Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Kroch Library
EXISTING 1-5/8" U—TRACK MTL. CHANNELS (BEYOND) #12 GA. WIRE TIES SUSPENDED FROM STRUCT. ABOVE (ALL FOUR CORNERS) 1/2" MTL. FRAMING CHANNELS. SPAN BETWEEN EXISTING SUPPORTS (4—SIDES) 5/8" TYPE "X" GWB CONTINUOUS AROUND PERIMETER THREADED FASTENERS TO MTL. FRAMING EXISTING (RATED) CEILING ASSEMBLY. CEILING TILE ADHERED TO 1/2" GYPSUM BOARD NAILED TO 7/8" ALUM. V—GROOVE CHANNELS J:\PROJECTS—Ithaca\2011\11103 CORNELL — NCP\Kroch Library 2047A\CAD\11103-2047A--AMEP.dwa SCALES ON THIS DRAWING ACCURATE WHEN PLOTTED TO: ARCH El (30X42 IN.) REMOVE AND REPLACE CEILING TILES AS REQUIRED FOR ACCESS PANEL INSTALLATION/RESTORATION J- , --ACCESS PANEL 2'—O" x 2-0" DOOR TYPICAL NOTE: SEE T2—xx.CA_CP DRAWINGS FOR ADDITIONAL LOCATIONS. PROVIDE ALL COSTS IN BASE BID. NEW ACCESS PANEL - EXISTING GWB CEILING Scale: NONE GENERAL NOTES 1. REFER TO DRAWING T1—AMEP. I M I0 � 115 METRO PHONE: ARCHITECHNOLOGY, LLC www.archi-technology.com PARK ROCHESTER, NY 14623 585.424.1952 Fax: 585.424.4239 1MBEARDSLEY DESIGN ASSOCIATES Architecture, Engineering, Landscape Architecture, P.C. Ph 315.472.6980 5789 Widewaters Parkway Fu 315.472_3523 Dewitt, New York 13214 E-mail RDAIBeardsley.cum r IIS Q N 0 N >- c (!) W II D J J W Z CC O U Q CO Z J = Q U U OQ = CLIENT: Cornell University PROJECT nil'y"G CONNECTIVITY 0 NETWORK : � 0 X: }' CD 06/ 29/12 CONSTRUCTION DOCUMENTS 100 DD 05/11/12 100% DD SUBMISSION 50 DD 50% DD SUBMISSION 20 SD 20% SD SUBMISSION PSD 08/10/11 PRELIMINARY SD SUBMISSION MARK DATE DESCRIPTION CONSTRUCTION DOCUMENTS ISSUE DATE: 06/29/12 �EOF NEW y .c IAD N, co 0 X6315,x SY �pIiiiRoF;.gio1`�'� AT PROJECT NO: 11103-2047A OWNER PROJECT NO: 754 DRAWN BY: LP/EL/PKB CHECKED BY: JLB PROJECT MANAGER: GHS SHEET TITLE: ARCHITECTURAL DETAILS A4 4 i i 9 1 II PI OT RY. nhnrrie UP UP 100SP BOOST / 1000S D //////////////////////////// 100UM ///////////////// EX. PANEL PMR 1000 R / \I 100CN DN UP M 160 FC -1 100SK I II i i L 1 DOUJ 111111111111111111 100UK 00JD 0 i 100TF 1000K OPEN TO BELOW I --- 100CT OOCN 100UT 190 0 i • 100UN UP 1005R TO UPPER MECHANICAL ROOM 1000P s i • • 1 I I i 100TE Mai 100CL 182 181 90A 100E8 100UL 180 179 UP 100SN 190B 100SH 1000P] DN UP 111111-011 IMMO IRWIN / 178 177 OPEN TO BELOW OPEN TO BELOW 170 100CG 100CH FIRST FLOOR ELECTRICAL - NEW WORK Scale: 3/32" = 1'-0" 0 4' 8' 16' 100EA D 100SG 171 172 100CJ 173 174 i i I 100EC 176 N J 176A I 75A 175 FIRST FLOOR BASEMENT 00 100SR DN 1 MOOUM a1 P-7 D 1M9OA I I I 100SN DN FIRST MEZZANINE FLOOR ELECTRICAL - NEW WORK Scale: 3/32" = 1'-0" 0 4' 8' 16' ELECTRICAL CONSTRUCTION KEYED NOTES: .—PMR, SPARE -1 GENERAL NOTES 1. REFER TO DRAWING T1—AMEP. FIRST FLOOR MEZZANINE KEY PLAN E1 PROVIDE WIRING TO PUMP P-7, (2)#10 AWG WITH (1) #10AWG GROUND, IN 3/4" CONDUIT. E2 PROVIDE STARTER WITH DISCONNECT SWITCH AND ON—OFF AUTO CONTROL SWITCH. PROVIDE (2)#10 AWG WITH (1)#10 AWG GROUND, 3/4"C TO PUMP P-7 AND TO PANEL PMR, SPARE -1. PUMP P-7 SHALL RUN WHEN EITHER FC -1 OR FC -2 IS OPERATING AND STARTER IS IN "AUTO" MODE. E3 PROVIDE (2) #10 AWG WITH (1) #1OAWG GROUND FROM FC -1 AND FC -2 AUX. RELAY TO P-7 STARTER. EX GROUND BUS — #4 AWG (ETR) ® ROOM 100UN NEW GROUND BAR #6 ITR -1A RM. 100UK #4 AWG (ETR) NEW GROUND BAR #6 GB MTR—BA - S. RM. BOOUK SUB -BASEMENT 4 AWG (ETR) TC,R GROUND BAR (ETR) RM. 28000K FIRST FLOOR BASEMENT SUB -BASEMENT FIXTURE LAMPS REMARKS TYPE DESCRIPTION VOLTS MANUFACTURER & CATALOG NUMBER QTY. WATTS LAMP CODE FA 4 FT. SURFACE FLUORESCENT WITH HIGH IMPACT ACRYLIC LENS AND ELECTRONIC BALLAST 120/277 LITHONIA CLM-232-MVOLT-GEB 2 32 F032T8/835 1,2,3 FB 2 FT. SURFACE FLUORESCENT WITH HIGH IMPACT ACRYLIC LENS AND ELECTRONIC BALLAST 120/277 LITHONIA LB-217-MVOLT-GEB101 S 2 17 F017T8/835 1,2 EM TWIN HEAD EMERGENCY LIGHTING UNIT 120/277 CFX6McPHILBEN 2 5 HALOGEN CD NOTES: 1. FURNISH WITH <10% THD ELECTRONIC BALLAST. 2. FURNISH WITH HIGH IMPACT PRISMATIC DIFFUSER. 3. PROVIDE 24" PENDANT LIGHTING FIXTURE SCHEDULE Scale: NONE r.„ GROUNDING SYSTEM RISER DIAGRAM � Scale: NONE TMGB OR TGB LABEL PROVIDE ENGRAVED TAG FOR EACH GROUNDING CONDUCTOR, BOTH ENDS AND AT EXPOSED PASS THROUGH MECHANICAL SPACES AND AT ENTRANCES/ EXITS TO SHAFTWAYS, TYPICAL. L1 DIV. 26 CONTRACTOR TO PROVIDE INSULATED TIN PLATED TELECOM SYSTEM GROUND BUS BAR. HOLE CENTERS TO MATCH LUG CONFIGURATION AND EIA/TIA 607 STANDARDS. REFER TO SECTIONS 260526 and 271100. TMGB — ERICO/ERITECH # TMGB—A20L27PT TGB — ERICO/ERITECH # TGB—A20L12PT • INSULATORS. • 5/8" LOCKWASHERS. O WALL MOUNTING BRACKET. O 5/8-11X1" H.H.C.S. BOLTS. O DIV. 26 CONTRACTOR TO PROVIDE LONG BARREL COMPRESSION LUG, TWO BOLT, COMPRESSION LUG (BURNDY HYLUG YAZ SERIES) OR EQUAL. PROVIDE A MINIMUM OF EIGHT (8) SPARE LUGS WITH 5/16" HOLES FOR FUTURE USE BY OWNER. DRILL AND TAP AS REQUIRED. SCRUFF BAR AND PROVIDE ANTIOXIDANT AS CALLED FOR. REFER TO SECTIONS 260526 and 271100. TELECOMMUNICATIONS GROUND BAR (TMGB \ TGB) DETAIL Scale: NONE 1, J:\PROJECTS—Ithaca\2011\ 11 103 CORNELL — NCP\Kroch Library 2047A\CAD\ 11103-2047A— —AMEP.dwa SCALES ON THIS DRAWING ACCURATE WHEN PLOTTED TO: ARCH El (30X42 IN.) r ' I PI�, &� 115 METRO PHONE: 1 ARCHI-TECHNOLOGY, Lv www.archi-technology.com PARK ROCHESTER, NY 14623 585.424.1952 Fax: 585.424.4239 tLABEARADSLEY DESIGN Architecture, Engineering, Landscape Architecture, P.C. Ph 315.472.6980 5789 Widewaters Parkway Fax 315.475.3523 Dewitt, New York 13214 E-mail BDAVBeardsley.enm r N .1- O N C rr—+ ^^ vl lc I -I _� ` = Q U U O Q C = ~ .__I W Z ce O U CLIENT: Ailu�jlu a Cornell University PROJECT NETWORK log CONNECTIVITY CD 06/29/12 CONSTRUCTION DOCUMENTS 100 DD 05/11/12 100% DD SUBMISSION 50 DD 50% DD SUBMISSION 20 SD 20% SD SUBMISSION PSD 08/10/11 PRELIMINARY SD SUBMISSION MARK DATE DESCRIPTION CONSTRUCTION DOCUMENTS ISSUE DATE: 06/29/12 F �pRQF OF NEiry 40N0N.cVO%r 063153 �� , s'9NP��; AT PROJECT NO: 11103-2047A OWNER PROJECT NO: 754 DRAWN BY: LP/EL/PKB CHECKED BY: JLB PROJECT MANAGER: GHS SHEET TITLE: ELECTRICAL DETAILS t E4 PLOT BY: pba 0,4 0) PLOT DATE: June r i t (4) 4"C UP AND DOWN I i (ETR BOOUK (ETR) (ETR) s r BOOJD CO BASEMENT MDF (ROOM BOOUK) ARCHITECTURAL - EXISTING / DEMO Scale: 1/2" = 1'-0" 0 1' 2' 4' Cr (4) 4"C UP AND DOWN (ETR BOOUK (ETR) (ETR) /le i BASEMENT MTR-BA (ROOM BOOUK) ARCHITECTURAL - NEW WORK Scale: 1/2" = 1'-0" 0 2' 4' ARCI- ITECTURAL - CONSTRUCTION <EYED NOTES: PROVIDE DOOR SWEEPS. FOR 1 INCH GAP OR LESS SWEEP SHALL BE PEMKO #293100CNB — CLEAR ANODIZED ALUMINUM W/GRAY NYLON BRUSH INSERT. FOR 1 INCH TO 1-3/8" GAP, PROVIDE PEMKO #18137CNB (SAME FINISH). 0 PROVIDE FIRESTOPPING AROUND (4) EXISTING 4" CONDUITS THROUGH FLOOR. NOTE: REFER TO DRAWING A4 FOR DETAILS AND SCHEDULES AS APPLICABLE. "NOVA MINA 111.0101 REMOVE GRILLE AND CAP EX. DUCT SPRINKLER (ETR) BOOJD SPRINKLER (ETR) C LEAN OUT BOOJ 3/4" CHWS&R HVAC CONSTRUCTION KEYED NOTES: 0 PROVIDE HIGH SIDEWALL CHILLED WATER FAN COIL UNIT. MOUNT BOTTOM OF UNIT APPROXIMATELY 9'-2" AFF. REFER TO DRAWING M4 FOR FOR UNIT SCHEDULE. BASEMENT MDF (ROOM BOOUK) MECHANICAL - EXISTING / REMOVALS Scale: 1/2" = 1'-0" PANEL PB1 (ETR) 0 1' 2' 4 (ETR) BOOUK PB1,13 (ETR) PB1,15 BOOJD (ERL) EP EP R,19 (ETR) R,21 BASEMENT MDF (ROOM BOOUK) ELECTRICAL - EXISTING / REMOVALS Scale: 1/2" = 1'-0" 0 1' 2' 4' 3/4" CONDENSATE DN TO MOP SINK. TERMINATE 4" ABOVE MOP SINK. BASEM JT MTR-BA (ROOM BOOUK) MECHANICAL - NEW WORK Scale: 1/2" = 1'-0" 0 1' 2' 4' PB1, SPARE -2 BOOJD PANEL PB1 (ETR) BASEMENT MTR-BA (ROOM BOOUK) ELECTRICAL - NEW WORK Scale: 1/2" = 1'-0" 0 1' 2' 4' EPMR,19 (ETR) EPMR,21 PB1,13 (ETR) PB1,15 NOTE: REFER TO DRAWING M4 FOR DETAILS AND SCHEDULES AS APPLICABLE. ELECTRICAL CONSTRUCTION <EYED NOTES: E1 REMOVE EX. GROUND BAR AND TURN OVER TO OWNER. E2 PROVIDE NEW TMGB AND ASSOCIATED GROUNDING PER DETAILS ON DRAWING E4. E3 PROVIDE EM LIGHT, CONNECT TO UNSWITCHED LEG OF EXISTING LIGHTING CIRCUIT. E4 PROVIDE CONVENIENCE OUTLETS AS INDICATED, AT 24" AFF. PROVIDE (1) 20A 1P BREAKER WITH (3) #12, 3/4"C. E5 RELOCATE EX. QUAD RECEPTACLES. EXTEND EX. BRANCH CIRCUIT WIRING AS REQUIRED. NOTE: REFER TO DRAWING E4 FOR DETAILS AND SCHEDULES AS APPLICABLE. J:\PROJECTS-Ithaca12011\11103 CORNELL - NCP\Kroch Library 2047A\CAD\11103-2047A--T3-B.dwg SCALES ON THIS DRAWING ACCURATE WHEN PLOTTED TO: ARCH El (30X42 IN.) GENERAL NOTES: A. REFER TO DRAWING AMEP—GEN FOR GENERAL NOTES. . REFER TO DRAWINGS AMEP-1A, M2 FOR CONTINUATION AND ADDITIONAL COORDINATION REQUIREMENTS. . REFER TO DRAWING T3—BA FOR ADDITIONAL COORDINATION REQUIREMENTS. MTR—BA (RM. BOOUK) KEY PLAN i Fr Mbe gmiumr 115 METRO PHONE: LL ARCHI-TECHNOLOGY, C www.archi-technology. corn PARK ROCHESTER, NY 14623 585.424.1952 Fax: 585.424.4239 • a A BASLE' DESIGN III ASSOCIATES Architecture, Engineering, Landscape Architecture, P.C. Ph 315.472_15980 5789 Widewaters Parkway Fax 315.472.3523 Dewitt, New York 13214 E-mail BBAMBeardsle7.cem Q N c) N 1 >-- f:: c ll� (l) W > IH Z D J W Z Ce O U m z = Q U U O Q oC II CLIENT: %.1, M Cornell University CONNECTIVITY PROJECT NETWORK CD /29/12 CONSTRUCTION DCCUMEN T S 100 DD 05/11/12 100% DD SUBMISSION 50 DD 50% DD SUBMISSION 20 SD 09/30/11 20% SD SUBMISSION PSD 09/07/11 PRELIMINARY SD SUBMISSION MARK DATE DESCRIPTION CONSTRUCTION DOCUMENTS ISSUE DATE: 06/29/ 1 2 co.s FQ 'OF NEWS -,OND N. Co Z 063153 - DFo. SIONP AT PROJECT NO: 11103-2047A OWNER PROJECT NO: 754 DRAWN BY: LP/EL/PKB CHECKED BY: JLB PROJECT MANAGER: GHS SHEET TITLE: MTR-BA PARTIAL PLANS AND KEYNOTES v AMEP—BA 0 000J (4) 40 UP AND DOWN (ETR) 100U K X N. N. 1, N. N.. e (ETR) 100JD FIRST FLOOR IDF (ROOM 100UK) ARCHITECTURAL - EXISTING / DEMO Scale: 1/2" = 1,-0" 1' 2' 4' MEMMEN 100LJJ (4) 4"C UP AND DOWN (ETR) 100U 1, N. N. N. (ETR) 100, DI FIRST FLOOR ITR -1A (ROOM 100UK) ARCHITECTURAL - NEW WORK Scale: 1/2" = 1'-0" o 1' 2` 4' ARCHITECTURAL - CONSTRUCTION KEYED NOTES: 0 PROVIDE DOOR SWEEPS. FOR 1 INCH GAP OR LESS SWEEP SHALL BE PEMKO #293100CNB — CLEAR ANODIZED ALUMINUM W/GRAY NYLON BRUSH INSERT. FOR 1 INCH TO 1-3/8" GAP, PROVIDE PEMKO #18137CNB (SAME FINISH). 0 PROVIDE FIRESTOPPING AROUND (4) EXISTING 4", AND (4) EXISTING 1" CONDUITS THROUGH FLOOR. NOTE: REFER TO DRAWING A4 FOR DETAILS AND SCHEDULES AS APPLICABLE. 1000, SPRINKLER (ETR) VAV & DUCTWORK (ETR) REMOVE GRILLE AND CAP EX. DUCT 000 HWS&R — (ETR) FIRST FLOOR IDF (ROOM 100UK) MECHANICAL - EXISTING / REMOVALS Scale: 1/2" = 1`-0" 0 1' 2' 4' 1 00J D 7 -- 000J SPRINKLER (ETR) VAV & DUCTWORK (ETR) CAPPED REFER TO DWG M2 FOR CONTINUATION 3/4" CHWS&R CLEAN OUT CAPPED 3/4" CONDENSATE 100JD FIRST FLOOR ITR -1A (ROOM 100UK) MECHANICAL - NEW WORK Scale: 1/2" = 1'-0" 2' 4' 3/4" CHWS&R REFER TO DWG M2 FOR CONTINUATION 3/4" CHWS&R DN TO MTR—BA, RM BOOUK 3/4" CONDENSATE DN TO MOP SINK. TERMINATE 4" ABOVE MOP SINK. HVAC CONSTRUCTION KEYED NOTES: 0 PROVIDE HIGH SIDEWALL CHILLED WATER FAN COIL UNIT. MOUNT BOTTOM OF UNIT APPROXIMATELY 7'-4" AFF. REFER TO DRAWING M4 FOR FOR UNIT SCHEDULE. NOTE: REFER TO DRAWING M4 FOR DETAILS AND SCHEDULES AS APPLICABLE. PANEL P1 (ETR) 00Lij 000,K (ETR) FIRST FLOOR IDF (ROOM 100UK) ELECTRICAL - EXISTING / REMOVALS Scale: 1/2" = 1'-0" 0 ====== 1' 2' 4' PANEL P1 (ETR) EPMR,25 (ETR) FIRST FLOOR ITR -1A (ROOM 100UK) ELECTRICAL - NEW WORK Scale: 1/2" = 1'-0" 2' 4' EPMR,23 (ETR) ELECTRICAL CONSTRUCTION KEYED NOTES: • REMOVE EX. GROUND BAR AND TURN OVER TO OWNER. 0 PROVIDE NEW TGB AND ASSOCIATED GROUNDING PER DETAILS ON DRAWING E4. • PROVIDE EM LIGHT, CONNECT TO UNSWITCHED LEG OF EXISTING LIGHTING CIRCUIT. 