HomeMy WebLinkAboutBaker LabDRAWING STATUSISSUED FOR: BID DOCUMENTSDATE: JUNE 23, 2014259 EAST AVENUEITHACA, NEW YORK 14850LABELLA PROJECT NUMBER: 214394CORNELL UNIVERSITY
BAKER LAB - ROOM 240C RENOVATIONS CORNELL UNIVERSITYBAKER LABORATORYROOM 240C RENOVATIONS
&23<5,*+7/$%(//$$662&,$7(6'3&ISSUED FOR:DATE:BID DOCUMENTSJUNE 23, 2014DESCRIPTIONNO.DATEDRAWN BY:APPROVED BY:214394EngineeringArchitectureEnvironmentalPlanningCORNELL UNIVERSITYPROJECT NO:REVISIONFACILITIES MANAGEMENT119 HUMPHREYS SERVICE BUILDINGITHACA, NY 14853ROOM 240C RENOVATIONSDRAWING NAME:DRAWING NO:BAKER LABORATORY259 EAST AVEITHACA, NEW YORK 14850KRGAAGENERAL NOTES1&216758&7,216+$//&21)250727+(´1(:<25.67$7(81,)250),5(3527(&7,21$1'%8,/',1*&2'(µ/$7(675(9,6,217+(1(:<25.67$7((1(5*<&2'($1'$1<27+(5&2'(6GOVERNED BY THE JURISDICTION IN WHICH THE PROJECT IS BEING CONSTRUCTED.2.CONSTRUCTION SHALL COMPLY WITH ALL LOCAL, STATE AND FEDERAL CODES AND REGULATIONS.3.ALL DRAWINGS ARE GRAPHIC REPRESENTATIONS OF APPROXIMATE LOCATIONS OF NEW MATERIALS.IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY ALL CONDITIONS PRIOR TOCOMMENCEMENT OF WORK. CONTRACTOR SHALL NOT SCALE THE DRAWINGS.4.CONTRACTOR IS RESPONSIBLE FOR ALL MATERIALS, CONSTRUCTION METHODS, AND CRAFTSMANSHIP.5.CONTRACTOR IS TO VERIFY ALL EXISTING CONDITIONS, REQUIREMENTS, NOTES, CODES, ANDDIMENSIONS PRIOR TO THE START OF CONSTRUCTION AND SHALL NOTIFY THE ARCHITECT IFCONDITIONS VARY FROM THOSE SHOWN ON THE DOCUMENTS. DO NOT SCALE THE DRAWINGS.6.WHEN EXISTING CONSTRUCTION IS REMOVED, DISTURBED, DAMAGED, REPLACED OR RENOVATED INANY WAY, CONTRACTOR SHALL PROVIDE PATCHING, PAINTING AND MATERIALS OF SAME TYPE ANDQUALITY AS TO MATCH ADJACENT EXISTING SURFACES, UNLESS OTHERWISE NOTED.7.CONTRACTOR IS TO PROVIDE ALL BLOCKING, FURRING AND SHIMMING FOR INSTALLATION ANDCOMPLETION OF WORK.8.ALL NEW WORK SHALL BE PLUMB, LEVEL AND SQUARE. SCRIBE AND MAKE FIT ALL NEW WORK TOEXISTING.9.CONTRACTOR IS TO VERIFY ALL DIMENSIONS BEFORE ORDERING MATERIAL OR DOING WORK. NOEXTRA COMPENSATION OR CHARGES WILL BE ACCEPTED DUE TO DIFFERENCES BETWEEN THE ACTUALMEASUREMENTS AND MEASUREMENTS INDICATED ON THE DRAWINGS. DO NOT SCALE THE DRAWINGS.10.ALL DETAILS ARE SUBJECT TO CHANGE DUE TO EXISTING FIELD CONDITIONS. CONTRACTOR MUSTNOTIFY ARCHITECT OF SAME.11.CONTRACTOR TO COORDINATE ALL DOOR HARDWARE, TRIM AND FINISHES TO MEET INTENT ANDCOMPLIANCE.12.THESE DRAWINGS DO NOT PURPORT TO SHOW ALL ITEMS AND PROCEDURES REQUIRED FOR ACOMPLETE INSTALLATION. THE INTENT IS TO INDICATE THE GENERAL SCOPE OF THE PROJECT INTERMS OF THE GENERAL ARCHITECTURAL DESIGN CONCEPT, THE LOCATION/DIMENSIONS OF THECONSTRUCTION AND MAJOR ELEMENTS OF CONSTRUCTION.13.CONTRACTORS ARE RESPONSIBLE FOR OBTAINING AND PAYING FOR ALL PERMITS ASSOCIATED WITHTHE WORK OF THEIR CONTRACT.14.,7(06127('$6
%<2:1(5µ$5(72%()851,6+('$1',167$//('%<7+(2:1(5257+(2:1(5
6VENDOR.15.OWNER PROVIDED EQUIPMENT IS INDICATED FOR REFERENCE ONLY. COORDINATE AND VERIFYDIMENSIONS AND CLEARANCE REQUIREMENTS WITH ACTUAL EQUIPMENT PROVIDED.16.CONTRACTOR TO PROVIDE FIRESTOPPING AT ALL NEW PENETRATIONS MADE IN EXISTING AND NEWFIRE RATED CONSTRUCTION. REFER TO LIFE SAFETY PLANS.CONCRETE MASONRY UNITS(CMU)CEMENT, SAND, GROUT, PLASTER,OR GYPSUM WALL BOARDEARTHBRICKCONCRETECARPETWOOD (FINISHED)WOOD (ROUGH)PLYWOODSTONE, GRAVEL, OR POROUSFILLSTEELBATT. OR LOOSEINSULATIONRIGID INSULATIONABBREVIATIONSMATERIAL SYMBOLSREFERENCE SYMBOLS3INTERIOR ELEVATIONSHEET NODETAIL NO42X-XXX1BUILDING SECTIONEXTERIOR ELEVATIONWALL SECTION0X-XXXSHEET NODETAIL NODETAIL NOSHEET NOSHEET NO0X-XXXX-XXX0DETAIL NODETAIL REFERENCEMATCH LINES0XX X-XXXMATCH LINEXXXXXXXXXXXXXXELEV. = XXX'-XX"ELEVATIONCUT LINECENTER LINEROOM IDENTIFIERNAMEAREA (SF)ROOMDOOR IDENTIFIERWALL TYPE(REFER TO WALL TYPES FOR KEY)REVISION SYMBOL AND CLOUD1DRAWING TITLENORTH ARROWCLDEMOLITION WALL. G.C. TO PATCH ANDREPAIR EXISTING SURFACES TO REMAIN.PREP SURFACES FOR NEW FINISHESLINE INDICATES ITEM TO BEDEMOLISHED ON DEMO DRAWINGSUNLESS OTHERWISE NOTEDEXISTING WALL TO REMAINNEW STUD FRAMED WALLNEWDOOR MARKEXISTINGDOOR MARKA.EXISTING CONDITIONS ARE TAKEN FROM FIELD OBSERVATIONS AND PRIOR CONSTRUCTION DOCUMENTSWHEN AVAILABLE AND ARE NOT GUARANTEED. CONTRACTOR SHALL FIELD VERIFY ALL EXISTINGCONDITIONS PRIOR TO BID. NO ALLOWANCE WILL BE MADE FOR ADDITIONAL COSTS DUE TOCONTRACTORS FAILURE TO VERIFY EXISTING CONDITIONS AND DIMENSIONS.B.WHEN EXISTING CONSTRUCTION WHICH IS TO REMAIN IS DAMAGED DURING THE COURSE OFCONSTRUCTION AS A RESULT OF CONTRACTORS WORK, IT SHALL BE REPAIRED AND/OR REPLACED WITHSIMILIAR OR LIKE MATERIALS, SUBJECT TO ARCHITECTS APPROVAL AND WITHOUT COMPENSATION.C.CONTRACTOR SHALL DISPOSE OF ALL DEMOLITION AND/OR OTHER WASTE MATERIALS, CAUSED BY THISCONSTRUCTION, OFF SITE IN A PROPER LEGAL MANNER.D.OWNER TO REMOVE, TEMPORARILY STORE AND RELOCATE EXISTING FURNITURE AND ALL EXISTING LOOSEEQUIPMENT ITEMS AS NECESSARY TO ACCOMMODATE DEMOLITION AND RENOVATION.E.COORDINATE DEMOLITION WORK WITH OWNER. OWNER HAS THE RIGHT OF FIRST REFUSAL FOR ALLSCHEDULED REMOVED MATERIALS.GENERAL DEMOLITION NOTESDEMOLITIONDOOR MARK1FMA-SCALEACTACOUSTICAL CEILING