HomeMy WebLinkAboutSpace Sciences Building Accessible EntryCORNELL UNIVERSITY SPACE SCIENCES
FACILITIES CONTRACTS ACCESSIBLE ENTRY
121 HUMPHREYS SERVICE BUILDING
ITHACA, NEW YORK 14853-3701
ADDENDUM NO. 1
May 18, 2016
This Addendum contains changes to the requirements of the Contract Documents and Specifications.
Such changes are to be incorporated into the Construction Documents and shall apply to the work with
the same meaning and force as if they had been included in the original document. Wherever this
Addendum modifies a portion of a paragraph of the specifications or a portion of any Drawing, the
remainder of the Paragraph or Drawing shall remain in force.
NOTE: Provisions of all Contract Documents apply.
INSTRUCTION TO BIDDERS
Item 1. Instruction to Bidders, INS-2, Paragraph 7.a.
DELETE in its entirety.
REPLACE with
The project should be started within fifteen (15) calendar days from written authorization to
proceed, but work at the site shall start no earlier than July 1, 2016 and shall be completed no
later than October 31, 2016.
BID FORM
Item 2. Bid Form, BF-3, Paragraph 3.a.
REMOVE in its entirety.
REPLACE with
The undersigned agrees, if awarded the Contract, to commence work within fifteen (15)
calendar days from written authorization to proceed, but work at the site shall start no earlier
than July 1, 2016 and shall be completed no later than October 31, 2016.
Item 3. Attached is the Pre-Bid Sign-in Sheet, for reference only.
Item 4. RFI Questions and Clarifications
See attached RFI Log (Item 1)
Attachments: Pre-bid Meeting Sign-in Sheet
RFI Log (Item 1)
****END OF ADDENDUM****
SPACE SCIENCES BUILDING ACCESSIBLE ENTRY Date: May 18, 2016
RFI Form
RFI/Page/
Response Dwg./Spec./Rep.Section/Design Team
Index Number Paragraph/Topic RFI Response
1 General
Need clarification on emergency egress path.Contractor is required to designate and maintain an
emergency egress path of travel during construction.
CB CB CBCB
CB
CB
CB
CBCB
SPACE
SCIENCES
2084
ROCKEFELLER
HALL 2014
BIG RED
BARN 2040
CLARK HALL
2082
BAILEY HALL
1024
MALOTT
HALL 2081A.D. WHITE
HOUSE 2006
DRAWING LIST
GENERAL
T-001 TITLE SHEET
ARCHITECTURAL
A-000 GENERAL NOTES, SYMBOLOGY, ABBREVIATIONS, & KEY/CODE PLAN
A-100 PARTIAL BASEMENT ARCHITECTURAL DEMOLITION AND RENOVATION PLANS
A-101 PARTIAL FIRST FLOOR ARCHITECTURAL DEMOLITION AND RENOVATION PLANS
A-301 PARTIAL FIRST FLOOR DEMOLITION AND RENOVATION REFLECTED CEILING PLANS
ELECTRICAL
E-100 PARTIAL BASEMENT ELECTRICAL PLAN
E-400 ACCESS CONTROL AND ADA OPERATOR SCHEMATICS
MECHANICAL/ELECTRICAL
ME-000 SCOPE OF WORK, GENERAL NOTES, SYMBOLOGY, AND ABBREVIATIONS
ME-101 FIRST FLOOR MECHANICAL ELECTRICAL PLAN
MED-101 PARTIAL FIRST FLOOR MECHANICAL ELECTRICAL DEMO PLAN
CORNELLUNIVER S IT Y
F O U NDED5681ADCornell UniversityFacilities EngineeringIT IS A VIOLATION OF NEW YORK STATE LAW FOR
ANY PERSON, UNLESS ACTING UNDER THE
DIRECTION OF A LICENSED ARCHITECT OR
ENGINEER, TO ALTER THIS DOCUMENT IN ANY
WAY. IF THIS DOCUMENT IS ALTERED, THE
ALTERING ARCHITECT OR ENGINEER SHALL
AFFIX TO SUCH DOCUMENT HIS SEAL AND THE
NOTATION "ALTERED BY" FOLLOWED BY HIS
SIGNATURE, THE DATE OF SUCH ALTERATION,
AND A SPECIFIC DESCRIPTION OF THE
ALTERATION.
WARNING:Ithaca, New YorkDATE:
FACILITY:
DESIGN:
DRAWN:
ARCH/STRUCT:
CIVIL/ENV:
ELECTRICAL:
MECHANICAL:
Cornell University
Ithaca, New York
PROJECT SCOPE
Humphreys Service Building; Ithaca, N.Y.
Architectural & Structural, Civil &
Environmental, Mechanical and Electrical
Engineering
Facilities Engineering
ARCHIVE BAR CODEFE DESIGN
8740618 Space Sciences BuildingT-001
TITLE SHEET
jgc
2084
April 27, 2016Space Sciences Building Accessible EntrySpace Sciences Building
Accessible Entry
LOCATION PLAN - SPACE SCIENCES BUILDING
SITE PLAN - SPACE SCIENCES BUILDING
N
AREA OF WORK
The purpose of this project is to make renovations to the existing vestibule space
in order to accommodate ADA accessibility into and out of the Space Sciences
Building. The work for the new vestibule includes removal of the existing exterior
and interior storefront systems and the existing concealed spline ceiling system.
The new vestibule spaces will be provided with new aluminum storefront system
that includes automatic door operators, card readers, a recessed walk-off entry
mat system and new 2’ x 2’ suspended acoustical tile ceiling system. The work
also includes removal of the basement interior receiving doors and removal of
panic hardware on the exterior door. The exterior door will receive new panic
hardware and automatic door operator. Modifications to the electrical, mechanical,
and fire protection systems will also be included.
REVISIONS
1 3/18/16 ISSUED FOR 50% REVIEW
2 4/18/16 ISSUED FOR 95% REVIEW
3 4/27/16 ISSUED FOR CONSTRUCTION
N
AREA OF WORK
AREA OF WORK IN
BASEMENT (BELOW)
UP
22
N
INTERIOR ELEVATION
NORTH ARROW
SECTION
KEYNOTE - NEW WORK
KEYNOTE - DEMOLITION
TAG - CASEWORK
TAG - FURNISHING
TAG - DOOR
ROOM NAMEROOM #
M-6
0
WALL TYPE AND
FIRE RATING
011
999 ROOM DATA
ITEM FOR DEMOLITION
BREAK LINE
DOOR - EXISTING TO REMAIN
WALL - EXISTING TO REMAIN
WALL - EXISTING TO BE REMOVED
TAG - EQUIPMENT
TAG - FINISH
ELEVATION MARKER
B.O. BOTTOM OF
BYND BEYOND
CLG CEILING
DTL DETAIL
GWB GYPSUM WALL BOARD
MTL METAL
O.C. ON CENTER
PTD PAINTED
RCP REFLECTED CEILING PLAN
SIM SIMILAR
T.O. TOP OF
TYP TYPICAL
U.N.O. UNLESS NOTED OTHERWISE
U/S UNDERSIDE
V.I.F. VERIFY IN FIELD
THK THICK
WALL - GWB / METAL STUD
WALL - CMU
HM HOLLOW METAL
BATT INSULATION
E3
99
XX
XXXXX
XX
O 4
C
7
F1
A-101
2
A-101
1
100CC
100CA
106104 108 110
100SB
111
109
100CB
107105
101
100TA
100J
100TB
102
100SA
100E
A-100
2
A-100
1
B00CA B00CB
B00UA
B00E
B00SA
B02
B00JA
B00T
B03A
B04 B06 B10
B07
B03
B05
B00UB
B00UC
B00SB
BUILDING CODE SUMMARY
1. OCCUPANCY CLASSIFICATION:GROUP "B" BUSINESS
2. CONSTRUCTION TYPE:1A
3. CLASSIFICATION OF WORK:ALTERATION - LEVEL 2
4. GSF AREA OF ALTERATION:315 GSF
5. BUILDING SPRINKLERS:YES
CODE PLAN KEY
ALTERATION - LEVEL 2ARCHITECTURAL PATTERNS
ABBREVIATIONS
SYMBOLS
CORNELLUNIVER S IT Y
F O U NDED5681ADCornell UniversityFacilities EngineeringIT IS A VIOLATION OF NEW YORK STATE LAW FOR
ANY PERSON, UNLESS ACTING UNDER THE
DIRECTION OF A LICENSED ARCHITECT OR
ENGINEER, TO ALTER THIS DOCUMENT IN ANY
WAY. IF THIS DOCUMENT IS ALTERED, THE
ALTERING ARCHITECT OR ENGINEER SHALL AFFIX
TO SUCH DOCUMENT HIS SEAL AND THE
NOTATION "ALTERED BY" FOLLOWED BY HIS
SIGNATURE, THE DATE OF SUCH ALTERATION,
AND A SPECIFIC DESCRIPTION OF THE
ALTERATION.
WARNING:Ithaca, New YorkDATE:
FACILITY:
DESIGN:
DRAWN:ARCHIVE BAR CODEARCH/STRUCT:
CIVIL/ENV:
ELECTRICAL:
MECHANICAL:Space Sciences BuildingA-000
GENERAL NOTES,
SYMBOLOGY,
ABBREVIATIONS, &
KEY/CODE PLANSpace Sciences Building Accessible EntryJ. COOLBAUGH
jgc
2084
April 27, 2016
8740618
GENERAL NOTES
1.0 DESIGN, CONSTRUCTION AND SAFETY SHALL CONFORM TO ALL LOCAL, STATE AND
OWNER SPECIFIC CODES, INCLUDING (BUT NOT LIMITED TO) THE "NEW YORK STATE
UNIFORM FIRE PROTECTION AND BUILDING CODE", LATEST REVISION, THE NFPA 101
LIFE SAFETY CODE, LATEST REVISION, ANSI A117.1 - LATEST REVISION, OSHA, AND
ANY OTHER CODES GOVERNED BY THE JURISDICTION IN WHICH THIS PROJECT IS
BEING CONSTRUCTED.