0 PROVIDE CONVENIENCE OUTLETS AS INDICATED, AT 24" AFF UNLESS NOTED OTHERWISE PROVIDE (1) 20A 1P BREAKER WITH (3) #12, 3/4"C. • RELOCATE EX. QUAD RECEPTACLES. EXTEND EX. BRANCH CIRCUIT WIRING AS REQUIRED. NOTE: REFER TO DRAWING E4 FOR DETAILS AND SCHEDULES AS APPLICABLE. JAPROJECTS-Ithaca12011111103 CORNELL - NCP\Kroch Library 2047A\CAD111103-2047A--T3-1.dwg SCALES ON THIS DRAWING ACCURATE WHEN PLOTTED TO: ARCH El (30X42 IN.) GENERAL NOTES: A. REFER TO DRAWING AMEP—GEN FOR GENERAL NOTES. B. REFER TO DRAWING M2 FOR CONTINUATION AND ADDITIONAL COORDINATION REQUIREMENTS. C. REFER TO DRAWING T3 -1A FOR ADDITIONAL COORDINATION REQUIREMENTS. ITR -1A (RM. 100UK) KEY PLAN I tr impni 41bIARCHI-TECHNOLOGY, emA 115 METRO PHONE: LLC www.archi-technology.com PARK ROCHESTER, NY 14623 585.424.1952 Fax: 585.424.4239 ILABEARADSLEY DESIGN Architecture, Engineering, Landscape Architecture, P.C. Ph 315.472.6980 5789 Widewaters Parkway Fsx 315.472.3523 Dewitt, New York 13214 E-mail BDA@Reartigley_eum < N lir 0 NI I ›.- C: < ce Z ..._i 1 < U U 0 < 1 F- II (/) 111 > II z .....i LLI Z Ct 0 U CLIENT: ,,kti Pi University CONNECTIVITY PROJECT , u 0 NETWORK -)'Cornell z x9° CD '29/12 CONSTRUCT iON DOCUMENTS 100 DD 05/11/12 100% DD SUBMISSION 50 DD 50% DD SUBMISSION 20 SD 09/30/11 20% SD SUBMISSION PSD 09/07/11 PRELIMINARY SD SUBMISSION MARK DATE DESCRIPTION CONSTRUCTION DOCUMENTS ISSUE DATE: 06/29/12 ,OF NEilek ,Qt• 01,10 N. Co ° co -Ots i- 42- 4" -t- , <b,0 06315'3 SKO AT PROJECT NO: 11103-2047A OWNER PROJECT NO: 754 DRAWN BY: LP/EL/PKB CHECKED BY: JLB PROJECT MANAGER: GHS SHEET TITLE: ITR -1A PARTIAL PLANS AND KEYNOTES AM EP lA v , une 19, 2012 UP 100C\ U D DN 100_S 00_V =C 3/4" CHWS&R 10 t ! ( I I l II DN 3/4" CONDENSATE 3/4" CONDENSATE DN TO MOP SINK. TERMINATE 4" ABOVE MOP SINK 10 ■ i 1 3/4" CHWS&R 0 ■ i 11 1 t ■ t 374" CHWS&R C 1009 i/////iii//////////////////t ////////// UP 100SR 3/4" CHWS&R UP TO UPPER MECHANICAL ROOM r f 67— 3/4" CHWS&R ROUTE AS HIGH AS POSSIBLE 190 EX. MOP SINK 3/4" CHWS&R DN TO MTR—BA, RM BOOUK i t 00 82 OOCK OPEN TO BELOW ROC_ t t 1 i t a 90A 181 7 L 00 -B COU 79 6 1 DN UP II II 78 177 FIRST FLOOR MECHANICAL - NEW WORK Scale: 1/8" = 1'-0" 0 4' 8' 16' OPEN TO BELOW t t 00c, IC 176A 175A, GENERAL NOTES: A. REFER TO DRAWING AM EP—GEN FOR GENERAL NOTES. B. REFER TO AMEP—BA AND AM EP—SBA FOR FURTHER INFORMATION. HVAC CONSTRUCTION KEYED NOTES: 0 PROVIDE NEW PUMP (P-7). REFER TO DWG. M4 FOR PUMP SCHEDULE. NOTE: REFER TO DRAWING M4 FOR DETAILS AND SCHEDULES AS APPLICABLE. v 0 0 3/4" CHWS&R DN V P-6 (ETR) P-5 (ETR) CIRCUIT — SETTER P-7 ISOLATION VALVE (TYP) 3/4" CHWS&R DN TO LOWER MECHANICAL ROOM FIRST MEZZANINE FLOOR MECHANICAL - NEW WORK Scale: 1/8" = 1'-0" 0 4' 8' 16' EX. 6" CAMPUS CHWS TO REMAIN EX. 6" CAMPUS CHWR TO REMAIN ITR -1A BELOW (RM. 100UK) FIRST FLOOR MEZZANINE KEY PLAN ITR -1A (RM. 100UK) FIRST FLOOR KEY PLAN J:\PROJECTS-Ithaca12011\11103 CORNELL - NCP\Kroch Library 2047A\CAD\M2-1.dwg SCALES ON THIS DRAWING ACCURATE WHEN PLOTTED TO: ARCH El (30X42 IN.) Men F,,,ARCHI-TECHNOLOGY, 115 METRO PHONE: LLC www.archi-technology. corn PARK ROCHESTER, NY 14623 585.424.1952 Fax: 585.424.4239 uks III BEARDSLEY DESIGN iv wx ASSOCIATES Architecture, Engineering, Landscape Architecture, P.C. Ph 315.472.6980 5789 Widewaters Parkway Fax 315.472.3523 Dewitt, New York 13214 E-mail BDA@Beardsley.com r Q N 1- O N ce c /II UVJ LL LU z D -J J LU ° z J = Q U U O Q Z Ct 0 U Ce ~ CLIENT: CONNECTIVITY Cornell University PROJECT / npJ 4 I NETWORK l -D - CD 06/29/12 CONSTRUCTION DOCUMENTS 100 DD 05/11/12 100% DD SUBMISSION 50 DD 50% DD SUBMISSION 20 SD 09/30/11 20% SD SUBMISSION PSD 09/07/11 PRELIMINARY SD SUBMISSION MARK DATE DESCRIPTION CONSTRUCTION DOCUMENTS ISSUE DATE: 06/29/12 .0,-01' co <<o ,c.OF NEWY N. co j 06315'3 s1oNP \V'pRoF:, AT PROJECT NO: 11103-2047A OWNER PROJECT NO: 754 DRAWN BY: LP/EL/PKB CHECKED BY: JLB PROJECT MANAGER: GHS SHEET TITLE: BASEMENT AND FIRST FLOOR PLAN -MECHANICAL PLANS M 2 Or PLOT BY: pbarri D 0 F - PROVIDE ESCUTCHEON PLATES AT ALL PIPE PENETRATIONS EXPOSED TO VIEW. SIZE ESCUTCHEON AROUND INSULATION ON INSULATED PIPE AND AROUND PIPE ON UNISULATED PIPES PIPE Q a (/i\\\\\\\ FIRE RATED WALL SLEEVE WHERE REQUIRED BY SPECIFICATIONS /\\\\\\\l/tel PIPE INSULATION - BUTT TIGHT TO FiRESTOPPING SYSTEM PROVIDE FIRESTOPPING SYSTEM PER SPECIFICATIONS FIRE RATED WALL PENETRATION DETAIL Scale: NONE PROVIDE INSULATION SHIELD (Sc INSERT FOR ALL PIPING BAND —� —HANGER RODS HANGER ROD INSULATION CHANNEL OR SIDE VIEW ANGLE TRAPEZE HANGER /NSU LAT ION SHIELD AT HANGER ADJUSTABLE HANGER NOTE: REFER TO PROJECT SPECIFICATION FOR ROD DIAMETER, END CONDITION (CLAMP, ANCHOR, ETC.) HANGER TYPES, AND CONFIGURATION. PROVIDE HIGH COMPRESSIVE STRENGTH INSUL INSERT BETWEEN PIPE & INSULATION SHIELD C LEVIS HANGER ROD INSULATION WELD SADDLE ADJUSTABLE ROLLER HANGER PIPE HANGER Scale: NONE 15:)Scale: NONE PROVIDE ESCUTCHEON PLATES AT ALL PIPE PENETRATIONS EXPOSED TO VIEW, SIZE ESCUTCHEON AROUND INSULATION ON INSULATED PIPE AND AROUND PIPE ON UNISULATED PIPES- PIPE IPES- PIPE i•m•amdmi or"! `tMLI"`E-i NON -FIRE RATED WALL SLEEVE WHERE REQUIRED BY SPECIFICATIONS 1111,. 111116116, 111161161111EmliblEr IIIIIIIIII PIPE INSULATION - INSULATION CONTINUOUS THROUGH WALL OPENING. N PROVIDE 1" CLEARANCE ALL AROUND NON -FIRE RATED WALL PENETRATION DETAIL ISOLATION VALVE (TYPICAL) FLOW BALANCING VALVE COIL MANUAL AIR [VENT MV NOTES: STRAINER AIR FLOW PETE'S PLUGS (TYPICAL) -UNION FLANGE (TYPICAL) THERMOMETER (TYPICAL) DRAIN W/HOSE END 1. PIPING TO ALLOW REMOVAL OF COIL WITH OUT REMOVING PIPING BEYOND UNIONS OR FLANGES. 2, FOR UNITS WITH MORE THAN ONE SECTION, PROVIDE FLOW BALANCER, UNIONS/ FLANGES, FLEXIBLE CONNECTORS, DRAINS AND AIR VENTS FOR EACH COIL. CHILLED WATER COIL PIPING DETAIL Scale: NONE PUMP SCHEDULE (P) UNIT LOCATION AREAS SERVED PUMP TYPE MEDIA PUMP HEAD PUMP FLOW (GPM) FLUID TEMP (F) MOTOR DATA DESIGN BASIS NOTES: VOLT PH HP SENSIBLE MBH P_7 UPPER MECHANICAL ROOM MTR—BA &ITR -1 A BOOSTER PUMP CHILLED WATER 25 3.0 45 120 1 1/6 BELL &GOBBET PL -36 — 75 63 55 54 6.6 5.4 52 62 1.5 2.2 EMI WCP-09 1,2,3,4,5 FC -2 NOTES: 1. NOT USED NEW PUMP UNIT SCHEDULE Scale: NONE J:\PROJECTS—Ithaca\2011\11103 CORNELL — NCP\Kroch Library 2047A\CAD \11103-2047A--AMEP.dwq CONCRETE DECK EXPANSION SHIELDS CONCRETE ANCHORS WASHER (TYPICAL) EXPANSION NAILS NOTE: REFER TO SPECIFICATION FOR REQUIRED ANCHOR CONFIGURATION. CONCRETE ANCHOR DEVICE DETAIL Scale: NONE COOLING COIL DRAIN SEE PLANS FOR CONTINUATION NOTE: L =INCH (MINIMUM) H =INCH PLUS THE TOTAL UNIT STATIC PRESSURE AT WORST CASE (LOADED FILTERS) UNDER POSITIVE PRESSURE COOLING COIL -DRAIN SEE PLANS FOR CONTINUATION —� CONNECT TO EXISTING COOLING COIL CONDENSATE DRAIN NOTE: L = H + J + PIPE DIAMETER H = 1 INCH FOR EACH INCH OF NEGATIVE PRESSURE* + 1 INCH J 1 * NEGATIVE PRESSURE = TOTAL UNIT STATIC PRESSURE AT WORST CASE (LOADED FILTERS) MINUS EXTERNAL PRESSURE UNDER NEGATIVE PRESSURE CONNECT TO EXISTING COOLING COIL CONDENSATE DRAIN TYPICAL COOLING COIL DRAIN Scale: NONE STRAINER ISOLATION VALVE (TYPICAL) —RETURN CIRCU PUMP GENERAL NOTES 1. REFER TO DRAWING T1—AMEP. PRESSURE GAUGE (0#-100# PSI) 1/4" SUPPLY TRIPLE DUTY VALVE UN (TYPIIONCAL) ATING IN LINE PUMP DIAGRAM DETAIL 7) Scale: NONE UNIT LOCATION AIRFLOW ELECTRICAL CHILLED WATER COIL Architecture, Engineering, Landscape Architecture, P.C. Ph 315.472.4980 5789 Widewaters Parkway Fax 315.472.3523 Dewitt, New York 13214 E-mail BBA@Heardaley.cam MOTOR HP (WATTS) V PH FLA EDB EWB LDB LWB TOTAL MBH SENSIBLE MBH EWT LWT GPM FLUID PD MANUF/MAKE NOTES FC -1 IIF -1A 250 23 115 1 .64 75 63 55 54 6.6 5.4 52 62 1.5 2.2 EMI WCP-09 1,2,3,4,5 FC -2 MTR—BA 250 23 115 1 .64 75 63 55 54 6.6 5.4 52 62 1.5 2.2 EMI WCP-09 1,2,3,5 NOTES: 1. PROVIDE WALL MOUNTED THERMOSTAT. 2. PROVIDE FILTER 3. PROVIDE SMOOTH SQUARE BACKING BETWEEN BLOCK WALL AND UNIT TO ABSORB ANY VIBRATION. 4. PROVIDE CONDENSATE PUMP. 5. EWT = 52'F DURING WINTER MONTHS. EWT = 45' DURING SUMMER MONTHS. SCALES ON THIS DRAWING ACCURATE WHEN PLOTTED TO: ARCH El (30X42 IN.) NEW CHILLED WATER FAN COIL UNIT SCHEDULE Scale: NONE 1 rw' VIP 115 METRO PHONE: ARCHI-TECHNOLOGY, L_ www.archi-technology.com PARK ROCHESTER, NY 14623 585.424.1952 Fax: 585.424.4239 BLARASSOCIATESDSLLY DESIGN Architecture, Engineering, Landscape Architecture, P.C. Ph 315.472.4980 5789 Widewaters Parkway Fax 315.472.3523 Dewitt, New York 13214 E-mail BBA@Heardaley.cam Q N O N ce Q ce ° z =Q U U O Q oC ~ H CO Ct w z D J J w Z ce O U CLIENT: Cornell University PROJECT . 4 CONNECTIVITY NETWORK m� CD 06/29/12 CONSTRUCTION DOCUMENTS 100 DD 05/11/12 100% DD SUBMISSION 50 DD 50% DD SUBMISSION 20 SD 20% SD SUBMISSION PSD 08/10/11 PRELIMINARY SD SUBMISSION MARK DATE DESCRIPTION CONSTRUCTION DOCUMENTS ISSUE DATE: 06/29/12 co.0y�oNDN.c,,O. FSA .(OF NEW ,. -,....1_,,_.m., 06315'3 , OF=. S►ONP AT PROJECT NO: 11103-2047A OWNER PROJECT NO: 754 DRAWN BY: LP/EL/PKB CHECKED BY: JLB PROJECT MANAGER: GHS SHEET TITLE: MECHANICAL DETAILS M4 r PL❑T BY! pbarrie PL❑T DATE' June 19, 2012 80 280 280009 28000 2800TF 2800EC 290000 2800CH 290000 SUB -BASEMENT - KEY PLAN Scale: 1/32" = 1'-0" 0 16' 32' 64' 100CG 100CH 10050 FIRST FLOOR - KEY PLAN Scale: 1/32" = 1'-0" 0 16' 32' 64' BASEMENT - KEY PLAN Scale: 1/32" = 1'-0" 0 16' 32' 64' 10009 t 19000M MOO 3 77f 0 1 7 1{ f! I J l ill 11 I I i I 1 I 1 1! I I 1 1 i 1 1 I I ill t i 1 1 1 I t 1' i 1 al f 3 F 1 3 I} 1 1 j i i t t f 1 1 1 i 00E8 f1M005H No I TO J- 00 7 1975 FIRST FLOOR MEZZANINE - KEY PLAN Scale: 1/32" = 1'-0" 0 16' 32' 64' 14.„, J1\PROJECTS—Ithaca\2011\11103 CORNELL — NCP\Kroch Library 2047A\CAD \11103-2047A--T1—SZldwg SCALES ON THIS DRAWING ACCURATE WHEN PLOTTED TO: ARCH El (30X42 IN.) lak s IPARCHhTECHNOLOGY, LLC &www.archi-technology.com 115 METRO PARK ROCHESTER, NY 14623 PHONE: 585.424.1952 Fax: 585.424.4239 r 4:t- 0 N 1 >-- OC Q c ° z J I Q U U 0 Q = 10 cc W z D W z cc 0 U ~ CLIENT: ,' N3 Pt © k Cornell University PROJECT up CONNECTIVITY NETWORK CD 06/29/12 CONSTRUCTION DOCUMENTS 100 DD 05/11/12 100% DD SUBMISSION 50 DD 50% DD SUBMISSION 20 SD 20% SD SUBMISSION PSD 08/10/11 PRELIMINARY SD SUBMISSION MARK DATE DESCRIPTION CONSTRUCTION DOCUMENTS ISSUE DATE: 06/29/12 co 4 �RoF:. OF NEWY -11'pND N. co 'f' T Y•j 2� 063153 9 Sto" AT PROJECT NO: 11103-2047A OWNER PROJECT NO: 754 DRAWN BY: LP/EL/PKB CHECKED BY: JLB PROJECT MANAGER: GHS SHEET TITLE: AM EP -AREAS OF WORK Ti-AMEP R ELL NINE NETWORK CONNECTIVITY PROD CT CH LI''A'Y - 2047A PROJECT SITE PLAN N SMITH HALL 2013 ORRILL HAL 2001 MI Irsl--- r 4 re -Ar A I III 111 yj ,#40, PLATFORM OLIN LIBRARY 2047 UR1S LIBRARY 2010 PAVED PARKING PUS ST 2088 WILLARD STRAIGHT HALL 2020 BARNES HALL 2009 DRAWING INDEX DRAWING DESCRIPTION T -COVER DRAWING INDEX AND PROJECT SITE PLAN T -GEN STANDARD SYMBOLS, NOTES, ABBREVIATIONS (T -SERIES) T1 TI. -SZ TR SERVING ZONES, PLAN VIEWS AND BLDG. SECTION VIEW T1 -PL PATHWAYS LOGICAL RISER DIAGRAMS Ti -CL COPPER LOGICAL RISER DIAGRAMS T1 -FL FIBER LOGICAL RISER DIAGRAMS T2 T2-SB.CA CP SUB -BASEMENT PATHWAYS AND CABLING T2-B.CA_CP BASEMENT PATHWAYS AND CABLING T2-1.CA_CP FIRST FLOOR PATHWAYS AND CABLING T2-1M.CA_CP FIRST FLOOR MEZZANINE PATHWAYS AND CABLING T3 T3 -BA MTR-BA ENLARGED PLANS AND ELEVATIONS T3 -1A ITR -1A ENLARGED PLANS AND ELEVATIONS AMEP AMEP-GEN TI-AMEP AMEP-AREAS OF WORK AMEP-BA MTR-BA PARTIAL PLANS AND KEYNOTES AMEP-1A ITR -1A PARTIAL PLANS AND KEYNOTES A4 ARCHITECTURAL DETAILS M4 MECHANICAL DETAILS E4 ELEC. I RICAL DETAILS M2 BASEMENT AND FIRST FLOOR PLAN -MECHANICAL PLANS J:\PROJECTS-Ithaca12011111103 CORNELL - NCP\Kroch Library 2047A\CAD111103-2047A--T-COVER.dwg SCALES ON THIS DRAWING ACCURATE WHEN PLOTTED TO: ARCH El (30X42 IN.) pr ri ARCHI-TECHNOLOGY, LLC www.archi-technology.com ROCHESTER, NY 14623 Fax: 585.424.4239 115 METRO PARK PHONE: 585.424.1952 CORNELL UNIVERSITY KRocH LIBRARY .3Si 2047A ITHACA, NY II' CLIENT: Cornell University PROJECT w) ry NETWORK CONNECTIVITY CD 129/12 CONSTRUCTION DOCUMENTS 100 DD 05/1 1 /12 100% DD SUBMISSION 50 DD 04/06/12 50% DD SUBMISSION 20 SD 09/30/11 20% SD SUBMISSION PSD 09/07/11 PRELIMINARY SD SUBMISSION MARK DATE DESCRIPTION CONSTRUCTION DOCUMENTS ISSUE DATE: 06 f 29 f 1 2 , AT PROJECT NO: 11103-2047A OWNER PROJECT NO: 754 DRAWN BY: LP/EL/PKB CHECKED BY: JLB PROJECT MANAGER: GHS SHEET TITLE: DRAWING INDEX AND PROJECT SITE PLAN T -COVER 