PLOT BY: pbar O PLOT DATE: June EXPANSION ANCHOR CAST IN PLACE 6"W x 8" HEADER W/(2)#4 BARS. BEAR 8" EA. END REMOVE EXISTING CMU FOR NEW LINTEL 7-5/8" 32" x 32" 1-1/2 HR FIRE RATED ACCESS DOOR SAWCUT OPENING. SEE DETAILS CAST IN PLACE LINTEL MILCOR UNIVERSAL FIRE RATED ACCESS DOOR DOOR SIZE: 32" x 32" FRAMED OPENING: 32.5" x 32.5" PRODUCT NUMBER: 3218-032 (1) PADDLE LATCH (4) MASONRY ANCHORS 4'-8" AFF FIRE RATED ACCESS DOOR DETAIL Scale: NONE 3 A4 BOO A ENLARGED PLAN -BASEMENT ROOM BOOTA Scale: 1/2" = 1'-0" 0 1' 2' 4' r / i 1 SEALANT, BOTH SIDES. 3/4" AC GRADE PLYWOOD PAINTED WITH FIRE RETARDANT PAINT, PER SPEC. EXISTING FLOOR/ROOF ASSEMBLY TO REMAIN (SHOWN SHADED). FINISH AS SCHED. SECURE PARTITION TO STRUCTURE AND/OR UNDERSIDE OF FLOOR ASSEMBLY ABOVE. PROVIDE FOR STRUCTURAL DEFLECTION AT CONNECTION PER SPECIFIED MANUFACTURER'S RECOMMENDATION(S). CEILING(S) TO BE REMOVED, WHERE APPLICABLE; AS SCHED. HEIGHTS MAY VARY. 18 GAUGE METAL STUD BRACING OR STRAPPING HORIZONTAL, BEHIND PLYWOOD. LIGHT GAUGE METAL FRAMING, NON—LOADBEARING. SEE SPECS. Ni" TYPE "X" GYPSUM WALL BOARD EACH SIDE, ON 35/8. 18 GUAGE METAL STUDS ON 16" CENTER. WALL BASE, AS SCHED. SEALANT, BOTH SIDES. EXISTING FLOOR ASSEMBLY TO REMAIN (SHOWN SHADED) ,//77/1//Z7/// FULL -HEIGHT PARTITION ASSEMBLY SECTION DETAILS HEAD TYPES NOTE: MATCH FRAME WIDTH (-2") TO EXISTING ADJACENT CONDITIONS. CONTRACTOR TO VERIFY. PARTITION TYPES Scale: NONE GYPSUM WALLBOARD ASSEMBLY PARTITION, AS SCHEDULED. WIDTH MAY VARY. METAL STUD TRACK FRAMING © HEAD. WIDTH AS SCHEDULED. SEALANT, BOTH SIDES. STEEL DOOR FRAME, AS SCHEDULED. THROAT DEPTH MAY VARY. DOOR AND HARDWARE, AS SCHEDULED. JAMB TYPES X0" DOUBLE—STUD METAL FRAMING JAMB(s), BOTH SIDES. WIDTH AS SCHEDULED. STEEL DOOR FRAME, AS SCHEDULED. THROAT DEPTH MAY VARY. SEALANT, BOTH SIDES. NOTE: MATCH FRAME WIDTH (-2") TO EXISTING ADJACENT CONDITIONS. CONTRACTOR TO VERIFY. DOOR AND HARDWARE, AS SCHEDULED. GYPSUM WALLBOARD ASSEMBLY PARTITION, AS SCHEDULED. WIDTH MAY VARY. JAMB AND HEAD TYPES Scale: NONE X X X 2'-8„ ARCHITECTURAL — CONSTRUCTION KEYED NOTES: Al PROVIDE 3-5/8" METAL STUDS, 5/8" WATER RESISTANT GYPSUM WALL BOARD, PAINT WITH TWO COATS OF TNEMEC SERIES 270 POLYAMINE EPDXY OR APPROVED EQUAL. PROVIDE CERAMIC TILE BASE TO MATCH EXISTING HEIGHT. COLOR AS SELECTED FROM MANUFACTURER'S FULL RANGE. CHASE DETAIL Scale: NONE GENERAL NOTES 1. REFER TO DRAWING AMEP—GEN Ni 1, J:\PROJECTS—Ithaca\2011\11103 CORNELL — NCP\Olin Library 2047\CAD\11103-2047--AMEP.dwc1 SCALES ON THIS DRAWING ACCURATE WHEN PLOTTED TO: ARCH El (30X42 IN.) `� �� �� 115 METRO PHONE: a --� O iii a 10, IF SLAY DESIGN ASSOCIATES Architecture, Engineering, Landscape Architecture, P.C. Ph 315.47E_598® 5789 Widewaters Parkway Fax 315.47E_35E3 Dewitt, New York 13214 E-mail BDA@Bearlisley.com IiI CLIENT: O ®uipv NETWORK qw,: Cornell University CONNECTIVITY PROJECT 4'-8" AFF FIRE RATED ACCESS DOOR DETAIL Scale: NONE 3 A4 BOO A ENLARGED PLAN -BASEMENT ROOM BOOTA Scale: 1/2" = 1'-0" 0 1' 2' 4' r / i 1 SEALANT, BOTH SIDES. 3/4" AC GRADE PLYWOOD PAINTED WITH FIRE RETARDANT PAINT, PER SPEC. EXISTING FLOOR/ROOF ASSEMBLY TO REMAIN (SHOWN SHADED). FINISH AS SCHED. SECURE PARTITION TO STRUCTURE AND/OR UNDERSIDE OF FLOOR ASSEMBLY ABOVE. PROVIDE FOR STRUCTURAL DEFLECTION AT CONNECTION PER SPECIFIED MANUFACTURER'S RECOMMENDATION(S). CEILING(S) TO BE REMOVED, WHERE APPLICABLE; AS SCHED. HEIGHTS MAY VARY. 18 GAUGE METAL STUD BRACING OR STRAPPING HORIZONTAL, BEHIND PLYWOOD. LIGHT GAUGE METAL FRAMING, NON—LOADBEARING. SEE SPECS. Ni" TYPE "X" GYPSUM WALL BOARD EACH SIDE, ON 35/8. 18 GUAGE METAL STUDS ON 16" CENTER. WALL BASE, AS SCHED. SEALANT, BOTH SIDES. EXISTING FLOOR ASSEMBLY TO REMAIN (SHOWN SHADED) ,//77/1//Z7/// FULL -HEIGHT PARTITION ASSEMBLY SECTION DETAILS HEAD TYPES NOTE: MATCH FRAME WIDTH (-2") TO EXISTING ADJACENT CONDITIONS. CONTRACTOR TO VERIFY. PARTITION TYPES Scale: NONE GYPSUM WALLBOARD ASSEMBLY PARTITION, AS SCHEDULED. WIDTH MAY VARY. METAL STUD TRACK FRAMING © HEAD. WIDTH AS SCHEDULED. SEALANT, BOTH SIDES. STEEL DOOR FRAME, AS SCHEDULED. THROAT DEPTH MAY VARY. DOOR AND HARDWARE, AS SCHEDULED. JAMB TYPES X0" DOUBLE—STUD METAL FRAMING JAMB(s), BOTH SIDES. WIDTH AS SCHEDULED. STEEL DOOR FRAME, AS SCHEDULED. THROAT DEPTH MAY VARY. SEALANT, BOTH SIDES. NOTE: MATCH FRAME WIDTH (-2") TO EXISTING ADJACENT CONDITIONS. CONTRACTOR TO VERIFY. DOOR AND HARDWARE, AS SCHEDULED. GYPSUM WALLBOARD ASSEMBLY PARTITION, AS SCHEDULED. WIDTH MAY VARY. JAMB AND HEAD TYPES Scale: NONE X X X 2'-8„ ARCHITECTURAL — CONSTRUCTION KEYED NOTES: Al PROVIDE 3-5/8" METAL STUDS, 5/8" WATER RESISTANT GYPSUM WALL BOARD, PAINT WITH TWO COATS OF TNEMEC SERIES 270 POLYAMINE EPDXY OR APPROVED EQUAL. PROVIDE CERAMIC TILE BASE TO MATCH EXISTING HEIGHT. COLOR AS SELECTED FROM MANUFACTURER'S FULL RANGE. CHASE DETAIL Scale: NONE GENERAL NOTES 1. REFER TO DRAWING AMEP—GEN Ni 1, J:\PROJECTS—Ithaca\2011\11103 CORNELL — NCP\Olin Library 2047\CAD\11103-2047--AMEP.dwc1 SCALES ON THIS DRAWING ACCURATE WHEN PLOTTED TO: ARCH El (30X42 IN.) `� �� �� 115 METRO PHONE: ARCHI-TECHNOLOGY, LLC www.archi-technology.com PARK ROCHESTER, NY 14623 585.424.1952 Fax: 585.424.4239 iii a 10, IF SLAY DESIGN ASSOCIATES Architecture, Engineering, Landscape Architecture, P.C. Ph 315.47E_598® 5789 Widewaters Parkway Fax 315.47E_35E3 Dewitt, New York 13214 E-mail BDA@Bearlisley.com IiI CLIENT: ®uipv NETWORK qw,: Cornell University CONNECTIVITY PROJECT CD 06/29/ 12 CONSTRUCTION DOCUMENTS �. 100 DD 05/17/12 100% DD SUBMISSION 50 DD 50% DD SUBMISSION 20 SD 20% SD SUBMISSION PSD 08/05/11 PRELIMINARY SD MARK DATE DESCRIPTION CONSTRUCTION DOCUMENTS ISSUE DATE: 06/29/12 co.0-_totADN.00AI'1° `.© .s,OF NEW Y" °63153 ��� SIONP AT PROJECT NO: 11103-2047 OWNER PROJECT NO: 754 DRAWN BY: PKB CHECKED BY: JLB PROJECT MANAGER: GHS SHEET TITLE: ARCHITECTURAL DETAILS A4 J L d a as 0 J 0- 0) 3 PLOT DATE MTR-SBA EX. PANEL EMPP EX. SECONDARY SWITCHGEAR SUB -BASEMENT - AMEP AREAS OF WORK Scale: 1/40" = 1'-0" 0 40' 80' THIRD FLOOR - AMEP AREAS OF WORK Scale: 1/40" = i'-0" CU SEVENTH FLOOR - AMEP AREAS OF WORK Scale: 1/40" = 1'-0" BASEMENT - AMEP AREAS OF WORK Scale: 1/40" = 1'-0" FOURTH FLOOR - AMEP AREAS OF WORK Scale: 1/40" = 1'-0" ROOF EIGHTH FLOOR - AMEP AREAS OF WORK Scale: 1/40" = 1'-0" FIRST FLOOR - AMEP AREAS OF WORK Scale: 1/40" = 1'-0" FIFTH FLOOR - AMEP AREAS OF WORK Scale: 1/40" = 1'-0" 4 SECOND FLOOR - AMEP AREAS OF WORK Scale: 1/40" = 1'-0" 1-6 EP - SIXTH FLOOR - AMEP AREAS OF WORK Scale: 1/40" = 1'-0" J:\PROJECTS—Ithaca\2011\11103 CORNELL — NCP\❑lin Library 2047\CAD\11103-2047--T1—SZ.dwg SCALES ON THIS DRAWING ACCURATE WHEN PLOTTED TO: ARCH El (30X42 IN.) rm.= 1 El P,ARCHI-TECHNOLOGY, LLC 111.11. www.archi-technology.com PARK ROCHESTER, NY 14623 585.424.1952 Fax: 585.424.4239 115 METRO PHONE: OLIN LIBRARY - 2047 ITHACA, NY CLIENT: : CONNECTIVITY Cornell University PROJECT NETWORK m� CD 06/29/12 CONSTRUCTION DOCUMENTS 100 DD 05/17/12 100% DD SUBMISSION 50 DD 50% DD SUBMISSION 20 SD 20% SD SUBMISSION PSD 08/05/11 PRELIMINARY SD MARK DATE DESCRIPTION CONSTRUCTION DOCUMENTS ISSUE DATE: 06/29/12 cr )iiiifiOAoF:. ..OF NEt4,r 1 ..' i3cuti 083159 SIONA" AT PROJECT NO: 11103-2047 OWNER PROJECT NO: 754 DRAWN BY: PKB CHECKED BY: JLB PROJECT MANAGER: GHS SHEET TITLE: AMEP-AREAS OF WORK t T1AMEP 0- m I- O a 04 O CO N 0) C 4 F- O 0 NET • RKCSNNE TIVITY P LIN LI PROJECT SITE PLAN WIN SMITH HALL 2013 111111111111IIIII1HHIt1 URIS LIBRARY 2010 PAVED PARKING DAY HALL 2026 PUS ST 2088 WILLARD STRAIGHT HALL 2020 BARNES HALL 2009 111111111 µ_ 1111111111 h 1111111 *III DRAWING INDEX DRAWING DESCRIPTION T -COVER DRAWING INDEX AND PROJECT SITE PLAN T -GEN STANDARD SYMBOLS, NOTES, ABBREVIATIONS (T -SERIES) T1 T1 -SZ TR SERVING ZONES, PLAN VIEWS AND BLDG. SEC I ION VIEW Ti -PL PATHWAYS LOGICAL RISER DIAGRAMS Ti -CL COPPER LOGICAL RISER DIAGRAMS T1 -FL FIBER LOGICAL RISER DIAGRAMS T2 T2-SB.CA_CP SUB -BASEMENT PATHWAYS AND CABLING T2-B.CA__CP BASEMENT PATHWAYS AND CABLING T2-B.D.CA_CP BASEMENT PATHWAYS DEMOLITION T2-1.CA_CP FIRST FLOOR PATHWAYS AND CABLING T2-2.CA_CP SECOND FLOOR PATHWAYS AND CABLING T2-3.CA CP THIRD FLOOR PATHWAYS AND CABLING T2-4.CA_CP FOURTH FLOOR PATHWAYS AND CABLING T2 -J. CA CP [II- i it FLOOR PATHWAYS AND CAJLIIVG T2-6.CA CP SIXTH FLOOR PATHWAYS AND CABLING T2-7.CA_CP SEVENTH FLOOR PATHWAYS AND CABLING T2-8.CA_CP EIGHTH FLOOR PATHWAYS AND CABLING T3 T3 -SBA MTR-SBA ENLARGED PLANS AND ELEVATIONS T3 -3A ITR -3A ENLARGED PLANS AND ELEVATIONS T3 -6A ITR -6A ENLARGED PLANS AND ELEVATIONS T3-SBEF SUB -BASEMENT ENTRANCE FACILITY AMEP AMEP-GEN GENERAL NOTES, SYMBOLS AND ABBREVIATIONS (AMEP SERIES) T1-AMEP AMEP-AREAS OF WORK AMEP-SBA MTR-SBA PARTIAL PLANS AND KEYNOTES AMEP-3A ITR -3A PARTIAL PLANS AND KEYNOTES AMEP-6A ITR -6A PARTIAL PLANS AND KEYNOTES A4 ARCHITECTURAL DETAILS M4 MECHANICAL DETAILS E4 ELECTRICAL DETAILS M-2 AMEP ENLARGED PLANS -MECHANICAL JECT J:\PROJECTS-Ithaca\2011\11103 CORNELL - NCP\Olin Library 20471CAD\11103-2047--T-COVER.dwg SCALES ON THIS DRAWING ACCURATE WHEN PLOTTED TO: ARCH El (30X42 IN.) ALCM Vi1 ARCHhTECHNOLOGY, LLC www.archi-technology.com ROCHESTER, NY 14623 Fax: 585.424.4239 115 METRO PARK PHONE: 585.424.1952 CORNELL ITY L 04 ITHACA, NY CLIENT: Cornell University PROJECT //® 4,, NETWORK d - R,9, CONNECTIVITY CD 06/25/ 12 CONSTRUCTION DOCUMENTS 100 DD 05/17/12 100% DD SUBMISSION 50 DD 03/23/12 50% DD SUBMISSION 20 SD 10/07/11 20% SD SUBMISSION PSD 08/26/11 PRELIMINARY SD MARK DATE DESCRIPTION CONSTRUCTION DOCUMENTS ISSUE DATE: 06/2.9% O e . AT PROJECT NO: 11103-2047 OWNER PROJECT NO: 754 DRAWN BY: PKB CHECKED BY: JLB PROJECT MANAGER: GHS SHEET TITLE: DRAWING INDEX AND PROJECT SITE PLAN T -COVER co I- 0 CN N PLOT DATE: GENERAL PROJECT NOTES A. REFER TO A-, E-, AND M -SERIES DRAWINGS FOR AMEP SYMBOLS AND ABBREVIATIONS. B. REFER TO SPECIFICATION (SPEC) SECTION: DIVISION (DIV) 01 WORK UNDER CONTRACT. C. THIS INFORMATION REPRESENTS EXISTING CONDITIONS BASED ON ORIGINAL DRAWINGS AND OBSERVED SITE CONDITIONS. THE CONTRACTOR SHALL FIELD VERIFY EXACT ROUTING, DIMENSIONS AND QUANTITIES. THE CONTRACTOR SHALL DISCONNECT, REMOVE AND RECYCLE/DISPOSE OF ALL EXISTING CABLING AND DEVICES THAT ARE NOT SCHEDULED FOR REUSE. D RACEWAY, CONDUIT, CABLING AND ELECTRICAL/MECHANICAL PATHS ARE SHOWN FOR REFERENCE ONLY. EACH CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS AND SHALL DETERMINE BEST PATHS FOR NEW INSTALLATION THAT WILL CAUSE THE LEAST DISTURBANCE TO OCCUPIED SURROUNDINGS AND BUILDING OPERATIONS (INCLUDING EVENING CLASSES). E EACH CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND PERFORM EXPLORATORY INVESTIGATIONS FOR CONCEALED CONDITIONS AS REQUIRED. EQUIPMENT LOCATIONS AND ROUTES ARE APPROXIMATE AND MINOR ADJUSTMENTS TO THE INSTALLATION WILL BE REQUIRED TO AVOID CONFLICTS WITH EXISTING EQUIPMENT, APPARATUS, AND OCCUPANTS' FURNITURE AND PERSONAL BELONGINGS. F, ALL DRAWINGS ARE SCHEMATIC IN NATURE. THE CONTRACTOR SHALL PROVIDE OFFSETS, ENTRANCE END FITTINGS, RADIUS FITTINGS, HANGERS, ANCHORS, SUPPORT, WIRING AND ACCESSORIES NECESSARY FOR A COMPLETE, OPERATIONAL INSTALLATION. G. IT IS THE RESPONSIBILITY OF EACH CONTRACTOR TO COORDINATE WORK SHOWN ON THEIR CONTRACT DOCUMENTS WITH THE WORK OF OTHER TRADES PRIOR TO SCHEDULING, SHUTDOWN, DEMOLITION, FABRICATION OR INSTALLATION OF ANY WORK OR EQUIPMENT. EQUIPMENT OR DEVICES THAT CANNOT CHANGE LOCATION SHALL TAKE PRECEDENCE OVER THOSE THAT CAN CHANGE LOCATION. ALL TRADES AND CONTRACTS ARE RESPONSIBLE TO REVIEW SITE-SPECIFIC CLASSROOM SCHEDULING (DAILY AND WEEKLY), SPECIAL EVENTS/CONFERENCES, UNIVERSITY ACADEMIC CALENDARS, UNIVERSITY CLOSING AND HOLIDAYS. FACTOR WORK SCHEDULING AND MANPOWER LOADING IN SUCH A WAY SO AS TO MINIMIZE STUDENT AND STAFF DISRUPTIONS. I PROVIDE SCHEDULES AND ONGOING PROGRESS REPORT SUBMITTALS FOR DEMOLITION AND NEW CONSTRUCTION AS CALLED FOR. REFER TO DIV 01 - SUBMITTAL PROCEDURES, AND DIV 01 - PROJECT MEETINGS SPECIFICATION SECTIONS. J. ALL TRADES AND CONTRACTS ARE RESPONSIBLE FOR THEIR OWN DEMOLITION, TEMPORARY FACILITIES, SAFETY PROGRAMS, PATCHING, PAINTING, FIRESTOP, TRASH REMOVAL/DISPOSAL, ROUTINE CLEANING, SPECIAL TELECOMMUNICATION ROOM CLEANING AND FINAL CLEANING, AS CALLED FOR. REFER TO SPEC SECTIONS IN DIV 01 THROUGH AND INCLUDING DIV 09 AS APPLICABLE. K. WHEN DRY CUTTING PLASTER, GYPSUM, CONCRETE MASONRY UNITS OR PLYWOOD - PROVIDE APPROPRIATE DUST AND NOISE CONTROL TEMPORARY PARTITIONS AND MAINTAIN EGRESS AND FIRE ALARM SYSTEM OPERATION. PROVIDE ZIP -WALL DUST BARRIERS OR OTHER APPROPRIATE PROTECTION TO LOCALIZE CLEANUP AND MINIMIZE THE EXTENTS OF FIRE ALARM SHUTDOWNS AND PREVENT FALSE FIRE ALARMS FOR SMALL SCALE CUTTING AND DEMOLITION. WHERE GENERAL CONSTRUCTION WILL CREATE DUST AND DEBRIS, THE CONTRACTOR SHALL PROVIDE PROTECTIVE COVERING FOR FURNITURE, FURNISHINGS AND EQUIPMENT. L. "ERL" ADJACENT TO A DEVICE, FIXTURE OR PIECE OF EQUIPMENT INDICATES AN EXISTING ITEM TO BE RELOCATED. DISCONNECT AND REMOVE THE ITEM. REMOVE ALL UNNECESSARY RACEWAY AND WIRING. REINSTALL AND RECONNECT ITEM AS REQUIRED. M. "ETR" ADJACENT TO A DEVICE, FIXTURE OR PIECE OF EQUIPMENT INDICATES EXISTING ITEM TO REMAIN. MAINTAIN EXISTING CONNECTIONS TO EQUIPMENT UNLESS NOTED OTHERWISE. PROVIDE QUALIFIED TRADES PERSON OR CONTRACTOR TO RESTORE FINISHED WALLS, CEILING AND FLOORS TO ORIGINAL CONDITION AS CALLED FOR IN DIV 01 - CUTTING AND PATCHING. 0. WHERE GENERAL CONSTRUCTION WILL CREATE DUST AND POTENTIAL FALSE SMOKE DETECTOR SIGNALS, THE CONTRACTOR SHALL COORDINATE FIRE ALARM SYSTEM SHUTDOWNS WITH CORNELL EH&S. VISIT SITE PRIOR TO SUBMITTING WRITTEN SHUTDOWN REPORT - TO CONFIRM EXISTING SMOKE DETECTOR LOCATION AND OWNERS' DEVICE/ZONE ADDRESS WITH RESPECT TO LOOK -AHEAD WORK SCHEDULE. REFER TO EXISTING FIRE ALARM DEVICE SCHEDULE, AS APPLICABLE. FALSE FIRE ALARMS CAUSED BY CONSTRUCTION DUST WILL NOT BE TOLERATED. CONTRACTORS ARE RESPONSIBLE TO PAY FOR ANY FINES IMPOSED BY ITHACA/CAYUGA HEIGHTS FIRE DEPARTMENT FOR UNNECESSARY FALSE FIRE ALARMS. P RESTORE AND MAINTAIN AREA FIRE RESISTANCE RATING OF FLOOR AND WALLS. RESTORE AND MAINTAIN AREA SMOKE BARRIERS RATING OF WALLS AND SOFFITS WITH SIMILAR MATERIALS AS CALLED FOR IN DIV 01 - CUTTING AND PATCHING. ALSO REFER TO SPEC SECTION DIV 07 - PENETRATION FIRESTOPPING. Q. FIRESTOP ALL NEW AND EXISTING TELECOM WALL PENETRATIONS AND CONDUIT SLEEVES TO MAINTAIN AREA FIRE RESISTANCE RATING. R. MAINTAIN EXISTING SERVICES AT ALL TIMES DURING NORMAL BUILDING OPERATIONS. PROVIDE TEMPORARY SERVICES AS REQUIRED, OR AS DIRECTED. EXISTING DATA/COMMUNICATIONS CABLE AND OUTLETS SHALL REMAIN DURING THE INSTALLATION OF NEW CABLING AND DEVICES TO MINIMIZE DOWN TIME. COORDINATE CUTOVER TO NEW SYSTEM WITH PROJECT MANAGER. REFER TO SPEC SECTION 27 - COMMISSIONING. ALL TRADES AND CONTRACTS SHALL REPAIR DAMAGED CEILINGS (ANY TYPE), REPLACE LAY -IN CEILING TILES AND GRID WHERE NOTCHED OR DAMAGED FOR EXISTING REMOVALS OR NEW INSTALLATIONS, AS CALLED FOR IN DIV 01 - CUTTING AND PATCHING. REFER TO EXISTING CEILING SCHEDULE ON NEW WORK T2 DRAWINGS. T. PROVIDE BLANK COVERS, FIRE SEAL, CUTTING, AND PATCHING AS REQUIRED TO REPAIR HOLES, UNPAINTED AREAS, OR OTHER PHYSICAL DEFECTS CAUSED BY THE REMOVAL AND INSTALLATION OF EQUIPMENT AND DEVICES. U. PROVIDE ELECTRONIC SUBMITTAL(S) ON ACTUAL PRODUCTS USED VIA PROJECT WEBSITE. INCLUDE COPY OF APPROVED SUBMITTAL WITH CLOSE-OUT DOCUMENTS (IN HARD COPY 0/M MANUAL), REFER TO SECTIONS: 01 33 00 - SUBMITTALS; 01 78 39 - RECORD DOCUMENTS; AND 01 77 00 PROJECT CLOSEOUT AS APPLICABLE. V. DIVISION 27 CONTRACTOR SCOPE: FOR ALL EXISTING SR -4 RACEWAY, THOROUGHLY WIPE DIRT AND DUST FREE FROM ALL REUSED EXISTING SR -4 SERIES RACEWAYS, REMOVE METAL FILINGS FROM INSIDE RACEWAYS AT ALL CONDUIT CONNECTIONS. WHEN RACEWAY IS SHARED WITH ELECTRIC, PROVIDE/MAINTAIN METALLIC SEPARATION BARRIERS, PER NEC CODE. AT LOCATIONS WITH EXISTING ROUND MODULAR OR 4 -PRONG OUTLETS, REMOVE/REPLACE EXISTING SR -4 COVER WITH NEW DEVICE COVER TO CLOSE THE OPEN HOLE (AND PRIME AND PAINT TO MATCH). AT LOCATIONS WITH EXISTING OPENINGS IN EXISTING SR -4, REMOVE/REPLACE EXISTING SR -4 COVER WITH NEW DEVICE COVER TO CLOSE THE OPEN HOLE (AND PRIME AND PAINT TO MATCH). REPLACE EXISTING BENT/DAMAGED OR MISSING SR -4 COVERS (ASSUME 10' OF NEW COVER FOR EVERY 150' OF EXISTING RACEWAY, EVEN IF NOT SPECIFICALLY INDICATED ON THE DRAWINGS). W. CUTOVER OF ACTIVE BACKBONE SERVICES TO BE PERFORMED BY CIT FIELD SERVICES UNLESS OTHERWISE NOTED. END OF NOTES GENERAL REMOVAL NOTES A. AFTER VOICE/DATA CUTOVER, REMOVE EXISTING SURFACE MOUNTED COMMUNICATION OUTLETS AND ASSOCIATED CABLING UNLESS OTHERWISE NOTED TO REMAIN. PATCH AND PAINT AS CALLED FOR. PROVIDE BLANK COVER PLATE TO MATCH EXISTING AS REQUIRED. AFTER VOICE/DATA CUTOVER, AT EXISTING RECESSED COMMUNICATION OUTLETS PROVIDE BLANK COVER PLATE. REMOVE ALL ASSOCIATED CABLING IN ITS ENTIRETY. PROVIDE BLANK COVER PLATE ON ALL EXISTING UNUSED OPENINGS AS WELL. WHFN FXI. TING SURFACE RACEWAY IS cAi FD TO REMAIN FOP REUSE REMOVE EXISTING COMMUNICATIONS FACEPLATES AND CABLING IN THEIR ENTIRETY, AFTER VOICE/DATA CUTOVER, AS CALLED FOR. PROVIDE BLANK PLATE OR REPLACEMENT COVER SECTIONS TO CONCEAL OPENINGS. RECYCLE REMOVED METALLIC COMPONENTS, RACEWAYS AND CABLING TO THE GREATEST EXTENT POSSIBLE. COORDINATE DUMPSTER LOCATION IN ADVANCE WITH THE PROJECT MANAGER. AFTER VOICE/DATA CUTOVER, REMOVE EXISTING CABLING BACK TO SOURCE. REMOVE ALL ASSOCIATED ANCHORS, TERMINAL BLOCKS, AND SPLICE CASES. COORDINATE THE CUTOVER OF ALL REMAINING SYSTEMS WITH THE PROJECT MANAGER. AFTER VOCE/DATA CUTOVER, DISCONNECT AND REMOVE TERMINAL BLOCKS, ENCLOSURE, PLYWOOD BACKBOARD, AND ALL ASSOCIATED CABLING IN THEIR ENTIRETY. PRIOR TO REMOVAL, THE CONTRACTOR SHALL TEST ALL PAIRS FOR SERVICE. COORDINATE THE CUTOVER OF ALL REMAINING SYSTEMS WITH THE PROJECT MANAGER. PATCH AND PAINT WALLS TO MATCH EXISTING AREA IN CORRIDORS AND OFFICE AREAS. G. DISCONNECT AND REMOVE ALL EXISTING DEVICES/WIRING SHOWN FOR REMOVAL, BACK TO SOURCE. MAKE ALL CONNECTIONS NECESSARY TO MAINTAIN EXISTING SYSTEMS WHERE PARTIAL DEMOLITION IS REQUIRED DUE TO SCHEDULING. OLD H. REPLACE CEILING TILES AND CEILING GRID, TO MATCH EXISTING, WHERE NOTCHED FOR EXISTING CONDUITS AND RACEWAYS THAT ARE CALLED TO BE REMOVED. END OF NOTES GENERAL NEW WORK NOTES A. CABLE TRAY, CONDUIT AND RACEWAY ROUTING SHOWN IS DIAGRAMMATIC ONLY. CONTRACTOR TO FIELD VERIFY EXISTING CONDITIONS AND ROUTE PATHWAYS TO AVOID MECHANICAL AND STRUCTURAL CONFLICTS. NOT ALL REQUIRED JUNCTION BOXES AND OFFSETS ARE SHOWN, PROVIDE OFFSETS AND PULLBOXES AS REQUIRED. B. CONTRACTOR SHALL REMOVE AND REPLACE SPLINE CEILINGS TO ACCESS WORK AREAS AS INDICATED ON THE T2-x.CP_CA DRAWINGS. CONTRACTOR SHALL ALSO PROVIDE ACCESS PANELS AT ALL NEW PULLBOXES INSTALLED IN SPLINE CEILINGS. C. WHERE EXISTING PATHWAYS ARE TO REMAIN AND BE REUSED, THE CONTRACTOR SHALL RE -SUPPORT AND PROVIDE RADIUS FITTINGS AS NEEDED TO ENSURE COMPLIANCE WITH SPECIFICATIONS AND UNIVERSITY STANDARDS. D. A PULLBOX SHALL BE INSTALLED FOR RACEWAYS, SIZED AS INDICATED, IN RACEWAY INCREMENTS OF 100 FEET, AND WHEN THE ACCUMULATIVE BEND RADII IS EQUIVALENT TO 180 DEGREES. INSTALL CONDUITS THROUGH PULLBOXES ONLY AS DEPICTED ON STANDARD DETAILS, AND T2-x.CA_CP SERIES DRAWINGS. E. LOCATIONS OF PULLBOXES SHOWN ARE APPROXIMATE - PULLBOXES SHALL BE LOCATED IN AN AREA THAT IS READILY ACCESSIBLE. FIELD VERIFY THE EXACT LOCATIONS. F. THE USE OF CONDUIT BODIES (SMART LB'S) THAT HAVE BUILT-IN BEND RADIUS CONTROL DESIGNED FOR TELECOMMUNICATIONS APPLICATIONS ARE PERMITTED IN ALL COPPER, FIBER AND UTP RISER CONDUITS USED FOR TELECOMMUNICATIONS PATHWAYS. G. THE PULLING TENSION OF UTP CABLES SHALL NOT EXCEED 25 LBS PER CABLE. PROVIDE ADDITIONAL INSTALLERS AT CORNERS AND UTILIZE APPROVED LUBRICANT AS REQUIRED. H. COORDINATE THE ROUTING OF ALL PATHWAYS WITH EXISTING DUCT WORK, PIPING, ELECTRICAL CONDUITS, AND OTHER EXISTING OBSTRUCTIONS. 1. PROVIDE ALL REQUIRED OFFSETS, FABRICATION AND FITTINGS REQUIRED FOR THE INSTALLATION OF CABLE TRAY, CONDUIT, SURFACE RACEWAY, AND CABLE RUNWAY. CABLE TRAY AND CONDUIT SHALL BE INSTALLED CONCEALED UNLESS OTHERWISE NOTED. PAINT EXPOSED CONDUITS, SUPPORTS, PULLBOXES, ETC. REFER TO DIV 09 - INTERIOR PAINTING. J. K. END OF NOTES J:\PROJECTS-Ithaca\2011\11103 CORNELL - NCP\Olin Library 2047\CAD\1 1 103-2047--T-GEN.dw i GENERAL DRAWING NOTES -EXISTING CONDITIONS/REMOVALS- A. ITEMS SHOWN GRAYSCALE ARE EXISTING TO REMAIN UNLESS SPECIFIED OTHERWISE. B. ITEMS SHOWN DASHED -BOLD ARE TO BE REMOVED UNLESS SPECIFIED OTHERWISE. C. EXISTING CONDITIONS HAVE BEEN DOCUMENTED TO THE EXTENT POSSIBLE AT TIME OF SURVEY. TRUST BUT VERIFY ALL EXISTING CONDITIONS ARE AS INDICATED ON "T" SERIES DRAWINGS. REDLINE ON RECORD DRAWINGS ANY DEVIATIONS. END OF NOTES GENERAL DRAWING NOTES -HORIZONTAL CABLING - A. ITEMS SHOWN BOLD ARE NEW WORK UNLESS SPECIFIED OTHERWISE. ITEMS SHOWN IN GRAYSCALE ARE EXISTING TO REMAIN UNLESS SPECIFIED OTHERWISE. C. PROVIDE MANUFACTURER ENGINEERED SOLUTION FOR SMOKE AND FIRE STOPS. D. REFER TO DRAWINGS T1 -CL, T1 -FL, T3-xx, AND SPECIFICATIONS 27 13 00, 27 15 00, 27 05 00, 27 05 53 FOR ADDITIONAL REQUIREMENTS. E. PROVIDE CAT 6A CABLING FOR ALL OUTLETS LOCATIONS WITH A WAP OUTLET DESCRIPTOR. PROVIDE CAT 6 CABLING FOR ALL OTHER OUTLET LOCATIONS WITH NEW CABLING INDICATED. F. ALL NEW CAT 6 AND CAT 6A CABLING SHALL BE NON PLENUM CMR RATED. G. BACKBONE CABLING AND HORIZONTAL CABLING SHALL NOT OCCUPY THE SAME CONDUIT / CABLE TRAY UNLESS APPROVED BY OWNER. END OF NOTES GENERAL DRAWING NOTES -PATHWAYS- A. PATHWAYS - A. ITEMS SHOWN BOLD ARE NEW WORK UNLESS SPECIFIED OTHERWISE. B. ITEMS SHOWN IN GRAYSCALE ARE EXISTING TO REMAIN UNLESS SPECIFIED OTHERWISE. C. REFER TO DRAWINGS T2-x.CA_CP AND T1 -PL FOR HORIZONTAL PATHWAYS. D. REFER TO A-, M-, E -SERIES DRAWINGS FOR ADDITIONAL REQUIREMENTS. E. REFER TO T1 -PL DRAWING FOR ADDITIONAL REQUIREMENTS. F. PATCH/FIRESTOP ALL EXISTING AND NEW CONDUIT CABLE PENETRATIONS IN CORRIDOR WALLS. G. REMOVE LIGHTS AS REQUIRED TO ACCESS ABOVE CEILING LOCATIONS. REPORT ANY EXISTING DAMAGED OR NON -OPERATIONAL LIGHTS TO OWNER'S REPRESENTATIVE PRIOR TO LIGHT REMOVAL. H. EMT TO BE USED IN ALL NEW CONDUIT INSTALLATIONS IF POSSIBLE. FLEX CONDUIT TO BE USED AS LAST RESORT IF FIELD CONDITIONS PREVENT USE OF EMT. IF FLEX CONDUIT IS TO BE USED, IT SHALL BE INCREASED TO ONE TRADE SIZE LARGER THAN REQUIRED FOR EMT. I. PROVIDE BUSHINGS FOR ALL CONDUIT ENDS INSIDE EXISTING & NEW PULLBOXES. J. RE -CONNECT ANY EXISTING CONDUIT BEING REUSED THAT HAS SEPARATED FROM FITTING. K. PERMANENT LABEL NEAT AND LEGIBLE, ALL NEW AND EXISTING PULLBOX COVERS WITH "COMMUNICATIONS ONLY". L. ALL NEW RACEWAY TO BE METALLIC UNLESS OTHERWISE NOTED. M. PROVIDE SPACE SAVER CONDUIT CONNECTORS IN NEW OUTLET BOXES, RACEWAYS AND PULLBOXES. REFER TO SECTION 27 05 28. N. WHERE INDICATED ON THE DRAWINGS, PAINT EXPOSED CONDUITS, SUPPORTS, PULLBOXES, ETC. WHERE INSTALLED IN FINISHED (PUBLIC) NON-MECHANICAL AREAS. REFER TO DIV 09, INTERIOR PAINTING. 