Detail Bill of Material Page 1 of 1
Project Name: STONE QUARRY Negotiation No: SY880507X4K1
General Order
No: Alternate No: 0003
Item No. Qty Product Description
2 Group Metering Aluminum Bus, NON-EUSERC, Total Number of Structures:
Catalog No 1MFS400RB
Designation TOWNHOME
Qty List of Materials
1 [1MFS400RB] MAIN SERVICE MODULE, 400A 1 PHASE MAIN FUSIBLE
SWI
1 [1MM512RRLB] 1 PHASE RINGLESS WITH HORN BYPASS M.M., 125A
8 [BR260] Type BR Breaker 60A/2 Pole 120/240V 10K
1 [1MM412RRLB] 1 PHASE RINGLESS WITH HORN BYPASS M.M., 125A
Item No. Qty Product Description
2 BR RESIDENTIAL
BREAKERS
Type BR Breaker 20/2 Pole 120/240V 10K
Catalog No BR220B
Designation TOWNHOUSES
Qty List of Materials
2 Type BR Breaker 20/2 Pole 120/240V 10K
Item No. Qty Product Description
1 Group Metering Aluminum Bus, NON-EUSERC, Total Number of Structures:
Catalog No 3MFS800RB
Designation APT
Qty List of Materials
1 [3MFS800RB] MAIN SERVICE MODULE, 800A 3 PHASE MAIN FUSIBLE
SWI
2 [3MM612RRLB] 3 PHASE RINGLESS WITH HORN BYPASS M.M., 125A
2 [BRHH2100] Type BR Breaker 100A/2 Pole Com. Trip 120/240V 42K
17 [BRHH260] Type BR Breaker 60A/2 Pole Com. Trip 120/240V 42K
1 [3MM412RRLB] 3 PHASE RINGLESS WITH HORN BYPASS M.M., 125A
1 [3MM312RRLB] 3 PHASE RINGLESS WITH HORN BYPASS M.M., 125A
1 [37MM140R1240300] 3 Phase, 7 Jaw Comm Meter Module, 1 socket, 300A
T
Eaton Selling Policy 25-000 applies.
All orders must be released for manufacture within 90 days of date of order entry. If approval drawings are required, drawings must be returned
approved for release within 60 days of mailing. If drawings are not returned accordingly, and/or if shipment is delayed for any reason, the price of the
order will increase by 1.0% per month or fraction there of for the time the shipment is delayed.
Group Metering General Information
Specifications
Utility Approval NON-EUSERC
Bus Type Aluminum
Breaker Information
8 BR260 Type BR Breaker 60A/2 Pole 120/240V 10K
Miscellaneous Specifications
Approval Drawings:No Autocad Drawings:No
Standard Instructions Books:No Certified Test Report (Std):No
Enclosure Properties
Struct #Width Depth Description/Modifications Catalog Number
1 20 11.75 Structure, 1MFS400RB
2 12.26 7.015 Structure, 1MM512RRLB
3 12.26 7.015 Structure, 1MM412RRLB
Total of 3 Structures, Total Width of 44.52 Inches
NEG-ALT Number
PREPARED BY DATE
APPROVED BY DATE
VERSION
REVISION DWG SIZE
JOB NAME
DESIGNATION
TYPE
G.O.
DRAWING TYPE
ITEM SHEET
The information on this document is
created by Eaton Corporation. It is
disclosed in confidence and it is only to
be used for the purpose in which it is
supplied.
SY880507X4K1-0003
SY88 12/17/2014
8.0.0.0
0 A
Eaton
STONE QUARRY
TOWNHOME
Group Metering Customer Appr.
1 of 2
1
Main
3
1
2
3
4
2
1
2
3
4
5
Structure 1 2 3
Wdth-Inches
Wdth-MM
20 12.26 12.26
508 311 311
Depth-Inches
Depth-MM
11.75 7.015 7.015
298 178 178
Height-Inches
Height-MM
47.625 57.5 48.5
1209 1460 1231
Tab Size-Inches
Tab Size-MM
2
50
NEG-ALT Number
PREPARED BY DATE
APPROVED BY DATE
VERSION
REVISION DWG SIZE
JOB NAME
DESIGNATION
TYPE
G.O.
DRAWING TYPE
ITEM SHEET
The information on this document is
created by Eaton Corporation. It is
disclosed in confidence and it is only to
be used for the purpose in which it is
supplied.
SY880507X4K1-0003
SY88 12/17/2014
8.0.0.0
0 A
Eaton
STONE QUARRY
TOWNHOME
Group Metering Customer Appr.
2 of 2
Group Metering General Information
Specifications
Utility Approval NON-EUSERC
Bus Type Aluminum
Breaker Information
2 BRHH2100 Type BR Breaker 100A/2 Pole Com. Trip 120/240V 42K
17 BRHH260 Type BR Breaker 60A/2 Pole Com. Trip 120/240V 42K
Miscellaneous Specifications
Approval Drawings:No Autocad Drawings:No
Standard Instructions Books:No Certified Test Report (Std):No
Enclosure Properties
Struct #Width Depth Description/Modifications Catalog Number
1 20 11.75 Structure, 3MFS800RB
2 12.26 7.015 Structure, 3MM612RRLB
3 12.26 7.015 Structure, 3MM612RRLB
4 12.26 7.015 Structure, 3MM412RRLB
5 12.26 7.015 Structure, 3MM312RRLB
6 18.25 9.56 Structure, 37MM140R1240300
Total of 6 Structures, Total Width of 87.29 Inches
Note: 400A KD-type breakers are factory installed in the 400A Commercial Stacks
NEG-ALT Number
PREPARED BY DATE
APPROVED BY DATE
VERSION
REVISION DWG SIZE
JOB NAME
DESIGNATION
TYPE
G.O.
DRAWING TYPE
ITEM SHEET
The information on this document is
created by Eaton Corporation. It is
disclosed in confidence and it is only to
be used for the purpose in which it is
supplied.
SY880507X4K1-0003
SY88 12/17/2014
8.0.0.0
0 A
Eaton
STONE QUARRY
APT
Group Metering Customer Appr.
1 of 2
1
Main
5
1
2
3
2
1
2
3
4
5
6
3
1
2
3
4
5
6
4
1
2
3
4
6
1
Structure 1 2 3 4 5 6
Wdth-Inches
Wdth-MM
20 12.26 12.26 12.26 12.26 18.25
508 311 311 311 311 463
Depth-Inches
Depth-MM
11.75 7.015 7.015 7.015 7.015 9.56
298 178 178 178 178 242
Height-Inches
Height-MM
47.625 66.5 66.5 48.5 41.8 52.65
1209 1689 1689 1231 1061 1337
Tab Size-Inches
Tab Size-MM
2
50
NEG-ALT Number
PREPARED BY DATE
APPROVED BY DATE
VERSION
REVISION DWG SIZE
JOB NAME
DESIGNATION
TYPE
G.O.
DRAWING TYPE
ITEM SHEET
The information on this document is
created by Eaton Corporation. It is
disclosed in confidence and it is only to
be used for the purpose in which it is
supplied.
SY880507X4K1-0003
SY88 12/17/2014
8.0.0.0
0 A
Eaton
STONE QUARRY
APT
Group Metering Customer Appr.
2 of 2
Volume 1—Residential and Light Commercial CA08100002E—September 2012 www.eaton.com V1-T5-129
5
5.11Metering Products
Group Metering
35MM, 37MM, 35SS and 37SS
Commercial Meter Stack Modules (35MM, 37MM, 35SS and 37SS)
Commercial Meter Stack Modules
Product Description
●Heavy-duty lever bypass
socket design
●Single-phase or three-
phase designs (35 = single-
phase, 37 = three-phase)
●Provision for two-pole or
three-pole main tenant
breakers
●Phase balance kits are
included with three-high
and four-high modules
Features, Benefits
and Functions
A. End Walls
The top cap is removable and
does not contain knockouts,
so contractors can position
and punch holes where they
need them. There are
numerous KOs in the back
and bottom for flexibility.
B. Ground Bars
The factory-installed
equipment ground bars are
provided in both the top and
bottom gutters.
C. Meter Socket
The 5-jaw meter socket and
7-jaw meter socket includes a
built-in manual bypass and jaw
release. The ground wire is
factory connected in both
35MM and 37MM modules.
D. Separate Wireway Cover
If work on the breakers or
cables is necessary, it can
be accomplished without
disturbing the meters or
meter covers, thanks to a
separate cover that allows
easy access to the module’s
main tenant breaker and
wireway section.
(Not shown.)
E. Barrier
A solid metal barrier
separates the meter socket
section from the tenant
breaker in the wireway
section. The unmetered
vertical bus is enclosed to
guard against power theft.
F. Neutral Assembly
Located in the wireway of
each module, the assembly
permits convenient
termination of the neutral
conductors.
G. Enclosed Horizontal Bus
Non-removable metal barrier
encloses 1200A horizontal
bus when passing through
the tenant breaker section
for added security.
H. Tenant Breaker Range
All modules accept 15–225A
bolt-on breakers in various
AIC ratings. The CHH_X
breaker carries a UL listed
series rating of 100,000A,
which allows you to use
standard 10 kAIC breakers in
downstream loadcenters and
panelboards by Eaton.
I. Indoor/Outdoor Construction
Raintight caps, meter covers
and lockable raintight tenant
breaker covers make it
convenient for you to use
any of our modules on either
NEMA 1 or NEMA 3R
applications.
J. Mounting Rail
Rear mounting rail and wall
hanger speed and simplify
installation. (Mounting rail
not shown.)
K. Nameplate and Ratings
The nameplate gives you full
rating data: 208Y/120, three-
phase, four-wire; 240/120,
three-phase, four-wire delta
(high leg on B-phase); and
240/120 single-phase.
(Not shown.)
L. Mains and Modules
Slip together quickly,
smoothly with front-
accessible captive bolts
securing the juncture without
removing socket interiors or
bus access plate. Main bus
joint bolts torque to 25 foot
pounds.
V1-T5-130 Volume 1—Residential and Light Commercial CA08100002E—September 2012 www.eaton.com
5
5.11 Metering Products
Group Metering
37MM Meter Stack Module ●Eaton’s 35MM and 37MM
modular metering stacks
contain meter sockets with
built-in manual bypass and
jaw release (Non-EUSERC
areas)
●Eaton’s 35SS and 37SS
stacks use meter sockets
with test bypass feature
(meets EUSERC electrical
requirements)
●All commercial modular
metering stacks contain
four horizontal cross buses
●Mechanically and
electrically built to bolt-up
with main service modules
and residential modular
metering stacks
Catalog Number Selection
Commercial Meter Stack Modules
When Ordering:
1. Determine catalog number of Main Service Module.
2. Determine catalog number of Meter Stack (Residential or Commercial).
3. Find quantity and catalog numbers for tenant circuit breakers (found on Page V1-T5-136). Order one breaker per socket.
4. If any accessories are needed, order from Pages V1-T5-138 and V1-T5-139.
L
B
G
F
E
H
C
I
A
Phases
Three-phase only
Number of Jaws
5 or 7
Socket Amperage
20 = 200A
40 = 400A
Number of Meters
1, 2, 3 or 4
Socket Type
K = K Base bolt-on socket
Blank = Plug-in type socket
Type of Metering
MM = Commercial metering module
SS = Safety socket—EUSERC
Bus
12 = 1200A main bus ampacity
AB = Phases A&B—EUSERC
AC = Phases A&C—EUSERC
BC = Phases B&C—EUSERC
Enclosure
R = NEMA 3R
Tenant Breakers
40 = 400A included
Blank = Ordered separately
Bus
C = Copper
Blank = Aluminum
3 7 MM 1 40 R 12 40 K C
V1-T5-132 Volume 1—Residential and Light Commercial CA08100002E—September 2012 www.eaton.com
5
5.11 Metering Products
Group Metering
37MM
●Each socket is a 7 terminal
block with lever bypass and
jaw release
●Ringless covers
●Provision for three-pole
main tenant breakers
(circuit breakers not
included). For circuit
breaker catalog numbers,
refer to Page V1-T5-136
●Indoor/outdoor
construction
●Main tenant breakers can
exit top, bottom or back
●If being used in outdoor
application and exiting the
top, mount Myer type hubs
on rainproof cap
●Short-circuit ratings up to
100A rms symmetrical
depending upon the kAIC
rating of installed main
tenant circuit breakers
and main device
●Non-EUSERC areas
37MM—Three-Phase Commercial Meter Stack Modules (Three-Phase In, Three-Phase Out)
Notes
1 If a socket in a 37MM meter stack module needs to be single-phase, order 37MM1CK. This will convert the three-phase socket to single-phase.
2 EHD main tenant breakers require one 37MMCBK kit per breaker.
3 320A continuous rated socket with provisions for two main tenant breakers.
4 Unit is bottom exit only.
5 Rated at 100 kAIC.
6 Rated at 25 kAIC.
7 Rated at 35 kAIC.
System
Voltage
Ampere Rating
Per Meter Socket
Number
of Meter
Sockets
Horizontal
Bus
Ampacity/
Material
Number of
Jaws Per
Meter Socket 1
Main Tenant
Breaker Type
(Page V1-T5-136)
Catalog
Number
208Y/120V, three-phase, four-wire
240/120V, three-phase, four-wire delta
(B-phase is high leg)
225 1 1200 Al 7 Bolt-on type 37MM120R12
1 1200 Cu 7 37MM120R12C
2 1200 Al 7 EHD3_
2 37MM220R12
2 1200 Cu 7 37MM220R12C
3 1200 Al 7 CC3_X 37MM320R12
3 1200 Cu 7 37MM320R12C
4 1200 Al 7 CHH3_H2X 37MM420R12
4 1200 Cu 7 37MM420R12C
400 1 1200 Al 7 CHH3_H4X
CHH3_
37MM140R12 3
1 1200 Cu 7 37MM140R12C 3
400 1 1200 Al 7 400A
K-Frame included
37MM140R1240 4
1200 Cu 7 37MM140R1240C 4
400 1 1200 Al 7 400A
K-Frame included
37MM140HR1240 5
1200 Cu 7 37MM140HR1240C 5
400 2 1200 Al 7 400A
K-Frame included
37MM240R1240
2 1200 Cu 7 37MM240R1240C
400 continuous 1 1200 Cu 7 400A
L-Frame included
37MM140R1240KC 6
400 continuous 1 1200 Cu 7 400A
L-Frame included
37MM140HR1240KC 7
V1-T5-134 Volume 1—Residential and Light Commercial CA08100002E—September 2012 www.eaton.com
5
5.11 Metering Products
Group Metering
Approximate Dimensions in Inches (mm)
Commercial Stacks (35MM and 37MM)
35MM and 37MM
19.25
(489.0)
66.63
(1692.3)25.38
(644.5)
14.00
(355.6)
Typ.
52.63
(1336.7)
52.63
(1336.7)
8.75
(222.3)
35MM140R1240
37MM140R1240
same as below
except eliminate
top socket.
18.25
(463.6)
8.75
(222.3)
18.25
(463.6)
8.75
(222.3)
18.25
(463.6)
8.75
(222.3)
V4-T2-154 Volume 4—Circuit Protection CA08100005E—June 2014 www.eaton.com
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2.3 Molded Case Circuit Breakers
Series C
Typical K-Frame Circuit Breaker Contents
Description Page
Product Overview. . . . . . . . . . . . . . . . . . . . . . . . . . .V4-T2-110
Standards and Certifications. . . . . . . . . . . . . . . . . . .V4-T2-111
Quick Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . .V4-T2-112
G-Frame (15–100 Amperes) . . . . . . . . . . . . . . . . . . .V4-T2-115
F-Frame (10–225 Amperes) . . . . . . . . . . . . . . . . . . .V4-T2-129
J-Frame (70–250 Amperes). . . . . . . . . . . . . . . . . . . .V4-T2-146
K-Frame (70–400 Amperes)
Catalog Number Selection. . . . . . . . . . . . . . . . . .V4-T2-155
Product Selection . . . . . . . . . . . . . . . . . . . . . . . .V4-T2-157
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . .V4-T2-174
Technical Data and Specifications . . . . . . . . . . . .V4-T2-175
Dimensions and Weights . . . . . . . . . . . . . . . . . .V4-T2-178
L-Frame (125–600 Amperes) . . . . . . . . . . . . . . . . . .V4-T2-179
M-Frame (300–800 Amperes). . . . . . . . . . . . . . . . . .V4-T2-205
N-Frame (400–1200 Amperes) . . . . . . . . . . . . . . . . .V4-T2-216
R-Frame (800–2500 Amperes) . . . . . . . . . . . . . . . . .V4-T2-231
Motor Circuit Protectors (MCP) . . . . . . . . . . . . . . . .V4-T2-250
Motor Protection Circuit Breakers (MPCB). . . . . . . .V4-T2-261
Type ELC Current Limiter Attachment (Size 0–4) . . . . .V4-T2-263
Current Limiting Circuit Breaker Module . . . . . . . . . . .V4-T2-264
Internal Accessories . . . . . . . . . . . . . . . . . . . . . . . . .V4-T2-268
External Accessories . . . . . . . . . . . . . . . . . . . . . . . .V4-T2-299
K-Frame (70–400 Amperes)
Product Description
●All Eaton K-Frame circuit
breakers are HACR rated
●K-Frame circuit breakers are
available as individual
components (frame, trip
unit, terminals), or factory
assembled complete
breakers
●K-Frame circuit breakers
with non-interchangeable
trip units are suitable for
reverse feed use
Volume 4—Circuit Protection CA08100005E—June 2014 www.eaton.com V4-T2-157
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2.3Molded Case Circuit Breakers
Series C
Product Selection
Types KD, HKD and KDC Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units
Notes
1 Magnetic trip adjustable 5–10 times continuous ampere rating.
2 Individually packed.
3 2TA400K, 3TA400K and 4TA400K terminal kits contain one terminal for each pole and one terminal cover.
Maximum
Continuous
Ampere Rating
at 40°C
Standard Interrupting
Capacity
600 Vac Rated
35 kAIC at 480 Vac
High Interrupting
Capacity
600 Vac Rated
65 kAIC at 480 Vac
Ultra High Interrupting
Capacity Current Limiting
600 Vac Rated
100 kAIC at 480 Vac
Thermal-Magnetic
Trip Unit Only 1
For Use with Standard
or High or Ultra High
Interrupting Frames
Standard Terminals Only
See Page V4-T2-173 for
Optional Terminals
Factory Assembled
Circuit Consisting
of Frame, Trip Unit
and Terminals 1
Factory Assembled
Circuit Consisting
of Frame, Trip Unit
and Terminals 1
Factory Assembled
Circuit Consisting
of Frame, Trip Unit
and Terminals 1
Catalog
Number
Catalog
Number
Catalog
Number
Catalog
Number
Catalog
Number
Two-Pole
100 KD2100 HKD2100 KDC2100 KT2100T TA300K
2
125 KD2125 HKD2125 KDC2125 KT2125T TA300K
2
150 KD2150 HKD2150 KDC2150 KT2150T TA300K
2
175 KD2175 HKD2175 KDC2175 KT2175T TA300K
2
200 KD2200 HKD2200 KDC2200 KT2200T TA300K
2
225 KD2225 HKD2225 KDC2225 KT2225T TA300K
2
250 KD2250 HKD2250 KDC2250 KT2250T TA350K
2
300 KD2300 HKD2300 KDC2300 KT2300T TA350K
2
350 KD2350 HKD2350 KDC2350 KT2350T TA350K
2
400 KD2400 HKD2400 KDC2400 KT2400T 2TA400K
3
Three-Pole
100 KD3100 HKD3100 KDC3100 KT3100T TA300K 2
125 KD3125 HKD3125 KDC3125 KT3125T TA300K
2
150 KD3150 HKD3150 KDC3150 KT3150T TA300K
2
175 KD3175 HKD3175 KDC3175 KT3175T TA300K
2
200 KD3200 HKD3200 KDC3200 KT3200T TA300K
2
225 KD3225 HKD3225 KDC3225 KT3225T TA300K
2
250 KD3250 HKD3250 KDC3250 KT3250T TA350K
2
300 KD3300 HKD3300 KDC3300 KT3300T TA350K
2
350 KD3350 HKD3350 KDC3350 KT3350T TA350K
2
400 KD3400 HKD3400 KDC3400 KT3400T 3TA400K
3
Four-Pole
100 KD4100 HKD4100 KDC4100 KT3100T TA300K 2
125 KD4125 HKD4125 KDC4125 KT3125T TA300K
2
175 KD4175 HKD4175 KDC4175 KT3175T TA300K
2
200 KD4200 HKD4200 KDC4200 KT3200T TA300K
2
225 KD4225 HKD4225 KDC4225 KT3225T TA300K
2
250 KD4250 HKD4250 KDC4250 KT3250T TA350K
2
300 KD4300 HKD4300 KDC4300 KT3300T TA350K
2
350 KD4350 HKD4350 KDC4350 KT3350T TA350K
2
400 KD4400 HKD4400 KDC4400 KT3400T 4TA400K
3
V1-T5-118 Volume 1—Residential and Light Commercial CA08100002E—September 2012 www.eaton.com
5
5.11 Metering Products
Group Metering
1MM and 3MM Metering Stack Modules
Residential Meter Stacks
Features, Benefits and Functions
A. Barrier
Meter socket and tenant
main breaker/wireway
sections are separated by a
solid metal barrier to guard
unmetered bus against
power theft.
B. Tenant Breaker
Reliable bus bar-to-bus bar
connection. 200A modules
accept bolt-on breakers 60–
200A. 125A modules accept
15–125A plug-on breakers.
C. Moveable Phase Connector
Four-wire horizontal bus lets
you use any 3MM module
for single- or three-phase
incoming service. Shipped
with A and B phase
connection, phase balancing
is easily accomplished in the
field by moving one, front-
accessible phase connector
post per module.
D. Neutral Assembly
A convenient termination for
neutral conductors is in the
wireway of each module.
E. Enclosed Horizontal Bus
Added security because a
non-removable barrier
encloses the 800 or 1200A
horizontal bus passing
through tenant breaker
section.
F. Equipment Ground Bar
Factory installed in side
gutter, a standard feature
that’s moveable to the top or
bottom gutter.
G. Raintight Cap
Shipped on each outdoor
meter module and main
device.
H. Knockouts
Tangential in bottom endwall.
