HomeMy WebLinkAboutPages from 031815 CLARA DICKSON CONFORMED SET2. PIPING SHOWN ON DRAWINGS HAS BEEN DEVELOPED FROM PROJECT RECORD DRAWINGS AND FIELD VERIFIED TO THE GREATEST EXTENT POSSIBLE. CONTRACTOR SHALL VERIFY IN FIELD ALL LOCATIONS PRIOR TO REMOVAL OF WALLS AND SAW CUTTING OF FLOC) PI' OUTING WAS DEVELOPED FROM AS BUILDS DRAWINGS AND WAS FURTHER INSPECTED WITH TV AND PREVIOUSLY EXCAVATED AT THREE LOCATIONS. CONTRACTOR MAY ASSUME PIPING ROUTING SHOWN IS ACCURATE. 3. REMOVE, STORE AND REINSTALL PLUMBING FIXTURES AS NOTED ON DRAWINGS. 4. CONTRACTOR SHALL REMOVE GWB, PLASTER AND CONCRETE BLOCK WALLS AS SHOWN ON DRAWINGS TO FACILITATE PIPE REPLACEMENT. 5. CONTRACTORS SHALL BE RESPONSIBLE TO PROTECT ABOVE—GROUND PIPING SYSTEMS AND SURROUNDING BUILDING SURFACES I.E. FLOORS, WALLS, ETC. CONTRACTOR SHALL REPLACE ANY PIPE INSULATION, ABOVE GROUND PIPE, AND REPAIR ANY SURFACES DAMAGED IN THE PERFORMANCE OF THIS PROJECT. 6. FOR BASIS OF BIDDING, ASSUME FLOOR SAW CUTS WILL NOT ENCOUNTER ANY IN SLAB CONDUITS. 7. LOCATION OF DUMPSTER SHALL BE ADJACENT TO COLUMN LINE 69 AND MINIMUM 10 FEET FROM BUILDING. LOCATION SHALL BE COORDINATED WITH CORNELL PROJECT MANAGER. DUMPSTER SHALL BE SCREENED FROM VIEW ON THE ROAD SIDE WITH 6' HIGH PEDESTAL METAL FENCING WITH GREEN SIGHT COVERS. ANCHOR FENCING TO MINIMIZE OVERTURNING DUE TO WIND. N:\915706\Conformed Drawings\P100 YR 1 Conformed.dwg, 3/18/2015 3:30:18 PM, N81 ADD #1 1\ADD #1 SINGLE ROOM CLOSET 2" VENT UP 3" UP TO FD 116371 BATHROOM 2" SAN UP TO LAVS 16211 SINGLE ROOM 1063 DATA SINGLE ROOM 3" SAN UP TO WC 11643 I SINGLE ROOM REMOVE PORTION OF WIRE LATH AND PLASTER WALL. 2" SAN UP TO SH (TYP 2�, ■' REMOVE C.I. SAN MIN. 6" ABOVE FLOOR SLAB. (TYP) (1635 SINGLE ROOM 4" UP 631B) SINGLE ROOM 116311 SINGLE ROOM (2629B) 11627 SINGLE SINGLE ROOM ROOM REMOVE PORTION OF WIRE LATH AND PLASTER WALL 116251 SINGLE ROOM SINGLE ROOM 1621A CLOSET " UP (2625B) 162301 CLOSET EXISTING HUB DRAIN TO REMAIN LIGHT BULB ROOM 1635A1 CLOSET 163101 CLOSET 1629A CLOSET 162701 CLOSET 1625A SINK ROOM CLOSET T B.O.P. 25"± BELOW SLAB ---- 4; -- -- 1031 — SAN C±DRRIOOR- 4" (E) SAN B.O.P. 15"± BELOW SLAB (E)FC0 UP 1005 STAIR CO \ 4" UP _622 STACK 116191 BIKE STORAGE 3" UP 116221 MCLLU DEN EXIST NG PIPE —TO REMAIN (2630B) SAWCUT FLOOR REFER TO REMOVAL NOTE 1 (TYP.) 11618 STORAGE OWNER WILL RELOCATE EQUIPMENT AWAY FROM WORK AREA. 0 116191 STORAGE 116451 DOUBLE ROOM 110091 STAIR KITCHEN 1 of REMOVAL NOTES: 1. IN AREAS SHOWN, SAWCUT FLOOR, REMOVE CONCRETE SLAB AND HAND EXCAVATE AROUND SANITARY LINE. REMOVE PIPE AS INDICATED ON DRAWINGS. REMOVE RISERS MINIMUM OF 6" ABOVE FLOOR SLAB. \ADD #1 414) A\ADD #1 11675 SINGLE ROOM 1673 I SINGLE ROOM 116711 SINGLE ROOM 16691 SINGLE ROOM 116671 SINGLE ROOM 4" UP (2 (2670) _ 116651 SINGLE SINGLE ROOM ROOM REMOVE PORTION OF WIRE LATH AND PLASTER WALL. 116611 SINGLE ROOM 116591 