0. ALL OUTLETS THAT ARE CALLED TO BE RECESS MOUNTED SHOULD BE IN A DOUBLE GANG BOX. ALL OUTLETS THAT ARE FED VIA SR -2 RACEWAY SHOULD BE ASSUMED TO BE SINGLE GANG SURFACE MOUNT OUTLET BOXES UNLESS OTHERWISE NOTED. P FOR At I FMFRGFNCY AND !NAL L PHONE LOCATIONS THAT CALL FOR SURFACE RACEWAYS ASSUME SR -7 AND ASSOCIATED FITTINGS. Q. ALL EXISTING AND NEW PATHWAYS THAT ARE 2" AND LARGER, AND LONGER THAN 10' SHALL BE BONDED. R. ALL CABLE TRAYS SHALL BE ELECTRICALLY CONTINUOUS. COMMUNICATIONS PATHWAYS THAT END IN CLOSE PROXIMITY TO THE CABLE TRAY SHALL BE BONDED TO THE CABLE TRAY. S. ALL PATHWAYS TERMINATING IN THE MTR\ITR SHALL BE BONDED TO THE TMGB\TGB. T. CABLES SUPPORTED IN J HOOKS SHALL FOLLOW THE J HOOK MANUFACTURERS REQUIREMENTS FOR MOUNTING, SPACING, AND FILL CAPACITY. END OF NOTES ACCESS CONTROL SYMBOLS LEGEND CRt CARD READER LOCK 0 DOOR CONTACT (POSITION SWITCH) SIj SINGLE INPUT READER INTERFACE MODULE T DUAL INPUT READER INTERFACE MODULE TSC INTELLIGENT SYSTEM CONTROLLER (CONTROL PANEL) PATHWAY SCHEDULE - NEW WORK CABLE FILL BASED ON CABLE OD 4 = 0.24 DESIGNATION DESCRIPTION MANUFACTURER PART NO. APPROXIMATE OUTSIDE DIMENSION APPROXIMATE INSIDE DIMENSION CABLE FILL CAPACITYO MIN. BEND RADIUS .75" C = CONDUIT SEE SPEC. SECTION 27 05 28 .75" DIA. 4 4.5" 1" C 1" DIA. 7 6" 1.25" C 1.25" DIA. 13 7.5" 1.5" C 1.5" DIA. 18 9" 2" C 2" DIA. 29 12" 2.5" C 2.5" DIA. 51 25" 3" C 3" DIA. 78 30" 4" C 4" DIA. 130 40" ETR SR -1 NOT USED ELEVATOR PHONE SR -2 ** SURFACE RACEWAY SEE SPEC, SECTION 27 05 28 2400 SERIES SEE SPEC. SECTION 27 05 28 12 GWB SR -3 ** SURFACE RACEWAY 3000 SERIES 32 SR -4 ** SURFACE RACEWAY 4000 SERIES 63 SR -4D ** SURFACE RACEWAY (DIVIDED) 4000D SERIES 30 SR -5 ** SURFACE RACEWAY 5400 SERIES 32 SR -6 ** SURFACE RACEWAY 6000 SERIES 140 SR -6D ** SURFACE RACEWAY (DIVIDED) 6000D SERIES 63 SR -7 SURFACE RACEWAY 700 SERIES 2 SINGLE -MODE OPTICAL FIBER CT -A ENCLOSED TRAY SEE SPEC. SECTION 27 05 28 4"x6" 211 TELECOMMUNICATION GROUND BUS BAR CT -B TELECOMMUNICATIONS MAIN GROUNDING BAR 2"x12" 211 CT -C TELECOMMUNICATIONS ROOM 2"x18" 316 CT -D UNLESS NOTED OTHERWISE 2"x24" 419 CT -E SEE SPEC. SECTION 27 05 28 4"x12" 419 CT -F 6"x12" 632 CT -G 4"x24" 844 CT -H 6"x6" 318 CT -I WIRE DUCI NOT USED 6"x6" 318 CT -3 4"x6" 212 CT -K 4"X9" 318 NOTES: <> 40% MAXIMUM FILL FOR CATEGORY 6 INDICATED (PER TIA / EIA 569-A). - CAT6A CABLING HAS AN OD OF 0.285. - REDUCE FILL RATIO BY 6% FOR EACH 90° BEND - ENSURE THAT FILL RATIOS ARE NOT EXCEEDED 3/4" CONDUIT SHALL ONLY BE ALLOWED AS SPECIFICALLY NOTED ON DRAWINGS. ** REDUCE CAPACITY BY 50% FOR THE FOLLOWING CONDITIONS: - WHEN CONNECTORS ARE MOUNTED WITHIN RACEWAY - WHEN NON -RADIUS FITTINGS RESTRICT CROSS-SECTIONAL AREA - WHEN RACEWAY IS DIVIDED AND SHARED WITH ELECTRIC ALTER EXISTING SURFACE RACEWAY TO PROVIDE AT LEAST TWO 16" SECTIONS OF REMOVABLE COVERS TO ALLOW CABLE ROUGH -IN WITHOUT CONFLICT WITH EXISTING FURNITURE CONFIGURATIONS. ALSO REFER TO GENERAL NOTE "Z" ON T -GEN DRAWING FOR ADDITIONAL SCOPE FOR SURFACE RACEWAYS. WHERE REQUIRED BY RACEWAY CAPACITY, OR AS DIRECTED, PROVIDE SURFACE MOUNT EXTENSION BOX ON EXISTING RACEWAY OPENING TO PROVIDE ADEQUATE CAPACITY AND BEND RADIUS. ALSO REFER TO RACEWAY DERATING REQUIREMENTS AT LEFT. WHERE REQUIRED BY RACEWAY CAPACITY, OR AS DIRECTED, PROVIDE RETROFIT ENTRANCE END FITTING OR ALTER EXISTING BACKFED CONDUIT WITH A NEW SPACE SAVER CONNECTOR TO PROVIDE ADEQUATE CAPACITY AND BEND RADIUS FOR NEW CABLING. ALSO REFER TO RACEWAY DERATING REQUIREMENTS AT LEFT. FIELD VERIFY EXISTING CONDITIONS AND PROPOSE ALTERATIONS THAT MINIMIZE SERVICE DISRUPTION DURATION. PROVIDE ALL TEMPORARY PROVISIONS TO MAINTAIN EXISTING SERVICES. CONDUIT AND CABLE TRAY TO BE ROUTED CONCEALED UNLESS OTHERWISE NOTED. - SCALES ON THIS DRAWING ACCURATE WHEN PLOTTED TO: ARCH El (30X42 IN.) CEILING SCHEDULE 0 SUSPENDED LAY -IN CEILING ® OPEN CEILING © SPLINE CEILING © SUSPENDED PLASTER CEILING ® SUSPENDED PLASTER CEILING OF SUSPENDED GYPSUM CEILING ABBREVIATIONS ACM ASBESTOS CONTAMINATED MATERIAL AP ACCESS PANEL AHJ AUTHORITY HAVING JURISDICTION AWG AMERICAN WIRE GAUGE ARMM ARMORED RISER 24AWG MULTIPAIR CABLE BDF BUILDING DISTRIBUTION FRAME BICSI BUILDING INDUSTRY CONSULTING SERVICES INTERNATIONAL BSC BIO -SAFETY CABINET CCTV CLOSED CIRCUIT TELEVISION CIT CORNELL INFORMATION TECHNOLOGIES CMP COMMUNICATIONS PLENUM RATED CABLE - NEC CMR COMMUNICATIONS RISER RATED CABLE - NEC CTR CIT SUPPORTED EQUIPMENT CABINET WITH ZONE CABLING DDC DIRECT DIGITAL CONTROL SYSTEM DEMARC VERIZON DEMARCATION POINT DN DOWN DOM DEPARTMENT OWNED AND MAINTAINED EF ENTRANCE FACILITY EH&S ENVIRONMENTAL HEALTH AND SAFETY EM EMERGENCY PHONE EMS ENERGY MANAGEMENT SYSTEM ERL "ERL" ADJACENT TO A DEVICE, FIXTURE OR PIECE OF EQUIPMENT INDICATES AN EXISTING ITEM TO BE RELOCATED. DISCONNECT AND REMOVE THE ITEM. REMOVE ALL UNNECESSARY RACEWAY AND WIRING. REINSTALL AND RECONNECT ITEM AS REQUIRED. MAINTAIN SERVICES AS CALLED FOR. ETR "ETR" ADJACENT TO A DEVICE, FIXTURE OR PIECE OF EQUIPMENT INDICATES AN EXISTING ITEM TO REMAIN. MAINTAIN EXISTING CONNECTIONS TO EQUIPMENT UNLESS OTHERWISE NOTED. EV ELEVATOR PHONE FACP FIRE ALARM CONTROL PANEL FO/OF FIBER OPTIC / OPTICAL FIBER FH FUME HOOD GWB GYPSUM WALL BOARD IEEE INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS ITR INTERMEDIATE TELECOMMUNICATIONS ROOM JB JUNCTION BOX LAN LOCAL AREA NETWORK LEC LOCAL EXCHANGE CARRIER / TELCO LS LIFE SAFETY MM MULTI -MODE OPTICAL FIBER MTR MAIN TELECOMMUNICATIONS ROOM OFNR OPTICAL FIBER NON-METALLIC STRENGTH RISER RATED OSHA OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION PB PULL BOX PP PATCH PANEL RAP REMOTE ANNUNCIATION PANEL SM SINGLE -MODE OPTICAL FIBER TC TELECOMMUNICATIONS CONTRACTOR TELCO PUBLIC TELEPHONE COMPANY (VERIZON) TGB TELECOMMUNICATION GROUND BUS BAR TMGB TELECOMMUNICATIONS MAIN GROUNDING BAR TIA TELECOMMUNICATION INDUSTRY ASSOCIATION TR TELECOMMUNICATIONS ROOM TYP TYPICAL UNO UNLESS NOTED OTHERWISE UPS UNINTERRUPTIBLE POWER SUPPLY UTP UNSHIELDED TWISTED PAIR VIF VERIFY IN FIELD VOM VERIZON OWNED AND MAINTAINED WAP WIRELESS ACCESS POINT TELECOM SYMBOLS LEGEND (REV. 02/12) DEMO EXISTING NEW DESCRIPTION 151 IA, ri TELECOM OUTLET - FLOOR BOX © ® ® TELECOM OUTLET - CEILING MOUNTED <1 <T - . TELECOM OUTLET - WALL MOUNTED CLIENT: %.y LOI�1d� ---- CONDUITS - SIZE AS INDICATED —J —J— J -HOOKS - WHERE INDICATED CONDUIT WITH BUSHINGS - TYPE & SIZE AS F --A [ INDICATED PULLBOX: X = SIZE: r---, IPB-XIPB-X L PB X (S) SMALL, (M) MEDIUM, (L) LARGE --J LxWxH LxWxH LxWxH LxWxH = DIMENSIONS IN INCHES `GIRT CTR CTR EQUIPMENT CABINET WITH ZONE CABLING L J1 'IQ, API n ACCESS PANEL - CEILING MOUNT CD xsR-# NSR-# :..IsR-# VERTICAL RACEWAY - DOWN (SR -2 UNO) HsR-# BSR-# HSR-# VERTICAL RACEWAY - UP (SR -2 UNO) Ncr x ICT -x cr x VERTICAL CABLE TRAY - DOWN IIcrx NCT-x ecr-x VERTICAL CABLE TRAY - UP • • • CONDUIT/SLEEVE - UP 0 0 CONDUIT/SLEEVE - DOWN 4 a CONDUIT/SLEEVE - THRU (BETWEEN FLOORS) HORIZONTAL RACEWAY - SIZED PER PATHWAY t�� (sR # I ® SCHEDULE HORIZONTAL CABLE TRAY - SIZED PER KT-- X] CT -x CT -X PATHWAY SCHEDULE DATE M I I I III 1 1 1 1 CABLE RUNWAY X T 1.4 SPLICE CASE E] P ® COMMUNICATIONS POWER POLE - , — I I . SERVING ZONE OR MTR/ITR BOUNDARY IMIUIIS= CTR SERVING ZONE BOUNDARY NEW / EXISTING OUTLET SUBSCRIPT KEY (REFER TO ADDITIONAL DESCRIPTORS THIS DRAWING) 'XXZAI YY "A" ROOM LOCATION CODE "#" EXISTING OUTLET NOTE "xx" EXISTING PATHWAY TYPE TO BE REUSED OUTLET DESCRIPTOR "zz" NEW PATHWAY TYPE ZZ"yy" YY NEW PATHWAY TYPE KEY CC CONDUIT TO CEILING CF CONDUIT TO FLOOR CH CONDUIT TO HALL CI CONDUIT HOMERUN TO ITR/MTR CP CONDUIT TO PULLBOX CT CONDUIT TO CABLE TRAY FW FISHABLE WALL JP J -HOOK TO PULLBOX JS J -HOOK TO SLEEVE JT J -HOOK TO CABLE TRAY PT PULLBOX TO CABLE TRAY SC SURFACE RACEWAY TO CEILING SF SURFACE RACEWAY TO FLOOR SW SURFACE THROUGH WALL SH SURFACE RACEWAY TO HALL (RACEWAY THROUGH ROOM TO HALLWAY PRIMARY HORIZONTAL PATHWAY) DOB NEW DEVICE OPENING IN EXISTING SURFACE RACEWAY, WITH BLANK PLATE (MATCH EXISTING COLOR) NOTE: PROVIDE MINIMUM 1" CONDUIT UNLESS NOTED OTHERWISE. INCREASE SIZE AS REQUIRED PER CABLE FILL CHART. NOTE: PROVIDE MINIMUM SIZE METALLIC RACEWAY BASED ON CABLE FILL CHART UNLESS NOTED OTHERWISE. NOTE: ASSUME PATHWAY TYPE "CP" UNLESS NOTED OTHERWISE. OUTLET DESCRIPTOR KEY ##" HEIGHT ABOVE FINISHED FLOOR (AFF) - EXAMPLE: 48" BAC BUILDING ACCESS CONTROLLER EM EMERGENCY TELEPHONE OUTLET EV ELEVATOR TELEPHONE LINE CONNECTION EMS ENERGY MANAGEMENT FACP FIRE ALARM CONTROL PANEL OC OVER COUNTER MOUNTING W WALL MOUNTED TELEPHONE OUTLET TO BE MOUNTED AT 48" AFF WAP WIRELESS ACCESS POINT - REFER TO DETAIL AT -27052839. EXISTING OUTLET NOTE KEY A EXISTING DEVICE OR OPENING WITH LEGACY CABLING. REMOVE " CABLING, PAINT/PATCH OR PROVIDE BLANK AS APPLICABLE. EXISTING ONE -GANG BOX AND PATHWAYS TO BE REUSED AS %\ INDICATED. MAINTAIN EXISTING SERVICES UNTIL AFTER CUTOVER, THEN REMOVE CABLING. EXISTING TWO -GANG BOX AND PATHWAYS TO BE REUSED AS n INDICATED. MAINTAIN EXISTING SERVICES UNTIL AFTER CUTOVER, THEN REMOVE CABLING. EXISTING OUTLET LOCATION IN SURFACE RACEWAY. PATHWAYS TO BE REUSED AS INDICATED. MAINTAIN ANY EXISTING SERVICE UNTIL AFTER CUTOVER, THEN REMOVE CABLING. PROVIDE DEVICE BRACKETS AS REQUIRED. EXISTING PATHWAYS, BOXES, RACEWAYS AND CAT.5, CAT.5E OR CAT.6 CABLES TO REMAIN. EXISTING PATHWAYS, BOXES AND RACEWAYS TO REMAIN. COORDINATE SHUTDOWN AND CONDUIT/CABLE REWORK TO RELOCATE FROM EXISTING TR TO NEW TR PER T1 -PL, T1 -SZ AND APPENDIX A. REASSIGN CABLE PANEL/PORTS AS CALLED FOR. n EXISTING INTERCOM PHONE IS CONNECTED TO STAND ALONE SYSTEM. OUTLET AND ALL ASSOCIATED WIRING TO REMAIN. EXISTING ONE -GANG BOX AND CONDUIT PATHWAYS DOWN TO Z\ BASEMENT PATHWAY SYSTEM TO BE REUSED AS INDICATED. MAINTAIN EXISTING SERVICES UNTIL AFTER CUTOVER, THEN REMOVE CABLING. EXISTING TWO -GANG BOX AND PATHWAYS DOWN TO BASEMENT A\ PATHWAY SYSTEM TO BE REUSED AS INDICATED. MAINTAIN EXISTING SERVICES UNTIL AFTER CUTOVER, THEN REMOVE CABLING. EXISTING OUTLET LOCATION IN SURFACE RACEWAY. PATHWAYS THROUGH RACEWAY AND DOWN TO BASEMENT PATHWAY SYSTEM TO BE REUSED AS INDICATED. MAINTAIN ANY EXISTING SERVICE UNTIL AFTER CUTOVER, THEN REMOVE CABLING. PROVIDE DEVICE BRACKETS AS REQUIRED. CABLING SYMBOLS LEGEND 26-101-A 1 CABLE IDENTIFICATION LABEL: 2B COMMUNICATIONS EQUIPMENT ROOM 101 MASTER LOCATION CODE A ROOM LOCATION CODE 1 POSITION 1 mai RpARCHI.TECHNOLOGY, AI 115 METRO PHONE: LLC www.archi-technology.com PARK ROCHESTER, NY 14623 585.424.1952 Fax: 585.424.4239 rrH vl CD LU CD >- z U Q i z J` W Z ce CLIENT: %.y LOI�1d� Cornell University PROJECT ��� 7� % CONNECTIVITY NETWORK CD n i v6/29/ � 2 C IST 1 C E 1 .,Olv.�; RUCTION DOCUMENTS 100 DD 05/17/12 100% DD SUBMISSION 50 DD 03/23/12 50% DD SUBMISSION 20 SD 10/07/11 20% SD SUBMISSION PSD 08/26/11 PRELIMINARY SD MARK DATE DESCRIPTION CONSTRUCTION DOCUMENTS ISSUE DATE: 06/29/12 `A14 AT PROJECT NO: 11103-2047 OWNER PROJECT NO: 754 DRAWN BY: PKB CHECKED BY: JLB PROJECT MANAGER: GHS SHEET TITLE: SYMBOLS, ABBREVIATIONS (T t STANDARD NOTES, -SERIES) T -GEN a) c PLOT BY: pb 0 PLOT DATE: J u n ) NOT USED 1 Scale: NONE PROVIDE INSULATION SHIELD & INSERT FOR ALL PIPING BAND HANGER RODS ri.,,,,,,,-----HANGER ROD INSULATION INSULATION SHIELD AT HANGER CHANNEL OR SIDE VIEW ANGLE TRAPEZE HANGER PROVIDE HIGH COMPRESSIVE STRENGTH INSUL INSERT BETWEEN PIPE & INSULATION SHIELD ADJUSTABLE CLEVIS HANGER NOTE: REFER TO PROJECT SPECIFICATION FOR ROD DIAMETER, END CONDITION (CLAMP, ANCHOR, ETC.) HANGER TYPES, AND CONFIGURATION. HANGER ROD INSULATION WELD SADDLE ADJUSTABLE ROLLER HANGER PIPE HANGER Scale: NONE UNISTRUT CONCRETE ANCHORS NOTES: WALL TYPICAL CHILLED WATER PIPE PROVIDE B—LINE ARMAFIX CLAMP OR EQUAL PROVIDE INSULATION CONTINUOUS THROUGH CLAMPS 1. PROVIDE PIPE SUPPORT EVERY 4 FT. — MINIMUM OF 2 SUPPORTS. CHILLED WATER PIPING WALL SUPPORT DETAIL Scale: NONE CONCRETE DECK EXPANSION SHIELDS CONCRETE ANCHORS WASHER (TYPICAL) EXPANSION NAILS NOTE: REFER TO SPECIFICATION FOR REQUIRED ANCHOR CONFIGURATION. 5 PIPE CONCRETE ANCHOR DEVICE DETAIL Scale: NONE PROVIDE ESCUTCHEON PLATES AT ALL PIPE PENETRATIONS EXPOSED TO VIEW. SIZE ESCUTCHEON AROUND INSULATION ON INSULATED PIPE AND AROUND PIPE ON UNISULATED PIPES NON -FIRE RATED WALL SLEEVE WHERE REQUIRED BY SPECIFICATIONS \\\\\\\\\\\\\\\\\ PIPE INSULATION - RUN INSULATION CONTINUOUS THROUGH WALL OPENING. PROVIDE 1" CLEARANCE ALL AROUND NON FIRE RATED WALL PIPE PENETRATION PIPE Scale: NONE PROVIDE ESCUTCHEON PLATES AT ALL PIPE PENETRATIONS EXPOSED TO VIEW. SIZE ESCUTCHEON AROUND INSULATION ON INSULATED PIPE AND AROUND 'PIPE ON UNISULATED PIPES FIRE RATED WALL. SLEEVE WHERE REOUIkLU HY SPECIFICATIONS PIPE INSULATION - BUTT TIGHT TO FIRESTOPPING SYSTEM - PROVIDE FIRESTOPPING SYSTEM PER SPECIFICATIONS FIRE RATED WALL PIPE PENETRATION Scale: NONE ISOLATION VALVE (TYPICAL) FLOW BALANCING VALVE COIL MANUAL AIR VENT MV NOTES: \--UNION/FLANGE (TYPICAL) STRAINER AIR FLOW PETE'S PLUGS (TYPICAL) THERMOMETER (TYPICAL) DRAIN W/HOSE END CONTROL VALVE 1. PIPING TO ALLOW REMOVAL OF COIL WITH OUT REMOVING PIPING BEYOND UNIONS OR FLANGES. 2. FOR UNITS WITH MORE THAN ONE SECTION, PROVIDE FLOW BALANCER, UNIONS/ FLANGES, FLEXIBLE CONNECTORS, DRAINS AND AIR VENTS FOR EACH COIL. TWO-WAY CONTROL VALVE COIL PIPING DETAIL Scale: NONE CON '" F- NECT CONDENSATE HOSE TO ARD PIPE WIT- DIS -WASHER TAILPIECE 3/4" CONDENSATE. HARD PPE SLOPE TO DRAIN LITTLE GIANT CONDENSATE PUMP FC -3 WALL MOUNT SEE ENLARGED VIEW CONDENSATE PUMP DISCHARGE FC -3 CONDENSATE PUMP (MOUNT TO WALL) KEYED NOTES: 1. PROVIDE IN MIN 2D" AIR GAP PROVIDE FUNNEL SIZE LARGE ENOUGH TO PREVENT SPLASHING OF CONDENSATE CONDENSATE PUMP ENLARGED VIEW DIRECT CONDENSATE CONNECTION TO CONDENSATE PUMP. FC -3 CONDENSATE DETAIL L COOLING COIL DRAIN SEE PLANS FOR CONTINUATION NOTE: L =INCH (MINIMUM) H =INCH PLUS THE TOTAL UNIT STATIC PRESSURE AT WORST CASE (LOADED FILTERS) UNDER POSITIVE PRESSURE COOLING COIL DRAIN SEE PLANS FOR CONTINUATION GENERAL NOTES 1. REFER TO DRAWING AMEP—GEN CONNECT TO EXISTING COOLING COIL CONDENSATE DRAIN NOTE: L = H + J + PIPE DIAMETER H = 1 INCH FOR EACH INCH OF NEGATIVE PRESSURE* + 1 INCH J = H * NEGATIVE PRESSURE = TOTAL UNIT STATIC PRESSURE AT WORST CASE (LOADED FILTERS) MINUS EXTERNAL PRESSURE UNDER NEGATIVE PRESSURE CONNECT TO EXISTING COOLING COIL CONDENSATE DRAIN TYPICAL COOLING COIL DRAIN Scale: NONE UNIT LOCATION AIRFLOW ELECTRICAL CHILLED WATER COIL IMBEARADSLEY MOTOR HP (WATTS) V PH FLA EDB EWB LDB LWB TOTAL MBH SENSIBLE MBH EWT LWT GPM FLUID PD MANUF/MAKE NOTES FC -1 MTR—SBA 440 1/10 115 1 1.9 75 63 55.6 54.2 10.8 8.8 52 62 1.7 10 ENVIRO TEC HLE 40 1,2,3,4,5,7 ' FC -2 ITR -3A 510 (62) 115 1 1.2 75 63 55 54 13.4 11.2 52 62 2.5 4.4 EMI WCP-15 2,6,7 FC -3 ITR -6A 245 (23) 115 1 .64 75 63 55 54 6.4 5.3 52 62 1.5 .8 EMI WCP-09 2,6,7 NOTES: 1. PROVIDE STANDALONE CONTROLS WITH FACTORY WALL MOUNTED THERMOSTAT. 2. PROVIDE 1" FILTER 3. PROVIDE SUPPLY DISCHARGE DEFLECTION GRILLE. 4. PROVIDE FAN SPEED CONTROLLER UNIT MOUNTED. 5. PROVIDE BOTTOM HINGED COVER ELECTRICAL ENCLOSURE. 6. PROVIDE UNIT MOUNTED CONTROLS. 7. EWT = 52° DURING WINTER MONTHS. EWT = 47' DURING SUMMER MONTHS. NEW CHILLED WATER FAN COIL UNIT SCHEDULE Scale: NONE I J:\PROJECTS—Ithaca\2011\11103 CORNELL — NCP\Olin Library 2047\CAD\11103-2047--AMEP.dwq SCALES ON THIS DRAWING ACCURATE WHEN PLOTTED TO: ARCH El (30X42 IN.) MA LanARCHhTECHNOLOGY, I LLC www.archi-technology.com PARK ROCHESTER, NY 14623 585.424.1952 Fax: 585.424.4239 115 METRO PHONE: IMBEARADSLEY DESIGN Architecture, Engineering, Landscape Architecture, P.C. Ph 315.472.6980 5789 Widewaters Parkway Fax 315.472,3523 Dewitt, New York 13214 Wmal BBAineardalep.csm I;iI U 0 CLIENT: 0 4 CONNECTIVITY Cornell University PROJECT 11111 -4- NETWORK CD 06/29/12 CONSTRUCTION DOCUMENTS 100 DD 05/17/12 100% DD SUBMISSION 50 DD 50% DD SUBMISSION 20 SD 20% SD SUBMISSION PSD 08/05/11 PRELIMINARY SD MARK DATE DESCRIPTION CONSTRUCTION DOCUMENTS ISSUE DATE: 06/29`12 co. * ,soF NEW ), '• oNDN.c,�0 , , ` 063153 CO rilliP; AT PROJECT NO: 11103-2047 OWNER PROJECT NO: 754 DRAWN BY: PKB CHECKED BY: JLB PROJECT MANAGER: GHS SHEET TITLE: MECHANICAL DETAILS i M4 II II II II II II II II II ii II II II PLOT BY: pba (N PLOT DATE: June 600C 600E0 600EA 600E8 600JB 601 600TA 600JA 3/4" CHWS&R DN TO 3RD FL. REFER TO DETAIL 1 THIS SHEET II II II II II 3/4" CHWS&R II II II II II II II II II II II II II 61 SIXTH FLOOR MECHANICAL - NEW WORK Scale: 3/32" = 1'-0" 0 4' 8' 16' JTR-6A (RM. 625A) SIXTH FLOOR KEY PLAN L±L±H—+oLJ 3/4" CONDENSATE DN TO EX. FLOOR DRAIN 11111111011111111111111111111111111111111111111111 —4 111111111 II II II II II 3/4" CHWS&R UP TO 6TH FL. REFER DETAIL 2, THIS SHEET 3/4" CHWS&R 2801B 2B01A B01 3/4" CONDENSATE PROVIDE CLEANOUTS AT ELBOWS 2800UK EXISTING FLOOR DRAIN 2BOOUA 2802 Ems rum ft s 2 COSA P L.. 128001.N 2BOOUC 3/4" CHWS&R TO MTR—SBA 2BOOUL 2BOOUL 2800T -7 II II II II ii II II II II II THIRD FLOOR MECHANICAL - NEW WORK 2BOOUB 2BOOS x Scale: 3/32" = 1'-0" SHUT OFF VALVE 0 4' 8' 16' SHUT OFF VALVE 3/4" CHWS&R 2 00UE -410 TO EX. 6" CHWS CHILLED (ETR) WATER PUMP ii II II II II II II II II II II II II II II Ii II II II II II II II II II II II II ITR -3A (RM. 325A) OM DN DN 3" CHWR 2BOOUD (ETR) SUB BASEMENT FLOOR MECHANICAL - NEW WORK 3 Scale: 3/32" = 1'-0" 0 4' 8' 16' THIRD FLOOR KEY PLAN 2BOOUE RE—BALANCE EX CHILLED WATER PUMP TO ACCOMMODATE ADDITIONAL 5.7 GPM SUB BASEMENT KEY PLAN II II II II II II II III III II II II II II II II EX. PANEL 38 13251 1325A1 3/4" CHSW&R REFER TO DRAWING AMEP-3A II II II II II II FC -2 II II II II II II 1111 II II GENERAL NOTES: A. REFER TO DRAWING AMEP—GEN. B. REFER TO DRAWINGS AMEP—SBA, AMEP-3A AND AMEP 6—A FOR CONTINUATION AND ADDITIONAL COORDINATION REQUIREMENTS. HVAC CONSTRUCTION KEYED \IOTES: 67Ai') PROVIDE 3/4" CONDENSATE DN TO SINK. PROVIDE DISHWASER TAIL PIECE ON DRAIN PIPE OF SINK. CONNECT 3/4" CONDENSATE HARD PIPE TO DISHWASHER TAIL PIECE WITH 3/4" RUBBER TUBE. NOTE: REFER TO DRAWING M4 FOR DETAILS AND SCHEDULES AS APPLICABLE. EX. 1-1/2" CHWS&R TO REMAIN EX. ECU -i EX. 1" CHWS&R TO REMAIN CONNECT 3/4" CHWS&R TO EX. STUBBED CONNECTION EX. 1" CHWS&R — TO REMAIN IC 200UB HD 200UA SECOND FLOOR (ROOM 236) MECHANICAL - NEW WORK Scale: 3/32" = 1'-0" 0 2' 4' 8' .111111111111=1101111111.111 ITR -3A ABOVE N \ I - I I 3/4" CONDENSATE UP TO FC EX. ECU -2 CONNECT /4" CONDENSATE TO EX. FCU2 CONDENSATE PIPE I 3/4" CHWS&R UP TO FC -2 & FC -3 SECOND FLOOR KEY PLAN JAPROJECTS-Ithaca12011\11103 CORNELL - NCP\Olin Library 2047\CAD\M-2 AMEP ENLARGED PLAN-MECHANICAL.dwg SCALES ON THIS DRAWING ACCURATE WHEN PLOTTED TO: ARCH El (30X42 IN.) r Willi RPARCHITECHNOLOGY 115 METRO PHONE: ‘ tic www.archi-technology.com PARK ROCHESTER, NY 14623 585.424.1952 Fax: 585.424.4239 IMBEARDSLEY DESIGN ASSOCIATES Arhitecture, Engneering, Landscape Architecture, P.C. Ph 315.472.69110 5789 Widewaters Parkway Fax 31$.1.323 Dewitt, New York 13214 E-mail SDASRBeardleyeam N N I fY < › II Clt Ill Z D ......i Lu z ce ce z co ,, _1 u z < II CLIENT: to k ..d111.111 Cornell University PROJECT 0 :lfliflJ ' tA NETWORK qv, ) ZO P• • CONNECTIVITY CD 06/29/12 CONSTRUCTION DOCUMENTS 100 DD 05/17/12 100% DD SUBMISSION 50 DD 03/23/12 50% DD SUBMISSION 20 SD 0/07/11 20% SD SUBMISSION PSD 08/26/11 PRELIMINARY SD ARK DATE DESCRIPTION CONSTRUCTION DOCUMENTS ISSUE DATE: 06/29/12 ,1- <se) ..soF NEW), ‘..- 1---- cr -lir 4.41y....•` 06315'3 #c 15%111); SIONIN.\ - AT PROJECT NO: 11103-2047 OWNER PROJECT NO: 754 DRAWN BY: PKB CHECKED BY: JLB PROJECTMANAGER: GHS SHEET TITLE: AMEP ENLARGED PLANS -MECHANICAL M-2 v . a_ C. 0 C PLOT DATE: PAN 30ARD SC, AUL- NOTES: SE RATED HINGED TRIM Ti COMPUTER GRADE Ti FEED-THRU LUGS 200% NEUTRAL Ti SUB FEED LUGS ❑ SUB -FEED BREAKER Ti ISOLATED GND BUS NAME LOCATION SOURCE RATING (AMPS) CP TRSBA MTR—SBA MCB MLO PH/WIRE VOLTAGE MOUNTING KAIC DESIGN MAKE NEMA TYPE 60A 3 / 4 120/208 SURFACE 10 CKT NO DESCRIPTION BREAKER KVA LOAD PH. A PH. B PH. C <VA LOAD PH. A PH. B PH. C BREAKER DESCRIPTION CKT NO 1 3 5 UPS RECEPTACLE RECEPTACLES ACCESS CONTROL 7 9 11 13 15 17 SPARE SPARE SPARE SPARE SPARE SPARE 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 1.8 0.7 0.1 19 21 23 FEED TO CP TR3A 40/3 1.8 20/1 UPS RECEPTACLE 2 0.7 20/1 RECEPTACLES 4 0.2 20/1 FC -1 6 20/1 SPARE 8 20/1 SPARE 10 20/1 SPARE 12 20/1 SPARE 14 20/1 SPARE 16 20/1 SPARE 18 20/1 SPARE 20 20/1 SPARE 22 20/1 SPARE 24 PAN LOAP3 SC NOTES: SE RATED HINGED TRIM COMPUTER GRADE Ti FEED-THRU LUGS Ti SUB -FEED BREAKER Ti 200% NEUTRAL Ti SUB FEED LUGS Ti ISOLATED GND BUS Ti NAME LOCATION SOURCE RATING (AMPS) CP TR6A ITR -6A MCB MLO PH/WIRE VO LTAG E MOUNTING KAIC DESIGN MAKE NEMA TYPE 60A 3 / 4 120/208 SURFACE 10 CCT NO DESCRIPTION BREAKER KVA LOAD PH. A PH. B PH. C KVA LOAD PH. A PH. B PH. C BREAKER DESCRIPTION CKT NO 1 UPS RECEPTACLE 3 RECEPTACLES 5 FC -3 7 SPARE 9 SPARE 11 SPARE 13 SPARE 15 SPARE 17 SPARE 19 SPARE 21 SPARE 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 1.8 0.7 0.1 23 SPARE 20/1 1.8 20/1 UPS RECEPTACLE 2 0.1 20/1 ACCESS CONTROL 4 20/1 SPARE 6 20/1 20/1 SPARE SPARE 8 10 20/1 SPARE 12 20/1 SPARE 14 20/1 SPARE 16 20/1 SPARE 18 20/1 SPARE 20 20/1 SPARE 22 20/1 SPARE 24 ,AN SCAR J SC AUL NOTES: SE RATED HINGED TRIM COMPUTER GRADE 200% NEUTRAL FEED-THRU LUGS SUB FEED LUGS SUB -FEED BREAKER ISOLATED GND BUS NAME LOCATION SOURCE RATING (AMPS) CP TR3A ITR -3A MCB MLO PH/WIRE VO LTAG E MOU \TING KAIC DESIGN MAKE NEVA TYPE 60A 3 / 4 120/208 SURFACE 10 CKT NO DESCRIP I ION BREAKER <VA LOAD PH. A PH. B PH. C <VA LOAD PH. A PH. B PH. C BREAKER PESCRIPTIrinl LJL lel it I I JIN CCT NO 1 3 UPS RECEPTACLE UPS RECEPTACLE 20/1 1.8 20/1 1 .8 RECEPTACLE 20/1 0.9 7 FC -2 20/1 0.1 9 SPARE 20/1 11 SPARE 20/1 13 SPARE 20/1 15 SPARE 20/1 17 SPARE 20/1 19 21 23 FEED TO CP TR6A 40/3 C 1.8 20/1 UPS RECEPTACLE 2 1.8 20/1 0.1 20/1 20/1 UPS RECEPTACLE ACCESS CONTROL 4 SPARE 6 8 20/1 SPARE 10 20/1 SPARE 12 20/1 SPARE 14 20/1 SPARE 16 20/1 SPARE 18 20/1 SPARE 20 20/1 SPARE 22 20/1 SPARE 24 ELECTRICAL PANELBOARD SCHEDULES Scale: NONE EIGHTH FLOOR SEVENTH FLOOR SIXTH FLOOR FIFTH FLOOR FOURTH FLOOR THIRD FLOOR SECOND FLOOR FIRST FLOOR BASEMENT SUB -BASEMENT GENERAL NOTES 1. REFER TO DRAWING AMEP-GEN ELECTRICAL CONSTRUCTION <EYED NOTES° E1 PROVIDE #6 AWG GROUNDING CONDUCTOR TO ANTI -STATIC FLOOR PIGTAIL. POWER & GROUNDING SYSTEM RISER DIAGRAM 2 ' ` c::: NONE FIXTURE LAMPS REMARKS TYPE I VOLTS MANUFACTURER & CATALOG NUMBER NEW PANEL WITH 60A MAIN BREAKER PANEL CP LAMP CODE #6I 6 WG AWG - ' ITR -6A 4 FT. SURFACE FLUORESCENT WITH HIGH IMPACT ACRYLIC LENS AND ELECTRONIC BALLAST 120/277 LTR6A_ 2 � STEEL..] RM. 625A F032T8/835 - FB 2 FT. SURFACE FLUORESCENT WITH HIGH IMPACT ACRYLIC LENS AND ELECTRONIC BALLAST 120/277 LITHONIA LB-217—MVOLT—GEB101 S 2 17 #3/0, 3/4"C #3/0, 3/4"C 1,2 EM TWIN HEAD EMERGENCY LIGHTING UNIT 120/277 McPHILBEN CFX6 2 5 HALOGEN NOTES: 1. FURNISH WITH <10% THD ELECTRONIC BALLAST. 2. FURNISH WITH HIGH IMPACT PRISMATIC DIFFUSER. 3. PROVIDE 24" PENDANT NEW PANEL _'y�(I WITH 60A MAIN BREAKER I PANEL CP 6 AWG , ITR -3A I TR3A_ ' t TGB_ �� I RM. 325A CD 06/29/12 CONSTRUCTIuN DOCUMENTS 100 DD 05/17/12 100% DD SUBMISSION #6 AWG 50 DD 7-(4) #6 AWG, (1)#8 AWG GROUND, 1"C er #3/0, 3/4"C (4) #4 AWG, (1)#8 AWG GROUND, 1-1/4"C 20 SD 20% SD SUBMISSION (7- PSD 08/05/11 PRELIMINARY SD MARK DATE (4) #4 AWG, (1)#8 AWG EX. PROVIDE PROVIDE GROUND, 1-1/4"C GROUND 60A/3P 60A/3P BUS BREAKER BREAKER CONSTRUCTION DOCUMENTS ISSUE DATE: 06/29/12 <P .,OF NEty (44 NEW --- AT PROJECT NO: 11103-2047 #3/0, 3/4"C 1 PANEL CHECKED BY: JLB PROJECT MANAGER: GHS SHEET TITLE: ELECTRICAL DETAILS • E4 WITH 60A ( ,\ MAIN 6 6 AWG I BREAKER AWG ) 40A/3P PANEL ' MTR-SBA EX. SECONDARY EX. ' SWITCHBOARD ' ' RM. BREAKER I CP TRSBA MUM— STEEL I RM. 2BO1A L SWITCHBOARD EMPP J 2B000H — — — ELECTRICAL CONSTRUCTION <EYED NOTES° E1 PROVIDE #6 AWG GROUNDING CONDUCTOR TO ANTI -STATIC FLOOR PIGTAIL. POWER & GROUNDING SYSTEM RISER DIAGRAM 2 ' ` c::: NONE FIXTURE LAMPS REMARKS TYPE DESCRIPTION VOLTS MANUFACTURER & CATALOG NUMBER QTY. WATTS LAMP CODE FA 4 FT. SURFACE FLUORESCENT WITH HIGH IMPACT ACRYLIC LENS AND ELECTRONIC BALLAST 120/277 LITHONIA CLM-232—MVOLT—GEB 2 32 F032T8/835 1,2,3 FB 2 FT. SURFACE FLUORESCENT WITH HIGH IMPACT ACRYLIC LENS AND ELECTRONIC BALLAST 120/277 LITHONIA LB-217—MVOLT—GEB101 S 2 17 F017T8/835 1,2 EM TWIN HEAD EMERGENCY LIGHTING UNIT 120/277 McPHILBEN CFX6 2 5 HALOGEN NOTES: 1. FURNISH WITH <10% THD ELECTRONIC BALLAST. 