TILEADJADJACENTAFFABOVE FINISH FLOORAFGABOVE FINISH GRADEAHUAIR HANDLING UNITALUMALUMINUMALTALTERNATEAPPROXAPPROXIMATE (LY)AVGAVERAGEBLDGBUILDINGBOBOTTOM OFBSMTBASEMENTBURBUILT UP ROOFCFMCUBIC FEET PER MINUTECFMFCOLD FORMED METAL FRAMINGCJCONTROL JOINTCLGCEILINGCLRCLEARCIPCAST IN PLACECMUCONCRETE MASONRY UNITCOLCOLUMNCONCCONRETECONTCONTINUOUSCPTCARPETCUCUBICDEMODEMOLISHDIADIAMETERDWGDRAWINGEC ELECTRICAL CONTRACTOREIFSEXTERIOR INSULATION FINISHSYSTEMELEVELEVATIONEPDMETHYLENE PROPYLENE DIENEMONOMERETREXISTING TO REMAINENGRENGINEEREQEQUALESTESTIMATEDEXIST, EXGEXISTINGEXTEXTERIORFINFINISH (EDFLFLOORFPCFIRE PROTECTION CONTRACTORFTFOOT OR FEETFURNFURNITUREFUTFUTUREGALVGALVANIZEDGCGENERAL CONTRACTORGYBGYPSUM WALL BOARDHCHEATING, VENTILATING AND AIRCONDITIONING CONTRACTORHMHOLLOW METALHVACHEATING, VENTILATING AND AIRCONDITIONINGHORIZHORIZONTALIDINSIDE DIAMETERININCHINSULINSULATIONINTINTERIORLIN FTLINEAL FOOT OR FEETLOCLOCATIONMAXMAXIMUMMFGMANUFACTURERMEMATCH EXISTINGMECHMECHANICALMINMINIMUMMISCMISCELLANEOUSMOMASONRY OPENINGMTDMOUNTEDMTGMOUNTINGNANOT APPLICABLENICNOT IN CONTRACTNRCNOISE RESISTANCE COEFFICIENTNTSNOT TO SCALEOCON CENTEROD OUTSIDE DIAMETEROHOVERHEADOPPOPPOSITE HANDOFCIOWNER FURNISHED CONTRACTORINSTALLEDPCPLUMBING CONTRACTORPLAMPLASTIC LAMINATEPLBGPLUMBINGPRPAIRPTPRESSURE TREATEDPVCPOLYVINYL CLORIDEQTYQUANTITYRDROOF DRAINREFREFERENCEREQREQUIREDROROUGH OPENINGROWRIGHT OF WAYRTUROOF TOP UNITSIMSIMILARSPECSPECIFICATIONSQ FTSQUARE FOOTSQ INSQUARE INCHSSSTAINLESS STEELSTDSTANDARDTBDTO BE DETERMINEDTEMPTEMPORARYTOTOP OFTPOTHERMOPLASTIC POLYOLEFINTYPTYPICALULUNDERWRITER'S LABORATORYUNOUNLESS NOTED OTHERWISEVCTVINYL COMPOSITION TILEVERTVERTICALVIFVERIFY IN FIELDVOLVOLUMNW/WITHW/OWITHOUTMECEILING HEIGHT, AFF UNLESSNOTED OTHERWISEDRAWING INDEX:GENERALCOVER SHEETG-001DRAWING INDEX, GENERAL NOTES, SYMBOLS, AND ABBREVIATIONSLIFE SAFETYLS-001SECOND FLOOR CODE REVIEW AND LIFE SAFETY PLANARCHITECTURALA-011PARTIAL SECOND FLOOR DEMOLITION PLANA-101PARTIAL SECOND FLOOR CONSTRUCTION AND REFLECTED CEILING PLANSA-200INTERIOR ELEVATIONSA-500WALL TYPES AND DETAILSMECHANICALM-001SYMBOLS, ABBREVIATIONS AND GENERAL NOTESM-101PARTIAL SECOND FLOOR MECHANICAL PLANM-102DETAILS AND SCHEDULESELECTRICALE-001GENERAL NOTES, SCHEDULES, SYMBOLS & ABBREVIATIONSE-101PARTIAL DEMOLITION, LIGHTING AND POWER PLANSPROJECT LOCATION MAPNLOCATION OF WORK
44'3 OCC.4 OCC.LOCATION OF EXISTINGEYE WASH ANDEMERGENCY SHOWER&23<5,*+7/$%(//$$662&,$7(6'3&ISSUED FOR:DATE:BID DOCUMENTSJUNE 23, 2014DESCRIPTIONNO.DATEDRAWN BY:APPROVED BY:214394EngineeringArchitectureEnvironmentalPlanningCORNELL UNIVERSITYPROJECT NO:REVISIONFACILITIES MANAGEMENT119 HUMPHREYS SERVICE BUILDINGITHACA, NY 14853ROOM 240C RENOVATIONSDRAWING NAME:DRAWING NO:BAKER LABORATORY259 EAST AVEITHACA, NEW YORK 14850KEYPLANNTSNKRGAALS-1011N1/16" = 1'-0"SECOND FLOOR LIFE SAFETY PLANAREA OF WORKCHAPTER 3 - USE AND OCCUPANCY CLASSIFICATION:BUSINESS GROUP BSECTION 305.1 CHAPTER 5 - GENERAL BUILDING CODE HEIGHTS AND AREAS:ALLOWABLE BUILDING HEIGHTTABLE 5034 STORIES 4 STORIESEXISTING NON-CONFORMINGALLOWABLE BUILDING AREASTABLE 50319,000 SF154,372 SFEXISTING NON-CONFORMINGINCIDENTAL USE AREASTABLE 508.2CHAPTER 6 - TYPES OF CONSTRUCTIONCONSTRUCTION CLASSIFICATIONSECTION 602TYPE IIBFIRE RESISTANCE RATING REQ. FOR BUILDING ELEMENTSSTRUCTURAL FRAMETABLE 6010 HREXISTINGBEARING WALLS - EXTERIOR/INTERIORTABLE 6010 HREXISTINGNONBEARING WALLS - EXTERIOR/INTERIORTABLE 601O HREXISTINGFLOOR CONSTRUCTIONTABLE 6010 HREXISTINGROOF CONSTRUCTIONTABLE 6010 HREXISTINGINCIDENTAL USE AREASTABLE 508.2FURNACE >400K BTU/HRTABLE 508..21 HREXISTINGBOILER >15 PSI&10 HPTABLE 508.21 HR EXISTINGREFRIGERANT MACHINE RMSTABLE 508.21 HR EXISTINGLABORATORIES/SHOPSTABLE 508.21 HR EXISTINGSTORAGE ROOMS >100 SFTABLE 508.21 HR EXISTINGCHAPTER 7 - FIRE RESISTANCE - RATED CONSTRUCTIONFIRE BARRIERS TABLE 706.3.92 HREXISTINGSHAFT ENCLOSURESSECTION 707.41 HREXISTING LESS THAN 4 STORIESFIRE PARTITIONSSECTION 708.31 HREXISTINGSMOKE BARRIERSSECTION 709.31 HREXISTINGCHAPTER 8 - INTERIOR FINISHESEXIT ENCLOSURES AND EXIT PASSAGEWAYSTABLE: 803.5CLASS A (NON-SPRINKLERED)CORRIDORSTABLE: 803.5CLASS B(NON-SPRINKLERED)ROOMS AND ENCLOSED SPACESTABLE: 803.5CLASS C(NON-SPRINKLERED)INTERIOR FLOOR FINISHSECTION: 804.4.1CLASS IICHAPTER 9 - FIRE PROTECTION SYSTEMSAUTOMATIC SPRINKLERSECTION: 903.2.21 NON-SPRINKLERD NOT APPLICABLEREQUIRED (FIRE AREAS>20,000 SF.)PORTABLE FIRE EXT.SECTION: 906REQUIRED EXISTING - 75' TRAVEL DISTANCE - FIRE CODE OF NYSFIRE ALARM (MANUAL)SECTION: 907REQUIRED-----ROOMS, DUCT DETECTORSSECTION: 9072.12.1REQUIRED-----CHAPTER 10 - MEAN OF EGRESSOCCUPANT LOADSECTION 1004---------REFER TO PLAN FOR OCCUPANT LOADSBUSINESSTABLE: 1004.1.1100 GROSS-----ASSEMBLYTABLE: 1004.1.115 NET-----EDUCATIONAL - SHOPSTABLE: 1004.1.150 NET-----DOORS: WIDTHSECTION: 100832" MIN. CLEAR34" MIN.SWINGSECTION: 1008.1.2SEE COMMENTPROVIDEDIN DIRECTION OF EXIT SERVING OCCUPANT LOADOF 50 OR MORE.PANIC AND FIRE EXIT HARDWARESECTION: 1008.1.9REQUIREDPROVIDEEXIT ACCESSSECTION: 1014-----N/ACOMMON PATH OF EGRESS TRAVELSECTION: 1014.375 FEETN/AEXISTINGEXIT AND EXIT ACCESS