HomeMy WebLinkAboutUris LibraryPLOT DATE: Jun a a C?) NEW SOFFIT - BASEMENT STAIR ELL BOOSA Scale: 1/4" = 1'-0" BASEMENT KEY PLAN J:\PROJECTS-Ithaca\2011\11103 CORNELL - NCP\Uris Library 2010\CAD\11103-2010--AMEP.dwo SCALES ON THIS DRAWING ACCURATE WHEN PLOTTED TO: ARCH El (30X42 IN.) EXISTING 1-5/8" U—TRACK MTL. CHANNELS (BEYOND) 12 GA. WIRE TIES SUSPENDED FROM STRUCT. ABOVE (ALL FOUR CORNERS) —1/2" MTL. FRAMING CHANNELS. SPAN BETWEEN EXISTING SUPPORTS (4—SIDES) 5/8" TYPE "X" GWB CONTINUOUS AROUND PERIMETER THREADED FASTENERS TO MTL. FRAMING EXISTING (RATED) CEILING ASSEMBLY. CEILING TILE ADHERED TO 1/2" GYPSUM BOARD NAILED TO 7/8" ALUM. V—GROOVE CHANNELS REMOVE AND REPLACE CEILING TILES AS REQUIRED FOR ACCESS PANEL INSTALLATION/RESTORATION ACCESS PANEL 2'—O" x 2-0" DOOR TYPICAL NOTE: SEE T2—xx.CA_CP DRAWINGS FOR ADDITIONAL LOCATIONS. PROVIDE ALL COSTS IN BASE BID. NEW ACCESS PANEL - EXISTING GWB CEILING Scale: NONE 4'-0"± VERIFY 1' SHAFT WALL LINER ROTATED SECTION �cvra..a�wcysv:.x.�.mrs;�.-rdsrcO+r:-,, W csOwN44 1+.w voor-N=A.+aco• ,:nht,rofico .rrtacwomrrsevll�*rvr'w,s vas�sr?xTiLVSNT'+'. J RUNNER 25 GAUGE CH (TYPICAL) SHAFTWALL STUD NEW SOFFIT DETAIL 2� Scale: NONE (3) LAYERS 5/8" GWB (2) LAYERS 5/8" GWB GENERAL NOTES 1. REFER TO DRAWING T1—AMEP. IBM QP, 4ge 115 METRO PHONE: ARCHI-TECHNOLOGY, LLC www.archi-technology.com PARK ROCHESTER, NY 14623 585.424.1952 Fax: 585.424.4239 B SLEY DESIGN r ASSOCIATES Architecture, Engineering, Landscape Architecture, P.C. Ph 315.472.6980 5789 Widewaters Parkway Fax 315.472..3523 Dewitt, New York 13214 E-mail HDAOHeardsley.com IiICLIENT: Cornell University CONNECTIVITY PROJECT 0 110 '' XPNETWORK CD 06/29/12 CONSTRUCTION DOCUMENTS 100 DD 05/31/12 100% DD SUBMISSION 50 DD 50% DD SUBMISSION 20 SD 20% SD SUBMISSION PSD 08/15/11 PRELIMINARY SD SUBMISSION MARK DATE DESCRIPTION CONSTRUCTION DOCUMENTS ISSUE DATE: 06/29/12 tc *rni„.t... ..OF NEIN y ..'w- i O6315'3 4, sio0,‘• AT PROJECT NO: 11103-2010 OWNER PROJECT NO: 754 DRAWN BY: LP/EL/PKB CHECKED BY: JLB PROJECT MANAGER: GHS SHEET TITLE: ARCHITECTURAL DETAILS A4 >- m 0 0_ I'l t\m f\A1 r F. .- hO n(11'..) GENERAL PROJECT NOTES A. REFER TO A-, E-, AND M -SERIES DRAWINGS FOR AMEP SYMBOLS AND ABBREVIATIONS. B. REFER TO SPECIFICATION (SPEC) SECTION: DIVISION (DIV) 01 WORK UNDER CONTRACT. C. THIS INFORMATION REPRESENTS EXISTING CONDITIONS BASED ON ORIGINAL DRAWINGS AND OBSERVED SITE CONDITIONS. THE CONTRACTOR SHALL FIELD VERIFY EXACT ROUTING, DIMENSIONS AND QUANTITIES. THE CONTRACTOR SHALL DISCONNECT, REMOVE AND RECYCLE/DISPOSE OF ALL EXISTING CABLING AND DEVICES THAT ARE NOT SCHEDULED FOR REUSE. D. RACEWAY, CONDUIT, CABLING AND ELECTRICAL/MECHANICAL PATHS ARE SHOWN FOR REFERENCE ONLY. EACH CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS AND SHALL DETERMINE BEST PATHS FOR NEW INSTALLATION THAT WILL CAUSE THE LEAST DISTURBANCE TO OCCUPIED SURROUNDINGS AND BUILDING OPERATIONS (INCLUDING EVENING CLASSES). E. EACH CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND PERFORM EXPLORATORY INVESTIGATIONS FOR CONCEALED CONDITIONS AS REQUIRED. EQUIPMENT LOCATIONS AND ROUTES ARE APPROXIMATE AND MINOR ADJUSTMENTS TO THE INSTALLATION WILL BE REQUIRED TO AVOID CONFLICTS WITH EXISTING EQUIPMENT, APPARATUS, AND OCCUPANTS' FURNITURE AND PERSONAL BELONGINGS. F. ALL DRAWINGS ARE SCHEMATIC IN NATURE. THE CONTRACTOR SHALL PROVIDE OFFSETS, ENTRANCE END FITTINGS, RADIUS FITTINGS, HANGERS, ANCHORS, SUPPORT, WIRING AND ACCESSORIES NECESSARY FOR A COMPLETE, OPERATIONAL INSTALLATION. G. IT IS THE RESPONSIBILITY OF EACH CONTRACTOR TO COORDINATE WORK SHOWN ON THEIR CONTRACT DOCUMENTS WITH THE WORK OF OTHER TRADES PRIOR TO SCHEDULING, SHUTDOWN, DEMOLITION, FABRICATION OR INSTALLATION OF ANY WORK OR EQUIPMENT. EQUIPMENT OR DEVICES THAT CANNOT CHANGE LOCATION SHALL TAKE PRECEDENCE OVER THOSE THAT CAN CHANGE LOCATION. H. ALL TRADES AND CONTRACTS ARE RESPONSIBLE TO REVIEW SITE-SPECIFIC CLASSROOM SCHEDULING (DAILY AND WEEKLY), SPECIAL EVENTS/CONFERENCES, UNIVERSITY ACADEMIC CALENDARS, UNIVERSITY CLOSING AND HOLIDAYS. FACTOR WORK SCHEDULING AND MANPOWER LOADING IN SUCH A WAY SO, AS TO MINIMIZE STUDENT AND STAFF DISRUPTIONS. I. PROVIDE SCHEDULES AND ONGOING PROGRESS REPORT SUBMITTALS FOR DEMOLITION AND NEW CONSTRUCTION AS CALLED FOR. REFER TO DIV 01 - SUBMITTAL PROCEDURES, AND DIV 01 - PROJECT MEETINGS SPECIFICATION SECTIONS. J. ALL TRADES AND CONTRACTS ARE RESPONSIBLE FOR THEIR OWN DEMOLITION, TEMPORARY FACILITIES, SAFETY PROGRAMS, PATCHING, PAINTING, FIRESTOP, TRASH REMOVAL/DISPOSAL, ROUTINE CLEANING, SPECIAL TELECOMMUNICATION ROOM CLEANING AND FINAL CLEANING, AS CALLED FOR. REFER TO SPEC SECTIONS IN DIV 01 THROUGH AND INCLUDING DIV 09 AS APPLICABLE. K. WHEN DRY CUTTING PLASTER, GYPSUM, CONCRETE MASONRY UNITS OR PLYWOOD - PROVIDE APPROPRIATE DUST AND NOISE CONTROL TEMPORARY PARTITIONS AND MAINTAIN EGRESS AND FIRE ALARM SYSTEM OPERATION. PROVIDE ZIP -WALL DUST BARRIERS OR OTHER APPROPRIATE PROTECTION TO LOCALIZE CLEANUP AND MINIMIZE THE EXTENTS OF FIRE ALARM SHUTDOWNS AND PREVENT FALSE FIRE ALARMS FOR SMALL SCALE CUTTING AND DEMOLITION. WHERE GENERAL CONSTRUCTION WILL CREATE DUST AND DEBRIS, THE CONTRACTOR SHALL PROVIDE PROTECTIVE COVERING FOR FURNITURE, FURNISHINGS AND EQUIPMENT. L. "ERL" ADJACENT TO A DEVICE, FIXTURE OR PIECE OF EQUIPMENT INDICATES AN EXISTING ITEM TO BE RELOCATED. DISCONNECT AND REMOVE THE ITEM. REMOVE ALL UNNECESSARY RACEWAY AND WIRING. REINSTALL AND RECONNECT ITEM AS REQUIRED. M. "ETR" ADJACENT TO A DEVICE, FIXTURE OR PIECE OF EQUIPMENT INDICATES EXISTING ITEM TO REMAIN. MAINTAIN EXISTING CONNECTIONS TO EQUIPMENT UNLESS NOTED OTHERWISE. N. PROVIDE QUALIFIED TRADES PERSON OR CONTRACTOR TO RESTORE FINISHED WALLS, CEILING AND FLOORS TO ORIGINAL CONDITION AS CALLED FOR IN DIV 01 - CUTTING AND PATCHING. 0. WHERE GENERAL CONSTRUCTION WILL CREATE DUST AND POTENTIAL FALSE SMOKE DETECTOR SIGNALS, THE CONTRACTOR SHALL COORDINATE FIRE ALARM SYSTEM SHUTDOWNS WITH CORNELL EH&S. VISIT SITE PRIOR TO SUBMITTING WRITTEN SHUTDOWN REPORT - TO CONFIRM EXISTING SMOKE DETECTOR LOCATION AND OWNERS' DEVICE/ZONE ADDRESS WITH RESPECT TO LOOK -AHEAD WORK SCHEDULE. REFER TO EXISTING FIRE ALARM DEVICE SCHEDULE, AS APPLICABLE. FALSE FIRE ALARMS CAUSED BY CONSTRUCTION DUST WILL NOT BE TOLERATED. CONTRACTORS ARE RESPONSIBLE TO PAY FOR ANY FINES IMPOSED BY ITHACA/CAYUGA HEIGHTS FIRE DEPARTMENT FOR UNNECESSARY FALSE FIRE ALARMS. P. RESTORE AND MAINTAIN AREA FIRE RESISTANCE RATING OF FLOOR AND WALLS. RESTORE AND MAINTAIN AREA SMOKE BARRIERS RATING OF WALLS AND SOFFITS WITH SIMILAR MATERIALS AS CALLED FOR IN DIV 01 - CUTTING AND PATCHING. ALSO REFER TO SPEC SECTION DIV 07 - PENETRATION FIRESTOPPING. Q. FIRESTOP ALL NEW AND EXISTING TELECOM WALL PENETRATIONS AND CONDUIT SLEEVES TO MAINTAIN AREA FIRE RESISTANCE RATING. R. MAINTAIN EXISTING SERVICES AT ALL TIMES DURING NORMAL BUILDING OPERATIONS. PROVIDE TEMPORARY SERVICES AS REQUIRED, OR AS DIRECTED. EXISTING DATA/COMMUNICATIONS CABLE AND OUTLETS SHALL REMAIN DURING THE INSTALLATION OF NEW CABLING AND DEVICES TO MINIMIZE DOWN TIME. COORDINATE CUTOVER TO NEW SYSTEM WITH PROJECT MANAGER. REFER TO SPEC SECTION 27 - COMMISSIONING. - S. ALL TRADES AND CONTRACTS SHALL REPAIR DAMAGED CEILINGS (ANY TYPE), REPLACE LAY -IN CEILING TILES AND GRID WHERE NOTCHED OR DAMAGED FOR EXISTING REMOVALS OR NEW INSTALLATIONS, AS CALLED FOR IN DIV 01 - CUTTING AND PATCHING. REFER TO EXISTING CEILING SCHEDULE ON NEW WORK T2 DRAWINGS. T. PROVIDE BLANK COVERS, FIRE SEAL, CUTTING, AND PATCHING AS REQUIRED TO REPAIR HOLES, UNPAINTED AREAS, OR OTHER PHYSICAL DEFECTS CAUSED BY THE REMOVAL AND INSTALLATION OF EQUIPMENT AND DEVICES. U. PROVIDE ELECTRONIC SUBMITTAL(S) ON ACTUAL PRODUCTS USED VIA PROJECT WEBSITE. INCLUDE COPY OF APPROVED SUBMITTAL WITH CLOSE-OUT DOCUMENTS (IN HARD COPY 0/M MANUAL), REFER TO SECTIONS: 01 33 00 - SUBMITTALS; 01 78 39 - RECORD DOCUMENTS; AND 01 77 00 - PROJECT CLOSEOUT AS APPLICABLE. V. DIVISION 27 CONTRACTOR SCOPE: FOR ALL