AND RESTORE THESE SPACES OR AREAS TO ORIGINAL CONDITION. 4.0 INSTALL EQUIPMENT TO ENSURE PROPER ACCESS TO CONTROL DEVICES AND WITH SUFFICIENT SPACE TO PERFORM ROUTINE MAINTENANCE AND REPAIR. EQUIPMENT THAT IS NOT INSTALLED WITH THIS REQUIREMENT IN MIND SHALL BE RELOCATED AT NO EXPENSE TO THE UNIVERSITY UNTIL DEFICIENCIES ARE CORRECTED. 5.0 VERIFY FINAL EQUIPMENT/FIXTURE LOCATIONS FOR ROUGHING-IN. 6.0 ALL SYSTEMS SHALL BE LABELED. SUBMITTAL TO ENGINEER FOR APPROVAL. 7.0 ALL SYSTEM TESTING SHALL BE TESTED PRIOR TO INSULATION, FIREPROOFING, AND ENCLOSURE IN SHAFTS. ANY RESTORATION WORK REQUIRED AS A RESULT OF DISTURBING FINISHES OR STRUCTURE IN ORDER TO ACCESS SYSTEMS REQUIRING REPAIR SHALL BE AT NO COST TO THE UNIVERSITY. 8.0 ASSURE PUBLIC AND WORKER SAFETY AT ALL TIMES. PROTECT ADJOINING AREAS FROM DAMAGE AND DUST. REMOVE ALL DEBRIS FROM SITE AND DISPOSE OF WASTE MATERIAL IN A SAFE MANNER. KEEP THE PREMISES FREE OF DEBRIS FROM THE EXECUTION OF WORK. DELIVER A FINAL PRODUCT THAT IS CLEAN AND OPERABLE. 9.0 FIRE STOP ALL PENETRATIONS THROUGH FIRE RATED WALLS AND/OR FLOORS WITH MATERIAL EQUAL IN RATING TO THE CONSTRUCTION OF THE MATERIAL PENETRATED. 10.0 WORK SHALL BE COMPLETED AS SPECIFIED AND INDICATED ON CONTRACT DOCUMENTS. ANY SUGGESTED ALTERNATE MANUFACTURER OR METHOD OF INSTALLATION SHALL BE SUBMITTED TO PROJECT ENGINEER FOR APPROVAL PRIOR TO ORDERING ANY MATERIALS OR COMMENCING EXECUTION OF WORK. 11.0 EXISTING EQUIPMENT SHOWN TO REMAIN SHALL BE PROTECTED DURING CONSTRUCTION. 1 9/13/19 ISSUE FOR 30% REVIEW 2 10/24/19 ISSUE FOR COORDINATED REVIEW 3 10/29/19 ISSUE FOR PERMIT 15 D C B A 16 17 19 E EXISTING OPENING FROM SUPPLY DUCT SHALL REMAIN OPEN FOR TRANSFER AIR REMOVE EXISTING 2" TAP WATER PIPING AND ACTIVATED CARBON FILTERED WATER PIPING BACK TO PENETRATION INTO ROOM REMOVE EXISTING DUCT OFFSET REMOVE EXISTING STEAM PIPING BACK TO MAIN REMOVE EXISTING EXHAUST AIR VALVE (VAV-4E) REMOVE EXISTING SUPPLY AIR GRILLE AND PATCH DUCTWORK 5 M-401 REMOVE EXISTING 8" YELLOW EXHAUST HOSE. REFERENCE DETAIL 5/M-401 FOR DISCONNECTION POINT.CORNE LL U N I V E RSI TYFOUN D E D 5681AD FACILITIES ENGINEERING N ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 FACILITY NAME Hollister Hall B55, B60, B60A, B60B, B63, B64 Lab Renovations MD-101 12025236 BASEMENT MECHANICAL HVAC & PIPING DEMOLITION PLAN A. FOX ALP 2046 OCTOBER 31, 2019 SCALE: 3/16"=1'-0" 0 2 4 6 12 SCALE:3/16" = 1'-0"1 BASEMENT MECHANICAL HVAC & PIPING DEMOLITION PLAN 1 9/13/19 ISSUE FOR 30% REVIEW 2 10/24/19 ISSUE FOR COORDINATED REVIEW 3 10/29/19 ISSUE FOR PERMIT 15 D C B A 16 17 19 E AHU SHALL BE INSTALLED AT 8'-7" TO BOTTOM OF UNIT SA (E) EXHAUST AIR VALVE EAV-B60 3800 CFM 3800 CFM OA 11"X11" SA 11'-4" BOD USE EXISTING OPENING FROM EXISTING SUPPLY DUCT TO TRANSFER AIR FROM B55 TO B60 EXHAUST PROVIDE NEW EYEWASH AT SINK. TIE INTO EXISTING DCW/DHW, VENT AND WASTE UNDER SINK 1 SD-2 SD-2 EA (E) 14"X9" SA 10'-5-1/2" BOD 25"X12" SA 9'-5" BOD OFFSET DUCT UNDER DCW/HW AND EXPERIMENT WATER 42"X13" SA COIL PULL ACCESS SPACE SD-1 14"X8" SA 9'-9" BOD (RUN DUCT BETWEEN LIGHTS AND OVERHEAD DUCTWORK) SD-3 TD-1 20"X12" SA 10'-4" BOD 2 2 2 2 2 2 3 4 5 SD-15 8"X 4" SA 9'-9" BOD 66 REFERENCE DETAIL 1/A-401 FOR AHU-B55 STRUCTURAL FRAMING DETAIL VD-1VD-1 VD-1 VD-1 LV-1 CD-1 OSOS OS OS OS 77 7 7 7 25" X12" SA 10'-3" BOD 5 M-401 8 OFFSET DUCT DOWN TO 7'-11" BOD 11"X11" SA OFFSET DUCT DOWN BELOW BEAM TO 9'-7" BOD 9 10 AHU-B55 EXSING OPENING IN SEPERATION WALL SHALL REMAIN OPEN FOR AIR TRANSFER (REFERENCE ARCHITECTURAL DRAWINGS FOR DETAILS) M-101 KEYED CONSTRUCTION NOTES 1 REPLACE EXISTING OFFSET WITH ACCOUSTICALLY LINED DUCT OF THE SAME SIZE. 2 REBALANCE EXISTING SUPPLY DIFFUSER TO 215 CFM. 3 BALANCE SD-3 TO 100 CFM. 4 REMOVE 8" X 16" BLOCK ABOVE DOOR AND REPLACE WITH (2) TD-1 TRANSFER GRILLES. 5 BALANCE SD-1 TO 600 CFM. 6 BALANCE SD-2 TO 605 CFM. 7 PROVIDE OCCUPANCY SENSOR AND INSTALL SO THAT IT IS VISIBLE AT ANY LOCATION IN THE ROOM. 8 OFFSET DUCT DOWN AFTER CHILLED WATER PIPING. 9 INSTALL DUCT IN PLACE OF REMOVED STEAM PIPING. INSTALL SUCH THAT DUCT IS ABOVE CORRIDOR PIPING AND BELOW BEAM THAT SEPERATES B55 AND B60. 10 REFERENCE DETAIL 5/M-401 FOR NEW 8" EXHAUST TAP. # SCALE: 3/16"=1'-0" 0 2 4 6 12CORNE LL U N I V E RSI TYFOUN D E D 5681AD FACILITIES ENGINEERING N ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 FACILITY NAME Hollister Hall B55, B60, B60A, B60B, B63, B64 Lab Renovations M-101 12025236 BASEMENT MECHANICAL HVAC CONSTRUCTION PLAN A. FOX ALF 2046 OCTOBER 31, 2019 SCALE:3/16" = 1'-0"1 BASEMENT MECHANICAL HVAC CONSTRUCTION PLAN 1 9/13/19 ISSUE FOR 30% REVIEW 2 10/24/19 ISSUE FOR COORDINATED REVIEW 3 10/29/19 ISSUE FOR PERMIT 15 D C B A 16 17 19 E REPIPE EXISTING HOT AND COLD WATER TO NEW SINK 2" DHW (E) 4" DCW (E) (2) TAP WATER (E) 2" ACTIVATED CARBON FILTER WATER (E) DROP EXPERIMENTAL WATER AND CA DOWN TO EACH TABLE IN B55 CA (E) PROVIDE NEW EYEWASH (EW-1) AT SINK. TIE INTO EXISTING DCW/DHW UNDER SINK 2" CHWS (E) 3 M-401 4" CHWS/R (E) 2" WASTE WATER (E) 1" DCW/DHW (E) 4 M-401 AHU-B55 1 2" CHWR/S 10'-10" BOP 2 5" LPS (E)5" LPS (E) 2" CHWR (E) 3 4 1/2" CA 10'-6" COP 3" LPS (E) FCU-1 (E) 1-1/4" CHWS/R (E) 2" LPC (E) 2" LPC (E) 5 TIE NEW 2" WASTE WATER PIPING INTO EXISTING SANITARY AND VENT SERVING THE EXISTING SINK. 1-1/4" CHWS/R (E) 2" VAC (E) 6 5 M-401 7 7 7 1/2" CA 9'-6" BOP 1-1/4" LPC (E) 8 PROVIDE NEW EYEWASH (EW-1) AT SINK. TIE INTO EXISTING DCW/DHW UNDER SINK 9 10 CORNE LL U N I V E RSI TYFOUN D E D 5681AD FACILITIES ENGINEERING N ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 FACILITY NAME Hollister Hall B55, B60, B60A, B60B, B63, B64 Lab Renovations M-102 12025236 BASEMENT MECHANICAL PIPING PLAN A. FOX ALF 2046 OCTOBER 31, 2019 SCALE:3/16" = 1'-0"1 BASEMENT MECHANICAL PIPING CONSTRUCTION PLAN SCALE: 3/16"=1'-0" 0 2 4 6 12 M-102 KEYED CONSTRUCTION NOTES 1 CONNECT NEW 2" CHILLED WATER TO EXISTING CHILLED WATER TAPS. 2 REFERENCE DETAIL 1/M-401 FOR CHILLED WATER PIPING CONNECTION DETAIL. 3 REFERENCE DETAIL 4/M-401 FOR EXPERIMENT WATER AND PIPING ELEVATION. 4 REFERENCE DETAIL 2/M-401 FOR STEAM PIPING DETAIL. 5 TIE NEW 1/2" CA INTO EXISING CA AND RUN PIPING ALONG SIDE EXISTING 2" ACTIVATED CARBON FILTER WATER. 6 TIE NEW WASTE AND VENT FOR NEW SINK INTO EXISTING WASTE AND VENT SERVING ADJACENT SINKS. 7 REMOVE EXISTING CA HOSE REEL BACK TO CA REGULATOR AND TIE NEW 1/2" CA INTO EXISING CA REGULATOR. RUN 1/2" CA TO EACH INSTRON MACHINE. EACH CA DROP SHALL CONNECT TO EXISTING REGULATOR THAT ASSOCIATED WITH EACH INSTRON MACHINE. CA PIPING DROPS SHALL BE SUPPORTED TO THE 2"X2" ALUMINUM POST PROVIDED BY ARCHITECTURAL. REFERENCE ARCHITECTURAL DRAWINGS FOR INSTRON AND POST LOCATIONS. 