2. FURNISH WITH HIGH IMPACT PRISMATIC DIFFUSER. 3. PROVIDE 24" PENDANT LIGHTING FIXTURE SCHEDULE Scale: NONE EIGHTH FLOOR SEVENTH FLOOR SIXTH FLOOR FIFTH FLOOR FOURTH FLOOR THIRD FLOOR SECOND FLOOR FIRST FLOOR BASEM ENT SUB -BASEMENT TMGB OR TGB LABEL 0 PROVIDE ENGRAVED TAG FOR EACH GROUNDING CONDUCTOR, BOTH ENDS AND AT EXPOSED PASS THROUGH MECHANICAL SPACES AND AT ENTRANCES/ EXITS TO SHAFTWAYS, TYPICAL. DIV. 26 CONTRACTOR TO PROVIDE INSULATED TIN PLATED TELECOM SYSTEM GROUND BUS BAR. HOLE CENTERS TO MATCH LUG CONFIGURATION AND EIA/TIA 607 STANDARDS. REFER TO SECTIONS 260526 and 271100. TMGB - ERICO/ERITECH # TMGB-A20L27PT TGB - ERICO/ERITECH # TGB-A20L12PT 02 INSULATORS. 0 5/8" LOCKWASHERS. 0 WALL MOUNTING BRACKET. 0 5/8-11X1" H.H.C,S. BOLTS. 06 DIV. 26 CONTRACTOR TO PROVIDE LONG BARREL COMPRESSION LUG, TWO BOLT, COMPRESSION LUG (BURNDY HYLUG YAZ SERIES) OR EQUAL. PROVIDE A MINIMUM OF EIGHT (8) SPARE LUGS WITH 5/16 HOLES FOR FUTURE USE BY OWNER. DRILL AND TAP AS REQUIRED. SCRUFF BAR AND PROVIDE ANTIOXIDANT AS CALLED FOR. REFER TO SECTIONS 260526 and 271100. TELECOMMUNICATIONS GROUND BAR (TMGB,TGB) DETAIL 4 Scale: NONE J J:\PROJECTS-Ithaca\2011\11103 CORNELL - NCP\Olin Library 2047\CAD\11103-2047--AMEP.dwq SCALES ON THIS DRAWING ACCURATE WHEN PLOTTED TO: ARCH El (30)(42 IN.) vim MPARCHI-TECHNOLOGY, 115 METRO PHONE: �, LLC www.archi-technology.com PARK ROCHESTER, NY 14623 585.424.1952 Fax: 585.424.4239 II 111 DESIGN AIATES Architecture, Engineering, Landscape Architecture, P.C. Ph 315.472.6480 5789 Widewaters Parkway Fax 315.472.3523 Dewitt, New York 13214 E-mail BBA@Beardsley.ensi N li- O N ce Q > ce z m J Q U z_ Q 0 F- (I) ce W z J I LU Z cY O U C IENT: CLIENT: Cornell University PROJECT 0 tfifN v$ ' CONNECTIVITY NETWORK CD 06/29/12 CONSTRUCTIuN DOCUMENTS 100 DD 05/17/12 100% DD SUBMISSION 50 DD 50% DD SUBMISSION 20 SD 20% SD SUBMISSION PSD 08/05/11 PRELIMINARY SD MARK DATE DESCRIPTION CONSTRUCTION DOCUMENTS ISSUE DATE: 06/29/12 <P .,OF NEty (44 063153 ti(/ pROF.SIONP� AT PROJECT NO: 11103-2047 OWNER PROJECT NO: 754 DRAWN BY: PKB CHECKED BY: JLB PROJECT MANAGER: GHS SHEET TITLE: ELECTRICAL DETAILS • E4 PLOT BY: pba PLOT DATE: June 21, 2012 T I I TT I TT 280IA 2B00SA SUB -BASEMENT IDF (ROOM 2B01A) ARCHITECTURAL - EXISTING / DEMO Scale: 1/4" = 1'-0" 0 2' 4' 8' X x 15'-4" +/— ALIGN WITH WIRE MESH PARTITION X x X x x x x x x x x x x x I 11111111111111111111 I f® I I 11.11111111111112 l I i 1 I !• I i111111111111111 I I 1 1 1111111111111 1 2801A UP 2B00SA I 2111221111112 I I l I 111111211111111111 I l 111.111111111i I21111111111111121 1 1 SUB -BASEMENT MTR-SBA (ROOM 2BO1A) ARCHITECTURAL - NEW WORK Scale: 1/4" = 1'-0" 0 2' 4' 8` ARCHITECTURAL — GENERAL NOTES & CONSTRUCTION KEYED NOTES: A. EXISTING AND NEW PARTITIONS ON THIS PLAN ARE NOT FIRE RATED. B. REFER TO DRAWING A4 FOR DETAILS. Al PROVIDE ANTI—STATIC VINYL COMPOSITION FLOOR AND RUBBER BASE. PROVIDE RUBBER TRANSITION STRIP AT EXPOSED EDGE UNDER DOOR. Q PROVIDE 3/4" AC PLYWOOD ON WALLS INDICATED ON THIS PLAN. PRIME AND PAINT WITH FIRE RETARDANT, LIGHT GRAY PAINT ON ALL SURFACES AND EDGES. PLYWOOD TO BE 8 FEET HIGH AND MOUNTED 6 INCHES ABOVE FLOOR. SECURE TO WALL WITH COUNTERSINK FASTENERS 24 INCHES ON CENTER MAXIMUM, EACH WAY. ANCHOR TO STUDS WITH SCREWS. ANCHOR TO CONCRETE OR MASONRY WITH EXPANSION ANCHORS. 0 PAINT WALLS WITHIN ROOM AND NON—ROOM SIDE OF NEW PARTITION. PAINT TYPE AND COLOR TO BE SELECTED BY FACILITIES DEPARTMENT TO MATCH EXISTING PAINT TYPES AND COLOR SCHEMES. 0 PAINT UNDERSIDE OF EXPOSED CONCRETE SLAB ABOVE. PAINT TYPE AND COLOR TO BE SELECTED BY FACILITIES DEPARTMENT TO MATCH EXISTING PAINT TYPES AND COLOR SCHEMES. 0 PROVIDE 3'-0" x 7'—O" x 1-3/4" FLUSH HOLLOW METAL DOOR AND FRAME, NON RATED. PAINT DOOR AND FRAME. PROVIDE HARDWARE AS FOLLOWS: 3 HINGES, STANLEY FBB179 4-1/2 x 4-1/2 1 DOOR CLOSER, SARGENT SERIES 35 1 LOCKSET, SARGENT HARMONY SERIES SARGENT LOCKSET, 8200 SERIES H1, ACCOMMODATE 7 PIN INTERCHANGEABLE BEST CORE. 10 Al MORTISE LOCK ALL LOCKS TO BE STOREROOM LOCKS (04) FAIL SECURE STRIKES: PROVIDE WROUGHT BOXES AND STRIKES WITH PROPER LIP LENGTH TO PROTECT TRIM BUT NOT TO PROTECT MORE THAN 1/8" BEYOND TRIM, FRAME OR INACTIVE LEAF. WHERE REQUIRED, PROVIDE OPEN BACK STRIKE AND PROTECTED TO ALLOW PRACTICAL AND SECURE OPERATION. HARMONY LOCKSETS TO BE INSTALLED BY A CERTIFIED INSTALLER. HARMONY LOCKSETS TO BE INSTALLED BY A CERTIFIED INSTALLER. 1 KEEDEX PART NO. K—DL38A24 DOOR TO FRAME POWER TRANSFER FLEX CONDUIT. 1 McKINNEY ELECTROLYNX RETROFIT CABLE FOR THE DOOR FRAME. SIZE 15'-2". 2 KICKPLATES, 8" x DOOR WIDTH -2", ROCKWOOD 3 RUBBER SILENCERS, GLYNN JOHNSON #64 1 DOOR SWEEP, PEMKO #293100CNB, CLEAR ANODIZED ALUMINUM WITH GRAY NYLON BRUSH INSERT. ALL HARDWARE TO MATCH US10 SATIN BRONZE FINISH. SEE DRAWING A4 FOR DETAIL OD DOOR FRAME IN STUD WALL. PROVIDE PARTITION. 3-5/8" 18 GAUGE METAL STUDS, 16" ON CENTER. 5/8" TYPE X GYPSUM WALL BOARD ON EACH SIDE. PROVIDE 3" ACOUSTIC BATT INSULATION BETWEEN STUDS. PARTITION TO EXTEND TO AND BE SEALED TO UNDERSIDE OF STRUCTURE ABOVE, APPROXIMATELY 8'-11". FIT GYPSUM WALL BOARD AROUND EXISTING PIPES AND CONDUIT. SEAL PENETRATIONS. REMOVE EXISTING DEMOUNTABLE PARTITION/SHELVING SYSTEM AND TURN OVER TO OWNER. REMOVE EXISTING STAINLESS STEEL DRIP PAN. PROVIDE TEMPORARY SUPPORT FOR ALUMINUM CHANNELS WHICH ARE FASTENED TO PARTITION/SHELVING SYSTEM. RE—SECURE TO NEW PARTITION. PROVIDE ROOM SIGNAGE TO MATCH EXISTING BUILDING SIGNAGE. SIGN TEXT AS DIRECTED. REMOVE EXISTING WIRE MESH PARTITION AND REINSTALL AS INDICATED. REMOVE EXISTING BOOK SHELVING AND TURN OVER TO OWNER. NOTE: REFER TO DRAWING A4 FOR DETAILS AND SCHEDULES AS APPLICABLE. X X EX. SPRINKLER LINES (ETR) >� / X (ETR) REMOVE EX. DRAIN PAN AND EX. DRAIN HOSE. !280 A� (ETR) X— x UP 2E r 0,0 REFER TO DRAWING M2 FOR CONTINUATION 3/4" CHWS&R REFER TO DRAWING M2 EX. SPRINKLER LINES (ETR) (ETR) (ETR) U 280 A FC -1 I I l XXXXXXXXX UP HVAC & SPRINKLER SYSTEM CONSTRUCTION <EYED NOTES: 0 PROVIDE NEW CHILLED WATER FAN COIL UNIT. REFER TO DRAWING M4 FOR UNIT SCHEDULE. 0 PROVIDE CONNECTION TO EXISTING BRANCH. PROVIDE ADDITIONAL DRY SIDEWALL SPRINKLER COVERAGE. 0 PROVIDE SPRINKLER COVERAGE FOR MTR—SBA ROOM. COORDINATE SPRINKLER LOCATION WITH LIGHTS, PANELS, CABLE TRAYS AND TELECOMUNICATION EQUIPMENT LOCATIONS. (ERL) REMOVE EX. UPRIGHT SPRINKLER SUB -BASEMENT IDF (ROOM 2BO1A) MECHANICAL - EXISTING / REMOVALS Scale: 1/4" = 1'-0" 0 2' 4' 8' —X X X X x(ERL) x I (ETR) . E2 I E2 I (ETR) 2B01A Immrnmeanowl i® I E2 x ® (EER) SUB -BASEMENT IDF (ROOM 2B01A) ELECTRICAL - EXISTING / REMOVALS X UP 2300SA Scale: 1/4" = 1'-0" 0 2' 4' 8' 1111111111.111121111111111111111111 J:\PROJECTS-Ithaca\2011111103 CORNELL - NCP\Olin Library 2047\CAD\11103-2047--T3-SB.dwg 1280 - REFER TO DRAWING M2 FOR CONTINUATION C5) 1 SUB -BASEMENT MTR-SBA (ROOM 2B01A) MECHANICAL - NEW WORK Scale: 1/4" = 1'-0" 0 2' 4' 8' 111111112111111111111121 (ETR) x(ERL) PROVIDE PANEL 280 8 x I(ETR) CP TRSBA, 3 rJ CP TRSBA, 4 CP TRSBA, 6 (ETR) SUB -BASEMENT MTR-SBA (ROOM 2B01A) ELECTRICAL - NEW WORK UP XX X X XYX XXX X XX \ Scale: 1/4" = 1'-0" 0 2' 4' 8' SCALES ON THIS DRAWING ACCURATE WIEN PLOTTED TO: ARCH El (30)(42 IN.) NOTE: REFER TO DRAWING M4 FOR DETAILS AND SCHEDULES AS APPLICABLE. ELECTRICAL CONSTRUCTION <EYED NOTES: REMOVE EX. LIGHT SWITCH AND WIRING. REMOVE EX. LIGHT FIXTURE AND WIRING. PROVIDE END TERMINATION UNIT FOR LIGHTING TRACK. RE—POSITION EX. SMOKE DETECTOR. REMOVE EXISTING SURFACE METAL RACEWAY AND FEEDER CONDUITS TO FIRST ACCESSIBLE JUNCTION BOX. TAPE AND LABEL CONDUCTORS WITH NAME OF ABANDONED CIRCUIT. PROVIDE TWO 20A DUPLEX RECEPTACLES IN COMMON BOX, EACH FED FROM SEPARATE CIRCUIT. PROVIDE ONE 20A DUPLEX RECEPTACLE. CONNECT TO EX. BRANCH CIRCUIT IN ROOM WHICH PREVIOUSLY FED SURFACE METAL RACEWAY. PROVIDE TMGB PER DETAIL ON DRAWING E4. PROVIDE NEW LIGHT FIXTURES PER SCHEDULE ON DRAWING E4. PROVIDE NEW LIGHT SWITCH, CONNECT TO EX. LIGHT CIRCUIT IN ROOM. PROVIDE EM FIXTURE, CONNECT TO UNSWITCHED LEG OF LIGHT CIRCUIT WHICH FEEDS ROOM. PROVIDE NEW DUPLEX RECEPTACLE AT 24" AFF. EXTEND EXISTING FIRE ALARM CIRCUIT(S) TO NEW SMOKE DETECTOR. SMOKE DETECTOR SHALL BE INSTALLED AT HIGHEST POINT IN THE CEILING IN THE POCKET AREA. PROVIDE ALL SHUT DOWNS, TIE—INS AND VERIFICATIONS OF EXISTING ADDRESSABLE SYSTEM TO ENSURE THAT THE FACP CAN SUPPORT NEW DEVICES. CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR TESTING, REPROGRAMMING AND MODIFICATION TO EXISTING FIRE ALARM PANEL AND REMOTE ANNUNCIATORS TO SHOW NEW DEVICE(S). PROVIDE CIRCUIT FOR ACCESS CONTROL SYSTEM READER INTERFACE MODULE AND ASSOCIATED DOOR LOCK. REMOVE AND RE—POSITION EX. LIGHT SWITCH ON RELOCATED WIRE MESH PARTITION. NOTE: REFER TO DRAWING E4 FOR DETAILS AND SCHEDULES AS APPLICABLE. GENERAL NOTES: A. REFER TO DRAWING AMEP—GEN FOR GENERAL NOTES. B. REFER TO DRAWING M2 FOR CONTINUATION AND ADDITIONAL COORDINATION REQUIREMENTS. C. REFER TO DRAWING T3—SBA FOR ADDITIONAL COORDINATION REQUIREMENTS. KEY PLAN rilMak TIP e 115 METRO PHONE: .1 11, ARCHI-TECHNOLOGY, LLC www.archi-technology.com PARK ROCHESTER, NY 14623 585.424.1952 Fax: 585.424.4239 B SLEY DESIGN ASSOCIATES Architecture, Engineering, Landscape Architecture, P.C. Ph 315.472.6980 5789 Widewaters Parkway Fax 315.472.3.523 Dewitt, New York 13214 E-ffiail B13A'Besrdsley.com I N 4 N Ct >- Ict z m ~ Q ___I U z < O II—I I uJ IF--Ic z J J W Z U CLIENT: ,,=M ® d NETWORK il94. dtb4a a Cornell University J CONNECTIVITY PROJECT Iiii�I eD *® CD 06/29/12 CONSTRUCTION DOCUMENTS 100 DD 05/17/12 100% DD SUBMISSION 50 DD 50% DD SUBMISSION 20 SD 20% SD SUBMISSION PSD 08/05/11 PRELIMINARY SD MARK DATE DESCRIPTION CONSTRUCTION DOCUMENTS ISSUE DATE: 06/29/12 ,.pF NEiryy co i�©NDN. c0 O,A1-- �-sy 063153 P�. SIoN 9AVipp; AT PROJECT NO: 11103-2047 OWNER PROJECT NO: 754 DRAWN BY: PKB CHECKED BY: JLB PROJECT MANAGER: GHS SHEET TITLE: MTR-SBA PARTIAL PLANS AND KEYNOTES AMEPSBA t 0 QCO F- 0 0 0 PLOT DATE: Jun GENERAL NOTES FOR ALL TRADES: A. REFER TO DRAWING "r—GEN" FOR PROJECT NOTES AND ABBREVIATIONS APPLICABLE TO ALL DRAWINGS AND CONTRACTS. REFER TO TABLES ON THIS PAGE FOR DRAWING SYMBOLS AND ABBREVIATIONS PER TRADE. B. REFER TO AMEP—xx DRAWINGS FOR GENERAL NOTES AND KEYED NOTES SPECIFIC TO TRADE. C. THIS INFORMATION REPRESENTS EXISTING CONDITIONS BASED ON ORIGINAL DRAWINGS AND OBSERVED SITE CONDITIONS. NOT ALL ELECTRICAL/MECHANICAL EQUIPMENT IS SHOWN. THE CONTRACTOR SHALL FIELD VERIFY EXACT ROUTING, DIMENSIONS AND QUANTITIES. D. REFER TO MECHANICAL, ELECTRICAL AND COMMUNICATION DRAWINGS FOR ADDITIONAL DEMOLITION AND RENOVATION WITHIN THE INDICATED WORK AREAS. E. REFER TO T2—x.CA_CP DRAWINGS FOR CEILING ACCESS PANEL LOCATIONS. F. REFER TO DRAWING T3—xx DRAWINGS FOR ADDITIONAL COORDINATION REQUIREMENTS. G. GENERAL CONSTRUCTION CONTRACTOR SHALL PERFORM ALL WORK AS SHOWN ON AMEP DRAWINGS, UNLESS NOTED OTHERWISE. REFER TO SPECIFICATIONS 011x00 FOR ADDITIONAL INFORMATION. H. REFER TO THE PROJECT MANUAL/TECHNICAL SPECIFICATION SECTIONS FOR ADDITIONAL PRODUCT AND/OR EXECUTION REQUIREMENTS TO SUPPLEMENT INFORMATION CONTAINED ON THE DRAWINGS. I. CUTTING AND PATCHING OF OPENINGS IN EXISTING BUILDING CONSTRUCTION SHALL BE DONE IN A MANNER WHICH DOES NOT IMPAIR THE STRUCTURAL INTEGRITY OF THE CONSTRUCTION AND MAINTAINS ALL REQUIRED FIRE RATINGS. PATCHING SHALL INCLUDE ALL OPENINGS LEFT IN EXISTING CONSTRUCTION DUE TO DEMOLITION WORK. ALL PATCHED SURFACES ARE TO BE RESTORED AS CLOSELY AS POSSIBLE TO THE ORIGINAL CONDITIONS. ALL PATCHED AREAS REQUIRING PAINT SHALL RECEIVE TWO PRIMER COATS AND TWO FINISH COATS. MATERIALS USED FOR PATCHING SHALL MATCH EXISTING ADJACENT MATERIALS IN BOTH TYPE AND QUALITY. J. NEW ELECTRICAL AND MECHANICAL SYSTEMS WHICH PENETRATE NEW AND EXISTING FIRE RATED FLOORS, WALLS AND OTHER ASSEMBLIES SHALL BE FIRESTOPPED. IN AREAS ACCESSIBLE TO THE PUBLIC, FIRESTOP SYSTEMS SHALL BE SELECTED, INSTALLED AND FINISHED TO THE QUALITY OF ADJACENT SURFACES OF BUILDING CONSTRUCTION BEING PENETRATED. REFER TO SPECIFICATION 078413 FOR ADDITIONAL INFORMATION. K. ALL PLAN DIMENSIONS ARE TO FACE OF PARTITION ASSEMBLY OR FINISH SURFACE (EXCLUDING PLYWOOD BACKBOARDS). L. CONTRACTOR IS TO VERIFY ALL DRAWING DIMENSIONS IN THE FIELD FOR ACCURACY. M. PROVIDE SOFT COPY SUBMITTAL(S) ON ACTUAL PRODUCTS USED. INCLUDE COPY OF APPROVED SUBMITTAL WITH CLOSE OUT DOCUMENTS (IN HARD COPY 0/M MANUAL), REFER TO SECTIONS: 013300 — SUBMITTALS; 017839 — RECORD DOCUMENTS; AND 017700 — PROJECT CLOSEOUT AS APPLICABLE. N. ANY DRILLING, CUTTING ETC. WORK THAT MAY CREATE A NUISANCE FIRE ALARM, NEEDS TO BE SCHEDULED 24 HOURS IN ADVANCE WITH CUSTOMER SERVICE FOR A FIRE PROTECTION SYSTEM SHUTDOWN. SHUTDOWN WILL BE PERFORMED BY EH&S (ENVIRONMENTAL HEALTH AND SAFETY) STAFF. CONTRACTOR WILL NOT DISABLE ANY FIRE PROTECTION EQUIPMENT WITHOUT EH&S APPROVAL/ASSISTANCE. 0. ALL NEW SMOKE DETECTORS AND OTHER FIRE ALARM INITIATION/NOTIFICATION DEVICES WILL NEED TO BE TESTED BY EH&S AND AHJ (AUTHORITY HAVING JURISDICTION) FOR PROPER OPERATION OF DEVICE, DAMPER AND EXHAUST FAN SHUTDOWN. ARCHITECTURAL GENERAL NOTES: A. CLEAN ALL ROOMS DUST FREE FOLLOWING COMPLETION OF DEMOLITION AND PATCHING WORK. B. PROVIDE FIRESTOPPING IN ACCORDANCE WITH SPECIFICATION SECTION 078413 WHERE ITEMS (INCLUDING CABLE TRAYS, PIPES, CONDUIT, FRAMING MEMBERS AND DUCTS) PENETRATE BOTH NEW AND EXISTING FIRE RATED PARTITIONS. FIRE RATED PARTITIONS ARE INDICATED ON ARCHITECTURAL DRAWINGS. FOR SMOKE, FIRE, OR FIRE/SMOKE DAMPERS, TREAT PENETRATION IN ACCORDANCE WITH DAMPER MANUFACTURER'S PRINTED DIRECTIONS. USE OF FIRESTOPPING WILL INVALIDATE UL LISTING OF DAMPER. C. SEAL PENETRATIONS OF BOTH NEW AND EXISTING NON—RATED PARTITIONS INCLUDING CABLE TRAYS, PIPES, CONDUIT, FRAMING MEMBERS AND DUCTS. PROVIDE ELASTOMERIC SEALANT AT GYPSUM WALLBOARD PARTITIONS. PROVIDE MORTAR/GROUT FOR PIPES AND CONDUIT THROUGH MASONRY PARTITIONS. PROVIDE ELASTOM ERIC SEALANT AT EXTERIOR WALLS. I' ( \ INDICATED AS DASHED LINES —REMOVALS D DUCT DROP IN ELEVATION NEW WALL TYPE — REFER TO KEYED NOTES FOR CONSTRUCTION PIPING SYMBOLS 1 0 ROOM NUMBER I 1 ### t- '•' DOUBLE DUPLEX RECEPTACLE OUTLET, 20 AMPERE, 120 VOLT, TOP OF BOX AT 24" AFF UNLESS OTHERWISE NOTED. AIR FLOW EXISTING DOOR TO REMAIN 1771 DUCT - DOWN - POSITIVE PRESSURE- •• DOOR NUMBER (NEW OR EXISTING) L ^ J © NEW DOOR AND FRAME $ MD MOTION DETECTOR, WALL SWITCH TYPE O iii INDICATES 2—HOUR RATED FIRE SEPARATION 1 i 11 DUCT - DOWN -NEGATIVE PRESSURE INDICATES 1 —HOUR RATED FIRE SEPARATION m —44NEW CEILING ACCESS PANEL POWER PANEL [3j ATMOSPHERIC ARCHITECTURAL SYMBOLS LEGEND Scale: NONE HVAC GENERAL NOTES: A. VERIFY ALL EXISTING CONDITIONS. EQUIPMENT LOCATIONS SHOWN ARE APPROXIMATE AND MINOR ADJUSTMENTS TO THE INSTALLATION MAY BE REQUIRED TO AVOID CONFLICTS WITH EXISTING EQUIPMENT AND APPARATUS — EXISTING BRANCH CIRCUITS ARE FROM RECORD DRAWINGS, AND MAY VARY. B. FIELD VERIFY ALL EXISTING CONDITIONS AND DETERMINE THE BEST PATH FOR NEW INSTALLATIONS THAT WILL CAUSE THE LEAST DISTURBANCE TO OCCUPIED SURROUNDINGS. PATHWAYS THAT ARE ROUTED THROUGH MECHANICAL ROOMS, UTILITY ROOMS, STORAGE CLOSETS, ETC. ARE FAVORABLE TO DISTURBANCES IN OCCUPIED AREAS. C. INSTALL ALL EQUIPMENT IN STRICT CONFORMANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS AND RECOMMENDATIONS. D. COORDINATE THE WORK SHOWN ON THESE DRAWINGS WITH THE WORK OF ALL OTHER TRADES PRIOR TO THE FABRICATION OR INSTALLATION OF ANY WORK. EQUIPMENT AND DEVICES THAT CANNOT CHANGE LOCATION SHALL TAKE PRECEDENCE OVER THOSE THAT CAN CHANGE. E. THESE DRAWINGS ARE SCHEMATIC IN NATURE. PROVIDE ALL OFFSETS, HANGERS, ANCHORS, SUPPORTS, WIRING AND ACCESSORIES FOR A COMPLETE, OPERATIONAL INSTALLATION. F. WHERE CEILINGS ARE REMOVED TO ACCOMMODATE NEW TELECOM ROOMS, PROVIDE SUPPORT(S) FOR ALL REMAINING MECHANICAL PIPING, DUCTWORK, MISCELLANEOUS EQUIPMENT, ETC. NOT BEING REMOVED. ALL UNUSED EQUIPMENT & APPURTENANCES SHALL BE REMOVED AND PROPERLY DISPOSED OF. G. ALL EXISTING AND NEW PIPING, DUCTWORK, MECHANICAL EQUIPMENT IN TELECOM ROOMS SHALL BE CLEANED FREE OF DUST/DEBRIS AFTER WALL DEMOLITION AND AFTER WALL RECONSTRUCTION/PATCHING. S3RINKLER SYSTEM GENERAL NOTES: A. PROVIDE GALVANIZED STEEL PIPING TO MATCH EX. GALVANIZED STEEL PIPING. ELECTRICAL GENERAL NOTES: A. VERIFY ALL EXISTING CONDITIONS. EQUIPMENT LOCATIONS SHOWN ARE APPROXIMATE AND MINOR ADJUSTMENTS TO THE INSTALLATION MAY BE REQUIRED TO AVOID CONFLICTS WITH EXISTING EQUIPMENT AND APPARATUS — EXISTING BRANCH CIRCUITS ARE FROM RECORD DRAWINGS, AND MAY VARY. B. FIELD VERIFY ALL EXISTING CONDITIONS AND SHALL DETERMINE THE BEST PATH FOR NEW INSTALLATIONS THAT WILL CAUSE THE LEAST DISTURBANCE TO OCCUPIED SURROUNDINGS. PATHWAYS THAT ARE ROUTED THROUGH MECHANICAL ROOMS, UTILITY ROOMS, STORAGE CLOSETS, ETC. ARE FAVORABLE TO DISTURBANCES IN OCCUPIED AREAS, ALL NEW LUMINAIRES SHALL BE INSTALLED AT A MINIMUM HEIGHT OF 9'-6" AFF UNLESS OTHERWISE NOTED. C. COORDINATE MOUNTING HEIGHT OF ALL NEW POWER OUTLETS WITH THE TELECOMMUNICATIONS SYSTEMS EQUIPMENT ELEVATION DRAWINGS/DETAILS. D. COORDINATE ALL REQUIRED POWER AND FIRE ALARM SHUTDOWNS WITH THE OWNER. PROVIDE MINIMUM 1 WEEK ADVANCE NOTICE. E. WHERE CEILINGS ARE REMOVED TO ACCOMMODATE NEW TELECOM ROOMS, PROVIDE SUPPORT(S) FOR ALL REMAINING ELECTRICAL CONDUITS, DEVICES, EQUIPMENT, ETC. NOT BEING REMOVED. ALL UNUSED EQUIPMENT SHALL BE REMOVED AND PROPERLY DISPOSED OF. F. ALL EXISTING AND NEW CONDUIT AND ELECTRICAL EQUIPMENT IN TELECOM ROOMS SHALL BE CLEANED FREE OF DUST/DEBRIS AFTER WALL DEMOLITION AND AFTER WALL RECONSTRUCTION/ PATCHING. G. PROVIDE GROUNDING IDENTIFICATION AS CALLED FOR. PROVIDE TAGS ON GROUND CONDUCTOR IN ALL SPACES AS DIRECTED AND SHOWN ON GROUNDING DETAIL. H. DURING CONSTRUCTION, PROVIDE HEAT DETECTORS IN TELECOM ROOMS. AT SUBSTANTIAL COMPLETION AND AFTER FINAL CLEANING, CHANGE HEAT DETECTOR TO SMOKE DETECTOR. ALL FIRE ALARM SYSTEM DEVICES SHALL BE TESTED BY EH&S AND AHJ FOR PROPER OPERATION OF DETECTOR, DAMPER, AND FAN SHUTDOWN. MECHANICAL SYMBOLS LEGEND Scale: NONE O ❑ 0 DUCT - UP - NEGATIVE PRESSURE q) �T D DUCT DROP IN ELEVATION LIGHTING FIXTURE, WALL MOUNT PIPING SYMBOLS 1 0 Y. I 1 LIGHTING FIXTURE, FLUORESCENT, CEILING MOUNTED, INDUSTRIAL/STRIP t- '•' DOUBLE DUPLEX RECEPTACLE OUTLET, 20 AMPERE, 120 VOLT, TOP OF BOX AT 24" AFF UNLESS OTHERWISE NOTED. AIR FLOW EM LIGHTING FIXTUREal 1771 DUCT - DOWN - POSITIVE PRESSURE- APD AIR L ^ J © A $ MD MOTION DETECTOR, WALL SWITCH TYPE O JUNCTION BOX, SURFACE MOUNT BRITISH THERMAL UNIT BOP DUCT - DOWN -NEGATIVE PRESSURE DISCONNECT SWITCH VENT —44NEW TO EXISTING CONNECTION POWER PANEL © ATV ATMOSPHERIC PANEL CHILLED WATER SUPPLY CHWR COMPRESSED AIR TELECOMMUNICATIONS GROUNDING BUS BAR CHILLED WATER SUPPLY & RETURN DUCT - UP THRU ROOF - NEGATIVE PRESSURE I!IIfl1 1,i DRY BULB (F) CAPPED DUCT CA DN DOWN DWG DRAWING CONDENSATE DRAIN EXHAUST AIR TELECOMMUNICATIONS MAIN GROUNDING BUS BAR DUCT - UP THRU ROOF - POSITIVE PRESSURE (i s Lj + SINGLE INPUT READER INTERFACE MODULE CD SRI EXHAUST FAN EH&S DUCT TRANSITION FROM RECTANGULAR TO ROUND EFF CHILLED WATER RETURN EM EMERGENCY DUCT - UP - POSITIVE PRESSURE ENERGY MANAGEMENT SYSTEM ►�.� CHWR ERM EXISTING TO BE REMOVED CHILLED WATER SUPPLY & RETURN EXTERNAL STATIC PRESSURE DRI DUCT SIZE - FIRST FIGURE IS SIZE SHOWN CHWS&R ENTERING WET BULB (F) 1:222E DUCT TRANSITION FROM RECTANGULAR TO RECTANGULAR DOOR CONTACT (POSITION SWITCH) EXISTING CHILLED WATER SUPPLY EXPOSED CHWS DEGREES FAHRENHEIT FA FLEXIBLE CONNECTION FACP DOMESTIC COLD WATER 1 % 1 FAN COIL UNIT DCW FIRE DAMPER FLA ri- SQUARE THROAT RADIUS ELBOW t y DHR DOMESTIC HOT WATER RETURN FEET (OF HEAD) ACOUSTICALLY LINED DUCTWORK GENERAL CONSTRUCTION CONTRACTOR GPM ii GYP HOT WATER HM DHW DOMESTIC HORSEPOWER FLEXIBLE DUCT HEATING, VENTILATION & AIR CONDITIONING HWR HOT WATER RETURN SQUARE TO ROUND BRANCH DUCT HOT WATER SUPPLY NATURAL GAS HOT WATER SUPPLY & RETURN IP G JB JUNCTION BOX KD KNOCK—DOWN FRAME KW HOT WATER RETURN LAT LEAVING AIR TEMPERATURE (F) 4---T-------iHWS VOLUME DAMPER HWR LEAVING WET BULB LWT HOT WATER SUPPLY MAX MAXIMUM MBH RECTANGULAR ELBOW WITH TURNING VANES MCA MINIMUM CIRCUIT AMPACITY DUCT WYE MAIN CIRCUIT BREAKER SPRINKLER PIPING MAIN DISTRIBUTION PANEL MIN Jr OR SP NORMALLY CLOSED NO ,i_i, 0 PIPING RISE PF PREFINISHED PH PHASE PLAS PIPING DROP PSI 0 PT PAINT TO MATCH EXISTING RADIUS ELBOW (MIN R/W = 1.5) OS DIGITAL SENSOR RETURN AIR RB CAPPED PIPE RF RETURN FAN 1 -- RS REFRIGERANT SUCTION RRT RUBBER REDUCER STRIP THRESHOLD O THERMOSTAT SC SEALED CONCRETE CEILING GRILLE (G) REGISTER (R) ® DIRECTION OF FLUID FLOW STAIN TO MATCH EXISTING TGB TELECOMMUNICATIONS GROUNDING BUSBAR TMGB TELECOMMUNICATIONS MAIN GROUNDING BUSBAR DN PITCH PIPING DOWN OG THERMOSTAT OR SENSOR WITH GUARD VAV VARIABLE AIR VOLUME VB VINYL BASE IV SHUT OFF VALVE VD VOLUME DAMPER CEILING DIFFUSER (D) O SPRINKLER HEAD (CEILING) WOOD WMP WIRE MESH PARTITION XFMR • SPRINKLER HEAD (ABOVE CEILING) I ID DOOR LOUVER OR UNDER(' IT SPRINKLER HEAD DRY SIDEWALL I— N4 POINT OF DISCONNECT R DUCT RISE IN ELEVATION m MECHANICAL SYMBOLS LEGEND Scale: NONE O ❑ 0 LIGHTING FIXTURE, CEILING MOUNTED q) �T SINGLE RECEPTACLE OUTLET, 20 AMPERE DEDICATED U.P.S. CIRCUIT, 120 VOLT, TOP OF BOX AT 24" AFF SURFACE MOUNTED ON PLYWOOD UNLESS OTHERWISE NOTED. AC LIGHTING FIXTURE, WALL MOUNT Q 9 1 q DUPLEX RECEPTACLE OUTLET, 20 AMPERE, 120 VOLT, TOP OF BOX AT 24" AFF UNLESS OTHERWISE NOTED. I 1 LIGHTING FIXTURE, FLUORESCENT, CEILING MOUNTED, INDUSTRIAL/STRIP t- '•' DOUBLE DUPLEX RECEPTACLE OUTLET, 20 AMPERE, 120 VOLT, TOP OF BOX AT 24" AFF UNLESS OTHERWISE NOTED. AHU EM LIGHTING FIXTUREal 1771 ALUMINUM SILL APD AIR PRESSURE DROP " WG 20 AMPERE, 277 VOLT, SINGLE POLE AC SWITCH, TOP OF BOX AT 48" AFF DEFINITION OF SUBSCRIPTS: 2 TWO POLE SWITCH 3 THREE WAY SWITCH 4 FOUR WAY SWITCH M FRACTIONAL HORSEPOWER, MANUAL MOTOR STARTER W/ THERMAL OVERLOADS abc LOWER CASE LETTER(S) SIGNIFY SWITCHING DESIGNATIONS, QUANTITY OF LETTERS EQUALS QUANTITY OF GANGED SWITCHES. . PP1 /3 BRANCH CIRCUIT HOMERUN, SUBSCRIPT INDICATES PANELBOARD & CIRCUIT DESIGNATION, QUANTITY OF ARROWHEADS DENOTES QUANTITY OF BRANCH CIRCUITS. PROVIDE GREEN GROUND WIRE AND ONE NEUTRAL PER PHASE CONDUCTOR IN EACH CIRCUIT. PROTECT EACH CIRCUIT WITH A 20 AMPERE, 1 -POLE OVERCURRENT DEVICE. UNLESS OTHERWISE INDICATED, MINIMUM WIRE SIZE SHALL BE #10 THHN. $ MD MOTION DETECTOR, WALL SWITCH TYPE O JUNCTION BOX, SURFACE MOUNT BRITISH THERMAL UNIT BOP BOTTOM OF PIPE DISCONNECT SWITCH O FIRE ALARM SYSTEM SMOKE DETECTOR CUBIC FEET PER MINUTE POWER PANEL HD FIRE ALARM SYSTEM HEAT DETECTOR CONCRETE MASONRY UNIT PANEL CHILLED WATER SUPPLY CHWR CHILLED WATER RETURN TELECOMMUNICATIONS GROUNDING BUS BAR CHILLED WATER SUPPLY & RETURN CARD READER LOCK CARD READER LOCK CRL DRY BULB (F) DIA, 0 TGB DN DOWN DWG DRAWING EA EXHAUST AIR TELECOMMUNICATIONS MAIN GROUNDING BUS BAR ENTERING AIR TEMPERATURE EDB ENTERING DRY BULB SINGLE INPUT READER INTERFACE MODULE ENERGY EFFICIENCY RATIO SRI EXHAUST FAN EH&S TMGB EFF EFFICIENCY EM EMERGENCY EMS ENERGY MANAGEMENT SYSTEM - EXISTING TO BE RELOCATED ERM EXISTING TO BE REMOVED DUAL INPUT READER INTERFACE MODULE EXTERNAL STATIC PRESSURE DRI EXISTING TO REMAIN EWB ENTERING WET BULB (F) - ENTERING WATER TEMPERATURE (F) DOOR CONTACT (POSITION SWITCH) EXISTING DC EXPOSED 'F ELECTRICAL SYMBOLS LEGEND Scale: NONE ABBREVIATION DESCRIPTION A AMPERE AC AIR CONDITIONING ACCU AIR COOLED CONDENSING UNIT AD ACCESS DOOR AFF ABOVE FINISH FLOOR AHJ AUTHORITY HAVING JURISDICTION AHU AIR HANDLING UNIT AL ALUMINUM SILL APD AIR PRESSURE DROP " WG APPROX APPROXIMATELY AT ALUMINUM THRESHOLD AWG AMERICAN WIRE GAUGE BTU BRITISH THERMAL UNIT BOP BOTTOM OF PIPE BTUH BRITISH THERMAL UNITS PER HOUR CFM CUBIC FEET PER MINUTE CONC CONCRETE CMU CONCRETE MASONRY UNIT CHWS CHILLED WATER SUPPLY CHWR CHILLED WATER RETURN CHWS&R CHILLED WATER SUPPLY & RETURN CRL CARD READER LOCK db DRY BULB (F) DIA, 0 DIAMETER DN DOWN DWG DRAWING EA EXHAUST AIR EAT ENTERING AIR TEMPERATURE EDB ENTERING DRY BULB EER ENERGY EFFICIENCY RATIO EF EXHAUST FAN EH&S ENVIRONMENTAL HEALTH & SAFETY EFF EFFICIENCY EM EMERGENCY EMS ENERGY MANAGEMENT SYSTEM ERL EXISTING TO BE RELOCATED ERM EXISTING TO BE REMOVED ESP EXTERNAL STATIC PRESSURE ETR EXISTING TO REMAIN EWB ENTERING WET BULB (F) EWT ENTERING WATER TEMPERATURE (F) EX./EXIST EXISTING EXP EXPOSED 'F DEGREES FAHRENHEIT FA FIRE ALARM FACP FIRE ALARM CONTROL PANEL FCU FAN COIL UNIT FD FIRE DAMPER FLA FULL LOAD AMPS FPM FEET PER MINUTE FSD COMBINATION FIRE/SMOKE DAMPER FT OR ' FEET (OF HEAD) GC GENERAL CONSTRUCTION CONTRACTOR GPM GALLONS PER MINUTE GYP GYPSUM BOARD HM HOLLOW METAL HP HORSEPOWER HVAC HEATING, VENTILATION & AIR CONDITIONING HWR HOT WATER RETURN HWS HOT WATER SUPPLY HWS&R HOT WATER SUPPLY & RETURN IP INTERIOR PAINT JB JUNCTION BOX KD KNOCK—DOWN FRAME KW KILOWATTS LAT LEAVING AIR TEMPERATURE (F) LDB LEAVING DRY BULB LWB LEAVING WET BULB LWT LEAVING WATER TEMPERATURE (F) MAX MAXIMUM MBH THOUSAND BTUH MCA MINIMUM CIRCUIT AMPACITY MCB MAIN CIRCUIT BREAKER MDP MAIN DISTRIBUTION PANEL MIN MINIMUM NC NORMALLY CLOSED NO NORMALLY OPEN PD PRESSURE DROP PF PREFINISHED PH PHASE PLAS PLASTER PSI POUNDS PER SQUARE INCH PT PAINT TO MATCH EXISTING PW PLYWOOD RA RETURN AIR RB RUBBER BASE/SILL RF RETURN FAN RL REFRIGERANT LIQUID RS REFRIGERANT SUCTION RRT RUBBER REDUCER STRIP THRESHOLD SA SUPPLY AIR SC SEALED CONCRETE SRI SINGLE READER INTERFACE CARD READER ST STAIN TO MATCH EXISTING TGB TELECOMMUNICATIONS GROUNDING BUSBAR TMGB TELECOMMUNICATIONS MAIN GROUNDING BUSBAR TYP TYPICAL V VOLT VAV VARIABLE AIR VOLUME VB VINYL BASE VCT VINYL COMPOSITION TILE VD VOLUME DAMPER VEL VELOCITY WD WOOD WMP WIRE MESH PARTITION XFMR TRANSFORMER ABBREVIATIONS Scale: NONE J:\PROJECTS—Ithaca\2011\11103 CORNELL — NCP\Olin Library 2047\CAD\11103-2047--AMEP—GEN.dwa SCALES ON THIS DRAWING ACCURATE WHEN PLOTTED TO: ARCH El (30X42 IN.) gm 1 MOIARCHI-TECHNOLOGY, LLC www.archi-technology.com 115 METRO PARK ROCHESTER, NY 14623 PHONE: 585.424.1952 Fax: 585.424.4239 1MBEARDSLEY DESIGN ASSOCIATES Architecture, Engineering, Landscape Architecture, P.C. Ph 315.472.5980 5789 Widewaters Parkway Fax 315.472.3523 Dewitt, New York 13214 E-mail Hi AeBeardsley.eam N o N I r z CO I--1 1<e J U z < I I Z J Cf) C: `W z W Z o U o CLIENT: ,' mea I�� Cornell University PROJECT III NETWORK - 4 CONNECTIVITY CD 06/29/12 CONSTRUCTION DOCUMENTS 100 DD 05/17/12 100% DD SUBMISSION 50 DD 50% DD SUBMISSION 20 SD 10/07/11 20% SD SUBMISSION PSD 08/26/11 PRELIMINARY SD MARK DATE DESCRIPTION CONSTRUCTION DOCUMENTS ISSUE DATE: 06/29/12 �D6315'3 °'ORoF, .