DOORWAYSSECTION: 10152 EXITSCOMPLIESEXCEPTIONTABLE: 1015.11 EXIT SEE COMMENT49 OR LESS OCCUPANTSEXIT ACCESS TRAVEL DISTANCETABLE: 1016.1200 FEET MAX. CORRIDORSTABLE: 1017.11 HOUREXISTINGDEAD-END CORRIDORSSECTION: 1017.320 FEET MIN.COMPLIESCHAPTER 11 - ACCESSIBILITYACCESSIBLE ROUTE: CONNECTED SPACESSECTION: 1104.31 MIN.COMPLIESACCESSIBLE ENTRANCESSECTION: 110560% MIN.COMPLIESBUILDING CODE NYS 2010 (BCNYS)REQUIRED\CODE ITEMS:CODE SECTION:ALLOWEDACTUALCOMMENTSEXISTING BUILDING CODE NYS 2010 (EBNYS)REQUIRED\CODE ITEMS:CODE SECTION:ALLOWEDACTUALCOMMENTSCHAPTER 4 - CLASSIFICATION OF WORKREPAIRSSECTION: 402 ----------PATCHING OR RESTORATION OF REPLACEMENT OFDAMAGED MATERIALS, ELEMENTS, EQUIPMENT OR FIXTURES FOR PURPOSE OF MAINTAINING SUCH COMPONENTS IN GOOD OR SOUND CONDITION WITH TOEXISTING LOADS OR PERFORMANCE REQUIREMENTS.CHAPTER 5 - REPAIRSPERMITTED MATERIALSSECTION: 501.2----------MATERIALS PERMITTED BY THE APPLICABLE CODE FORNEW CONSTRUCTION. LIKE MATERIALS SHALL BE PERMITTED, PROVIDED NO HAZARD TO LIFE.CONFORMANCESECTION: 501.3----------WORK SHALL NOT MAKE THE BUILDING LESS CONFORMING THAN IT WAS BEFORE THE REPAIRELECTRICAL WORKSECTION: 507----------SHALL BE ALLOWED TO BE REPAIRED OR REPLACEDWITH LIKE MATERIALS.MECHANICAL WORKSECTION: 508----------SHALL NOT MAKE THE BUILDING LESS CONFORMINGPLUMBING WORKSECTION: 509----------MATERIALS AND SUPPLIES SHALL NOT BE USED THATARE PROHIBITED IN THE PLUMBING CODE OF NYS.LIFE SAFETY LEGEND:# EU150'# OCC.INDICATES TRAVEL DISTANCE TO AN EXITFIRE EXTINGUISHER CABINET1 HOUR FIRE BARRIER W/ 45 MIN OPENING PROTECTION2 HOUR FIRE BARRIER W/ 90 MIN OPENING PROTECTIONINDICATES OCCUPANCY LOADINDICATES EXIT CLEARANCE PROVIDED IN INCHES# OLINDICATES EXIT CLEARANCE OCCUPANCY LOAD (PERSONS)1 HOUR FIRE PARTITION W/ 20 MIN OPENING PROTECTIONAREAS OF ALTERATION - LEVEL 2EXISTING CONSTRUCTION TO REMAINCLASSIFICATION OF WORK KEY:
12331&23<5,*+7/$%(//$$662&,$7(6'3&ISSUED FOR:DATE:BID DOCUMENTSJUNE 23, 2014DESCRIPTIONNO.DATEDRAWN BY:APPROVED BY:214394EngineeringArchitectureEnvironmentalPlanningCORNELL UNIVERSITYPROJECT NO:REVISIONFACILITIES MANAGEMENT119 HUMPHREYS SERVICE BUILDINGITHACA, NY 14853ROOM 240C RENOVATIONSDRAWING NAME:DRAWING NO:BAKER LABORATORY259 EAST AVEITHACA, NEW YORK 14850KEYPLANNTSNKRGAAA-1011N1/4" = 1'-0"PARTIAL SECOND FLOOR CONSTUCTION PLANAREA OF WORKGENERAL DEMOLITION NOTES:A.EXISTING CONDITIONS ARE TAKEN FROM FIELD OBSERVATIONS AND PRIORCONSTRUCTION DOCUMENTS WHEN AVAILABLE AND ARE NOT GUARANTEED.CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO BID. NOALLOWANCE WILL BE MADE FOR ADDITIONAL COSTS DUE TO CONTRACTORSFAILURE TO VERIFY EXISTING CONDITIONS AND DIMENSIONS.B.WHEN EXISTING CONSTRUCTION WHICH IS TO REMAIN IS DAMAGED DURINGTHE COURSE OF CONSTRUCTION AS A RESULT OF CONTRACTORS WORK, ITSHALL BE REPAIRED AND/OR REPLACED WITH SIMILAR OR LIKE MATERIALS,SUBJECT TO ARCHITECTS APPROVAL AND WITHOUT COMPENSATION.C.CONTRACTOR SHALL DISPOSE OF ALL DEMOLITION AND/OR OTHER WASTEMATERIALS, CAUSED BY THIS CONSTRUCTION, OFF SITE IN A PROPER LEGALMANNER.D.OWNER TO REMOVE, TEMPORARILY STORE AND RELOCATE EXISTINGFURNITURE AND ALL EXISTING LOOSE EQUIPMENT ITEMS AS NECESSARY TOACCOMMODATE DEMOLITION AND RENOVATION.E.COORDINATE DEMOLITION WORK WITH OWNER. OWNER HAS THE RIGHT OFFIRST REFUSAL FOR ALL SCHEDULED REMOVED MATERIALS.KEYED DEMOLITION NOTES:REMOVE EXISTING FLOORING, MASTIC, RESILIENT BASE AND ALL ASSOCIATEDCOMPONENTS. PROVIDE CEMENTITIOUS LEVELING UNDERLAYMENT AS REQUIREDTO BRING FLOOR TO LEVEL. PATCH EXPOSED SURFACE TO MATCH EXISTINGADJACENT SURFACES AND PREPARE AS REQUIRED FOR SCHEDULED FINISHES.EXISTING COVE BASE TO REMAIN.REMOVE EXISTING SUSPENDED CEILING SYSTEM INCLUDING PANELS, GRID,SUSPENSION WIRES AND ALL ASSOCIATED COMPONENTS IN THEIR ENTIRETY.REMOVE WINDOW LATCHING HARDWARE AND MODIFY STEEL FRAME AS REQUIREDTO INSTALL SCHEDULED SECONDARY WINDOW SYSTEM. MECHANICALLY FASTENOPERABLE PORTION OF WINDOW AT LOCATIONS AND SPACING TO PREVENTOPERATION.123
MA-4F-A-20187109A-2011532A-2014562MA-4F-MA-4F-123255326F1F1554BBAAM8A2A1A2cA2aA3bdB1EM+40" AFF+40" AFF+34" AFF+34" AFF9'-0" VIF9'-0" VIF9'-0" VIFC1C1C1&23<5,*+7/$%(//$$662&,$7(6'3&ISSUED FOR:DATE:BID DOCUMENTSJUNE 23, 2014DESCRIPTIONNO.DATEDRAWN BY:APPROVED BY:214394EngineeringArchitectureEnvironmentalPlanningCORNELL UNIVERSITYPROJECT NO:REVISIONFACILITIES MANAGEMENT119 HUMPHREYS SERVICE BUILDINGITHACA, NY 14853ROOM 240C RENOVATIONSDRAWING NAME:DRAWING NO:BAKER LABORATORY259 EAST AVEITHACA, NEW YORK 14850KEYPLANNTSNKRGMDA-1011N1/4" = 1'-0"PARTIAL SECOND FLOOR CONSTUCTION PLANA-10121/4" = 1'-0"PARTAIL SECOND FLOOR REFELECTED CEILING PLANGENERAL NOTES:1.ASBESTOS CONTAINING MATERIALS (ACM) WILL BE MANAGED BY OWNERINCLUDING TESTING AND ABATEMENT UNDER SEPARATE CONTRACTS. IFCONTRACTORS UNCOVER OR SUSPECT ACM THEY ARE TO STOP WORK ANDNOTIFY OWNER.2.ALL ACCESSIBLE COMPONENTS MUST COMPLY WITH ADA STANDARDS,ICC/ANSI A117.1 STANDARDS, AND CORNELL UNIVERSITY DESIGN STANDARDS.ALL OTHER FIXTURES MAY BE MOUNTED AT STANDARD HEIGHTS.3.REFER TO G-001 FOR ADDITIONAL GENERAL NOTES.NAREA OF WORKKEYED CONSTRUCTION NOTES:DOOR, SEE DOOR