EXISTING SR -4 RACEWAY, THOROUGHLY WIPE DIRT AND DUST FREE FROM ALL REUSED EXISTING SR -4 SERIES RACEWAYS, REMOVE METAL FILINGS FROM INSIDE RACEWAYS AT ALL CONDUIT CONNECTIONS. WHEN RACEWAY IS SHARED WITH ELECTRIC, PROVIDE/MAINTAIN METALLIC SEPARATION BARRIERS, PER NEC CODE. AT LOCATIONS WITH EXISTING ROUND MODULAR OR 4 -PRONG OUTLETS, REMOVE/REPLACE EXISTING SR -4 COVER WITH NEW DEVICE COVER TO CLOSE THE OPEN HOLE (AND PRIME AND PAINT TO MATCH). AT LOCATIONS WITH EXISTING OPENINGS IN EXISTING SR -4, REMOVE/REPLACE EXISTING SR -4 COVER WITH NEW DEVICE COVER TO CLOSE THE OPEN HOLE (AND PRIME AND PAINT TO MATCH). REPLACE EXISTING BENT/DAMAGED OR MISSING SR -4 COVERS (ASSUME 10' OF NEW COVER FOR EVERY 150' OF EXISTING RACEWAY, EVEN IF NOT SPECIFICALLY INDICATED ON THE DRAWINGS). W. CUTOVER OF ACTIVE BACKBONE SERVICES TO BE PERFORMED BY CIT FIELD SERVICES UNLESS OTHERWISE NOTED. END OF NOTES GENERAL REMOVAL NOTES A. AFTER VOICE/DATA CUTOVER, REMOVE EXISTING SURFACE MOUNTED COMMUNICATION OUTLETS AND ASSOCIATED CABLING UNLESS OTHERWISE NOTED TO REMAIN. PATCH AND PAINT AS CALLED FOR. PROVIDE BLANK COVER PLATE TO MATCH EXISTING AS REQUIRED. AFTER VOICE/DATA CUTOVER, AT EXISTING RECESSED COMMUNICATION OUTLETS PROVIDE BLANK COVER PLATE. REMOVE ALL ASSOCIATED CABLING IN ITS ENTIRETY. PROVIDE BLANK COVER PLATE ON ALL EXISTING UNUSED OPENINGS AS WELL. WHEN .�... _. ......-. ._. SURFACE RACEWAY �. ,... ..�. CALLED REMAIN .. r- .. REUSE, REMOVE EXISTING COMMUNICATIONS FACEPLATES AND OLD WHEN EXISTING SURFACE RACEWAY IS CALLED TO REMAIN FOR REUSE, REMOVE EXISTING CABLING IN THEIR ENTIRETY, AFTER VOICE/DATA CUTOVER, AS CALLED FOR." PROVIDE BLANK PLATE OR REPLACEMENT COVER SECTIONS TO CONCEAL OPENINGS. RECYCLE REMOVED METALLIC COMPONENTS, RACEWAYS AND CABLING TO THE GREATEST EXTENT POSSIBLE. COORDINATE DUMPSTER LOCATION IN ADVANCE WITH THE PROJECT MANAGER. AFTER VOICE/DATA CUTOVER, REMOVE EXISTING CABLING BACK TO SOURCE. REMOVE ALL ASSOCIATED ANCHORS, TERMINAL BLOCKS, AND SPLICE CASES. COORDINATE THE CUTOVER OF ALL REMAINING SYSTEMS WITH THE PROJECT MANAGER. AFTER VOIkE/DATA CUTOVER, DISCONNE T AND REMOVE i LRMINAL BLOCKS, ENCLOSURE, PLYWOOD BACKBOARD, AND ALL ASSOCIATED CABLING IN THEIR ENTIRETY. PRIOR TO REMOVAL, THE CONTRACTOR SHALL TEST ALL PAIRS FOR SERVICE. COORDINATE THE CUTOVER OF ALL REMAINING SYSTEMS WITH THE PROJECT MANAGER. PATCH AND PAINT WALLS TO MATCH EXISTING AREA IN CORRIDORS AND OFFICE AREAS. G. DISCONNECT AND REMOVE ALL EXISTING DEVICES/WIRING SHOWN FOR REMOVAL, BACK TO SOURCE. MAKE ALL CONNECTIONS NECESSARY TO MAINTAIN EXISTING SYSTEMS WHERE PARTIAL DEMOLITION IS REQUIRED DUE TO SCHEDULING. H. REPLACE CEILING TILES AND CEILING GRID, TO MATCH EXISTING, WHERE NOTCHED FOR EXISTING CONDUITS AND RACEWAYS THAT ARE CALLED TO BE REMOVED. END OF NOTES GENERAL NEW ORK NOTES A. CABLE TRAY, CONDUIT AND RACEWAY ROUTING SHOWN IS DIAGRAMMATIC ONLY. CONTRACTOR TO FIELD VERIFY EXISTING CONDITIONS AND ROUTE PATHWAYS TO AVOID MECHANICAL AND STRUCTURAL CONFLICTS. NOT ALL REQUIRED JUNCTION BOXES AND OFFSETS ARE SHOWN, PROVIDE OFFSETS AND PULLBOXES AS REQUIRED. B. CONTRACTOR SHALL REMOVE AND REPLACE SPLINE CEILINGS TO ACCESS WORK AREAS AS INDICATED ON THE T2-x.CP_CA DRAWINGS. CONTRACTOR SHALL ALSO PROVIDE ACCESS PANELS AT ALL NEW PULLBOXES INSTALLED IN SPLINE CEILINGS. C. WHERE EXISTING PATHWAYS ARE TO REMAIN AND BE REUSED, THE CONTRACTOR SHALL RE -SUPPORT AND PROVIDE RADIUS FITTINGS AS NEEDED TO ENSURE COMPLIANCE WITH SPECIFICATIONS AND UNIVERSITY STANDARDS. D. A PULLBOX SHALL BE INSTALLED FOR RACEWAYS, SIZED AS INDICATED, IN RACEWAY INCREMENTS OF 100 FEET, AND WHEN THE ACCUMULATIVE BEND RADII IS EQUIVALENT TO 180 DEGREES. INSTALL CONDUITS THROUGH PULLBOXES ONLY AS DEPICTED ON STANDARD DETAILS, AND T2-x.CA_CP SERIES DRAWINGS. E. LOCATIONS OF PULLBOXES SHOWN ARE APPROXIMATE - PULLBOXES SHALL BE LOCATED IN AN AREA THAT IS READILY ACCESSIBLE. FIELD VERIFY THE EXACT LOCATIONS. F. THE USE OF CONDUIT BODIES (SMART LB'S) THAT HAVE BUILT-IN BEND RADIUS CONTROL DESIGNED FOR TELECOMMUNICATIONS APPLICATIONS ARE PERMITTED IN ALL COPPER, FIBER AND UTP RISER CONDUITS USED FOR TELECOMMUNICATIONS PATHWAYS. G. THE PULLING TENSION OF UTP CABLES SHALL NOT EXCEED 25 LBS PER CABLE. PROVIDE ADDITIONAL INSTALLERS AT CORNERS AND UTILIZE APPROVED LUBRICANT AS REQUIRED. H. COORDINATE THE ROUTING OF ALL PATHWAYS WITH EXISTING DUCT WORK, PIPING, ELECTRICAL CONDUITS, AND OTHER EXISTING OBSTRUCTIONS. I. PROVIDE ALL REQUIRED OFFSETS, FABRICATION AND FITTINGS REQUIRED FOR THE INSTALLATION OF CABLE TRAY, CONDUIT, SURFACE RACEWAY, AND CABLE RUNWAY. CABLE TRAY AND CONDUIT SHALL BE INSTALLED CONCEALED UNLESS OTHERWISE NOTED. PAINT EXPOSED CONDUITS, SUPPORTS, PULLBOXES, ETC. REFER TO DIV 09 - INTERIOR PAINTING. J. K. END OF NOTES J:\PROJECTS-Ithaca\2011\ 11103 CORNELL - NCP\Uris Library 2010\CAD\ 1 1 103-2010--T-GEN.dwq GENERAL DRAWING NOTES -EXISTING CONDITIONS/REMOVALS- A. ITEMS SHOWN GRAYSCALE ARE EXISTING TO REMAIN UNLESS SPECIFIED OTHERWISE. B. ITEMS SHOWN DASHED -BOLD ARE TO BE REMOVED UNLESS SPECIFIED OTHERWISE. C. EXISTING CONDITIONS HAVE BEEN DOCUMENTED TO THE EXTENT POSSIBLE AT TIME OF SURVEY. TRUST BUT VERIFY ALL EXISTING CONDITIONS ARE AS INDICATED ON "T" SERIES DRAWINGS. REDLINE ON RECORD DRAWINGS ANY DEVIATIONS. END OF NOTES GENERAL DRAWING NOTES -HORIZONTAL CABLING - A. ITEMS SHOWN BOLD ARE NEW WORK UNLESS SPECIFIED OTHERWISE. B. ITEMS SHOWN IN GRAYSCALE ARE EXISTING TO REMAIN UNLESS SPECIFIED OTHERWISE. C. PROVIDE MANUFACTURER ENGINEERED SOLUTION FOR SMOKE AND FIRE STOPS. D. REFER TO DRAWINGS T1 -CL, T1 -FL, T3-xx, AND SPECIFICATIONS 27 13 00, 27 15 00, 27 05 00, 27 05 53 FOR ADDITIONAL REQUIREMENTS. E. PROVIDE CAT 6A CABLING FOR ALL OUTLETS LOCATIONS WITH A WAP OUTLET DESCRIPTOR. PROVIDE CAT 6 CABLING FOR ALL OTHER OUTLET LOCATIONS WITH NEW CABLING INDICATED. F. ALL NEW CAT 6 AND CAT 6A CABLING SHALL BE NON PLENUM CMR RATED. G. BACKBONE CABLING AND HORIZONTAL CABLING SHALL NOT OCCUPY THE SAME CONDUIT / CABLE TRAY UNLESS APPROVED BY OWNER. END OF NOTES GENERAL DRAWING NOTES -PATHWAYS- A. ITEMS SHOWN BOLD ARE NEW WORK UNLESS SPECIFIED OTHERWISE. B. ITEMS SHOWN IN GRAYSCALE ARE EXISTING TO REMAIN UNLESS SPECIFIED OTHERWISE. C. REFER TO DRAWINGS T2-x.CA_CP AND T1 -PL FOR HORIZONTAL PATHWAYS. D. REFER TO A-, M-, E -SERIES DRAWINGS FOR ADDITIONAL REQUIREMENTS. E. REFER TO T1 -PL DRAWING FOR ADDITIONAL REQUIREMENTS. F. PATCH/FIRESTOP ALL EXISTING AND NEW CONDUIT CABLE PENETRATIONS IN CORRIDOR WALLS. G. REMOVE LIGHTS AS REQUIRED TO ACCESS ABOVE CEILING LOCATIONS. REPORT ANY EXISTING DAMAGED OR NON -OPERATIONAL LIGHTS TO OWNER'S REPRESENTATIVE PRIOR TO LIGHT REMOVAL. H. EMT TO BE USED IN ALL NEW CONDUIT INSTALLATIONS IF POSSIBLE. FLEX CONDUIT TO BE USED AS LAST RESORT IF FIELD CONDITIONS PREVENT USE OF EMT. IF FLEX CONDUIT IS TO BE USED, IT SHALL BE INCREASED TO ONE TRADE SIZE LARGER THAN REQUIRED FOR EMT. I. PROVIDE BUSHINGS FOR ALL CONDUIT ENDS INSIDE EXISTING & NEW PULLBOXES. J RE -CONNECT ANY EXISTING CONDUIT BEING REUSED THAT HAS SEPARATED FROM FITTING. K. PERMANENT LABEL NEAT AND LEGIBLE, ALL NEW AND EXISTING PULLBOX COVERS WITH "COMMUNICATIONS ONLY". L ALL NEW RACEWAY TO BE METALLIC UNLESS OTHERWISE NOTED. M. PROVIDE SPACE SAVER CONDUIT CONNECTORS IN NEW OUTLET BOXES, RACEWAYS AND PULLBOXES. REFER TO SECTION 27 05 28. N. WHERE INDICATED ON THE DRAWINGS, PAINT EXPOSED CONDUITS, SUPPORTS, PULLBOXES, ETC. WHERE INSTALLED IN FINISHED (PUBLIC) NON-MECHANICAL AREAS. REFER TO DIV 09, INTERIOR PAINTING. 