\ OF NEWY sioNP~�� AT PROJECT NO: 11103-2047 OWNER PROJECT NO: 754 DRAWN BY: PKB CHECKED BY: JLB PROJECT MANAGER: GHS SHEET TITLE: GENERAL NOTES, SYMBOLS AND ABBREVIATIONS (AMEP SERIES) AMEP-GEN PLOT BY: pba PLOT DATE: June 11111111111111111M I 1 11111111•1111111 I 1 111111111111M I I CID T 00 ID L 625 60OUB IMMO I 1 11111111111111911 I I SIXTH FLOOR (ROOM 625) ARCHITECTURAL - EXISTING / DEMO Scale: 1/4" = 1,-0" 0 2' 4' 8' IIIMMININ I I 111111111110 I I 1111911111111111 I 625 I 60OUB I 1 111111111111111 I I =MEM I N /1 I SIXTH FLOOR ITR -6A (ROOM 625A) ARCHITECTURAL - NEW WORK Scale: 1/4" = 1'-0" 0 2' 4' 8' ARCHITECTURAL — GENERAL NOTES & CONSTRUCTION KEYED NOTES: A. NEW PARTITIONS ON THIS PLAN ARE NOT FIRE RATED. EXISTING PARTITIONS AROUND DUMB WAITER SHAFT (600ED), STAIR, ELEVATOR SHAFT AND ELECTRICAL CHASE ARE 2 HOUR FIRE RATED. B. CLEAN ROOM TO PROVIDE DUST FREE ROOM UPON COMPLETION OF DEMOLITION AND PATCHING WORK. C. REFER TO DRAWING A4 FOR DETAILS AND SCHEDULES. 0 PROVIDE PARTITION. 3-5/8" 18 GUAGE METAL STUDS, 16" ON CENTER. 5/8" TYPE GYPSUM WALL BOARD ON EACH SIDE. PROVIDE 3" ACOUSTIC BATT INSULATION BETWEEN STUDS. PARTITION TO EXTEND TO AND BE SEALED TO UNDERSIDE OF STRUCTURE ABOVE, APPROXIMATELY 8'-4". FIT GYPSUM WALL BOARD AROUND EXISTING PIPES AND CONDUIT. SEAL PENETRATIONS. 0 PROVIDE 3'-0" x 7'-0" x 1-3/4" FLUSH HOLLOW METAL DOOR AND FRAME, NON RATED. PAINT DOOR AND FRAME. PROVIDE HARDWARE AS FOLLOWS: 3 1 0 1aLSOTSAENkEYSAFRBGBEIN7T9 1E/2 ; 4-1/2 1 LOCKSET, SARGENT HARMONY SERIES SARGENT LOCKSET, 8200 SERIES H1, ACCOMMODATE 7 PIN INTERCHANGEABLE BEST CORE. ALL SEE MORTISE LOCK ALL LOCKS TO BE STOREROOM LOCKS (04) FAIL SECURE STRIKES: PROVIDE WROUGHT BOXES AND STRIKES WITH PROPER LIP LENGTH TO PROTECT TRIM BUT NOT TO PROTECT MORE THAN 1/8" BEYOND TRIM, FRAME OR INACTIVE LEAF. WHERE REQUIRED, PROVIDE OPEN BACK STRIKE AND PROTECTED TO ALLOW PRACTICAL AND SECURE OPERATION. HARMONY LOCKSETS TO BE INSTALLED BY A CERTIFIED INSTALLER. KEEDEX PART NO. K-DL38A24 DOOR TO FRAME POWER TRANSFER FLEX CONDUIT. McKINNEY ELECTROLYNX RETROFIT CABLE FOR THE DOOR FRAME. SIZE 15'-2". SET DOOR CONTACTS: SENTROL 1078 FLUSH RECESSED, SENTROL 1038 SURFACE MOUNT KICKPLATES, 8" x DOOR WIDTH -2", ROCKWOOD RUBBER SILENCERS, GLYNN JOHNSON #64 DOOR SWEEP, PEMKO #293100CNB, CLEAR ANODIZED ALUMINUM WITH GRAY NYLON BRUSH INSERT. DOOR STOP, WALL MOUNTED HARDWARE TO MATCH US10 SATIN BRONZE FINISH. DRAWING A4 FOR DETAIL OD DOOR FRAME IN STUD WALL. 0 PAINT WALLS WITHIN ROOM AND NON -ROOM SIDE OF NEW PARTITION. PAINT TYPE AND COLOR TO BE SELECTED BY FACILITIES DEPARTMENT TO MATCH EXISTING PAINT TYPES AND COLOR SCHEMES. 0 PAINT UNDERSIDE OF EXPOSED CONCRETE SLAB ABOVE. PAINT TYPE AND COLOR TO BE SELECTED BY FACILITIES DEPARTMENT TO MATCH EXISTING PAINT TYPES AND COLOR SCHEMES. 0 PROVIDE 3/4" AC PLYWOOD ON WALLS INDICATED ON THIS PLAN. PRIME AND PAINT WITH FIRE RETARDANT, LIGHT GRAY PAINT ON ALL SURFACES AND EDGES. PLYWOOD TO BE 8 FEET HIGH AND MOUNTED 6 INCHES ABOVE FLOOR. SECURE TO WALL WITH COUNTERSINK FASTENERS 24 INCHES ON CENTER MAXIMUM, EACH WAY. ANCHOR TO STUDS WITH SCREWS. ANCHOR TO CONCRETE OR MASONRY WITH EXPANSION ANCHORS. REMOVE EXISTING LIBRARY SHELVING WITH CARE AND TURN OVER TO OWNER. PROVIDE ROOM SIGNAGE TO MATCH EXISTING BUILDING SIGNAGE. SIGN TEXT AS DIRECTED. 0 PROVIDE TWO 3'-0" x 7'-0" x 1-3/4" FLUSH HOLLOW METAL DOORS AND FRAME, NON RATED. PAINT DOOR AND FRAME. PROVIDE HARDWARE AS FOLLOWS: (6) HINGES, STANLEY FBB179 4-1/2 x 4-1/2 (1) CARD READER LOCKSET, SARGENT HARMONY 8200 SERIES, ACCOMMODATE 7 PIN INTERCHANGEABLE BEST CORE. STOREROOM FUNCTION, FAIL SECURE. LOCKSET TO BE INSTALLED BY MANUFACTURER CERTIFIED INSTALLER. 2 MANUAL FLUSHBOLTS, TOP AND BOTTOM ON INACTIVE LEAF 1 POWER TRANSFER, KEEDEX PART # K-DL38A24 1 SET DOOR CONTACTS, SENTROL 1078 FLUSH RECESSED ASTRAGAL, 2" WIDE PAINTED STEEL BLUE. DOOR CLOSER, SARGENT SERIES 351 KICKPLATES, 8" DOOR WIDTH -2" ROCKWOOD 2 RUBBER SILENCERS, GLYNN JOHNSON #64 2 DOOR SWEEP, PEMKO #293100CNB, CLEAR ANODIZED ALUMINUM WITH GREY NYLON BRUSH INSERT 1 2 2 EX. SPRINKLER LINES (ETR) 600 ID (ETR) 625 1 (ETR) (ETR 60OUB / SIXTH FLOOR (ROOM 625) MECHANICAL - EXISTING / REMOVALS ®(ETR) (ET EX. SPRINKLER LINES (ETR) REMOVE EX. SPRINKLER - AND ARM -OVER BACK TO BRANCHLINE. Scale: 1/4" = 1,-0" 0 2' 4' 8' EX. SPRINKLER LINES (ETR) r (ETR) (ETR) PROVIDE MOUNTING SPACER TO ALLOW FOR INSTALLATION OF CONDENSATE PIPING 600UB 3/4" - CONDENSATE PROVIDE CLEANOUTS ,_L AT ELBOWS ETR) j 3/4" CHWS&R REFER TO DWG M2 FOR CONTINUATION SIXTH FLOOR ITR -6A (ROOM 625A) MECHANICAL - NEW WORK Scale: 1/4" = 1'-0" 0 2' 4' 8' 11111.8111.161111111110■11111 EX. SPRINKLER LINES (ETR) HVAC 8c SPRINKLER SYSTEM CONSTRUCTION KEYED NOTES: 0 PROVIDE HIGH SIDEWALL CHILLED WATER FAN COIL UNIT. REFER TO DRAWING M2. REFER TO DRAWING M4 FOR UNIT SCHEDULE. 0 PROVIDE CONNECTION TO EXISTING BRANCHLINE. PROVIDE ADDITIONAL DRY SIDEWALL SPRINKLER COVERAGE FOR ROOM 625A. PROVIDE CALCULATIONS AND SHOP DRAWINGS IN ACCORDANCE WITH SPECIFICATION SECTION 21 13 13. COORDINATE SPRINKLER LOCATION WITH LIGHTS, PANELS, CABLE TRAYS AND TELECOMMUNICATION EQUIPMENT LOCATIONS. 0 PROVIDE PLUG IN OUTLET LEFT BY REMOVALS. 0 PROVIDE WALL MOUNTED CONDENSATE PUMP. PROVIDE INDIRECT CONNECTION FROM FC -3 CONDENSATE TO CONDENSATE PUMP. REFER TO DWG. M4 FOR DETAIL. 0 RELOCATE EXISTING SPRINKLER BRANCH LINE AS REQUIRED BY NEW WALL CONSTRUCTION. 0 PROVIDE CONNECTION TO EXISTING MAIN. PROVIDE ADDITIONAL SPRINKLER COVERAGE. PROVIDE CALCULATIONS AND SHOP DRAWINGS IN ACCORDANCE WITH SPECIFICATION SECTION 21 13 13. NOTE: REFER TO DRAWING M4 FOR DETAILS AND SCHEDULES AS APPLICABLE. EX. POWER PANEL P1 EX. AIR SAMPLING -7 SMOKE DETECTION I CONTROL PANEL Q(ETR) 625 • T 6000B —T VESDA SMOKE (ETR) ALARM SYSTEM PIPING (ETR) (ETE) dET R ) VESDA SMOKE ALARM , of SYSTEM PIPING (ETR) SIXTH FLOOR (ROOM 625) ELECTRICAL - EXISTING / REMOVALS Scale: 1/4" = 1,-0" 0 2' 4 8' INIMENINIME111.11=1 VESDA SMOKE ALARM or SYSTEM ,PIPING (ETR) PROVII E POWE P NE (ETR) 625 EX. POWER PANEL P1 EX. AIR SAMPLING SMOKE DETECTION CONTROL PANEL VESDA SMOKE (ETR) ALARM SYSTEM PIPING (ETR) 600UB o(ETR) SIXTH FLOOR ITR -6A (ROOM 625A ELECTRICAL - NEW WORK V`1.) Scale: 1/4" = 1'-0" 0 2' 4' 1111=11111111111111111.11111 1,2 8' ELECTRICAL CONSTRUCTION KEYED NOTES: REMOVE EX. LIGHT FIXTURE AND WIRING. PROVIDE END TERMINATION UNIT FOR LIGHTING TRACK. PROVIDE TGB PER DETAIL ON DRAWING E4. PROVIDE NEW DUPLEX RECEPTACLE AT 24" AFF UNLESS NOTED OTHERWISE. PROVIDE 20A DUPLEX RECEPTACLE AT 24" AFF. FEED FROM EX. ELECRICAL PANEL P1 IN ADJACENT ROOM, SPARE CIRCUIT #1. PROVIDE TWO 20A DUPLEX RECEPTACLES IN COMMON BOX, EACH FED FROM SEPARATE CIRCUIT. MOUNT AT 24" AFF. PROVIDE NEW LIGHT SWITCH, CONNECT TO EX. LIGHTING BRANCH CIRCUIT IN ROOM. PROVIDE NEW LIGHT FIXTURE PER SCHEDULE ON DRAWING E4. PROVIDE EM LIGHT FIXTURE, CONNECT TO UNSWITCHED LEG OF LIGHT CIRCUIT WHICH FEEDS ROOM. EXTEND EXISTING FIRE ALARM CIRCUIT TO NEW SMOKE DETECTOR. PROVIDE ALL SHUT DOWNS, TIE-INS AND VERIFICATIONS OF EXISTING ADDRESSABLE SYSTEM TO ENSURE THAT THE FACP CAN SUPPORT NEW DEVICES. CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR TESTING, REPROGRAMMING AND MODIFICATION TO EXISTING FIRE ALARM PANEL AND REMOTE ANNUNCIATORS TO SHOW NEW DEVICE(S). PROVIDE CIRCUIT FOR ACCESS CONTROL SYSTEM READER INTERFACE MODULE AND ASSOCIATED DOOR LOCK. DURING CONSTRUCTION, WHILE PARTICULATE IS BEING GENERATED, THE SAMPLING PORTS OF THE VESDA SYSTEM SHALL BE TEMPORARILY COVERED. RECTIFICATION OF TROUBLE SIGNALS GENERATED BY THE VESDA SYSTEM SHALL BE THE CONTRACTORS RESPONSIBILITY. NOTE: REFER TO DRAWING E4 FOR DETAILS AND SCHEDULES AS APPLICABLE. JAPROJECTS-Ithaca12011111103 CORNELL - NCP\Olin Library 2047\CAD\11103-2047--T3-6.dwg SCALES ON THIS DRAWING ACCURATE WHEN PLOTTED TO: ARCH El (30X42 IN.) GENERAL NOTES: A. REFER TO DRAWING AMEP-GEN. B. REFER TO DRAWING M2 FOR CONTINUATION AND ADDITIONAL COORDINATION REQUIREMENTS. C. REFER TO DRAWING T3 -6A FOR ADDITIONAL COORDINATION REQUIREMENTS. KEY PLAN 0, sAmummi witimil MTNARCHI-TECHNOLOGY, `mum, 115 METRO PHONE: u_c www.archi-technology.com PARK ROCHESTER, NY 14623 585.424.1952 Fax: 585.424.4239 111WEARDSLEY DESIGN ASSOCIATES Architecture, Engineering, Landscape Architecture, P.C. Ph 315472_6980 5789 Widewaters Parkway Fax 315.472.3523 Dewitt, New York 13214 E-mail EIDA@Reartisley..eam OLIN LIBRARY - 2047 ITHACA, NY CLIENT: Cornell University PROJECT , ttLJf. NETWORK . /#) 1 ,:u• CONNECTIVITY CD 06/29/12 CONSTRUCTION DOCUMENTS 100 DD 05/17/12 100% DD SUBMISSION 50 DD 50% DD SUBMISSION 20 SD 10/07/11 20% SD SUBMISSION PSD 08/26/11 PRELIMINARY SD MARK DATE DESCRIPTION CONSTRUCTION DOCUMENTS ISSUE DATE: 06/29/12 ( , .'i.- co ,2- ' 4FNE ,0140 N. co -0's 1- Ni- . . jji .11r. .,:,•..,.lir..,Ir ,i4., 063153 (<4, virop7 spoN. AT PROJECT NO: 11103-2047 OWNER PROJECT NO: 754 DRAWN BY: PKB CHECKED BY: JLB PROJECT MANAGER: GHS SHEET TITLE: ITR -6A PARTIAL PLANS AND KEYNOTES AM E P 6A m sa i- 0 N r O a) N 0) C w F- 0 O C� I I® I 1 ® I 1 ® f I 1111111=11111 I I EI I I H HI THIRD FLOOR (ROOM 325) ARCHITECTURAL - EXISTING / DEMO Scale: 1/4" = 1'-0" (ETR) 0 2' 4' 8` EX. SPRINKLER LINES (ETR) (ETR) REMOVE EX. SPRINKLER AND CAP OR PLUG OUTLET IN BRANCH LINE. 325 REMOVE EX. SPRINKLERS/PIPE BACK TO BRANCHLINE. THIRD FLOOR (ROOM 325) MECHANICAL - EXISTING / REMOVALS Scale: 1/4" = 1'-0" • EX. PANEL 3B 0 2' 4' RELOCATE EX. SPRINKLER AWAY FROM NEW WALL. EX. VESDA SMOKE ALARM SYSTEM PIPING (ETR) —T— —T— THIRD FLOOR (ROOM 325) ELECTRICAL - EXISTING / REMOVALS Scale: 1/4" = 11-0" 0 2' 4' 8' J:\PROJECTS-Ithaca\2011111103 CORNELL - NCP\Olin Library 20471CAD111103-2047--T3-3B.dwg THIRD FLOOR ITR -3A (ROOM 325A) 4 ARCHITECTURAL - NEW WORK Scale: 1/4" = V-0" 0 2' 4' 8 3000A (ETR) EX. SPRINKLER LINES (ETR) 325 (ETR) (ETR) PROVIDE MOUNTING SPACER —` TO ALLOW FOR NSTALLATION OF CHWS&R PIPING I 3/4" CONDENSATE DN IN WALL 3/4" CHWS&R DN TO 2ND FL. 3/4" CHWS&R TO FC -3 IN RM. 625A. REFER TO DWG M2 FOR CONTINUATION 6 (ETR) (ETR) CAP OR PLUG OUTLET IN BRANCH LINE. THIRD FLOOR ITR -3A (ROOM 325A) MECHANICAL - NEW WORK ERL) Scale: 1/4" = 1'-0" 0 2' EX. PANEL 3B CP 4` 8` 111111111111 3000A 325 RELOCATE EX_ SPRINKLER AWAY FROM NEW WALL. EX. VESDA SMOKE ALARM SYSTEM PIPING (ETR) 6 PROVID PANEL THIRD FLOOR ITR -3A (ROOM 325A) ELECTRICAL - NEW WORK Scale: 1/4" = 11-0" 0 2' 4' 8' SCALES ON THIS DRAWING ACCURATE WHEN PLOTTED TO: ARCH El (30X42 IN.) ARCHITECTURAL - GENERAL NOTES & CONSTRUCTION KEYED NOTES: A. NEW PARTITIONS ON THIS PLAN ARE NOT FIRE RATED. EXISTING ENCLOSURE OF STAIR, VENTILATION SHAFT, AND ELECTRICAL CHASE ARE 2 HOUR FIRE RATED. B. CLEAN ROOM TO PROVIDE DUST FREE ROOM UPON COMPLETION OF DEMOLITION AND PATCHING WORK. C. REFER TO DRAWING A4 FOR DETAILS AND SCHEDULES. Al PROVIDE PARTITION. 3-5/8" 18 GUAGE METAL STUDS, 16" ON CENTER. 5/8" TYPE GYPSUM WALL BOARD ON EACH SIDE. PROVIDE 3" ACOUSTIC BATT INSULATION BETWEEN STUDS. PARTITION TO EXTEND TO AND BE SEALED TO UNDERSIDE OF STRUCTURE ABOVE, APPROXIMATELY 8'-4". FIT GYPSUM WALL BOARD AROUND EXISTING PIPES AND CONDUIT. SEAL PENETRATIONS. 0 PROVIDE 3'-0" x 7'—O" x 1-3/4" FLUSH HOLLOW METAL DOOR AND FRAME, NON RATED. PAINT DOOR AND FRAME. PROVIDE HARDWARE AS FOLLOWS: 3 HINGES, STANLEY FB6179 4-1/2 x 4-1/2 1 DOOR CLOSER, SARGENT SERIES 35 1 LOCKSET, SARGENT HARMONY SERIES SARGENT LOCKSET, 8200 SERIES H1, ACCOMMODATE 7 PIN INTERCHANGEABLE BEST CORE. MORTISE LOCK ALL LOCKS TO BE STOREROOM LOCKS (04) FAIL SECURE STRIKES: PROVIDE WROUGHT BOXES AND STRIKES WITH PROPER LIP LENGTH TO PROTECT TRIM BUT NOT TO PROTECT MORE THAN 1/8" BEYOND TRIM, FRAME OR INACTIVE LEAF. WHERE REQUIRED, PROVIDE OPEN BACK STRIKE AND PROTECTED TO ALLOW PRACTICAL AND SECURE OPERATION. HARMONY LOCKSETS TO BE INSTALLED BY A CERTIFIED INSTALLER. 1 KEEDEX PART NO. K—DL38A24 DOOR TO FRAME POWER TRANSFER FLEX CONDUIT. 1 McKINNEY ELECTROLYNX RETROFIT CABLE FOR THE DOOR FRAME. SIZE 15'-2". 2 KICKPLATES, 8" x DOOR WIDTH -2", ROCKWOOD 3 RUBBER SILENCERS, GLYNN JOHNSON #64 1 DOOR SWEEP, PEMKO #293100CNB, CLEAR ANODIZED ALUMINUM WITH GRAY NYLON BRUSH INSERT. ALL HARDWARE TO MATCH US10 SATIN BRONZE FINISH. SEE DRAWING A4 FOR DETAIL OD DOOR FRAME IN STUD WALL. A3 PAINT WALLS WITHIN ROOM AND NON—ROOM SIDE OF NEW PARTITION. PAINT TYPE AND COLOR TO BE SELECTED BY FACILITIES DEPARTMENT TO MATCH EXISTING PAINT TYPES AND COLOR SCHEMES. A4 PAINT UNDERSIDE OF EXPOSED CONCRETE SLAB ABOVE. PAINT TYPE AND COLOR TO BE SELECTED BY FACILITIES DEPARTMENT TO MATCH EXISTING PAINT TYPES AND COLOR SCHEMES. A5 PROVIDE 3/4" AC PLYWOOD ON WALLS INDICATED ON THIS PLAN. PRIME AND PAINT WITH FIRE RETARDANT, LIGHT GRAY PAINT ON ALL SURFACES AND EDGES. PLYWOOD TO BE 8 FEET HIGH AND MOUNTED 6 INCHES ABOVE FLOOR. SECURE TO WALL WITH COUNTERSINK FASTENERS 24 INCHES ON CENTER MAXIMUM, EACH WAY. ANCHOR TO STUDS WITH SCREWS. ANCHOR TO CONCRETE OR MASONRY WITH EXPANSION ANCHORS. 0 REMOVE EXISTING LIBRARY SHELVING WITH CARE AND TURN OVER TO OWNER. 0 PROVIDE ROOM SIGNAGE TO MATCH EXISTING BUILDING SIGNAGE. SIGN TEXT AS DIRECTED. NOTE: REFER TO DRAWING A4 FOR DETAILS AND SCHEDULES AS APPLICABLE. HVAC & SPRINKLER SYSTEM CONSTRUCTION KEYED NOTES: 0 PROVIDE HIGH SIDEWALL CHILLED WATER FAN COIL UNIT. REFER TO DRAWING M2. REFER TO DRAWING M4 FOR UNIT SCHEDULE. 0 PROVIDE CONNECTION TO EXISTING BRANCH LINE. PROVIDE ADDITIONAL SPRINKLER COVERAGE. 0 PROVIDE DRY WALL SPRINKLER COVERAGE FOR ITR -3A ROOM. COORDINATE SPRINKLER LOCATION WITH LIGHTS, PANELS, CABLE TRAYS AND TELECOMUNICATION EQUIPMENT LOCATIONS. NOTE: REFER TO DRAWING M4 FOR DETAILS AND SCHEDULES AS APPLICABLE. ELECTRICAL CONSTRUCTION KEYED NOTES: E1 REMOVE EX. LIGHT FIXTURE AND WIRING. PROVIDE END TERMINATION UNIT FOR LIGHTING TRACK. E2 PROVIDE TGB PER DETAIL ON DRAWING E4. E3 PROVIDE NEW DUPLEX RECEPTACLE AT 24" AFF. E4 #1. PROVIDE 20A DUPLEX RECEPTACLE AT 24" AFF. FEED FROM EX. ELECRICAL PANEL IN ADJACENT ROOM, SPARE CIRCUIT PROVIDE TWO 20A DUPLEX RECEPTACLES IN COMMON BOX, EACH FED FROM SEPARATE CIRCUIT. MOUNT AT 24" AFF. PROVIDE NEW LIGHT SWITCH, CONNECT TO EX. LIGHTING BRANCH CIRCUIT IN ROOM. PROVIDE NEW LIGHT FIXTURE PER SCHEDULE ON DRAWING E4. PROVIDE EM FIXTURE, CONNECT TO UNSWITCHED LEG OF LIGHTING BRANCH CIRCUIT THAT FEEDS THE ROOM. EXTEND EXISTING FIRE ALARM CIRCUIT TO NEW SMOKE DETECTOR. PROVIDE ALL SHUT DOWNS, TIE—INS AND VERIFICATIONS OF EXISTING ADDRESSABLE SYSTEM TO ENSURE THAT THE FACP CAN SUPPORT NEW DEVICES. CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR TESTING, REPROGRAMMING AND MODIFICATION TO EXISTING FIRE ALARM PANEL AND REMOTE ANNUNCIATORS TO SHOW NEW DEVICE(S). RELOCATE EX. LIGHT SWITCH ON BOOK STACK. PROVIDE CIRCUIT FOR ACCESS CONTROL SYSTEM READER INTERFACE MODULE AND ASSOCIATED DOOR LOCK. DURING CONSTRUCTION, WHILE PARTICULATE IS BEING GENERATED, THE SAMPLING PORTS OF THE VESDA SYSTEM SHALL BE TEMPORARILY COVERED. RECTIFICATION OF TROUBLE SIGNALS GENERATED BY THE VESDA SYSTEM SHALL BE THE CONTRACTORS RESPONSIBILITY. E5 E6 E7 E9 NOTE: REFER TO DRAWING E4 FOR DETAILS AND SCHEDULES AS APPLICABLE. GENERAL NOTES: A. REFER TO DRAWING AMEP—GEN. B. REFER TO DRAWING M2 FOR CONTINUATION AND ADDITIONAL COORDINATION REQUIREMENTS. C. REFER TO DRAWING T3 -3A FOR ADDITIONAL COORDINATION REQUIREMENTS. KEY PLAN I Pwl. nrner, 411114/ 115 METRO PHONE: ARCHI-TECHNOLOGY, LLC www.archi-technology.com PARK ROCHESTER, NY 14623 585.424.1952 Fax: 585.424.4239 EARDSLEY DESIGN ASSOCIATES Architecture, Engineering, Landscape Architecture, P.C. Ph 315.47E-698® 5789 Widewaters Parkway Fax 315.472.3523 Dewitt, New York 13214 E-mail BBA@Reardsley.eam OLIN LIBRARY - 2047 ITHACA, NY CLIENT: ®fit NETWORK Cornell University PROJECT �IIpV . 4 CONNECTIVITY rd ' L 9. CD 06/29/12 CONSTRUCTION DOCUMENTS 100 DD 05/17/12 100% DD SUBMISSION 50 DD 50% DD SUBMISSION 20 SD 10/07/11 20% SD SUBMISSION PSD 08/26/11 PRELIMINARY SD MARK DATE DESCRIPTION CONSTRUCTION DOCUMENTS ISSUE DATE: 06/29/12 �� q- OA�OFS1ONP\(('. (EDF NEI, k y ,SND N. CUA 0,efs F X6315'' AT PROJECT NO: 11103-2047 OWNER PROJECT NO: 754 DRAWN BY: PKB CHECKED BY: JLB PROJECT MANAGER: GHS SHEET TITLE: ITR -3A PARTIAL PLANS AND KEYNOTES AMEP-3A L d a 3 W F- D J 0 ‘.. Cl: MTR—SBA EX. PANEL EMPP EX. SECONDARY SWITCHGEAR SUB -BASEMENT - AMEP AREAS OF WORK Scale: 1/40" = 0 40' 80' THIRD FLOOR - AMEP AREAS OF WORK Scale: 1/40" = 1'-0" SEVENTH FLOOR - AMEP AREAS OF WORK Scale: 1/40" = 1'-0" BASEMENT - AMEP AREAS OF WORK Scale: 1/40" = 1'-0" FOURTH FLOOR - AMEP AREAS OF WORK Scale: 1/40" = 1'-0" 8POSA 8POUA BPOUG BPOUE a 8POU8 d .OF POUR1 80' 8POSC RODF min 111 POEE 70058 BPOUC EIGHTH FLOOR - AMEP AREAS OF WORK Scale: 1/40" = 1'-0" H H II H lE H FIRST FLOOR - AMEP AREAS OF WORK Scale: 1/40" = 1'-0" FIFTH FLOOR - AMEP AREAS OF WORK Scale: 1/40" = 1'-0" J+\PROJECTS—Ithaca\2011\11103 CORNELL — NCP\Olin Library 2047\CAD\11103-2047--Tl—SZ.dwg SCALES ON THIS DRAWING ACCURATE WHEN PLOTTED TO: ARCH El (30X42 IN.) SECOND FLOOR - AMEP AREAS OF WORK Scale: 1/40" = 1'-0" SIXTH FLOOR - AMEP AREAS OF WORK Scale: 1/40" = 1'-0" insirEllem AW 115 METRO PHONE: ARCHIMTECHNOLOGY, LLC www.archi-technology.com PARK ROCHESTER, NY 14623 585.424.1952 Fax: 585.424.4239 OLIN LIBRARY - 2047 ITHACA, NY CLIENT: NETWORK 4' CONNECTIVITY Cornell University PROJECT _ T r} CD 06/29/12 CONSTRUCTION RUCTION DOCUMENTS 100 DD 05/17/12 100% DD SUBMISSION 50 DD 50% DD SUBMISSION 20 SD 20% SD SUBMISSION PSD 08/05/11 PRELIMINARY SD MARK DATE DESCRIPTION CONSTRUCTION DOCUMENTS ISSUE DATE: 06/29/12 ,OF NEWY coy ow) N.CU�°'F' k- ` <b_ 063153 g `R4F: StONP� AT PROJECT NO: 1.1103-2047 OWNER PROJECT NO: 754 DRAWN BY: PKB CHECKED BY: JLB PROJECT MANAGER: GHS SHEET TITLE: AMEP-AREAS OF WORK PLOT BY: pbarrie PLOT DATE: June 28, 2012 NET •RK CSNNECTIVITY P - 207 ORRILL HAL 2001 JBRARY 0 7A I11i(IIIII URIS LIBRARY 2010 PAVED PARKING SAGE CHAPEL 2005 PUS ST 2088 WILLARD STRAIGHT HALL 2020 J:\PROJECTS-Ithaca\2011\11103 CORNELL - NCP\Olin Library 2047\CAD\11103-2047--T-COVER.dwg DRAWING INDEX DRAWING DESCRIPTION T -COVER DRAWING INDEX AND PROJECT SITE PLAN T -GEN STANDARD SYMBOLS, NOTES, ABBREVIATIONS (T -SERIES) T1 T1 -SZ TR SERVING ZONES, PLAN VIEWS AND BLDG. SEC I ON VIEW Ti -PL PATHWAYS LOGICAL RISER DIAGRAMS Ti -CL COPPER LOGICAL RISER DIAGRAMS T1 -FL FIBER LOGICAL RISER DIAGRAMS T2 T2-SB.CA_CP SUB -BASEMENT PATHWAYS AND CABLING T2-B.CA CP BASEMENT PATHWAYS AND CABLING T2-B.D.CA_CP BASEMENT PATHWAYS DEMOLITION T2-1.CA_CP FIRST FLOOR PATHWAYS AND CABLING T2-2.CA_CP SECOND FLOOR PATHWAYS AND CABLING T2-3.CA_CP THIRD FLOOR PATHWAYS AND CABLING T2-4.CA_CP FOURTH FLOOR PATHWAYS AND CABLING r C'A tjl T 2-.;J.CA_C /'A .li TI 1!"� f 1h ! H rLOOF rH I I IV V/-\ 1 S HIV' CJA3L1IVV f"'T t 1 1 [-1 r pF r r AT1 11A '.Pf A IT'D T2-6.CA_CP SIXTH FLOOR PATHWAYS AND CABLING T2-7.CA_CP SEVENTH FLOOR PATHWAYS AND CABLING T2-8.CA_CP EIGHTH FLOOR PATHWAYS AND CABLING T3 T3 -SBA MTR-SBA ENLARGED PLANS AND ELEVATIONS T3 -3A ITR -3A ENLARGED PLANS AND ELEVATIONS T3 -6A ITR -6A ENLARGED PLANS AND ELEVATIONS T3-SBEF SUB -BASEMENT ENTRANCE FACILITY AMEP AMEP-GEN GENERAL NOTES, SYMBOLS AND ABBREVIATIONS (AMEP SERIES) T1-AMEP AMEP-AREAS OF WORK AMEP-SBA MTR-SBA PARTIAL PLANS AND KEYNOTES AMEP-3A ITR -3A PARTIAL PLANS AND KEYNOTES AMEP-6A ITR -6A PARTIAL PLANS AND KEYNOTES A4 ARCHITECTURAL DETAILS M4 MECHANICAL DETAILS E4 ELECTRICAL DETAILS M-2 AMEP ENLARGED PLANS -MECHANICAL SCALES ON THIS DRAWING ACCURATE WHEN PLOTTED TO: ARCH El (30X42 IN.) J ECT Fire F410 46140 115 METRO PHONE: ARCHITECHNOLOGY, LLC www.archi-technology.com PARK ROCHESTER, NY 14623 585.424.1952 Fax: 585.424.4239 r N. I 0 N >-- Q >-- cY Z CO Q Z Q i 0 �..