I. Superior Finish
Rust inhibiting phosphate
primer and gray baked
enamel is standard. All
outdoor enclosures are of
galvanized steel construction.
J. Meter Socket
Our unique meter socket
base is installed without any
fasteners—reducing chances
for hot spots, easily
replaceable, and improves
connection to vertical bus.
K. Bus Connection
Mains and modules slip
together quickly and
smoothly with front-
accessible captive bolts
securing the juncture without
removing socket interiors or
bus access plate. Main bus
joint bolts torque to 25 foot
pounds.
L. Separate Wireway Cover
Separate covers allow easy
access to tenant breaker and
wireway section, permit work
on breakers or in wireway
without disturbing meters or
meter covers. (Not shown.)
M. Vertical Bus Bar
One-piece vertical bus bar
from phase balancing joints to
meter socket eliminating any
chance for hot spots.
1MM Meter Stack Module
K
F
E
A
B
G
M
J
C
H
D
I
Volume 1—Residential and Light Commercial CA08100002E—September 2012 www.eaton.com V1-T5-119
5
5.11Metering Products
Group Metering
●Eaton’s 1MM stacks are
single-phase in, single-
phase out design
●Eaton’s 3MM stacks are
three-phase in, single-
phase out design
●Stacks with single-phase
horizontal bus are rated
240/120V, single-phase,
three-wire. Stacks with
three-phase horizontal bus
are rated 208Y/120V, three-
phase, four-wire, but can
be used on 240/120V,
three-phase, four-wire
delta systems
●All three-phase horizontal
bus modules have four-
wire cross bus, connected
A-B phase to vertical bus,
readily reconnectable for
phase balance on
installation
Note: Individual sockets cannot be
phase balanced, only each stack.
●Short-circuit ratings up to
100,000A rms symmetrical
depending upon AIC rating
of installed main tenant
circuit breakers and
main device
●Main tenant feeders can
exit bottom or back.
Knockouts are available
at all exit locations
●If being used in outdoor
application and exiting the
top, mount Myer type hubs
on rainproof cap
●Provision for two-pole
breaker (plug-on type for
125A sockets and bolt-on
type for 200A sockets)—
circuit breakers not
included
●Mechanically and
electrically built to bolt-up
with main service modules
and commercial modular
metering stacks
●Aluminum or copper bus
●800 or 1200A horizontal
bus
●All 3MM stacks include
fifth jaw at 9 o’clock
position
●All 1MM stacks do not
include fifth jaw. Order
1MM5JK if needed
Catalog Number Selection
When Ordering:
1. Determine catalog number of Main Service Module.
2. Determine catalog number of Meter Stack (Residential or Commercial).
3. Find quantity and catalog numbers for tenant circuit breakers (found on Page V1-T5-127 or V1-T5-137).
Order one breaker per socket.
4. If any accessories are needed, order from Pages V1-T5-138 and V1-T5-139.
Phases
1 = Single-phase
3 = Three-phase
Options
Blank = Ring
RL = Ringless
RLB = Ringless with horn bypass
WB = Wall bracket (accessory)
BSK = Bussed spacer (accessory)
EB12 = 12-inch (304.8 mm) elbow (accessory)
EB16 = 16-inch (406.4 mm) elbow (accessory)
Number of Meters
2, 3, 4, 5 or 6
Blank = Accessory
Bus Type
Blank = Aluminum
C = Copper
Type of Metering
MM = Multiple metering
Ampere Rating
12 = 125A
20 = 200A
Blank = Accessory
Enclosure
R = Outdoor
Blank = Indoor
Bus Amperes
12 = 200A horizontal bus (3MM units only)
Blank = Standard 800A bus
1 MM 4 12 R 12 C
V1-T5-120 Volume 1—Residential and Light Commercial CA08100002E—September 2012 www.eaton.com
5
5.11 Metering Products
Group Metering
Product Selection
800A Horizontal Aluminum Bus—Standard Offering
Notes
1 For indoor applications where a top endwall with knockouts is needed, order one of part number MM12N1WLK for each 125A stack
or MM20N1WLK for each 200A stack.
2 1MM units do not come with 5th jaw.
3 To change in field from ring to ringless—order 1MMRC125.
4 To change in field from ring to ringless, the top socket in 125A, two- and three-high stacks use 1MMRC125T. Top socket only—other sockets see 3.
5 To change in field from ring to ringless—order 1MMRC200.
6 Check with local utility for height requirements or restrictions.
Amperes
Per
Meter
Socket
Number of
Meter
Sockets
Bus
Ampacity
Enclosure
Type 1
Main Tenant Breaker Type
(For Specific Catalog Numbers,
Refer to Page V1-T5-127)
Single-Phase In,
Single-Phase Out
Three-Phase In,
Single-Phase Out
Single-Phase Horizontal Bus
(Three Horizontal Bus Bars—
A, B and Neutral) 2
Three-Phase Horizontal Bus
(Four Horizontal Bus Bars—
A, B, C and Neutral)
Catalog Number Catalog Number
Ring Style Meter Socket Covers
125 3 2 4 800 Indoor/outdoor BR2_
BRH2_
BRHH2_
Use three-phase 3MM212R
3 4 800 Indoor/outdoor 1MM312R 3MM312R
4 800 Indoor/outdoor 1MM412R 3MM412R
5 800 Indoor/outdoor 1MM512R 3MM512R
6 800 Indoor/outdoor 1MM612R 3MM612R
200 5 2 800 Outdoor CCV2_X, CHH2_H2X
CHH2_H4X, CHH2_X
Use three-phase 3MM220R
3 800 Outdoor 1MM320R 3MM320R
4 800 Outdoor 1MM420R 3MM420R
5 800 Outdoor 1MM520R 6 3MM520R 5
Ringless Style Meter Socket Covers
125 2 800 Outdoor BR2_
BRH2_
BRHH2_
Use three-phase 3MM212RRL
3 800 Outdoor 1MM312RRL 3MM312RRL
4 800 Outdoor 1MM412RRL 3MM412RRL
5 800 Outdoor 1MM512RRL 3MM512RRL
6 800 Outdoor 1MM612RRL 3MM612RRL
200 2 800 Outdoor CCV2_X, CHH2_H2X
CHH2_H4X, CHH2_X
Use three-phase 3MM220RRL
3 800 Outdoor 1MM320RRL 3MM320RRL
4 800 Outdoor 1MM420RRL 3MM420RRL
5 800 Outdoor 1MM520RRL 6 3MM520RRL 5
Ringless Style Covers with Horn Bypass
125 2 800 Outdoor BR2_
BRH2_
BRHH2_
Use three-phase 3MM212RRLB
3 800 Outdoor 1MM312RRLB 3MM312RRLB
4 800 Outdoor 1MM412RRLB 3MM412RRLB
5 800 Outdoor 1MM512RRLB 3MM512RRLB
6 800 Outdoor 1MM612RRLB 3MM612RRLB
200 2 800 Outdoor CCV2_X, CHH2_H2X
CHH2_H4X, CHH2_X
CHH2_H4X, CHH2_X
Use three-phase 3MM220RRLB
3 800 Outdoor 1MM320RRLB 3MM320RRLB
4 800 Outdoor 1MM420RRLB 3MM420RRLB
5 800 Outdoor 1MM520RRLB 6 3MM520RRLB 5
1MM and 3MM
Metering Stack
Modules
V1-T5-124 Volume 1—Residential and Light Commercial CA08100002E—September 2012 www.eaton.com
5
5.11 Metering Products
Group Metering
Dimensions
Approximate Dimensions in Inches (mm)
Modular Metering Stacks—Aluminum and Copper
1MM, 3MM, 125 Amperes
Note: Dimensions Apply to 800 and 1200 Ampere Horizontal Bus.
This Bus
Omitted
On 1 —
PH Units
41.80
(1061.7)9.00(228.6)9.00(228.6)12.61(320.2)3.07
(78.0)(6) KO for
1, 1-2/4 1-1/2
Conduit
A
7.01
(178.0)34.25(870.0)To of Wall Mtg. ScrewCL21.65(550.0)C Meter to C Rail Mounting ScrewLL2.00
(50.8)TYP.
2, 3 Meter Device 4 Meter Device30.0(777.2)To C of Main Bus BarL48.50(1231.9)12.60(320.3)9.00(228.6)9.00(228.6)9.00(228.6)30.60
(777.2)To C of Main Bus BarL57.50
(1460.5)9.00(228.6)9.00(228.6)9.00(228.6)12.60(320.0)To C of Main Bus BarL30.60
(777.2)
5 Meter Device 6 Meter Device12.60(320.0)9.00(228.6)9.00(228.6)9.00(228.6)9.00(228.6)9.00(228.6)66.50
(1689.1)
A
30.60
(777.2)To C of Main Bus BarLTop End & Bottom End View for NEMA 1;
Bottom End View for NEMA 3R
Tangential K.O.'s
3/4, 1, 1-1/4, 1-1/2
"Z" = C OF 1-1/2" Ring
"Y" = C OF 1 1/4" Ring
"X" = C OF 3/4" & 1" RingLLL
0.125
(3.2)
12.13
(308.1)
2.83
(71.9)
2.83
(71.9)
2.83
(71.9)
2.33
(59.1)
6.62
(168.1)
2.83
(71.9)
6.06
(153.9)
2.83
(71.9)
2.83
(71.9)
12.26
(311.4)
12.26
(311.4)
12.26
(311.4)
12.26
(311.4)
"X"
"Y""Z"
Volume 1—Residential and Light Commercial CA08100002E—September 2012 www.eaton.com V1-T5-127
5
5.11Metering Products
Group Metering
BR2100/CC2200
1MM and 3MM Metering Circuit Breakers
1MP, 1MM and 3MM Main Tenant Circuit Breakers
Product Description
Specific main tenant circuit
breakers that are to be
used in meter packs (1MP),
residential meter stacks
(1MM) and three-phase in
single-phase out meter
stacks (3MM).
Features, Benefits
and Functions
1MP, 1MM and 3MM Main
Tenant Circuit Breakers
●The following Eaton
breakers are to be used
on 1MP, 1MM and 3MM
modular metering stacks
●Series rating information
available on Pages V1-T5-
144 through V1-T5-147
●120/240 Vac—field
installed
●Three-phase, 400–1200A
main circuit breakers
●Three-phase, 400–800A
main fusible switches
●Simple bridge joint
connection
Product Selection
Aluminum Bus—Main Lugs Not Included—See Page V1-T5-98
Description
Number
of Poles
Main Tenant
Circuit Breaker
Ampere Rating
10 kAIC 22 kAIC 25 kAIC 42 kAIC 100 kAIC
Catalog
Number
Catalog
Number
Catalog
Number
Catalog
Number
Catalog
Number
Plug-on type circuit breakers used with 1MP, 1MM and
3MM 125A modular metering stacks
260BR260 BRH260 — BRHH260 —
270BR270 BRH270 — BRHH270 —
280BR280 BRH280 —BRHH280 —
290BR290 BRH290 —BRHH290 —
2100BR2100 BRH2100 —BRHH2100 —
2110BR2110 BRH2110 —BRHH2110 —
2125BR2125 BRH2125 —BRHH2125 —
Bolt-on type circuit breakers used with 1MP, 1MM and
3MM 200A modular metering stacks
260——CHH2060H2X CHH2060H4X CHH2060X
270——CHH2070H2X CHH2070H4X CHH2070X
280——CHH2080H2X CHH2080H4X CHH2080X
290——CHH2090H2X CHH2090H4X CHH2090X
2100CCV2100X —CHH2100H2X CHH2100H4X CHH2100X
2125CCV2125X —CHH2125H2X CHH2125H4X CHH2125X
2150CCV2150X —CHH2150H2X CHH2150H4X CHH2150X
2175CCV2175X —CHH2175H2X CHH2175H4X CHH2175X
2200CCV2200X —CHH2200H2X CHH2200H4X CHH2200X
V1-T1-76 Volume 1—Residential and Light Commercial CA08100002E—September 2014 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.2 Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers
Product Selection
Plug-On Circuit Breakers, Types BR—10/22/42 kAIC, 120 Vac, 120/240 Vac and 240 Vac
Type BR Breakers, 1-Inch (25.4 mm) per Pole 120/240, 10, 22 and 42 kAIC
Notes
1 One pole, 1-inch (25.4 mm) per pole circuit breakers are available with high magnetic setting for switching large tungsten lamp loads. Add suffix H to catalog number.
2 Switching duty rated.
3 On the black handle breaker, add suffix “B” to the catalog number to obtain a tapped molded opening for proper use with hold-down kits.
4 For use as a branch circuit breaker in 400 and 600 ampere panels only.
All Type BR single-, two- and three-pole circuit breakers carry listing for HACR application. For circuit breakers with a shunt trip, add ST suffix.
Ampere
Rating
Wire Size Range
Cu/Al 60 °C or 75 °C
Single-Pole 120/240 Vac
Requires One 1-Inch (25.4 mm) Space
Two-Pole 120/240 Vac
Common Trip Requires Two
1-Inch (25.4 mm) Spaces
10 per Shelf Carton 5 per Shelf Carton
10 kAIC 22 kAIC 10 kAIC 22 kAIC 42 kAIC 65 kAIC
Catalog
Number
Catalog
Number
Catalog
Number
Catalog
Number
Catalog
Number
Catalog
Number
10 #14–4 BR110 — BR210 — — —
15 #14–4 BR115 12 BRH115 BR215
3 BRH215 — —
20 #14–4 BR120 12 BRH120 BR220
3 BRH220 — —
25 #14–4 BR125 BRH125 BR225
3 BRH225 — —
30 #14–4 BR130 BRH130 BR230
3 BRH230 — —
35 #14–4 BR135 BRH135 BR235
3 BRH235 — —
40 #14–4 BR140 BRH140 BR240
3 BRH240 3 ——
45 #14–4 — BRH145 BR245
3 BRH245 — —
50 #14–4 BR150 BRH150 BR250
3 BRH250 3 ——
55 #14–3 BR150 BRH155 BR255 BRH255 — —
60 #8–1/0 BR160 BRH160 BR260 BRH260 BRHH260 BRX260
70 #8–1/0 BR170 BRH170 BR270 BRH270 BRHH270 BRX270
80 #8–1/0 — — BR280 BRH280 BRHH280 BRX280
90 #8–1/0 — — BR290 BRH290 BRHH290 BRX290
100 #8–1/0 — — BR2100 BRH2100 BRHH2100 BRX2100
110 #8–1/0 — — BR2110 BRH2110 BRHH2110 BRX2110
125 #4–2/0 — — BR2125 BRH2125 BRHH2125 BRX2125
150 #4–2/0 — — BR2150
4 ———
BR120
BR215
BR320
BRH2100
BRX2125
Volume 1—Residential and Light Commercial CA08100002E—September 2012 www.eaton.com V1-T5-103
5
5.11Metering Products
Group Metering
Main Service Modules
Product Description
●Main terminal box
●Main circuit breaker
●Main bolted pressure
switch
●Main fusible switch
●Main fusible switch with
pull box
●Underground pull box
Application Description
Main Circuit Breakers with
Busway Connections
The Service Entrance Product
Team announces the
availability of both main
fusible switch and main
circuit breaker group
metering mains with busway
connections. This offering
provides us with the ability
to offer multiple tenant
metering in high rise
apartment buildings where
riser busway is used.
Features, Benefits and Functions
Eaton’s Main Service Module
●Offering: main terminal/lug
compartment, main circuit
breaker, main fusible
switch, main bolted
pressure switch, main
fusible switch with pull
box (meets EUSERC
electrical requirements),
underground pull box
termination compartment
without cross bus (meets
EUSERC electrical
requirements)
●Mechanically and
electrically built for use
with 1MM, 3MM, 35MM,
37MM, 35SS and 37SS
modular metering stacks
●For integrated system
short-circuit ratings with
main devices, see series
ratings on Page V1-T5-144
●All main service modules
include both left and right
horizontal bus closure
plates
●Two-pole devices are
applied to single-phase,
three-wire, 120/240V or
208Y/120V systems, three-
pole devices to 208Y/240V
or 120/240V delta systems
●Single-phase mains couple
to any modular metering
stack (1MM, 3MM, 35MM,
37MM, 35SS and 37SS)
●Three-phase mains require
three-phase bussed stacks.
These modular metering
stacks are 3MM, 35MM,
37MM, 35SS and 37SS
●If the ampere rating of the
main service module is
greater than the horizontal
bus rating of the meter
stack (residential or
commercial), the main
service module must be
center fed. Examples:
1200A Main Circuit Breaker
(1MCB1200R) with an
800A residential stack
(1MM512R). 1600A Main
Terminal Box
(3MTB1600R) with a
1200A residential stack
(3MM212R12)
●Most main service
modules are available with
aluminum or copper bus
Main Circuit Breakers with
Busway Connections
●Three-phase, 400–200A
main circuit breakers
●Three-phase, 400–800A
main fusible switches
●Simple bridge joint
connection
●Variety of options:
●Right or left mounting
●Internal ground or
housing ground
●The MFS/MCB and busway
connector are supplied
completely assembled
V1-T5-104 Volume 1—Residential and Light Commercial CA08100002E—September 2012 www.eaton.com
5
5.11 Metering Products
Group Metering
Catalog Number Selection
When Ordering:
1. Determine catalog number of Main Service Module.
2. Determine catalog number of Meter Stack (Residential or Commercial).
3. Find quantity and catalog numbers for tenant circuit breakers (found on Page V1-T5-127 or V1-T5-137).
Order one breaker per socket.
4. If any accessories are needed, order from Pages V1-T5-138 and V1-T5-139.
Phase
1 = Single-phase
3 = Three-phase
Ampere Rating
400A
600A
800A
1000A
1200A
1400A
1600A
2000A
Bus Material
C = Copper bus
Blank= Aluminum bus
Type of Metering
BTB = Main terminal box
MCB = Main circuit breaker
BPS = Bolted pressure switch
MFS = Main fusible switch
UGPB = Underground pull box
MTBE =Main terminal box with utility
pull box
MCBE =Main circuit breaker with utility
pull box
Accessories and Additional Options
BLK= Box lug kit (accessory)
CLK= Compression lug (accessory)
B = Bottom feed
T = Top feed
UG= Pull box
Blank= No options
Enclosure
R = NEMA 3R
3 MTB 400 R C
V1-T5-108 Volume 1—Residential and Light Commercial CA08100002E—September 2012 www.eaton.com
5
5.11 Metering Products
Group Metering
Main Fusible Switches
●Fuses not included
●Main lugs and neutral
included with device
●100 kAIC rating on
switches with Class T
fuses installed. If
converting to Class H, the
kAIC rating is 10 and if
converted to Class R, the
kAIC rating is 200
Note: This is the fuse rating,
switch still rated at 100 kAIC.
●800A top and bottom fed
units are supplied with
Class T fuse clips as
standard. The Class T fuse
clips are field convertible to
Class L by repositioning.
No kit is needed
●Barrier kits available
for 400A–800A
fusible switches:
Bottom feed—3MFSBBK,
Top feed—3MFSTBK
Main Fusible Switches
Notes
1 If Class H fuse clips are needed, use catalog number WCG3HK400 (order (1) per phase).
If Class R fuse clips are needed, order catalog number DS56FK in addition to WCG3HK400.
In order to go from T to R, the device must first be converted to H.
All kits are field installable and each DS56FK kit will convert three poles.
2 If Class H fuse clips are needed, use catalog number WCG3HK600 (order (1) per phase).
If Class R fuse clips are needed, order catalog number DS66FK in addition to WCG3HK600.
In order to go from T to R, the device must first be converted to H.
All kits are field installable and each DS66FK kit will convert three poles.
3 Class T fuse clips provided are field convertible to Class L by repositioning. No kit is needed.
4 If compression lugs are being used, order 3MFS800CLK. This compression lug kit includes four pads (three poles and neutral).
5 1MFS600BLK (4) 3/0–750 kcmil/phase (one kit/phase and one kit/neutral).
6 If compression lugs are being used, order 3MFS800CLKT. This compression lug kit includes four pads (three poles and neutral).
