HomeMy WebLinkAboutStamped Drawings for HF Johnson Museum of Art Curatorial OfficeHERBERT F. JOHNSON MUSEUM OF ART PRIVATE CURATORIAL OFFICE RENOVATIONS CORNELL UNIVERSITY ITHACA. NY PROJECT #: 34555 CONTRACT #: C13191 LOCATION MAP — BUILDING LOCATION KEY PLAN N SHADE I ND I GATES AREA OF WORK BUILDING PHOTO HERBERT F. JOHNSON MUSEUM OF ART z O 0 z W U � W lL > z O J J Q Q W Z O� < O U 0 W cc >> 0 ATE: 07-17-2013 V s_Umf CD 0 Cp 0 v w z DRAWING LIST A000 KEY PLAN AND CODE COMPLIANCE INFORMATION A001 GENERAL NOTES AND SPECIFICATIONS A002 SPECIFICATIONS A003 SPECIFICATIONS A100 PARTIAL DEMOLITION PLAN, PHOTOGRAPHS AND NOTES A101 PARTIAL RENOVATION PLAN, DETAILS AND NOTES M100 iMECHANICAL RENOVATION PLAN E000 ELECTRICAL NOTES E100 ELECTRICAL RENOVATION PLAN AND NOTES LOCATION MAP — BUILDING LOCATION KEY PLAN N SHADE I ND I GATES AREA OF WORK BUILDING PHOTO HERBERT F. JOHNSON MUSEUM OF ART z O 0 z W U � W lL > z O J J Q Q W Z O� < O U 0 W cc >> 0 ATE: 07-17-2013 V s_Umf CD 0 Cp 0 v w z OFF IGE 410 SF=102 ROL = 2 FOURTH LEVEL KEY PLAN TO SCALE SYMBOLS INDICATES HANDIGAP ACCESSIBILITY INDICATES WORK AREA - LEVEL 2 ALTERATIONS PER NEW YORK STATE EXISTING BUILDING CODE EW EGRESS WIDTH ROL ROOM OCCUPANT LOAD 0'7-17-2013 AS NOTED T5 U Q ea Drawing No. 0 0 0 CODE INFORMATION T 9 Q 9 4) N c 4) BGK-IBI Project No er m Ghent Project No. BUILDING SUMMARY: OGGUPANGY GLASSIFIGATION- MIXED USE CONSTRUCTION TYPE/ GLASSIFIGATION- IA EXISTING BUILDING AREA - NUMBER OF EXISTING STORIES- 6 WORK SUMMARY: EXISTING BUILDING CODE WORK AREA COMPLIANCE METHOD CLASSIFICATION OF WORK- ALTERATIONS LEVEL 2 (EB 404) OCCUPANCY GLASSIFIGATION- MIXED USE WORK AREA- 102 SF (0.03% OF FLOOR AREA) NUMBER OF TENANTS WITHIN WORK AREA- 1 (EB 105.1) FIRE SAFETY (GHAPTERS EB 6 AND EB 1): AUTOMATIC SPRINKLER SYSTEM- EXISTING IN GOMPLIANGE FIRE ALARM AND DETEGTION SYSTEM- EXISTING IN GOMPLIANGE IN I tRIOR FINISHES (EB 602 AND CHAPTER EB 1): EXIT AGGESS (GLASS A REQb PER )- GLA55 A PROVIDED. ROOM (GLASS A REQ'D PER )- GLASS A PROVIDED. EGRESS (OFFICE 410): OCCUPANT LOAD = 1025F /100 5F PER OCCUPANT = 2 DOOR WIDTH = 2X 0.15" = 03", 36" MIN., 36" PROVIDED REQUIRED NUMBER OF EXIT AGGE55 DOORWAYS : I, I PROVIDED Project Name: N Z I-0 00 11-1z I LT_ III Z Q Z O- 00Z U:<0 Wk) mI- _ } 0 Sheet Title z 0 w Q< o� c0 Z Z Z 111 <Z0 W � V 0 z GENERAL NOTES SPECIFICATIONS 1. ALL DIMENSIONS ARE TO BE FIELD VERIFIED PRIOR TO START OF CONSTRUCTION. 2. PATCH WALLS, FLOORS, ETC. AT REMOVAL AREAS TO MATCH SURROUNDING FINISHES. 3. PRIOR TO BEGINNING ANY WORK SECURE NECESSARY PERMITS AND/OR CLEARANCES FROM THE AUTHORITIES HAVING JURISDICTION. 4. SEE MECHANICAL, ELECTRICAL, AND SPRINKLER DRAWINGS FOR COORDINATION. 5. ALL DEMOLISHED MATERIAL TO BE REMOVED FROM SITE. CONTRACTOR TO RECYCLE APPROPRIATE MATERIAL AND DISPOSE OF REFUSE OFF SITE. G. ERECTION OF CONSTRUCTION BARRIERS PRIOR TO START OF WORK IS CRITICAL. NO WORK 13 TO COMMENCE WITHOUT OWNER APPROVAL OF CONSTRUCTION SEPARATION AND TEMPORARY BARRIER INCLUDING DUST AND PARTICULATE PROTECTION. SPECIFICATIONS 09 90 00 - PAINTS AND COATINGS PART 1 GENERAL 1.01 SECTION INCLUDES A.Fio|d application of paints. 1.02 SUBMITTALS A. Product Data: Provide data on all finishing products, including VOC content, block fillers, and primers. Provide manufacturers technical information, including label analysis, and instructions for handling, storing, and applying each coating. PART 2 PRODUCTS 2.01 MANUFACTURER A. Provide all paint and coating products used in any individual system from the same manufacturer. B. Paints: 1. Manufacturer: Benjamin Moore 2.02 GENERAL A. Paints and Coatings: Ready mixed, unless intended to be a field -catalyzed coating. All paints and coatings shall be of professional grade. 