-� V) aC W D J _1 W Z 0 U CLIENT: University PROJECT I(g,• _ • 4Cornell NETWORK CONNECTIVITY CD 06/29/12 CONSTRUCTION DOCUMENTS 100 DD 05/17/12 100% DD SUBMISSION 50 DD 03/23/12 50% DD SUBMISSION 20 SD 10/07/11 20% SD SUBMISSION PSD 08/26/11 PRELIMINARY SD NARK DATE DESCRIPTION CONSTRUCTION DOCUMENTS ISSUE DATE: 06/29/ 1 2 x Y 14 g. t 4` i' � N AT PROJECT NO: 11103-2047 OWNER PROJECT NO: 754 DRAWN BY: PKB CHECKED BY: JLB PROJECT MANAGER: GHS SHEET TITLE: DRAWING INDEX AND PROJECT SITE PLAN T -COVER GENERAL PROJECT NOTES A. REFER TO A-, E-, AND M -SERIES DRAWINGS FOR AMEP SYMBOLS AND ABBREVIATIONS. B. REFER TO SPECIFICATION (SPEC) SECTION: DIVISION (DIV) 01 WORK UNDER CONTRACT. C. THIS INFORMATION REPRESENTS EXISTING CONDITIONS BASED ON ORIGINAL DRAWINGS AND OBSERVED SITE CONDITIONS. THE CONTRACTOR SHALL FIELD VERIFY EXACT ROUTING, DIMENSIONS AND QUANTITIES. THE CONTRACTOR SHALL DISCONNECT, REMOVE AND RECYCLE/DISPOSE OF ALL EXISTING CABLING AND DEVICES THAT ARE NOT SCHEDULED FOR REUSE. D. RACEWAY, CONDUIT, CABLING AND ELECTRICAL/MECHANICAL PATHS ARE SHOWN FOR REFERENCE ONLY. EACH CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS AND SHALL DETERMINE BEST PATHS FOR NEW INSTALLATION THAT WILL CAUSE THE LEAST DISTURBANCE TO OCCUPIED SURROUNDINGS AND BUILDING OPERATIONS (INCLUDING EVENING CLASSES). E. EACH CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND PERFORM EXPLORATORY INVESTIGATIONS FOR CONCEALED CONDITIONS AS REQUIRED. EQUIPMENT LOCATIONS AND ROUTES ARE APPROXIMATE AND MINOR ADJUSTMENTS TO THE INSTALLATION WILL BE REQUIRED TO AVOID CONFLICTS WITH EXISTING EQUIPMENT, APPARATUS, AND OCCUPANTS' FURNITURE AND PERSONAL BELONGINGS. F. ALL DRAWINGS ARE SCHEMATIC IN NATURE. THE CONTRACTOR SHALL PROVIDE OFFSETS, ENTRANCE END FITTINGS, RADIUS FITTINGS, HANGERS, ANCHORS, SUPPORT, WIRING AND ACCESSORIES NECESSARY FOR A COMPLETE, OPERATIONAL INSTALLATION. G. IT IS THE RESPONSIBILITY OF EACH CONTRACTOR TO COORDINATE WORK SHOWN ON THEIR CONTRACT DOCUMENTS WITH THE WORK OF OTHER TRADES PRIOR TO SCHEDULING, SHUTDOWN, DEMOLITION, FABRICATION OR INSTALLATION OF ANY WORK OR EQUIPMENT. EQUIPMENT OR DEVICES THAT CANNOT CHANGE LOCATION SHALL TAKE PRECEDENCE OVER THOSE THAT CAN CHANGE LOCATION. H. ALL TRADES AND CONTRACTS ARE RESPONSIBLE TO REVIEW SITE-SPECIFIC CLASSROOM SCHEDULING (DAILY AND WEEKLY), SPECIAL EVENTS/CONFERENCES, UNIVERSITY ACADEMIC CALENDARS, UNIVERSITY CLOSING AND HOLIDAYS. FACTOR WORK SCHEDULING AND MANPOWER LOADING IN SUCH A WAY SO AS TO MINIMIZE STUDENT AND STAFF DISRUPTIONS. I. PROVIDE SCHEDULES AND ONGOING PROGRESS REPORT SUBMITTALS FOR DEMOLITION AND NEW CONSTRUCTION AS CALLED FOR. REFER TO DIV 01 SUBMITTAL PROCEDURES, AND DIV 01 - PROJECT MEETINGS SPECIFICATION SECTIONS. J. ALL TRADES AND CONTRACTS ARE RESPONSIBLE FOR THEIR OWN DEMOLITION, TEMPORARY FACILITIES, SAFETY PROGRAMS, PATCHING, PAINTING, FIRESTOP, TRASH REMOVAL/DISPOSAL, ROUTINE CLEANING, SPECIAL TELECOMMUNICATION ROOM CLEANING AND FINAL CLEANING, AS CALLED FOR. REFER TO SPEC SECTIONS IN DIV 01 THROUGH AND INCLUDING DIV 09 AS APPLICABLE. K. WHEN DRY CUTTING PLASTER, GY?SUM, CONCRETE MASONRY UNITS OR PLYWOOD - PROVIDE APPROPRIATE DUST AND NOISE CONTROL TEMPORARY PARTITIONS AND MAINTAIN EGRESS AND FIRE ALARM SYSTEM OPERATION. PROVIDE ZIP -WALL DUST BARRIERS OR OTHER APPROPRIATE PROTECTION TO LOCALIZE CLEANUP AND MINIMIZE THE EXTENTS OF FIRE ALARM SHUTDOWNS AND PREVENT FALSE FIRE ALARMS FOR SMALL SCALE CUTTING AND DEMOLITION. WHERE GENERAL CONSTRUCTION WILL CREATE DUST AND DEBRIS, THE CONTRACTOR SHALL PROVIDE PROTECTIVE COVERING FOR FURNITURE, FURNISHINGS AND EQUIPMENT. . "ERL" ADJACENT TO A DEVICE, FIXTURE OR PIECE OF EQUIPMENT INDICATES AN EXISTING ITEM TO BE RELOCATED. DISCONNECT AND REMOVE THE ITEM. REMOVE ALL UNNECESSARY RACEWAY AND WIRING. REINSTALL AND RECONNECT ITEM AS REQUIRED. M. "ETR" ADJACENT TO A DEVICE, FIXTURE OR PIECE OF EQUIPMENT INDICATES EXISTING ITEM TO REMAIN. MAINTAIN EXISTING CONNECTIONS TO EQUIPMENT UNLESS NOTED OTHERWISE. N. PROVIDE QUALIFIED TRADES PERSON OR CONTRACTOR TO RESTORE FINISHED WALLS, CEILING AND FLOORS TO ORIGINAL CONDITION AS CALLED FOR IN DIV 01 - CUTTING AND PATCHING. 0. WHERE GENERAL CONSTRUCTION WILL CREATE DUST AND POTENTIAL FALSE SMOKE DETECTOR SIGNALS, THE CONTRACTOR SHALL COORDINATE FIRE ALARM SYSTEM SHUTDOWNS WITH CORNELL EH&S. VISIT SITE PRIOR TO SUBMITTING WRITTEN SHUTDOWN REPORT - TO CONFIRM EXISTING SMOKE DETECTOR LOCATION AND OWNERS' DEVICE/ZONE ADDRESS WITH RESPECT TO LOOK -AHEAD WORK SCHEDULE. REFER TO EXISTING FIRE ALARM DEVICE SCHEDULE, AS APPLICABLE. FALSE FIRE ALARMS CAUSED BY CONSTRUCTION DUST WILL NOT BE TOLERATED. CONTRACTORS ARE RESPONSIBLE TO PAY FOR ANY FINES IMPOSED BY ITHACA/CAYUGA HEIGHTS FIRE DEPARTMENT FOR UNNECESSARY FALSE FIRE ALARMS. P. RESTORE AND MAINTAIN AREA FIRE RESISTANCE RATING OF FLOOR AND WALLS. RESTORE AND MAINTAIN AREA SMOKE BARRIERS RATING OF WALLS AND SOFFITS WITH SIMILAR MATERIALS AS CALLED FOR IN DIV 01 - CUTTING AND PATCHING. ALSO REFER TO SPEC SECTION DIV 07 - PENETRATION FIRESTOPPING. Q. FIRESTOP ALL NEW AND EXISTING TELECOM WALL PENETRATIONS AND CONDUIT SLEEVES TO MAINTAIN AREA FIRE RESISTANCE RATING. R. MAINTAIN EXISTING SERVICES AT ALL TIMES DURING NORMAL BUILDING OPERATIONS. PROVIDE TEMPORARY SERVICES AS REQUIRED, OR AS DIRECTED. EXISTING DATA/COMMUNICATIONS CABLE AND OUTLETS SHALL REMAIN DURING THE INSTALLATION OF NEW CABLING AND DEVICES TO MINIMIZE DOWN TIME. COORDINATE CUTOVER TO NEW SYSTEM WITH PROJECT MANAGER. REFER TO SPEC SECTION 27 - COMMISSIONING. . ALL TRADES AND CONTRACTS SHALL REPAIR DAMAGED CEILINGS (ANY TYPE), REPLACE LAY -IN CEILING TILES AND GRID WHERE NOTCHED OR DAMAGED FOR EXISTING REMOVALS OR NEW INSTALLATIONS, AS CALLED FOR IN DIV 01 - CUTTING AND PATCHING. REFER TO EXISTING CEILING SCHEDULE ON NEW WORK T2 DRAWINGS. T. PROVIDE BLANK COVERS, FIRE SEAL, CUTTING, AND PATCHING AS REQUIRED TO REPAIR HOLES, UNPAINTED AREAS, OR OTHER PHYSICAL DEFECTS CAUSED BY THE REMOVAL AND INSTALLATION OF EQUIPMENT AND DEVICES. U. PROVIDE ELECTRONIC SUBMITTAL(S) ON ACTUAL PRODUCTS USED VIA PROJECT WEBSITE. INCLUDE COPY OF APPROVED SUBMITTAL WITH CLOSE-OUT DOCUMENTS (IN HARD COPY 0/M MANUAL), REFER TO SECTIONS: 01 33 00 - SUBMITTALS; 01 78 39 - RECORD DOCUMENTS; AND 01 77 00 - PROJECT CLOSEOUT AS APPLICABLE. V. DIVISION 27 CONTRACTOR SCOPE: FOR ALL EXISTING SR -4 RACEWAY, THOROUGHLY WIPE DIRT AND DUST FREE FROM ALL REUSED EXISTING SR -4 SERIES RACEWAYS, REMOVE METAL FILINGS FROM INSIDE RACEWAYS AT ALL CONDUIT CONNECTIONS. WHEN RACEWAY IS SHARED WITH ELECTRIC, PROVIDE/MAINTAIN METALLIC SEPARATION BARRIERS, PER NEC CODE. AT LOCATIONS WITH EXISTING ROUND MODULAR OR 4 -PRONG OUTLETS, REMOVE/REPLACE EXISTING SR -4 COVER WITH NEW DEVICE COVER TO CLOSE THE OPEN HOLE (AND PRIME AND PAINT TO MATCH). AT LOCATIONS WITH EXISTING OPENINGS IN EXISTING SR -4, REMOVE/REPLACE EXISTING SR -4 COVER WITH NEW DEVICE COVER TO CLOSE THE OPEN HOLE (AND PRIME AND PAINT TO MATCH). REPLACE EXISTING BENT/DAMAGED OR MISSING SR -4 COVERS (ASSUME 10' OF NEW COVER FOR EVERY 150' OF EXISTING RACEWAY, EVEN IF NOT SPECIFICALLY INDICATED ON THE DRAWINGS). W. CUTOVER OF ACTIVE BACKBONE SERVICES TO BE PERFORMED BY CIT FIELD SERVICES UNLESS OTHERWISE NOTED. END OF NOTES GENERAL REMOVAL NOTES A. AFTER VOICE/DATA CUTOVER, REMOVE EXISTING SURFACE MOUNTED COMMUNICATION OUTLETS AND ASSOCIATED CABLING UNLESS OTHERWISE NOTED TO REMAIN. PATCH AND PAINT AS CALLED FOR. PROVIDE BLANK COVER PLATE TO MATCH EXISTING AS REQUIRED. . AFTER VOICE/DATA CUTOVER, AT EXISTING RECESSED COMMUNICATION OUTLETS PROVIDE BLANK COVER PLATE. REMOVE ALL ASSOCIATED CABLING IN ITS ENTIRETY. PROVIDE BLANK COVER PLATE ON ALL EXISTING UNUSED OPENINGS AS WELL. C WHEN EXISTING -. SU.R FACT RACEWAY IS CALLED F TO REMAIN FOR REUSE, EXISTING REMOVE TING COMMUNICATIONS FACEPLATES AND OLD O S CABLING IN THEIR ENTIRETY, AFTER VOICE/DATA CUTOVER, AS CALLED FOR. PROVIDE BLANK PLATE OR REPLACEMENT COVER SECTIONS TO CONCEAL OPENINGS. . RECYCLE REMOVED METALLIC COMPONENTS, RACEWAYS AND CABLING TO THE GREATEST EXTENT POSSIBLE. COORDINATE DUMPSTER LOCATION IN ADVANCE WITH THE PROJECT MANAGER. . AFTER VOICE/DATA CUTOVER, REMOVE EXISTING CABLING BACK TO SOURCE. REMOVE ALL ASSOCIATED ANCHORS, TERMINAL BLOCKS, AND SPLICE CASES. COORDINATE THE CUTOVER OF ALL REMAINING SYSTEMS WITH THE PROJECT MANAGER. AFTER VOCE/DATA CUTOVER, DISCONNECT AND REMOVE TERMINAL BLOCKS, ENCLOSURE, PLYWOOD BACKBOARD, AND .' L ASSOCIATED CABLING IN THEIR ENTIRETY. PRIOR TO REMOVAL, THE CONTRACTOR SHALL TEST ALL PAIRS FOR SERVICE. COORDINATE THE CUTOVER OF ALL REMAINING SYSTEMS WITH THE PROJECT MANAGER. PATCH AND PAINT WALLS TO MATCH EXISTING AREA IN CORRIDORS AND OFFICE AREAS. G. DISCONNECT AND REMOVE ALL EXISTING DEVICES/WIRING SHOWN FOR REMOVAL, BACK TO SOURCE. MAKE ALL CONNECTIONS NECESSARY TO MAINTAIN EXISTING SYSTEMS WHERE PARTIAL DEMOLITION IS REQUIRED DUE TO SCHEDULING. H. REPLACE CEILING TILES AND CEILING GRID, TO MATCH EXISTING, WHERE NOTCHED FOR EXISTING CONDUITS AND RACEWAYS THAT ARE CALLED TO BE REMOVED. END OF NOTES GENERAL NEW WORK NOTES A. CABLE TRAY, CONDUIT AND RACEWAY ROUTING SHOWN IS DIAGRAMMATIC ONLY. CONTRACTOR TO FIELD VERIFY EXISTING CONDITIONS AND ROUTE PATHWAYS TO AVOID MECHANICAL AND STRUCTURAL CONFLICTS. NOT ALL REQUIRED JUNCTION BOXES AND OFFSETS ARE SHOWN, PROVIDE OFFSETS AND PULLBOXES AS REQUIRED. B. CONTRACTOR SHALL REMOVE AND REPLACE SPLINE CEILINGS TO ACCESS WORK AREAS AS INDICATED ON THE T2-x.CP_CA DRAWINGS. CONTRACTOR SHALL ALSO PROVIDE ACCESS PANELS AT ALL NEW PULLBOXES INSTALLED IN SPLINE CEILINGS. C. WHERE EXISTING PATHWAYS ARE TO REMAIN AND BE REUSED, THE CONTRACTOR SHALL RE -SUPPORT AND PROVIDE RADIUS FITTINGS AS NEEDED TO ENSURE COMPLIANCE WITH SPECIFICATIONS AND UNIVERSITY STANDARDS. D. A PULLBOX SHALL BE INSTALLED FOR RACEWAYS, SIZED AS INDICATED, IN RACEWAY INCREMENTS OF 100 FEET, AND WHEN THE ACCUMULATIVE BEND RADII IS EQUIVALENT TO 180 DEGREES. INSTALL CONDUITS THROUGH PULLBOXES ONLY AS DEPICTED ON STANDARD DETAILS, AND T2-x.CA_CP SERIES DRAWINGS. E. LOCATIONS OF PULLBOXES SHOWN ARE APPROXIMATE - PULLBOXES SHALL BE LOCATED IN AN AREA THAT IS READILY ACCESSIBLE. FIELD VERIFY THE EXACT LOCATIONS. F. THE USE OF CONDUIT BODIES (SMART LB'S) THAT HAVE BUILT-IN BEND RADIUS CONTROL DESIGNED FOR TELECOMMUNICATIONS APPLICATIONS ARE PERMITTED IN ALL COPPER, FIBER AND UTP RISER CONDUITS USED FOR TELECOMMUNICATIONS PATHWAYS. G. THE PULLING TENSION OF UTP CABLES SHALL NOT EXCEED 25 LBS PER CABLE. PROVIDE ADDITIONAL INSTALLERS AT CORNERS AND UTILIZE APPROVED LUBRICANT AS REQUIRED. H. COORDINATE THE ROUTING OF ALL PATHWAYS WITH EXISTING DUCT WORK, PIPING, ELECTRICAL CONDUITS, AND OTHER EXISTING OBSTRUCTIONS. I. PROVIDE ALL REQUIRED OFFSETS, FABRICATION AND FITTINGS REQUIRED FOR THE INSTALLATION OF CABLE TRAY, CONDUIT, SURFACE RACEWAY, AND CABLE RUNWAY. J. CABLE TRAY AND CONDUIT SHALL BE INSTALLED CONCEALED UNLESS OTHERWISE NOTED. K. PAINT EXPOSED CONDUITS, SUPPORTS, PULLBOXES, ETC. REFER TO DIV 09 - INTERIOR PAINTING. END OF NOTES GENERAL DRAWING NOTES -EXISTING CONDITIONS/REMOVALS- A. ITEMS SHOWN GRAYSCALE ARE EXISTING TO REMAIN UNLESS SPECIFIED OTHERWISE. B. ITEMS SHOWN DASHED -BOLD ARE TO BE REMOVED UNLESS SPECIFIED OTHERWISE. C. EXISTING CONDITIONS HAVE BEEN DOCUMENTED TO THE EXTENT POSSIBLE AT TIME OF SURVEY. TRUST BUT VERIFY ALL EXISTING CONDITIONS ARE AS INDICATED ON "T" SERIES DRAWINGS. REDLINE ON RECORD DRAWINGS ANY DEVIATIONS. END OF NOTES GENERAL DRAWING NOTES -HORIZONTAL CABLING - A. ITEMS SHOWN BOLD ARE NEW WORK UNLESS SPECIFIED OTHERWISE. B. ITEMS SHOWN IN GRAYSCALE ARE EXISTING TO REMAIN UNLESS SPECIFIED OTHERWISE. C. PROVIDE MANUFACTURER ENGINEERED SOLUTION FOR SMOKE AND FIRE STOPS. D. REFER TO DRAWINGS T1 -CL, T1 -FL, T3-xx, AND SPECIFICATIONS 27 13 00, 27 15 00, 27 05 00, 27 05 53 FOR ADDITIONAL REQUIREMENTS. E. PROVIDE CAT 6A CABLING FOR ALL OUTLETS LOCATIONS WITH A WAP OUTLET DESCRIPTOR. PROVIDE CAT 6 CABLING FOR ALL OTHER OUTLET LOCATIONS WITH NEW CABLING INDICATED. F. ALL NEW CAT 6 AND CAT 6A CABLING SHALL BE NON PLENUM CMR RATED. G. BACKBONE CABLING AND HORIZONTAL CABLING SHALL NOT OCCUPY THE SAME CONDUIT / CABLE TRAY UNLESS APPROVED BY OWNER. END OF NOTES GENERAL DRAWING NOTES -PATHWAYS- A. ITEMS SHOWN BOLD ARE NEW WORK UNLESS SPECIFIED OTHERWISE. B. ITEMS SHOWN IN GRAYSCALE ARE EXISTING TO REMAIN UNLESS SPECIFIED OTHERWISE. C. REFER TO DRAWINGS T2-x.CA_CP AND T1 -PL FOR HORIZONTAL PATHWAYS. D. REFER TO A-, M-, E -SERIES DRAWINGS FOR ADDITIONAL REQUIREMENTS. E. REFER TO T1 -FL DRAWING FOR ADDITIONAL REQUIREMENTS. F. PATCH/FIRESTOP ALL EXISTING AND NEW CONDUIT CABLE PENETRATIONS IN CORRIDOR WALLS. G. REMOVE LIGHTS AS REQUIRED TO ACCESS ABOVE CEILING LOCATIONS. REPORT ANY EXISTING DAMAGED OR NON -OPERATIONAL LIGHTS TO OWNER'S REPRESENTATIVE PRIOR TO LIGHT REMOVAL. H. EMT TO BE USED IN ALL NEW CONDUIT INSTALLATIONS IF POSSIBLE. FLEX CONDUIT TO BE USED AS LAST RESORT IF FIELD CONDITIONS PREVENT USE OF EMT. IF FLEX CONDUIT IS TO BE USED, IT SHALL BE INCREASED TO ONE TRADE SIZE LARGER THAN REQUIRED FOR EMT. I. PROVIDE BUSHINGS FOR ALL CONDUIT ENDS INSIDE EXISTING & NEW PULLBOXES. J. RE -CONNECT ANY EXISTING CONDUIT BEING REUSED THAT HAS SEPARATED FROM FITTING. K. PERMANENT LABEL NEAT AND LEGIBLE, ALL NEW AND EXISTING PULLBOX COVERS WITH "COMMUNICATIONS ONLY". L. ALL NEW RACEWAY TO BE METALLIC UNLESS OTHERWISE NOTED. M. PROVIDE SPACE SAVER CONDUIT CONNECTORS IN NEW OUTLET BOXES, RACEWAYS AND PULLBOXES. REFER TO SECTION 27 05 28. N. WHERE INDICATED ON THE DRAWINGS, PAINT EXPOSED CONDUITS, SUPPORTS, PULLBOXES, ETC. WHERE INSTALLED IN FINISHED (PUBLIC) NON-MECHANICAL AREAS. REFER TO DIV 09, INTERIOR PAINTING. 0. ALL OUTLETS THAT ARE CALLED TO BE RECESS MOUNTED SHOULD BE IN A DOUBLE GANG BOX. ALL OUTLETS THAT ARE FED VIA SR -2 RACEWAY SHOULD BE ASSUMED TO BE SINGLE GANG SURFACE MOUNT OUTLET BOXES UNLESS OTHERWISE NOTED. P FOR AI I EMERGENCY ANn WAIL PHONE LOCATIONS THAT CALL FOR SURFACE RACEWAYS ASSUME SR -7 AND ASSOCIATED FITTINGS. Q. ALL EXISTING AND NEW PATHWAYS THAT ARE 2" AND LARGER, AND LONGER THAN 10' SHALL BE BONDED. R. ALL CABLE TRAYS SHALL BE ELECTRICALLY CONTINUOUS. COMMUNICATIONS PATHWAYS THAT END IN CLOSE PROXIMITY TO THE CABLE TRAY SHALL BE BONDED TO THE CABLE TRAY. S. ALL PATHWAYS TERMINATING IN THE MTR\ITR SHALL BE BONDED TO THE TMGB\TGB. T. CABLES SUPPORTED IN J HOOKS SHALL FOLLOW THE J HOOK MANUFACTURERS REQUIREMENTS FOR MOUNTING, SPACING, AND FILL CAPACITY. END OF NOTES ACCESS CONTROL SYMBOLS LEGEND CRL CARD READER LOCK El DOOR CONTACT (POSITION SWITCH) SRI SINGLE INPUT READER INTERFACE MODULE El DUAL INPUT READER INTERFACE MODULE TSC INTELLIGENT SYSTEM CONTROLLER (CONTROL PANEL) PATHWAY SCHEDULE - NEW WORK CABLE FILL BASED ON CABLE OD G = 0.24 DESIGNATION DESCRIPTION MANUFACTURER PART NO. APPROXIMATE OUTSIDE DIMENSION APPROXIMATE INSIDE DIMENSION CABLE FILL CAPACITY* MIN. BEND RADIUS .75" C = CONDUIT SEE SPEC. SECTION 27 05 28 .75" DIA. 4 4.5" 1" C 1" DIA. 7 6" 1.25" C 1.25" DIA. 13 7.5" 1.5" C 1.5" DIA. 18 9" 2" C 2" DIA. 29 12" 2.5" C 2.5" DIA. 51 25" 3" C 3" DIA. 78 30" 4" C 4" DIA. 130 40" ETREQUIPMENT SR -1 NOT USED ELEVATOR PHONE SR -2 ** SURFACE RACEWAY SEE SPEC. SECTION 27 05 28 2400 SERIES SEE SPEC. SECTION 27 05 28 12 GWB SR -3 ** SURFACE RACEWAY 3000 SERIES 32 SR -4 ** SURFACE RACEWAY 4000 SERIES 63 SR -4D ** SURFACE RACEWAY (DIVIDED) 4000D SERIES 30 SR -5 ** SURFACE RACEWAY 5400 SERIES 32 SR -6 ** SURFACE RACEWAY 6000 SERIES 140 SR -6D ** SURFACE RACEWAY (DIVIDED) 6000D SERIES 63 SR -7 SURFACE RACEWAY 700 SERIES 2 SINGLE -MODE OPTICAL FIBER CT -A ENCLOSED TRAYCT-E SEE SPEC. SECTION 27 05 28 4"x6" 211 TELECOMMUNICATION GROUND BUS BAR CT -B TELECOMMUNICATIONS MAIN GROUNDING BAR 2"x12" 211 CT -C TELECOMMUNICATIONS ROOM 2"x18" 316 CT -D UNLESS NOTED OTHERWISE 2"x24" 419 UTP SEE SPEC. SECTION 27 05 28 4"x12" 419 CT -F 6"x12" 632 CT -G 4"x24" 844 CT -H 6"x6" 318 CT -I WIRE DUCT NOT USED 6"x6" 318 CT -J 4"x6" 212 CT -K 4"X9" 318 NOTES: 0 40% MAXIMUM FILL FOR CATEGORY 6 INDICATED (PER TIA / EIA 569-A). - CAT6A CABLING HAS AN OD OF 0.285. - REDUCE FILL RATIO BY 6% FOR EACH 90° BEND - ENSURE THAT FILL RATIOS ARE NOT EXCEEDED 3/4" CONDUIT SHALL ONLY BE ALLOWED AS SPECIFICALLY NOTED ON DRAWINGS. ** REDUCE CAPACITY BY 50% FOR THE FOLLOWING CONDITIONS: - WHEN CONNECTORS ARE MOUNTED WITHIN RACEWAY - WHEN NON -RADIUS FITTINGS RESTRICT CROSS-SECTIONAL AREA - WHEN RACEWAY IS DIVIDED AND SHARED WITH ELECTRIC ALTER EXISTING SURFACE RACEWAY TO PROVIDE AT LEAST TWO 16" SECTIONS OF REMOVABLE COVERS TO ALLOW CABLE ROUGH -IN WITHOUT CONFLICT WITH EXISTING FURNITURE CONFIGURATIONS. ALSO REFER TO GENERAL NOTE "Z" ON T -GEN DRAWING FOR ADDITIONAL SCOPE FOR SURFACE RACEWAYS. WHERE REQUIRED BY RACEWAY CAPACITY, OR AS DIRECTED, PROVIDE SURFACE MOUNT EXTENSION BOX ON EXISTING RACEWAY OPENING TO PROVIDE ADEQUATE CAPACITY AND BEND RADIUS. ALSO REFER TO RACEWAY DERATING REQUIREMENTS AT LEFT. WHERE REQUIRED BY RACEWAY CAPACITY, OR AS DIRECTED, PROVIDE RETROFIT ENTRANCE END FI I I ING OR ALTER EXISTING BACKFED CONDUIT WITH A NEW SPACE SAVER CONNECTOR TO PROVIDE ADEQUATE CAPACITY AND BEND RADIUS FOR NEW CABLING. ALSO REFER TO RACEWAY DERATING REQUIREMENTS AT LEFT. FIELD VERIFY EXISTING CONDITIONS AND PROPOSE ALTERATIONS THAT MINIMIZE SERVICE DISRUPTION DURATION. PROVIDE ALL TEMPORARY PROVISIONS TO MAINTAIN EXISTING SERVICES. CONDUIT AND CABLE TRAY TO BE ROUTED CONCEALED UNLESS OTHERWISE NOTED. - CEILING SCHEDULE OA SUSPENDED LAY -IN CEILING OB OPEN CEILING OC SPLINE CEILING OD SUSPENDED PLASTER CEILING OE SUSPENDED PLASTER CEILING OF SUSPENDED GYPSUM CEILING ABBREVIATIONS ACM ASBESTOS CONTAMINATED MATERIAL AP ACCESS PANEL AHJ AUTHORITY HAVING JURISDICTION AWG AMERICAN WIRE GAUGE ARMM ARMORED RISER 24AWG MULTIPAIR CABLE BDF BUILDING DISTRIBUTION FRAME BICSI BUILDING INDUSTRY CONSULTING SERVICES INTERNATIONAL BSC B10 -SAFETY CABINET CCTV CLOSED CIRCUIT TELEVISION CIT CORNELL INFORMATION TECHNOLOGIES CMP COMMUNICATIONS PLENUM RATED CABLE - NEC CMR COMMUNICATIONS RISER RATED CABLE - NEC CTR CIT SUPPORTED EQUIPMENT CABINET WITH ZONE CABLING DDC DIRECT DIGITAL CONTROL SYSTEM DEMARC VERIZON DEMARCATION POINT DN DOWN DOM DEPARTMENT OWNED AND MAINTAINED EF ENTRANCE FACILITY EH&S ENVIRONMENTAL HEALTH AND SAFETY EM EMERGENCY PHONE EMS ENERGY MANAGEMENT SYSTEM ERL "ERL" ADJACENT TO A DEVICE, FIXTURE OR PIECE OF EQUIPMENT INDICATES AN EXISTING ITEM TO BE RELOCATED. DISCONNECT AND REMOVE THE ITEM. REMOVE ALL UNNECESSARY RACEWAY AND WIRING. REINSTALL AND RECONNECT ITEM AS REQUIRED. MAINTAIN SERVICES AS CALLED FOR. ETREQUIPMENT "ETR" ADJACENT TO A DEVICE, FIXTURE OR PIECE OF INDICATES AN EXISTING ITEM TO REMAIN. MAINTAIN EXISTING CONNECTIONS TO EQUIPMENT UNLESS OTHERWISE NOTED. EV ELEVATOR PHONE FACP FIRE ALARM CONTROL PANEL FO/OF FIBER OPTIC / OPTICAL FIBER FH FUME HOOD GWB GYPSUM WALL BOARD IEEE INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS ITR INTERMEDIATE TELECOMMUNICATIONS ROOM JB JUNCTION BOX LAN LOCAL AREA NETWORK LEC LOCAL EXCHANGE CARRIER / TELCO LS LIFE SAFETY MM MULTI -MODE OPTICAL FIBER MTR MAIN TELECOMMUNICATIONS ROOM OFNR OPTICAL FIBER NON-METALLIC STRENGTH RISER RATED OSHA OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION PB PULL BOX PP PATCH PANEL RAP REMOTE ANNUNCIATION PANEL SM SINGLE -MODE OPTICAL FIBER TC TELECOMMUNICATIONS CONTRACTOR TELCO PUBLIC TELEPHONE COMPANY (VERIZON) TGB TELECOMMUNICATION GROUND BUS BAR TMGB TELECOMMUNICATIONS MAIN GROUNDING BAR TIA TELECOMMUNICATION INDUSTRY ASSOCIATION TR TELECOMMUNICATIONS ROOM TYP TYPICAL UNO UNLESS NOTED OTHERWISE UPS UNINTERRUPTIBLE POWER SUPPLY UTP UNSHIELDED TWISTED PAIR VIF VERIFY IN FIELD VOM VERIZON OWNED AND MAINTAINED WAP WIRELESS ACCESS POINT TELECOM SYMBOLS LEGEND (REV. 02/12) DEMO EXISTING NEW DESCRIPTION N ›- ce Q >-- ce z C:C W Z D J J LLI Z E_i_ 0 U El TELECOM OUTLET - FLOOR BOX g \u/ * TELECOM OUTLET - CEILING MOUNTED <1 411 411 TELECOM OUTLET - WALL MOUNTED NETWORK ---- CONDUITS - SIZE AS INDICATED —J— —J— J -HOOKS - WHERE INDICATED CONDUIT WITH BUSHINGS - TYPE & SIZE AS F__.3 [ [ INDICATED PULLBOX: X = SIZE: r--, I PB -X I L_ P B -X — PB X (5) SMALL, (M) MEDIUM, (L) LARGE _J LxWxH LxWxH LxWxH LxWxH = DIMENSIONS IN INCHES 'CTBT CTR CONSTRUCTION DOCUMENTS CTR EQUIPMENT CABINET WITH ZONE CABLING 100% DD SUBMISSION 50 DD 03/23/12 LA1 AP 10/07/11 AP ACCESS PANEL - CEILING MOUNT NSR-# ®SR-# C.sR-# VERTICAL RACEWAY - DOWN (SR -2 UNO) HsR-# HSR-# HSR-# VERTICAL RACEWAY - UP (SR -2 UNO) NCT x ►ICT -x ►4C -X VERTICAL CABLE TRAY - DOWN IIcr x ICT -X ®cr-x VERTICAL CABLE TRAY - UP • • • CONDUIT/SLEEVE - UP 0 0 0 CONDUIT/SLEEVE - DOWN ti o O CONDUIT/SLEEVE - THRU (BETWEEN FLOORS) HORIZONTAL RACEWAY - SIZED PER PATHWAY [E -I] sR-# SCHEDULE HORIZONTAL CABLE TRAY - SIZED PER [Cf --5g CT -x PATHWAY SCHEDULE SHEET TITLE: STANDARD SYMBOLS, NOTE S ABBREVIATIONS (T -SERIES) H H IIH DIE CABLE RUNWAY 0 Cs SPLICE CASE ��] P n COMMUNICATIONS POWER POLE -—a- SERVING ZONE OR MTR/ITR BOUNDARY _ _ _ = CTR SERVING ZONE BOUNDARY NEW / EXISTING OUTLET SUBSCRIPT KEY (REFER TO ADDITIONAL DESCRIPTORS THIS DRAWING) 41.,P -A1 "A" ROOM LOCATION CODE "#" EXISTING OUTLET NOTE "xx" EXISTING PATHWAY TYPE TO BE REUSED "yy" OUTLET DESCRIPTOR "zz" NEW PATHWAY TYPE YY ZZ YY NEW PATHWAY TYPE KEY CC CONDUIT TO CEILING CF CONDUIT TO FLOOR CH CONDUIT TO HALL CI CONDUIT HOMERUN TO ITR/MTR CP CONDUIT TO PULLBOX CT CONDUIT TO CABLE TRAY FW FISHABLE WALL JP J -HOOK TO PULLBOX JS J -HOOK TO SLEEVE JT J -HOOK TO CABLE TRAY PT PULLBOX TO CABLE TRAY SC SURFACE RACEWAY TO CEILING SF SURFACE RACEWAY TO FLOOR SW SURFACE THROUGH WALL SH SURFACE RACEWAY TO HALL (RACEWAY THROUGH ROOM TO HALLWAY PRIMARY HORIZONTAL PATHWAY) DOB NEW DEVICE OPENING IN EXISTING SURFACE RACEWAY, WITH BLANK PLATE (MATCH EXISTING COLOR) NOTE: PROVIDE MINIMUM 1" CONDUIT UNLESS NOTED OTHERWISE. INCREASE SIZE AS REQUIRED PER CABLE FILL CHART. NOTE: PROVIDE MINIMUM SIZE METALLIC RACEWAY BASED ON CABLE FILL CHART UNLESS NOTED OTHERWISE. NOTE: ASSUME PATHWAY TYPE "CP" UNLESS NOTED OTHERWISE. OUTLET DESCRIPTOR KEY ##" HEIGHT ABOVE FINISHED FLOOR (AFF) - EXAMPLE: 48" BAC BUILDING ACCESS CONTROLLER EM EMERGENCY TELEPHONE OUTLET EV ELEVATOR TELEPHONE LINE CONNECTION EMS ENERGY MANAGEMENT FACP FIRE ALARM CONTROL PANEL OC OVER COUNTER MOUNTING W WALL MOUNTED TELEPHONE OUTLET TO BE MOUNTED AT 48" AFF WAP WIRELESS ACCESS POINT - REFER TO DETAIL AT -27052839. EXISTING OUTLET NOTE KEY A EXISTING DEVICE OR OPENING WITH LEGACY CABLING. REMOVE " CABLING, PAINT/PATCH OR PROVIDE BLANK AS APPLICABLE. EXISTING ONE -GANG BOX AND PATHWAYS TO BE REUSED AS A INDICATED. MAINTAIN EXISTING SERVICES UNTIL AFTER CUTOVER, THEN REMOVE CABLING. EXISTING TWO -GANG BOX AND PATHWAYS TO BE REUSED AS INDICATED. MAINTAIN EXISTING SERVICES UNTIL AFTER CUTOVER, THEN REMOVE CABLING. EXISTING OUTLET LOCATION IN SURFACE RACEWAY. PATHWAYS TO BE REUSED AS INDICATED. MAINTAIN ANY EXISTING SERVICE UNTIL AFTER CUTOVER, THEN REMOVE CABLING. PROVIDE DEVICE BRACKETS AS REQUIRED. EXISTING PATHWAYS, BOXES, RACEWAYS AND CAT.5, CAT.5E OR CAT.6 CABLES TO REMAIN. EXISTING PATHWAYS, BOXES AND RACEWAYS TO REMAIN. COORDINATE SHUTDOWN AND CONDUIT/CABLE REWORK TO A\ RELOCATE FROM EXISTING TR TO NEW TR PER T1 -PL, T1 -SZ AND APPENDIX A. REASSIGN CABLE PANEL/PORTS AS CALLED FOR. EXISTING INTERCOM PHONE IS CONNECTED TO STAND ALONE SYSTEM. OUTLET AND ALL ASSOCIATED WIRING TO REMAIN. EXISTING ONE -GANG BOX AND CONDUIT PATHWAYS DOWN TO A BASEMENT PATHWAY SYSTEM TO BE REUSED AS INDICATED. MAINTAIN EXISTING SERVICES UNTIL AFTER CUTOVER, THEN REMOVE CABLING. EXISTING TWO -GANG BOX AND PATHWAYS DOWN TO BASEMENT /e\ PATHWAY SYSTEM TO BE REUSED AS INDICATED. MAINTAIN EXISTING SERVICES UNTIL AFTER CUTOVER, THEN REMOVE CABLING. EXISTING OUTLET LOCATION IN SURFACE RACEWAY. PATHWAYS THROUGH RACEWAY AND DOWN TO BASEMENT PATHWAY SYSTEM TO BE REUSED AS INDICATED. MAINTAIN ANY EXISTING SERVICE UNTIL AFTER CUTOVER, THEN REMOVE CABLING. PROVIDE DEVICE BRACKETS AS REQUIRED. CABLING SYMBOLS LEGEND 2B -101-A1 CABLE IDENTIFICATION LABEL: 2B COMMUNICATIONS EQUIPMENT ROOM 101 MASTER LOCATION CODE A ROOM LOCATION CODE 1 POSITION J:\PROJECTS-Ithaca\2011\ 11103 CORNELL - NCP\Olin Library 2047\CAD\ 11103-2047- -T-GEN.dwa SCALES ON THIS DRAWING ACCURATE WHEN PLOTTED TO: ARCH El (30X42 IN.) MEM &HAI 115 METRO PHONE: ARCHIMTECHNOLOGY, LLC www.archi-technology.com PARK ROCHESTER, NY 14623 585.424.1952 Fax: 585.424.4239 N ›- ce Q >-- ce z C:C W Z D J J LLI Z E_i_ 0 U co F—I C4e U z Q __I Z 0 CLIENT: Cornell University PROJECT NETWORK m CONNECTIVITY `.D 06/29/12 CONSTRUCTION DOCUMENTS 100 DD 05/17/12 100% DD SUBMISSION 50 DD 03/23/12 50% DD SUBMISSION 20 SD 10/07/11 20% SD SUBMISSION PSD 08/26/11 PRELIMINARY SD MARK DATE DESCRIPTION CONSTRUCTION DOCUMENTS ISSUE