7 IMFS1200LK (3) 750 kcmil/phase (one kit/phase). IMFS1200LKN (3) 750 kcmil (neutral).
Ampere
Rating Feed
Class Fuse
Clips (Fuses
Not Included)
Line Side Box Lugs and Wire Sizes
(Included with Switch)
System Voltage
120/240 Vac
Single-Phase,
Three-Wire
120/208 Vac
Three-Phase,
Four-Wire
Catalog Number Catalog Number
Aluminum Bus (Standard Offering)
400 Bottom T
1 (2) 1/0–300 kcmil or (1) 750 kcmil 45 1MFS400RB 3MFS400RB
400 Top T 1 (2) 1/0–300 kcmil or (1) 750 kcmil 56 1MFS400RT 3MFS400RT
600 Bottom T
2 (2) #2–600 kcmil 45 1MFS600RB 3MFS600RB
600 Top T 2 (2) #2–600 kcmil 56 1MFS600RT 3MFS600RT
800 Bottom T, L
3 (4) 3/0–750 kcmil 4 1MFS800RB 3MFS800RB
800 Top T, L 3 (4) 3/0–750 kcmil 6 1MFS800RT 3MFS800RT
1200 Bottom T, L
3 (4) #2–600 kcmil 7 1MFS1200RB 3MFS1200RB
Copper Bus (Premium Offering)
400 Bottom T
1 (2) 1/0–300 kcmil or (1) 750 kcmil 45 1MFS400RBC 3MFS400RBC
400 Top T 1 (2) 1/0–300 kcmil or (1) 750 kcmil 56 1MFS400RTC 3MFS400RTC
600 Bottom T
2 (2) #2–600 kcmil 45 1MFS600RBC 3MFS600RBC
600 Top T 2 (2) #2–600 kcmil 56 1MFS600RTC 3MFS600RTC
800 Bottom T, L
3 (4) 3/0–750 kcmil 4 1MFS800RBC 3MFS800RBC
800 Top T, L 3 (4) 3/0–750 kcmil 6 1MFS800RTC 3MFS800RTC
1200 Bottom T, L
3 (4) #2–600 kcmil 7 1MFS1200RBC 3MFS1200RBC
Main Fusible Switches
V1-T5-112 Volume 1—Residential and Light Commercial CA08100002E—September 2012 www.eaton.com
5
5.11 Metering Products
Group Metering
Dimensions
Approximate Dimensions in Inches (mm)
Dimensions (Not to be Used for Construction Purposes)
Main Device
Width Height Depth Mounting
Center Line of
Wall Mounting
Bracket
Knockouts in Bottom Endwalls Except No
KOs for Top Feed Switch or Bolted Pressure
Switch Conduit Diameter KO
Dwg.ABCDEF Inches mm
Terminal Box
400 and 600A 13.50 (342.9) 48.75 (1238.3) 7.00 (177.8) —54.00 (1371.6) 30.63 (777.9)(1) 2.50, 3.00, 3.50, 4.00
(1) 0.50
(1) 63.5, 76.2, 88.9, 101.6
(1) 12.7
1
800 and 1200A 20.00 (508.0) 47.63 (1209.8) 11.75 (298.5) 12.00 (304.8) 51.50 (1308.1) 30.63 (777.9)(2) 0.50, 0.75, 1.00
(4) 2.00, 2.50, 3.00, 3.50, 4.00
(2) 12.1, 19.1, 25.4
(4) 50.8, 63.5, 76.2, 88.9, 101.6
2
1600A 32.88 (835.2) 60.13 (1527.3) 11.44 (290.6) 16.00 (406.4) 64.13 (1628.9) 38.59 (980.2)(1) 0.75, 1.00, 1.25, 1.50
(5) 3.00, 3.50, 4.00, 5.00
(1) 19.1, 25.4, 31.8, 38.1
(5) 76.2, 88.9, 101.6, 127.0
3
Main Circuit Breaker with Box Lugs
400–1200A 20.00 (508.0) 47.63 (1209.8) 11.75 (298.5) 12.00 (304.8) 51.50 (1308.1) 30.63 (777.9)(2) 0.50, 0.75, 1.00
(4) 2.00, 2.50, 3.00,3.50, 4.00
(2) 12.7, 19.1, 25.4
(4) 50.8, 63.5, 76.2, 88.9, 101.6
2
1400–2000A 24.88 (632.0) 57.13 (1451.0) 14.88 (378.0) 16.00 (406.4) 57.13 (1451.0) 44.00 (1117.6)———
Main Circuit Breaker with Compression Lugs
400–1200A 20.00 (508.0) 61.00 (1549.4) 11.75 (298.5) 12.00 (304.8) 65.00 (1651.0) 44.00 (1117.6)(2) 0.50, 0.75, 1.00
(4) 2.00, 2.50, 3.00, 3.50, 4.00
(2) 12.7, 19.1, 25.4
(4) 50.8, 63.5, 76.2, 88.9, 101.60
2
Main Fusible Switch
Bottom feed
400–800A
20.00 (508.0) 47.63 (1209.8) 11.75 (298.5) 12.00 (304.8) 51.50 (1308.1) 30.63 (777.9)(2) 0.50, 0.75, 1.00
(4) 2.00, 2.50, 3.00, 3.50, 4.00
(2) 12.7, 19.1, 25.4
(4) 50.8, 63.5, 76.2, 88.9, 101.6
2
Top feed
400–800A
20.00 (508.0) 47.63 (1209.8) 11.75 (298.5) 12.00 (304.8) 51.50 (1308.1) 18.13 (460.4)(2) 0.50, 0.75, 1.00
(4) 2.00, 2.50, 3.00, 3.50, 4.00
(2) 12.7, 19.1, 25.4
(4) 50.8, 63.5, 76.2, 88.9, 101.6
2
1200A 33.50 (850.9) 52.75 (1339.9) 11.88 (301.8) 16.00 (406.4) 56.25 (1428.8) 30.75 (781.1)(5) 3.50, 4.00, 5.00
(1) 0.75, 1.00, 1.25, 1.50
(5) 88.9, 101.6, 127.0
(1) 19.1, 25.4, 31.8, 38.1
4
Bolted Pressure Switch
36.50 (927.1) 66.50 (1689.1) 19.50 (495.3) 28.00 (711.2) 60.00 (1524.0) 30.63 (777.9)———
Main Fusible Switch with Pull Box
400A 20.00 (508.0) 61.00 (1549.4) 11.75 (298.5) 12.00 (304.8) 65.00 (1651.0) 44.00 (1117.6)(2) 0.50, 0.75, 1.00
(4) 2.00, 2.50, 3.00, 3.50, 4.00
(2) 12.7, 19.1, 25.4
(4) 50.8, 63.5, 76.2, 88.9, 101.6
2
600 and 800A
(single-phase)
20.00 (508.0) 61.00 (1549.4) 11.75 (298.5) 12.00 (304.8) 65.00 (1651.0) 44.00 (1117.6)(2) 0.50, 0.75, 1.00
(4) 2.00, 2.50, 3.00, 3.50, 4.00
(2) 12.7, 19.1, 25.4
(4) 50.8, 63.5, 76.2, 88.9, 101.6
2
600 and 800A
(three-phase)
25.06 (636.5) 61.00 (1549.4) 11.75 (298.5) 17.00 (431.8) 65.00 (1651.0) 44.00 (1117.6)(2) 0.50, 0.75, 1.00
(4) 2.00, 2.50, 3.00, 3.50, 4.00
(2) 12.7, 19.1, 25.4
(4) 50.8, 63.5, 76.2, 88.9, 101.6
4
1200A 33.50 (850.9) 61.50 (1562.1) 11.88 (301.8) 16.00 (406.4) 65.25 (1657.4) 48.00 (1219.2)(5) 3.50, 4.00, 5.00
(1) 0.75, 1.00, 1.25, 1.50
(5) 88.9, 101.6, 127.0
(1) 19.1, 25.4, 31.8, 38.1
4
Main Circuit Breaker with Pull Box (EUSERC)
400A 20.01 (508.2) 60.44 (1535.2) 11.14 (283.0) 12.00 (304.8) 65.11 (1653.8) 39.75 (1009.6)(4) 2.50, 3.00, 3.50, 4.00 (4) 63.5, 76.2, 88.9, 101.6 2
800A 24.88 (632.0) 60.94 (1547.9) 11.14 (283.0) 17.00 (431.8) 64.88 (1648.0) 39.81 (1011.2)(4) 2.50, 3.00, 3.50, 4.00 (4) 63.5, 76.2, 88.9, 101.6 2
1200A 33.00 (838.2) 61.14 (1553.0) 11.32 (287.5) 16.00 (406.4) 65.25 (1657.4) 43.56 (1106.4)(4) 2.50, 3.00, 3.50, 4.00 (4) 63.5, 76.2, 88.9, 101.6 4
Pull Box
400A 16.38 (416.1) 44.88 (1140.0) 7.88 (200.2) 8.00 (203.2) 45.75 (1162.1) 28.63 (727.2)(2) 4.00 101.6 5
800A 24.38 (619.3) 46.88 (1190.8) 11.88 (301.8) 12.00 (304.8) 47.75 (1212.9) 32.25 (819.2)(3) 4.00 101.6 6
1200A 32.50 (825.5) 56.88 (1444.8) 12.00 (304.8) 17.75 (450.9) 57.75 (1466.9) 42.25 (1073.2)(4) 5.00 127.0 7
EUSERC Bussed Pull Section
Single-phase
400 and 800A
20.13 (511.3) 61.00 (1549.4) 11.25 (285.8) 12.00 (304.8) 64.88 (1648.0) 44.00 (1117.6)(4) 2.50, 3.00, 3.50, 4.00 (4) 63.5, 76.2, 88.9, 101.6 5
Three-phase
400 and 800A
25.13 (638.3) 61.00 (1549.4) 11.88 (301.8) 17.00 (431.8) 64.88 (1648.0) 44.00 (1117.6)(4) 2.50, 3.00, 3.50, 4.00 (4) 63.5, 76.2, 88.9, 101.6 6
EUSERC Main Terminal Box
Single-phase
400 and 800A
20.13 (511.3) 61.00 (1549.4) 11.88 (301.8) 12.00 (304.8) 64.88 (1648.0) 44.00 (1117.6)(2) 0.50, 0.75, 1.00 (2) 12.7, 19.1, 25.4 2
Three-phase
400A
20.13 (511.3) 61.00 (1549.4) 11.88 (301.8) 12.00 (304.8) 64.88 (1648.0) 44.00 (1117.6)(4) 2.00, 2.50, 3.00, 3.50, 4.00 (4) 50.8, 63.5, 76.2, 88.9, 101.6 2
Three-phase
800A
25.13 (638.3) 61.00 (1549.4) 11.88 (301.8) 17.00 (431.8) 64.88 (1648.0) 44.00 (1117.6)(4) 2.00, 2.50, 3.00, 3.50, 4.00 (4) 50.8, 63.5, 76.2, 88.9, 101.6 2
Volume 1—Residential and Light Commercial CA08100002E—September 2012 www.eaton.com V1-T5-113
5
5.11Metering Products
Group Metering
Approximate Dimensions in Inches (mm)
Main Circuit Breakers, Terminal Boxes and Pull Boxes
Top Feed Fusible Switch
Bottom Feed Fusible Switch and Combination Fusible
Switch with Pull Box
Bolted Pressure Switch
EUSERC Main Terminal Box
C
B
A
E
D
Main CB, Non-Euserc Terminal Box and Pullboxes
F
C
17.00
(431.8)
A
E B
D
Top Feed Switch (No Knockouts)
F
Bottom Feed Switch and Combination Switch/Pullbox
A
E B
D
C
17.00
(431.8)
F
D
BE
A
25.00
(635.0)
F
C
A
B
C
V1-T5-114 Volume 1—Residential and Light Commercial CA08100002E—September 2012 www.eaton.com
5
5.11 Metering Products
Group Metering
Approximate Dimensions in Inches (mm)
Knockout 1
Knockout 2
Knockout 3
Knockout 4
Knockout 5
Knockout 6
Knockout 7
Knockout 8
.875
.020
.169+.003
–.000 Diameter 5 Hole
.175
.010
Stamped
ID Mark
5.375
.010 3.500
.010
2.880
.010
KO (44)
KO (1)
12.375 .010
3.010
.010
2.880
.030
2-1/2”, 3”, 3-1/2”, 4” KO
1 Knockout Required
1/2”Knockout
1 Required
Per 50-1827-1 .080
.0202.500
.020
.310 .030 Diameter
Paint Hole.080
.020
.438
.010
.800
.030
.625
.010
6.500 Outside .010CL
8.00
2 Knockouts for 1/2”,
3/4” or 1” Conduit
4 Knockouts for 2-1/2”,
3”, 3-1/2” or 4” Conduit
.281 Diameter Knockout
1 Required
A
.45
3.25 2.50 1.75
4.25
.16
22.54
11.62
10.382.50
3.75
1.93
.61
19.40
8.00
4.00
11.19
2.125
.020
6.000
.010
6.000
.010
6.000
.010
6.000
.010
6.000
.010
6.000
.010
6.000
.010
6.000
.010
6.000
.010
3/4”, 1”, 1-1/4”, 1-1/2” Knockout
Per A50-26319 1 Knockout Required
32.120 .020
3”, 3-1/2”, 4”, 5”
Knockout Per A50-26327
5 Knockouts Required
.380
.020
2.750
.010
2.750
.010
2.750
.010
4.000
.020
7.500
.020
2.125
.020
1.440
.020
.169 .002 Diameter
5 Holes Required at ”X”
1.500
.020
.130
.030
.125
.030
4.440
.020
8.00
22.54
11.62
10.382.50
19.40
8.00
4.00
3.75
1.93
.61
11.19
.45
3.25 2.50 1.75
4.25
2 Knockouts for 1/2”,
3/4” or 1” Conduit
4 Knockouts for 2-1/2”,
3”, 3-1/2” or 4” Conduit
.281 Diameter Knockout
1 Required
.16
B
6.000
.020
KO (10)
KO (10)
5.000
.020
.150 .020
Typ.3.250
.020
3.000
.020
.150 .020 Typ.
6.120
.020
6.850
.020
7.000
+.000
–.030
.780 .020 Typ.
.200
.020
Typ.
KO (10)
.150 .020
Typ.
KO (10)
KO (10)
6.000
.020
6.000
.020
6.000
.020
.250
Ref.
.150
.020
Typ.
4.000
.020
4.250
.020
.250
Ref.
.220
Dia.
Paint
Hole
10.120
.020
10.850
.020
11.000
+.000 -.030
.200 .020
Typ..780 .020
Typ.
7.250
.020
7.250
.020
7.250
.020
5.125
.020
.350
Ref.
.150
.020
Typ.
4.000
.020
4.250
.020
.350
Ref.
.220
Dia.
Paint
Hole
.150 .020
Typ.
KO (11)
KO (11)
KO (11)
KO (11)
10.140
.020
10.850
.020
11.000
+.000
–.030
.120
.020
Typ..685 .020
Typ.
4 Knockouts for 2-1/2",
3", 3-1/2" or 4" Conduit
8.00 4.00
8.00
24.38
11.251.75
2.13
15.38 3.75
16.63
27.13
2.50
3.63
0.50
4.75 3.13 2.50
1.50
4.25 1.75
.281 Dia. Knockout 1 Required
2 Knockouts for
1/2", 3/4", or 1" Conduit
2 Knockouts for
1/2", 3/4", or 1" Conduit
Detail Bill of Material Page 1 of 1
Project Name: STONE QUARRY Negotiation No: SY880507X4K1
General Order
No: Alternate No: 0003
Item No. Qty Product Description
1 Panelboards 42Circuits, 225A, Series Rated, 208Y/120V 3Ph 4W, Aluminum
Bus, 65k AIC, 225A, MLO-Upstream ED[Top Fed], Surface
Mounted
Catalog No P1A225LT42AH01
Designation LAUNDRY
Qty List of Materials
1 225A, MLO-Upstream ED
1 45A, 2P BAB Branch Breaker
16 15A, 1P BAB Branch Breaker
15 20A, 1P BAB Branch Breaker
7 1P BAB Branch Provision Only
1 15A, 2P BAB Branch Breaker
1 Std. Bolted Al Ground Bar (Al/Cu Cable)
1 Panel Nameplate - White with Black Letters
1 Type 1 Enclosure: EZB2042R
1 EZ Trim, Door in Door, Concealed Hardware: EZT2042S
Item No. Qty Product Description
1 Panelboards 42Circuits, 400A, Series Rated, 208Y/120V 3Ph 4W, Aluminum
Bus, 65k AIC, 400A, MLO-Upstream HKD[Top Fed], Surface
Mounted
Catalog No P3A400LT50AH01
Designation MDP
Qty List of Materials
1 400A, MLO-Upstream HKD
1 Shunt Trip (48-127Vac)
1 Auxiliary Switch, (1A/1B)
1 200A, 3P ED Branch Breaker
18 20A, 1P BAB Branch Breaker
5 15A, 2P BAB Branch Breaker
8 1P BAB Branch Provision Only
1 150A, 3P ED Branch Breaker
1 Std. Bolted Al Ground Bar (Al/Cu Cable)
1 Panel Nameplate - White with Black Letters
1 Type 1 Enclosure: EZB2090R
1 EZ Trim, Door in Door, Concealed Hardware: EZT2090S
Eaton Selling Policy 25-000 applies.
All orders must be released for manufacture within 90 days of date of order entry. If approval drawings are required, drawings must be returned
approved for release within 60 days of mailing. If drawings are not returned accordingly, and/or if shipment is delayed for any reason, the price of the
order will increase by 1.0% per month or fraction there of for the time the shipment is delayed.
1 2
3 4
5 6
7 8
9 10
11 12
13 14
15 16
17 18
19 20
21 22
23 24
25 26
27 28
29 30
31 32
33 34
35 36
37 38
39 40
41 42
Main Lugs Only
225A
BAB2045 BAB1020
BAB1020
BAB1020 BAB1020
BAB1020 BAB1020
BAB1020 BAB1020
BAB1020 BAB1020
BAB1020 BAB1020
BAB1020 BAB1020
BAB1020 BAB2015
BAB1015
BAB1015 BAB1015
BAB1015 BAB1015
BAB1015 BAB1015
BAB1015 BAB1015
BAB1015 BAB1015
BAB1015 BAB1015
BAB1015 BAB1015
BAB1015
Blank Cover
2 inches
PROV
PROV PROV
PROV PROV
PROV PROV
General Information (Section 1 of 1)
Service Voltage:208Y/120V 3Ph 4W Enclosure:Type 1
Bus Rating & Type:225A Aluminum Neutral Rating:225A
Ground Bar:Std. Bolted Aluminum, Al or Cu cable
S.C. Rating:65k A.I.C. Series Rated
Main Device Type:MLO-Upstream ED -Top Cable Entry
Main Terminals:Mechanical -(1) #6-300 kcmil (Cu/Al)
Neutral Terminals:Mechanical -(1) #6-300 kcmil (Cu/Al)
Box Catalog No.:EZB2042R
Trim:EZ Trim, Door in Door, Concealed Hardware (EZT2042S)
Surface Mounted
Box Dimensions:42.00" [1066.8mm]H x 20.00" [1066.8mm]W x 5.75" [146.1mm]D
Min. Gutter Size:Top = 5.5" [139.7mm] Bottom = 5.5" [139.7mm]
Left = 6.0" [152.4mm] Right = 6.0" [152.4mm]
Panel ID Nameplate:(1) LAUNDRY
Type:Plastic, adhesive-backed (2) 208Y/120V 3Ph 4W
Color:White with Black Letters (3)
NEC Lighting & Appliance, UL CTL ***Non-Interchangeable Main Device***
Trim Lock: Standard Lock & Key (Keyed WEM2)
Circuit Directory: Plastic Sleeve with Card
Branch Devices
Qty Poles Trip Frame Amps kAIC
1 2 45 BAB 100 65
16 1 15 BAB 100 65
1 2 15 BAB 100 65
15 1 20 BAB 100 65
7 1 PROV
Device Modifications:
Ref #Description
Notes:
NEG-ALT Number
PREPARED BY DATE
APPROVED BY DATE
VERSION
REVISION DWG SIZE
JOB NAME
DESIGNATION
TYPE
G.O.
DRAWING TYPE
ITEM SHEET
The information on this document is
created by Eaton Corporation. It is
disclosed in confidence and it is only to
be used for the purpose in which it is
supplied.
SY880507X4K1-0003
PETER ANDRELLA 12/17/2014
1.0.0.1
0 A
Eaton
STONE QUARRY
LAUNDRY
PRL1a Customer Approval
1 of 1
1 2
3 4
5 6
7 8
9 10
11 12
13 14
15 16
17 18
19 20
21 22
23 24
25 26
27 28
29 30
31 32
33 34
35 36
37 38
39 40
41 42
43 44
45 46
47 48
49 50
Main Lugs Only
400A
Neutral
BAB1020 BAB1020
PROVBAB1 PROVBAB1
PROVBAB1 PROVBAB1
PROVBAB1 PROVBAB1
PROVBAB1 PROVBAB1
BAB1020 BAB1020
BAB1020 BAB1020
BAB1020 BAB1020
BAB1020 BAB1020
BAB1020 BAB1020
BAB1020 BAB1020
BAB1020 BAB1020
BAB1020
BAB1020
BAB2015
BAB2015BAB2015
BAB2015BAB2015
ED3200
200A
ED3150
150A
Bus Cover
15X
General Information (Section 1 of 1)
Service Voltage:208Y/120V 3Ph 4W Enclosure:Type 1
Bus Rating & Type:400A Aluminum Neutral Rating:400A
Ground Bar:Std. Bolted Aluminum, Al or Cu cable
S.C. Rating:65k A.I.C. Series Rated
Main Device Type:MLO-Upstream HKD -Top Cable Entry
Main Terminals:Mechanical -(2) #4-500 kcmil (Cu/Al)
Neutral Terminals:Mechanical -(2) #4-500 kcmil (Cu/Al)
Box Catalog No.:EZB2090R
Trim:EZ Trim, Door in Door, Concealed Hardware (EZT2090S)
Surface Mounted
Box Dimensions:90.00" [2286.0mm]H x 20.00" [2286.0mm]W x 5.75" [146.1mm]D
Min. Gutter Size:Top = 5.5" [139.7mm] Bottom = 5.5" [139.7mm]
Left = 4" [101.6mm] Right = 4" [101.6mm]
Panel ID Nameplate:(1) MDP
Type:Plastic, adhesive-backed (2) 208Y/120V 3Ph 4W
Color:White with Black Letters (3)
NEC Lighting & Appliance, UL CTL
Trim Lock: Standard Lock & Key (Keyed WEM2)
Circuit Directory: Plastic Sleeve with Card
Branch Devices
Qty Poles Trip Frame Amps kAIC
18 1 20 BAB 100 65
1 3 150 ED 225 65
1 3 200 ED 225 65
8 1 PROVBAB1
5 2 15 BAB 100 65
Device Modifications:
Ref #Description
SNT1RP08K Shunt Trip (48-127Vac)
Ckt #:37
A1X1PK Auxiliary Switch, (1A/1B)
Ckt #:37
Notes:
NEG-ALT Number
PREPARED BY DATE
APPROVED BY DATE
VERSION
REVISION DWG SIZE
JOB NAME
DESIGNATION
TYPE
G.O.
DRAWING TYPE
ITEM SHEET
The information on this document is
created by Eaton Corporation. It is
disclosed in confidence and it is only to
be used for the purpose in which it is
supplied.
SY880507X4K1-0003
PETER ANDRELLA 12/17/2014
1.0.0.1
0 A
Eaton
STONE QUARRY
MDP
PRL3a Customer Approval
1 of 1
Volume 2—Commercial Distribution CA08100003E—April 2014 www.eaton.com V2-T3-7
3
3.3Panelboards and Lighting Control
Pow-R-Line C Panelboards
Pow-R-Line C Panelboards
Product Description
Lighting and Distribution Panelboards
Eaton’s assembled
panelboards are designed for
sequence phase connection
of branch circuit devices. This
allows complete flexibility of
circuit arrangement (single-,
two- or three-pole) to allow
balance of the electrical load
on each phase.
Sturdy, rigid chassis
assembly ensures accurate
alignment of interior with
panel front; prevents flexing
and minimizes possibility
of loosening or damage to
current carrying parts during
and after installation.
Four-point in-and-out
adjustment of panel interior
is provided to meet critical
depth dimensions on
flush installations. This
compensates for possible
misalignment of box at
installation.
Main lugs are mechanical
solderless type and approved
for copper or aluminum
conductors.
Enclosures
Boxes are code-gauge
galvanized steel, which
include a painted box finished
in ANSI-61 light gray to match
the trim.