SCHEDULE.WINDOW TYPE, SEE SHEET A-500PROVIDE WOOD BASE CABINETS AND EPOXY RESIN COUNTERTOP, REFER TOELEVATIONS AND MILLWORK FINISH NOTES.PROVIDE WALL MOUNTED SHELVING, REFER TO ELEVATIONS.PROVIDE WALL MOUNTED EPOXY RESIN WORK SURFACE, REFER TO ELEVATIONS.PROVIDE STAINLESS STEEL CART, F-5349-00 BY KEWAUNEE OR APPROVED EQUAL.PROVIDE STOOL, F-4946-00 KEWAUNEE OR APPROVED EQUAL.PROVIDE ROLLER SHADE, RB-500 BY HUNTER DOUGLASS - SHEERWEAVE 2703123456#LIGHT FIXTURE, SEE ELECTRICAL DRAWINGSWALL MOUNTED LIGHT FIXTURE,SEE ELECTRICAL DRAWINGSTEMPERATURE SENSOR, SEE ELECTRICAL DRAWINGSCEILING GRILL, SEE MECHANICAL DRAWINGSCEILING DIFFUSER, SEE MECHANICAL DRAWINGSCEILING LEGENDOCCUPANCY SENSOR, SEE ELECTRICAL DRAWINGS2' x 4' ACOUSTIC PANEL CEILINGSMOKE DETECTOR, SEE ELECTRICAL DRAWINGSX'-X"CEILING HEIGHT, ABOVE FINISH FLOOR U.N.O.1.REFER TO KEYED FINISH NOTES FOR CEILING TYPE COMPOSITION AND FINISH.2.LIGHTING AND OTHER CEILING MOUNTED EQUIPMENT ARE SHOWN FOR CLARITY.COORDINATE ALL CEILING WORK PRIOR TO INSTALLATION OF CEILING SYSTEMS.3.ALL CEILING MOUNTED ITEMS ARE TO BE CENTERED IN THE CEILING PANEL ANDGRIDS UNLESS THE PANELS ARE SCORED. CENTER ITEMS WITHIN THE PATTERN OFSCORED PANELS.4.PATCH ALL DISTURBED WALLS TO MATCH EXISTING.GENERAL RCP NOTES:FIRE ALARM, SEE ELECTRICAL DRAWINGSKEYED FINISH NOTES:PAINTGENERAL PAINT SPECIFICATIONS:FOR GWB PARTITIONS:1ST COAT: BENJAMIN MOORE FRESH START LOW ODOR INTERIOR LATEX PRIMER2ND COAT: BENJAMIN MOORE SUPER SPEC INTERIOR LATEX EGGSHELL3RD COAT: BENJAMIN MOORE SUPER SPEC INTERIOR LATEX EGGSHELLHOLLOW METAL FRAMES:1ST COAT: BENJAMIN MOORE SUPER SPEC HP ACRYLIC METAL PRIMER2ND COAT: BENJAMIN MOORE SUPER SPEC INTERIOR LATEX EGGSHELL3RD COAT: BENJAMIN MOORE SUPER SPEC INTERIOR LATEX EGGSHELLPAINT WALLS, COLOR TO BE BENJAMIN MOORE 612 "LINEN WHITE"PAINT DOOR FRAME, COLOR TO BE BENJAMIN MOORE 612 "LINEN WHITE"PAINT EXISTING HEATING UNIT SHROUD, COLOR TO MATCH WALLCEILINGCEILING GRID: ARMSTRONG PRELUDE XL 15/16" EXPOSED TEE SYSTEM, WHITE.CEILING PANEL: ARMSTRONG 24 x 24 x 15/16" CIRRUS SECOND LOOK II (513), WHITE.FLOORINGVCT: ARMSTONG STANDARD EXCELON IMPERIAL, ANTIQUE WHITE (51811).BASEVINYL BASE: ARMSTONG TOLOR INTEGRATED VINYL BASE, 4" HIGH, JET BLACK (60)EXISTING COVE BASE TO REMAIN..MILLWORKGENERAL MILLWORK SPECIFICATIONS:BASE CABINETS TO BE SIGNATURE SERIES - CONTEMPORARY FULL OVERLAY - STYLE 5BY KEWAUNEE SCIENTIFIC CORPORATION OR APPROVED EQUAL. RED OAK VENEERFINISH. 3/8" DIA SS ROD PULL IN BRUSHED SATIN FINISH. PROVIDE EXTENDED ENDPANELS AT EXPOSED ENDS. KEYED DIFFERENT AT ALL DOORS AND DRAWERS.ADA ACCESSIBLE BASE CABINET WITH DOORS5 DRAWER BASE CABINETBLIND CORNER BASE CABINETDRAWER AND CUPBOARD BASE CABINET30" x 30" STAINLESS STEEL PEGBOARD WITH DRIP TROUGH12" DEEP METAL SHELVING ON ABOVE COUNTERTOP WALL SUSPENSION SYSTEM9" DEEP METAL SHELVING ON ABOVE COUNTERTOP WALL SUSPENSION SYSTEM24" x 72" MODULAR WORKSTATION SIMILAR TO ENTERPRISE BY KEWAUNEE, SEEELEVATIONS AND DETAIL 12/A-500.FILLER, VERIFY SIZE IN FIELDWOOD PIPE CHASE, COORDINATE DEPTH WITH PLUMBING DRAWINGSEPOXY COUNTERTOPALL COUNTERTOPS TO BE 1" THICK EPOXY RESIN, BLACK. SEE ELEVATIONS FORDEPTHS. PROVIDE 4" HIGH BACKSPLASH AT ALL FIXED COUNTERTOPS AT ALLADJACENT WALLS.STAINLESS STEEL COUNTERTOP SUPPORTS - STREAMLINE BY FEDERAL BRACE ORAPPROVED EQUAL, OVERHANG NOT TO EXCEED 4" OR AS REQ'D BY COUNTERTOPMANUF.ACCESORIESREFER TO ACCESSORY SCHEDULE 11/A-500 FOR INFORMATION AND MOUNTINGHEIGHTS.P1P2C1F1B1M1M2M3M4M5M6M7M8M9M10E1E2P3B2Ax
FINISH FLOOR0'-0"CEILING
$))SHELF6'-3" A.F.F.SHELF5'-3" A.F.F.M6M1M2M3M5M9M10E1B1P1M6A1FINISH FLOOR0'-0"CEILING
$))FINISH FLOOR0'-0"CEILING
$))SHELF6'-3" A.F.F.SHELF5'-3" A.F.F.E1B2B1P1P1BBA-5008A-5007P3A2A1FINISH FLOOR0'-0"CEILING
$))FINISH FLOOR0'-0"CEILING
$))SHELF6'-3" A.F.F.SHELF5'-3" A.F.F.SHELF4'-3" A.F.F.M6M7M6E1B1B1P1P2E2TYP.FINISH FLOOR0'-0"CEILING
$))FINISH FLOOR0'-0"CEILING
$))SHELF6'-3" A.F.F.SHELF5'-3" A.F.F.SHELF4'-3" A.F.F.M6M7M6M6M6M4E1E1B1B2P1P1P1E2FINISH FLOOR0'-0"CEILING
$))FINISH FLOOR0'-0"CEILING
$))B1P1P2FINISH FLOOR0'-0"CEILING
$))FINISH FLOOR0'-0"CEILING
$))SHELF6'-3" A.F.F.SHELF5'-3" A.F.F.SHELF4'-3" A.F.F.M6M7M6E1B1B1P1P1P2E2TYP.M6M7M6FINISH FLOOR0'-0"CEILING
$))FINISH FLOOR0'-0"CEILING
$))B1B1P1P2FINISH FLOOR0'-0"CEILING
$))FINISH FLOOR0'-0"CEILING
$))M8B1B1P1P1FINISH FLOOR0'-0"CEILING
$))FINISH FLOOR0'-0"CEILING
$))SHELF6'-3" A.F.F.SHELF5'-3" A.F.F.SHELF4'-3" A.F.F.E1M8B1B1P1P2E2TYP.M6M7M6FINISH FLOOR0'-0"CEILING
$))FINISH FLOOR0'-0"CEILING
$))E1B2P1E2AATYP.A-5008SIMA-5007P37M6M7M6SHELF6'-3" A.F.F.SHELF5'-3" A.F.F.SHELF4'-3" A.F.F.M8FINISH FLOOR0'-0"CEILING
