Loading...
HomeMy WebLinkAboutDay Hall6 5 4 Cornell University Ithaca. New York Facilities Engineering Civil, Structural, Architecture, Mechanical Electrical, Environmental & Energy Engineering Hump ireys Service Building; Ithaca, N.Y. PROJECT SCOPE 12 The purpose of this project is to make improvements to room 305 and suite 300J in Day Hall. Work includes special modifications to room 305, replacement of finishes and modification of lighting and mechanical components to support the architectural changes. Changes in suite 300J include demolition and reconstruction of a new kitchenette with minor space modifications and electrical changes to support those changes. Installation of new finishes, casework, equipment and furniture are included in the scope of work. Additional enabling work on the second and first floor is included in this project. 6 5 14 13 12 11 10 9 In's a on oom DRAWING LIST T-001 G-001 TITLE SHEET CODE REVIEW SU ARY ARCHITECTURE A-000 A-100 A-101 A-102 A-300 A-301 MECHANICAL MP -000 M-100 P-100 ELECTRICAL E-000 ED -101 E-101 E-102 8 7 6 4 2 rove ARCHITECTURAL SCOPE OF WORK, PATTERNS, SYMBOLS, DETAI S AND SCHEDULES 300 SUITE PLANS - DEMOLITION, NEW WORK, RCP, FINISHES 305 ROOM PLANS - DEMOLITION, NEW WORK, RCP, FINISHES PARTIAL SECOND FLOOR PLANS - DEMOLITION AND NEW WORK ELEVATIONS ELEVATIONS AND SECTIONS PIPING STANDARDS, SPECIFICATIONS AND EQUIPMENT SCHEDULE PARTIAL THIRD FLOOR MECHANICAL PLANS AND SCHEDULES PLUMBING CONSTRUCTION PLANS ELECTRICAL SCOPE OF WORK, GENERAL NOTES, SUBMITTAL SCHEDULE, SYMBOLOGY AND ABBREVIATIONS PARTIAL THIRD FLOOR ELECTRICAL DEMOLITION PLAN PARTIAL THIRD FLOOR POWER & PHONE/DATA PLAN PARTIAL THIRD FLOOR LIGHTING & FIRE ALARM PLAN 10 9 7 6 5 LOCATION PLAN - DAY HALL, THIRD FLOOR 4 2 WARNING: IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT HIS SEAL AND THE NOTATION "ALTERED BY' FOLLOWED BY HIS SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. AP ►VA DATE: ACILITIES ENGINEERING E RONMENTAL HEALTH AND SAF ARC CIVIL: ELEC. MECH: REVISIONS: DATE= 06/05/13 - ISSUE FOR CONSTRUCTION 0 611 1111146016 ea 431 DATE: FACILITY: 2026 DESIGN: FE DESIGN DRAWN: ebbN June 05, 2013 TIT E SHEET T-001 P0356 221-1-135 A N 6 15 14 2 1 ARNING: IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT HIS SEAL AND THE NOTATION "ALTERED BY FOLLOWED BY HIS SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION, APP * AL: „ DATE: A FAGU ES ENGINEERING ENVIRON TAL HEALTH AND SAFETY ARCH: CM.; ELEC- MECH- B ii A , . " ,.. , r. ., r , 11 :::11111! n ,n i t 1,,.', .; ..i .. TOTAL TRAVEL TOTAL TRAVEL ;144:11; ' ..., ......._....... r—DISTANCE: 66 FT DIST: 105 FT . , ,tE „ Pi 0 CODE REVIEW SUMMARY 0 co DING CODE DATA EGRESS P N 6 15 14 2 10 9 8 7 6 5 4 2 BUILDING CODE DATA: Day Hall #2026 APPLICABLE CODES: BUILDING CODE OF NY STATE, 2010 (BCNYS) FIRE CODE OF NY STATE, 2010 (FCNYS) EXISTING BULDING CODE OF NY STATE, 2010 (EBCNYS) BUILDING AFFILIATION: NY STATE or ENDOWED USE AND OCCUPANCY CLASSIFICATIONS (CHAPTER 3): USE(S)- BUSINESS CLASSIFICATION(S) B A *NO CHANGE IN USE OR OCCUPANCY FOR THIS PROJECT. C1ASSIFCATION OF WORK (EBCNYS CHAPTER 4): LEVEL 2 ALTERATION HEIGHT AND AREA LIMITATIONS (BCNYS CHAPTER 5): EXISTING COMPLIES WITH TABLE 503 TYPE OF CONSTRUCTION (BCNYS CHAPTER Al (EXISTING) FIRE PROTECTION SYSTEMS (FCNYS CHAPTER 9) REQUIRED PROVIDED AUTOMATIC SPRINKLER SYSTEMS MIIIIIIMIIIMI N Y FIRE ALARM & MANUAL MIIIIIIMMIIII DETECTION SYSTEMS AUTOMATIC (SECTION 9072) vo IC DALARM VISUAL ALARM NOTIFICATION (SECTION 907.10) NS OF EGRESS (BCNYS CHAPTER 10) MEANS PROPOSED OCCUPANT LOAD 20 --' ALLOWABLE OCCUPANT LOAD 1 OOSFOCCUPANT FOR BUSINESS OCCUPANCY 15 SF/ OCCUPANTY ASSEMBLY NUMBER PER AREA ALLOWANCE (TABLE 10 . . B Occupancy ROOM USE SF OCCUPANTS 302 workroom 216 2 kitchenette/ copy 164 1 11111MIMMIIIIIIIIIMIll 305 meethg 524 5 IIIEIIIIII IIIIIIIIIIIIIIIIIIIIII TOTAL 11.111.11111111111.11111.11111.. EGRESS WIDTH (TABLE 1005.1) REQUIRED PROVIDED STAIRWAYS IIMMMMIIIIIIIIIII 0,3" PER OCCUPANT EXISTING EXCEEDS OTHER COMPONENTS 1111==..111111111..1 0.2" PER OCCUPANT EXISTING EXCEEDS REQUIRED PROVIDED EMERGENCY L1GHTING ( 006.1)MIIIIIIIIMMIMMMIMIMMIMMIIIMII.MIIINIIIIIII SIGNS ( . ) 11111.11.11MZEIIIIIMI TRAVEL DISTANCE 6. 1111111111111111.1.1111 < 200' 105' CORRIDOR FIRE RATED (TABLE 1017.1) 1111.111111111111 not present in existing not changed as part of renovation DEAD END (1017.3) <50 <50' EXITS PER STORY (1019.1) EXIT IT SEPARATION ( ASSEMBLY SPACES) 1=11111.1111111111111= ACCESSIBILITY 1111111111M PROVIDED Y / N COMPLIANCE KITCHENETTES 11=11111.1111111111111M Y Side Approach (606,2 exemption 1) PATH OF TRAVEL IIIIIIIIIIIIIIIIIIIMIIIIII.1 COMPLIANT ii A , . " ,.. , r. ., r , 11 :::11111! n ,n i t 1,,.', .; ..i .. TOTAL TRAVEL TOTAL TRAVEL ;144:11; ' ..., ......._....... r—DISTANCE: 66 FT DIST: 105 FT . , ,tE „ Pi 0 CODE REVIEW SUMMARY 0 co DING CODE DATA EGRESS P N 6 15 14 2 10 9 8 7 6 5 4 2 16 15 14 13 12 11 10 9 8 7 6 D ON MATERIAL SCHEDULE/ SHOP DWGS. PRODUCT DATA SAMPLES INSPECTIONS & TESTS O&MI DATA WARRANTIES GENERAL 035300 CONCRETE TOPPING Y Y 072100 SOUND BATT INSULATION Y 078413 PENETRATION FIRESTOPPING Y Y Y 08113 DECO RATIE GLASS GLAZING Y Y Y Y FINISHES 092216 NON-STRUCTURAL METAL FRAMING SYSTEMS Y 095123 ACOUSTICAL TLE CEILINGS & GRIDS Y Y Y 096513 RESILIENT BASE AND ACCESSORIES Y Y 096519 RESILIENT TLE FLOORING Y Y Y Y 095813 TILE CARPET Y Y Y Y 097713 STRETCHED FABRIC WALL SYSTEMS Y Y Y Y 099123 INTERIOR PAINTING Y Y Y SPECIALTIES 101100 VISUAL DISPLAY SURFACES Y Y Y Y Y FURNISHINGS 122413 ROLLER WINDOW SHADES Y Y Y Y Y 123640 COUNTERTOPS (STONE SILL & PLAr9 COUNTERTOPS) Y Y Y j Y SUBMITTAL SCHEDULE 3 5/8" MTL STUDS WITH (1) LAYER 5/8" GWB EACH SIDE AND ACOUSTICAL BATT INSULATION • FOR RATED PARTITIONS, USE TYPE X GWB Q 3 5/8" MTL STUDS WITH (1) LAYER 5/8" GWB ONE SIDE AND ACOUSTICAL BATT INSULATION. Di AT COLUMNS IN 305 STUD BACK UP VARRIES IN DEPTH. NORTH FACE TO MATCH DEPTH OF EXISITNG TO REMAIN THERMOSTAT AND HVAC BOXES WALL PES SCALE: NONE NOT USED 5 4 SUMMON 1.5110M691 1010011.1. MUM= SOMME. DOOR - EXISTING TO REMAIN ITEM FOR DEMOLITION 22 KEYNOTE - DEMOLITION 99 KEYNOTE - NEW WORK F1 TAG - FINISH TAG - EQUIPMENT O TAG - CASEWORK 011 TAG - DOOR O TAG - FURNISHING BREAK LINE ELEVATION MARKER INTERIOR ELEVATION D16 A103 N 999 NORTH ARROW ROOM DATA SECTION 16 15 14 13 12 10 9 8 7 SYMBO B.O. BOTTOM OF BYND BEYOND CLG CEILING DTL DETAIL GWB GYPSUM WALL BOARD MTL METAL O.C. ON CENTER PTD PAINTED RCP REFLECTED CEILING PLAN SIM SIMILAR THK THICK T.O. TOP OF TYP TYPICAL U.N.O. UNLESS NOTED OTHERWISE U/S UNDERSIDE V.I.F. VERIFY IN FIELD ABBREVIATIONS WALL - EXISTING TO BE REMOVED WALL - EXISTING TO REMAIN WALL - NEW GWB STUD ARCHITECTU PATTERNS 6 5 4 2 ARCHITECTURAL SCOPE OF WORK: 1.0 THE PURPOSE OF THIS PROJECT IS TO MAKE IMPROVEMENTS TO ROOM 305 AND SUITE 300J IN DAY HALL. WORK INCLUDES SPACIAL MODIFICATIONS TO ROOM 305, REPLACEMENT OF FINISHES AND MODIFICATION OF LIGHTING AND MECHANICAL COMPONENTS TO SUPPORT THE ARCHITECTURAL CHANGES. CHANGES IN SUITE 300J INCLUDE DEMOLITION AND RECONSTRUCTION OF A NEW KITCHENETTE WITH MINOR SPACIAL MODIFICATIONS AND ELECTRICAL CHANGES TO SUPPORT THOSE CHANGES. INSTALLATION OF NEW FINISHES, CASEWORK, EQUIPMENT AND FURNITURE ARE INCLUDED IN THE SCOPE OF WORK. ADDITIONAL ENABLING WORK ON THE FIRST AND SECOND FLOOR IS INCLUDED IN THIS PROJECT. SCOPE OF WORK ARCHITECTURAL GENERAL NOTES: .0 DESIGN, CONSTRUCTION AND SAFETY SHALL CONFORM TO ALL LOCAL, STATE AND OWNER SPECIFIC CODES, INCLUDING (BUT NOT LIMITED TO) THE "NEW YORK STATE UNIFORM FIRE PROTECTION AND BUILDING CODE", LATEST REVISION, THE NFPA 101 LIFE SAFETY CODE, LATEST REVISION, ANSI A117.1 - LATEST REVISION, OSHA, AND ANY OTHER CODES GOVERNED BY THE JURISDICTION IN WHICH THIS PROJECT IS BEING CONSTRUCTED. 2.0 THIS CONTRACT REQUIRES COMPLETE, FINISHED WORKABLE PROJECT OF THE AREAS INDICATED BY THE CONTRACT DOCUMENTS, AND SHALL INCLUDE ALL MATERIALS AND LABOR NECESSARY TO COMPLETE, REGARDLESS OF WHETHER OR NOT ALL WORK OR EACH ITEM IS SPECIFICALLY INDICATED ON ANY OTHER PORTION OF THE DRAWINGS AND / OR NOTES. 3.0 WHERE MATERIALS REFERENCED ON DRAWINGS, OR NECESSARY TO COMPLETE THE WORK OF THIS CONTRACT ARE NOT SPECIFIED HEREIN, PROVIDE BEST QUALITY MATERIALS. WHERE MATERIALS ARE INTENDED TO MATCH EXISTING, PROVIDE CLOSEST POSSIBLE MATCH, SUBJECT TO OWNER'S APPROVAL. ALL ITEMS AND WORK ON DRAWINGS ARE NEW, UNLESS INDICATED EXISTING. ALL WORK WHICH HAS BEEN DAMAGED SHALL BE REPAIRED OR REPLACED AT NO COST TO THE OWNER. WHERE ITEMS CAN NOT BE REPAIRED TO A "NEW CONDITION", OR WHERE THE STRUCTURAL INTEGRITY HAS BEEN AFFECTED, ITEMS SHALL BE REPLACED AT NO COST TO THE OWNER. 4.0 CONTRACTOR IS RESPONSIBLE TO VERIFY ALL SITE, FIELD AND BUILDING CONDITIONS PRIOR TO SUBMITTING BIDS AND COMMENCING WORK. IF THERE ARE ANY DISCREPANCIES BETWEEN DRAWINGS AND FIELD CONDITIONS, NOTIFY THE PROJECT MANAGER, WHO WILL REQUEST CLARIFICATION FROM THE ARCHITECT/ENGINEER AND PROVIDE CLARIFICATION IN WRITING. 