2.0 THIS CONTRACT REQUIRES COMPLETE, FINISHED WORKABLE PROJECT OF THE
AREAS INDICATED BY THE CONTRACT DOCUMENTS, AND SHALL INCLUDE ALL
MATERIALS AND LABOR NECESSARY TO COMPLETE, REGARDLESS OF WHETHER OR
NOT ALL WORK OR EACH ITEM IS
SPECIFICALLY INDICATED ON ANY OTHER PORTION OF THE DRAWINGS AND / OR
NOTES.
3.0 WHERE MATERIALS REFERENCED ON DRAWINGS, OR NECESSARY TO COMPLETE THE
WORK OF THIS CONTRACT ARE NOT SPECIFIED HEREIN, PROVIDE BEST QUALITY
MATERIALS. WHERE MATERIALS ARE INTENDED TO MATCH EXISTING, PROVIDE
CLOSEST POSSIBLE MATCH, SUBJECT TO OWNER'S APPROVAL. ALL ITEMS AND
WORK ON DRAWINGS ARE NEW, UNLESS INDICATED EXISTING. ALL WORK WHICH HAS
BEEN DAMAGED SHALL BE REPAIRED OR REPLACED AT NO COST TO THE OWNER.
WHERE ITEMS CAN NOT BE REPAIRED TO A "NEW CONDITION", OR WHERE THE
STRUCTURAL INTEGRITY HAS BEEN AFFECTED, ITEMS SHALL BE REPLACED AT NO
COST TO THE OWNER.
4.0 CONTRACTOR IS RESPONSIBLE TO VERIFY ALL SITE, FIELD AND BUILDING
CONDITIONS PRIOR TO SUBMITTING BIDS AND COMMENCING WORK. IF THERE ARE
ANY DISCREPANCIES BETWEEN DRAWINGS AND FIELD CONDITIONS, NOTIFY THE
PROJECT MANAGER, WHO WILL REQUEST CLARIFICATION FROM THE
ARCHITECT/ENGINEER AND PROVIDE CLARIFICATION IN WRITING.
5.0 WHERE EXISTING CONSTRUCTION OR ITEMS HAVE BEEN INFILLED, REMOVED AND /
OR DISTURBED FOR INSTALLATION OF NEW WORK, CAUSING THE EXPOSURE OF
UNFINISHED AND/OR DAMAGED SURFACES RESULTING SURFACES AND INFILLED
SURFACES SHALL BE RECONSTRUCTED WITH MATERIALS TO MATCH FINISHED
AREAS. ALL ABANDONED OPENINGS (i.e. DUCT/PIPE REMOVALS, ETC.) AT WALLS,
ROOF OR FLOOR TO BE INFILLED SOLID.
6.0 WORK IS REQUIRED IN VARIOUS PORTIONS OF THE FACILITY TO EXECUTE WORK OF
OTHER TRADES (i.e. ELECTRICAL, MECHANICAL). ALTHOUGH NOT NECESSARILY
SHOWN ON DRAWINGS, WORK IS REQUIRED IN THESE AREAS CONSISTING OF
REMOVAL / REPLACEMENTOF CEILINGS, WALLS, FINISHES, PAVEMENT AND OTHER
CONSTRUCTION AS NECESSARY TO PERFORM WORK AND RESTORE THESE SPACES
OR AREAS TO ORIGINAL CONDITION.
7.0 GENERAL CONTRACTOR IS TO COORDINATE WORK OF ALL TRADES. SCHEDULE
WORK PROGRESS THROUGHOUT THE ENTIRE PROJECT TO PREVENT CONFLICTS
AND INTERFERENCES. OBTAIN ALL NECESSARY INFORMATION SUCH AS SIZES,
LOCATIONS, TEMPLATES, LAYOUT, DIMENSIONS AND ALL OTHER INFORMATION
NECESSARY FOR A PROPER AND WELL COORDINATED INSTALLATION. PRIOR TO
INSTALLATION OF ITEMS, VERIFY AND CONFIRM WITH EACH CONTRACTOR EXACT
LOCATION OF ALL ITEMS
8.0 ALL PENETRATIONS (EXISTING OR NEW )THROUGH FLOORS AND FULL HEIGHT WALLS
- IN AREA OF WORK TO BE FIRE STOPPED. ALL GAPS AND JOINTS AT RATED FLOORS,
ROOFS AND WALLS TO BE FIRE & SMOKE STOPPED. GAPS AND JOINTS INCLUDE (BUT
ARE NOT LIMITED TO) TOP OF WALL TO FLOOR OR ROOF DECK, WALL TO BEAMS, AND
CONTROL OR EXPANSION JOINTS. FIRE STOPPING INCLUDES BOTH FORM OR
PACKING MATERIAL AND THE FILL, VOID OR CAVITY MATERIAL.
9.0 JOBSITE WILL BE CLEANED DAILY AND DEBRIS REMOVED TO CONTAINERS OR TO
VEHICLE WHICH WILL REMOVE DEBRIS FROM CAMPUS. CONTAINERS WILL BE
REMOVED AS SOON AS FULL OR WHEN THE PROJECT HAS PROGRESSED TO A POINT
THAT A CONTAINER IS NO LONGER REQUIRED.
10.0 CONTRACTOR IS RESPONSIBLE FOR PROTECTING ALL AREAS USED TO BRING
SUPPLIES AND EQUIPMENT INTO THE PROJECT AREA. ANYDAMAGE TO AREAS
OUTSIDE THE PROJECT AREA INCLUDING BUT NOT LIMITED TO THE LOBBY AND
CORRIDOR SHALL BE REPAIRED AT NO COST TO THE OWNER.
SCALE: 1/8" = 1'-0"2 FIRST FLOOR KEY/ CODE PLAN
SCALE: 1/8" = 1'-0"1 BASEMENT KEY/ CODE PLAN
N
0 4 8 16
SCALE: 1/8"=1'-0"
N
0 4 8 16
SCALE: 1/8"=1'-0"
REVISIONS
1 3/18/16 ISSUED FOR 50% REVIEW
2 4/18/16 ISSUED FOR 95% REVIEW
3 4/27/16 ISSUED FOR CONSTRUCTION
F
F
F
1
B00CA
B00UA
B00E
B00CB
B00SA
B02
B00JA
B00T
UP
2
1
B00CA
B00CB
B00T
B00UA
B02
B00SA
B00E
B00JA
UP
2
3
B00CA
4 52"1' - 3"6"3' - 5"4"2' - 5"10"V.I.F.8' - 11" +/-V.I.F.
12' - 0" +/-
2"2' - 8"
2"
6' - 0"
2"
2' - 8"
2"
IG-1
IG-1
IG-1
IG-1
IG-1
IG-1
IG-1
IG-1
IG-1 IG-1 IG-1
MULLION
D1/F1 2"1' - 3"6"3' - 5"4"2' - 5"10"V.I.F.8' - 11" +/-V.I.F.
12' - 0" +/-
2"2' - 8"
2"
6' - 0"
2"
2' - 8"
2"
MG-1
MG-1
MG-1
MG-1
MG-1
MG-1
MG-1
MG-1
MG-1 MG-1 MG-1
D2/F2
3 5/8" METAL STUDS
AT 16" O.C. ATTACHED
TO SLAB ABOVE w/
5/8" GWB EACH SIDE
STOREFRONT SYSTEM
FASTENER SIZE AND
SPACING BY STOREFRONT
MANUFACTURER, SUBMIT
CALCULATIONS FOR
REVIEW. SHIM AS
REQUIRED.
BACKER ROD AND
SEALANT AS REQUIRED
2X2 ACT
BOX HEADER
3 5/8" METAL STUD KICKER
AT 48" MAX. ATTACHED TO
SLAB ABOVE
STOREFRONT SYSTEM
SHIM AS REQUIRED
BACKER ROD AND
SEALANT AS REQUIRED
EXISTING BRICK AND BLOCK
WALL TO REMAIN
MATCH EXISTING SETBACK1' - 10 1/2" +/- V.I.F.EXISTING PRECAST
EXISTING BRICK
NEW STOREFRONT
SYSTEM
SHIM AS REQUIRED
SEALANT AND BACKER
ROD AS REQUIRED
STOREFRONT SYSTEM
FASTENER SIZE AND
SPACING BY STOREFRONT
MANUFACTURER, SUBMIT
CALCULATIONS FOR
REVIEW. SHIM AS REQUIRED.
BACKER ROD AND
SEALANT AS REQUIRED
2X2 ACT
EXISTING PRECAST
CONCRETE
BOX HEADER
3 5/8" METAL STUD FRAMING
AT 16" O.C. & KICKERS AT
48" MAX. ATTACHED TO
PRECAST AND SLAB ABOVE
CORNELLUNIVER S IT Y
F O U NDED5681ADCornell UniversityFacilities EngineeringIT IS A VIOLATION OF NEW YORK STATE LAW FOR
ANY PERSON, UNLESS ACTING UNDER THE
DIRECTION OF A LICENSED ARCHITECT OR
ENGINEER, TO ALTER THIS DOCUMENT IN ANY
WAY. IF THIS DOCUMENT IS ALTERED, THE
ALTERING ARCHITECT OR ENGINEER SHALL AFFIX
TO SUCH DOCUMENT HIS SEAL AND THE
NOTATION "ALTERED BY" FOLLOWED BY HIS
SIGNATURE, THE DATE OF SUCH ALTERATION,
AND A SPECIFIC DESCRIPTION OF THE
ALTERATION.
