HomeMy WebLinkAboutSpace Sciences Building Accessible EntryCORNELL UNIVERSITY SPACE SCIENCES FACILITIES CONTRACTS ACCESSIBLE ENTRY 121 HUMPHREYS SERVICE BUILDING ITHACA, NEW YORK 14853-3701 ADDENDUM NO. 1 May 18, 2016 This Addendum contains changes to the requirements of the Contract Documents and Specifications. Such changes are to be incorporated into the Construction Documents and shall apply to the work with the same meaning and force as if they had been included in the original document. Wherever this Addendum modifies a portion of a paragraph of the specifications or a portion of any Drawing, the remainder of the Paragraph or Drawing shall remain in force. NOTE: Provisions of all Contract Documents apply. INSTRUCTION TO BIDDERS Item 1. Instruction to Bidders, INS-2, Paragraph 7.a. DELETE in its entirety. REPLACE with The project should be started within fifteen (15) calendar days from written authorization to proceed, but work at the site shall start no earlier than July 1, 2016 and shall be completed no later than October 31, 2016. BID FORM Item 2. Bid Form, BF-3, Paragraph 3.a. REMOVE in its entirety. REPLACE with The undersigned agrees, if awarded the Contract, to commence work within fifteen (15) calendar days from written authorization to proceed, but work at the site shall start no earlier than July 1, 2016 and shall be completed no later than October 31, 2016. Item 3. Attached is the Pre-Bid Sign-in Sheet, for reference only. Item 4. RFI Questions and Clarifications See attached RFI Log (Item 1) Attachments: Pre-bid Meeting Sign-in Sheet RFI Log (Item 1) ****END OF ADDENDUM**** SPACE SCIENCES BUILDING ACCESSIBLE ENTRY Date: May 18, 2016 RFI Form RFI/Page/ Response Dwg./Spec./Rep.Section/Design Team Index Number Paragraph/Topic RFI Response 1 General Need clarification on emergency egress path.Contractor is required to designate and maintain an emergency egress path of travel during construction. CB CB CBCB CB CB CB CBCB SPACE SCIENCES 2084 ROCKEFELLER HALL 2014 BIG RED BARN 2040 CLARK HALL 2082 BAILEY HALL 1024 MALOTT HALL 2081A.D. WHITE HOUSE 2006 DRAWING LIST GENERAL T-001 TITLE SHEET ARCHITECTURAL A-000 GENERAL NOTES, SYMBOLOGY, ABBREVIATIONS, & KEY/CODE PLAN A-100 PARTIAL BASEMENT ARCHITECTURAL DEMOLITION AND RENOVATION PLANS A-101 PARTIAL FIRST FLOOR ARCHITECTURAL DEMOLITION AND RENOVATION PLANS A-301 PARTIAL FIRST FLOOR DEMOLITION AND RENOVATION REFLECTED CEILING PLANS ELECTRICAL E-100 PARTIAL BASEMENT ELECTRICAL PLAN E-400 ACCESS CONTROL AND ADA OPERATOR SCHEMATICS MECHANICAL/ELECTRICAL ME-000 SCOPE OF WORK, GENERAL NOTES, SYMBOLOGY, AND ABBREVIATIONS ME-101 FIRST FLOOR MECHANICAL ELECTRICAL PLAN MED-101 PARTIAL FIRST FLOOR MECHANICAL ELECTRICAL DEMO PLAN CORNELLUNIVER S IT Y F O U NDED5681ADCornell UniversityFacilities EngineeringIT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT HIS SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING:Ithaca, New YorkDATE: FACILITY: DESIGN: DRAWN: ARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL: Cornell University Ithaca, New York PROJECT SCOPE Humphreys Service Building; Ithaca, N.Y. Architectural & Structural, Civil & Environmental, Mechanical and Electrical Engineering Facilities Engineering ARCHIVE BAR CODEFE DESIGN 8740618 Space Sciences BuildingT-001 TITLE SHEET jgc 2084 April 27, 2016Space Sciences Building Accessible EntrySpace Sciences Building Accessible Entry LOCATION PLAN - SPACE SCIENCES BUILDING SITE PLAN - SPACE SCIENCES BUILDING N AREA OF WORK The purpose of this project is to make renovations to the existing vestibule space in order to accommodate ADA accessibility into and out of the Space Sciences Building. The work for the new vestibule includes removal of the existing exterior and interior storefront systems and the existing concealed spline ceiling system. The new vestibule spaces will be provided with new aluminum storefront system that includes automatic door operators, card readers, a recessed walk-off entry mat system and new 2’ x 2’ suspended acoustical tile ceiling system. The work also includes removal of the basement interior receiving doors and removal of panic hardware on the exterior door. The exterior door will receive new panic hardware and automatic door operator. Modifications to the electrical, mechanical, and fire protection systems will also be included. REVISIONS 1 3/18/16 ISSUED FOR 50% REVIEW 2 4/18/16 ISSUED FOR 95% REVIEW 3 4/27/16 ISSUED FOR CONSTRUCTION N AREA OF WORK AREA OF WORK IN BASEMENT (BELOW) UP 22 N INTERIOR ELEVATION NORTH ARROW SECTION KEYNOTE - NEW WORK KEYNOTE - DEMOLITION TAG - CASEWORK TAG - FURNISHING TAG - DOOR ROOM NAMEROOM # M-6 0 WALL TYPE AND FIRE RATING 011 999 ROOM DATA ITEM FOR DEMOLITION BREAK LINE DOOR - EXISTING TO REMAIN WALL - EXISTING TO REMAIN WALL - EXISTING TO BE REMOVED TAG - EQUIPMENT TAG - FINISH ELEVATION MARKER B.O. BOTTOM OF BYND BEYOND CLG CEILING DTL DETAIL GWB GYPSUM WALL BOARD MTL METAL O.C. ON CENTER PTD PAINTED RCP REFLECTED CEILING PLAN SIM SIMILAR T.O. TOP OF TYP TYPICAL U.N.O. UNLESS NOTED OTHERWISE U/S UNDERSIDE V.I.F. VERIFY IN FIELD THK THICK WALL - GWB / METAL STUD WALL - CMU HM HOLLOW METAL BATT INSULATION E3 99 XX XXXXX XX O 4 C 7 F1 A-101 2 A-101 1 100CC 100CA 106104 108 110 100SB 111 109 100CB 107105 101 100TA 100J 100TB 102 100SA 100E A-100 2 A-100 1 B00CA B00CB B00UA B00E B00SA B02 B00JA B00T B03A B04 B06 B10 B07 B03 B05 B00UB B00UC B00SB BUILDING CODE SUMMARY 1. OCCUPANCY CLASSIFICATION:GROUP "B" BUSINESS 2. CONSTRUCTION TYPE:1A 3. CLASSIFICATION OF WORK:ALTERATION - LEVEL 2 4. GSF AREA OF ALTERATION:315 GSF 5. BUILDING SPRINKLERS:YES CODE PLAN KEY ALTERATION - LEVEL 2ARCHITECTURAL PATTERNS ABBREVIATIONS SYMBOLS CORNELLUNIVER S IT Y F O U NDED5681ADCornell UniversityFacilities EngineeringIT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT HIS SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING:Ithaca, New YorkDATE: FACILITY: DESIGN: DRAWN:ARCHIVE BAR CODEARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL:Space Sciences BuildingA-000 GENERAL NOTES, SYMBOLOGY, ABBREVIATIONS, & KEY/CODE PLANSpace Sciences Building Accessible EntryJ. COOLBAUGH jgc 2084 April 27, 2016 8740618 GENERAL NOTES 1.0 DESIGN, CONSTRUCTION AND SAFETY SHALL CONFORM TO ALL LOCAL, STATE AND OWNER SPECIFIC CODES, INCLUDING (BUT NOT LIMITED TO) THE "NEW YORK STATE UNIFORM FIRE PROTECTION AND BUILDING CODE", LATEST REVISION, THE NFPA 101 LIFE SAFETY CODE, LATEST REVISION, ANSI A117.1 - LATEST REVISION, OSHA, AND ANY OTHER CODES GOVERNED BY THE JURISDICTION IN WHICH THIS PROJECT IS BEING CONSTRUCTED. 2.0 THIS CONTRACT REQUIRES COMPLETE, FINISHED WORKABLE PROJECT OF THE AREAS INDICATED BY THE CONTRACT DOCUMENTS, AND SHALL INCLUDE ALL MATERIALS AND LABOR NECESSARY TO COMPLETE, REGARDLESS OF WHETHER OR NOT ALL WORK OR EACH ITEM IS SPECIFICALLY INDICATED ON ANY OTHER PORTION OF THE DRAWINGS AND / OR NOTES. 3.0 WHERE MATERIALS REFERENCED ON DRAWINGS, OR NECESSARY TO COMPLETE THE WORK OF THIS CONTRACT ARE NOT SPECIFIED HEREIN, PROVIDE BEST QUALITY MATERIALS. WHERE MATERIALS ARE INTENDED TO MATCH EXISTING, PROVIDE CLOSEST POSSIBLE MATCH, SUBJECT TO OWNER'S APPROVAL. ALL ITEMS AND WORK ON DRAWINGS ARE NEW, UNLESS INDICATED EXISTING. ALL WORK WHICH HAS BEEN DAMAGED SHALL BE REPAIRED OR REPLACED AT NO COST TO THE OWNER. WHERE ITEMS CAN NOT BE REPAIRED TO A "NEW CONDITION", OR WHERE THE STRUCTURAL INTEGRITY HAS BEEN AFFECTED, ITEMS SHALL BE REPLACED AT NO COST TO THE OWNER. 4.0 CONTRACTOR IS RESPONSIBLE TO VERIFY ALL SITE, FIELD AND BUILDING CONDITIONS PRIOR TO SUBMITTING BIDS AND COMMENCING WORK. IF THERE ARE ANY DISCREPANCIES BETWEEN DRAWINGS AND FIELD CONDITIONS, NOTIFY THE PROJECT MANAGER, WHO WILL REQUEST CLARIFICATION FROM THE ARCHITECT/ENGINEER AND PROVIDE CLARIFICATION IN WRITING. 5.0 WHERE EXISTING CONSTRUCTION OR ITEMS HAVE BEEN INFILLED, REMOVED AND / OR DISTURBED FOR INSTALLATION OF NEW WORK, CAUSING THE EXPOSURE OF UNFINISHED AND/OR DAMAGED SURFACES RESULTING SURFACES AND INFILLED SURFACES SHALL BE RECONSTRUCTED WITH MATERIALS TO MATCH FINISHED AREAS. ALL ABANDONED OPENINGS (i.e. DUCT/PIPE REMOVALS, ETC.) AT WALLS, ROOF OR FLOOR TO BE INFILLED SOLID. 6.0 WORK IS REQUIRED IN VARIOUS PORTIONS OF THE FACILITY TO EXECUTE WORK OF OTHER TRADES (i.e. ELECTRICAL, MECHANICAL). ALTHOUGH NOT NECESSARILY SHOWN ON DRAWINGS, WORK IS REQUIRED IN THESE AREAS CONSISTING OF REMOVAL / REPLACEMENTOF CEILINGS, WALLS, FINISHES, PAVEMENT AND OTHER CONSTRUCTION AS NECESSARY TO PERFORM WORK AND RESTORE THESE SPACES OR AREAS TO ORIGINAL CONDITION. 7.0 GENERAL CONTRACTOR IS TO COORDINATE WORK OF ALL TRADES. SCHEDULE WORK PROGRESS THROUGHOUT THE ENTIRE PROJECT TO PREVENT CONFLICTS AND INTERFERENCES. OBTAIN ALL NECESSARY INFORMATION SUCH AS SIZES, LOCATIONS, TEMPLATES, LAYOUT, DIMENSIONS AND ALL OTHER INFORMATION NECESSARY FOR A PROPER AND WELL COORDINATED INSTALLATION. PRIOR TO INSTALLATION OF ITEMS, VERIFY AND CONFIRM WITH EACH CONTRACTOR EXACT LOCATION OF ALL ITEMS 8.0 ALL PENETRATIONS (EXISTING OR NEW )THROUGH FLOORS AND FULL HEIGHT WALLS - IN AREA OF WORK TO BE FIRE STOPPED. ALL GAPS AND JOINTS AT RATED FLOORS, ROOFS AND WALLS TO BE FIRE & SMOKE STOPPED. GAPS AND JOINTS INCLUDE (BUT ARE NOT LIMITED TO) TOP OF WALL TO FLOOR OR ROOF DECK, WALL TO BEAMS, AND CONTROL OR EXPANSION JOINTS. FIRE STOPPING INCLUDES BOTH FORM OR PACKING MATERIAL AND THE FILL, VOID OR CAVITY MATERIAL. 9.0 JOBSITE WILL BE CLEANED DAILY AND DEBRIS REMOVED TO CONTAINERS OR TO VEHICLE WHICH WILL REMOVE DEBRIS FROM CAMPUS. CONTAINERS WILL BE REMOVED AS SOON AS FULL OR WHEN THE PROJECT HAS PROGRESSED TO A POINT THAT A CONTAINER IS NO LONGER REQUIRED. 10.0 CONTRACTOR IS RESPONSIBLE FOR PROTECTING ALL AREAS USED TO BRING SUPPLIES AND EQUIPMENT INTO THE PROJECT AREA. ANYDAMAGE TO AREAS OUTSIDE THE PROJECT AREA INCLUDING BUT NOT LIMITED TO THE LOBBY AND CORRIDOR SHALL BE REPAIRED AT NO COST TO THE OWNER. SCALE: 1/8" = 1'-0"2 FIRST FLOOR KEY/ CODE PLAN SCALE: 1/8" = 1'-0"1 BASEMENT KEY/ CODE PLAN N 0 4 8 16 SCALE: 1/8"=1'-0" N 0 4 8 16 SCALE: 1/8"=1'-0" REVISIONS 1 3/18/16 ISSUED FOR 50% REVIEW 2 4/18/16 ISSUED FOR 95% REVIEW 3 4/27/16 ISSUED FOR CONSTRUCTION F F F 1 B00CA B00UA B00E B00CB B00SA B02 B00JA B00T UP 2 1 B00CA B00CB B00T B00UA B02 B00SA B00E B00JA UP 2 3 B00CA 4 52"1' - 3"6"3' - 5"4"2' - 5"10"V.I.F.8' - 11" +/-V.I.F. 12' - 0" +/- 2"2' - 8" 2" 6' - 0" 2" 2' - 8" 2" IG-1 IG-1 IG-1 IG-1 IG-1 IG-1 IG-1 IG-1 IG-1 IG-1 IG-1 MULLION D1/F1 2"1' - 3"6"3' - 5"4"2' - 5"10"V.I.F.8' - 11" +/-V.I.F. 12' - 0" +/- 2"2' - 8" 2" 6' - 0" 2" 2' - 8" 2" MG-1 MG-1 MG-1 MG-1 MG-1 MG-1 MG-1 MG-1 MG-1 MG-1 MG-1 D2/F2 3 5/8" METAL STUDS AT 16" O.C. ATTACHED TO SLAB ABOVE w/ 5/8" GWB EACH SIDE STOREFRONT SYSTEM FASTENER SIZE AND SPACING BY STOREFRONT MANUFACTURER, SUBMIT CALCULATIONS FOR REVIEW. SHIM AS REQUIRED. BACKER ROD AND SEALANT AS REQUIRED 2X2 ACT BOX HEADER 3 5/8" METAL STUD KICKER AT 48" MAX. ATTACHED TO SLAB ABOVE STOREFRONT SYSTEM SHIM AS REQUIRED BACKER