Loading...
HomeMy WebLinkAboutSibley HallN PROJECT SCOPE Ithaca, New York Cornell University DRAWING LIST ELECTRICAL T-001 TITLE SHEET AE-000 AREA OF WORK Facilities Engineering Engineering Electrical, Environmental & Energy Civil, Structural, Architectural, Mechanical, Humphreys Service Building; Ithaca, N.Y. G-001 ARCHITECTURAL T-001 TITLE SHEET FE DESIGN jd N AREA OF WORK SITE PLAN - SIBLEY HALL LOCATION PLAN - SIBLEY HALL, ROOM 260 A-102 E-102 Room 260 Renovations Sibley Hall CODE REVIEW SUMMARY SCOPE OF WORK, PATTERNS, SYMBOLS, DETAILS AND SCHEDULES ROOM 260 DEMOLITION, FURNITURE LAYOUT, CONSTRUCTION, AND INTERIOR ELEVATION ROOM 260 DEMOLITION AND NEW WORK offices and reconfiguring workspaces within room 260. of the enclosed fire stair (200SD) as well as erecting partitions for private replacing the existing entrance through 200CE with a new door outside of non load-bearing partitions as required by the project, removing and deficiencies in the adjacent stairwell (200SD). This work includes demolition in Sibley Hall to better meet current needs. It will also remove some code The purpose of this project is to alter office space in rooms 260 and 260A WARNING: IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT HIS SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. CIVIL: ELEC: MECH: ARCH: REVISIONS: DATE: FACILITY: DESIGN: DRAWN: 15 A B C D E F G H I A B C D E F G H 16 14 13 12 11 10 9 8 7 6 5 4 3 2 1 1516 14 13 12 11 10 9 8 7 6 5 4 3 2 1 ARCHIVE BAR CODEIthaca, New YorkCORNELLUNIVERSITY FO UN DED5681ADFacilities EngineeringCornell University2004 Sibley Hall8264312Room 260 RenovationsSibley Hall DATE: 10/16/15 - ISSUED FOR CONSTRUCTION October 16, 2015 CENTRAL AVENUE2007 OLIVE TJADEN HALL 2002 WHITE HALL UNIVERSITY AVENUE 2004 SIBLEY HALL 2008 LINCOLN HALL 2015 FOUNDRY 2017 RAND HALL EAST AVENUE5310 PLANT HYDROELECTRIC 2015A FOUNDRY KILN SHED 3802 PAUL MILSTEIN HALL CB CB UP 2008 EAST HALL LINCOLN UNIVERSITY AVENUE 2004 SIBLEY HALL 2015 FOUNDRY 3802 PAUL MILSTEIN HALL UP 2008 EAST HALL LINCOLN WARNING: IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT HIS SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. CIVIL: ELEC: MECH: ARCH: REVISIONS: DATE: FACILITY: DESIGN: DRAWN: 15 A B C D E F G H I A B C D E F G H 16 14 13 12 11 10 9 8 7 6 5 4 3 2 1 1516 14 13 12 11 10 9 8 7 6 5 4 3 2 1 ARCHIVE BAR CODEIthaca, New YorkCORNELLUNIVERSITY FO UN DED5681ADFacilities EngineeringCornell University2004 Sibley Hall8264312Room 260 RenovationsSibley Hall DATE: 10/16/15 - ISSUED FOR CONSTRUCTION October 