SINGLE ROOM 11648 EXISTING PIPE STORAGE TO I REMAIN MAINTENANCE 1675A CLOSET CLOSET CLOSET 1669AI CLOSET 166301 CLOSET CLOSET EXISTING PIPE TO REMAIN 116151 RECREATION ROOM CORRIDOR 4" UP (2636A) EMOVE UTILITY SINK, STORE FOR REINSTALLATION J I VISFI�C REMOVE PORTIONI OF WIRE LATH AND PLASTER WALL 11662 EXIST B.O.P. 31" ± BELOW SLAB SUMP PIT WITH PUMP USE CARE TO AVOID DAMAGING PAVEMENTS, TREES AND BUILDING FINISHES. CONTRACTOR SHALL BE RESPONSIBLE FOR RESTORATION OF DAMAGED AREAS. IF PROPER CARE IS EMPLOYED, RESTORATION MAY BE LIMITED TO TOPSOIL AND SEED. 11674 DOUBLE ROOM 1-1/2" SAN UP TO LAV (1679) 2"VENT UP (TO REMPIN) 116501 \EXISTING 2"PUMP DISCHARGE UP (TO REMAIN) 3" UP TO FD (TO REMAIN) MECHANICAL ROOM REMOVE AND REPLACE FLOOR DRAIN AT BOTTOM OF SUMP 2" TO SH (TYP) EXISTING SUMP TO REMAIN 3" SAN UP TO WC (TYP 3) 1-1/2" SAN UP TO LAVS (1679) 115391 STORAGE REMOVE PORTION OF WIRE LATH AND PLASTER WALL EXIST. STORM MANHOLE HADD #1 EXIST. SANITARY MANHOLE PULL 6" EXISTING PIPE OUT OF EXISTING MANHOLE. INSERT MAIN PIPE AND REPAIR OPENING AND BENCH WALLS WITH NON—SHRINK GROUT. REMOVE HOUSE TRAP, CLEANOUT & FRESH AIR INLET LOCKER ROOM REMOVE CERAMIC TILE WALL FOR ACCESS TO WATER PIPING EXIST B.O.P. 45.5" ± BELOW B CAREFULLY REMOVE TILE SHOWER FLOORS. REPAIR SCHLUTER WATERPROOF SYSTEM. COORDINATE WORK W/EXISTING ELECTRIC/DATA OUTLETS REMOVE DRAINS, AND PIPING SERVING SHOWERS IN ROOM 1538 ADD #1 6 SIDE (NORTH) , 5 SIDE (SOUTH) OWNER WILL RELOCATE RESTROOM LOCKERS OUT OF WORK AREA. INVERT ELEVATION TO MATCH EXISTING. ASSUME 48" BELOW FINISHED FLOOR. BREAK —ReeM— — — — 1 2"ST UP 11535 PROJECT ROOM 110271 CORRIDOR SPRINKLER ROOM MECHANICAL ROOM FCO SERVICE ELEVATOR 000F HYDRAULIC ELEVATOR (44 "S RISER 110281 RECEIVING 5"ST RISER 10280 — 51 SAWCUTFLOOR REFER TO REMOVAL NOTE 1 (TYP.) YEAR 1 WORK YEAR 2 WORK 6 SIDE (NORTH) 5 SIDE (SOUTH) UNDERFLOOR PIPING REMOVAL PLAN - NORTH SCALE: 1/8" = 1'-0 1 /8" = 1 0 1 3 5 *I/ NOTE YEAR 2 WORK IS SHOWN FOR REFERENCE PURPOSES ONLY, AND IS NOT INCLUDED IN THE CURRENT SCOPE OF WORK. 9 11 13 15 I MI MN N I■ NI MI = 6 SIDE NORTH 5 SIDE SOUTH CONFORM TO INDICATED DIMENSIONS RATHER THAN DIMENSIONS SCALED FROM DRAWING. GRAPHIC SCALE PROVIDED HEREIN FOR GENERAL INFORMATION AND TO CONFIRM WHEN DRAWING SIZE HAS BEEN REDUCED OR INCREASED IN REPRODUCTION. g THIS STATEMENT IS PROVIDED HEREIN AS REQUIRED BY FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ENGINEER TO ALTER THIS DOCUMENT IN ANY WAY g IT IS A VIOLATION OF THE 0 0 - a 0 c. Ala � a) W c 0 •- L. v/ .1c CD O. V 7.7 * >/ 7 7 ., 0 3/18/15 Drawn K.A. SNYDER H. JUNUZOVIC Designed K.A. SNYDER Checked P.A. PETERSON Revision CONFORMED DRAWINGS d Cz Project/Sheet Title 1 Scale AS SHOWN Date 12/31/14 Drawn K.A. SNYDER H. JUNUZOVIC Designed K.A. SNYDER Checked P.A. PETERSON Project No. C14151 Drawing No. P100 YEAR1&2 Sheet No. 2 of 7