5.0 WHERE EXISTING CONSTRUCTION OR ITEMS HAVE BEEN INFILLED, REMOVED AND / OR DISTURBED FOR INSTALLATION OF NEW WORK, CAUSING THE EXPOSURE OF UNFINISHED AND/OR DAMAGED SURFACES RESULTING SURFACES AND INFILLED SURFACES SHALL BE RECONSTRUCTED WITH MATERIALS TO MATCH FINISHED AREAS. ALL ABANDONED OPENINGS (Le. DUCT/PIPE REMOVALS, ETC.) AT WALLS, ROOF OR FLOOR TO BE INFILLED SOLID. 6.0 WORK IS REQUIRED IN VARIOUS PORTIONS OF THE FACILITY TO EXECUTE WORK OF OTHER TRADES (i.e. ELECTRICAL, MECHANICAL). ALTHOUGH NOT NECESSARILY SHOWN ON DRAWINGS, WORK IS REQUIRED IN THESE AREAS CONSISTING OF REMOVAL / REPLACEMENT OF CEILINGS, WALLS, FINISHES, PAVEMENT AND OTHER CONSTRUCTION AS NECESSARY TO PERFORM WORK AND RESTORE THESE SPACES OR AREAS TO ORIGINAL CONDITION. 7.0 GENERAL CONTRACTOR IS TO COORDINATE WORK OF ALL TRADES. SCHEDULE WORK PROGRESS THROUGHOUT THE ENTIRE PROJECT TO PREVENT CONFLICTS AND INTERFERENCES. OBTAIN ALL NECESSARY INFORMATION SUCH AS SIZES, LOCATIONS, TEMPLATES, LAYOUT, DIMENSIONS AND ALL OTHER INFORMATION NECESSARY FOR A PROPER AND WELL COORDINATED INSTALLATION. PRIOR TO INSTALLATION OF ITEMS, VERIFY AND CONFIRM WITH EACH CONTRACTOR EXACT LOCATION OF ALL ITEMS. 8.0 ALL PENETRATIONS (EXISTING OR NEW )THROUGH FLOORS AND FULL HEIGHT WALLS - IN AREA OF WORK TO BE FIRE STOPPED. ALL GAPS AND JOINTS AT RATED FLOORS, ROOFS AND WALLS TO BE FIRE & SMOKE STOPPED. GAPS AND JOINTS INCLUDE (BUT ARE NOT LIMITED TO) TOP OF WALL TO FLOOR OR ROOF DECK, WALL TO BEAMS, AND CONTROL OR EXPANSION JOINTS. FIRE STOPPING INCLUDES BOTH FORM OR PACKING MATERIAL AND THE FILL, VOID OR CAVITY MATERIAL. 9.0 JOBSITE WILL BE CLEANED DAILY AND DEBRIS REMOVED TO CONTAINERS OR TO VEHICLE WHICH WILL REMOVE DEBRIS FROM CAMPUS. CONTAINERS WILL BE REMOVED AS SOON AS FULL OR WHEN THE PROJECT HAS PROGRESSED TO A POINT THAT A CONTAINER IS NO LONGER REQUIRED. 10.0 CONTRACTOR IS RESPONSIBLE FOR PROTECTING ALL AREAS USED TO BRING SUPPLIES AND EQUIPMENT INTO THE PROJECT AREA. ANY DAMAGE TO AREAS OUTSIDE THE PROJECT AREA INCLUDING BUT NOT LIMITED TO THE LOBBY AND CORRIDOR SHALL BE REPAIRED AT NO COST TO THE OWNER. NOTES 2 WARNING: IT ISA VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT HIS SEAL AND THE NOTATION "ALTERED BY- FOLLOWED BY HIS SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. APP. _ L: FAC ' FTIES EN G EE DATE: ENVIRONMENTAL HEALTH AND SAFETY ARC CIVIL* ELEC. MECH. REVISIONS: DATE: 06/05/13 - ISSUE FOR CONSTRUCTION DESIGN: FE DESIGN D WN: jebb ARCHITECTURAL SCOPE OF WORK, PATTERNS, SYMBOLS, DETAILS AND SCHEDULES ZZ A-000 P0356 37 2 16 15 14 12 11 10 9 8 7 P4 NEW SOFFIT 6 EXISTING SOFFIT P4 p4 EXISTING SOFFIT 300H OFFICE 302 WORK ROOM EXISTING SOFFIT P4 11 300J 5 KITCHENETTE 0 2 302A OFFICE 302B SCALE: 1/4"=V-0" OFFICE 4 PARTIA THIRD FLOOR FINISHES P N SCALE: 1/4" = 1'-0" 2 PARTIAL THIRD FLOOR REFLECTED CEI ING P N SCALE: /4" =11-0" UP EDGE OF -FLOOR REMOVAL g 1 EDGE OF FLOOR REMOVAL 300H OFFICE 302 WORK ROOM 302A OFFICE 302B OFFICE 00 KITCHENETTE 2 SCALE: 1/4"=1-0" PART A THIRD FLOOR DEMOLITION P SCALE: 1/4" = PARTIAL THIRD FLOOR CONSTRUCTION PLAN CALE: /4" =1-0" 3 GENERAL NOTES: 2 .0 PROTECT EXISTING FINISHES AND EQUIPMENT TO REMAIN. 2.0 ASBESTOS CONTAINING MATERIALS (ACM) WILL BE MANAGED BY OWNER INCLUDING TESTING AND ABATEMENT UNDER SEPARATE CONTRACTS. IF CONTRACTORS UNCOVER OR SUSPECT ASBESTOS CONTAINING MATERIALS THEY ARE TO STOP WORK AND NOTIFY OWNER. 0 CONTRACTOR TO PROVIDE 3' X 3' PAINT COLOR IN FINAL LIGHTING CONDITIONS FOR APPROVAL. KEYED DEMOLITION NOTES: Q REMOVE EXISTING BUILT IN CASEWORK AND DISPOSE • REMOVE EXISTING KITCHENETTE CABINETS AND DISPOSE • REMOVE EXISTING REFRIGERATOR AND DISPOSE • REMOVE EXISTING CABINET SUPPORTS, FASTENERS AND DAMAGED SHEET ROCK. QREMOVE EXISTING FLOORING. 0 REMOVE EXISTING BASE. 0 REMOVE EXISTING FURNITURE AS REQUIRED TO PAINT WALLS COMPLETE. STORE, PROTECT AND REINSTALL AS PART OF WORK FOR THIS ROOM. KEYED CONSTRUCTION NOTES: PATCH AND REPAIR EXISTING CONCRETE FLOOR AS REQUIRED. LEVEL SLAB WITH ARDEX LU -100 SELF -LEVELING UNDERLAYMENT PRIOR TO INSTALLATION OF FLOOR FINISHES. CONSTRUCT FULL HEIGHT PARTITION. PATCH AND PREP ALL EXISTING WALLS FOR NEW FINISHES INSTALL BASE CABINETS, WALL CABINETS AND COUNTERTOP, SEE A-300 INSTALL NEW SINK AND FIXTURES, SEE PLUMBING DRAWINGS SOFFIT ABOVE, SEE REFLECTED CEILING PLAN AND ELEVATIONS AT EXISTING FIN TUBE COVER AND SMALL TUBULAR COMPONENT AT FLOOR PAINT TO TCH WALL AND PAINT TO MATCH BASE IN MANNER SIMILAR TO EXISTING. Q AT EXISTING FIN TUBE COVER PAINT ENTIRE ASSEMBLY TO MATCH WALL COLOR. FIXTURES, FURNITURE & EQUIPMENT: • NEW REFRIGERATOR PROVIDED BY CASEWORK VENDOR GE SSOKCX 20.2CF BOTTOM FREEZER QNEW OVERHEAD MICROWAVE PROVIDED BY CASEWORK VENDOR INSTALLED BY THIS CONTRACT. GE PEM31SM PROFILE SERIES UNDERCABINET MOUNT MICROWAVE CI NEW KRAFTMAID CABINETRY AS SHOWN ON DRAWING A-300. PRE -PURCHASED BY OWNER, INSTALLED AS PART OF THIS CONTRACT. P -LAM COUNTERTOPS AS PART OF THIS CONTRACT. WILSONART HD CRYSTALLINE DUNE 1838K-45 WITH CRESCENT PROFILE. ARCHITECTURAL FINISHES: BASE 0 JOHNSONITE MILLWORK REVEAL PROFILE RUBBER WALL BASE, COLOR 31 ZEPHYR CB B2 JOHNSONITE MILLWORK INFLECTION PROFILE RUBBER WALL BASE, COLOR # 150 WETLANDS FLOORING 0 INTERFACE CARPET TILES VECTOR, COLOR SAGE INSTALLED IN RUNNING PATTERN. F2 JOHNSONITE COLOR ESSENCE VINYL ENHANCE TILE. COLOR PRETTY PUTTY CE 127 0 AT TRANSITION BETWEEN EXISTING CARPET AND NEW VET PROVIDE JOHNSONITE SLIMLINE TRANSITION SLT-XX-A IN COLOR TO MATCH BASE. #150 WETLANDS. F4 AT TRANSITION BETWEEN EXISTING CARPET AND NEW CARPET PROVIDE JOHNSONITE T MOULDING CD -XX IN BLACK PAINT GENERAL PAINT SPECIFICATIONS: FOR CMU AND GWB PARTITION WALLS: 1ST COAT: SW HARMONY LOW ODOR INTERIOR LATEX PRIMER 2ND COAT: SW DURATION HOME INTERIOR LATEX EGGSHELL 3RD COAT: SW DURATION HOME INTERIOR LATEX EGGSHELL CI PAINT WALLS SHERWIN WILLIAMS SW 7012 CREAMY P2 PAINT ACCENT WALL SHERWIN WILLIAMS SW 6866 HEARTTHROB - THREE COATS TOP COLOR P PAINT EXISTING PAINTED DOORS AND FRAMES AS FOLLOWS: CORRIDOR TO MATCH EXISTING. OFFICES 302A AND 302B FRAMES SW 7012 CREAMY P4 PAINT SOFFITS TO MATCH WALL COLOR SW 7012 CREAMY 0 PAINT WALL AT THIS AREA TO CORNER. COLOR SW 7012 CR MY WARNING: IT ISA VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE ` DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT HIS SEAL AND THE NOTATION , "ALTERED BY" FOLLOWED BY HIS SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. APP FA' ILI 'IES ENGIN -"ING ENVIRO: itENTAL H ter, H AND SAF ATE: 13 ARC CIVIL. ELEC: MECH• NOTES REVISIONS: DATE: 06/05/13 - ISSUE FOR CONSTRUCTION A 300 SUITE PLANS - DEMOLITION, NEW WORK, RCP, FINISHES A-100 P0356 16 15 14 12 11 0 9 8 7 6 2 2 - -I 5? cu 6 14 13 12 0 4. 4//i/ r..sir i4' CEILING ARMSTRONG KNIFE EDGE AXIOM TRIM WITH FACTORY MADE OUTSIDE CORNERS AND 9/16" SUPRAFINE XL GRID. ALL WHITE. WITH ULTIMA BEVELED TEGULAR 24x24 TILES. AT ALL CUT EDGES TILE TO BE PAINTED TO MATCH FACE COLOR. BEGIN KNIFE EDGE 4" FROM FACE OF WALL/SOFFIT. SOFFIT SOFFIT @ 8'-0" 305 CONFERENCE 524 SF PARTIALTHIRD FLOOR FINISHES P N SCALE: 1/4" = SCALE: 1/4"=V-0" 16 15 14 13 PARTIAL THIRD FLOOR DEMOLITION PLAN 12 11 SCALE: 1/4" = 1-0" PARTIA THIRD FLOOR REFLECTED CEILING P N 9'-0" CONFERENCE 524 SF GN HOLD BACK FROM DOOR FRAME 1/2 ". WRAP BASE BACK TO WALL INSTALL NEW DOOR STOP ALIGN SCALE: GENERAL NOTES: 1.0 PROTECT EXISTING FINISHES AND EQUIPMENT TO REMAIN. 2.0 ASBESTOS CONTAINING MATERIALS (ACM) WILL BE MANAGED BY OWNER INCLUDING TESTING AND ABATEMENT UNDER SEPARATE CONTRACTS. IF CONTRACTORS UNCOVER OR SUSPECT ASBESTOS CONTAINING MATERIALS THEY ARE TO STOP WORK AND NOTIFY OWNER. 0 CONTRACTOR TO PROVIDE 3' X 3' PAINT COLOR IN FINAL LIGHTING CONDITIONS FOR APPROVAL. KEYED DEMOLITION NOTES: OREMOVE EXISTING WALL ASSEMBLY COMPLETE • REMOVE EXISTING FLOORING AND BASE Q REMOVE EXISTING DOOR AND FRAME 0 REMOVE EXISTING DROP CEILING SYSTEM COMPLETE • REMOVE EXISTING BUILT IN CABINETS/ SHELVING, SUPPORTS, FASTENERS AND DAMAGED SHEETROCK f�6 REMOVE EXISTING GRILL- SAVE FOR RE -USE. REMOVE EXISTING PLASTIC LAMINATE SILL. O REMOVE EXISTING WINDOW TREATMENT COMPLETE INCLUDING CLEAT AT WALL 0 DEMO AT EXISTING WALL ASSEMBLY TO ALLOW FOR CONSTRUCTION OF NEW BLOCKING FOR CANTILEVERED COUNTER TOP BRACKETS. QREMOVE EXISTING PAINTED WINDOW AND STOPS IN EXISTING DOOR. PREPARE FOR REPLACEMENT WITH NEW GLAZING AND STOPS. KEYED CONSTRUCTION NOTES: Q PATCH AND REPAIR EXISTING CONCRETE FLOOR AS REQUIRED. LEVEL SLAB WITH ARDEX LU -100 SELF -LEVELING UNDERLAYMENT PRIOR TO INSTALLATION OF FLOOR FINISHES. • CONSTRUCT FULL HEIGHT INSULATED PARTITION WITH BLOCKING TO SUPPORT SURFACE APPLIED TACK, WOOD AND WHITEBOARD PANELS. Q PATCH AND PREP ALL EXISTING WALLS FOR NEW FINISHES. REMOVE ALL REMNANT FASTENERS PRIOR TO PATCH. Q SOFFIT ABOVE, SEE REFLECTED CEILING PLAN AND ELEVATIONS Q NEW BLACK HONED GRANITE WINDOW SILL/ SERVICE LEDGE. JOINED TO EXISTING STONE SILL, SUPPORTED WITH FEDERAL BRACE CARRIER COUNTER BRACKETS SET INTO EXISTING WALL SYSTEM ON NEW BLOCKING SUPPORTS. Q NEW SOFTWALLS W.SOFTWALLS.COM) TACKABLE STRETCHED FABRIC WALL SYSTEM 3/4" THICK WITH TACKABLE MINERAL BOARD CORE SQUARE EDGE PROFILE WITH FABRIC WRAPPED BANDING AT ALL EXPOSED EDGES. FABRIC AS PROVIDED BY OWNER. SEE FINISH NOTES FOR FABRIC SPECIFICATIONS 1/4" = 1'-0" Q WHITEWALL DRY ERASE MAGNETIC STEEL WALL BOARD PANELING W.MAGNATAG.COM) 3/4" THICK PANELS WITH SELF EDGE FINISH ALL SIDES. 