HomeMy WebLinkAboutPages from 031815 CLARA DICKSON CONFORMED SET2. PIPING SHOWN ON DRAWINGS HAS BEEN DEVELOPED FROM
PROJECT RECORD DRAWINGS AND FIELD VERIFIED TO THE
GREATEST EXTENT POSSIBLE. CONTRACTOR SHALL VERIFY IN FIELD
ALL LOCATIONS PRIOR TO REMOVAL OF WALLS AND SAW CUTTING
OF FLOC)
PI' OUTING WAS DEVELOPED FROM AS BUILDS DRAWINGS AND WAS
FURTHER INSPECTED WITH TV AND PREVIOUSLY EXCAVATED AT THREE
LOCATIONS. CONTRACTOR MAY ASSUME PIPING ROUTING SHOWN IS
ACCURATE.
3. REMOVE, STORE AND REINSTALL PLUMBING FIXTURES AS NOTED
ON DRAWINGS.
4. CONTRACTOR SHALL REMOVE GWB, PLASTER AND CONCRETE
BLOCK WALLS AS SHOWN ON DRAWINGS TO FACILITATE PIPE
REPLACEMENT.
5. CONTRACTORS SHALL BE RESPONSIBLE TO PROTECT
ABOVE—GROUND PIPING SYSTEMS AND SURROUNDING BUILDING
SURFACES I.E. FLOORS, WALLS, ETC. CONTRACTOR SHALL
REPLACE ANY PIPE INSULATION, ABOVE GROUND PIPE, AND REPAIR
ANY SURFACES DAMAGED IN THE PERFORMANCE OF THIS PROJECT.
6. FOR BASIS OF BIDDING, ASSUME FLOOR SAW CUTS WILL NOT
ENCOUNTER ANY IN SLAB CONDUITS.
7. LOCATION OF DUMPSTER SHALL BE ADJACENT TO COLUMN LINE
69 AND MINIMUM 10 FEET FROM BUILDING. LOCATION SHALL BE
COORDINATED WITH CORNELL PROJECT MANAGER. DUMPSTER
SHALL BE SCREENED FROM VIEW ON THE ROAD SIDE WITH 6'
HIGH PEDESTAL METAL FENCING WITH GREEN SIGHT COVERS.
ANCHOR FENCING TO MINIMIZE OVERTURNING DUE TO WIND.
N:\915706\Conformed Drawings\P100 YR 1 Conformed.dwg, 3/18/2015 3:30:18 PM, N81
ADD #1
1\ADD #1
SINGLE
ROOM
CLOSET
2" VENT
UP
3" UP
TO FD
116371
BATHROOM
2" SAN UP
TO LAVS
16211
SINGLE
ROOM
1063
DATA
SINGLE
ROOM
3" SAN UP
TO WC
11643 I
SINGLE
ROOM
REMOVE
PORTION
OF WIRE
LATH
AND
PLASTER
WALL.
2" SAN UP
TO SH
(TYP 2�,
■' REMOVE C.I. SAN
MIN. 6" ABOVE FLOOR
SLAB. (TYP)
(1635
SINGLE
ROOM
4" UP
631B)
SINGLE
ROOM
116311
SINGLE
ROOM
(2629B)
11627
SINGLE SINGLE
ROOM ROOM
REMOVE PORTION
OF WIRE LATH AND
PLASTER WALL
116251
SINGLE
ROOM
SINGLE
ROOM
1621A
CLOSET
" UP (2625B)
162301
CLOSET
EXISTING HUB
DRAIN TO
REMAIN
LIGHT BULB
ROOM
1635A1
CLOSET
163101
CLOSET
1629A
CLOSET
162701
CLOSET
1625A
SINK
ROOM
CLOSET
T
B.O.P. 25"±
BELOW SLAB
---- 4; -- -- 1031
— SAN
C±DRRIOOR-
4"
(E) SAN
B.O.P. 15"±
BELOW SLAB
(E)FC0
UP
1005
STAIR
CO \
4" UP
_622 STACK
116191
BIKE
STORAGE
3" UP
116221
MCLLU
DEN
EXIST NG PIPE
—TO REMAIN
(2630B)
SAWCUT FLOOR REFER TO
REMOVAL NOTE 1 (TYP.)
11618
STORAGE
OWNER WILL RELOCATE EQUIPMENT
AWAY FROM WORK AREA.
0
116191
STORAGE
116451
DOUBLE
ROOM
110091
STAIR
KITCHEN
1
of
REMOVAL NOTES:
1. IN AREAS SHOWN, SAWCUT FLOOR, REMOVE CONCRETE SLAB AND
HAND EXCAVATE AROUND SANITARY LINE. REMOVE PIPE AS
INDICATED ON DRAWINGS. REMOVE RISERS MINIMUM OF 6"
ABOVE FLOOR SLAB.
\ADD #1
414)
A\ADD #1
11675
SINGLE
ROOM
1673 I
SINGLE
ROOM
116711
SINGLE
ROOM
16691
SINGLE
ROOM
116671
SINGLE
ROOM
4" UP (2
(2670) _
116651
SINGLE SINGLE
ROOM ROOM
REMOVE PORTION OF WIRE LATH
AND PLASTER WALL.