Standard panelboard cabinets
are designed for indoor use.
Alternate types are available
for indoor and special
purpose applications.
All enclosures are furnished
in accordance with
Underwriters Laboratories
standards and include wiring
gutters with proper wire
bending space. Special
cabinets can be provided
at an additional charge.
The box dimensions shown
are inside dimensions. For
outside dimensions, add
1/4-inch (6.4 mm).
Standard panelboard boxes are
supplied without knockouts
(blank endwalls).
Fronts
Fronts (trims) for all
panelboards are made of
code-gauge steel and have a
high durability ANSI-61 light
gray finish applied by a baked-
on polyester powder coating
paint system.
The fronts for lighting and
appliance branch circuit
panelboards and small power
distribution panelboards
include a door with rounded
corners and concealed
hinges. A flush-type latch and
lock assembly is included.
All locks are keyed alike.
These trims are available in
both surface- and flush-
mounted designs.
EZ Trim Features Standard Door-in-Door
with No Exposed Hardware or
Sharp Edges (no Tools are
Required for Installation)
The Three-Piece Trim for Larger Power
Distribution Panelboards Provides for
Easy Handling and Installation
Fronts for power distribution
panelboards utilize a unique
breaker front cover design
in which each device has a
dedicated bolt-on steel cover.
The individual covers form
a single deadfront for the
panelboard that is used in
conjunction with two wiring
gutter covers to complete the
trim. A door is not finished as
part of the standard offering
on these panelboards but can
be provided, for an additional
charge, using a deeper than
standard box.
V2-T3-8 Volume 2—Commercial Distribution CA08100003E—April 2014 www.eaton.com
3
3.3 Panelboards and Lighting Control
Pow-R-Line C Panelboards
Application Description
Panelboard
Selection Factors
In selecting a panelboard,
the following factors must
be considered:
●Service (voltage and
frequency)
●Interrupting capacity
(fully or series rated)
●Ampere rating of main
●Ampere ratings of
branches
●Environment
Panelboard
Short-Circuit Rating
The short-circuit rating
of Eaton’s assembled
panelboards are test
verified by, and listed with,
Underwriters Laboratories
(UL). Generally, these
ratings are that of the lowest
interrupting rated device in
the panel.
Certain exceptions to this
rule exist where branch
devices have been UL tested
in combination with specific
main devices having a higher
interrupting rating. Where
these defined main devices
and branch breaker
combinations are utilized, the
series short-circuit rating of
the assembled panelboard
will be the same as the
tested rating of the approved
rated main device in series
with the branches. Available
main and branch breaker
combinations are tabulated
starting on Page V2-T3-16.
All combinations shown are
UL tested and listed.
These series ratings apply to
panels having main devices,
or main lug only panelboards
fed remotely by the device
listed in the series ratings
chart as the main, for which
UL listed tests were
conducted.
Service Entrance Equipment
The National Electrical Code
(NEC) requires that:
●A panel used as service
entrance equipment
must be located near
the point where the
supply conductors enter
the building
●A panelboard having main
lugs only shall have a
maximum of six service
disconnects to de-energize
the entire panelboard from
the supply conductors.
Where more than six
disconnects are required,
a main service disconnect
must be provided
●A disconnectable electrical
bond must be provided
between the neutral and
ground
●A service entrance type
UL label must be factory
installed
●Ground fault protection
of equipment shall be
provided for each service
disconnect rated 1000A
or more if the electrical
service is a solidly
grounded wye system of
more than 150V to ground,
but not exceeding 600V
phase-to-phase
Note: Service entrance panels
must be identified as such on
the order.
Panelboard Standards
In 2008, both the National
Electrical Code (Article 408)
and UL 67 were updated
to remove the mandated
42-circuit limitation. Eaton
offers panelboards with more
than 42 circuits for those
jurisdictions that have
adopted the 2008 NEC
or later.
For jurisdictions that have| not
adopted the 2008 or
later version of the National
Electrical Code, the 42-circuit
limitation for Lighting
and Appliance Branch
Panelboards remains in place.
Check with your local code
officials to determine specific
jurisdiction status.
Panelboard Installation
NEC requires that the
operating handle of the
topmost mounted device be
no more than 6 feet 7 inches
(2006.6 mm) above the
finished floor and should be
installed per NEC and
manufacturer’s instructions.
Additional boxes and fronts
are required when the
components required for
one panelboard exceed the
standard box dimensions.
Multi-Section Panelboards
When two or more separate
enclosures are required,
separate fronts for each box
are standard. A common
front can be furnished at
additional charge.
Interconnecting Multi-
Section Panelboards
When a panelboard, for
connection to one feeder,
must be furnished in more
than one section (Box), each
section must be furnished
with main bus and terminals
of the same rating, unless a
main overcurrent device is
provided in each section.
Sub-feed or through-feed
provisions must also be
included (and priced) to
provide connection capability
to the second section.
Note: Sub-feed or through-feed
lugs cannot be used on any
panelboard that is not protected
by a single main overcurrent
device either in the panelboard
or immediately upstream, i.e.,
service entrance panelboards
with main lugs only using the six
disconnect rule.
Volume 2—Commercial Distribution CA08100003E—April 2014 www.eaton.com V2-T3-9
3
3.3Panelboards and Lighting Control
Pow-R-Line C Panelboards
Sub-Feed Lugs
Sub-feed lugs (see figure
below) are one means of
interconnecting multi-section
panels. The sub-feed (second
set of) lugs are mounted
directly beside the main lugs.
These are required in each
section except the last panel
in the lineup. The feeder
cables are brought into the
wiring gutter of the first
section and connected to
the main lugs. Another set
of the same size cables are
connected to the sub-feed
lugs (Section 1) and are
carried over to the main lugs
of the adjacent panel. Cross
connection cables are not
furnished by Eaton. Sub-feed
lugs are only available on main
lug only panels.
Note: Sub-feed lugs may
not be used on main lug only
(six disconnect rule) service
entrance panels.
Sub-Feed Lugs
Through-Feed Lugs
Through-feed lugs (see figure
below) are another method
to interconnect multi-section
panelboards. The incoming
feeder cables are connected
to the main lugs or main
breaker at the bottom of
panel (Section 1). Another
set of lugs (through-feed)
are located at the opposite
end of the main bus. The
interconnecting cables are
connected to the through-
feed lugs in Section 1 and are
carried over to the main lugs
in Section 2. The connection
arrangement could be
reversed, i.e., main lugs at
top; through-feed lugs at
bottom end of panel. Cross
cables are not furnished
by Eaton.
Note: Through-feed lugs
may not be used on main lug
only (six disconnect rule) service
entrance panels.
Through-Feed Lugs
Box Box
Conduit
Neutral Neutral
PanelPanelSection 1 Section 2 Section 1 Section 2
Box Box
Conduit
Neutral
PanelPanelNeutral
Main
Lugs
Thru
Feed
Lugs
Main
Lugs
Cross Cables
Incoming Feeder Cables
Multiple Section Panelboard—Flush Mounted
Shown below is the standard method for flush mounting
multiple section lighting and distribution panelboards using
standard flush trims.
Multiple Section Panelboard Flush Mounted—
Dimensions in Inches (mm)
Overcurrent Protection
The following requirements will be found in the NEC:
Each lighting and appliance branch circuit panelboard shall be
individually protected on the supply side by not more than two
main circuit breakers or two sets of fuses having a combined
rating not greater than that on the panelboard.
Contractor to Mount Boxes
1-1/2-inch (38.1 mm) Apart to
Allow for 3/4-inch (19.1 mm)
Extension on Both Flush Trims
Two Section
Panelboard
(Flush Mounting)
Flush Trim Extends 3/4-inch
(19.1 mm) Beyond Outside
of Box on All Four Sides
Outside Edge of BoxTrim
Wall WallTrim Trim
Conduit Nipple for Cross Wiring by Contractor
3/4
(19.1)
3/4
(19.1)
1 1/2
(38.1)
Top Section
View
3/4
(19.1)
3/4
(19.1)
3/4
(19.1)
3/4
(19.1)
3/4
(19.1)
3/4
(19.1)
3/4
(19.1)
3/4
(19.1)
V2-T3-10 Volume 2—Commercial Distribution CA08100003E—April 2014 www.eaton.com
3
3.3 Panelboards and Lighting Control
Pow-R-Line C Panelboards
Branch Circuit Loading
for Lighting Panels
The size of mains and
branches should be selected
based on the following:
●Motor circuits: NEC
Article 430
●Diversity factor
●Provision for future loading
Exception Number 1:
Individual protection for
a lighting panelboard is not
required when the
panelboard feeder has
overcurrent protection not
greater than that of the
panelboard.
Exception Number 2:
For existing installations,
individual protection for
lighting panelboards is not
required where such
panelboards are used as
service equipment in
supplying an individual
residential occupancy and
where any bus supplying
15 or 20A circuits is protected
on the supply side by an
overcurrent device.
Ambient Temperatures
The primary function of an
overcurrent device is to
protect the conductor
and its insulation against
overheating. In selecting
the size of the devices and
conductors, consideration
should be given to the
ambient temperature
surrounding the conductors
within and external to the
panelboard. Cumulative
heating within the panelboard
may cause premature
operation of the overcurrent
protective devices.
Underwriters Laboratories
test procedures are based,
in part, on 80% loading of
panelboard branch circuit
devices. The NEC limits
the loading of overcurrent
devices in panelboards
to 80% of rating where in
normal operation the load will
continue for three hours or
more. Further derating may
be required, depending on
such factors as ambient
temperature, duty cycle,
frequency or altitude.
Exception: There is one
exception to this rule in both
UL and NEC. It applies to
assemblies and overcurrent
devices that have been listed
for continuous duty at 100%
of its rating.
Special Conditions
Standard panelboards,
assembled with standard
components, are adequate
for most applications.
However, special
consideration should be
given to those required for
application under special
conditions such as:
●Excessive vibration
or shock
●Frequencies above
60 cycles
●Altitudes above 6600 feet
(2011.7m)
●Damp environment
(possible fungus growth)
●Compliance with federal,
state and municipal
electrical codes and
standards
Seismic Considerations
The Uniform Building Code®
and the International Building
Code, as well as local and
state building codes, place
an emphasis on seismic
building design requirements.
Electrical distribution systems
are treated as attachments to
the building and therefore, fall
into this category.
All Eaton panelboards are
seismic qualified at the
highest possible level,
and have been tested in
accordance with ANSI
C37.81. This standard
quantifies actual earthquake
conditions, as well as
equipment seismic capability.
Harmonic Currents
Standard panelboard neutrals
are rated for 100% of the
panelboard current. However,
since harmonic currents can
cause overheated neutrals,
an option is provided for
neutrals to be rated at 200%
(1200A maximum neutral for
600A main bus) of the
panelboard phase current.
Panelboards with the 200%
rated neutral are UL listed as
suitable for use with non-
linear loads.
Prior to specifying the 200%
rated neutral, Eaton
recommends a harmonic
survey be conducted of the
distribution system, be it new
or existing.
Surge Protective Devices
The quality of power feeding
sensitive electronic loads is
critical to the reliable operation
of any facility. In modern
offices, hospitals, and
manufacturing facilities, the
most frequent causes of
microprocessor-based
equipment downtime and
damage are voltage transients
and electrical noise.
Electrical loads and
microprocessor-based
equipment are highly
susceptible to both high and
low energy transients. High
energy transients include
lightning induced surges and
power company switching.
These high energy transients
can destroy components
instantly.
More frequently the electrical
system experiences low
energy transients and high
frequency noise.
The effects of continual low
energy transients and high
frequency noise can cause
erratic equipment
performance or sudden
failure of electronic circuit
board components.
Eaton can provide protective
and diagnostic systems
integral to panelboards.
The surge protective device
(SPD) is integrated into the
panelboards using a “zero
lead length” direct bus bar
connection.
Pow-R-Line 4
The SPD protects sensitive
electronic equipment from the
damaging effects of high and
low energy transients, as well
as high frequency noise.
Standards and
Certifications
Eaton’s panelboards are
designed to meet the
following applicable
industry standards,
except where noted:
●Underwriters Laboratories:
●Panelboards: UL 67
●Cabinets and Boxes:
UL 50
Note: Only panelboards
containing UL listed devices
can be UL labeled.
●National Electrical Code
●NEMA Standards: PB 1
●Federal Specification
W-P-115c:
●Circuit Breakers—
Type I Class I
●Fusible Switch—
Type II Class I
Volume 2—Commercial Distribution CA08100003E—April 2014 www.eaton.com V2-T3-11
3
3.3Panelboards and Lighting Control
Pow-R-Line C Panelboards
Technical Data and Specifications
Panelboard Selection Guide
Note
1 Fixed mounted only.
Maximum
Voltage Rating
Maximum Main
Rating (Amperes)
AC Interrupting Capacity
rms Symmetrical Amperes (kA)
Panelboard
Type
Device
Type AC DC MLO Main Device
Branch Circuits
Ampere Range
Sub-Feed Breaker
Maximum Amperes Fully Rated Series Rated
PRL1a Breaker 240 — 400 400 15–100 400 10–22 22–100
PRL1R Breaker 240 — 225 225 15–100 — 10–22 22–100
PRL1aF Fusible 240 — 400 400 15–30 400 200 —
PRL1a-LX Breaker 240 — 225 225 15–100 — 10–22 22–100
PRL2a Breaker 240 250 400 400 15–100 400 65 65–200
Breaker 480Y/277 250 400 400 15–100 400 14 22–150
PRL2R Breaker 240 — 225 225 15–100 — 10–22 22–200
Breaker 480Y/277 — 225 225 15–100 — 14 22–100
PRL2aF Fusible 480Y/277 — 400 400 15–30 400 200 —
PRL2a-LX Breaker 240 250 225 225 15–100 — 65 65–200
Breaker 480Y/277 250 225 225 15–100 — 14 22–150
PRL3a Breaker 240 250 800 600 15–225 600 10–200 22–200
Breaker 480 250 800 600 15–225 600 14–100 22–150
Breaker 600 250 800 600 15–225 600 14–35 —
PRL3E Breaker 240 250 600 600 15–125 400 25–100 100–200
Breaker 480Y/277 250 600 600 15–125 400 18–65 65–100
Breaker 480 250 600 600 15–125 400 18–65 65–100
PRL4B Breaker 240 600 1200 1200 15–1200 — 10–200 22–200
Breaker 480 600 1200 1200 15–1200 — 14–200 22–150
Breaker 600 600 1200 1200 15–1200 — 14–200 —
PRL4D Breaker 240 — 1200 1200
1 600 —65–200 —
Breaker 480 — 1200 1200
1 600 —35–100 —
Breaker 600 — 1200 1200
1 600 —18–50 —
PRL4F Fusible 240 250 1200 1200 30–1200 —100–200 —
Fusible 600 250 1200 1200 30–1200 —100–200 —
PRL5P Breaker 240 250 1200 1200 15–1200 —10–200 22–200
Breaker 480 250 1200 1200 15–1200 —14–200 22–150
Breaker 600 250 1200 1200 15–1200 —14–200 —
PRC100 PRC25 Breaker 240 — 400 400 15–225 —10–65 22–100
Breaker 480Y/277 — 400 400 15–225 —14 65–100
Elevator Control Fusible 240 — 800 800 15–200 —200 —
Fusible 480Y/277 — 800 800 15–200 —200 —
Fusible 480 — 800 800 15–200 —200 —
Terminal Wire Ranges, Pressure-Type Al/Cu Terminals Except as Noted
Note: All terminal sizes are based
on wire ampacities corresponding
to those shown in NEC Table
310.16 under the 75°C insulation
columns (75°C wire). The use of
smaller size, (in circular mills),
regardless of insulation
temperature rating, is not
permitted.
Where copper-aluminum
terminals are supplied on
designated panelboard types,
best results are obtained if a
suitable joint compound is
applied when aluminum
conductors are used.
Check Eaton’s standard
terminal sizes versus
customer requirements.
In particular, 400 and 800A
breakers often require
nonstandard lugs.
Optional 750 kcmil
mechanical screw-type
terminals are available
upon request. Panelboard
dimensions may be affected,
refer to Eaton.
Volume 2—Commercial Distribution CA08100003E—April 2014 www.eaton.com V2-T3-13
3
3.3Panelboards and Lighting Control
Pow-R-Line C Panelboards
Standard Circuit Breaker Terminals
Breaker Type Ampere Rating Wire Range
BAB, QBHW, BABRSP,
HQP, QPHW
15–70 #14–#4
90–100 #8–1/0
EDB, EDS, ED, EDH, EDC 100–225 #4–4/0 or #6–300 kcmil
EGB, EGE, EGS, EGH 15–50 #14–3/0 AL/CU
60–125 #6–3/0 AL/CU
EHD, FDB, FD,
HFD, FDC, HFDDC 2
15–100 #14–1/0
125–225 #4–4/0
FCL 15–100 #14–1/0
GHB, HGHB, GHQ,
GHQRSP
15–20 #14–#10
25–100 #10–1/0
EGB, EGS, EGH 15–50 #14–1/0
60–125 #6–2/0
JD, HJD, JDC, HJDDC 2 70–250 #4–350 kcmil
DK 250–350 250–500 kcmil
400 (2) 3/0–250 kcmil or (1) 3/0–500 kcmil
KD,
HKD, KDC, HKDDC, 2
CKD, CHKD
225 (1) #3–350 kcmil
350 (2) 3/0–250 kcmil or
400 (2) 3/0–250 kcmil or (1) 3/0–500 kcmil
LHH 150–400 #2–500 kcmil
150–400 (2) #2–500 kcmil
150–400 (1) 500–750 kcmil
LGE, LGH, LGC,
LGU, LHH 1
250–400 (1) #2–500 kcmil
500–600 (2) #2–500 kcmil
LD, HLD, LDC, HLDDC 2
CLD, CHLD
300–500 (2) 250–350 kcmil
600 (2) 400–500 kcmil
MDL, HMDL, HMDLDC 2
CMDL, CHMDL
400–600 (2) #1–500 kcmil
700–800 (3) 3/0–400 kcmil
ND, HND, CND, CHND, NDC,
CNDC
800–1000 (3) 3/0–400 kcmil
1200 (4) 4/0–500 kcmil
LCL 125–225 (1) #6–350 kcmil
250–400 (1) #4–250 kcmil and (1) 3/0–600 kcmil
FB-P 15–100 #14–1/0
LA-P 70–225 #6–350 kcmil
250–400 (1) #4–250 kcmil and (1) 3/0–600 kcmil
NB-P, NBDC 2 300–700 (2) #1–500 kcmil
800 (3) 3/0–400 kcmil
FDPW Switch Terminals
Elevator Control Panel Feeder Terminals
Notes
1 LHH is 400A maximum.
2 Suitable for DC applications only.
Ampere Rating Wire Range
30 #14–1/0
60 #14–1/0
100 #14–1/0
200 #4–300 kcmil
400 250–750 kcmil or (2) 3/0–250 kcmil
600 (2) #4–600 kcmil or (4) 3/0–250 kcmil
800 (3) 250–750 kcmil or (6) 3/0–250 kcmil
1200 (4) 250–750 kcmil or (8) 3/0–250 kcmil
Ampere Rating Wire Range
30 #14–1/0
60 #14–1/0
100 #14–1/0
200 #4–300 kcmil
Detail Bill of Material Page 1 of 1
Project Name: STONE QUARRY Negotiation No: SY880507X4K1
General Order
No: Alternate No: 0003
Item No. Qty Product Description
1 Safety Switches Safety Switches
Catalog No DH324FGK
Designation ELEV
Qty List of Materials
1 Auxiliary Contact Kit : 1NO/1NC - DS200EK1 (Field Installed)
1 Heavy Duty Switch - Fusible, 3-Pole, 240 VAC, 200 A, NEMA 1
Item No. Qty Product Description
1 Safety Switches Safety Switches
Catalog No DG221NGB
Designation ELEV
Qty List of Materials
1 General Duty Switch - Fusible, 3-Wire, 240 VAC, 30 A, NEMA 1
Eaton Selling Policy 25-000 applies.
All orders must be released for manufacture within 90 days of date of order entry. If approval drawings are required, drawings must be returned
approved for release within 60 days of mailing. If drawings are not returned accordingly, and/or if shipment is delayed for any reason, the price of the
order will increase by 1.0% per month or fraction there of for the time the shipment is delayed.
Safety Switch General Information
Global Specifications
System Voltage 240 VAC
Switch Type Single Throw -Heavy Duty
Poles/Blades 3-Pole
Amperage 200
Protection Fusible with No Neutral
Enclosure Type NEMA 1
Fuse Clips Standard
Switch Lugs Standard
Fungus Proof Treatment N
Lock-On Provision N
Fuse Pullers N
Control Pole N
Ground Lugs N
316 Stainless N
Stainless Mechanism N
Mill Duty N
Nameplate
Field Installed Kits
QUANTITY DESCRIPTION
1 Auxiliary Contact Kit : 1NO/1NC -DS200EK1 (Field
Installed)
Safety Switch Catalog No.
DH324FGK
NEG-ALT Number
PREPARED BY DATE
APPROVED BY DATE
VERSION
REVISION DWG SIZE
JOB NAME
DESIGNATION
TYPE
G.O.
DRAWING TYPE
ITEM SHEET
The information on this document is
created by Eaton Corporation. It is
disclosed in confidence and it is only to
be used for the purpose in which it is
supplied.
SY880507X4K1-0003
PETER ANDRELLA 12/17/2014
1.0.0.1
0 A
Eaton
STONE QUARRY
ELEV
Safety Switch General Information Customer Appr.
1 of 1
GO/NEG-Alt-Date: Job Name:
Item Number: Catalog Number: Designation:
SY880507X4K1-0003-12/17/2014 STONE QUARRY
DH324FGK ELEV
Safety Switch General Information
Global Specifications
System Voltage 240 VAC
Switch Type Single Throw -General Duty
Poles/Blades 2-Pole
Amperage 30
Protection Fusible with Neutral
Enclosure Type NEMA 1
Fuse Clips Standard
Switch Lugs Standard
Fungus Proof Treatment N
Lock-On Provision N
Fuse Pullers N
Control Pole N
Ground Lugs N
316 Stainless N
Stainless Mechanism N
Mill Duty N
Nameplate
Safety Switch Catalog No.