4x8 PANELS INSTALLED WITH MANUFACTURERS RECOMMENDED MECHANICAL FASTENERS. Q PROVIDE NEW TEMPERED GLAZED PANEL WITH WOOD STOPS AT EXISTING OPENING. PAINT STOPS, DOOR AND FRAME TO MATCH EXISTING. 0 PRECISE LOCATION OF FLOOR BOX TO BE COORDINATED WITH ARCHITECT TO ALLOW FOR INTEGRATION INTO CONFERENCE TABLE BASE. 10 NEW LUMINAIRE. FIXTURES, FURNITURE & EQUIPMENT: • NEW WALL MOUNT MONITOR AND MOUNT PROVIDED BY AV VENDOR • NEW KRAFTMAID CABINETRY AS SHOWN ON DRAWING L.2.) • A-300 AND A-301. PRE -PURCHASED BY OWNER, INSTALLED AS PART OF THIS CONTRACT. NEW KRUG WOOD WALL PANELS PROVIDED BY FURNITURE VENDOR; • PRE -PURCHASED BY OWNER; INSTALLED AS PART OF THIS CONTRACT. NEW COAT HOOKS MOUNTED AT 48" AFF WITH SECOND SET MOUNTED AT 66" AFF. SOLID OAK WOOD BACKING WITH BOBRICK B-2116 HEAVY DUTY CLOTHES HOOKS. ARCHITECTURAL FINISHES: BASE 61 JOHNSONITE MILLWORK REVEAL PROFILE RUBBER WALL BASE, COLOR FROM PALETTE A, B, OR C - AS SELECTED BY ARCHITECT. FLOORING 0 INTERFACE CARPET TILES VECTOR IN SAGE. INSTALLED IN RUNNING PATTERN. 0 AT TRANSITION BETWEEN EXISTING CARPET AND NEW CARPET PROVIDE JOHNSONITE T MOULDING CD -XX IN BLACK PAINT P1 PAINT WALLS SHERWIN WILLIAMS SW 7012 CREAMY 0 PAINT EXISTING PAINTED DOORS AND FRAMES TO MATCH EXISTING CORRIDOR DOORS. P4 PAINT SOFFITS TO MATCH WALL COLOR SW 7012 CREAMY TRIMS / SURFACE TREATMENTS 0 SOFTWALLS FABRIC WRAPPED TACT PANELS - KNOLL TEXTILES GLISTEN #WC1071/1 CRYSTAL SUPPLIED BY OWNER. 0 MANUAL MECHOSYSTEM ROLLER WINDOW SHADE, SINGLE ROLL, EUROTWILL REVERSIBLE WEAVE 6000 SERIES (3% OPEN). MOUNT AT TOP OF WINDOW AT HEAD. COLOR 6006 SILVER BIRCH. 0 9 8 7 PARTIAL TH RD FLOOR CO\STRUCTION PLAN 6 SCALE: 1/4" = 1'-0" NOTES WARNING: IT ISA VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT HIS SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. DATE: ENVIRON ARCH CIVIL- ELEC- MECH- A REVISIONS: DATE: 06/05113 - ISSUE FOR CONSTRUCTION DATE: June 05, 2013 FACILITY: 2026 DESIGN: EBB DRAWN: ebb 305 ROOM PLANS - DEMOLITION, NEW WORK, RCP, FINISHES A-101 P0356 221 -361 C}5 sz- 0 v 6 5 14 13 12 1 11 1 10 8 7 6 5 4 3 1 2 GENERAL NOTES: 1.0 PROTECT EXISTING FINISHES AND EQUIPMENT TO REMAIN. 2.0 ASBESTOS CONTAINING MATERIALS (ACM) WILL BE MANAGED BY OWNER INCLUDING TESTING AND ABATEMENT UNDER SEPARATE CONTRACTS. IF CONTRACTORS UNCOVER OR SUSPECT ASBESTOS CONTAINING MATERIALS THEY ARE TO STOP WORK AND NOTIFY OWNER. KEYED DEMOLITION NOTES: REMOVE EXISTING RECEPTACLE. RETAIN FOR -INSTALLATION 0 REMOVE SWITCH RETAIN FOR RE -INSTALLATION 0 REMOVE SECTION OF CEILING AND GRID TO ACCOMMODATE NEW WALL INSTALLATION. RETAIN FOR REINSTALLATION. KEYED CONSTRUCTION NOTES: 0 WARNING: IT ISA VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT HIS SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. A APP DATE: F ' ILi=IES ENGINE -'I NG ENVIRONMENTAL HEALTH AND SAF ARC CIVIL. ELEC. MECH• CONSTRUCT NEW WALL TO DECK TO CONCEAL ALL PLUMBING LINES. MINIMIZE THICKNESS OF WALL AND SIZE OF BUILDOUTS. INSULATE WITH SOUND BATT INSULATION. INSTALL NEW BASE TO MATCH. FINISH PAINT TO MATCH EXISTING WALL COLOR. RECONSTRUCT AND RE -INSTALL CEILING SYSTEM. CUT PANELS TO FIT NEW OPENING- PAINT ALL CUT EDGES OF TILES TO MATCH FACE COLOR. RE -INSTALL SWITCH AND RECEPTACLE AS SHOWN. ARCHITECTURAL FINISHES: BASE REVISION DATE: 06/05/13 - ISSUE FOR CONSTRUCTION 0 JOHNSONITE BASE TO MATCH EXISTING. PAINT GENERAL PAINT SPECIFICATIONS: FOR CMU AND GWB PARTITION WALLS: 1ST COAT: SW HARMONY LOW ODOR INTERIOR LATEX PRIMER 2ND COAT: SW DURATION HOME INTERIOR LATEX EGGSHELL 3RD COAT: SW DURATION HOME INTERIOR LATEX EGGSHELL 0 PAINT WALLS SHERWIN WILLIAMS TO MATCH EXISTING COLOR. SCALE: 114"=1'-0" PARTIA SECOND FLOOR DEMOLITION PLAN SCALE: 1/4" = 1'-0" = Z CD RS © F NEW PLUMBING LINES EXTENDED INTO EXISTING CABINETS. CAPPED FOR FUTURE CONNECTIONS. -ALIGN TOP @ 18" AFF TOP @ 48" AFF OFFICE OFFICE DATE: FACILITY: DESIGN: D WN: une 05, 201 2026 EBB ebb PARTIAL SECOND FLOOR PLANS - DEMOLITION AND NEW WORK SCALE: 1/4"=1'-0" 6 4 1 12 NOT USED PARTIAL SECOND FLOOR CONSTRUCTION P N 10 9 8 7 6 SCALE: /4" = 1'-0" NOTES 5 2 A-102 P0356 6 5 14 2 G 6 CAN LIGHTS ABOVE r FILLER 2'-9" 2'-9" FILLER 10" 71/2" I 1" EXTENSION P. 2'-O" 3'-O" 2'-0" 5 SOFFIT 8'-6" SECTION AND E EVATION ROOM 00J NOOK ELEVATION 300J KITCHENETTE NORTH SCALE: /2" =1-0" SCALE: /2" = 1'-O" EXISTING COPIER 1'-6" 2'-3" 2'-3" ELEVATION 302 WORK ROOM IS AND 1'-6" Zo SCALE: 2" = 1'-0" 2 ELEVATION 300J COPY AREA SCALE: 1/2" =1-0" 1'-6" 2'-9" 1'-3" 1-0" SOFFIT 7'-11" 3'-O" 1'-6" FIN. FLOOR 0'-0" ELEVATION 300 KITCHENETTE WEST SCALE: 1/2" -0" 2'-0" 3/4 " 2'-O" 2'-O" 2'-O" 3/4 " FILLER 2'-6" 2'-O" 2'-0" 2'-O" 2'-O" 3/4 " FILLER 2'-6" FIN. CEILING 9'-2" SOFFIT 8'-2" FIN. FLOOR 0'-0" ELEVATION 302 WORK ROOM 16 14 13 12 11 10 9 8 7 5 SCALE: 1/2" = 1'-0" 4 GENERAL NOTES: 1.0 PROTECT EXISTING FINISHES TO REMAIN. KEYED CONSTRUCTION NOTES: Q INSTALL NEW CABINETS AS SHOWN. CABINETS PROVIDED BY OWNER. Q INSTALL P -LAM COUNTERTOP CRESCENT EDGE PROFILE 1-1/2" THICK. P -LAM WILSONART CRYSTALLINE DUNE 1838K-45. 4" BACKSPLASH AT KITCHENETTE WITH CASCADE EDGE PROFILE. Q LED UNDERCABINET LIGHTS BY ELECTRICIAN. SEE ELECTRICAL DRAWINGS. INSTALL FINISHED FILL PIECE AT VERTICAL TRANSITION. MATCHING LAMINATE ON ALL EXPOSED EDGES WITH CLEAR SEALANT AT JOINTS. FIXTURES, FURNITURE & EQUIPMENT: NEW REFRIGERATOR PROVIDED BY CASEWORK VENDOR GE SSOKCX 20.2CF BO 1 1 OM FREEZER NEW OVERHEAD MICROWAVE PROVIDED BY CASEWORK VENDOR INSTALLED BY THIS CONTRACT. GE PEM31SM PROFILE SERIES UNDERCABINET MOUNT MICROWAVE SEE ELECTRICAL FOR POWER REQUIREMENTS NEW KRAFTMAID CABINETRY AS SHOWN ON DRAWING A-300. PRE -PURCHASED BY OWNER, INSTALLED AS PART OF THIS CONTRACT. P -LAM COUNTERTOPS AS PART OF THIS CONTRACT. WILSONART HD CRYSTALLINE DUNE 1838K-45 WITH CRESCENT EDGE PROFILE. ARCHITECTURAL FINISHES: BASE 62 JOHNSONITE MILLWORK INFLECTION PROFILE RUBBER WALL BASE, COLOR 150 WETLANDS PAINT P1 PAINT WALLS SHERWIN WILLIAMS SW 7012 CREAMY P2 PAINT ACCENT WALL SHERWIN WILLIAMS SW 6866 HEAR HROB - THREE COATS TOP COLOR P4 PAINT SOFFITS TO MATCH WALL COLOR SW 7012 CREAMY NOTES WARNING: IT ISA VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED. THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT H15 SEAL AND THE NOTATION 'ALTERED BY" FOLLOWED BY HIS SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. APPR FAC :"I IES ENGINEERING ENVIRONME ARCH. CIVIL - DATE: HEALTH AND SAF ELEC: MECH- REVISIONS: DATE: 06/05/13 - ISSUE FOR CONSTRUCTION Cid E 0 0 O co E 0E CD >l 0 Q >- 2 z � CV as 0f_ • 4 0 ctU DATE: une 05, 2013 FACILITY: 2026 DESIGN: RUBEN D WN: s ELEVATIONS A A-300 P0356 2 2 - I-11 C7 1 1 1 1'-6" 2'-3" 2'-3" 1'_6" Zo SCALE: 2" = 1'-0" 2 ELEVATION 300J COPY AREA SCALE: 1/2" =1-0" 1'-6" 2'-9" 1'-3" 1-0" SOFFIT 7'-11" 3'-O" 1'-6" FIN. FLOOR 0'-0" ELEVATION 300 KITCHENETTE WEST SCALE: 1/2" -0" 2'-0" 3/4 " 2'-O" 2'-O" 2'-O" 3/4 " FILLER 2'-6" 2'-O" 2'-0" 2'-O" 2'-O" 3/4 " FILLER 2'-6" FIN. CEILING 9'-2" SOFFIT 8'-2" FIN. FLOOR 0'-0" ELEVATION 302 WORK ROOM 16 14 13 12 11 10 9 8 7 5 SCALE: 1/2" = 1'-0" 4 GENERAL NOTES: 1.0 PROTECT EXISTING FINISHES TO REMAIN. KEYED CONSTRUCTION NOTES: Q INSTALL NEW CABINETS AS SHOWN. CABINETS PROVIDED BY OWNER. Q INSTALL P -LAM COUNTERTOP CRESCENT EDGE PROFILE 1-1/2" THICK. P -LAM WILSONART CRYSTALLINE DUNE 1838K-45. 4" BACKSPLASH AT KITCHENETTE WITH CASCADE EDGE PROFILE. Q LED UNDERCABINET LIGHTS BY ELECTRICIAN. SEE ELECTRICAL DRAWINGS. INSTALL FINISHED FILL PIECE AT VERTICAL TRANSITION. MATCHING LAMINATE ON ALL EXPOSED EDGES WITH CLEAR SEALANT AT JOINTS. FIXTURES, FURNITURE & EQUIPMENT: NEW REFRIGERATOR PROVIDED BY CASEWORK VENDOR GE SSOKCX 20.2CF BO 1 1 OM FREEZER NEW OVERHEAD MICROWAVE PROVIDED BY CASEWORK VENDOR INSTALLED BY THIS CONTRACT. GE PEM31SM PROFILE SERIES UNDERCABINET MOUNT MICROWAVE SEE ELECTRICAL FOR POWER REQUIREMENTS NEW KRAFTMAID CABINETRY AS SHOWN ON DRAWING A-300. PRE -PURCHASED BY OWNER, INSTALLED AS PART OF THIS CONTRACT. P -LAM COUNTERTOPS AS PART OF THIS CONTRACT. WILSONART HD CRYSTALLINE DUNE 1838K-45 WITH CRESCENT EDGE PROFILE. ARCHITECTURAL FINISHES: BASE 62 JOHNSONITE MILLWORK INFLECTION PROFILE RUBBER WALL BASE, COLOR 150 WETLANDS PAINT P1 PAINT WALLS SHERWIN WILLIAMS SW 7012 CREAMY P2 PAINT ACCENT WALL SHERWIN WILLIAMS SW 6866 HEAR HROB - THREE COATS TOP COLOR P4 PAINT SOFFITS TO MATCH WALL COLOR SW 7012 CREAMY NOTES WARNING: IT ISA VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED. THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT H15 SEAL AND THE NOTATION 'ALTERED BY" FOLLOWED BY HIS SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. APPR FAC :"I IES ENGINEERING ENVIRONME ARCH. CIVIL - DATE: HEALTH AND SAF ELEC: MECH- REVISIONS: DATE: 06/05/13 - ISSUE FOR CONSTRUCTION Cid E 0 0 O co E 0E CD >l 0 Q >- 2 z � CV as 0f_ • 4 0 ctU DATE: une 05, 2013 FACILITY: 2026 DESIGN: RUBEN D WN: s ELEVATIONS A A-300 P0356 2 2 - I-11 C7 16 4 15 14 13 12 10 9 8 7 6 5 4 1'-11 1/8 " CAN LIGHTS ABOVE 1 DECK 9'-2" FIN. CEILING 8'-0" GENERAL NOTES: 1.0 PROTECT EXISTING FINISHES AND EQUIPMENT TO REMAIN. 