116611
SINGLE
ROOM
116591
SINGLE
ROOM
11648
EXISTING PIPE STORAGE
TO I REMAIN
MAINTENANCE
1675A
CLOSET
CLOSET
CLOSET
1669AI
CLOSET
166301
CLOSET
CLOSET
EXISTING PIPE
TO REMAIN
116151
RECREATION
ROOM
CORRIDOR
4" UP
(2636A)
EMOVE UTILITY
SINK, STORE FOR
REINSTALLATION
J I VISFI�C
REMOVE PORTIONI OF WIRE
LATH AND PLASTER WALL
11662
EXIST
B.O.P. 31" ±
BELOW SLAB
SUMP PIT
WITH PUMP
USE CARE TO AVOID DAMAGING
PAVEMENTS, TREES AND BUILDING
FINISHES. CONTRACTOR SHALL BE
RESPONSIBLE FOR RESTORATION OF
DAMAGED AREAS. IF PROPER CARE IS
EMPLOYED, RESTORATION MAY BE
LIMITED TO TOPSOIL AND SEED.
11674
DOUBLE
ROOM
1-1/2" SAN
UP TO LAV
(1679)
2"VENT UP
(TO REMPIN)
116501
\EXISTING 2"PUMP
DISCHARGE UP
(TO REMAIN)
3" UP TO FD
(TO REMAIN)
MECHANICAL
ROOM
REMOVE AND REPLACE
FLOOR DRAIN AT
BOTTOM OF SUMP
2" TO SH
(TYP)
EXISTING SUMP
TO REMAIN
3" SAN UP TO
WC (TYP 3)
1-1/2" SAN UP
TO LAVS (1679)
115391
STORAGE
REMOVE PORTION OF
WIRE LATH AND
PLASTER WALL
EXIST. STORM
MANHOLE
HADD #1 EXIST. SANITARY
MANHOLE
PULL 6" EXISTING PIPE OUT OF
EXISTING MANHOLE. INSERT MAIN PIPE
AND REPAIR OPENING AND BENCH
WALLS WITH NON—SHRINK GROUT.
REMOVE HOUSE TRAP,
CLEANOUT & FRESH
AIR INLET
LOCKER ROOM
REMOVE CERAMIC
TILE WALL FOR
ACCESS TO WATER
PIPING
EXIST
B.O.P. 45.5" ±
BELOW B
CAREFULLY REMOVE
TILE SHOWER FLOORS.
REPAIR SCHLUTER
WATERPROOF SYSTEM.
COORDINATE WORK W/EXISTING
ELECTRIC/DATA OUTLETS
REMOVE DRAINS,
AND PIPING
SERVING SHOWERS
IN ROOM 1538
ADD #1
6 SIDE (NORTH) ,
5 SIDE (SOUTH)
OWNER WILL RELOCATE RESTROOM
LOCKERS OUT OF WORK AREA.
INVERT ELEVATION TO MATCH
EXISTING. ASSUME 48" BELOW
FINISHED FLOOR.
BREAK
—ReeM— — — —
1
2"ST UP
11535
PROJECT
ROOM
110271
CORRIDOR
SPRINKLER
ROOM
MECHANICAL
ROOM
FCO
SERVICE
ELEVATOR
000F
HYDRAULIC
ELEVATOR
(44
"S RISER
110281
RECEIVING
5"ST RISER
10280
— 51
SAWCUTFLOOR REFER TO
REMOVAL NOTE 1 (TYP.)
YEAR 1 WORK
YEAR 2 WORK
6 SIDE (NORTH)
5 SIDE (SOUTH)
UNDERFLOOR PIPING REMOVAL PLAN - NORTH
SCALE: 1/8" = 1'-0
1 /8" =
1 0 1
3
5
*I/
NOTE
YEAR 2 WORK IS SHOWN FOR REFERENCE PURPOSES ONLY, AND IS
NOT INCLUDED IN THE CURRENT SCOPE OF WORK.
9 11 13 15
I MI MN N
I■ NI MI =
6 SIDE NORTH
5 SIDE SOUTH
CONFORM TO INDICATED DIMENSIONS RATHER THAN DIMENSIONS SCALED FROM
DRAWING. GRAPHIC SCALE PROVIDED HEREIN FOR GENERAL INFORMATION AND TO
CONFIRM WHEN DRAWING SIZE HAS BEEN REDUCED OR INCREASED IN REPRODUCTION.
g
THIS STATEMENT IS PROVIDED HEREIN AS REQUIRED BY
FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ENGINEER TO ALTER THIS DOCUMENT IN ANY WAY
g
IT IS A VIOLATION OF THE
0 0
- a
0
c.
Ala
�
a)
W
c
0 •-
L.
v/
.1c
CD
O. V
7.7
* >/
7
7
.,
0
3/18/15
Drawn
K.A. SNYDER H. JUNUZOVIC
Designed
K.A. SNYDER
Checked
P.A. PETERSON
Revision
CONFORMED DRAWINGS
d
Cz
Project/Sheet Title
1
Scale
AS SHOWN
Date
12/31/14
Drawn
K.A. SNYDER H. JUNUZOVIC
Designed
K.A. SNYDER
Checked
P.A. PETERSON
Project No. C14151
Drawing No.
P100
YEAR1&2
Sheet No. 2 of 7