0 0 m F- 0 O_ ne 28, 2012 PLOT DATE GENERAL PROJECT NOTES A. REFER TO A-, E-, AND M -SERIES DRAWINGS FOR AMEP SYMBOLS AND ABBREVIATIONS. B. REFER TO SPECIFICATION (SPEC) SECTION: DIVISION (DIV) 01 WORK UNDER CONTRACT. C. THIS INFORMATION REPRESENTS EXISTING CONDITIONS BASED ON ORIGINAL DRAWINGS AND OBSERVED SITE CONDITIONS. THE CONTRACTOR SHALL FIELD VERIFY EXACT ROUTING, DIMENSIONS AND QUANTITIES. THE CONTRACTOR SHALL DISCONNECT, REMOVE AND RECYCLE/DISPOSE OF ALL EXISTING CABLING AND DEVICES THAT ARE NOT SCHEDULED FOR REUSE. D. RACEWAY, CONDUIT, CABLING AND ELECTRICAL/MECHANICAL PATHS ARE SHOWN FOR REFERENCE ONLY. EACH CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS AND SHALL DETERMINE BEST PATHS FOR NEW INSTALLATION THAT WILL CAUSE THE LEAST DISTURBANCE TO OCCUPIED SURROUNDINGS AND BUILDING OPERATIONS (INCLUDING EVENING CLASSES). E. EACH CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND PERFORM EXPLORATORY INVESTIGATIONS FOR CONCEALED CONDITIONS AS REQUIRED. EQUIPMENT LOCATIONS AND ROUTES ARE APPROXIMATE AND MINOR ADJUSTMENTS TO THE INSTALLATION WILL BE REQUIRED TO AVOID CONFLICTS WITH EXISTING EQUIPMENT, APPARATUS, AND OCCUPANTS' FURNITURE AND PERSONAL BELONGINGS. F. ALL DRAWINGS ARE SCHEMATIC IN NATURE. THE CONTRACTOR SHALL PROVIDE OFFSETS, ENTRANCE END FITTINGS, RADIUS FITTINGS, HANGERS, ANCHORS, SUPPORT, WIRING AND ACCESSORIES NECESSARY FOR A COMPLETE, OPERATIONAL INSTALLATION. G. IT IS THE RESPONSIBILITY OF EACH CONTRACTOR TO COORDINATE WORK SHOWN ON THEIR CONTRACT DOCUMENTS WITH THE WORK OF OTHER TRADES PRIOR TO SCHEDULING, SHUTDOWN, DEMOLITION, FABRICATION OR INSTALLATION OF ANY WORK OR EQUIPMENT. EQUIPMENT OR DEVICES THAT CANNOT CHANGE LOCATION SHALL TAKE PRECEDENCE OVER THOSE THAT CAN CHANGE LOCATION. H. ALL TRADES AND CONTRACTS ARE RESPONSIBLE TO REVIEW SITE-SPECIFIC CLASSROOM SCHEDULING (DAILY AND WEEKLY), SPECIAL EVENTS/CONFERENCES, UNIVERSITY ACADEMIC CALENDARS, UNIVERSITY CLOSING AND HOLIDAYS. FACTOR WORK SCHEDULING AND MANPOWER LOADING IN SUCH A WAY SO AS TO MINIMIZE STUDENT AND STAFF DISRUPTIONS. I. PROVIDE SCHEDULES AND ONGOING PROGRESS REPORT SUBMITTALS FOR DEMOLITION AND NEW CONSTRUCTION AS CALLED FOR. REFER TO DIV 01 - SUBMITTAL PROCEDURES, AND DIV 01 - PROJECT MEETINGS SPECIFICATION SECTIONS. J. ALL TRADES AND CONTRACTS ARE RESPONSIBLE FOR THEIR OWN DEMOLITION, TEMPORARY FACILITIES, SAFETY PROGRAMS, PATCHING, PAINTING, FIRESTOP, TRASH REMOVAL/DISPOSAL, ROUTINE CLEANING, SPECIAL TELECOMMUNICATION ROOM CLEANING AND FINAL CLEANING, AS CALLED FOR. REFER TO SPEC SECTIONS IN DIV 01 THROUGH AND INCLUDING DIV 09 AS APPLICABLE. K. WHEN DRY CUTTING PLASTER, GYPSUM, CONCRETE MASONRY UNITS OR PLYWOOD - PROVIDE APPROPRIATE DUST AND NOISE CONTROL TEMPORARY PARTITIONS AND MAINTAIN EGRESS AND FIRE ALARM SYSTEM OPERATION. PROVIDE ZIP -WALL DUST BARRIERS OR OTHER APPROPRIATE PROTECTION TO LOCALIZE CLEANUP AND MINIMIZE THE EXTENTS OF FIRE ALARM SHUTDOWNS AND PREVENT FALSE FIRE ALARMS FOR SMALL SCALE CUTTING AND DEMOLITION. WHERE GENERAL CONSTRUCTION WILL CREATE DUST AND DEBRIS, THE CONTRACTOR SHALL PROVIDE PROTECTIVE COVERING FOR FURNITURE, FURNISHINGS AND EQUIPMENT. L. "ERL" ADJACENT TO A DEVICE, FIXTURE OR PIECE OF EQUIPMENT INDICATES AN EXISTING ITEM TO BE RELOCATED. DISCONNECT AND REMOVE THE ITEM. REMOVE ALL UNNECESSARY RACEWAY AND WIRING. REINSTALL AND RECONNECT ITEM AS REQUIRED. M. "ETR" ADJACENT TO A DEVICE, FIXTURE OR PIECE OF EQUIPMENT INDICATES EXISTING ITEM TO REMAIN. MAINTAIN EXISTING CONNECTIONS TO EQUIPMENT UNLESS NOTED OTHERWISE. N. PROVIDE QUALIFIED TRADES PERSON OR CONTRACTOR TO RESTORE FINISHED WALLS, CEILING AND FLOORS TO ORIGINAL CONDITION AS CALLED FOR IN DIV 01 - CUTTING AND PATCHING. 0. WHERE GENERAL CONSTRUCTION WILL CREATE DUST AND POTENTIAL FALSE SMOKE DETECTOR SIGNALS, THE CONTRACTOR SHALL COORDINATE FIRE ALARM SYSTEM SHUTDOWNS WITH CORNELL EH&S. VISIT SITE PRIOR TO SUBMITTING WRITTEN SHUTDOWN REPORT - TO CONFIRM EXISTING SMOKE DETECTOR LOCATION AND OWNERS' DEVICE/ZONE ADDRESS WITH RESPECT TO LOOK -AHEAD WORK SCHEDULE. REFER TO EXISTING FIRE ALARM DEVICE SCHEDULE, AS APPLICABLE. FALSE FIRE ALARMS CAUSED BY CONSTRUCTION DUST WILL NOT BE TOLERATED. CONTRACTORS ARE RESPONSIBLE TO PAY FOR ANY FINES IMPOSED BY ITHACA/CAYUGA HEIGHTS FIRE DEPARTMENT FOR UNNECESSARY FALSE FIRE ALARMS. P. RESTORE AND MAINTAIN AREA FIRE RESISTANCE RATING OF FLOOR AND WALLS. RESTORE AND MAINTAIN AREA SMOKE BARRIERS RATING OF WALLS AND SOFFITS WITH SIMILAR MATERIALS AS CALLED FOR IN DIV 01 - CUTTING AND PATCHING. ALSO REFER TO SPEC SECTION DIV 07 - PENETRATION FIRESTOPPING. Q. FIRESTOP ALL NEW AND EXISTING TELECOM WALL PENETRATIONS AND CONDUIT SLEEVES TO MAINTAIN AREA FIRE RESISTANCE RATING. R. MAINTAIN EXISTING SERVICES AT ALL TIMES DURING NORMAL BUILDING OPERATIONS. PROVIDE TEMPORARY SERVICES AS REQUIRED, OR AS DIRECTED. EXISTING DATA/COMMUNICATIONS CABLE AND OUTLETS SHALL REMAIN DURING THE INSTALLATION OF NEW CABLING AND DEVICES TO MINIMIZE DOWN TIME. COORDINATE CUTOVER TO NEW SYSTEM WITH PROJECT MANAGER. REFER TO SPEC SECTION 27 - COMMISSIONING. S. ALL TRADES AND CONTRACTS SHALL REPAIR DAMAGED CEILINGS (ANY TYPE), REPLACE LAY -IN CEILING TILES AND GRID WHERE NOTCHED OR DAMAGED FOR EXISTING REMOVALS OR NEW INSTALLATIONS, AS CALLED FOR IN DIV 01 - CUTTING AND PATCHING. REFER TO EXISTING CEILING SCHEDULE ON NEW WORK T2 DRAWINGS. T. PROVIDE BLANK COVERS, FIRE SEAL, CUTTING, AND PATCHING AS REQUIRED TO REPAIR HOLES, UNPAINTED AREAS, OR OTHER PHYSICAL DEFECTS CAUSED BY THE REMOVAL AND INSTALLATION OF EQUIPMENT AND DEVICES. U. PROVIDE ELECTRONIC SUBMITTAL(S) ON ACTUAL PRODUCTS USED VIA PROJECT WEBSITE. INCLUDE COPY OF APPROVED SUBMITTAL WITH CLOSE-OUT DOCUMENTS (IN HARD COPY 0/M MANUAL), REFER TO SECTIONS: 01 33 00 - SUBMITTALS; 01 78 39 - RECORD DOCUMENTS; AND 01 77 00 - PROJECT CLOSEOUT AS APPLICABLE. V. DIVISION 27 CONTRACTOR SCOPE: FOR ALL EXISTING SR -4 RACEWAY. THOROUGHLY WIPE DIRT AND DUST FREE FROM ALL REUSED EXISTING SR -4 SERIES RACEWAYS, REMOVE METAL FILINGS FROM INSIDE RACEWAYS AT ALL CONDUIT CONNECTIONS. WHEN RACEWAY IS SHARED WITH ELECTRIC, PROVIDE/MAINTAIN METALLIC SEPARATION BARRIERS, PER NEC CODE. AT LOCATIONS WITH EXISTING ROUND MODULAR OR 4 -PRONG OUTLETS, REMOVE/REPLACE EXISTING SR -4 COVER WITH NEW DEVICE COVER TO CLOSE THE OPEN HOLE (AND PRIME AND PAINT TO MATCH). AT LOCATIONS WITH EXISTING OPENINGS IN EXISTING SR -4, REMOVE/REPLACE EXISTING SR -4 COVER WITH NEW DEVICE COVER TO CLOSE THE OPEN HOLE (AND PRIME AND PAINT TO MATCH). REPLACE EXISTING BENT/DAMAGED OR MISSING SR -4 COVERS (ASSUME 10' OF NEW COVER FOR EVERY 150' OF. EXISTING RACEWAY, EVEN IF NOT SPECIFICALLY INDICATED ON THE DRAWINGS). W. CUTOVER OF ACTIVE BACKBONE SERVICES TO BE PERFORMED BY CIT FIELD SERVICES UNLESS OTHERWISE NOTED. END OF NOTES GENERAL REMOVAL NOTES A. AFTER VOICE/DATA CUTOVER, REMOVE EXISTING SURFACE MOUNTED COMMUNICATION OUTLETS AND ASSOCIATED CABLING UNLESS OTHERWISE NOTED TO REMAIN. PATCH AND PAINT AS CALLED FOR. PROVIDE BLANK COVER PLATE TO MATCH EXISTING AS REQUIRED. B AFTER VOICE/DATA CUTOVER, AT EXISTING RECESSED COMMUNICATION OUTLETS PROVIDE BLANK COVER PLATE. REMOVE ALL ASSOCIATED CABLING IN ITS ENTIRETY. PROVIDE BLANK COVER PLATE ON ALL EXISTING UNUSED OPENINGS AS WELL. C WHEN EXIST -NI: SURFACE RACEWAY IS CALLED TO REMAIN FOR REUSE, REMOVE EXISTING COMMUNICATIONS FACEPLATES AND OLD CABLING IN THEIR ENTIRETY, AFTER VOICE/DATA CUTOVER, AS CALLED FOR. PROVIDE BLANK PLATE OR REPLACEMENT COVER SECTIONS TO CONCEAL OPENINGS. RECYCLE REMOVED METALLIC COMPONENTS, RACEWAYS AND CABLING TO THE GREATEST EXTENT POSSIBLE. COORDINATE DUMPSTER LOCATION IN ADVANCE WITH THE PROJECT MANAGER. AFTER VOICE/DATA CUTOVER, REMOVE EXISTING CABLING BACK TO SOURCE. REMOVE ALL ASSOCIATED ANCHORS, TERMINAL BLOCKS, AND SPLICE CASES. COORDINATE THE CUTOVER OF ALL REMAINING SYSTEMS WITH THE PROJECT MANAGER. AFTER VOICE/ DATA CUTOVER, DISCONNECT AND REMOVE TERMINAL BLOCKS, ENCLOSURE, PLYWOCI) BACKBOARD, AND ALL ASSOCIATED CABLING IN THEIR ENTIRETY. PRIOR TO REMOVAL, THE CONTRACTOR SHALL TEST ALL PAIRS FOR SERVICE. COORDINATE THE CUTOVER OF ALL REMAINING SYSTEMS WITH THE PROJECT MANAGER. PATCH AND PAINT WALLS TO MATCH EXISTING AREA IN CORRIDORS AND OFFICE AREAS. G. DISCONNECT AND REMOVE ALL EXISTING DEVICES/WIRING SHOWN FOR REMOVAL, BACK TO SOURCE. MAKE ALL CONNECTIONS NECESSARY TO MAINTAIN EXISTING SYSTEMS WHERE PARTIAL DEMOLITION IS REQUIRED DUE TO SCHEDULING. H. REPLACE CEILING TILES AND CEILING GRID, TO MATCH EXISTING, WHERE NOTCHED FOR EXISTING CONDUITS AND RACEWAYS THAT ARE CALLED TO BE REMOVED. END OF NOTES GENERAL NEW WORK NOTES A. CABLE TRAY, CONDUIT AND RACEWAY ROUTING SHOWN IS DIAGRAMMATIC ONLY. CONTRACTOR TO FIELD VERIFY EXISTING CONDITIONS AND ROUTE PATHWAYS TO AVOID MECHANICAL AND STRUCTURAL CONFLICTS. NOT ALL REQUIRED JUNCTION BOXES AND OFFSETS ARE SHOWN, PROVIDE OFFSETS AND PULLBOXES AS REQUIRED. B. CONTRACTOR SHALL REMOVE AND REPLACE SPLINE CEILINGS TO ACCESS WORK AREAS AS INDICATED ON THE T2-x.CP_CA DRAWINGS. CONTRACTOR SHALL ALSO PROVIDE ACCESS PANELS AT ALL NEW PULLBOXES INSTALLED IN SPLINE CEILINGS. C. WHERE EXISTING PATHWAYS ARE TO REMAIN AND BE REUSED, THE CONTRACTOR SHALL RE -SUPPORT AND PROVIDE RADIUS FITTINGS AS NEEDED TO ENSURE COMPLIANCE WITH SPECIFICATIONS AND UNIVERSITY STANDARDS. D. A PULLBOX SHALL BE INSTALLED FOR RACEWAYS, SIZED AS INDICATED, IN RACEWAY INCREMENTS OF 100 FEET, AND WHEN THE ACCUMULATIVE BEND RADII IS EQUIVALENT TO 180 DEGREES. INSTALL CONDUITS THROUGH PULLBOXES ONLY AS DEPICTED ON STANDARD DETAILS, AND T2-x.CA_CP SERIES DRAWINGS. E. LOCATIONS OF PULLBOXES SHOWN ARE APPROXIMATE - PULLBOXES SHALL BE LOCATED IN AN AREA THAT IS READILY ACCESSIBLE. FIELD VERIFY THE EXACT LOCATIONS. F. THE USE OF CONDUIT BODIES (SMART LB'S) THAT HAVE BUILT-IN BEND RADIUS CONTROL DESIGNED FOR TELECOMMUNICATIONS APPLICATIONS ARE PERMITTED IN ALL COPPER, FIBER AND UTP RISER CONDUITS USED FOR TELECOMMUNICATIONS PATHWAYS. G. THE PULLING TENSION OF UTP CABLES SHALL NOT EXCEED 25 LBS PER CABLE. PROVIDE ADDITIONAL INSTALLERS AT CORNERS AND UTILIZE APPROVED LUBRICANT AS REQUIRED. H. COORDINATE THE ROUTING OF ALL PATHWAYS WITH EXISTING DUCT WORK, PIPING, ELECTRICAL CONDUITS, AND OTHER EXISTING OBSTRUCTIONS. I. PROVIDE ALL REQUIRED OFFSETS, FABRICATION AND FITTINGS REQUIRED FOR THE INSTALLATION OF CABLE TRAY, CONDUIT, SURFACE RACEWAY, AND CABLE RUNWAY. J. CABLE TRAY AND CONDUIT SHALL BE INSTALLED CONCEALED UNLESS OTHERWISE NOTED. K. PAINT EXPOSED CONDUITS, SUPPORTS, PULLBOXES, ETC. REFER TO DIV 09 - INTERIOR PAINTING. END OF NOTES J:\PROJECTS-Ithaca\2011\11103 CORNELL - NCP\Kroch Library 2047A\ CAD\ 11103-2047A--T-GEN.dwq GENERAL DRAWING NOTES -EXISTING CONDITIONS/REMOVALS- A. ITEMS SHOWN GRAYSCALE ARE EXISTING TO REMAIN UNLESS SPECIFIED OTHERWISE. B. ITEMS SHOWN DASHED -BOLD ARE TO BE REMOVED UNLESS SPECIFIED OTHERWISE. C. EXISTING CONDITIONS HAVE BEEN DOCUMENTED TO THE EXTENT POSSIBLE AT TIME OF SURVEY. TRUST BUT VERIFY ALL EXISTING CONDITIONS ARE AS INDICATED ON "T" SERIES DRAWINGS. REDLINE ON RECORD DRAWINGS ANY DEVIATIONS. END OF NOTES GENERAL DRAWING NOTES -HORIZONTAL CABLING - A. ITEMS SHOWN BOLD ARE NEW WORK UNLESS SPECIFIED OTHERWISE. B. ITEMS SHOWN IN GRAYSCALE ARE EXISTING TO REMAIN UNLESS SPECIFIED OTHERWISE. C. PROVIDE MANUFACTURER ENGINEERED SOLUTION FOR SMOKE AND FIRE STOPS. D. REFER TO DRAWINGS T1 -CL, T1 -FL, T3-xx, AND SPECIFICATIONS 27 13 00, 27 15 00, 27 05 00, 27 05 53 FOR ADDITIONAL REQUIREMENTS. E. PROVIDE CAT 6A CABLING FOR ALL OUTLETS LOCATIONS WITH A WAP OUTLET DESCRIPTOR. PROVIDE CAT 6 CABLING FOR ALL OTHER OUTLET LOCATIONS WITH NEW CABLING INDICATED. F. ALL NEW CAT 6 AND CAT 6A CABLING SHALL BE NON PLENUM CMR RATED. G. BACKBONE CABLING AND HORIZONTAL CABLING SHALL NOT OCCUPY THE SAME CONDUIT / CABLE TRAY UNLESS APPROVED BY OWNER. END OF NOTES GENERAL DRAWING NOTES -PATHWAYS- A. ITEMS SHOWN BOLD ARE NEW WORK UNLESS SPECIFIED OTHERWISE. B. ITEMS SHOWN IN GRAYSCALE ARE EXISTING TO REMAIN UNLESS SPECIFIED OTHERWISE. C. REFER TO DRAWINGS T2-x.CA_CP AND T1 -PL FOR HORIZONTAL PATHWAYS. D. REFER TO A-, M-, E -SERIES DRAWINGS FOR ADDITIONAL REQUIREMENTS. E. REFER TO T1 -PL DRAWING FOR ADDITIONAL REQUIREMENTS. F. PATCH/FIRESTOP ALL EXISTING AND NEW CONDUIT CABLE PENETRATIONS IN CORRIDOR WALLS. G. REMOVE LIGHTS AS REQUIRED TO ACCESS ABOVE CEILING LOCATIONS. REPORT ANY EXISTING DAMAGED OR NON -OPERATIONAL LIGHTS TO OWNER'S REPRESENTATIVE PRIOR TO LIGHT REMOVAL. H. EMT TO BE USED IN ALL NEW CONDUIT INSTALLATIONS IF POSSIBLE. FLEX CONDUIT TO BE USED AS LAST RESORT IF FIELD CONDITIONS PREVENT USE OF EMT. IF FLEX CONDUIT IS TO BE USED, IT SHALL BE INCREASED TO ONE TRADE SIZE LARGER THAN REQUIRED FOR EMT. I. PROVIDE BUSHINGS FOR ALL CONDUIT ENDS INSIDE EXISTING & NEW PULLBOXES. J. RE -CONNECT ANY EXISTING CONDUIT BEING REUSED THAT HAS SEPARATED FROM FITTING. K. PERMANENT LABEL NEAT AND LEGIBLE, ALL NEW AND EXISTING PULLBOX COVERS WITH "COMMUNICATIONS ONLY". L. ALL NEW RACEWAY TO BE METALLIC UNLESS OTHERWISE NOTED. M. PROVIDE SPACE SAVER CONDUIT CONNECTORS IN NEW OUTLET BOXES, RACEWAYS AND PULLBOXES. REFER TO SECTION 27 05 28. N. WHERE INDICATED ON THE DRAWINGS, PAINT EXPOSED CONDUITS, SUPPORTS, PULLBOXES, ETC. WHERE INSTALLED IN FINISHED (PUBLIC) NON-MECHANICAL AREAS. REFER TO DIV 09, INTERIOR PAINTING. 