2.0 ASBESTOS CONTAINING MATERIALS (ACM) WILL BE MANAGED BY OWNER INCLUDING TESTING AND ABATEMENT UNDER SEPARATE CONTRACTS. IF CONTRACTORS UNCOVER OR SUSPECT ASBESTOS CONTAINING MATERIALS THEY ARE TO STOP WORK AND NOTIFY OWNER. FINISHED CEILING 8'-0" I.0 CONTRACTOR TO PROVIDE 3' X 3' PAINT COLOR IN FINAL LIGHTING CONDITIONS FOR APPROVAL. ARNING: IT ISA VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY, IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT HIS SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. APP OVA DATE: A FA ERING KEYED CONSTRUCTION NOTES: 0 CABINETRY PROVIDED BY OWNER. CONTRACTOR TO INSTALL AS SHOWN 02 GLARO 200 SERIES SATIN ALUMINUM COAT HOOK STRIPS FULL WIDTH OF OPENING AT ELEVATIONS SHOWN. Q INSTALL GRIP LOCK ART TRACK (RT-TRAC-80) WHERE SHOWN. SEE 6/ A-301 FOR DETAIL. Q NEW BLACK HONED GRANITE WINDOW SILL/ SERVICE LEDGE. JOINED TO EXISTING STONE SILL, SUPPORTED WITH FEDERAL BRACE CARRIER COUNTERT BRACKETS SET INTO EXISTING WALL SYSTEM ON NEW BLOCKING SUPPORTS. FIN. FLOOR 0'-0" E: 1"=1'-0" SECTION SOUTH ELEVATION ROOM 305 SCALE: 1/2" = EQ EQ DECK dy 9,-2" 1" — . ■tet �►...1 teAi 6,a 41, MAWa.ats.' ,.•'.s.1►,.+.1►% 6. AkoAd 64 6&o. ' A*4 , s6, ..r Ss% #4 414 44 14' 44 Ss* Or * 4#* *** 1‘, 4 *08 ��`�►'1►�1. t�1��1�4�,��=r1����a�►'��1���►��'1���''i►���!r.��i''1i►'�►�'�►��'���i� FIN. CEILING o 8'-0" EXISTING WALL FIN. FLOOR 0'-0" 2'-0" 4'-0" 4'-O" 4'-0" 2._0" SCALE: 1"=1' -CI" MONITOR PROVIDED AND INSTALLED BY AV VENDOR ENVIRONMENSBL HEALTH AND SAFETY ARCH: " CIVIL: ELEC: MECH• REVISIONS: DATE: 06/05/13 - ISSUE FOR CONSTRUCTION INSTALL NEW SOFTWALLS .SOFTWALLS.COM)TACKABLE STRETCHED FABRIC WALL SYSTEM 3/4" THICK WITH TACKABLE MINERAL BOARD CORE SQUARE EDGE PROFILE WITH FABRIC WRAPPED BANDING AT ALL EXPOSED EDGES. FABRIC AS PROVIDED BY OWNER. SEE FINISH NOTES FOR FABRIC SPECIFICATIONS INSTALL WHITEWALL DRY ERASE MAGNETIC STEEL WALL BOARD PANELING (WWW.MAGNATAG.COM) 3/4" THICK PANELS WITH SELF EDGE FINISH ALL SIDES. 4x8 PANELS INSTALLED WITH MANUFACTURERS RECOMMENDED MECHANICAL FASTENERS. INSTALL WOOD WALL PANEL 1/4" ABOVE BASE AND 3/4" FROM WALL. INSTALL 2x4 WHERE GRIP LOCK ART TRACK WILL BE MOUNTED AND FINISH TO MATCH WALL PROVIDE BLOCKING TO SUPPORT THE GRIP LOCK ART TRACK PROVIDE BLOCKING TO SUPPORT THE WOODEN WALL PANEL AND MONITOR AS REQUIRED. 12 INSTALL 2x1 TO SUPPORT MOUNTING OF THE WOODEN WALL PANEL. KEEP 3/4" FROM EDGE OF WOODEN WALL PANEL ON ALL SIDES. EXPOSED SURFACE TO MATCH PANEL SPECIES & FINISH. 13 NEW TEMPERED GLAZED PANEL AT OPENING IN EXISITNG DOOR. PAINT STOPS TO MATCH DOOR. 14 ACCESS POINT FOR FLOOR CABLE SYSTEM FIXTURES, FURNITURE & EQUIPMENT: 0 WOODEN WALL PANEL BY FURNITURE VENDOR. INSTALLED AS PART OF THIS CONTRACT 0 0 0 SOFTWALLS FABRIC WRAPPED TACK PANELS - KNOLL TEXTILES GLISTEN #WC1071/1 CRYSTAL- FABRIC SUPPLIED BY OWNER. WHITEBOARD WALL PANEL. MONITOR BY AV VENDOR. NEW LIGHT STRIP (SEE ELECTRIC) TAPE MOUNTED TO CEILING TRIM SYSTEM. EAST ELEVATION ROOM SCALE: 1/2" = 1'-0" EQ 4'-0" 7'-O" 4'-0" EQ DECK 9'-2" ARCHITECTURAL FINISHES: BASE 61 JOHNSONITE MILLWORK REVEAL PROFILE RUBBER WALL BASE, COLOR 31 ZEPHYR CB CEILING C1 ARMSTRONG KNIFE EDGE AXIOM TRIM WITH FACTORY MADE OUTSIDE CORNERS AND 9/16" SUPRAFINE XL GRID. ALL WHITE. WITH ULTIMA BEVELED TEGULAR 24x24 TILES. AT ALL CUT EDGES TILE TO BE PAINTED TO MATCH FACE COLOR. FIN. CEILING 8'-0" PAINT P1 PAINT WALLS SHERWIN WILLIAMS SW 7012 CREAMY 0 PAINT EXISTING PAINTED DOORS AND COLOR TO MATCH EXISTING. P4 PAINT SOFFITS TO MATCH WALL COLOR SW 7012 CREAMY TRIMS / SURFACE TREATMENTS 0 SOFTWALLS FABRIC WRAPPED TAC PANELS - KNOLL TEXTILES GLISTEN #WC1071/1 CRYSTAL SUPPLIED BY OWNER. 0 MANUAL MECHOSYSTEMROLLER WINDOW SHADE, SINGLE ROLL, EUROTWILL REVERSIBLE WEAVE 6000 SERIES (3% OPEN). MOUNT AT TOP OF WINDOW AT HEAD. COLOR 6006 SILVER BIRCH DATE: FACILITI DESIGN: DRAWN: une 05, 2013 .RUBEN FIN. FLOOR dik 1ik W -Ort 1� ELEVATIONS AND SECTIONS N SCALE: 1"-=.1-0" 0 s 2 ALE: 1/4"=1'-0" SECTION WEST ELEVATION ROOM 0 NOTES 16 A-301 P0356 4 12 11 0 9 8 7 6 5 2 226)-1-41-12 16 14 1 13 1 12 1 11 1 10 8 7 1 6 5 1 4 PIPING STANDARDS AND SPECIFICATIONS PIPE SERVICE ABBREVIATION PIPE SIZE MATERIAL FITTINGS JOINT INSULATION JACKET MATERIAL DOMESTIC COLD WATER CW, DCW ALL SIZES ASTM B88 TYPE L COPPER ASTM B16,22 STD WROUGHT COPPER ASTM B32 SOLDER 1", k=0.27 (MAX) ASJ DOMESTIC HOT WATER HW, DHW ALL SIZES ASTM B88 TYPE L COPPER ASTM B16.22 STD WROUGHT COPPER ASTM B32 SOLDER 1", k=0.27 (MAX) ASJ DRAIN, WASTE & VENT SAN / V ALL SIZES ASTM A74. CISPI 301 SERVICE WEIGHT CAST IRON HUBLESS ASTM A74, CISPI 301 SERVICE WEIGHT CAST IRON HUBLESS ASTM C564 ELASTOMERIC SEALING SLEEVE STAINLESS STEEL BAND 1" ON FIRST FLOOR ONLY ASTM B3026 TYPE DWV ASME B16.29 WROUGHT COPPER, DWV ASTM B32 SOLDER 95 Sn / 5 Sb, 95,5 Sn / 4 Cu / 0.5 Ag 1" ON FIRST FLOOR ONLY CHILLED WATER CHWS&R ALL SIZES ASTM B88 TYPE L COPPER ASTM B16.22 STD WROUGHT COPPER ASTM B32 SOLDER 1", k=0.27 (MAX) ASJ CONDENSATE DRAIN CD ALL SIZES ASTM B42 TYPE M HARD TEMPER COPPER ASME B16.22 STD WROUGHT COPPER ASTM B32 SOLDER NONE NONE SPECIFICATIONS 1 SOLDER FILLER METALS: ASTM B32, LEAD-FREE ALLOYS. INCLUDE WATER FLUSHABLE FLUX ACCORDING TO ASTM B813. 2 DIELECTRIC FITTINGS: USE FLANGES OR COUPLINGS. UNIONS ARE UNACCEPTABLE 3 INSTALL ESCUTCHEONS FOR PENETRATIONS OF WALLS.. CEILING, AND FLOORS 4 INSTALL SLEEVES FOR PIPES PASSING THROUGH CONCRETE AND MASONRY WALLS, GYPSUM -BOARD PARTITIONS; AND CONCRETE FLOOR AND ROOF SLABS. 5 INSTALL PLUMBING SYSTEMS TO FACILITATE SERVICE, MAINTENANCE AND REPAIR OR REPLACEMENT OF COMPONENTS. 6 ALL WASTE PIPING SHALL BE SLOPED IN ACCORDANCE WITH TABLE 704.1 OF THE NYPC. 7 PROVIDE VAPOR RETARDER ON ALL COLD & CHILLED WATER PIPING INSULATION SYSTEMS. 8 ALL SANITARY DRAIN PIPING AND INSULATION EXPOSED TO VIEW ON THE FIRST FLOOR SHALL BE COMPLETELY COVERED WITH PVC PIPE COVERS. 9 MAINTAIN INDICATED FIRE RATING OF WALLS, PARTITIONS, CEILINGS, AND FLOORS AT PIPE PENETRATIONS. SEAL PIPE PENETRATIONS WITH FIRESTOP MATERIALS 10 DO NOT ENCLOSE, COVER OR PUT PLUMBING PIPING SYSTEMS INTO OPERATION UNTIL IT HAS BEEN INSPECTED AND APPROVED BY THE AUTHORITIES HAVING JURISDICTION. 11 LEAVE ALL NEW OR MODIFIED DOMESTIC WATER PIPING UNCOVERED AND UNCONCEALED UNTIL IT HAS BEEN TESTED. EXPOSE WORK THAT WAS COVERED OR CONCEALED BEFORE IT WAS TESTED. 12 ALL INSULATION AND ADHESIVE SHALL HAVE A MAXIMUM FLAME -SPREAD INDEX OF 25 AND A MAXIMUM SMOKE -DEVELOPED INDEX OF 50 WHEN TESTED IN ACCORDANCE WITH ASTM E84. 13 INSTALL PIPING AT RIGHT ANGLES OR PARALLEL TO BUILDING WALLS. DIAGONAL RUNS ARE PROHIBITED UNLESS SPECIFICALLY INDICATED. 14 SUPPORT PIPING SUCH THAT IT IS FREE OF SAGGING, SLOPED IN ACCORDANCE WITH THE DRAWINGS AND TO BE INDEPENDENT OF EQUIPMENT CONNECTIONS. 15 INSTALL FITTINGS FOR CHANGES IN DIRECTION AND BRANCH CONNECTIONS, INSTALL PIPE SUPPORTS OR HANGERS TO SUPPORT FI 11INGS AT TAKE -OFFS. 16 CONNECT BRANCH PIPING FROM TOP OR SIDE OF HORIZONTAL PIPING. 17 INSTALL VALVES IN ACCESSIBLE LOCATIONS, PROTECT VALVES FROM PHYSICAL DAMAGE. 18 INSTALL METAL TAG ATTACHED WITH METAL CHAIN INDICATING PIPING SYSTEMS. 19 PIPE JOINT CONSTRUCTION: A. REAM ENDS OF PIPES AND TUBES; REMOVE BURRS. B. REMOVE SCALE, DIRT AND DEBRIS FROM INSIDE OF PIPE AND FITTINGS BEFORE ASSEMBLY, C. THREADED JOINTS - THREAD PIPE WITH TAPERED THREADS ACCORDING TO ASME B1.20.1. CUT THREADS FULL AND CLEAN USING SHARP DIES. REAM THREADED PIPE ENDS TO REMOVE BURRS AND RESTORE TO FULL ID. 1. JOIN PIPE FITTINGS AND VALVES AS FOLLOWS: a. APPLY TAPE OR THREAD COMPOUND TO EXTERNAL PIPE THREADS UNLESS DRY SEAL THREADING IS SPECIFIED, b, DAMAGED THREADS: DO NOT USE PIPE OR PIPE FITTINGS WITH THREADS THAT ARE CORRODED OR DAMAGED. DO NOT USE PIPE SECTIONS THAT HAVE CRACKED OR OPEN WELDS. 20 TESTING OF DOMESTIC WATER PIPING: CAP AND SUBJECT DOMESTIC WATER PIPING TO STATIC WATER PRESSURE OF 50 PSIG ABOVE OPERATING PRESSURE. WITHOUT EXCEEDING PRESSURE RATING OF PIPING SYSTEM MATERIALS ISOLATE TEST SOURCE AND ALLOW TO STAND FOR FOUR HOURS, LEAKS AND LOSS IN TEST PRESSURE CONSTITUTE DEFECTS THAT MUST BE REPAIRED REPAIR LEAKS AND DEFECTS WITH NEW MATERIALS AND RETEST PIPING UNTIL SATISFACTORY RESULTS ARE OBTAINED. 