8 TIE NEW 1-1/4" LPC, 3" LPS, 2" TAP WATER AND 2" ACTIVATED CARBON FILTER WATER INTO EXISTING. 9 PROVIDE UNIONS AND ISOLATION VALVES IN EXPERIMENTAL PIPING FOR EASY REMOVAL OF PIPING AT THE LOCATION SHOWN. 10 ROUTE CHILLED WATER CONDENSATE DRAIN TO MECHANICAL ROOM FLOOR DRAIN. # 1 9/13/19 ISSUE FOR 30% REVIEW 2 10/24/19 ISSUE FOR COORDINATED REVIEW 3 10/29/19 ISSUE FOR PERMIT M-102 GENERAL NOTES 1.0 PROVIDE ISOLATION VALVES NEW POINTS OF CONNECTION FOR ALL PIPING SYSTEMS ES 3,800 CFM OA N.C. BI AO OS AV SETPOINT AV SETPOINT F.L. T AI BI CO2 AO AI FTR-1 d RH AI AV TEMP SETPOINT DEWPOINT SUPPLY AIR AI RH OS AV SETPOINT AV SETPOINT T AI BI CO2 AI RH AI LAB B55 LAB B60 F.L. AO FTR-1 EA TRANSFER DUCT (E) MOD SEQUENCE OF OPERATION SYSTEM DESCRIPTION 100% OUTSIDE AIR HANDLING UNIT (AHU-B55) EXHAUST AIR VAV (EAV-B60) CHILLED WATER COOLING COIL STEAM HEATING COIL GENERAL SYSTEM SHALL BE CONTROLLED THROUGH THE BUILDING AUTOMATION AND CONTROL SYSTEM (BACS). ALL SET POINTS SHALL BE ADJUSTABLE. THE BACS SHALL BE CAPABLE OF STARTING AND STOPPING THE SYSTEM FOR SEVEN DIFFERENT DAILY SCHEDULES PER WEEK. DURING HEATING MODE, THE HEATING CONTROL VALVE SHALL CONTINUE TO CONTROL WHEN THE FAN IS OFF FOR CONTINUED FREEZE PROTECTION. DESIGN INTENT: THE AIR HANDLING UNIT IS PROVIDING VENTILATION AIR, COOLING AND SUPPLEMENTAL HEATING TO B55 AND B60. THE UNIT SHALL PROVIDE A MINIMUM OF 6 AIR CHANGES PER HOUR WHILE THE SPACE IS OCCUPIED, THEN REDUCE TO 3 AIR CHANGES WHEN THE SPACE IS UN OCCUPIED. SETPOINTS SPACE COOLING TEMPERATURE SETPOINTS: OCCUPIED:72°F +/-2°F OCCUPIED SETBACK:72°F +/-3°F UNOCCUPIED:75°F +/-4°F SPACE HEATING TEMPERATURE SETPOINTS: OCCUPIED:72°F +/-2°F OCCUPIED SET BACK:72°F +/-3°F UNOCCUPIED:70°F +/-4°F AHU DISCHARGE AIR TEMPERATURE (DAT): SEE RESET SCHEDULE FREEZESTAT LOW LIMIT TEMPERATURE: 38 33/64°F MINIMUM SUPPLY AIR FLOW RATE: 1900 CFM MAXIMUM SUPPLY AIR FLOW RATE: 3800 CFM SYSTEM OCCUPANCY SCHEDULE: 6 AM -8 PM, MON-FRI START/STOP OUTSIDE AIR DAMPER SHALL OPEN PRIOR TO THE START OF THE AIR HANDLING UNIT. END SWITCHES SHALL CONFIRM DAMPER POSITION AND COMMAND THE AHU TO START. AIR HANDLING UNIT SUPPLY FAN SHALL BE INTERLOCKED WITH THE ASSOCIATED EXHAUST VAV (EAV-B60) AND OPERATE CONTINUOUSLY. SPACE VENTILATION CONTROL AHU (AHU-B55) SHALL OPERATE AT A CONTINUOUS RATE OF 3800 CFM DURING OCCUPIED HOURS AND 1900 CFM DURING UNOCCUPIED HOURS TO PROVIDE THE MINIMUM VENTILATION AIR TO THE SPACES. SPACE OCCUPANCY ZONE OCCUPANCY SHALL BE DETERMINED BASED ON A COMBINATION OF A TIME OF DAY SCHEDULE AND SPACE OCCUPANCY SENSORS. DURING THE SCHEDULED OCCUPANCY PERIOD, THE ZONE SHALL BE INITIALLY INDEXED TO OCCUPIED MODE AND OPERATE FOR A MINIMUM OF 30 MINUTES, AT WHICH TIME THE SPACE OCCUPANCY SENSOR SHALL INDEX THE SPACE BETWEEN OCCUPIED AND OCCUPIED SETBACK MODE. DURING THE SCHEDULED UNOCCUPIED PERIOD, THE ZONE SHALL BE INITIALLY INDEXED TO UNOCCUPIED. IF THE SPACE BECOMES OCCUPIED DURING THE UNOCCUPIED PERIOD, THE OCCUPANCY SENSOR SHALL INDEX THE SPACE TO OCCUPIED FOR FOR A MINIMUM OF 30 MINUTES AT WHICH TIME THE SPACE OCCUPANCY SENSOR SHALL INDEX THE SPACE BETWEEN OCCUPIED AND OCCUPIED SETBACK MODE FOR THE DURATION OF THE UNOCCUPIED PERIOD. ZONE TEMPERATURE CONTROL OCCUPIED HEATING: THE AHU HEATING COIL CONTROL VALVE SHALL MODULATE TO MAINTAIN A DISCHARGE AIR TEMPERATURE OF 80 °F. IF THE SPACE IS OCCUPIED DURING THE SCHEDULED OCCUPIED PERIOD AND THE SPACE TEMPERATURE FALLS BELOW THE OCCUPIED HEATING TEMPERATURE SETPOINT, THE FINTUBE RADIATION CONTROL VALVE WITHIN THE SPACE SHALL MODULATE TO MAINTAIN SETPOINT. IF THE SPACE IS STILL NOT REACHING SETPOINT, AND THE BASEBOARD RADIATION CONTROL VALVES ARE FULLY OPEN, THE AHU HEATING COIL CONTROL VALVE SHALL MODULATE AS REQUIRED TO MAINTAIN SPACE TEMPERATURE SETPOINT. OCCUPIED COOLING: IF THE SPACE IS OCCUPIED DURING THE SCHEDULED OCCUPIED PERIOD AND THE ZONE TEMPERATURE RISES ABOVE THE OCCUPIED COOLING TEMPERATURE SETPOINT, THE COOLING COIL CONTROL VALVE SHALL OPERATE AS REQUIRED TO MAINTAIN THE DISCHARGE AIR TEMPERATURE AT 55 °F. OCCUPIED SETBACK: IF THE SPACE IS UNOCCUPIED DURING THE SCHEDULED OCCUPIED PERIOD, THE ABOVE OCCUPIED HEATING/COOLING SEQUENCES SHALL APPLY TO MAINTAIN THE OCCUPIED SETBACK TEMPERATURE SETPOINTS. UNOCCUPIED HEATING: THE AHU HEATING COIL CONTROL VALVE SHALL MODULATE TO MAINTAIN A DISCHARGE AIR TEMPERATURE OF 80 °F. IF THE SPACE IS UNOCCUPIED DURING THE SCHEUDLED UNOCCUPIED PERIOD AND THE ZONE TEMPERATURE FALLS BELOW THE UNOCCUPIED HEATING TEMPERATURE SETPOINT, THE BASEBOARD RADIATION CONTROL VALVE SHALL MODULATE TO MAINTAIN THE UNOCCUPIED HEATING SETPOINT. IF THE SPACE IS STILL NOT ABLE TO REACH SETPOINT AND THE BASEBOARD RADIATION CONTROL VALVE IS FULLY OPEN, THE AHU STEAM COIL CONTROL VALVE SHALL MODULATE AS REQUIRED TO MAINTAIN SETPOINT. UNOCCUPIED COOLING: IF THE SPACE IS UNOCCUPIED DURING THE SCHEDULED UNOCCUPIED PERIOD AND THE ZONE TEMPERATURE RISES ABOVE THE UNOCCUPIED COOLING TEMPERATURE SETPOINT, THE COOLING COIL CONTROL VALVE SHALL OPERATE AS REQUIRED TO MAINTAIN THE DISCHARGE AIR TEMPERATURE AT 55 °F. IF THE SPACE BECOMES OCCUPIED DURING THE SCHEDULED UNOCCUPIED PERIOD, THE SPACE SHALL BE INDEXED TO OCCUPIED MODE AND OPERATE FOR A MINIMUM OF 30 MINUTES, AT WHICH TIME THE SPACE OCCUPANCY SENSOR SHALL INDEX THE SPACE BETWEEN OCCUPIED AND OCCUPIED SETBACK MODE FOR THE DURATION OF THE UNOCCUPIED PERIOD. FILTER STATUS THE DDC CONTROL SYSTEM SHALL MONITOR THE DIFFERENTIAL PRESSURE ACROSS THE SYSTEM FILTER BANKS. FAN SPEED CONTROL SUPPLY AIR FAN SHALL MODULATE AS REQUIRED TO MAINTAIN THE REQUIRED AIR CHANGES. SUPPLY AIR TEMPERATURE CONTROL DISCHARGE AIR TEMPERATURE RESET: THE AHU DISCHARGE AIR TEMPERATURE SHALL BE ALLOWED TO RESET BASED ON THE FOLLOWING SCHEDULE: OAT = 75 °F & ABOVE OAT = 55 °F & BELOW WHEN THE AHU DISCHARGE AIR TEMPERATURE FALLS BELOW SETPOINT, THE CHILLED WATER CONTROL VALVE SHALL CLOSE, THE STEAM COIL VALVE SHALL MODULATE AS REQUIRED TO MAINTAIN THE DISCHARGE AIR TEMPERATURE SETPOINT. WHEN THE AHU DISCHARGE AIR TEMPERATURE RISES ABOVE SETPOINT, THE STEAM COIL CONTROL VALVE SHALL CLOSE, AND THE CHILLED WATER CONTROL VALVE SHALL MODULATE AS REQUIRED TO MAINTAIN THE DISCHARGE AIR TEMPERATURE SETPOINT. SAFETIES FREEZE PROTECTION: THE SUPPLY AIR FAN SHALL SHUT DOWN, THE OUTSIDE AIR DAMPER SHALL CLOSE, AND THE CONTROL VALVES SHALL OPEN UPON ACTIVATION OF THE LOW LIMIT TEMPERATURE SWITCH. AI T AV DEWPOINT AI T AI RH * 55/64 63/64 * 9/32P AI DP N.C. C C AO H C N.O. AO AI T TO FAN CIRCUIT S S MSBO BICS M sa d sa EF-1 LOCATED IN PENTHOUSE