DATE: 06/29/12 ..vim fi AT PROJECT NO: 11103-2047 OWNER PROJECT NO: 754 DRAWN BY: PKB CHECKED BY: JLB PROJECT MANAGER: GHS SHEET TITLE: STANDARD SYMBOLS, NOTE S ABBREVIATIONS (T -SERIES) CD L 0 Q r co 0 0 N 0 N 0. a) PLOT DATE: COScale: NONE NOT USED PROVIDE INSULATION SHIELD & INSERT FOR ALL PIPING BAND HANGER RODS CHANNEL OR SIDE VIEW ANGLE TRAPEZE HANGER HANGER ROD INSULATION INSULATION SHIELD AT HANGER PROVIDE HIGH COMPRESSIVE STRENGTH INSUL INSERT BETWEEN PIPE & INSULATION SHIELD ADJUSTABLE CLEVIS HANGER NOTE: REFER TO PROJECT SPECIFICATION FOR ROD DIAMETER, END CONDITION (CLAMP, ANCHOR, ETC.) HANGER TYPES, AND CONFIGURATION. HANGER ROD INSULATION WELD SADDLE ADJUSTABLE ROLLER HANGER PIPE HANGER Scale: NONE UNISTRUT CONCRETE ANCHORS WALE TYPICAL CHILLED WATER PIPE PROVIDE B -LINE ARMAFIX CLAMP OR EQUAL PROVIDE INSULATION CONTINUOUS THROUGH CLAMPS NOTES: 1. PROVIDE PIPE SUPPORT EVERY 4 FT. - MINIMUM OF 2 SUPPORTS. CHILLED WATER PIPING WALL SUPPORT DETAIL Scale: NONE J:\PROJECTS-Ithaca\2011\ 11103 CORNELL - NCP\Olin Library 2047\CAD\ 1 1 103-2047--AMEP.dwc Q CONCRETE DECK EXPANSION SHIELDS CONCRETE ANCHORS WASHER (TYPICAL) EXPANSION NAILS NOTE: REFER TO SPECIFICATION FOR REQUIRED ANCHOR CONFIGURATION. coONCRETE ANCHOR DEVICE DETAIL L) Scale: NONE PROVIDE ESCUTCHEON PLATES AT ALL PIPE PENETRATIONS EXPOSED TO VIEW. SIZE ESCUTCHEON AROUND INSULATION ON INSULATED PIPE AND AROUND PIPE ON UNISULATED PIPES Vr NON—FIRE RATED WALL SLEEVE WHERE REQUIRED BY SPECIFICATIONS \\\\\\ \ \\ \ \\\\\\)\ \\\\\\\\\\\\\\\\\\y PIPE PIPE INSULATION — RUN INSULATION CONTINUOUS THROUGH WALL OPENING. PIPE PROVIDE 1" CLEARANCE ALL AROUND NON FIRE RATED WALL PIPE PENETRATION Scale: NONE PROVIDE ESCUTCHEON PLATES AT ALL PIPE PENETRATIONS EXPOSED TO VIEW. SIZE ESCUTCHEON AROUND INSULATION ON INSULATED PIPE AND AROUND PIPE. ON UNISULATED PIPES FIRE RATED WALL SLEEVE WHERE REQUIRED HY SPECIFICATIONS PIPE INSULATION — BUTT TIGHT TO FIRESTOPPING SYSTEM PROVIDE FIRESTOPPING SYSTEM PER SPECIFICATIONS FIRE RATED WALL PIPE PENETRATION Scale: NONE FLOW BALANCING VALVE ISOLATION VALVE (TYPICAL) = C COIL MANUAL AIR VENT 0 NOTES: 1. PIPING TO ALLOW REMOVAL OF COIL WITH OUT REMOVING PIPING BEYOND UNIONS OR FLANGES. \--UNION/FLANGE (TYPICAL) STRAINER AIR FLOW PETE'S PLUGS (TYPICAL) THERMOMETER (TYPICAL) f DRAIN W/HOSE END CONTROL VALVE 2. FOR UNITS WITH MORE THAN ONE SECTION, PROVIDE FLOW BALANCER, UNIONS/ FLANGES, FLEXIBLE CONNECTORS, DRAINS AND AIR VENTS FOR EACH COIL. TWO-WAY CONTROL VALVE COIL PIPING DETAIL Scale: NONE CONNECT CONDENSATE HOSE TO 3/4" HARD PIPE WITH DISHWASHER TAILPIECE 3/4" CONDENSATE HARD PIPE SLOPE TO DRAIN LITTLE GIANT CONDENSATE PUMP FC -3 WALL MOUNT SEE ENLARGED `/iEW PUMP DISCHARGE CONDENSATE CONDENSATE PUMP (MOUNT TO WALL) MIN 2D" AIR GAP PROVIDE FUNNEL SIZE LARGE ENOUGH TO PREVENT SPLASHING OF CONDENSATE CONDENSATE PUMP ENLARGED VIEW KEYED NOTES: 1. PROVIDE INDIRECT CONDENSATE CONNECTION TO CONDENSATE PUMP. FC -3 CONDENSATE DETAIL Scale: NONE COOLING COIL DRAIN SF PLANS - �� `E PLANS E -OR CONTINUATION NOTE: L =INCH (MINIMUM) H =INCH PLUS THE TOTAL UNIT STATIC PRESSURE AT WORST CASE (LOADED FILTERS) UNDER POSITIVE PRESSURE COOLING COIL DRAIN SEE PLANS FOR CONTINUATION GENERAL NOTES . REFER TO DRAWING AMEP-GEN CONNECT TO EXISTING COOLING COIL CONDENSATE DRAIN NOTE: L = H + J + PIPE DIAMETER H = 1 INCH FOR EACH INCH OF NEGATIVE PRESSURE* + 1 INCH J = jH * NEGATIVE PRESSURE = TOTAL UNIT STATIC PRESSURE AT WORST CASE (LOADED FILTERS) MINUS EXTERNAL PRESSURE UNDER NEGATIVE PRESSURE CONNECT TO EXISTING COOLING COIL CONDENSATE DRAIN TYPICAL COOLING COIL DRAIN Scale: NONE UNIT LOCATION AIRFLOW ELECTRICAL CHILLED WATER COIL Architecture, Engineering, Landscape Architecture, P.C. Pit 315.472.6980 5789 Widewaters Parkway Fax 315-472.3523 Dewitt, New York 13214 E-mail 1 DAtiff1 esrs3sley.esm MOTOR HP (WATTS) V PH FLA EDB EWB LDB LWB TOTAL MBH SENSIBLE MBH EWT LWT GPM FLUID PD MANUF/MAKE NOTES FC -1 MTR-SBA 440 1/10 115 1 1.9 75 63 55.6 54.2 10.8 8.8 52 62 1.7 10 ENVIRO TEC HLE40 1,2,3,4,5,7 ' FC -2 ITR -3A 510 (62) 115 1 1.2 75 63 55 54 13.4 11.2 52 62 2.5 4.4 EMI WCP-15 2,6,7 FC -3 ITR -6A 245 (23) 115 1 .64 75 63 55 54 6.4 5.3 52 62 1.5 .8 EMI WCP-09 2,6,7 NOTES: 1. PROVIDE STANDALONE CONTROLS WITH FACTORY WALL MOUNTED THERMOSTAT. 2. PROVIDE 1" FILTER 3. PROVIDE SUPPLY DISCHARGE DEFLECTION GRILLE. 4. PROVIDE FAN SPEED CONTROLLER UNIT MOUNTED. 5. PROVIDE BOTTOM HINGED COVER ELECTRICAL ENCLOSURE. 6. PROVIDE UNIT MOUNTED CONTROLS. 7. EWT = 52° DURING WINTER MONTHS. EWT = 47° DURING SUMMER MONTHS. SCALES ON THIS DRAWING ACCURATE WHEN PLOTTED TO: ARCH El (30X42 IN.) NEW CHILLED WATER FAN COIL UNIT SCHEDULE Scale: NONE r rf- DB 115 METRO PHONE: ARCHIMTECHNOLOGY, LLC www.archi-technolo9Y .corn PARK ROCHESTER, NY 14623 585.424.1952 Fax: 585.424.4239 BEARDSLEY DESIGN Architecture, Engineering, Landscape Architecture, P.C. Pit 315.472.6980 5789 Widewaters Parkway Fax 315-472.3523 Dewitt, New York 13214 E-mail 1 DAtiff1 esrs3sley.esm li N o N >-- i'Y >- ce z CO F --a Q z Q cf) H pe `W / Z D J _J W Z lY Q U I --I _ J 0 CLIENT: Cornell University PROJECT ® NETWORK q uIJ r 4 CONNECTIVITY � CD 06/29/12 CONSTRUCTION DOCUMENTS 100 DD 05/17/12 100% DD SUBMISSION 50 DD 50% DD SUBMISSION 20 SD 20% SD SUBMISSION PSD 08/05/11 PRELIMINARY SD MARK DATE DESCRIPTION CONSTRUCTION DOCUMENTS ISSUE DATE: 06/29/12 ,s,t- ek EaF NEw 014DN.c0, a..L 7r ^gin► © 6315'' �� Vo Stio'NP�� AT PROJECT NO: 11103-2047 OWNER PROJECT NO: 754 DRAWN BY: PKB CHECKED BY: JLB PROJECT MANAGER: GHS SHEET TITLE: MECHANICAL DETAILS OT BY: obarrie C) C w 10 F- 0 — A 610 611 600ED 3/4" CONDENSATE UP 600UB 600SA DN 600EC 600EA 600EB 60016 600JB 600TA 600JA 3/4" CHWS&R DN TO 3RD FL. REFER TO DETAIL 1 THIS SHEET II II 3/4" CHWS&R II II II II II II II I II II II 11 II 1 61 SIXTH FLOOR MECHANICAL - NEW WORK Scale: 3/32" = 0 4' 8' 16' !TR -6A (RM. 625A) SIXTH FLOOR KEY PLAN ' — 3/4" CONDENSATE DN TO EX. FLOOR DRAIN 2BOOUK EXISTING FLOOR DRAIN 1 REFER TO DRAWING AMEP-3A 3/4" CHWS&R UP TO 6TH FL. REFER DETAIL 2, THIS SHEET 3/4" CHWS&R TO MTR—SBA THIRD FLOOR MECHANICAL - NEW WORK Scale: 3/32" = 0 4' 8' 16' 11, 3/4" CHWS&R 28018 FC -1 2B01A 2 B01 2BOOUA 3/4" CONDENSATE PROVIDE CLEANOUTS AT ELBOWS I 2802 IIHIIH 'mom 2ROOSA 2BOOSA P 2BOOUB L 2BOOUL I2BOOUAI 2BOOUC 2BOOUL 2800T-7 2BOOSB 28000 SHUT OFF VALVE SHUT OFF VALVE lop 2BOOUE 3/4" CHWS&R INF —TO'114EX. III 6" CHWS CHILLED (ETR) WATER. PUMP N UN 3" CHWR 2BOOUD (ETR) SUB BASEMENT FLOOR MECHANICAL - NEW WORK Scale: 3/32" = l'-0" 0 4' 8' 16' 1111111111111 ITR -3A (RM. 325A) THIRD FLOOR KEY PLAN 2BOOU F RE—BALANCE EX CHILLED WATER. PUMP TO ACCOMMODATE ADDITIONAL 5.7 GPM 2BOOUG 2BOOUH SUB BASEMENT KEY PLAN 3/4" CHSW&R GENERAL NOTES: A. REFER TO DRAWING AMEP—GEN. B. REFER TO DRAWINGS AMEP—SBA, AMEP-3A AND AMEP 6—A FOR CONTINUATION AND ADDITIONAL COORDINATION REQUIREMENTS. HVAC CONSTRUCTION KEYED NOTES: ®PROVIDE 3/4" CONDENSATE DN TO SINK. PROVIDE DISHWASER TAIL PIECE ON DRAIN PIPE OF SINK. CONNECT 3/4" CONDENSATE HARD PIPE TO DISHWASHER TAIL PIECE WITH 3/4" RUBBER TUBE. NOTE: REFER TO DRAWING M4 FOR DETAILS AND SCHEDULES AS APPLICABLE. EX. 1-1/2" CHWS&R TO REMAIN EX. FCU —1 EX, 1" CHWS&R TO REMAIN 200UA r ITR -3A ABOVE r AI 20OUBI 3/4" CONDENSATE UP TO FC -2 CONNECT 3/4" CHWS&R TO—' EX, STUBBED CONNECTION I EX. 1" CHWS&R TO REMAIN L SECOND FLOOR (ROOM 236) MECHANICAL - NEW WORK Scale: 3/32" = 1'-0" 0 2 4' 8' CONNECT if4" CONDENSATE EX. TO EX. FCU 2 CONDENSATE FCU—2 TO 3/4" CHWS&R UP TO FC -2 & FC -3 SECOND FLOOR KEY PLAN JAPROJECTS-Ithaca12011\11103 CORNELL - NCP\Olin Library 2047\CAD\M-2 AMEP ENLARGED PLAN-MECHANICAL.dwg SCALES ON THIS DRAWING ACCURATE WHEN PLOTTED TO: ARCH El (30X42 IN.) greae MPARCHI-TECHNOLOGY Einallb 115 METRO PHONE: LLC www.archi-technology.com PARK ROCHESTER, NY 14623 585.424.1952 Fax: 585.424.4239 _r 1 IBEARADSLEY Architecture, Engineering, Landscape Architecture, P.C. Ph 315.472_6980 5789 Widewaters Parkway Fax 315.4,72.3523 Dewitt, New York 13214 E-mail IIDAineardsley.cem U21011:iri N CD N >-- Ct < >-- Ct Z CO 1--1 .._I < U Z < _...1 i 200UA r ITR -3A ABOVE r AI 20OUBI 3/4" CONDENSATE UP TO FC -2 CONNECT 3/4" CHWS&R TO—' EX, STUBBED CONNECTION I EX. 1" CHWS&R TO REMAIN L SECOND FLOOR (ROOM 236) MECHANICAL - NEW WORK Scale: 3/32" = 1'-0" 0 2 4' 8' CONNECT if4" CONDENSATE EX. TO EX. FCU 2 CONDENSATE FCU—2 TO 3/4" CHWS&R UP TO FC -2 & FC -3 SECOND FLOOR KEY PLAN JAPROJECTS-Ithaca12011\11103 CORNELL - NCP\Olin Library 2047\CAD\M-2 AMEP ENLARGED PLAN-MECHANICAL.dwg SCALES ON THIS DRAWING ACCURATE WHEN PLOTTED TO: ARCH El (30X42 IN.) greae MPARCHI-TECHNOLOGY Einallb 115 METRO PHONE: LLC www.archi-technology.com PARK ROCHESTER, NY 14623 585.424.1952 Fax: 585.424.4239 SSOCIATES DESIGN IBEARADSLEY Architecture, Engineering, Landscape Architecture, P.C. Ph 315.472_6980 5789 Widewaters Parkway Fax 315.4,72.3523 Dewitt, New York 13214 E-mail IIDAineardsley.cem U21011:iri N CD N >-- Ct < >-- Ct Z CO 1--1 .._I < U Z < _...1 i CLIENT: ii.4 q NETWORK „,4 Cornell University ) CONNECTIVITY PROJECT CD 06/29/12CONSTRUCTION DOCUMENTS 100 DD 05/17/12 100% DD SUBMISSION 50 DD 03/23/12 50% DD SUBMISSION 20 SD 10/07/11 20% SD SUBMISSION PSD 08/26/11 PRELIMINARY SD MARK DATE DESCRIPTION CONSTRUCTION DOCUMENTS ISSUE DATE: 06/29/12 ,oF NEwy ,P- ND N. co ° -f- it- . 4r -, : :,....t. lir- 40 AT PROJECT NO: 11103-2047 OWNER PROJECT NO: 754 DRAWN BY: PKB CHECKED BY: JLB PROJECT MANAGER: GHS SHEET TITLE: AMEP ENLARGED PLANS -MECHANICAL M...2 1 PAN -L3OA9 S GULF NOTES: SE RATED HINGED TRIM n COMPUTER GRADE in 200% NEUTRAL FEED-THRU LUGS n SUB -FEED BREAKER n SUB FEED LUGS ISOLATED GND BUS NAME LOCATION SOURCE RATING (AMPS) CP TRSBA MTR—SBA MCB MLO PH/WIRE VO LTAG E MOUNTING KAIC DESIGN MAKE NEMA TYPE 60A 3 / 4 120/208 SURFACE 10 CKT NO DESCRIPTION BREAKER KVA LOAD PH. A PH. B PH. C KVA LOAD PH. A PH. B PH. C BREAKER DESCRIPTION CKT NO 1 3 5 7 9 11 13 15 17 19 21 23 UPS RECEPTACLE RECEPTACLES ACCESS CONTROL SPARE SPARE SPARE SPARE SPARE SPARE 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 1.8 0.7 0.1 FEED TO CP TR3A 40/3 1.8 0.7 20/1 20/1 UPS RECEPTACLE RECEPTACLES 2 4 0.2 20/1 FC —1 6 20/1 SPARE 8 20/1 SPARE 10 20/1 SPARE 12 20/1 SPARE 14 20/1 SPARE 16 20/1 SPARE 18 20/1 SPARE 20 20/1 SPARE 22 20/1 SPARE 24 PAN ROAR ID SC DL NOTES: SE RATED HINGED TRIM COMPUTER GRADE 200% NEUTRAL ❑ FEED-THRU LUGS n SUB -FEED BREAKER n SUB FEED LUGS ISOLATED GND BUS n NAME LOCATION SOURCE RATING (AMPS) CP TR6A ITR — 6A MCB MLO PH/WIRE VOLTAGE MOUNTING KAIC DESIGN MAKE NEMA TYPE 60A 3 / 4 120/208 SURFACE 10 CKT NO DESCRIPTION I BREAKER KVA LOAD PH. A PH. B PH. C KVA LOAD PH. A I PH. B PH. C BREAKER DESCRIPTION CKT NO 1 UPS RECEPTACLE 20/1 1.8 3 RECEPTACLES 20/1 0.7 5 FC -3 20/1 0.1 7 SPARE 20/1 9 SPARE 20/1 11 SPARE 20/1 13 SPARE 20/1 15 SPARE 20/1 17 SPARE 20/1 19 SPARE 20/1 21 SPARE 20/1 23 SPARE 20/1 1.8 20/1 UPS RECEPTACLE 2 0.1 20/1 ACCESS CONTROL 4 20/1 SPARE 6 20/1 20/1 SPARE 8 SPARE 10 20/1 SPARE 12 20/1 SPARE 14 20/1 SPARE 16 20/1 SPARE 18 20/1 SPARE 20 20/1 SPARE 22 20/1 SPARE 24 SAN BOARD SC 9, L NOTES: SE RATED HINGED TRIM COMPUTER GRADE 200% NEUTRAL ❑ FEED-THRU LUGS SUB FEED LUGS SUB -FEED BREAKER ISOLATED GND BUS ❑ NAME LOCATION SOURCE RATING (AMPS CP TR3A ITR -3A MOB 0 P-I/WIRE VOLTAGE MOUNTING KAIC DESIG\ MAKE NEMA TYPE 60A 3 / 4 120/208 SURFACE 10 CKT NO u�SC IPTON <VA LOAD PH. A PH. B PH. C <VA LOAD PH. A PH. B PH. C A 1/ E) IlEcC'DI Li L._ L., I \ 1 I1\JIV C<T NO UPS RECEPTACLE 20/1 1.8 3 UPS RECEPTACLE RECEPTACLE 20/1 1 .8 20/1 0.9 7 FC -2 20/1 0.1 9 SPARE 20/1 11 SPARE 20/1 13 SPARE 20/1 15 SPARE 20/1 17 SPARE 20/1 19 21 23 FEED TO CP TR6A 40/3 1.8 1.8 20/1 20/1 UPS RECEPTACLE UPS RECEPTACLE 2 4 0.1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 20/1 ACCESS CONTROL SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE SPARE 6 8 10 12 14 16 18 20 22 24 ELECTRICAL PANELBOARD SCHEDULES Scale: NONE EIGHTH FLOOR SEVENTH FLOOR SIXTH FLOOR FIFTH FLOOR FOURTH FLOOR THIRD FLOOR SECOND FLOOR FIRST FLOOR BASEMENT SUB -BASEMENT GENERAL NOTES 1. REFER TO DRAWING AMEP—GEN ELECTRICAL CONSTRUCTION <EYED NOTES° E1 PROVIDE #6 AWG GROUNDING CONDUCTOR TO ANTI—STATIC FLOOR PIGTAIL. POWER & GROUNDING SYSTEM RISER DIAGRAM f";• -mss � �%� �^1����� Sca:e: V ONE FIXTURE LAMPS REMARKS TYPE DESCRIPTION VOLTS MANUFACTURER & CATALOG NUMBER NEW PANEL i WITH 60A MAIN ' BREAKER , _ (I PANEL CP LAMP CODE #6 A6 AWG WG ITR -6A 4 FT. SURFACE FLUORESCENT WITH HIGH IMPACT ACRYLIC LENS AND ELECTRONIC BALLAST I TR6A TGB STEL I RM. 625A 1,2,3 FB 2 FT. SURFACE FLUORESCENT WITH HIGH IMPACT ACRYLIC LENS AND ELECTRONIC BALLAST 120/277 LI THONIA LB-217—MVOLT—GEB101 S 2 17 F017T8/835 #3/0, 3/4"C #3/0, 3/4"C EM TWIN HEAD EMERGENCY LIGHTING UNIT 120/277 MCPHILBEN CFX6 2 5 HALOGEN NOTES: 1. FURNISH WITH <10% THD ELECTRONIC BALLAST. 2. FURNISH WITH HIGH IMPACT PRISMATIC DIFFUSER. 3. PROVIDE 24" PENDANT NEW PANEL —�� WITH 60A MAIN BREAKER � I PANEL CONSTRUCTION DOCUMENTS #6 AWG , ITR -3A 05/17/12 100% DD SUBMISSION 50 DD 73A TGB STEEL RM. 325A 20% SD SUBMISSION PSD 08/05/11 PRELIMINARY SD MARK DATE #6 AWG CONSTRUCTION DOCUMENTS (4) #6 AWG, (1)#8er AWG GROUND, 1"C Of #3/0, 3/4"C (4) #4 AWG, (1)#8 AWG GROUND, 1-1 /4"C .©F NElN 1- - 014D N. co Nt- ''.4,44-t �=V 063155 �� StONP�� AT PROJECT NO: 11103-2047 OWNER PROJECT NO: 754 DRAWN BY: PKB CHECKED BY: JLB PROJECT MANAGER: GHS SHEET TITLE: ELECTRICAL DETAILS E4 (4) #4 AWG, (1)#8 AWG EX. PROVIDE PROVIDE GROUND, 1-1 /4"C GROUND 60A/3P 60A/3P BUS BREAKER BREAKER NEEW } #3/0, 3/4"C PA ' WITH 60A ( �ti -- MBREAKER N #6 #6 I AWG AWG ) ' 40A/3P PANEL CP ' MTR—SBA j EX. SECONDARY • EX. SWITCHBOARD ® ' RM. BREAKER I TRSBA ` ' TMGB" STEEL RM. 2601 A SWITCHBOARD EMPP 2B000H ELECTRICAL CONSTRUCTION <EYED NOTES° E1 PROVIDE #6 AWG GROUNDING CONDUCTOR TO ANTI—STATIC FLOOR PIGTAIL. POWER & GROUNDING SYSTEM RISER DIAGRAM f";• -mss � �%� �^1����� Sca:e: V ONE FIXTURE LAMPS REMARKS TYPE DESCRIPTION VOLTS MANUFACTURER & CATALOG NUMBER QTY. WATTS LAMP CODE FA 4 FT. SURFACE FLUORESCENT WITH HIGH IMPACT ACRYLIC LENS AND ELECTRONIC BALLAST 120/277 LITHONIA CLM-232—MVOLT—GEB 2 32 F032T8/835 1,2,3 FB 2 FT. SURFACE FLUORESCENT WITH HIGH IMPACT ACRYLIC LENS AND ELECTRONIC BALLAST 120/277 LI THONIA LB-217—MVOLT—GEB101 S 2 17 F017T8/835 1,2 EM TWIN HEAD EMERGENCY LIGHTING UNIT 120/277 MCPHILBEN CFX6 2 5 HALOGEN NOTES: 1. FURNISH WITH <10% THD ELECTRONIC BALLAST. 2. FURNISH WITH HIGH IMPACT PRISMATIC DIFFUSER. 3. PROVIDE 24" PENDANT LIGHTING FIXTURE SCHEDULE Scale: NONE EIGHTH FLOOR SEVENTH FLOOR SIXTH FLOOR FIFTH FLOOR FOURTH FLOOR THIRD FLOOR SECOND FLOOR FIRST FLOOR BASEMENT SUB -BASEMENT TMGB OR TGB LABEL 0 PROVIDE ENGRAVED TAG FOR EACH GROUNDING CONDUCTOR, BOTH ENDS AND AT EXPOSED PASS THROUGH MECHANICAL SPACES AND AT ENTRANCES/ EXITS TO SHAFTWAYS, TYPICAL. DIV. 26 CONTRACTOR TO PROVIDE INSULATED TIN PLATED TELECOM SYSTEM GROUND BUS BAR. HOLE CENTERS TO MATCH LUG CONFIGURATION AND EIA/TIA 607 STANDARDS. REFER TO SECTIONS 260526 and 271100. TMGB — ERICO/ERITECH # TMGB—A20L27PT TGB — ERICO/ERITECH # TGB—A20L12PT 0 INSULATORS. O 5/8" LOCKWASHERS. (i) WALL MOUNTING BRACKET. O 5/8-11X1" H.H.C.S. BOLTS. 0 DIV. 26 CONTRACTOR TO PROVIDE LONG BARREL COMPRESSION LUG, TWO BOLT, COMPRESSION LUG (BURNDY HYLUG YAZ SERIES) OR EQUAL. PROVIDE A MINIMUM OF EIGHT (8) SPARE LUGS WITH 5/16" HOLES FOR FUTURE USE BY OWNER. DRILL AND TAP AS REQUIRED. SCRUFF BAR AND PROVIDE ANTIOXIDANT AS CALLED FOR. REFER TO SECTIONS 260526 and 271100. TELECOMMUNICATIONS GROUND BAR (TMGB,TGB) DETAIL Scale: NONE J:\PROJECTS—Ithaca\2011\ 11 103 CORNELL — NCP\Olin Library 2047\CAD\ 1 1 103-2047--AMEP.dw i SCALES ON THIS DRAWING ACCURATE WHEN PLOTTED TO: ARCH El (30X42 IN.) ralligii AW 115 METRO PHONE: ARCHI-TECHNOLOGY, LLC www.archi-technolo9Y .corn PARK ROCHESTER, NY 14623 585.424.1952 Fax: 585.424.4239 wih A. BEARDSLEY DESIGN . ASSOCIATES Architecture, Engineering, Landscape Architecture, P.C. Ph 315.472.6980 5789 Widewaters Parkway Fax 315.472_3523 Dewitt, New York 13214 B -mail I3)A@Beardaley.cam N 4 V N fY Q ›- e: z m 1--4Q J UQ 0 I I C W›... F --I Z D J W Z o o CLIENT: Cornell University PROJECT 4 h� CONNECTIVITY ��.$0 NETWORK fad CD 06/29/12 CONSTRUCTION DOCUMENTS 100 DD 05/17/12 100% DD SUBMISSION 50 DD 50% DD SUBMISSION 20 SD 20% SD SUBMISSION PSD 08/05/11 PRELIMINARY SD MARK DATE DESCRIPTION CONSTRUCTION DOCUMENTS ISSUE DATE: 06/29/12 co.s F ‹,b.„0 �pR4F; .©F NElN 1- - 014D N. co Nt- ''.4,44-t �=V 063155 �� StONP�� AT PROJECT NO: 11103-2047 OWNER PROJECT NO: 754 DRAWN BY: PKB CHECKED BY: JLB PROJECT MANAGER: GHS SHEET TITLE: ELECTRICAL DETAILS E4 June 21, 2012 0 0 0 T T T T T T T T X I X—x Xj—r--x c � x— )'x x x � Tx 2B01A 11- I I- I I- I I I l ai I I l I a! I I I I ■ i i UP xxxxxxxxxxxxxx i 2BOOSA - I I 1101111111111111 I I aim I I l I N I I MEM= I I 2E SUB -BASEMENT IDF (ROOM 2B01A) ARCHITECTURAL -EXISTING / DEMO Scale: 1/4" = 1'-0" 0 2' 4' 8' 1 -be- (ER L (ERL) EX. SPRINKLER LINES (ETR) Cfp (ETR) REMOVE EX. DRAIN PAN AND EX. DRAIN HOSE. 2BO'A� REMOVE EX. UPRIGHT SPRINKLER I I farnaalll I I i ! x-I—xx x x (ETR) I I I UP 2 BOOSA SUB -BASEMENT IDF (ROOM 2BO1A) MECHANICAL -EXISTING / REMOVALS Scale: 1/4" = i'-0" 0 2' 4' 8` X(ERL) x x (ETR) (ETR) r E2 2BO1A r E2 1 2E L x-- / x x—X---X — x x .4 UP 2BOOSA 0 (ErR) SUB -BASEMENT IDF (ROOM 2B01A) ELECTRICAL -EXISTING / REMOVALS Scale: 1/4" = 1,-0" 0 2' 4' 8' X X X X X X X X X X X X 15'-4" +/— ALIGN WITH WIRE MESH PARTITION ;2801 B X X X X X X X X X X X X X X I I I i- I I- I I i I I I I M I I 2B01A SRI RL UP XXXXXXXXXXXX X 2BOOSA I I= I I 111111111111111111 I I- I I O i I 11111111111111111 I I SUB -BASEMENT MTR-SBA (ROOM 2B01A) ARCHITECTURAL - NEW WORK Scale: 1/4" = 1'-0" 0 2' 4' 8' I I III 2 x x1 REFER TO DRAWING M2 FOR CONTINUATION EX. SPRINKLER LINES (ETR) 3/4" CHWS&R REFER TO DRAWING M2 2B01A (ETR) r -FC - X X x x X x (ETR) X x X X 2B0' REFER TO DRAWING M2 FOR CONTINUATION UP L2BoosA I SUB -BASEMENT MTR-SBA (ROOM 2B01A) MECHANICAL - NEW WORK Scale: 1/4" = 1'-0" 0 2' 4' 8' 11111111111/1/1111111111 X X x X X X X a@ X X X X ER L) PROVIDE PANEL CP TRSBA 5 CP TRSBA, 3 CRL CP TRSBA, 4 CP TRSBA, 6 X X UP X X X X X X X X X X X X X 2BOOSA ®(ETR) SUB -BASEMENT MTR-SBA (ROOM 2B01A) ELECTRICAL - NEW WORK Scale: 1/4" = 1'-0" 0 2' 4' 8' X 2 ARCHITECTURAL — GENERAL NOTES & CONSTRUCTION KEYED NOTES: A. EXISTING AND NEW PARTITIONS ON THIS PLAN ARE NOT FIRE RATED. B. REFER TO DRAWING A4 FOR DETAILS. Al PROVIDE ANTI—STATIC VINYL COMPOSITION FLOOR AND RUBBER BASE. PROVIDE RUBBER TRANSITION STRIP AT EXPOSED EDGE UNDER DOOR. 0 PROVIDE 3/4" AC PLYWOOD ON WALLS INDICATED ON THIS PLAN. PRIME AND PAINT WITH FIRE RETARDANT, LIGHT GRAY PAINT ON ALL SURFACES AND EDGES. PLYWOOD TO BE 8 FEET HIGH AND MOUNTED 6 INCHES ABOVE FLOOR. SECURE TO WALL WITH COUNTERSINK FASTENERS 24 INCHES ON CENTER MAXIMUM, EACH WAY. ANCHOR TO STUDS WITH SCREWS. ANCHOR TO CONCRETE OR MASONRY WITH EXPANSION ANCHORS. 0 PAINT WALLS WITHIN ROOM AND NON—ROOM SIDE OF NEW PARTITION. PAINT TYPE AND COLOR TO BE SELECTED BY FACILITIES DEPARTMENT TO MATCH EXISTING PAINT TYPES AND COLOR SCHEMES. 0 PAINT UNDERSIDE OF EXPOSED CONCRETE SLAB ABOVE. PAINT TYPE AND COLOR TO BE SELECTED BY FACILITIES DEPARTMENT TO MATCH EXISTING PAINT TYPES AND COLOR SCHEMES. 0 PROVIDE 3'—O" x 7'-0" x 1-3/4" FLUSH HOLLOW METAL DOOR AND FRAME, NON RATED. PAINT DOOR AND FRAME. PROVIDE HARDWARE AS FOLLOWS: 3 HINGES, STANLEY FBB179 4-1/2 x 4-1/2 1 DOOR CLOSER, SARGENT SERIES 35 1 LOCKSET, SARGENT HARMONY SERIES SARGENT LOCKSET, 8200 SERIES H1, ACCOMMODATE 7 PIN INTERCHANGEABLE BEST CORE. MORTISE LOCK ALL LOCKS TO BE STOREROOM LOCKS (04) FAIL SECURE STRIKES: PROVIDE WROUGHT BOXES AND STRIKES WITH PROPER LIP LENGTH TO PROTECT TRIM BUT NOT TO PROTECT MORE THAN 1/8" BEYOND TRIM, FRAME OR INACTIVE LEAF. WHERE REQUIRED, PROVIDE OPEN BACK STRIKE AND PROTECTED TO ALLOW PRACTICAL AND SECURE OPERATION. HARMONY LOCKSETS TO BE INSTALLED BY A CERTIFIED INSTALLER. HARMONY LOCKSETS TO BE INSTALLED BY A CERTIFIED INSTALLER. 1 KEEDEX PART NO. K—DL38A24 DOOR TO FRAME POWER TRANSFER FLEX CONDUIT. 1 McKINNEY ELECTROLYNX RETROFIT CABLE FOR THE DOOR FRAME. SIZE 15'-2". 2 KICKPLATES, 8" x DOOR WIDTH -2", ROCKWOOD 3 RUBBER SILENCERS, GLYNN JOHNSON #64 1 DOOR SWEEP, PEMKO #293100CNB, CLEAR ANODIZED ALUMINUM WITH GRAY NYLON BRUSH INSERT. ALL HARDWARE TO MATCH US10 SATIN BRONZE FINISH. SEE DRAWING A4 FOR DETAIL OD DOOR FRAME IN STUD WALL. PROVIDE PARTITION. 3-5/8" 18 GAUGE METAL STUDS, 16" ON CENTER. 5/8" TYPE X GYPSUM WALL BOARD ON EACH SIDE. PROVIDE 3" ACOUSTIC BATT INSULATION BETWEEN STUDS. PARTITION TO EXTEND TO AND BE SEALED TO UNDERSIDE OF STRUCTURE ABOVE, APPROXIMATELY 8'-11". FIT GYPSUM WALL BOARD AROUND EXISTING PIPES AND CONDUIT. SEAL PENETRATIONS. REMOVE EXISTING DEMOUNTABLE PARTITION/SHELVING SYSTEM AND TURN OVER TO OWNER. REMOVE EXISTING STAINLESS STEEL DRIP PAN. PROVIDE TEMPORARY SUPPORT FOR ALUMINUM CHANNELS WHICH ARE FASTENED TO PARTITION/SHELVING SYSTEM. RE—SECURE TO NEW PARTITION. PROVIDE ROOM SIGNAGE TO MATCH EXISTING BUILDING SIGNAGE. SIGN TEXT AS DIRECTED. REMOVE EXISTING WIRE MESH PARTITION AND REINSTALL AS INDICATED. REMOVE EXISTING BOOK SHELVING AND TURN OVER TO OWNER. NOTE: REFER TO DRAWING A4 FOR DETAILS AND SCHEDULES AS APPLICABLE. HVAC 8c SPRINKLER SYSTEM CONSTRUCTION KEYED NOTES: Mt PROVIDE NEW CHILLED WATER FAN COIL UNIT. REFER TO DRAWING M4 FOR UNIT SCHEDULE. 0 PROVIDE CONNECTION TO EXISTING BRANCH. PROVIDE ADDITIONAL DRY SIDEWALL SPRINKLER COVERAGE. 