21 TESTING OF DOMESTIC WAS IE AND VENT PIPING: CAP AND SUBJECT DOMESTIC WATER PIPING TO STATIC WATER PRESSURE OF 10 FEET HEAD PRESSURE ABOVE HIGHEST POINT OF SYS IEM UNDERGOING TEST ISOLATE TEST SOURCE AND ALLOW TO STAND UNTIL SYSTEM CAN BE VISUALLY INSPECTED BY AUTHORITY HAVING JURISDICTION. LEAKS CONSTITUTE DEFECTS THAT MUST BE REPAIRED REPAIR LEAKS AND DEFECTS WITH NEW MATERIALS AND RETEST PIPING UNTIL SATISFACTORY RESULTS ARE OBTAINED. 22 CLEANING AND DISINFECTION OF POTABLE WATER SYSTEMS: STEP 1: FLUSH PIPING SYSTEM WITH CLEAN: POTABLE WATER UNTIL DIRTY WATER DOES NOT APPEAR AT OUTLETS 23 CLEANING AND PROTECTION OF DOMESTIC WASTE AND VENT PIPING: CLEAN INTERIOR OF PIPING SYSTEM. REMOVE DIRT AND DEBRIS DURING CONSTRUCTION. TAG LOCATION COMPONENTS MANUFACTURER MODEL P B DESCRIPTION NG FIXTURES SCHEDULE MATERIAL FINISH / COLOR COLD WATER HOT WATER WASTE / SAN VENT NOTES STANDARDS KS -1 300J SINK FRANKE E DDB33229-1 TOP -MOUNT, COMPOSITE GRANITE. DOUBLE BOWL, 1 -HOLE COMPOSITE GRANITE MOCHA 1-1/2" 1-1/2" ASME A112,19.3 FAUCET KOHLER VIN TA K-690-2BZ SINGLE -HOLE KITCHEN SINK FAUCET WITH PULL -DO SPOUT PREMIUM METAL OIL RUBBED BRONZE 1/2" 1/2" 2 ASME/ANSI A112.18.1 NOTES: 1 SIZE: 33x22, 9 -INCH DEEP BOWLS, PROVIDE EACH BOWL WITH STAINLESS TURN -SEAL LEAKPROOF BASKET STRAINER, INSTALL IN 36 -INCH BASE CABINET, PROVIDE SILICON SEALANT FOR INSTALLATION. 2 SINGLE HANDLE, SINGLE HOLE 9 -1/2 -INCH HIGH ARC KITCHEN FAUCET WITH PULL-DOWN SPRAYHEAD, 1.8 GPM FLOW RATE, ADA COMPLIANT, INSTALL WITH PROVIDED 2 -1/2 -INCH ESCUTCHEON. WARNING: IT ISA VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER. TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT HIS SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. APPROVAL: E IT S ENGIN ",.RING RONI' ARC CIVIL. ELEC: MECH: HEALTH AND S DATE: vT REVISIONS: DATE: 06/05/13 - ISSUE FOR CONSTRUCTION Q9 E CD LO 0 CO 0- E E ES MOM E as 0 ®eo N = z aCU (13s DATE: June 05, 201; FACILITY: 2026 DESIGN: K. SAMSON DRAWN: kcs NOT USED STANDARDS, SPECIFICATIONS AND SCHEDULES PIPING STANDARDS, SPECIFICATIONS AND EQUIPMENT SCHEDULE MPOOO P0356 16 14 12 10 9 8 7 6 5 1 4 3 2 1 2 1-ILI3 A E F z 6 15 14 13 12 11 10 9 1 8 7 6 1 5 4 3 2 R t23 D D ... .3. ••, D• D D k D.33 ...D., .., „ ••3 „. •,, ..: .3 ...D 3..33i• •, D, i , 303 FAN COIL UNIT r - - — 305A 305 300SB M1, HILLED WATER PIPING (E) 307 3/4" CONDENSATE DRAIN (E) ! , , .,, 300CA 302A 0 2 SCALE: 1/4"=1I-0" 131 ?;2 tt• ; ;;;;23 t2:23 3; ;:tt, 23;t3 ;332 32,t 22233;;; 22,22;3 303 . , . , . - . . , 3 t . ; . , . I 0"0 SA , . . ®14x6 SA RELOCATED FAN COIL UNIT 0 SD - 4VD 00 14x10 SA VD TYP 300 CFM 4x6 SA 307 3/4" CONDENSATE 3.3 23 3 3.2 3 • ; 2 ... . 3 . ;-• DRAIN (E) 3 ;2' t iitt; 300SB ; ; 3 HILLED WATER PIPING (E) 302 300CA 302A MECHANICAL SCOPE OF WORK: 1.0 REMOVE DUCTVVORK, GRILLES, DIFFUSERS AND HANGERS AS INDICATED ON PLAN. 2.0 DISCONNECT AND RELOCATE FAN COIL UNIT, AS INDICATED ON PLAN. RECONNECT CHILLED WATER AND CONDENSATE PIPIING. COORDINATE WITH ARCHITECTURAL AND ELECTRICAL. 3.0 PROVIDE NEW DUCTWORK AND SUPPLY AIR DIFFUSERS AS NOTED ON PLAN. COORDINATE WITH ARCHITECTURAL AND ELECTRICAL. BALANCE TO AIR FLOWS INDICATED ON PLAN. WARNING: IT ISA VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT HIS SEAL AND THE NOTATION "ALTERED BY FOLLOWED BY HIS SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION, DATE: PARTIAL THIRD FLOOR MECHANICAL DEMOLITION PLAN SCALE: 1/4" = 1'-0" PARTIAL THIRD FLOOR MECHANICAL CONSTRUCTION P N SCALE: 4" = 11-0" 6 15 4 1 DUCT SERVICE LOCATION PRESSURE CLASS SEAL CLASS DUCT STANDARDS AND SPECIFICATIONS LEAKAGE CLASS RECT ROUND MATERIAL LINING INSULATION THICKNESS (IN) MATERIAL FIELD JACKET VAPOR RETARDER FINISH SUPPLY - INTERIOR 2" POS 24 12 G90 GALVANIZED NONE 1.5 TYPE B NONE YES FACTORY SPECS 1 ALL DUCTWORK & ACCESSORIES SHALL BE FABRICATED & INSTALLED IN COMPLIANCE WITH THE LATEST ISSUE OF SMACNA'S HVAC DUCT CONSTRUCTION STANDARDS. 2 CONSTRUCT IEES, BENDS, AND ELBOWS WITH RADIUS OF NOT LESS THAN 1.5 TIMES THE WIDTH OF DUCT ON CENTER LINES. 3 INCREASE DUCT SIZES GRADUALLY, IN COMPLIANCE WITH FIGURE 4-7 OF SMACNA'S DUCT CONSTRUCTION STANDARDS. BRANCH CONNECTIONS SHALL BE MADE WITH A 45 DEGREE ENTRY. 4 SEALANTS & GASKETS: CHARACTERISTICS SHALL BE A MAXIMUM FLAME -SPREAD INDEX OF 25, AND MAXIMUM SMOKE -DEVELOPED INDEX OF 50 WHEN TESTED TO UL 723. 5 ALL MANUAL BALANCING DAMPERS SHALL BE PROVIDED WITH LOCKING HAND QUADRANT. 6 PROVIDE FLEXIBLE CONNECTORS TO CONNECT DUCTS TO EQUIPMENT. 7 REMOVE SURFACE CONTAMINANTS AND DEPOSITS FROM DUCTWORK AND EQUIPMENT PRIOR TO TESTING AND BALANCING. 8 ALL INSULATION AND ADHESIVE SHALL HAVE A MAXIMUM FLAME -SPREAD INDEX OF 25 AND A MAXIMUM SMOKE -DEVELOPED INDEX OF 50 WHEN TESTED IN ACCORDANCE WITH ASTM E84. TYPE B INSULATION: FIBERGLASS BLANKET, 0.75 POUNDS PER CUBIC FOOT DENSITY, MINIMUM R -VALUE OF 5, COMPLETE WITH FACTORY APPLIED VAPOR BARRIER. 9 FLEXIBLE DUCTS SHALL BE BLACK POLYMER SUPPORTED BY HELICALLY WOUND SPRING STEEL WIRE, FIBROUS GLASS INSULATION WITH VAPOR BARRIER FILM RATED FOR A MIN. 4 -INCH WG. TAG SERVICE MANUFACTURER MODEL TYPE DIFFUSER SCHEDULE STYLE MATERIAL COLOR NECK SIZE S D-1 SUPPLY AIR TITUS OMNI -NT 24x24 LAY -IN -NARROW TEE ARCHITECTURAL CEILING DIFFUSER SQUARE PANEL STEEL WHITE 10 -INCH SCOPE OF WORK GENERAL NOTES: 1.0 COORDINATE ALL WORK WITH ARCHITECTURAL AND ELECTRICAL WORK. KEYED DEMOLITION NOTES: REMOVE RETURN AIR GRATES IN CEILING GRID BELOW FAN COIL UNIT. REMOVE ALL DUCTWORK CONNECTED TO EXISTING FAN COIL UNIT. 0 DISCONNECT CHILLED WATER AND CONDENSATE DRAIN PIPING CONNECTED TO FAN COIL UNIT. PIPING WILL BE RECONNECTED. RELOCATE FAN COIL UNIT APPROXIMATELY 12 -INCHES TO ACCOMMODATE A NEW CEILING SYSTEM. 0 EXISTING SURFACE MOUNTED FAN COIL UNIT THERMOSTAT AND THREE SPEED SWITCH SHALL REMAIN AS -IS, THEY WILL BE ENCLOSED AS PART OF THE ARCHITECTURAL WORK. KEYED CONSTRUCTION NOTES: EXISTING FAN COIL UNIT RELOCATED APPROXIMATELY 12 -INCHES. COORDINATE FINAL LOCATION WITH NEW CEILING SYSTEM AND LIGHTING. MAINTAIN MAINTENANCE CLEARANCES FOR FAN COIL FILTER REPLACEMENT. PROVIDE VIBRATION ISOLATION TO FAN COIL SUPPORT. EXTEND AND RECONNECT EXISTING CHILLED WATER PIPING TO FAN COIL UNIT, INSULATE ALL PIPING. EXTEND AND RECONNECT EXISTING CONDENSATE DRAIN PIPING TO FAN COIL UNIT. INSTALL ALL SUPPLY AIR DUCTWORK AS HIGH AS POSSIBLE. INSTALL LOCKING MANUAL BALANCING DAMPERS IN EACH DUCT BRANCH, LOCATE FOR ACCESSIBILITY. FLEXIBLE DUCTWORK CONNECTED TO SUPPLY AIR DIFFUSERS SHALL BE INSTALLED WITHOUT CRUSHING OR KINKING THE FLEX DUCT TO ALLOW FOR PROPER AIRFLOW TO EACH DIFFUSER. ALL SUPPLY AIR DUCTWORK SHALL BE INSULATED. PROVIDE NEW AIR FILTER SET FOR EXISTING FAN COIL UNIT, FIELD VERIFY FILTER DIMENSIONS. CLEAN EXISTING SUPPLY AIR FAN AND CABINET. INSURE EXISTING ELECTRICAL MOTOR IS IN PROPER OPERATIONAL CAPACITY. 0 PROVIDE DETAILED BALANCE REPORT THAT SHALL CONTAIN FAN COIL SUPPLY AND RETURN AIRFLOWS, DISCHARGE AIR TEMPERATURE WITH CORRESPONDING OUTSIDE AIR TEMPERATURE AND CHILLED WATER INLET AND OUTLET TEMPERATURES AND FLOW. PROVIDE MOTOR AMPERAGE AT DESIGN AIRFLOW. RE -CALIBRATE EXISTING WALL MOUNTED THERMOSTAT. FA E ENGINEERI :G ENVIRONMENTA HEALTH AND SAF ARCH• CIVIL. ELEC: MECH: 11413 to, REVISIONS: DATE: 06105/13 - ISSUE FOR CONSTRUCTION c.) 12 NOT USED 10 EQUIPMENT SCHEDULES AND SPECIFICATIONS NOTES DATE: une 05, 201 FACILITY: 2026 DESIGN: K. SAMSON DRAWN: kcs PARTIAL THIRD FLOOR MECHANICAL PLANS AND SCHEDULES M100 P0356 A 2210 -I-11-i 16 15 14 2 0 PLUMBING SCOPE OF WORK: 1.0 PROVIDE NEW KITCHEN SINK (KS -10 AND INSTALL IN NEW SINK BASE INCLUDING DCW, DHW AND DRAIN PIPING AS INDICATED ON PLANS. COORDINATE WITH ARCHITECTURAL DRAWINGS FOR ADDITIONAL DETAILS. WARNING: IT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT HIS SEAL AND THE NOTATION "ALTERED BY' FOLLOWED BY HIS SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. AP" +►VAL: DATE: /4 -INCH DHW,. /4 -INCH DHW (E) 300SB 3/4 -INCH DCW, 2 -INCH DCW (E) NOTES 33 13C AM. 33 =2033 33333 3/4 -INCH DHW & DCW KITCHEN SINK (KS -1) 1-1/2 INCH DRAIN, 1/2 -INCH DHW & DCW FUTURE SINK LOCATION GENERAL NOTES: FA' IL' IES ENGIN ENVIRONMENTAL HEALTH AND SAFETY ARCH. �.... CIVIL ELEC: Ct MECH. REVISIONS: DATE: 06/05/13 - ISSUE FOR CONSTRUCTION 1.0 COORDINATE ALL WORK WITH ARCHITECTURAL AND ELECTRICAL WORK. KEYED CONSTRUCTION NOTES: Q INSTALL SINK AT LOCATION SHOWN, SINK AND FAUCET ARE PROVIDED AND INSTALLED BY THE PLUMBING CONTRACTOR. SINK INSTALLATION SHALL MEET ALL MANUFACTURER INSTALLATION REQUIREMENTS, PROVIDE SECUREMENT CLIPS, BRACKETS AND SEALANT AS REQUIRED. /2 -INCH VENT - BS= 329331,13,111 31333,3 33 1¢ $3:301 13 la 33333 333303 .13 =PIS 36 =IMO 13 .13343111 ell.