AV: FLOW FEEDBACK (CFM) AV: POSITION FEEBACK (%) AV: FLOW SETPOINT (CFM)MOD EAV-B60 AO COM BACnet / ARCNET OR BACnet / MSTP TO EF-1 LAB B56 OFFICE B64 EA TRANSFER DUCT CORNE LL U N I V E RSI TYFOUN D E D 5681AD FACILITIES ENGINEERING N ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 FACILITY NAME Hollister Hall B55, B60, B60A, B60B, B63, B64 Lab Renovations M-301 12025236 CONTROLS A. FOX ALF 2046 OCTOBER 31, 2019 ZONE CONTROL AND ALARM POINTS SCHEDULE ZONE CONTROL: AHU-B55, EAV-B60 HARDWARE POINTS SOFTWARE POINTS SHOW ON GRAPHIC NOTESBI BO AI AO AV BV SCH TREND ALARM BACS EMCS DESCRIPTION SPACE TEMPERATURE SETPOINT X X X SPACE TEMPERATURE X X X +/- 4 DEG F FROM SETPOINT X SPACE TEMPERATURE SETPOINT ADJUSTMENT X AHU-B55 FAN SPEED X X SPACE OCCUPANCY-LAB 55 & B60 X X X AHU-B55 FAN MOTOR START/STOP X X X X AHU-B55 FAN MOTOR STATUS X X FAILURE X VIA CURRENT SENSOR AHU-B55 LEAVING AIR TEMPERATURE X X X LOW LIMIT X SINGLE POINT SENSOR BASEBOARD RADIATION CONTROL VALVE POSITION COMMAND X X X FAIL LAST AHU-B55 COOLING COIL VALVE POSITION COMMAND X X X X 5 ˚F ΔT ACROSS COIL WITH VALVE COMMANDED CLOSED X NORMALLY CLOSED AHU-B55 STEAM COIL VALVE POSITION COMMAND X X X X 5 ˚F ΔT ACROSS COIL WITH VALVE COMMANDED CLOSED X FAIL LAST OUTSIDE AIR TEMPERATURE X X X OUTSIDE AIR DAMPER POSITION COMMAND X X OUTSIDE AIR DAMPER END SWITCH X FILTER RACK DIFFERENTIAL PRESSURE X X X X HIGH LIMIT X MAGNEHELIC INDICATING TRANSMITTER EAV-B60 POSITION COMMAND (CFM)X X X EAV-B60 MINIUM AIRFLOW SETPOINT (CFM)X X EAV-B60 MAXIMUM AIRFLOW SETPOINT (CFM)X X EAV-B60 FLOW FEEDBACK (CFM)X X X LOW LIMIT TEMPERATURE X X X LOW LIMIT X OUTSIDE AIR DEWPOINT X X X 1 9/13/19 ISSUE FOR 30% REVIEW 2 10/24/19 ISSUE FOR COORDINATED REVIEW 3 10/29/19 ISSUE FOR PERMIT STEAM COIL VB-1 STRAINER BLOWDOWN WITH BRASS HOSE CONNECTION, CAP WITH CHAIN LOW PRESSURE STEAM SUPPLY LOW PRESSURE CONDENSATE RETURN CV-2 V-1 (TYPICAL FOR ALL BALL VALVES) S-1 S-1 S-1 G-1 CHV-1 CHV-1 ST-2 ST-2 3" LPS (E) 2" LPS D C B AE 2" WASTE WATER PIPING 2" TAP WATER PIPING 2" ACTIVATED CARBON FILTER WATER PIPING 1/2" COMPRESSED AIR PIPING 8' - 2"8' - 6"7' - 10"PROVIDE SPEARS 1/2" UTILITY BALL VALVE, 150 PSI WATER AT 73 DEG. (PART # 2622-010). TYPICAL AT ALL PVC TO HOSE CONNECTIONS FOR WASTE WATER, TAP WATER AND ACTIVATED CARBON FILTER WATER. PROVIDE PARKER LEGRIS 2/2 IN-LINE BALL VALVE, FEMALE NPTF THREAD, INCH (PART # 4023). TYPICAL AT ALL WASTE WATER, TAP WATER AND ACTIVATED CARBON FILTER WATER. PROVIDE COILHOUSE PNEUMATICS INDUSTRIAL CONNECTORS AT COMPRESSED AIR, PVC TO HOSE CONNECTIONS AND AT HOSE END 1/4" FLEXCOIL HOSE SUPPLY RETURN ISOLATION VALVE (TYP. OF 2) BV-6 PT-2 (TYP. OF 2) AV-1 COIL NOTE: 1. PROVIDE DRAIN PAN AND TRAP ON CHILLED WATER COIL. S-1 (STRAINER BLOWDOWN WITH BRASS HOSE CONNECTION, CAP WITH CHAIN) COIL DRAIN WITH BRASS HOSE CONNECTION, CAP AND CHAIN (TYP.) CHILLED WATER COIL SHALL BE DRAINED PRIOR TO THE HEATING SEASON CV-1 PROVIDE BYPASS FOR COOLING COIL TO MAINTAIN CONTINUOUS FLOW WHEN CHILLED WATER COIL IS DRAINED DURING THE HEATING SEASON. V-1 (TYPICAL FOR ALL BALL VALVES) CD 17 30"X14" DUCT (E) REMOVE EXISTING 8" EXHAUST HOSE AND PROVIDE DUCT TRANSITION AND A 12" LENGTH OF 8" GALVANIZED ROUND DUCT FOR FUTURE EXHAUST HOSE CONNECTIONS.CORNE LL U N I V E RSI TYFOUN D E D 5681AD FACILITIES ENGINEERING N ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 FACILITY NAME Hollister Hall B55, B60, B60A, B60B, B63, B64 Lab Renovations M-401 12025236 MECHANICAL DETAILS A. FOX ALF 2046 OCTOBER 31, 2019 SCALE: NO SCALE 2 STEAM COIL PIPING DETAIL SCALE: NO SCALE 3 EXPERIMENT WATER AND PIPING INSTALLATION SCALE: NO SCALE 4 EXPERIMENTAL WATER INSTALLATION DETAIL FOR B55 SCALE: NO SCALE 1 CHILLED WATER COOILING COIL PIPING DETAIL EXPERIMENTAL WATER PIPING NOTES: 1. WASTE WATER HOSE: RED HOSE (1/4" FLEXCOIL POLYURETHANE HOSE, SERIES PU14) 2. ACTIVATED CARBON FILTER WATER HOSE: GREEN HOSE (1/4" FLEXCOIL POLYURETHANE HOSE, SERIES PU14) 3. TAP WATER PIPING: BLUE HOSE (1/4" FLEXCOIL POLYURETHANE HOSE, SERIES PU14) 4. COMPRESSED AIR hose: YELLOW HOSE (1/4" COILHOUSE PNEUMATICS NYLON COIL, 1/4" NPT SWIVEL FITTINGS, N14) 2" WASTE WATER PIPE. TIE INTO EXISTING SINK VENT AND WASTE 2" CHILLED WATER SUPPLY AND RETURN PIPING 3" STEAM PIPING EXPERIMENT WATER DROPS 1 9/13/19 ISSUE FOR 30% REVIEW 2 10/24/19 ISSUE FOR COORDINATED REVIEW 3 10/29/19 ISSUE FOR PERMIT VERIFY ALL HOSES, CONNECTORS AND VALVES WITH OWNER PRIOR TO PURCHASING. SCALE: NO SCALE 5 EXHAUST TAP DUCT CONNECTION CORNE LL U N I V E RSI TYFOUN D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 FACILITY NAME Hollister Hall B55, B60, B60A, B60B, B63, B64 Lab Renovations M-501 12025236 MECHANICAL SCHEDULES A. FOX ALF 2046 OCTOBER 31, 2019 AHU-B55 SCHEDULE TAG SERVES MANF BOD MODEL BOD AIRFLOW (CFM) ESP (IN WG) HEATING COIL COOLING COIL ELECTRICAL NOTESCAPACITY (MBH) EAT DB (F) LAT DB (F) PRESSURE (PSI)TYPE CAPACITY AIR SIDE WATER SIDE FLA V / PH / HZTOTAL (MBH) SENSIBLE (MBH) EAT DB (F) EAT WB (F) LAT DB (F) LAT WB (F) EWT (F) LWT (F)GPM WPD (FT)TYPE AHU-B55 B55, B60 TRANE CSAA010 3800 1.25 350 -5 80 2 STEAM 229 138 88 73 55 55 47 62 30.5 7.12 WATER 18.3 208/60/3 1 NOTES: 1 PROVIDE UNIT WITH DISCONNECT SWITCH. SPECS: 1 ACCEPTABLE MANUFACTURERS: ENVIRO-TEC, IEC, McQUAY, TRANE. 2 RATINGS: ARI 440, ASHRAE 33, UL 1995. 3 COOLING COIL: COPPER TUBE, ALUMINUM FINS, TESTED TO 200 PSIG, 180 DEGREE ENTERING WATER TEMPERATURE, WITH MANUAL AIR VENT AND DRAIN VALVE. 4 STEAM COIL: HEADERS SHALL BE SCHEDULE 40 STEEL OR NON-FERROUS CONSTRUCTION, PROVIDE TOP CONNECTION FOR VACUUM BREAKERS WERE APPROPRIATE. 5 FAN: DOUBLE WIDTH, DOUBLE INLET, FORWARD CURVED, CENTRIFUGAL. 6 MOTOR: ELECTRONICALLY COMMUTATED (EC). 7 DRAIN PAN: STAINLESS STEEL, COMPLYING WITH ASHRAE 62.1. 8 CABINET: BAKED ENAMEL FINISH, COLOR SELECTED BY ARCHITECT FROM STANDARD COLOR CHART , WITH 1/2-INCH COATED FIBERGLASS INSULATION. 9 FILTERS: MERV 3. 