0 PROVIDE SPRINKLER COVERAGE FOR MTR—SBA ROOM. COORDINATE SPRINKLER LOCATION WITH LIGHTS, PANELS, CABLE TRAYS AND TELECOMUNICATION EQUIPMENT LOCATIONS. NOTE: REFER TO DRAWING M4 FOR DETAILS AND SCHEDULES AS APPLICABLE. ELECTRICAL CONSTRUCTION KEYED NOTES: E4 E5 E6 E7 ES E9 REMOVE EX. LIGHT SWITCH AND WIRING. REMOVE EX. LIGHT FIXTURE AND WIRING. PROVIDE END TERMINATION UNIT FOR LIGHTING TRACK. RE—POSITION EX. SMOKE DETECTOR. REMOVE EXISTING SURFACE METAL RACEWAY AND FEEDER CONDUITS TO FIRST ACCESSIBLE JUNCTION BOX. TAPE AND LABEL CONDUCTORS WITH NAME OF ABANDONED CIRCUIT. PROVIDE TWO 20A DUPLEX RECEPTACLES IN COMMON BOX, EACH FED FROM SEPARATE CIRCUIT. PROVIDE ONE 20A DUPLEX RECEPTACLE. CONNECT TO EX. BRANCH CIRCUIT IN ROOM WHICH PREVIOUSLY FED SURFACE METAL RACEWAY. PROVIDE TMGB PER DETAIL ON DRAWING E4. PROVIDE NEW LIGHT FIXTURES PER SCHEDULE ON DRAWING E4. PROVIDE NEW LIGHT SWITCH, CONNECT TO EX. LIGHT CIRCUIT IN ROOM. PROVIDE EM FIXTURE, CONNECT TO UNSWITCHED LEG OF LIGHT CIRCUIT WHICH FEEDS ROOM. PROVIDE NEW DUPLEX RECEPTACLE AT 24" AFF. EXTEND EXISTING FIRE ALARM CIRCUIT(S) TO NEW SMOKE DETECTOR. SMOKE DETECTOR SHALL BE INSTALLED AT HIGHEST POINT IN THE CEILING IN THE POCKET AREA. PROVIDE ALL SHUT DOWNS, TIE—INS AND VERIFICATIONS OF EXISTING ADDRESSABLE SYSTEM TO ENSURE THAT THE FACP CAN SUPPORT NEW DEVICES. CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR TESTING, REPROGRAMMING AND MODIFICATION TO EXISTING FIRE ALARM PANEL AND REMOTE ANNUNCIATORS TO SHOW NEW DEVICE(S). PROVIDE CIRCUIT FOR ACCESS CONTROL SYSTEM READER INTERFACE MODULE AND ASSOCIATED DOOR LOCK. REMOVE AND RE—POSITION EX. LIGHT SWITCH ON RELOCATED WIRE MESH PARTITION. NOTE: REFER TO DRAWING E4 FOR DETAILS AND SCHEDULES AS APPLICABLE. GENERAL NOTES: A. REFER TO DRAWING AMEP—GEN FOR GENERAL NOTES. B. REFER TO DRAWING M2 FOR CONTINUATION AND ADDITIONAL COORDINATION REQUIREMENTS. C. REFER TO DRAWING T3—SBA FOR ADDITIONAL COORDINATION REQUIREMENTS. KEY PLAN J:\PROJECTS-Ithaca\2011\11103 CORNELL - NCP\Olin Library 2047\CAD\11103-2047--T3-SB.dwg SCALES ON THIS DRAWING ACCURATE \&HEN PLOTTED TO: ARCH El (30X42 IN.) MAI MPARCHITECHNOLOGY, 115 METRO PHONE: LLC www.archi-technology.com PARK ROCHESTER, NY 14623 585.424.1952 Fax: 585.424.4239 " 1 BEARDSLEY DESIGN ASSOCIATES Architecture, Engineering, Lantiscage Architecture, P.C. Ph 315.472.6980 5789 Widewaters Parkway Fax 315.472.3523 Dewitt, New York 13214 E- nsil B13A@Beardstey.cem I _ H V) LLI Z D J J W Z o U CLIENT: 9 0 Cornell University CONNECTIVITY PROJECT 1 -be- (ER L (ERL) EX. SPRINKLER LINES (ETR) Cfp (ETR) REMOVE EX. DRAIN PAN AND EX. DRAIN HOSE. 2BO'A� REMOVE EX. UPRIGHT SPRINKLER I I farnaalll I I i ! x-I—xx x x (ETR) I I I UP 2 BOOSA SUB -BASEMENT IDF (ROOM 2BO1A) MECHANICAL -EXISTING / REMOVALS Scale: 1/4" = i'-0" 0 2' 4' 8` X(ERL) x x (ETR) (ETR) r E2 2BO1A r E2 1 2E L x-- / x x—X---X — x x .4 UP 2BOOSA 0 (ErR) SUB -BASEMENT IDF (ROOM 2B01A) ELECTRICAL -EXISTING / REMOVALS Scale: 1/4" = 1,-0" 0 2' 4' 8' X X X X X X X X X X X X 15'-4" +/— ALIGN WITH WIRE MESH PARTITION ;2801 B X X X X X X X X X X X X X X I I I i- I I- I I i I I I I M I I 2B01A SRI RL UP XXXXXXXXXXXX X 2BOOSA I I= I I 111111111111111111 I I- I I O i I 11111111111111111 I I SUB -BASEMENT MTR-SBA (ROOM 2B01A) ARCHITECTURAL - NEW WORK Scale: 1/4" = 1'-0" 0 2' 4' 8' I I III 2 x x1 REFER TO DRAWING M2 FOR CONTINUATION EX. SPRINKLER LINES (ETR) 3/4" CHWS&R REFER TO DRAWING M2 2B01A (ETR) r -FC - X X x x X x (ETR) X x X X 2B0' REFER TO DRAWING M2 FOR CONTINUATION UP L2BoosA I SUB -BASEMENT MTR-SBA (ROOM 2B01A) MECHANICAL - NEW WORK Scale: 1/4" = 1'-0" 0 2' 4' 8' 11111111111/1/1111111111 X X x X X X X a@ X X X X ER L) PROVIDE PANEL CP TRSBA 5 CP TRSBA, 3 CRL CP TRSBA, 4 CP TRSBA, 6 X X UP X X X X X X X X X X X X X 2BOOSA ®(ETR) SUB -BASEMENT MTR-SBA (ROOM 2B01A) ELECTRICAL - NEW WORK Scale: 1/4" = 1'-0" 0 2' 4' 8' X 2 ARCHITECTURAL — GENERAL NOTES & CONSTRUCTION KEYED NOTES: A. EXISTING AND NEW PARTITIONS ON THIS PLAN ARE NOT FIRE RATED. B. REFER TO DRAWING A4 FOR DETAILS. Al PROVIDE ANTI—STATIC VINYL COMPOSITION FLOOR AND RUBBER BASE. PROVIDE RUBBER TRANSITION STRIP AT EXPOSED EDGE UNDER DOOR. 0 PROVIDE 3/4" AC PLYWOOD ON WALLS INDICATED ON THIS PLAN. PRIME AND PAINT WITH FIRE RETARDANT, LIGHT GRAY PAINT ON ALL SURFACES AND EDGES. PLYWOOD TO BE 8 FEET HIGH AND MOUNTED 6 INCHES ABOVE FLOOR. SECURE TO WALL WITH COUNTERSINK FASTENERS 24 INCHES ON CENTER MAXIMUM, EACH WAY. ANCHOR TO STUDS WITH SCREWS. ANCHOR TO CONCRETE OR MASONRY WITH EXPANSION ANCHORS. 0 PAINT WALLS WITHIN ROOM AND NON—ROOM SIDE OF NEW PARTITION. PAINT TYPE AND COLOR TO BE SELECTED BY FACILITIES DEPARTMENT TO MATCH EXISTING PAINT TYPES AND COLOR SCHEMES. 0 PAINT UNDERSIDE OF EXPOSED CONCRETE SLAB ABOVE. PAINT TYPE AND COLOR TO BE SELECTED BY FACILITIES DEPARTMENT TO MATCH EXISTING PAINT TYPES AND COLOR SCHEMES. 0 PROVIDE 3'—O" x 7'-0" x 1-3/4" FLUSH HOLLOW METAL DOOR AND FRAME, NON RATED. PAINT DOOR AND FRAME. PROVIDE HARDWARE AS FOLLOWS: 3 HINGES, STANLEY FBB179 4-1/2 x 4-1/2 1 DOOR CLOSER, SARGENT SERIES 35 1 LOCKSET, SARGENT HARMONY SERIES SARGENT LOCKSET, 8200 SERIES H1, ACCOMMODATE 7 PIN INTERCHANGEABLE BEST CORE. MORTISE LOCK ALL LOCKS TO BE STOREROOM LOCKS (04) FAIL SECURE STRIKES: PROVIDE WROUGHT BOXES AND STRIKES WITH PROPER LIP LENGTH TO PROTECT TRIM BUT NOT TO PROTECT MORE THAN 1/8" BEYOND TRIM, FRAME OR INACTIVE LEAF. WHERE REQUIRED, PROVIDE OPEN BACK STRIKE AND PROTECTED TO ALLOW PRACTICAL AND SECURE OPERATION. HARMONY LOCKSETS TO BE INSTALLED BY A CERTIFIED INSTALLER. HARMONY LOCKSETS TO BE INSTALLED BY A CERTIFIED INSTALLER. 1 KEEDEX PART NO. K—DL38A24 DOOR TO FRAME POWER TRANSFER FLEX CONDUIT. 1 McKINNEY ELECTROLYNX RETROFIT CABLE FOR THE DOOR FRAME. SIZE 15'-2". 2 KICKPLATES, 8" x DOOR WIDTH -2", ROCKWOOD 3 RUBBER SILENCERS, GLYNN JOHNSON #64 1 DOOR SWEEP, PEMKO #293100CNB, CLEAR ANODIZED ALUMINUM WITH GRAY NYLON BRUSH INSERT. ALL HARDWARE TO MATCH US10 SATIN BRONZE FINISH. SEE DRAWING A4 FOR DETAIL OD DOOR FRAME IN STUD WALL. PROVIDE PARTITION. 3-5/8" 18 GAUGE METAL STUDS, 16" ON CENTER. 5/8" TYPE X GYPSUM WALL BOARD ON EACH SIDE. PROVIDE 3" ACOUSTIC BATT INSULATION BETWEEN STUDS. PARTITION TO EXTEND TO AND BE SEALED TO UNDERSIDE OF STRUCTURE ABOVE, APPROXIMATELY 8'-11". FIT GYPSUM WALL BOARD AROUND EXISTING PIPES AND CONDUIT. SEAL PENETRATIONS. REMOVE EXISTING DEMOUNTABLE PARTITION/SHELVING SYSTEM AND TURN OVER TO OWNER. REMOVE EXISTING STAINLESS STEEL DRIP PAN. PROVIDE TEMPORARY SUPPORT FOR ALUMINUM CHANNELS WHICH ARE FASTENED TO PARTITION/SHELVING SYSTEM. RE—SECURE TO NEW PARTITION. PROVIDE ROOM SIGNAGE TO MATCH EXISTING BUILDING SIGNAGE. SIGN TEXT AS DIRECTED. REMOVE EXISTING WIRE MESH PARTITION AND REINSTALL AS INDICATED. REMOVE EXISTING BOOK SHELVING AND TURN OVER TO OWNER. NOTE: REFER TO DRAWING A4 FOR DETAILS AND SCHEDULES AS APPLICABLE. HVAC 8c SPRINKLER SYSTEM CONSTRUCTION KEYED NOTES: Mt PROVIDE NEW CHILLED WATER FAN COIL UNIT. REFER TO DRAWING M4 FOR UNIT SCHEDULE. 0 PROVIDE CONNECTION TO EXISTING BRANCH. PROVIDE ADDITIONAL DRY SIDEWALL SPRINKLER COVERAGE. 0 PROVIDE SPRINKLER COVERAGE FOR MTR—SBA ROOM. COORDINATE SPRINKLER LOCATION WITH LIGHTS, PANELS, CABLE TRAYS AND TELECOMUNICATION EQUIPMENT LOCATIONS. NOTE: REFER TO DRAWING M4 FOR DETAILS AND SCHEDULES AS APPLICABLE. ELECTRICAL CONSTRUCTION KEYED NOTES: E4 E5 E6 E7 ES E9 REMOVE EX. LIGHT SWITCH AND WIRING. REMOVE EX. LIGHT FIXTURE AND WIRING. PROVIDE END TERMINATION UNIT FOR LIGHTING TRACK. RE—POSITION EX. SMOKE DETECTOR. REMOVE EXISTING SURFACE METAL RACEWAY AND FEEDER CONDUITS TO FIRST ACCESSIBLE JUNCTION BOX. TAPE AND LABEL CONDUCTORS WITH NAME OF ABANDONED CIRCUIT. PROVIDE TWO 20A DUPLEX RECEPTACLES IN COMMON BOX, EACH FED FROM SEPARATE CIRCUIT. PROVIDE ONE 20A DUPLEX RECEPTACLE. CONNECT TO EX. BRANCH CIRCUIT IN ROOM WHICH PREVIOUSLY FED SURFACE METAL RACEWAY. PROVIDE TMGB PER DETAIL ON DRAWING E4. PROVIDE NEW LIGHT FIXTURES PER SCHEDULE ON DRAWING E4. PROVIDE NEW LIGHT SWITCH, CONNECT TO EX. LIGHT CIRCUIT IN ROOM. PROVIDE EM FIXTURE, CONNECT TO UNSWITCHED LEG OF LIGHT CIRCUIT WHICH FEEDS ROOM. PROVIDE NEW DUPLEX RECEPTACLE AT 24" AFF. EXTEND EXISTING FIRE ALARM CIRCUIT(S) TO NEW SMOKE DETECTOR. SMOKE DETECTOR SHALL BE INSTALLED AT HIGHEST POINT IN THE CEILING IN THE POCKET AREA. PROVIDE ALL SHUT DOWNS, TIE—INS AND VERIFICATIONS OF EXISTING ADDRESSABLE SYSTEM TO ENSURE THAT THE FACP CAN SUPPORT NEW DEVICES. CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR TESTING, REPROGRAMMING AND MODIFICATION TO EXISTING FIRE ALARM PANEL AND REMOTE ANNUNCIATORS TO SHOW NEW DEVICE(S). PROVIDE CIRCUIT FOR ACCESS CONTROL SYSTEM READER INTERFACE MODULE AND ASSOCIATED DOOR LOCK. REMOVE AND RE—POSITION EX. LIGHT SWITCH ON RELOCATED WIRE MESH PARTITION. NOTE: REFER TO DRAWING E4 FOR DETAILS AND SCHEDULES AS APPLICABLE. GENERAL NOTES: A. REFER TO DRAWING AMEP—GEN FOR GENERAL NOTES. B. REFER TO DRAWING M2 FOR CONTINUATION AND ADDITIONAL COORDINATION REQUIREMENTS. C. REFER TO DRAWING T3—SBA FOR ADDITIONAL COORDINATION REQUIREMENTS. KEY PLAN J:\PROJECTS-Ithaca\2011\11103 CORNELL - NCP\Olin Library 2047\CAD\11103-2047--T3-SB.dwg SCALES ON THIS DRAWING ACCURATE \&HEN PLOTTED TO: ARCH El (30X42 IN.) MAI MPARCHITECHNOLOGY, 115 METRO PHONE: LLC www.archi-technology.com PARK ROCHESTER, NY 14623 585.424.1952 Fax: 585.424.4239 " 1 BEARDSLEY DESIGN ASSOCIATES Architecture, Engineering, Lantiscage Architecture, P.C. Ph 315.472.6980 5789 Widewaters Parkway Fax 315.472.3523 Dewitt, New York 13214 E- nsil B13A@Beardstey.cem N d" o N >-- Q ›- ce z m F.. -.4Q J U Z Q 0 II H V) LLI Z D J J W Z o U CLIENT: 9 0 Cornell University CONNECTIVITY PROJECT ®.s NETWORK _ _r. a CD 06/29/12 CONSTRUCTION DOCUMENTS 100 DD 05/17/12 100% DD SUBMISSION 50 DD 50% DD SUBMISSION 20 SD 20% SD SUBMISSION PSD 08/05/11 PRELIMINARY SD MARK DATE DESCRIPTION CONSTRUCTION DOCUMENTS ISSUE DATE: 06/29/12 ,s OF NEwy co kl` NtiN c,�o ct- ,SII <.?),063153 ' c;,.., s�oNP�e AT PROJECT NO: 11.103-2047 OWNER PROJECT NO: 754 DRAWN BY: PKB CHECKED BY: JLB PROJECT MANAGER: GHS SHEET TITLE: MTRUSBA PARTIAL PLANS AND KEYNOTES AMEP-SBA 1 GENERAL NOTES FOR ALL TRADES: A. REFER TO DRAWING "T—GEN" FOR PROJECT NOTES AND ABBREVIATIONS APPLICABLE TO ALL DRAWINGS AND CONTRACTS. REFER TO TABLES ON THIS PAGE FOR DRAWING SYMBOLS AND ABBREVIATIONS PER TRADE. . REFER TO AMEP—xx DRAWINGS FOR GENERAL NOTES AND KEYED NOTES SPECIFIC TO TRADE. C. THIS INFORMATION REPRESENTS EXISTING CONDITIONS BASED ON ORIGINAL DRAWINGS AND OBSERVED SITE CONDITIONS. NOT ALL ELECTRICAL/MECHANICAL EQUIPMENT IS SHOWN. THE CONTRACTOR SHALL FIELD VERIFY EXACT ROUTING, DIMENSIONS AND QUANTITIES. . REFER TO MECHANICAL, ELECTRICAL AND COMMUNICATION DRAWINGS FOR ADDITIONAL DEMOLITION AND RENOVATION WITHIN THE INDICATED WORK AREAS. . REFER TO T2—x.CA_CP DRAWINGS FOR CEILING ACCESS PANEL LOCATIONS. • REFER TO DRAWING T3—xx DRAWINGS FOR ADDITIONAL COORDINATION REQUIREMENTS. • GENERAL CONSTRUCTION CONTRACTOR SHALL PERFORM ALL WORK AS SHOWN ON AMEP DRAWINGS, UNLESS NOTED OTHERWISE. REFER TO SPECIFICATIONS 011x00 FOR ADDITIONAL INFORMATION. . REFER TO THE PROJECT MANUAL/TECHNICAL SPECIFICATION SECTIONS FOR ADDITIONAL PRODUCT AND/OR EXECUTION REQUIREMENTS TO SUPPLEMENT INFORMATION CONTAINED ON THE DRAWINGS. CUTTING AND PATCHING OF OPENINGS IN EXISTING BUILDING CONSTRUCTION SHALL BE DONE IN A MANNER WHICH DOES NOT IMPAIR THE STRUCTURAL INTEGRITY OF THE CONSTRUCTION AND MAINTAINS ALL REQUIRED FIRE RATINGS. PATCHING SHALL INCLUDE ALL OPENINGS LEFT IN EXISTING CONSTRUCTION DUE TO DEMOLITION WORK. ALL PATCHED SURFACES ARE TO BE RESTORED AS CLOSELY AS POSSIBLE TO THE ORIGINAL CONDITIONS. ALL PATCHED AREAS REQUIRING PAINT SHALL RECEIVE TWO PRIMER COATS AND TWO FINISH COATS. MATERIALS USED FOR PATCHING SHALL MATCH EXISTING ADJACENT MATERIALS IN BOTH TYPE AND QUALITY. NEW ELECTRICAL AND MECHANICAL SYSTEMS WHICH PENETRATE NEW AND EXISTING FIRE RATED FLOORS, WALLS AND OTHER ASSEMBLIES SHALL BE FIRESTOPPED. IN AREAS ACCESSIBLE TO THE PUBLIC, FIRESTOP SYSTEMS SHALL BE SELECTED, INSTALLED AND FINISHED TO THE QUALITY OF ADJACENT SURFACES OF BUILDING CONSTRUCTION BEING PENETRATED. REFER TO SPECIFICATION 078413 FOR ADDITIONAL INFORMATION. . ALL PLAN DIMENSIONS ARE TO FACE OF PARTITION ASSEMBLY OR FINISH SURFACE (EXCLUDING PLYWOOD BACKBOARDS). . CONTRACTOR IS TO VERIFY ALL DRAWING DIMENSIONS IN THE FIELD FOR ACCURACY. M. PROVIDE SOFT COPY SUBMITTAL(S) ON ACTUAL PRODUCTS USED. INCLUDE COPY OF APPROVED SUBMITTAL WITH CLOSE OUT DOCUMENTS (IN HARD COPY 0/M MANUAL), REFER TO SECTIONS: 013300 — SUBMITTALS; 017839 — RECORD DOCUMENTS; AND 017700 — PROJECT CLOSEOUT AS APPLICABLE. N. ANY DRILLING, CUTTING ETC. WORK THAT MAY CREATE A NUISANCE FIRE ALARM, NEEDS TO BE SCHEDULED 24 HOURS IN ADVANCE WITH CUSTOMER SERVICE FOR A FIRE PROTECTION SYSTEM SHUTDOWN. SHUTDOWN WILL BE PERFORMED BY EH&S (ENVIRONMENTAL HEALTH AND SAFETY) STAFF. CONTRACTOR WILL NOT DISABLE ANY FIRE PROTECTION EQUIPMENT WITHOUT EH&S APPROVAL/ASSISTANCE. 0. ALL NEW SMOKE DETECTORS AND OTHER FIRE ALARM INITIATION/NOTIFICATION DEVICES WILL NEED TO BE TESTED BY EH&S AND AHJ (AUTHORITY HAVING JURISDICTION) FOR PROPER OPERATION OF DEVICE, DAMPER AND EXHAUST FAN SHUTDOWN. ARCHITECTURAL GENERAL NOTES: A. CLEAN ALL ROOMS DUST FREE FOLLOWING COMPLETION OF DEMOLITION AND PATCHING WORK. B. PROVIDE FIRESTOPPING IN ACCORDANCE WITH SPECIFICATION SECTION 078413 WHERE ITEMS (INCLUDING CABLE TRAYS, PIPES, CONDUIT, FRAMING MEMBERS AND DUCTS) PENETRATE BOTH NEW AND EXISTING FIRE RATED PARTITIONS. FIRE RATED PARTITIONS ARE INDICATED ON ARCHITECTURAL DRAWINGS. FOR SMOKE, FIRE, OR FIRE/SMOKE DAMPERS, TREAT PENETRATION IN ACCORDANCE WITH DAMPER MANUFACTURER'S PRINTED DIRECTIONS. USE OF FIRESTOPPING WILL INVALIDATE UL LISTING OF DAMPER. C. SEAL PENETRATIONS OF BOTH NEW AND EXISTING NON—RATED PARTITIONS INCLUDING CABLE TRAYS, PIPES, CONDUIT, FRAMING MEMBERS AND DUCTS. PROVIDE ELASTOMERIC SEALANT AT GYPSUM WALLBOARD PARTITIONS. PROVIDE MORTAR/GROUT FOR PIPES AND CONDUIT THROUGH MASONRY PARTITIONS. PROVIDE ELASTOMERIC SEALANT AT EXTERIOR WALLS. ( — REMOVALS INDICATED AS DASHED LINES (1) D DUCT DROP IN ELEVATION NEW WALL TYPE — REFER TO KEYED NOTES FOR CONSTRUCTION PIPING SYMBOLS (IP120 DUPLEX RECEPTACLE OUTLET, 20 AMPERE, VOLT, TOP OF BOX AT 24" AFF UNLESS OTHERWISE NOTED. ROOM NUMBER AIR FLOW ### DUCT — DOWN — POSITIVE PRESSURE DOUBLE DUPLEX RECEPTACLE OUTLET, 20 AMPERE, 120 VOLT, TOP OF BOX AT 24" AFF UNLESS OTHERWISE NOTED. AIR EXISTING DOOR TO REMAIN ® A • DOOR NUMBER (NEW OR EXISTING) 20 AMPERE, 277 VOLT, SINGLE POLE AC SWITCH, TOP OF BOX AT 48" AFF DEFINITION OF SUBSCRIPTS: 2 TWO POLE SWITCH 3 THREE WAY SWITCH 4 FOUR WAY SWITCH M FRACTIONAL HORSEPOWER, MANUAL MOTOR STARTER W/ THERMAL OVERLOADS abc LOWER CASE LETTER(S) SIGNIFY SWITCHING DESIGNATIONS, QUANTITY OF LETTERS EQUALS QUANTITY OF GANGED SWITCHES. DUCT — DOWN — NEGATIVE PRESSURE NEW DOOR AND FRAME VENT —44 NEW TO EXISTING CONNECTION i INDICATES 2—HOUR RATED SEPARATION r ®i i ,� immiFIRE ATMOSPHERIC INDICATES 1 —HOUR RATED FIRE SEPARATION ®' imit POWER PANEL CEILING ACCESS PANEL FIRE ALARM SYSTEM HEAT DETECTOR A3 DUCT — UP THRU ROOF — NEGATIVE PRESSURECA IIII1` ARCHITECTURAL SYMBOLS LEGEND Scale: NONE HVAC GENERAL NOTES: A. VERIFY ALL EXISTING CONDITIONS. EQUIPMENT LOCATIONS SHOWN ARE APPROXIMATE AND MINOR ADJUSTMENTS TO THE INSTALLATION MAY BE REQUIRED TO AVOID CONFLICTS WITH EXISTING EQUIPMENT AND APPARATUS — EXISTING BRANCH CIRCUITS ARE FROM RECORD DRAWINGS, AND MAY VARY. . FIELD VERIFY ALL EXISTING CONDITIONS AND DETERMINE THE BEST PATH FOR NEW INSTALLATIONS THAT WILL CAUSE THE LEAST DISTURBANCE TO OCCUPIED SURROUNDINGS. PATHWAYS THAT ARE ROUTED THROUGH MECHANICAL ROOMS, UTILITY ROOMS, STORAGE CLOSETS, ETC. ARE FAVORABLE TO DISTURBANCES IN OCCUPIED AREAS. C. INSTALL ALL EQUIPMENT IN STRICT CONFORMANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS AND RECOMMENDATIONS. D. COORDINATE THE WORK SHOWN ON THESE DRAWINGS WITH THE WORK OF ALL OTHER TRADES PRIOR TO THE FABRICATION OR INSTALLATION OF ANY WORK. EQUIPMENT AND DEVICES THAT CANNOT CHANGE LOCATION SHALL TAKE PRECEDENCE OVER THOSE THAT CAN CHANGE. E. THESE DRAWINGS ARE SCHEMATIC IN NATURE. PROVIDE ALL OFFSETS, HANGERS, ANCHORS, SUPPORTS, WIRING AND ACCESSORIES FOR A COMPLETE, OPERATIONAL INSTALLATION. F. WHERE CEILINGS ARE REMOVED TO ACCOMMODATE NEW TELECOM ROOMS, PROVIDE SUPPORT(S) FOR ALL REMAINING MECHANICAL PIPING, DUCTWORK, MISCELLANEOUS EQUIPMENT, ETC. NOT BEING REMOVED. ALL UNUSED EQUIPMENT & APPURTENANCES SHALL BE REMOVED AND PROPERLY DISPOSED OF. G. ALL EXISTING AND NEW PIPING, DUCTWORK, MECHANICAL EQUIPMENT IN TELECOM ROOMS SHALL BE CLEANED FREE OF DUST/DEBRIS AFTER WALL DEMOLITION AND AFTER WALL RECONSTRUCTION/PATCHING. SPRINKLER SYSTEM GENERAL NOTES: A. PROVIDE GALVANIZED STEEL PIPING TO MATCH EX. GALVANIZED STEEL PIPING. ELECTRICAL GENERAL NOTES: A. VERIFY ALL EXISTING CONDITIONS. EQUIPMENT LOCATIONS SHOWN ARE APPROXIMATE AND MINOR ADJUSTMENTS TO THE INSTALLATION MAY BE REQUIRED TO AVOID CONFLICTS WITH EXISTING EQUIPMENT AND APPARATUS — EXISTING BRANCH CIRCUITS ARE FROM RECORD DRAWINGS, AND MAY VARY. 8. FIELD VERIFY ALL EXISTING CONDITIONS AND SHALL DETERMINE THE BEST PATH FOR NEW INSTALLATIONS THAT WILL CAUSE THE LEAST DISTURBANCE TO OCCUPIED SURROUNDINGS. PATHWAYS THAT ARE ROUTED THROUGH MECHANICAL ROOMS, UTILITY ROOMS, STORAGE CLOSETS, ETC. ARE FAVORABLE TO DISTURBANCES IN OCCUPIED AREAS, ALL NEW LUMINAIRES SHALL BE INSTALLED AT A MINIMUM HEIGHT OF 9'-6" AFF UNLESS OTHERWISE NOTED. C. COORDINATE MOUNTING HEIGHT OF ALL NEW POWER OUTLETS WITH THE TELECOMMUNICATIONS SYSTEMS EQUIPMENT ELEVATION DRAWINGS/DETAILS. D. COORDINATE ALL REQUIRED POWER AND FIRE ALARM SHUTDOWNS WITH THE OWNER. PROVIDE MINIMUM 1 WEEK ADVANCE NOTICE. E. WHERE CEILINGS ARE REMOVED TO ACCOMMODATE NEW TELECOM ROOMS, PROVIDE SUPPORT(S) FOR ALL REMAINING ELECTRICAL CONDUITS, DEVICES, EQUIPMENT, ETC. NOT BEING REMOVED. ALL UNUSED EQUIPMENT SHALL BE REMOVED AND PROPERLY DISPOSED OF. F. ALL EXISTING AND NEW CONDUIT AND ELECTRICAL EQUIPMENT IN TELECOM ROOMS SHALL BE CLEANED FREE OF DUST/DEBRIS AFTER WALL DEMOLITION AND AFTER WALL RECONSTRUCTION/ PATCHING. G. PROVIDE GROUNDING IDENTIFICATION AS CALLED FOR. PROVIDE TAGS ON GROUND CONDUCTOR IN ALL SPACES AS DIRECTED AND SHOWN ON GROUNDING DETAIL. H. DURING CONSTRUCTION, PROVIDE HEAT DETECTORS IN TELECOM ROOMS. AT SUBSTANTIAL COMPLETION AND AFTER FINAL CLEANING, CHANGE HEAT DETECTOR TO SMOKE DETECTOR. ALL FIRE ALARM SYSTEM DEVICES SHALL BE TESTED BY EH&S AND AHJ FOR PROPER OPERATION OF DETECTOR, DAMPER, AND FAN SHUTDOWN. 171 0 DUCT — UP — NEGATIVE PRESSURE (1) D DUCT DROP IN ELEVATION Q Q 9 PIPING SYMBOLS (IP120 DUPLEX RECEPTACLE OUTLET, 20 AMPERE, VOLT, TOP OF BOX AT 24" AFF UNLESS OTHERWISE NOTED. (--rL— AIR FLOW ABOVE FINISH FLOOR DUCT — DOWN — POSITIVE PRESSURE DOUBLE DUPLEX RECEPTACLE OUTLET, 20 AMPERE, 120 VOLT, TOP OF BOX AT 24" AFF UNLESS OTHERWISE NOTED. AIR C ® A APD AIR PRESSURE DROP " WG 20 AMPERE, 277 VOLT, SINGLE POLE AC SWITCH, TOP OF BOX AT 48" AFF DEFINITION OF SUBSCRIPTS: 2 TWO POLE SWITCH 3 THREE WAY SWITCH 4 FOUR WAY SWITCH M FRACTIONAL HORSEPOWER, MANUAL MOTOR STARTER W/ THERMAL OVERLOADS abc LOWER CASE LETTER(S) SIGNIFY SWITCHING DESIGNATIONS, QUANTITY OF LETTERS EQUALS QUANTITY OF GANGED SWITCHES. DUCT — DOWN — NEGATIVE PRESSURE BRANCH CIRCUIT HOMERUN, SUBSCRIPT INDICATES PANELBOARD & CIRCUIT DESIGNATION, QUANTITY OF ARROWHEADS DENOTES QUANTITY OF BRANCH CIRCUITS. PROVIDE GREEN GROUND WIRE AND ONE NEUTRAL PER PHASE CONDUCTOR IN EACH CIRCUIT. PROTECT EACH CIRCUIT WITH A 20 AMPERE, 1—POLE O\'ERCURRENT DEVICE. UNLESS OTHERWISE INDICATED, MINIMUM WIRE SIZE SHALL BE #10 THHN. VENT —44 NEW TO EXISTING CONNECTION i © ATV ATMOSPHERIC FIRE ALARM SYSTEM SMOKE DETECTOR BRITISH THERMAL UNITS PER HOUR POWER PANEL COMPRESSED AIR FIRE ALARM SYSTEM HEAT DETECTOR CONCRETE DUCT — UP THRU ROOF — NEGATIVE PRESSURECA IIII1` i CHILLED WATER SUPPLY CAPPED DUCT CHILLED WATER RETURN CARD READER LOCK CHILLED WATER SUPPLY & RETURN TGB CARD READER LOCK db CD CONDENSATE DRAIN DIAMETER DN DUCT — UP THRU ROOF —POSITIVE PRESSURE 1 11 DRAWING EA SINGLE INPUT READER INTERFACE MODULE EAT SRI EDB DUCT TRANSITION FROM RECTANGULAR TO ROUND TMGB ENERGY EFFICIENCY RATIO EF WATER RETURN >a< — DUCT — UP —POSITIVE PRESSURE CHWR CHILLED DRI WATER SUPPLY & RETURN ENERGY MANAGEMENT SYSTEM ERL DUCT SIZE — FIRST FIGURE IS SIZE SHOWN CHWS&R CHILLED DE DUCT TRANSITION FROM RECTANGULAR TO RECTANGULAR ETR EXISTING TO REMAIN EWB ENTERING WET BULB (F) EWT CHILLED WATER SUPPLY EX./EXIST EXISTING CHWS EXPOSED 'F DEGREES FAHRENHEIT FLEXIBLE CONNECTION FIRE ALARM DOMESTIC COLD WATER FIRE ALARM CONTROL PANEL FCU FAN COIL UNIT FD DCW FLA FULL LOAD AMPS r.--- I-. SQUARE THROAT RADIUS ELBOW FSD COMBINATION FIRE/SMOKE DAMPER FT OR ' } GC DOMESTIC HOT WATER RETURN GPM GALLONS PER MINUTE ACOUSTICALLY LINED DUCTWORK DHR HM 4 4 HORSEPOWER DOMESTIC HOT WATER HEATING, VENTILATION & AIR CONDITIONING HWR HOT WATER RETURN HWS DHW HWS&R HOT WATER SUPPLY & RETURN IP FLEXIBLE DUCT JB JUNCTION BOX KD SQUARE TO ROUND BRANCH DUCT KW NATURAL GAS LAT LEAVING AIR TEMPERATURE (F) 1'C G LWB LEAVING WET BULB LWT LEAVING WATER TEMPERATURE (F) MAX MAXIMUM MBH WATER RETURN MCA MINIMUM CIRCUIT AMPACITY MCB MAIN CIRCUIT BREAKER VOLUME DAMPER HWR HOT 111111=HWS NC NORMALLY CLOSED WATER SUPPLY NORMALLY OPEN PD PRESSURE DROP HOT PREFINISHED PH RECTANGULAR ELBOW WITH TURNING VANES PLAS PLASTER DUCT WYE POUNDS PER SQUARE INCH PIPING PAINT TO MATCH EXISTING PW iOR SP SPRINKLER RB RUBBER BASE/SILL O PIPING RISE RL REFRIGERANT LIQUID RS REFRIGERANT SUCTION RRT RUBBER REDUCER STRIP THRESHOLD SA SUPPLY AIR SC PIPING DROP SRI SINGLE READER INTERFACE CARD READER ST 0 TGB TELECOMMUNICATIONS GROUNDING BUSBAR RADIUS ELBOW (MIN R/W = 1.5) Cps DIGITAL SENSOR TYPICAL V CAPPED PIPE VAV ril VB VINYL BASE VCT 1 VD 0 THERMOSTAT VELOCITY WD CEILING GRILLE (G) REGISTER (R) WMP DIRECTION OF FLUID FLOW XFMR \ PITCH PIPING DOWN OG THERMOSTAT OR SENSOR WITH GUARD DN SHUT OFF VALVE CEILING DIFFUSER (D) O H D CEILING EA SPRINKLER ( ) • SPRINKLER HEAD (ABOVE CEILING) nry 1 nl I /ER ORI lMr'wPf I!T / � SPRINKLER HEAD DRY SIDEWALL �• OF DISCONNECT R DUCT RISE IN ELEVATIONN;411POINT MECHANICAL SYMBOLS LEGEND Scale: NONE ELECTRICAL SYMBOLS LEGEND Scale: NONE ABBREVIATION LIGHTING FIXTURE, CEILING MOUNTED (1) SINGLE RECEPTACLE OUTLET, 20 AMPERE DEDICATED U.P.S. CIRCUIT, 120 VOLT, TOP OF BOX AT 24" AFF SURFACE MOUNTED ON PLYWOOD UNLESS OTHERWISE NOTED. D ❑ O Q Q 9 LIGHTING FIXTURE, WALL MOUNT (IP120 DUPLEX RECEPTACLE OUTLET, 20 AMPERE, VOLT, TOP OF BOX AT 24" AFF UNLESS OTHERWISE NOTED. ACCESS DOOR LIGHTING FIXTURE, FLUORESCENT, CEILING MOUNTED, INDUSTRIAL/STRIP ABOVE FINISH FLOOR Ea DOUBLE DUPLEX RECEPTACLE OUTLET, 20 AMPERE, 120 VOLT, TOP OF BOX AT 24" AFF UNLESS OTHERWISE NOTED. AHU EM LIGHTING FIXTURE 1S7 --S; ALUMINUM SILL APD AIR PRESSURE DROP " WG 20 AMPERE, 277 VOLT, SINGLE POLE AC SWITCH, TOP OF BOX AT 48" AFF DEFINITION OF SUBSCRIPTS: 2 TWO POLE SWITCH 3 THREE WAY SWITCH 4 FOUR WAY SWITCH M FRACTIONAL HORSEPOWER, MANUAL MOTOR STARTER W/ THERMAL OVERLOADS abc LOWER CASE LETTER(S) SIGNIFY SWITCHING DESIGNATIONS, QUANTITY OF LETTERS EQUALS QUANTITY OF GANGED SWITCHES. • — PP1 /3 BRANCH CIRCUIT HOMERUN, SUBSCRIPT INDICATES PANELBOARD & CIRCUIT DESIGNATION, QUANTITY OF ARROWHEADS DENOTES QUANTITY OF BRANCH CIRCUITS. PROVIDE GREEN GROUND WIRE AND ONE NEUTRAL PER PHASE CONDUCTOR IN EACH CIRCUIT. PROTECT EACH CIRCUIT WITH A 20 AMPERE, 1—POLE O\'ERCURRENT DEVICE. UNLESS OTHERWISE INDICATED, MINIMUM WIRE SIZE SHALL BE #10 THHN. $ MD MOTION DETECTOR, WALL SWITCH TYPE 0 JUNCTION BOX, SURFACE MOUNT ��--� DISCONNECT SWITCH 0S FIRE ALARM SYSTEM SMOKE DETECTOR BRITISH THERMAL UNITS PER HOUR POWER PANEL HD FIRE ALARM SYSTEM HEAT DETECTOR CONCRETE PANEL CONCRETE MASONRY UNIT CHWS CHILLED WATER SUPPLY TELECOMMUNICATIONS GROUNDING BUS BAR CHILLED WATER RETURN CARD READER LOCK CHILLED WATER SUPPLY & RETURN TGB CARD READER LOCK db CRL DIA, 0 DIAMETER DN TELECOMMUNICATIONS MAIN GROUNDING BUS BAR DWG DRAWING EA SINGLE INPUT READER INTERFACE MODULE EAT SRI EDB ENTERING DRY BULB TMGB ENERGY EFFICIENCY RATIO EF EXHAUST FAN EH&S — EFF DUAL INPUT READER INTERFACE MODULE EM DRI EMS ENERGY MANAGEMENT SYSTEM ERL — ElDOOR CONTACT (POSITION SWITCH) ELECTRICAL SYMBOLS LEGEND Scale: NONE ABBREVIATION DESCRIPTION A AMPERE AC AIR CONDITIONING ACCU AIR COOLED CONDENSING UNIT AD ACCESS DOOR AFF ABOVE FINISH FLOOR AHJ AUTHORITY HAVING JURISDICTION AHU AIR HANDLING UNIT AL ALUMINUM SILL APD AIR PRESSURE DROP " WG APPROX APPROXIMATELY AT ALUMINUM THRESHOLD AWG AMERICAN WIRE GAUGE BTU BRITISH THERMAL UNIT BOP BOTTOM OF PIPE BTUH BRITISH THERMAL UNITS PER HOUR CFM CUBIC FEET PER MINUTE CONC CONCRETE CMU CONCRETE MASONRY UNIT CHWS CHILLED WATER SUPPLY CHWR CHILLED WATER RETURN CHWS&R CHILLED WATER SUPPLY & RETURN CRL CARD READER LOCK db DRY BULB (F) DIA, 0 DIAMETER DN DOWN DWG DRAWING EA EXHAUST AIR EAT ENTERING AIR TEMPERATURE EDB ENTERING DRY BULB EER ENERGY EFFICIENCY RATIO EF EXHAUST FAN EH&S ENVIRONMENTAL HEALTH & SAFETY EFF EFFICIENCY EM EMERGENCY EMS ENERGY MANAGEMENT SYSTEM ERL EXISTING TO BE RELOCATED ERM EXISTING TO BE REMOVED ESP EXTERNAL STATIC PRESSURE ETR EXISTING TO REMAIN EWB ENTERING WET BULB (F) EWT ENTERING WATER TEMPERATURE (F) EX./EXIST EXISTING EXP EXPOSED 'F DEGREES FAHRENHEIT FA FIRE ALARM FACP FIRE ALARM CONTROL PANEL FCU FAN COIL UNIT FD FIRE DAMPER FLA FULL LOAD AMPS FPM FEET PER MINUTE FSD COMBINATION FIRE/SMOKE DAMPER FT OR ' FEET (OF HEAD) GC GENERAL CONSTRUCTION CONTRACTOR GPM GALLONS PER MINUTE GYP GYPSUM BOARD HM HOLLOW METAL HP HORSEPOWER HVAC HEATING, VENTILATION & AIR CONDITIONING HWR HOT WATER RETURN HWS HOT WATER SUPPLY HWS&R HOT WATER SUPPLY & RETURN IP INTERIOR PAINT JB JUNCTION BOX KD KNOCK—DOWN FRAME KW KILOWATTS LAT LEAVING AIR TEMPERATURE (F) LDB LEAVING DRY BULB LWB LEAVING WET BULB LWT LEAVING WATER TEMPERATURE (F) MAX MAXIMUM MBH THOUSAND BTUH MCA MINIMUM CIRCUIT AMPACITY MCB MAIN CIRCUIT BREAKER MDP MAIN DISTRIBUTION PANEL MIN MINIMUM NC NORMALLY CLOSED NO NORMALLY OPEN PD PRESSURE DROP PF PREFINISHED PH PHASE PLAS PLASTER PSI POUNDS PER SQUARE INCH PT PAINT TO MATCH EXISTING PW PLYWOOD RA RETURN AIR RB RUBBER BASE/SILL RF RETURN FAN RL REFRIGERANT LIQUID RS REFRIGERANT SUCTION RRT RUBBER REDUCER STRIP THRESHOLD SA SUPPLY AIR SC SEALED CONCRETE SRI SINGLE READER INTERFACE CARD READER ST STAIN TO MATCH EXISTING TGB TELECOMMUNICATIONS GROUNDING BUSBAR TMGB TELECOMMUNICATIONS MAIN GROUNDING BUSBAR TYP TYPICAL V VOLT VAV VARIABLE AIR VOLUME VB VINYL BASE VCT VINYL COMPOSITION TILE VD VOLUME DAMPER VEL VELOCITY WD WOOD WMP WIRE MESH PARTITION XFMR TRANSFORMER ABBREVIATIONS Scale: NONE J:\PROJECTS—Ithaca\2011 \ 11103 CORNELL — NCP\Olin Library 2047\CAD\ 1 1 103-2047--AMEP—GEN.dwa SCALES ON THIS DRAWING ACCURATE WHEN PLOTTED TO: ARCH El (30X42 IN.) rAmi RPARCHITECHNOLOGY, 115 METRO PHONE: LLC www.archi-technology.com PARK ROCHESTER, NY 14623 585.424.1952 Fax: 585.424.4239 1MBEARDSLEY DESIGN Architecture, Engineering, Landscape Architecture, P.C. Ph 315.472.69110 5789 Widewaters Parkway Fax 315_472.3523 Dewitt, New York 13214 E -mall BDAOBeardsley_cam i..L N 0 N ›— fit Q >-- Ct z CO 1--4 '<e __I U Z Q I --I 1 J O F--� (!) W Z D J Lll o U CLIENT: b‘, Nabi©(b Cornell University PROJECT NETWORK __ CONNECTIVITY CD 06/29/12 CONSTRUCTION DOCUMENTS 100 DD 05/17/12 100% DD SUBMISSION 50 DD 50% DD SUBMISSION 20 SD 10/07/11 20% SD SUBMISSION PSD 08/26/11 PRELIMINARY SD MARK DATE DESCRIPTION CONSTRUCTION DOCUMENTS ISSUE DATE: 06/29/ 1 2 ,c.,0F NFA .sP��pt40N.C(4 F©p pg3153 . #6' RAF: sioW" AT PROJECT NO: 11103-2047 OWNER PROJECT NO: 754 DRAWN BY: PKB CHECKED BY: JLB PROJECT MANAGER: GHS SHEET TITLE: GENERAL SYMBOLS ABBREVIATIONS (AMEP NOTES, AND SERIES) PLOT BY: pbarrie w a) w F- 0 0 3- 111•1111111011 I f M I I I I= f l r� goo LJ 625 600U8 L,, i /I — / 1 L_! SIXTH FLOOR (ROOM 625) ARCHITECTURAL -EXISTING / DEMO Scale: 1/4" = 1'-0" 0 2' 4' 8' 4) 625 1.60OUB I I■! I I N I I SIXTH FLOOR ITR -6A (ROOM 625A) ARCHITECTURAL - NEW WORK Scale: 1/4" = 1'-0" 0 2' 4' 8' EX. SPRINKLER ONES (ETR) (ETR) -O (ETR) T 600 (ETR) 625 --*(ETR) (ET 600U81 EX. SPRINKLER LINES (ETR) REMOVE EX. SPRINKLER - AND ARM—OVER BACK TO BRANCH LI NE. SIXTH FLOOR (ROOM 625) MECHANICAL -EXISTING / REMOVALS Scale: 1/4" = 1'-0" 0 2' 4' 8' PROVIDE MOUNTING SPACER TO ALLOW FOR INSTALLATION OF CONDENSATE PIPING EX. SPRINKLER LINES (ETR) —(ETR) FC -3 1625,1; (ETR) (ETR) 625 1 (ETR) 3/4" — CONDENSATE PROVIDE CLEANOUTS .1.. AT ELBOWS 600UB 3/4" CHWS&R REFER TO DWG M2 FOR CONTINUATION SIXTH FLOOR ITR -6A (ROOM 625A) MECHANICAL - NEW WORK Scale: 1/4" = 1'-0" 0 2' 4' 8' EX. SPRINKLER LINES (ETR) ARCHITECTURAL — GENERAL NOTES 8c CONSTRUCTION KEYED NOTES: A. NEW PARTITIONS ON THIS PLAN ARE NOT FIRE RATED. EXISTING PARTITIONS AROUND DUMB WAITER SHAFT (600ED), STAIR, ELEVATOR SHAFT AND ELECTRICAL CHASE ARE 2 HOUR FIRE RATED. B. CLEAN ROOM TO PROVIDE DUST FREE ROOM UPON COMPLETION OF DEMOLITION AND PATCHING WORK. C. REFER TO DRAWING A4 FOR DETAILS AND SCHEDULES. Al PROVIDE PARTITION. 