HomeMy WebLinkAboutDemco - Electrical Detail Bill of Material Page 1 of 1 Project Name: STONE QUARRY Negotiation No: SY880507X4K1 General Order No: Alternate No: 0003 Item No. Qty Product Description 2 Group Metering Aluminum Bus, NON-EUSERC, Total Number of Structures: Catalog No 1MFS400RB Designation TOWNHOME Qty List of Materials 1 [1MFS400RB] MAIN SERVICE MODULE, 400A 1 PHASE MAIN FUSIBLE SWI 1 [1MM512RRLB] 1 PHASE RINGLESS WITH HORN BYPASS M.M., 125A 8 [BR260] Type BR Breaker 60A/2 Pole 120/240V 10K 1 [1MM412RRLB] 1 PHASE RINGLESS WITH HORN BYPASS M.M., 125A Item No. Qty Product Description 2 BR RESIDENTIAL BREAKERS Type BR Breaker 20/2 Pole 120/240V 10K Catalog No BR220B Designation TOWNHOUSES Qty List of Materials 2 Type BR Breaker 20/2 Pole 120/240V 10K Item No. Qty Product Description 1 Group Metering Aluminum Bus, NON-EUSERC, Total Number of Structures: Catalog No 3MFS800RB Designation APT Qty List of Materials 1 [3MFS800RB] MAIN SERVICE MODULE, 800A 3 PHASE MAIN FUSIBLE SWI 2 [3MM612RRLB] 3 PHASE RINGLESS WITH HORN BYPASS M.M., 125A 2 [BRHH2100] Type BR Breaker 100A/2 Pole Com. Trip 120/240V 42K 17 [BRHH260] Type BR Breaker 60A/2 Pole Com. Trip 120/240V 42K 1 [3MM412RRLB] 3 PHASE RINGLESS WITH HORN BYPASS M.M., 125A 1 [3MM312RRLB] 3 PHASE RINGLESS WITH HORN BYPASS M.M., 125A 1 [37MM140R1240300] 3 Phase, 7 Jaw Comm Meter Module, 1 socket, 300A T Eaton Selling Policy 25-000 applies. All orders must be released for manufacture within 90 days of date of order entry. If approval drawings are required, drawings must be returned approved for release within 60 days of mailing. If drawings are not returned accordingly, and/or if shipment is delayed for any reason, the price of the order will increase by 1.0% per month or fraction there of for the time the shipment is delayed. Group Metering General Information Specifications Utility Approval NON-EUSERC Bus Type Aluminum Breaker Information 8 BR260 Type BR Breaker 60A/2 Pole 120/240V 10K Miscellaneous Specifications Approval Drawings:No Autocad Drawings:No Standard Instructions Books:No Certified Test Report (Std):No Enclosure Properties Struct #Width Depth Description/Modifications Catalog Number 1 20 11.75 Structure, 1MFS400RB 2 12.26 7.015 Structure, 1MM512RRLB 3 12.26 7.015 Structure, 1MM412RRLB Total of 3 Structures, Total Width of 44.52 Inches NEG-ALT Number PREPARED BY DATE APPROVED BY DATE VERSION REVISION DWG SIZE JOB NAME DESIGNATION TYPE G.O. DRAWING TYPE ITEM SHEET The information on this document is created by Eaton Corporation. It is disclosed in confidence and it is only to be used for the purpose in which it is supplied. SY880507X4K1-0003 SY88 12/17/2014 8.0.0.0 0 A Eaton STONE QUARRY TOWNHOME Group Metering Customer Appr. 1 of 2 1 Main 3 1 2 3 4 2 1 2 3 4 5 Structure 1 2 3 Wdth-Inches Wdth-MM 20 12.26 12.26 508 311 311 Depth-Inches Depth-MM 11.75 7.015 7.015 298 178 178 Height-Inches Height-MM 47.625 57.5 48.5 1209 1460 1231 Tab Size-Inches Tab Size-MM 2 50 NEG-ALT Number PREPARED BY DATE APPROVED BY DATE VERSION REVISION DWG SIZE JOB NAME DESIGNATION TYPE G.O. DRAWING TYPE ITEM SHEET The information on this document is created by Eaton Corporation. It is disclosed in confidence and it is only to be used for the purpose in which it is supplied. SY880507X4K1-0003 SY88 12/17/2014 8.0.0.0 0 A Eaton STONE QUARRY TOWNHOME Group Metering Customer Appr. 2 of 2 Group Metering General Information Specifications Utility Approval NON-EUSERC Bus Type Aluminum Breaker Information 2 BRHH2100 Type BR Breaker 100A/2 Pole Com. Trip 120/240V 42K 17 BRHH260 Type BR Breaker 60A/2 Pole Com. Trip 120/240V 42K Miscellaneous Specifications Approval Drawings:No Autocad Drawings:No Standard Instructions Books:No Certified Test Report (Std):No Enclosure Properties Struct #Width Depth Description/Modifications Catalog Number 1 20 11.75 Structure, 3MFS800RB 2 12.26 7.015 Structure, 3MM612RRLB 3 12.26 7.015 Structure, 3MM612RRLB 4 12.26 7.015 Structure, 3MM412RRLB 5 12.26 7.015 Structure, 3MM312RRLB 6 18.25 9.56 Structure, 37MM140R1240300 Total of 6 Structures, Total Width of 87.29 Inches Note: 400A KD-type breakers are factory installed in the 400A Commercial Stacks NEG-ALT Number PREPARED BY DATE APPROVED BY DATE VERSION REVISION DWG SIZE JOB NAME DESIGNATION TYPE G.O. DRAWING TYPE ITEM SHEET The information on this document is created by Eaton Corporation. It is disclosed in confidence and it is only to be used for the purpose in which it is supplied. SY880507X4K1-0003 SY88 12/17/2014 8.0.0.0 0 A Eaton STONE QUARRY APT Group Metering Customer Appr. 1 of 2 1 Main 5 1 2 3 2 1 2 3 4 5 6 3 1 2 3 4 5 6 4 1 2 3 4 6 1 Structure 1 2 3 4 5 6 Wdth-Inches Wdth-MM 20 12.26 12.26 12.26 12.26 18.25 508 311 311 311 311 463 Depth-Inches Depth-MM 11.75 7.015 7.015 7.015 7.015 9.56 298 178 178 178 178 242 Height-Inches Height-MM 47.625 66.5 66.5 48.5 41.8 52.65 1209 1689 1689 1231 1061 1337 Tab Size-Inches Tab Size-MM 2 50 NEG-ALT Number PREPARED BY DATE APPROVED BY DATE VERSION REVISION DWG SIZE JOB NAME DESIGNATION TYPE G.O. DRAWING TYPE ITEM SHEET The information on this document is created by Eaton Corporation. It is disclosed in confidence and it is only to be used for the purpose in which it is supplied. SY880507X4K1-0003 SY88 12/17/2014 8.0.0.0 0 A Eaton STONE QUARRY APT Group Metering Customer Appr. 2 of 2 Volume 1—Residential and Light Commercial CA08100002E—September 2012 www.eaton.com V1-T5-129 5 5.11Metering Products Group Metering 35MM, 37MM, 35SS and 37SS Commercial Meter Stack Modules (35MM, 37MM, 35SS and 37SS) Commercial Meter Stack Modules Product Description ●Heavy-duty lever bypass socket design ●Single-phase or three- phase designs (35 = single- phase, 37 = three-phase) ●Provision for two-pole or three-pole main tenant breakers ●Phase balance kits are included with three-high and four-high modules Features, Benefits and Functions A. End Walls The top cap is removable and does not contain knockouts, so contractors can position and punch holes where they need them. There are numerous KOs in the back and bottom for flexibility. B. Ground Bars The factory-installed equipment ground bars are provided in both the top and bottom gutters. C. Meter Socket The 5-jaw meter socket and 7-jaw meter socket includes a built-in manual bypass and jaw release. The ground wire is factory connected in both 35MM and 37MM modules. D. Separate Wireway Cover If work on the breakers or cables is necessary, it can be accomplished without disturbing the meters or meter covers, thanks to a separate cover that allows easy access to the module’s main tenant breaker and wireway section. (Not shown.) E. Barrier A solid metal barrier separates the meter socket section from the tenant breaker in the wireway section. The unmetered vertical bus is enclosed to guard against power theft. F. Neutral Assembly Located in the wireway of each module, the assembly permits convenient termination of the neutral conductors. G. Enclosed Horizontal Bus Non-removable metal barrier encloses 1200A horizontal bus when passing through the tenant breaker section for added security. H. Tenant Breaker Range All modules accept 15–225A bolt-on breakers in various AIC ratings. The CHH_X breaker carries a UL listed series rating of 100,000A, which allows you to use standard 10 kAIC breakers in downstream loadcenters and panelboards by Eaton. I. Indoor/Outdoor Construction Raintight caps, meter covers and lockable raintight tenant breaker covers make it convenient for you to use any of our modules on either NEMA 1 or NEMA 3R applications. J. Mounting Rail Rear mounting rail and wall hanger speed and simplify installation. (Mounting rail not shown.) K. Nameplate and Ratings The nameplate gives you full rating data: 208Y/120, three- phase, four-wire; 240/120, three-phase, four-wire delta (high leg on B-phase); and 240/120 single-phase. (Not shown.) L. Mains and Modules Slip together quickly, smoothly with front- accessible captive bolts securing the juncture without removing socket interiors or bus access plate. Main bus joint bolts torque to 25 foot pounds. V1-T5-130 Volume 1—Residential and Light Commercial CA08100002E—September 2012 www.eaton.com 5 5.11 Metering Products Group Metering 37MM Meter Stack Module ●Eaton’s 35MM and 37MM modular metering stacks contain meter sockets with built-in manual bypass and jaw release (Non-EUSERC areas) ●Eaton’s 35SS and 37SS stacks use meter sockets with test bypass feature (meets EUSERC electrical requirements) ●All commercial modular metering stacks contain four horizontal cross buses ●Mechanically and electrically built to bolt-up with main service modules and residential modular metering stacks Catalog Number Selection Commercial Meter Stack Modules When Ordering: 1. Determine catalog number of Main Service Module. 2. Determine catalog number of Meter Stack (Residential or Commercial). 3. Find quantity and catalog numbers for tenant circuit breakers (found on Page V1-T5-136). Order one breaker per socket. 4. If any accessories are needed, order from Pages V1-T5-138 and V1-T5-139. L B G F E H C I A Phases Three-phase only Number of Jaws 5 or 7 Socket Amperage 20 = 200A 40 = 400A Number of Meters 1, 2, 3 or 4 Socket Type K = K Base bolt-on socket Blank = Plug-in type socket Type of Metering MM = Commercial metering module SS = Safety socket—EUSERC Bus 12 = 1200A main bus ampacity AB = Phases A&B—EUSERC AC = Phases A&C—EUSERC BC = Phases B&C—EUSERC Enclosure R = NEMA 3R Tenant Breakers 40 = 400A included Blank = Ordered separately Bus C = Copper Blank = Aluminum 3 7 MM 1 40 R 12 40 K C V1-T5-132 Volume 1—Residential and Light Commercial CA08100002E—September 2012 www.eaton.com 5 5.11 Metering Products Group Metering 37MM ●Each socket is a 7 terminal block with lever bypass and jaw release ●Ringless covers ●Provision for three-pole main tenant breakers (circuit breakers not included). For circuit breaker catalog numbers, refer to Page V1-T5-136 ●Indoor/outdoor construction ●Main tenant breakers can exit top, bottom or back ●If being used in outdoor application and exiting the top, mount Myer type hubs on rainproof cap ●Short-circuit ratings up to 100A rms symmetrical depending upon the kAIC rating of installed main tenant circuit breakers and main device ●Non-EUSERC areas 37MM—Three-Phase Commercial Meter Stack Modules (Three-Phase In, Three-Phase Out) Notes 1 If a socket in a 37MM meter stack module needs to be single-phase, order 37MM1CK. This will convert the three-phase socket to single-phase. 2 EHD main tenant breakers require one 37MMCBK kit per breaker. 3 320A continuous rated socket with provisions for two main tenant breakers. 4 Unit is bottom exit only. 5 Rated at 100 kAIC. 6 Rated at 25 kAIC. 7 Rated at 35 kAIC. System Voltage Ampere Rating Per Meter Socket Number of Meter Sockets Horizontal Bus Ampacity/ Material Number of Jaws Per Meter Socket 1 Main Tenant Breaker Type (Page V1-T5-136) Catalog Number 208Y/120V, three-phase, four-wire 240/120V, three-phase, four-wire delta (B-phase is high leg) 225 1 1200 Al 7 Bolt-on type 37MM120R12 1 1200 Cu 7 37MM120R12C 2 1200 Al 7 EHD3_ 2 37MM220R12 2 1200 Cu 7 37MM220R12C 3 1200 Al 7 CC3_X 37MM320R12 3 1200 Cu 7 37MM320R12C 4 1200 Al 7 CHH3_H2X 37MM420R12 4 1200 Cu 7 37MM420R12C 400 1 1200 Al 7 CHH3_H4X CHH3_ 37MM140R12 3 1 1200 Cu 7 37MM140R12C 3 400 1 1200 Al 7 400A K-Frame included 37MM140R1240 4 1200 Cu 7 37MM140R1240C 4 400 1 1200 Al 7 400A K-Frame included 37MM140HR1240 5 1200 Cu 7 37MM140HR1240C 5 400 2 1200 Al 7 400A K-Frame included 37MM240R1240 2 1200 Cu 7 37MM240R1240C 400 continuous 1 1200 Cu 7 400A L-Frame included 37MM140R1240KC 6 400 continuous 1 1200 Cu 7 400A L-Frame included 37MM140HR1240KC 7 V1-T5-134 Volume 1—Residential and Light Commercial CA08100002E—September 2012 www.eaton.com 5 5.11 Metering Products Group Metering Approximate Dimensions in Inches (mm) Commercial Stacks (35MM and 37MM) 35MM and 37MM 19.25 (489.0) 66.63 (1692.3)25.38 (644.5) 14.00 (355.6) Typ. 52.63 (1336.7) 52.63 (1336.7) 8.75 (222.3) 35MM140R1240 37MM140R1240 same as below except eliminate top socket. 