Loading...
HomeMy WebLinkAboutAddenda_Standard FormattingCORNELL UNIVERSITY CHI PHI FRATERNITY FACILITIES CONTRACTS INTERIOR FINISHES RESTORATION 121 HUMPHREYS SERVICE BUILDING ITHACA, NEW YORK 14853-3701 ADDENDUM NO. 1 September 3, 2014 This Addendum contains changes to the requirements of the Contract Documents and Specifications. Such changes are to be incorporated into the Construction Documents and shall apply to the work with the same meaning and force as if they had been included in the original document. Wherever this Addendum modifies a portion of a paragraph of the specifications or a portion of any Drawing, the remainder of the Paragraph or Drawing shall remain in force. NOTE: Provisions of all Contract Documents apply. SAMPLES FOR TABLE OF CONTENTS, INSTRUCTIONS TO BIDDERS, AND BID FORM ITEMS Table of Contents REPLACE Page 2 in its entirety with attached. SAMPLES FOR GENERAL REQUIREMENT ITEMS Section 01 23 00 Alternates: Part 1.3, SCHEDULE OF ALTERNATES ADD Item E ALTERNATE NO. FR1 (ADD) Installation of Lightning Protection. See Technical Specification Section 26 4113 Lightning Protection for Structures and Sketches SK1, SK2 and SK3 for additional information. Section 01 50 00, Temporary Facilities and Controls; Section 2.8A,. Guardrails and Barricades, 2.8, A ADD Item 2. 2. Provide construction fence consistent of 6 foot chain link fence with a green mesh privacy screen. The Privacy screen is to be attached using metal ties. The fence is to be supported by 2” diameter pipes driven 2’ to the ground. Underground Utilities must be marked prior to installation. SAMPLES FOR TECHNICAL SPECIFICATION ITEMS Section 04 01 20, Paragraph 2.3.A.1 ADD the following subparagraphs : Basis of Design: Portage sandstone (bluestone), in a yellow-green color Compressive Strength, Wet-Parallel (ASTM C170): min. 8000 psi Compressive Strength, Wet- Perpendicular (ASTM C170): min. 6200 psi Absorption (ASTM C97): max. 1.5% Pre-qualified stone supplier: Tompkins Bluestone Company, Inc. Hancock, NY 13783 Tel: 607.637.5222 Section 23 82 16, Part 2, Paragraph 2.2, Item F: DELETE “Fins: Copper, minimum 0.006 inch thick” REPLACE with ”Fins: Aluminum, .5 inch high” Section 08 63 00, Paragraph 1.9 ADD the following New paragraph: B. Note that for bidding purposes, the dimensions of the new skylight shall be based on Detail 6/R1.1 rather than Detail 1/R1 or Detail 2/R2. Monitor over-framing will effectively increase the overall length and width of the skylight approximately 8-1/2”. SAMPLES FOR DRAWINGS ITEMS Drawing AD-101 DELETE Drawings S-102 and S-500 REPLACE with revised Drawings S-102 and S-500 Drawing A-000 DELETE Structural Steel General Note 3.0 in its entirety. REPLACE with “Welded connections shall be made by an approved certified welder using filler metal conforming to E70XX (AISC Permissible Stress of 21KSI). Provide end returns of fillet welds unless noted. Drawing A-201, Detail 3: ADD The following note: “Provide No. 1 hand compacted crushed stone” INCLUDE RFI LOG RFI Questions and Clarifications See attached RFI Log (Items 1 - 8) Attachments: Revised drawings S-102 and S-500 Attendees at pre-bid walk-through meeting ****END OF ADDENDUM****