DG221NGB
NEG-ALT Number
PREPARED BY DATE
APPROVED BY DATE
VERSION
REVISION DWG SIZE
JOB NAME
DESIGNATION
TYPE
G.O.
DRAWING TYPE
ITEM SHEET
The information on this document is
created by Eaton Corporation. It is
disclosed in confidence and it is only to
be used for the purpose in which it is
supplied.
SY880507X4K1-0003
PETER ANDRELLA 12/17/2014
1.0.0.1
0 A
Eaton
STONE QUARRY
ELEV
Safety Switch General Information Customer Appr.
1 of 1
Date PDF Generated:9/28/2012 Page: 1 of 1 GO/NEG-Alt-Date: Job Name:
Item Number: Catalog Number: Designation:
SY880507X4K1-0003-12/17/2014 STONE QUARRY
DG221NGB ELEV
Catalog Number Selection
Safety Switch
Notes
1 Always verify the number of poles and wires required since catalog numbers may appear in multiple tables.
2 See Pages V2-T1-17 through V2-T1-20 for additional Flex Center options.
3 Effective August 2003, 30–100A window switches are replaced by a full view window that allows blade position verification and blown fuse indication. See Page V2-T1-37 for catalog numbers.
This table is intended for use in breaking down existing catalog numbers. It is not intended for building new catalog numbers.
Series
K = Design all general-duty switches
above 200A and all heavy-duty
switches incorporate K-Series
switch design features listed below
B = Design general-duty 30–100A
H = General-duty double-throw switch
(compact design 30–100A)Fusible/Non-Fusible or Neutral
F = Fusible without neutral
U = Non-fusible
N = Fusible with neutral
NEMA Enclosure Ratings
G = NEMA 1
R = NEMA 3R
D = NEMA 12 or 12/3R
P = NEMA 4 (painted steel)
W = NEMA 4X (corrosion-resistant
(304 Grade stainless steel)
C = NEMA 4X non-metallic
(for Type DH)
X = NEMA 7/9 (for Type DS)
X = NEMA 4X non-metallic
(for Type DR)
Switch Type
DP = General-duty/plug fuse
DG = General-duty/cartridge fuse
DH = Heavy-duty
DT = Double-throw
DR = Rotary switch
DS = Classified location with
DS interior
Voltage
1 = 120 Vac
2 = 240 Vac
6 = 600 Vac
Ampere Rating
1 = 30A
2 = 60A
3 = 100A
4 = 200A
5 = 400A
6 = 600A
7 = 800A
8 = 1200A
Options 2
W = Upper viewing window
3
LW = Lower viewing window
3
X = EnviroLine stainless
(enclosure and mechanism)
GCL = Mill-duty
Poles/Blades
1 = 1-pole
2 = 2-pole
3 = 3-pole
4 = 4-pole
6 = 6-pole
DH 3 6 1 N D K LW
Quick Connect Double-Throw
Notes
1 When upper and lower switches are the same, the switch configuration is consolidated in one letter (e.g., “U” not “UU”). Also, a switch with a neutral will have either a solid neutral or a switched
neutral, not both. Lastly, a switched neutral pole is never fused.
2 This field is only used when a switch is completely non-fused.
Switch Type
DT = Heavy-duty
double-throw
DH = Heavy-duty
single-throw
Poles
2 = Two-pole
3 = Three-pole
4 = Four-pole
Maximum
Voltage
2 = 240 Vac
6 = 600 Vac
Switch
Ampacity
3 = 100A
4 = 200A
5 = 400A
6 = 600A
7 = 800A
Upper Switch 1
U = Unfused
F = Fusible
N = Fusible with
solid neutral
SN = Fusible with
switched neutral
Series
K= K
DT 3 6 5 N U R K LC
Enclosure
G = NEMA 1
R= NEMA 3R
Receptacle Type
LC = Cam-Lok
LCR = Cam-Lok
reverse pin
LP =Posi-Lok
LPR = Posi-Lok
reverse pin
Neutral
Blank = No neutral or
incl. with switch
designation
N = Solid neutral
SN = Switched neutral
Lower Switch 2
U = Unfused
F = Fusible
N = Fusible with
solid neutral
SN = Fusible with
switched neutral
V2-T1-24 Volume 2—Commercial Distribution CA08100003E—May 2012 www.eaton.com
1
1.1 Switching Devices
Safety Switches
Cartridge Fuse General-Duty Safety Switch
General Duty
Product Description
●30–600A
●Suitable for service
entrance applications
unless otherwise noted
●Fusible and non-fusible
switches are 100% load
break and 100% load
make rated
●The continuous load
current of fusible switches
is not to exceed 80%
of the rating of fuses
employed in other than
motor circuits. Non-fusible
switches are 100%
fully rated
●200–600A features
K-Series design
●Horsepower rated
●Fusible and non-fusible
switches. Single-pole
S/N through four-wire;
120/240, and 240 Vac
●With Class R fuses,
switches may be used
on systems capable of
delivering 100,000A rms
symmetrical
Note: Plug fuse switches are not
service entrance rated.
120/240 Vac General-Duty,
Fusible, Single-Throw
●30–600A
●Suitable for service
entrance applications
unless otherwise noted
●Horsepower rated
●Bolt-on hub provision.
Provided for general-duty
switches in a NEMA 3R
enclosure. See Page V2-T1-
21 for selection
●200–600A switches
incorporate K-Series
design
Non-Fusible Switches
The UL listed short-circuit
ratings for Eaton’s non-fusible
switches are based on the
switches being properly
protected by overcurrent
protective devices. For
applications that require a
UL listed short-circuit rating
of 10,000A rms symmetrical
or less, an Eaton non-fusible
switch must be properly
protected by any overcurrent
protective device rated no
greater than the ampere
rating of the switch.
For applications that require a
UL listed short-circuit rating
of greater than 10,000 rms
symmetrical amperes, an
Eaton non-fusible switch
must be properly protected
by the appropriate class and
size fusing noted on the
switch publication (located
on the inside cover).
Otherwise, this non-fusible
switch must be replaced with
an Eaton fusible switch that
utilizes the appropriate fusing
required. Molded case circuit
breaker protection of non-
fusible Eaton switches for
applications that require
a short-circuit rating of
greater than 10,000A rms
symmetrical has not been
evaluated. Refer to the
reference tables for typical
Eaton fusible switch UL listed
short-circuit ratings.
Note: Safety switch short-circuit
ratings are applicable to AC only.
Safety switch l2t and lp values
are identical to UL maximum
acceptable l2t and lp values for
the corresponding class fuse.
Application Description
For residential and
commercial applications.
Suitable for light-duty motor
circuits and service entrance.
Volume 2—Commercial Distribution CA08100003E—May 2012 www.eaton.com V2-T1-25
1
1.1Switching Devices
Safety Switches
Features, Benefits and Functions
General-Duty (Cartridge Fuse)
●Ample wire bending
space provides for
easier installation
●Visible double-break quick-
make, quick-break rotary
blade mechanism
●Side opening door on
all enclosures
●Mechanically interlocked
cover to prevent easy
access when the switch
is in the ON position
●With Class R fuses,
switches may be used
on systems capable of
delivering 100,000A rms
symmetrical
●Clearly visible and
accessible neutral
where applicable
●Visible ON/OFF indication
●Tangential knockouts on
30–60A designs
●Ample wiring space
●Double padlocking
capability on 30–100A
●Triple padlocking capability
on 200–600A
●Additional door locking
capability
●Bilingual English/Spanish
door label on 30–100A
●Tri-lingual nameplates
All general-duty switches
above 100A and all heavy-
duty switches incorporate
these K-Series switch design
features.
●Two points of contact
provide a positive
open and close, easier
operation, and also help
prevent contact burning
for longer contact life
Visible Double-Break Rotary
Blade Mechanism
●Protects against accidental
contact with energized
parts. Probe holes enable
the user to test if the line
side is energized without
removing the shield.
Not typically provided
on general-duty switches,
but available as a field kit
or factory installed
Clear Line Shield
●Provide easy removal
of fuses
Built-In Fuse Pullers (NEMA 12
and 4X 30–200A Only)
●The position (ON or OFF)
can be clearly seen from
a distance and the length
provides for easy operation
Clearly Visible Handle
●Personnel safety feature
since the large hasp can
accommodate up to
three 3/8-inch (9.5 mm)
shank locks
Triple Padlocking Capability
●Cabinet door can be further
padlocked at the top and
bottom as applicable
Additional Locking Capability
●Door cannot be opened
when the handle is in the
ON position. Front and
side operable defeater
mechanism provides
for user access when
necessary on single-
throw switches
Interlocking Mechanism
●An ample number are
provided on the top,
bottom and sides of both
NEMA Types 1 and 3R
enclosures through 200A
Tangential Knockouts
●For switches in a NEMA
Type 3R, 30–200A. Use
a Myers type hub for
all others
Bolt-On Hub Kits
Standards and Certifications
●UL listed File No. E5239
●Meets UL 98 for enclosed
switches and NEMA Std.
KS-1
Volume 2—Commercial Distribution CA08100003E—May 2012 www.eaton.com V2-T1-21
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.1Switching Devices
Safety Switches
Technical Data and Specifications
Standard Lug Capacities
Dimensions
Approximate Dimensions in Inches (mm)
Plate Type Hubs
For NEMA 3R enclosures (up to 200A)
Catalog number DS900AP adapter kit permits Installation of Group 1 hubs on
200A type general-duty, heavy-duty and double-throw switches.
Notes
1 The maximum size aluminum or copper-clad aluminum wire allowable for applications where the conductor enters
or leaves the enclosure through the wall opposite its terminal is #1 gauge.
Although certain lug capacities are larger than required, only minimum wire bending space is provided per the
requirements noted in NEC® Tables 373-6 (a) and (b) for respective ampere ratings.
Description
Minimum
Wire Size
Maximum
Wire Size Wire Type
30A DP #14
#12
#10
#10
Cu or
Al
30A DG #14 #6 Cu/Al
30A DH, DT #14 #2 Cu/Al
60A DG #14 #1/0 Cu/Al
60A DH, DT #14 #2 Cu/Al
100A DG 1 #14 #1/0 Cu/Al
100A DH, DT #14 #1/0 Cu/Al
200A DG, DT #6 250 kcmil Cu/Al
200A DH Type 1 and 3R #6 250 kcmil Cu/Al
200A DH Type 4 and 12 #6 300 kcmil Cu/Al
400A DG, DH, DT (2) #1/0
(1) #1/0
(2) 300 kcmil
(1) 750 kcmil
Cu/Al or
Cu/Al
600A DG, DH, fusible DT (1) #2
(1) #1/0
(1) 600 kcmil
(1) 750 kcmil
Cu/Al and
Cu/Al
600A non-fusible DT (2) #250 (2) 500 kcmil Cu/Al
800A DH (4) #1/0 (4) 750 kcmil Cu/Al
800A DT (3) #250 (3) 500 kcmil Cu/Al
1200A DH, DT (4) #1/0 (4) 750 kcmil Cu/Al
Copper-Bodied Lugs
30A Cu #14 #6 Cu
60A Cu #14 #4 Cu
100A Cu #6 #1/0 Cu
200A Cu #6 250 kcmil Cu
400A Cu #1/0 500 kcmil Cu
600A Cu (2) #1/0 (2) 500 kcmil Cu
Group 1
General-Duty, Heavy-Duty,
Double-Throw Through 100A
Group 2
General-Duty, Heavy-Duty,
Double-Throw—200A
Catalog Number Conduit Size Catalog Number Conduit Size
DS075H1 0.75 (19.1)DS200H2 2.00 (50.8)
DS100H1 1.00 (25.4)DS250H2 2.50 (63.5)
DS125H1 1.25 (31.8)DS300H2 3.00 (76.2)
DS150H1 1.50 (38.1)——
DS200H1 2.00 (50.8)——
DS075H1
Volume 2—Commercial Distribution CA08100003E—May 2012 www.eaton.com V2-T1-29
1
1.1Switching Devices
Safety Switches
Heavy-Duty Safety Switch
Heavy-Duty
Product Description
●30–1200A
●600 Vac, 600 Vdc
maximum
●Horsepower rated
●Fusible and non-fusible
switches are 100% load
break and 100% load
make rated
●The continuous load
current of fusible switches
is not to exceed 80%
of the rating of fuses
employed in other than
motor circuits. Non-fusible
switches are 100%
fully rated
●Suitable for service
entrance applications
unless otherwise noted
240 Vac Heavy-Duty, Fusible,
Single-Throw
●30–1200A
●Horsepower rated
●Suitable for service
entrance use, except
four-pole switches
●For factory modifications,
refer to Pages V2-T1-17
through V2-T1-20
600 Vac Heavy-Duty, Fusible,
Single-Throw
●30–1200A
●Horsepower rated
●Suitable for service
entrance use, except
1200A on 480Y/277 or
600Y/347 grounded
wye systems, per
NEC 215.10 and 230.95,
and four-pole switches
●For factory modifications,
refer to Pages V2-T1-17
through V2-T1-20
600 Vac Heavy-Duty, Non-
Fusible, Single-Throw
●30–1200A
●Horsepower rated
●Suitable for service
entrance use, except
1200A on 480Y/277V or
600Y/347V grounded wye
systems, per NEC 215.10
and 230.95, and four-pole
switches
●For factory modifications,
refer to Pages V2-T1-17
through V2-T1-20
Application Description
For heavy commercial and
industrial applications where
reliable performance and
service continuity are critical.
For the toughest heavy
commercial and industrial
applications, refer to
Page V2-T1-77 for catalog
information on our
mill-duty safety switch
V2-T1-30 Volume 2—Commercial Distribution CA08100003E—May 2012 www.eaton.com
1
1.1 Switching Devices
Safety Switches
Features, Benefits and Functions
●Visible double-break quick-
make, quick-break rotary
blade mechanism. Two
points of contact provide
a positive open and close,
easier operation, and
also help prevent contact
burning for longer
contact life
●Triple padlocking capability.
Personnel safety feature
since the large hasp can
accommodate up to three
3/8-inch (9.5 mm) shank
locks. Cabinet door can be
further padlocked at the
top and bottom
●Interlocking mechanism.
Door cannot be opened
when the handle is in the
ON position. Built-in
defeater mechanism
provides for user access
when necessary
●Deionizing arc chutes;
arc chutes confine and
suppress the arcs
produced by opening
contacts under load
●Mechanically interlocked
cover to prevent easy
access when the switch
is in the ON position
●Clear line shield with
probe holes
●Clearly visible palm fitting
red handle
●Tangential knockouts on
NEMA 1 and NEMA 3R
enclosures through 200A
●Built-in fuse pullers on
NEMA 4X and NEMA 12
enclosures through 200A
●Additional door locking
capability
●Complete accessory and
renewal parts data shown
on inner door label.
●30–800A NEMA 12
designs convertible to
NEMA 3R by opening
factory-installed drain hole
●30–1200A switches are
seismic qualified and
exceed the requirements
of the Uniform Building
Code® (UBC) and California
Code Title 24
●Tri-lingual nameplates
All general-duty switches
above 100A and all heavy-
duty switches incorporate
these K-Series switch
design features.
●Two points of contact
provide a positive
open and close, easier
operation, and also help
prevent contact burning
for longer contact life
Visible Double-Break Rotary
Blade Mechanism
●Protects against accidental
contact with energized
parts. Probe holes enable
the user to test if the line
side is energized without
removing the shield.
Not typically provided
on general-duty switches,
but available as a field kit
or factory installed
Clear Line Shield
●Provide easy removal
of fuses
Built-In Fuse Pullers (NEMA 12
and 4X 30–200A Only)
●The position (ON or OFF)
can be clearly seen from
a distance and the length
provides for easy operation
Clearly Visible Handle
●Personnel safety feature
since the large hasp can
accommodate up to
three 3/8-inch (9.5 mm)
shank locks
Triple Padlocking Capability
●Cabinet door can be further
padlocked at the top and
bottom as applicable
Additional Locking Capability
●Door cannot be opened
when the handle is in the
ON position. Front and
side operable defeater
mechanism provides
for user access when
necessary on single-
throw switches
Interlocking Mechanism
●An ample number are
provided on the top,
bottom and sides of both
NEMA Types 1 and 3R
enclosures through 200A
Tangential Knockouts
●For switches in a NEMA
Type 3R, 30–200A. Use
a Myers type hub for
all others
Bolt-On Hub Kits
Standards and Certifications
●UL listed File No. E5239
●Meets UL 98 for enclosed
switches and NEMA
Std. KS-1
Volume 2—Commercial Distribution CA08100003E—May 2012 www.eaton.com V2-T1-21
1
1.1Switching Devices
Safety Switches
Technical Data and Specifications
Standard Lug Capacities
Dimensions
Approximate Dimensions in Inches (mm)
Plate Type Hubs
For NEMA 3R enclosures (up to 200A)
Catalog number DS900AP adapter kit permits Installation of Group 1 hubs on
200A type general-duty, heavy-duty and double-throw switches.
Notes
1 The maximum size aluminum or copper-clad aluminum wire allowable for applications where the conductor enters
or leaves the enclosure through the wall opposite its terminal is #1 gauge.
Although certain lug capacities are larger than required, only minimum wire bending space is provided per the
requirements noted in NEC® Tables 373-6 (a) and (b) for respective ampere ratings.
Description
Minimum
Wire Size
Maximum
Wire Size Wire Type
30A DP #14
#12
#10
#10
Cu or
Al
30A DG #14 #6 Cu/Al
30A DH, DT #14 #2 Cu/Al
60A DG #14 #1/0 Cu/Al
60A DH, DT #14 #2 Cu/Al
100A DG 1 #14 #1/0 Cu/Al
100A DH, DT #14 #1/0 Cu/Al
200A DG, DT #6 250 kcmil Cu/Al
200A DH Type 1 and 3R #6 250 kcmil Cu/Al
200A DH Type 4 and 12 #6 300 kcmil Cu/Al
400A DG, DH, DT (2) #1/0
(1) #1/0
(2) 300 kcmil
(1) 750 kcmil
Cu/Al or
Cu/Al
600A DG, DH, fusible DT (1) #2
(1) #1/0
(1) 600 kcmil
(1) 750 kcmil
Cu/Al and
Cu/Al
600A non-fusible DT (2) #250 (2) 500 kcmil Cu/Al
800A DH (4) #1/0 (4) 750 kcmil Cu/Al
800A DT (3) #250 (3) 500 kcmil Cu/Al
1200A DH, DT (4) #1/0 (4) 750 kcmil Cu/Al
Copper-Bodied Lugs
30A Cu #14 #6 Cu
60A Cu #14 #4 Cu
100A Cu #6 #1/0 Cu
200A Cu #6 250 kcmil Cu
400A Cu #1/0 500 kcmil Cu
600A Cu (2) #1/0 (2) 500 kcmil Cu
Group 1
General-Duty, Heavy-Duty,
Double-Throw Through 100A
Group 2
General-Duty, Heavy-Duty,
Double-Throw—200A
Catalog Number Conduit Size Catalog Number Conduit Size
DS075H1 0.75 (19.1)DS200H2 2.00 (50.8)
DS100H1 1.00 (25.4)DS250H2 2.50 (63.5)
DS125H1 1.25 (31.8)DS300H2 3.00 (76.2)
DS150H1 1.50 (38.1)——
DS200H1 2.00 (50.8)——
DS075H1
Detail Bill of Material Page 1 of 1
Project Name: STONE QUARRY Negotiation No: SY880507X4K1
General Order
No: Alternate No: 0003
Item No. Qty Product Description
39 AC DISCONNECTS 60A/2P Air Conditioning Non-Fused Disconnect 240V
Catalog No DPU222R
Designation ACC'S, DSS'S
Qty List of Materials
39 60A/2P Air Conditioning Non-Fused Disconnect 240V
Eaton Selling Policy 25-000 applies.
All orders must be released for manufacture within 90 days of date of order entry. If approval drawings are required, drawings must be returned
approved for release within 60 days of mailing. If drawings are not returned accordingly, and/or if shipment is delayed for any reason, the price of the
order will increase by 1.0% per month or fraction there of for the time the shipment is delayed.
V1-T7-2 Volume 1—Residential and Light Commercial CA08100002E—August 2012 www.eaton.com
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7.1 Air Conditioning Disconnects
Fused, Unfused and Molded Case Switch
Complete Line of Fused, Unfused and Molded
Case Switch Type Air Conditioning Disconnects
Air Conditioning Disconnects Contents
Description Page
Features, Benefits and Functions. . . . . . . . . . . . . .V1-T7-3
Standards and Certifications . . . . . . . . . . . . . . . . .V1-T7-3
Product Selection. . . . . . . . . . . . . . . . . . . . . . . . . .V1-T7-4
Cross-Reference . . . . . . . . . . . . . . . . . . . . . . . . . .V1-T7-6
Technical Data and Specifications . . . . . . . . . . . . .V1-T7-7
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V1-T7-7
Product Description
An air conditioning
disconnect (ACD) is a
disconnect located between
a loadcenter (distribution
panel) and air conditioner.
Eaton’s ACD product line
provides an installer or repair
personnel with a visible
disconnecting means when
performing maintenance.
ACDs are also known as
disconnects, pullouts or air
conditioning switches.
Non-fused pullout and
molded case switch devices
provide personnel with a
visible ON-OFF disconnecting
means. While fused pullout
units also perform this
function, they also provide an
additional level of protection
for the air conditioner.
Fused and non-fused devices
are of a pullout design, where
the user physically removes
or “pulls out” a tab to break
the electrical connection.
A molded case switch is
similar to a light switch where
the user “switches” the
unit to the indicated
ON-OFF position.
Fused and Non-Fused
Pullouts
●ON/OFF control provided
by a pullout handle
●Pullout handle can be
conveniently stored in the
compartment in the OFF
position, helping to prevent
the handle from being
misplaced
●Protective shield cannot be
removed until the pullout
handle is removed,
disconnecting the power
Molded Case Switch
●Rugged molded case
construction in a
disconnect switch that
looks like a circuit breaker
but operates like an
ordinary household
light switch
●Plug-in molded case switch
(included) eliminates the
need for pullout handles
●No need for replacement
pullout handles due to loss
or theft
Application Description
The most widely used
application for ACDs is for
residential and light
commercial air conditioning
units. An ACD is installed
outdoors, in visible proximity
to the air conditioner
condensing unit. ACDs are
also found in use with heat
pumps, swimming pools,
spas, whirlpools and pump
houses, and meet 2008
NEC Article 422.31 (B)
requirements for servicing
electric water heaters.