ROD AND SEALANT AS REQUIRED EXISTING BRICK AND BLOCK WALL TO REMAIN MATCH EXISTING SETBACK1' - 10 1/2" +/- V.I.F.EXISTING PRECAST EXISTING BRICK NEW STOREFRONT SYSTEM SHIM AS REQUIRED SEALANT AND BACKER ROD AS REQUIRED STOREFRONT SYSTEM FASTENER SIZE AND SPACING BY STOREFRONT MANUFACTURER, SUBMIT CALCULATIONS FOR REVIEW. SHIM AS REQUIRED. BACKER ROD AND SEALANT AS REQUIRED 2X2 ACT EXISTING PRECAST CONCRETE BOX HEADER 3 5/8" METAL STUD FRAMING AT 16" O.C. & KICKERS AT 48" MAX. ATTACHED TO PRECAST AND SLAB ABOVE CORNELLUNIVER S IT Y F O U NDED5681ADCornell UniversityFacilities EngineeringIT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT HIS SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING:Ithaca, New YorkDATE: FACILITY: DESIGN: DRAWN:ARCHIVE BAR CODEARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL:Space Sciences BuildingA-100 PARTIAL BASEMENT ARCHITECTURAL DEMOLITION AND RENOVATION PLANSSpace Sciences Building Accessible EntryJ. COOLBAUGH jgc 2084 April 27, 2016 8740618SCALE: 1/4" = 1'-0"2 PARTIAL BASEMENT DEMOLITION PLAN SCALE: 1/4" = 1'-0"1 PARTIAL BASEMENT RENOVATION PLAN A-100 KEYED DEMOLITION NOTES 1 REMOVE EXISTING DOORS, RECESSED FLOOR CLOSER, AND TOP PIVOT ONLY. EXISTING HOLLOW METAL FRAME TO REMAIN. 2 REMOVE EXISTING DOOR HARDWARE THIS DOOR ONLY. A-100 KEYED RENOVATION NOTES 1 INFILL HOLLOW METAL FRAME WHERE TOP PIVOT WAS REMOVED. PROVIDE STEEL PLATE, MATCH EXISTING FRAME GAGE. WELD, GRIND, AND FILL HOLES. SAND, PRIME AND PAINT ENTIRE FRAME. COLOR TO MATCH EXISTING FRAME COLOR. 2 PROVIDE STAINLESS STEEL PLATE TO COVER FLOOR WHERE EXISTING RECESSED FLOOR CLOSER WAS REMOVED. SIZE OF PLATE TO BE 3/16" THICK AND LARGE ENOUGH TO COVER THE EXISTING CLOSER AREA. PROVIDE COUNTERSINKING SCREWS TO FASTEN PLATE TO FLOOR. FILL EXISTING HOLE IN FLOOR WITH NON-SHRINK GROUT, MATCH EXISTING FLOOR ELEVATION. 3 PROVIDE NEW ADA OPERATOR AND NEW DOOR HARDWARE. REFER TO HARDWARE SCHEDULE FOR MORE INFORMATION. 4 PROVIDE NEW ADA OPERATOR CONTROL BOLLARD. REFER TO DETAIL 5/A-101 FOR MORE INFORMATION. 5 PROVIDE NEW ADA OPERATOR WALL CONTROL. REFER TO ME-101 FOR MORE INFORMATION. N 0 2 4 8 SCALE: 1/4"=1'-0" N 0 2 4 8 SCALE: 1/4"=1'-0" ARCHITECTURAL GENERAL NOTES 1.0 ALL DIMENSIONS ARE TO BE FIELD VERIFIED PRIOR TO THE START OF CONSTRUCTION. 2.0 THE CONTRACTOR IS RESPONSIBLE TO PROTECT ANY EXISTING FLOORING TO REMAIN DURING DEMOLITION. PROVIDE CONTINUOUS COVERAGE AS APPROVED BY OWNER. # # DOOR SCHEDULE DOOR NUMBER DOOR FRAME DETAILS FIRE RATING GLAZING TYPE HARDWARE GROUP NO.KEYED NOTES SIZE SIZE SIZE TYPE MAT FIN TYPE MAT FIN HEAD JAMB THRESHOLD DOOR WIDTH WIDTH HEIGHT THICKNESSPANELS PANEL WIDTH B00CA (2) 3' - 0" 6' - 0" 7' - 5 1/2" 1 3/4" EX EX EX EX EX EX - - - - - 1 100CC.1 (2) 3' - 0" 6' - 0" 7' - 0" 1 3/4" D1 AL MB F1 AL MB 8/A-100 7/A-100 - - IG-1 2 100CC.2 (2) 3' - 0" 6' - 0" 7' - 0" 1 3/4" D2 AL MB F2 AL MB 5/A-100 6/A-100 - - MG-1 3 SCALE: 1/4" = 1'-0"3 DOOR/ FRAME ELEVATIONS SCALE: 1 1/2" = 1'-0"7 INTERIOR HEAD DETAIL SCALE: 1 1/2" = 1'-0"5 INTERIOR JAMB DETAIL SCALE: 1 1/2" = 1'-0"4 EXTERIOR JAMB DETAIL SCALE: 1 1/2" = 1'-0"6 EXTERIOR HEAD DETAIL REVISIONS 1 3/18/16 ISSUED FOR 50% REVIEW 2 4/18/16 ISSUED FOR 95% REVIEW 3 4/27/16 ISSUED FOR CONSTRUCTION ATTACH STOREFRONT FRAMING TO EXISTING STRUCTURE AS PER MANUFACTURER’S REQUIREMENTS. 1 2 3 7' - 6"2' - 6"7' - 0"2' - 6" 100CC 106104 100CA A-101 3 1 2 1 2 3 4 4 100CC 106104 100CA 100CC.1 100CC.2 2' - 6"7' - 0"2' - 6"7' - 6"6 5 6 A-100 3 A-100 A 4 A-101 1st Floor 0' - 0" 2nd Floor 12' - 3" 100CC.1 12V.I.F.8' - 11" +/-V.I.F. 12' - 0" +/- EXISTING CONCRETE SLAB EXISTING REMAINING STONE FLOORING NEW STAINLESS STEEL WALK OFF MAT. REFER TO SPECIFICATION SECTION 12 48 13. INSTALL AS PER MANUFACTURER'S REQUIREMENTS PROVIDE CONCRETE LEDGE FOR PERIMETER FRAME. DOWEL INTO EXISTING SLAB.3" +/-V.I.F.2 1/2" +/-5 1/2" +/-PROVIDE LIQUID APPLY WATER PROOFING WEDGE ANCHORS AS PER MANUFACTURER'S RECOMMENDATIONS BOLLARD MOUNTING BRACKET CONDUIT, REFER TO DRAWING ME-101 FOR MORE INFORMATION 4' - 0" MIN.MIN. 1' - 0" ADA BOLLARD - INSTALL AS PER MANUFACTURER'S REQUIREMENTS ADA PUSH BUTTON/ CARD READER LOCATION 3' - 6" MIN.CONCRETE SIDEWALK, REFER TO ME-101 FOR REPLACEMENT INFORMATION BACKFILL, MATCH EXISTING GRADE CONCRETE SONOTUBE OR PRECAST UNIT WITH CAST ANCHOR BOLTS. COORDINATE WITH BOLLARD MANUFACTURER FOR BASE PLATE.CORNELLUNIVER S IT Y F O U NDED5681ADCornell UniversityFacilities EngineeringIT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT HIS SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING:Ithaca, New YorkDATE: FACILITY: DESIGN: DRAWN:ARCHIVE BAR CODEARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL:Space Sciences BuildingA-101 PARTIAL FIRST FLOOR ARCHITECTURAL DEMOLITION AND RENOVATION PLANSSpace Sciences Building Accessible EntryJ. COOLBAUGH jgc 2084 April 27, 2016 8740618 SCALE: 1/4" = 1'-0"2 PARTIAL FIRST FLOOR DEMOLITION PLAN SCALE: 1/4" = 1'-0"1 PARTIAL FIRST FLOOR RENOVATION PLAN A-101 KEYED RENOVATION NOTES 1 NEW ALUMINUM STOREFRONT SYSTEM. 2 NEW ALUMINUM DOOR. REFER TO DOOR SCHEDULE FOR MORE INFORMATION. 3 NEW RECESSED STAINLESS STEEL WALK OFF MAT. REFER TO SPECIFICATION SECTION 12 48 13 FOR TYPE. REFER TO DETAIL 4/A-101 FOR MORE INFORMATION. 4 CLEAN BRICK FREE OF DEBRIS AFTER THE REMOVAL OF EXISTING STOREFRONT FRAMING. MATCH EXISTING SURROUNDING BRICK WALL. PATCH ALL EXISTING HOLES IN BRICK WITH GROUT WHERE EXISTING STOREFRONT FRAME WAS REMOVED. COLOR TO MATCH EXISTING BRICK. 