16, 2015 UP UP UP UP UPDN200SE 200SB 235A 200SC 200TB 200SDDN DN 252240B 240 240C 240D 240E 240F 240G 261A 261B 261 UP 200TC 200JB 200EB 200CD 200EA 240H 253 200UA 235B 235C 235D 235E 235F 235G 235H 235 200SF 235J 250 260A 260 200CE N 1 SCALE: 2 G-001 SUMMARY CODE REVIEW CODE SUMMARY REVIEW C. HOOVER TEMPORARY EGRESS PATH FOR THE DURATION OF CONSTRUCTION 0 8 16 32 SCALE: 1/16"=1'-0" 1/16" = 1'-0" AREA OF WORK cfh DURING CONSTRUCTION AS AFFECTED BY THIS WORK. 5. CONTRACTOR RESPONSIBLE FOR ALL CODE COMPLIANT SIGNAGE AND EXITING ENSURE THEY DO NOT IMPEDE DAILY ACTIVITIES OR EGRESS. 4. COORDINATE WITH OWNER FOR LOCATIONS OF ALTERNATE EXITING SIGNAGE TO TO BE DISPLAYED FOR THE DURATION OF CONSTRUCTION. 3. COORDINATE WITH AHJ AND EH&S FOR ALTERNATE EXITING SIGNAGE OPENING ON STAIRWELL LANDING. KEEP LANDING CLEAR FOR EGRESS. EXISTING DOOR AS WELL AS CONSTRUCTION OF CMU INFILL OF 2. ERECT AND MAINTAIN A PLASTIC DUST BARRIER DURING REMOVAL OF ONE WEEK MAXIMUM) OPENING (LIMIT CONSTRUCTION ON STAIRWELL TO D) DEMOLISH EXISTING ENTRANCE DOOR; BLOCK IN C) INSTALL NEW ENTRANCE DOOR B) REMOVE AND DISPOSE OF ALL MATERIALS A) DEMO PARTITIONS AND REMOVE PLYWOOD FLOOR AND CONSTRUCTION SHALL SEQUENCE AS FOLLOWS: 1. PER BUILDING PERMIT REQUIREMENTS, DEMOLITION NOTES: AE-000 SCOPE OF WORK ARCHITECTURAL SCOPE OF WORK: ARCHITECTURAL GENERAL NOTES: SYMBOLS 1.0 22 N 99 XX XXXXX F1 999 D16 A103 INTERIOR ELEVATION NORTH ARROW ROOM DATA SECTION KEYNOTE - NEW WORK KEYNOTE - DEMOLITION ITEM FOR DEMOLITION BREAK LINE DOOR - EXISTING TO REMAIN NOTES ABBREVIATIONS WALL - EXISTING TO REMAIN WALL - NEW GWB & STUD WALL - EXISTING TO BE REMOVED ARCHITECTURAL PATTERNS E3 TAG - CASEWORKC TAG - EQUIPMENT TAG - FINISH ELEVATION MARKER B.O. BOTTOM OF BYND BEYOND CLG CEILING DTL DETAIL GWB GYPSUM WALL BOARD MTL METAL O.C.ON CENTER PTD PAINTED RCP REFLECTED CEILING PLAN SIM SIMILAR T.O.TOP OF TYP TYPICAL U.N.O.UNLESS NOTED OTHERWISE U/S UNDERSIDE V.I.F.VERIFY IN FIELD THK THICK 011 7 TAG - FURNISHING TAG - DOOR DOOR & FRAME TYPES4 SCALE: NONE FRAME DETAILS5 SCALE: NONE BATT INSULATION P1 2 C. HOOVER AND SCHEDULES SYMBOLS, DETAILS WORK, PATTERNS, SCOPE OF 1SCALE: NONE WALL TYPE BACKER ROD AND SEALANT BACKER ROD AND SEALANT CONNECTING BRACE4 1/2"6 DOOR AND HARDWARE SCHEDULES ARCHITECTURAL SUBMITTAL SCHEDULE3 BATT INSULATION 6" MTL STUD 5/8" TYPE GWB BOTH SIDES PARTITION (NO RATING REQUIRED) 6" MTL STUD 5/8" TYPE GWB 5/8" TYPE GWB 1/4" SAFETY GLASS ANODIZED ALUMINUM STOREFRONT SYSTEM BASIS OF DESIGN "TUBELITE 4500" CLEAR, 6"6"7 1/4 " 6" A-000 7'-0"3'-0"7'-2"3'-3 