Metallic enclosures are
galvanized steel and are
installed in various locations.
Non-metallic enclosures are a
plastic (polycarbonate)
enclosure commonly used in
coastal or salt-water areas.
Volume 1—Residential and Light Commercial CA08100002E—August 2012 www.eaton.com V1-T7-3
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7.1Air Conditioning Disconnects
Fused, Unfused and Molded Case Switch
Features, Benefits and Functions
●Single-phase, two-wire,
240 Vac and three-phase,
three-wire, 240 Vac
●NEMA 3R outdoor
enclosures offered in
metallic and
non-metallic versions
●Easy-to-remove high-
strength protective
shield for easier wiring
and mounting
●Easy-to-remove front cover
(no screws or fasteners to
remove)
●1-inch knockouts on the
bottom, back and side
of unit
●Copper-rated line and load
lugs that are easily
accessible
●Ample wiring space for
mounting with a stud gun
(single keyhole, two- or
three-point mounting)
●Fused devices are service
entrance rated
Note: Fused non-metallic units
require the addition of GB4NM
ground bar to obtain a Service
Entrance rating.
●Horsepower rated (10 hp
maximum at 240 Vac)
●Padlockable door provision
for safety and reduction of
tampering
●Metallic enclosures are
bottom entry and exit only
●Non-metallic enclosures
have knockouts and a hub
provision for top access
●Non-metallic enclosures
have a single unit door and
protective shield for
installer convenience
●Non-metallic enclosures
are durable and provide
excellent resistance to
climate changes
●Factory-installed tamper-
resistant/weather-resistant
receptacles are available as
an option on some products
Standards and
Certifications
●UL listed File No. E132354,
E143893, E196365
Contact Eaton for details
and part numbers for CSA
approved units.
V1-T7-4 Volume 1—Residential and Light Commercial CA08100002E—August 2012 www.eaton.com
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7.1 Air Conditioning Disconnects
Fused, Unfused and Molded Case Switch
Product Selection
Non-Fused Pullouts
Fused Pullouts
For Service Entrance applications, see footnotes below.
Molded Case Switch
Notes
1 For replacement pullout head, order part number 96-3258-4.
2 To obtain a Service Entrance Rating, the addition of a DPFG (ground bar kit) is required.
3 For replacement molded case switch, order part number BR260NA.
Main
Ampere
Rating
Maximum hp Rating Wire Size
Range Cu/Al
60ºC or 75ºC
Catalog
Number120V 240V
Galvanized Steel
60 — 10 #14–3 DPU222R 1
Non-Metallic/Polycarbonate Enclosure
60 — 10 #14–2 ACD222URNM-A2 1
Main
Ampere
Rating
Maximum hp Rating Wire Size
Range Cu/Al
60ºC or 75ºC
Catalog
Number120V 240V
Galvanized Steel
30 2 2 3 #14–3 DPF221R 1
60 2 3 10 #14–3 DPF222R 1
Non-Metallic
30 2 3 #14–2 ACD221RNM-A2 1
60 3 10 #14–2 ACD222RNM-A2 1
Main
Ampere
Rating
Maximum hp Rating Wire Size
Range Cu/Al
60ºC or 75ºC
Catalog
Number120V 240V
Galvanized Steel
60 — 10 #14–3 DPB222R 3
Non-Metallic/Polycarbonate Enclosure
60 — 10 #14–2 B60NARNM-A2 3
DPU222R
DPF222R
DPB222R
Volume 1—Residential and Light Commercial CA08100002E—August 2012 www.eaton.com V1-T7-7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7.1Air Conditioning Disconnects
Fused, Unfused and Molded Case Switch
Technical Data and Specifications
●10,000 amperes rms
symmetrical interrupting
rating
●Horsepower rated
●Fusible and non-fusible
pullout and molded case
switch designs
●30 and 60 amperes
available in fusible
●60 amperes available in
non-fusible and molded
case switch
●Class H fuse clips provided
on fusible pullout design
●WRTR (weather-resistant/
tamper-resistant)
receptacle options
available
Dimensions
Approximate Dimensions in Inches (mm)
Dimensions and Shipping Carton Information
Note
1 Eaton Quick Pro designated item.
Catalog Number
Carton
Quantity
Dimensions in Inches (mm)
Weight Lbs (kg)Height Width Depth
Metallic/Galvanized Steel Enclosure
DPF221R 10 8.70 (220.9) 5.40 (137.2) 3.15 (80.0) 27 (12)
DPF222R 10 8.70 (220.9) 5.40 (137.2) 3.15 (80.0) 27 (12)
DPU222R 10 8.70 (220.9) 5.40 (137.2) 3.15 (80.0) 27 (12)
DPB222R 10 8.60 (218.4) 5.30 (134.6) 3.74 (95.0) 34 (15)
DPU222R12W 1 1 14.75 (374.6) 12.50 (317.5) 4.00 (101.6) 6 (3)
DPU222R34W 1 1 14.75 (374.6) 12.50 (317.5) 4.00 (101.7) 6 (3)
DPU222RGF20 1 13.00 (330.2) 7.50 (190.5) 4.75 (120.7) 8 (4)
DPF221RGF20 1 13.00 (330.2) 7.50 (190.5) 4.75 (120.7) 8 (4)
DPF222RGF20 1 13.00 (330.2) 7.50 (190.5) 4.75 (120.7) 8 (4)
DPU222RGF15 1 13.00 (330.2) 7.50 (190.5) 4.75 (120.7) 8 (4)
DPF221RGF15 1 13.00 (330.2) 7.50 (190.5) 4.75 (120.7) 8 (4)
DPF222RGF15 1 13.00 (330.2) 7.50 (190.5) 4.75 (120.7) 8 (4)
DPF221RGF15WRTR 1 13.00 (330.2) 7.50 (190.5) 4.75 (120.7) 8 (4)
DPF221RGF20WRTR 1 13.00 (330.2) 7.50 (190.5) 4.75 (120.7) 8 (4)
DPF222RGF15WRTR 1 13.00 (330.2) 7.50 (190.5) 4.75 (120.7) 8 (4)
DPF222RGF20WRTR 1 13.00 (330.2) 7.50 (190.5) 4.75 (120.7) 8 (4)
DPU222RGF15WRTR 1 13.00 (330.2) 7.50 (190.5) 4.75 (120.7) 8 (4)
DPU222RGF20WRTR 1 13.00 (330.2) 7.50 (190.5) 4.75 (120.7) 8 (4)
DPU362R 1 8.60 (218.4) 5.30 (134.6) 3.74 (94.9) 4 (2)
Non-Metallic/Polycarbonate Enclosure
ACD221RNM-A2 10 8.63 (219.0) 6.26 (159.0) 4.33 (109.9) 15 (7)
ACD222RNM-A2 10 8.63 (219.0) 6.26 (159.0) 4.33 (109.9) 15 (7)
ACD222URNM-A2 10 8.63 (219.0) 6.26 (159.0) 4.33 (109.9) 15 (7)
B60NARNM-A2 10 8.63 (219.0) 6.26 (159.0) 4.33 (109.9) 18 (8)
V1-T7-8 Volume 1—Residential and Light Commercial CA08100002E—August 2012 www.eaton.com
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7.1 Air Conditioning Disconnects
Fused, Unfused and Molded Case Switch
Approximate Dimensions in Inches (mm)
DPF221R, DPF222R, DPU222R, DPU222R12W and DPU222R34W
5.40
(137.2)
8.79
(223.4)
2.54
(64.4)
3.15
(80.1)
7 Knockouts for 1/2 (12.7),
3/4 (19.1) or 1 (25.4) Conduit
0.28 (7.1) Diameter
Knockout—1 Req‘d.
0.26 (6.5) Dia.
3 Holes Req’d.
0.25
(6.4)
2.00
(50.8)
4.00
(101.6)
1.47
(37.2)
8.70
(221.0)
5.26
(133.6)
5.14
(130.6)
1.11
(28.2)
5.25
(133.5)
1.05
(26.7)
1.50
(38.1)
3.00
(76.2)
0.55
(14.0)
1.13
(28.7)
2.97
(75.3)
2.39
(60.8)
1.13
(28.7)
1.65
(41.9)1.09
(27.7)
1.00
(25.4)
1.55
(39.4)
5.10
(129.5)
1.55
(39.4)
Detail Bill of Material Page 1 of 2
Project Name: STONE QUARRY Negotiation No: SY880507X4K1
General Order
No: Alternate No: 0003
Item No. Qty Product Description
16 BR LOAD CENTERS 1Ph/BR Loadcenter 125A MLO 16/16Cir. Al Bus Nema 1
Catalog No BR1616L125
Designation THP
Qty List of Materials
16 1Ph/BR Loadcenter 125A MLO 16/16Cir. Al Bus Nema 1
Item No. Qty Product Description
16 CH LOAD CENTERS Ground Bar Kit - 21 Terminal
Catalog No GBK21
Designation THP
Qty List of Materials
16 Ground Bar Kit - 21 Terminal
Item No. Qty Product Description
16 BR RESIDENTIAL
BREAKERS
Type BR Breaker 20A/2 Pole 120/240V 10K
Catalog No BR220
Designation THP
Qty List of Materials
16 Type BR Breaker 20A/2 Pole 120/240V 10K
Item No. Qty Product Description
16 BR RESIDENTIAL
BREAKERS
Type BR Breaker 15A/1 Pole 120/240V 10K
Catalog No BR115
Designation THP
Qty List of Materials
16 Type BR Breaker 15A/1 Pole 120/240V 10K
Item No. Qty Product Description
80 BR RESIDENTIAL
BREAKERS
Type BR Breaker 20A/1 Pole 120/240V 10k
Catalog No BR120
Designation THP
Qty List of Materials
80 Type BR Breaker 20A/1 Pole 120/240V 10k
Detail Bill of Material Page 2 of 2
Project Name: STONE QUARRY Negotiation No: SY880507X4K1
General Order
No: Alternate No: 0003
Item No. Qty Product Description
16 BR AFCI BREAKERS TYPE BR COMBINATION AFCI, 1P, 15A, 10KAIC
Catalog No BRCAF115
Designation THP
Qty List of Materials
16 TYPE BR COMBINATION AFCI, 1P, 15A, 10KAIC
Item No. Qty Product Description
48 BR AFCI BREAKERS TYPE BR COMBINATION AFCI, 1P, 20A, 10KAIC
Catalog No BRCAF120
Designation THP
Qty List of Materials
48 TYPE BR COMBINATION AFCI, 1P, 20A, 10KAIC
Detail Bill of Material Page 1 of 2
Project Name: STONE QUARRY Negotiation No: SY880507X4K1
General Order
No: Alternate No: 0003
Item No. Qty Product Description
17 BR LOAD CENTERS 1Ph/BR Loadcenter 125A MLO 16/16Cir. Al Bus Nema 1
Catalog No BR1616L125
Designation AP1
Qty List of Materials
17 1Ph/BR Loadcenter 125A MLO 16/16Cir. Al Bus Nema 1
Item No. Qty Product Description
17 CH LOAD CENTERS Ground Bar Kit - 21 Terminal
Catalog No GBK21
Designation AP1
Qty List of Materials
17 Ground Bar Kit - 21 Terminal
Item No. Qty Product Description
17 BR RESIDENTIAL
BREAKERS
Type BR Breaker 20A/2 Pole 120/240V 10K
Catalog No BR220
Designation AP1
Qty List of Materials
17 Type BR Breaker 20A/2 Pole 120/240V 10K
Item No. Qty Product Description
17 BR RESIDENTIAL
BREAKERS
Type BR Breaker 15A/1 Pole 120/240V 10K
Catalog No BR115
Designation AP1
Qty List of Materials
17 Type BR Breaker 15A/1 Pole 120/240V 10K
Item No. Qty Product Description
85 BR RESIDENTIAL
BREAKERS
Type BR Breaker 20A/1 Pole 120/240V 10k
Catalog No BR120
Designation AP1
Qty List of Materials
85 Type BR Breaker 20A/1 Pole 120/240V 10k
Detail Bill of Material Page 2 of 2
Project Name: STONE QUARRY Negotiation No: SY880507X4K1
General Order
No: Alternate No: 0003
Item No. Qty Product Description
34 BR AFCI BREAKERS TYPE BR COMBINATION AFCI, 1P, 15A, 10KAIC
Catalog No BRCAF115
Designation AP1
Qty List of Materials
34 TYPE BR COMBINATION AFCI, 1P, 15A, 10KAIC
Item No. Qty Product Description
17 BR AFCI BREAKERS TYPE BR COMBINATION AFCI, 1P, 20A, 10KAIC
Catalog No BRCAF120
Designation AP1
Qty List of Materials
17 TYPE BR COMBINATION AFCI, 1P, 20A, 10KAIC
Detail Bill of Material Page 1 of 2
Project Name: STONE QUARRY Negotiation No: SY880507X4K1
General Order
No: Alternate No: 0003
Item No. Qty Product Description
2 BR LOAD CENTERS 1Ph/BR Loadcenter 125A MLO 16/16Cir. Al Bus Nema 1
Catalog No BR1616L125
Designation AP2
Qty List of Materials
2 1Ph/BR Loadcenter 125A MLO 16/16Cir. Al Bus Nema 1
Item No. Qty Product Description
2 CH LOAD CENTERS Ground Bar Kit - 21 Terminal
Catalog No GBK21
Designation AP2
Qty List of Materials
2 Ground Bar Kit - 21 Terminal
Item No. Qty Product Description
2 BR RESIDENTIAL
BREAKERS
Type BR Breaker 20A/2 Pole 120/240V 10K
Catalog No BR220
Designation AP2
Qty List of Materials
2 Type BR Breaker 20A/2 Pole 120/240V 10K
Item No. Qty Product Description
2 BR RESIDENTIAL
BREAKERS
Type BR Breaker 15A/1 Pole 120/240V 10K
Catalog No BR115
Designation AP2
Qty List of Materials
2 Type BR Breaker 15A/1 Pole 120/240V 10K
Item No. Qty Product Description
12 BR RESIDENTIAL
BREAKERS
Type BR Breaker 20A/1 Pole 120/240V 10k
Catalog No BR120
Designation AP2
Qty List of Materials
12 Type BR Breaker 20A/1 Pole 120/240V 10k
Detail Bill of Material Page 2 of 2
Project Name: STONE QUARRY Negotiation No: SY880507X4K1
General Order
No: Alternate No: 0003
Item No. Qty Product Description
4 BR AFCI BREAKERS TYPE BR COMBINATION AFCI, 1P, 15A, 10KAIC
Catalog No BRCAF115
Designation AP2
Qty List of Materials
4 TYPE BR COMBINATION AFCI, 1P, 15A, 10KAIC
Item No. Qty Product Description
2 BR AFCI BREAKERS TYPE BR COMBINATION AFCI, 1P, 20A, 10KAIC
Catalog No BRCAF120
Designation AP2
Qty List of Materials
2 TYPE BR COMBINATION AFCI, 1P, 20A, 10KAIC
4 123
B
C
D
A
B
C
D
3 2
TITLE
SHEET
DRAFTER/DESIGNER DATE (YYYY/MM/DD)
DRAWING
NUMBER
REVISIONSIZEEATON CORPORATION - CONFIDENTIAL AND PROPRIETARY
UNLESS OTHERWISE SPECIFIED
DIMENSIONS IN
SCALE
OF
THIS DOCUMENT, INCLUDING THE DRAWING AND INFORMATION CONTAINED THEREON, IS CONFIDENTIAL AND IS THE EXCLUSIVE
PROPERTY OF EATON CORPORATION, AND IS MERELY ON LOAN AND SUBJECT TO RECALL BY EATON AT ANY TIME. BY TAKING
POSSESSION OF THIS DOCUMENT, THE RECIPIENT ACKNOWLEDGES AND AGREES THAT THIS DOCUMENT CANNOT BE USED IN ANY
MANNER ADVERSE TO THE INTERESTS OF EATON AND THAT NO PORTION OF THIS DOCUMENT MAY BE COPIED OR OTHERWISE
REPRODUCED WITHOUT THE PRIOR WRITTEN CONSENT OF EATON. IN THE CASE OF CONFLICTING CONTRACTUAL PROVISIONS, THIS
NOTICE SHALL GOVERN THE STATUS OF THIS DOCUMENT.
NOTICE TO PERSONS RECEIVING THIS DOCUMENT AND/OR TECHNICAL INFORMATION
C Eaton Corporation, All Rights Reserved
A
DSD_AFM_PORT_ACAD_CUSTOMER.DWG
A
2014 211=6
INCHES
00198-1083
2014/06/27M. EganBR 1" LOADCENTER, MAIN LUG ONLY, INDOOR NEMA 1, 120/240 VAC, 1 PHASE
TYPE BR LOADCENTER RATINGS:
Enclosure: Indoor NEMA 1
Incoming Main: Main Lug Only
Loadcenter Electrical Rating: 120/240 VAC, Single Phase
Bus Bar Ampere: 125 Amps Max
Number of Spaces & Circuits: See Table on Page 2
Incoming Wire Range: #6-2/0
Bus Bar Material: Tin Plated Aluminum (Standard)
Trim Type: Combination (Standard)
Trim Paint: ANSI 61 Light Gray
Short Circuit Rating: See Branch Breaker Ratings
Box Dimensions: 14.3"W x 3.9"D x "A" (See Table on page 2)
FEATURES:
Steel Backpan - For reliable breaker mounting.
Single keyhole mounting - One keyhole at top
and bottom for mounting and leveling.
Split Neutral Bar Assembly - For better
management of load wires.
Drywall marking on Enclosure - Indicates
mounting depth for flush applications
Top or bottom feed - Acceptable for either top or
or bottom applications.
Warranty - 10 year limited warranty on all
BR Loadcenters and Breakers.
OPTIONAL ACCESSORIES:
Catalog Number Description
GBK5 5 POS #14-4 Ground Bar
GBK10 10 POS #14-4 Ground Bar
GBK14 14 POS #14-4 Ground Bar
GBK21 21 POS #14-4 Ground Bar
NL20 Neutral/Ground Lug #2/0 max
BRFP 1" Filler Plate
BREQS125 Hold-down kit for Type BR breaker
BR230SUR BR 2P 30A Circuit Breaker w/ Surge Protection
Ref: 96-3549
14.3 3.9
"A"
Page: 1 of 2
GO/NEG-Alt-Date: Job Name:
Item Number: Catalog Number: Designation:
SY880507X4K1-0003-12/17/2014 STONE QUARRY
BR1616L125 THP
4 123
B
C
D
A
B
C
D
3 2
TITLE
SHEET
DRAFTER/DESIGNER DATE (YYYY/MM/DD)
DRAWING
NUMBER
REVISIONSIZEEATON CORPORATION - CONFIDENTIAL AND PROPRIETARY
UNLESS OTHERWISE SPECIFIED
DIMENSIONS IN
SCALE
OF
THIS DOCUMENT, INCLUDING THE DRAWING AND INFORMATION CONTAINED THEREON, IS CONFIDENTIAL AND IS THE EXCLUSIVE
PROPERTY OF EATON CORPORATION, AND IS MERELY ON LOAN AND SUBJECT TO RECALL BY EATON AT ANY TIME. BY TAKING
POSSESSION OF THIS DOCUMENT, THE RECIPIENT ACKNOWLEDGES AND AGREES THAT THIS DOCUMENT CANNOT BE USED IN ANY
MANNER ADVERSE TO THE INTERESTS OF EATON AND THAT NO PORTION OF THIS DOCUMENT MAY BE COPIED OR OTHERWISE
REPRODUCED WITHOUT THE PRIOR WRITTEN CONSENT OF EATON. IN THE CASE OF CONFLICTING CONTRACTUAL PROVISIONS, THIS
NOTICE SHALL GOVERN THE STATUS OF THIS DOCUMENT.
NOTICE TO PERSONS RECEIVING THIS DOCUMENT AND/OR TECHNICAL INFORMATION
C Eaton Corporation, All Rights Reserved
A
DSD_AFM_PORT_ACAD_CUSTOMER.DWG
A
2014 221=1
INCHES
00198-1083
2014/06/27M. EganBR 1" LOADCENTER, MAIN LUG ONLY, INDOOR NEMA 1, 120/240 VAC, 1 PHASE
LOADCENTER DETAILS
Catalog #Dim "A"Main Lug
Amps
Spaces /
Circuits
Bus
Material
Wire Size
Range Cu/Al
60°C or 75°C
Notes
BR1212L125 16.75 125 12/12 Alum.#6-2/0
BR1224L125 16.75 125 12/24 Alum.#6-2/0
BR1224L125DG 16.75 125 12/24 Alum.#6-2/0 5 ground terminals included plus 2/0 lug
BR1224L125G 16.75 125 12/24 Alum.#6-2/0 8 ground terminals included
BR1224L125P 16.75 125 12/24 Alum.#6-2/0
BR1616L125 18.75 125 16/16 Alum.#6-2/0
BR1624L125 18.75 125 16/24 Alum.#6-2/0
BR1624L125G 18.75 125 16/24 Alum.#6-2/0 10 ground terminals included plus 2/0 lug
BR1624L125GBP 18.75 125 16/24 Alum.#6-2/0 10 ground terminals included plus 2/0 lug
BR2020L125 21 125 20/20 Alum.#6-2/0
BR2024L125 21 125 20/24 Alum.#6-2/0
BR2024L125G 21 125 20/24 Alum.#6-2/0 12 ground terminals included plus 2/0 lug
BR2024L125P 21 125 20/24 Alum.#6-2/0
BR2424L125 23 125 24/24 Alum.#6-2/0
BR2424L125B 23 125 24/24 Alum.#6-2/0
BR2424L125G 23 125 24/24 Alum.#6-2/0 12 ground terminals included plus 2/0 lug
BR2424L125GBP 23 125 24/24 Alum.#6-2/0 12 ground terminals included plus 2/0 lug
BR2430L125G 23 125 24/30 Alum.#6-2/0 14 ground terminals included plus 2/0 lug
BR3042L125 29 125 30/42 Alum.#6-2/0
Note: Catalog Numbers may have addtional characters at the end which describe alternate details, including but not limited to
the following: S, F, W, G, GK, PK, PB, SF, RN, MI, V and #s. Contact sales for those specific details when necessary.