5 PROVIDE NEW ADA OPERATOR CONTROL BOLLARD. REFER TO DETAIL 5/A-101 FOR MORE INFORMATION. 6 PROVIDE NEW ADA OPERATOR WALL CONTROL. REFER TO ME-101 FOR MORE INFORMATION. A-101 KEYED DEMOLITION NOTES 1 REMOVE EXISTING ALUMINUM SLIDING DOOR SYSTEM IN ITS ENTIRETY. REMOVE ALL ANCHORS AND SEALANT FROM EXISTING WALLS. TURN DOOR/ FRAME OVER TO OWNER. 2 REMOVE EXISTING STOREFRONT SYSTEM IN ITS ENTIRETY. REMOVE ALL ANCHORS AND SEALANT FROM EXISTING WALLS. TURN DOOR/ FRAME OVER TO OWNER. 3 CUT AND REMOVE EXISTING STONE FLOOR DOWN TO EXISTING STRUCTURAL CONCRETE SLAB. SCALE: 1/4" = 1'-0"3 SOUTH EXTERIOR ELEVATION 0 2 4 8 SCALE: 1/4"=1'-0" N 0 2 4 8 SCALE: 1/4"=1'-0" N ARCHITECTURAL GENERAL NOTES 1.0 ALL DIMENSIONS ARE TO BE FIELD VERIFIED PRIOR TO THE START OF CONSTRUCTION. 2.0 THE CONTRACTOR IS RESPONSIBLE TO PROTECT ANY EXISTING FLOORING TO REMAIN DURING DEMOLITION. PROVIDE CONTINUOUS COVERAGE AS APPROVED BY OWNER. # # REVISIONS 1 3/18/16 ISSUED FOR 50% REVIEW 2 4/18/16 ISSUED FOR 95% REVIEW 3 4/27/16 ISSUED FOR CONSTRUCTION SCALE: 3" = 1'-0"4 WALK OFF MAT DETAIL SCALE: 3/4" = 1'-0"5 ADA BOLLARD DETAIL F1 A1 2 8' - 11" 8' - 11" 1 3 A-301 CUH NEW LIGHT FIXTURES (TYP. OF 6) - REFER TO DRAWING ME-101 FOR MORE INFORMATION. NEW SUPPLY DIFFUSER - REFER TO DRAWING ME-101 FOR MORE INFORMATION. NEW EXIT SIGN - REFER TO DRAWING ME-101 FOR MORE INFORMATION. NEW FIRE ALARM DEVICE - REFER TO DRAWING ME-101 FOR MORE INFORMATION. 104 106 100CA 100CA 100CC COORDINATE CEILING WITH EXISTING SPRINKLER HEAD TO REMAIN. EXISTING SOFFIT TO REMAIN. PATCH AS REQUIRED. PAINT, COLOR TO MATCH EXISTING. NEW 2' x 2' ACOUSTICAL CEILING SYSTEM (8' - 11" +/- A.F.F.) EXISTING CEILING TO REMAIN EXISTING WALL (BEYOND)CORNELLUNIVER S IT Y F O U NDED5681ADCornell UniversityFacilities EngineeringIT IS A VIOLATION OF NEW YORK STATE LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DIRECTION OF A LICENSED ARCHITECT OR ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF THIS DOCUMENT IS ALTERED, THE ALTERING ARCHITECT OR ENGINEER SHALL AFFIX TO SUCH DOCUMENT HIS SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. WARNING:Ithaca, New YorkDATE: FACILITY: DESIGN: DRAWN:ARCHIVE BAR CODEARCH/STRUCT: CIVIL/ENV: ELECTRICAL: MECHANICAL:Space Sciences BuildingA-301 PARTIAL FIRST FLOOR DEMOLITION AND RENOVATION REFLECTED CEILING PLANSSpace Sciences Building Accessible EntryJ. COOLBAUGH jgc 2084 April 27, 2016 8740618SCALE: 1/4" = 1'-0"2 PARTIAL FIRST FLOOR RCP DEMOLITION PLAN SCALE: 1/4" = 1'-0"1 PARTIAL FIRST FLOOR RCP RENOVATION PLAN A-301 KEYED DEMOLITION NOTES 1 REMOVE EXISTING 1'X1' SPLINE CEILING SYSTEM IN ITS ENTIRETY. COORDINATE WITH ELECTRICAL AND MECHANICAL DRAWINGS FOR LIGHT AND GRILL REMOVALS. A-301 KEYED RENOVATION NOTES 1 NEW 2'X2' ACOUSTICAL CEILING SYSTEM 2 PATCH EXISTING SOFFIT WHERE EXISTING SPLINE CEILING SYSTEM WAS REMOVED. MATCH EXISTING SOFFIT FINISH AND COLOR. N 0 2 4 8 SCALE: 1/4"=1'-0" N 0 2 4 8 SCALE: 1/4"=1'-0" # # SCALE: 1 1/2" = 1'-0"3 SOFFIT DETAIL REVISIONS 1 3/18/16 ISSUED FOR 50% REVIEW 2 4/18/16 ISSUED FOR 95% REVIEW 3 4/27/16 ISSUED FOR CONSTRUCTION FFFEMAMRBARBCLBEB123416EXISTING EMTELEPHONEEXISTINGCONCRETE PADEXISTINGCHASE5EXISTING GENERATOREXHAUST DUCT67FASTEN PVC TO INSIDEFACE OF CONCRETE WALLEXISTINGPAVEMENT89EXISTING STEELBOLLARDSEXISTING ASPHALT1415REFER TO DETAIL #1/ME-101FOR CONTINUATION10ACCESSCONTROLPANELEXISTING DATAROOM ACCESSCONTROL PANEL12B02 B04B06B00SAB00EB00UAB03B03AB00TB00JAB00CBB00CA11EXISTING 2-POSTDATA RACKPROVIDE METAL SURFACE RACEWAY TOABOVE FINISHED CEILING AND 3/4" EMTTO ADA OPERATOR FOR ADA CONTROLSTATION WIRING3/4" EMT ABOVE FINISHED CEILINGFOR ADA OPERATOR POWER13DB1718EXISTING SIMPLEXCONVENTIONAL FIREALARM CONTROL PANELCORNELLUNIVERSITYFOUNDED5681ADCornell UniversityFacilities EngineeringIT IS A VIOLATION OF NEW YORK STATE LAW FORANY PERSON, UNLESS ACTING UNDER THEDIRECTION OF A LICENSED ARCHITECT ORENGINEER, TO ALTER THIS DOCUMENT IN ANYWAY. IF THIS DOCUMENT IS ALTERED, THEALTERING ARCHITECT OR ENGINEER SHALL AFFIXTO SUCH DOCUMENT HIS SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISSIGNATURE, THE DATE OF SUCH ALTERATION,AND A SPECIFIC DESCRIPTION OF THEALTERATION.WARNING:Ithaca, New YorkDATE:FACILITY:DESIGN:DRAWN:ARCHIVE BAR CODEARCH/STRUCT:CIVIL/ENV:ELECTRICAL:MECHANICAL:Space Sciences BuildingE-100PARTIALBASEMENTELECTRICAL PLANSpace Sciences Building Accessible EntryC. WAYMANcmw2084April 18, 20168740618SCALE: 1/4" = 1'-0"1PARTIAL BASEMENT POWER PLAN024 8SCALE: 1/4"=1'-0"NME-100 KEYED CONSTRUCTION NOTES1 PROVIDE FIRE ALARM MANUAL PULL STATION WITH SURFACE MOUNT BOX ANDSURFACE RACEWAY TO ABOVE FINISHED CEILING. INSTALL HANDLE AT 48" AFF.CIRCUIT WITH 2#14 FPLP ABOVE FINISHED CEILING TO EXISTING SLC IN CORRIDORB00CB.2 PROVIDE EMERGENCY LIGHTING BATTERY UNIT AND CIRCUIT TO THE UNSWITCHEDPHASE OF CORRIDOR B00CB LIGHTING BRANCH CIRCUIT FOR POWER SENSING ANDCHARGING. INSTALL TOP OF UNIT FLUSH WITH FINISHED CEILING.3 PROVIDE REMOTE, DUAL HEAD EMERGENCY LIGHT AND CIRCUIT TO THE EMERGENCYLIGHTING BATTERY UNIT WITH 2#12+GND MC CABLE. INSTALL CENTER OF UNIT AT7'-6" AFG. CONCREAL BRANCH CIRCUITRY WITHIN CHASE. PATCH EXTERIOR WALLPENETRATION.4 PROVIDE 2#12, 1#12G, 3/4" EMT FROM ADA OPERATOR TO PANEL EB IN CORRIDORB00CB. CONCEAL BRANCH CIRCUITRY ABOVE FINISHED CEILING.5 INSTALL ADA OPERATOR CONTROL STATION AT PEDESTAL. PROVIDE AN ACCESSCONTROL CARD READER AND INSTALL ON PEDESTAL.6 SAWCUT AND REMOVE ASPHALT AT LEAST 1'-0" BEYOND EACH SIDE OF TRENCH,EXCAVATE 18" BELOW GRADE, AND PROVIDE 