1. Material Compatibility: Provide, primers, undercoats, and finish -coat materials that are compatible with one another and the substrates indicated under conditions of service and application, as demonstrated by manufacturer based on testing and field experience. B. Primers: Where the manufacturer offers options on primers for a particular substrate, use primer categorized as "best" by the manufacturer. 09 90 00 - PAINTS AND COATINGS (cont.) PART 3 INSTALLATION 3.01 APPLICATION A. General: Apply paint according to manufacturer's written instructions. 3.02 PAINT SCHEDULE- INTERIOR 3.02 A. TYPE IP -2 Gypsum Wallboard: Semi -gloss, latex enamel finish. Two coats over a phmor, make and color as specified by owner to match existing paint system. 1. Primer: Latex board interior primer. Zero VOC, Iow odor, with anti -microbial agents. 2. First and second coats: Interior Latex Semi -gloss, zero VOC, low odor, with anti -microbial agents. 3.Color Vobo~whito^ Coordinate with owner on exacmanufacturer color number. B. TYPE IP -8 Wood Doors: Semi -Gloss Enamel Finish: Three coats with a water based primer and water based topcoat that is 100% acrylic, make and color as specified by owner to match existing paint system. 1. Primer Coat: Acrylic Primer. 2. First Coat: Acrylic Semi -Gloss. 3. Second Coat: Acrylic Semi -Gloss. 4.Color tobe\whito' Coordinate with owner on exact manufacturer color number. C. TYPE IP-lO HoIIow Metal Doors, Frames, and Sidelights, and Ferrous Metals: Semigloss, interior acrylic enamel finish 2 finish coaover primer. Primer is not required on shop -primed items. 1. Primer: Quick -drying, rust -inhibitive, alkyd -based or epoxy -metal primer. 2. First and Second Coats: Semi -gloss, exterior, acrylic enamel. 3. Color to be 'white'. Coordinate with owner on exact manufacturer color number. 08 11 13 - HOLLOW METAL DOOR FRAMES PART 1 GENERAL 1.01 SYSTEM DESCRIPTION A. Design Requirements: 1. Provide fabrication methods and product quality meeting standards set by Hollow Metal Manufacturers Association, HMMA, Division of National Association of Architectural Manufacturers, NAAMM. 1.02 SUBMITTALS A. Product Data: Submit manufacturer's specifications for fabrication and installation including data demonstrating compliance with specified requirements. B. Warranty 081113 HOLLOW METAL DOOR FRAMES (cont.) PART 2 PRODUCTS 2.01 MANUFACTURERS A. Manufacturers offering products complying with specified requirements include: 1. Steelcraft Manufacturing Co.. Cinoinnah, Ohio. 2.02 HOLLOW METAL COMPONENTS A. Requirements for All Frames: 1. Hardware Preparation: In accordance with BHMA A156.115, with reinforcement welded in place 2. Finish: Factory primod, for field finishing. 2.04 HOLLOW METAL FRAMES A. Materials: 1. Steel: Commercial quality, cold rolled steel conforming to ASTM A366 or hot -rolled, pickled and oiled steel conforming to ASTM A569, free of scale, pitting, coil breaks or other surface defects. a. Interior Openings:16 gage minimum thickness. B. Construction: All frames provided with integral stops and welded units, or knock down units, of sizes and types shown on Drawings. Provide frames with neat appearance, square, and free of defects, warps or buckies. 1. Stops: Minimum 5/8 in. depth: 2. Hardware Reinforcements and Preparation: a. Frames mortised, reinforced, drilled and tapped for all templated mortised hardware in accordance with final approved hardware schedule and templates provided by hardware supplier. 1) Where surface mounted, anchor hinges, or non-templated mortised hardware is to be app|ied, frames nainfnnmd, with all drilling and tapping in field. 3. Floor Anchors: Minimum 14 gage anchors with 2 holes for fasteners and fastened inside jambs with Ieast 4 spot welds per anchor. 4. Jamb Anchors: a. Metal Stud Type: provide 2 anchors min. 5. Frame Accessories: a. Plaster Guards: Not less than 26 gage stoo|, welded in place at all hardware mortises on frames set in masonry or concrete openings. 