0. ALL OUTLETS THAT ARE CALLED TO BE RECESS MOUNTED SHOULD BE IN A DOUBLE GANG BOX. ALL OUTLETS THAT ARE FED VIA SR -2 RACEWAY SHOULD BE ASSUMED TO BE SINGLE GANG SURFACE MOUNT OUTLET BOXES UNLESS OTHERWISE NOTED. EMERGENCY WALL PHONE LOCATIONS THAT I✓ FOR ALL AND WALL PHONE HA CALL FOR SURFACE RACEWAYS ASSUME SR -7 AND ASSOCIATED FITTINGS. Q. ALL EXISTING AND NEW PATHWAYS THAT ARE 2" AND LARGER, AND LONGER THAN 10' SHALL BE BONDED. R. ALL CABLE TRAYS SHALL BE ELECTRICALLY CONTINUOUS. COMMUNICATIONS PATHWAYS THAT END IN CLOSE PROXIMITY TO THE CABLE TRAY SHALL BE BONDED TO THE CABLE TRAY. S. ALL PATHWAYS TERMINATING IN THE MTR\ITR SHALL BE BONDED TO THE TMGB\TGB. T. CABLES SUPPORTED IN J HOOKS SHALL FOLLOW THE J HOOK MANUFACTURERS REQUIREMENTS FOR MOUNTING, SPACING, AND FILL CAPACITY. END OF NOTES ACCESS CONTROL SYMBOLS LEGEND CARD READER LOCK DOOR CONTACT (POSITION SWITCH) SINGLE INPUT READER INTERFACE MODULE El DUAL INPUT READER INTERFACE MODULE ISO INTELLIGENT SYSTEM CONTROLLER (CONTROL PANEL) PATHWAY SCHEDULE - NEW WORK CABLE FILL BASED ON CABLE OD O = 0.24 DESIGNATION DESCRIPTION MANUFACTURER PART NO. APPROXIMATE OUTSIDE DIMENSION APPROXIMATE INSIDE DIMENSION CABLE FILL CAPACITYO MIN. BEND RADIUS .75" C =_ CONDUIT SEE SPEC. SECTION 27 05 28 .75" DIA. 4 4.5" 1" C 1" DIA. 7 6" 1.25" C 1.2511 DIA, 13 7.5" 1.5" C 1.5" DIA. 18 9" 2" C 2" DIA. 29 12" 2.5" C 2.5" DIA. 51 25" 3" C 3" DIA. 78 30" 4" C 4" DIA. 130 40" ETR SR -1 NOT USED ELEVATOR PHONE SR -2 ** SURFACE RACEWAY SEE SPEC. SECTION 27 05 28 2400 SERIES SEE SPEC. SECTION 27 05 28 12 GWB SR -3 ** SURFACE RACEWAY 3000 SERIES 32 SR -4 ** SURFACE RACEWAY 4000 SERIES 63 SR -4D ** SURFACE RACEWAY (DIVIDED) 4000D SERIES 30 SR -5 ** SURFACE RACEWAY 5400 SERIES 32 SR -6 ** SURFACE RACEWAY 6000 SERIES 140 SR -6D ** SURFACE RACEWAY (DIVIDED) 6000D SERIES 63 SR -7 SURFACE RACEWAY 700 SERIES 2 SINGLE -MODE OPTICAL FIBER CT -A ENCLOSED TRAY NOT USED 2"x6" 106 TELECOMMUNICATION GROUND BUS BAR CT -B 2"x12" 211 CT -C 2"x18" 316 CT -D 2"x24" 419 CT -E 4"x12" 419 CT -F 4"x18" 632 CT -G 4"x24" 844 CT -H 611x6" 318 CT -I WIRE DUCT NOT USED 6"x6" 318 CT -J 4"x6" 212 CT -K 4"X911 318 NOTES: 0 40% MAXIMUM FILL FOR CATEGORY 6 INDICATED (PER TIA / EIA 569-A). - CAT6A CABLING HAS AN OD OF 0.285. - REDUCE FILL RATIO BY 6% FOR EACH 90° BEND - ENSURE THAT FILL RATIOS ARE NOT EXCEEDED 3/4" CONDUIT SHALL ONLY BE ALLOWED AS SPECIFICALLY NOTED ON DRAWINGS. ** REDUCE CAPACITY BY 50% FOR THE FOLLOWING CONDITIONS: - WHEN CONNECTORS ARE MOUNTED WITHIN RACEWAY - WHEN NON -RADIUS FITTINGS RESTRICT CROSS-SECTIONAL AREA - WHEN RACEWAY IS DIVIDED AND SHARED WITH ELECTRIC ALTER EXISTING SURFACE RACEWAY TO PROVIDE AT LEAST TWO 16" SECTIONS OF REMOVABLE COVERS TO ALLOW CABLE ROUGH -IN WITHOUT CONFLICT WITH EXISTING FURNITURE CONFIGURATIONS. ALSO REFER TO GENERAL NOTE "Z" ON T -GEN DRAWING FOR ADDITIONAL SCOPE FOR SURFACE RACEWAYS. WHERE REQUIRED BY RACEWAY CAPACITY, OR AS DIRECTED, PROVIDE SURFACE MOUNT EXTENSION BOX ON EXISTING RACEWAY OPENING TO PROVIDE ADEQUATE CAPACITY AND BEND RADIUS. ALSO REFER TO RACEWAY DERATING REQUIREMENTS AT LEFT. WHERE REQUIRED BY RACEWAY CAPACITY, OR AS DIRECTED, PROVIDE RETROFIT ENTRANCE END FII I ING OR ALTER EXISTING BACKFED CONDUIT WITH A NEW SPACE SAVER CONNECTOR TO PROVIDE ADEQUATE CAPACITY AND BEND RADIUS FOR NEW CABLING. ALSO REFER TO RACEWAY DERATING REQUIREMENTS AT LEFT. FIELD VERIFY EXISTING CONDITIONS AND PROPOSE ALTERATIONS THAT MINIMIZE SERVICE DISRUPTION DURATION. PROVIDE ALL TEMPORARY PROVISIONS TO MAINTAIN EXISTING SERVICES. CONDUIT AND CABLE TRAY TO BE ROUTED CONCEALED UNLESS OTHERWISE NOTED. SCALES ON THIS DRAWING ACCURATE WHEN PLOTTED TO: ARCH El (30X42 IN.) CEILING SCHEDULE T SUSPENDED LAY -IN CEILING 0 OPEN CEILING 0 SPLINE CEILING ® SUSPENDED PLASTER CEILING 0 SUSPENDED PLASTER CEILING OF SUSPENDED GYPSUM CEILING ABBREVIATIONS ACM ASBESTOS CONTAMINATED MATERIAL AP ACCESS PANEL AHJ AUTHORITY HAVING JURISDICTION AWG AMERICAN WIRE GAUGE ARMM ARMORED RISER 24AWG MULTIPAIR CABLE BDF BUILDING DISTRIBUTION FRAME BICSI BUILDING INDUSTRY CONSULTING SERVICES INTERNATIONAL BSC BIO -SAFETY CABINET CCTV CLOSED CIRCUIT TELEVISION CIT CORNELL INFORMATION TECHNOLOGIES CMP COMMUNICATIONS PLENUM RATED CABLE - NEC CMR COMMUNICATIONS RISER RATED CABLE - NEC CTR CIT SUPPORTED EQUIPMENT CABINET WITH ZONE CABLING DDC DIRECT DIGITAL CONTROL SYSTEM DEMARC VERIZON DEMARCATION POINT DN DOWN DOM DEPARTMENT OWNED AND MAINTAINED EF ENTRANCE FACILITY EH&S ENVIRONMENTAL HEALTH AND SAFETY EM EMERGENCY PHONE EMS ENERGY MANAGEMENT SYSTEM ERL "ERL" ADJACENT TO A DEVICE, FIXTURE OR PIECE OF EQUIPMENT INDICATES AN EXISTING ITEM TO BE RELOCATED. DISCONNECT AND REMOVE THE ITEM. REMOVE ALL UNNECESSARY RACEWAY AND WIRING. REINSTALL AND RECONNECT ITEM AS REQUIRED. MAINTAIN SERVICES AS CALLED FOR. ETR "ETR" ADJACENT TO A DEVICE, FIXTURE OR PIECE OF EQUIPMENT INDICATES AN EXISTING ITEM TO REMAIN. MAINTAIN EXISTING CONNECTIONS TO EQUIPMENT UNLESS OTHERWISE NOTED. EV ELEVATOR PHONE FACP FIRE ALARM CONTROL PANEL FO/OF FIBER OPTIC / OPTICAL FIBER FH FUME HOOD GWB GYPSUM WALL BOARD IEEE INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS ITR INTERMEDIATE TELECOMMUNICATIONS ROOM JB JUNCTION BOX LAN LOCAL AREA NETWORK LEC LOCAL EXCHANGE CARRIER / TELCO LS LIFE SAFETY MM MULTI -MODE OPTICAL FIBER MTR MAIN TELECOMMUNICATIONS ROOM OFNR OPTICAL FIBER NON-METALLIC STRENGTH RISER RATED OSHA OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION PB PULL BOX PP PATCH PANEL RAP RF OTF A I IIINCI. TION PANFI SM SINGLE -MODE OPTICAL FIBER TC TELECOMMUNICATIONS CONTRACTOR TELCO PUBLIC TELEPHONE COMPANY (VERIZON) TGB TELECOMMUNICATION GROUND BUS BAR TMGB TELECOMMUNICATIONS MAIN GROUNDING BAR TIA TELECOMMUNICATION INDUSTRY ASSOCIATION TR TELECOMMUNICATIONS ROOM TYP TYPICAL UNO UNLESS NOTED OTHERWISE UPS UNINTERRUPTIBLE POWER SUPPLY UTP UNSHIELDED TWISTED PAIR VIF VERIFY IN FIELD VOM VERIZON OWNED AND MAINTAINED WAP WIRELESS ACCESS POINT TELECOM SYMBOLS LEGEND (REV. 02/12) DEMO EXISTING NEW DESCRIPTION r IA W TELECOM OUTLET - FLOOR BOX © T ® TELECOM OUTLET - CEILING MOUNTED <1 4 . TELECOM OUTLET - WALL MOUNTED SIZE AS INDICATED CONDUITS - J —J— J -HOOKS - WHERE INDICATED CONDUIT WITH BUSHINGS - TYPE & SIZE AS C 3 t INDICATED PULLBOX: X = SIZE: em. :dam. PB—X PB X PB—X (S) SMALL, (M) MEDIUM, (L) LARGE LxWxH LxWxH LxWxH LxWxH = DIMENSIONS IN INCHES FR CTRT EQUIPMENT CABINET WITH ZONE CABLING AJJ AP AP ACCESS PANEL - CEILING MOUNT xss-# ®SR-# _1sR-# VERTICAL RACEWAY - DOWN (SR -2 UNO) HSR -f BCR-# HSR-# VERTICAL RACEWAY - UP (SR -2 UNO) MCT -X ®CT -x 1,1cf x VERTICAL CABLE TRAY - DOWN I4cr x ICT -X Bcrx VERTICAL CABLE TRAY - UP • • • CONDUIT/SLEEVE - UP 0 0 CONDUIT/SLEEVE - DOWN 4 o 0 CONDUIT/SLEEVE - THRU (BETWEEN FLOORS) HORIZONTAL RACEWAY - SIZED PER PATHWAY I sR # I ® SCHEDULE HORIZONTAL CABLE TRAY - SIZED PER CT -X CT -x CT -X PATHWAY SCHEDULE MARK TTTT I H I 1111 CABLE RUNWAY T ► $ SPLICE CASE 11 COMMUNICATIONS POWER POLE SERVING ZONE OR MTR/ITR BOUNDARY CTR SERVING ZONE BOUNDARY AT PROJECT NO: 11103-2010 NEW / EXISTING OUTLET SUBSCRIPT KEY (REFER TO ADDITIONAL DESCRIPTORS THIS DRAWING) DRAWN BY: LP/EL/PKB "A" ROOM LOCATION CODE "#" EXISTING OUTLET NOTE "xx" EXISTING PATHWAY TYPE TO BE REUSED "}ry" OUTLET DESCRIPTOR "zz" NEW PATHWAY TYPE tj SHEET TITLE: STANDARD SYMBOLS, NOTES, ABBREVIATIONS (T -SERIES) T -GEN YY NEW PATHWAY TYPE KEY CC CONDUIT TO CEILING CF CONDUIT TO FLOOR CL CONDUIT TO CLOSET CI CONDUIT HOMERUN TO ITR/MTR CP CONDUIT TO PULLBOX CT CONDUIT TO CABLE TRAY FW FISHABLE WALL JP J -HOOK TO PULLBOX JS J -HOOK TO SLEEVE JT J -HOOK TO CABLE TRAY PT PULLBOX TO CABLE TRAY SC SURFACE RACEWAY TO CEILING SF SURFACE RACEWAY TO FLOOR SH SURFACE RACEWAY TO HALL (RACEWAY THROUGH ROOM TO HALLWAY PRIMARY HORIZONTAL PATHWAY) SW SURFACE THROUGH WALL DOB NEW DEVICE OPENING IN EXISTING SURFACE RACEWAY, WITH BLANK PLATE (MATCH EXISTING COLOR) NOTE: PROVIDE MINIMUM 1" CONDUIT UNLESS NOTED OTHERWISE. INCREASE SIZE AS REQUIRED PER CABLE FILL CHART. NOTE: PROVIDE MINIMUM SIZE METALLIC RACEWAY BASED ON CABLE FILL CHART UNLESS NOTED OTHERWISE. NOTE: ASSUME PATHWAY TYPE "CP" UNLESS NOTED OTHERWISE. OUTLET DESCRIPTOR KEY ##" HEIGHT ABOVE FINISHED FLOOR (AFF) - EXAMPLE: 48" BAC BUILDING ACCESS CONTROLLER EM EMERGENCY TELEPHONE OUTLET EV ELEVATOR TELEPHONE LINE CONNECTION EMS ENERGY MANAGEMENT FACP FIRE ALARM CONTROL PANEL P WALL MOUNTED PAY -PHONE OUTLET W WALL MOUNTED