1" PVC FROM PEDESTAL TO 6"x6" J-BOX(KEYED NOTE #9). STUB CONDUIT UP WITHIN PEDESTAL. BACKFILL EXCAVATIONWITH NYSDOT TYPE 4 GRAVEL AS NEEDED. PROVIDE NYSDOT TYPE 7 TOP HOT MIXASPHALT TO MATCH EXISTING ASPHALT THICKNESS. COMPACT ASPHALT WITHVIBRATORY TAMP TO MATCH EXISTING ASPHALT ELEVATION.7 COREDRILL 12" THICK, REINFORCED CONCRETE CURB AS SHOWN. TRANSITION TO 1"RGS AT CURB AND EXPOSED TO 6"x6" J-BOX (KEYED NOTE #9). MORTAR CURBPENETRATIONS AFTER RGS INSTALLATION.8 COREDRILL EXTERIOR WALL (BRICK ON EXTERIOR AND CMU ON INTERIOR) ANDPROVIDE 1" RGS BETWEEN OUTDOOR AND INTERIOR J-BOXES. SEAL WALLPENETRATIONS.9 PROVIDE A NEMA 3R 6"x6" PVC J-BOX ON EXTERIOR AND A NEMA 1 6"x6" GALVANIZEDJ-BOX ON INTERIOR.10 PROVIDE ACCESS CONTROL PANEL.11 PROVIDE A 4"x4" J-BOX NEXT TO ACCESS CONTROL PANEL WITH 3/4" BUSHED EMT TOCEILING. PROVIDE A CAT6 CABLE FROM PATCH PANEL IN THIS ROOM. PROVIDECOVERPLATE, TERMINATIONS, AND CABLE TESTING.12 PROVIDE 3/4" EMT ABOVE FINISHED CEILINGS FOR ACCESS CONTROL WIRING.13 PROVIDE 1-HOUR RATED FIRESTOP PENETRATIONS INTO CORRIDOR.14 PROVIDE A 6"x6" NEMA 1 GALVANIZED J-BOX FOR ACCESS CONTROL WIRING TOFIRST FLOOR ADA OPERATOR.15 COREDRILL CONCRETE FOUNDATION WALL AND TRANSITION TO 3/4" RGS THRUWALL. PROVIDE A LINK-SEAL AT WALL PENETRATION.16 EXISTING GE TYPE NLTQ EMERGENCY PANEL: PROVIDE A 20A/1-POLE CIRCUITBREAKER AT POSITION #15 FOR ACCESS CONTROL PANEL AND A 20A/1-POLE CIRCUITBREAKER AT POSITION #17 FOR BASEMENT ADA DOOR OPERATOR. CIRCUITBREAKERS SHALL BE UL LISTED COMPATIBLE. MATCH AIC RATING OF EXISTINGBREAKERS. MODIFY PANELBOARD SCHEDULE ACCORDINGLY.17 PROVIDE A FIRE ALARM ADDRESSABLE MODULE ABOVE THE FINISHED CEILING FORTHE ADA OPERATOR FIRE ALARM SHUNT. CIRCUIT WITH 2#14 FPLP TO NEAREST SLCIN CORRIDOR B00CB. COORDINATE INSTALLATION WITH THE ADA OPERATORMANUFACTURER. DOOR SHALL RELEASE UPON FIRE ALARM ACTIVATION.18 PROVIDE ALL NECESSARY ACCESS CONTROL TERMINATIONS AT DOOR FOR POWERTO ELECTRIC HINGES, REQUEST-TO-EXIT SENSOR, AND DOOR CONTACTS.#REVISIONS1 3/18/16 ISSUED FOR REVIEW2 4/18/16 ISSUED FOR 95% REVIEW3 4/27/16 ISSUED FOR CONSTRUCTION ACCESSCONTROLPANELBASEMENTFIRST FLOORCARDREADERB03A6#22 STANLEY 2S22062GN54#18 STANLEY 2U18042BK52#18 STANLEY 2S18022RD5120V POWERCAT6 DATANOTE:PROVIDE A COMPLETE ACCESS CONTROL SYSTEM, INCLUDING HEADEND,CARD READERS, CONDUIT AND WIRE, AND PROGRAMMING. REFER TO ANDCOMPLY WITH CORNELL DESIGN STANDARD 281316.DOORHARDWAREDOORCONTACTSJBCARDREADER6#22 STANLEY 2S22062GN54#18 STANLEY 2U18042BK52#18 STANLEY 2S18022RD5DOORHARDWAREDOORCONTACTSJBADA DOORAUTO OPERATORCONTROLPANEL2#18 (TYP BETWEENCONTROL BUTTONSAND OPERATOR CONTROLPANEL)1617131422232#14 FPLP TO FIREALARM ADDRESSABLEMODULE (FIRE ALARMSHUNT)INTERIORADA CONTROLBUTTONEXTERIORADA CONTROLBUTTONMPAM RELAYCRASHBARLOCKSETCARD ACCESSSTRIKEADA OPERATORSTRIKE RELAY0V24VCARD ACCESS24V POWER120V POWERCORNELLUNIVERSITYFOUNDED5681ADCornell UniversityFacilities EngineeringIT IS A VIOLATION OF NEW YORK STATE LAW FORANY PERSON, UNLESS ACTING UNDER THEDIRECTION OF A LICENSED ARCHITECT ORENGINEER, TO ALTER THIS DOCUMENT IN ANYWAY. IF THIS DOCUMENT IS ALTERED, THEALTERING ARCHITECT OR ENGINEER SHALL AFFIXTO SUCH DOCUMENT HIS SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISSIGNATURE, THE DATE OF SUCH ALTERATION,AND A SPECIFIC DESCRIPTION OF THEALTERATION.WARNING:Ithaca, New YorkDATE:FACILITY:DESIGN:DRAWN:ARCHIVE BAR CODEARCH/STRUCT:CIVIL/ENV:ELECTRICAL:MECHANICAL:Space Sciences BuildingE-400ACCESS CONTROLAND ADAOPERATORSCHEMATICSSpace Sciences Building Accessible EntryC. WAYMANcmw2084April 18, 20168740618REVISIONS1 3/18/16 ISSUED FOR REVIEW2 4/18/16 ISSUED FOR 95% REVIEW3 4/27/16 ISSUED FOR CONSTRUCTIONSCALE: NO SCALE1ACCESS CONTROL SCHEMATIC DIAGRAMSCALE: NO SCALE2TYPICAL ADA MOTORIZED OPERATOR SCHEMATIC DIAGRAM VALUESGTTETEGTTTG"NAME" (E)VALUETAG NO.TAG NO.TAG NO.?"X?"XXX"NAME"EXISTING PIPINGDEMOLITION WORKEXISTING EQUIPMENTPIPING TO BE REMOVEDPNEUMATIC THERMOSTATPNEUMATIC THERMOSTATPLEASE NOTE: IF EXISTING AN "E" IS ADDEDW/ GUARDTEMPERATURE SENSORELECTRIC THERMOSTATELECTRIC THERMOSTATW/ GUARDPNEUMATIC THERMOSTATW/ GUARDEQUIPMENT TAG (NON-MOTORIZED)EQUIPMENT TAG (MOTORIZED)DUCT UP (SUPPLY)CFM, GPM, CAPACITYNEW EQUIPMENTREGISTER, GRILLE, DIFFUSERCFM, GPM, CAPACITYNECK SIZEAFF ABOVE FINISHED FLOORPOINT OF CONNECTIONPOINT OF DISCONNECTIONTO BE REMOVEDTO BE REMAINCORNELLUNIVERSITYFOUNDED5681ADCornell UniversityFacilities EngineeringIT IS A VIOLATION OF NEW YORK STATE LAW FORANY PERSON, UNLESS ACTING UNDER THEDIRECTION OF A LICENSED ARCHITECT ORENGINEER, TO ALTER THIS DOCUMENT IN ANYWAY. IF THIS DOCUMENT IS ALTERED, THEALTERING ARCHITECT OR ENGINEER SHALL AFFIXTO SUCH DOCUMENT HIS SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISSIGNATURE, THE DATE OF SUCH ALTERATION,AND A SPECIFIC DESCRIPTION OF THEALTERATION.WARNING:Ithaca, New YorkDATE:FACILITY:DESIGN:DRAWN:ARCHIVE BAR CODEARCH/STRUCT:CIVIL/ENV:ELECTRICAL:MECHANICAL:Space Sciences BuildingME-000SCOPE OF WORK,GENERAL NOTES,SYMBOLOGY, ANDABBREVIATIONSSpace Sciences Building Accessible EntryC. WAYMANcmw2084April 18, 20168740618ELECTRICAL SYMBOLOGYMECHANICAL ABBREVIATIONS & SYMBOLOGYSCOPE OF WORKGENERAL NOTES1.0PROVIDE POWER TO ADA DOOR OPERATORS.2.0PROVIDE INTERIOR, EXTERIOR, AND EMERGENCY EGRESS LIGHTING.3.0PROVIDE AN ACCESS CONTROL SYSTEM: INCLUDING HEADEND,CARD READERS, DATA PORT, WIRING, PROGRAMMING, AND TESTING.3.0INTEGRATE ACCESS CONTROL SYSTEM WITH ADA DOOR OPERATORSTO PREVENT MOTORIZED DOORS FROM OPERATING WHEN THERE IS