6. Finish: Frames treated to insure maximum paint adhesion and coated on all accessible surfaces with rust -inhibitive primer meeting or exceeding ASTM B117 salt spray for 150 hours and ASTM D1735 waterfog 7. Silencers: Resilient rubber, fitted into drilled hole; 3 on strike side of single door, 3 on center mullion of pairs, and 2 on head of pairs without center mullions. PART 3: INSTALLATION 3.01 INSTALLATION A. Comply with manufacturer's installation instructions and applicable recommendations in NAAMM/HMMA 840-99. 07-17-2013 AS NOTED 6-1 ^ 0 Drawing No.: m Designed by: 5G1< -1E31 Project No.: Glient Project No.: LU V 1 - LU Z it al co 1-11 Sheet Title: SPECIFICATIONS 08 14 16 - WOOD DOORS PART 1 GENERAL 1.01 REFERENCES A. AWI P-200 Architectural Woodwork Quality Standards Illustrated; Architectural Woodwork Institute. 1.02 SUBMITTALS A. Product Data: Indicate door core materials and construction; veneer species, type and characteristics. B. Warranty: PART 2 PRODUCTS 2.01 MANUFACTURERS A. Eggers Industries; Product Masterflush or equal. 2.02 WOOD DOOR PANEL A. Interior Doors: 1-3/4 inches thick; solid core construction . B. Veneer: Paint grade wood veneer, Oak species, unfinished for field painting. C. Panel partitions: Provide borrowed lite opening in top of door panel and louver opening in bottom of door panel, as indicated by elevation on drawing 2/A101. 2.03 FABRICATION A. Provide solid blocks at lock edge for hardware reinforcement. 1. Provide solid blocking for all other associated hardware. B. Bond edge banding to cores. C. Provide edge clearances in accordance with AWI 1600. PART 3 EXECUTION 3.01 EXAMINATION A. Verify existing conditions befre starting work. B. Verify that opening sizes and tolerances are acceptable. C.Do not install doors in frame openings that are not plumb or are out -of -tolerance for size or alignment. 3.02 INSTALLATION A. Install doors in accordance with manufacturer's instructions and AWI P'200 requirements. B. Trim non -rated door width by cutting equally on both jamb edges. C. Trim door height by cutting bottom edges to a maximum of 3/4 inch (19 mm). D. Machine cut for hardware. Core for handsets and cylinders. E. Pilot drill screw and bolt holes. DQ71UO'DOOR HARDWARE PART 1 - GENERAL 1.01 SUBMITTALS: Product Data- Submit manufacturers technical product data for each item of hardware. Include whatever information may be necessary to show compliance with requirements, and include instructions for installation and for maintenance of operating parts and finish. 1 .02- WARRANTY: - Locksets and associated components to have min. three year warranty. PART 2 PRODUCT 2.01 MANUFACTURERS AND PRODUCTS: A. Lockset- Sargeant 8205 B. ADA Lever Handle- Standard LNL. C. Hinges: Stanley FBB 179 4 1/2''x4 1/2" D. Cylinders: To be compatible with Cornell University lock cores. E. Silencers: Ives O871DO'DOOR HARDWARE (cont.) E. 2.02- SCHEDULE: Lockset (1) Each Door (Office Function) Lever (1) Each Side of Door Cylinder (1) Each Door Silencers (1 set) Each Door Hinges (3) Each Door F. ALUMINUM DOOR GRILL: Door return grilies shall be Titus Model CT -700 for the sizes and mounting types as shown on the plans and outlet schedule. Outer borders shall be constructed of heavy extruded aluminum with a thickness of 0.040 to 0.050- inch and shall have countersunk screw holes for a neat appearance. Border width shall be 1 V4 -inch on all sides and shall be interlocked at the four corners and mechanically staked to form a rigid frame. Extruded aluminum inverted V -blades with a deflection angle of 770 shall be used to create a sight proof design and provide additional stiffness to the grille. The grille finish shall be #26 white. The finish shall be an anodic acrylic paint, baked at 315° F for 30 minutes. The pencil hardness must be HB to H. The paint must pass a 1 00 -hour ASTM Bi 17 Corrosive Environments Salt Spray Test without creepage, blistering or deterioration of film. The paint must pass a 250 -hour ASTM D870 Water Immersion Test. The paint must also pass the ASTM D2794 Reverse Impact Cracking Test with a 50 -inch pound force applied. The manufacturer shall provide published performance data for the grille. The grille shall be tested in accordance with ANSI/ASHRAE Standard 70-2006. PART 3 INSTALLATION: Per manufacturer's instructions. OQ311G'GYPSUM BOARD ASSEMBLIES PART 1 GENERAL 1.01 SECTION INCLUDES A. Metal stud wall framing. B. Gypsum waliboard. 