18.25 (463.6) 8.75 (222.3) 18.25 (463.6) 8.75 (222.3) 18.25 (463.6) 8.75 (222.3) V4-T2-154 Volume 4—Circuit Protection CA08100005E—June 2014 www.eaton.com 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2.3 Molded Case Circuit Breakers Series C Typical K-Frame Circuit Breaker Contents Description Page Product Overview. . . . . . . . . . . . . . . . . . . . . . . . . . .V4-T2-110 Standards and Certifications. . . . . . . . . . . . . . . . . . .V4-T2-111 Quick Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . .V4-T2-112 G-Frame (15–100 Amperes) . . . . . . . . . . . . . . . . . . .V4-T2-115 F-Frame (10–225 Amperes) . . . . . . . . . . . . . . . . . . .V4-T2-129 J-Frame (70–250 Amperes). . . . . . . . . . . . . . . . . . . .V4-T2-146 K-Frame (70–400 Amperes) Catalog Number Selection. . . . . . . . . . . . . . . . . .V4-T2-155 Product Selection . . . . . . . . . . . . . . . . . . . . . . . .V4-T2-157 Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . .V4-T2-174 Technical Data and Specifications . . . . . . . . . . . .V4-T2-175 Dimensions and Weights . . . . . . . . . . . . . . . . . .V4-T2-178 L-Frame (125–600 Amperes) . . . . . . . . . . . . . . . . . .V4-T2-179 M-Frame (300–800 Amperes). . . . . . . . . . . . . . . . . .V4-T2-205 N-Frame (400–1200 Amperes) . . . . . . . . . . . . . . . . .V4-T2-216 R-Frame (800–2500 Amperes) . . . . . . . . . . . . . . . . .V4-T2-231 Motor Circuit Protectors (MCP) . . . . . . . . . . . . . . . .V4-T2-250 Motor Protection Circuit Breakers (MPCB). . . . . . . .V4-T2-261 Type ELC Current Limiter Attachment (Size 0–4) . . . . .V4-T2-263 Current Limiting Circuit Breaker Module . . . . . . . . . . .V4-T2-264 Internal Accessories . . . . . . . . . . . . . . . . . . . . . . . . .V4-T2-268 External Accessories . . . . . . . . . . . . . . . . . . . . . . . .V4-T2-299 K-Frame (70–400 Amperes) Product Description ●All Eaton K-Frame circuit breakers are HACR rated ●K-Frame circuit breakers are available as individual components (frame, trip unit, terminals), or factory assembled complete breakers ●K-Frame circuit breakers with non-interchangeable trip units are suitable for reverse feed use Volume 4—Circuit Protection CA08100005E—June 2014 www.eaton.com V4-T2-157 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2.3Molded Case Circuit Breakers Series C Product Selection Types KD, HKD and KDC Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units Notes 1 Magnetic trip adjustable 5–10 times continuous ampere rating. 2 Individually packed. 3 2TA400K, 3TA400K and 4TA400K terminal kits contain one terminal for each pole and one terminal cover. Maximum Continuous Ampere Rating at 40°C Standard Interrupting Capacity 600 Vac Rated 35 kAIC at 480 Vac High Interrupting Capacity 600 Vac Rated 65 kAIC at 480 Vac Ultra High Interrupting Capacity Current Limiting 600 Vac Rated 100 kAIC at 480 Vac Thermal-Magnetic Trip Unit Only 1 For Use with Standard or High or Ultra High Interrupting Frames Standard Terminals Only See Page V4-T2-173 for Optional Terminals Factory Assembled Circuit Consisting of Frame, Trip Unit and Terminals 1 Factory Assembled Circuit Consisting of Frame, Trip Unit and Terminals 1 Factory Assembled Circuit Consisting of Frame, Trip Unit and Terminals 1 Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number Two-Pole 100 KD2100 HKD2100 KDC2100 KT2100T TA300K 2 125 KD2125 HKD2125 KDC2125 KT2125T TA300K 2 150 KD2150 HKD2150 KDC2150 KT2150T TA300K 2 175 KD2175 HKD2175 KDC2175 KT2175T TA300K 2 200 KD2200 HKD2200 KDC2200 KT2200T TA300K 2 225 KD2225 HKD2225 KDC2225 KT2225T TA300K 2 250 KD2250 HKD2250 KDC2250 KT2250T TA350K 2 300 KD2300 HKD2300 KDC2300 KT2300T TA350K 2 350 KD2350 HKD2350 KDC2350 KT2350T TA350K 2 400 KD2400 HKD2400 KDC2400 KT2400T 2TA400K 3 Three-Pole 100 KD3100 HKD3100 KDC3100 KT3100T TA300K 2 125 KD3125 HKD3125 KDC3125 KT3125T TA300K 2 150 KD3150 HKD3150 KDC3150 KT3150T TA300K 2 175 KD3175 HKD3175 KDC3175 KT3175T TA300K 2 200 KD3200 HKD3200 KDC3200 KT3200T TA300K 2 225 KD3225 HKD3225 KDC3225 KT3225T TA300K 2 250 KD3250 HKD3250 KDC3250 KT3250T TA350K 2 300 KD3300 HKD3300 KDC3300 KT3300T TA350K 2 350 KD3350 HKD3350 KDC3350 KT3350T TA350K 2 400 KD3400 HKD3400 KDC3400 KT3400T 3TA400K 3 Four-Pole 100 KD4100 HKD4100 KDC4100 KT3100T TA300K 2 125 KD4125 HKD4125 KDC4125 KT3125T TA300K 2 175 KD4175 HKD4175 KDC4175 KT3175T TA300K 2 200 KD4200 HKD4200 KDC4200 KT3200T TA300K 2 225 KD4225 HKD4225 KDC4225 KT3225T TA300K 2 250 KD4250 HKD4250 KDC4250 KT3250T TA350K 2 300 KD4300 HKD4300 KDC4300 KT3300T TA350K 2 350 KD4350 HKD4350 KDC4350 KT3350T TA350K 2 400 KD4400 HKD4400 KDC4400 KT3400T 4TA400K 3 V1-T5-118 Volume 1—Residential and Light Commercial CA08100002E—September 2012 www.eaton.com 5 5.11 Metering Products Group Metering 1MM and 3MM Metering Stack Modules Residential Meter Stacks Features, Benefits and Functions A. Barrier Meter socket and tenant main breaker/wireway sections are separated by a solid metal barrier to guard unmetered bus against power theft. B. Tenant Breaker Reliable bus bar-to-bus bar connection. 200A modules accept bolt-on breakers 60– 200A. 125A modules accept 15–125A plug-on breakers. C. Moveable Phase Connector Four-wire horizontal bus lets you use any 3MM module for single- or three-phase incoming service. Shipped with A and B phase connection, phase balancing is easily accomplished in the field by moving one, front- accessible phase connector post per module. D. Neutral Assembly A convenient termination for neutral conductors is in the wireway of each module. E. Enclosed Horizontal Bus Added security because a non-removable barrier encloses the 800 or 1200A horizontal bus passing through tenant breaker section. F. Equipment Ground Bar Factory installed in side gutter, a standard feature that’s moveable to the top or bottom gutter. G. Raintight Cap Shipped on each outdoor meter module and main device. H. Knockouts Tangential in bottom endwall. I. Superior Finish Rust inhibiting phosphate primer and gray baked enamel is standard. All outdoor enclosures are of galvanized steel construction. J. Meter Socket Our unique meter socket base is installed without any fasteners—reducing chances for hot spots, easily replaceable, and improves connection to vertical bus. K. Bus Connection Mains and modules slip together quickly and smoothly with front- accessible captive bolts securing the juncture without removing socket interiors or bus access plate. Main bus joint bolts torque to 25 foot pounds. L. Separate Wireway Cover Separate covers allow easy access to tenant breaker and wireway section, permit work on breakers or in wireway without disturbing meters or meter covers. (Not shown.) M. Vertical Bus Bar One-piece vertical bus bar from phase balancing joints to meter socket eliminating any chance for hot spots. 1MM Meter Stack Module K F E A B G M J C H D I Volume 1—Residential and Light Commercial CA08100002E—September 2012 www.eaton.com V1-T5-119 5 5.11Metering Products Group Metering ●Eaton’s 1MM stacks are single-phase in, single- phase out design ●Eaton’s 3MM stacks are three-phase in, single- phase out design ●Stacks with single-phase horizontal bus are rated 240/120V, single-phase, three-wire. Stacks with three-phase horizontal bus are rated 208Y/120V, three- phase, four-wire, but can be used on 240/120V, three-phase, four-wire delta systems ●All three-phase horizontal bus modules have four- wire cross bus, connected A-B phase to vertical bus, readily reconnectable for phase balance on installation Note: Individual sockets cannot be phase balanced, only each stack. ●Short-circuit ratings up to 100,000A rms symmetrical depending upon AIC rating of installed main tenant circuit breakers and main device ●Main tenant feeders can exit bottom or back. Knockouts are available at all exit locations ●If being used in outdoor application and exiting the top, mount Myer type hubs on rainproof cap ●Provision for two-pole breaker (plug-on type for 125A sockets and bolt-on type for 200A sockets)— circuit breakers not included ●Mechanically and electrically built to bolt-up with main service modules and commercial modular metering stacks ●Aluminum or copper bus ●800 or 1200A horizontal bus ●All 3MM stacks include fifth jaw at 9 o’clock position ●All 1MM stacks do not include fifth jaw. Order 1MM5JK if needed Catalog Number Selection When Ordering: 1. Determine catalog number of Main Service Module. 2. Determine catalog number of Meter Stack (Residential or Commercial). 3. Find quantity and catalog numbers for tenant circuit breakers (found on Page V1-T5-127 or V1-T5-137). Order one breaker per socket. 4. If any accessories are needed, order from Pages V1-T5-138 and V1-T5-139. Phases 1 = Single-phase 3 = Three-phase Options Blank = Ring RL = Ringless RLB = Ringless with horn bypass WB = Wall bracket (accessory) BSK = Bussed spacer (accessory) EB12 = 12-inch (304.8 mm) elbow (accessory) EB16 = 16-inch (406.4 mm) elbow (accessory) Number of Meters 2, 3, 4, 5 or 6 Blank = Accessory Bus Type Blank = Aluminum C = Copper Type of Metering MM = Multiple metering Ampere Rating 12 = 125A 20 = 200A Blank = Accessory Enclosure R = Outdoor Blank = Indoor Bus Amperes 12 = 200A horizontal bus (3MM units only) Blank = Standard 800A bus 1 MM 4 12 R 12 C V1-T5-120 Volume 1—Residential and Light Commercial CA08100002E—September 2012 www.eaton.com 5 5.11 Metering Products Group Metering Product Selection 800A Horizontal Aluminum Bus—Standard Offering Notes 1 For indoor applications where a top endwall with knockouts is needed, order one of part number MM12N1WLK for each 125A stack or MM20N1WLK for each 200A stack. 2 1MM units do not come with 5th jaw. 3 To change in field from ring to ringless—order 1MMRC125. 4 To change in field from ring to ringless, the top socket in 125A, two- and three-high stacks use 1MMRC125T. Top socket only—other sockets see 3. 5 To change in field from ring to ringless—order 1MMRC200. 6 Check with local utility for height requirements or restrictions. Amperes Per Meter Socket Number of Meter Sockets Bus Ampacity Enclosure Type 1 Main Tenant Breaker Type (For Specific Catalog Numbers, Refer to Page V1-T5-127) Single-Phase In, Single-Phase Out Three-Phase In, Single-Phase Out Single-Phase Horizontal Bus (Three Horizontal Bus Bars— A, B and Neutral) 2 Three-Phase Horizontal Bus (Four Horizontal Bus Bars— A, B, C and Neutral) Catalog Number Catalog Number Ring Style Meter Socket Covers 125 3 2 4 800 Indoor/outdoor BR2_ BRH2_ BRHH2_ Use three-phase 3MM212R 3 4 800 Indoor/outdoor 1MM312R 3MM312R 4 800 Indoor/outdoor 1MM412R 3MM412R 5 800 Indoor/outdoor 1MM512R 3MM512R 6 800 Indoor/outdoor 1MM612R 3MM612R 200 5 2 800 Outdoor CCV2_X, CHH2_H2X CHH2_H4X, CHH2_X Use three-phase 3MM220R 3 800 Outdoor 1MM320R 3MM320R 4 800 Outdoor 1MM420R 3MM420R 5 800 Outdoor 1MM520R 6 3MM520R 5 Ringless Style Meter Socket Covers 125 2 800 Outdoor BR2_ BRH2_ BRHH2_ Use three-phase 3MM212RRL 3 800 Outdoor 1MM312RRL 3MM312RRL 4 800 Outdoor 1MM412RRL 3MM412RRL 5 800 Outdoor 1MM512RRL 3MM512RRL 6 800 Outdoor 1MM612RRL 3MM612RRL 200 2 800 Outdoor CCV2_X, CHH2_H2X CHH2_H4X, CHH2_X Use three-phase 3MM220RRL 3 800 Outdoor 1MM320RRL 3MM320RRL 4 800 Outdoor 1MM420RRL 3MM420RRL 5 800 Outdoor 1MM520RRL 6 3MM520RRL 5 Ringless Style Covers with Horn Bypass 125 2 800 Outdoor BR2_ BRH2_ BRHH2_ Use three-phase 3MM212RRLB 3 800 Outdoor 1MM312RRLB 3MM312RRLB 4 800 Outdoor 1MM412RRLB 3MM412RRLB 5 800 Outdoor 1MM512RRLB 3MM512RRLB 6 800 Outdoor 1MM612RRLB 3MM612RRLB 200 2 800 Outdoor CCV2_X, CHH2_H2X CHH2_H4X, CHH2_X CHH2_H4X, CHH2_X Use three-phase 3MM220RRLB 3 800 Outdoor 1MM320RRLB 3MM320RRLB 4 800 Outdoor 1MM420RRLB 3MM420RRLB 5 800 Outdoor 1MM520RRLB 6 3MM520RRLB 5 1MM and 3MM Metering Stack Modules V1-T5-124 Volume 1—Residential and Light Commercial CA08100002E—September 2012 www.eaton.com 5 5.11 Metering Products Group Metering Dimensions Approximate Dimensions in Inches (mm) Modular Metering Stacks—Aluminum and Copper 1MM, 3MM, 125 Amperes Note: Dimensions Apply to 800 and 1200 Ampere Horizontal Bus. This Bus Omitted On 1 — PH Units 41.80 (1061.7)9.00(228.6)9.00(228.6)12.61(320.2)3.07 (78.0)(6) KO for 1, 1-2/4 1-1/2 Conduit A 7.01 (178.0)34.25(870.0)To of Wall Mtg. ScrewCL21.65(550.0)C Meter to C Rail Mounting ScrewLL2.00 (50.8)TYP. 2, 3 Meter Device 4 Meter Device30.0(777.2)To C of Main Bus BarL48.50(1231.9)12.60(320.3)9.00(228.6)9.00(228.6)9.00(228.6)30.60 (777.2)To C of Main Bus BarL57.50 (1460.5)9.00(228.6)9.00(228.6)9.00(228.6)12.60(320.0)To C of Main Bus BarL30.60 (777.2) 5 Meter Device 6 Meter Device12.60(320.0)9.00(228.6)9.00(228.6)9.00(228.6)9.00(228.6)9.00(228.6)66.50 (1689.1) A 30.60 (777.2)To C of Main Bus BarLTop End & Bottom End View for NEMA 1; Bottom End View for NEMA 3R Tangential K.O.'s 3/4, 1, 1-1/4, 1-1/2 "Z" = C OF 1-1/2" Ring "Y" = C OF 1 1/4" Ring "X" = C OF 3/4" & 1" RingLLL 0.125 (3.2) 12.13 (308.1) 2.83 (71.9) 2.83 (71.9) 2.83 (71.9) 2.33 (59.1) 6.62 (168.1) 2.83 (71.9) 6.06 (153.9) 2.83 (71.9) 2.83 (71.9) 12.26 (311.4) 12.26 (311.4) 12.26 (311.4) 12.26 (311.4) "X" "Y""Z" Volume 1—Residential and Light Commercial CA08100002E—September 2012 www.eaton.com V1-T5-127 5 5.11Metering Products Group Metering BR2100/CC2200 1MM and 3MM Metering Circuit Breakers 1MP, 1MM and 3MM Main Tenant Circuit Breakers Product Description Specific main tenant circuit breakers that are to be used in meter packs (1MP), residential meter stacks (1MM) and three-phase in single-phase out meter stacks (3MM). Features, Benefits and Functions 1MP, 1MM and 3MM Main Tenant Circuit Breakers ●The following Eaton breakers are to be used on 1MP, 1MM and 3MM modular metering stacks ●Series rating information available on Pages V1-T5- 144 through V1-T5-147 ●120/240 Vac—field installed ●Three-phase, 400–1200A main circuit breakers ●Three-phase, 400–800A main fusible switches ●Simple bridge joint connection Product Selection Aluminum Bus—Main Lugs Not Included—See Page V1-T5-98 Description Number of Poles Main Tenant Circuit Breaker Ampere Rating 10 kAIC 22 kAIC 25 kAIC 42 kAIC 100 kAIC Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number Plug-on type circuit breakers used with 1MP, 1MM and 3MM 125A modular metering stacks 260BR260 BRH260 — BRHH260 — 270BR270 BRH270 — BRHH270 — 280BR280 BRH280 —BRHH280 — 290BR290 BRH290 —BRHH290 — 2100BR2100 BRH2100 —BRHH2100 — 2110BR2110 BRH2110 —BRHH2110 — 2125BR2125 BRH2125 —BRHH2125 — Bolt-on type circuit breakers used with 1MP, 1MM and 3MM 200A modular metering stacks 260——CHH2060H2X CHH2060H4X CHH2060X 270——CHH2070H2X CHH2070H4X CHH2070X 280——CHH2080H2X CHH2080H4X CHH2080X 290——CHH2090H2X CHH2090H4X CHH2090X 2100CCV2100X —CHH2100H2X CHH2100H4X CHH2100X 2125CCV2125X —CHH2125H2X CHH2125H4X CHH2125X 2150CCV2150X —CHH2150H2X CHH2150H4X CHH2150X 2175CCV2175X —CHH2175H2X CHH2175H4X CHH2175X 2200CCV2200X —CHH2200H2X CHH2200H4X CHH2200X V1-T1-76 Volume 1—Residential and Light Commercial CA08100002E—September 2014 www.eaton.com 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1.2 Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers Product Selection Plug-On Circuit Breakers, Types BR—10/22/42 kAIC, 120 Vac, 120/240 Vac and 240 Vac Type BR Breakers, 1-Inch (25.4 mm) per Pole 120/240, 10, 22 and 42 kAIC Notes 1 One pole, 1-inch (25.4 mm) per pole circuit breakers are available with high magnetic setting for switching large tungsten lamp loads. Add suffix H to catalog number. 2 Switching duty rated. 3 On the black handle breaker, add suffix “B” to the catalog number to obtain a tapped molded opening for proper use with hold-down kits. 4 For use as a branch circuit breaker in 400 and 600 ampere panels only. All Type BR single-, two- and three-pole circuit breakers carry listing for HACR application. For circuit breakers with a shunt trip, add ST suffix. Ampere Rating Wire Size Range Cu/Al 60 °C or 75 °C Single-Pole 120/240 Vac Requires One 1-Inch (25.4 mm) Space Two-Pole 120/240 Vac Common Trip Requires Two 1-Inch (25.4 mm) Spaces 10 per Shelf Carton 5 per Shelf Carton 10 kAIC 22 kAIC 10 kAIC 22 kAIC 42 kAIC 65 kAIC Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number 10 #14–4 BR110 — BR210 — — — 15 #14–4 BR115 12 BRH115 BR215 3 BRH215 — — 20 #14–4 BR120 12 BRH120 BR220 3 BRH220 — — 25 #14–4 BR125 BRH125 BR225 3 BRH225 — — 30 #14–4 BR130 BRH130 BR230 3 BRH230 — — 35 #14–4 BR135 BRH135 BR235 3 BRH235 — — 40 #14–4 BR140 BRH140 BR240 3 BRH240 3 —— 45 #14–4 — BRH145 BR245 3 BRH245 — — 50 #14–4 BR150 BRH150 BR250 3 BRH250 3 —— 55 #14–3 BR150 BRH155 BR255 BRH255 — — 60 #8–1/0 BR160 BRH160 BR260 BRH260 BRHH260 BRX260 70 #8–1/0 BR170 BRH170 BR270 BRH270 BRHH270 BRX270 80 #8–1/0 — — BR280 BRH280 BRHH280 BRX280 90 #8–1/0 — — BR290 BRH290 BRHH290 BRX290 100 #8–1/0 — — BR2100 BRH2100 BRHH2100 BRX2100 110 #8–1/0 — — BR2110 BRH2110 BRHH2110 BRX2110 125 #4–2/0 — — BR2125 BRH2125 BRHH2125 BRX2125 150 #4–2/0 — — BR2150 4 ——— BR120 BR215 BR320 BRH2100 BRX2125 Volume 1—Residential and Light Commercial CA08100002E—September 2012 www.eaton.com V1-T5-103 5 5.11Metering Products Group Metering Main Service Modules Product Description ●Main terminal box ●Main circuit breaker ●Main bolted pressure switch ●Main fusible switch ●Main fusible switch with pull box ●Underground pull box Application Description Main Circuit Breakers with Busway Connections The Service Entrance Product Team announces the availability of both main fusible switch and main circuit breaker group metering mains with busway connections. This offering provides us with the ability to offer multiple tenant metering in high rise apartment buildings where riser busway is used. Features, Benefits and Functions Eaton’s Main Service Module ●Offering: main terminal/lug compartment, main circuit breaker, main fusible switch, main bolted pressure switch, main fusible switch with pull box (meets EUSERC electrical requirements), underground pull box termination compartment without cross bus (meets EUSERC electrical requirements) ●Mechanically and electrically built for use with 1MM, 3MM, 35MM, 37MM, 35SS and 37SS modular metering stacks ●For integrated system short-circuit ratings with main devices, see series ratings on Page V1-T5-144 ●All main service modules include both left and right horizontal bus closure plates ●Two-pole devices are applied to single-phase, three-wire, 120/240V or 208Y/120V systems, three- pole devices to 208Y/240V or 120/240V delta systems ●Single-phase mains couple to any modular metering stack (1MM, 3MM, 35MM, 37MM, 35SS and 37SS) ●Three-phase mains require three-phase bussed stacks. These modular metering stacks are 3MM, 35MM, 37MM, 35SS and 37SS ●If the ampere rating of the main service module is greater than the horizontal bus rating of the meter stack (residential or commercial), the main service module must be center fed. Examples: 1200A Main Circuit Breaker (1MCB1200R) with an 800A residential stack (1MM512R). 1600A Main Terminal Box (3MTB1600R) with a 1200A residential stack (3MM212R12) ●Most main service modules are available with aluminum or copper bus Main Circuit Breakers with Busway Connections ●Three-phase, 400–200A main circuit breakers ●Three-phase, 400–800A main fusible switches ●Simple bridge joint connection ●Variety of options: ●Right or left mounting ●Internal ground or housing ground ●The MFS/MCB and busway connector are supplied completely assembled V1-T5-104 Volume 1—Residential and Light Commercial CA08100002E—September 2012 www.eaton.com 5 5.11 Metering Products Group Metering Catalog Number Selection When Ordering: 1. Determine catalog number of Main Service Module. 2. Determine catalog number of Meter Stack (Residential or Commercial). 3. Find quantity and catalog numbers for tenant circuit breakers (found on Page V1-T5-127 or V1-T5-137). Order one breaker per socket. 4. If any accessories are needed, order from Pages V1-T5-138 and V1-T5-139. Phase 1 = Single-phase 3 = Three-phase Ampere Rating 400A 600A 800A 1000A 1200A 1400A 1600A 2000A Bus Material C = Copper bus Blank= Aluminum bus Type of Metering BTB = Main terminal box MCB = Main circuit breaker BPS = Bolted pressure switch MFS = Main fusible switch UGPB = Underground pull box MTBE =Main terminal box with utility pull box MCBE =Main circuit breaker with utility pull box Accessories and Additional Options BLK= Box lug kit (accessory) CLK= Compression lug (accessory) B = Bottom feed T = Top feed UG= Pull box Blank= No options Enclosure R = NEMA 3R 3 MTB 400 R C V1-T5-108 Volume 1—Residential and Light Commercial CA08100002E—September 2012 www.eaton.com 5 5.11 Metering Products Group Metering Main Fusible Switches ●Fuses not included ●Main lugs and neutral included with device ●100 kAIC rating on switches with Class T fuses installed. If converting to Class H, the kAIC rating is 10 and if converted to Class R, the kAIC rating is 200 Note: This is the fuse rating, switch still rated at 100 kAIC. ●800A top and bottom fed units are supplied with Class T fuse clips as standard. The Class T fuse clips are field convertible to Class L by repositioning. No kit is needed ●Barrier kits available for 400A–800A fusible switches: Bottom feed—3MFSBBK, Top feed—3MFSTBK Main Fusible Switches Notes 1 If Class H fuse clips are needed, use catalog number WCG3HK400 (order (1) per phase). If Class R fuse clips are needed, order catalog number DS56FK in addition to WCG3HK400. In order to go from T to R, the device must first be converted to H. All kits are field installable and each DS56FK kit will convert three poles. 2 If Class H fuse clips are needed, use catalog number WCG3HK600 (order (1) per phase). If Class R fuse clips are needed, order catalog number DS66FK in addition to WCG3HK600. In order to go from T to R, the device must first be converted to H. All kits are field installable and each DS66FK kit will convert three poles. 3 Class T fuse clips provided are field convertible to Class L by repositioning. No kit is needed. 4 If compression lugs are being used, order 3MFS800CLK. This compression lug kit includes four pads (three poles and neutral). 5 1MFS600BLK (4) 3/0–750 kcmil/phase (one kit/phase and one kit/neutral). 6 If compression lugs are being used, order 3MFS800CLKT. This compression lug kit includes four pads (three poles and neutral). 7 IMFS1200LK (3) 750 kcmil/phase (one kit/phase). IMFS1200LKN (3) 750 kcmil (neutral). Ampere Rating Feed Class Fuse Clips (Fuses Not Included) Line Side Box Lugs and Wire Sizes (Included with Switch) System Voltage 120/240 Vac Single-Phase, Three-Wire 120/208 Vac Three-Phase, Four-Wire Catalog Number Catalog Number Aluminum Bus (Standard Offering) 400 Bottom T 1 (2) 1/0–300 kcmil or (1) 750 kcmil 45 1MFS400RB 3MFS400RB 400 Top T 1 (2) 1/0–300 kcmil or (1) 750 kcmil 56 1MFS400RT 3MFS400RT 600 Bottom T 2 (2) #2–600 kcmil 45 1MFS600RB 3MFS600RB 600 Top T 2 (2) #2–600 kcmil 56 1MFS600RT 3MFS600RT 800 Bottom T, L 3 (4) 3/0–750 kcmil 4 1MFS800RB 3MFS800RB 800 Top T, L 3 (4) 3/0–750 kcmil 6 1MFS800RT 3MFS800RT 1200 Bottom T, L 3 (4) #2–600 kcmil 7 1MFS1200RB 3MFS1200RB Copper Bus (Premium Offering) 400 Bottom T 1 (2) 1/0–300 kcmil or (1) 750 kcmil 45 1MFS400RBC 3MFS400RBC 400 Top T 1 (2) 1/0–300 kcmil or (1) 750 kcmil 56 1MFS400RTC 3MFS400RTC 600 Bottom T 2 (2) #2–600 kcmil 45 1MFS600RBC 3MFS600RBC 600 Top T 2 (2) #2–600 kcmil 56 1MFS600RTC 3MFS600RTC 800 Bottom T, L 3 (4) 3/0–750 kcmil 4 1MFS800RBC 3MFS800RBC 800 Top T, L 3 (4) 3/0–750 kcmil 6 1MFS800RTC 3MFS800RTC 1200 Bottom T, L 3 (4) #2–600 kcmil 7 1MFS1200RBC 3MFS1200RBC Main Fusible Switches V1-T5-112 Volume 1—Residential and Light Commercial CA08100002E—September 2012 www.eaton.com 5 5.11 Metering Products Group Metering Dimensions Approximate Dimensions in Inches (mm) Dimensions (Not to be Used for Construction Purposes) Main Device Width Height Depth Mounting Center Line of Wall Mounting Bracket Knockouts in Bottom Endwalls Except No KOs for Top Feed Switch or Bolted Pressure Switch Conduit Diameter KO Dwg.ABCDEF Inches mm Terminal Box 400 and 600A 13.50 (342.9) 48.75 (1238.3) 7.00 (177.8) —54.00 (1371.6) 30.63 (777.9)(1) 2.50, 3.00, 3.50, 4.00 (1) 0.50 (1) 63.5, 76.2, 88.9, 101.6 (1) 12.7 1 800 and 1200A 20.00 (508.0) 47.63 (1209.8) 11.75 (298.5) 12.00 (304.8) 51.50 (1308.1) 30.63 (777.9)(2) 0.50, 0.75, 1.00 (4) 2.00, 2.50, 3.00, 3.50, 4.00 (2) 12.1, 19.1, 25.4 (4) 50.8, 63.5, 76.2, 88.9, 101.6 2 1600A 32.88 (835.2) 60.13 (1527.3) 11.44 (290.6) 16.00 (406.4) 64.13 (1628.9) 38.59 (980.2)(1) 0.75, 1.00, 1.25, 1.50 (5) 3.00, 3.50, 4.00, 5.00 (1) 19.1, 25.4, 31.8, 38.1 (5) 76.2, 88.9, 101.6, 127.0 3 Main Circuit Breaker with Box Lugs 400–1200A 20.00 (508.0) 47.63 (1209.8) 11.75 (298.5) 12.00 (304.8) 51.50 (1308.1) 30.63 (777.9)(2) 0.50, 0.75, 1.00 (4) 2.00, 2.50, 3.00,3.50, 4.00 (2) 12.7, 19.1, 25.4 (4) 50.8, 63.5, 76.2, 88.9, 101.6 2 1400–2000A 24.88 (632.0) 57.13 (1451.0) 14.88 (378.0) 16.00 (406.4) 57.13 (1451.0) 44.00 (1117.6)——— Main Circuit Breaker with Compression Lugs 400–1200A 20.00 (508.0) 61.00 (1549.4) 11.75 (298.5) 12.00 (304.8) 65.00 (1651.0) 44.00 (1117.6)(2) 0.50, 0.75, 1.00 (4) 2.00, 2.50, 3.00, 3.50, 4.00 (2) 12.7, 19.1, 25.4 (4) 50.8, 63.5, 76.2, 88.9, 101.60 2 Main Fusible Switch Bottom feed 400–800A 20.00 (508.0) 47.63 (1209.8) 11.75 (298.5) 12.00 (304.8) 51.50 (1308.1) 30.63 (777.9)(2) 0.50, 0.75, 1.00 (4) 2.00, 2.50, 3.00, 3.50, 4.00 (2) 12.7, 19.1, 25.4 (4) 50.8, 63.5, 76.2, 88.9, 101.6 2 Top feed 400–800A 20.00 (508.0) 47.63 (1209.8) 11.75 (298.5) 12.00 (304.8) 