0. ALL OUTLETS THAT ARE CALLED TO BE RECESS MOUNTED SHOULD BE IN A DOUBLE GANG BOX. ALL OUTLETS THAT ARE FED VIA SR -2 RACEWAY SHOULD BE ASSUMED TO BE SINGLE GANG SURFACE MOUNT OUTLET BOXES UNLESS OTHERWISE NOTED. P FOR ALL EMERGENCY AND WAI I PHONE IOCATIONS THAT CALL FOR SURFACE RACEWAYS ASSUME SR -7 AND ASSOCIATED FITTINGS. Q. ALL EXISTING AND NEW PATHWAYS THAT ARE 2" AND LARGER, AND LONGER THAN 10' SHALL BE BONDED. R. ALL CABLE TRAYS SHALL BE ELECTRICALLY CONTINUOUS. COMMUNICATIONS PATHWAYS THAT END IN CLOSE PROXIMITY TO THE CABLE TRAY SHALL BE BONDED TO THE CABLE TRAY. S. ALL PATHWAYS TERMINATING IN THE MTR\ITR SHALL BE BONDED TO THE TMGB\TGB. T. CABLES SUPPORTED IN J HOOKS SHALL FOLLOW THE J HOOK MANUFACTURERS REQUIREMENTS FOR MOUNTING, SPACING, AND FILL CAPACITY. END OF NOTES ACCESS CONTROL SYMBOLS LEGEND Cid CARD READER LOCK 0 DOOR CONTACT (POSITION SWITCH) SINGLE INPUT READER INTERFACE MODULE FER71 DUAL INPUT READER INTERFACE MODULE ❑i INTELLIGENT SYSTEM CONTROLLER (CONTROL PANEL) PATHWAY SCHEDULE - NEW WORK CABLE FILL BASED ON CABLE OD O = 0.24 DESIGNATION DESCRIPTION MANUFACTURER PART NO. APPROXIMATE OUTSIDE DIMENSION APPROXIMATE INSIDE DIMENSION CABLE FILL CAPACITY* MIN. BEND RADIUS .75" C = CONDUIT SEE SPEC. SECTION 27 05 28 .75" DIA. 4 4.5" 1" C 1" DIA. 7 6" 1.25" C 1.25" DIA. 13 7.5" 1.5" C 1.5" DIA. 18 9" 2" C 2" DIA. 29 12" 2.5" C 2.5" DIA. 51 25" 3" C 3" DIA. 78 30" 4" C 4" DIA. 130 40" ETR SR -1 NOT USED ELEVATOR PHONE SR -2 ** SURFACE RACEWAY SEE SPEC. SECTION 27 05 28 2400 SERIES SEE SPEC. SECTION 27 05 28 12 GWB SR -3 ** SURFACE RACEWAY 3000 SERIES 32 SR -4 ** SURFACE RACEWAY 4000 SERIES 63 SR -4D ** SURFACE RACEWAY (DIVIDED) 4000D SERIES 30 SR -5 ** SURFACE RACEWAY 5400 SERIES 32 SR -6 ** SURFACE RACEWAY 6000 SERIES 140 SR -6D ** SURFACE RACEWAY (DIVIDED) 6000D SERIES 63 SR -7 SURFACE RACEWAY 700 SERIES 2 SINGLE -MODE OPTICAL FIBER LI -A TRAY NOT USED 2"x6" 106 TELECOMMUNICATION GROUND BUS BAR CT -B 2"x12" 211 L I -C 2"x18" 316 CT -D 2"x24" 419 CT -E ETR 4"x12" 419 CT -F NOT USED 4"x18" 632 CT -G 4"x24" 844 CT -H 6"x12" 636 CT -I 12"x24" 1273 CT -J - - CT -K - - NOTES: 0 40% MAXIMUM FILL FOR CATEGORY 6 INDICATED (PER TIA / EIA 569-A). - CAT6A CABLING HAS AN OD OF 0.285. - REDUCE FILL RATIO BY 6% FOR EACH 90° BEND - ENSURE THAT FILL RATIOS ARE NOT EXCEEDED 3/4" CONDUIT SHALL ONLY BE ALLOWED AS SPECIFICALLY NOTED ON DRAWINGS. ** REDUCE CAPACITY BY 50% FOR THE FOLLOWING CONDITIONS: - WHEN CONNECTORS ARE MOUNTED WITHIN RACEWAY - WHEN NON -RADIUS FITTINGS RESTRICT CROSS-SECTIONAL AREA - WHEN RACEWAY IS DIVIDED AND SHARED WITH ELECTRIC ALTER EXISTING SURFACE RACEWAY TO PROVIDE AT LEAST TWO 16" SECTIONS OF REMOVABLE COVERS TO ALLOW CABLE ROUGH -IN WITHOUT CONFLIL I WITH EXISTING FURNITURE CONFIGURATIONS. ALSO REFER TO GENERAL NOTE "Z" ON T -GEN DRAWING FOR ADDITIONAL SCOPE FOR SURFACE RACEWAYS. WHERE REQUIRED BY RACEWAY CAPACITY, OR AS DIRECTED, PROVIDE SURFACE MOUNT EXTENSION BOX ON EXISTING RACEWAY OPENING TO PROVIDE ADEQUATE CAPACITY AND BEND RADIUS. ALSO REFER TO RACEWAY DERATING REQUIREMENTS AT LEFT. WHERE REQUIRED BY RACEWAY CAPACITY, OR AS DIRECTED, PROVIDE RETROFIT ENTRANCE END FI I I ING OR ALTER EXISTING BACKFED CONDUIT WITH A NEW SPACE SAVER CONNECTOR TO PROVIDE ADEQUATE CAPACITY AND BEND RADIUS FOR NEW CABLING. ALSO REFER TO RACEWAY DERATING REQUIREMENTS AT LEFT. FIELD VERIFY EXISTING CONDITIONS AND PROPOSE ALTERATIONS THAT MINIMIZE SERVICE DISRUPTION DURATION. PROVIDE ALL TEMPORARY PROVISIONS TO MAINTAIN EXISTING SERVICES. CONDUIT AND CABLE TRAY TO BE ROUTED CONCEALED UNLESS OTHERWISE NOTED. SCALES ON THIS DRAWING ACCURATE WHEN PLOTTED TO: ARCH El (30X42 IN.) CEILING SCHEDULE ® SUSPENDED LAY -IN CEILING ® OPEN CEILING © SPLINE CEILING ® SUSPENDED PLASTER CEILING ® SUSPENDED PLASTER CEILING O SUSPENDED GYPSUM CEILING ABBREVIATIONS ACM ASBESTOS CONTAMINATED MATERIAL AP ACCESS PANEL AHJ AUTHORITY HAVING JURISDICTION AWG AMERICAN WIRE GAUGE ARMM ARMORED RISER 24AWG MULTIPAIR CABLE BDF BUILDING DISTRIBUTION FRAME BICSI BUILDING INDUSTRY CONSULTING SERVICES INTERNATIONAL BSC BIO -SAFETY CABINET CCTV CLOSED CIRCUIT TELEVISION CIT CORNELL INFORMATION TECHNOLOGIES CMP COMMUNICATIONS PLENUM RATED CABLE - NEC CMR COMMUNICATIONS RISER RATED CABLE - NEC CTR CIT SUPPORTED EQUIPMENT CABINET WITH ZONE CABLING DDC DIRECT DIGITAL CONTROL SYSTEM DEMARC VERIZON DEMARCATION POINT DN DOWN DOM DEPARTMENT OWNED AND MAINTAINED EF ENTRANCE FACILITY EH&S ENVIRONMENTAL HEALTH AND SAFETY EM EMERGENCY PHONE EMS ENERGY MANAGEMENT SYSTEM ERL "ERL" ADJACENT TO A DEVICE, FIXTURE OR PIECE OF EQUIPMENT INDICATES AN EXISTING ITEM TO BE RELOCATED. DISCONNECT AND REMOVE THE ITEM. REMOVE ALL UNNECESSARY RACEWAY AND WIRING. REINSTALL AND RECONNECT ITEM AS REQUIRED. MAINTAIN SERVICES AS CALLED FOR. ETR "ETR" ADJACENT TO A DEVICE, FIXTURE OR PIECE OF EQUIPMENT INDICATES AN EXISTING ITEM TO REMAIN. MAINTAIN EXISTING CONNECTIONS TO EQUIPMENT UNLESS OTHERWISE NOTED. EV ELEVATOR PHONE FACP FIRE ALARM CONTROL PANEL FO/OF FIBER OPTIC / OPTICAL FIBER FH FUME HOOD GWB GYPSUM WALL BOARD IEEE INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS ITR INTERMEDIATE TELECOMMUNICATIONS ROOM JB JUNCTION BOX LAN LOCAL AREA NETWORK LEC LOCAL EXCHANGE CARRIER / TELCO LS LIFE SAFETY MM MULTI -MODE OPTICAL FIBER MTR MAIN TELECOMMUNICATIONS ROOM OFNR OPTICAL FIBER NON-METALLIC STRENGTH RISER RATED OSHA OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION PB PULL BOX PP PATCH PANEL RAP REMOTE ANNUNCIATION PANEL SM SINGLE -MODE OPTICAL FIBER TC TELECOMMUNICATIONS CONTRACTOR TELCO PUBLIC TELEPHONE COMPANY (VERIZON) TGB TELECOMMUNICATION GROUND BUS BAR TMGB TELECOMMUNICATIONS MAIN GROUNDING BAR TIA TELECOMMUNICATION INDUSTRY ASSOCIATION TR TELECOM MUNICATIOI' S ROOM TYP TYPICAL UNO UNLESS NOTED OTHERWISE UPS UNINTERRUPTIBLE POWER SUPPLY UTP UNSHIELDED TWISTED PAIR VIF VERIFY IN FIELD VOM VERIZON OWNED AND MAINTAINED WAP WIRELESS ACCESS POINT TELECOM SYMBOLS LEGEND (REV. 02/12) DEMO EXISTING NEW DESCRIPTION Eli iT TELECOM OUTLET - FLOOR BOX g T ® TELECOM OUTLET - CEILING MOUNTED <4 <11 .4 . TELECOM OUTLET - WALL MOUNTED CONDUITS SIZE AS INDICATED - --u— —J— J -HOOKS - WHERE INDICATED CD ] CONDUIT WITH BUSHINGS - TYPE & SIZE AS L [ ] [ 05/11 /12 INDICATED 50 DD 04/06/12 50% DD SUBMISSION PULLBOX: X = SIZE: 09/30/11 PB—X PSD PB—X PBX (5) SMALL, (M) MEDIUM, (L) LARGE LxWxH LxWxH LxWxH CONSTRUCTION DOCUMENTS LxWxH = DIMENSIONS IN INCHES 3 . FR- OWNER PROJECT NO: 754 CTR CHECKED BY: JLB cTR EQUIPMENT CABINET WITH ZONE CABLING SHEET TITLE: STANDARD SYMBOLS, NOTES, ABBREVIATIONS (T—SERIES) T -GEN 1\13 AP] AP ACCESS PANEL - CEILING MOUNT NsR-1 sR-# ®sR-# VERTICAL RACEWAY - DOWN (SR -2 UNO) HsR-# eSR-# HsR-# VERTICAL RACEWAY - UP (SR -2 UNO) N,Cr x WCT-x C -X VERTICAL CABLE TRAY - DOWN Hcr x ICT -X HCt-x VERTICAL CABLE TRAY - UP • • • CONDUIT/SLEEVE - UP > 0 0 CONDUIT/SLEEVE - DOWN 4 0 0 CONDUIT/SLEEVE - THRU (BETWEEN FLOORS) HORIZONTAL RACEWAY - SIZED PER PATHWAY MX I sR # I ® SCHEDULE HORIZONTAL CABLE TRAY - SIZED PER CT -X CT -X CT -X PATHWAY SCHEDULE IIII IIII IIII CABLE RUNWAY T 1#+ SPLICE CASE ® P ® COMMUNICATIONS POWER POLE SERVING ZONE OR MTR/ITR BOUNDARY CTR SERVING ZONE BOUNDARY NEW / EXISTING OUTLET SUBSCRIPT KEY (REFER TO ADDITIONAL DESCRIPTORS THIS DRAWING) "A" ROOM LOCATION CODE 11 11 EXISTING OUTLET NOTE "xx" EXISTING PATHWAY TYPE TO BE REUSED "yy'" OUTLET DESCRIPTOR "zz" NEW PATHWAY TYPE 4xxzAl YY® NEW PATHWAY TYPE KEY CC CONDUIT TO CEILING CF CONDUIT TO FLOOR CL CONDUIT TO CLOSET CI CONDUIT HOMERUN TO ITR/MTR CP CONDUIT TO PULLBOX CT CONDUIT TO CABLE TRAY FW FISHABLE WALL JP J- HOOK TO PULLBOX JS J -HOOK TO SLEEVE JT J -HOOK TO CABLE TRAY PT PULLBOX TO CABLE TRAY SC SURFACE RACEWAY TO CEILING SF SURFACE RACEWAY TO FLOOR SH SURFACE RACEWAY TO HALL (RACEWAY THROUGH ROOM TO HALLWAY PRIMARY HORIZONTAL PATHWAY) SW SURFACE THROUGH WALL BOB NEW DEVICE OPENING IN EXISTING SURFACE RACEWAY, WITH BLANK PLATE (MATCH EXISTING COLOR) NOTE: PROVIDE MINIMUM 1" CONDUIT UNLESS NOTED OTHERWISE. INCREASE SIZE AS REQUIRED PER CABLE FILL CHART. NOTE: PROVIDE MINIMUM SIZE METALLIC RACEWAY BASED ON CABLE FILL CHART UNLESS NOTED OTHERWISE. NOTE: ASSUME PATHWAY TYPE "CP" UNLESS NOTED OTHERWISE. OUTLET DESCRIPTOR KEY ##" HEIGHT ABOVE FINISHED FLOOR (AFF) - EXAMPLE: 48" BAC BUILDING ACCESS CONTROLLER EM EMERGENCY TELEPHONE OUTLET EV ELEVATOR TELEPHONE LINE CONNECTION EMS ENERGY MANAGEMENT FACP FIRE ALARM CONTROL PANEL P WALL MOUNTED PAY -PHONE OUTLET W WALL MOUNTED TELEPHONE OUTLET TO BE MOUNTED AT 48" AFF WAP WIRELESS ACCESS POINT - REFER TO DETAIL AT -27052839. EXISTING OUTLET NOTE KEY A EXISTING DEVICE OR OPENING WITH LEGACY CABLING. REMOVE " CABLING, PAINT/PATCH OR PROVIDE BLANK AS APPLICABLE. EXISTING ONE -GANG BOX AND PATHWAYS TO BE REUSED AS ZN INDICATED. MAINTAIN EXISTING SERVICES UNTIL AFTER CUTOVER, THEN REMOVE CABLING. EXISTING TWO -GANG BOX AND PATHWAYS TO BE REUSED AS INDICATED. MAINTAIN EXISTING SERVICES UNTIL AFTER CUTOVER, THEN REMOVE CABLING. E STING OUTLET LOCATION IN SURFACE RACEWAY. PATHWAYS TO BE REUSED AS INDICATED. MAINTAIN ANY EXISTING SERVICE UNTIL AFTER CUTOVER, THEN REMOVE CABLING. PROVIDE DEVICE BRACKETS AS REQUIRED. A\ EXISTING PATHWAYS, BOXES, RACEWAYS AND CAT.5, CAT.5E OR CAT.6 CABLES TO REMAIN. EXISTING PATHWAYS, BOXES AND RACEWAYS TO REMAIN. COORDINATE SHUTDOWN AND CONDUIT/CABLE REWORK TO A\ RELOCATE FROM EXISTING TR TO NEW TR PER T1 -PL, T1 -SZ AND APPENDIX A. REASSIGN CABLE PANEL/PORTS AS CALLED FOR. CABLING SYMBOLS LEGEND 2B -101-A 1 CABLE IDENTIFICATION LABEL: 2B COMMUNICATIONS EQUIPMENT ROOM 101 MASTER LOCATION CODE A ROOM LOCATION CODE 1 POSITION IP � 115 METRO PHONE: ARCH -TECHNOLOGY, LLC www.archi-technology. corn PARK ROCHESTER, NY 14623 585.424.1952 Fax: 585.424.4239 Q N iiC) N c Q r ° z I Q U U oQ cc = ~ IIS ce w II z D w z Cc o U CLIENT: =�I�fd[�� Cornell University PROJECT C NETWORK r CONNECTIVITY CD 06/29/12 CONSTRUCTION DOCUMENTS 100 DD 05/11 /12 100% DD SUBMISSION 50 DD 04/06/12 50% DD SUBMISSION 20 SD 09/30/11 20% SD SUBMISSION PSD 09/07/11 PRELIMINARY SD SUBMISSION MARK DATE DESCRIPTION CONSTRUCTION DOCUMENTS ISSUE DATE: 06/29/12 3 . AT PROJECT NO: 11103-2047A OWNER PROJECT NO: 754 DRAWN BY: LP/EL/PKB CHECKED BY: JLB PROJECT MANAGER: GHS SHEET TITLE: STANDARD SYMBOLS, NOTES, ABBREVIATIONS (T—SERIES) T -GEN PLOT DATE: (\t, (\t, J UP UP 100SP ! 