* 1-1/2 INCH DRAIN TO FIRST FLOOR 1 -1/2 -INCH DRAIN UP, 1 -1/2 -INCH VENT UP, 1/2 -INCH DHW & DCW UP SCALE: 1/4"=1'-0" SCALE: 1/4"=1'-0" SCALE: 1/4" = 1`-0" PARTIA SECOND P U BNG CONSTRUCTION PLAN SCALE: 1/4" = 1 °-0" ROUTE 1 -1/2 -INCH SANITARY DRAIN, 1/2 -INCH HOT AND COLD WATER TO SINK THROUGH BASE CABINET. LOCATE AS FAR TO THE REAR OF THE CABINET AS POSSIBLE. ROUTE 1 -1/2 -INCH DRAIN, 1 -1/2 -INCH VENT, 1/2 -INCH HOT AND COLD WATER DOWN THROUGH THIRD FLOOR CONCRETE SLAB, FIELD CUT FLOOR OPENING, SEAL OPENINGS WATER TIGHT WITH FIRE RESISTIVE SEALANT. COORDINATE LOCATION WITH EXISTING CONCRETE BEAM BELOW FLOOR. Q ROUTE 1 -1/2 -INCH VENT, 3/4 -INCH HOT AND COLD WATER AS HIGH AS POSSIBLE AND TIGHT TO THIRD FLOOR BEAM, PIPING WILL BE ENCLOSED IN NEW BUILT -OUT WALL (SEE A-100 & A-102). INSULATE ALL WATER PIPING. ROUTE 1 -1/2 -INCH VENT, 3/4 -INCH HOT AND COLD WATER ABOVE THIRD FLOOR CORRIDOR DROP CEILING, CONNECT TO EXISTING SERVICES WITHIN PIPE CHASE ADJACENT TO TOILET ROOM. COORDINATE PIPE ROUTE WITH EXISTING SERVICES. ROUTE 1 -1/2 -INCH SANITARY DRAIN, 1/2 -INCH HOT AND COLD WATER FROM THIRD FLOOR DOWN TO CONNECT TO A FUTURE SINK LOCATED IN THE SECOND FLOOR BASE CABINETRY. PIPING SHALL TERMINATE JUST INSIDE OF THE EXISTING BASE CABINET AND SHALL BE SECURELY CAPPED OFF. LOCATE AS FAR TO THE REAR OF THE CABINET AS POSSIBLE IN ANTICIPATION OF A FUTURE SINK BEING INSTALLED. 7 ROUTE 1 -1/2 -INCH SANITARY DRAIN FROM RISER TO THIRD FLOOR AND CONNECTION TO FUTURE SECOND FLOOR SINK ALONG THE WALL IN OFFICE 222, ROUTE TIGHT TO WALL AND PENETRATE THE SECOND FLOOR CONCRETE SLAB NEAR LOCATION SHOWN. INSULATE DRAIN PIPING WITH 1/2 -INCH THICK FIBERGLASS INSULATION. DRAIN PIPING WILL BE BOXED IN WITH A SOFFIT. WHERE THE DRAIN PENETRATES THE SECOND FLOOR SLAB, PROVIDE A 1 -1/2 -INCH CLEANOUT WITH STAINLESS STEEL WALL CLEAN OUT PLATE. Q PIPING WILL CONTINUE FROM THE SECOND FLOOR VERTICALLY THROUGH THE FIRST FLOOR DOWN TO THE BASEMENT, PENETRATE THE FIRST FLOOR CONCRETE SLAB LOCATE AS CLOSE TO WALL AND COLUMN AS POSSIBLE, SEAL OPENING WITH FIRE RESISTIVE SEALANT. COORDINATE LOCATION WITH EXISTING CONTROLS CONDUIT LOCATED IN THE BASEMENT CEILING. PIPING WILL REMAIN EXPOSED, COMPLETELY INSULATE THE DRAIN PIPING ON THE FIRST FLOOR, INSULATE WITH 1/2 -INCH THICK FIBERGLASS INSULATION, COVER WITH WHITE PVC PIPE JACKET IN ITS ENTIRETY ON THE FIRST FLOOR. CONNECT 1 -1/2 -INCH DRAIN PIPING TO EXISTING 4 -INCH ABOVE DOOR TO JANITOR STOREROOM. REMOVE EXISTING 4 -INCH CLEANOUT PLUG AND CONNECT. PROVIDE NEW CLEANOUT AT CONNECTION. COORDINATE LOCATION WITH EXISTING CONTROLS CONDUIT ALONG WALL. BOOCF 4 -INCH SANITARY (E DATE: June 05, 2013 FACILITY: 2026 DESIGN: K. SAMSON DRAWN: Ices PLUMBING CONSTRUCTION PLANSco 1 NOT USED PARTIAL BASEMENT P U BING CONSTRUCTION P N NOTES P-100 P0356 14 13 12 11 10 9 8 7 6 5 4 2 Z2 LI L15 Cl 6 15 14 13 12 11 10 8 7 6 5 4 2 NOT USED ELECTRICAL ABBREVIATIONS AOM ADDRESSABLE OUTPUT MODULE ARB AUXILIARY RELAY BOARD AMM ADDRESSABLE MONITOR MODULE ATS AUTOMATIC TRANSFER SWITCH C CONDUIT CR CONTROL RELAY FSD FAN SHUT DOWN FAAP FIRE ALARM ANNUNCIATOR PANEL LFMC LIQUID TIGHT FLEX BLE METALLIC CONDUIT PVC POLYVINYL CHLORIDE FACP FIRE ALARM CONTROL PANEL SNAG SUPPLEMENTAL NOTIFICATION AP CE PANEL EC ELECTRICAL CONTRACTOR CKT CIRCUIT BKR BREAKER LTG LIGHTING EMT ELECTRICAL METALLIC TUBING RGS RIGID GALVANI7FD STEEL AFF ABOVE FINISHED FLOOR UE UNDERGROUND ELECTRIC OE OVERHEAD ELECTRIC PC PHOTO CELL LC LIGHTING CONTACTOR UPS UNINTERRUPTIBLE POWER SUPPLY ATS AUTOMATIC TRANSFER SWITCH MOLDED FUSION T EXOTHERMIC WELDS FOR GRID CONNECTION , UNDERGROUND WORK. MANUAL FER SWITCH GAA GENERATOR ALARM ANNUNCIATOR GND GROUND HP HORSEPOWER No. 4/0 STRANDED BARE COPPER PIGTAIL MINIMUM 6'-0" COIL FOR FUTURE USE. KILOWATT MCB MAIN CIRCUIT BREAKER MLO MAIN LUG ONLY NIC NOT IN CONTRACT TSP STED SHIELDED PAIR TYP TYPICAL UOt UNLESS OTHERWISE INDICATED V VOLT WP WATERPROOF PP POWER PANEL LIGHTING SYMBOLS ® TRACK LIGHTS 0135 (:)200 HEAT DETECTOR 135 F OR 200 F FIXED TEMP SENSOR SD FLUORESCENT LIGHTS, 08T TRANSMITTER BEAM DETECTOR SD BR RECEIVER BEAM DETECTOR DD SURFACE MOUNTED OR RECESSED DOWN LIGHTS. FS LIGHTING DIMMER. TS EXIT LIGHT. IEMf EMERGENCY WALLPACK LUMINAIRE DRAWOUT DEVICE EMERGENCY/EXIT COMBO WALLPACK LUMINAIRE EM FIRE ALARM HORN ONLY FA EM FB EM LIGHTING FIXTURE. FA = FIXTURE TYPE, REFER TO SPECIFICATIONS. a = CONTROL BY WALL SWITCH MARKED SAME EM = EMERGENCY POWER SOURCE. 1 1 a $3 $4 THREE OR FOUR WAY SWITCH. !APS I SINGLE POLE SWITCHES GANGED ON A SINGLE PLATE. MARKED SAME AS ABOVE. IRTSI OCCUPANCY SENSOR. "C" INDICATES CEILING MOUNTED, "W" INDICATES WALL MOUNTED. l l til COMBINATION LIGHT SWITCH & OCCUPANCY SENSOR. SECURITYSYMBOLS IPBI SECURITY SYSTEM PANIC BUTTONS IDS I SECURITY SYSTEM DOOR SWITCH FIRE ALARM SYMBOLS ® MAGNETIC DOOR HOLDER 0135 (:)200 HEAT DETECTOR 135 F OR 200 F FIXED TEMP SENSOR SD SMOKE DETECTOR PHOTOELECTRON! C SENSOR 08T TRANSMITTER BEAM DETECTOR SD BR RECEIVER BEAM DETECTOR DD DUCT DETECTOR FS FLOW PRESSURE SWITCH TS TAMPER SWITCH PS LOW AIR SWITCH DRAWOUT DEVICE FIRE ALARM STROBE/HORN COMBO CT FIRE ALARM HORN ONLY --En--3 E- PT FIRE ALARM PULL STATION !RAI] REMOTE ALARM INDICATOR ® !APS I AUXILIARY POWER SUPPLY. IRTSI REMOTE TEST SWITCH/STATION 0 FIRE ALARM STROBE ELECTRICAL ONE -LINE SYMBOLS ® AIR BREAK INTERRUPTER SWITCH 51 POINT OF DEMOLITION TO EXISTING WORK TO REMAIN a---- - FUSED DISCONNECT SWITCH I II- REMOVAL WORK (DASHED) THERMAL MAGNETIC MOLDED CASE CIRCUIT BREAKER CIRCUIT BREAKER SOLID STATE TRIP CHARACTERISTICS INDICATED BY SUBSCRIPTS: AT - TRIP COIL AMPERE RATING AF - FRAME SIZE AMPERE RATING CL - CURRENT LIMITING L - LONG TIME TRIP S - SHORT TIME TRIP I - INSTANTANEOUS TRIP G - GROUND FAULT TRIP SH - SHUNT TRIP 1200AT 0 DRAWING CONSTRUCTION KEYED NOTE INDICATOR 1600AF BRANCH CIRCUITRY TO POWER RECEPTACLE DEVICE(S) IS NOT INDICATED ON THE CONTRACT DOCUMENTS. THE ALPHA -NUMERIC TEXT ADJACENT TO THE DEVICE SYMBOL INDICATES THE PANEL AND CIRCUIT NUMBER ITS FED FROM. FOR EXAMPLE: P -1N12 INDICATES THAT THE DEVICE IS FED FROM PANEL P -1A, CIRCUIT #12. PROVIDE CIRCUITRY TO DEVICE(S) AS FOLLOWS: DEVICES INDICATED WITH THE SAME CIRCUIT NUMBER SHALL BE CIRCUITED TOGETHER TO A 20AMP/1-POLE CIRCUIT BREAKER USING 2#12, 1#12G, IN 3/4 INCH EMT CONDUIT UNLESS INDICATED OTHERWISE. A MAXIMUM OF FOUR 20 AMP, SINGLE PHASE BRANCH CIRCUITS CONSISTING OF (8#12, 1#12G) SHALL BE PERMITTED IN ONE INCH EMT CONDUIT. « > DRAWOUT DEVICE PLUGMOLD CT CURRENT TRANSFORMER --En--3 E- PT POTENTIAL TRANSFORMER it o O —a MOV TYPE LIGHTNING ARRESTOR SIZE AND CLASS AS INDICATED ® METER/INSTRUMENT LETTER INDICATES FUNCTION A - AMMETER PF - POWER FACTOR METER S -SYNCHROSCOPE VH - VAR -HOUR METER V - VOLT METER VAR- VARMETER W - WATTMETER WH-WATTHOUR METER WHD- WATTHOUR METER WIDEMAND REGISTER CM CIRCUIT MONITOR AS METER/INSTRUMENT SWITCH LETTERS INDICATE FUNCTION: AS - AMMETER SWITCH VS - VOLTMETER SWITCH WS - WATTMETER SWITCH r T TRANSFORMER, REFER TO SCHEDULE FOR SIZE AND TYPE �--� t G I GENERATOR SET DJ TRANSFER SWITCH, RATING AS INDICATED. ATS = AUTOMATIC COMBINATION STARTER. O METERING DEVICE, TYPE INDICATED ON CONTRACT DOCUMENTS. V GROUND CONNECTION 10'-0" x 5/8" DIAMETER, COPPER CLAD GROUND ROD. TOP OF ROD 2'0" BELOW FINISHED GRADE UNLESS WELDS ONLY CIRCUIT CONDUIT DROP OR RISE AS INDICATED MOLDED FUSION T EXOTHERMIC WELDS FOR GRID CONNECTION , UNDERGROUND WORK. LP1 HOMERUN TO PANEL LP1, CIRCUIT #3. FED FROM 20A -1P BREAKER IS INTENDED UNLESS NOTED OTHERWISE. RUN GREENWIRE GROUND FOR ALL CIRCUITS. PROVIDE ONE GROUND PER CIRCUIT UNLESS SHOWN OTHERWISE. 1 I GROUND TERMINATION TO EQUIPMENT. (FRAME, GROUND BUS, TRANSFORMER NEUTRAL) WIRE MOLD SURFACE RACEWAY —W No. 4/0 STRANDED BARE COPPER PIGTAIL MINIMUM 6'-0" COIL FOR FUTURE USE. GENERAL Y BOL LEGEND ENLARGED DETAIL EXTERIOR ELEVATION F10 A103 TF10 A103 INTERIOR ELEVATION D16 D16> A103 A103 22 KEYNOTE DEMOLITION N KEYNOTE NEW WORK MATCH LINE NORTH ARROW SECTION GENERAL ELECTRICAL SYMBOLS ® POINT OF CONNECTION TO EXISTING WORK TO REMAIN 51 POINT OF DEMOLITION TO EXISTING WORK TO REMAIN a---- - EXISTING WORK TO REMAIN (GRAYSCALE) - REMOVAL WORK (DASHED) NEW WORK (BOLD) DRAWING REMOVAL KEYED NOTE INDICATOR 0 DRAWING CONSTRUCTION KEYED NOTE INDICATOR P -1A 12 P 1A 12 P -1A 0 12 BRANCH CIRCUITRY TO POWER RECEPTACLE DEVICE(S) IS NOT INDICATED ON THE CONTRACT DOCUMENTS. THE ALPHA -NUMERIC TEXT ADJACENT TO THE DEVICE SYMBOL INDICATES THE PANEL AND CIRCUIT NUMBER ITS FED FROM. FOR EXAMPLE: P -1N12 INDICATES THAT THE DEVICE IS FED FROM PANEL P -1A, CIRCUIT #12. PROVIDE CIRCUITRY TO DEVICE(S) AS FOLLOWS: DEVICES INDICATED WITH THE SAME CIRCUIT NUMBER SHALL BE CIRCUITED TOGETHER TO A 20AMP/1-POLE CIRCUIT BREAKER USING 2#12, 1#12G, IN 3/4 INCH EMT CONDUIT UNLESS INDICATED OTHERWISE. A MAXIMUM OF FOUR 20 AMP, SINGLE PHASE BRANCH CIRCUITS CONSISTING OF (8#12, 1#12G) SHALL BE PERMITTED IN ONE INCH EMT CONDUIT. PLUGMOLD X X X X X X X LL"1 PANELBOARD. JUNCTION BOX. GFI DUPLEX CONVENIENCE RECEPTACLE, GF = GROUND FAULT INTERRUPTER PROTECTION. TWO DUPLEX CONVENIENCE RECEPTACLES MOUNTED ON A SINGLE GANG PLATE. 