51.50 (1308.1) 18.13 (460.4)(2) 0.50, 0.75, 1.00 (4) 2.00, 2.50, 3.00, 3.50, 4.00 (2) 12.7, 19.1, 25.4 (4) 50.8, 63.5, 76.2, 88.9, 101.6 2 1200A 33.50 (850.9) 52.75 (1339.9) 11.88 (301.8) 16.00 (406.4) 56.25 (1428.8) 30.75 (781.1)(5) 3.50, 4.00, 5.00 (1) 0.75, 1.00, 1.25, 1.50 (5) 88.9, 101.6, 127.0 (1) 19.1, 25.4, 31.8, 38.1 4 Bolted Pressure Switch 36.50 (927.1) 66.50 (1689.1) 19.50 (495.3) 28.00 (711.2) 60.00 (1524.0) 30.63 (777.9)——— Main Fusible Switch with Pull Box 400A 20.00 (508.0) 61.00 (1549.4) 11.75 (298.5) 12.00 (304.8) 65.00 (1651.0) 44.00 (1117.6)(2) 0.50, 0.75, 1.00 (4) 2.00, 2.50, 3.00, 3.50, 4.00 (2) 12.7, 19.1, 25.4 (4) 50.8, 63.5, 76.2, 88.9, 101.6 2 600 and 800A (single-phase) 20.00 (508.0) 61.00 (1549.4) 11.75 (298.5) 12.00 (304.8) 65.00 (1651.0) 44.00 (1117.6)(2) 0.50, 0.75, 1.00 (4) 2.00, 2.50, 3.00, 3.50, 4.00 (2) 12.7, 19.1, 25.4 (4) 50.8, 63.5, 76.2, 88.9, 101.6 2 600 and 800A (three-phase) 25.06 (636.5) 61.00 (1549.4) 11.75 (298.5) 17.00 (431.8) 65.00 (1651.0) 44.00 (1117.6)(2) 0.50, 0.75, 1.00 (4) 2.00, 2.50, 3.00, 3.50, 4.00 (2) 12.7, 19.1, 25.4 (4) 50.8, 63.5, 76.2, 88.9, 101.6 4 1200A 33.50 (850.9) 61.50 (1562.1) 11.88 (301.8) 16.00 (406.4) 65.25 (1657.4) 48.00 (1219.2)(5) 3.50, 4.00, 5.00 (1) 0.75, 1.00, 1.25, 1.50 (5) 88.9, 101.6, 127.0 (1) 19.1, 25.4, 31.8, 38.1 4 Main Circuit Breaker with Pull Box (EUSERC) 400A 20.01 (508.2) 60.44 (1535.2) 11.14 (283.0) 12.00 (304.8) 65.11 (1653.8) 39.75 (1009.6)(4) 2.50, 3.00, 3.50, 4.00 (4) 63.5, 76.2, 88.9, 101.6 2 800A 24.88 (632.0) 60.94 (1547.9) 11.14 (283.0) 17.00 (431.8) 64.88 (1648.0) 39.81 (1011.2)(4) 2.50, 3.00, 3.50, 4.00 (4) 63.5, 76.2, 88.9, 101.6 2 1200A 33.00 (838.2) 61.14 (1553.0) 11.32 (287.5) 16.00 (406.4) 65.25 (1657.4) 43.56 (1106.4)(4) 2.50, 3.00, 3.50, 4.00 (4) 63.5, 76.2, 88.9, 101.6 4 Pull Box 400A 16.38 (416.1) 44.88 (1140.0) 7.88 (200.2) 8.00 (203.2) 45.75 (1162.1) 28.63 (727.2)(2) 4.00 101.6 5 800A 24.38 (619.3) 46.88 (1190.8) 11.88 (301.8) 12.00 (304.8) 47.75 (1212.9) 32.25 (819.2)(3) 4.00 101.6 6 1200A 32.50 (825.5) 56.88 (1444.8) 12.00 (304.8) 17.75 (450.9) 57.75 (1466.9) 42.25 (1073.2)(4) 5.00 127.0 7 EUSERC Bussed Pull Section Single-phase 400 and 800A 20.13 (511.3) 61.00 (1549.4) 11.25 (285.8) 12.00 (304.8) 64.88 (1648.0) 44.00 (1117.6)(4) 2.50, 3.00, 3.50, 4.00 (4) 63.5, 76.2, 88.9, 101.6 5 Three-phase 400 and 800A 25.13 (638.3) 61.00 (1549.4) 11.88 (301.8) 17.00 (431.8) 64.88 (1648.0) 44.00 (1117.6)(4) 2.50, 3.00, 3.50, 4.00 (4) 63.5, 76.2, 88.9, 101.6 6 EUSERC Main Terminal Box Single-phase 400 and 800A 20.13 (511.3) 61.00 (1549.4) 11.88 (301.8) 12.00 (304.8) 64.88 (1648.0) 44.00 (1117.6)(2) 0.50, 0.75, 1.00 (2) 12.7, 19.1, 25.4 2 Three-phase 400A 20.13 (511.3) 61.00 (1549.4) 11.88 (301.8) 12.00 (304.8) 64.88 (1648.0) 44.00 (1117.6)(4) 2.00, 2.50, 3.00, 3.50, 4.00 (4) 50.8, 63.5, 76.2, 88.9, 101.6 2 Three-phase 800A 25.13 (638.3) 61.00 (1549.4) 11.88 (301.8) 17.00 (431.8) 64.88 (1648.0) 44.00 (1117.6)(4) 2.00, 2.50, 3.00, 3.50, 4.00 (4) 50.8, 63.5, 76.2, 88.9, 101.6 2 Volume 1—Residential and Light Commercial CA08100002E—September 2012 www.eaton.com V1-T5-113 5 5.11Metering Products Group Metering Approximate Dimensions in Inches (mm) Main Circuit Breakers, Terminal Boxes and Pull Boxes Top Feed Fusible Switch Bottom Feed Fusible Switch and Combination Fusible Switch with Pull Box Bolted Pressure Switch EUSERC Main Terminal Box C B A E D Main CB, Non-Euserc Terminal Box and Pullboxes F C 17.00 (431.8) A E B D Top Feed Switch (No Knockouts) F Bottom Feed Switch and Combination Switch/Pullbox A E B D C 17.00 (431.8) F D BE A 25.00 (635.0) F C A B C V1-T5-114 Volume 1—Residential and Light Commercial CA08100002E—September 2012 www.eaton.com 5 5.11 Metering Products Group Metering Approximate Dimensions in Inches (mm) Knockout 1 Knockout 2 Knockout 3 Knockout 4 Knockout 5 Knockout 6 Knockout 7 Knockout 8 .875 .020 .169+.003 –.000 Diameter 5 Hole .175 .010 Stamped ID Mark 5.375 .010 3.500 .010 2.880 .010 KO (44) KO (1) 12.375 .010 3.010 .010 2.880 .030 2-1/2”, 3”, 3-1/2”, 4” KO 1 Knockout Required 1/2”Knockout 1 Required Per 50-1827-1 .080 .0202.500 .020 .310 .030 Diameter Paint Hole.080 .020 .438 .010 .800 .030 .625 .010 6.500 Outside .010CL 8.00 2 Knockouts for 1/2”, 3/4” or 1” Conduit 4 Knockouts for 2-1/2”, 3”, 3-1/2” or 4” Conduit .281 Diameter Knockout 1 Required A .45 3.25 2.50 1.75 4.25 .16 22.54 11.62 10.382.50 3.75 1.93 .61 19.40 8.00 4.00 11.19 2.125 .020 6.000 .010 6.000 .010 6.000 .010 6.000 .010 6.000 .010 6.000 .010 6.000 .010 6.000 .010 6.000 .010 3/4”, 1”, 1-1/4”, 1-1/2” Knockout Per A50-26319 1 Knockout Required 32.120 .020 3”, 3-1/2”, 4”, 5” Knockout Per A50-26327 5 Knockouts Required .380 .020 2.750 .010 2.750 .010 2.750 .010 4.000 .020 7.500 .020 2.125 .020 1.440 .020 .169 .002 Diameter 5 Holes Required at ”X” 1.500 .020 .130 .030 .125 .030 4.440 .020 8.00 22.54 11.62 10.382.50 19.40 8.00 4.00 3.75 1.93 .61 11.19 .45 3.25 2.50 1.75 4.25 2 Knockouts for 1/2”, 3/4” or 1” Conduit 4 Knockouts for 2-1/2”, 3”, 3-1/2” or 4” Conduit .281 Diameter Knockout 1 Required .16 B 6.000 .020 KO (10) KO (10) 5.000 .020 .150 .020 Typ.3.250 .020 3.000 .020 .150 .020 Typ. 6.120 .020 6.850 .020 7.000 +.000 –.030 .780 .020 Typ. .200 .020 Typ. KO (10) .150 .020 Typ. KO (10) KO (10) 6.000 .020 6.000 .020 6.000 .020 .250 Ref. .150 .020 Typ. 4.000 .020 4.250 .020 .250 Ref. .220 Dia. Paint Hole 10.120 .020 10.850 .020 11.000 +.000 -.030 .200 .020 Typ..780 .020 Typ. 7.250 .020 7.250 .020 7.250 .020 5.125 .020 .350 Ref. .150 .020 Typ. 4.000 .020 4.250 .020 .350 Ref. .220 Dia. Paint Hole .150 .020 Typ. KO (11) KO (11) KO (11) KO (11) 10.140 .020 10.850 .020 11.000 +.000 –.030 .120 .020 Typ..685 .020 Typ. 4 Knockouts for 2-1/2", 3", 3-1/2" or 4" Conduit 8.00 4.00 8.00 24.38 11.251.75 2.13 15.38 3.75 16.63 27.13 2.50 3.63 0.50 4.75 3.13 2.50 1.50 4.25 1.75 .281 Dia. Knockout 1 Required 2 Knockouts for 1/2", 3/4", or 1" Conduit 2 Knockouts for 1/2", 3/4", or 1" Conduit Detail Bill of Material Page 1 of 1 Project Name: STONE QUARRY Negotiation No: SY880507X4K1 General Order No: Alternate No: 0003 Item No. Qty Product Description 1 Panelboards 42Circuits, 225A, Series Rated, 208Y/120V 3Ph 4W, Aluminum Bus, 65k AIC, 225A, MLO-Upstream ED[Top Fed], Surface Mounted Catalog No P1A225LT42AH01 Designation LAUNDRY Qty List of Materials 1 225A, MLO-Upstream ED 1 45A, 2P BAB Branch Breaker 16 15A, 1P BAB Branch Breaker 15 20A, 1P BAB Branch Breaker 7 1P BAB Branch Provision Only 1 15A, 2P BAB Branch Breaker 1 Std. Bolted Al Ground Bar (Al/Cu Cable) 1 Panel Nameplate - White with Black Letters 1 Type 1 Enclosure: EZB2042R 1 EZ Trim, Door in Door, Concealed Hardware: EZT2042S Item No. Qty Product Description 1 Panelboards 42Circuits, 400A, Series Rated, 208Y/120V 3Ph 4W, Aluminum Bus, 65k AIC, 400A, MLO-Upstream HKD[Top Fed], Surface Mounted Catalog No P3A400LT50AH01 Designation MDP Qty List of Materials 1 400A, MLO-Upstream HKD 1 Shunt Trip (48-127Vac) 1 Auxiliary Switch, (1A/1B) 1 200A, 3P ED Branch Breaker 18 20A, 1P BAB Branch Breaker 5 15A, 2P BAB Branch Breaker 8 1P BAB Branch Provision Only 1 150A, 3P ED Branch Breaker 1 Std. Bolted Al Ground Bar (Al/Cu Cable) 1 Panel Nameplate - White with Black Letters 1 Type 1 Enclosure: EZB2090R 1 EZ Trim, Door in Door, Concealed Hardware: EZT2090S Eaton Selling Policy 25-000 applies. All orders must be released for manufacture within 90 days of date of order entry. If approval drawings are required, drawings must be returned approved for release within 60 days of mailing. If drawings are not returned accordingly, and/or if shipment is delayed for any reason, the price of the order will increase by 1.0% per month or fraction there of for the time the shipment is delayed. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 Main Lugs Only 225A BAB2045 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB2015 BAB1015 BAB1015 BAB1015 BAB1015 BAB1015 BAB1015 BAB1015 BAB1015 BAB1015 BAB1015 BAB1015 BAB1015 BAB1015 BAB1015 BAB1015 BAB1015 Blank Cover 2 inches PROV PROV PROV PROV PROV PROV PROV General Information (Section 1 of 1) Service Voltage:208Y/120V 3Ph 4W Enclosure:Type 1 Bus Rating & Type:225A Aluminum Neutral Rating:225A Ground Bar:Std. Bolted Aluminum, Al or Cu cable S.C. Rating:65k A.I.C. Series Rated Main Device Type:MLO-Upstream ED -Top Cable Entry Main Terminals:Mechanical -(1) #6-300 kcmil (Cu/Al) Neutral Terminals:Mechanical -(1) #6-300 kcmil (Cu/Al) Box Catalog No.:EZB2042R Trim:EZ Trim, Door in Door, Concealed Hardware (EZT2042S) Surface Mounted Box Dimensions:42.00" [1066.8mm]H x 20.00" [1066.8mm]W x 5.75" [146.1mm]D Min. Gutter Size:Top = 5.5" [139.7mm] Bottom = 5.5" [139.7mm] Left = 6.0" [152.4mm] Right = 6.0" [152.4mm] Panel ID Nameplate:(1) LAUNDRY Type:Plastic, adhesive-backed (2) 208Y/120V 3Ph 4W Color:White with Black Letters (3) NEC Lighting & Appliance, UL CTL ***Non-Interchangeable Main Device*** Trim Lock: Standard Lock & Key (Keyed WEM2) Circuit Directory: Plastic Sleeve with Card Branch Devices Qty Poles Trip Frame Amps kAIC 1 2 45 BAB 100 65 16 1 15 BAB 100 65 1 2 15 BAB 100 65 15 1 20 BAB 100 65 7 1 PROV Device Modifications: Ref #Description Notes: NEG-ALT Number PREPARED BY DATE APPROVED BY DATE VERSION REVISION DWG SIZE JOB NAME DESIGNATION TYPE G.O. DRAWING TYPE ITEM SHEET The information on this document is created by Eaton Corporation. It is disclosed in confidence and it is only to be used for the purpose in which it is supplied. SY880507X4K1-0003 PETER ANDRELLA 12/17/2014 1.0.0.1 0 A Eaton STONE QUARRY LAUNDRY PRL1a Customer Approval 1 of 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 Main Lugs Only 400A Neutral BAB1020 BAB1020 PROVBAB1 PROVBAB1 PROVBAB1 PROVBAB1 PROVBAB1 PROVBAB1 PROVBAB1 PROVBAB1 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB1020 BAB2015 BAB2015BAB2015 BAB2015BAB2015 ED3200 200A ED3150 150A Bus Cover 15X General Information (Section 1 of 1) Service Voltage:208Y/120V 3Ph 4W Enclosure:Type 1 Bus Rating & Type:400A Aluminum Neutral Rating:400A Ground Bar:Std. Bolted Aluminum, Al or Cu cable S.C. Rating:65k A.I.C. Series Rated Main Device Type:MLO-Upstream HKD -Top Cable Entry Main Terminals:Mechanical -(2) #4-500 kcmil (Cu/Al) Neutral Terminals:Mechanical -(2) #4-500 kcmil (Cu/Al) Box Catalog No.:EZB2090R Trim:EZ Trim, Door in Door, Concealed Hardware (EZT2090S) Surface Mounted Box Dimensions:90.00" [2286.0mm]H x 20.00" [2286.0mm]W x 5.75" [146.1mm]D Min. Gutter Size:Top = 5.5" [139.7mm] Bottom = 5.5" [139.7mm] Left = 4" [101.6mm] Right = 4" [101.6mm] Panel ID Nameplate:(1) MDP Type:Plastic, adhesive-backed (2) 208Y/120V 3Ph 4W Color:White with Black Letters (3) NEC Lighting & Appliance, UL CTL Trim Lock: Standard Lock & Key (Keyed WEM2) Circuit Directory: Plastic Sleeve with Card Branch Devices Qty Poles Trip Frame Amps kAIC 18 1 20 BAB 100 65 1 3 150 ED 225 65 1 3 200 ED 225 65 8 1 PROVBAB1 5 2 15 BAB 100 65 Device Modifications: Ref #Description SNT1RP08K Shunt Trip (48-127Vac) Ckt #:37 A1X1PK Auxiliary Switch, (1A/1B) Ckt #:37 Notes: NEG-ALT Number PREPARED BY DATE APPROVED BY DATE VERSION REVISION DWG SIZE JOB NAME DESIGNATION TYPE G.O. DRAWING TYPE ITEM SHEET The information on this document is created by Eaton Corporation. It is disclosed in confidence and it is only to be used for the purpose in which it is supplied. SY880507X4K1-0003 PETER ANDRELLA 12/17/2014 1.0.0.1 0 A Eaton STONE QUARRY MDP PRL3a Customer Approval 1 of 1 Volume 2—Commercial Distribution CA08100003E—April 2014 www.eaton.com V2-T3-7 3 3.3Panelboards and Lighting Control Pow-R-Line C Panelboards Pow-R-Line C Panelboards Product Description Lighting and Distribution Panelboards Eaton’s assembled panelboards are designed for sequence phase connection of branch circuit devices. This allows complete flexibility of circuit arrangement (single-, two- or three-pole) to allow balance of the electrical load on each phase. Sturdy, rigid chassis assembly ensures accurate alignment of interior with panel front; prevents flexing and minimizes possibility of loosening or damage to current carrying parts during and after installation. Four-point in-and-out adjustment of panel interior is provided to meet critical depth dimensions on flush installations. This compensates for possible misalignment of box at installation. Main lugs are mechanical solderless type and approved for copper or aluminum conductors. Enclosures Boxes are code-gauge galvanized steel, which include a painted box finished in ANSI-61 light gray to match the