10 INSTALL FAN COIL UNITS TO COMPLY WITH NFPA 90A AND PER MANUFACTURERS INSTALLATION INSTRUCTIONS. DUCT SCHEDULE AND SPECIFICATIONS SERVICE PRESSURE CLASS SEAL CLASS LEAKAGE CLASS DUCT MATERIAL LINING DUCT INSULATION SUPPLY RECTANGULAR, EXPOSED 4" POS A 6 G90 GALVANIZED AS SPECIFIED NONE EXHAUST RECTANGULAR, EXPOSED 3" NEG A 6 G90 GALVANIZED NONE NONE GRILLE SCHEDULE MARK SERVES MANUFACTUR ER MODEL FACE SIZE (IN) NECK SIZE (IN) AIRFLOW (IN) TYPE (IN)MOUNTING NOTES SD-1 B60 TITUS TDC 24 X 24 12 X 12 600 CFM LOUVER FACE DUCT MOUNTED SD-2 B55 TITUS TDC 24 X 24 12 X 12 605 CFM LOUVER FACE DUCT MOUNTED SD-3 B64 TITUS 301RL 16 x 8 14 X 8 100 CFM LOUVER FACE WALL MOUNTED TD-1 B64 TITUS 301RL 16 X 8 16 x 8 100 CFM LOUVER FACE WALL MOUNTED TD-3 B60 TITUS TDC 24 X 24 12 X 12 600 CFM LOUVER FACE DUCT MOUNTED CONTROL VALVE SCHEDULE & SPEC TAG MANF (BOD) VALVE MODEL (BOD) ACTUATOR MODEL (BOD)SERVICE VALVE TYPE CONTROL CAPACITY VALVE SIZE (IN)CV MAX PD (PSIG)FAIL POSITION NOTES CV-1 BELIMO CCV-B238 BELIMO-AF24-SR US CHILLED WATER 2-WAY MOD 30.5 GPM 1-1/2" 19 4 FAIL CLOSED CV-2 VSI V-1 BELIMO-TR24-SR-US LOW PRESSURE STEAM 2-WAY MOD 361.55 LB/HR 1" 10.5 8 LAST PLUMBING FIXTURE SCHEDULE & SPEC TAG COMPONENTS MANUFACTURER (BOD) MODEL (BOD)DESCRIPTION MATERIAL FINISH / COLOR COLD WATER (IN) HOT WATER (IN) TEMP WATER (IN) WASTE / SANITARY (IN) VENT (IN)STANDARDS NOTES EW-1 EYE WASH GUARDIAN G1806 DECK MOUNTED, 90 DEGREE SWIVEL, RIGHT HAND MOUNTING N/A N/A 1/2 ANSI Z358.1-2004 1 S-1 LAB COUNTER TOP SINK (ADA)DURCON U05C 16"X16"X6" UNDERMOUNT SINK EPOXY RESIN BLACK ONYX 1/2" 1/2" 1-1/2" 1-1/4" 6" RIGID/SWING GOOSENECK WITH MOUNTING SHANK, SERRATED NOZZLE OUTLET, 4" METAL WRIST BLADE HANDLES, ASSE CERTIFIED VACUUM BREAKER, ASME A112.18.1, ASSE 1001, ANSI A117.1 FAUCET WATERSAVER L2224V B MIXING FAUCET BRASS CHROME DRAIN FITTING DURCON SO3-R SINK OUTLET EPOXY RESIN BLACK ONYX DRAIN TRAPWAY GEORGE FISCHER 527248 DEEP SEAL P-TRAP (9") OR DRUM TRAP POLYPRO PYLENE N/A SYPPLIES & STOPS WATTS B6000-S S QUARTER TURN BALL VALVE BRONZE N/A 2-PIECE, STANDARD PORT, 316 SS BALL AND STEM, PTFE OR RFE SEAT, MSS SP-110 EAV BOX SCHEDULE & SPECS UNIT NO. SERVES VALVE TYPE MANF BOD MODEL BOD SIZE (IN) CFM MIN ΔPt (IN WC) DAMPER POSITION NOTESMAX MIN EAV-B60 B60 EXHUAST NAILOR D30HQX 24X16 3800 1950 1 N.O. SPECS: 1 ALL DUCTWORK AND ACCESSORIES SHALL BE FABRICATED AND INSTALLED IN COMPLIANCE WITH THE LATEST ISSUE OF SMACNA'S HVAC DUCT CONSTRUCTION STANDARDS -METAL AND FLEXIBLE. 2 CONSTRUCT TEES, BENDS, AND ELBOWS WITH RADIUS OF NOT LESS THAN 1.0 TIMES THE WIDTH OF DUCT ON CENTER LINES. 3 WHERE RECTANGULAR ELBOWS ARE USED, PROVIDE AIR FOIL TYPE TURNING VANES. 4 INCREASE DUCT SIZES GRADUALLY, AND IN COMPLIANCE WITH FIGURE 4-7 OF SMACNA'S HVAC DUCT CONSTRUCTION STANDARDS -METAL AND FLEXIBLE. BRANCH CONNECTIONS SHALL BE MADE WITH A 45 DEGREE ENTRY. STRAIGHT TEES ARE NOT ACCEPTABLE. 5 SEALANTS AND GASKETS: SURFACE BURNING CHARACTERISTICS SHALL BE A MAXIMUM FLAME-SPREAD INDEX OF 25, AND MAXIMUM SMOKE-DEVELOPED INDEX OF 50 WHEN TESTED TO UL 723. 6 ALL MANUAL BALANCING DAMPERS SHALL BE PROVIDED WITH LOCKING HAND QUADRANT. 7 ACCESS DOORS SHALL BE GALVANIZED SHEETMETAL WITH INSULATION FILL AND THICKNESS AS INDICATED FOR DUCT PRESSURE CLASS. ACCESS DOORS SHALL BE INSTALLED IN THE FOLLOWING LOCATIONS: BOTH SIDES OF DUCT COILS, ADJACENT TO FIRE/SMOKE DAMPERS IN ORDER TO RESET OR REINSTALL FUSIBLE LINKS, AND AS INDICATED. 8 PROVIDE FLEXIBLE CONNECTORS TO CONNECT DUCTS TO EQUIPMENT. 9 INSTALL VOLUME DAMPERS AT POINTS ON SUPPLY, RETURN, AND EXHAUST SYSTEMS WHERE BRANCHES EXTEND FROM LARGER DUCTS. 10 REMOVE SURFACE CONTAMINANTS AND DEPOSITS FROM DUCTWORK AND EQUIPMENT PRIOR TO TESTING AND BALANCING. 11 LEAK TESTING OF DUCTWORK SHALL BE IN ACCORDANCE WITH SMACNA'S HVAC AIR DUCT LEAKAGE TEST MANUAL. ALL DUCTS DESIGNED TO OPERATE AT STATIC PRESSURES IN EXCESS OF 3-INCHES WG (POS OR NEG) SHALL BE TESTED. TEST SHALL BE WITNESSED BY A DESIGNATED CORNELL REPRESENTATIVE AND THE PROJECT ENGINEER OF RECORD. 25% OF DUCTS DESIGNED TO OPERATE AT STATIC PRESSURES 3-INCHES AND BELOW SHALL BE TESTED. TEST SHALL BE WITNESSED BY A DESIGNATED CORNELL REPRESENTATIVE AND THE PROJECT ENGINEER OF RECORD. ACCEPTANCE CRITERIA: INTERIOR SUPPLY, RETURN AND GENERAL EXHAUST: 5% SYSTEM LEAKAGE TESTED AT 1.25 TIMES THE EXPECTED OPERATING STATIC PRESSURE. ACCEPTANCE CRITERIA: INTERIOR LABORATORY EXHAUST SYSTEMS: 2% SYSTEM LEAKAGE TESTED AT 1.25 TIMES THE EXPECTED OPERATING STATIC PRESSURE. 12 ALL INSULATION AND ADHESIVE SHALL HAVE A MAXIMUM FLAME-SPREAD INDEX OF 25 AND A MAXIMUM SMOKE-DEVELOPED INDEX OF 50 WHEN TESTED IN ACCORDANCE WITH ASTM E84. DUCT LINING: ACOUSTICAL GLASS FIBER, 1", R-4, 1.5 PCF NOTES: 1 PROVIDE WITH THERMOSTATIC MIXING VALVE (BOD: GUARDIAN G3600LF) SPECS: 1 ACCEPTABLE MANUFACTURERS FOR EMERGENCY FIXTURES: ENCON, BRADLEY, GUARDIAN, HAWS, SPEAKMAN. 2 ACCEPTABLE MANUFACTURERS FOR TEMPERING VALVES: ENCON, LAWLER, BRADLEY, LAB SAFETY SUPPLY. 3 INSTALL PER MANUFACTURER'S INSTALLATION INSTRUCTIONS. SPECS: 1 ACCEPTABLE MANUFACTURERS: ANEMOSTAT, KRUEGER, NAILOR, TITUS, TRANE, PRICE 2 RATINGS: ARI 880, INDUSTRY STANDARD FOR AIR TERMINALS. 3 CONFIGURATION: PRESSURE INDEPENDENT, CONTROLLER PROVIDED AND MOUNTED IN FIELD. 4 CASING: 22 GA ZINC COATED STEEL. 5 LINING (CU STANDARD): 1/2 INCH, 1.5 PCF FIBERGLASS INSULATION COMPLYING WITH UL 181, UL 723, NFPA 90A, ASTM E84, ASTM C665, WITH PERFORATED METAL LINER. 6 AIRFLOW SENSOR: MULTI-POINT, CROSS CONFIGURATION, CENTER AVERAGING, LOCATED AT INLET OF ASSEMBLY, +/-5% ACCURACY 7 DAMPER: HEAVY GAUGE GALVANIZED STEEL, PERIPHERAL GASKET, SOLID STEEL, SHAFT, SELF LUBRICATED BEARINGS, MAX LEAKAGE OF 2% AIRFLOW WHEN TESTED FULLY CLOSED AT 3-INCH INLET STATIC PRESSURE. 8 ACCESS: REMOVABLE PANELS ON BOTTOM OR SIDE PERMITTING ACCESS TO AIR VALVE DAMPER, WITH AIRTIGHT GASKET AND QUARTER TURN LATCHES. 9 INSTALLATION: LEVEL & PLUMB, PER NFPA 90A, SMACNA DUCT CONSTRUCTION STANDARDS, AND MANUFACTURERS RECOMMENDED INSTRUCTIONS. SPEC: 1 ACCEPTABLE MANUFACTURERS: BELIMO, VSI 2 ELECTRIC INPUT: 4-20mA OR 0-10VDC 3 2-WAY VALVES: EQUAL PERCENTAGE FLOW CHARACTERISTIC 4 CONSTRUCTION: CHARACTERIZING DISK, FORGED BRASS, NICKEL PLATED BODY, STAINLESS STEEL BALL AND STEM, FIBERGLASS REINFORCED PTFE SEAT 5 RATINGS: 400 PSI PRESSURE, 0-212 F MEDIA TEMPERATURE RANGE 6 ALL CONTROL WIRING SHALL BE INSTALLED IN CONDUIT. CONTROL WIRING SHALL BE UNSPLICED FROM THE CONTROLLER TO THE SENSOR OR DEVICE. CONTROL WIRING SHALL NOT BE ROUTED IN THE SAME RACEWAY AS POWER WIRING. CONTROL WIRING SHALL BE COLOR CODED AND LABELED AT ALL POINTS OF TERMINATION. TEST EACH POINT THROUGH IT FULL OPERATING RANGE TO VERIFY THAT SAFETY AND OPERATING CONTROL SET POINTS ARE AS REQUIRED. TEST EACH CONTROL LOOP TO VERIFY STABLE MODE OF OPERATION AND COMPLIANCE WITH SEQUENCE OF OPERATION. ADJUST PID ACTIONS AS REQUIRED. THE BACS CONTRACTOR SHALL ISSUE A REPORT UPON PROJECT COMPLETION STATING THAT THE SYSTEM IS COMPLETE, HAS BEEN ADJUSTED, AND HAS HAD ALL HARDWARE AND SOFWARE FUNCTIONS VERIFIED, THAT ALL ANALOG CONTROL LOOPS ARE TUNED, AND IS OPERATING IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. ANY DEVIATIONS FROM SPECIFIED SETTINGS OR OPERATIONS NECESSITATED DURING SYSTEM ADJUSTMENT SHALL BE SPECIFICALLY NOTED. SPEC: 1 ACCEPTABLE MANUFACTURERS: ANEMOSTAT, CARNES, KRUEGER, PRICE, TITUS 2 MATERIAL: STEEL, ALUMINUM 3 FINISH: WHITE 4 INSTALL PER MANUFACTURER'S INSTALLATION INSTRUCTIONS 1 9/13/19 ISSUE FOR 30% REVIEW 2 10/24/19 ISSUE FOR COORDINATED REVIEW 3 10/29/19 ISSUE FOR PERMIT PIPING ACCESSORIES SCHEDULE AND SPECIFICATIONS TAG COMPONENT ACCEPTABLE MANUFACTURERS B.O.D. MANUFACTURER B.O.D. MODEL PRESSURE RATING SPECIFICATIONS V-1 SHUT-OFF BALL VALVE-STEAM/CHILLED WATER APOLLO, WATTS WATTS B6000-SS 300 PSIG WOG, 150 PSIG WSP MSS SP-110, 2-PIECE, STANDARD PORT, BRONZE BODY, 316 SS BALL & STEM, PTFE OR TFE SEAT S-1 STRAINER, WYE PATTERN-STEAM/CHILLED WATER APOLLO, KECKLEY, WATTS WATTS SERIES 777 200 PSIG @ 210 ˚F WOG; 125 PSIG @ 353 ˚F WSP BRONZE BODY, #20 MESH 304 STAINLESS STEEL SCREEN, THREAD OR SWEAT CONNECTION. AV-1 AIR VENT-STEAM/CHILLED WATER ARMSTRONG, BELL & GOSSETT, SARCO BELL & GOSSETT MODEL 87 150 PSIG BRASS BODY, NON-FERROUS INTERNALS G-2 PRESSURE GAUGE-STEAM ASHCROFT, TRERICE, WEKSLER, WINTERS TRERICE 700 SERIES N/A ASME B40.100, 3% ACCURACY, PHOSPHOR BRONZE BOURDON TUBE, 1/4-INCH NPT BRASS BOTTOM CONNECTION, SILICONE FILLED, STAINLESS STEEL CASE, MINIMUM 3-1/2-INCH DIAMETER, NON-REPAIRABLE, GLASS LENS, NO SNUBBERS, PIGTAIL COOLING LOOP, SELECT PRESSURE RANGE SUITABLE FOR APPLICATION CHV-1 CHECK VALVE-STEAM APOLLO, WATTS WATTS SERIES CV 200 PSIG WOG, 125 PSIG WSP 45 DEGREE SWING CHECK, HORIZONTAL FLOW, ASTM B-584 BRONZE BODY AND DISC. VB-1 VACUUM BREAKER-STEAM/CHILLED WATER ARMSTRONG, HOFFMAN, SPIRAX-SARCO HOFFMAN MODEL 62 150 PSIG @ 366 ˚F CAST IRON, BRONZE, OR STAINLESS STEEL BODY, 3/4" NPT CONNECTION. ST-2 STEAM TRAP, MAIN DRIP ARMSTRONG, HOFFMAN, SPIRAX-SARCO SPIRAX-SARCO FT14-10 125 PSIG @ 450 ˚F 1-1/2" NPT, ASTM A126 CAST IRON BODY, THREADED CONNECTION, REPLACEABLE STAINLESS STEEL FLOAT MECHANISM, STAINLESS STEEL THERMOSTATIC BELLOWS. BV-6 BALANCE VALVE, NPS 1/2 - 2 INCH-CHILLED WATER ARMSTRONG, BELL & GOSSETT, TOUR & ANDERSON BELL & GOSSETT CB SERIES, CB 2 200 PSIG @ 250 ˚F 9.0 - 40.0 GPM RANGE, BRONZE, BALL OR PLUG TYPE BODY WITH CALIBRATED ORIFICE OR VENTURI; GLASS AND CARBON FILLED TFE OR EPDM SEAT RINGS, EPDM STEM O-RING, WITH INTEGRAL SEALS FOR PORTABLE DIFFERENTIAL PRESSURE METER, WITH LEVEL HANDLE AND MEMORY STOP TO RETAIN SET POSITION. PT-2 PRESSURE/TEMPERATURE TEST PORTS-CHILLED WATER PETERSON, SISCO, TRERICE TRERICE D3769 500 PSIG @ 200 ˚F COLD/CHILLED WATER SERVICE: BRASS BODY & CAP, 1/2 NPT CONNECTION, NEOPRENE SEAT, GASKETED AND THREADED CAP WITH RETENTION CHAIN G-1 PRESSURE GAUGE-CHILLED WATER ASHCROFT, TRERICE, WEKSLER, WINTERS TRERICE 700 SERIES N/A ASME B40.100, 3% ACCURACY, PHOSPHOR BRONZE BOURDON TUBE, 1/4-INCH NPT BRASS BOTTOM CONNECTION, SILICONE FILLED, STAINLESS STEEL CASE, MINIMUM 3-1/2-INCH DIAMETER, NON-REPAIRABLE, GLASS LENS, NO SNUBBERS, SELECT PRESSURE RANGE SUITABLE FOR APPLICATION PIPE AND FITTING SCHEDULE AND SPECIFICATIONS PIPE SERVICE ABBREVIATION PIPE SIZE MATERIAL FITTINGS JOINT INSULATION CHILLED WATER CHWS&R 2-1/2" & BELOW ASTM B88, TYPE L HARD COPPER ASTM B16.22 WROUGHT COPPER ASTM B32 SOLDER YES CHILLED WATER CONDENSATE DRAIN CD ALL SIZES ASTM B88, TYPE L HARD COPPER ASTM B16.22 WROUGHT COPPER ASTM B32 SOLDER YES LOW PRESSURE STEAM LPS 2" & BELOW ASTM A53, SCHEDULE 40 BLACK STEEL ASTM A126, ASME B16.4, CAST IRON ASME B16.4 THREADED YES LOW PRESSURE STEAM LPS 2-1/2" & ABOVE ASTM A53, SCHEDULE 40 BLACK STEEL ASME B16.9, WROUGHT STEEL ASME B16.9, BUTT WELD YES LOW PRESSURE STEAM CONDENSATE LPC 2" & BELOW ASTM A53, SCHEDULE 80 BLACK STEEL ASTM A126, ASME B16.4, CAST IRON ASME B16.4, THREADED YES DOMESTIC COLD WATER DCW ALL SIZES ASTM B88, TYPE L HARD COPPER ASTM B16.22 WROUGHT COPPER ASTM B32 SOLDER YES DOMESTIC HOT WATER DHW ALL SIZES ASTM B88, TYPE L HARD COPPER ASTM B16.22 WROUGHT COPPER ASTM B32 SOLDER YES SANITARY WASTE & VENT SW / SV 2" & BELOW ASTM D 1784, 1785 & 2665 PVC SCHEDULE 40 SOILD WALL PIPE ASTM D 1784 & 2665, ASTM F 1866 SCHEDULE 40 DWV FITTING SYSTEM ASTM D 2564 SOLVENT CEMENT, ASTM F 6, ASTM F 656 PRIMER NA EXPERIMENT WATER SEE DRAWING 2" & BELOW ASTM D 1784, 1785 & 2665 PVC SCHEDULE 40 SOILD WALL PIPE ASTM D 1784 & 2665, ASTM F 1866 SCHEDULE 40 DWV FITTING SYSTEM ASTM D 2564 SOLVENT CEMENT, ASTM F 6, ASTM F 656 PRIMER NA LOW PRESSURE COMPRESSED AIR CA 1/2" & BELOW ASTM B88, TYPE L HARD COPPER BRASS COMPRESSION NA SPECS: 1 SOLDER FILLER METALS: ASTM B32, LEAD-FREE ALLOYS. INCLUDE WATER FLUSHABLE FLUX ACCORDING TO ASTM B813. 2 DIELECTRIC FITTINGS: USE FLANGES OR COUPLINGS. UNIONS ARE UNACCEPTABLE 3 INSTALL ESCUTCHEONS FOR PENETRATIONS OF WALLS, CEILING, AND FLOORS 4 INSTALL SLEEVES FOR PIPES PASSING THROUGH CONCRETE AND MASONRY WALLS, GYPSUM-BOARD PARTITIONS, AND CONCRETE FLOOR AND ROOF SLABS. 5 INSTALL PIPING SYSTEMS TO FACILITATE SERVICE, MAINTENANCE AND REPAIR OR REPLACEMENT OF COMPONENTS. 6 ALL INSULATION AND ADHESIVE SHALL HAVE A MAXIMUM FLAME-SPREAD INDEX OF 25 AND A MAXIMUM SMOKE-DEVELOPED INDEX OF 50 WHEN TESTED IN ACCORDANCE WITH ASTM E84. INSULATE SYSTEMS PER LOCAL AND STATE CODES. 7 PROVIDE ALUMINUM OR PVC FIELD APPLIED JACKETING IN HIGH TRAFFIC AREAS AND ALL EXPOSED PIPING BELOW 8 FEET. 8 MAINTAIN INDICATED FIRE RATING OF WALLS, PARITIONS, CEILINGS, AND FLOORS AT PIPE PENETRATIONS. SEAL PIPE PENETRATIONS WITH FIRESTOP MATERIALS 9 INSTALL DRAINS, CONSISTING OF A TEE FITTING, NPS 3/4 BALL VALVE, AND SHORT NPS 3/4 THREADED NIPPLE AT LOW POINTS IN PIPING SYSTEM AS REQUIRED FOR DRAINAGE. 10 INSTALL MANUAL AIR VENT AT HIGH POINT IN PIPING SYSTEM AS REQUIRED FOR BLEEDING SYSTEM OF AIR. 11 INSTALL UNIONS IN PIPING, NPS 2 AND SMALLER, ADJACENT TO VALVES, AT FINAL CONNECTIONS OF EQUIPMENT, AND ELSEWHERE AS INDICATED 12 INSTALL STRAINERS ON INLET SIDE OF CONTROL VALVES, IN-LINE PUMP AND ELSEWHERE AS INDICATED. INSTALL NIPPLE AND BALL VALVE IN BLOWDOWN CONNECTION. 13 INSTALL PORTS FOR PRESSURE GAGES AND THERMOMETERS AT COIL INLET AND OUTLET CONNECTIONS. 14 PROVIDE PIPE LABLES AND DIRECTIONAL ARROWS ON ALL NEW PIPING SYSTEMS. LABELS SHALL BE PRINTED PLASTIC WITH CONTACT-TYPE, PERMANENT ADHESIVE BACKING. LETTERS SHALL BE 1/4-INCH IF VIEWING DISTANCE IS LESS THAN 24 INCHES, 1/2-INCH FOR VIEWING DISTANCES UP TO 72 INCHES, AND PROPORTIONATELY LARGER LETTERING FOR GREATER VIEWING DISTANCES. 