WARNING:Ithaca, New YorkDATE:
FACILITY:
DESIGN:
DRAWN:ARCHIVE BAR CODEARCH/STRUCT:
CIVIL/ENV:
ELECTRICAL:
MECHANICAL:Space Sciences BuildingA-100
PARTIAL BASEMENT
ARCHITECTURAL
DEMOLITION AND
RENOVATION PLANSSpace Sciences Building Accessible EntryJ. COOLBAUGH
jgc
2084
April 27, 2016
8740618SCALE: 1/4" = 1'-0"2 PARTIAL BASEMENT DEMOLITION PLAN
SCALE: 1/4" = 1'-0"1 PARTIAL BASEMENT RENOVATION PLAN
A-100 KEYED DEMOLITION NOTES
1 REMOVE EXISTING DOORS, RECESSED FLOOR CLOSER, AND TOP PIVOT ONLY.
EXISTING HOLLOW METAL FRAME TO REMAIN.
2 REMOVE EXISTING DOOR HARDWARE THIS DOOR ONLY.
A-100 KEYED RENOVATION NOTES
1 INFILL HOLLOW METAL FRAME WHERE TOP PIVOT WAS REMOVED. PROVIDE STEEL
PLATE, MATCH EXISTING FRAME GAGE. WELD, GRIND, AND FILL HOLES. SAND, PRIME
AND PAINT ENTIRE FRAME. COLOR TO MATCH EXISTING FRAME COLOR.
2 PROVIDE STAINLESS STEEL PLATE TO COVER FLOOR WHERE EXISTING RECESSED
FLOOR CLOSER WAS REMOVED. SIZE OF PLATE TO BE 3/16" THICK AND LARGE
ENOUGH TO COVER THE EXISTING CLOSER AREA. PROVIDE COUNTERSINKING
SCREWS TO FASTEN PLATE TO FLOOR. FILL EXISTING HOLE IN FLOOR WITH
NON-SHRINK GROUT, MATCH EXISTING FLOOR ELEVATION.
3 PROVIDE NEW ADA OPERATOR AND NEW DOOR HARDWARE. REFER TO HARDWARE
SCHEDULE FOR MORE INFORMATION.
4 PROVIDE NEW ADA OPERATOR CONTROL BOLLARD. REFER TO DETAIL 5/A-101 FOR
MORE INFORMATION.
5 PROVIDE NEW ADA OPERATOR WALL CONTROL. REFER TO ME-101 FOR MORE
INFORMATION.
N
0 2 4 8
SCALE: 1/4"=1'-0"
N
0 2 4 8
SCALE: 1/4"=1'-0"
ARCHITECTURAL GENERAL NOTES
1.0 ALL DIMENSIONS ARE TO BE FIELD VERIFIED PRIOR TO THE START OF
CONSTRUCTION.
2.0 THE CONTRACTOR IS RESPONSIBLE TO PROTECT ANY EXISTING FLOORING TO
REMAIN DURING DEMOLITION. PROVIDE CONTINUOUS COVERAGE AS APPROVED BY
OWNER.
#
#
DOOR SCHEDULE
DOOR
NUMBER
DOOR FRAME DETAILS
FIRE RATING
GLAZING
TYPE
HARDWARE
GROUP NO.KEYED NOTES
SIZE SIZE SIZE
TYPE MAT FIN TYPE MAT FIN HEAD JAMB THRESHOLD
DOOR WIDTH
WIDTH HEIGHT THICKNESSPANELS PANEL WIDTH
B00CA (2) 3' - 0" 6' - 0" 7' - 5 1/2" 1 3/4" EX EX EX EX EX EX - - - - - 1
100CC.1 (2) 3' - 0" 6' - 0" 7' - 0" 1 3/4" D1 AL MB F1 AL MB 8/A-100 7/A-100 - - IG-1 2
100CC.2 (2) 3' - 0" 6' - 0" 7' - 0" 1 3/4" D2 AL MB F2 AL MB 5/A-100 6/A-100 - - MG-1 3
SCALE: 1/4" = 1'-0"3 DOOR/ FRAME ELEVATIONS
SCALE: 1 1/2" = 1'-0"7 INTERIOR HEAD DETAIL
SCALE: 1 1/2" = 1'-0"5 INTERIOR JAMB DETAIL
SCALE: 1 1/2" = 1'-0"4 EXTERIOR JAMB DETAIL
SCALE: 1 1/2" = 1'-0"6 EXTERIOR HEAD DETAIL
REVISIONS
1 3/18/16 ISSUED FOR 50% REVIEW
2 4/18/16 ISSUED FOR 95% REVIEW
3 4/27/16 ISSUED FOR CONSTRUCTION
ATTACH STOREFRONT FRAMING TO
EXISTING STRUCTURE AS PER
MANUFACTURER’S REQUIREMENTS.
1
2 3
7' - 6"2' - 6"7' - 0"2' - 6"
100CC
106104
100CA
A-101
3
1 2
1 2 3
4
4
100CC
106104
100CA
100CC.1
100CC.2
2' - 6"7' - 0"2' - 6"7' - 6"6
5
6
A-100
3
A-100
A
4
A-101
1st Floor
0' - 0"
2nd Floor
12' - 3"
100CC.1
12V.I.F.8' - 11" +/-V.I.F.
12' - 0" +/-
EXISTING
CONCRETE SLAB
EXISTING
REMAINING
STONE FLOORING
NEW STAINLESS STEEL
WALK OFF MAT. REFER
TO SPECIFICATION
SECTION 12 48 13.
INSTALL AS PER
MANUFACTURER'S
REQUIREMENTS
PROVIDE CONCRETE
LEDGE FOR PERIMETER
FRAME. DOWEL INTO
EXISTING SLAB.3" +/-V.I.F.2 1/2" +/-5 1/2" +/-PROVIDE LIQUID APPLY
WATER PROOFING
WEDGE ANCHORS AS PER
MANUFACTURER'S
RECOMMENDATIONS
BOLLARD MOUNTING
BRACKET
CONDUIT, REFER TO
DRAWING ME-101 FOR
MORE INFORMATION
4' - 0" MIN.MIN.
1' - 0"
ADA BOLLARD - INSTALL
AS PER MANUFACTURER'S
REQUIREMENTS
ADA PUSH BUTTON/
CARD READER LOCATION
3' - 6" MIN.CONCRETE SIDEWALK,
REFER TO ME-101 FOR
REPLACEMENT INFORMATION
BACKFILL, MATCH
EXISTING GRADE
CONCRETE SONOTUBE OR
PRECAST UNIT WITH CAST
ANCHOR BOLTS. COORDINATE
WITH BOLLARD MANUFACTURER
FOR BASE PLATE.CORNELLUNIVER S IT Y
F O U NDED5681ADCornell UniversityFacilities EngineeringIT IS A VIOLATION OF NEW YORK STATE LAW FOR
ANY PERSON, UNLESS ACTING UNDER THE
DIRECTION OF A LICENSED ARCHITECT OR
ENGINEER, TO ALTER THIS DOCUMENT IN ANY
WAY. IF THIS DOCUMENT IS ALTERED, THE
ALTERING ARCHITECT OR ENGINEER SHALL AFFIX
TO SUCH DOCUMENT HIS SEAL AND THE
NOTATION "ALTERED BY" FOLLOWED BY HIS
SIGNATURE, THE DATE OF SUCH ALTERATION,
AND A SPECIFIC DESCRIPTION OF THE
ALTERATION.
WARNING:Ithaca, New YorkDATE:
FACILITY:
DESIGN:
DRAWN:ARCHIVE BAR CODEARCH/STRUCT:
CIVIL/ENV:
ELECTRICAL:
MECHANICAL:Space Sciences BuildingA-101
PARTIAL FIRST FLOOR
ARCHITECTURAL
DEMOLITION AND
RENOVATION PLANSSpace Sciences Building Accessible EntryJ. COOLBAUGH
jgc
2084
April 27, 2016
8740618
SCALE: 1/4" = 1'-0"2 PARTIAL FIRST FLOOR DEMOLITION PLAN
SCALE: 1/4" = 1'-0"1 PARTIAL FIRST FLOOR RENOVATION PLAN
A-101 KEYED RENOVATION NOTES
1 NEW ALUMINUM STOREFRONT SYSTEM.
2 NEW ALUMINUM DOOR. REFER TO DOOR SCHEDULE FOR MORE INFORMATION.
3 NEW RECESSED STAINLESS STEEL WALK OFF MAT. REFER TO SPECIFICATION
SECTION 12 48 13 FOR TYPE. REFER TO DETAIL 4/A-101 FOR MORE INFORMATION.
4 CLEAN BRICK FREE OF DEBRIS AFTER THE REMOVAL OF EXISTING STOREFRONT
FRAMING. MATCH EXISTING SURROUNDING BRICK WALL. PATCH ALL EXISTING HOLES
IN BRICK WITH GROUT WHERE EXISTING STOREFRONT FRAME WAS REMOVED.
COLOR TO MATCH EXISTING BRICK.
