HomeMy WebLinkAboutClara Dickson - Sanitary Line ReplacementSECTION 09 30 00 - TILE
PRODUCTS
SECTION INCLUDES
Tile and Accessories:
Preparation of substrates
Ceramic mosaic flooring
RELATED SECTIONS
REFERENCES
American National Standards Institute (ANSI):
ANSI A108/A118/A136.1 - Specifications for the Installation of Ceramic Tile.
ANSI A137.1 - Specifications for Ceramic Tile.
American International (ASTM):
ASTM C 144 - Standard Specification for Aggregate for Masonry Mortar.
ASTM C 150 - Standard Specification for Portland Cement.
ASTM C 207 - Standard Specification for Hydrated Lime for Masonry Purposes.
ASTM C 1028 - Standard Test Method for Determining the Static Coefficient of Friction or Ceramic Tile and Other Like Surfaces by the Horizontal Dynamometer Pull-Meter Method.
ASTM D 4397 - Specification for Polyethylene Sheeting for Construction, Industrial, and Agricultural Applications.
Tile Council of North America (TCNA): TCA Handbook for Ceramic Tile Installation, 2007.
PERFORMANCE REQUIREMENTS
Static Coefficient of Friction: Tile on walkway surfaces shall meet or exceed the following values as determined by testing in conformance with ASTM C 1028.
Level Surfaces: Minimum of 0.6 (Wet).
SUBMITTALS
Submit under provisions of Section 01 33 00. Obtain approvals of submittals prior to delivering products to the jobsite.
Product Data: Manufacturer's data sheets on each product to be used, including:
Preparation instructions and recommendations.
Storage and handling requirements and recommendations.
Installation methods.
Shop Drawings: Indicate tile layout, patterns, color arrangement, perimeter conditions, junctions with dissimilar materials, control and expansion joints, thresholds, ceramic accessories,
and setting details.
Selection Samples: Color charts illustrating full range of colors and patterns.
Selection Samples: Full-size samples of actual tiles for selection.
Verification Samples: For tile 8 by 8 inches (203 by 203 mm) and smaller, mount actual units on minimum 12 by 12 inch (305 by 305 mm) plywood panels and grout with selected grout. For
larger tile, submit two units of each type, and grout chart indicating selections.
Manufacturer's Certificate: When applicable, submit a Master Grade Certificate signed by the manufacturer and the installer certifying that products meet or exceed the specified requirements
of ANSI A137.1.
Maintenance Data: Include recommended cleaning methods, cleaning materials, and maintenance coatings.
QUALITY ASSURANCE
Installer Qualifications: Company specializing in performing the work of this section with minimum two years experience.
Single Source Responsibility: Obtain each type and color of tile from a single source. Obtain each type and color of mortar, adhesive and grout from the same source.
General: Provide tile that complies with ANSI A137.1 where applicable for types, compositions and other characteristics indicated. Provide tile in the locations and of the types colors
and pattern indicated on the Drawings.
Factory Blending: For tile exhibiting color variations within the ranges selected under Submittal of samples, blend tile in the factory and package so tile taken from one package shows
the same range of colors as those taken from other packages.
Mounting: For factory mounted tile, provide back or edge mounted tile assemblies as standard with the manufacturer, unless otherwise specified.
Factory Applied Temporary Protective Coatings: Where indicated under tile type, protect exposed surfaces of tile against adherence of mortar and grout by precoating with a continuous
film of petroleum paraffin wax applied hot. Do not coat unexposed tile surfaces.
DELIVERY, STORAGE, AND HANDLING
Deliver and store products in manufacturer's unopened packaging until ready for installation.
Protect setting materials from freezing or overheating in accordance with manufacturer's instructions.
Store tile and setting materials on elevated platforms, under cover and in a dry location and protect from contamination, dampness, freezing or overheating.
ENVIRONMENTAL REQUIREMENTS
Do not install adhesives in an unventilated environment.
Maintain ambient and substrate temperature of 50 degrees F (10 degrees C) during tiling and for a minimum of 7 days after completion.
EXTRA MATERlALS
Provide for Owner's use a minimum of 2 percent of the primary sizes and colors of tile specified, boxed and clearly labeled.
PRODUCTS
MANUFACTURERS
Acceptable Manufacturer: American Olean Tile Co., which is located at: 7834 C. F. Hawn Fwy. P. O. Box 17130 ; Dallas, TX 75217; Toll Free Tel: 888-AOT TILE; Tel: 214-398-1411; Fax: 215-822-1353;
Web:www.americanolean.com
Requests for substitutions will be considered in accordance with provisions of Section
01 25 00.
TILE
Glazed Porcelain:
Series: Belmar.
Floor Field Tile Size: 2 by 2 inches.
Series: Bevalo.
Moisture Absorption: Less than 3 percent.
Trim Name: Bullnose, Surface Bullnose, Surface Bullnose Outcorner, Radius Bullnose, Radius Bullnose Outcorner, Mosaic Bullnose, Corner Rail, Corner Rail Outcorner, Quarter Round, Quarter
Round Corner.
EXECUTION
EXAMINATION
Acceptability of Surfaces: Inspect surfaces to be tiled to ensure proper bonding can be achieved, and to verify that surfaces are free of curing membranes, oil, grease, wax and dust.
Substrate Tolerances: Before tiling, inspect surfaces to be tiled to verify that the following tolerances are not exceeded. If tolerances are exceeded, provide specified leveling coat
to achieve specified tolerances.
Walls: 1/8 inch in 8 feet (3 mm in 2.4 m) for dry-set mortar, epoxy and organic adhesives.
Floors: 1/8 inch in 10 feet (3 mm in 3 m) for dry-set mortar and epoxy; 1/16 inch in 3 feet (1.5 mm in 1 m) for organic adhesive.
PREPARATION
Layout: Determine locations of control and expansion joints before starting tile work. Layout tile work to minimize cuts less than one-half tile in size.
CLEANING AND PROTECTION
Cleaning: Clean tile within time period recommended by manufacturer, using materials recommended by manufacturer.
Protection: Prohibit foot and wheeled traffic from floors for a minimum of 3 days. Where traffic is unavoidable, provide large flat boards in walkways and wheelways for a minimum of
7 days after installation. Protect from construction dirt and debris with heavy-duty, non-
staining construction paper, masked in place.
END OF SECTION