$))&23<5,*+7/$%(//$$662&,$7(6'3&ISSUED FOR:DATE:BID DOCUMENTSJUNE 23, 2014DESCRIPTIONNO.DATEDRAWN BY:APPROVED BY:214394EngineeringArchitectureEnvironmentalPlanningCORNELL UNIVERSITYPROJECT NO:REVISIONFACILITIES MANAGEMENT119 HUMPHREYS SERVICE BUILDINGITHACA, NY 14853ROOM 240C RENOVATIONSDRAWING NAME:DRAWING NO:BAKER LABORATORY259 EAST AVEITHACA, NEW YORK 14850KRGAAKEYED FINISH NOTES:PAINTGENERAL PAINT SPECIFICATIONS:FOR GWB PARTITIONS:1ST COAT: BENJAMIN MOORE FRESH START LOW ODOR INTERIOR LATEX PRIMER2ND COAT: BENJAMIN MOORE SUPER SPEC INTERIOR LATEX EGGSHELL3RD COAT: BENJAMIN MOORE SUPER SPEC INTERIOR LATEX EGGSHELLHOLLOW METAL FRAMES:1ST COAT: BENJAMIN MOORE SUPER SPEC HP ACRYLIC METAL PRIMER2ND COAT: BENJAMIN MOORE SUPER SPEC INTERIOR LATEX EGGSHELL3RD COAT: BENJAMIN MOORE SUPER SPEC INTERIOR LATEX EGGSHELLPAINT WALLS, COLOR TO BE BENJAMIN MOORE 612 "LINEN WHITE"PAINT DOOR FRAME, COLOR TO BE BENJAMIN MOORE 612 "LINEN WHITE"PAINT EXISTING HEATING UNIT SHROUD, COLOR TO MATCH WALLCEILINGCEILING GRID: ARMSTRONG PRELUDE XL 15/16" EXPOSED TEE SYSTEM, WHITE.CEILING PANEL: ARMSTRONG 24 x 24 x 15/16" CIRRUS SECOND LOOK II (513), WHITE.FLOORINGVCT: ARMSTONG STANDARD EXCELON IMPERIAL, ANTIQUE WHITE (51811).BASEVINYL BASE: ARMSTONG TOLOR INTEGRATED VINYL BASE, 4" HIGH, JET BLACK (60)EXISTING COVE BASE TO REMAIN..MILLWORKGENERAL MILLWORK SPECIFICATIONS:BASE CABINETS TO BE SIGNATURE SERIES - CONTEMPORARY FULL OVERLAY - STYLE 5BY KEWAUNEE SCIENTIFIC CORPORATION OR APPROVED EQUAL. RED OAK VENEERFINISH. 3/8" DIA SS ROD PULL IN BRUSHED SATIN FINISH. PROVIDE EXTENDED ENDPANELS AT EXPOSED ENDS. KEYED DIFFERENT AT ALL DOORS AND DRAWERS.ADA ACCESSIBLE BASE CABINET WITH DOORS5 DRAWER BASE CABINETBLIND CORNER BASE CABINETDRAWER AND CUPBOARD BASE CABINET30" x 30" STAINLESS STEEL PEGBOARD WITH DRIP TROUGH12" DEEP METAL SHELVING ON ABOVE COUNTERTOP WALL SUSPENSION SYSTEM9" DEEP METAL SHELVING ON ABOVE COUNTERTOP WALL SUSPENSION SYSTEM24" x 72" MODULAR WORKSTATION SIMILAR TO ENTERPRISE BY KEWAUNEE, SEEELEVATIONS AND DETAIL 12/A-500.FILLER, VERIFY SIZE IN FIELDWOOD PIPE CHASE, COORDINATE DEPTH WITH PLUMBING DRAWINGSEPOXY COUNTERTOPALL COUNTERTOPS TO BE 1" THICK EPOXY RESIN, BLACK. SEE ELEVATIONS FORDEPTHS. PROVIDE 4" HIGH BACKSPLASH AT ALL FIXED COUNTERTOPS AT ALLADJACENT WALLS.STAINLESS STEEL COUNTERTOP SUPPORTS - STREAMLINE BY FEDERAL BRACE ORAPPROVED EQUAL, OVERHANG NOT TO EXCEED 4" OR AS REQ'D BY COUNTERTOPMANUF.ACCESORIESREFER TO ACCESSORY SCHEDULE 11/A-500 FOR INFORMATION AND MOUNTINGHEIGHTS.P1P2C1F1B1M1M2M3M4M5M6M7M8M9M10E1E2P3B2AxKEYED CONSTRUCTION NOTES:DOOR, SEE DOOR SCHEDULE.WINDOW TYPE, SEE SHEET A-500PROVIDE WOOD BASE CABINETS AND EPOXY RESIN COUNTERTOP, REFER TOELEVATIONS AND MILLWORK FINISH NOTES.PROVIDE WALL MOUNTED SHELVING, REFER TO ELEVATIONS.PROVIDE WALL MOUNTED EPOXY RESIN WORK SURFACE, REFER TO ELEVATIONS.PROVIDE STAINLESS STEEL CART, F-5349-00 BY KEWAUNEE OR APPROVED EQUAL.PROVIDE STOOL, F-4946-00 KEWAUNEE OR APPROVED EQUAL.PROVIDE ROLLER SHADE, RB-500 BY HUNTER DOUGLASS - SHEERWEAVE 2703123456#A-20111/2" = 1'-0"INTERIOR ELEVATIONA-20121/2" = 1'-0"INTERIOR ELEVATIONA-20131/2" = 1'-0"INTERIOR ELEVATIONA-20141/2" = 1'-0"INTERIOR ELEVATIONA-20151/2" = 1'-0"INTERIOR ELEVATIONA-20161/2" = 1'-0"INTERIOR ELEVATIONA-20171/2" = 1'-0"INTERIOR ELEVATIONA-20181/2" = 1'-0"INTERIOR ELEVATIONA-20191/2" = 1'-0"INTERIOR ELEVATIONA-201101/2" = 1'-0"INTERIOR ELEVATION
A-50021/4" = 1'-0"TYPICAL DOOR TYPEFSEESCHEDULESEE SCHEDULE
FLUSH (CHASE)GSEESCHEDULESEE SCHEDULE
HALF GLASS6"6"8"3'-7"A-50031/4" = 1'-0"TYPICAL FRAME TYPESEE
SCHEDULED
100SEESCHEDULED2"2"2"478"578"DBL STUDHEADER. TYPICAL.12"12"2"SEE PLANS FORWALL TYPE16 GA WELDEDH.M. FRAME, TYP.47 8"
57 8"DRYWALL ANCHOR. TYP.DBL STUDS ATJAMBS. TYPICAL.12"12"16 GA WELDEDH.M. FRAME, TYP.2"SEE PLANS FORWALL TYPE58" GYPSUM WALLBOARD ANDSCHEDULED WALL FINISH. REFERALSO TO GENERAL NOTES.METAL STUDS @ 16"o.c.SIZE AS SCHEDULEDSOUND ATTENUATION BATTINSULATION, THICKNESS TOMATCH STUD SIZE.ACOUSTICAL OR FIRESTOPSEALANT (BOTH SIDES).NONEFIRERATING---FIRETEST47STCRATINGSTC RATING VARIES W/ SUBSTRATEREMARKS11 HOURUL U46547FIRE RATED GYPSUM BOARD ANDFIRESTOP SEALANT REQUIREDSCHEDULED CEILING FINISH.CEILINGSEE RCPFLOOR SLAB/DECK358" METAL STUDDEFLECTION TRACKANCHORED TO DECK.ACOUSTICAL OR FIRESTOPSEALANT (BOTH SIDES).BOTTOM OF DECKELEVATION VARIES58" GYPSUM WALLBOARD ANDSCHEDULED WALL FINISH. REFERALSO TO GENERAL NOTES.METAL STUDS @ 16"o.c.SCHEDULED BASENONEFIRERATING---FIRETEST---STCRATINGSTC RATING VARIES W/ SUBSTRATEREMARKSSCHEDULED CEILING FINISH.CEILINGSEE RCPFLOOR SLAB/DECK358" METAL STUDDEFLECTION TRACKANCHORED TO DECK.ACOUSTICAL SEALANTBOTTOM OF DECKELEVATION VARIESF - EXISTING (TO BE FURRED)SUBSTRATE MATERIAL:W - WOODN - KNEE WALLC - CMUM - METAL STUDSC - CEILING - 4" ABOVE CEILING SYSTEMHOURLY FIRE RATINGSPECIFIC DESCRIPTIONWALL HEIGHT1FMA-PARTITION REMARKSWALL TYPE (CONFIGURATION)NOMINAL SUBSTRATE SIZEPARTITION SCHEDULER ---F - FULL HEIGHT (UNDERSIDE OF DECK) UNLESS NOTED OTHERWISEMA-4F-MC-4F-GENERAL PARTITION NOTES:1.REFER TO CODE REVIEW PLANS TO DETERMINE THEAPPLICABLE FIRE RATING FOR A GIVEN PARTITION TYPE.2.REFER TO ELEVATIONS TO DETERMINE APPLICABLEFINISHES.3.METAL STUD WALLS HAVE THE FOLLOWING MINIMUMREQUIREMENTS:3.A.20 GAUGE FRAMING AT 16"o.c. MIN.3.B.LATERAL BRACING AT 4'-0"o.c. VERTICAL.3.C.DOUBLE NESTED STUDS AT THE PERIMETER OF ALLOPENINGS.3.D.DIAGONAL BRACING AT ALL OPENINGS. SPACEBRACING AT 48" MAX.; MIN. 2 DIAGONAL BRACESPER OPENING (ONE ABOVE EACH JAMB).3.E.ACOUSTICAL SEALANT AT TOP TRACK, BOTTOMTRACK, & ALL PENETRATIONS IN NON-RATEDPARTITIONS.3.F.SOUND