5 PROVIDE NEW ADA OPERATOR CONTROL BOLLARD. REFER TO DETAIL 5/A-101 FOR
MORE INFORMATION.
6 PROVIDE NEW ADA OPERATOR WALL CONTROL. REFER TO ME-101 FOR MORE
INFORMATION.
A-101 KEYED DEMOLITION NOTES
1 REMOVE EXISTING ALUMINUM SLIDING DOOR SYSTEM IN ITS ENTIRETY. REMOVE ALL
ANCHORS AND SEALANT FROM EXISTING WALLS. TURN DOOR/ FRAME OVER TO
OWNER.
2 REMOVE EXISTING STOREFRONT SYSTEM IN ITS ENTIRETY. REMOVE ALL ANCHORS
AND SEALANT FROM EXISTING WALLS. TURN DOOR/ FRAME OVER TO OWNER.
3 CUT AND REMOVE EXISTING STONE FLOOR DOWN TO EXISTING STRUCTURAL
CONCRETE SLAB.
SCALE: 1/4" = 1'-0"3 SOUTH EXTERIOR ELEVATION
0 2 4 8
SCALE: 1/4"=1'-0"
N
0 2 4 8
SCALE: 1/4"=1'-0"
N
ARCHITECTURAL GENERAL NOTES
1.0 ALL DIMENSIONS ARE TO BE FIELD VERIFIED PRIOR TO THE START OF
CONSTRUCTION.
2.0 THE CONTRACTOR IS RESPONSIBLE TO PROTECT ANY EXISTING FLOORING TO
REMAIN DURING DEMOLITION. PROVIDE CONTINUOUS COVERAGE AS APPROVED BY
OWNER.
#
#
REVISIONS
1 3/18/16 ISSUED FOR 50% REVIEW
2 4/18/16 ISSUED FOR 95% REVIEW
3 4/27/16 ISSUED FOR CONSTRUCTION
SCALE: 3" = 1'-0"4 WALK OFF MAT DETAIL
SCALE: 3/4" = 1'-0"5 ADA BOLLARD DETAIL
F1
A1
2
8' - 11"
8' - 11"
1
3
A-301
CUH
NEW LIGHT FIXTURES
(TYP. OF 6) - REFER TO
DRAWING ME-101 FOR
MORE INFORMATION.
NEW SUPPLY DIFFUSER
- REFER TO DRAWING
ME-101 FOR MORE
INFORMATION.
NEW EXIT SIGN - REFER
TO DRAWING ME-101
FOR MORE INFORMATION.
NEW FIRE ALARM DEVICE
- REFER TO DRAWING
ME-101 FOR MORE
INFORMATION.
104 106
100CA
100CA
100CC
COORDINATE CEILING
WITH EXISTING
SPRINKLER HEAD TO
REMAIN.
EXISTING SOFFIT TO REMAIN.
PATCH AS REQUIRED. PAINT,
COLOR TO MATCH EXISTING.
NEW 2' x 2' ACOUSTICAL CEILING
SYSTEM (8' - 11" +/- A.F.F.)
EXISTING CEILING TO REMAIN
EXISTING WALL (BEYOND)CORNELLUNIVER S IT Y
F O U NDED5681ADCornell UniversityFacilities EngineeringIT IS A VIOLATION OF NEW YORK STATE LAW FOR
ANY PERSON, UNLESS ACTING UNDER THE
DIRECTION OF A LICENSED ARCHITECT OR
ENGINEER, TO ALTER THIS DOCUMENT IN ANY
WAY. IF THIS DOCUMENT IS ALTERED, THE
ALTERING ARCHITECT OR ENGINEER SHALL AFFIX
TO SUCH DOCUMENT HIS SEAL AND THE
NOTATION "ALTERED BY" FOLLOWED BY HIS
SIGNATURE, THE DATE OF SUCH ALTERATION,
AND A SPECIFIC DESCRIPTION OF THE
ALTERATION.
WARNING:Ithaca, New YorkDATE:
FACILITY:
DESIGN:
DRAWN:ARCHIVE BAR CODEARCH/STRUCT:
CIVIL/ENV:
ELECTRICAL:
MECHANICAL:Space Sciences BuildingA-301
PARTIAL FIRST FLOOR
DEMOLITION AND
RENOVATION
REFLECTED CEILING
PLANSSpace Sciences Building Accessible EntryJ. COOLBAUGH
jgc
2084
April 27, 2016
8740618SCALE: 1/4" = 1'-0"2 PARTIAL FIRST FLOOR RCP DEMOLITION PLAN
SCALE: 1/4" = 1'-0"1 PARTIAL FIRST FLOOR RCP RENOVATION PLAN
A-301 KEYED DEMOLITION NOTES
1 REMOVE EXISTING 1'X1' SPLINE CEILING SYSTEM IN ITS ENTIRETY. COORDINATE WITH
ELECTRICAL AND MECHANICAL DRAWINGS FOR LIGHT AND GRILL REMOVALS.
A-301 KEYED RENOVATION NOTES
1 NEW 2'X2' ACOUSTICAL CEILING SYSTEM
2 PATCH EXISTING SOFFIT WHERE EXISTING SPLINE CEILING SYSTEM WAS REMOVED.
MATCH EXISTING SOFFIT FINISH AND COLOR.
N
0 2 4 8
SCALE: 1/4"=1'-0"
N
0 2 4 8
SCALE: 1/4"=1'-0"
#
#
SCALE: 1 1/2" = 1'-0"3 SOFFIT DETAIL
REVISIONS
1 3/18/16 ISSUED FOR 50% REVIEW
2 4/18/16 ISSUED FOR 95% REVIEW
3 4/27/16 ISSUED FOR CONSTRUCTION
FFFEMAMRBARBCLBEB123416EXISTING EMTELEPHONEEXISTINGCONCRETE PADEXISTINGCHASE5EXISTING GENERATOREXHAUST DUCT67FASTEN PVC TO INSIDEFACE OF CONCRETE WALLEXISTINGPAVEMENT89EXISTING STEELBOLLARDSEXISTING ASPHALT1415REFER TO DETAIL #1/ME-101FOR CONTINUATION10ACCESSCONTROLPANELEXISTING DATAROOM ACCESSCONTROL PANEL12B02 B04B06B00SAB00EB00UAB03B03AB00TB00JAB00CBB00CA11EXISTING 2-POSTDATA RACKPROVIDE METAL SURFACE RACEWAY TOABOVE FINISHED CEILING AND 3/4" EMTTO ADA OPERATOR FOR ADA CONTROLSTATION WIRING3/4" EMT ABOVE FINISHED CEILINGFOR ADA OPERATOR POWER13DB1718EXISTING SIMPLEXCONVENTIONAL FIREALARM CONTROL PANELCORNELLUNIVERSITYFOUNDED5681ADCornell UniversityFacilities EngineeringIT IS A VIOLATION OF NEW YORK STATE LAW FORANY PERSON, UNLESS ACTING UNDER THEDIRECTION OF A LICENSED ARCHITECT ORENGINEER, TO ALTER THIS DOCUMENT IN ANYWAY. IF THIS DOCUMENT IS ALTERED, THEALTERING ARCHITECT OR ENGINEER SHALL AFFIXTO SUCH DOCUMENT HIS SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISSIGNATURE, THE DATE OF SUCH ALTERATION,AND A SPECIFIC DESCRIPTION OF THEALTERATION.WARNING:Ithaca, New YorkDATE:FACILITY:DESIGN:DRAWN:ARCHIVE BAR CODEARCH/STRUCT:CIVIL/ENV:ELECTRICAL:MECHANICAL:Space Sciences BuildingE-100PARTIALBASEMENTELECTRICAL PLANSpace Sciences Building Accessible EntryC. WAYMANcmw2084April 18, 20168740618SCALE: 1/4" = 1'-0"1PARTIAL BASEMENT POWER PLAN024 8SCALE: 1/4"=1'-0"NME-100 KEYED CONSTRUCTION NOTES1 PROVIDE FIRE ALARM MANUAL PULL STATION WITH SURFACE MOUNT BOX ANDSURFACE RACEWAY TO ABOVE FINISHED CEILING. INSTALL HANDLE AT 48" AFF.CIRCUIT WITH 2#14 FPLP ABOVE FINISHED CEILING TO EXISTING SLC IN CORRIDORB00CB.2 PROVIDE EMERGENCY LIGHTING BATTERY UNIT AND CIRCUIT TO THE UNSWITCHEDPHASE OF CORRIDOR B00CB LIGHTING BRANCH CIRCUIT FOR POWER SENSING ANDCHARGING. INSTALL TOP OF UNIT FLUSH WITH FINISHED CEILING.3 PROVIDE REMOTE, DUAL HEAD EMERGENCY LIGHT AND CIRCUIT TO THE EMERGENCYLIGHTING BATTERY UNIT WITH 2#12+GND MC CABLE. INSTALL CENTER OF UNIT AT7'-6" AFG. CONCREAL BRANCH CIRCUITRY WITHIN CHASE. PATCH EXTERIOR WALLPENETRATION.4 PROVIDE 2#12, 1#12G, 3/4" EMT FROM ADA OPERATOR TO PANEL EB IN CORRIDORB00CB. CONCEAL BRANCH CIRCUITRY ABOVE FINISHED CEILING.5 INSTALL ADA OPERATOR CONTROL STATION AT PEDESTAL. PROVIDE AN ACCESSCONTROL CARD READER AND INSTALL ON PEDESTAL.6 SAWCUT AND REMOVE ASPHALT AT LEAST 