TELEPHONE OUTLET TO BE MOUNTED AT 48" AFF WAP WIRELESS ACCESS POINT - REFER TO DETAIL AT -27052839. EXISTING OUTLET NOTE KEY A EXISTING DEVICE OR OPENING WITH LEGACY CABLING. REMOVE " CABLING, PAINT/PATCH OR PROVIDE BLANK AS APPLICABLE. EXISTING ONE -GANG BOX AND PATHWAYS TO BE REUSED AS A INDICATED. MAINTAIN EXISTING SERVICES UNTIL AFTER CUTOVER, THEN REMOVE CABLING. EXISTING TWO -GANG BOX AND PATHWAYS TO BE REUSED AS /z\ INDICATED. MAINTAIN EXISTING SERVICES UNTIL AFTER CUTOVER, THEN REMOVE CABLING. EXISTING OUTLET LOCATION IN SURFACE RACEWAY. PATHWAYS TO BE REUSED AS INDICATED. MAINTAIN ANY EXISTING SERVICE UNTIL AFTER CUTOVER, THEN REMOVE CABLING. PROVIDE DEVICE BRACKETS AS REQUIRED. A\ EXISTING PATHWAYS, BOXES, RACEWAYS AND CAT.5, CAT.5E OR CAT.6 CABLES TO REMAIN. EXISTING PATHWAYS, BOXES AND RACEWAYS TO REMAIN. COORDINATE SHUTDOWN AND CONDUIT/CABLE REWORK TO RELOCATE FROM EXISTING TR TO NEW TR PER T1 -PL, T1 -SZ AND APPENDIX A. REASSIGN CABLE PANEL/PORTS AS CALLED FOR. CABLING SYMBOLS LEGEND 2B -101-A 1 CABLE IDENTIFICATION LABEL: 2B COMMUNICATIONS EQUIPMENT ROOM 101 MASTER LOCATION CODE A ROOM LOCATION CODE 1 POSITION r.0.. IPARCHI-TECHNOLOGY, & LLC www.archi-technology.com PARK ROCHESTER, NY 14623 585.424.1952 Fax: 585.424.4239 115 METRO PHONE: r c) 1_, 0 N Q >-- V/ pe z _..11--1 fit Z CO 1--1 _1 U (f)Q ZCe o U �Zc F— D CLIENT: NETWORK 4 Cornell University PROJECT em. :dam. CONNECTIVITY CD 06/29/12 CONSTRUCTION DOCUMENTS 100 DD 05/31/12 100% DD SUBMISSION 50 DD 04/20/12 50% DD SUBMISSION 20 SD 10/14/11 20% SD SUBMISSION PSD 09/14/11 PRELIMINARY SD SUBMISSION MARK DATE DESCRIPTION CONSTRUCTION DOCUMENTS ISSUE DATE: 06/29/12 AT PROJECT NO: 11103-2010 OWNER PROJECT NO: 754 DRAWN BY: LP/EL/PKB CHECKED BY: JLB PROJECT MANAGER: GHS SHEET TITLE: STANDARD SYMBOLS, NOTES, ABBREVIATIONS (T -SERIES) T -GEN r m 91 a. 0 C C C p PLOT DATE: ELL \( NETW • ' K CONNE TIVITY PRSJECT I LI PROJECT SITE PLAN 0LN LIBRARY 2047 PUS ST 2088 WILLARD STRAIGHT HALL 2020 J:\PROJECTS-Ithaca\2011111103 CORNELL - NCP\Uris Library 2010\CAD\11103-2010--T-COVER.dwg 2010 DRAWING INDEX DRAWING DESCRIPTION T -COVER DRAWING INDEX AND PROJECT SITE PLAN T -GEN STANDARD SYMBOLS, NOTES, ABBREVIATIONS (T -SERIES) T1 T1 -SZ TR SERVING ZONES, PLAN VIEWS AND BLDG. SECTION VIEW Tl -PL PATHWAYS LOGICAL RISER DIAGRAMS Ti -CL COPPER LOGICAL RISER DIAGRAMS T1 FL FIBER LOGICAL RISER DIAGRAMS T2 T2-5B.CA CP BASEMENT 5B PATHWAYS AND CABLING T2-4B.CA_CP BASEMENT 4B PATHWAYS AND CABLING T2-3B.CA__CP BASEMENT 3B PATHWAYS AND CABLING T2-2B.CA_CP BASEMENT 2B PATHWAYS AND CABLING T2-B.CA_CP BASEMENT PATHWAYS AND CABLING T2-1.CA CP FIRST FLOOR PATHWAYS AND CABLING T2-2.CA_CP SECOND FLOOR PATHWAYS AND CABLING T2-3.CA_CP CP T HIRD FLOOR PATHWAYS HWAYS AND CABLING T2-4.CA CP FOURTH FLOOR PATHWAYS AND CABLING T2-5.CA CP FII- I H FLOOR PATHWAYS AND CABLING T2-6 10.CA CP SIXTH THROUGH TENTH FLOOR PATHWAYS AND CABLING T3 T3-2BA MTR-2BA ENLARGED PLANS AND ELEVATIONS AMEP AMEP-GEN GENERAL NOTES, SYMBOLS AND ABBREVIATIONS (AMEP SERIES) Ti-AMEP AMEP-AREAS OF WORK AMEP-2BA MTR-2BA PARTIAL PLANS AND KEYNOTES A4 ARCHITECTURAL DETAILS M4 MECHANICAL DETAILS E4 ELECTRICAL DETAILS SCALES ON THIS DRAWING ACCURATE WHEN PLOTTED TO: ARCH El (30X42 IN.) vol IREI VIP1ARCHI.TECHNOLOGY, &1 115 METRO PHONE: LLC www.archi-technology.com PARK ROCHESTER, NY 14623 585.424.1952 Fax: 585.424.4239 r 0 O z J J W Z 0 U 1_, O Ct < >-- Z m ` J Q U CLIENT: (0 '® NETWORK pe 4 CONNECTIVITY Cornell University PROJECT ® i: tl ® °. CD 06/24 j I2 CONSTRUCTION DOCUMENTS 100 DD 05/31/12 100% DD SUBMISSION 50 DD 04/20/12 50% DD SUBMISSION 20 SD 10/14/11 20% SD SUBMISSION PSD 09/14/11 PRELIMINARY SD SUBMISSION MARK DATE DESCRIPTION CONSTRUCTION DOCUMENTS ISSUE DATE: 06/29/12 Y Mb. AT PROJECT NO: 11103-2010 OWNER PROJECT NO: 754 DRAWN BY: LP/EL/PKB CHECKED BY: JLB PROJECT MANAGER: GHS SHEET TITLE: DRAWING INDEX AND PROJECT SITE PLAN T -COVER Or L L a F- 0 a_ Cu Cu a, PLOT DATE BASEMENT 4B Scale: 1/32" = 0 16' 32' 64' 6;6 EXISTING MAIN SWITCHGEAR WITH GROUND BUS 3BO0438 II - E 0 3BOOUA EXISTING PANEL EMPP tr.11,0 11011 BASEMENT 3B — AMEP AREAS OF WORK Scale: 1/32" = 1'-0" 0 16' 32' 64' CONDUIT ROUTE FOR FEEDER TO MTR-2BA BASEMENT 2B — AMEP AREAS OF WORK Scale: 1/32" = 11-0" J: \PROJECTS -Ithaca \ 2011\11103 CORNELL - NCP\Uris Library 2010\ CAD \11103-2010--Tl-Slelwg SCALES ON THIS DRAWING ACCURATE WHEN PLOTTED TO 1 ARCH El (30X42 TN) 0 16' 32' 64' 666 BASEMENT Scale: 1/32" = 0 16' 32' 64' 666 r Wal FQP1ARCHI-TECHNOLOGY, IIIWIi‘ 115 METRO PHONE: LLC www.archi-technology.corn PARK ROCHESTER, NY 14623 585.424.1952 Fax: 585.424.4239 CD 1-1 C) N 1 >-- ce ce z (1) Ct LLI Z _1 LLI Z 0 co _I U < 1-1 CC i CLIENT: 1" Y44 4 NETWORK ip . k ) ll CorneUniversity PROJECT IEDA.$ CONNECTIVITY CD 06/29/12 CONSTRUCTION DOCUMLN i S 100 DD 05/31/12 100% DD SUBMISSION 50 DD 50% DD SUBMISSION 20 SD 20% SD SUBMISSION PSD 08/15/11PRELIMINARY SD SUBMISSION MARK DATE DESCRIPTION CONSTRUCTION DOCUMENTS ISSUE DATE: 06/29/12 rIsP010 42- clb,0 %*itiOilfr: ..c..,0F NEwk N. c0 0 _ ',.; 41 Jl 063163 WV' AT PROJECT NO: 11103-2010 OWNER PROJECT NO: 754 DRAWN BY: LP/EL/PKB CHECKED BY: JLB PROJECT MANAGER: GHS SHEET AMEP TITLE: AREAS OF WORK Ti-AMEP PROVIDE ESCUTCHEON PLATES AT ALL PIPE PENETRATIONS EXPOSED TO VIEW. SIZE ESCUTCHEON AROUND INSULATION ON INSULATED PIPE AND AROUND PIPE ON UNISULATED PIPES 61111111 NON -FIRE RATED WALL SLEEVE WHERE REQUIRED BY SPECIFICATIONS PIPE PIPE INSULATION - RUN INSULATION CONTINUOUS THROUGH WALL OPENING. kh..•11%, -14 h6.1% 111 v Fordwr.astil PROVIDE 1" CLEARANCE ALL AROUND NON FIRE RATED WALL PIPE PENETRATION Scale: NONE PROVIDE ESCUTCHEON PLATES AT ALL PIPE PENETRATIONS EXPOSED TO VIEW. SIZE ESCUTCHEON AROUND INSULATION ON INSULATED PIPE AND AROUND PIPE ON UNISULATED PIPES PIPE FIRE RATED WALL SLEEVE WHERE REQUIRED BY SPECIFICATIONS -41747.'Llowneta PIPE INSULATION - BUTT TIGHT TO FIRESTOPPING SYSTEM PROVIDE FIRESTOPPINO SYSTEM PER SPECIFICATIONS FIRE RATED WALL PIPE PENETRATION Scale: NONE - V ' v A CONCRETE DECK EXPANSION SHIELDS CONCRETE ANCHORS NOTE: REFER TO SPECIFICATION FOR REQUIRED ANCHOR CONFIGURATION. WASHER (TYPICAL) EXPANSION NAILS 0 CONCRETE ANCHOR DEVICE DETAIL Scale: NONE r 128001 12804 FCU -1 3/4" CONDENSATE AC -1 (ETR) 0 FLOOR DRAIN (ETR) 3/4" CONDENSATE DN TO EX. FLOOR DRAIN. ROUTE CONDENSATE TO AVOID OBSTRUCTING AC -1 ACCESS SECTIONS. 2BOOUA 3/4" CONDENSATE. PROVIDE CLEANOUTS AT ELBOWS. 2800U8 2800E8 2BOOCC1 BASEMENT 2B - MECHANICAL - NEW WORK Scale: 1/4" = 0 2' 8' PROVIDE INSULATION SHIELD & INSERT FOR ALL PIPING BAND HANGER RODS SIDE VIEW TRAPEZE HANGER INSULATION SHIELD AT HANGER PROVIDE HIGH COMPRESSIVE STRENGTH INSUL INSERT BETWEEN PIPE & INSULATION SHIELD ADJUSTABLE CLEVIS HANGER CHANNEL OR ANGLE HANGER ROD INSULATION WELD SADDLE ADJUSTABLE ROLLER HANGER NOTE: REFER TO PROJECT SPECIFICATION FOR ROD DIAMETER, END CONDITION (CLAMP, ANCHOR, ETC.) HANGER TYPES, AND CONFIGURATION. PIPE HANGER Scale: NONE ISOLATION VALVE (TYPICAL) FLOW BALANCING VALVE COIL MANUAL AIR VENT MV AIR FLOW PETE'S PLUGS (TYPICAL) THERMOMETER (TYPICAL) DRAIN W/HOSE END \--CONTROL VALVE UNION/FLANGE (TYPICAL) STRAINER NOTES: 1. PIPING TO ALLOW REMOVAL OF COIL WITH OUT REMOVING PIPING BEYOND UNIONS OR FLANGES. 