3-5/8" 18 GUAGE METAL STUDS, 16" ON CENTER. 5/8" TYPE GYPSUM WALL BOARD ON EACH SIDE. PROVIDE 3" ACOUSTIC BATT INSULATION BETWEEN STUDS. PARTITION TO EXTEND TO AND BE SEALED TO UNDERSIDE OF STRUCTURE ABOVE, APPROXIMATELY 8'-4". FIT GYPSUM WALL BOARD AROUND EXISTING PIPES AND CONDUIT. SEAL PENETRATIONS. 0 PROVIDE 3'-0" x 7'—O" x 1-3/4" FLUSH HOLLOW METAL DOOR AND FRAME, NON RATED. PAINT DOOR AND FRAME. PROVIDE HARDWARE AS FOLLOWS: 3 HINGES, STANLEY FBB179 4-1/2 x 4-1/2 1 DOOR CLOSER, SARGENT SERIES 35 1 LOCKSET, SARGENT HARMONY SERIES SARGENT LOCKSET, 8200 SERIES Hi, ACCOMMODATE 7 PIN INTERCHANGEABLE BEST CORE. MORTISE LOCK ALL LOCKS TO BE STOREROOM LOCKS (04) FAIL SECURE STRIKES: PROVIDE WROUGHT BOXES AND STRIKES WITH PROPER LIP LENGTH TO PROTECT TRIM BUT NOT TO PROTECT MORE THAN 1/8" BEYOND TRIM, FRAME OR INACTIVE LEAF. WHERE REQUIRED, PROVIDE OPEN BACK STRIKE AND PROTECTED TO ALLOW PRACTICAL AND SECURE OPERATION. HARMONY LOCKSETS TO BE INSTALLED BY A CERTIFIED INSTALLER. 1 KEEDEX PART NO. K—DL38A24 DOOR TO FRAME POWER TRANSFER FLEX CONDUIT. 1 McKINNEY ELECTROLYNX RETROFIT CABLE FOR THE DOOR FRAME. SIZE 15'-2". 1 SET DOOR CONTACTS: SENTROL 1078 FLUSH RECESSED, SENTROL 1038 SURFACE MOUNT 2 KICKPLATES, 8" x DOOR WIDTH -2", ROCKWOOD 3 RUBBER SILENCERS, GLYNN JOHNSON #64 1 DOOR SWEEP, PEMKO #293100CNB, CLEAR ANODIZED ALUMINUM WITH GRAY NYLON BRUSH INSERT. 1 DOOR STOP, WALL MOUNTED ALL HARDWARE TO MATCH US10 SATIN BRONZE FINISH. SEE DRAWING A4 FOR DETAIL OD DOOR FRAME IN STUD WALL. O PAINT WALLS WITHIN ROOM AND NON—ROOM SIDE OF NEW PARTITION. PAINT TYPE AND COLOR TO BE SELECTED BY FACILITIES DEPARTMENT TO MATCH EXISTING PAINT TYPES AND COLOR SCHEMES. A4 PAINT UNDERSIDE OF EXPOSED CONCRETE SLAB ABOVE. PAINT TYPE AND COLOR TO BE SELECTED BY FACILITIES DEPARTMENT TO MATCH EXISTING PAINT TYPES AND COLOR SCHEMES. 0 PROVIDE 3/4" AC PLYWOOD ON WALLS INDICATED ON THIS PLAN. PRIME AND PAINT WITH FIRE RETARDANT, LIGHT GRAY PAINT ON ALL SURFACES AND EDGES. PLYWOOD TO BE 8 FEET HIGH AND MOUNTED 6 INCHES ABOVE FLOOR. SECURE TO WALL WITH COUNTERSINK FASTENERS 24 INCHES ON CENTER MAXIMUM, EACH WAY. ANCHOR TO STUDS WITH SCREWS. ANCHOR TO CONCRETE OR MASONRY WITH EXPANSION ANCHORS. 0 REMOVE EXISTING LIBRARY SHELVING WITH CARE AND TURN OVER TO OWNER. 0 PROVIDE ROOM SIGNAGE TO MATCH EXISTING BUILDING SIGNAGE. SIGN TEXT AS DIRECTED. 0 PROVIDE TWO 3'-0" x 7'-0" x 1-3/4" FLUSH HOLLOW METAL DOORS AND FRAME, NON RATED. HARDWARE AS FOLLOWS: (6)HINGES, STANLEY FBB179 4-1/2 x 4-1/2 1CARD READER LOCKSET, SARGENT HARMONY 8200 SERIES, ACCOMMODATE 7 PIN INTERCHANGEABLE BEST CORE. FUNCTION, FAIL SECURE. LOCKSET TO BE INSTALLED BY MANUFACTURER CERTIFIED INSTALLER. 2 MANUAL FLUSHBOLTS, TOP AND BOTTOM ON INACTIVE LEAF 1 POWER TRANSFER, KEEDEX PART # K—DL38A24 1 SET DOOR CONTACTS, SENTROL 1078 FLUSH RECESSED 1 ASTRAGAL, 2" WIDE PAINTED STEEL BLUE. 2 DOOR CLOSER, SARGENT SERIES 351 2 KICKPLATES, 8" DOOR WIDTH -2" ROCKWOOD 2 RUBBER SILENCERS, GLYNN JOHNSON #64 2 DOOR SWEEP, PEMKO #293100CNB, CLEAR ANODIZED ALUMINUM WITH GREY NYLON BRUSH INSERT PAINT DOOR AND FRAME. PROVIDE STOREROOM HVAC 8c SPRINKLER SYSTEM CONSTRUCTION KEYED NOTES: 0 PROVIDE HIGH SIDEWALL CHILLED WATER FAN COIL UNIT. REFER TO DRAWING M2. REFER TO DRAWING M4 FOR UNIT SCHEDULE. 0 PROVIDE CONNECTION TO EXISTING BRANCHLINE. PROVIDE ADDITIONAL DRY SIDEWALL SPRINKLER COVERAGE FOR ROOM 625A. PROVIDE CALCULATIONS AND SHOP DRAWINGS IN ACCORDANCE WITH SPECIFICATION SECTION 21 13 13. COORDINATE SPRINKLER LOCATION WITH LIGHTS, PANELS, CABLE TRAYS AND TELECOMMUNICATION EQUIPMENT LOCATIONS. 0 PROVIDE PLUG IN OUTLET LEFT BY REMOVALS. 0 PROVIDE WALL MOUNTED CONDENSATE PUMP. PROVIDE INDIRECT CONNECTION FROM FC -3 CONDENSATE TO CONDENSATE PUMP. REFER TO DWG. M4 FOR DETAIL. 0 RELOCATE EXISTING SPRINKLER BRANCH LINE AS REQUIRED BY NEW WALL CONSTRUCTION. 0 PROVIDE CONNECTION TO EXISTING MAIN. PROVIDE ADDITIONAL SPRINKLER COVERAGE. PROVIDE CALCULATIONS AND SHOP DRAWINGS IN ACCORDANCE WITH SPECIFICATION SECTION 21 13 13. NOTE: REFER TO DRAWING M4 FOR DETAILS AND SCHEDULES AS APPLICABLE. EX. POWER PANEL P1 EX. AIR SAMPLING SMOKE DETECTION CONTROL PANEL VESDA SMOKE ALARM SYSTEM PIPING (ETR) T� c)(ETR) 625 600U6 T I VESDA SMOKE (ETR) ALARM — SYSTEM PIPING (ETR) (ETR) O(ETR) SIXTH FLOOR (ROOM 625) ELECTRICAL -EXISTING / REMOVALS Scale: 1/4" = 1'-0" 0 2' 4' 8' EX. POWER PANEL P1 EX. AIR SAMPLING SMOKE DETECTION CONTROL PANEL FC -3 +CP TR6A, 4 VESDA SMOKE ALARM SYSTEM PIPING (ETR) CP TR6A, 5 PROVIE POWERP TR6A, (ETR) O(ETR) 625 CP TR6A, 3 VESDA SMOKE ALARM SYSTEM PIPING (ETR) ETR) (ETR) 0(ETR) SIXTH FLOOR ITR -6A (ROOM 625A) ELECTRICAL - NEW WORK NEL 1,2 Scale: 1/4" = 1'-0" 0 2' 4' 8' ELECTRICAL CONSTRUCTION KEYED NOTES: REMOVE EX. LIGHT FIXTURE AND WIRING. PROVIDE END TERMINATION UNIT FOR LIGHTING TRACK. PROVIDE TGB PER DETAIL ON DRAWING E4. PROVIDE NEW DUPLEX RECEPTACLE AT 24" AFF UNLESS NOTED OTHERWISE. PROVIDE 20A DUPLEX RECEPTACLE AT 24" AFF. FEED FROM EX. ELECRICAL PANEL P1 IN ADJACENT ROOM, SPARE CIRCUIT #1. PROVIDE TWO 20A DUPLEX RECEPTACLES IN COMMON BOX, EACH FED FROM SEPARATE CIRCUIT. MOUNT AT 24" AFF. PROVIDE NEW LIGHT SWITCH, CONNECT TO EX. LIGHTING BRANCH CIRCUIT IN ROOM. PROVIDE NEW LIGHT FIXTURE PER SCHEDULE ON DRAWING E4. PROVIDE EM LIGHT FIXTURE, CONNECT TO UNSWITCHED LEG OF LIGHT CIRCUIT WHICH FEEDS ROOM. EXTEND EXISTING FIRE ALARM CIRCUIT TO NEW SMOKE DETECTOR. PROVIDE ALL SHUT DOWNS, TIE—INS AND VERIFICATIONS OF EXISTING ADDRESSABLE SYSTEM TO ENSURE THAT THE FACP CAN SUPPORT NEW DEVICES. CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR TESTING, REPROGRAMMING AND MODIFICATION TO EXISTING FIRE ALARM PANEL AND REMOTE ANNUNCIATORS TO SHOW NEW DEVICE(S). PROVIDE CIRCUIT FOR ACCESS CONTROL SYSTEM READER INTERFACE MODULE AND ASSOCIATED DOOR LOCK. DURING CONSTRUCTION, WHILE PARTICULATE IS BEING GENERATED, THE SAMPLING PORTS OF THE VESDA SYSTEM SHALL BE TEMPORARILY COVERED. RECTIFICATION OF TROUBLE SIGNALS GENERATED BY THE VESDA SYSTEM SHALL BE THE CONTRACTORS RESPONSIBILITY. NOTE: REFER TO DRAWING E4 FOR DETAILS AND SCHEDULES AS APPLICABLE. GENERAL NOTES: A. REFER TO DRAWING AMEP—GEN. B. REFER TO DRAWING M2 FOR CONTINUATION AND ADDITIONAL COORDINATION REQUIREMENTS. C. REFER TO DRAWING T3 -6A FOR ADDITIONAL COORDINATION REQUIREMENTS. 1TR-6A (RM. 625A) KEY PLAN J:\PROJECTS-Ithaca12011111103 CORNELL - NCP\Olin Library 2047\CAD\11103-2047--T3-6.dwg SCALES ON THIS DRAWING ACCURATE WHEN PLOTTED TO: ARCH El (30X42 IN.) dPiri 4 dime 115 METRO PHONE: ARCHITECHNOLOGY, LLC www.archi-technology .corn PARK ROCHESTER, NY 14623 585.424.1952 Fax: 585.424.4239 I iii 4 BEARDSLEY DESIGN ASSOCIATES Architecture, 5789 Widewaters Dewitt, Engineering, Landscape Architecture, P.C. Ph 315.472.6980 Parkway Fax 315.472.3523 New York 13214 E-mail B12AEBearrlsleq_nam CORNELL UNIVERSITY OLIN LIBRARY - 2047 ITHACA, NY CLIENT: Cornell University CONNECTIVITY PROJECT ® NETWORK (r®'x9< CD 06/29/12 CONSTRUCTION DOCUMENTS 100 DD 05/17/12 100% DD SUBMISSION 50 DD 50% DD SUBMISSION 20 SD 10/07/11 20% SD SUBMISSION PSD 08/26/11 PRELIMINARY SD MARK DATE DESCRIPTION CONSTRUCTION DOCUMENTS ISSUE DATE: 06/29/ 12 co.�y pNON.c ,0. P 3 , $O6315S) �pROF: , $►oNP�,/ AT PROJECT NO: 11103-2047 OWNER PROJECT NO: 754 DRAWN BY: PKB CHECKED BY: JLB PROJECT MANAGER: GHS SHEET ITR TITLE: PLANS KEYNOTES -6A PARTIAL AND ci) I 11111111111•11. I 1 1 1 1{ I I l I I MIN= HI I I I RH III THIRD FLOOR (ROOM 325) ARCHITECTURAL -EXISTING / DEMO Scale: 1/4" = 1'-0" 0 2' 4' 8' THIRD FLOOR ITR -3A (ROOM 325A) ARCHITECTURAL - NEW WORK Scale: 1/4" = 1'-0" 0 2' 4' 8' ARCHITECTURAL — GENERAL \JOTES & CONSTRUCTION KEYED NOTES: A. NEW PARTITIONS ON THIS PLAN ARE NOT FIRE RATED. EXISTING ENCLOSURE OF STAIR, VENTILATION SHAFT, AND ELECTRICAL CHASE ARE 2 HOUR FIRE RATED. B. CLEAN ROOM TO PROVIDE DUST FREE ROOM UPON COMPLETION OF DEMOLITION AND PATCHING WORK. C. REFER TO DRAWING A4 FOR DETAILS AND SCHEDULES. Al PROVIDE PARTITION. 3-5/8" 18 GUAGE METAL STUDS, 16" ON CENTER. 5/8" TYPE GYPSUM WALL BOARD ON EACH SIDE. PROVIDE 3" ACOUSTIC BATT INSULATION BETWEEN STUDS. PARTITION TO EXTEND TO AND BE SEALED TO UNDERSIDE OF STRUCTURE ABOVE, APPROXIMATELY 8'-4". FIT GYPSUM WALL BOARD AROUND EXISTING PIPES AND CONDUIT. SEAL PENETRATIONS. 0 PROVIDE 3'—O" x 7'—O" x 1-3/4" FLUSH HOLLOW METAL DOOR AND FRAME, NON RATED. PAINT DOOR AND FRAME. PROVIDE HARDWARE AS FOLLOWS: 3 HINGES, STANLEY FBB 179 4-1 /2 x 4-1/2 1 DOOR CLOSER, SARGENT SERIES 35 1 LOCKSET, SARGENT HARMONY SERIES SARGENT LOCKSET, 8200 SERIES H1, ACCOMMODATE 7 PIN INTERCHANGEABLE BEST CORE. MORTISE LOCK ALL LOCKS TO BE STOREROOM LOCKS (04) FAIL SECURE STRIKES: PROVIDE WROUGHT BOXES AND STRIKES WITH PROPER LIP LENGTH TO PROTECT TRIM BUT NOT TO PROTECT MORE THAN 1/8" BEYOND TRIM, FRAME OR INACTIVE LEAF. WHERE REQUIRED, PROVIDE OPEN BACK STRIKE AND PROTECTED TO ALLOW PRACTICAL AND SECURE OPERATION. HARMONY LOCKSETS TO BE INSTALLED BY A CERTIFIED INSTALLER. 1 KEEDEX PART NO. K—DL38A24 DOOR TO FRAME POWER TRANSFER FLEX CONDUIT. 1 McKINNEY ELECTROLYNX RETROFIT CABLE FOR THE DOOR FRAME. SIZE 15'-2". 2 KICKPLATES, 8" x DOOR WIDTH -2", ROCKWOOD 3 RUBBER SILENCERS, GLYNN JOHNSON #64 1 DOOR SWEEP, PEMKO #293100CNB, CLEAR ANODIZED ALUMINUM WITH GRAY NYLON BRUSH INSERT. ALL HARDWARE TO MATCH US10 SATIN BRONZE FINISH. SEE DRAWING A4 FOR DETAIL OD DOOR FRAME IN STUD WALL. PAINT WALLS WITHIN ROOM AND NON—ROOM SIDE OF NEW PARTITION. PAINT TYPE AND COLOR TO BE SELECTED BY FACILITIES DEPARTMENT TO MATCH EXISTING PAINT TYPES AND COLOR SCHEMES. PAINT UNDERSIDE OF EXPOSED CONCRETE SLAB ABOVE. PAINT TYPE AND COLOR TO BE SELECTED BY FACILITIES DEPARTMENT TO MATCH EXISTING PAINT TYPES AND COLOR SCHEMES. PROVIDE 3/4" AC PLYWOOD ON WALLS INDICATED ON THIS PLAN. PRIME AND PAINT WITH FIRE RETARDANT, LIGHT GRAY PAINT ON ALL SURFACES AND EDGES. PLYWOOD TO BE 8 FEET HIGH AND MOUNTED 6 INCHES ABOVE FLOOR. SECURE TO WALL WITH COUNTERSINK FASTENERS 24 INCHES ON CENTER MAXIMUM, EACH WAY. ANCHOR TO STUDS WITH SCREWS. ANCHOR TO CONCRETE OR MASONRY WITH EXPANSION ANCHORS. REMOVE EXISTING LIBRARY SHELVING WITH CARE AND TURN OVER TO OWNER. PROVIDE ROOM SIGNAGE TO MATCH EXISTING BUILDING SIGNAGE. SIGN TEXT AS DIRECTED. NOTE: REFER TO DRAWING A4 FOR DETAILS AND SCHEDULES AS APPLICABLE. 300UA EX. SPRINKLER LINES (ETR) 325 REMOVE EX. SPRINKLERS/PIPE BACK TO BRANCHLINE. RELOCATE EX. SPRINKLER AWAY FROM NEW WALL. REMOVE EX. SPRINKLER AND CAP OR PLUG OUTLET IN BRANCH LINE. 4 j THIRD FLOOR (ROOM 325) MECHANICAL -EXISTING / REMOVALS Scale: 1/4" = 1'-O" 0 2' 4' 8' 300UA 325 EX. VESDA SMOKE ALARM SYSTEM PIPING (ETR) —T— _T_ —T— NM =if MEI MIK THIRD FLOOR (ROOM 325) ELECTRICAL -EXISTING / REMOVALS Scale: 1/4" = 1'-0" 0 2' 4' 8' 300UA (ETR) EX. SPRINKLER LINES (ETR) {3251 (ETR) • (ETR) PROVIDE MOUNTING SPACER TO ALLOW FOR INSTALLATION OF CHWS&R PIPING 3/4" CONDENSATE DN IN WALL 3/4" CHWS&R DN TO 2ND FL. I I 3/4" CHWS&R TO FC -3 IN RM. 625A. REFER TO DWG M2 FOR CONTINUATION (ETR) C 3/4" CHWS&R TO FC -2 325A1 FC -2 l CAP OR PLUG OUTLET IN BRANCH LINE. (ETR) THIRD FLOOR ITR -3A (ROOM 325A) MECHANICAL - NEW WORK Scale: 1/4" = 1'-0" 0 2' EX. PANEL 3B 4' 8' RELOCATE FX. SPRINKLER AWAY FROM NEW WALL. EX. VESDA SMOKE ALARM SYSTEM PIPING (ETR) 6 PROVIDE PANEL CP TR 3A THIRD FLOOR ITR -3A (ROOM 325A) ELECTRICAL - NEW WORK Scale: 1/4" = 1'-0" 0 2' 4' 8' HVAC 8c SPRINKLER SYSTEM CONSTRUCTION KEYED NOTES: 0 PROVIDE HIGH SIDEWALL CHILLED WATER FAN COIL UNIT. REFER TO DRAWING M2. REFER TO DRAWING M4 FOR UNIT SCHEDULE. 0 PROVIDE CONNECTION TO EXISTING BRANCH LINE. PROVIDE ADDITIONAL SPRINKLER COVERAGE. 0 PROVIDE DRY WALL SPRINKLER COVERAGE FOR ITR -3A ROOM. COORDINATE SPRINKLER LOCATION WITH LIGHTS, PANELS, CABLE TRAYS AND TELECOMUNICATION EQUIPMENT LOCATIONS. NOTE: REFER TO DRAWING M4 FOR DETAILS AND SCHEDULES AS APPLICABLE. ELECTRICAL CONSTRUCTION KEYED NOTES: Et E2 E3 E4 ES E6 E7 E8 E9 REMOVE PROVIDE PROVIDE PROVIDE #1. PROVIDE PROVIDE PROVIDE PROVIDE EX. LIGHT FIXTURE AND WIRING. PROVIDE END TERMINATION UNIT FOR LIGHTING TRACK. TGB PER DETAIL ON DRAWING E4. NEW DUPLEX RECEPTACLE AT 24" AFF. 20A DUPLEX RECEPTACLE AT 24" AFF. FEED FROM EX. ELECRICAL PANEL IN ADJACENT ROOM, SPARE CIRCUIT TWO 20A DUPLEX RECEPTACLES IN COMMON BOX, EACH FED FROM SEPARATE CIRCUIT. MOUNT AT 24" AFF. NEW LIGHT SWITCH, CONNECT TO EX. LIGHTING BRANCH CIRCUIT IN ROOM. NEW LIGHT FIXTURE PER SCHEDULE ON DRAWING E4. EM FIXTURE, CONNECT TO UNSWITCHED LEG OF LIGHTING BRANCH CIRCUIT THAT FEEDS THE ROOM. EXTEND EXISTING FIRE ALARM CIRCUIT TO NEW SMOKE DETECTOR. PROVIDE ALL SHUT DOWNS, TIE—INS AND VERIFICATIONS OF EXISTING ADDRESSABLE SYSTEM TO ENSURE THAT THE FACP CAN SUPPORT NEW DEVICES. CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR TESTING, REPROGRAMMING AND MODIFICATION TO EXISTING FIRE ALARM PANEL AND REMOTE ANNUNCIATORS TO SHOW NEW DEVICE(S). RELOCATE EX. LIGHT SWITCH ON BOOK STACK. PROVIDE CIRCUIT FOR ACCESS CONTROL SYSTEM READER INTERFACE MODULE AND ASSOCIATED DOOR LOCK. DURING CONSTRUCTION, WHILE PARTICULATE IS BEING GENERATED, THE SAMPLING PORTS OF THE VESDA SYSTEM SHALL BE TEMPORARILY COVERED. RECTIFICATION OF TROUBLE SIGNALS GENERATED BY THE VESDA SYSTEM SHALL BE THE CONTRACTORS RESPONSIBILITY. NOTE: REFER TO DRAWING E4 FOR DETAILS AND SCHEDULES AS APPLICABLE. GENERAL NOTES: A. REFER TO DRAWING AMEP—GEN. B. REFER TO DRAWING M2 FOR CONTINUATION AND ADDITIONAL COORDINATION REQUIREMENTS. C. REFER TO DRAWING T3 -3A FOR ADDITIONAL COORDINATION REQUIREMENTS. KEY PLAN J:\PROJECTS-Ithaca\2011\11103 CORNELL - NCP\Olin Library 20471CAD111103-2047--T3-3B.dwg SCALES ON THIS DRAWING ACCURATE WHEN PLOTTED TO: ARCH El (30X42 IN.) MAII NV 115 METRO PHONE: M ARCHI TECHNOLOGY, LLC www.archi-technology.com PARK ROCHESTER, NY 14623 585.424.1952 Fax: 585.424.4239 BEARDSLEY DESIGN ASSOCIATFS Architecture, Engineering, Landscape Architecture, P.C. Ph 315.472.5988 5789 Widewaters Parkway Fax 315.472.3523 Dewitt, New York 13214 E-mail IIDA@Beareisley.cem CORNELL UNIVERSITY OLIN LIBRARY - 2047 ITHACA, NY CLIENT: Corner University PROJECT ® NETWORK r¢_ CONNECTIVITY CD 06/29/12. CONSTRUCTION DOCUMENTS 100 DD 05/17/12 100% DD SUBMISSION 50 DD 50% DD SUBMISSION 20 SD 10/07/11 20% SD SUBMISSION PSD 08/26/11 PRELIMINARY SD MARK DATE DESCRIPTION CONSTRUCTION DOCUMENTS ISSUE DATE: 06/29/ 1 2 .OF NFw Y .c,�oNO N. Co, �,p1- ct- • of .-, <,, ,♦ , ,;, — cv , O 063153 �� AR4Fc S'rONP� AT PROJECT NO: 11103-2047 OWNER PROJECT NO: 754 DRAWN BY: PKB CHECKED BY: JLB PROJECT MANAGER: GHS SHEET TITLE: ITR -3A PARTIAL PLANS AND KEYNOTES I- 0 J 0 N 0 N a7 PLOT DATE: June EXPANSION ANCHOR CAST IN PLACE 6"W x 8" HEADER W/(2)#4 BARS. BEAR 8" EA. END 5-5/8" d • HEAD 441° 411) REMOVE EXISTING CMU FOR NEW LINTEL 7-5/8" 32" x 32" 1-1/2 HR FIRE RATED ACCESS DOOR SAWCUT OPENING. SEE DETAILS CAST IN PLACE LINTEL MILCOR UNIVERSAL FIRE RATED ACCESS DOOR DOOR SIZE: 32" x 32" FRAMED OPENING: 32.5" x 32.5" PRODUCT NUMBER: 3218-032 (1) PADDLE LATCH (4) MASONRY ANCHORS 4'-8" AFF FIRE RATED ACCESS DOOR DETAIL Scale: NONE 1 BOO A J ENLARGED PLAN -BASEMENT ROOM BOOTA Scale: 1/2" = 1'-0" 0 1' 2' 4' SEALANT, BOTH SIDES. 3/4" AC GRADE PLYWOOD PAINTED WITH FIRE RETARDANT PAINT, PER SPEC. EXISTING FLOOR/ROOF ASSEMBLY TO REMAIN (SHOWN SHADED). FINISH AS SCHED. SECURE PARTITION TO STRUCTURE AND/OR UNDERSIDE OF FLOOR ASSEMBLY ABOVE. PROVIDE FOR STRUCTURAL DEFLECTION AT CONNECTION PER SPECIFIED MANUFACTURER'S RECOMMENDATION(S). CEILING(S) TO BE REMOVED, WHERE APPLICABLE; AS SCHED. HEIGHTS MAY VARY. 18 GAUGE METAL STUD BRACING OR STRAPPING HORIZONTAL, BEHIND PLYWOOD. LIGHT GAUGE METAL FRAMING, NON—LOADBEARING. SEE SPECS. 5/" TYPE "X" GYPSUM WALL BOARD EACH SIDE, ON 3518„ 18 GUAGE METAL STUDS ON 16" CENTER. WALL BASE, AS SCHED. SEALANT, BOTH SIDES. ,� EXISTING FLOOR ASSEMBLY TO REMAIN (SHOWN SHADED) jjjj��j/ FULL -HEIGHT PARTITION ASSEMBLY SECTION DETAILS PARTITION TYPES HEAD TYPES NOTE: MATCH FRAME WIDTH (N2") TO EXISTING ADJACENT CONDITIONS. CONTRACTOR TO VERIFY. Scale: NONE GYPSUM WALLBOARD ASSEMBLY PARTITION, AS SCHEDULED. WIDTH MAY VARY. METAL STUD TRACK FRAMING © HEAD. WIDTH AS SCHEDULED. SEALANT, BOTH SIDES. STEEL DOOR FRAME, AS SCHEDULED. THROAT DEPTH MAY VARY. DOOR AND HARDWARE, AS SCHEDULED. JAMB TYPES 2,_O" DOUBLE—STUD METAL FRAMING 0 JAMB(s), BOTH SIDES. WIDTH AS SCHEDULED. STEEL DOOR FRAME, AS SCHEDULED. THROAT DEPTH MAY VARY. SEALANT, BOTH SIDES. NOTE: MATCH FRAME WIDTH (-2") TO EXISTING ADJACENT CONDITIONS. CONTRACTOR TO VERIFY. DOOR AND HARDWARE, AS SCHEDULED. GYPSUM WALLBOARD ASSEMBLY PARTITION, AS SCHEDULED. WIDTH MAY VARY. JAMB AND HEAD TYPES Scale: NONE 2'-8" ARCHITECTLRAL - CONSTRUCTION KEYED NOTES: Al PROVIDE 3-5/8" METAL STUDS, 5/8" WATER RESISTANT GYPSUM WALL BOARD, PAINT WITH TWO COATS OF TNEMEC SERIES 270 POLYAMINE EPDXY OR APPROVED EQUAL. PROVIDE CERAMIC TILE BASE TO MATCH EXISTING HEIGHT. COLOR AS SELECTED FROM MANUFACTURER'S FULL RANGE. CHASE DETAIL Scale: NONE GENERAL NOTES . REFER TO DRAWING AMEP—GEN J:\PROJECTS—Ithaca\2011\ 11103 CORNELL — NCP\Olin Library 2047\CAD\ 11103-2047--AMEP.dwci SCALES ON THIS DRAWING ACCURATE WHEN PLOTTED TO: ARCH El (30X42 IN.) Fre MO 4161.411 115 METRO PHONE: a. a www.archi-technology.com PARK ROCHESTER, NY 14623 585.424.1952 Fax: 585.424.4239 0 1 N d' 0 N >i- Gt Q >i- i: z 1 I o0 J U zQ Z 0 U � CLIENT: 1 • • UEllu a�Cornell � • f ...3 )., University CONNECTIVITY PROJECT 4'-8" AFF FIRE RATED ACCESS DOOR DETAIL Scale: NONE 1 BOO A J ENLARGED PLAN -BASEMENT ROOM BOOTA Scale: 1/2" = 1'-0" 0 1' 2' 4' SEALANT, BOTH SIDES. 3/4" AC GRADE PLYWOOD PAINTED WITH FIRE RETARDANT PAINT, PER SPEC. EXISTING FLOOR/ROOF ASSEMBLY TO REMAIN (SHOWN SHADED). FINISH AS SCHED. SECURE PARTITION TO STRUCTURE AND/OR UNDERSIDE OF FLOOR ASSEMBLY ABOVE. PROVIDE FOR STRUCTURAL DEFLECTION AT CONNECTION PER SPECIFIED MANUFACTURER'S RECOMMENDATION(S). CEILING(S) TO BE REMOVED, WHERE APPLICABLE; AS SCHED. HEIGHTS MAY VARY. 18 GAUGE METAL STUD BRACING OR STRAPPING HORIZONTAL, BEHIND PLYWOOD. LIGHT GAUGE METAL FRAMING, NON—LOADBEARING. SEE SPECS. 5/" TYPE "X" GYPSUM WALL BOARD EACH SIDE, ON 3518„ 18 GUAGE METAL STUDS ON 16" CENTER. WALL BASE, AS SCHED. SEALANT, BOTH SIDES. ,� EXISTING FLOOR ASSEMBLY TO REMAIN (SHOWN SHADED) jjjj��j/ FULL -HEIGHT PARTITION ASSEMBLY SECTION DETAILS PARTITION TYPES HEAD TYPES NOTE: MATCH FRAME WIDTH (N2") TO EXISTING ADJACENT CONDITIONS. CONTRACTOR TO VERIFY. Scale: NONE GYPSUM WALLBOARD ASSEMBLY PARTITION, AS SCHEDULED. WIDTH MAY VARY. METAL STUD TRACK FRAMING © HEAD. WIDTH AS SCHEDULED. SEALANT, BOTH SIDES. STEEL DOOR FRAME, AS SCHEDULED. THROAT DEPTH MAY VARY. DOOR AND HARDWARE, AS SCHEDULED. JAMB TYPES 2,_O" DOUBLE—STUD METAL FRAMING 0 JAMB(s), BOTH SIDES. WIDTH AS SCHEDULED. STEEL DOOR FRAME, AS SCHEDULED. THROAT DEPTH MAY VARY. SEALANT, BOTH SIDES. NOTE: MATCH FRAME WIDTH (-2") TO EXISTING ADJACENT CONDITIONS. CONTRACTOR TO VERIFY. DOOR AND HARDWARE, AS SCHEDULED. GYPSUM WALLBOARD ASSEMBLY PARTITION, AS SCHEDULED. WIDTH MAY VARY. JAMB AND HEAD TYPES Scale: NONE 2'-8" ARCHITECTLRAL - CONSTRUCTION KEYED NOTES: Al PROVIDE 3-5/8" METAL STUDS, 5/8" WATER RESISTANT GYPSUM WALL BOARD, PAINT WITH TWO COATS OF TNEMEC SERIES 270 POLYAMINE EPDXY OR APPROVED EQUAL. PROVIDE CERAMIC TILE BASE TO MATCH EXISTING HEIGHT. COLOR AS SELECTED FROM MANUFACTURER'S FULL RANGE. CHASE DETAIL Scale: NONE GENERAL NOTES . REFER TO DRAWING AMEP—GEN J:\PROJECTS—Ithaca\2011\ 11103 CORNELL — NCP\Olin Library 2047\CAD\ 11103-2047--AMEP.dwci SCALES ON THIS DRAWING ACCURATE WHEN PLOTTED TO: ARCH El (30X42 IN.) Fre MO 4161.411 115 METRO PHONE: ARCHI-TECHNOLOGY, LLC www.archi-technology.com PARK ROCHESTER, NY 14623 585.424.1952 Fax: 585.424.4239 BEARDSLW DESIGN ASSOCIATES Architecture, Engineering, Landscape Architecture, P.C. Ph 315.472.6980 5789 Widewaters Parkway Fax 315.472.3523 Dewitt, New York 13214 E-mail BDA@Reardsley.cam N d' 0 N >i- Gt Q >i- i: z Cr) CC Lil Z D J LUQ o0 J U zQ Z 0 U 0 CLIENT: 0 UEllu a�Cornell NETWORK )., University CONNECTIVITY PROJECT CD 06/29/12 CONSTRUCTION DOCUMENTS 100 DD 05/17/12 100% DD SUBMISSION 50 DD 50% DD SUBMISSION 20 SD 20% SD SUBMISSION PSD 08/05/11 PRELIMINARY SD MARK DATE DESCRIPTION CONSTRUCTION DOCUMENTS ISSUE DATE: 06/29/12 co, t,1►� � .,OF NE(y .. ow) N.0O3O ,� 4``�tYel 41 4.0 063153g�pRoF; � sloNP AT PROJECT NO: 11103-2047 OWNER PROJECT NO: 754 DRAWN BY: PKB CHECKED BY: JLB PROJECT MANAGER: GHS SHEET TITLE: ARCHITECTURAL DETAILS