00U BOOST 100CR1 DN UP ////////////////////////////r 100UM D / , 00CM FC— DN J 160 I 1 1 ■ 1 100SK 1000J t t l a M t 11 1 t 1 GOUK 1OOJD 10010 NW. 100CK OPEN TO BELOW 100CT 1000T 190 1000R EX. PANEL PMR //////////////////////7////, 7////////, 100UN / V/////7/////1_ 100UP UP 100SR )TO UPPER MECHANICAL ROOM t ■ N 1 1 1 d r 100TE L_ J 100CL I 182 / 181 F 190A 100E8 1000L� 180 179 N u 0 UP 11 d r 100SN 190B u 100SH 100CP DN UP 1111 11111 i=tel :11 111111111 178 177 100CG FIRST FLOOR ELECTRICAL — NEW WORK Scale: 3/32" = 1'-0" 0 4' 8' 16' 100EA OPEN TO BELOW r / DN 100SG 171 172 10OCJ 173 174 i 1 1 1 1 b 100EC 176 / 176A 175A' 175 FIRST FLOOR BASEMENT 100SR 1M9OA 100SN DN FIRST MEZZANINE FLOOR ELECTRICAL — NEW WORK Scale: 3/32" = 0 4' 8' 16' ELECTRICAL CONSTRUCTION KEYED NOTES: PMR, SPARE— GENERAL NOTES . REFER TO DRAWING T1—AMEP. FIRST FLOOR MEZZANINE KEY PLAN Ei PROVIDE WIRING TO PUMP P-7, (2)#10 AWG WITH (1) #10AWG GROUND, IN 3/4" CONDUIT. E2 PROVIDE STARTER WITH DISCONNECT SWITCH AND ON—OFF AUTO CONTROL SWITCH. PROVIDE (2)#10 AWG WITH (1)#10 AWG GROUND, 3/4"C TO PUMP P-7 AND TO PANEL PMR, SPARE -1. PUMP P-7 SHALL RUN WHEN EITHER FC -1 OR FC -2 IS OPERATING AND STARTER IS IN "AUTO" MODE. E3 PROVIDE (2) #10 AWG WITH (1) #10AWG GROUND FROM FC -1 AND FC -2 AUX. RELAY TO P-7 STARTER. EX GROUND BUS — #4 AWG (ETR) r ROOM 100UN NEW GROUND BAR ITR -1A RM. 1000K FIRST FLOOR #4 AWG (ETR) L NEW GROUND BAR #6 AWL_ ' GB MTR—BA STEEi. RM. BOOUK BASEMENT #4 AWG (ETR) SUB -BASEMENT GROUND BAR (ETR) RM. 2BOOUK SUB -BASEMENT FIXTURE LAMPS REMARKS TYPE DESCRIPTION VOLTS MANUFACTURER & CATALOG NUMBER QTY. WATTS LAMP CODE FA 4 FT. SURFACE FLUORESCENT WITH HIGH IMPACT ACRYLIC LENS AND ELECTRONIC BALLAST 120/277 LITHONIA CLM-232—MVOLT—GEB 2 32 003218/835 1,2,3 FB 2 FT. SURFACE FLUORESCENT WITH HIGH IMPACT ACRYLIC LENS AND ELECTRONIC BALLAST 120/277 LITHONIA LB-217—MVOLT— GEB101 S 2 17F017T8/835 1,2 EM TWIN HEAD EMERGENCY LIGHTING UNIT 120/277 CFX6McPHILBEN 2 5 HALOGEN NOTES: 1. FURNISH WITH <10% THD ELECTRONIC BALLAST. 2. FURNISH WITH HIGH IMPACT PRISMATIC DIFFUSER. 3. PROVIDE 24" PENDANT LIGHTING FIXTURE SCHEDULE Scale: NONE GROUNDING SYSTEM RISER DIAGRAM Scale: NONE TMGB OR TGB LABEL ( P) PROVIDE ENGRAVED TAG FOR EACH GROUNDING CONDUCTOR, BOTH ENDS AND AT EXPOSED PASS THROUGH MECHANICAL SPACES AND AT ENTRANCES/ EXITS TO SHAFTWAYS, TYPICAL. DIV. 26 CONTRACTOR TO PROVIDE INSULATED TIN PLATED TELECOM SYSTEM GROUND BUS BAR. HOLE CENTERS TO MATCH LUG CONFIGURATION AND EIA/TIA 607 STANDARDS. REFER TO SECTIONS 260526 and 271100. TMGB — ERICO/ERITECH # TMGB—A20L27PT TGB — ERICO/ERITECH # TGB—A20L12PT 0 INSULATORS. O 5/8" LOCKWASHERS. O WALL MOUNTING BRACKET. O 5/8-11X1" H.H.C.S. BOLTS. 0 DIV. 26 CONTRACTOR TO PROVIDE LONG BARREL COMPRESSION LUG, TWO BOLT, COMPRESSION LUG (BURNDY HYLUG YAZ SERIES) OR EQUAL. PROVIDE A MINIMUM OF EIGHT (8) SPARE LUGS WITH 5/16" HOLES FOR FUTURE USE BY OWNER. DRILL AND TAP AS REQUIRED. SCRUFF BAR AND PROVIDE ANTIOXIDANT AS CALLED FOR. REFER TO SECTIONS 260526 and 271100. TELECOMMUNICATIONS GROUND BAR (TMGB \ TGB) DETAIL Scale: NONE J:\PROJECTS—Ithaca\2011 \ 11103 CORNELL — NCP\Kroch Library 2047A\CAD\ 1 1 103-2047A--AMEP.dwQ SCALES ON THIS DRAWING ACCURATE WHEN PLOTTED TO: ARCH El (30X42 IN.) SP I Wi 115 METRO PHONE: ARCHITECHNOLOGY, LLC www.archi-technology.com PARK ROCHESTER, NY 14623 585.424.1952 Fax: 585.424.4239 IIABE�SLEY DESIGN Architecture, 5789 Widewaters Dewitt, New Engineering, Landscape Architecture, P.C. Ph 31S.472.6980 Parkway Fax 315.472.3523 York 13214 E -Mail EDAt►$zartislep.cnm r Q N 41- o N >- C C >-- m Z J = Q U Q flC I- LI .J LU v, c -1 / Z D J zU ce0 o U CLIENT: Cornell University PROJECT 0( ut, NETWORK .:91 z 7,. • CONNECTIVITY CD 06/29/12 CONSTRUCTION DOCUMENTS 100 DD 05/11/12 100% DD SUBMISSION 50 DD 50% DD SUBMISSION 20 SD 20% SD SUBMISSION PSD 08/10/11 PRELIMINARY SD SUBMISSION MARK DATE DESCRIPTION CONSTRUCTION DOCUMENTS ISSUE DATE: 06/29/12 co I- : - cr i ` , S &;: AT PROJECT NO: 11103-2047A OWNER PROJECT NO: 754 DRAWN BY: LP/EL/PKB CHECKED BY: JLB PROJECT MANAGER: GHS SHEET E ECTRICAL TITLE: DETAI S PLOT BY: pba PLOT DATE: June 19, 2012 (4) 4"C UP AND DOWN 1 1 i f f f 1 1 1 1 1 1 1 (ETR BOOUK (ETR) (ETR) 1 1 1 1 1 1 BOOJD 1 BASEMENT MDF (ROOM BOOUK) ARCHITECTURAL -EXISTING / DEMO Scale: 1/2" = 1'-0" 0 1' 2' 4' (4) 4"C UP AND DOWN 1 1 1 (ETR) (ETR) (ETR)/4se 1 1 1 1 1 1 1 1 1 1 1 1 1 BOOJD BASEMENT MTR-BA (ROOM BOOUK) ARCHITECTURAL - NEW WORK Scale: 1/2" = 1'-0" 0 1' -s 2' 4' ARCHITECTURAL - CO \1STRUCTION KEYED NOTES: Al PROVIDE DOOR SWEEPS. FOR 1 INCH GAP OR LESS SWEEP SHALL BE PEMKO #293100CNB — CLEAR ANODIZED ALUMINUM W/GRAY NYLON BRUSH INSERT. FOR 1 INCH TO 1-3/8" GAP, PROVIDE PEMKO #18137CNB (SAME FINISH). 0 PROVIDE FIRESTOPPING AROUND (4) EXISTING 4" CONDUITS THROUGH FLOOR. NOTE: REFER TO DRAWING A4 FOR DETAILS AND SCHEDULES AS APPLICABLE. 11101111.1 SO= 11281116. RE= REMOVE GRILLE AND CAP EX. DUCT 8000K SPRINKLER (ETR) 800JD BASEMENT MDF (ROOM BODJK) MECHANICAL -EXISTING / REMOVALS Scale: 1/2" = 1'-0" 0 1' 2' 4` PB 1,13 (ETR) PB1,15 BOOJD EPMR,19 (ETR) EP R,21 BASEMENT MDF (ROOM BOOUK) ELECTRICAL -EXISTING / REMOVALS Scale: 1/2" = 1'-0" 0 1' 2' 4' SPRINKLER (ETR) BOOJ 3/4" CONDENSATE DN TO MOP SINK. TERMINATE 4" ABOVE MOP SINK. BASEM N -4T MTR-BA (ROOM BOOUK) 5 MECHANICAL - NEW WORK Scale: 1/2" = 1'-0" 0 1' 2' 4' BOOJD PANEL P81 (ETR) BASEMENT MTR-BA (ROOM BOOUK) ELECTRICAL - NEW WORK 6 Scale: 1/2" = 1'-0" 0 1' 2' 4' PB1,13 (ETR) PB1,15 HVAC CONSTRUCTION KEYED NOTES: 0 PROVIDE HIGH SIDEWALL CHILLED WATER FAN COIL UNIT. MOUNT BOTTOM OF UNIT APPROXIMATELY 9'-2" AFF. REFER TO DRAWING M4 FOR FOR UNIT SCHEDULE. NOTE: REFER TO DRAWING M4 FOR DETAILS AND SCHEDULES AS APPLICABLE. ELECTRICAL CONSTRUCTION KEYED NOTES: E1 REMOVE EX. GROUND BAR AND TURN OVER TO OWNER. E2 PROVIDE NEW TMGB AND ASSOCIATED GROUNDING PER DETAILS ON DRAWING E4. E3 PROVIDE EM LIGHT, CONNECT TO UNSWITCHED LEG OF EXISTING LIGHTING CIRCUIT. E4 PROVIDE CONVENIENCE OUTLETS AS INDICATED, AT 24" AFF. PROVIDE (1) 20A 1P BREAKER WITH (3) #12, 3/4"C. E5 RELOCATE EX. QUAD RECEPTACLES. EXTEND EX. BRANCH CIRCUIT WIRING AS REQUIRED. NOTE: REFER TO DRAWING E4 FOR DETAILS AND SCHEDULES AS APPLICABLE. GENERAL NOTES: A. REFER TO DRAWING AMEP—GEN FOR GENERAL NOTES. B. REFER TO DRAWINGS AMEP-1 A, M2 FOR CONTINUATION AND ADDITIONAL COORDINATION REQUIREMENTS. C. REFER TO DRAWING T3—BA FOR ADDITIONAL COORDINATION REQUIREMENTS. MTR—BA (RM. BOOUK) KEY PLAN J:\PROJECTS-Ithacat2011111103 CORNELL - NCP\Kroch Library 2047A\CAD\11103-2047A--T3-B.dwg SCALES ON THIS DRAWING ACCURATE WHEN PLOTTED TO: ARCH El (30X42 IN.) r Fre 4 04 abide 115 METRO PHONE: ARCH I -TECHNOLOGY, LLC www.archi-technology.com PARK ROCHESTER, NY 14623 585.424.1952 Fax: 585.424.4239 BEARDSLEY DESIGN Architecture, Engineering, Landscape Architecture, P.C. Ph 315.472.6988 5789 Widewaters Parkway Fax 315_472_3523 Dewitt, New York 13214 W*nail RDA@Reartisley.cem N 0 N >- Q Ct >-- 0° z _iii .. i Q U O Q 1 oC F- H (I) oCI W II Z __I ___I w zU oC O U CLIENT: Cornell University CONNECTIVITY PROJECT fir' i NETWORK 02 _ o4. CD 06/29/12 CONSTRUCTION DOOU IENTS 100 DD 05/11/12 100% DD SUBMISSION 50 DD 50% DD SUBMISSION 20 SD 09/30/11 20% SD SUBMISSION PSD 09/07/11 PRELIMINARY SD SUBMISSION MARK DATE DESCRIPTION CONSTRUCTION DOCUMENTS ISSUE DATE: 06/29/12 '' ! `<c <b_ ....OF NE Y . ".y41°- s 063155_ 063155 S►ONP�� AT PROJECT NO: 111.03-2047A OWNER PROJECT NO: 754 DRAWN BY: LP/EL/PKB CHECKED BY: JLB PROJECT MANAGER: GHS SHEET TITLE. MTR-BA PARTIAL PLANS AND KEYNOTES AmEp_BA 1 PLOT BY: pbarrie PLOT DATE: June 19, 2012 100UJ (4) 4"C UP AND DOWN 100U K (ETR) f , I 100JD FIRST FLOOR IDF (ROOM 100UK) ARCHITECTURAL -EXISTING / DEMO Scale: 1/2" = 1'-0" 0 1' 2' 4' MMEMIN 1000) (4) 4"C UP AND DOWN 1 4' , t r 4' 100U K (ETR) , , 4, 1 OOJ D FIRST FLOOR ITR -1A (ROOM 1000K) ARCHITECTURAL - NEW WORK Scale: 1/2" = 1'-0" 0 1' 2' 4' ARCHITECTURAL - CONSTRUCTION KEYED NOTES: Al PROVIDE DOOR SWEEPS. FOR 1 INCH GAP OR LESS SWEEP SHALL BE PEMKO #293100CNB — CLEAR ANODIZED ALUMINUM W/GRAY NYLON BRUSH INSERT. FOR 1 INCH TO 1-3/8" GAP, PROVIDE PEMKO #18137CNB (SAME FINISH). 0 PROVIDE FIRESTOPPING AROUND (4) EXISTING 4", AND (4) EXISTING 1" CONDUITS THROUGH FLOOR. NOTE: REFER TO DRAWING A4 FOR DETAILS AND SCHEDULES AS APPLICABLE. SPRINKLER (ETR) VAV & DUCTWORK (ETR) REMOVE GRILLE AND CAP EX. DUCT 00U K HWS&R — (ETR) / 1 P FIRST FLOOR IDF (ROOM 100UK) MECHANICAL -EXISTING / REMOVALS Scale: 1/2" = 1'-0" 0 1' 2' 4' 100JD 1 00UJ SPRINKLER (ETR) VAV & DUCTWORK (ETR) T HWS&R (ETR) FIRST FLOOR ITR-lA (ROO MECHANICAL - NEW WORK Scale: 1/2" = 1'-0" 0 1' 2' REFER TO DWG M2 FOR CONTINUATION 3/4" CHWS&R CLEAN OUT 3/4" CONDENSATE 00JD 3/4" CHWS&R REFER TO DWG M2 FOR CONTINUATION OOUK) 4' 3/4" CHWS&R DN TO MTR—BA, RM BOOUK 3/4" CONDENSATE DN TO MOP SINK. TERMINATE 4" ABOVE MOP SINK. HVAC CONSTRUCTION KEYED \TOTES: M 1 PROVIDE HIGH S1DEWALL CHILLED WATER FAN COIL UNIT. MOUNT BOTTOM OF UNIT APPROXIMATELY 7'-4" AFF. REFER TO DRAWING M4 FOR FOR UNIT SCHEDULE. NOTE: REFER TO DRAWING M4 FOR DETAILS AND SCHEDULES AS APPLICABLE. PANEL P1 (ETR) OOUJ 00U K (ETR) FIRST FLOOR IDF (ROOM 100UK) ELECTRICAL -EXISTING / REMOVALS Scale: 1/2" = 1'-0" 0 1' 2' 4' PANEL P1 (ETR) 1000) i (ETR) FIRST FLOOR ITR -1A (ROOM 100UK) ELECTRICAL - NEW WORK Scale: 1/2" = 1'-0" 0 1' 2' 4' EPMR,23 (ETR) ELECTRICAL CONSTRUCTION KEYED NOTES: E1 REMOVE EX. GROUND BAR AND TURN OVER TO OWNER. E2 PROVIDE NEW TGB AND ASSOCIATED GROUNDING PER DETAILS ON DRAWING E4. E3 PROVIDE EM LIGHT, CONNECT TO UNSWITCHED LEG OF EXISTING LIGHTING CIRCUIT. E4 PROVIDE CONVENIENCE OUTLETS AS INDICATED, AT 24" AFF UNLESS NOTED OTHERWISE PROVIDE (1) 20A 1P BREAKER WITH (3) #12, 3/4"C. E5 RELOCATE EX. QUAD RECEPTACLES. EXTEND EX. BRANCH CIRCUIT WIRING AS REQUIRED. NOTE: REFER TO DRAWING E4 FOR DETAILS AND SCHEDULES AS APPLICABLE. GENERAL NOTES: A. REFER TO DRAWING AMEP—GEN FOR GENERAL NOTES. B. REFER TO DRAWING M2 FOR CONTINUATION AND ADDITIONAL COORDINATION REQUIREMENTS. C. REFER TO DRAWING T3 -1A FOR ADDITIONAL COORDINATION REQUIREMENTS. ITR -1A (RM. 100UK) KEY PLAN J:\PROJECTS-Ithaca12011\11103 CORNELL - NCP\Kroch Library 2047A\CAD\11103-2047A--T3-1.dwg SCALES ON THIS DRAWING ACCURATE WHEN PLOTTED TO: ARCH El (30X42 IN.) immi Iii Einigib 115 METRO PHONE: ARCHI-TECHNOLOGY, LLC www.archi-technolo9Y .corn PARK ROCHESTER, NY 14623 585.424.1952 Fax: 585.424.4239 BEARDSLEY ADESIGN CES Architecture, Engineering, Landscape Architecture, P.C. Ph 315.472..6980 5789 Widewaters Parkway Fax 315_472_3523 Dewitt, New York 13214 E-mail SDAtnieardsley_csm r Q N 41- 0 N 1 >- CC Q c CO ›.- 1-4Z = Q U i in ce W > Z J W zU oC<O o U �c F— CLIENT: 0, upcup Cornell University PROJECT N— 8, 4 o A q� CONNECTIVITY NETWORK CD 06/29/12 CONSTRUCI iON DOCUMENTS 100 DD 05/11/12 100% DD SUBMISSION 50 DD 50% DD SUBMISSION 20 SD 09/30/11 20% SD SUBMISSION PSD 09/07/11 PRELIMINARY SD SUBMISSION MARK DATE DESCRIPTION CONSTRUCTION DOCUMENTS ISSUE DATE: 06/29/ 12 co �ef- e `<b 4,(:)F NEw y -04' ND N. CO� 0 � ` .f Nori$4....pris-, S O63153 , Vpr..4;oF, $1oN�'�' AT PROJECT NO: 11103-2047A OWNER PROJECT NO: 754 DRAWN BY: LP/EL/PKB CHECKED BY: JLB PROJECT MANAGER: GHS SHEET TITLE: ITR -1A PARTIAL PLANS AND KEYNOTES PLOT DATE: EXISTING 1-5/8" U—TRACK MTL. CHANNELS (BEYOND) #12 GA. WIRE TIES SUSPENDED FROM STRUCT. ABOVE (ALL FOUR CORNERS) 2-1 /2" MTL. FRAMING CHANNELS. SPAN BETWEEN EXISTING SUPPORTS (4—SIDES) 5/8" TYPE "X" GWB CONTINUOUS AROUND PERIMETER THREADED FASTENERS TO MTL. FRAMING EXISTING (RATED) CEILING ASSEMBLY. CEILING TILE ADHERED TO 1/2" GYPSUM BOARD NAILED TO 7/8" ALUM. V—GROOVE CHANNELS REMOVE AND REPLACE CEILING TILES AS REQUIRED FOR ACCESS PANEL INSTALLATION/RESTORATION ACCESS PANEL 2'—O" x 2-0" DOOR TYPICAL NOTE: SEE T2—xx.CA_CP DRAWINGS FOR ADDITIONAL LOCATIONS. PROVIDE ALL COSTS IN BASE BID. NEW ACCESS PANEL -EXISTING GWB CEILING Scale: NONE GENERAL NOTES . REFER TO DRAWING T1—AMEP. J:\PROJECTS—Ithaca\2011\ 11103 CORNELL — NCP\Kroch Library 2047A\CAD\ 1 1 103-2047A--AMEP.dwci SCALES ON THIS DRAWING ACCURATE WHEN PLOTTED TO: ARCH El (30X42 IN.) 