1'-0" BEYOND EACH SIDE OF TRENCH,EXCAVATE 18" BELOW GRADE, AND PROVIDE 1" PVC FROM PEDESTAL TO 6"x6" J-BOX(KEYED NOTE #9). STUB CONDUIT UP WITHIN PEDESTAL. BACKFILL EXCAVATIONWITH NYSDOT TYPE 4 GRAVEL AS NEEDED. PROVIDE NYSDOT TYPE 7 TOP HOT MIXASPHALT TO MATCH EXISTING ASPHALT THICKNESS. COMPACT ASPHALT WITHVIBRATORY TAMP TO MATCH EXISTING ASPHALT ELEVATION.7 COREDRILL 12" THICK, REINFORCED CONCRETE CURB AS SHOWN. TRANSITION TO 1"RGS AT CURB AND EXPOSED TO 6"x6" J-BOX (KEYED NOTE #9). MORTAR CURBPENETRATIONS AFTER RGS INSTALLATION.8 COREDRILL EXTERIOR WALL (BRICK ON EXTERIOR AND CMU ON INTERIOR) ANDPROVIDE 1" RGS BETWEEN OUTDOOR AND INTERIOR J-BOXES. SEAL WALLPENETRATIONS.9 PROVIDE A NEMA 3R 6"x6" PVC J-BOX ON EXTERIOR AND A NEMA 1 6"x6" GALVANIZEDJ-BOX ON INTERIOR.10 PROVIDE ACCESS CONTROL PANEL.11 PROVIDE A 4"x4" J-BOX NEXT TO ACCESS CONTROL PANEL WITH 3/4" BUSHED EMT TOCEILING. PROVIDE A CAT6 CABLE FROM PATCH PANEL IN THIS ROOM. PROVIDECOVERPLATE, TERMINATIONS, AND CABLE TESTING.12 PROVIDE 3/4" EMT ABOVE FINISHED CEILINGS FOR ACCESS CONTROL WIRING.13 PROVIDE 1-HOUR RATED FIRESTOP PENETRATIONS INTO CORRIDOR.14 PROVIDE A 6"x6" NEMA 1 GALVANIZED J-BOX FOR ACCESS CONTROL WIRING TOFIRST FLOOR ADA OPERATOR.15 COREDRILL CONCRETE FOUNDATION WALL AND TRANSITION TO 3/4" RGS THRUWALL. PROVIDE A LINK-SEAL AT WALL PENETRATION.16 EXISTING GE TYPE NLTQ EMERGENCY PANEL: PROVIDE A 20A/1-POLE CIRCUITBREAKER AT POSITION #15 FOR ACCESS CONTROL PANEL AND A 20A/1-POLE CIRCUITBREAKER AT POSITION #17 FOR BASEMENT ADA DOOR OPERATOR. CIRCUITBREAKERS SHALL BE UL LISTED COMPATIBLE. MATCH AIC RATING OF EXISTINGBREAKERS. MODIFY PANELBOARD SCHEDULE ACCORDINGLY.17 PROVIDE A FIRE ALARM ADDRESSABLE MODULE ABOVE THE FINISHED CEILING FORTHE ADA OPERATOR FIRE ALARM SHUNT. CIRCUIT WITH 2#14 FPLP TO NEAREST SLCIN CORRIDOR B00CB. COORDINATE INSTALLATION WITH THE ADA OPERATORMANUFACTURER. DOOR SHALL RELEASE UPON FIRE ALARM ACTIVATION.18 PROVIDE ALL NECESSARY ACCESS CONTROL TERMINATIONS AT DOOR FOR POWERTO ELECTRIC HINGES, REQUEST-TO-EXIT SENSOR, AND DOOR CONTACTS.#REVISIONS1 3/18/16 ISSUED FOR REVIEW2 4/18/16 ISSUED FOR 95% REVIEW3 4/27/16 ISSUED FOR CONSTRUCTION
ACCESSCONTROLPANELBASEMENTFIRST FLOORCARDREADERB03A6#22 STANLEY 2S22062GN54#18 STANLEY 2U18042BK52#18 STANLEY 2S18022RD5120V POWERCAT6 DATANOTE:PROVIDE A COMPLETE ACCESS CONTROL SYSTEM, INCLUDING HEADEND,CARD READERS, CONDUIT AND WIRE, AND PROGRAMMING. REFER TO ANDCOMPLY WITH CORNELL DESIGN STANDARD 281316.DOORHARDWAREDOORCONTACTSJBCARDREADER6#22 STANLEY 2S22062GN54#18 STANLEY 2U18042BK52#18 STANLEY 2S18022RD5DOORHARDWAREDOORCONTACTSJBADA DOORAUTO OPERATORCONTROLPANEL2#18 (TYP BETWEENCONTROL BUTTONSAND OPERATOR CONTROLPANEL)1617131422232#14 FPLP TO FIREALARM ADDRESSABLEMODULE (FIRE ALARMSHUNT)INTERIORADA CONTROLBUTTONEXTERIORADA CONTROLBUTTONMPAM RELAYCRASHBARLOCKSETCARD ACCESSSTRIKEADA OPERATORSTRIKE RELAY0V24VCARD ACCESS24V POWER120V POWERCORNELLUNIVERSITYFOUNDED5681ADCornell UniversityFacilities EngineeringIT IS A VIOLATION OF NEW YORK STATE LAW FORANY PERSON, UNLESS ACTING UNDER THEDIRECTION OF A LICENSED ARCHITECT ORENGINEER, TO ALTER THIS DOCUMENT IN ANYWAY. IF THIS DOCUMENT IS ALTERED, THEALTERING ARCHITECT OR ENGINEER SHALL AFFIXTO SUCH DOCUMENT HIS SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISSIGNATURE, THE DATE OF SUCH ALTERATION,AND A SPECIFIC DESCRIPTION OF THEALTERATION.WARNING:Ithaca, New YorkDATE:FACILITY:DESIGN:DRAWN:ARCHIVE BAR CODEARCH/STRUCT:CIVIL/ENV:ELECTRICAL:MECHANICAL:Space Sciences BuildingE-400ACCESS CONTROLAND ADAOPERATORSCHEMATICSSpace Sciences Building Accessible EntryC. WAYMANcmw2084April 18, 20168740618REVISIONS1 3/18/16 ISSUED FOR REVIEW2 4/18/16 ISSUED FOR 95% REVIEW3 4/27/16 ISSUED FOR CONSTRUCTIONSCALE: NO SCALE1ACCESS CONTROL SCHEMATIC DIAGRAMSCALE: NO SCALE2TYPICAL ADA MOTORIZED OPERATOR SCHEMATIC DIAGRAM
VALUESGTTETEGTTTG"NAME" (E)VALUETAG NO.TAG NO.TAG NO.?"X?"XXX"NAME"EXISTING PIPINGDEMOLITION WORKEXISTING EQUIPMENTPIPING TO BE REMOVEDPNEUMATIC THERMOSTATPNEUMATIC THERMOSTATPLEASE NOTE: IF EXISTING AN "E" IS ADDEDW/ GUARDTEMPERATURE SENSORELECTRIC THERMOSTATELECTRIC THERMOSTATW/ GUARDPNEUMATIC THERMOSTATW/ GUARDEQUIPMENT TAG (NON-MOTORIZED)EQUIPMENT TAG (MOTORIZED)DUCT UP (SUPPLY)CFM, GPM, CAPACITYNEW EQUIPMENTREGISTER, GRILLE, DIFFUSERCFM, GPM, CAPACITYNECK SIZEAFF ABOVE FINISHED FLOORPOINT OF CONNECTIONPOINT OF DISCONNECTIONTO BE REMOVEDTO BE REMAINCORNELLUNIVERSITYFOUNDED5681ADCornell UniversityFacilities EngineeringIT IS A VIOLATION OF NEW YORK STATE LAW FORANY PERSON, UNLESS ACTING UNDER THEDIRECTION OF A LICENSED ARCHITECT ORENGINEER, TO ALTER THIS DOCUMENT IN ANYWAY. IF THIS DOCUMENT IS ALTERED, THEALTERING ARCHITECT OR ENGINEER SHALL AFFIXTO SUCH DOCUMENT HIS SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISSIGNATURE, THE DATE OF SUCH ALTERATION,AND A SPECIFIC DESCRIPTION OF THEALTERATION.WARNING:Ithaca, New YorkDATE:FACILITY:DESIGN:DRAWN:ARCHIVE BAR CODEARCH/STRUCT:CIVIL/ENV:ELECTRICAL:MECHANICAL:Space Sciences BuildingME-000SCOPE OF WORK,GENERAL NOTES,SYMBOLOGY, ANDABBREVIATIONSSpace Sciences Building Accessible EntryC. WAYMANcmw2084April 18, 20168740618ELECTRICAL SYMBOLOGYMECHANICAL ABBREVIATIONS & SYMBOLOGYSCOPE OF WORKGENERAL NOTES1.0PROVIDE POWER TO ADA DOOR OPERATORS.2.0PROVIDE INTERIOR, EXTERIOR, AND EMERGENCY EGRESS LIGHTING.3.0PROVIDE AN ACCESS CONTROL SYSTEM: INCLUDING HEADEND,CARD READERS, DATA PORT, WIRING, PROGRAMMING, AND TESTING.3.0INTEGRATE ACCESS CONTROL SYSTEM WITH ADA DOOR OPERATORSTO