ATTENUATING BATT INSULATION FULLHEIGHT WHERE INDICATED.4.WALL PARTITION DETAILS DEPICT "TYPICAL" PARTITIONWIDTH. REFER TO DIMENSIONS ON FLOOR PLAN FORLOCATIONS WHERE PARTITION WIDTH MAY VARY.5.PROVIDE 20 GA. METAL STRIPS x 12" WIDE AT FLOOR ANDOTHER STRIPS FOR ATTACHMENT OF WALL AND TALLCABINETS, WARDROBES TB/CB TOP AND BOTTOM TYP.ACOUSTICAL SEALANTMETAL STUD TRACKANCHORED TO FLOOR.SCHEDULED BASEMETAL STUD TRACKANCHORED TO FLOOR.BAGLAZING TO BE AS FOLLOWS:OVERALL THICKNESS - 1"OUTDOOR LITE - 1/4" CLEAR FULLYTEMPERED GLASSINTERSPACE - PURGED DRYHERMETIC AIRINDOOR LITE - 1/4" CLEAR FULLYTEMPERED GLASSGLAZING TO BE MAPES ARCHITECTURALINSULATED METAL PANEL AS FOLLOWS:OVERALL THICKNESS - 1"OUTDOOR FINISH SURFACE - STANDARD.032 ALUMINUM WITH KYNARFINISH, SMOOTH "BONE WHITE"SUBSTRATE - 4mm CEMENT BOARDCORE - ISOCYANURATE INSULATIONSUBSTRATE - 4mm CEMENT BOARDINDOOR FINISH SURFACE - STANDARD.032 ALUMINUM WITH KYNARFINISH, SMOOTH "BONE WHITE"A-5008A-5007A-5008A-5007EXISTING WINDOW TO REMAINSEE WINDOW TYPE FORGLAZINGEXISTING EXTERIOR WALLALUM GLAZING STOPSSIMILAR TO TUBELITEEXTRUSIONS E0929 ANDE0927 AND GLAZINGGASKET. ALL FASTENERSTO BE STAINLESS STEELHEATER BELOWALUMINUM CHANNELSIMILAR TO TUBELITE# E0302SHIM, BACKER ROD AND SEALANT,TYP. AT PERIMETEREXISTING WINDOW TO REMAINSEE WINDOW TYPE FORGLAZINGEXISTING EXTERIOR WALLHEATER BELOWALUM GLAZING STOPS SIMILARTO TUBELITE EXTRUSIONSE0929 AND E0927 AND GLAZINGGASKET. ALL FASTENERS TOBE STAINLESS STEELSHIM, BACKER ROD ANDSEALANT, TYP. AT PERIMETEREXTERIORINTERIORINTERIOREXTERIOR2'-0"1"3'-0"4"
2'-11"1"1"WOOD CASEWORK,RED OAK VENEERBASE AS SCHEDULEDEPOXY RESINCOUNTERTOP,BLACK2'-3"
MIN.
2'-10"
9"
MIN.8"MIN.2'-2"AT ADA SINK CABINET ONLYSUPPLY PIPING, SEEPLUMBING DRAWINGSEPOXY RESIN DROP-IN SINKBY CASEWORK MANUF. -1005-ADA-DI-BKPROVIDE PROTECTIVEPIPE INSULATION ATEXPOSED DRAIN PIPESREQUIRED KNEE CLEARANCEPIPE CHASE BYCASEWORK MANUF.MIXING FAUCET W-0354-OVBY KEWAUNEE OR EQUAL.PROVIDE ADA WRIST BLADEHANDLES AND AERATORDEIONIZED FAUCETW-0409-O0 BYKEWAUNEE OR EQUAL11"212"12"A2A1PAPER TOWEL DISPENSERSURFACE MOUNT2482-11 BY BRADLEY CO.SATIN SS FINISHSOAP DISPENSERSURFACE MOUNT6562 BY BRADLEY CO.SATIN SS FINISH&23<5,*+7/$%(//$$662&,$7(6'3&ISSUED FOR:DATE:BID DOCUMENTSJUNE 23, 2014DESCRIPTIONNO.DATEDRAWN BY:APPROVED BY:214394EngineeringArchitectureEnvironmentalPlanningCORNELL UNIVERSITYPROJECT NO:REVISIONFACILITIES MANAGEMENT119 HUMPHREYS SERVICE BUILDINGITHACA, NY 14853ROOM 240C RENOVATIONSDRAWING NAME:DRAWING NO:BAKER LABORATORY259 EAST AVEITHACA, NEW YORK 14850KRGAAA-50041 1/2" = 1'-0"TYPICAL HEAD DETAILA-50051 1/2" = 1'-0"TYPICAL JAMB DETAILA-50013/4" = 1'-0"TYPICAL WALL TYPESA-50061/4" = 1'-0"WINDOW TYPESA-50071 1/2" = 1'-0"WINDOW HEAD AND SILL DETAILA-50081 1/2" = 1'-0"WINDOW HEAD AND SILL DETAILA-50091" = 1'-0"TYPICAL SCIENCE CASEWORK DETAILA-500101" = 1'-0"ADA SINK AND KNEE CLEARNACE DETAILA-500111/2" = 1'-0"ACESSORY SCHEDULE AND MOUNTING HEIGHTSA-500121/2" = 1'-0"MODULAR WORK STATION DETAIL
&23<5,*+7/$%(//$$662&,$7(6'3&ISSUED FOR:DATE:BID DOCUMENTSJUNE 23, 2014DESCRIPTIONNO.DATEDRAWN BY:APPROVED BY:214394EngineeringArchitectureEnvironmentalPlanningCORNELL UNIVERSITYPROJECT NO:REVISIONFACILITIES MANAGEMENT119 HUMPHREYS SERVICE BUILDINGITHACA, NY 14853ROOM 240C RENOVATIONSDRAWING NAME:DRAWING NO:BAKER LABORATORY259 EAST AVEITHACA, NEW YORK 14850KEYPLANNTSNMPSSWITCH, TOGGLE, 20 AMP, 120/277 VAC, SINGLE CIRCUIT a - INDICATES SWITCHING DESIGNATIONWG-WIRE GUARDLUMINAIRE, TYPE INDICATED IN CAPITAL LETTERLOWER CASE LETTER INDICATES SWITCHING CIRCUITREFER TO LUMINAIRE KEYED NOTE FOR DESCRIPTIONSWITCH, TOGGLE, 20 AMP, 120/277 VAC, SINGLE CIRCUIT a - INDICATES SWITCHING DESIGNATIONWGLIGHTINGXXP2D2/10PHONE/DATA/COMMUNICATIONPOWERSYMBOL LISTFIRE ALARMXXxxCOMBINATION FIRE ALARM SPEAKER / STROBE UNIT,- STROBE CANDELLA INDICATEDABBREVIATIONSRECESSED LIGHT FIXTUREDUPLEX RECEPTACLERECEPTACLE MOUNTED ON SURFACE RACEWAYLIGHT SWITCHTELEPHONE/DATA JACKFIRE ALARM STROBE UNITOCCUPANCY SENSOR, CEILING MOUNTEDDEMOLITION LEGEND:SRXXGENERAL NOTES:1.THIS CONTRACTOR SHALL REMOVE ONLY EXISTING ELECTRIC ITEMS IN AREAS OF RENOVATIONS, UNLESSOTHERWISE NOTED, TO ACCOMMODATE THE NEW CONSTRUCTION. REROUTING OF EXISTING MAY BEREQUIRED AT NEW OPENINGS IN EXISTING CONSTRUCTION OR INTERFERENCE WITH OTHER NEW WORK, ASNOTED BELOW.2.DRAWINGS INDICATE SPECIFIC ITEMS TO BE REMOVED AND/OR RELOCATED IN ORDER TO INDICATEGENERAL SCOPE. WIRING & CIRCUITRY ARE NOT SHOWN BUT SHALL BE INCLUDED. THE ELECTRICALCONTRACTOR SHALL REMOVE, RELOCATE OR REROUTE ADDITIONAL ITEMS NOT INDICATED BUTNECESSARY FOR PROJECT RENOVATIONS. THEREFORE, THE ELECTRICAL CONTRACTOR SHALL ASSUMEWITHIN HIS BASE BID A NOMINAL AMOUNT OF UNKNOWN BRANCH CIRCUITS, FIXTURES, DEVICES ANDSYSTEMS WIRING WITHIN WALLS OR OPENINGS BEING REMOVED OR RELOCATIONS REQUIRED FOR NEWWORK.3.WHERE DEVICES, FIXTURES, ETC. ARE INDICATED TO BE REMOVED, THEY AND THEIR RELATEDWIRING/CONDUIT SHALL BE REMOVED BACK TO THE SOURCE PANELBOARD UNLESS NOTED OTHERWISE. IFCIRCUITS ARE FOUND THAT HAVE OTHER ITEMS ON THEM THAT ARE TO REMAIN, THESE CIRCUITS SHALLREMAIN. MAINTAIN CIRCUIT