2. FOR UNITS WITH MORE THAN ONE SECTION, PROVIDE FLOW BALANCER, UNIONS/ FLANGES, FLEXIBLE CONNECTORS, DRAINS AND AIR VENTS FOR EACH COIL. TWO-WAY CONTROL VALVE COIL PIPING DETAIL Scale: NONE GENERAL NOTES 1. REFER TO DRAWING T1-AMEP. COOLING COIL z -DRAIN SEE PLANS FOR CONTINUATION 11111111 NOTE: L =INCH (MINIMUM) H =INCH PLUS THE TOTAL UNIT STATIC PRESSURE AT WORST CASE (LOADED FILTERS) UNDER POSITIVE PRESSURE --COOLING COIL 77Z7 DRAIN SEE PLANS FOR CONTINUATION 7 CONNECT TO EXISTING COOLING COIL CONDENSATE DRAIN NOTE: L = H + J + P$PE DIAMETER H = 1 INCH FOR EACH INCH OF NEGATIVE PRESSURE* + 1 INCH J = H CONNECT TO EXISTING COOLING COIL CONDENSATE DRAIN * NEGATIVE PRESSURE = TOTAL UNIT STATIC PRESSURE AT WORST CASE (LOADED FILTERS) MINUS EXTERNAL PRESSURE UNDER NEGATIVE PRESSURE TYPICAL COOLING COIL DRAIN Scale: NONE UNIT LOCATION AIRFLOW ELECTRICAL CHILLED WATER COIL Architecture, Engineering, Lantiscape Architecture, P.C. Ph 315.472_4980 5789 Widewaters Parkway Fax 315.472.3523 Dewitt, New York 13214 E-mail Bakelleartisley.cont MOTOR (WATTS) V PH FLA EDB EWB LDB LWB TOTAL MBH SENSIBLE MBH EWT LWT GPM FLUID PD MANUF/MAKE NOTES FCU -1 MTR-2BA 420 62 115 1 1.2 75 63 55 54 11 9 52 62 1.8 4.0 EMI WCP-15 1,2,3,4 CONSTRUCTION DOCUMENTS 100 DD 05/31/12 100% DD SUBMISSION 50 DD 50% DD SUBMISSION 20 SD 20% SD SUBMISSION PSD 08/15/11 PRELIMINARY SD SUBMISSION MARK DATE DESCRIPTION CONSTRUCTION DOCUMENTS ISSUE DATE: 06/29/12 N. c(/ <k• r, •iii."'- `," 44 A-„ 44b,,0 63153 .C:r NOTES: 1. PROVIDE UNIT MOUNTED CONTROLS. 2. PROVIDE WASHABLE FILTER. 3. PROVIDE CONDENSATE PUMP. 4. EWT = 52' DURING WINTER MONTHS. EWT = 47DURING SUMMER MONTHS. NEW CHILLED WATER FAN COIL UNIT SCHEDULE Scale: NONE I J:\PROJECTS-Ithaca\2011\11103 CORNELL - NCP\Uris Library 2010\CAD\11103-2010--AMEP.dwa SCALES ON THIS DRAWING ACCURATE WHEN PLOI ILD TO: ARCH El (30X42 IN.) 1 ArowriMmi 01IM moin 115 METRO PHONE: ARCHI-TECHNOLOGY, LLC www.archi-technology.com PARK ROCHESTER, NY 14623 585.424.1952 Fax: 585.424.4239 WOBEARDSLEY DESIGN ASSOCIATES Architecture, Engineering, Lantiscape Architecture, P.C. Ph 315.472_4980 5789 Widewaters Parkway Fax 315.472.3523 Dewitt, New York 13214 E-mail Bakelleartisley.cont TI CD N 1 ce ri: Z in Ct LLI z LLI Z CL 0 U _I U Cf) < 1 F— D II CLIENT: a I° NETWORK . Cornell University CONNECTIVITY PROJECT 0- 1144:e 11111 - ... CD 9/12 CONSTRUCTION DOCUMENTS 100 DD 05/31/12 100% DD SUBMISSION 50 DD 50% DD SUBMISSION 20 SD 20% SD SUBMISSION PSD 08/15/11 PRELIMINARY SD SUBMISSION MARK DATE DESCRIPTION CONSTRUCTION DOCUMENTS ISSUE DATE: 06/29/12 N. c(/ <k• r, •iii."'- `," 44 A-„ 44b,,0 63153 .C:r AT PROJECT NO: 11103-2010 OWNER PROJECT NO: 754 DRAWN BY: LP/EL/PKB CHECKED BY: JLB PROJECT MANAGER: GHS SHEET TITLE: MECHANICAL DETAILS M4 O 0 CO PLOT DATE: dune PANL3OAR SC DU _E NOTES: SE RATED fj HINGED TRIM ❑ COMPUTER GRADE ❑ 200% NEUTRAL FEED-THRU LUGS SUB FEED LUGS SUB -FEED BREAKER p] ISOLATED GND BUS NAME LOCATION SOURCE RATING (AMPS) CP TR2BA MTR-2BA MCB MLO PH/WIRE VOLTAGE MOUNTING KAIC DESIGN MAKE NEMA TYPE 60A 3/4 120/208 SURFACE 10 CKT NO DESCRIPTION UPS RECEPTACLE Ell 15 SPARE m 19 21 23 SPARE SPARE SPARE SPARE BREAKER 20/1 20/1 SPARE SPARE 20/1 PH. A 1.8 20/1 SPARE SPARE SPARE 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 KVA LOAD PH. B 0.1 PH. C FIFTH FLOOR FOURTH FLOOR THIRD FLOOR SECOND FLOOR FIRST FLOOR BASEMENT BASEMENT 2B BASEMENT 3B BASEMENT 4B BASEMENT 5B KVA LOAD PH. A 1.8 PH. B PH. C BREAKER 20/1 DESCRIPTION UPS RECEPTACLE CKT UO 2 20/1 SPARE 4 20/1 SPARE 6 20/1 SPARE 8 20/1 SPARE 10 20/1 SPARE 12 20/1 SPARE 14 20/1 SPARE 16 20/1 SPARE 18 20/1 SPARE 20 20/1 SPARE 22 20/1 SPARE 24 ELECTRICAL PANELBOARD SCHEDULES Scale: NONE POWER & GROUNDING SYSTEM RISER DIAGRAM Scale: NONE FIXTURE LAMPS REMARKS TYPE DESCRIPTION VOLTS PROVIDE 60A 3P BREAKER QTY. WATTS LAMP CODE 3/0 AWG IN 3/4" CONDUIT 4 FT. SURFACE FLUORESCENT WITH HIGH IMPACT ACRYLIC LENS AND ELECTRONIC BALLAST 120/277 2Es04 WITH M BREAKER AIN I I 32 F032T8f835 MTR-2BA (Rivi. 6 {{ 6 AWG AWG ( PACPEL TR2BA•r 2 FT. SURFACE FLUORESCENT WITH HIGH IMPACT ACRYLIC LENS AND ELECTRONIC BALLAST TMGB f STEEL LITHONIA LB-217—MVOLT—GEB101 S 2 17 F017T8/835 ELECTRIC I ROOM 3BOOUA I 1 _ ! EX. TWIN HEAD EMERGENCY LIGHTING UNIT 'r (4) #6 AWG WITH (1) #8 AWG GROUND IN 1" CONDUITEX 2 5 ( �^ NOTES: 1. FURNISH WITH <10% THD ELECTRONIC BALLAST. 2. FURNISH WITH HIGH IMPACT PRISMATIC DIFFUSER. 3. PROVIDE 24" PENDANT CD 06/29/12 GROUND 100 DD 05/31/12 PANEL EMPP MAIN SWITCHGEAR 50% DD SUBMISSION 20 SD POWER & GROUNDING SYSTEM RISER DIAGRAM Scale: NONE FIXTURE LAMPS REMARKS TYPE DESCRIPTION VOLTS MANUFACTURER & CATALOG NUMBER QTY. WATTS LAMP CODE FA 4 FT. SURFACE FLUORESCENT WITH HIGH IMPACT ACRYLIC LENS AND ELECTRONIC BALLAST 120/277 LITHONIA CLM-232—MVOLT—GEB 2 32 F032T8f835 1,2,3 FB 2 FT. SURFACE FLUORESCENT WITH HIGH IMPACT ACRYLIC LENS AND ELECTRONIC BALLAST 120/277 LITHONIA LB-217—MVOLT—GEB101 S 2 17 F017T8/835 1,2 EM TWIN HEAD EMERGENCY LIGHTING UNIT 120/277 CFX6McPHILBEN 2 5 HALOGEN NOTES: 1. FURNISH WITH <10% THD ELECTRONIC BALLAST. 2. FURNISH WITH HIGH IMPACT PRISMATIC DIFFUSER. 3. PROVIDE 24" PENDANT LIGHTING FIXTURE SCHEDULE Scale: NONE FIFTH FLOOR FOURTH FLOOR THIRD FLOOR SECOND FLOOR FIRST FLOOR BASEMENT BASEMENT 2B BASEMENT 3B BASEMENT 4B BASEMENT 5B GENERAL NOTES 1. REFER TO DRAWING T1—AMEP. TMGB OR TGB LABEL PROVIDE ENGRAVED TAG FOR EACH GROUNDING CONDUCTOR, BOTH ENDS AND AT EXPOSED PASS THROUGH MECHANICAL SPACES AND AT ENTRANCES/ EXITS TO SHAFTWAYS, TYPICAL. O DIV. 26 CONTRACTOR TO PROVIDE INSULATED TIN PLATED TELECOM SYSTEM GROUND BUS BAR. HOLE CENTERS TO MATCH LUG CONFIGURATION AND EIA/TIA 607 STANDARDS. REFER TO SECTIONS 260526 and 271100. 0 0 0 0 TMGB — ERICO/ERITECH # TMGB—A20L27PT TGB — ERICO/ERITECH # TGB—A20L12PT INSULATORS. 5/8" LOCKWASHERS. WALL MOUNTING BRACKET. 5/8-11X1" H.H.C.S. BOLTS. DIV. 26 CONTRACTOR TO PROVIDE LONG BARREL COMPRESSION LUG, TWO BOLT, COMPRESSION LUG (BURNDY HYLUG YAZ SERIES) OR EQUAL. PROVIDE A MINIMUM OF EIGHT (8) SPARE LUGS WITH 5/16" HOLES FOR FUTURE USE BY OWNER. DRILL AND TAP AS REQUIRED. SCRUFF BAR AND PROVIDE ANTIOXIDANT AS CALLED FOR. REFER TO SECTIONS 260526 and 771100. TELECOMMUNICATIONS GROUND BAR (TMGB, TGB) DETAIL 0 Scale: NONE TEMPORARILY REMOVE EX. 4 FOOT FLUORESCENT LIGHT FIXTURE TO FACILITATE INSTALLATION OF SOFFIT IN THIS AREA. RE—INSTALL FIXTURE ONTO SOFFIT FOLL•,,1 :G CONSTRUCTION OF SOFFIT. 48" VIE NEW SOFFIT - BASEMENT STAIRWELL BOOSA Scale: 1/4" = 1'-0" B 1 .09 J:\PROJECTS—Ithaca\2011\11103 CORNELL — NCP\Uris Library 2010\CAD\11103-2010--AMEP.dwq SCALES ON THIS DRAWING ACCURATE WHEN PLOTTED TO: ARCH El (30X42 IN.) flekrirn _IM Imill 115 METRO PHONE: ARCHIITECHNOLOGY, LLC www.archi-technology.com PARK ROCHESTER, NY 14623 585.424.1952 Fax: 585.424.4239 EARDSLEY DESIGN ASSOCIATES Architecture, Engineering, Landscape Architecture, P.C. Ph 315.472.648® 5789 Widewaters Parkway Fax 315.472.3523 Dewitt, New York 13214 E-mail 1$DAMBeardsley.eam >-- z Q Uce Q H I (.i) W z W CLIENT: u Xi o `Po Cornell University CONNECTIVITY PROJECT NETWORK G 1i10u erra CD 06/29/12 CONSTRUCTION DOCUMENTS 100 DD 05/31/12 100% DD SUBMISSION 50 DD 50% DD SUBMISSION 20 SD 20% SD SUBMISSION PSD 08/15/11 PRELIMINARY SD SUBMISSION MARK DATE DESCRIPTION CONSTRUCTION DOCUMENTS ISSUE DATE: 06/29/12 tz- .�©F NEW y Ni- 663153 <r� A9Fa. SIONP AT PROJECT NO: 11103-2010 OWNER PROJECT NO: 754 DRAWN BY: LP/EL/PKB CHECKED BY: JLB PROJECT MANAGER: GHS SHEET TITLE: ELECTRICAL DETAILS E4 GENERAL NOTES FOR ALL TRADES: REFER TO DRAWING "T -GEN" FOR PROJECT NOTES AND ABBREVIATIONS APPLICABLE TO ALL DRAWINGS AND CONTRACTS. REFER TO TABLES ON THIS PAGE FOR DRAWING SYMBOLS AND ABBREVIATIONS PER TRADE. REFER TO AMEP-xx DRAWINGS FOR GENERAL NOTES AND KEYED NOTES SPECIFIC TO TRADE. THIS INFORMATION REPRESENTS EXISTING CONDITIONS BASED ON ORIGINAL DRAWINGS AND OBSERVED SITE CONDITIONS. NOT ALL ELECTRICAL/MECHANICAL EQUIPMENT IS SHOWN. THE CONTRACTOR SHALL FIELD VERIFY EXACT ROUTING, DIMENSIONS AND QUANTITIES. REFER TO MECHANICAL, ELECTRICAL AND COMMUNICATION DRAWINGS FOR ADDITIONAL DEMOLITION AND RENOVATION WITHIN THE INDICATED WORK AREAS. REFER TO T2-x.CA_CP DRAWINGS FOR CEILING ACCESS PANEL LOCATIONS. REFER TO DRAWING T3-xx DRAWINGS FOR ADDITIONAL COORDINATION REQUIREMENTS. GENERAL CONSTRUCTION CONTRACTOR SHALL PERFORM ALL WORK AS SHOWN ON AMEP DRAWINGS, UNLESS NOTED OTHERWISE. REFER TO SPECIFICATIONS 011x00 FOR ADDITIONAL INFORMATION. REFER TO THE PROJECT MANUAL/TECHNICAL SPECIFICATION SECTIONS FOR ADDITIONAL PRODUCT AND/OR EXECUTION REQUIREMENTS TO SUPPLEMENT INFORMATION CONTAINED ON THE DRAWINGS. CUTTING AND PATCHING OF OPENINGS IN EXISTING BUILDING CONSTRUCTION SHALL