0. Acoustic Insulation. D. Sealant PART 2 PRODUCTS 2.01 GYPSUM BOARD ASSEMBLIES A. Provide completed assemblies complying with ASTM 0 840 and GA -216. 2.02 METAL FRAMING MATERIALS A. Manufacturers Metal Framing, Connectors, and Accessories: 1. Dietrich Metal Framing: www.dietrichindustries.com. B. Non-Loadbearing Framing System Components: ASTM 0 645; galvanized, 20 gauge sheet steel, of size and properties necessary to comply with ASTM C 754 for the spacing indicated, with maximum deflection of wall framing of L/240 at 5 psf. 1. Exception: The minimum metal thickness and section properties requirements of ASTM C 645 are waived provided steel of 40 ksi minimum yield strength is used, the metal is continuously dimpled, the effective thickness is at least twice the base metal thickness, and maximum stud heights are determined by testing in accordance with ASTM E 72 using assemblies specified by ASTM C 754. 2. Studs: '0' shaped with flat or formed webs with knurled faces. 3. Runners: U shaped, sized to match studs. 4. Ceiling Channels: 0 shaped. D. Partition Head To Structure Connections: Provide track fastened to structure with legs of sufficient length to accommodate deflection, for friction fit of studs cut short and braced with continuous bridging both sides. 2.03 GYPSUM BOARD MATERIALS A. Manufacturers: 1. USG: www.usg.com. US2118'GYPSUM BOARD ASSEK8BIES (uont.) B.Gypsum Wallboard: ASTM C1300K01306K4.Sizes tominimize joints inplace; ends square cut. 1. Wall Board: a. Application: Use for vertical surfaces and ceilings, unless otherwise indicated. b. Thickness: 5/8 inch. c. Edges: Tapered 0. Joint Materials: ASTM 0 475 and as recommended by gypsum board manufacturer for project conditions. 1. Tape: 2 inch wide, creased paper tape for joints and corners, except as otherwise indicated. 2. Ready -mixed vinyl -based joint compound. 3. Chemical hardening type compound. D. Screws: ASTM C 1002; self -piercing tapping type; cadmium -plated for exterior locations. E. Sealants: Provide paintable sealants compatible with finish systems. See manufacturer's requirements for more information. 2.04 ACOUSTIC INSULATION A. Manufacturer: Thermafiber B. Product: Sound Attentuation Fire Blanket 1. Nominal Density: 2.5 pcf 2.Sized for cavity in35/8^metal stud partition, 10^o.o. PART 3 INSTALLATION 3.01 FRAMING INSTALLATION A. Metal Framing: Install in accordance with ASTM 0 754 and manufacturer's instructions. B. Studs: Space studs at 16 inches on center. 1. Extend partition framing to structure supports or substrates above suspended ceilings, except where partitions are indicated to terminate at suspended ceilings. 2. Continue framing over frames for doors and openings and frame around ducts penetrating partitions above ceiling to provide support for gypsum board. a. Provide double track system comprised of outside deflection track and inside ceiling runner track at head of studs, nested together, with 1/2 clearance left between the tracks for deflection. Attach lower (inside) track to studs with framing screws. D. Openings: Reinforce openings as required for weight of doors, using two full height 20 gage studs at each jamb. 3.02 JOINT TREATMENT A. Paper Faced Gypsum Board: Use paperjoint tape, bedded with ready -mixed vinyl -based joint compound and finished with ready -mixed vinyl -based joint compound. B. Finish gypsum board in scheduled areas in accordance with Ievels defined in ASTM C84U. 0. Tape, fill, and sand exposed joints, edges, and corners to produce smooth surface ready to receive finishes, unless otherwise noted. 