trim. Standard panelboard cabinets are designed for indoor use. Alternate types are available for indoor and special purpose applications. All enclosures are furnished in accordance with Underwriters Laboratories standards and include wiring gutters with proper wire bending space. Special cabinets can be provided at an additional charge. The box dimensions shown are inside dimensions. For outside dimensions, add 1/4-inch (6.4 mm). Standard panelboard boxes are supplied without knockouts (blank endwalls). Fronts Fronts (trims) for all panelboards are made of code-gauge steel and have a high durability ANSI-61 light gray finish applied by a baked- on polyester powder coating paint system. The fronts for lighting and appliance branch circuit panelboards and small power distribution panelboards include a door with rounded corners and concealed hinges. A flush-type latch and lock assembly is included. All locks are keyed alike. These trims are available in both surface- and flush- mounted designs. EZ Trim Features Standard Door-in-Door with No Exposed Hardware or Sharp Edges (no Tools are Required for Installation) The Three-Piece Trim for Larger Power Distribution Panelboards Provides for Easy Handling and Installation Fronts for power distribution panelboards utilize a unique breaker front cover design in which each device has a dedicated bolt-on steel cover. The individual covers form a single deadfront for the panelboard that is used in conjunction with two wiring gutter covers to complete the trim. A door is not finished as part of the standard offering on these panelboards but can be provided, for an additional charge, using a deeper than standard box. V2-T3-8 Volume 2—Commercial Distribution CA08100003E—April 2014 www.eaton.com 3 3.3 Panelboards and Lighting Control Pow-R-Line C Panelboards Application Description Panelboard Selection Factors In selecting a panelboard, the following factors must be considered: ●Service (voltage and frequency) ●Interrupting capacity (fully or series rated) ●Ampere rating of main ●Ampere ratings of branches ●Environment Panelboard Short-Circuit Rating The short-circuit rating of Eaton’s assembled panelboards are test verified by, and listed with, Underwriters Laboratories (UL). Generally, these ratings are that of the lowest interrupting rated device in the panel. Certain exceptions to this rule exist where branch devices have been UL tested in combination with specific main devices having a higher interrupting rating. Where these defined main devices and branch breaker combinations are utilized, the series short-circuit rating of the assembled panelboard will be the same as the tested rating of the approved rated main device in series with the branches. Available main and branch breaker combinations are tabulated starting on Page V2-T3-16. All combinations shown are UL tested and listed. These series ratings apply to panels having main devices, or main lug only panelboards fed remotely by the device listed in the series ratings chart as the main, for which UL listed tests were conducted. Service Entrance Equipment The National Electrical Code (NEC) requires that: ●A panel used as service entrance equipment must be located near the point where the supply conductors enter the building ●A panelboard having main lugs only shall have a maximum of six service disconnects to de-energize the entire panelboard from the supply conductors. Where more than six disconnects are required, a main service disconnect must be provided ●A disconnectable electrical bond must be provided between the neutral and ground ●A service entrance type UL label must be factory installed ●Ground fault protection of equipment shall be provided for each service disconnect rated 1000A or more if the electrical service is a solidly grounded wye system of more than 150V to ground, but not exceeding 600V phase-to-phase Note: Service entrance panels must be identified as such on the order. Panelboard Standards In 2008, both the National Electrical Code (Article 408) and UL 67 were updated to remove the mandated 42-circuit limitation. Eaton offers panelboards with more than 42 circuits for those jurisdictions that have adopted the 2008 NEC or later. For jurisdictions that have| not adopted the 2008 or later version of the National Electrical Code, the 42-circuit limitation for Lighting and Appliance Branch Panelboards remains in place. Check with your local code officials to determine specific jurisdiction status. Panelboard Installation NEC requires that the operating handle of the topmost mounted device be no more than 6 feet 7 inches (2006.6 mm) above the finished floor and should be installed per NEC and manufacturer’s instructions. Additional boxes and fronts are required when the components required for one panelboard exceed the standard box dimensions. Multi-Section Panelboards When two or more separate enclosures are required, separate fronts for each box are standard. A common front can be furnished at additional charge. Interconnecting Multi- Section Panelboards When a panelboard, for connection to one feeder, must be furnished in more than one section (Box), each section must be furnished with main bus and terminals of the same rating, unless a main overcurrent device is provided in each section. Sub-feed or through-feed provisions must also be included (and priced) to provide connection capability to the second section. Note: Sub-feed or through-feed lugs cannot be used on any panelboard that is not protected by a single main overcurrent device either in the panelboard or immediately upstream, i.e., service entrance panelboards with main lugs only using the six disconnect rule. Volume 2—Commercial Distribution CA08100003E—April 2014 www.eaton.com V2-T3-9 3 3.3Panelboards and Lighting Control Pow-R-Line C Panelboards Sub-Feed Lugs Sub-feed lugs (see figure below) are one means of interconnecting multi-section panels. The sub-feed (second set of) lugs are mounted directly beside the main lugs. These are required in each section except the last panel in the lineup. The feeder cables are brought into the wiring gutter of the first section and connected to the main lugs. Another set of the same size cables are connected to the sub-feed lugs (Section 1) and are carried over to the main lugs of the adjacent panel. Cross connection cables are not furnished by Eaton. Sub-feed lugs are only available on main lug only panels. Note: Sub-feed lugs may not be used on main lug only (six disconnect rule) service entrance panels. Sub-Feed Lugs Through-Feed Lugs Through-feed lugs (see figure below) are another method to interconnect multi-section panelboards. The incoming feeder cables are connected to the main lugs or main breaker at the bottom of panel (Section 1). Another set of lugs (through-feed) are located at the opposite end of the main bus. The interconnecting cables are connected to the through- feed lugs in Section 1 and are carried over to the main lugs in Section 2. The connection arrangement could be reversed, i.e., main lugs at top; through-feed lugs at bottom end of panel. Cross cables are not furnished by Eaton. Note: Through-feed lugs may not be used on main lug only (six disconnect rule) service entrance panels. Through-Feed Lugs Box Box Conduit Neutral Neutral PanelPanelSection 1 Section 2 Section 1 Section 2 Box Box Conduit Neutral PanelPanelNeutral Main Lugs Thru Feed Lugs Main Lugs Cross Cables Incoming Feeder Cables Multiple Section Panelboard—Flush Mounted Shown below is the standard method for flush mounting multiple section lighting and distribution panelboards using standard flush trims. Multiple Section Panelboard Flush Mounted— Dimensions in Inches (mm) Overcurrent Protection The following requirements will be found in the NEC: Each lighting and appliance branch circuit panelboard shall be individually protected on the supply side by not more than two main circuit breakers or two sets of fuses having a combined rating not greater than that on the panelboard. Contractor to Mount Boxes 1-1/2-inch (38.1 mm) Apart to Allow for 3/4-inch (19.1 mm) Extension on Both Flush Trims Two Section Panelboard (Flush Mounting) Flush Trim Extends 3/4-inch (19.1 mm) Beyond Outside of Box on All Four Sides Outside Edge of BoxTrim Wall WallTrim Trim Conduit Nipple for Cross Wiring by Contractor 3/4 (19.1) 3/4 (19.1) 1 1/2 (38.1) Top Section View 3/4 (19.1) 3/4 (19.1) 3/4 (19.1) 3/4 (19.1) 3/4 (19.1) 3/4 (19.1) 3/4 (19.1) 3/4 (19.1) V2-T3-10 Volume 2—Commercial Distribution CA08100003E—April 2014 www.eaton.com 3 3.3 Panelboards and Lighting Control Pow-R-Line C Panelboards Branch Circuit Loading for Lighting Panels The size of mains and branches should be selected based on the following: ●Motor circuits: NEC Article 430 ●Diversity factor ●Provision for future loading Exception Number 1: Individual protection for a lighting panelboard is not required when the panelboard feeder has overcurrent protection not greater than that of the panelboard. Exception Number 2: For existing installations, individual protection for lighting panelboards is not required where such panelboards are used as service equipment in supplying an individual residential occupancy and where any bus supplying 15 or 20A circuits is protected on the supply side by an overcurrent device. Ambient Temperatures The primary function of an overcurrent device is to protect the conductor and its insulation against overheating. In selecting the size of the devices and conductors, consideration should be given to the ambient temperature surrounding the conductors within and external to the panelboard. Cumulative heating within the panelboard may cause premature operation of the overcurrent protective devices. Underwriters Laboratories test procedures are based, in part, on 80% loading of panelboard branch circuit devices. The NEC limits the loading of overcurrent devices in panelboards to 80% of rating where in normal operation the load will continue for three hours or more. Further derating may be required, depending on such factors as ambient temperature, duty cycle, frequency or altitude. Exception: There is one exception to this rule in both UL and NEC. It applies to assemblies and overcurrent devices that have been listed for continuous duty at 100% of its rating. Special Conditions Standard panelboards, assembled with standard components, are adequate for most applications. However, special consideration should be given to those required for application under special conditions such as: ●Excessive vibration or shock ●Frequencies above 60 cycles ●Altitudes above 6600 feet (2011.7m) ●Damp environment (possible fungus growth) ●Compliance with federal, state and municipal electrical codes and standards Seismic Considerations The Uniform Building Code® and the International Building Code, as well as local and state building codes, place an emphasis on seismic building design requirements. Electrical distribution systems are treated as attachments to the building and therefore, fall into this category. All Eaton panelboards are seismic qualified at the highest possible level, and have been tested in accordance with ANSI C37.81. This standard quantifies actual earthquake conditions, as well as equipment seismic capability. Harmonic Currents Standard panelboard neutrals are rated for 100% of the panelboard current. However, since harmonic currents can cause overheated neutrals, an option is provided for neutrals to be rated at 200% (1200A maximum neutral for 600A main bus) of the panelboard phase current. Panelboards with the 200% rated neutral are UL listed as suitable for use with non- linear loads. Prior to specifying the 200% rated neutral, Eaton recommends a harmonic survey be conducted of the distribution system, be it new or existing. Surge Protective Devices The quality of power feeding sensitive electronic loads is critical to the reliable operation of any facility. In modern offices, hospitals, and manufacturing facilities, the most frequent causes of microprocessor-based equipment downtime and damage are voltage transients and electrical noise. Electrical loads and microprocessor-based equipment are highly susceptible to both high and low energy transients. High energy transients include lightning induced surges and power company switching. These high energy transients can destroy components instantly. More frequently the electrical system experiences low energy transients and high frequency noise. The effects