1/2 " 1 3/4 "1 3/4 "1 3/4 "D-1 F-1 7'-0"3'-0"2 1/8 "10"2 1/8 "2 1/8 " D-2 STOREFRONT DOOR (N.I.C.) 1 3/4 "3'-0" F-2 STOREFRONT UNIT (N.I.C.) 1 3/4 "1 3/4 "1 3/4 "1 3/4 "6'-0"8'-0"7'-0"D: F-2 HEADER/TRANSOM DETAIL C: F-2 JAMB DETAILS B: F-1 HEAD DETAIL A: F-1 JAMB DETAIL 2-D 2-C A-000 A-000 2-D 2-C A-000 OFFICES AND RECONFIGURING WORKSPACES WITHIN ROOM 260. FIRE STAIR (200SD) AS WELL AS ERECTING PARTITIONS FOR PRIVATE ENTRANCE THROUGH 200CE WITH A NEW DOOR OUTSIDE OF THE ENCLOSED REQUIRED BY THE PROJECT, REMOVING AND REPLACING THE EXISTING THE SCOPE INCLUDES DEMOLITION OF NON LOAD-BEARING PARTITIONS AS SCALE: NONE CASEWORK DETAILS1'-6"1'-6"2'-0"1'-6"RAKK PART NUMBER EH-1818 RAKK PART NUMBER EH-1824 ELECTRICAL SYMBOLOGY EXISTING TO BE REMOVED EXISTING TO REMAIN NEW ch/jd 24" COUNTERTOP 30" COUNTERTOP PRIOR TO SIZING NEW JAMB VERIFY EXISTING PARTITION WIDTH BACKER ROD AND SEALANT 10"5"5"5"PROVIDE SHOP DRAWINGS AND INDICATE AND DETAIL ANY REQ’D BRACING. NOTE: REPAIRED AT NO COST TO THE OWNER. NOT LIMITED TO THE LOBBY AND CORRIDOR SHALL BE DAMAGE TO AREAS OUTSIDE THE PROJECT AREA INCLUDING BUT TO BRING SUPPLIES AND EQUIPMENT INTO THE PROJECT AREA. ANY CONTRACTOR IS RESPONSIBLE FOR PROTECTING ALL AREAS USED10.0 PROGRESSED TO A POINT THAT A CONTAINER IS NO LONGER REQUIRED. WILL BE REMOVED AS SOON AS FULL OR WHEN THE PROJECT HAS OR TO VEHICLE WHICH WILL REMOVE DEBRIS FROM CAMPUS. CONTAINERS JOBSITE WILL BE CLEANED DAILY AND DEBRIS REMOVED TO CONTAINERS9.0 MATERIAL AND THE FILL, VOID OR CAVITY MATERIAL. EXPANSION JOINTS. FIRE STOPPING INCLUDES BOTH FORM OR PACKING WALL TO FLOOR OR ROOF DECK, WALL TO BEAMS, AND CONTROL OR STOPPED. GAPS AND JOINTS INCLUDE (BUT ARE NOT LIMITED TO) TOP OF AND JOINTS AT RATED FLOORS, ROOFS AND WALLS TO BE FIRE & SMOKE HEIGHT WALLS - IN AREA OF WORK TO BE FIRE STOPPED. ALL GAPS ALL PENETRATIONS (EXISTING OR NEW )THROUGH FLOORS AND FULL8.0 OF ALL ITEMS. ITEMS, VERIFY AND CONFIRM WITH EACH CONTRACTOR EXACT LOCATION AND WELL COORDINATED INSTALLATION. PRIOR TO INSTALLATION OF DIMENSIONS AND ALL OTHER INFORMATION NECESSARY FOR A PROPER INFORMATION SUCH AS SIZES, LOCATIONS, TEMPLATES, LAYOUT, PREVENT CONFLICTS AND INTERFERENCES. OBTAIN ALL NECESSARY SCHEDULE WORK PROGRESS THROUGHOUT THE ENTIRE PROJECT TO GENERAL CONTRACTOR IS TO COORDINATE WORK OF ALL TRADES. 