'rte V4 01 &ffi.dib 115 METRO PHONE: ARCH1TECHNOLOGY, LLC www.archi-technology.com PARK ROCHESTER, NY 14623 585.424.1952 Fax: 585.424.4239 BEARDSLEYASOCIA DESIGNL Architecture, Engineering, Landscape Architecture, P.C. Ph 315.472..6980 5789 Widewaters Parkway Fax 315.472.3523 Dewitt, New York 13214 E-mail I3DAOBeartisley.cam r Q N ict0 N 1 >- (Y Q ce >-- CC) Z J ` = Q U Q C:c I -- I ce W z J __i LU zU Ct0 o U CLIENT: Cornell University yJ� CONNECTIVITY PROJECT ryd NETWORK cma� F CD 06/29/12 CONSTRUCTION DOCUMENTS 100 DD 05/11/12 100% DD SUBMISSION 50 DD 50% DD SUBMISSION 20 SD 20% SD SUBMISSION PSD 08/10/11 PRELIMINARY SD SUBMISSION MARK DATE DESCRIPTION CONSTRUCTION DOCUMENTS ISSUE DATE: 06/29/12 .*_°f NEwr -Mr, fa 'c*Op 06315'3 k, Vior....!. g10�� AT PROJECT NO: 11103-2047A OWNER PROJECT NO: 754 DRAWN BY: LP/EL/PKB CHECKED BY: JLB PROJECT MANAGER: GHS SHEET TITLE: ARCHITECTURAL DETAILS 0_ m 9 a- June 18.2U12 F - 0 UP 1 UP 0050 100CN —4 DN FC - 100S< 100U, 3/4" CONDENSATE 3/4" CHWS&R BOOS II 10QJS 1 0OUIV V PC 3/4" CHWS&R ii 3 UP II CHWS&R 100U T 10OUR //////////////////////////// 1000 UP 100SR 3/4" CHWS&R UP TO UPPER MECHANICAL ROOM V//////////// 100L P II II 617— 3/4" CHWS&R ROUTE AS HIGH AS POSSIBLE 00, 3/4" CONDENSATE DN TO MOP SINK. TERMINATE 4" ABOVE MOP SINK EX. — MOP SINK 3/4" CHWS&R — ON TO MTR—BA, RM BOOUK 100C< 3/4" CHWS&R OPEN TO BELOW 190 1000 182 181 80 II II UP 100S\ 79 FIRST FLOOR MECHANICAL - NEW WORK Scale: 1/8" = 0 4' 8' 16' OPEN TO BELOW II II OOEC 176 76A 175A/, GENERAL NOTES: A. REFER TO DRAWING AMEP—GEN FOR GENERAL NOTES. B. REFER TO AMEP—BA AND AMEP—SBA FOR FURTHER INFORMATION. HVAC CONSTRUCTION KEYED NOTES: 0 PROVIDE NEW PUMP (P-7). REFER TO DWG. M4 FOR PUMP SCHEDULE. NOTE: REFER TO DRAWING M4 FOR DETAILS AND SCHEDULES AS APPLICABLE. 10050 D\I 1 \A OOL M CIRCUIT — SETTER P-7 3/4" CHWS&R P-6 (ETR) P-5 (ETR) ISOLATION VALVE (TYP) 3/4" CHWS&R DN TO LOWER MECHANICAL ROOM FIRST MEZZANINE FLOOR ®MECHANICAL - NEW WORK Scale: 1/8" = 1'-0" 0 4' 8' 16' mmm EX. 6" CAMPUS CHWS TO REMAIN EX. 6" CAMPUS CHWR TO REMAIN ITR -1A BELOW (RM. 100UK) FIRST FLOOR MEZZANINE KEY PLAN ITR -1A (RM. 100UK) FIRST FLOOR KEY PLAN JAPROJECTS-Ithaca\2011111103 CORNELL - NCP\Kroch Library 2047A\CAD\M2-1.dwg SCALES ON THIS DRAWING ACCURATE WHEN PLOTTED TO: ARCH El (30X42 IN.) gam pip &lab 115 METRO PHONE: ARCHI-TECHNOLOGY, LLC www.archi-technology.corn PARK ROCHESTER, NY 14623 585.424.1952 Fax: 585.424.4239 Lib BEARDSLEY DESIGN I ow ASSOCIATES Architecture, Engineering, Landscape Architecture, P.C. Ph 315.472.6980 5789 Widewaters Parkway Fax 315.472.3523 Dewitt, New York 13214 E-mail BDA@Beardsley.com II II < N CD N ›- CC < ce 14 Z i < U U 0 < i (i) LU > z LU Z 0 u ce i -- II CLIENT: 0 NETWORK ft CONNECTIVITY Cornell University PROJECT -- CD 06/29/12 CONSTRUCTION DOCUMENTS 100 DD 05/11/12 100% DD SUBMISSION 50 DD 50% DD SUBMISSION 20 SD 09/30/11 20% SD SUBMISSION PSD 09/07/11 PRELIMINARY SD SUBMISSION MARK DATE DESCRIPTION CONSTRUCTION DOCUMENTS ISSUE DATE: 06/29/12 t.IL., (b, .(.0F NEykv IA, N. C(/ ° - ‘e- • *`''!". 063153 \,<<, AT PROJECT NO: 11103-2047A OWNER PROJECT NO: 754 DRAWN BY: LP/EL/PKB CHECKED BY: JLB PROJECT MANAGER: GHS SHEET TITLE: BASEMENT AND FIRST FLOOR PLAN -MECHANICAL PLANS M2 Cly PROVIDE ESCUTCHEON PLATES AT ALL PIPE PENETRATIONS EXPOSED TO VIEW. SIZE ESCUTCHEON AROUND INSULATION ON INSULATED PIPE AND AROUND PIPE ON UNISULATED PIPES PIPE , , \\\\\\\y PIPE INSULATION - BUTT TIGHT TO FIRESTOPPING SYSTEM xx FIRE RATED WALL SLEEVE WHERE REQUIRED BY SPECIFICATIONS PROVIDE FIRESTOPPING SYSTEM PER SPECIFICATIONS FIRE RATED WALL PENETRATION DETAIL Scale: NONE PROVIDE INSULATION SHIELD & INSERT FOR ALL PIPING BAND -HANGER RODS HANGER ROD INSULATION CHANNEL OR SIDE VIEW ANGLE TRAPEZE HANGER [-INSULATION I SHIELD AT HANGER PROVIDE HIGH COMPRESSIVE STRENGTH INSUL INSERT BETWEEN PIPE & INSULATION SHIELD ADJUSTABLE CLEVIS HANGER NOTE: REFER TO PROJECT SPECIFICATION FOR ROD DIAMETER, END CONDITION (CLAMP, ANCHOR, ETC.) HANGER TYPES, AND CONFIGURATION. HANGER ROD INSULATION WELD SADDLE ADJUSTABLE ROLLER HANGER PIPE HANGER Scale: NONE PROVIDE ESCUTCHEON PLATES AT ALL PIPE PENETRATIONS EXPOSED TO VIEW. SIZE ESCUTCHEON AROUND INSULATION ON INSULATED PIPE AND AROUND PIPE ON UNISULATED PIPES PIPE NON -FIRE RATED WALL SLEEVE WHERE REQUIRED BY SPECIFICATIONS f/�\\\\\\\\\\\ \ \\\ \\\\\\\\\\\\\\\\\\>1 PIPE INSULATION - RU'N INSULATION CONTINUOUS THROUGH WALL OPENING. /// A PROVIDE 1" CLEARANCE ALL AROUND NON -FIRE RATED WALL PENETRATION DETAIL Scale: NONE ISOLATION VALVE (TYPICAL) FLOW BALANCING VALVE COIL MANUAL AIR VEN T MV NOTES: 1. PIPING TO ALLOW REMOVAL OF COIL WITH OUT REMOVING PIPING BEYOND UNIONS OR FLANGES. STRAINER AIR FLOW PETE'S PLUGS (TYPICAL) -UNION FLANGE (TYPICAL) THERMOMETER (TYPICAL) f DRAIN W/HOSE END 2. FOR UNITS WITH MORE THAN ONE SECTION, PROVIDE FLOW BALANCER, UNIONS/ FLANGES, FLEXIBLE CONNECTORS, DRAINS AND AIR VENTS FOR EACH COIL. CHILLED WATER COIL PIPING DETAIL Scale: NONE PUMP SCHEDULE (P) UNIT LOCATION AREAS SERVED PUMP TYPE MEDIA PUMP HEAD PUMP FLOW (GPM) FLUID TEMP (F) MOTOR DATA DESIGN BASIS NOTES: VOLT PH HP SENSIBLE MBH P_� UPPER MECHANICAL ROOM MTR-BA & ITR -1A BOOSTER PUMP CHILLED WATER 25 3.0 45 120 1 1/6 � BELL & GOBBET PL -36 - 75 63 55 54 6.6 5.4 52 62 1.5 2.2 EMI WCP-09 1,2,3,4,5 FC -2 NOTES: 1. NOT USED (.8_1 Scale: NONE NEW PUMP UNIT SCHEDULE © °• .© . • CONCRETE DECK EXPANSION SHIELDS CONCRETE ANCHORS WASHER (TYPICAL) EXPANSION NAILS NOTE: REFER TO SPECIFICATION FOR REQUIRED ANCHOR CONFIGURATION. CONCRETE ANCHOR DEVICE DETAIL Scale: NONE COOLING COIL DRAIN SEE PLANS FOR CONTINUATION NOTE: L =INCH (MINIMUM) H =INCH PLUS THE TOTAL UNIT STATIC PRESSURE AT WORST CASE (LOADED FILTERS) UNDER POSITIVE PRESSURE COOLING COIL DRAIN SEE PLANS FOR CONTINUATION —\ CONNECT TO EXISTING COOLING COIL CONDENSATE DRAIN NOTE: L = H + J + PIPE DIAMETER H = 1 INCH FOR EACH INCH OF NEGATIVE PRESSURE* + 1 INCH J = H * NEGATIVE PRESSURE = TOTAL UNIT STATIC PRESSURE AT WORST CASE (LOADED FILTERS) MINUS EXTERNAL PRESSURE UNDER NEGATIVE PRESSURE CONNECT TO EXISTING L EXISTII V COOLING COIL CONDENSATE DRAIN TYPICAL COOLING COIL DRAIN Scale: NONE STRAINER ISOLATION VALVE (TYPICAL) 1/4„ -RETURN GENERAL NOTES 1. REFER TO DRAWING T1—AMEP. PRESSURE GAUGE (0#-100# PSI) SUPPLY TSD � TRIPLE DUTY VALVE UNION (TYPICAL) CIRCULATING PUMP IN LINE PUMP DIAGRAM DETAIL Scale: NONE Ufa IT LOCATION AIRFLOW ELECTRICAL CHILLED WATER COIL BEARDSLEY ASSOCIATESDESIGN MOTOR HP (WATTS) V PH FLA EDB EWB LDB LWB TOTAL MBH SENSIBLE MBH EWT LWT GPM FLUID PD MANUF/MAKE NOTES FC -1 ITR -1A 250 23 115 1 .64 75 63 55 54 6.6 5.4 52 62 1.5 2.2 EMI WCP-09 1,2,3,4,5 FC -2 MTR—BA 250 23 115 1 .64 75 63 55 54 6.6 5.4 52 62 1.5 2.2 EMI WCP-09 1,2,3,5 NOTES: 1. PROVIDE WALL MOUNTED THERMOSTAT. 2. PROVIDE FILTER 3. PROVIDE SMOOTH SQUARE BACKING BETWEEN BLOCK WALL AND UNIT TO ABSORB ANY VIBRATION. 4. PROVIDE CONDENSATE PUMP. 5. EWT = 52'F DURING WINTER MONTHS. EWT = 45' DURING SUMMER MONTHS. NEW CHILLED WATER FAN COIL UNIT SCHEDULE J:\PROJECTS—Ithaca\2011\ 11 103 CORNELL — NCP\Kroch Library 2047A\CAD\ 11103-2047A— —AMEP.dwa SCALES ON THIS DRAWING ACCURATE WHEN PLOTTED TO: ARCH El (30X42 IN.) r ism RPARCHI-TECHNOLOGY, ems& 115 METRO PHONE: LLC — www. arch i -technology. corn PARK ROCHESTER, NY 14623 585.424.1952 Fax: 585.424.4239 BEARDSLEY ASSOCIATESDESIGN Architecture, Engineering, Landscape Architecture, P.C. Ph 315.472.6980 5789 Widewaters Parkway Fax 315.472.3523 Dewitt, New York 13214 E -snail BMA/Beardsley-cern r Q N .11- 0 N IW ›.- ce Q cit Ea 1-1›-z = Q V 0 Q ce i r� V z D W Ct 0 CLIENT: (ci;u) ge Cornell University CONNECTIVITY PROJECT ® NETWORK 0 X - CD 06/29/12 CONSTRUCTION DOCUMENTS 100 DD 05/11/12 100% DD SUBMISSION 50 DD 50% DD SUBMISSION 20 SD 20% SD SUBMISSION PSD 08/10/11 PRELIMINARY SD SUBMISSION MARK DATE DESCRIPTION CONSTRUCTION DOCUMENTS ISSUE DATE: 06/29/12 �. 'Fpit, ,OF NE'r ot1DN.w`®I- r`, < ar 06315' ,. V.4), ...; S100 AT PROJECT NO: 11103-2047A OWNER PROJECT NO: 754 DRAWN BY: LP/EL/PKB CHECKED BY: JLB PROJECT MANAGER: GHS SHEET TITLE: MECHANICAL DETAILS M4 J BOOST 2800CM 111111111111111111 111111111111111111 11111110111IIII11 111111111111111111 111111111111111111 IIIIIIIIIIIIIIII 11111111111111111I . 111111111111111111 111111111111111111 28000K 280009 :1111111111111111 111811111111111111111 II11111111IIIII1111111 1111111111111111111111 p181111111111111181 111111181111111111111 1111111 W 111111111111 11111111111111111111 1111111111111111111 II 280009 28000E 2800UP 2800CL 2B00CG 2870A 2B00CH 280050 SUB BASEMENT - KEY PLAN Scale: 1/32" = 11-0" 1111111111111 1111111111111 00SP 0 16' 32' 64' 1005K 100EB -i 100SH 10008 100CG )1000H ) 10050 FIRST FLOOR -KEY PLAN Scale: 1/32" = 1'-0" 0 16' 32' 64' A 1110. Jlt1 80009 1llllh 111�� 1111111111 r _ 0OST - r 80009 80005 8000J =00UK BOOUL ;00E8 800SH 800CP 800EC B89 BASEMENT - KEY PLAN Scale: 1/32" = 1'-0" 0 16' 32' 64' 100SR m. 190009 1990A hEll 0059 I 111 E! i 1 1 1 t 1MOOEB f1M00SH 1M00EC MIL I I I 0 STIMSON 1975 19758 FIRST FLOOR MEZZANINE -KEY PLAN Scale: 1/32" = 1'-0" 0 16' 32' 64' l J:\PROJECTS—Ithaca\2011\11103 CORNELL — NCP\Kroch Library 2047A\CAD\11103-2047A--T1—SZ,dwg SCALES ON THIS DRAWING ACCURATE WHEN PLOTTED TO: ARCH El (30X42 IN.) r r.M &ma 115 PHONE: METRO ARCH1MTECHNOLOGY, LLC www.archi-technology.com PARK ROCHESTER, NY 14623 585.424.1952 Fax: 585.424.4239 ! ` ol 0 N I >- <C c o° ›- ~ Z I Q U U Q 0 r� v Cit W II z ) J W z Ce 0 U CLIENT: Cornell University PROJECT CONNECTIVITY NETWORK s CD 06/29/12 CONSTRUCTION DOCUMENTS 100 DD 05/11/12 100% DD SUBMISSION 50 DD 50% DD SUBMISSION 20 SD 20% SD SUBMISSION PSD 08/10/11 PRELIMINARY SD SUBMISSION MARK DATE DESCRIPTION CONSTRUCTION DOCUMENTS ISSUE DATE: 06/29/12 �.� <, .,OF NES •• WAD N. CUA %f- 06315S 4/ ,sow- AT PROJECT NO: 11103-2047A OWNER PROJECT NO: 754 DRAWN BY: LP/EL/PKB CHECKED BY: JLB PROJECT MANAGER: GHS SHEET TITLE: AMEP-AREAS OF WORK PLOT BY: pbarrie PLOT DATE: June 28, 2012 R E UNIVE NET ORK CONNECTIVITY PRO CH LIE.AY - 2047A PROJECT SITE PLAN GOLDWIN SMITH HALL 2013 ORRILL HA 2001 PLATFORM OLIN LIBRARY 2047 URIS LIBRARY 2010 PAVED PARKING PUS ST 2088 WILLARD STRAIGHT HALL 2020 BARNES HALL 2009 DRAWING INDEX DRAWING DESCRIPTION T -COVER DRAWING INDEX AND PROJECT SITE PLAN T -GEN STANDARD SYMBOLS, NOTES, ABBREVIATIONS (T -SERIES) T1 11 -SZ TR SERVING ZONES, PLAN VIEWS AND BLDG. SECTION VIEW T1 -PL PATHWAYS LOGICAL RISER DIAGRAMS T1 -CL COPPER LOGICAL RISER DIAGRAMS T1 -FL FIBER LOGICAL RISER DIAGRAMS T2 T2-SB.CA CP SUB -BASEMENT PATHWAYS AND CABLING T2-B.CA_CP BASEMENT PATHWAYS AND CABLING T2-1.CA_CP FIRST FLOOR PATHWAYS AND CABLING T2-1M.CA_CP FIRST FLOOR MEZZANINE PATHWAYS AND CABLING T3 T3 -BA MTR-BA ENLAP. QED PLANS AND ELEVATIONS T3 -1A ITR -1A ENLARGED PLANS AND ELEVATIONS AMEP AMEP-GEN TI-AMEP AMEP-AREAS OF WORK AMEP-BA MTR-BA PARTIAL PLANS AND KEYNOTES AMEP-1A ITR -1A PARTIAL PLANS AND KEYNOTES A4 ARCHITECTURAL DETAILS M4 MECHANICAL DETAILS E4 ELEC: I RICAL DETAILS M2 BASEMENT AND FIRST FLOOR PLAN -MECHANICAL PLANS CT J:\PROJECTS-Ithaca\2011111103 CORNELL - NCP\Kroch Library 2047A\CAD\11103-2047A--T-COVER.dwg SCALES ON THIS DRAWING ACCURATE WHEN PLOTTED TO: ARCH El (30X42 IN.) 1 ElletarrAlin 46m16 115 METRO PHONE: ARCHI-TECHNOLOGY, LLC www.archi-technology.com PARK ROCHESTER, NY 14623 585.424.1952 Fax: 585.424.4239 KROcH LIBRARY "x. 2047A ITHACA/ NY CLIENT: ‘-c..4-il.,,,, Cornell University PROJECT e, ,,tiiiip jI--, I 0 NETWORK ,_, ,„,;:, rPi , .L.,:_0,4/ CONNECTIVITY CD 06/29 ' 12 CONSTRUCTION DOCUMENTS 100 DD 05/11/12 100% DD SUBMISSION 50 DD 04/06/12 50% DD SUBMISSION 20 SD 09/30/11 20% SD SUBMISSION PSD 09/07/1 1 PRELIMINARY SD SUBMISSION MARK DATE DESCRIPTION CONSTRUCTION DOCUMENTS ISSUE DATE: 06/2.9/ 2 n2 y• 3 AT