1. Feather coats ofjoint compound so that camber is maximum 1/32 inch. 2. Taping, filling and sanding is not required at base Iayer of double Iayer applications. 07-17-2013 AS NOTED TC3 ci ^ Drawing No.: m Designed by: E3G1<-1E31 Project No.: Glient Project No.: LU LLI Z it al co 1-11 Sheet Title: 0 ci m ca 0 08 14 16 - WOOD DOORS PART 1 GENERAL 1.01 REFERENCES A. AWI P-200 Architectural Woodwork Quality Standards Illustrated; Architectural Woodwork Institute. 1.02 SUBMITTALS A. Product Data: Indicate door core materials and construction; veneer species, type and characteristics. B. Warranty: PART 2 PRODUCTS 2.01 MANUFACTURERS A. Eggers Industries; Product Masterflush or equal. 2.02WOOD DOOR PANEL A. Interior Doors: 1-3/4 inches thick; solid core construction . B. Veneer: Paint grade wood veneer, Oak species, unfinished for field painting. 0. Panel partitions: Provide borrowed lite opening in top of door panel and louver opening in bottom of door panel, as indicated by elevation on drawing 2/A1O1. 2.03 FABRICATION A. Provide solid blocks at lock edge for hardware reinforcement. 1. Provide solid blocking for all other associated hardware. B. Bond edge banding to cores. C. Provide edge clearances in accordance with AWI 1600. PART 3 EXECUTION 3.01 EXAMINATION A. Verify existing conditions before starting work. B. Verify that opening sizes and tolerances are acceptable. C.Do not install doors in frame openings that are not plumb or are out -of -tolerance for size or alignment. 3.02 INSTALLATION A. Install doors in accordance with manufacturer's instructions and AWI P'200 requirements. B. Trim non -rated door width by cutting equally on both jamb edges. C. Trim door height by cutting bottom edges to a maximum of 3/4 inch (19 mm). D. Machine cut for hardware. Core for handsets and cylinders. E. Pilot drill screw and bolt holes. UD71OU'DOOR HARDWARE PART 1 - GENERAL 1.01- SUBMITTALS: Product Data- Submit manufacturers technical product data for each item of hardware. Include whatever information may be necessary to show compliance with requirements, and include instructioris for installation and for maintenance of operating parts and finish. 1 .02- WARRANTY: - Locksets and associated components to have min. three year warranty. PART 2 PRODUCT 2.01- MANUFACTURERS AND PRODUCTS: A. Lockset- Sargeant 8205 B. ADA Lever Handle- Standard LNL. C. Hinges: Stanley FBB 179 4 1/2''x4 1/2" D. Cylinders: To be compatible with Cornell University lock cores. E. Silencers: Ives SPECIFICATIONS 09 68 13 - CARPET TILE Part 1 General 1.01 SUBMITTALS: Product Data: Provide data on specified products, describing physical and performance characteristics; sizes, patterns, colors available, and method of installation. Samples: Submit one sample 3 x3 inch in size illustrating color and pattern for carpet and cushion material specified. Manufacturer's Installation Instructions: Indicate special procedures. Maintenance Data: lnclude maintenance procedures, recommended maintenance materials, and suggested schedule for cleaning. 1.02 PROJECT CONDITIONS Do not install carpet over concrete slabs until slabs have cured and are sufficiently dry to bond with adhesive and concrete slabs have pH range as foliows, unless otherwise recommended by carpet manufacturer. No condensation within 48 hours on underside of 4 -foot by 4 -foot polyethylene sheet, fully taped at perimeter to substrate. pH of 9 or Iess when substrate wetted with potable water and pHydrion paper applied. PART 2 PRODUCTS 2.01 MANUFACTURER Tandus Flooring, www.tandus.com 800-248-2878 2.02 Carpet Tile Product: Spun 03656 Manufactured by Tandus Tile size: 24"x 24" Backing: Flex -Aire Cushion RS Total Product Weight: 127.1 oz/yd Machine gauge: 1/12 Pile height: 0.187 Stitches per inch: 9.3 Flame resistance: Flooring Radiant Panel test (ASTM -E-648): Class 1 Surface Flammability: passes CPSC FF 1-70 Yarn content: Antron Legacy Dye Method: 65% solution, 35% yarn Color: Felt Noir 38201 Installation Method: Peel and stick tile (RS) 3.01 INSTALLATION Vacuum clean substrate. Install carpet tile in accordance with manufacturer's instructions and CRI Carpet Installation Standard. Blend carpet from different cartons to ensure minimal variation in color match. Cut carpet tile clean. Fit carpet tight to intersection with vertical surfaces without gaps. Lay carpet tile in square pattern, with pile direction parallel to next unit, set parailel to building lines. Locate change of color or pattern between rooms under door centerline. Trim carpet tile neatly at walis and around interruptions. Complete installation of edge strips, concealing exposed edges. Provide vinyl transition and reducer strips as required. Clean and vacuum carpet surfaces. 07-17-2013 A5 NOTED Drawing No.: Lu Designed by: E3C,K-151 Project No.: en u Sheet Title: LT 0 ©> 0 z 410 D2 se) L_ D3 (ABOVE) DI 8'-O I/2"± Y.I.F. DEMOLITION NOTES DI REMOVE EXISTING CARPET IN ITS ENTIRETY, INCLUDING PAD AND/OR ADHESIVE, DOWN TO CONCRETE SUB FLOWER. PREPARE CONCRETE TO RECEIVE NEW CARPET TILE SYSTEM INCLUDING PATCHING OF EXISTING CONCRETE FLOOR. 02 EXISTING CARPET TO REMAIN. D3 REMOVE PORTION OF EXISTING PLASTER CEILING TO ACCOMMODATE INSTALLATION OF NEW EXHAUST FAN. SEE MECHANICAL DRAWING FOR MORE INFORMATION. D4 EXISTING ELECTRICAL DEVICES INCLUDING FIXTURE, HEAT DETECTOR, ETG. TO REMAIN. 05 HATCH INDICATES FACE OF NEW WALL CONSTRUCTION. 1:76 EXISTING PLASTER CEILING TO REMAIN. DI PREPARE WALL FOR INSTALLATION OF SURFACE MOUNTED ELECTRICAL RACEWAY. SEE ELECTRICAL DRAWINGS FOR MORE INFORMATION. FOURTH LEVEL PARTIAL DEMOLITION PLAN I/4«al'-O• PHOTOS TS. 7 176 - 171 07-17-2013 AS NOTED 0 0 Q Drawing No. 0 0 4: CD N c CSS N Q BGK-IBI Project No m Ghent Project No. a- m 0 z I. 0 O 0 LU — �0V • 111 ZO2 O,[J O 0z • <o MVV V mI- _ } V I - z ,c o_ Sheet Title 0 O z 0 0= 0 W .< <0 F a0_ z ca .001 Al Al OFFICE 410 100 SF A4 8'-0 1/2"t BOX HEADER, GONTINUOUS OVER DOOR AND LITE OPENING SEALANT, ALL EDGES OF FRAME, BOTH SIDES OF PARTITION AREA 404i k" CLEAR SAFETY GLASS HOLLOW METAL FRAME, PAINT EXISTING CARPET TO REMAIN J ,L V.I.F. A2 OFFICE 410 EXISTING PLASTER CEILING. PATGH, REPAIR AND PAINT CEILING IF DAMAGED DURING GONSTRUGTION SEALANT, BOTH SIDES NEW PARTITION, SEE NOTE Al NEW GARPET ON EXISTING CONCRETE FLOOR INTERIOR ELEVATION I/4'=I'-0' DOUBLE STUD WALL AT END WALL GONDITION NEW PARTITION, SEE NOTE Al FOURTH LEVEL PARTIAL RENOVATION PLAN INTERIOR ELEVATION RENOVATION NOTES Al A2 A3 A4 A5 A6 Ai AS PROVIDE 3g" METAL 5TUD PARTITION, 20 ga. 16" ON GENTER WITH g" GYPSUM WALL BOARD EACH SIDE WITH THERMAL FIBER BLANKET IN CAVITY, PAINT. PROVIDE i" GLEAR SAFETY GLASS FOR ALL BORROWED LITES. PROVIDE NEW 3'X1' SOLID CORE W900 DOOR PANEL, I-" WITH HALF GLASS LITE AND TRANSFER GRILLE PANEL. PROVIDE ALL DOOR HARDWARE A5 REQUIRED FOR A COMPLETE INSTALLATION. PROVIDE NEW GARPET TILE FLOORING THROUGHOUT SPACE. PROVIDE NEW VINYL BASE AT ENTIRE h±KIMETER OF NEW GARPET. IN ADDITION TO NEW PARTITION GONSTRUGTION, PREPARE AND PAINT EXISTING WALL IN SPAGE AS INDICATED. APPROXIMATE LOGATION OF NEW EXHAUST FAN, 5CE MEGHANIGAL DRAWINGS FOR MORE INFORMATION. PROVIDE NEW HOLLOW METAL FRAME FOR DOOR AND BORROWED LITE OPENINGS WITH METAL STUD ANCHORS, 16 ga, WITH SEALANT AT ALL EDGES, PAINT. 24" X 24" ALUMINUM GRILLE, SEE SPEGIFIGATIONS AND MEGHANIGAL DRAWING. 