7.0 AREAS TO ORIGINAL CONDITION. AS NECESSARY TO PERFORM WORK AND RESTORE THESE SPACES OR OF CEILINGS, WALLS, FINISHES, PAVEMENT AND OTHER CONSTRUCTION REQUIRED IN THESE AREAS CONSISTING OF REMOVAL / REPLACEMENT ALTHOUGH NOT NECESSARILY SHOWN ON DRAWINGS, WORK IS EXECUTE WORK OF OTHER TRADES (i.e. ELECTRICAL, MECHANICAL). WORK IS REQUIRED IN VARIOUS PORTIONS OF THE FACILITY TO6.0 ROOF OR FLOOR TO BE INFILLED SOLID. ABANDONED OPENINGS (i.e. DUCT/PIPE REMOVALS, ETC.) AT WALLS, RECONSTRUCTED WITH MATERIALS TO MATCH FINISHED AREAS. ALL RESULTING SURFACES AND INFILLED SURFACES SHALL BE CAUSING THE EXPOSURE OF UNFINISHED AND/OR DAMAGED SURFACES REMOVED AND / OR DISTURBED FOR INSTALLATION OF NEW WORK, WHERE EXISTING CONSTRUCTION OR ITEMS HAVE BEEN INFILLED,5.0 CLARIFICATION IN WRITING. CLARIFICATION FROM THE ARCHITECT/ENGINEER AND PROVIDE CONDITIONS, NOTIFY THE PROJECT MANAGER, WHO WILL REQUEST THERE ARE ANY DISCREPANCIES BETWEEN DRAWINGS AND FIELD CONDITIONS PRIOR T0 SUBMITTING BIDS AND COMMENCING WORK. IF CONTRACTOR IS RESPONSIBLE TO VERIFY ALL SITE, FIELD AND BUILDING4.0 SHALL BE REPLACED AT NO COST TO THE OWNER. OR WHERE THE STRUCTURAL INTEGRITY HAS BEEN AFFECTED, ITEMS OWNER. WHERE ITEMS CAN NOT BE REPAIRED TO A "NEW CONDITION", DAMAGED SHALL BE REPAIRED OR REPLACED AT NO COST TO THE NEW, UNLESS INDICATED EXISTING. ALL WORK WHICH HAS BEEN TO OWNER'S APPROVAL. ALL ITEMS AND WORK ON DRAWINGS ARE TO MATCH EXISTING, PROVIDE CLOSEST POSSIBLE MATCH, SUBJECT PROVIDE BEST QUALITY MATERIALS. WHERE MATERIALS ARE INTENDED COMPLETE THE WORK OF THIS CONTRACT ARE NOT SPECIFIED HEREIN, WHERE MATERIALS REFERENCED ON DRAWINGS, OR NECESSARY TO3.0 AND / OR NOTES. SPECIFICALLY INDICATED ON ANY OTHER PORTION OF THE DRAWINGS REGARDLESS OF WHETHER OR NOT ALL WORK OR EACH ITEM IS INCLUDE ALL MATERIALS AND LABOR NECESSARY TO COMPLETE, OF THE AREAS INDICATED BY THE CONTRACT DOCUMENTS, AND SHALL THIS CONTRACT REQUIRES COMPLETE, FINISHED WORKABLE PROJECT2.0 YORK STATE BUILDING CODE AND THE CITY OF ITHACA AMENDMENTS. CODE: THE STRUCTURE IS DESIGNED IN ACCORDANCE WITH THE NEW 1.0 WARNING: IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT HIS SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. CIVIL: ELEC: MECH: ARCH: REVISIONS: DATE: FACILITY: DESIGN: DRAWN: 15 A B C D E F G H I A B C D E F G H 16 14 13 12 11 10 9 8 7 6 5 4 3 2 1 1516 14 13 12 11 10 9 8 7 6 5 4 3 2 1 ARCHIVE BAR CODEIthaca, New YorkCORNELLUNIVERSITY FO UN DED5681ADFacilities EngineeringCornell University2004 Sibley Hall8264312Room 260 RenovationsSibley Hall DATE: 10/16/15 - ISSUED FOR CONSTRUCTION October 16, 2015 WARNING: IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT HIS SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. CIVIL: ELEC: MECH: ARCH: REVISIONS: DATE: FACILITY: DESIGN: DRAWN: 15 A B C D E F G H I A B C D E F G H 16 14 13 12 11 10 9 8 7 6 5 4 3 2 1 1516 14 13 12 11 10 9 8 7 6 5 4 3 2 1 ARCHIVE BAR CODEIthaca, New YorkCORNELLUNIVERSITY FO UN DED5681ADFacilities EngineeringCornell University2004 Sibley Hall8264312Room 260 RenovationsSibley Hall DATE: 10/16/15 - ISSUED FOR CONSTRUCTION October 16, 2015 200CE 260A 260 260 260A 260B 260 260A 260B 260A260B NOTES A-102 C. HOOVER jd 1 2 N N 1 SCALE: SCALE: 1/4" = 1'-0"1/4" = 1'-0" NOTES GENERAL DEMOLITION NOTES: KEYED DEMOLITION NOTES: 1 2 KEYED CONSTRUCTION NOTES: 3 ROOM 260 DEMOLITION N SCALE: 1/4" = 1'-0" N SCALE: 1/4" = 1'-0" 24 0 2 4 8 SCALE: 1/4"=1'-0" 0 2 4 8 SCALE: 1/4"=1'-0" 0 2 4 8 SCALE: 1/4"=1'-0" 0 2 4 8 SCALE: 1/4"=1'-0" ROOM 260 FURNITURE LAYOUT ROOM 260 CONSTRUCTION ROOM 260 INTERIOR ELEVATION INTERIOR ELEVATION CONSTRUCTION, AND FURNITURE LAYOUT, DEMOLITION, ROOM 260 3 4 5 6 7 1 7 7 8 7 2 3 4455 6'-0"6'-0" 3 3 4 5 1.0 ALL EXISTING SPRINKLER HEADS TO REMAIN. 1 3 2 3 3 4 555 3 3 8'-0"8'-0"10'-10"8'-9" 6" 8'-9"8'-6" 1'-0" 6"6"6"6'-1 3/4 " 6'-1 3/4 " 3'-0" 8 6 6 9 9 9 9 9 P1 P1 P1 P1 10 MATCH EXISTING WALL. PAINT TO MATCH ADJACENT WALLS. INFILL OPENING WITH CONCRETE BLOCK TO VINYL COVE BASE ON NEW PARTITIONS, EXISTING WALLS AND PARTITIONS. PART NUMBER EH-1818. COUNTERTOP 24” WIDE THIS LOCATION ONLY. USE BRACKETS FROM RAKKS TYPICAL. USE BRACKETS FROM RAKKS, PART NUMBER EH-1824. COLOR AND FINISH SAMPLE FOR APPROVAL BY OWNER. TOPS 30” WIDE SHALL BE SQUARE EDGED, WHITE LAMINATE W/ SATIN FINISH. SUBMIT NEW COUNTERTOPS TO BE PROVIDED WHERE SHOWN. COUNTERTOPS UNIT. 6’-0 X 8’-0 OPENING; OWNER SHALL SUPPLY AND INSTALL STOREFRONT 6’- 1 ¾”W. X 8’-1” ROUGH OPENING. CONTRACTOR TO PROVIDE FINISHED GLASS STOREFRONT UNITS NOT IN CONTRACT. VERIFY WITH OWNER 10” BOTTOM RAIL. CLEAR SAFETY GLASS ALL LOCATIONS. NEW INTERIOR PARTITIONS UP TO CEILING, TYP. BY OWNER; ENSURE NO GAPS EXCEED ¼”. SAND EXISTING HARDWOOD AND REFINISH. PATCH & REPAIR AS REQ’D ALUMINUM ENTRANCE DOOR AND FRAME. PROVIDE NEW OPENING AND INSTALL NEW CLEAR, ANODIZED 10 EXISTING BLINDS TO REMAIN. PROTECT THROUGHOUT CONSTRUCTION. HARDWOOD FLOOR. REMOVE EXISTING 3/4” PLYWOOD SUB-FLOOR AND EXPOSE ORIGINAL DEMOLISH EXISTING PARTITIONS, TYP. DEMOLISH EXISTING DOOR CUT OPENING FOR NEW DOOR; FINISHED OPENING 3'-0". WARNING: IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT HIS SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. CIVIL: ELEC: MECH: ARCH: REVISIONS: DATE: FACILITY: DESIGN: DRAWN: 15 A B C D E F G H I A B C D E F G H 16 14 13 12 11 10 9 8 7 6 5 4 3 2 1 1516 