PROJECT NO: 11103-2047A OWNER PROJECT NO: 754 DRAWN BY: LP/EL/PKB CHECKED BY: JLB PROJECT MANAGER: GHS SHEET TITLE: DRAWING INDEX AND PROJECT SITE PLAN 0 0 GENERAL PROJECT NOTES A. REFER TO A-, E-, AND M -SERIES DRAWINGS FOR AMEP SYMBOLS AND ABBREVIATIONS. B. REFER TO SPECIFICATION (SPEC) SECTION: DIVISION (DIV) 01 WORK UNDER CONTRACT. C. THIS INFORMATION REPRESENTS EXISTING CONDITIONS BASED ON ORIGINAL DRAWINGS AND OBSERVED SITE CONDITIONS. THE CONTRACTOR SHALL FIELD VERIFY EXACT ROUTING, DIMENSIONS AND QUANTITIES. THE CONTRACTOR SHALL DISCONNECT, REMOVE AND RECYCLE/DISPOSE OF ALL EXISTING CABLING AND DEVICES THAT ARE NOT SCHEDULED FOR REUSE. D. RACEWAY, CONDUIT, CABLING AND ELECTRICAL/MECHANICAL PATHS ARE SHOWN FOR REFERENCE ONLY. EACH CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS AND SHALL DETERMINE BEST PATHS FOR NEW INSTALLATION THAT WILL CAUSE THE LEAST DISTURBANCE TO OCCUPIED SURROUNDINGS AND BUILDING OPERATIONS (INCLUDING EVENING CLASSES). E. EACH CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND PERFORM EXPLORATORY INVESTIGATIONS FOR CONCEALED CONDITIONS AS REQUIRED. EQUIPMENT LOCATIONS AND ROUTES ARE APPROXIMATE AND MINOR ADJUSTMENTS TO THE INSTALLATION WILL BE REQUIRED TO AVOID CONFLICTS WITH EXISTING EQUIPMENT, APPARATUS, AND OCCUPANTS' FURNITURE AND PERSONAL BELONGINGS. F, ALL DRAWINGS ARE SCHEMATIC IN NATURE. THE CONTRACTOR SHALL PROVIDE OFFSETS, ENTRANCE END FITTINGS, RADIUS FITTINGS, HANGERS, ANCHORS, SUPPORT, WIRING AND ACCESSORIES NECESSARY FOR A COMPLETE, OPERATIONAL INSTALLATION. G. IT IS THE RESPONSIBILITY OF EACH CONTRACTOR TO COORDINATE WORK SHOWN ON THEIR CONTRACT DOCUMENTS WITH THE WORK OF OTHER TRADES PRIOR TO SCHEDULING, SHUTDOWN, DEMOLITION, FABRICATION OR INSTALLATION OF ANY WORK OR EQUIPMENT. EQUIPMENT OR DEVICES THAT CANNOT CHANGE LOCATION SHALL TAKE PRECEDENCE OVER THOSE THAT CAN CHANGE LOCATION. H. ALL TRADES AND CONTRACTS ARE RESPONSIBLE TO REVIEW SITE-SPECIFIC CLASSROOM SCHEDULING (DAILY AND WEEKLY), SPECIAL EVENTS/CONFERENCES, UNIVERSITY ACADEMIC CALENDARS, UNIVERSITY CLOSING AND HOLIDAYS. FACTOR WORK SCHEDULING AND MANPOWER LOADING IN SUCH A WAY SO AS TO MINIMIZE STUDENT AND STAFF DISRUPTIONS. i. PROVIDE SCHEDULES AND ONGOING PROGRESS REPORT SUBMITTALS FOR DEMOLITION AND NEW CONSTRUCTION AS CALLED FOR. REFER TO DIV 01 - SUBMITTAL PROCEDURES, AND DIV 01 - PROJECT MEETINGS SPECIFICATION SECTIONS. J. ALL TRADES AND CONTRACTS ARE RESPONSIBLE FOR THEIR OWN DEMOLITION, TEMPORARY FACILITIES, SAFETY PROGRAMS, PATCHING, PAINTING, FIRESTOP, TRASH REMOVAL/DISPOSAL, ROUTINE CLEANING, SPECIAL TELECOMMUNICATION ROOM CLEANING AND FINAL CLEANING, AS CALLED FOR. REFER TO SPEC SECTIONS IN DIV 01 THROUGH AND INCLUDING DIV 09 AS APPLICABLE. K. WHEN DRY CUTTING PLASTER, GYPSUM, CONCRETE MASONRY UNITS OR PLYWOOD - PROVIDE APPROPRIATE DUST AND NOISE CONTROL TEMPORARY PARTITIONS AND MAINTAIN EGRESS AND FIRE ALARM SYSTEM OPERATION. PROVIDE ZIP -WALL DUST BARRIERS OR OTHER APPROPRIATE PROTECTION TO LOCALIZE CLEANUP AND MINIMIZE THE EXTENTS OF FIRE ALARM SHUTDOWNS AND PREVENT FALSE FIRE ALARMS FOR SMALL SCALE CUTTING AND DEMOLITION. WHERE GENERAL CONSTRUCTION WILL CREATE DUST AND DEBRIS, THE CONTRACTOR SHALL PROVIDE PROTECTIVE COVERING FOR FURNITURE, FURNISHINGS AND EQUIPMENT. L. "ERL" ADJACENT TO A DEVICE, FIXTURE OR PIECE OF EQUIPMENT INDICATES AN EXISTING ITEM TO BE RELOCATED. DISCONNECT AND REMOVE THE ITEM. REMOVE ALL UNNECESSARY RACEWAY AND WIRING. REINSTALL AND RECONNECT ITEM AS REQUIRED. M. "ETR" ADJACENT TO A DEVICE, FIXTURE OR PIECE OF EQUIPMENT INDICATES EXISTING ITEM TO REMAIN. MAINTAIN EXISTING CONNECTIONS TO EQUIPMENT UNLESS NOTED OTHERWISE. N. PROVIDE QUALIFIED TRADES PERSON OR CONTRACTOR TO RESTORE FINISHED WALLS, CEILING AND FLOORS TO ORIGINAL CONDITION AS CALLED FOR IN DIV 01 - CUTTING AND PATCHING. 0. WHERE GENERAL CONSTRUCTION WILL CREATE DUST AND POTENTIAL FALSE SMOKE DETECTOR SIGNALS, THE CONTRACTOR SHALL COORDINATE FIRE ALARM SYSTEM SHUTDOWNS WITH CORNELL EH&S. VISIT SITE PRIOR TO SUBMITTING WRITTEN SHUTDOWN REPORT - TO CONFIRM EXISTING SMOKE DETECTOR LOCATION AND OWNERS' DEVICE/ZONE ADDRESS WITH RESPECT TO LOOK -AHEAD WORK SCHEDULE. REFER TO EXISTING FIRE ALARM DEVICE SCHEDULE, AS APPLICABLE. FALSE FIRE ALARMS CAUSED BY CONSTRUCTION DUST WILL NOT BE TOLERATED. CONTRACTORS ARE RESPONSIBLE TO PAY FOR ANY FINES IMPOSED BY ITHACA/CAYUGA HEIGHTS FIRE DEPARTMENT FOR UNNECESSARY FALSE FIRE ALARMS. P. RESTORE AND MAINTAIN AREA FIRE RESISTANCE RATING OF FLOOR AND WALLS. RESTORE AND MAINTAIN AREA SMOKE BARRIERS RATING OF WALLS AND SOFFITS WITH SIMILAR MATERIALS AS CALLED FOR IN DIV 01 - CUTTING AND PATCHING. ALSO REFER TO SPEC SECTION DIV 07 - PENETRATION FIRESTOPPING. Q. FIRESTOP ALL NEW AND EXISTING TELECOM WALL PENETRATIONS AND CONDUIT SLEEVES TO MAINTAIN AREA FIRE RESISTANCE RATING. R. MAINTAIN EXISTING SERVICES AT ALL TIMES DURING NORMAL BUILDING OPERATIONS. PROVIDE TEMPORARY SERVICES AS REQUIRED, OR AS DIRECTED. EXISTING DATA/COMMUNICATIONS CABLE AND OUTLETS SHALL REMAIN DURING THE INSTALLATION OF NEW CABLING AND DEVICES TO MINIMIZE DOWN TIME. COORDINATE CUTOVER TO NEW SYSTEM WITH PROJECT MANAGER. REFER TO SPEC SECTION 27 - COMMISSIONING. ALL TRADES AND CONTRACTS SHALL REPAIR DAMAGED CEILINGS (ANY TYPE), REPLACE LAY -IN CEILING TILES AND GRID WHERE NOTCHED OR DAMAGED FOR EXISTING REMOVALS OR NEW INSTALLATIONS, AS CALLED FOR IN DIV 01 - CUTTING AND PATCHING. REFER TO EXISTING CEILING SCHEDULE ON NEW WORK T2 DRAWINGS. . PROVIDE BLANK COVERS, FIRE SEAL, CUTTING, AND PATCHING AS REQUIRED TO REPAIR HOLES, UNPAINTED AREAS, OR OTHER PHYSICAL DEFECTS CAUSED BY THE REMOVAL AND INSTALLATION OF EQUIPMENT AND DEVICES. PROVIDE ELECTRONIC SUBMITTAL(S) ON ACTUAL PRODUCTS USED VIA PROJECT WEBSITE. INCLUDE COPY OF APPROVED SUBMITTAL WITH CLOSE-OUT DOCUMENTS (IN HARD COPY 0/M MANUAL), REFER TO SECTIONS: 01 33 00 - SUBMITTALS; 01 78 39 RECORD DOCUMENTS; AND 01 77 00 - PROJECT CLOSEOUT AS APPLICABLE. V. DIVISION 27 CONTRACTOR SCOPE: FOR ALL EXISTING SR -4 RACEWAY, THOROUGHLY WIPE DIRT AND DUST FREE FROM ALL REUSED EXISTING SR -4 SERIES RACEWAYS, REMOVE METAL FILINGS FROM INSIDE RACEWAYS AT ALL CONDUIT CONNECTIONS. WHEN RACEWAY IS SHARED WITH ELECTRIC, PROVIDE/MAINTAIN METALLIC SEPARATION BARRIERS, PER NEC CODE. AT LOCATIONS WITH EXISTING ROUND MODULAR OR 4 -PRONG OUTLETS, REMOVE/REPLACE EXISTING SR -4 COVER WITH NEW DEVICE COVER TO CLOSE THE OPEN HOLE (AND PRIME AND PAINT TO MATCH). AT LOCATIONS WITH EXISTING OPENINGS IN EXISTING SR -4, REMOVE/REPLACE EXISTING SR -4 COVER WITH NEW DEVICE COVER TO CLOSE THE OPEN HOLE (AND PRIME AND PAINT TO MATCH). REPLACE EXISTING BENT/DAMAGED OR MISSING SR -4 COVERS (ASSUME 10' OF NEW COVER FOR EVERY 150' OF. EXISTING RACEWAY, EVEN IF NOT SPECIFICALLY INDICATED ON THE DRAWINGS). W. CUTOVER OF ACTIVE BACKBONE SERVICES TO BE PERFORMED BY CIT FIELD SERVICES UNLESS OTHERWISE NOTED. END OF NOTES GENERAL REMOVAL NOTES A. AFTER VOICE/DATA CUTOVER, REMOVE EXISTING SURFACE MOUNTED COMMUNICATION OUTLETS AND ASSOCIATED CABLING UNLESS OTHERWISE NOTED TO REMAIN. PATCH AND PAINT AS CALLED FOR. PROVIDE BLANK COVER PLATE TO MATCH EXISTING AS REQUIRED. B. AFTER VOICE/DATA CUTOVER, AT EXISTING RECESSED COMMUNICATION OUTLETS PROVIDE BLANK COVER PLATE. REMOVE ALL ASSOCIATED CABLING IN ITS ENTIRETY. PROVIDE BLANK COVER PLATE ON ALL EXISTING UNUSED OPENINGS AS WELL. CF TING; S iRFA .F RA .F. AY IS rAI I FD TORF AIN F,.., RFUS FM. V. FXI..TING COMMUNICATIONS FACEPLATES AND OLD C. WHEN �X.S, ;.... ..:L.:: , :C. ....C��l... .� �..`_....�M.... , FOR � .� �. �.E, R�,..O � E _...5 ... C _. M CABLING IN THEIR ENTIRETY, AFTER VOICE/DATA CUTOVER, AS CALLED FOR. PROVIDE BLANK PLATE OR REPLACEMENT COVER SECTIONS TO CONCEAL OPENINGS. D. RECYCLE REMOVED METALLIC COMPONENTS, RACEWAYS AND CABLING TO THE GREATEST EXTENT POSSIBLE. COORDINATE DUMPSTER LOCATION IN ADVANCE WITH THE PROJECT MANAGER. E. AFTER VOICE/DATA CUTOVER, REMOVE EXISTING CABLING BACK TO SOURCE. REMOVE ALL ASSOCIATED ANCHORS, TERMINAL BLOCKS, AND SPLICE CASES. COORDINATE THE CUTOVER OF ALL REMAINING SYSTEMS WITH THE PROJECT MANAGER. F. AFTER VOICE/DATA CUTOVER, DISCONNECT AND REMOVE TERMINAL BLOCKS, ENCLOSURE, PLYWOC-:) BACKBOARD, AND ALL ASSOCIATED CABLING IN THEIR ENTIRETY. PRIOR TO REMOVAL, THE CONTRACTOR SHALL TEST ALL PAIRS FOR SERVICE. COORDINATE THE CUTOVER OF ALL REMAINING SYSTEMS WITH THE PROJECT MANAGER. PATCH AND PAINT WALLS TO MATCH EXISTING AREA IN CORRIDORS AND OFFICE AREAS. G. DISCONNECT AND REMOVE ALL EXISTING DEVICES/WIRING SHOWN FOR REMOVAL, BACK TO SOURCE. MAKE ALL CONNECTIONS NECESSARY TO MAINTAIN EXISTING SYSTEMS WHERE PARTIAL DEMOLITION IS REQUIRED DUE TO SCHEDULING. H. REPLACE CEILING TILES AND CEILING GRID, TO MATCH EXISTING, WHERE NOTCHED FOR EXISTING CONDUITS AND RACEWAYS THAT ARE CALLED TO BE REMOVED. END OF NOTES GENERAL NEW WORK NOTES A. CABLE TRAY, CONDUIT AND RACEWAY ROUTING SHOWN IS DIAGRAMMATIC ONLY. CONTRACTOR TO FIELD VERIFY EXISTING CONDITIONS AND ROUTE PATHWAYS TO AVOID MECHANICAL AND STRUCTURAL CONFLICTS. NOT ALL REQUIRED JUNCTION BOXES AND OFFSETS ARE SHOWN, PROVIDE OFFSETS AND PULLBOXES AS REQUIRED. B. CONTRACTOR SHALL REMOVE AND REPLACE SPLINE CEILINGS TO ACCESS WORK AREAS AS INDICATED ON THE T2-x.CP_CA DRAWINGS. CONTRACTOR SHALL ALSO PROVIDE ACCESS PANELS AT ALL NEW PULLBOXES INSTALLED IN SPLINE CEILINGS. C. WHERE EXISTING PATHWAYS ARE TO REMAIN AND BE REUSED, THE CONTRACTOR SHALL RE -SUPPORT AND PROVIDE RADIUS FITTINGS AS NEEDED TO ENSURE COMPLIANCE WITH SPECIFICATIONS AND UNIVERSITY STANDARDS. D. A PULLBOX SHALL BE INSTALLED FOR RACEWAYS, SIZED AS INDICATED, IN RACEWAY INCREMENTS OF 100 FEET, AND WHEN THE ACCUMULATIVE BEND RADII IS EQUIVALENT TO 180 DEGREES. INSTALL CONDUITS THROUGH PULLBOXES ONLY AS DEPICTED ON STANDARD DETAILS, AND T2-x.CA_CP SERIES DRAWINGS. E. LOCATIONS OF PULLBOXES SHOWN ARE APPROXIMATE - PULLBOXES SHALL BE LOCATED IN AN AREA THAT IS READILY ACCESSIBLE. FIELD VERIFY THE EXACT LOCATIONS. F. THE USE OF CONDUIT BODIES (SMART LB'S) THAT HAVE BUILT-IN BEND RADIUS CONTROL DESIGNED FOR TELECOMMUNICATIONS APPLICATIONS ARE PERMITTED IN ALL COPPER, FIBER AND UTP RISER CONDUITS USED FOR TELECOMMUNICATIONS PATHWAYS. G. THE PULLING TENSION OF UTP CABLES SHALL NOT EXCEED 25 LBS PER CABLE. PROVIDE ADDITIONAL INSTALLERS AT CORNERS AND UTILIZE APPROVED LUBRICANT AS REQUIRED. H. COORDINATE THE ROUTING OF ALL PATHWAYS WITH EXISTING DUCT WORK, PIPING, ELECTRICAL CONDUITS, AND OTHER EXISTING OBSTRUCTIONS. I. PROVIDE ALL REQUIRED OFFSETS, FABRICATION AND FITTINGS REQUIRED FOR THE INSTALLATION OF CABLE TRAY, CONDUIT, SURFACE RACEWAY, AND CABLE RUNWAY. J. CABLE TRAY AND CONDUIT SHALL BE INSTALLED CONCEALED UNLESS OTHERWISE NOTED. K. PAINT EXPOSED CONDUITS, SUPPORTS, PULLBOXES, ETC. REFER TO DIV 09 - INTERIOR PAINTING. END OF NOTES GENERAL DRAWING NOTES -EXISTING CONDITIONS/REMOVALS- A. ITEMS SHOWN GRAYSCALE ARE EXISTING TO REMAIN UNLESS SPECIFIED OTHERWISE. ITEMS SHOWN DASHED -BOLD ARE TO BE REMOVED UNLESS SPECIFIED OTHERWISE. C. EXISTING CONDITIONS HAVE BEEN DOCUMENTED TO THE EXTENT POSSIBLE AT TIME OF SURVEY. TRUST BUT VERIFY ALL EXISTING CONDITIONS ARE AS INDICATED ON "T" SERIES DRAWINGS. REDLINE ON RECORD DRAWINGS ANY DEVIATIONS. END OF NOTES GENERAL DRAWING NOTES -HORIZONTAL CABLING - A. ITEMS SHOWN BOLD ARE NEW WORK UNLESS SPECIFIED OTHERWISE. B. ITEMS SHOWN IN GRAYSCALE ARE EXISTING TO REMAIN UNLESS SPECIFIED OTHERWISE. C. PROVIDE MANUFACTURER ENGINEERED SOLUTION FOR SMOKE AND FIRE STOPS. . REFER TO DRAWINGS T1 -CL, T1 -FL, T3-xx, AND SPECIFICATIONS 27 13 00, 27 15 00, 27 05 00, 27 05 53 FOR ADDITIONAL REQUIREMENTS. . PROVIDE CAT 6A CABLING FOR ALL OUTLETS LOCATIONS WITH A WAP OUTLET DESCRIPTOR. PROVIDE CAT 6 CABLING FOR ALL OTHER OUTLET LOCATIONS WITH NEW CABLING INDICATED. . ALL NEW CAT 6 AND CAT 6A CABLING SHALL BE NON PLENUM CMR RATED. . BACKBONE CABLING AND HORIZONTAL CABLING SHALL NOT OCCUPY THE SAME CONDUIT / CABLE TRAY UNLESS APPROVED BY OWNER. END OF NOTES GENERAL DRAWING NOTES -PATHWAYS- A. ITEMS SHOWN BOLD ARE NEW WORK UNLESS SPECIFIED OTHERWISE. B. ITEMS SHOWN IN GRAYSCALE ARE EXISTING TO REMAIN UNLESS SPECIFIED OTHERWISE. C. REFER TO DRAWINGS T2-x.CA_CP AND T1 -PL FOR HORIZONTAL PATHWAYS. D. REFER TO A-, M-, E -SERIES DRAWINGS FOR ADDITIONAL REQUIREMENTS. E. REFER TO TI -PL DRAWING FOR ADDITIONAL REQUIREMENTS. F. PATCH/FIRESTOP ALL EXISTING AND NEW CONDUIT CABLE PENETRATIONS IN CORRIDOR WALLS. G. REMOVE LIGHTS AS REQUIRED TO ACCESS ABOVE CEILING LOCATIONS. REPORT ANY EXISTING DAMAGED OR NON -OPERATIONAL LIGHTS TO OWNER'S REPRESENTATIVE PRIOR TO LIGHT REMOVAL. H. EMT TO BE USED IN ALL NEW CONDUIT INSTALLATIONS IF POSSIBLE. FLEX CONDUIT TO BE USED AS LAST RESORT IF FIELD CONDITIONS PREVENT USE OF EMT. IF FLEX CONDUIT IS TO BE USED, IT SHALL BE INCREASED TO ONE TRADE SIZE LARGER THAN REQUIRED FOR EMT. I. PROVIDE BUSHINGS FOR ALL CONDUIT ENDS INSIDE EXISTING & NEW PULLBOXES. J. RE -CONNECT ANY EXISTING CONDUIT BEING REUSED THAT HAS SEPARATED FROM FITTING. K. PERMANENT LABEL NEAT AND LEGIBLE, ALL NEW AND EXISTING PULLBOX COVERS WITH "COMMUNICATIONS ONLY". L ALL NEW RACEWAY TO BE METALLIC UNLESS OTHERWISE NOTED. M. PROVIDE SPACE SAVER CONDUIT CONNECTORS IN NEW OUTLET BOXES, RACEWAYS AND PULLBOXES. REFER TO SECTION 27 05 28. N. WHERE INDICATED ON THE DRAWINGS, PAINT EXPOSED CONDUITS, SUPPORTS, PULLBOXES, ETC. WHERE INSTALLED IN FINISHED (PUBLIC) NON-MECHANICAL AREAS. REFER TO DIV 09, INTERIOR PAINTING. 