HomeMy WebLinkAbout_1437_112 Edgemoor Addendum No 1CORNELL UNIVERSITY 112 EDGEMOOR LANE
HUMPHREYS SERVICE BUILDING BATHROOM ALTERATIONS
ITHACA, NEW YORK 14853
ADDENDUM No. 1
April 16, 2015
This Addendum contains changes to the requirements of the Contract Documents and Specifications. Such changes are to be incorporated into the Construction Documents and shall apply
to the work with the same meaning and force as if they had been included in the original document. Wherever this Addendum modifies a portion of a paragraph of the specifications or
a portion of any Drawing, the remainder of the Paragraph or Drawing shall remain in force.
NOTE: Provisions of all Contract Documents apply.
PROJECT MANUAL
Section 01 23 00, ALTERNATES
Paragraph 1.3.A REPLACE First sentence in paragraph body
WITH “Refer to Drawing A110 and all scopes labeled “Alternate #1” in mechanical, electrical and plumbing drawings.”
Paragraph 1.3.B REPLACE First sentence in paragraph body
WITH “Refer to Drawing A110 and all scopes labeled “Alternate #1” in mechanical, electrical and plumbing drawings.”
Paragraph 1.3.C REPLACE Paragraph in its entirety
WITH The following.
C. ALTERNATE NO. 2 – DHW CIRC SYSTEM & EXISTING DW INSULATION
Refer to Drawing P001 and P100. Provide domestic hot water circulation system, including circulation pump, valves and piping. Provide insulation for existing domestic water lines in
the basement.
DRAWINGS
Drawing No. A100, BASEMENT PLAN, BUILDING SECTION
Key Notes ADD Additional Key Notes on attached Drawing No. AD1.
Detail 12A REPLACE Detail in its entirety
WITH Detail 12A on attached Drawing No. AD1.
Detail 12D ADD note: REFER TO HAND DRYER CIRCUIT REMOVAL NOTE ON DWG E100. PATCH AND PAINT ABANDONED OPENING AT EXTERIOR CONDUIT REMOVAL TO MATCH EXISTING ADJACENT SURFACES.
Drawing No. A101, FIRST FLOOR
Key Note F1 REPLACE Key note in its entirety
WITH The following.
FRAMING MODIFICATIONS TO INSTALL WOOD COLUMN
A. OPEN EXIST EXT AND INT WALLS AT INTERSECTION AS REQ’D.
B. INSTALL (4) 2x4 STUDS IN EXT WALL PLANE AS REQ’D TO CREATE SOLID WOOD COLUMN DIRECTLY UNDER ENDS OF BEAMS TO BE INSTALLED ON UPPER FLOORS.
1. REFER TO DWG 12D/A100 FOR BEAM LOCATIONS.
2. INSTALL STUDS AROUND ANY EXIST STUD(S) DISCOVERED UNDER BEAM ENDS.
C. REMOVE AND REINSTALL UP TO TWO EXIST STUDS AT END OF INT WALL FRAMING AS REQ’D TO ACCESS EXT WALL FRAMING.
D. PATCH AND PAINT FINISHES IN LAUNDRY RM 108 TO MATCH EXISTING. REFER TO DWG AD2.
Detail 12A ADD note: REMOVE EXISTING HAND DRYER.
Detail 12D ADD note: REFER TO HAND DRYER CIRCUIT REMOVAL NOTE ON DWG E100. PATCH AND PAINT ABANDONED OPENING AT EXTERIOR CONDUIT REMOVAL TO MATCH EXISTING ADJACENT SURFACES.
Drawing No. A102, SECOND FLOOR
Key Note F1a REPLACE Key note in its entirety
WITH The following.
FRAMING MODIFICATIONS TO INSTALL WOOD COLUMN
A. OPEN EXIST EXT WALL AS REQ’D.
B. INSTALL (4) 2x4 STUDS IN EXT WALL PLANE AS REQ’D TO CREATE SOLID WOOD COLUMN DIRECTLY UNDER ENDS OF BEAM TO BE INSTALLED ABOVE.
1. REFER TO DWGS 12D/A100 AND 12G/A102 FOR BEAM LOCATION.
2. INSTALL STUDS AROUND ANY EXIST STUD(S) DISCOVERED UNDER BEAM ENDS.
Detail 12A ADD note: REMOVE EXISTING HAND DRYER.
Detail 12D ADD note: REFER TO HAND DRYER CIRCUIT REMOVAL NOTE ON DWG E100. PATCH AND PAINT ABANDONED OPENING AT EXTERIOR CONDUIT REMOVAL TO MATCH EXISTING ADJACENT SURFACES.
Drawing No. A103, THIRD FLOOR
Key Note F1a REPLACE Key note in its entirety
WITH The following.
FRAMING MODIFICATIONS TO INSTALL WOOD COLUMN
A. OPEN EXIST EXT WALL AS REQ’D.
B. INSTALL (4) 2x4 STUDS IN EXT WALL PLANE AS REQ’D TO CREATE SOLID WOOD COLUMN DIRECTLY UNDER ENDS OF BEAM TO BE INSTALLED ABOVE.
1. REFER TO DWGS 12D/A100 AND 12G/A102 FOR BEAM LOCATION.
2. INSTALL STUDS AROUND ANY EXIST STUD(S) DISCOVERED UNDER BEAM ENDS.
Detail 12A ADD note: REMOVE EXISTING HAND DRYER.
Detail 12D ADD note: REFER TO HAND DRYER CIRCUIT REMOVAL NOTE ON DWG E100. PATCH AND PAINT ABANDONED OPENING AT EXTERIOR CONDUIT REMOVAL TO MATCH EXISTING ADJACENT SURFACES.
Drawing No. M001, MECHANICAL NOTES AND SCHEDULES
General Notes DELETE Note No. 5 regarding asbestos abatement in its entirety.
Drawing No. E100, ELECTRICAL REMOVAL PLAN
Entire Drawing ADD note:
HAND DRYER CIRCUIT REMOVAL
ELECTRICAL CONTRACTOR SHALL VERIFY ROUTING OF EXISTING CONDUIT FEEDING HAND DRYERS TO BE REMOVED. IT IS BELIEVED THAT A PORTION OF THE CIRCUIT IS RUN ON THE BUILDING EXTERIOR. EXISTING
CONDUIT SHALL BE REMOVED.
Detail 1/E100 ADD note to junction box for Fire Alarm Notification Device in corridor outside Bathroom 100TA: REFER TO DWG A101. REMOVE AND RELOCATE OR REINSTALL JUNCTION BOX AND CONDUIT
AS REQUIRED FOR DOOR RELOCATION.
Drawing No.AD2, EXIST FINISHES/LAUNDRY ROOM 108
ADD attached drawing.
Drawing No. AD3, ROOM 206 WEST WALL
ADD attached drawing.
Drawing No. AD4, ROOM 306 WEST WALL
ADD attached drawing.
RESPONSES TO BIDDERS’ REQUESTS FOR INFORMATION
Refer to attached Table 1.
ATTACHMENTS
Drawing No. AD1 BASEMENT RCP REVISION WITH
ADDITIONAL DWG A100 KEY NOTES 1 page
Drawing No. AD2 EXIST FINISHES/LAUNDRY ROOM 108 1 page
Drawing No. AD3 ROOM 206 WEST WALL 1 page
Drawing No. AD4 ROOM 306 WEST WALL 1 page
Table 1 RESPONSES TO BIDDERS’ REQUESTS
FOR INFORMATION 1 page
****END OF ADDENDUM****