5 20R SPECIAL PURPOSE RECEPTACLE DEVICE. PROVIDE SINGLE DEVICE WITH NEMA RATING AS INDICATED AND MATCHING COVER PLATE. <:>‘ MOTOR, NUMBER INSIDE SYMBOL INDICATES HORSEPOWER. MANUAL MOTOR STARTER, SURFACE MOUNTED UNLESS OTHERWISE INDICATED. DJ DISCONNECT SWITCH. COMBINATION STARTER. O METERING DEVICE, TYPE INDICATED ON CONTRACT DOCUMENTS. V COMMUNICATION OUTLET_ SINGLE POLE SWITCH. CIRCUIT CONDUIT DROP OR RISE AS INDICATED C LP1 HOMERUN TO PANEL LP1, CIRCUIT #3. FED FROM 20A -1P BREAKER IS INTENDED UNLESS NOTED OTHERWISE. RUN GREENWIRE GROUND FOR ALL CIRCUITS. PROVIDE ONE GROUND PER CIRCUIT UNLESS SHOWN OTHERWISE. THERMOSTAT WIRE MOLD SURFACE RACEWAY —W VFD VARIABLE FREQUENCY DRIVE. �j GENERATOR EMERGENCY SHUTDOWN STATION. WEATHERPROOF, BREAK -GLASS TYPE. GRA GENERATOR REMOTE ANNUNCIATOR 3 -SPD THREE SPEED SWITCH SYMBOLOGY ELECTRICAL SCOPE OF WORK: 1.0 PROVIDE ELECTRICAL SUPPORT TO MAKE INTERIOR MODIFICATIONS TO EXISTING SUITE 300 AND RM. 305. .WARNING: IT ISA VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT HIS SEAL AND THE NOTATION "ALTERED SY" FOLLOWED BY HIS SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. ELECTRICAL SCOPE OF WORK GENERAL NOTES: 1.0 THESE DRAWINGS ARE FOR CORNELL UNIVERSITY USE ONLY. CONTACT THE CORNELL UNIVERSITY PROJECT REPRESENTATIVE WITH ELECTRICAL QUESTIONS. 2.0 ELECTRICAL SCHEMATICS INDICATED ON CONTRACT DOCUMENTS ARE DIAGRAMMATIC. IT IS NOT THE INTENT TO SHOW EXACT OR MOST EFFICIENT ROUTING. VERIFY ALL DIMENSIONS AND FIELD CONDITIONS ON SITE. ANY CONFLICTS BETWEEN CONSTRUCTION DOCUMENTS AND FIELD CONDITIONS SHALL BE BROUGHT TO CORNELL'S PROJECT MANAGER FOR RESOLUTION BEFORE WORK PROCEEDS. 3.0 ASSURE PUBLIC AND WORKER SAFETY AT ALL TIMES. PROTECT ADJOINING AREAS FROM DAMAGE AND DUST. REMOVE ALL DEBRIS FROM SITE AND DISPOSE OF WASTE MATERIAL IN A SAFE MANNER. KEEP THE PREMISES FREE OF DEBRIS FROM THE EXECUTION OF WORK. DELIVER A FINAL PRODUCT THAT IS CLEAN AND OPERABLE. 4.0 FIRE STOP ELECTRICAL PENETRATIONS THROUGH FIRE RATED WALLS AND/OR FLOORS WITH MATERIAL EQUAL IN RATING TO THE CONSTRUCTION OF THE MATERIAL PENETRATED. 5.0 PERFORM WORK IN ACCORDANCE WITH THE REQUIREMENT OF THE LATEST PUBLICATIONS OF THE NEC, NEW YORK STATE UNIFORM FIRE PREVENTION AND BUILDING CODE, NEW YORK STATE ENERGY CODE, AND LOCAL CODES APPLICABLE TO THE PARTICULAR WORK. 6.0 WORK SHALL BE COMPLETED AS SPECIFIED AND INDICATED ON CONTRACT DOCUMENTS. ANY SUGGESTED ALTERNATE MANUFACTURER OR METHOD OF INSTALLATION SHALL BE SUBMITTED TO PROJECT ENGINEER FOR APPROVAL PRIOR TO ORDERING ANY MATERIALS OR COMMENCING EXECUTION OF THE WORK. 7.0 GROUNDING SHALL BE IN STRICT ACCORDANCE WITH NEC ARTICLE 250. PROVIDE EQUIPMENT GROUND CONDUCTOR WITH EACH BRANCH CIRCUIT INDICATED ON CONTRACT DOCUMENTS. EQUIPMENT GROUND CONDUCTOR SHALL BE ROUTED WITH ASSOCIATED PHASE CONDUCTORS. 8.0 PROVIDE A NEW TYPE WRITTEN DIRECTORY FOR EACH PANELBOARD. LABEL ALL NEW DEVICE FACEPLATES WITH SOURCE AND CIRCUIT NUMBER. PROVIDE PERMANENT LABEL ON SWITCHING DEVICES INDICATING EQUIPMENT SERVICE AND INVENTORY NUMBER. COORDINATE EQUIPMENT INVENTORY NUMBERS WITH CORNELL UNIVERSITY'S MECHANICAL SHOP, 255-8667. 9.0 CIRCUITS RATED 20 -AMP, 120 VOLT SHALL CONTAIN SEPARATE NEUTRAL CONDUCTORS. 10.0 CONDUCTORS SHALL BE A MINIMUM 12AWG, STRANDED COPPER, 600VAC, 90 DEGREE C, TYPE THHN/THWN FOR DRY AREAS AND XHHW/THWN FOR WET AREAS. 0 CONDUIT EXPANSION JOINTS SHALL BE INSTALLED AS PER NEC AND WHERE BUILDING VIBRATION JOINTS EXIST. 2.0 CONDUITS SHALL BE A MINIMUM OF 3/4 INCHES DIAMETER. CONDUITS SHALL BE ELECTRICAL METALLIC TUBING (EMT) AND SURFACE MOUNTED UNLESS NOTED OTHERWISE. 0 AIC RATING OF NEW CIRCUIT BREAKERS SHALL MATCH RATING OF RESPECTIVE PANELBOARD. SIZE AS INDICATED. 14.0 PROVIDE PULL STRING THROUGH NEW CONDUIT AND BOXES. PROVIDE SUPPORT HANGERS FOR CONDUIT AS NEEDED. 15.0 INSTALL RACEWAY SYSTEMS ENSURING PROPER ACCESS TO EQUIPMENT AND DEVICES AND WITH SUFFICIENT SPACE TO PERFORM ROUTINE MAINTENANCE AND REPAIR. RACEWAYS THAT ARE NOT INSTALLED WITH THIS REQUIREMENT IN MIND SHALL BE RELOCATED AT NO EXPENSE TO THE UNIVERSITY UNTIL DEFICIENCIES ARE CORRECTED. ABBREVIATIONS SUBMITTAL SCHEDU E GENE NOTES ENVIRON ARCH: CIVIL: ELEC• MECH: TH AND REVISIONS: DATE: 06/05/13 - ISSUE FOR CONSTRUCTION cu E \�Lo O © co E. ELECTRICAL SCOPE OF WORK, GENERAL NOTES, SUBMITTAL SCHEDULE, SYMBOLOGY AND ABBREVIATIONS E-000 P0356 N z 0) T 16 14 13 12 10 9 7 6 4 2 zap -Liqr, 1Z SUB I A SCHEDULE 1.0 LUMINAIRES, PROVIDE PRODUCT DATA. 2.0 FIRE ALARM DEVICES, PROVIDE PRODUCT DATA & WIRING DIAGRAM. 3.0 DEVICES FOR AV WORK, PROVIDE PRODUCT DATA. ELECTRICAL SCOPE OF WORK: 1.0 PROVIDE ELECTRICAL SUPPORT TO MAKE INTERIOR MODIFICATIONS TO EXISTING SUITE 300 AND RM. 305. .WARNING: IT ISA VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT HIS SEAL AND THE NOTATION "ALTERED SY" FOLLOWED BY HIS SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. ELECTRICAL SCOPE OF WORK GENERAL NOTES: 1.0 THESE DRAWINGS ARE FOR CORNELL UNIVERSITY USE ONLY. CONTACT THE CORNELL UNIVERSITY PROJECT REPRESENTATIVE WITH ELECTRICAL QUESTIONS. 2.0 ELECTRICAL SCHEMATICS INDICATED ON CONTRACT DOCUMENTS ARE DIAGRAMMATIC. IT IS NOT THE INTENT TO SHOW EXACT OR MOST EFFICIENT ROUTING. VERIFY ALL DIMENSIONS AND FIELD CONDITIONS ON SITE. ANY CONFLICTS BETWEEN CONSTRUCTION DOCUMENTS AND FIELD CONDITIONS SHALL BE BROUGHT TO CORNELL'S PROJECT MANAGER FOR RESOLUTION BEFORE WORK PROCEEDS. 3.0 ASSURE PUBLIC AND WORKER SAFETY AT ALL TIMES. PROTECT ADJOINING AREAS FROM DAMAGE AND DUST. REMOVE ALL DEBRIS FROM SITE AND DISPOSE OF WASTE MATERIAL IN A SAFE MANNER. KEEP THE PREMISES FREE OF DEBRIS FROM THE EXECUTION OF WORK. DELIVER A FINAL PRODUCT THAT IS CLEAN AND OPERABLE. 4.0 FIRE STOP ELECTRICAL PENETRATIONS THROUGH FIRE RATED WALLS AND/OR FLOORS WITH MATERIAL EQUAL IN RATING TO THE CONSTRUCTION OF THE MATERIAL PENETRATED. 5.0 PERFORM WORK IN ACCORDANCE WITH THE REQUIREMENT OF THE LATEST PUBLICATIONS OF THE NEC, NEW YORK STATE UNIFORM FIRE PREVENTION AND BUILDING CODE, NEW YORK STATE ENERGY CODE, AND LOCAL CODES APPLICABLE TO THE PARTICULAR WORK. 6.0 WORK SHALL BE COMPLETED AS SPECIFIED AND INDICATED ON CONTRACT DOCUMENTS. ANY SUGGESTED ALTERNATE MANUFACTURER OR METHOD OF INSTALLATION SHALL BE SUBMITTED TO PROJECT ENGINEER FOR APPROVAL PRIOR TO ORDERING ANY MATERIALS OR COMMENCING EXECUTION OF THE WORK. 7.0 GROUNDING SHALL BE IN STRICT ACCORDANCE WITH NEC ARTICLE 250. PROVIDE EQUIPMENT GROUND CONDUCTOR WITH EACH BRANCH CIRCUIT INDICATED ON CONTRACT DOCUMENTS. EQUIPMENT GROUND CONDUCTOR SHALL BE ROUTED WITH ASSOCIATED PHASE CONDUCTORS. 8.0 PROVIDE A NEW TYPE WRITTEN DIRECTORY FOR EACH PANELBOARD. LABEL ALL NEW DEVICE FACEPLATES WITH SOURCE AND CIRCUIT NUMBER. PROVIDE PERMANENT LABEL ON SWITCHING DEVICES INDICATING EQUIPMENT SERVICE AND INVENTORY NUMBER. COORDINATE EQUIPMENT INVENTORY NUMBERS WITH CORNELL UNIVERSITY'S MECHANICAL SHOP, 255-8667. 9.0 CIRCUITS RATED 20 -AMP, 120 VOLT SHALL CONTAIN SEPARATE NEUTRAL CONDUCTORS. 10.0 CONDUCTORS SHALL BE A MINIMUM 12AWG, STRANDED COPPER, 600VAC, 90 DEGREE C, TYPE THHN/THWN FOR DRY AREAS AND XHHW/THWN FOR WET AREAS. 0 CONDUIT EXPANSION JOINTS SHALL BE INSTALLED AS PER NEC AND WHERE BUILDING VIBRATION JOINTS EXIST. 2.0 CONDUITS SHALL BE A MINIMUM OF 3/4 INCHES DIAMETER. CONDUITS SHALL BE ELECTRICAL METALLIC TUBING (EMT) AND SURFACE MOUNTED UNLESS NOTED OTHERWISE. 0 AIC RATING OF NEW CIRCUIT BREAKERS SHALL MATCH RATING OF RESPECTIVE PANELBOARD. SIZE AS INDICATED. 14.0 PROVIDE PULL STRING THROUGH NEW CONDUIT AND BOXES. PROVIDE SUPPORT HANGERS FOR CONDUIT AS NEEDED. 15.0 INSTALL RACEWAY SYSTEMS ENSURING PROPER ACCESS TO EQUIPMENT AND DEVICES AND WITH SUFFICIENT SPACE TO PERFORM ROUTINE MAINTENANCE AND REPAIR. RACEWAYS THAT ARE NOT INSTALLED WITH THIS REQUIREMENT IN MIND SHALL BE RELOCATED AT NO EXPENSE TO THE UNIVERSITY UNTIL DEFICIENCIES ARE CORRECTED. ABBREVIATIONS SUBMITTAL SCHEDU E GENE NOTES ENVIRON ARCH: CIVIL: ELEC• MECH: TH AND REVISIONS: DATE: 06/05/13 - ISSUE FOR CONSTRUCTION cu E \�Lo O © co E. ELECTRICAL SCOPE OF WORK, GENERAL NOTES, SUBMITTAL SCHEDULE, SYMBOLOGY AND ABBREVIATIONS E-000 P0356 N z 0) T 16 14 13 12 10 9 7 6 4 2 zap -Liqr, 1Z 16 15 4 12 0 3 2 1 INDICATES CIRCUIT NUMBER & THE CIRCUIT BREAKER IS LOCATED IN PANEL "W". EXISTING PANEL "W" 0 2 4 SCALE: 1/4"=1'-0' GENERAL DEMOLITION NOTES: .0 COORDINATE PHONE/DATA WORK WITH SHAWN WALKER (255-5313). 