15 TESTING OF HYDRONIC SYSTEMS: FILL SYSTEM WITH AMBIENT TEMPERATURE WATER. USE VENTS INSTALLED AT HIGH POINTS OF SYSTEM TO RELEASE AIR. USE DRAINS INSTALLED AT LOW POINTS FOR COMPLETE DRAINING OF TEST LIQUID. ISOLATE EXPANSION TANKS AND DETERMINE THAT HYDRONIC SYSTEM IS FULL OF WATER SUBJECT PIPING SYSTEM TO HYDROSTATIC TEST PRESSURE THAT IS NOT LESS THAN 1.5 TIMES THE SYSTEM WORKING PRESSURE. TEST PRESSURE SHALL NOT EXCEED MAXIMUM PRESSURE FOR DEVICE IN THE SYSTEM UNDER TEST. AFTER HYDROSTATIC TEST PRESSURE HAS BEEN APPLIED FOR AT LEAST 10 MINUTES, EXAMINE PIPING, JOINTS, AND CONNECTIONS FOR LEAKAGE. ELIMINATE LEAKS BY TIGHTENING, REPAIRING, OR REPLACING COMPONENTS, AND REPEAT HYDROSTATIC TEST UNTIL THERE ARE NO LEAKS. ARRANGE FOR INSPECTION BY FACILITIES MANAGEMENT PIPE SHOP. 16 INSTALL STEAM SUPPLY PIPING AT A MINIMUM UNIFORM GRADE OF 0.2 PERCENT DOWNWARD IN DIRECTION OF STEAM FLOW. INSTALL CONDENSATE RETURN PIPING AT A MINIMUM UNIFORM GRADE OF 0.4 PERCENT DOWNWARD IN DIRECTION OF CONDENSATE FLOW. REDUCE STEAM PIPE SIZES USING ECCENTRIC REDUCER FITTINGS INSTALLED WITH LEVEL SIDE DOWN. AIR DUCT ACCESSORIES TAG ACTUATOR MANUFACTURER (BOD) MANUFACTURER (BOD) MODEL (BOD) SIZE (IN)MATERIAL TYPE FLOW (CFM) VELOCITY (FT/MIN) PRESSURE DROP (IN WG) LEAKAGE NOTESCLASS (CFM/FT² @ 1" PD) L-1 N/A GREENHECK ESD-435 44 X 44 6063-T5 ALUMINUM DRAINABLE DESIGN 3800 524 0.04 N/A N/A CD-1 BELIMO GREENHECK VCD-23 44 X 44 GALVANIZED OPPOSED BLADE 3800 - - 1A 3 VD-1 N/A RUSKIN MDRS25 SEE DWGS GALVANIZED OPPOSED BLADE SEE DWGS - - - - CORNE LL U N I V E RSI TYFOUN D E D 5681AD FACILITIES ENGINEERING ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 HOLLISTER HALL Hollister Hall B55, B60, B60A, B60B, B63, B64 Lab Renovations E-001 12025236 GENERAL NOTES AND SYMBOL LEGENDS C. WAYMAN CMW 2046 OCTOBER 31, 2019 GENERAL ELECTRICAL NOTES 1.0 ELECTRICAL SCHEMATICS INDICATED ON CONTRACT DOCUMENTS ARE DIAGRAMMATIC. IT IS NOT THE INTENT TO SHOW EXACT OR MOST EFFICIENT ROUTING. VERIFY ALL DIMENSIONS AND FIELD CONDITIONS ON SITE. ANY CONFLICTS BETWEEN CONSTRUCTION DOCUMENTS AND FIELD CONDITIONS SHALL BE BROUGHT TO CORNELL'S PROJECT MANAGER FOR RESOLUTION BEFORE WORK PROCEEDS. 2.0 ASSURE PUBLIC AND WORKER SAFETY AT ALL TIMES. PROTECT ADJOINING AREAS FROM DAMAGE AND DUST. REMOVE ALL DEBRIS FROM SITE AND DISPOSE OF WASTE MATERIAL IN A SAFE MANNER. KEEP THE PREMISES FREE OF DEBRIS FROM THE EXECUTION OF WORK. DELIVER A FINAL PRODUCT THAT IS CLEAN AND OPERABLE. 3.0 FIRE STOP ELECTRICAL PENETRATIONS THROUGH FIRE RATED WALLS AND/OR FLOORS WITH MATERIAL EQUAL IN RATING TO THE CONSTRUCTION OF THE MATERIAL PENETRATED. 4.0 WORK SHALL BE COMPLETED AS SPECIFIED AND INDICATED ON CONTRACT DOCUMENTS. ANY SUGGESTED ALTERNATE MANUFACTURER OR METHOD OF INSTALLATION SHALL BE SUBMITTED TO PROJECT ENGINEER FOR APPROVAL PRIOR TO ORDERING ANY MATERIALS OR COMMENCING EXECUTION OF WORK. 5.0 GROUNDING SHALL BE IN STRICT ACCORDANCE WITH NEC ARTICLE 250. PROVIDE EQUIPMENT GROUND CONDUCTOR WITH EACH BRANCH CIRCUIT INDICATED ON CONTRACT DOCUMENTS. EQUIPMENT GROUND CONDUCTOR SHALL BE ROUTED WITH ASSOCIATED PHASE CONDUCTORS. 6.0 PROVIDE A NEW TYPED PANELBOARD DIRECTORY FOR EACH PANELBOARD. LABEL ALL NEW DEVICE FACEPLATES WITH SOURCE AND CIRCUIT NUMBER. PROVIDE PERMANENT LABEL ON SWITCHING DEVICES INDICATING EQUIPMENT SERVICE AND INVENTORY NUMBERS. COORDINATE EQUIPMENT INVENTORY NUMBERS WITH CORNELL UNIVERSITY'S MECHANICAL SHOP, 255-8667. 7.0 CIRCUITS RATED 20-AMP, 120 VOLT SHALL CONTAIN SEPARATE NEUTRAL CONDUCTORS. 8.0 CONDUCTORS SHALL BE A MINIMUM OF 12AWG, STRANDED COPPER, 600VAC, 90 DEGREE C, TYPE THHN/THWN-2 FOR DRY AREAS AND XHHW/THWN-2 FOR WET AREAS. 9.0 CONDUITS SHALL BE A MINIMUM OF 3/4 INCHES DIAMETER. CONDUITS SHALL BE ELECTRICAL METALLIC TUBING (EMT) AND SURFACE MOUNTED UNLESS NOTED OTHERWISE. 10.0 AIC RATING OF NEW CIRCUIT BREAKERS SHALL MATCH RATING OF RESPECTIVE PANELBOARD. SIZE AS INDICATED. 11.0 PROVIDE PULL STRING THROUGH NEW CONDUIT AND BOXES. PROVIDE SUPPORT HANGERS FOR CONDUIT AS NEEDED. 12.0 INSTALL RACEWAY SYSTEMS ENSURING PROPER ACCESS TO EQUIPMENT AND DEVICES AND WITH SUFFICIENT SPACE TO PERFORM ROUTINE MAINTENANCE AND REPAIR. RACEWAYS THAT ARE NOT INSTALLED WITH THIS REQUIREMENT IN MIND SHALL BE RELOCATED AT NO EXPENSE TO THE UNIVERSITY UNTIL DEFICIENCIES ARE CORRECTED. ELECTRICAL SCOPE OF WORK 1.0 PROVIDE NEW TELEPOWER POLES, RECEPTACLES, AND DATA JACKS TO SUPPORT THE LAB RECONFIGURATIONS IN BASEMENT B60 AND B60A. 2.0 PROVIDE NEW RECEPTACLES IN 2ND FLOOR ROOM 254. ELECTRICAL LEGEND LIGHTING LEGEND MOTOR 1'x4' LUMINAIRE HARDWIRED EQUIPMENT CONNECTION P-1A12 HOMERUN TO PANEL P-1A, CIRCUIT #12. FED FROM 20A -1P BREAKER IS INTENDED UNLESS NOTED OTHERWISE. RUN GREEN WIRE GROUND FOR ALL CIRCUITS. PROVIDE ONE GROUND PER CIRCUIT. EMERGENCY POWER OFF (EPO) GROUND ROD ELECTRODE DUPLEX RECEPTACLE WITH GFCI PROTECTION DUPLEX RECEPTACLE WITH AFCI PROTECTION QUAD RECEPTACLE LINETYPES LEGEND SPECIAL RECEPTACLE5-30R PANELBOARD JUNCTION BOX B = INSTALLED IN BASEBOARD TR = INSTALLED IN WOOD TRIM/CASEWORK/WAINSCOTT SR = SURFACE RACEWAY WP = WEATHERPROOF AC = AIR CONDITIONER X DUPLEX RECEPTACLE: DOUBLE DUPLEX RECEPTACLE MOTOR STARTER J 2'x4' LUMINAIRE CEILING MOUNTED LUMINAIRE EM LIGHTING BATTERY UNIT COMBO EXIT SIGN/EM LIGHTING BATTERY UNIT SINGLE FACE, WALL MOUNT EXIT SIGN DOUBLE FACE, WALL MOUNT EXIT SIGN SINGLE FACE, CEILING MOUNT EXIT SIGN DOUBLE FACE, CEILING MOUNT EXIT SIGN LIGHT SWITCH: SAFETY SWITCH (NON-FUSED) SAFETY SWITCH (FUSED) X 3 = 3-WAY SWITCH 4 = 4-WAY SWITCH D = DIMMER SWITCH O = WALL SWITCH OCCUPANCY SENSOR V = WALL SWITCH VACANCY SENSOR W = WIRELESS SWITCH S = WIRELESS SCENE SWITCH WIRELESS OCCUPANCY SENSOR WIRELESS DAYLIGHT SENSOR OS W DS 1'x2' LUMINAIRE FIRE ALARM LEGEND FIRE ALARM CONTROL PANEL BATTERY CABINET WATER FLOW SWITCH MUXPAD REMOTE ANNUNCIATOR D = DUCT SMOKE DETECTOR R = RELAY BASE BR = BEAM RECEIVER BT = BEAM TRANSMITTER SB = SOUNDER BASE SMOKE DETECTOR: TAMPER SWITCH AUDIBLE NOTIFICATION APPLIANCE FACP BATT MUX FAA NAC PANELNAC MANUAL PULL STATIONF S X F = FIXED TEMPERATURE R = RATE OF RISE R/F = COMBINATION RISE/FIXED TEMPERATURE HEAT DETECTOR: H X CARBON MONOXIDE DETECTORCO AM F XXcd C FS F S XXcd C TS ADDRESSABLE MODULE XXcd = CANDELA C = CEILING COMBO A/V NOTIFICATION APPLIANCE: XXcd = CANDELA C = CEILING VISUAL NOTIFICATION APPLIANCE: SUPPRESSION SYSTEM ELECTRICAL ABBREVIATIONS AC AIR CONDITIONER AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE AFI ARC FAULT INTERRUPTER AMM ADDRESSABLE MONITOR MODULE AOM ADDRESSABLE OUTPUT MODULE ARB AUXILIARY RELAY BOARD ATS AUTOMATIC TRANSFER SWITCH B BASEBOARD BKR BREAKER C CONDUIT CD CANDELA CKT CIRCUIT CR CONTROL RELAY EC ELECTRICAL CONTRACTOR EMT ELECTRICAL METALLIC TUBING EPO EMERGENCY POWER OFF STATION FAA FIRE ALARM ANNUNCIATOR PANEL FACP FIRE ALARM CONTROL PANEL FSD FIRE SMOKE DAMPER GAA GENERATOR ALARM ANNUNCIATOR GFI GROUND FAULT INTERRUPTER GND GROUND HP HORSEPOWER KW KILOWATT LC