NOVALID CARD READ.4.0PROVIDE FIRE ALARM EQUIPMENT.5.0REMOVE AND REPLACE CONCRETE WALKWAY ON FIRST FLOOR FOR ADA PEDESTAL,AND TRENCH AND RESTORE PAVEMENT AT BASEMENT FOR ADA PEDESTAL.1.0ELECTRICAL SCHEMATICS INDICATED ON CONTRACT DOCUMENTS AREDIAGRAMMATIC. IT IS NOT THE INTENT TO SHOW EXACT OR MOSTEFFICIENT ROUTING. VERIFY ALL DIMENSIONS AND FIELD CONDITIONSON SITE. ANY CONFLICTS BETWEEN CONSTRUCTION DOCUMENTS ANDFIELD CONDITIONS SHALL BE BROUGHT TO CORNELL'S PROJECT MANAGERFOR RESOLUTION BEFORE WORK PROCEEDS.2.0ASSURE PUBLIC AND WORKER SAFETY AT ALL TIMES. PROTECT ADJOININGAREAS FROM DAMAGE AND DUST. REMOVE ALL DEBRIS FROM SITE ANDDISPOSE OF WASTE MATERIAL IN A SAFE MANNER. KEEP THE PREMISESFREE OF DEBRIS FROM THE EXECUTION OF WORK. DELIVER A FINALPRODUCT THAT IS CLEAN AND OPERABLE.3.0FIRE STOP ELECTRICAL PENETRATIONS THROUGH FIRE RATED WALLSAND/OR FLOORS WITH MATERIAL EQUAL IN RATING TO THE CONSTRUCTIONOF THE MATERIAL PENETRATED.4.0WORK SHALL BE COMPLETED AS SPECIFIED AND INDICATED ON CONTRACTDOCUMENTS. ANY SUGGESTED ALTERNATE MANUFACTURER OR METHODOF INSTALLATION SHALL BE SUBMITTED TO PROJECT ENGINEER FORAPPROVAL PRIOR TO ORDERING ANY MATERIALS OR COMMENCINGEXECUTION OF WORK.5.0GROUNDING SHALL BE IN STRICT ACCORDANCE WITH NEC ARTICLE 250.PROVIDE EQUIPMENT GROUND CONDUCTOR WITH EACH BRANCH CIRCUITINDICATED ON CONTRACT DOCUMENTS. EQUIPMENT GROUND CONDUCTORSHALL BE ROUTED WITH ASSOCIATED PHASE CONDUCTORS.6.0PROVIDE A NEW TYPED PANELBOARD DIRECTORY FOR EACH PANELBOARD.LABEL ALL NEW DEVICE FACEPLATES WITH SOURCE AND CIRCUIT NUMBER.PROVIDE PERMANENT LABEL ON SWITCHING DEVICES INDICATINGEQUIPMENT SERVICE AND INVENTORY NUMBERS. COORDINATE EQUIPMENTINVENTORY NUMBERS WITH CORNELL UNIVERSITY'S MECHANICAL SHOP,255-8667.7.0CIRCUITS RATED 20-AMP, 120 VOLT SHALL CONTAIN SEPARATE NEUTRALCONDUCTORS.8.0CONDUCTORS SHALL BE A MINIMUM OF 12AWG, STRANDED COPPER, 600VAC, 90DEGREE C, TYPE THHN/THWN FOR DRY AREAS AND XHHW/THWN-2 FOR WETAREAS.9.0CONDUITS SHALL BE A MINIMUM OF 3/4 INCHES DIAMETER. CONDUITSSHALL BE ELECTRICAL METALLIC TUBING (EMT) AND SURFACE MOUNTEDUNLESS NOTED OTHERWISE.10.0AIC RATING OF NEW CIRCUIT BREAKERS SHALL MATCH RATING OFRESPECTIVE PANELBOARD. SIZE AS INDICATED.11.0PROVIDE PULL STRING THROUGH NEW CONDUIT AND BOXES. PROVIDESUPPORT HANGERS FOR CONDUIT AS NEEDED.12.0INSTALL RACEWAY SYSTEMS ENSURING PROPER ACCESS TO EQUIPMENTAND DEVICES AND WITH SUFFICIENT SPACE TO PERFORM ROUTINEMAINTENANCE AND REPAIR. RACEWAYS THAT ARE NOT INSTALLED WITHTHIS REQUIREMENT IN MIND SHALL BE RELOCATED AT NO EXPENSE TOTHE UNIVERSITY UNTIL DEFICIENCIES ARE CORRECTED.99F10A103D16A103D16A103F10A103GENERAL SYMBOL LEGEND22XXXXXXXXXXXXXXXXXXXXXPOINT OF CONNECTION TO EXISTING WORK TO REMAINPOINT OF DEMOLITION TO EXISTING WORK TO REMAINCONDUIT DROP OR RISE AS INDICATEDCIRCUITAAAAAIR BREAK INTERRUPTER SWITCHFUSED DISCONNECT SWITCHTHERMAL MAGNETIC MOLDED CASE CIRCUIT BREAKERCTCURRENT TRANSFORMERPTPOTENTIAL TRANSFORMERMOV TYPE LIGHTNING ARRESTOR SIZE AND CLASSAS INDICATEDMETER/INSTRUMENT LETTER INDICATES FUNCTIONA - AMMETERPF - POWER FACTOR METERS - SYNCHROSCOPEVH - VARHOUR METERV - VOLT METERVAR- VARMETERW - WATTMETERWH - WATTHOUR METERWHD- WATTHOUR METER W/DEMAND REGISTERCIRCUIT MONITORMETER/INSTRUMENT SWITCH LETTERS INDICATEFUNCTION:AS - AMMETER SWITCHVS - VOLTMETER SWITCHWS - WATTMETER SWITCHASAND TYPETRANSFORMER, REFER TO SCHEDULE FOR SIZETGENERATOR SETGGROUND CONNECTIONTOP OF ROD 2'0" BELOW FINISHED GRADE UNLESSWELDS ONLY.MOLDED FUSION "T" EXOTHERMIC WELDS FOR GRIDCONNECTION , UNDERGROUND WORK.GROUND TERMINATION TO EQUIPMENT. (FRAME,GROUND BUS, TRANSFORMER NEUTRAL)6'-0" COIL FOR FUTURE USE.No. 4/0 STRANDED BARE COPPER PIGTAIL. MINIMUMDRAWOUT DEVICE1200AT1600AFCHARACTERISTICS INDICATED BY SUBSCRIPTS:CIRCUIT BREAKER SOLID STATE TRIPAT - TRIP COIL AMPERE RATINGAF - FRAME SIZE AMPERE RATINGCL - CURRENT LIMITINGL - LONG TIME TRIPS - SHORT TIME TRIPI - INSTANT ANEOUS TRIPG - GROUND FAULT TRIPSH - SHUNT TRIPSSTLSIGTRANSFER SWITCH, RATING ASINDICATED.ATS = AUTOMATIC10'-0" x 5/8" DIAMETER, COPPER CLAD GROUND ROD.CMSDFSTSPSSDBTSDBR135HDDDFFHDNFEMH190ELECTRICAL ONE-LINE SYMBOLS GENERAL ELECTRICAL SYMBOLSFIRE ALARM SYMBOLSSECURITY SYMBOLSLIGHTING SYMBOLSENLARGED DETAILEXTERIOR ELEVATIONINTERIOR ELEVATIONKEYNOTE DEMOLITIONKEYNOTE NEW WORKMATCH LINENORTH ARROWSECTIONEXISTING WORK TO REMAIN (GRAYSCALE)REMOVAL WORK (DASHED)NEW WORK (BOLD)THERMOSTATTSMOKE DETECTOR PHOTOELECTRONIC SENSORTRANSMITTER BEAM DETECTORRECEIVER BEAM DETECTORDUCT DETECTORTAMPER SWITCHLOW AIR SWITCHFLOW PRESSURE SWITCHHEAT DETECTOR 135 F OR 200 F FIXED TEMP SENSORFIRE ALARM PULL STATIONFIRE ALARM STROBE/HORN COMBOFIRE ALARM STROBE ONLYFIRE ALARM HORN ONLYP-1A12DRAWING REMOVAL KEYED NOTE INDICATORDRAWING CONSTRUCTION KEYED NOTE INDICATORPANELBOARD.LP-1JUNCTION BOX.SPECIAL PURPOSE RECEPTACLE DEVICE. PROVIDE SINGLEDEVICE WITH NEMA RATING AS INDICATED AND MATCHINGCOVER PLATE.MOTOR, NUMBER INSIDE SYMBOL INDICATES HORSEPOWER.5MANUAL MOTOR STARTER, SURFACE MOUNTED UNLESSOTHERWISE INDICATED.DISCONNECT SWITCH.COMBINATION STARTER.METERING DEVICE, TYPE INDICATED ON CONTRACT DOCUMENTS.THREE SPEED SWITCHTWO DUPLEX CONVENIENCE RECEPTACLES MOUNTED ON A SINGLEGANG PLATE.WWIRE MOLD SURFACE RACEWAYVARIABLE FREQUENCY DRIVE.X X X X X X XPLUGMOLDDUPLEX CONVENIENCE RECEPTACLE, GF = GROUND FAULTINTERRUPTER PROTECTION.BRANCH CIRCUITRY TO POWER RECEPTACLE DEVICE(S) IS NOTINDICATED ON THE CONTRACT DOCUMENTS. THE ALPHA-NUMERICTEXT ADJACENT TO THE DEVICE SYMBOL INDICATES THE