Page: 2 of 2
GO/NEG-Alt-Date: Job Name:
Item Number: Catalog Number: Designation:
SY880507X4K1-0003-12/17/2014 STONE QUARRY
BR1616L125 THP
4 123
B
C
D
A
B
C
D
3 2
TITLE
SHEET
DRAFTER/DESIGNER DATE (YYYY/MM/DD)
DRAWING
NUMBER
REVISIONSIZEEATON CORPORATION - CONFIDENTIAL AND PROPRIETARY
UNLESS OTHERWISE SPECIFIED
DIMENSIONS IN
SCALE
OF
THIS DOCUMENT, INCLUDING THE DRAWING AND INFORMATION CONTAINED THEREON, IS CONFIDENTIAL AND IS THE EXCLUSIVE
PROPERTY OF EATON CORPORATION, AND IS MERELY ON LOAN AND SUBJECT TO RECALL BY EATON AT ANY TIME. BY TAKING
POSSESSION OF THIS DOCUMENT, THE RECIPIENT ACKNOWLEDGES AND AGREES THAT THIS DOCUMENT CANNOT BE USED IN ANY
MANNER ADVERSE TO THE INTERESTS OF EATON AND THAT NO PORTION OF THIS DOCUMENT MAY BE COPIED OR OTHERWISE
REPRODUCED WITHOUT THE PRIOR WRITTEN CONSENT OF EATON. IN THE CASE OF CONFLICTING CONTRACTUAL PROVISIONS, THIS
NOTICE SHALL GOVERN THE STATUS OF THIS DOCUMENT.
NOTICE TO PERSONS RECEIVING THIS DOCUMENT AND/OR TECHNICAL INFORMATION
C Eaton Corporation, All Rights Reserved
A
DSD_AFM_PORT_ACAD_CUSTOMER.DWG
A
2014 211=6
INCHES
00198-1083
2014/06/27M. EganBR 1" LOADCENTER, MAIN LUG ONLY, INDOOR NEMA 1, 120/240 VAC, 1 PHASE
TYPE BR LOADCENTER RATINGS:
Enclosure: Indoor NEMA 1
Incoming Main: Main Lug Only
Loadcenter Electrical Rating: 120/240 VAC, Single Phase
Bus Bar Ampere: 125 Amps Max
Number of Spaces & Circuits: See Table on Page 2
Incoming Wire Range: #6-2/0
Bus Bar Material: Tin Plated Aluminum (Standard)
Trim Type: Combination (Standard)
Trim Paint: ANSI 61 Light Gray
Short Circuit Rating: See Branch Breaker Ratings
Box Dimensions: 14.3"W x 3.9"D x "A" (See Table on page 2)
FEATURES:
Steel Backpan - For reliable breaker mounting.
Single keyhole mounting - One keyhole at top
and bottom for mounting and leveling.
Split Neutral Bar Assembly - For better
management of load wires.
Drywall marking on Enclosure - Indicates
mounting depth for flush applications
Top or bottom feed - Acceptable for either top or
or bottom applications.
Warranty - 10 year limited warranty on all
BR Loadcenters and Breakers.
OPTIONAL ACCESSORIES:
Catalog Number Description
GBK5 5 POS #14-4 Ground Bar
GBK10 10 POS #14-4 Ground Bar
GBK14 14 POS #14-4 Ground Bar
GBK21 21 POS #14-4 Ground Bar
NL20 Neutral/Ground Lug #2/0 max
BRFP 1" Filler Plate
BREQS125 Hold-down kit for Type BR breaker
BR230SUR BR 2P 30A Circuit Breaker w/ Surge Protection
Ref: 96-3549
14.3 3.9
"A"
Page: 1 of 2
GO/NEG-Alt-Date: Job Name:
Item Number: Catalog Number: Designation:
SY880507X4K1-0003-12/17/2014 STONE QUARRY
BR1616L125 AP1
4 123
B
C
D
A
B
C
D
3 2
TITLE
SHEET
DRAFTER/DESIGNER DATE (YYYY/MM/DD)
DRAWING
NUMBER
REVISIONSIZEEATON CORPORATION - CONFIDENTIAL AND PROPRIETARY
UNLESS OTHERWISE SPECIFIED
DIMENSIONS IN
SCALE
OF
THIS DOCUMENT, INCLUDING THE DRAWING AND INFORMATION CONTAINED THEREON, IS CONFIDENTIAL AND IS THE EXCLUSIVE
PROPERTY OF EATON CORPORATION, AND IS MERELY ON LOAN AND SUBJECT TO RECALL BY EATON AT ANY TIME. BY TAKING
POSSESSION OF THIS DOCUMENT, THE RECIPIENT ACKNOWLEDGES AND AGREES THAT THIS DOCUMENT CANNOT BE USED IN ANY
MANNER ADVERSE TO THE INTERESTS OF EATON AND THAT NO PORTION OF THIS DOCUMENT MAY BE COPIED OR OTHERWISE
REPRODUCED WITHOUT THE PRIOR WRITTEN CONSENT OF EATON. IN THE CASE OF CONFLICTING CONTRACTUAL PROVISIONS, THIS
NOTICE SHALL GOVERN THE STATUS OF THIS DOCUMENT.
NOTICE TO PERSONS RECEIVING THIS DOCUMENT AND/OR TECHNICAL INFORMATION
C Eaton Corporation, All Rights Reserved
A
DSD_AFM_PORT_ACAD_CUSTOMER.DWG
A
2014 221=1
INCHES
00198-1083
2014/06/27M. EganBR 1" LOADCENTER, MAIN LUG ONLY, INDOOR NEMA 1, 120/240 VAC, 1 PHASE
LOADCENTER DETAILS
Catalog #Dim "A"Main Lug
Amps
Spaces /
Circuits
Bus
Material
Wire Size
Range Cu/Al
60°C or 75°C
Notes
BR1212L125 16.75 125 12/12 Alum.#6-2/0
BR1224L125 16.75 125 12/24 Alum.#6-2/0
BR1224L125DG 16.75 125 12/24 Alum.#6-2/0 5 ground terminals included plus 2/0 lug
BR1224L125G 16.75 125 12/24 Alum.#6-2/0 8 ground terminals included
BR1224L125P 16.75 125 12/24 Alum.#6-2/0
BR1616L125 18.75 125 16/16 Alum.#6-2/0
BR1624L125 18.75 125 16/24 Alum.#6-2/0
BR1624L125G 18.75 125 16/24 Alum.#6-2/0 10 ground terminals included plus 2/0 lug
BR1624L125GBP 18.75 125 16/24 Alum.#6-2/0 10 ground terminals included plus 2/0 lug
BR2020L125 21 125 20/20 Alum.#6-2/0
BR2024L125 21 125 20/24 Alum.#6-2/0
BR2024L125G 21 125 20/24 Alum.#6-2/0 12 ground terminals included plus 2/0 lug
BR2024L125P 21 125 20/24 Alum.#6-2/0
BR2424L125 23 125 24/24 Alum.#6-2/0
BR2424L125B 23 125 24/24 Alum.#6-2/0
BR2424L125G 23 125 24/24 Alum.#6-2/0 12 ground terminals included plus 2/0 lug
BR2424L125GBP 23 125 24/24 Alum.#6-2/0 12 ground terminals included plus 2/0 lug
BR2430L125G 23 125 24/30 Alum.#6-2/0 14 ground terminals included plus 2/0 lug
BR3042L125 29 125 30/42 Alum.#6-2/0
Note: Catalog Numbers may have addtional characters at the end which describe alternate details, including but not limited to
the following: S, F, W, G, GK, PK, PB, SF, RN, MI, V and #s. Contact sales for those specific details when necessary.
Page: 2 of 2
GO/NEG-Alt-Date: Job Name:
Item Number: Catalog Number: Designation:
SY880507X4K1-0003-12/17/2014 STONE QUARRY
BR1616L125 AP1
4 123
B
C
D
A
B
C
D
3 2
TITLE
SHEET
DRAFTER/DESIGNER DATE (YYYY/MM/DD)
DRAWING
NUMBER
REVISIONSIZEEATON CORPORATION - CONFIDENTIAL AND PROPRIETARY
UNLESS OTHERWISE SPECIFIED
DIMENSIONS IN
SCALE
OF
THIS DOCUMENT, INCLUDING THE DRAWING AND INFORMATION CONTAINED THEREON, IS CONFIDENTIAL AND IS THE EXCLUSIVE
PROPERTY OF EATON CORPORATION, AND IS MERELY ON LOAN AND SUBJECT TO RECALL BY EATON AT ANY TIME. BY TAKING
POSSESSION OF THIS DOCUMENT, THE RECIPIENT ACKNOWLEDGES AND AGREES THAT THIS DOCUMENT CANNOT BE USED IN ANY
MANNER ADVERSE TO THE INTERESTS OF EATON AND THAT NO PORTION OF THIS DOCUMENT MAY BE COPIED OR OTHERWISE
REPRODUCED WITHOUT THE PRIOR WRITTEN CONSENT OF EATON. IN THE CASE OF CONFLICTING CONTRACTUAL PROVISIONS, THIS
NOTICE SHALL GOVERN THE STATUS OF THIS DOCUMENT.
NOTICE TO PERSONS RECEIVING THIS DOCUMENT AND/OR TECHNICAL INFORMATION
C Eaton Corporation, All Rights Reserved
A
DSD_AFM_PORT_ACAD_CUSTOMER.DWG
A
2014 211=6
INCHES
00198-1083
2014/06/27M. EganBR 1" LOADCENTER, MAIN LUG ONLY, INDOOR NEMA 1, 120/240 VAC, 1 PHASE
TYPE BR LOADCENTER RATINGS:
Enclosure: Indoor NEMA 1
Incoming Main: Main Lug Only
Loadcenter Electrical Rating: 120/240 VAC, Single Phase
Bus Bar Ampere: 125 Amps Max
Number of Spaces & Circuits: See Table on Page 2
Incoming Wire Range: #6-2/0
Bus Bar Material: Tin Plated Aluminum (Standard)
Trim Type: Combination (Standard)
Trim Paint: ANSI 61 Light Gray
Short Circuit Rating: See Branch Breaker Ratings
Box Dimensions: 14.3"W x 3.9"D x "A" (See Table on page 2)
FEATURES:
Steel Backpan - For reliable breaker mounting.
Single keyhole mounting - One keyhole at top
and bottom for mounting and leveling.
Split Neutral Bar Assembly - For better
management of load wires.
Drywall marking on Enclosure - Indicates
mounting depth for flush applications
Top or bottom feed - Acceptable for either top or
or bottom applications.
Warranty - 10 year limited warranty on all
BR Loadcenters and Breakers.
OPTIONAL ACCESSORIES:
Catalog Number Description
GBK5 5 POS #14-4 Ground Bar
GBK10 10 POS #14-4 Ground Bar
GBK14 14 POS #14-4 Ground Bar
GBK21 21 POS #14-4 Ground Bar
NL20 Neutral/Ground Lug #2/0 max
BRFP 1" Filler Plate
BREQS125 Hold-down kit for Type BR breaker
BR230SUR BR 2P 30A Circuit Breaker w/ Surge Protection
Ref: 96-3549
14.3 3.9
"A"
Page: 1 of 2
GO/NEG-Alt-Date: Job Name:
Item Number: Catalog Number: Designation:
SY880507X4K1-0003-12/17/2014 STONE QUARRY
BR1616L125 AP2
4 123
B
C
D
A
B
C
D
3 2
TITLE
SHEET
DRAFTER/DESIGNER DATE (YYYY/MM/DD)
DRAWING
NUMBER
REVISIONSIZEEATON CORPORATION - CONFIDENTIAL AND PROPRIETARY
UNLESS OTHERWISE SPECIFIED
DIMENSIONS IN
SCALE
OF
THIS DOCUMENT, INCLUDING THE DRAWING AND INFORMATION CONTAINED THEREON, IS CONFIDENTIAL AND IS THE EXCLUSIVE
PROPERTY OF EATON CORPORATION, AND IS MERELY ON LOAN AND SUBJECT TO RECALL BY EATON AT ANY TIME. BY TAKING
POSSESSION OF THIS DOCUMENT, THE RECIPIENT ACKNOWLEDGES AND AGREES THAT THIS DOCUMENT CANNOT BE USED IN ANY
MANNER ADVERSE TO THE INTERESTS OF EATON AND THAT NO PORTION OF THIS DOCUMENT MAY BE COPIED OR OTHERWISE
REPRODUCED WITHOUT THE PRIOR WRITTEN CONSENT OF EATON. IN THE CASE OF CONFLICTING CONTRACTUAL PROVISIONS, THIS
NOTICE SHALL GOVERN THE STATUS OF THIS DOCUMENT.
NOTICE TO PERSONS RECEIVING THIS DOCUMENT AND/OR TECHNICAL INFORMATION
C Eaton Corporation, All Rights Reserved
A
DSD_AFM_PORT_ACAD_CUSTOMER.DWG
A
2014 221=1
INCHES
00198-1083
2014/06/27M. EganBR 1" LOADCENTER, MAIN LUG ONLY, INDOOR NEMA 1, 120/240 VAC, 1 PHASE
LOADCENTER DETAILS
Catalog #Dim "A"Main Lug
Amps
Spaces /
Circuits
Bus
Material
Wire Size
Range Cu/Al
60°C or 75°C
Notes
BR1212L125 16.75 125 12/12 Alum.#6-2/0
BR1224L125 16.75 125 12/24 Alum.#6-2/0
BR1224L125DG 16.75 125 12/24 Alum.#6-2/0 5 ground terminals included plus 2/0 lug
BR1224L125G 16.75 125 12/24 Alum.#6-2/0 8 ground terminals included
BR1224L125P 16.75 125 12/24 Alum.#6-2/0
BR1616L125 18.75 125 16/16 Alum.#6-2/0
BR1624L125 18.75 125 16/24 Alum.#6-2/0
BR1624L125G 18.75 125 16/24 Alum.#6-2/0 10 ground terminals included plus 2/0 lug
BR1624L125GBP 18.75 125 16/24 Alum.#6-2/0 10 ground terminals included plus 2/0 lug
BR2020L125 21 125 20/20 Alum.#6-2/0
BR2024L125 21 125 20/24 Alum.#6-2/0
BR2024L125G 21 125 20/24 Alum.#6-2/0 12 ground terminals included plus 2/0 lug
BR2024L125P 21 125 20/24 Alum.#6-2/0
BR2424L125 23 125 24/24 Alum.#6-2/0
BR2424L125B 23 125 24/24 Alum.#6-2/0
BR2424L125G 23 125 24/24 Alum.#6-2/0 12 ground terminals included plus 2/0 lug
BR2424L125GBP 23 125 24/24 Alum.#6-2/0 12 ground terminals included plus 2/0 lug
BR2430L125G 23 125 24/30 Alum.#6-2/0 14 ground terminals included plus 2/0 lug
BR3042L125 29 125 30/42 Alum.#6-2/0
Note: Catalog Numbers may have addtional characters at the end which describe alternate details, including but not limited to
the following: S, F, W, G, GK, PK, PB, SF, RN, MI, V and #s. Contact sales for those specific details when necessary.
Page: 2 of 2
GO/NEG-Alt-Date: Job Name:
Item Number: Catalog Number: Designation:
SY880507X4K1-0003-12/17/2014 STONE QUARRY
BR1616L125 AP2
V1-T1-42 Volume 1—Residential and Light Commercial CA08100002E—September 2014 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.2 Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers
Overview
Product Selection Guide
BR Loadcenters
Description
Service
Single-phase, three-wire, 120/240 Vac Three-phase, four-wire, 208Y/120 Vac
Three-phase, three-wire, 240 Vac delta
Short-Circuit Current Rating
10 kAIC: All single- and three-phase loadcenters 70–225 A, 8 to 42 circuits
22 kAIC: All convertible loadcenters using 125 A rated Type BRH main breakers or
selected factory installed 125 A rated Type BRH main breaker
25 kAIC: All convertible and factory-installed single-phase loadcenters rated
150 and 200 A using Type CSR main breakers
Main Breaker/Main Lug Loadcenters
Single-phase
Main breaker: 100, 125, 150, 200, 225, 400, 600 A
Main lugs: 70, 125, 150, 200, 225, 400, 600 A
Three-phase
Main breaker: 100, 125, 150, 200, 225, 400, 600 A
Main lugs: 100, 125, 150, 200, 225, 400, 600 A
Convertible Loadcenters
Main breaker: single-phase up to 200 A and three-phase up to 225 A Main lugs: single-phase up to 200 A and three-phase up to 150 A
Branch Breakers
Types BR, BRH and BRHH: 10–150 A. single-, two- and three-pole; selected amperage
available in switching duty, HACR, shunt trip and high magnetic setting
Type GFCB: 15–60 A
Types BJ and BJH: 125–225 A; two- and three-pole
Type BD Twin: 10–50 A; two of one-pole; take one 1-inch (25.4 mm) space
Type BQ and BQC Multibreaker: 15–30 A. Two of two-pole or one two-pole and
two one-pole; takes two 1-inch (25.4 mm) spaces
Type BRW: 15–30 A; two-pole water heater breakers
Type BRSN: 15–30 A; two-pole switching neutral breakers
Type BR 15–100 A; two-pole, 240 Vac delta breakers
BR-AFCI arc fault circuit interrupter
Enclosures
NEMA Type 1 indoor
NEMA Type 3R outdoor
NEMA 4X
Meets or exceeds UL requirements for indoor or outdoor applications
Loadcenter and Breaker Accessories
Branch circuit breaker:
Auxiliary components Hold-down kits Handle ties
Lockoffs Lockdogs
Complete line of ground bar kits 5, 10, 14 and 21 circuit, some with additional #2/0 lugs;
each terminal will accommodate: (3) #14–#10 Cu/Al or (1) #14–#4 Cu/Al
Main and sub-feed lugs 125, 150, 225 A—two- and three-pole
Shunt trips
Surge protection:
Single-phase plug-on surge protector Single-phase bottle type surge protector
Three-phase bottle type surge protector Single-phase whole home surge protector
Universal rainproof conduit hubs
Group One: 3/4, 1, 1-1/4, 1-1/2, 2 inches (19.1, 25.4, 31.8, 38.1, 50.8 mm)
Group Two: 2, 2-1/2, 3 inches (50.8, 63.5, 76.2 mm)
Adapter plate
Bussing
Tin-plated aluminum as standard Limited copper bus panels available
Volume 1—Residential and Light Commercial CA08100002E—September 2014 www.eaton.com V1-T1-43
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.2Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers
Product Description
Loadcenters are enclosures
specifically designed to house
the branch circuit breakers
and wiring required to
distribute power to individual
circuits. They contain either a
main breaker when used at
the service entrance point or
a main lug when used as a
sub-panel to add circuits to
existing service. The main
breaker protects the main
entire panel and can be used
as a service disconnect. The
branch breakers protect the
wires leading to individual
electrical loads such as
fixtures and outlets.
Features, Benefits and
Functions
Loadcenter Construction
Eaton’s Type BR loadcenters
have standard tin-plated
aluminum bus with a limited
availability of copper bus.
The sum of the handle
ratings connected to any stab
is limited to 150 A maximum
on the 100 and 125 A
loadcenters, and 200 A on
loadcenters with 150 A or
higher main bus. NEMA
Type 1 boxes or enclosures
are manufactured from
galvanized steel. Raintight
boxes are manufactured
from galvanized steel, then
finished using an electrostatic
powder coat, baked urethane
paint process.
Neutrals
Eaton Type CH loadcenters
feature two types of neutrals:
Insulated/Bondable Split
Neutral
Panels are supplied with split
insulated neutrals with an
insulated cross strap. For
service entrance applications,
the neutral must be bonded
by using the bonding strap
supplied with the panel. For
non-service entrance (sub-
panel) applications, the panel
may be installed with the
bonding strap not connected
to the neutral. Separate
ground bars must be used on
non-service entrance panels.
Insulated/Bondable Single
Neutral
Panels are supplied with a
single insulated neutral. For
service entrance applications,
all that is required to bond the
neutral is to loosen the
bonding screw and the
neutral screw directly beside
it, insert the bonding strap
into the neutral bar, and re-
tighten both connections. The
single neutral can be moved
by the contractor to the other
side of the panel, if desired.
When used as a service
entrance panel, unused
neutral connections may be
used for the termination of
equipment grounds. For non-
service entrance (sub-panel)
applications, the panel may
be installed with the bonding
strap not connected to the
neutral. Separate ground bars
must be used on non-service
entrance panels.
Grounds
In service entrance
applications where the
neutral is bonded, unused
neutral holes may be used
for terminating ground
conductors. In sub-feed
panels, the neutral must be
isolated (non-bonded), and
ground wires must be
terminated on a separate
ground bar.
The insulated/bondable
single/split neutral panels
have sufficient terminations
for both ground and neutral
conductors. The insulated/
bondable single split neutral
panels are supplied with a
separate factory-installed
ground bar if the catalog
number contains a “G.” If
not, a separate ground bar
should be installed. Insulated/
Bondable Single Neutral
panels are supplied without
a ground bar (unless
otherwise noted), and ground
bar kits if needed must be
purchased separately.
Neutral and Ground Terminals
The standard terminals on
grounds and neutrals are
rated to accept (3) #14–#10
Cu/Al or (1) #14–4, provided
the cables terminated are of
the same material. For larger
cables, add-on neutral lugs
may be ordered from the
accessories on Page
V1-T1-65.
Note: NEC allows only one
current-carrying conductor
per hole on neutrals unless
otherwise noted.
Bottom Fed Loadcenters
For single-phase 225 A and
below loadcenters that are
bottom fed, a standard panel
can be rotated 180 degrees
to allow straight-in wiring of
power cables to the main
terminals. Because the main
circuit breaker handle
operates horizontally, the
orientation of the main circuit
breaker handle is consistent
with the requirements of NEC
2008 Article 240.81.
Gutter Splicing
Loadcenters are not UL listed
as wiring troughs. Therefore,
gutter splicing of riser cables
to tap off to the main device
is not permitted. Refer to
NEC 2008 Article 312.8.
Fire Rating
Due to the numerous
openings in both loadcenter
boxes and trims, they should
not be mounted in firewalls.
There is no approved method
for sealing the enclosures for
this application.
Date Code
The date of manufacture of
each loadcenter is printed on
the outside of the carton as
well as inside the loadcenter.