PREVENT MOTORIZED DOORS FROM OPERATING WHEN THERE IS NOVALID CARD READ.4.0PROVIDE FIRE ALARM EQUIPMENT.5.0REMOVE AND REPLACE CONCRETE WALKWAY ON FIRST FLOOR FOR ADA PEDESTAL,AND TRENCH AND RESTORE PAVEMENT AT BASEMENT FOR ADA PEDESTAL.1.0ELECTRICAL SCHEMATICS INDICATED ON CONTRACT DOCUMENTS AREDIAGRAMMATIC. IT IS NOT THE INTENT TO SHOW EXACT OR MOSTEFFICIENT ROUTING. VERIFY ALL DIMENSIONS AND FIELD CONDITIONSON SITE. ANY CONFLICTS BETWEEN CONSTRUCTION DOCUMENTS ANDFIELD CONDITIONS SHALL BE BROUGHT TO CORNELL'S PROJECT MANAGERFOR RESOLUTION BEFORE WORK PROCEEDS.2.0ASSURE PUBLIC AND WORKER SAFETY AT ALL TIMES. PROTECT ADJOININGAREAS FROM DAMAGE AND DUST. REMOVE ALL DEBRIS FROM SITE ANDDISPOSE OF WASTE MATERIAL IN A SAFE MANNER. KEEP THE PREMISESFREE OF DEBRIS FROM THE EXECUTION OF WORK. DELIVER A FINALPRODUCT THAT IS CLEAN AND OPERABLE.3.0FIRE STOP ELECTRICAL PENETRATIONS THROUGH FIRE RATED WALLSAND/OR FLOORS WITH MATERIAL EQUAL IN RATING TO THE CONSTRUCTIONOF THE MATERIAL PENETRATED.4.0WORK SHALL BE COMPLETED AS SPECIFIED AND INDICATED ON CONTRACTDOCUMENTS. ANY SUGGESTED ALTERNATE MANUFACTURER OR METHODOF INSTALLATION SHALL BE SUBMITTED TO PROJECT ENGINEER FORAPPROVAL PRIOR TO ORDERING ANY MATERIALS OR COMMENCINGEXECUTION OF WORK.5.0GROUNDING SHALL BE IN STRICT ACCORDANCE WITH NEC ARTICLE 250.PROVIDE EQUIPMENT GROUND CONDUCTOR WITH EACH BRANCH CIRCUITINDICATED ON CONTRACT DOCUMENTS. EQUIPMENT GROUND CONDUCTORSHALL BE ROUTED WITH ASSOCIATED PHASE CONDUCTORS.6.0PROVIDE A NEW TYPED PANELBOARD DIRECTORY FOR EACH PANELBOARD.LABEL ALL NEW DEVICE FACEPLATES WITH SOURCE AND CIRCUIT NUMBER.PROVIDE PERMANENT LABEL ON SWITCHING DEVICES INDICATINGEQUIPMENT SERVICE AND INVENTORY NUMBERS. COORDINATE EQUIPMENTINVENTORY NUMBERS WITH CORNELL UNIVERSITY'S MECHANICAL SHOP,255-8667.7.0CIRCUITS RATED 20-AMP, 120 VOLT SHALL CONTAIN SEPARATE NEUTRALCONDUCTORS.8.0CONDUCTORS SHALL BE A MINIMUM OF 12AWG, STRANDED COPPER, 600VAC, 90DEGREE C, TYPE THHN/THWN FOR DRY AREAS AND XHHW/THWN-2 FOR WETAREAS.9.0CONDUITS SHALL BE A MINIMUM OF 3/4 INCHES DIAMETER. CONDUITSSHALL BE ELECTRICAL METALLIC TUBING (EMT) AND SURFACE MOUNTEDUNLESS NOTED OTHERWISE.10.0AIC RATING OF NEW CIRCUIT BREAKERS SHALL MATCH RATING OFRESPECTIVE PANELBOARD. SIZE AS INDICATED.11.0PROVIDE PULL STRING THROUGH NEW CONDUIT AND BOXES. PROVIDESUPPORT HANGERS FOR CONDUIT AS NEEDED.12.0INSTALL RACEWAY SYSTEMS ENSURING PROPER ACCESS TO EQUIPMENTAND DEVICES AND WITH SUFFICIENT SPACE TO PERFORM ROUTINEMAINTENANCE AND REPAIR. RACEWAYS THAT ARE NOT INSTALLED WITHTHIS REQUIREMENT IN MIND SHALL BE RELOCATED AT NO EXPENSE TOTHE UNIVERSITY UNTIL DEFICIENCIES ARE CORRECTED.99F10A103D16A103D16A103F10A103GENERAL SYMBOL LEGEND22XXXXXXXXXXXXXXXXXXXXXPOINT OF CONNECTION TO EXISTING WORK TO REMAINPOINT OF DEMOLITION TO EXISTING WORK TO REMAINCONDUIT DROP OR RISE AS INDICATEDCIRCUITAAAAAIR BREAK INTERRUPTER SWITCHFUSED DISCONNECT SWITCHTHERMAL MAGNETIC MOLDED CASE CIRCUIT BREAKERCTCURRENT TRANSFORMERPTPOTENTIAL TRANSFORMERMOV TYPE LIGHTNING ARRESTOR SIZE AND CLASSAS INDICATEDMETER/INSTRUMENT LETTER INDICATES FUNCTIONA - AMMETERPF - POWER FACTOR METERS - SYNCHROSCOPEVH - VARHOUR METERV - VOLT METERVAR- VARMETERW - WATTMETERWH - WATTHOUR METERWHD- WATTHOUR METER W/DEMAND REGISTERCIRCUIT MONITORMETER/INSTRUMENT SWITCH LETTERS INDICATEFUNCTION:AS - AMMETER SWITCHVS - VOLTMETER SWITCHWS - WATTMETER SWITCHASAND TYPETRANSFORMER, REFER TO SCHEDULE FOR SIZETGENERATOR SETGGROUND CONNECTIONTOP OF ROD 2'0" BELOW FINISHED GRADE UNLESSWELDS ONLY.MOLDED FUSION "T" EXOTHERMIC WELDS FOR GRIDCONNECTION , UNDERGROUND WORK.GROUND TERMINATION TO EQUIPMENT. (FRAME,GROUND BUS, TRANSFORMER NEUTRAL)6'-0" COIL FOR FUTURE USE.No. 4/0 STRANDED BARE COPPER PIGTAIL. MINIMUMDRAWOUT DEVICE1200AT1600AFCHARACTERISTICS INDICATED BY SUBSCRIPTS:CIRCUIT BREAKER SOLID STATE TRIPAT - TRIP COIL AMPERE RATINGAF - FRAME SIZE AMPERE RATINGCL - CURRENT LIMITINGL - LONG TIME TRIPS - SHORT TIME TRIPI - INSTANT ANEOUS TRIPG - GROUND FAULT TRIPSH - SHUNT TRIPSSTLSIGTRANSFER SWITCH, RATING ASINDICATED.ATS = AUTOMATIC10'-0" x 5/8" DIAMETER, COPPER CLAD GROUND ROD.CMSDFSTSPSSDBTSDBR135HDDDFFHDNFEMH190ELECTRICAL ONE-LINE SYMBOLS GENERAL ELECTRICAL SYMBOLSFIRE ALARM SYMBOLSSECURITY SYMBOLSLIGHTING SYMBOLSENLARGED DETAILEXTERIOR ELEVATIONINTERIOR ELEVATIONKEYNOTE DEMOLITIONKEYNOTE NEW WORKMATCH LINENORTH ARROWSECTIONEXISTING WORK TO REMAIN (GRAYSCALE)REMOVAL WORK (DASHED)NEW WORK (BOLD)THERMOSTATTSMOKE DETECTOR PHOTOELECTRONIC SENSORTRANSMITTER BEAM DETECTORRECEIVER BEAM DETECTORDUCT DETECTORTAMPER SWITCHLOW AIR SWITCHFLOW PRESSURE SWITCHHEAT DETECTOR 135 F OR 200 F FIXED TEMP SENSORFIRE ALARM PULL STATIONFIRE ALARM STROBE/HORN COMBOFIRE ALARM STROBE ONLYFIRE ALARM HORN ONLYP-1A12DRAWING REMOVAL KEYED NOTE INDICATORDRAWING CONSTRUCTION KEYED NOTE INDICATORPANELBOARD.LP-1JUNCTION BOX.SPECIAL PURPOSE RECEPTACLE DEVICE. PROVIDE SINGLEDEVICE WITH NEMA RATING AS INDICATED AND MATCHINGCOVER PLATE.MOTOR, NUMBER INSIDE SYMBOL INDICATES HORSEPOWER.5MANUAL MOTOR STARTER, SURFACE MOUNTED UNLESSOTHERWISE INDICATED.DISCONNECT SWITCH.COMBINATION STARTER.METERING DEVICE, TYPE INDICATED ON CONTRACT DOCUMENTS.THREE SPEED SWITCHTWO DUPLEX CONVENIENCE RECEPTACLES MOUNTED ON A SINGLEGANG PLATE.WWIRE MOLD SURFACE RACEWAYVARIABLE FREQUENCY DRIVE.X X X X X X XPLUGMOLDDUPLEX CONVENIENCE RECEPTACLE, GF = GROUND FAULTINTERRUPTER PROTECTION.BRANCH CIRCUITRY TO POWER RECEPTACLE DEVICE(S) IS NOTINDICATED ON THE CONTRACT DOCUMENTS. THE ALPHA-NUMERICTEXT ADJACENT