0. ALL OUTLETS THAT ARE CALLED TO BE RECESS MOUNTED SHOULD BE IN A DOUBLE GANG BOX. ALL OUTLETS THAT ARE FED VIA SR -2 RACEWAY SHOULD BE ASSUMED TO BE SINGLE GANG SURFACE MOUNT OUTLET BOXES UNLESS OTHERWISE NOTED. P. FOR AIL EMERGENCY ANn WAIL PHONE LOCATIONS THAT CALL FOR SURFACE RACEWAYS ASSUME SR -7 AND ASSOCIATED FITTINGS. Q. ALL EXISTING AND NEW PATHWAYS THAT ARE 2" AND LARGER, AND LONGER THAN 10' SHALL BE BONDED. R. ALL CABLE TRAYS SHALL BE ELECTRICALLY CONTINUOUS. COMMUNICATIONS PATHWAYS THAT END IN CLOSE PROXIMITY TO THE CABLE TRAY SHALL BE BONDED TO THE CABLE TRAY. S. ALL PATHWAYS TERMINATING IN THE MTR\ITR SHALL BE BONDED TO THE TMGB\TGB. T. CABLES SUPPORTED IN J HOOKS SHALL FOLLOW THE J HOOK MANUFACTURERS REQUIREMENTS FOR MOUNTING, SPACING, AND FILL CAPACITY. END OF NOTES ACCESS CONTROL SYMBOLS LEGEND Ei CARD READER LOCK El DOOR CONTACT (POSITION SWITCH) 0 SINGLE INPUT READER INTERFACE MODULE Di DUAL INPUT READER INTERFACE MODULE Plc INTELLIGENT SYSTEM CONTROLLER (CONTROL PANEL) PATHWAY SCHEDULE - NEW WORK CABLE FILL BASED ON CABLE OD d = 0.24 DESIGNATION DESCRIPTION MANUFACTURER PART NO. APPROXIMATE OUTSIDE DIMENSION APPROXIMATE INSIDE DIMENSION CABLE FILL CAPACITY* MIN. BEND RADIUS .75" C = CONDUIT SEE SPEC. SECTION 27 05 28 .75" DIA. 4 4.5" 1" C 1" DIA. 7 6" 1.25" C 1.25" DIA. 13 7.5" 1.5" C 1.5" DIA. 18 9" 2" C 2" DIA. 29 12" 2.5" C 2.5" DIA. 51 25" 3" C 3" DIA. 78 30" 4" C 4" DIA. 130 40" ETR SR -1 NOT USED ELEVATOR PHONE SR -2 ** SURFACE RACEWAY SEE SPEC. SECTION 27 05 28 2400 SERIES SEE SPEC. SECTION 27 05 28 12 GWB SR -3 ** SURFACE RACEWAY 3000 SERIES 32 SR -4 ** SURFACE RACEWAY 4000 SERIES 63 SR -4D ** SURFACE RACEWAY (DIVIDED) 4000D SERIES 30 SR -5 ** SURFACE RACEWAY 5400 SERIES 32 SR -6 ** SURFACE RACEWAY 6000 SERIES 140 SR -6D ** SURFACE RACEWAY (DIVIDED) 6000D SERIES 63 SR -7 SURFACE RACEWAY 700 SERIES 2 SINGLE -MODE OPTICAL FIBER CT -A TRAY NOT USED 2"x6" 106 TELECOMMUNICATION GROUND BUS BAR CT -B 2"x12" 211 CTC 2"x18" 316 CT -D 2"x24" 419 CT -E ETR 4"x12" 419 CT -F NOT USED 4"x18" 632 CT -G 4"x24" 844 CT -H 6"x12" 636 CT -I 12"x24" 1273 CT -.3 - - CT -K - - NOTES: o 40% MAXIMUM FILL FOR CATEGORY 6 INDICATED (PER TIA / EIA 569-A). - CAT6A CABLING HAS AN OD OF 0.285. - REDUCE FILL RATIO BY 6% FOR EACH 90° BEND - ENSURE THAT FILL RATIOS ARE NOT EXCEEDED 3/4" CONDUIT SHALL ONLY BE ALLOWED AS SPECIFICALLY NOTED ON DRAWINGS. ** REDUCE CAPACITY BY 50% FOR THE FOLLOWING CONDITIONS: - WHEN CONNECTORS ARE MOUNTED WITHIN RACEWAY - WHEN NON -RADIUS FITTINGS RESTRICT CROSS-SECTIONAL AREA - WHEN RACEWAY IS DIVIDED AND SHARED WITH ELECTRIC ALTER EXISTING SURFACE RACEWAY TO PROVIDE AT LEAST TWO 16" SECTIONS OF REMOVABLE COVERS TO ALLOW CABLE ROUGH -IN WITHOUT CONFLICT WITH EXISTING FURNITURE CONFIGURATIONS. ALSO REFER TO GENERAL NOTE "Z" ON T -GEN DRAWING FOR ADDITIONAL SCOPE FOR SURFACE RACEWAYS. WHERE REQUIRED BY RACEWAY CAPACITY, OR AS DIRECTED, PROVIDE SURFACE MOUNT EXTENSION BOX ON EXISTING RACEWAY OPENING TO PROVIDE ADEQUATE CAPACITY AND BEND RADIUS. ALSO REFER TO RACEWAY DERATING REQUIREMENTS AT LEFT. WHERE REQUIRED BY RACEWAY CAPACITY, OR AS DIRECTED, PROVIDE RETROFIT ENTRANCE END FI i i ING OR ALTER EXISTING BACKFED CONDUIT WITH A NEW SPACE SAVER CONNECTOR TO PROVIDE ADEQUATE CAPACITY AND BEND RADIUS FOR NEW CABLING. ALSO REFER TO RACEWAY DERATING REQUIREMENTS AT LEFT. FIELD VERIFY EXISTING CONDITIONS AND PROPOSE ALTERATIONS THAT MINIMIZE SERVICE DISRUPTION DURATION. PROVIDE ALL TEMPORARY PROVISIONS TO MAINTAIN EXISTING SERVICES. CONDUIT AND CABLE TRAY TO BE ROUTED CONCEALED UNLESS OTHERWISE NOTED. CEILING SCHEDULE OA SUSPENDED LAY -IN CEILING OB OPEN CEILING CO SPLINE CEILING OD SUSPENDED PLASTER CEILING OE SUSPENDED PLASTER CEILING O SUSPENDED GYPSUM CEILING ABBREVIATIONS ACM ASBESTOS CONTAMINATED MATERIAL AP ACCESS PANEL AHJ AUTHORITY HAVING JURISDICTION AWG AMERICAN WIRE GAUGE ARMM ARMORED RISER 24AWG MULTIPAIR CABLE BDF BUILDING DISTRIBUTION FRAME BICSI BUILDING INDUSTRY CONSULTING SERVICES INTERNATIONAL BSC BIO -SAFETY CABINET CCN CLOSED CIRCUIT TELEVISION CIT CORNELL INFORMATION TECHNOLOGIES CMP COMMUNICATIONS PLENUM RATED CABLE - NEC CMR COMMUNICATIONS RISER RATED CABLE - NEC CTR CIT SUPPORTED EQUIPMENT CABINET WITH ZONE CABLING DDC DIRECT DIGITAL CONTROL SYSTEM DEMARC VERIZON DEMARCATION POINT DN DOWN DOM DEPARTMENT OWNED AND MAINTAINED EF ENTRANCE FACILITY EH&S ENVIRONMENTAL HEALTH AND SAFETY EM EMERGENCY PHONE EMS ENERGY MANAGEMENT SYSTEM ERL "ERL" ADJACENT TO A DEVICE, FIXTURE OR PIECE OF EQUIPMENT INDICATES AN EXISTING ITEM TO BE RELOCATED. DISCONNECT AND REMOVE THE ITEM. REMOVE ALL UNNECESSARY RACEWAY AND WIRING. REINSTALL AND RECONNECT ITEM AS REQUIRED. MAINTAIN SERVICES AS CALLED FOR. ETR "ETR" ADJACENT TO A DEVICE, FIXTURE OR PIECE OF EQUIPMENT INDICATES AN EXISTING ITEM TO REMAIN. MAINTAIN EXISTING CONNECTIONS TO EQUIPMENT UNLESS OTHERWISE NOTED. EV ELEVATOR PHONE FACP FIRE ALARM CONTROL PANEL FO/OF FIBER OPTIC / OPTICAL FIBER FH FUME HOOD GWB GYPSUM WALL BOARD IEEE INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS ITR INTERMEDIATE TELECOMMUNICATIONS ROOM JB JUNCTION BOX LAN LOCAL AREA NETWORK LEC LOCAL EXCHANGE CARRIER / TELCO LS LIFE SAFETY MM MULTI -MODE OPTICAL FIBER MTR MAIN TELECOMMUNICATIONS ROOM OFNR OPTICAL FIBER NON-METALLIC STRENGTH RISER RATED OSHA OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION PB PULL BOX PP PATCH PANEL RAP REMOTE ANNUNCIATION PANEL SM SINGLE -MODE OPTICAL FIBER TC TELECOMMUNICATIONS CONTRACTOR TELCO PUBLIC TELEPHONE COMPANY (VERIZON) TGB TELECOMMUNICATION GROUND BUS BAR TMGB TELECOMMUNICATIONS MAIN GROUNDING BAR TIA TELECOMMUNICATION INDUSTRY ASSOCIATION TR TELECOMMUNICATIONS ROOM TYP TYPICAL UNO UNLESS NOTED OTHERWISE UPS UNINTERRUPTIBLE POWER SUPPLY UTP UNSHIELDED TWISTED PAIR VIF VERIFY IN FIELD VOM VERIZON OWNED AND MAINTAINED WAP WIRELESS ACCESS POINT TELECOM SYMBOLS LEGEND (REV. 02/12) DEMO EXISTING NEW DESCRIPTION Q N IA I Q TELECOM OUTLET - FLOOR BOX 'c:7: 0 `d TELECOM OUTLET - CEILING MOUNTED <1 <-1 4 . j TELECOM OUTLET - WALL MOUNTED CONDUITS SIZE AS INDICATED - —u— —J— J -HOOKS - WHERE INDICATED CONDUIT WITH BUSHINGS - TYPE & SIZE AS ] [ i . INDICATED PULLBOX: X = SIZE: Cornell University PROJECT PB—X PB x NETWORK Pe x (S) SMALL, (M) MEDIUM, (L) LARGE LxWxH LxWxH LxWxH LxWxH = DIMENSIONS IN INCHES CTR CTR FR EQUIPMENT CABINET WITH ZONE CABLING LPJ AP Vk2 ACCESS PANEL - CEILING MOUNT NSR-, ®SR-# EJSR-# VERTICAL RACEWAY - DOWN (SR -2 UNO) HSR eSR-# HsR-# VERTICAL RACEWAY - UP (SR -2 UNO) Max CT -X 4crx VERTICAL CABLE TRAY - DOWN HCT-X ICT -x HGT x VERTICAL CABLE TRAY - UP • • • CONDUIT/SLEEVE - UP , a 0 CONDUIT/SLEEVE - DOWN ,i © D CONDUIT/SLEEVE - THRU (BETWEEN FLOORS) HORIZONTAL RACEWAY - SIZED PER PATHWAY E.�;a� SR-# ! SCHEDULE 09/30/11 HORIZONTAL CABLE TRAY - SIZED PER CT -X I CT -x CT -X 09/07/11 PATHWAY SCHEDULE MARK IIII 1111 ■■■ CABLE RUNWAY X 0 $ 0 SPLICE CASE ® P ® COMMUNICATIONS POWER POLE imomiiiim SERVING ZONE OR MTR/ITR BOUNDARY AT PROJECT NO: 11103-2047A CTR SERVING ZONE BOUNDARY OWNER PROJECT NO: 754 NEW / EXISTING OUTLET SUBSCRIPT KEY (REFER TO ADDITIONAL DESCRIPTORS THIS DRAWING) 4xz?A "A" ROOM LOCATION CODE "#" EXISTING OUTLET NOTE "xx" EXISTING PATHWAY TYPE TO BE REUSED "yy" OUTLET DESCRIPTOR "zz" NEW PATHWAY TYPE YY® YY NEW PATHWAY TYPE KEY CC CONDUIT TO CEILING CF CONDUIT TO FLOOR CL CONDUIT TO CLOSET CI CONDUIT HOMERUN TO ITR/MTR CP CONDUIT TO PULLBOX CT CONDUIT TO CABLE TRAY FW FISHABLE WALL JP J -HOOK TO PULLBOX JS J -HOOK TO SLEEVE JT J -HOOK TO CABLE TRAY PT PULLBOX TO CABLE TRAY SC SURFACE RACEWAY TO CEILING SF SURFACE RACEWAY TO FLOOR SH SURFACE RACEWAY TO HALL (RACEWAY THROUGH ROOM TO HALLWAY PRIMARY HORIZONTAL PATHWAY) SW SURFACE THROUGH WALL DOB NEW DEVICE OPENING IN EXISTING SURFACE RACEWAY, WITH BLANK PLATE (MATCH EXISTING COLOR) NOTE: PROVIDE MINIMUM 1" CONDUIT UNLESS NOTED OTHERWISE. INCREASE SIZE AS REQUIRED PER CABLE FILL CHART. NOTE: PROVIDE MINIMUM SIZE METALLIC RACEWAY BASED ON CABLE FILL CHART UNLESS NOTED OTHERWISE. NOTE: ASSUME PATHWAY TYPE "CP" UNLESS NOTED OTHERWISE. OUTLET DESCRIPTOR KEY ##" HEIGHT ABOVE FINISHED FLOOR (AFF) - EXAMPLE: 48" BAC BUILDING ACCESS CONTROLLER EM EMERGENCY TELEPHONE OUTLET EV ELEVATOR TELEPHONE LINE CONNECTION EMS ENERGY MANAGEMENT FACP FIRE ALARM CONTROL PANEL P WALL MOUNTED PAY -PHONE OUTLET W WALL MOUNTED TELEPHONE OUTLET TO BE MOUNTED AT 48" AFF WAP WIRELESS ACCESS POINT - REFER TO DETAIL AT -27052839. EXISTING OUTLET NOTE KEY A EXISTING DEVICE OR OPENING WITH LEGACY CABLING. REMOVE CABLING, PAINT/PATCH OR PROVIDE BLANK AS APPLICABLE. EXISTING ONE -GANG BOX AND PATHWAYS TO BE REUSED AS L\ INDICATED. MAINTAIN EXISTING SERVICES UNTIL AFTER CUTOVER, THEN REMOVE CABLING. EXISTING TWO -GANG BOX AND PATHWAYS TO BE REUSED AS /z\ INDICATED. MAINTAIN EXISTING SERVICES UNTIL AFTER CUTOVER, THEN REMOVE CABLING. E: 'STING OUTLET LOCATION IN SURFACE RACEWAY. PATHWAYS TO BE REUSED AS INDICATED. MAINTAIN ANY EXISTING SERVICE UNTIL A\ AFTER CUTOVER, THEN REMOVE CABLING. PROVIDE DEVICE BRACKETS AS REQUIRED. EXISTING PATHWAYS, BOXES, RACEWAYS AND CAT.5, CAT.5E OR CAT.6 CABLES TO REMAIN. EXISTING PATHWAYS, BOXES AND RACEWAYS TO REMAIN. COORDINATE SHUTDOWN AND CONDUIT/CABLE REWORK TO RELOCATE FROM EXISTING TR TO NEW TR PER T1 -PL, T1 -SZ AND APPENDIX A. REASSIGN CABLE PANEL/PORTS AS CALLED FOR. CABLING SYMBOLS LEGEND 2B -101-A1 CABLE IDENTIFICATION LABEL: 2B COMMUNICATIONS EQUIPMENT ROOM 101 MASTER LOCATION CODE A ROOM LOCATION CODE 1 POSITION i J:\PROJECTS-Ithaca\2011\ 11103 CORNELL - NCP\Kroch Library 2047A\CAD\ 1 1 103-2047A--T-GEN.dwc SCALES ON THIS DRAWING ACCURATE WHEN PLOTTED TO: ARCH El (30X42 IN.) 971 lip eamA 115 METRO PHONE: ARCH1TECHNOLOGY, LLC www.archi-technology.com PARK ROCHESTER, NY 14623 585.424.1952 Fax: 585.424.4239 r Q N tz 4q..0 N 1 Q oC CO >-- Z I Q U a II f uJ F�--i Z uJ zU 0 U c F---� CLIENT: Cornell University PROJECT 4 CONNECTIVITY NETWORK - CD 06/29/12 CONSTRUCTION DOCUMENTS 100 DD 05/11/12 100% DD SUBMISSION 50 DD 04/06/12 50% DD SUBMISSION 20 SD 09/30/11 20% SD SUBMISSION PSD 09/07/11 PRELIMINARY SD SUBMISSION MARK DATE DESCRIPTION CONSTRUCTION DOCUMENTS ISSUE DATE: 06/29/12 r a AT PROJECT NO: 11103-2047A OWNER PROJECT NO: 754 DRAWN BY: LP/EL/PKB CHECKED BY: JLB PROJECT MANAGER: GHS SHEET TITLE: STANDARD SYMBOLS NOTES, ABBREVIATIONS (T -SERIES)