PANELAND CIRCUIT NUMBER IT'S FED FROM. FOR EXAMPLE: P-1A/12INDICATES THAT THE DEVICE IS FED FROM PANEL P-1A, CIRCUIT #12.PROVIDE CIRCUITRY TO DEVICE(S) AS FOLLOWS: DEVICES INDICATEDWITH THE SAME CIRCUIT NUMBER SHALL BE CIRCUITED TOGETHERTO A 20AMP/1-POLE CIRCUIT BREAKER USING 2#12, 1#12G, IN 3/4 INCHEMT CONDUIT UNLESS INDICATED OTHERWISE. A MAXIMUM OF FOUR20 AMP, SINGLE PHASE BRANCH CIRCUITS CONSISTING OF(8#12, 1#12G) SHALL BE PERMITTED IN ONE INCH EMT CONDUIT.SINGLE POLE SWITCH.LIGHTING FIXTURE. FA = FIXTURE TYPE, REFER TOSPECIFICATIONS. a = CONTROL BY WALL SWITCH MARKEDSAME. EM = EMERGENCY POWER SOURCE.SINGLE POLE SWITCHES GANGED ON A SINGLE PLATE.MARKED SAME AS ABOVE.SECURITY SYSTEM PANIC BUTTONSSECURITY SYSTEM DOOR SWITCHTRACK LIGHTS.LIGHTS.SURFACE MOUNTED OR RECESSED DOWN LIGHTS.LIGHTING DIMMER.EXIT LIGHT.RAIMAGNETIC DOOR HOLDERRTSREMOTE TEST SWITCH/STATIONREMOTE ALARM INDICATORTHREE OR FOUR WAY SWITCH.OCCUPANCY SENSOR. "C" INDICATES CEILING MOUNTED."W" INDICATES WALL MOUNTED.OSCOMBINATION LIGHT SWITCH & OCCUPANCY SENSOR.AUXILIARY POWER SUPPLY.GENERATOR REMOTE ANNUNCIATOREMERGENCY WALLPACK LUMINAIREEMERGENCY/EXIT COMBO WALLPACK LUMINAIRECOMMUNICATION OUTLET. P/D INDICATES PHONE/DATA.WP INDICATES WALL PHONE OUTLET.DELECTRIC STRIKEHARDWIRED EQUIPMENT CONNECTIONP-1A12HOMERUN TO PANEL P-1A, CIRCUIT #12. FED FROM 20A - 1P BREAKERIS INTENDED UNLESS NOTED OTHERWISE. RUN GREEN WIRE GROUNDFOR ALL CIRCUITS. PROVIDE ONE GROUND PER CIRCUIT.SSS43FA EMaFB EMaSSOSSPBDSESFFAPSAP-1A12P-1A12JGFIM5-20RSVFDGRAS3-SPDEMERGENCY POWER OFF (EPO)GROUND ROD ELECTRODEEMELECTRICAL ABBREVIATIONSAFF ABOVE FINISHED FLOORAFG ABOVE FINISHED GRADEAFI ARC FAULT CIRCUIT INTERRUPTERAMM ADDRESSABLE MONITOR MODULEAOM ADDRESSABLE OUTPUT MODULEARB AUXILIARY RELAY BOARDATS AUTOMATIC TRANSFER SWITCHBKR BREAKERCCONDUITCD CANDELACKT CIRCUITCR CONTROL RELAYEC ELECTRICAL CONTRACTOREMT ELECTRICAL METALLIC TUBINGEPO EMERGENCY POWER OFF STATIONFAAP FIRE ALARM ANNUNCIATOR PANELFACP FIRE ALARM CONTROL PANELFSD FAN SHUT DOWNGAA GENERATOR ALARM ANNUNCIATORGFI GROUND FAULT CIRCUIT INTERRUPTERGND GROUNDHP HORSEPOWERKW KILOWATTLC LIGHTING CONTACTORLFMC LIQUID TIGHT FLEXIBLE METALLIC CONDUITLTG LIGHTINGMCB MAIN CIRCUIT BREAKERMLO MAIN LUG ONLYMTS MANUAL TRANSFER SWITCHNAC NOTIFICATION APPLIANCE PANELNIC NOT IN CONTRACTOE OVERHEAD ELECTRICPC PHOTOCELLPM PLUGMOLDPP POWER PANELPVC POLYVINYL CHLORIDERGS RIGID GALVANIZED STEELST SHUNT TRIPTM THERMAL MAGNETICTSP TWISTED SHIELDED PAIRTYP TYPICALUE UNDERGROUND ELECTRICUOI UNLESS OTHERWISE INDICATEDUPS UNINTERRUPTIBLE POWER SUPPLYVVOLTVA VOLT AMPSWP WATERPROOFREVISIONS1 3/18/16 ISSUED FOR REVIEW2 4/18/16 ISSUED FOR 95% REVIEW3 4/27/16 ISSUED FOR CONSTRUCTIONLUMINAIRE SCHEDULETYPE DESCRIPTION MOUNTING SIZE MANUFACTURER MODEL NO. VOLTAGE BALLAST LAMPS WATTAGE FINISHA LED DOWNLIGHT RECESSED 6" DIA. GOTHAM LIGHTING EVO-35/35-6WR-MWD-LD-MVOLT 120/277 LED LED 48.1 WHITEB EMERGENCY BATTERY LIGHT WALL 13"x7" LITHONIA ELM627-H1206 120/277 - 12W HALO 27 WHITEC EXIT SIGN UNIVERSAL 12"x7.5" SIMKAR SLEDBRW-SD 120/277 LED LED 3 WHITED EM REMOTE WALL 8.5"x5.75" LITHONIA ELA-B-T-QWP-L0309 12V - - 3 BLACKCSCONTROL STATIONELECTRICAL ABBREVIATIONS SSFFFFAM1L1WL1E23844AAAAAA9104100CA106100CA100CCEXISTING CABINET UNITHEATER (DISCONNECTABOVE CEILING)1110105 107109100CB111100SB110108102100SA100TA100J101100E100TBE1CEXISTING EMERGENCYLIGHT (EXIT DISCHARGE)CS75REFER TO DETAIL #1/E-100FOR CONTINUATION6121314151530cd1617CORNELLUNIVERSITYFOUNDED5681ADCornell UniversityFacilities EngineeringIT IS A VIOLATION OF NEW YORK STATE LAW FORANY PERSON, UNLESS ACTING UNDER THEDIRECTION OF A LICENSED ARCHITECT ORENGINEER, TO ALTER THIS DOCUMENT IN ANYWAY. IF THIS DOCUMENT IS ALTERED, THEALTERING ARCHITECT OR ENGINEER SHALL AFFIXTO SUCH DOCUMENT HIS SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISSIGNATURE, THE DATE OF SUCH ALTERATION,AND A SPECIFIC DESCRIPTION OF THEALTERATION.WARNING:Ithaca, New YorkDATE:FACILITY:DESIGN:DRAWN:ARCHIVE BAR CODEARCH/STRUCT:CIVIL/ENV:ELECTRICAL:MECHANICAL:Space Sciences BuildingME-101FIRST FLOORMECHANICALELECTRICAL PLANSpace Sciences Building Accessible EntryC. WAYMANcmw2084April 18, 20168740618REVISIONS1 3/18/16 ISSUED FOR REVIEW2 4/18/16 ISSUED FOR 95% REVIEW3 4/27/16 ISSUED FOR CONSTRUCTIONSCALE: 3/16" = 1'-0"1FIRST FLOOR MECHANICAL ELECTRICAL PLAN#ME-101 KEYED CONSTRUCTION NOTES1 CIRCUIT EXIT SIGN TO EXISTING EXIT SIGN BRANCH CIRCUIT.2 PROVIDE FIRE ALARM MANUAL PULL STATION WITH SURFACE MOUNT BOX ANDSURFACE RACEWAY TO ABOVE FINISHED CEILING. INSTALL HANDLE AT 48" AFF.CIRCUIT WITH 2#14 FPLP ABOVE FINISHED CEILING TO EXISTING SLC IN CORRIDOR100CA.3 PROVIDE FIRE ALARM A/V NOTIFICATION APPLIANCE WITH SURFACE MOUNT BOX ANDSURFACE RACEWAY TO ABOVE FINISHED CEILING. INSTALL BOTTOM OF LENS AT 80"AFF. CIRCUIT WITH 2#14 FPLP ABOVE FINISHED CEILING TO EXISTING SLC INCORRIDOR 100CA.4 PROVIDE 2#12, 1#12G, 3/4" EMT FROM ADA OPERATOR TO PANEL E1 IN ROOM 109.CONCEAL BRANCH CIRCUITRY ABOVE FINISHED CEILING.5 INSTALL ADA OPERATOR CONTROL STATION AT PEDESTAL. PROVIDE AN ACCESSCONTROL CARD READER AND INSTALL ON PEDESTAL.6 TRENCH 18" BELOW GRADE AND PROVIDE 1" PVC FROM PEDESTAL TO 6"x6" J-BOX INBASEMENT ROOM B06. STUB CONDUIT UP WITHIN PEDESTAL.7 PROVIDE A 4"x4" SURFACE MOUNT J-BOX WITH SURFACE RACEWAY TO ABOVEFINISHED CEILING. INSTALL ADA OPERATOR AT 48" AFF TO CENTER OF OPERATOR.8 REPLACE LIGHT SWITCHES AND PROVIDE A 2-GANG COVERPLATE.9 PROVIDE RECESSED, LED DOWNLIGHTS AS SHOWN. MODIFY/EXTEND EXISTINGLIGHTING