CONTINUITY TO FEED THRU TO ANY REMAINING DEVICES, FIXTURESEQUIPMENT, ETC. RELOCATE ANY CIRCUITS THAT ARE TO REMAIN, AS REQUIRED, TO AVOID CONFLICT WITHNEW CONSTRUCTION. PROPERLY TERMINATE ALL WIRING.4.MAINTAIN CIRCUIT CONTINUITY TO ALL EXISTING REMAINING ELECTRICAL SYSTEMS PASSING THRURENOVATED SPACES OR WHERE ONLY A PORTION OF A CIRCUIT IS REMOVED.5.REFER TO ARCHITECTURAL DEMOLITION DRAWINGS & NOTES FOR COORDINATION.6.VISIT THE SITE TO DETERMINE THE EXACT EXTENT OF ELECTRICAL DEMOLITION WORK REQUIRED TOCOMPLETE THE NEW CONSTRUCTION. EXISTING CONDITIONS ARE TAKEN FROM FIELD OBSERVATION. OTHERITEMS MAY EXIST.ELECTRICAL GENERAL REMOVAL NOTES:1.ELECTRICAL CONTRACTOR SHALL COORDINATE ALL ELECTRICAL DEVICE PLACEMENT AND ELEVATIONS WITHCASEWORK SUPPLIER AND ARCHITECT PRIOR TO ROUGH-IN. GENERAL CONTRACTOR SHALL PROVIDE ALL DRILLINGAND GROMMETING IN CASEWORK FOR CORD ACCESS IF REQUIRED.2.ALL PENETRATIONS THROUGH FIRE/SMOKE BARRIERS SHALL BE FIRESTOPPED IMMEDIATELY AFTER PENETRATION ISMADE. TEMPORARY FIRE STOPPING IS REQUIRED IF WORK IS NOT COMPLETE AT TIME OF PENETRATION.FIRESTOPPING MUST BE EQUAL IN RATING TO THE CONSTRUCTION OF THE MATERIAL PENETRATED.3. UNLESS NOTED OTHERWISE, THE MAXIMUM NUMBER OF HOME RUN CIRCUITS IN A CONDUIT SHALL BE 3. EACHCIRCUIT SHALL CONTAIN DEDICATED NEUTRAL AND GROUND CONDUCTORS.4. POWER AND LIGHTING CIRCUITS SHALL NOT BE INSTALLED IN THE SAME CONDUIT.5. LIGHTING FIXTURES SHALL NOT BE USED AS RACEWAYS. ALL LIGHT FIXTURES SHALL BE CONNECTED TO AJUNCTION BOX WITH A LIGHT ),;785(7$37+$7'2(6127(;&(('·,1/(1*7+6.THE GROUND WIRES FOR THE LIGHTING AND POWER CIRCUITS SHALL BE BONDED TO ALL JUNCTION BOXESINSTALLED IN THE CONDUIT SYSTEM.7. ALL LIGHT FIXTURES SHALL BE BONDED TO THE GROUND WIRE.8. UNLESS NOTED OTHERWISE, ALL LIGHT SWITCH COVER PLATES AND RECEPTACLE COVER PLATES SHALL BESTAINLESS STEEL.9. ALL JUNCTION BOXES FOR POWER AND LIGHTING CONDUIT SYSTEMS LOCATED ABOVE CEILING SYSTEMS SHALLHAVE CIRCUIT DESIGNATIONS MARKED ON THE JUNCTION BOX COVER PLATES.10. PROVIDE NEW TYPEWRITTEN PANEL SCHEDULE AT THE PANELBOARDS AFTER THE ELECTRICAL LIGHTING ANDRECEPTACLE WORK IS COMPLETED. INCLUDE ON PANEL SCHEDULE INFORMATION FOR EXISTING BRANCH CIRCUITS.11. UNLESS NOTED OTHERWISE, ALL RECEPTACLE BRANCH CIRCUITS SHALL CONSIST OF 2 #12 AND 1 #12 GND ASSHOWN ON HOME RUN.12. REPAIR/PATCH TO MATCH ALL SURFACES (WALL, FLOORS, CEILINGS, PAVEMENT. WALKWAYS, ETC.) DISTURBED DUETO THIS WORK.13. COORDINATE INSTALLATION OF OCCUPANCY SENSORS WITH MANUFACTURERS RECOMMENDATIONS. MODIFYLOCATIONS SHOWN ON DRAWINGS AS REQUIRED.14. COORDINATE ALL ELECTRICAL WORK AND POWER OUTAGES WITH OWNER AND OTHER TRADES PRIOR TO START OF&216758&7,211232:(5287$*(66+$//2&&85:,7+2872:1(5·635,25.12:/('*(:,5($//6$)(7<6<67(0&20321(176,1&203/,$1&(:,7+7+(6$)(7<6<67(00$18)$&785(5·6 SPECIFICATIONS. 16. WHEREVER POSSIBLE REUSE EXISTING CONDUIT, RACEWAY AND BACK BOXES IF IN GOOD CONDITION.EXTEND/PROVIDE CONDUIT/RACEWAY AS REQUIRED FOR PROPER MOUNTING OF DEVICES. CONCEAL ABOVE CEILINGOR WITHIN WALL WHERE POSSIBLE.17.CONDUCTORS SHALL BE A MINIMUM 12 AWG, STRANDED COPPER, 600VAC, 90 DEGREES C, TYPE THHN/THWN FORDRY AREAS AND XHHW/THWN FOR WET AREAS.18.CONDUITS SHALL BE A MINIMUM OF 3/4" DIAMETER ELECTRICAL METALLIC TUBING (EMT). CONCEAL CIRCUITRYWHEREVER POSSIBLE. EXPOSED CIRCUITRY SHALL BE SURFACE MOUNT AND PAINTED TO MATCH WALL OR CEILINGSURFACE UNLESS NOTED OTHERWISE.19.AIC RATING OF NEW CIRCUIT BREAKERS SHALL MATCH RATING OF RESPECTIVE PANELBOARD. SIZE AS INDICATED.20.PROVIDE PULL STRING THROUGH NEW CONDUIT AND BOXES. PROVIDE SUPPORT HANGERS FOR CONDUIT AS NEEDED.21.SCHEDULE FIRE ALARM SHUT DOWNS THROUGH CUSTOMER SERVICE TO PREVENT NUISANCE ALARMS DURINGCONSTRUCTION.22.VERIFY AND COORDINATE EXACT FIRE ALARM DEVICE REQUIREMENTS WITH CORNELL ENVIRONMENTAL HEALTH ANDSAFETY DEPARTMENT AND EXISTING SIMPLEX 4120 FIRE ALARM SYSTEM LOCATED IN THE GROUND FLOOR SWSTAIRWELL PRIOR TO ORDERING.23.VERIFY AND COORDINATE EXACT TELECOMMUNICATIONS OUTLET REQUIREMENTS WITH CORNELL INFORMATIONTECHNOLOGY DEPARTMENT.ELECTRIC GENERAL NOTES:OUTLET LOCATIONS INDICATED.APPROXIMATE LOCATION OFEXISTING FIRE ALARM PANEL
acWGdA2cA2aA3bdB1EXISTING GE NLABELECTRIC PANEL P2D2,100A MLO, 208/120V, 3PHASE 4 WIREdB2EM314625676787CCCCCCCCCCCCCCGFCIGFCIGFCIGFCIEXISTING GE NLABELECTRIC PANEL P2D2,100A MLO, 208/120V, 3PHASE 4 WIRESR1112GFCI4TYPICAL3 P2D2/27 P2D2/29 P2D2/30 P2D2/33 P2D2/34 P2D2/35 P2D2/362224TYPICAL5555555+40" AFF+40" AFF+34" AFFGFCIGFCI6789151511111010+34" AFF P2D2/325 P2D2/3158EXISTING GE NLABELECTRIC PANEL P2D2,100A MLO, 208/120V, 3PHASE 4 WIRESR55466471TYPICAL224&23<5,*+7/$%(//$$662&,$7(6'3&ISSUED FOR:DATE:BID DOCUMENTSJUNE 23, 2014DESCRIPTIONNO.DATEDRAWN BY:APPROVED BY:214394EngineeringArchitectureEnvironmentalPlanningCORNELL UNIVERSITYPROJECT NO:REVISIONFACILITIES MANAGEMENT119 HUMPHREYS SERVICE BUILDINGITHACA, NY 14853ROOM 240C RENOVATIONSDRAWING NAME:DRAWING NO:BAKER LABORATORY259 EAST AVEITHACA, NEW YORK 14850KEYPLANNTSNMPSA-1011N1/4" = 1'-0"PARTIAL SECOND FLOOR DEMOLITION PLANA-10121/4" = 1'-0"PARTIAL SECOND FLOOR POWER RENOVATION PLANNA-10131/4" = 