LIGHTING CONTACTOR LFMC LIQUID TIGHT FLEXIBLE METALLIC CONDUIT LTG LIGHTING MCB MAIN CIRCUIT BREAKER MLO MAIN LUG ONLY MTS MANUAL TRANSFER SWITCH NAC NOTIFICATION APPLIANCE CIRCUIT NIC NOT IN CONTRACT OE OVERHEAD ELECTRIC PC PHOTOCELL PM PLUGMOLD PP POWER PANEL PVC POLYVINYL CHLORIDE CONDUIT RGS RIGID GALVANIZED STEEL CONDUIT SR SURFACE RACEWAY ST SHUNT TRIP TM THERMAL MAGNETIC TR TRIM/CASEWORK/WAINSCOTT TSP TWISTED SHIELDED PAIR TYP TYPICAL UE UNDERGROUND ELECTRIC UON UNLESS OTHERWISE NOTED UPS UNINTERRUPTIBLE POWER SUPPLY V VOLTS VA VOLT AMPS WP WATERPROOF UNDERGROUND ELECTRICUE UNDERGROUND LIGHTINGUL OVERHEAD ELECTRICOE TO BE PROVIDED DEMOLITION / TO BE RELOCATED EXISTING TO REMAIN UNDERGROUND TELCOUC MOUNTING HEIGHTS CARD READER 48" TOP OF BOX LIGHT SWITCH 48" TOP OF BOX RECEPTACLE 18" TOP OF BOX DATA OUTLET 18" TOP OF BOX TV OUTLET 84" TOP OF BOX PHONE OUTLET 48" TOP OF BOX SAFETY SWITCH 60" CENTERLINE OF HANDLE MOTOR STARTER 60" CENTERLINE OF HANDLE PANELBOARD 72" TOP OF PANELBOARD MANUAL PULL STATION 48" OPERABLE HANDLE NOTIFICATION APPLIANCE 80" BOTTOM OF LENS DOOR HOLD OPEN COORDINATE IN FIELD EM BATTERY UNIT 96" BOTTOM OF UNIT EM REMOTE UNIT 102" BOTTOM OF UNIT EXIT SIGN 96" BOTTOM OF UNIT LIGHT POLE WITH LED LUMINAIRES, REFER TO PLANS FOR NUMBER AND CONFIGURATION OF HEADS GENERAL ELECTRICAL DEMOLITION NOTES 1.0 ELECTRICAL EQUIPMENT SHOWN DASHED ON DEMOLITION DRAWINGS, INCLUDING ASSOCIATED ANCHORS, SUPPORTS, STRAPS, BOXES, FITTINGS, AND OTHER APPURTENANCES NOT SHOWN, SHALL BE DISCONNECTED AND REMOVED. REMOVE ASSOCIATED BRANCH CIRCUITRY TO SOURCE, UNLESS NOTED OTHERWISE. 2.0 EXISTING RACEWAYS AND DEVICE BACKBOXES NOT INTERFERRING WITH NEW WORK SHALL BE REUSED WHERE POSSIBLE. 3.0 PROVIDE JUNCTION BOXES, RACEWAYS, AND WIRING TO MODIFY/EXTEND EXISTING SYSTEMS AND CIRCUITS FED DOWNSTREAM OF ELECTRICAL EQUIPMENT SHOWN TO BE DEMOLISHED. 4.0 CUT DEMOLISHED CONDUITS INSTALLED THRU WALLS AND FLOORS FLUSH WITH THE SURFACE AND PATCH PENETRATIONS (FIRESTOP IF LOCATED ON A FIRE RATED SURFACE). PATCH AND PAINT SURFACES IN EXPOSED AREAS TO MATCH SURROUNDING MATERIALS, FINISHES, AND COLORS. 5.0 PROVIDE BLANK COVERPLATES ON UNUSED BACKBOXES REMAINING FROM DEMOLITION NOT SPECIFIED TO BE INFILLED. 6.0 EXISTING EQUIPMENT SHOWN TO REMAIN SHALL BE PROTECTED DURING CONSTRUCTION. EQUIPMENT CONNECTION SCHEDULE LABEL DESCRIPTION ROOM NO. PANEL RATING (kW, W, VA, A, HP)VOLTAGE PHASE WIRE & CONDUIT STARTER DISCONNECT NOTES ADDITIONAL REQUIREMENTSTYPE LOC BY ENC AUX BY RATING LOC ENC AHU-B55 AIR HANDLER B55 SEE DWG 18.3-FLA 208 3 3#10, 1#10G, 3/4" EMT - UNIT MFR - - MFR - UNIT - 1,4 NOTES: 1. MAKE CONNECTION TO EQUIPMENT.A. START-STOP IN COVER. 2. INSTALL MOTOR STARTER FURNISHED BY OTHERS.B. HAND-OFF-AUTO IN COVER. 3. MAKE CONNECTIONS TO CONTROLS.C. PILOT LIGHT IN COVER. 4. FIELD CONTROL WIRING BY OTHERS.D. AUXILIARY CONTACTS. 5. RUN FEED THRU CONTACTOR. CONTROL FROM FAN SHUTDOWN RELAY. E. CONTROL CIRCUIT TRANSFORMER. 6. PROVIDE DUCT SMOKE DETECTOR.F. TWO-SPEED MOTOR CONTROLLER. 7. PROVIDE GFI RECEPTACLE AT UNIT. CIRCUIT TO NEAREST 120V CIRCUIT. G. KEY OPERATED - UP/DOWN OR OPEN/CLOSE. 8. WIRE THRU T-STAT THEN TO MOTOR. ELECTRICAL SPECIFICATIONS ITEM DESCRIPTION MANUFACTURER MODEL COLOR SUBMITTAL NOTES 1 PANELBOARDS SQUARE D TYPE NQ GRAY SHOP DWG NEMA 1, SURFACE MOUNT, DOOR-IN-DOOR TRIM, TYPED DIRECTORY, SEE PANEL SCHEDULE 2 TELEPOWER POLES WIREMOLD 30TP-4V BY OWNER PRODUCT DATA CEILING HEIGHT IS 12'-11" 3 DUPLEX RECEPTACLES HUBBELL 5352AG GRAY PRODUCT DATA 20A, 120V COMMERCIAL INDUSTRIAL GRADE 4 LIGHT SWITCHES HUBBELL HBL1221GY GRAY PRODUCT DATA 20A, 120V HEAVY DUTY INDUSTRIAL GRADE 5 COVERPLATES VARIOUS - STAINLESS STEEL PRODUCT DATA 6 ACCESS CONTROL CARD READERS VARIOUS - - - COMPLY WITH CORNELL DESIGN STANDARD 281316 7 ACCESS CONTROL DUAL READER INTERFACES LENEL LNL-1320 - - COMPLY WITH CORNELL DESIGN STANDARD 281316 8 ACCESS CONTROL POWER SUPPLY LENEL LNL-OLS120ACTXP2 - -COMPLY WITH CORNELL DESIGN STANDARD 281316 9 WIRES AND CONDUCTORS VARIOUS - - PRODUCT DATA COMPLY WITH CORNELL DESIGN STANDARD 260519 10 RACEWAYS VARIOUS - - PRODUCT DATA COMPLY WITH CORNELL DESIGN STANDARD 260533 11 BUCK & BOOST TRANSFORMER LARSON MT-BBT-208V-240V-93.7A GRAY PRODUCT DATA 22.1-KVA, 208V PRI, 240V SEC, NEMA 1 ENCLOSURE 12 250V, 30A RECEPTACLE HUBBELL HBL9330 BLACK PRODUCT DATA 2-POLE, 3-WIRE GROUNDING, 30A RATED, INDUSTRIAL GRADE 1 9/12/19 ISSUE FOR DD REVIEW 2 10/31/19 ISSUE FOR PERMIT (8)(8)(8)(8) DH DH DH DH DH DH DH 1 2 1 1 1 3 4 4 4 4 5 PANEL BH2A-6 PANEL BH2B-6 PANEL BL1B-15 PANEL BL1A-15 6 7 TYP B60 B55 B00CA B00UC B64 B66 B62B62A B60B B56A B56 CORNE LL U N I V E RSI TYFOUN D E D 5681AD FACILITIES ENGINEERING N ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 HOLLISTER HALL Hollister Hall B55, B60, B60A, B60B, B63, B64 Lab Renovations E-101 12025236 BASEMENT - ELECTRICAL DEMOLITION PLAN C. WAYMAN CMW 2046 OCTOBER 31, 2019 #E-101 KEYED DEMOLITION NOTES 1 DISCONNECT AND REMOVE SURFACE MOUNTED BOXES, RECEPTACLES, AND RACEWAYS AS SHOWN. 2 DISCONNECT AND REMOVE SAFETY SWITCH AND BRANCH CIRCUITRY TO SOURCE. 3 DISCONNECT AND REMOVE J-BOX AND ASSOCIATED DATA CABLING. 4 DISCONNECT AND REMOVE DATA CABLING AND ALL ASSOCIATED RACEWAYS AND BOXES. 5 DISCONNECT AND REMOVE LIGHT SWITCH. TAG EXISTING LIGHTING CIRCUITRY FOR REUSE. 6 DISCONNECT BRANCH CIRCUITRY TO MAKE-UP AIR UNIT AND REMOVE TO SOURCE. REVISE PANELBOARD SCHEDULE ACCORDINGLY. 7 EXISTING RECEPTACLES AND RACEWAYS TO REMAIN. PROTECT DURING CONSTRUCTION AND PREPARE TO REFEED. SCALE: 3/16"=1'-0" 0 2 4 6 12 SCALE:3/16" = 1'-0"1 BASEMENT - ELECTRICAL DEMOLITION PLAN 1 9/12/19 ISSUE FOR DD REVIEW 2 10/31/19 ISSUE FOR PERMIT CR CR (2) (2) (2) (2) (2) DH DH DH DH DH DH DH 5 3 4 6 7 PANEL BH2A-6 PANEL BH2B-6 PANEL BL1B-15 PANEL BL1A-15 7 B55 B00CA B64 B62B62A B60 B56 B66 B60B B56A 3LNP-B1- 9LNP-B1-4LNP-B1- (2)(2)(2) 14LNP-B1-17LNP-B1-19LNP-B1-16LNP-B1- 10LNP-B1- 13LNP-B1- 11LNP-B1- 1LNP-B1- 12LNP-B1- 15LNP-B1- 18LNP-B1- 21LNP-B1- 7LNP-B1- 22LNP-B1- 20LNP-B1- 25LNP-B1- 24LNP-B1- 26LNP-B1- 23LNP-B1- 28LNP-B1- PANEL LNP-B1 1 2 8 8 12 2LNP-B1- 10 37,39,41LNP-B1- AHU-B55 5LNP-B1- 13 12 14 15 4 4 4 3 3 3 3 3 3 7 9 11 48" 6,8LNP-B1-16 17 240V, 1-PHASE TABLETOP FURNACE 4#1, 1#6G, 1.25" EMT EXISTING PANEL BL1A-15 208Y/120V, 3-PHASE, 4-WIRE 400A MLO SQUARE D TYPE NQOD CAT NO. 12164281940680001-1 REMOVE 40A/3P BREAKER AT #37/39/41 AND PROVIDE A 125A/3P BREAKER WITH 22-kA AIC RATING UL LISTED PANEL LNP-B1 1 2 15 NEMA 6-30 RECEPTACLE (ROOM B64) TABLE FURNACE 22.1-KVA BUCK & BOOST TRANSFORMER (208V PRI, 240V SEC) 2#10, 1#10G, 3/4" EMT 2#10, 1#10G, 3/4" EMT 16 17 NOTES: 1.THE FOLLOWING CABLES ARE FOR THE CORRESPONDING DEVICES: 1.1 6#22AWG STANLEY 2S22062GN5 (SHIELDED) -CARD READER 1.2 4#18AWG STANLEY 2U18042BK5 -DOOR STRIKE 1.3 2#18AWG STANLEY 2S18022RD5 -DOOR CONTACT 1.4 INSTALL IN 3/4" EMT 2.PROVIDE CARD READER, CONDUIT, WIRE, AND PROGRAMMING. REFER TO AND COMPLY WITH CORNELL DESIGN STANDARD 281316. NEW LENEL DUAL READER INTERFACE + POWER SUPPLY PROVIDE 3/4" CONDUIT WITH #22/2 TSP AND #18/2 THHN TO DOOR CONTROLLER IN RM. 100UB ROOM B55 CARD READER DOOR STRIKE DOOR CONTACT CARD READER DOOR STRIKE DOOR CONTACT DOOR B55 DOOR B60 J J 120VAC E-102 KEYED CONSTRUCTION NOTES 1 REMOVE BREAKER AT #37/39/41 AND PROVIDE A 125A/3-POLE SQUARE D CIRCUIT BREAKER RATED FOR 22-kA AIC. BREAKER MUST BE UL LISTED COMPATIBLE WITH THE EXISTING PANELBOARD. MODIFY PANELBOARD SCHEDULE ACCORDINGLY. 