07-17-2013 CD A5 NOTED cis 0 Drawing No. w v Q m w V v BGK-IBI Project No PLAN DETAIL I/2'=I'-0' SEALANT EXISTING METAL STUD WALL EXISTING GONGRETE EXTERIOR WALL EXISTING INTERIOR GONGRETE WALL DOUBLE STUD AT DOOR JAMB, BOTH SIDES NEW HOLLOW METAL FRAME, PAINT NEW DOOR i DOOR JAMB I/2'=I'-0' NEW PART TION, SEE NOTE Al SEALANT N I- 0 < 4C O Q LU — � • k) Z Q z Q � Z< O 0Z V0 V rn 1-11 fY I— LIA% ° I_ ,c a_ z o_ Z I- 0 0 } z 0 W <w IY 0_ Sheet Title N L w }• Q N o o z z' o ff L ac' pc; NN C7 CD - • w 0co Y Y U gm2$9 U 0'- > - z ca 360 CFM, TITUS CT -700 22x20 NECK, 24x22 MODULE EXG. 24x24 CEILING ACCESS DOOR FAN F-1, GREENHECK CSP -A390, 360 CFM, 0.3"WG TSP INSTALL F-1 IN CEILING, DISCHARGE TO CEILING PLENUM OFFICE 410 12"x10" DUCT WITH 1" ACOUSTIC LINING 360 CFM, TITUS 50F-1", 10"x12", WHITE FINISH FOURTH LEVEL PARTIAL PARTIAL RENOVATION PLAN IDN NOTES: 1. EXISTING EQUIPMENT IS ADEQUATE TO PROVIDE VENTILATION REQUIRED TO SATISFY CODE. 2. FAN WILL OPERATE BY OCCUPANCY SENSOR LOCATED IN CEILING. SEE E100. 07-17-2013 Oil 4) AS NOTED 4) 0 Q Drawing No. 0 0 3 4) c k 4) Q BCK-IBI Project No z° � m v 0 IL v Sheet Title MECHANICAL RENOVATION PLAN > m z ca GENERAL DEMOLITION NOTES A. THIS INFORMATION REPRESENTS EXISTING GONDITIONS BASED ON ORIGINAL DRAWINGS AND OBSERVED SITE CONDITIONS. NOT ALL CONDUIT, WIRE, AND DEVICES ARE SHOWN. THE CONTRACTOR SHALL FIELD VERIFY CIRCUITING, ROUTING, AND EXACT QUANTITIES SHOWN. THE CONTRACTOR SHALL DISCONNECT, REMOVE, AND DISPOSE OF ALL EXISTING CONDUIT, WIRE, SURFAGE RACEWAY, FIXTURES, AND DEVICES THAT ARE NOT SCHEDULE FOR RBJSE. PROVIDE FIRESTOP, GUTTING, AND PATGHIN6 AS REQUIRE TO REPAIR HOLES, UNPAINTED AREAS, OR OTHER PHYSICAL DEFECTS CAUSED BY THE REMOVAL/INSTALLATION OF EQUIPMENT AND DEVICES. THE CONTRACTOR SHALL PROVIDE A QUALIFIED TRADES PERSON OR CONTRACTOR TO RESTORE FINISHED WALLS TO ORIGINAL CONDITION AND PAINT TO MATCH EXISTING WALL DOLOR G. WHERE EXISTING DEVICES ARE BEING REMOVED AND THE REMOVAL BREAKS AN EXISTING BRANCH CIRCUIT TO A DOWNSTREAM DEVICE, THE CONTRACTOR SHALL PROVIDE ALL CIRCUITING REQUIRED TO PREEMINENTLY REGONNEGT THE REMAINING DEVICE, EQUIPMENT, OR FIXTURE. REMOVE ALL ABANDONED WIRING AND RACEWAY. D. COORDINATE ALL REQUIRED SHUTDOWNS WITH THE OWNER A MINIMUM OF (2) WEEKS IN ADVANCE. SHUTDOWNS THAT WILL INTERRUPT NORMAL ACTIVITY MUST BE DONE AFTER HOURS OR ON HEEKENDS. E. LEGALLY DISPOSE OF ALL ELEGTRIGAL WIRING, DEVICES, BALLAST, LAMPS, ETC. IT SHOULD BE ASSUMED THAT THERE 15 EXISTING PGB CONTAINING BALLASTS AND MERCURY CONTAINING LAMPS. FOLLOW ALL LOGAL, STATE, AND FEDERAL REGULATIONS REGARDING DISPOSAL OF HAZARDOUS WASTE F. MAKE ALL CONNECTIONS NECESSARY TO MAINTAIN EXISTING SYSTEMS WHERE PARTIAL DEMOLITION IS REQUIRED DUE TO SCHEDULING. B. 6, WHERE EXISTING BRANCH CIRCUITING 15 TO REMAIN FOR REUSE. THE ELECTRICAL CONTRACTOR SHALL RESUPPORT, MODIFY, OR REPAIR AS NEEDED TO ENSURE COMPLIANCE WITH ALL NEG AND SPECIFICATION REQUIREMENTS. GENERAL INSTALLATION NOTES A. PROVIDE (2)#10, (0IOE6 WIRING FOR 120V, 20A BRANCH CIRCUITS EXCEEDING IOOFT. B. PROVIDE UPDATED TYPE WRITTEN PANELBOARD SCHEDULE -5 FOR ALL PANELS USED IN RENOVATION. G. COORDINATE DEVICE LOCATIONS WITH ARCHITECTURAL ELEVATIONS PRIOR TO ROUGH -IN. VERIFY DEVICE LOCATIONS ABOVE MILL WORK TO ENSURE CLEARANCE ABOVE THE COUNTER -TOP AND BACK SPLASH. DEVICES THAT INTERFERE WITH NEW CASEWORK, MILLWORK, OR EQUIPMENT SHALL BE RELOCATED AT NO ADDITIONAL DOST TO THE CONTRACT. D. COORDINATE ALL CONDUIT RUNS WITH OTHER TRADES PRIOR TO ROUGH -IN. RELOCATE ANY CONDUITS AS NECESSARY TO PERMIT INSTALLATION OF DUCTWORK OR PIPING. E. INSTALL ALL CIRCUITING CONGEALED INSIDE WALL CAVITY WHEREVER POSSIBLE. PROVIDE SURFACE MOUNTED BAGKBOXES AND RACEWAY FOR WIRING DEVIGES LOCATED ON EXISTING SOLID WALL CONSTRUCTION. PROVIDE SHALLOW TYPE BACKBOXES FOR SURFACE MOUNTED POWER AND SWITCHING APPLICATIONS. REFER TO ARCHITECTURAL PLANS FOR WALL TYPES. F. FIRESTOP ALL LOW VOLTAGE SLEEVE -5 AND PENETRATIONS AFTER INSTALLATION OF GABLE. 