TO THE DEVICE SYMBOL INDICATES THE PANELAND CIRCUIT NUMBER IT'S FED FROM. FOR EXAMPLE: P-1A/12INDICATES THAT THE DEVICE IS FED FROM PANEL P-1A, CIRCUIT #12.PROVIDE CIRCUITRY TO DEVICE(S) AS FOLLOWS: DEVICES INDICATEDWITH THE SAME CIRCUIT NUMBER SHALL BE CIRCUITED TOGETHERTO A 20AMP/1-POLE CIRCUIT BREAKER USING 2#12, 1#12G, IN 3/4 INCHEMT CONDUIT UNLESS INDICATED OTHERWISE. A MAXIMUM OF FOUR20 AMP, SINGLE PHASE BRANCH CIRCUITS CONSISTING OF(8#12, 1#12G) SHALL BE PERMITTED IN ONE INCH EMT CONDUIT.SINGLE POLE SWITCH.LIGHTING FIXTURE. FA = FIXTURE TYPE, REFER TOSPECIFICATIONS. a = CONTROL BY WALL SWITCH MARKEDSAME. EM = EMERGENCY POWER SOURCE.SINGLE POLE SWITCHES GANGED ON A SINGLE PLATE.MARKED SAME AS ABOVE.SECURITY SYSTEM PANIC BUTTONSSECURITY SYSTEM DOOR SWITCHTRACK LIGHTS.LIGHTS.SURFACE MOUNTED OR RECESSED DOWN LIGHTS.LIGHTING DIMMER.EXIT LIGHT.RAIMAGNETIC DOOR HOLDERRTSREMOTE TEST SWITCH/STATIONREMOTE ALARM INDICATORTHREE OR FOUR WAY SWITCH.OCCUPANCY SENSOR. "C" INDICATES CEILING MOUNTED."W" INDICATES WALL MOUNTED.OSCOMBINATION LIGHT SWITCH & OCCUPANCY SENSOR.AUXILIARY POWER SUPPLY.GENERATOR REMOTE ANNUNCIATOREMERGENCY WALLPACK LUMINAIREEMERGENCY/EXIT COMBO WALLPACK LUMINAIRECOMMUNICATION OUTLET. P/D INDICATES PHONE/DATA.WP INDICATES WALL PHONE OUTLET.DELECTRIC STRIKEHARDWIRED EQUIPMENT CONNECTIONP-1A12HOMERUN TO PANEL P-1A, CIRCUIT #12. FED FROM 20A - 1P BREAKERIS INTENDED UNLESS NOTED OTHERWISE. RUN GREEN WIRE GROUNDFOR ALL CIRCUITS. PROVIDE ONE GROUND PER CIRCUIT.SSS43FA EMaFB EMaSSOSSPBDSESFFAPSAP-1A12P-1A12JGFIM5-20RSVFDGRAS3-SPDEMERGENCY POWER OFF (EPO)GROUND ROD ELECTRODEEMELECTRICAL ABBREVIATIONSAFF ABOVE FINISHED FLOORAFG ABOVE FINISHED GRADEAFI ARC FAULT CIRCUIT INTERRUPTERAMM ADDRESSABLE MONITOR MODULEAOM ADDRESSABLE OUTPUT MODULEARB AUXILIARY RELAY BOARDATS AUTOMATIC TRANSFER SWITCHBKR BREAKERCCONDUITCD CANDELACKT CIRCUITCR CONTROL RELAYEC ELECTRICAL CONTRACTOREMT ELECTRICAL METALLIC TUBINGEPO EMERGENCY POWER OFF STATIONFAAP FIRE ALARM ANNUNCIATOR PANELFACP FIRE ALARM CONTROL PANELFSD FAN SHUT DOWNGAA GENERATOR ALARM ANNUNCIATORGFI GROUND FAULT CIRCUIT INTERRUPTERGND GROUNDHP HORSEPOWERKW KILOWATTLC LIGHTING CONTACTORLFMC LIQUID TIGHT FLEXIBLE METALLIC CONDUITLTG LIGHTINGMCB MAIN CIRCUIT BREAKERMLO MAIN LUG ONLYMTS MANUAL TRANSFER SWITCHNAC NOTIFICATION APPLIANCE PANELNIC NOT IN CONTRACTOE OVERHEAD ELECTRICPC PHOTOCELLPM PLUGMOLDPP POWER PANELPVC POLYVINYL CHLORIDERGS RIGID GALVANIZED STEELST SHUNT TRIPTM THERMAL MAGNETICTSP TWISTED SHIELDED PAIRTYP TYPICALUE UNDERGROUND ELECTRICUOI UNLESS OTHERWISE INDICATEDUPS UNINTERRUPTIBLE POWER SUPPLYVVOLTVA VOLT AMPSWP WATERPROOFREVISIONS1 3/18/16 ISSUED FOR REVIEW2 4/18/16 ISSUED FOR 95% REVIEW3 4/27/16 ISSUED FOR CONSTRUCTIONLUMINAIRE SCHEDULETYPE DESCRIPTION MOUNTING SIZE MANUFACTURER MODEL NO. VOLTAGE BALLAST LAMPS WATTAGE FINISHA LED DOWNLIGHT RECESSED 6" DIA. GOTHAM LIGHTING EVO-35/35-6WR-MWD-LD-MVOLT 120/277 LED LED 48.1 WHITEB EMERGENCY BATTERY LIGHT WALL 13"x7" LITHONIA ELM627-H1206 120/277 - 12W HALO 27 WHITEC EXIT SIGN UNIVERSAL 12"x7.5" SIMKAR SLEDBRW-SD 120/277 LED LED 3 WHITED EM REMOTE WALL 8.5"x5.75" LITHONIA ELA-B-T-QWP-L0309 12V - - 3 BLACKCSCONTROL STATIONELECTRICAL ABBREVIATIONS
SSFFFFAM1L1WL1E23844AAAAAA9104100CA106100CA100CCEXISTING CABINET UNITHEATER (DISCONNECTABOVE CEILING)1110105 107109100CB111100SB110108102100SA100TA100J101100E100TBE1CEXISTING EMERGENCYLIGHT (EXIT DISCHARGE)CS75REFER TO DETAIL #1/E-100FOR CONTINUATION6121314151530cd1617CORNELLUNIVERSITYFOUNDED5681ADCornell UniversityFacilities EngineeringIT IS A VIOLATION OF NEW YORK STATE LAW FORANY PERSON, UNLESS ACTING UNDER THEDIRECTION OF A LICENSED ARCHITECT ORENGINEER, TO ALTER THIS DOCUMENT IN ANYWAY. IF THIS DOCUMENT IS ALTERED, THEALTERING ARCHITECT OR ENGINEER SHALL AFFIXTO SUCH DOCUMENT HIS SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISSIGNATURE, THE DATE OF SUCH ALTERATION,AND A SPECIFIC DESCRIPTION OF THEALTERATION.WARNING:Ithaca, New YorkDATE:FACILITY:DESIGN:DRAWN:ARCHIVE BAR CODEARCH/STRUCT:CIVIL/ENV:ELECTRICAL:MECHANICAL:Space Sciences BuildingME-101FIRST FLOORMECHANICALELECTRICAL PLANSpace Sciences Building Accessible EntryC. WAYMANcmw2084April 18, 20168740618REVISIONS1 3/18/16 ISSUED FOR REVIEW2 4/18/16 ISSUED FOR 95% REVIEW3 4/27/16 ISSUED FOR CONSTRUCTIONSCALE: 3/16" = 1'-0"1FIRST FLOOR MECHANICAL ELECTRICAL PLAN#ME-101 KEYED CONSTRUCTION NOTES1 CIRCUIT EXIT SIGN TO EXISTING EXIT SIGN BRANCH CIRCUIT.2 PROVIDE FIRE ALARM MANUAL PULL STATION WITH SURFACE MOUNT BOX ANDSURFACE RACEWAY TO ABOVE FINISHED CEILING. INSTALL HANDLE AT 48" AFF.CIRCUIT WITH 2#14 FPLP ABOVE FINISHED CEILING TO EXISTING SLC IN CORRIDOR100CA.3 PROVIDE FIRE ALARM A/V NOTIFICATION APPLIANCE WITH SURFACE MOUNT BOX ANDSURFACE RACEWAY TO ABOVE FINISHED CEILING. INSTALL BOTTOM OF LENS AT 80"AFF. CIRCUIT WITH 2#14 FPLP ABOVE FINISHED CEILING TO EXISTING SLC INCORRIDOR 100CA.4 PROVIDE 2#12, 1#12G, 3/4" EMT FROM ADA OPERATOR TO PANEL E1 IN ROOM 109.CONCEAL BRANCH CIRCUITRY ABOVE FINISHED CEILING.5 INSTALL ADA OPERATOR CONTROL STATION AT PEDESTAL. PROVIDE AN ACCESSCONTROL CARD READER AND INSTALL ON PEDESTAL.6 TRENCH 18" BELOW GRADE AND PROVIDE 1" PVC FROM PEDESTAL TO 6"x6" J-BOX INBASEMENT ROOM B06. STUB CONDUIT UP WITHIN PEDESTAL.7 PROVIDE A 4"x4" SURFACE MOUNT J-BOX WITH SURFACE RACEWAY TO ABOVEFINISHED CEILING. INSTALL ADA OPERATOR AT 48" AFF TO CENTER OF OPERATOR.8 REPLACE LIGHT SWITCHES AND PROVIDE A 2-GANG COVERPLATE.9 PROVIDE RECESSED, LED DOWNLIGHTS AS SHOWN. MODIFY/EXTEND