14 13 12 11 10 9 8 7 6 5 4 3 2 1 ARCHIVE BAR CODEIthaca, New YorkCORNELLUNIVERSITY FO UN DED5681ADFacilities EngineeringCornell University2004 Sibley Hall8264312Room 260 RenovationsSibley Hall DATE: 10/16/15 - ISSUED FOR CONSTRUCTION October 16, 2015 DN 200CE 260A 260 253 DN 253 260 260A 260B F F SSJ F F F SSJ NOTES 1 N SCALE: 1/4" = 1'-0" NOTES KEYED DEMOLITION NOTES: 1 2 KEYED CONSTRUCTION NOTES: 1 ROOM 260 DEMOLITION N SCALE: 1/4" = 1'-0" 2 E-102 jd H.P. TRAN 0 2 4 8 SCALE: 1/4"=1'-0" 0 2 4 8 SCALE: 1/4"=1'-0" ROOM 260 NEW WORK NEW WORK AND DEMOLITION ROOM 260 1 1 1 2 3 3 WIREMOLD 700 4 4 4 1 11 1 1 2 2 8 2 3 3 4 4 42" AFF 5 JUNCTION BOX. EXISTING FIRE ALARM MANUAL PULL STATION. EXISTING FCI FIRE ALARM HORN/STROBE. EXISTING FCI FIRE ALARM 5 6 6 EXTEND EXISTING CONDUIT AND WIRING AS REQUIRED. REFER TO NEW WORK DRAWING FOR NEW LOCATION. MODIFY AND EXISTING RECESS MOUNTED RECEPTACLE TO BE REMOVED AND RE-USED. REFER TO NEW WORK DRAWING FOR THE NEW LOCATION. MODIFY EXISTING SURACE RACEWAY AND POWER WIRING AS REQUIRED. TO REMOVE AND RELOCATE EXISTING SURFACE MOUNTED RECEPTACLE. TO ACCOMMODATE THE REMOVAL OF THE WALL, ELECTRICAL CONTRACTOR EXTEND EXISTING CONDUIT AND WIRING AS REQUIRED. REFER TO NEW WORK DRAWING FOR NEW LOCATION. MODIFY AND EXISTING WALL MOUNTED LUMINAIRE TO BE REMOVED AND RE-USED. EXTEND EXISTING CONDUIT AND WIRING AS REQUIRED. REFER TO NEW WORK DRAWING FOR NEW LOCATION. MODIFY AND EXISTING PENDANT MOUNTED LUMINAIRE TO BE REMOVED AND RE-USED. 7 7 7 (TYPICAL). EXISTING PHONE/DATA BOX TO REMAIN. (TYPICAL). EXISTING RECEPTACLE TO REMAIN. MOUNTING STEMS FOR THIS LUMINAIRE. CIRCUIT AS INDICATED. INSTALL RELOCATED PENDANT MOUNTED LUMINAIRE. PROVIDE (2) NEW KEYED NOTE 4. INSTALL RELOCATED RECESS MOUNTED RECEPTACLE. SEE DEMOLITION CR-2-32-A-120V-EB8. CIRCUIT AS INDICATED. PROVIDE A NEW PENDANT MOUNT COOPER LIGHTING/METALUX CAT. NO. (585) 202-3602. TIM McGEE FROM WEST FIRE SYSTEMS, INC. FOR PRODUCT INFORMATION CIRCUITRY. PROVIDE TESTING AND LABELING AS REQUIRED. CONTACT MOUNT FIRE ALARM STROBE. CIRCUIT TO NEAREST EXISTING NOTIFICATION AT 84" AFF TO THE BOTTOM OF THE LENS, PROVIDE A NEW SURFACE KEYED NOTE 3. INSTALL RELOCATED SURFACE MOUNTED RECEPTACLE. SEE DEMOLITION TO EXISTING LIGHTING CIRCUITRY. KEYED NOTE 2. CIRCUIT TO EXISTING LIGHT SWITCH AS INDICATED AND INSTALL RELOCATED WALL MOUNTED LUMINAIRE. SEE DEMOLITION TO EXISTING LIGHTING CIRCUITRY. KEYED NOTE 1. CIRCUIT TO EXISTING LIGHT SWITCH AS INDICATED AND INSTALL RELOCATED PENDANT MOUNTED LUMINAIRE. SEE DEMOLITION EXISTING SPRINKLER HEAD TO REMAIN. 8