On the carton, the date code
is printed on the end carton
label. In the loadcenter, the
date code is located on the
small white label located on
the right side wall (with the
main device on top).
The date code is in the
following format: F # # # &.
The “F” is the numeric
code for the Lincoln, IL
plant, and the three numbers
are the year and week of
manufacturing, e.g., 023. The
“!” sign at the end signifies
the decade of the 2010.
Therefore, the date code
F023& would indicate
that the product was
manufactured in the 23rd
week of 2010. The 1980s
are represented by the “+”
sign and the 1990s are
represented by a “=”
at the end of the code.
Surge Protectors
Complete home surge
protection is available in
multiple options, including
a factory-installed option that
provides the highest level of
surge protection in a
residential design. See Tab 3
for more details.
Circuit Breaker Case
Interrupting Capacity
●10 kAIC
●22 kAIC
●25 kAIC
Warranty Information
●10-year limited
loadcenter warranty
●10-year limited branch
breaker warranty
V1-T1-44 Volume 1—Residential and Light Commercial CA08100002E—September 2014 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.2 Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers
Type BR Loadcenter
Warranty
10-year warranty on all
Type BR loadcenters and
circuit breakers.
Single Keyhole Mounting
One keyhole at the top
and bottom provides easier
mounting and leveling
Neutral Bus (Strap)
Is easily removable for
sub-panel applications
Bonding Z-Strap
Provides easy field
conversion for service
entrance applications
Twin Neutral Bars
Minimum 150% neutral
capacity
Steel Backpan
Provides solid and reliable
breaker mounting—single
piece design for stability and
durability
Extra 1.5 inch Knockout
(38.1 mm)
Larger knockout provides
easier installation and time
savings
“Tangential” Center Knockout
Easier installation for conduit
applications
Commercial Grade Main
Breaker
25 kAIC series rated main
breaker for superior protection
2/0 Lug
Easily removable and can be
installed in any location
on the neutral bar
Drywall Marking on Enclosure
Indicates proper mounting
depth for flush applications
Standard Tin-Plated
Aluminum Bus
Excellent conductivity and
corrosion resistance
Copper bus options
available for select
catalog numbers
Type BR AFCI Breakers
Compact design for easier
wiring and improved
wireway access
Optional LED indicates
one of six trip codes for
circuit diagnostics
Provides a clean gutter space
Top or Bottom Feed
Straight-in wiring saves labor
and material
One panel for either top or
bottom applications
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
Volume 1—Residential and Light Commercial CA08100002E—September 2014 www.eaton.com V1-T1-45
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.2Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers
Standards and Certifications
UL Listings
All Eaton Type BR loadcenters
are listed under UL File
E52977 except the
2–8 circuit loadcenters,
up through and including
125 A, which are listed under
UL File E8741.
Catalog Number Selection
Single- and Three-Phase Through 600 A
Note
1 No character space used.
3 BR 30 42 B C 200
Phase
Blank = Single-phase
1
3 = Three-phase
Construction
Blank = No feed thru lugs
1
F = Feed-through lugs
G = Ground bar
P = Current design
NY = NY City gutter space
Number of 1-Inch
(25.4 mm) Spaces
Factory Options
SUR = Factory integrated surge
Eaton’s Type BR
Loadcenter
Maximum Number
of Circuits
Bus
Blank = Aluminum bus
1
C = Copper bus
Main Device
B = Main breaker
L = Main lug
N = Convertible main
H = Main breaker high AIC
Enclosure
R = NEMA Type 3R rainproof
S = NEMA Type 1 indoor with
surface trim
F = NEMA Type 1 indoor with
flush trim
Blank = NEMA Type 1 indoor with
combination trim 1
RIS = Riser panel
Amperes
50 = 50 A
70 = 70 A
100 = 100 A
125 = 125 A
150 = 150 A
200 = 200 A
225 = 225 A
300 = 300 A
400 = 400 A
600 = 600 A
V1-T1-70 Volume 1—Residential and Light Commercial CA08100002E—September 2014 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.2 Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers
Technical Data and Specifications
General
A. The Contractor shall
furnish and install
deadfront loadcenters
incorporating circuit
breakers of the number,
rating and type as
specified herein and
as shown on the
contract drawings.
B. The loadcenter and all
components shall be
designed, manufactured
and tested in accordance
with the latest applicable
standards of UL, NEMA
and NEC including:
1. UL 67—Standards
for Panelboards.
C. UL 50—Standards for
Cabinets and Boxes.
D. UL 489—Standards for
Molded Case Circuit
Breakers.
E. UL 869—Standards for
Service Equipment.
F. Federal Specification
W-C 375B—Circuit
Breakers.
G. Federal Specification
W-C P115b—Panel
Power Distribution
Type 1, Class 2.
Qualifications
A. The manufacturer of the
loadcenter shall be the
manufacturer of the
circuit breaker within
the loadcenter.
B. For the equipment
specified herein, the
manufacturer shall be
ISO 9000 certified.
C. The manufacturer of
this equipment shall have
produced similar
electrical equipment
for a minimum period
of seven (7) years.
Manufacturers
A. Eaton.
Ratings
A. Loadcenters shall be
rated for 120/240 Vac and
shall have short-circuit
ratings as shown on the
drawings or
as herein scheduled,
but not less than
10,000 amperes rms
symmetrical.
B. Circuit breakers shall be a
minimum of 125 A
frame. Circuit breakers
15 through 125 A trip size
shall take up the same
pole spacing.
C. Loadcenters shall be
labeled with a UL short-
circuit rating. When
series combination
ratings are applied
with integral or remote
upstream devices, a label
shall be provided. Series
combination ratings shall
cover all trip ratings of
installed frames. It shall
state the conditions of
the UL series ratings
including:
1. Size and type of
upstream device.
2. Branch devices that can
be used.
3. UL series short
circuit rating.
Construction
A. All interiors, with the
exception of the branch
circuit breakers, shall
be completely factory
assembled with main
breakers, main lugs,
or no main device.
B. Interiors shall be
designed so that circuit
breakers can be replaced
without disturbing
adjacent units and
without removing the
main bus connectors and
shall be designed so that
circuits may be changed
without machining,
drilling, or tapping.
C. Physical means shall be
provided to prevent the
installation of more
overcurrent devices than
that number for which
the enclosure was
designed, rated and
approved. Half-size
breakers shall have a
UL listed rejection tab
over the line terminals.
Loadcenter interiors
must have notched stabs
to accept these rejection
tab class CTL breakers, if
required and approved.
Bus
A. Busbars for the main and
cross connectors shall be
[tin-plated aluminum]
[copper] in accordance
with Underwriters
Laboratories standards.
Busing shall be braced
throughout to conform to
industry standard practice
governing short-circuit
stresses in loadcenters.
Note: Note to spec writer—
select one (copper available
in limited ratings).
B. Neutral busing shall
have a suitable lug for
each outgoing feeder
requiring a neutral
connection of same
ampacity as branch.
Wiring/Termination
A. All wire connectors and
terminals shall be of the
anti-turn solderless type
and shall be suitable for
copper or aluminum wire
of the sizes indicated. All
connectors must meet
the “Requirements for
Wire Connectors and
Soldering Lugs” as
stated in UL 486B.
B. All loadcenters where
marked shall be suitable
for use with 60 °C or
75 °C rated wire.
Circuit Breakers
A. Circuit breakers shall
be molded case type.
Circuit breakers shall
have four-rivet
construction (GFI Type—
5 rivets). Multipole circuit
breakers shall be of a
stack pole design to
provide electrical
phase isolation.
B. Each pole of the
circuit breaker will
provide inverse time
delay overload and
instantaneous short-
circuit protection by
means of both thermal
and magnetic sensors.
C. The circuit breaker
calibration shall
not be affected by
environmental changes
in relative humidity.
The thermal bimetal
element shall be welded
to the steel frame and
calibration shall be set
independent of the
molded case by computer
controlled equipment.
D. All circuit breakers
shall be operated by
a toggle-type handle
and multipole circuit
breakers shall have an
internal common trip
mechanism. The
circuit breakers shall
incorporate trip
mechanisms that are
mechanically trip-free
from the handle. The
handle position shall
provide visual trip
indication.
E. Contacts shall be of
non-welding silver alloy.
F. All circuit breakers shall
have the trip rating
inscribed on the handle
on each circuit breaker
pole. Also, unique color-
coded cases that indicate
the UL listed 10 kA or
22 kA interrupting
ratings. Breakers shall
be able to be used
as main or branch
disconnect devices.
Volume 1—Residential and Light Commercial CA08100002E—September 2014 www.eaton.com V1-T1-71
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.2Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers
G. Branch circuit breakers
may also be used in
the 1/2-inch (12.7 mm)
per pole ratings that
include two-pole 1-inch
(25.4 mm) wide modules
and four-pole 2-inch
(50.8 mm) wide
modules. Two-pole circuit
breakers must
incorporate a common
trip mechanism. The
exclusive CTL rejection
tab feature shall be
provided to limit the
number of branch
devices for a loadcenter
to 42, in compliance with
NEC Article 384.15.
H. Circuit breakers shall
be completely enclosed
in a molded case of
thermoset material.
No internal aluminum
parts shall be used. All
internal ferrous parts
shall be plated to
prevent corrosion.
I. All terminals shall be
listed for use with copper
or aluminum conductors.
Terminals shall be of the
box lug or clamp type
design. The terminals
shall meet UL 486B
requirements and shall
be suitable for use with
either 60 °C or
75 °C wire.
J. The calibrated bimetal
assembly shall be
mechanically isolated
from the load terminal
using a flexible braided
copper shunt wire, such
that movement of the
terminals due to twisting
and overtorquing does
not affect breaker
calibration.
K. Breakers shall be SWD
rated and/or HACR rated
as required.
L. Arc Fault Interrupting
circuit breakers, (AFI),
shall be provided on all
15 and 20 A single-phase
120/240 Vac circuits
except those indicated as
remote controlled
breakers. AFI breakers
shall be “Classified for
mitigating the effects of
arcing faults,” or
conforming to UL
Standard 1699 and as
defined by Article 210.12
Section A of the 1999
NEC Code.
Surge Protection Devices
See Volume 1, Tab 2 for
complete details on
surge protection.
Enclosures
A. Loadcenter shall have
NEMA Type 1 general
purpose or NEMA Type
3R rainproof enclosures
as indicated on the
drawings and shall be
surface or combination
flush/surface mounted
except where noted.
B. Boxes shall be made
from galvanized sheet
steel having multiple
knockouts. Rainproof
boxes shall use
galvanized steel or
an approved coating
system which meets or
exceeds standards for
outdoor NEMA Type 3R
enclosures. Boxes shall
be of sufficient size to
provide at least a
minimum code gutter
space on all sides.
C. The deadfront shall
have an easy adjustment
feature for flush
applications.
D. Boxes shall be factory
assembled into a single
rigid structure.
E. Unless otherwise noted
on drawings, hinged
doors covering all circuit
breaker handles shall
be included in all trims.
Trim doors shall not
uncover any live parts
in making the circuit
breaker handles
accessible. If key locks
are required, all locks
shall be keyed alike.
F. Combination trims for
flush and surface panels
shall be flat and shall
overlap the box by at
least 5/8-inch (15.9 mm)
all around. Trims shall
be mounted by a
screwdriver without the
need for special tools.
Finish
A. Trims shall be bonderized
and finished with a light
gray ANSI-61 enamel.
The paint finish shall be
of a type to which field
applied paint will adhere.
Factory Testing
A. The standard factory
tests shall be performed
on the equipment
provided under this
section. All tests shall
be in accordance with
the latest version of UL
and NEMA.
Volume 1—Residential and Light Commercial CA08100002E—September 2014 www.eaton.com V1-T1-49
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.2Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers
Single-Phase—Main Lug Loadcenters
Single-Phase Three-Wire—120/240 Vac—Insulated/Bondable Split Neutral, continued
Notes
1 Ground bar kits priced separately unless otherwise noted. See Page V1-T1-65.
2 Has notch for BREQS125 hold-down kit.
3 Single, movable neutral is provided.
4 Combination cover style.
5 Suitable for use as service equipment when not more than six main disconnecting means are provided and when not used as a lighting and appliance panelboard
(see Article 408.34 of the NEC).
6 Ground bars GBK5 and GBK520 installed.
7 Rainproof panels are furnished with hub closure plates. For rainproof hubs, refer to Page V1-T1-65.
8 Ground bar GBK1220 installed.
9 Has notch for BRHDK125 hold-down kit.
j Includes through-feed lugs for both phase and neutral conductors.
Main
Ampere Rating
Maximum Number
1-Inch (25.4 mm)Enclosure
Type
Box
Size
Wire Size Range
Cu/Al 60 °C or 75 °C
for Main Lugs
Loadcenter Catalog Number
with Combination or
NEMA Type 3R Cover 1Spaces Circuits
125 12 12 Indoor B1 #6–2/0 BR1212L125 2345
12 24 Indoor B1 BR1224L125 245
12 24 Indoor B1 BR1224L125G 245
12 24 Indoor B1 BR1224L125DG 2456
12 24 Outdoor B1R BR1224L125R 257
16 16 Indoor B2 BR1616L125 245
16 24 Indoor B2 BR1624L125 24
16 24 Indoor B2 BR1624L125G 24
16 24 Outdoor B2R BR1624L125R 27
20 20 Indoor C1 BR2020L125 245
20 24 Indoor C1 BR2024L125 24
20 24 Indoor C1 BR2024L125G 248
20 24 Outdoor C1R BR2024L125R 27
24 24 Indoor C2 BR2424L125 24
24 24 Indoor C2 BR2424L125G 248
30 42 Indoor D1 BR3042L125 24
150 16 30 Indoor C2 #1–300 kcmil BR1630L150 49
20 30 Indoor C2 BR2030L150 49
200 8 16 Outdoor B2R #1–300 kcmil BR816L200RF 57j
12 24 Indoor B2 BR1224L200 459
12 24 Outdoor B2R BR1224L200R 579
20 40 Indoor C2 BR2040L200 49
20 40 Indoor C2 BR2040L200G 489
20 40 Outdoor C3R BR2040L200R 79
24 40 Indoor C4 BR2440L200 49
30 40 Indoor D1 BR3040L200 49
30 40 Indoor D1 BR3040L200G 489
30 40 Outdoor D1R BR3040L200R 79
40 40 Indoor G1 BR4040L200 49
40 40 Indoor G1 BR4040L200G 49
40 40 Outdoor G1R BR4040L200R 79
225 42 42 Indoor L1 #1–300 kcmil BR4242L225 4
42 42 Outdoor L1R BR4242L225R 7
BR1224L125
BR1224L200
Volume 1—Residential and Light Commercial CA08100002E—September 2011 www.eaton.com V1-T1-27
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.1Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers
Field Installation Rainproof Conduit Hubs
Ground Bar Kits
Ground Bar Legend
Grounded “B” Phase Adapters Neutral Bar Accessories
Notes
1 Must be purchased in multiples of ordering quantities indicated.
2 Distance between mounting holes is 1-3/4 inches (44.5 mm).
3 For single- and three-phase 400A loadcenters.
4 Distance between mounting holes is 2-13/32 inches.
5 Cannot be used in Safety Breaker Panels. Classic Plus Panels only.
Description
Conduit Size Ordering
Quantity 1
Catalog
NumberInches (mm)
Group 1—for use with 70, 100 and 125A MLO and MCB loadcenters and circuit breaker enclosures,
and the following 150 and 200A panels: CH8B150RF, CH8B200RF
0.75 (19.1) 1 DS075H1
1.00 (25.4) 1 DS100H1
1.25 (31.8) 1 DS125H1
1.50 (38.1) 1 DS150H1
2.00 (50.8) 1 DS200H1
Group 2—for use with 150, 200 and 225A MLO and MCB loadcenters and circuit breaker enclosure
except for the following 150 and 200A panels: CH8B150RF, CH8B200RF
2.00 (50.8) 1 DS200H2
2.50 (63.5) 1 DS250H2
3.00 (76.2) 1 DS300H2
Adapter kit—allows Installing a Group 1 hub on devices arranged for Group 2 hubs — 1 DS900AP
Group 1—small blank hub closure plate — 1 DS900CP1
Group 2 —þlarge blank hub closure plate — 1 DS900CP2
Description (See Legend)
Length Ordering
Quantity 2
Catalog
NumberInches (mm)
dssssds
dssssdsj
dssssdssssss
dssssdssssssj
dssssdssssssssss
dssssdssssssssssj
dssssdsssssssssssssssss
dssssdsssssssssssssssssj
ssssssssdssssssdsssssss
2.54 (64.5) 1 GBK5 2
3.59 (91.2)1 GBK520 2
4.29 (109.0)1 GBK10 2
5.34 (135.6)1 GBK1020 2
4.61 (117.1)1 GBK13 2
5.69 (144.5)1 GBK14 2
6.74 (171.2)1 GBK1420 2
8.14 (206.8)1 GBK21 2
9.19 (233.4)1 GBK2120 2
7.94 (201.7)1 CH9GP21 34
DS100H1
GBK14
fdfffkfdfkfffkfs
j
d
= (3) #14–#10 Cu/Al or (1) #14–#4 Cu/Al
= (1) #6–2/0 Cu/Al
= (1) 1/0–14 or (3) #10–12 Cu/Al
= (1) #14–1/0 Cu/Al or (3) #14–#10 Cu/Al
= Mounting holef kMaximum
Amperes
Three-Phase Loadcenter
Types of Panels
Kit Catalog
Number 5
125 12–32 circuit main lug CHGRD1
225 Main lug and CHH main breaker panels CHGRD2
CC main CB panels CHGRD3
Description
Catalog
Number 5
Split neutral kit for 22 circuit 125A maximum CHSN125C
Split neutral kit for 32 circuit 200A maximum CHSN225J
Split neutral kit for 42 circuit 200A maximum CHSN225K
Replacement neutral for all C type boxes CHN125C
Replacement neutral for all D type boxes CHN125D
Replacement neutral for all L type boxes CHN225L
Isolated Neutral Assembly (computer circuits)BINA
V1-T1-76 Volume 1—Residential and Light Commercial CA08100002E—September 2014 www.eaton.com
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.2 Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers
Product Selection
Plug-On Circuit Breakers, Types BR—10/22/42 kAIC, 120 Vac, 120/240 Vac and 240 Vac
Type BR Breakers, 1-Inch (25.4 mm) per Pole 120/240, 10, 22 and 42 kAIC
Notes
1 One pole, 1-inch (25.4 mm) per pole circuit breakers are available with high magnetic setting for switching large tungsten lamp loads. Add suffix H to catalog number.
2 Switching duty rated.
3 On the black handle breaker, add suffix “B” to the catalog number to obtain a tapped molded opening for proper use with hold-down kits.
4 For use as a branch circuit breaker in 400 and 600 ampere panels only.
All Type BR single-, two- and three-pole circuit breakers carry listing for HACR application. For circuit breakers with a shunt trip, add ST suffix.
Ampere
Rating
Wire Size Range
Cu/Al 60 °C or 75 °C
Single-Pole 120/240 Vac
Requires One 1-Inch (25.4 mm) Space
Two-Pole 120/240 Vac
Common Trip Requires Two
1-Inch (25.4 mm) Spaces
10 per Shelf Carton 5 per Shelf Carton
10 kAIC 22 kAIC 10 kAIC 22 kAIC 42 kAIC 65 kAIC
Catalog
Number
Catalog
Number
Catalog
Number
Catalog
Number
Catalog
Number
Catalog
Number
10 #14–4 BR110 — BR210 — — —
15 #14–4 BR115 12 BRH115 BR215
3 BRH215 — —
20 #14–4 BR120 12 BRH120 BR220
3 BRH220 — —
25 #14–4 BR125 BRH125 BR225
3 BRH225 — —
30 #14–4 BR130 BRH130 BR230
3 BRH230 — —
35 #14–4 BR135 BRH135 BR235
3 BRH235 — —
40 #14–4 BR140 BRH140 BR240
3 BRH240 3 ——
45 #14–4 — BRH145 BR245
3 BRH245 — —
50 #14–4 BR150 BRH150 BR250
3 BRH250 3 ——
55 #14–3 BR150 BRH155 BR255 BRH255 — —
60 #8–1/0 BR160 BRH160 BR260 BRH260 BRHH260 BRX260
70 #8–1/0 BR170 BRH170 BR270 BRH270 BRHH270 BRX270
80 #8–1/0 — — BR280 BRH280 BRHH280 BRX280
90 #8–1/0 — — BR290 BRH290 BRHH290 BRX290
100 #8–1/0 — — BR2100 BRH2100 BRHH2100 BRX2100
110 #8–1/0 — — BR2110 BRH2110 BRHH2110 BRX2110
125 #4–2/0 — — BR2125 BRH2125 BRHH2125 BRX2125
150 #4–2/0 — — BR2150
4 ———
BR120
BR215
BR320
BRH2100
BRX2125
1
1.2Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers
BR Circuit Breakers
BR Circuit Breakers
Product Description
.
Plug-On Combination Type
Arc Fault Circuit Breakers,
Type BR—10 kAIC, 120 Vac
and 120/240 Vac
A combination type arc
fault circuit interrupter is a
device that includes all of
the protection offered by the
branch feeder AFCI (mitigation
of high current arcing faults in
the complete circuit, including
connected cords). In addition
it provides direct detection of
persistent low current arcing
faults down to 5 amps with
associated mitigation of
fire hazards in the cords
connected to the outlets. High
current arcing faults can occur
from line to neutral or line to
ground. These arcing faults
are in parallel with the load
and produce the most energy
of all arcing faults. The current
level of low current arcing
faults is limited by the load.
Plug-On Combination Type Arc Fault Circuit Breakers, Type BR—10 kAIC, 120 Vac and 120/240 Vac
BRCAF115 Type BR, 1-Inch (25.4 mm) wide FIRE-GUARD Combination Type AFCI
Circuit Breakers
Poles
Ampere
Rating Configuration
Catalog
Number
Single-pole
10 kAIC
15 AFCI BRCAF115 1
Diagnostic AFCI BRACAF115
20 AFCI BRCAF120 1
Diagnostic AFCI BRACAF120
Single-pole
22 kAIC
15 AFCI BRHCAF115 1
20 AFCI BRHCAF120 1
Two-pole
10 kAIC
15 AFCI BRL215CAF
20 AFCI BRL220CAF