BRANCH CIRCUITRY.10 PROVIDE 24"X24" LAY-IN SUPPLY DIFFUSER (B.O.D. TITUS TDC, 14"X10" RECTANGULARNECK, STEEL) AND VOLUME DAMPER (B.O.D. 14"X10" GREENHECK MBD-15, OPPOSEDBLADE). EXTEND EXISTING 14"X10" SUPPLY DUCT AS NECESSARY TO COMPLETECONNECTION TO NEW SUPPLY DIFFUSER. VOLUME DAMPER SHALL BE INSTALLED ATLEAST 5'-0" FROM THE DIFFUSER. BALANCE SUPPLY DIFFUSER TO 400 CFM.11 EXISTING GE TYPE NLTQ EMERGENCY PANEL: PROVIDE A 20A/1-POLE CIRCUITBREAKER AT POSITION #9 FOR ACCESS CONTROL PANEL AND A 20A/1-POLE CIRCUITBREAKER AT POSITION #11 FOR FIRST FLOOR ADA DOOR OPERATORS. CIRCUITBREAKERS SHALL BE UL LISTED COMPATIBLE. MATCH AIC RATING OF EXISTINGBREAKERS. MODIFY PANELBOARD SCHEDULE ACCORDINGLY.12 PROVIDE A FIRE ALARM ADDRESSABLE MODULE ABOVE THE FINISHED CEILING FORTHE ADA OPERATOR FIRE ALARM SHUNT. CIRCUIT WITH 2#14 FPLP TO NEAREST SLCIN CORRIDOR 100CA. COORDINATE INSTALLATION WITH THE ADA OPERATORMANUFACTURER. DOOR SHALL RELEASE UPON FIRE ALARM ACTIVATION.13 ALL DUCTWORK AND ACCESSORIES SHALL BE FABRICATED AND INSTALLED INCOMPLIANCE WITH THE LATEST ISSUE OF SMACNA'S HVAC DUCT CONSTRUCTIONSTANDARDS-METAL AND FLEXIBLE. DUCT SHALL BE CONSTRUCTED OF G90GALVANIZED STEEL WITH A SEAL CLASS A, AND LEAKAGE CLASS 6.14 AT EXISTING CHASE WITH ACCESS DOOR: COREDRILL CONCRETE FLOOR ANDPROVIDE 1" RGS FLOOR SLEEVE FROM BASEMENT DATA CLOSET B03A FOR ACCESSCONTROL WIRING TO DOOR. PROVIDE UL LISTED FIRESTOP ASSEMBLY AT FLOORPENETRATION. CONCEAL ACCESS CONTROL WIRING IN WALLS, CHASES, AND ABOVEFINISHED CEILINGS.15 PROVIDE ALL NECESSARY ACCESS CONTROL TERMINATIONS AT DOOR FOR POWERTO ELECTRIC HINGES, AND DOOR CONTACTS.16 REMOVE EXISTING SIDEWALK PANEL BETWEEN JOINTS AS SHOWN. PROVIDEOVERSIZED PENETRATION THROUGH EXISTING CONCRETE WALL FOR CONDUIT.PROVIDE FLUID APPLIED SYSTEM SUCH AS GRACE PROCOR 20 AROUNDPENETRATION AND TIE INTO EXISTING WATERPROOFING SYSTEM. FOLLOWMANUFACTURER’S INSTALLATION INSTRUCTIONS FOR PIPE PENETRATIONS. SUBMITPROPOSED PRODUCT AND PROCEDURE FOR REVIEW AND APPROVAL. PROVIDE NEWDRAINAGE BOARD AS NEEDED.17 BACKFILL EXCAVATION WITH NYSDOT TYPE 4 GRAVEL. PLACE FOUR INCH CONCRETESLAB WITH 6X6-W2.9XW2.9 AT MID DEPTH OF CONCRETE. CONCRETE SHALL HAVE A4500 PSI COMPRESSIVE STRENGTH, 6% AIR ENTRAINED, W/C RATIO = 0.45 WITHLIMESTONE COARSE AND FINE AGGREGATE. PROVIDE FINISH AND SCORINGPATTERN TO MATCH ADJACENT EXISTING CONCRETE SIDEWALK PANELS. PROVIDESEVEN DAY WET CURE WITH BURLAP. INSTALL POLYURETHANE JOINT SEALANT TOREPLACE EXISTING SEALANT JOINTS REMOVED DURING SLAB PANEL DEMOLITION.PROVIDE CONCRETE MIX DESIGN AND SEALANT SUBMITTAL FOR REVIEW ANDAPPROVAL.SCALE: 3/16"=1'-0"0246 12N SSSSFFL1WL1E12453EXISTING RECEPTACLE ANDTV OUTLET TO REMAIN6EXISTING CABINET UNITHEATER TO REMAIN100CA104106100CA100CC278EXISTING EMERGENCYLIGHT TO REMAINCORNELLUNIVERSITYFOUNDED5681ADCornell UniversityFacilities EngineeringIT IS A VIOLATION OF NEW YORK STATE LAW FORANY PERSON, UNLESS ACTING UNDER THEDIRECTION OF A LICENSED ARCHITECT ORENGINEER, TO ALTER THIS DOCUMENT IN ANYWAY. IF THIS DOCUMENT IS ALTERED, THEALTERING ARCHITECT OR ENGINEER SHALL AFFIXTO SUCH DOCUMENT HIS SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISSIGNATURE, THE DATE OF SUCH ALTERATION,AND A SPECIFIC DESCRIPTION OF THEALTERATION.WARNING:Ithaca, New YorkDATE:FACILITY:DESIGN:DRAWN:ARCHIVE BAR CODEARCH/STRUCT:CIVIL/ENV:ELECTRICAL:MECHANICAL:Space Sciences BuildingMED-101PARTIAL FIRSTFLOORMECHANICALELECTRICAL DEMOPLANSpace Sciences Building Accessible EntryC. WAYMANcmw2084April 18, 20168740618SCALE: 1/4" = 1'-0"1PARTIAL FIRST FLOOR DEMOLITION PLANGENERAL DEMOLITION NOTES1.0 ELECTRICAL EQUIPMENT SHOWN DASHED ON DEMOLITION DRAWINGS, INCLUDINGASSOCIATED ANCHORS, SUPPORTS, STRAPS, BOXES, FITTINGS, AND OTHERAPPURTENANCES NOT SHOWN, SHALL BE DISCONNECTED AND REMOVED. REMOVEASSOCIATED BRANCH CIRCUITRY TO SOURCE, UNLESS NOTED OTHERWISE.2.0 EXISTING RACEWAYS AND DEVICE BACKBOXES NOT INTERFERRING WITH NEW WORKSHALL BE REUSED WHERE POSSIBLE.3.0 PROVIDE JUNCTION BOXES, RACEWAYS, AND WIRING TO MODIFY/EXTEND EXISTINGSYSTEMS AND CIRCUITS FED DOWNSTREAM OF ELECTRICAL EQUIPMENT SHOWN TOBE DEMOLISHED.4.0 CUT DEMOLISHED CONDUITS INSTALLED THRU WALLS AND FLOORS FLUSH WITH THESURFACE AND PATCH PENETRATIONS (FIRESTOP IF LOCATED ON A FIRE RATEDSURFACE). PATCH AND PAINT SURFACES IN EXPOSED AREAS TO MATCHSURROUNDING MATERIALS, FINISHES, AND COLORS.5.0 PROVIDE BLANK COVERPLATES ON UNUSED BACKBOXES REMAINING FROMDEMOLITION NOT SPECIFIED TO BE INFILLED.6.0 EXISTING EQUIPMENT SHOWN TO REMAIN SHALL BE PROTECTED DURINGCONSTRUCTION.MED-101 KEYED DEMOLITION NOTES1 DISCONNECT AND REMOVE TRACK LIGHTING. REMOVE BRANCH CIRCUITRY TOEXISTING LIGHT SWITCHES.2 DISCONNECT AND REMOVE RECEPTACLES INSTALLED ON STOREFRONT. REMOVEBRANCH CIRCUITRY TO SOURCE.3 DISCONNECT AND REMOVE POWER TO DOOR OPERATOR. REMOVE BRANCHCIRCUITRY TO SOURCE.4 DISCONNECT AND REMOVE VESTIBULE LIGHT SWITCH. REMOVE BRANCH CIRCUITRYTO SOURCE. PROVIDE A BLANK COVERPLATE.5 DISCONNECT AND REMOVE FAN COIL MOTOR RATED SWITCH. EXISTING SAFETYSWITCH INSTALLED ABOVE FINISHED CEILING TO REMAIN. PROVIDE A BLANKCOVERPLATE.6 REPLACE VESTIBULE LIGHT SWITCHES. TAG BRANCH CIRCUITRY FOR REUSE.7 REMOVE 8'-0" LINEAR SUPPLY DIFFUSER, PLENUM AND ASSOCIATED DUCT ASNECESSARY FOR INSTALLATION OF NEW 24"X24" SUPPLY DIFFUSER.8 DISCONNECT AND REMOVE DATA DROP FOR VOIP PHONE. REMOVE DATA CABLINGTO SOURCE.#024 8SCALE: 1/4"=1'-0"NREVISIONS1 3/18/16 ISSUED FOR REVIEW2 4/18/16 ISSUED FOR 95% REVIEW3 4/27/16 ISSUED FOR CONSTRUCTION