2 PROVIDE PANELBOARD LNP-B1 SIMILAR TO A SQUARE D TYPE NQ. CIRCUIT ALL LOADS AS SHOWN TO PROPERLY BALANCE THE LOADS. PROVIDE A TYPED PANELBOARD DIRECTORY. REFER TO THE PANELBOARD AND SPECIFICATION SCHEDULES FOR ADDITIONAL INFORMATION. 3 PROVIDE A STEEL TELEPOWER POLE AT ALL LOCATIONS SHOWN. PROVIDE EACH WITH (2) 120V/20A DUPLEX RECEPTACLES. COLOR BY OWNER. REFER TO THE SPECIFICATIONS SCHEDULE FOR ADDITIONAL INFORMATION. PROVIDE 2#12, 1#12G, 3/4" EMT BRANCH CIRCUITRY. 4 PROVIDE DOUBLE DUPLEX RECEPTACLES AT 16" AFF AT LAB TABLES AS SHOWN. PROVIDE WITH 4"x4" FLUSH BOXES WITH MUD RINGS. PROVIDE 2#12, 1#12G, 3/4" EMT BRANCH CIRCUITRY. 5 PROVIDE A DUPLEX RECEPTACLE AT 16" AFF AT 3D PRINTERS AS SHOWN. PROVIDE WITH 4"x4" FLUSH BOXES WITH MUD RINGS. PROVIDE 2#12, 1#12G, 3/4" EMT BRANCH CIRCUITRY. 6 PROVIDE A NEW LIGHT SWITCH AND MODIFY/EXTEND EXISTING LIGHTING CIRCUITRY TO NEW SWITCH LOCATION. INSTALL TOP OF SWITCH AT 48" AFF. 7 REFEED EXISTING DUPLEX RECEPTACLES AS SHOWN. CIRCUIT WITH 2#12, 1#12G, 3/4" EMT. 8 PROVIDE CARD READER AND INSTALL TOP OF READER AT 48" AFF. PROVIDE DOOR CONTACTS. PROVIDE A 4"x4" J-BOX ABOVE DOOR WITH 3/4" EMT TO THE DUAL READER INTERFACE IN B55. PROVIDE ALL CARD READER, DOOR CONTACT, AND DOOR HARDWARE WIRING. COORDINATE ALL ACCESS CONTROL WORK WITH KEVIN BARNHART. 9 PROVIDE AN ACCESS CONTROL POWER SUPPLY AND INSTALL ON WALL NEAR CEILING. CIRCUIT WITH 2#12, 1#12G, 3/4" EMT. COORDINATE ALL ACCESS CONTROL WORK WITH KEVIN BARNHART. 10 PROVIDE ACCESS CONTROL DUAL READER INTERFACE ON W ALL NEAR CEILING. CIRCUIT TO THE ADJACENT ACCESS CONTROL POWER SUPPLY. COORDINATE ACCESS CONTROL WORK WITH KEVIN BARNHART. 11 PROVIDE 3/4" EMT BETWEEN ACCESS CONTROL DUAL READER INTERFACE IN ROOM B55 TO THE DOOR CONTROLLER LOCATED IN FIRST FLOOR ROOM 100UB. PROVIDE KEVIN BARNHART APPROVED COMMUNICATIONS CABLING BETW EEN THE DUAL READER INTERFACE AND THE DOOR CONTROLLER. CONTRACTOR TO FIELD VERIFY THE ROUTING AND PROVIDE ALL NECESSARY COREDRILLING AND FIREPROOFING. 12 PROVIDE A SURFACE MOUNT J-BOX FOR WIRELESS ACCESS POINT BY OTHERS. PROVIDE 3/4" EMT FROM EACH LOCATION TO THE CIT DATA ROOM LOCATED IN SECOND FLOOR ROOM 224. PROVIDE A CIT APPROVED CAT6 CABLE FOR EACH LOCATION. CONTRACTOR TO FIELD VERIFY THE ROUTING AND PROVIDE ALL NECESSARY COREDRILLING AND FIREPROOFING. DATA JACKS, COVERPLATES, CABLE TESTING, TERMINATIONS, CABLE MANAGEMENT, AND WIRELESS ACCESS POINTS BY OTHERS. COORDINATE THE EXACT LOCATION AND MOUNTING HEIGHT WITH CIT PRIOR TO ROUGH-IN. COORDINATE ALL WORK WITH CIT. 13 PROVIDE 2#12, 1#12G, 3/4" EMT TO HVAC BUILDING MANAGEMENT SYSTEM PANEL. LOW-VOLTAGE WIRING BETWEEN HVAC EQUIPMENT BY OTHERS. 14 CIRCUIT AHU-B55 AS SPECIFIED IN THE EQUIPMENT CONNECTION SCHEDULE. ALL CONTROL WIRING BY OTHERS. 15 PROVIDE FEEDER AND INSTALL ON EXPOSED CEILING. PAINT CONDUIT TO MATCH SURROUNDING SURFACES. REFER TO THE ONE-LINE DIAGRAM FOR ADDITIONAL INFORMATION. 16 PROVIDE A BUCK & BOOST TRANSFORMER. REFER TO THE ELECTRICAL SPECIFICATIONS FOR ADDITIONAL INFORMATION. 17 PROVIDE A NEMA 6-30 RECEPTACLE WITH A METAL, SURFACE-MOUNT BOX. REFER TO THE ELECTRICAL SPECIFICATIONS FOR ADDITIONAL INFORMATION. # SCALE: 3/16"=1'-0" 0 2 4 6 12CORNE LL U N I V E RSI TYFOUN D E D 5681AD FACILITIES ENGINEERING N ARCHIVE BAR CODEITHACA, NEW YORK ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: DATE: FACILITY: DESIGN: DRAWN: WWW.FCS.CORNELL.EDU IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT THEIR SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY THEIR SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING REVISIONS ARCHITECTURAL, STRUCTURAL, CIVIL, ENVIRONMENTAL, MECHANICAL, AND ELECTRICAL ENGINEERING 201 HUMPHREYS SERVICE BLDG ITHACA, NEW YORK 14853-3701 HOLLISTER HALL Hollister Hall B55, B60, B60A, B60B, B63, B64 Lab Renovations E-102 12025236 ELECTRICAL NEW WORK PLANS C. WAYMAN CMW 2046 OCTOBER 31, 2019 SCALE:3/16" = 1'-0"1 BASEMENT - ELECTRICAL NEW WORK PLAN ACCESS CONTROL 1000 VA 100.00% 1000 VA TELEPOWER POLES 8640 VA 50.00% 4320 VA TOTAL DEMAND AMPS:93 A 3D PRINTER 16800 VA 100.00% 16800 VA TOTAL CONN AMPS:117 A LAB EQUIPMENT 4000 VA 100.00% 4000 VA TOTAL DEMAND:33500 VA RECEPTACLES 5400 VA 50.00% 2700 VA TOTAL CONN LOAD:42138 VA HVAC 7079 VA 75.00% 5310 VA LOAD CLASSIFICATION CONN LOAD DEMAND FACTOR EST DEMAND PANEL TOTALS TOTAL AMPS:113 A 113 A 126 A TOTAL LOAD:13546 VA 13530 VA 15069 VA 41 -- -- --2196 0 1 20 SPARE 42 39 -- -- -- 2196 0 1 20 SPARE 40 37 AHU-B55 30 3 2196 0 1 20 SPARE 38 35 SPACE -- --0 0 1 20 SPARE 36 33 SPACE -- -- 0 0 1 20 SPARE 34 31 SPARE 20 1 0 0 1 20 SPARE 32 29 SPARE 20 1 0 0 1 20 SPARE 30 27 SPARE 20 1 0 1680 1 20 RCPT: B60 3D PRINTER 28 25 RCPT: B60 3D PRINTER 20 1 1680 1680 1 20 RCPT: B60 3D PRINTER 26 23 RCPT: B60 3D PRINTER 20 1 1680 1680 1 20 RCPT: B60 3D PRINTER 24 21 TELEPOWER POLE: B60 20 1 1680 1680 1 20 RCPT: B60 3D PRINTER 22 19 TELEPOWER POLE: B55 20 1 1440 1680 1 20 RCPT: B60 3D PRINTER 20 17 TELEPOWER POLE: B55 20 1 1440 1680 1 20 TELEPOWER POLE: B60 18 15 TELEPOWER POLE: B60 20 1 1440 1440 1 20 TELEPOWER POLE: B55 16 13 RCPTS: B60 20 1 720 1440 1 20 TELEPOWER POLE: B55 14 11 RCPTS: B60 20 1 720 1440 1 20 TELEPOWER POLE: B60 12 9 RCPTS: B55 20 1 1080 720 1 20 RCPTS: B60 10 7 RCPT: B60 3D PRINTER 20 1 1680 0 -- -- -- 8 5 B55: BMS PANEL 20 1 500 4000 2 30 B64: FURNACE (240V) 6 3 RCPTS: B55 20 1 720 1080 1 20 RCPTS: B55 4 1 RCPTS: B60 20 1 360 1000 1 20 CARD ACCESS: B55 2 CKT DESCRIPTION TRIP POLES A B C POLES TRIP DESCRIPTION CKT ENCLOSURE:TYPE 1 MOUNTING:SURFACE WIRES:4 MAINS RATING:225 A FED FROM:BL1A-15 PHASE:3 MAINS TYPE:MLO LOCATION:CORRIDOR B00CA VOLTS:208Y/120V AIC RATING:22,000 PANEL LNP-B1 SCALE:NO SCALE2ONE-LINE DIAGRAM 1 9/12/19 ISSUE FOR DD REVIEW 2 10/31/19 ISSUE FOR PERMIT SCALE: NO SCALE 3 ACCESS CONTROL SCHEMATIC