BE DONE IN A MANNER WHICH DOES NOT IMPAIR THE STRUCTURAL INTEGRITY OF THE CONSTRUCTION AND MAINTAINS ALL REQUIRED FIRE RATINGS. PATCHING SHALL INCLUDE ALL OPENINGS LEFT IN EXISTING CONSTRUCTION DUE TO DEMOLITION WORK. ALL PATCHED SURFACES ARE TO BE RESTORED AS CLOSELY AS POSSIBLE TO THE ORIGINAL CONDITIONS. ALL PATCHED AREAS REQUIRING PAINT SHALL RECEIVE TWO PRIMER COATS AND TWO FINISH COATS. MATERIALS USED FOR PATCHING SHALL MATCH EXISTING ADJACENT MATERIALS IN BOTH TYPE AND QUALITY. NEW ELECTRICAL AND MECHANICAL SYSTEMS WHICH PENETRATE NEW AND EXISTING FIRE RATED FLOORS, WALLS AND OTHER ASSEMBLIES SHALL BE FIRESTOPPED. IN AREAS ACCESSIBLE TO THE PUBLIC, FIRESTOP SYSTEMS SHALL BE SELECTED, INSTALLED AND FINISHED TO THE QUALITY OF ADJACENT SURFACES OF BUILDING CONSTRUCTION BEING PENETRATED. REFER TO SPECIFICATION 078413 FOR ADDITIONAL INFORMATION. ALL PLAN DIMENSIONS ARE TO FACE OF PARTITION ASSEMBLY OR FINISH SURFACE (EXCLUDING PLYWOOD BACKBOARDS). CONTRACTOR IS TO VERIFY ALL DRAWING DIMENSIONS IN THE FIELD FOR ACCURACY. M. PROVIDE SOFT COPY SUBMITTAL(S) ON ACTUAL PRODUCTS USED. INCLUDE COPY OF APPROVED SUBMITTAL WITH CLOSE OUT DOCUMENTS (IN HARD COPY 0/M MANUAL), REFER TO SECTIONS: 013300 - SUBMITTALS; 017839 - RECORD DOCUMENTS; AND 017700 - PROJECT CLOSEOUT AS APPLICABLE. N ANY DRILLING, CUTTING ETC. WORK THAT MAY CREATE A NUISANCE FIRE ALARM, NEEDS TO BE SCHEDULED 24 HOURS IN ADVANCE WITH CUSTOMER SERVICE FOR A FIRE PROTECTION SYSTEM SHUTDOWN. SHUTDOWN WILL BE PERFORMED BY EH&S (ENVIRONMENTAL HEALTH AND SAFETY) STAFF. CONTRACTOR WILL NOT DISABLE ANY FIRE PROTECTION EQUIPMENT WITHOUT EH&S APPROVAL/ASSISTANCE. 0. ALL NEW SMOKE DETECTORS AND OTHER FIRE ALARM INITIATION/NOTIFICATION DEVICES WILL NEED TO BE TESTED BY EH&S AND AHJ (AUTHORITY HAVING JURISDICTION) FOR PROPER OPERATION OF DEVICE, DAMPER AND EXHAUST FAN SHUTDOWN. ARCHITECTURAL GENERAL NOTES: A. CLEAN ALL ROOMS DUST FREE FOLLOWING COMPLETION OF DEMOLITION AND PATCHING WORK. B. PROVIDE FIRESTOPPING IN ACCORDANCE WITH SPECIFICATION SECTION 078413 WHERE ITEMS (INCLUDING CABLE TRAYS, PIPES, CONDUIT, FRAMING MEMBERS AND DUCTS) PENETRATE BOTH NEW AND EXISTING FIRE RATED PARTITIONS. FIRE RATED PARTITIONS ARE INDICATED ON ARCHITECTURAL DRAWINGS. FOR SMOKE, FIRE, OR FIRE/SMOKE DAMPERS, TREAT PENETRATION IN ACCORDANCE WITH DAMPER MANUFACTURER'S PRINTED DIRECTIONS. USE OF FIRESTOPPING WILL INVALIDATE UL LISTING OF DAMPER. C. SEAL PENETRATIONS OF BOTH NEW AND EXISTING NON -RATED PARTITIONS INCLUDING CABLE TRAYS, PIPES, CONDUIT, FRAMING MEMBERS AND DUCTS. PROVIDE ELASTOMERIC SEALANT AT GYPSUM WALLBOARD PARTITIONS. PROVIDE MORTAR/GROUT FOR PIPES AND CONDUIT THROUGH MASONRY PARTITIONS. PROVIDE ELASTOMERIC SEALANT AT EXTERIOR WALLS. ARCHITECTURAL SYMBOLS LEGEND Scale: NONE HVAC GENERAL NOTES: A. VERIFY ALL EXISTING CONDITIONS. EQUIPMENT LOCATIONS SHOWN ARE APPROXIMATE AND MINOR ADJUSTMENTS TO THE INSTALLATION MAY BE REQUIRED TO AVOID CONFLICTS WITH EXISTING EQUIPMENT AND APPARATUS - EXISTING BRANCH CIRCUITS ARE FROM RECORD DRAWINGS, AND MAY VARY. B. FIELD VERIFY ALL EXISTING CONDITIONS AND DETERMINE THE BEST PATH FOR NEW INSTALLATIONS THAT WILL CAUSE THE LEAST DISTURBANCE TO OCCUPIED SURROUNDINGS. PATHWAYS THAT ARE ROUTED THROUGH MECHANICAL ROOMS, UTILITY ROOMS, STORAGE CLOSETS, ETC. ARE FAVORABLE TO DISTURBANCES IN OCCUPIED AREAS. C. INSTALL ALL EQUIPMENT IN STRICT CONFORMANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS AND RECOMMENDATIONS. D. COORDINATE THE WORK SHOWN ON THESE DRAWINGS WITH THE WORK OF ALL OTHER TRADES PRIOR TO THE FABRICATION OR INSTALLATION OF ANY WORK. EQUIPMENT AND DEVICES THAT CANNOT CHANGE LOCATION SHALL TAKE PRECEDENCE OVER THOSE THAT CAN CHANGE. E. THESE DRAWINGS ARE SCHEMATIC IN NATURE. PROVIDE ALL OFFSETS, HANGERS, ANCHORS, SUPPORTS, WIRING AND ACCESSORIES FOR A COMPLETE, OPERATIONAL INSTALLATION. F. WHERE CEILINGS ARE REMOVED TO ACCOMMODATE NEW TELECOM ROOMS, PROVIDE SUPPORT(S) FOR ALL REMAINING MECHANICAL PIPING, DUCTWORK, MISCELLANEOUS EQUIPMENT, ETC. NOT BEING REMOVED. ALL UNUSED EQUIPMENT & APPURTENANCES SHALL BE REMOVED AND PROPERLY DISPOSED OF. G. ALL EXISTING AND NEW PIPING, DUCTWORK, MECHANICAL EQUIPMENT IN TELECOM ROOMS SHALL BE CLEANED FREE OF DUST/DEBRIS AFTER WALL DEMOLITION AND AFTER WALL RECONSTRUCTION/PATCHING. REMOVALS INDICATED AS DASHED LINES — AIR FLOW AC NEW WALL TYPE - REFER TO KEYED NOTES FOR CONSTRUCTION LIGHTING FIXTURE, WALL MOUNT 0 (--(1r ROOM NUMBER DUPLEX RECEPTACLE OUTLET, 20 AMPERE, VOLT, TOP OF BOX AT 24" AFF UNLESS OTHERWISE NOTED. WI -4 NEW TO EXISTING CONNECTION AHU EXISTING DOOR TO REMAIN DUCT - DOWN - POSITIVE PRESSURE EM LIGHTING FIXTURE t; 00 DOOR NUMBER (NEW OR EXISTING) © A NEW DOOR AND FRAME -. PP1/3 BRANCH CIRCUIT HOMERUN, SUBSCRIPT INDICATES PANELBOARD & CIRCUIT DESIGNATION, QUANTITY OF ARROWHEADS DENOTES QUANTITY OF BRANCH CIRCUITS. PROVIDE GREEN GROUND WIRE AND ONE NEUTRAL PER PHASE CONDUCTOR IN EACH CIRCUIT. PROTECT EACH CIRCUIT WITH A 20 AMPERE, 1–POLE OVERCURRENT DEVICE. UNLESS OTHERWISE INDICATED, MINIMUM WIRE SIZE SHALL BE #10 THHN. AMERICAN WIRE GAUGE MD INDICATES 2 -HOUR RATED FIRE SEPARATION immIlimiml i VENT INDICATES 1 -HOUR RATED FIRE SEPARATION immimi i FIRE ALARM SYSTEM SMOKE DETECTOR CEILING ACCESS PANEL POWER PANEL AP ATMOSPHERIC CHWS ARCHITECTURAL SYMBOLS LEGEND Scale: NONE HVAC GENERAL NOTES: A. VERIFY ALL EXISTING CONDITIONS. EQUIPMENT LOCATIONS SHOWN ARE APPROXIMATE AND MINOR ADJUSTMENTS TO THE INSTALLATION MAY BE REQUIRED TO AVOID CONFLICTS WITH EXISTING EQUIPMENT AND APPARATUS - EXISTING BRANCH CIRCUITS ARE FROM RECORD DRAWINGS, AND MAY VARY. B. FIELD VERIFY ALL EXISTING CONDITIONS AND DETERMINE THE BEST PATH FOR NEW INSTALLATIONS THAT WILL CAUSE THE LEAST DISTURBANCE TO OCCUPIED SURROUNDINGS. PATHWAYS THAT ARE ROUTED THROUGH MECHANICAL ROOMS, UTILITY ROOMS, STORAGE CLOSETS, ETC. ARE FAVORABLE TO DISTURBANCES IN OCCUPIED AREAS. C. INSTALL ALL EQUIPMENT IN STRICT CONFORMANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS AND RECOMMENDATIONS. D. COORDINATE THE WORK SHOWN ON THESE DRAWINGS WITH THE WORK OF ALL OTHER TRADES PRIOR TO THE FABRICATION OR INSTALLATION OF ANY WORK. EQUIPMENT AND DEVICES THAT CANNOT CHANGE LOCATION SHALL TAKE PRECEDENCE OVER THOSE THAT CAN CHANGE. E. THESE DRAWINGS ARE SCHEMATIC IN NATURE. PROVIDE ALL OFFSETS, HANGERS, ANCHORS, SUPPORTS, WIRING AND ACCESSORIES FOR A COMPLETE, OPERATIONAL INSTALLATION. F. WHERE CEILINGS ARE REMOVED TO ACCOMMODATE NEW TELECOM ROOMS, PROVIDE SUPPORT(S) FOR ALL REMAINING MECHANICAL PIPING, DUCTWORK, MISCELLANEOUS EQUIPMENT, ETC. NOT BEING REMOVED. ALL UNUSED EQUIPMENT & APPURTENANCES SHALL BE REMOVED AND PROPERLY DISPOSED OF. G. ALL EXISTING AND NEW PIPING, DUCTWORK, MECHANICAL EQUIPMENT IN TELECOM ROOMS SHALL BE CLEANED FREE OF DUST/DEBRIS AFTER WALL DEMOLITION AND AFTER WALL RECONSTRUCTION/PATCHING. ®MECHANICAL SYMBOLS LEGEND Scale: NONE ELECTRICAL GENERAL NOTES: A. VERIFY ALL EXISTING CONDITIONS. EQUIPMENT LOCATIONS SHOWN ARE APPROXIMATE AND MINOR ADJUSTMENTS TO THE INSTALLATION MAY BE REQUIRED TO AVOID CONFLICTS WITH EXISTING EQUIPMENT AND APPARATUS - EXISTING BRANCH CIRCUITS ARE FROM RECORD DRAWINGS, AND MAY VARY. B. FIELD VERIFY ALL EXISTING CONDITIONS AND SHALL DETERMINE THE BEST PATH FOR NEW INSTALLATIONS THAT WILL CAUSE THE LEAST DISTURBANCE TO OCCUPIED SURROUNDINGS. PATHWAYS THAT ARE ROUTED THROUGH MECHANICAL ROOMS, UTILITY ROOMS, STORAGE CLOSETS, ETC. ARE FAVORABLE TO DISTURBANCES IN OCCUPIED AREAS, ALL NEW LUMINAIRES SHALL BE INSTALLED AT A MINIMUM HEIGHT OF 9'-6" AFF UNLESS OTHERWISE NOTED. C. COORDINATE MOUNTING HEIGHT OF ALL NEW POWER OUTLETS WITH THE TELECOMMUNICATIONS SYSTEMS EQUIPMENT ELEVATION DRAWINGS/DETAILS. D. COORDINATE ALL REQUIRED POWER AND FIRE ALARM SHUTDOWNS WITH THE OWNER. PROVIDE MINIMUM 1 WEEK ADVANCE NOTICE. E. WHERE CEILINGS ARE REMOVED TO ACCOMMODATE NEW TELECOM ROOMS, PROVIDE SUPPORT(S) FOR ALL REMAINING ELECTRICAL CONDUITS, DEVICES, EQUIPMENT, ETC. NOT BEING REMOVED. ALL