1'-0"PARTIAL SECOND FLOOR LIGHTING RENOVATION PLANNKEYED ELECTRICAL DEMOLITION NOTES:DISCONNECT AND REMOVE EXISTING RECESSED 3 LAMP PARABOLIC LIGHT FIXTURES.TAG EXISTING CIRCUIT FOR REUSE.DISCONNECT AND REMOVE EXISTING OCCUPANCY SENSOR. REMOVE ASSOCIATEDCIRCUITRY BACK TO SOURCE.REMOVE EXISTING LIGHT SWITCHES. SAVE BACK BOX FOR REUSE WITH NEW LIGHTSWITCH.DISCONNECT AND REMOVE EXISTING RECEPTACLE AND COVER PLATE. TAG EXISTINGCIRCUIT FOR REUSE.DISCONNECT AND REMOVE EXISTING RECEPTACLE, COVER PLATE AND ASSOCIATEDDEVICES. REMOVE WIRING BACK TO NEAREST JUNCTION BOX. MAINTAIN CIRCUITCONTINUITY TO DOWN STREAM DEVICES.DISCONNECT AND REMOVE EXISTING COMMUNICATIONS OUTLET AND ASSOCIATEDDEVICES. REMOVE CABLING BACK TO SOURCE.DISCONNECT AND REMOVE EXISTING FIRE ALARM NOTIFICATION DEVICE, ASSOCIATEDCONDUIT AND WIRING BACK TO NEAREST JUNCTION BOX. TAG FOR REUSE.1234567KEYED LIGHTING NOTES:PROVIDE NEW 3 LAMP RECESSED LINEAR FLUORESCENT TROFFER. MODIFY/EXTENDEXISTING LIGHTING CIRCUIT SAVED DURING DEMOLITION WITH (2)#12 AWG THHN CUCONDUCTOR AND (1)#12 CU THHN GROUND IN FLEXIBLE METAL CONDUIT ANDCONNECT. CIRCUIT TO LINE SIDE OF SWITCH INDICATED. LITHONIA2SP8-G-332-FW-RA125-MVOLT-GEB10PS-LP841.PROVIDE NEW 2 LAMP RECESSED LINEAR FLUORESCENT TROFFER. MODIFY/EXTENDEXISTING LIGHTING CIRCUIT SAVED DURING DEMOLITION WITH (2)#12 AWG THHN CUCONDUCTOR AND (1)#12 CU THHN GROUND IN FLEXIBLE METAL CONDUIT ANDCONNECT. CIRCUIT TO LINE SIDE OF SWITCH INDICATED. LITHONIA2SP8-G-332-FW-RA125-MVOLT-GEB10PS-LP841.PROVIDE NEW 2 LAMP RECESSED LINEAR FLUORESCENT TROFFER. CIRCUIT FROMNEAREST EMERGENCY LIGHTING CIRCUIT WITH (2)#12 AWG THHN CU CONDUCTORAND (1)#12 THHN CU GROUND IN 3/4" EMT CONDUIT. LITHONIA2SP8-G-232-FW-RA125-MVOLT-GEB10PS-LP841.PROVIDE WALL MOUNTED "ROOM IN USE" LIGHT. MODIFY/EXTEND EXISTING LIGHTINGCIRCUIT SAVED DURING DEMOLITION WITH (2)#12 AWG THHN CU CONDUCTOR AND(1)#12 CU THHN GROUND IN 3/4" EMT CONDUIT AND CONNECT. CIRCUIT FROMSWITCH INDICATED. LITHONIA LE-P-R-120/277-SW14.PROVIDE DARK ROOM LIGHT INDICATED WITH RED FILTER. MODIFY/EXTEND EXISTINGLIGHTING CIRCUIT SAVED DURING DEMOLITION WITH (2)#12 AWG THHN CUCONDUCTOR AND (1)#12 CU THHN GROUND IN 3/4" EMT CONDUIT AND CONNECT.CIRCUIT FROM SWITCH INDICATED. KENALL MEDMASTER MDRMG-1-120/277-1-TC.PROVIDE NEW 20A, 120/277V SPECIFICATION GRADE LIGHT SWITCH AND CIRCUIT TOCONTROL LIGHT FIXTURES AS INDICATED.PROVIDE LOW VOLTAGE DUAL TECHNOLOGY OCCUPANCY SENSOR AND POWER PACK.LOCATE AND CONNECT TO LIGHT FIXTURES PER MANUFACTURERSRECOMMENDATIONS. WATTSTOPPER DT300 & BZ-50.PROVIDE DOUBLE GANG LIGHT SWITCH WIRE GUARD. AMERICAN TIME INTEGRATEDSOLUTIONS G2371-W.12345678KEYED POWER & LOW VOLTAGE NOTES:PROVIDE NEW WHITE GFCI NEMA 5-20R RECEPTACLE AND COVER PLATE.MODIFY/EXTEND EXISTING CIRCUIT SAVED DURING CONSTRUCTION WITH (2)#12AWG THHN CU CONDUCTORS AND (1)#12 CU THHN GROUND AND CONNECT.PROVIDE WHITE DUAL CHANNEL SURFACE METAL RACEWAY WITH WIRING DEVICESAS INDICATED. LEGRAND WIREMOLD 4000 SERIES.PROVIDE VERTICAL WHITE DUAL CHANNEL SURFACE METAL RACEWAY IN CORNERSPACE BETWEEN SHELVING UNITS UP TO ABOVE CEILING FOR ELECTRICAL ANDCOMMUNICATIONS ACCESS. LEGRAND WIREMOLD 4000 SERIES.PROVIDE NEW WHITE NEMA 5-20R RECEPTACLE AND COVER PLATE IN DUALCHANNEL RACEWAY. CIRCUIT AS INDICATED WITH (2)#12 AWG THHN CUCONDUCTORS AND (1)#12 CU THHN GROUND.PROVIDE 120V, 20A CIRCUIT AND NEW 120V, 20A CIRCUIT BREAKER IN PANELINDICATED. MATCH EXISTING TYPES AND RATINGS.PROVIDE NEW CEILING MOUNTED FIRE ALARM AUDIO/VISUAL SIGNALING DEVICE(SIMILAR TO SIMPLEX 4906-9128) AND CIRCUIT FROM NEAREST FIRE ALARMNOTIFICATION CIRCUIT. MATCH EXISTING WIRING AND CONDUIT WITH A MINIMUM OF#14 AWG STRANDED THHN CU OR PER MANUFACTURERS RECOMMENDATIONS IN3/4" EMT CONDUIT. TEST FOR PROPER OPERATION.PROVIDE NEW WALL MOUNTED FIRE ALARM AUDIO/VISUAL SIGNALING DEVICE(SIMILAR TO SIMPLEX 4906-9127) AND CIRCUIT FROM NEAREST FIRE ALARMNOTIFICATION CIRCUIT. MATCH EXISTING WIRING AND CONDUIT WITH A MINIMUM OF#14 AWG STRANDED THHN CU OR PER MANUFACTURERS RECOMMENDATIONS IN3/4" EMT CONDUIT. MOUNT AT 80" AFF TO BOTTOM OF LENS. TEST FOR PROPEROPERATION.PROVIDE NEW PHOTOELECTRIC SMOKE SENSOR (SIMILAR TO SIMPLEX 4098-9714)AND CIRCUIT FROM NEAREST FIRE ALARM INITIATION CIRCUIT. MATCH EXISTINGWIRING AND CONDUIT WITH A MINIMUM OF #16 AWG STRANDED THHN CU OR PERMANUFACTURERS RECOMMENDATIONS IN 3/4" EMT CONDUIT . MOUNT A MINIMUMOF 36" AWAY FROM AIR SUPPLY DIFFUSER OR RETURN AIR OPENINGS. TEST FORPROPER OPERATION.PROVIDE NEW RATE OF RISE HEAT SENSOR (SIMILAR TO SIMPLEX 4098-9733) ANDCIRCUIT FROM NEAREST FIRE ALARM INITIATION CIRCUIT. MATCH EXISTING WIRINGAND CONDUIT WITH A MINIMUM OF #16 AWG STRANDED THHN CU OR PERMANUFACTURERS RECOMMENDATIONS IN 3/4" EMT CONDUIT. TEST FOR PROPEROPERATION.PROVIDE TELECOMMUNICATIONS OUTLET IN SURFACE MOUNTED RACEWAYCONSISTING OF 2-8 POSITION, 8 WIRE, T568A CATEGORY 6 MODULAR RJ45 JACKS(PANDUIT CJ688TG) AND SLOPED FACEPLATE (PANDUIT CBE SERIES). COORDINATEEXACT REQUIREMENTS AND OUTLET NUMBER CONFIGURATION FOR ROOM LAYOUTSWITH CORNELL INFORMATION TECHNOLOGY DEPARTMENT.12345678910APPROXIMATE LOCATION OFEXISTING FIRE ALARM PANEL