of continual low energy transients and high frequency noise can cause erratic equipment performance or sudden failure of electronic circuit board components. Eaton can provide protective and diagnostic systems integral to panelboards. The surge protective device (SPD) is integrated into the panelboards using a “zero lead length” direct bus bar connection. Pow-R-Line 4 The SPD protects sensitive electronic equipment from the damaging effects of high and low energy transients, as well as high frequency noise. Standards and Certifications Eaton’s panelboards are designed to meet the following applicable industry standards, except where noted: ●Underwriters Laboratories: ●Panelboards: UL 67 ●Cabinets and Boxes: UL 50 Note: Only panelboards containing UL listed devices can be UL labeled. ●National Electrical Code ●NEMA Standards: PB 1 ●Federal Specification W-P-115c: ●Circuit Breakers— Type I Class I ●Fusible Switch— Type II Class I Volume 2—Commercial Distribution CA08100003E—April 2014 www.eaton.com V2-T3-11 3 3.3Panelboards and Lighting Control Pow-R-Line C Panelboards Technical Data and Specifications Panelboard Selection Guide Note 1 Fixed mounted only. Maximum Voltage Rating Maximum Main Rating (Amperes) AC Interrupting Capacity rms Symmetrical Amperes (kA) Panelboard Type Device Type AC DC MLO Main Device Branch Circuits Ampere Range Sub-Feed Breaker Maximum Amperes Fully Rated Series Rated PRL1a Breaker 240 — 400 400 15–100 400 10–22 22–100 PRL1R Breaker 240 — 225 225 15–100 — 10–22 22–100 PRL1aF Fusible 240 — 400 400 15–30 400 200 — PRL1a-LX Breaker 240 — 225 225 15–100 — 10–22 22–100 PRL2a Breaker 240 250 400 400 15–100 400 65 65–200 Breaker 480Y/277 250 400 400 15–100 400 14 22–150 PRL2R Breaker 240 — 225 225 15–100 — 10–22 22–200 Breaker 480Y/277 — 225 225 15–100 — 14 22–100 PRL2aF Fusible 480Y/277 — 400 400 15–30 400 200 — PRL2a-LX Breaker 240 250 225 225 15–100 — 65 65–200 Breaker 480Y/277 250 225 225 15–100 — 14 22–150 PRL3a Breaker 240 250 800 600 15–225 600 10–200 22–200 Breaker 480 250 800 600 15–225 600 14–100 22–150 Breaker 600 250 800 600 15–225 600 14–35 — PRL3E Breaker 240 250 600 600 15–125 400 25–100 100–200 Breaker 480Y/277 250 600 600 15–125 400 18–65 65–100 Breaker 480 250 600 600 15–125 400 18–65 65–100 PRL4B Breaker 240 600 1200 1200 15–1200 — 10–200 22–200 Breaker 480 600 1200 1200 15–1200 — 14–200 22–150 Breaker 600 600 1200 1200 15–1200 — 14–200 — PRL4D Breaker 240 — 1200 1200 1 600 —65–200 — Breaker 480 — 1200 1200 1 600 —35–100 — Breaker 600 — 1200 1200 1 600 —18–50 — PRL4F Fusible 240 250 1200 1200 30–1200 —100–200 — Fusible 600 250 1200 1200 30–1200 —100–200 — PRL5P Breaker 240 250 1200 1200 15–1200 —10–200 22–200 Breaker 480 250 1200 1200 15–1200 —14–200 22–150 Breaker 600 250 1200 1200 15–1200 —14–200 — PRC100 PRC25 Breaker 240 — 400 400 15–225 —10–65 22–100 Breaker 480Y/277 — 400 400 15–225 —14 65–100 Elevator Control Fusible 240 — 800 800 15–200 —200 — Fusible 480Y/277 — 800 800 15–200 —200 — Fusible 480 — 800 800 15–200 —200 — Terminal Wire Ranges, Pressure-Type Al/Cu Terminals Except as Noted Note: All terminal sizes are based on wire ampacities corresponding to those shown in NEC Table 310.16 under the 75°C insulation columns (75°C wire). The use of smaller size, (in circular mills), regardless of insulation temperature rating, is not permitted. Where copper-aluminum terminals are supplied on designated panelboard types, best results are obtained if a suitable joint compound is applied when aluminum conductors are used. Check Eaton’s standard terminal sizes versus customer requirements. In particular, 400 and 800A breakers often require nonstandard lugs. Optional 750 kcmil mechanical screw-type terminals are available upon request. Panelboard dimensions may be affected, refer to Eaton. Volume 2—Commercial Distribution CA08100003E—April 2014 www.eaton.com V2-T3-13 3 3.3Panelboards and Lighting Control Pow-R-Line C Panelboards Standard Circuit Breaker Terminals Breaker Type Ampere Rating Wire Range BAB, QBHW, BABRSP, HQP, QPHW 15–70 #14–#4 90–100 #8–1/0 EDB, EDS, ED, EDH, EDC 100–225 #4–4/0 or #6–300 kcmil EGB, EGE, EGS, EGH 15–50 #14–3/0 AL/CU 60–125 #6–3/0 AL/CU EHD, FDB, FD, HFD, FDC, HFDDC 2 15–100 #14–1/0 125–225 #4–4/0 FCL 15–100 #14–1/0 GHB, HGHB, GHQ, GHQRSP 15–20 #14–#10 25–100 #10–1/0 EGB, EGS, EGH 15–50 #14–1/0 60–125 #6–2/0 JD, HJD, JDC, HJDDC 2 70–250 #4–350 kcmil DK 250–350 250–500 kcmil 400 (2) 3/0–250 kcmil or (1) 3/0–500 kcmil KD, HKD, KDC, HKDDC, 2 CKD, CHKD 225 (1) #3–350 kcmil 350 (2) 3/0–250 kcmil or 400 (2) 3/0–250 kcmil or (1) 3/0–500 kcmil LHH 150–400 #2–500 kcmil 150–400 (2) #2–500 kcmil 150–400 (1) 500–750 kcmil LGE, LGH, LGC, LGU, LHH 1 250–400 (1) #2–500 kcmil 500–600 (2) #2–500 kcmil LD, HLD, LDC, HLDDC 2 CLD, CHLD 300–500 (2) 250–350 kcmil 600 (2) 400–500 kcmil MDL, HMDL, HMDLDC 2 CMDL, CHMDL 400–600 (2) #1–500 kcmil 700–800 (3) 3/0–400 kcmil ND, HND, CND, CHND, NDC, CNDC 800–1000 (3) 3/0–400 kcmil 1200 (4) 4/0–500 kcmil LCL 125–225 (1) #6–350 kcmil 250–400 (1) #4–250 kcmil and (1) 3/0–600 kcmil FB-P 15–100 #14–1/0 LA-P 70–225 #6–350 kcmil 250–400 (1) #4–250 kcmil and (1) 3/0–600 kcmil NB-P, NBDC 2 300–700 (2) #1–500 kcmil 800 (3) 3/0–400 kcmil FDPW Switch Terminals Elevator Control Panel Feeder Terminals Notes 1 LHH is 400A maximum. 2 Suitable for DC applications only. Ampere Rating Wire Range 30 #14–1/0 60 #14–1/0 100 #14–1/0 200 #4–300 kcmil 400 250–750 kcmil or (2) 3/0–250 kcmil 600 (2) #4–600 kcmil or (4) 3/0–250 kcmil 800 (3) 250–750 kcmil or (6) 3/0–250 kcmil 1200 (4) 250–750 kcmil or (8) 3/0–250 kcmil Ampere Rating Wire Range 30 #14–1/0 60 #14–1/0 100 #14–1/0 200 #4–300 kcmil Detail Bill of Material Page 1 of 1 Project Name: STONE QUARRY Negotiation No: SY880507X4K1 General Order No: Alternate No: 0003 Item No. Qty Product Description 1 Safety Switches Safety Switches Catalog No DH324FGK Designation ELEV Qty List of Materials 1 Auxiliary Contact Kit : 1NO/1NC - DS200EK1 (Field Installed) 1 Heavy Duty Switch - Fusible, 3-Pole, 240 VAC, 200 A, NEMA 1 Item No. Qty Product Description 1 Safety Switches Safety Switches Catalog No DG221NGB Designation ELEV Qty List of Materials 1 General Duty Switch - Fusible, 3-Wire, 240 VAC, 30 A, NEMA 1 Eaton Selling Policy 25-000 applies. All orders must be released for manufacture within 90 days of date of order entry. If approval drawings are required, drawings must be returned approved for release within 60 days of mailing. If drawings are not returned accordingly, and/or if shipment is delayed for any reason, the price of the order will increase by 1.0% per month or fraction there of for the time the shipment is delayed. Safety Switch General Information Global Specifications System Voltage 240 VAC Switch Type Single Throw -Heavy Duty Poles/Blades 3-Pole Amperage 200 Protection Fusible with No Neutral Enclosure Type NEMA 1 Fuse Clips Standard Switch Lugs Standard Fungus Proof Treatment N Lock-On Provision N Fuse Pullers N Control Pole N Ground Lugs N 316 Stainless N Stainless Mechanism N Mill Duty N Nameplate Field Installed Kits QUANTITY DESCRIPTION 1 Auxiliary Contact Kit : 1NO/1NC -DS200EK1 (Field Installed) Safety Switch Catalog No. DH324FGK NEG-ALT Number PREPARED BY DATE APPROVED BY DATE VERSION REVISION DWG SIZE JOB NAME DESIGNATION TYPE G.O. DRAWING TYPE ITEM SHEET The information on this document is created by Eaton Corporation. It is disclosed in confidence and it is only to be used for the purpose in which it is supplied. SY880507X4K1-0003 PETER ANDRELLA 12/17/2014 1.0.0.1 0 A Eaton STONE QUARRY ELEV Safety Switch General Information Customer Appr. 1 of 1 GO/NEG-Alt-Date: Job Name: Item Number: Catalog Number: Designation: SY880507X4K1-0003-12/17/2014 STONE QUARRY DH324FGK ELEV Safety Switch General Information Global Specifications System Voltage 240 VAC Switch Type Single Throw -General Duty Poles/Blades 2-Pole Amperage 30 Protection Fusible with Neutral Enclosure Type NEMA 1 Fuse Clips Standard Switch Lugs Standard Fungus Proof Treatment N Lock-On Provision N Fuse Pullers N Control Pole N Ground Lugs N 316 Stainless N Stainless Mechanism N Mill Duty N Nameplate Safety Switch Catalog No. DG221NGB NEG-ALT Number PREPARED BY DATE APPROVED BY DATE VERSION REVISION DWG SIZE JOB NAME DESIGNATION TYPE G.O. DRAWING TYPE ITEM SHEET The information on this document is created by Eaton Corporation. It is disclosed in confidence and it is only to be used for the purpose in which it is supplied. SY880507X4K1-0003 PETER ANDRELLA 12/17/2014 1.0.0.1 0 A Eaton STONE QUARRY ELEV Safety Switch General Information Customer Appr. 1 of 1 Date PDF Generated:9/28/2012 Page: 1 of 1 GO/NEG-Alt-Date: Job Name: Item Number: Catalog Number: Designation: SY880507X4K1-0003-12/17/2014 STONE QUARRY DG221NGB ELEV Catalog Number Selection Safety Switch Notes 1 Always verify the number of poles and wires required since catalog numbers may appear in multiple tables. 2 See Pages V2-T1-17 through V2-T1-20 for additional Flex Center options. 3 Effective August 2003, 30–100A window switches are replaced by a full view window that allows blade position verification and blown fuse indication. See Page V2-T1-37 for catalog numbers. This table is intended for use in breaking down existing catalog numbers. It is not intended for building new catalog numbers. Series K = Design all general-duty switches above 200A and all heavy-duty switches incorporate K-Series switch design features listed below B = Design general-duty 30–100A H = General-duty double-throw switch (compact design 30–100A)Fusible/Non-Fusible or Neutral F = Fusible without neutral U = Non-fusible N = Fusible with neutral NEMA Enclosure Ratings G = NEMA 1 R = NEMA 3R D = NEMA 12 or 12/3R P = NEMA 4 (painted steel) W = NEMA 4X (corrosion-resistant (304 Grade stainless steel) C = NEMA 4X non-metallic (for Type DH) X = NEMA 7/9 (for Type DS) X = NEMA 4X non-metallic (for Type DR) Switch Type DP = General-duty/plug fuse DG = General-duty/cartridge fuse DH = Heavy-duty DT = Double-throw DR = Rotary switch DS = Classified location with DS interior Voltage 1 = 120 Vac 2 = 240 Vac 6 = 600 Vac Ampere Rating 1 = 30A 2 = 60A 3 = 100A 4 = 200A 5 = 400A 6 = 600A 7 = 800A 8 = 1200A Options 2 W = Upper viewing window 3 LW = Lower viewing window 3 X = EnviroLine stainless (enclosure and mechanism) GCL = Mill-duty Poles/Blades 1 = 1-pole 2 = 2-pole 3 = 3-pole 4 = 4-pole 6 = 6-pole DH 3 6 1 N D K LW Quick Connect Double-Throw Notes 1 When upper and lower switches are the same, the switch configuration is consolidated in one letter (e.g., “U” not “UU”). Also, a switch with a neutral will have either a solid neutral or a switched neutral, not both. Lastly, a switched neutral pole is never fused. 2 This field is only used when a switch is completely non-fused. Switch Type DT = Heavy-duty double-throw DH = Heavy-duty single-throw Poles 2 = Two-pole 3 = Three-pole 4 = Four-pole Maximum Voltage 2 = 240 Vac 6 = 600 Vac Switch Ampacity 3 = 100A 4 = 200A 5 = 400A 6 = 600A 7 = 800A Upper Switch 1 U = Unfused F = Fusible N = Fusible with solid neutral SN = Fusible with switched neutral Series K= K DT 3 6 5 N U R K LC Enclosure G = NEMA 1 R= NEMA 3R Receptacle Type LC = Cam-Lok LCR = Cam-Lok reverse pin LP =Posi-Lok LPR = Posi-Lok reverse pin Neutral Blank = No neutral or incl. with switch designation N = Solid neutral SN = Switched neutral Lower Switch 2 U = Unfused F = Fusible N = Fusible with solid neutral SN = Fusible with switched neutral V2-T1-24 Volume 2—Commercial Distribution CA08100003E—May 2012 www.eaton.com 1 1.1 Switching Devices Safety Switches Cartridge Fuse General-Duty Safety Switch General Duty Product Description ●30–600A ●Suitable for service entrance applications unless otherwise noted ●Fusible and non-fusible switches are 100% load break and 100% load make rated ●The continuous load current of fusible switches is not to exceed 80% of the rating of fuses employed in other than motor circuits. Non-fusible switches are 100% fully rated ●200–600A features K-Series design ●Horsepower rated ●Fusible and non-fusible switches. Single-pole S/N through four-wire; 120/240, and 240 Vac ●With Class R fuses, switches may be used on systems capable of delivering 100,000A rms symmetrical Note: Plug fuse switches are not service entrance rated. 