2.0 REFER TO ARCHITECTURAL DRAWINGS FOR ELECTRICAL WORK LOCATED ON THE SECOND FLOOR. KEYED DEMOLITION NOTES: REMOVE SURFACE MOUNTED LIGHT SWITCH, UNDER CABINET LUMINAIRES, AND ASSOCIATED SURFACE RACEWAYS AND POWER WIRING COMPLETELY. FAQ ITIES ENGINEERING WARNING: IT ISA VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT HIS SEAL AND THE NOTATION 'ALTERED BY' FOLLOWED BY HIS SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. APPROVAL REMOVE EXISTING SURFACE MOUNTED JUNCTION BOX AND PLUGMOLD ON WALLS AS INDICATED. EXISTING BRANCH CIRCUITS (TOTAL OF 2, CKT 4 & CKT 12) FEEDING THE PLUGMOLD SHALL BE REUSED DURING DATE: ENVIRONA EALTH AND SAFETY CONSTRUCTION PHASE. SEE NEW WORK PLAN. .ARCH• CIVIL. ELEC- MECH 0 EXISTING 2' x 2' SURFACE MOUNTED LUMINAIRE TO REMAIN. QEXISTING FIRE ALARM SMOKE DETECTOR TO REMAIN. 0 EXISTING SURFACE MOUNTED PHONE/DATA BOX AND RECEPTACLE TO REMAIN. OEXISTING 2' x 4' SURFACE MOUNTED LUMINAIRE TO REMAIN. 07 EXISTING WALL MOUNTED FIRE ALARM HORN/STROBE TO REMAIN. EXISTING LIGHT SWITCHES) TO REMAIN. Q REMOVE EXISTING CEILING LUMINAIRE WITH CARE (TOTAL OF 9). SAVE THE BEST FOUR LUMINAIRES FOR REUSE. REFER TO NEW WORK PLAN FOR ADDITIONAL INFORMATION. CLEAN THE FIXTURES PRIOR TO THE RE -INSTALLATION WORK. EXISTING ROOM LIGHTING CIRCUITRY SHALL BE SAVED, MODIFIED, AND REUSED. 10 EXISTING SURFACE MOUNTED DIMMING LIGHT SWITCH TO BE REMOVED. EXISTING LIGHTING CIRCUIT SHALL BE SAVED, MODIFIED, AND REUSED. 11 ELECTRICAL CONTRACTOR TO REMOVE EXISTING CABLE TV JACK & CABLE COMPLETELY BACK TO SOURCE. 12 ELECTRICAL CONTRACTOR TO REMOVE PHONE/DATA BOX AND RACEWAYS. CIT TO REMOVE THE PHONE/DATA WIRING. 13 REMOVE EXISTING RECEPTACLE(S) AND ASSOCIATED RACEWAYS. EXISTING POWER CIRCUIT SHALL BE SAVED, MODIFIED, AND REUSED. SEE NEW WORK PLAN. 14 REMOVE EXISTING RECEPTACLE AND ASSOCIATED RACEWAYS & WIRING BACK TO THE RECEPTACLE LOCATED AT COLUMN. 15 EXISTING PHONE/DATA BOX TO BE RELOCATED. NEW LOCATION AS INDICATED. ELECTRICAL CONTRACTOR TO RELOCATE BOX AND RACEWAYS. CIT TO RELOCATE THE WIRING. 16 EXISTING FAN COIL UNIT TO BE REMOVED AND RELOCATED BY OTHERS. ELECTRICAL CONTRACTOR TO DISCONNECT POWER AT THE EXISTING LOCATION AND RECONNECT POWER AT THE NEW LOCATION. PARTIAL THIRD FLOOR ELECTRICAL DEMOLITION PLAN CALE: 4" = 1'-0" NOTES REVISIONS: DATE: 06/05/13— ISSUE FOR CONSTRUCTION CTS z R5 cis © E CO = ©< C!) DATE: June 05, 2013 FACILITY: 2026 DESIGN: H. T DRAWN: hpt PARTIAL THIRD FLOOR ELECTRICAL DEMOLITION PLAN ED -101 P0356 16 15 14 12 11 10 8 7 6 5 2 z2� -1-IL17 Ci 16 15 14 12 10 GENERAL NOTES: 1.0 COORDINATE PHONE/DATA WORK WITH SHAWN WALKER (255-5313). 2.0 PHONE/DATA WORK: BOXES AND RACEWAYS BY ELECTRICAL CONTRACTOR. WIRING, TERMINATIONS, AND FACEPLATES BY CIT. 3.0 ALL FACEPLATES SHALL BE WHITE. ARNING: T IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER. TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT HIS SEAL AND THE NOTATION "ALTERED BY FOLLOWED BY HIS SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. A 4.0 REFER TO ARCHITECTURAL DRAWINGS FOR ELECTRICAL WORK LOCATED ON THE SECOND FLOOR. KEYED NOTES: Q ABOVE NEW BACK SPLASH, PROVIDE WIREMOLD 3000. COLOR SHALL BE IVORY. VERTICAL RUN OF SURFACE RACEWAY SHALL BE WIREMOLD 2400. CIRCUIT RECEPTACLES INDICATED TO (1) EXISTING BRANCH CIRCUIT, CKT 4. SEE NOTE 2, DRAWING ED -101. MONITOR WITH SPEAKERS BY OTHERS. WEBCAM AND ASSOCIATED AV CABLES BY OTHERS. AV INTERFACE BY OTHERS. WEBCAM POWER CORD AND PLUG BY OTHERS. APP VAL FA is IES E IN" RCNG ENVIRONMENTAL HEALTH AND SA DATE: �ftom-e ARCH - CIVIL. ELEC: MECH: "me REVISIONS: DATE: 06/05/13 — ISSUE FOR CONSTRUCTION ELECTRICAL CONTRACTOR TO PROVIDE A CHIEF PROFESSIONAL AV SOLUTION IN -WALL BOX CAT. NO. PAC522 (WWW.CHIEFMFG.COM). INSTALL PER MANUFACTURERS INSTRUCTION. C8 ELECTRICAL CONTRACTOR TO PROVIDE 1" EMT WITH PULLROPE RUNNING FROM NEAREST CIT CABLE TRAY OR JUNCTION BOX TO THE IN -WALL BOX. AT THE IN -WALL BOX, MOUNT A SINGLE GANG BOX TO HOUSE PHONE/DATA WIRING. EXISTING PANEL "W" CIT TO PROVIDE A TOTAL OF TWO PHONE/DATA CABLES. ONE AT THE IN -WALL BOX (FOR THE MONITOR) AND THE OTHER TO RUN DOWN WALL AND TO THE CONFERENCE TABLE. IN -WALL 1" CONDUIT WITH (1) PHONE/DATA CABLE (1) AV CABLE. EXTEND DOWN TO TO FLOOR TO MEET WITH THE EXTRON AVTRAC ROUGH -IN ADAPTER. 1" EMT WITH (1) DEDICATED EXISTING BRANCH CIRCUIT, (2) 12 AWG AND (1) AWG GROUND. SEE ED -101. EXISTING CIRCUIT 42. AT THE IN -WALL BOX, PROVIDE A DUPLEX RECEPTACLE TO SERVE THE MONITOR AND THE WEBCAM. FROM THE RECEPTACLE, EXTEND POWER WIRING IN CONDUIT DOWN TO THE FLOOR TO MEET WITH THE EXTRON AVTRAC ROUGH -IN ADAPTER. CIRCUIT TO EXISTING CIRCUIT 42. SEE ED -101. 13 EXTRON AVTRAC ROUGH -IN ADAPTER, MODEL AVTRAC INST RIA, PART NO. 70-781-01 .EXTRON.COM). SEE FLOOR PLAN FOR CONTINUATION OF WORK. FACEPLATE SHALL BE AVTRAC WALL TRIM PLATE, MODEL AVTRAC INST WTP, PART NO. 70-782-01. 14 SEE DETAIL 1 FOR POWER, PHONE/DATA, AND AV WORK ON THIS WALL. 15 FROM THE EXTRON AVTRAC ROUGH -IN ADAPTER ON FLOOR, PROVIDE A FLOOR MOUNT SURFACE RACEWAY (EXTRON AVTRAC EXTENSION, MODEL AVTRAC 4C EXT, PART NO. 70-645-04). AT THE END OF THE RACEWAY, PROVIDE EXTRON AVTRAC APP ENCLOSURE, MODEL AAP ENCL NO AC, PART NO. 70-801-02. CIT TO EXTEND THE PHONE/DATA CABLE TO RUN INSIDE OF THE RACEWAY TO THE ENCLOSURE. AV CONTRACTOR TO RUN AV CABLE FROM THE AV INTERFACE TO THE ENCLOSURE. INSIDE OF THE ENCLOSURE, ELECTRICAL CONTRACTOR TO PROVIDE EXTRON AVTRAC AC POWER MODULES, MODEL AVTRAC 4US AC/24, PART NO. 70-799-09. THE POWER MODULES HAS 24' PREWIRED CONDUCTORS INSIDE OF A FLEXIBLE CONDUIT. RUN THE CONDUIT INSIDE OF THE FLOOR RACEWAY (SEE NOTE 12). 16 MICROWAVE LOCATED UNDERSIDE OF KITCHEN CABINET BY OTHER. ELECTRICAL CONTRACTOR TO PROVIDE HARDWIRE POWER CONNECTION. CIRCUIT TO EXISTING CKT 12. SEE NOTE 2, DRAWING ED -101. REPLACE EXISTING FACEPLATE WITH A NEW WHITE FACEPLATE. 0 SEE NOTE 13, DRAWING ED -101. MOUNT RECEPTACLE AT 18" AFF TO TOP OF BOX. CEILING a) E CD 1.0 Q C) E E ©. 0 RECEPTACLE BOX PHONE/DATA BOX 158110842.8086111 II 11 11 11 11 1I 11 11 11 sri 1 11 11 II 1I 11 II ■1 1181 BECIXOSIA E al 0 < vJ DATE: June 05, 2013 DESIGN: DRAWN: FLOOR DETAIL 1 2 PARTIAL THIRD FLOOR POWER & PHONE/DATA PLAN J SCALE: 1/4"=1-0" PARTIA THIRD FLOOR POWER & PHONE/DATA P N 4" =1-0" NOTES 15 14 12 11 10 9 8 7 6 5 2 12. E-101 P0356 4u8 1 14 12 11 10 9 7 5 4 3 2 GENERAL NOTES: 1.0 ALL FACEPLATES SHALL BE WHITE. 2.0 REFER TO ARCHITECTURAL DRAWINGS FOR ELECTRICAL WORK LOCATED ON THE SECOND FLOOR. EXISTING PANEL "W" KEYED NOTES: WARNING: T ISA VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY, IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT HIS SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. APPROVAL: DATE: A 01 PROVIDE NEW FCI SMOKE DETECTOR. DETECTOR SHALL MATCH THE EXISTING DETECTOR LOCATED IN ROOM 302. CIRCUIT TO NEAREST EXISTING INITIATION CIRCUITRY. PROVIDE PROGRAMMING AND TESTING OF THE NEW DEVICE AS REQUIRED. Q PROVIDE NEW FCI FIRE ALARM STROBE/HORN COMBO. THE NEW DEVICE SHALL MATCH THE EXISTING DEVICE LOCATED IN ROOM 302. CIRCUIT TO THE SAME NOTIFICATION CIRCUITRY. PROVIDE PROGRAMMING & TESTING OF THE NEW DEVICE AS REQUIRED. MOUNT AT 80" AFF TO THE BOTTOM OF THE LENS. AT 48" AFF TO TOP OF BOX, PROVIDE A 4 -GANG RECESS BOX TO HOUSE (4) LIGHT SWITCHES. DIMMING SWITCH SERVING INCANDESCENT LUMINAIRES SHALL BE WATTSTOPPER AD -1103, DIMMING SWITCH SERVING FLUORESCENT LUMINAIRES SHALL BE WATTSTOPPER AFFE-16A, SINGLE POLE SWITCH SHALL BE HUBBELL HBL1211. CIRCUIT AS INDICATED AND TO EXISTING ROOM LIGHTING CIRCUITRY. Q LUMINAIRE SHALL BE A LIGHTOLIER, LYTEPOINTS 300X SERIES, 375WHX FIXTURE TYPE, CAT. NO. 300MRX. TYPICAL OF 3. CIRCUIT AS INDICATED. F=n„ IE GI NG ENVIRONMENTAL HEALTH AND SAF ARCH CIVIL. ELEC• MECH. REVISIONS: DATE: 06/05/13 - ISSUE FOR CONSTRUCTION O INSTALL RELOCATED LUMINAIRE. CIRCUIT AS INDICATED. • LUMINAIRE SHALL BE A LITECONTROL, CIROS CAT. NO. P -ID -52-4-8-T8- LPD/ELB-1CWQ-PBCWM (4-F32T8). CIRCUIT AS INDICATED. Q LUMINAIRES SHALL BE PHILLIPS COLOR KINETICS, COVE LED LIGHTING. A TYPICAL LUMINAIRE SHALL BE eW COVE QLX POWERCORE 12 INCH, WIDE BEAM ANGLE. LUMINAIRES SHALL BE CONNECTED AND RUN ABOVE THE CEILING STRUCTURE AND CIRCUIT AS INDICATED. THE PURPOSE OF THESE LUMINAIRES IS TO HIGHLIGHT THE FLOAT CEILING. CONTACT BEN HAGAN FROM VERTEX SOLUTIONS (607-734-0701) FOR ADDITIONAL INFORMATION ON THE PRODUCT. • AT 48" AFF TO TOP OF BOX, PROVIDE A WATTSTOPPER DIMMER SWITCH CAT. NO. AD -1103. CIRCUIT SWITCH TO EXISTING ROOM LIGHTING CIRCUITRY AND TO LIGHTING AS INDICATED. WHERE POSSIBLE, DEVICES AND RACEWAYS SHALL BE RECESSED IN WALLS AND CEILINGS. AS FOR SURFACE MOUNT APPLICATION, RACEWAY SHALL BE WIREMOLD 700. COLOR SHALL BE IVORY. Q AT 48" TO TOP OF BOX, PROVIDE A SURFACE MOUNT LIGHT SWITCH, HUBBELL HBL12211. CIRCUIT LIGHT SWITCH TO EXISTING ROOM LIGHTING CIRCUITRY VIA WIREMOLD 700 (IVORY). CIRCUIT TO NEW LIGHTING AS INDICATED. 10 TYPICAL UNDER -CABINET LUMINAIRE SHALL BE PHILLIPS LED, eW PROFILE POWERCORE, 120VAC, WHITE, ITEM NO. 523-000027-76. DATE: June 05, 2013 FACILITY: 2026 DESIGN: H. T N DRAWN: hpt PARTIAL THIRD FLOOR LIGHTING & FIRE ALARM PLAN SCALE; 1/4"=1'-0" 16 14 13 12 10 9 8 1 7 PARTIA THIRD FLOOR LIGHTING FIRE ALAR PLAN 5 6 SCALE: 2 E-102 P0356