EXISTINGLIGHTING BRANCH CIRCUITRY.10 PROVIDE 24"X24" LAY-IN SUPPLY DIFFUSER (B.O.D. TITUS TDC, 14"X10" RECTANGULARNECK, STEEL) AND VOLUME DAMPER (B.O.D. 14"X10" GREENHECK MBD-15, OPPOSEDBLADE). EXTEND EXISTING 14"X10" SUPPLY DUCT AS NECESSARY TO COMPLETECONNECTION TO NEW SUPPLY DIFFUSER. VOLUME DAMPER SHALL BE INSTALLED ATLEAST 5'-0" FROM THE DIFFUSER. BALANCE SUPPLY DIFFUSER TO 400 CFM.11 EXISTING GE TYPE NLTQ EMERGENCY PANEL: PROVIDE A 20A/1-POLE CIRCUITBREAKER AT POSITION #9 FOR ACCESS CONTROL PANEL AND A 20A/1-POLE CIRCUITBREAKER AT POSITION #11 FOR FIRST FLOOR ADA DOOR OPERATORS. CIRCUITBREAKERS SHALL BE UL LISTED COMPATIBLE. MATCH AIC RATING OF EXISTINGBREAKERS. MODIFY PANELBOARD SCHEDULE ACCORDINGLY.12 PROVIDE A FIRE ALARM ADDRESSABLE MODULE ABOVE THE FINISHED CEILING FORTHE ADA OPERATOR FIRE ALARM SHUNT. CIRCUIT WITH 2#14 FPLP TO NEAREST SLCIN CORRIDOR 100CA. COORDINATE INSTALLATION WITH THE ADA OPERATORMANUFACTURER. DOOR SHALL RELEASE UPON FIRE ALARM ACTIVATION.13 ALL DUCTWORK AND ACCESSORIES SHALL BE FABRICATED AND INSTALLED INCOMPLIANCE WITH THE LATEST ISSUE OF SMACNA'S HVAC DUCT CONSTRUCTIONSTANDARDS-METAL AND FLEXIBLE. DUCT SHALL BE CONSTRUCTED OF G90GALVANIZED STEEL WITH A SEAL CLASS A, AND LEAKAGE CLASS 6.14 AT EXISTING CHASE WITH ACCESS DOOR: COREDRILL CONCRETE FLOOR ANDPROVIDE 1" RGS FLOOR SLEEVE FROM BASEMENT DATA CLOSET B03A FOR ACCESSCONTROL WIRING TO DOOR. PROVIDE UL LISTED FIRESTOP ASSEMBLY AT FLOORPENETRATION. CONCEAL ACCESS CONTROL WIRING IN WALLS, CHASES, AND ABOVEFINISHED CEILINGS.15 PROVIDE ALL NECESSARY ACCESS CONTROL TERMINATIONS AT DOOR FOR POWERTO ELECTRIC HINGES, AND DOOR CONTACTS.16 REMOVE EXISTING SIDEWALK PANEL BETWEEN JOINTS AS SHOWN. PROVIDEOVERSIZED PENETRATION THROUGH EXISTING CONCRETE WALL FOR CONDUIT.PROVIDE FLUID APPLIED SYSTEM SUCH AS GRACE PROCOR 20 AROUNDPENETRATION AND TIE INTO EXISTING WATERPROOFING SYSTEM. FOLLOWMANUFACTURER’S INSTALLATION INSTRUCTIONS FOR PIPE PENETRATIONS. SUBMITPROPOSED PRODUCT AND PROCEDURE FOR REVIEW AND APPROVAL. PROVIDE NEWDRAINAGE BOARD AS NEEDED.17 BACKFILL EXCAVATION WITH NYSDOT TYPE 4 GRAVEL. PLACE FOUR INCH CONCRETESLAB WITH 6X6-W2.9XW2.9 AT MID DEPTH OF CONCRETE. CONCRETE SHALL HAVE A4500 PSI COMPRESSIVE STRENGTH, 6% AIR ENTRAINED, W/C RATIO = 0.45 WITHLIMESTONE COARSE AND FINE AGGREGATE. PROVIDE FINISH AND SCORINGPATTERN TO MATCH ADJACENT EXISTING CONCRETE SIDEWALK PANELS. PROVIDESEVEN DAY WET CURE WITH BURLAP. INSTALL POLYURETHANE JOINT SEALANT TOREPLACE EXISTING SEALANT JOINTS REMOVED DURING SLAB PANEL DEMOLITION.PROVIDE CONCRETE MIX DESIGN AND SEALANT SUBMITTAL FOR REVIEW ANDAPPROVAL.SCALE: 3/16"=1'-0"0246 12N
SSSSFFL1WL1E12453EXISTING RECEPTACLE ANDTV OUTLET TO REMAIN6EXISTING CABINET UNITHEATER TO REMAIN100CA104106100CA100CC278EXISTING EMERGENCYLIGHT TO REMAINCORNELLUNIVERSITYFOUNDED5681ADCornell UniversityFacilities EngineeringIT IS A VIOLATION OF NEW YORK STATE LAW FORANY PERSON, UNLESS ACTING UNDER THEDIRECTION OF A LICENSED ARCHITECT ORENGINEER, TO ALTER THIS DOCUMENT IN ANYWAY. IF THIS DOCUMENT IS ALTERED, THEALTERING ARCHITECT OR ENGINEER SHALL AFFIXTO SUCH DOCUMENT HIS SEAL AND THENOTATION "ALTERED BY" FOLLOWED BY HISSIGNATURE, THE DATE OF SUCH ALTERATION,AND A SPECIFIC DESCRIPTION OF THEALTERATION.WARNING:Ithaca, New YorkDATE:FACILITY:DESIGN:DRAWN:ARCHIVE BAR CODEARCH/STRUCT:CIVIL/ENV:ELECTRICAL:MECHANICAL:Space Sciences BuildingMED-101PARTIAL FIRSTFLOORMECHANICALELECTRICAL DEMOPLANSpace Sciences Building Accessible EntryC. WAYMANcmw2084April 18, 20168740618SCALE: 1/4" = 1'-0"1PARTIAL FIRST FLOOR DEMOLITION PLANGENERAL DEMOLITION NOTES1.0 ELECTRICAL EQUIPMENT SHOWN DASHED ON DEMOLITION DRAWINGS, INCLUDINGASSOCIATED ANCHORS, SUPPORTS, STRAPS, BOXES, FITTINGS, AND OTHERAPPURTENANCES NOT SHOWN, SHALL BE DISCONNECTED AND REMOVED. REMOVEASSOCIATED BRANCH CIRCUITRY TO SOURCE, UNLESS NOTED OTHERWISE.2.0 EXISTING RACEWAYS AND DEVICE BACKBOXES NOT INTERFERRING WITH NEW WORKSHALL BE REUSED WHERE POSSIBLE.3.0 PROVIDE JUNCTION BOXES, RACEWAYS, AND WIRING TO MODIFY/EXTEND EXISTINGSYSTEMS AND CIRCUITS FED DOWNSTREAM OF ELECTRICAL EQUIPMENT SHOWN TOBE DEMOLISHED.4.0 CUT DEMOLISHED CONDUITS INSTALLED THRU WALLS AND FLOORS FLUSH WITH THESURFACE AND PATCH PENETRATIONS (FIRESTOP IF LOCATED ON A FIRE RATEDSURFACE). PATCH AND PAINT SURFACES IN EXPOSED AREAS TO MATCHSURROUNDING MATERIALS, FINISHES, AND COLORS.5.0 PROVIDE BLANK COVERPLATES ON UNUSED BACKBOXES REMAINING FROMDEMOLITION NOT SPECIFIED TO BE INFILLED.6.0 EXISTING EQUIPMENT SHOWN TO REMAIN SHALL BE PROTECTED DURINGCONSTRUCTION.MED-101 KEYED DEMOLITION NOTES1 DISCONNECT AND REMOVE TRACK LIGHTING. REMOVE BRANCH CIRCUITRY TOEXISTING LIGHT SWITCHES.2 DISCONNECT AND REMOVE RECEPTACLES INSTALLED ON STOREFRONT. REMOVEBRANCH CIRCUITRY TO SOURCE.3 DISCONNECT AND REMOVE POWER TO DOOR OPERATOR. REMOVE BRANCHCIRCUITRY TO SOURCE.4 DISCONNECT AND REMOVE VESTIBULE LIGHT SWITCH. REMOVE BRANCH CIRCUITRYTO SOURCE. PROVIDE A BLANK COVERPLATE.5 DISCONNECT AND REMOVE FAN COIL MOTOR RATED SWITCH. EXISTING SAFETYSWITCH INSTALLED ABOVE FINISHED CEILING TO REMAIN. PROVIDE A BLANKCOVERPLATE.6 REPLACE VESTIBULE LIGHT SWITCHES. TAG BRANCH CIRCUITRY FOR REUSE.7 REMOVE 8'-0" LINEAR SUPPLY DIFFUSER, PLENUM AND ASSOCIATED DUCT ASNECESSARY FOR INSTALLATION OF NEW 24"X24" SUPPLY DIFFUSER.8 DISCONNECT AND REMOVE DATA DROP FOR VOIP PHONE. REMOVE DATA CABLINGTO SOURCE.#024 8SCALE: 1/4"=1'-0"NREVISIONS1 3/18/16 ISSUED FOR REVIEW2 4/18/16 ISSUED FOR 95% REVIEW3 4/27/16 ISSUED FOR CONSTRUCTION