120/240 Vac General-Duty, Fusible, Single-Throw ●30–600A ●Suitable for service entrance applications unless otherwise noted ●Horsepower rated ●Bolt-on hub provision. Provided for general-duty switches in a NEMA 3R enclosure. See Page V2-T1- 21 for selection ●200–600A switches incorporate K-Series design Non-Fusible Switches The UL listed short-circuit ratings for Eaton’s non-fusible switches are based on the switches being properly protected by overcurrent protective devices. For applications that require a UL listed short-circuit rating of 10,000A rms symmetrical or less, an Eaton non-fusible switch must be properly protected by any overcurrent protective device rated no greater than the ampere rating of the switch. For applications that require a UL listed short-circuit rating of greater than 10,000 rms symmetrical amperes, an Eaton non-fusible switch must be properly protected by the appropriate class and size fusing noted on the switch publication (located on the inside cover). Otherwise, this non-fusible switch must be replaced with an Eaton fusible switch that utilizes the appropriate fusing required. Molded case circuit breaker protection of non- fusible Eaton switches for applications that require a short-circuit rating of greater than 10,000A rms symmetrical has not been evaluated. Refer to the reference tables for typical Eaton fusible switch UL listed short-circuit ratings. Note: Safety switch short-circuit ratings are applicable to AC only. Safety switch l2t and lp values are identical to UL maximum acceptable l2t and lp values for the corresponding class fuse. Application Description For residential and commercial applications. Suitable for light-duty motor circuits and service entrance. Volume 2—Commercial Distribution CA08100003E—May 2012 www.eaton.com V2-T1-25 1 1.1Switching Devices Safety Switches Features, Benefits and Functions General-Duty (Cartridge Fuse) ●Ample wire bending space provides for easier installation ●Visible double-break quick- make, quick-break rotary blade mechanism ●Side opening door on all enclosures ●Mechanically interlocked cover to prevent easy access when the switch is in the ON position ●With Class R fuses, switches may be used on systems capable of delivering 100,000A rms symmetrical ●Clearly visible and accessible neutral where applicable ●Visible ON/OFF indication ●Tangential knockouts on 30–60A designs ●Ample wiring space ●Double padlocking capability on 30–100A ●Triple padlocking capability on 200–600A ●Additional door locking capability ●Bilingual English/Spanish door label on 30–100A ●Tri-lingual nameplates All general-duty switches above 100A and all heavy- duty switches incorporate these K-Series switch design features. ●Two points of contact provide a positive open and close, easier operation, and also help prevent contact burning for longer contact life Visible Double-Break Rotary Blade Mechanism ●Protects against accidental contact with energized parts. Probe holes enable the user to test if the line side is energized without removing the shield. Not typically provided on general-duty switches, but available as a field kit or factory installed Clear Line Shield ●Provide easy removal of fuses Built-In Fuse Pullers (NEMA 12 and 4X 30–200A Only) ●The position (ON or OFF) can be clearly seen from a distance and the length provides for easy operation Clearly Visible Handle ●Personnel safety feature since the large hasp can accommodate up to three 3/8-inch (9.5 mm) shank locks Triple Padlocking Capability ●Cabinet door can be further padlocked at the top and bottom as applicable Additional Locking Capability ●Door cannot be opened when the handle is in the ON position. Front and side operable defeater mechanism provides for user access when necessary on single- throw switches Interlocking Mechanism ●An ample number are provided on the top, bottom and sides of both NEMA Types 1 and 3R enclosures through 200A Tangential Knockouts ●For switches in a NEMA Type 3R, 30–200A. Use a Myers type hub for all others Bolt-On Hub Kits Standards and Certifications ●UL listed File No. E5239 ●Meets UL 98 for enclosed switches and NEMA Std. KS-1 Volume 2—Commercial Distribution CA08100003E—May 2012 www.eaton.com V2-T1-21 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1.1Switching Devices Safety Switches Technical Data and Specifications Standard Lug Capacities Dimensions Approximate Dimensions in Inches (mm) Plate Type Hubs For NEMA 3R enclosures (up to 200A) Catalog number DS900AP adapter kit permits Installation of Group 1 hubs on 200A type general-duty, heavy-duty and double-throw switches. Notes 1 The maximum size aluminum or copper-clad aluminum wire allowable for applications where the conductor enters or leaves the enclosure through the wall opposite its terminal is #1 gauge. Although certain lug capacities are larger than required, only minimum wire bending space is provided per the requirements noted in NEC® Tables 373-6 (a) and (b) for respective ampere ratings. Description Minimum Wire Size Maximum Wire Size Wire Type 30A DP #14 #12 #10 #10 Cu or Al 30A DG #14 #6 Cu/Al 30A DH, DT #14 #2 Cu/Al 60A DG #14 #1/0 Cu/Al 60A DH, DT #14 #2 Cu/Al 100A DG 1 #14 #1/0 Cu/Al 100A DH, DT #14 #1/0 Cu/Al 200A DG, DT #6 250 kcmil Cu/Al 200A DH Type 1 and 3R #6 250 kcmil Cu/Al 200A DH Type 4 and 12 #6 300 kcmil Cu/Al 400A DG, DH, DT (2) #1/0 (1) #1/0 (2) 300 kcmil (1) 750 kcmil Cu/Al or Cu/Al 600A DG, DH, fusible DT (1) #2 (1) #1/0 (1) 600 kcmil (1) 750 kcmil Cu/Al and Cu/Al 600A non-fusible DT (2) #250 (2) 500 kcmil Cu/Al 800A DH (4) #1/0 (4) 750 kcmil Cu/Al 800A DT (3) #250 (3) 500 kcmil Cu/Al 1200A DH, DT (4) #1/0 (4) 750 kcmil Cu/Al Copper-Bodied Lugs 30A Cu #14 #6 Cu 60A Cu #14 #4 Cu 100A Cu #6 #1/0 Cu 200A Cu #6 250 kcmil Cu 400A Cu #1/0 500 kcmil Cu 600A Cu (2) #1/0 (2) 500 kcmil Cu Group 1 General-Duty, Heavy-Duty, Double-Throw Through 100A Group 2 General-Duty, Heavy-Duty, Double-Throw—200A Catalog Number Conduit Size Catalog Number Conduit Size DS075H1 0.75 (19.1)DS200H2 2.00 (50.8) DS100H1 1.00 (25.4)DS250H2 2.50 (63.5) DS125H1 1.25 (31.8)DS300H2 3.00 (76.2) DS150H1 1.50 (38.1)—— DS200H1 2.00 (50.8)—— DS075H1 Volume 2—Commercial Distribution CA08100003E—May 2012 www.eaton.com V2-T1-29 1 1.1Switching Devices Safety Switches Heavy-Duty Safety Switch Heavy-Duty Product Description ●30–1200A ●600 Vac, 600 Vdc maximum ●Horsepower rated ●Fusible and non-fusible switches are 100% load break and 100% load make rated ●The continuous load current of fusible switches is not to exceed 80% of the rating of fuses employed in other than motor circuits. Non-fusible switches are 100% fully rated ●Suitable for service entrance applications unless otherwise noted 240 Vac Heavy-Duty, Fusible, Single-Throw ●30–1200A ●Horsepower rated ●Suitable for service entrance use, except four-pole switches ●For factory modifications, refer to Pages V2-T1-17 through V2-T1-20 600 Vac Heavy-Duty, Fusible, Single-Throw ●30–1200A ●Horsepower rated ●Suitable for service entrance use, except 1200A on 480Y/277 or 600Y/347 grounded wye systems, per NEC 215.10 and 230.95, and four-pole switches ●For factory modifications, refer to Pages V2-T1-17 through V2-T1-20 600 Vac Heavy-Duty, Non- Fusible, Single-Throw ●30–1200A ●Horsepower rated ●Suitable for service entrance use, except 1200A on 480Y/277V or 600Y/347V grounded wye systems, per NEC 215.10 and 230.95, and four-pole switches ●For factory modifications, refer to Pages V2-T1-17 through V2-T1-20 Application Description For heavy commercial and industrial applications where reliable performance and service continuity are critical. For the toughest heavy commercial and industrial applications, refer to Page V2-T1-77 for catalog information on our mill-duty safety switch V2-T1-30 Volume 2—Commercial Distribution CA08100003E—May 2012 www.eaton.com 1 1.1 Switching Devices Safety Switches Features, Benefits and Functions ●Visible double-break quick- make, quick-break rotary blade mechanism. Two points of contact provide a positive open and close, easier operation, and also help prevent contact burning for longer contact life ●Triple padlocking capability. Personnel safety feature since the large hasp can accommodate up to three 3/8-inch (9.5 mm) shank locks. Cabinet door can be further padlocked at the top and bottom ●Interlocking mechanism. Door cannot be opened when the handle is in the ON position. Built-in defeater mechanism provides for user access when necessary ●Deionizing arc chutes; arc chutes confine and suppress the arcs produced by opening contacts under load ●Mechanically interlocked cover to prevent easy access when the switch is in the ON position ●Clear line shield with probe holes ●Clearly visible palm fitting red handle ●Tangential knockouts on NEMA 1 and NEMA 3R enclosures through 200A ●Built-in fuse pullers on NEMA 4X and NEMA 12 enclosures through 200A ●Additional door locking capability ●Complete accessory and renewal parts data shown on inner door label. ●30–800A NEMA 12 designs convertible to NEMA 3R by opening factory-installed drain hole ●30–1200A switches are seismic qualified and exceed the requirements of the Uniform Building Code® (UBC) and California Code Title 24 ●Tri-lingual nameplates All general-duty switches above 100A and all heavy- duty switches incorporate these K-Series switch design features. ●Two points of contact provide a positive open and close, easier operation, and also help prevent contact burning for longer contact life Visible Double-Break Rotary Blade Mechanism ●Protects against accidental contact with energized parts. Probe holes enable the user to test if the line side is energized without removing the shield. Not typically provided on general-duty switches, but available as a field kit or factory installed Clear Line Shield ●Provide easy removal of fuses Built-In Fuse Pullers (NEMA 12 and 4X 30–200A Only) ●The position (ON or OFF) can be clearly seen from a distance and the length provides for easy operation Clearly Visible Handle ●Personnel safety feature since the large hasp can accommodate up to three 3/8-inch (9.5 mm) shank locks Triple Padlocking Capability ●Cabinet door can be further padlocked at the top and bottom as applicable Additional Locking Capability ●Door cannot be opened when the handle is in the ON position. Front and side operable defeater mechanism provides for user access when necessary on single- throw switches Interlocking Mechanism ●An ample number are provided on the top, bottom and sides of both NEMA Types 1 and 3R enclosures through 200A Tangential Knockouts ●For switches in a NEMA Type 3R, 30–200A. Use a Myers type hub for all others Bolt-On Hub Kits Standards and Certifications ●UL listed File No. E5239 ●Meets UL 98 for enclosed switches and NEMA Std. KS-1 Volume 2—Commercial Distribution CA08100003E—May 2012 www.eaton.com V2-T1-21 1 1.1Switching Devices Safety Switches Technical Data and Specifications Standard Lug Capacities Dimensions Approximate Dimensions in Inches (mm) Plate Type Hubs For NEMA 3R enclosures (up to 200A) Catalog number DS900AP adapter kit permits Installation of Group 1 hubs on 200A type general-duty, heavy-duty and double-throw switches. Notes 1 The maximum size aluminum or copper-clad aluminum wire allowable for applications where the conductor enters or leaves the enclosure through the wall opposite its terminal is #1 gauge. Although certain lug capacities are larger than required, only minimum wire bending space is provided per the requirements noted in NEC® Tables 373-6 (a) and (b) for respective ampere ratings. Description Minimum Wire Size Maximum Wire Size Wire Type 30A DP #14 #12 #10 #10 Cu or Al 30A DG #14 #6 Cu/Al 30A DH, DT #14 #2 Cu/Al 60A DG #14 #1/0 Cu/Al 60A DH, DT #14 #2 Cu/Al 100A DG 1 #14 #1/0 Cu/Al 100A DH, DT #14 #1/0 Cu/Al 200A DG, DT #6 250 kcmil Cu/Al 200A DH Type 1 and 3R #6 250 kcmil Cu/Al 200A DH Type 4 and 12 #6 300 kcmil Cu/Al 400A DG, DH, DT (2) #1/0 (1) #1/0 (2) 300 kcmil (1) 750 kcmil Cu/Al or Cu/Al 600A DG, DH, fusible DT (1) #2 (1) #1/0 (1) 600 kcmil (1) 750 kcmil Cu/Al and Cu/Al 600A non-fusible DT (2) #250 (2) 500 kcmil Cu/Al 800A DH (4) #1/0 (4) 750 kcmil Cu/Al 800A DT (3) #250 (3) 500 kcmil Cu/Al 1200A DH, DT (4) #1/0 (4) 750 kcmil Cu/Al Copper-Bodied Lugs 30A Cu #14 #6 Cu 60A Cu #14 #4 Cu 100A Cu #6 #1/0 Cu 200A Cu #6 250 kcmil Cu 400A Cu #1/0 500 kcmil Cu 600A Cu (2) #1/0 (2) 500 kcmil Cu Group 1 General-Duty, Heavy-Duty, Double-Throw Through 100A Group 2 General-Duty, Heavy-Duty, Double-Throw—200A Catalog Number Conduit Size Catalog Number Conduit Size DS075H1 0.75 (19.1)DS200H2 2.00 (50.8) DS100H1 1.00 (25.4)DS250H2 2.50 (63.5) DS125H1 1.25 (31.8)DS300H2 3.00 (76.2) DS150H1 1.50 (38.1)—— DS200H1 