6. ALL LOH VOLTAGE CABLING SHALL BE PLENUM RATED. H. EXISTING JUNCTION BOXES AND CONDUITS MAY BE REUSED IF PRAGIICAL AND MEETING THE DESIGN INTENT. WiERE EXISTING BOXES AND CONDUITS ARE REUSED, THE ELECTRICAL GONTRAGTOR SHALL RESU'PORT, MODIFY, OR REPAIR A5 NEEDED TO ENSURE COMPLIANCE WITH ALL NEG AND SPECIFICATION REQUIREMENTS. I. THE DRAWINGS 5HOW GENERAL LOCATIONS OF DEVICES AND EQUIPMENT. THE CONTRACTOR SHALL INSTALL ALL DEVICES TO MEET ALL NEG REQUIREMENTS. COORDINATE THE EXACT LOCATION IN THE FIELD. OBTAIN WIRING AND INSTALLATION DIAGRAMS FOR ALL ELECTRICAL CONNECTIONS TO EQUIPMENT PROVIDED BY THE GENERAL, MECHANICAL, OR PLUMBING CONTRACTORS PRIOR TO ROUGH -IN. WORK THAT 15 NOT PROPERLY COORDINATED WILL BE RELOCATED AT NO DOST TO THE OWNER K. THE CONTRACTOR SHALL FIELD VERIFY EXACT ROUTING OF ALL SURFACE RACEWAY IN FIELD. L. THE CONTRACTOR SHALL COORDINATE ALL ELECTRICAL CONNECTIONS TO ELECTRICAL EQUIPMENT PROVIDED BY OTHERS PRIOR TO ROUGH -IN. M. PROVIDE - FURNISH ALL MATERIALS, LABOR, AND SERVICES TO COMPLETE THE WORK INDICATED. N. INSTALL - PROVIDE LABOR AND MISCELLANEOUS MATERIALS TO MAKE A PRIMARY PIE -GE OF EQUIPMENT FURNISHED BY ANOTHER CONTRACTOR READY FOR USE 0. FURNISH - DELIVER EQUIPMENT TO THE SITE TO BE INSTALLED BY ANOTHER CONTRACTOR P. ALL HIRING SHALL BE THHN GU, ALL CONDUIT EMT OR FMG. Q, PAINT ALL SURFACE MOUNTED BOXES AND EXPOSED CONDUIT TO MATCH BACKGROUND. R. ALL WORK SHALL CONFORM TO NEC 2011, STATE AND LOCAL GODES. J. GENERAL POWER DISTRIBUTION NOTES A. THE EXACT BREAKER CONFIGURATION FOR PANELBOARDS SHALL BE VERIFIED AFTER FIELD INVESTIGATION. IT 15 LIKELY THAT MINOR CHANGES WILL BE REQUIRED. 11 [SC CHANGES SHALL BE MADE AT NO ADDITIONAL COST TO THE OWNER PRIOR TO RELEASING THE PANELBOARD ORDER IF PHASING REQUIRES THE RELEASE OF THE ORDER PRIOR TO FIELD CONFIRMATION BREAKER CHANGES WILL BE MADE IN TFIE FIELD AT NO ADDITIONAL COST. PROVIDE AS BUILT DRAWINGS OF THE PANELBOARD SCHEDULES INDICATING THE SIZE AND LOAD ON ALL BRANCH CIRCUITS AS INSTALLED. B. THE DRAWINGS SHOW APPROXIMATE LOCATION OF FANS. THE EXACT LOCATION OF THE FANS SHALL BE DETERMINED IN THE FIELD AND INSTAI 1 FD PER NEC REQUIREMENTS. G. NEW BREAKERS INSTALLED INTO EXISTING PANELBOARDS SHALL MATCH THE KAIG RATING OF THE EXISTING PANELBOARD AND SHALL BE LISTED AND LABELED FOR USE WITH EXISTING PANELBOARD. FIRE ALARM NOTES A. PROVIDE INDEPENDENT GABLE SUPPORTS FOR FIRE ALARM GABLE AND USE GABLE TRAY WHERE EXISTING. ALARM GABLE SHALL BE RUN ABOVE CEILING AND BE INDEPENDENT OF ALL OTHER WIRING. USE PLENUM RATED GABLIN6 IN ALL AIR PLENUM LOCATIONS. B. TEST AND RECERTIFY FIRE ALARM INSTALLATION IN RENOVATED AREA. G. THE EXISTING BUILDING FIRE ALARM SYSTEM SHALL BE MAINTAINED AT ALL TIMES. D. ADDITIONAL COMPONENTS MUST BE INSTALLED AND GONNEGTED TO FIRE ALARM SYSTEM BY MANUFACTURER'S REPRESENTATIVE AND STATE LICENSED CONTRACTOR 07-17-2013 0 z T5 v Drawing No.: 0 0 '0 W 1a J N J v I -Z O 0 ‘)ILIV • LL > O 0n _ , W O 0ty • 0 • v LLI Lu IIn I- LUea E o_ BGK-IBI Project No Sheet Title: L L L m ELECTRICAL NOTES Ghent Project No.: m z EXISTING GAN LIGHT IYP. (12) FOURTH FLOOR RENOVATION PARTIAL PLAN 1/4"=1'-0" RENOVATION KEYED NOTES PROVIDE NEW HEAT DETECTOR, SAME MAKE AND MODEL AS EXISTING. REFER TO FIRE ALARM NOTES ON SHEET E000. TAP EXISTING 120V BRANCH GIRGUIT AT EXISTING DUPLEX WITH (3) #12. EXTEND CIRCUIT ON BASEBOARD IN WIREMOLD 100 RAGEWAY TO NEW PARTITION. WIREMOLD SHALL BE BLACK TO MATGH EXISTING BASEBOARD. TRADE GIRGUIT PRIOR TO THIS WORK AND VERIFY LOAD 15 LESS THAN 1OA. EXTEND WIRING, IN NOTE 2 IN WALL AND PROVIDE NEW DOUBLE 5-I5R DUPLEX AT IS" A.F.F. PROVIDE 20A WATTSTOPPER POWER PACK BTI20 ABOVE GEILIN6 AND EXTEND SAME BRANCH GIRGUIT IN NOTE 3 THROUGH POWER PAGK TO POWER FAN F -I (BY OTHERS). PROVIDE WATTSTOPPER DT -300 OCCUPANCY SENSOR ON GEILIN6 TO CONTROL ON-OFF FAN. ELECTRICAL LEGEND 0 6 F -I - EXISTING GAN LIGHT (CEILINS MOUNT) - OCCUPANCY SENSOR (CEILING MOUNTED) - EXISTING DUPLEX RECEPTACLE - DOUBLE DUPLEX RECEPTACLE 5-I5R - RATE OF RISE HEAT DETECTOR - WIREMOLD 100 - FAN MOTOR 07-17-2013 AS NOTED 3 a Drawing No. 0 0 3 RS 0 a _ BCK-IBI Project No 0 z 0 els .Q a U N O 0 ni • } 00D _4� 0 • fr LI- ri Lu CO I— V 2 ez CR CR 0- ra N 1- 0 Q 4C 0 z 0 } 0 W fY W J W w z ca