UNUSED EQUIPMENT SHALL BE REMOVED AND PROPERLY DISPOSED OF. F. ALL EXISTING AND NEW CONDUIT AND ELECTRICAL EQUIPMENT IN TELECOM ROOMS SHALL BE CLEANED FREE OF DUST/DEBRIS AFTER WALL DEMOLITION AND AFTER WALL RECONSTRUCTION/ PATCHING. G. PROVIDE GROUNDING IDENTIFICATION AS CALLED FOR. PROVIDE TAGS ON GROUND CONDUCTOR. IN ALL SPACES AS DIRECTED AND SHOWN ON GROUNDING DETAIL. H. DURING CONSTRUCTION, PROVIDE HEAT DETECTORS IN TELECOM ROOMS. AT SUBSTANTIAL COMPLETION AND AFTER FINAL CLEANING, CHANGE HEAT DETECTOR TO SMOKE DETECTOR. I. ALL FIRE ALARM SYSTEM DEVICES SHALL BE TESTED BY EH&S AND AHJ FOR PROPER OPERATION OF DETECTOR, DAMPER, AND FAN SHUTDOWN. o a O DUCT - UP - NEGATIVE PRESSURE (E) AIR FLOW AC PIPING SYMBOLS LIGHTING FIXTURE, WALL MOUNT 0 (--(1r (P)120 DUPLEX RECEPTACLE OUTLET, 20 AMPERE, VOLT, TOP OF BOX AT 24" AFF UNLESS OTHERWISE NOTED. ABOVE FINISH FLOOR -4 NEW TO EXISTING CONNECTION AHU DOUBLE DUPLEX RECEPTACLE OUTLET, 20 AMPERE, 120 VOLT, TOP OF BOX AT 24" AFF UNLESS OTHERWISE NOTED. DUCT - DOWN - POSITIVE PRESSURE EM LIGHTING FIXTURE APD ON © A AIR -. PP1/3 BRANCH CIRCUIT HOMERUN, SUBSCRIPT INDICATES PANELBOARD & CIRCUIT DESIGNATION, QUANTITY OF ARROWHEADS DENOTES QUANTITY OF BRANCH CIRCUITS. PROVIDE GREEN GROUND WIRE AND ONE NEUTRAL PER PHASE CONDUCTOR IN EACH CIRCUIT. PROTECT EACH CIRCUIT WITH A 20 AMPERE, 1–POLE OVERCURRENT DEVICE. UNLESS OTHERWISE INDICATED, MINIMUM WIRE SIZE SHALL BE #10 THHN. AMERICAN WIRE GAUGE MD DUCT - DOWN - NEGATIVE PRESSUREATV IBJ VENT Cl CAPPED DUCT i FIRE ALARM SYSTEM SMOKE DETECTOR CONC POWER PANEL HD ATMOSPHERIC CHWS PANEL CHWR CHILLED WATER RETURN CHWS&R TELECOMMUNICATIONS GROUNDING BUS BAR DUCT - UP THRU ROOF - NEGATIVE PRESSURE CARD READER LOCK db TGB CA COMPRESSED AIR CRL DOWN DUCT TRANSITION FROM RECTANGULAR TO ROUND DRAWING DRAIN EXHAUST AIR EAT DUCT - UP THRU ROOF - POSITIVE PRESSURE ��I'' 'll" H �; CD CONDENSATE EF EXHAUST FAN EH&S RETURN ® i DUCT - UP -POSITIVE PRESSURE EMERGENCY EMS DUCT TRANSITION FROM RECTANGULAR TO RECTANGULAR CHWR CHILLED WATER ERM CHILLED WATER SUPPLY & RETURN ESP DUAL INPUT READER INTERFACE MODULE DUCT SIZE - FIRST FIGURE IS SIZE SHOWN CHWS&R EWB MEM EWT ENTERING WATER TEMPERATURE (F) CHILLED WATER SUPPLY ]- EXP SQUARE THROAT RADIUS ELBOW •F DC CHWS FIRE ALARM FACP FIRE ALARM CONTROL PANEL FLEXIBLE CONNECTION FAN COIL UNIT DOMESTIC COLD WATER FIRE DAMPER FLA FULL LOAD AMPS FPM DCW FSD COMBINATION FIRE/SMOKE DAMPER FT OR ' DHR DOMESTIC HOT WATER RETURN GENERAL CONSTRUCTION CONTRACTOR GPM GALLONS PER MINUTE ACOUSTICALLY LINED DUCTWORK GYPSUM BOARD HM HOLLOW METAL SQUARE TO ROUND BRANCH DUCT HORSEPOWER HVAC ii HWR HOT WATER RETURN DOMESTIC HOT WATER HOT WATER SUPPLY HWS&R HOT WATER SUPPLY & RETURN IP INTERIOR PAINT DHW JUNCTION BOX KD KNOCK -DOWN FRAME FLEXIBLE DUCT KILOWATTS LAT LEAVING AIR TEMPERATURE (F) LDB NATURAL GAS LWB DINO. LWT G MAX MAXIMUM HOT WATER RETURN -ThT"--1HWS MCA VOLUME DAMPER HWR MAIN CIRCUIT BREAKER MDP MAIN DISTRIBUTION PANEL DUCT WYE MINIMUM NC NORMALLY CLOSED HOT WATER SUPPLY NORMALLY OPEN PD RECTANGULAR ELBOW WITH TURNING VANES PF SPRINKLER PIPING N_) i OR PLAS PLASTER SP POUNDS PER SQUARE INCH PT 0 PIPING RISE PLYWOOD RA RETURN AIR RB RUBBER BASE/SILL rRADIUS RETURN FAN ELBOW (MIN R/W = 1.5) REFRIGERANT LIQUID PIPING DROP REFRIGERANT SUCTION RRT t 0 SUPPLY AIR Os DIGITAL SENSOR I CAPPED PIPE ST CEILING GRILLE (G) REGISTER (R) TGB TELECOMMUNICATIONS GROUNDING BUSBAR TMGB TELECOMMUNICATIONS MAIN GROUNDING BUSBAR TYP TYPICAL V ® THERMOSTAT VARIABLE AIR VOLUME DIRECTION OF FLUID FLOW VINYL BASE VCT PITCH PIPING DOWN VD CEILING DIFFUSER (D) OG THERMOSTAT OR SENSOR WITH GUARD VEL VELOCITY WD DN WMP 6- SHUT OFF VALVE O SPRINKLER HEAD (CEILING) ' DOOR LOUVER OR UNDERCUT • SPRINKLER HEAD (ABOVE CEILING) L POINT OF DISCONNECT R DUCT RISE IN ELEVATION > D DUCT DROP IN ELEVATION ®MECHANICAL SYMBOLS LEGEND Scale: NONE ELECTRICAL GENERAL NOTES: A. VERIFY ALL EXISTING CONDITIONS. EQUIPMENT LOCATIONS SHOWN ARE APPROXIMATE AND MINOR ADJUSTMENTS TO THE INSTALLATION MAY BE REQUIRED TO AVOID CONFLICTS WITH EXISTING EQUIPMENT AND APPARATUS - EXISTING BRANCH CIRCUITS ARE FROM RECORD DRAWINGS, AND MAY VARY. B. FIELD VERIFY ALL EXISTING CONDITIONS AND SHALL DETERMINE THE BEST PATH FOR NEW INSTALLATIONS THAT WILL CAUSE THE LEAST DISTURBANCE TO OCCUPIED SURROUNDINGS. PATHWAYS THAT ARE ROUTED THROUGH MECHANICAL ROOMS, UTILITY ROOMS, STORAGE CLOSETS, ETC. ARE FAVORABLE TO DISTURBANCES IN OCCUPIED AREAS, ALL NEW LUMINAIRES SHALL BE INSTALLED AT A MINIMUM HEIGHT OF 9'-6" AFF UNLESS OTHERWISE NOTED. C. COORDINATE MOUNTING HEIGHT OF ALL NEW POWER OUTLETS WITH THE TELECOMMUNICATIONS SYSTEMS EQUIPMENT ELEVATION DRAWINGS/DETAILS. D. COORDINATE ALL REQUIRED POWER AND FIRE ALARM SHUTDOWNS WITH THE OWNER. PROVIDE MINIMUM 1 WEEK ADVANCE NOTICE. E. WHERE CEILINGS ARE REMOVED TO ACCOMMODATE NEW TELECOM ROOMS, PROVIDE SUPPORT(S) FOR ALL REMAINING ELECTRICAL CONDUITS, DEVICES, EQUIPMENT, ETC. NOT BEING REMOVED. ALL UNUSED EQUIPMENT SHALL BE REMOVED AND PROPERLY DISPOSED OF. F. ALL EXISTING AND NEW CONDUIT AND ELECTRICAL EQUIPMENT IN TELECOM ROOMS SHALL BE CLEANED FREE OF DUST/DEBRIS AFTER WALL DEMOLITION AND AFTER WALL RECONSTRUCTION/ PATCHING. G. PROVIDE GROUNDING IDENTIFICATION AS CALLED FOR. PROVIDE TAGS ON GROUND CONDUCTOR. IN ALL SPACES AS DIRECTED AND SHOWN ON GROUNDING DETAIL. H. DURING CONSTRUCTION, PROVIDE HEAT DETECTORS IN TELECOM ROOMS. AT SUBSTANTIAL COMPLETION AND AFTER FINAL CLEANING, CHANGE HEAT DETECTOR TO SMOKE DETECTOR. I. ALL FIRE ALARM SYSTEM DEVICES SHALL BE TESTED BY EH&S AND AHJ FOR PROPER OPERATION OF DETECTOR, DAMPER, AND FAN SHUTDOWN. o a O LIGHTING FIXTURE, CEILING MOUNTED (E) SINGLE RECEPTACLE OUTLET, 20 AMPERE DEDICATED U.P.S. CIRCUIT, 120 VOLT, TOP OF BOX AT 24" AFF SURFACE MOUNTED ON PLYWOOD UNLESS OTHERWISE NOTED. AC AIR CONDITIONING LIGHTING FIXTURE, WALL MOUNT I Q 9 AD (P)120 DUPLEX RECEPTACLE OUTLET, 20 AMPERE, VOLT, TOP OF BOX AT 24" AFF UNLESS OTHERWISE NOTED. ABOVE FINISH FLOOR LIGHTING FIXTURE, FLUORESCENT, CEILING MOUNTED, INDUSTRIAL/STRIP "•' AHU DOUBLE DUPLEX RECEPTACLE OUTLET, 20 AMPERE, 120 VOLT, TOP OF BOX AT 24" AFF UNLESS OTHERWISE NOTED. ©©� EM LIGHTING FIXTURE APD AIR PRESSURE DROP " WG APPROX APPROXIMATELY 20 AMPERE, 277 VOLT, SINGLE POLE AC SWITCH, TOP OF BOX AT 48" AFF DEFINITION OF SUBSCRIPTS: 2 TWO POLE SWITCH 3 THREE WAY SWITCH 4 FOUR WAY SWITCH M FRACTIONAL HORSEPOWER, MANUAL MOTOR STARTER W/ THERMAL OVERLOADS abc LOWER CASE LETTER(S) SIGNIFY SWITCHING DESIGNATIONS, QUANTITY OF LETTERS EQUALS QUANTITY OF GANGED SWITCHES. -. PP1/3 BRANCH CIRCUIT HOMERUN, SUBSCRIPT INDICATES PANELBOARD & CIRCUIT DESIGNATION, QUANTITY OF ARROWHEADS DENOTES QUANTITY OF BRANCH CIRCUITS. PROVIDE GREEN GROUND WIRE AND ONE NEUTRAL PER PHASE CONDUCTOR IN EACH CIRCUIT. PROTECT EACH CIRCUIT WITH A 20 AMPERE, 1–POLE OVERCURRENT DEVICE. UNLESS OTHERWISE INDICATED, MINIMUM WIRE SIZE SHALL BE #10 THHN. AMERICAN WIRE GAUGE MD MOTION DETECTOR, WALL SWITCH TYPE IBJ JUNCTION BOX, SURFACE MOUNT Cl DISCONNECT SWITCH OS FIRE ALARM SYSTEM SMOKE DETECTOR CONC POWER PANEL HD FIRE ALARM SYSTEM HEAT DETECTOR CHWS PANEL CHWR CHILLED WATER RETURN CHWS&R TELECOMMUNICATIONS GROUNDING BUS BAR CRL CARD READER LOCK db TGB DIA, 0 DIAMETER CRL DOWN DWG DRAWING EA EXHAUST AIR EAT TELECOMMUNICATIONS MAIN GROUNDING BUS BAR EDB ENTERING DRY BULB EER SINGLE INPUT READER INTERFACE MODULE EF EXHAUST FAN EH&S ENVIRONMENTAL HEALTH Sc SAFETY TMGB EFFICIENCY EM EMERGENCY EMS ENERGY MANAGEMENT SYSTEM ERL - ERM EXISTING TO BE REMOVED ESP DUAL INPUT READER INTERFACE MODULE ETR DRI EWB ENTERING WET BULB (F) EWT ENTERING WATER TEMPERATURE (F) _ EXISTING EXP DOOR CONTACT (POSITION SWITCH) •F DC FA FIRE ALARM ELECTRICAL SYMBOLS LEGEND Scale: NONE ABBREVIATION DESCRIPTION A AMPERE AC AIR CONDITIONING ACCU AIR COOLED CONDENSING UNIT AD ACCESS DOOR. AFF ABOVE FINISH FLOOR AHJ AUTHORITY HAVING JURISDICTION AHU AIR HANDLING UNIT AL ALUMINUM SILL APD AIR PRESSURE DROP " WG APPROX APPROXIMATELY AT ALUMINUM THRESHOLD AWG AMERICAN WIRE GAUGE BTU BRITISH THERMAL UNIT BOP BOTTOM OF PIPE BTUH BRITISH THERMAL UNITS PER HOUR CFM CUBIC FEET PER MINUTE CONC CONCRETE CMU CONCRETE MASONRY UNIT CHWS CHILLED WATER SUPPLY CHWR CHILLED WATER RETURN CHWS&R CHILLED WATER SUPPLY & RETURN CRL CARD READER LOCK db DRY BULB (F) DIA, 0 DIAMETER DN DOWN DWG DRAWING EA EXHAUST AIR EAT ENTERING AIR TEMPERATURE EDB ENTERING DRY BULB EER ENERGY EFFICIENCY RATIO EF EXHAUST FAN EH&S ENVIRONMENTAL HEALTH Sc SAFETY EFF EFFICIENCY EM EMERGENCY EMS ENERGY MANAGEMENT SYSTEM ERL EXISTING TO BE RELOCATED ERM EXISTING TO BE REMOVED ESP EXTERNAL STATIC PRESSURE ETR EXISTING TO REMAIN EWB ENTERING WET BULB (F) EWT ENTERING WATER TEMPERATURE (F) EX./EXIST EXISTING EXP EXPOSED •F DEGREES FAHRENHEIT FA FIRE ALARM FACP FIRE ALARM CONTROL PANEL FCU FAN COIL UNIT FD FIRE DAMPER FLA FULL LOAD AMPS FPM FEET PER MINUTE FSD COMBINATION FIRE/SMOKE DAMPER FT OR ' FEET (OF HEAD) GC GENERAL CONSTRUCTION CONTRACTOR GPM GALLONS PER MINUTE GYP GYPSUM BOARD HM HOLLOW METAL HP HORSEPOWER HVAC HEATING, VENTILATION Sc AIR CONDITIONING HWR HOT WATER RETURN HWS HOT WATER SUPPLY HWS&R HOT WATER SUPPLY & RETURN IP INTERIOR PAINT JB ‘ JUNCTION BOX KD KNOCK -DOWN FRAME KW KILOWATTS LAT LEAVING AIR TEMPERATURE (F) LDB LEAVING DRY BULB LWB LEAVING WET BULB LWT LEAVING WATER TEMPERATURE (F) MAX MAXIMUM MBH THOUSAND BTUH MCA MINIMUM CIRCUIT AMPACITY MCB MAIN CIRCUIT BREAKER MDP MAIN DISTRIBUTION PANEL MIN MINIMUM NC NORMALLY CLOSED NO NORMALLY OPEN PD PRESSURE DROP PF PREFINISHED PH PHASE PLAS PLASTER PSI POUNDS PER SQUARE INCH PT PAINT TO MATCH EXISTING PW PLYWOOD RA RETURN AIR RB RUBBER BASE/SILL RF RETURN FAN RL REFRIGERANT LIQUID RS REFRIGERANT SUCTION RRT RUBBER REDUCER STRIP THRESHOLD SA SUPPLY AIR SC SEALED CONCRETE SRI SINGLE READER INTERFACE CARD READER ST STAIN TO MATCH EXISTING TGB TELECOMMUNICATIONS GROUNDING BUSBAR TMGB TELECOMMUNICATIONS MAIN GROUNDING BUSBAR TYP TYPICAL V VOLT VAV VARIABLE AIR VOLUME VB VINYL BASE VCT VINYL COMPOSITION TILE VD VOLUME DAMPER VIF VERIFY IN FIELD VEL VELOCITY WD WOOD WMP WIRE MESH PARTITION XFMR TRANSFORMER n ABBREVIATIONS Scale: NONE J:\PROJECTS-Ithaca\2011\11103 CORNELL - NCP\Uris Library 2010\CAD\ 1 1 103-2010--AMEP-GEN.dwq SCALES ON THIS DRAWING ACCURATE WHEN PLOTTED TO: ARCH El (3OX42 IN.) 0' mom Fie 115 METRO PHONE: ARCH1 TECHNOLOGY, LLC www.archi-technology.com PARK ROCHESTER, NY 14623 585.424.1952 Fax: 585.424.4239 B ARDSLEY DESIGN IATES Architecture, Engineering, Landscape Architecture, P.C. Ph 315.472..6480 5789 Widewaters Parkway Fax 315.478.3523 Dewitt, New York 13214 E-mail 1iFBARBeardsley.cem i.I LLI ce CLIENT: b� uAtp� Cornell University PROJECT �IIIIE ' CONNECTIVITY NETWORK CD 06/29/12 CONSTRUCTION DOCUMENTS 100 DD 05/31 /12 100% DD SUBMISSION 50 DD 50% DD SUBMISSION 20 SD 10/14/11 20% SD SUBMISSION PSD 09/14/11 PRELIMINARY SD SUBMISSION MARK DATE DESCRIPTION CONSTRUCTION DOCUMENTS ISSUE DATE: 06/29/12 co ..s OF NEyr),. -14 N. CUA 0 .. D63153 #AROF. SIONP AT PROJECT NO: 11103-2010 OWNER PROJECT NO: 754 DRAWN BY: LP/EL/PKB CHECKED BY: JLB PROJECT MANAGER: GHS SHEET TITLE: GENERAL NOTES, SYMBOLS AND ABBREVIATIONS (AMEP SERIES) l AMEP-GEN Iffr • 1 Iammom lammi oinimI 2BOOCC 2800- 2304 BASEMENT 2B IDF (ROOM 2604) ARCHITECTURAL - EXISTING / DEMO Scale: 1/2" = 11-0" 1' 2' 4' 11111I1111111111111111111111 I 2800T 2BOOCC BASEMENT 2B MTR-2BA (ROOM 2B04) ARCHITECTURAL - NEW WORK Scale: 1/2" = 11-0" o 1' 2' 4' ARCHITECTURAL — GENERAL NOTES & CONSTRUCTION KEYED NOTES: A. EXISTING CORRIDOR WALLS REQUIRE A 1—HOUR FIRE RATING PER THE BUILDING CODE OF NEW YORK STATE. B. REFER TO DRAWING A4 FOR DETAILS. 0 REMOVE EXISTING WOOD SHELVING, FLOOR TO CEILING. 0 PROVIDE DOOR SWEEP. FOR 1" GAP OR LESS PROVIDE PEMKO #293100CNB, FOR GREATER THAN 1" GAP PROVIDE PEMKO #18137CNB, CLEAR ANODIZED ALUMINUM WITH GRAY NYLON BRUSH INSERT. NOTE: REFER TO DRAWING A4 FOR DETAILS AND SCHEDULES AS APPLICABLE. 2800T rDUCT (ETR) 2804, CONDUITS (ETR) 11 1 2800- REMOVE EA GRILLE AND CAP. BASEMENT 2B IDF (ROOM 2B04) MECHANICAL - EXISTING / REMOVALS Scale: 1/2" = 0 2' 4' arTslii7mmilipmmmmimmommi 2B04 (ETR) REMOVE LIGHT 1 x4 LIGHT (ETR) (ETR 1 2" 2BOOCC BASEMENT 2B IDF (ROOM 2B04) CELECTRICAL - EXISTING / REMOVALS 3 Scale: 1/2" = 1,-0" 0 1' 2' 4' SHUTOFF VALVES (FIR) EX. MAIN CHWS&R (ETR) 2800 / DUCT (ETR) 2804; CONDUITS (ETR) 2BOOCC 3/4" CHWS&R STACKED 3/4" CHWS&R DN TO FCU -1 3/4" CONDENSATE DN TO FCU -1 FCU - 3/4" CONDENSATE REFER TO DRAWING M4 FOR CONTINUATION BASEMENT 2B MTR-2BA (ROOM 2B04) MECHANICAL - NEW WORK Scale: 1/2" = 1'-0" 0 2' 4' 2300CC 2800 CF TR2BA,3 SHUTOFF VALVES SHUTOFF VALVES (ETR) CP TR2BA,1 CP TR2BA,2 2804 (ETR) 1x4 LIGHT (ETR) (FIR 1 2" PANEL P1 , 1 3 BASEMENT 2B MTR-2BA (ROOM 2B04) ELECTRICAL - NEW WORK Scale: 1/2" = 1'-0" 0 1' 2` 4' EX. MAIN CHWS&R (ETR) 3/4" CHWS&R HVAC CONSTRUCTION KEYED NOTES: 0 PROVIDE HIGH SIDEWALL FAN COIL UNIT. MOUNT TOP OF UNIT APPROX. 6'-0" AFF. PROVIDE MOUNTING BRACKET SPACER TO ALLOW FOR INSTALLATION OF CHWS&R AND CONDENSATE PIPE. REFER TO DRAWING M4 FOR UNIT SCHEDULE. NOTE: REFER TO DRAWING M4 FOR DETAILS AND SCHEDULES AS APP CABLE. ELECTRICAL CONSTRUCTION KEYED NOTES: • PROVIDE 2-20A DUPLEX RECEPTACLES IN COMMON BOX, EACH FED FROM DIFFERENT CIRCUIT, MOUNT ABOVE EXISTING DOUBLE DUPLEX OUTLET. @ EX. 4"x12" TMGB TO REMAIN. PROVIDE NEW GROUND CONDUCTORS PER DETAIL ON DRAWING E4. @ PROVIDE NEW LIGHT FIXTURES PER SCHEDULE ON E4. 0 PROVIDE CONVENIENCE OUTLETS AS INDICATED AT 18" UNLESS NOTED OTHERWISE. PROVIDE 3—#12 AWG CONDUCTORS, 3/4" CONDUIT. CONNECT TO EX. RECEPTACLE BRANCH CIRCUIT IN ROOM AS SHOWN (PANEL P1,13). 0 PROVIDE (2) 20A/1P BREAKERS, WITH 6—#10 AWG CONDUCTORS, AND 1" CONDUIT. 0 PROVIDE EM LIGHT, CONNECT TO UNSWITCHED LEG OF EXISTING LIGHTING CIRCUIT. @ REPLACE EX. HEAT DETECTOR WITH SMOKE DETECTOR. PROVIDE ALL SHUT DOWNS TIE—INS AND VERIFICATIONS OF EXISTING ZONED SYSTEM TO MAKE SURE THE ZONE CAN SUPPORT NEW DEVICE(S). PROVIDE TESTING, REPROGRAMMING AND MODIFICATION TO EXISTING FIRE ALARM PANEL AND REMOTE ANNUNCIATORS TO SHOW NEW DEVICE(S). SMOKE DETECTOR SHALL BE INSTALLED AT HIGHEST POINT IN THE CEILING IN THE POCKET AREA. 0 PROVIDE NEW PANEL. 0 EXTEND EX. FIRE ALARM INITIATING CIRCUIT TO NEW SMOKE DETECTOR. PROVIDE ALL SHUT DOWNS, TIE—INS AND VERIFICATIONS OF EXISTING ZONED SYSTEM TO MAKE SURE THE ZONE CAN SUPPORT NEW DEVICE(S). PROVIDE TESTING, REPROGRAMMING AND MODIFICATION TO EXISTING FIRE ALARM PANEL AND REMOTE ANNUNCIATORS TO SHOW NEW DEVICE(S). SMOKE DETECTOR SHALL BE INSTALLED AT HIGHEST POINT IN THE CEILING IN THE CEILING. NOTE: REFER TO DRAWING E4 FOR DETAILS AND SCHEDULES AS APPLICABLE. a JAPROJECTS-Ithaca12011111103 CORNELL - NCP\Uris Library 20101CAD111103-2010--T3-28.dwg SCALES ON THIS DRAWING ACCURATE WHEN PLOTTED TO: ARCH El (30X42 IN.) GENERAL NOTES: A. REFER TO DRAWING AMEP—GEN FOR GENERAL NOTES. B. REFER TO DRAWING T3 -28A FOR ADDITIONAL COORDINATION REQUIREMENTS. MTR-2BA (RM. 2B04) KEY PLAN IMM IPARCHI.TECHNOLOGY, &HA 115 METRO PHONE: LLC www.archi-technology.com PARK ROCHESTER, NY 14623 585.424.1952 Fax: 585.424.4239 ilt ek i BEARDSLEY DESIGN IR IP ASSOCIATES Architecture, Engineering, Landscape Architecture, P.C. Ph 315.472_6980 5789 Widewaters Parkway Fax 315.472.3523 Dewitt, New York 13214 E-mail BDAOSeardsley.cors ....._i 0 I__, 0 NI a >-- Ce < >- f: Z (f) ct LLI Z D LLI Z ce 0 U CO .. I—I < —I U (r) I—I < ce 1 D F— CLIENT: "1---;-\ 4 Cornell University CONNECTIVITY PROJECT c‘A NETWORK - 9• CD 06/29/12 CONSTRUCTICA DOCUMENTS 00 DD 05 , 2 100% DD SUBMISSION 50 DD 50% DD SUBMISSION 20 SD 10/14/11 20% SD SUBMISSION PSD 09/14/11 PRELIMINARY SD SUBMISSION MARK DATE DESCRIPTION CONSTRUCTION DOCUMENTS ISSUE DATE: 06/29/12 .00 c<'0,0 iii117 ,OF NEwk 0140 N. co ° - N.- '.,., 06315'3 .0.D s°** AT PROJECT NO: 1 103-20 0 OWNER PROJECT NO: 754 DRAWN BY: LP/EL/PKB CHECKED BY: JLB PROJECT MANAGER: GHS SHEET TITLE: MTR-2BA PARTIAL PLANS AND KEYNOTES AMEP 2BA