2.00 (50.8)—— DS075H1 Detail Bill of Material Page 1 of 1 Project Name: STONE QUARRY Negotiation No: SY880507X4K1 General Order No: Alternate No: 0003 Item No. Qty Product Description 39 AC DISCONNECTS 60A/2P Air Conditioning Non-Fused Disconnect 240V Catalog No DPU222R Designation ACC'S, DSS'S Qty List of Materials 39 60A/2P Air Conditioning Non-Fused Disconnect 240V Eaton Selling Policy 25-000 applies. All orders must be released for manufacture within 90 days of date of order entry. If approval drawings are required, drawings must be returned approved for release within 60 days of mailing. If drawings are not returned accordingly, and/or if shipment is delayed for any reason, the price of the order will increase by 1.0% per month or fraction there of for the time the shipment is delayed. V1-T7-2 Volume 1—Residential and Light Commercial CA08100002E—August 2012 www.eaton.com 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7.1 Air Conditioning Disconnects Fused, Unfused and Molded Case Switch Complete Line of Fused, Unfused and Molded Case Switch Type Air Conditioning Disconnects Air Conditioning Disconnects Contents Description Page Features, Benefits and Functions. . . . . . . . . . . . . .V1-T7-3 Standards and Certifications . . . . . . . . . . . . . . . . .V1-T7-3 Product Selection. . . . . . . . . . . . . . . . . . . . . . . . . .V1-T7-4 Cross-Reference . . . . . . . . . . . . . . . . . . . . . . . . . .V1-T7-6 Technical Data and Specifications . . . . . . . . . . . . .V1-T7-7 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V1-T7-7 Product Description An air conditioning disconnect (ACD) is a disconnect located between a loadcenter (distribution panel) and air conditioner. Eaton’s ACD product line provides an installer or repair personnel with a visible disconnecting means when performing maintenance. ACDs are also known as disconnects, pullouts or air conditioning switches. Non-fused pullout and molded case switch devices provide personnel with a visible ON-OFF disconnecting means. While fused pullout units also perform this function, they also provide an additional level of protection for the air conditioner. Fused and non-fused devices are of a pullout design, where the user physically removes or “pulls out” a tab to break the electrical connection. A molded case switch is similar to a light switch where the user “switches” the unit to the indicated ON-OFF position. Fused and Non-Fused Pullouts ●ON/OFF control provided by a pullout handle ●Pullout handle can be conveniently stored in the compartment in the OFF position, helping to prevent the handle from being misplaced ●Protective shield cannot be removed until the pullout handle is removed, disconnecting the power Molded Case Switch ●Rugged molded case construction in a disconnect switch that looks like a circuit breaker but operates like an ordinary household light switch ●Plug-in molded case switch (included) eliminates the need for pullout handles ●No need for replacement pullout handles due to loss or theft Application Description The most widely used application for ACDs is for residential and light commercial air conditioning units. An ACD is installed outdoors, in visible proximity to the air conditioner condensing unit. ACDs are also found in use with heat pumps, swimming pools, spas, whirlpools and pump houses, and meet 2008 NEC Article 422.31 (B) requirements for servicing electric water heaters. Metallic enclosures are galvanized steel and are installed in various locations. Non-metallic enclosures are a plastic (polycarbonate) enclosure commonly used in coastal or salt-water areas. Volume 1—Residential and Light Commercial CA08100002E—August 2012 www.eaton.com V1-T7-3 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7.1Air Conditioning Disconnects Fused, Unfused and Molded Case Switch Features, Benefits and Functions ●Single-phase, two-wire, 240 Vac and three-phase, three-wire, 240 Vac ●NEMA 3R outdoor enclosures offered in metallic and non-metallic versions ●Easy-to-remove high- strength protective shield for easier wiring and mounting ●Easy-to-remove front cover (no screws or fasteners to remove) ●1-inch knockouts on the bottom, back and side of unit ●Copper-rated line and load lugs that are easily accessible ●Ample wiring space for mounting with a stud gun (single keyhole, two- or three-point mounting) ●Fused devices are service entrance rated Note: Fused non-metallic units require the addition of GB4NM ground bar to obtain a Service Entrance rating. ●Horsepower rated (10 hp maximum at 240 Vac) ●Padlockable door provision for safety and reduction of tampering ●Metallic enclosures are bottom entry and exit only ●Non-metallic enclosures have knockouts and a hub provision for top access ●Non-metallic enclosures have a single unit door and protective shield for installer convenience ●Non-metallic enclosures are durable and provide excellent resistance to climate changes ●Factory-installed tamper- resistant/weather-resistant receptacles are available as an option on some products Standards and Certifications ●UL listed File No. E132354, E143893, E196365 Contact Eaton for details and part numbers for CSA approved units. V1-T7-4 Volume 1—Residential and Light Commercial CA08100002E—August 2012 www.eaton.com 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7.1 Air Conditioning Disconnects Fused, Unfused and Molded Case Switch Product Selection Non-Fused Pullouts Fused Pullouts For Service Entrance applications, see footnotes below. Molded Case Switch Notes 1 For replacement pullout head, order part number 96-3258-4. 2 To obtain a Service Entrance Rating, the addition of a DPFG (ground bar kit) is required. 3 For replacement molded case switch, order part number BR260NA. Main Ampere Rating Maximum hp Rating Wire Size Range Cu/Al 60ºC or 75ºC Catalog Number120V 240V Galvanized Steel 60 — 10 #14–3 DPU222R 1 Non-Metallic/Polycarbonate Enclosure 60 — 10 #14–2 ACD222URNM-A2 1 Main Ampere Rating Maximum hp Rating Wire Size Range Cu/Al 60ºC or 75ºC Catalog Number120V 240V Galvanized Steel 30 2 2 3 #14–3 DPF221R 1 60 2 3 10 #14–3 DPF222R 1 Non-Metallic 30 2 3 #14–2 ACD221RNM-A2 1 60 3 10 #14–2 ACD222RNM-A2 1 Main Ampere Rating Maximum hp Rating Wire Size Range Cu/Al 60ºC or 75ºC Catalog Number120V 240V Galvanized Steel 60 — 10 #14–3 DPB222R 3 Non-Metallic/Polycarbonate Enclosure 60 — 10 #14–2 B60NARNM-A2 3 DPU222R DPF222R DPB222R Volume 1—Residential and Light Commercial CA08100002E—August 2012 www.eaton.com V1-T7-7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7.1Air Conditioning Disconnects Fused, Unfused and Molded Case Switch Technical Data and Specifications ●10,000 amperes rms symmetrical interrupting rating ●Horsepower rated ●Fusible and non-fusible pullout and molded case switch designs ●30 and 60 amperes available in fusible ●60 amperes available in non-fusible and molded case switch ●Class H fuse clips provided on fusible pullout design ●WRTR (weather-resistant/ tamper-resistant) receptacle options available Dimensions Approximate Dimensions in Inches (mm) Dimensions and Shipping Carton Information Note 1 Eaton Quick Pro designated item. Catalog Number Carton Quantity Dimensions in Inches (mm) Weight Lbs (kg)Height Width Depth Metallic/Galvanized Steel Enclosure DPF221R 10 8.70 (220.9) 5.40 (137.2) 3.15 (80.0) 27 (12) DPF222R 10 8.70 (220.9) 5.40 (137.2) 3.15 (80.0) 27 (12) DPU222R 10 8.70 (220.9) 5.40 (137.2) 3.15 (80.0) 27 (12) DPB222R 10 8.60 (218.4) 5.30 (134.6) 3.74 (95.0) 34 (15) DPU222R12W 1 1 14.75 (374.6) 12.50 (317.5) 4.00 (101.6) 6 (3) DPU222R34W 1 1 14.75 (374.6) 12.50 (317.5) 4.00 (101.7) 6 (3) DPU222RGF20 1 13.00 (330.2) 7.50 (190.5) 4.75 (120.7) 8 (4) DPF221RGF20 1 13.00 (330.2) 7.50 (190.5) 4.75 (120.7) 8 (4) DPF222RGF20 1 13.00 (330.2) 7.50 (190.5) 4.75 (120.7) 8 (4) DPU222RGF15 1 13.00 (330.2) 7.50 (190.5) 4.75 (120.7) 8 (4) DPF221RGF15 1 13.00 (330.2) 7.50 (190.5) 4.75 (120.7) 8 (4) DPF222RGF15 1 13.00 (330.2) 7.50 (190.5) 4.75 (120.7) 8 (4) DPF221RGF15WRTR 1 13.00 (330.2) 7.50 (190.5) 4.75 (120.7) 8 (4) DPF221RGF20WRTR 1 13.00 (330.2) 7.50 (190.5) 4.75 (120.7) 8 (4) DPF222RGF15WRTR 1 13.00 (330.2) 7.50 (190.5) 4.75 (120.7) 8 (4) DPF222RGF20WRTR 1 13.00 (330.2) 7.50 (190.5) 4.75 (120.7) 8 (4) DPU222RGF15WRTR 1 13.00 (330.2) 7.50 (190.5) 4.75 (120.7) 8 (4) DPU222RGF20WRTR 1 13.00 (330.2) 7.50 (190.5) 4.75 (120.7) 8 (4) DPU362R 1 8.60 (218.4) 5.30 (134.6) 3.74 (94.9) 4 (2) Non-Metallic/Polycarbonate Enclosure ACD221RNM-A2 10 8.63 (219.0) 6.26 (159.0) 4.33 (109.9) 15 (7) ACD222RNM-A2 10 8.63 (219.0) 6.26 (159.0) 4.33 (109.9) 15 (7) ACD222URNM-A2 10 8.63 (219.0) 6.26 (159.0) 4.33 (109.9) 15 (7) B60NARNM-A2 10 8.63 (219.0) 6.26 (159.0) 4.33 (109.9) 18 (8) V1-T7-8 Volume 1—Residential and Light Commercial CA08100002E—August 2012 www.eaton.com 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7.1 Air Conditioning Disconnects Fused, Unfused and Molded Case Switch Approximate Dimensions in Inches (mm) DPF221R, DPF222R, DPU222R, DPU222R12W and DPU222R34W 5.40 (137.2) 8.79 (223.4) 2.54 (64.4) 3.15 (80.1) 7 Knockouts for 1/2 (12.7), 3/4 (19.1) or 1 (25.4) Conduit 0.28 (7.1) Diameter Knockout—1 Req‘d. 0.26 (6.5) Dia. 3 Holes Req’d. 0.25 (6.4) 2.00 (50.8) 4.00 (101.6) 1.47 (37.2) 8.70 (221.0) 5.26 (133.6) 5.14 (130.6) 1.11 (28.2) 5.25 (133.5) 1.05 (26.7) 1.50 (38.1) 3.00 (76.2) 0.55 (14.0) 1.13 (28.7) 2.97 (75.3) 2.39 (60.8) 1.13 (28.7) 1.65 (41.9)1.09 (27.7) 1.00 (25.4) 1.55 (39.4) 5.10 (129.5) 1.55 (39.4) Detail Bill of Material Page 1 of 2 Project Name: STONE QUARRY Negotiation No: SY880507X4K1 General Order No: Alternate No: 0003 Item No. Qty Product Description 16 BR LOAD CENTERS 1Ph/BR Loadcenter 125A MLO 16/16Cir. Al Bus Nema 1 Catalog No BR1616L125 Designation THP Qty List of Materials 16 1Ph/BR Loadcenter 125A MLO 16/16Cir. Al Bus Nema 1 Item No. Qty Product Description 16 CH LOAD CENTERS Ground Bar Kit - 21 Terminal Catalog No GBK21 Designation THP Qty List of Materials 16 Ground Bar Kit - 21 Terminal Item No. Qty Product Description 16 BR RESIDENTIAL BREAKERS Type BR Breaker 20A/2 Pole 120/240V 10K Catalog No BR220 Designation THP Qty List of Materials 16 Type BR Breaker 20A/2 Pole 120/240V 10K Item No. Qty Product Description 16 BR RESIDENTIAL BREAKERS Type BR Breaker 15A/1 Pole 120/240V 10K Catalog No BR115 Designation THP Qty List of Materials 16 Type BR Breaker 15A/1 Pole 120/240V 10K Item No. Qty Product Description 80 BR RESIDENTIAL BREAKERS Type BR Breaker 20A/1 Pole 120/240V 10k Catalog No BR120 Designation THP Qty List of Materials 80 Type BR Breaker 20A/1 Pole 120/240V 10k Detail Bill of Material Page 2 of 2 Project Name: STONE QUARRY Negotiation No: SY880507X4K1 General Order No: Alternate No: 0003 Item No. Qty Product Description 16 BR AFCI BREAKERS TYPE BR COMBINATION AFCI, 1P, 15A, 10KAIC Catalog No BRCAF115 Designation THP Qty List of Materials 16 TYPE BR COMBINATION AFCI, 1P, 15A, 10KAIC Item No. Qty Product Description 48 BR AFCI BREAKERS TYPE BR COMBINATION AFCI, 1P, 20A, 10KAIC Catalog No BRCAF120 Designation THP Qty List of Materials 48 TYPE BR COMBINATION AFCI, 1P, 20A, 10KAIC Detail Bill of Material Page 1 of 2 Project Name: STONE QUARRY Negotiation No: SY880507X4K1 General Order No: Alternate No: 0003 Item No. Qty Product Description 17 BR LOAD CENTERS 1Ph/BR Loadcenter 125A MLO 16/16Cir. Al Bus Nema 1 Catalog No BR1616L125 Designation AP1 Qty List of Materials 17 1Ph/BR Loadcenter 125A MLO 16/16Cir. Al Bus Nema 1 Item No. Qty Product Description 17 CH LOAD CENTERS Ground Bar Kit - 21 Terminal Catalog No GBK21 Designation AP1 Qty List of Materials 17 Ground Bar Kit - 21 Terminal Item No. Qty Product Description 17 BR RESIDENTIAL BREAKERS Type BR Breaker 20A/2 Pole 120/240V 10K Catalog No BR220 Designation AP1 Qty List of Materials 17 Type BR Breaker 20A/2 Pole 120/240V 10K Item No. Qty Product Description 17 BR RESIDENTIAL BREAKERS Type BR Breaker 15A/1 Pole 120/240V 10K Catalog No BR115 Designation AP1 Qty List of Materials 17 Type BR Breaker 15A/1 Pole 120/240V 10K Item No. Qty Product Description 85 BR RESIDENTIAL BREAKERS Type BR Breaker 20A/1 Pole 120/240V 10k Catalog No BR120 Designation AP1 Qty List of Materials 85 Type BR Breaker 20A/1 Pole 120/240V 10k Detail Bill of Material Page 2 of 2 Project Name: STONE QUARRY Negotiation No: SY880507X4K1 General Order No: Alternate No: 0003 Item No. Qty Product Description 34 BR AFCI BREAKERS TYPE BR COMBINATION AFCI, 1P, 15A, 10KAIC Catalog No BRCAF115 Designation AP1 Qty List of Materials 34 TYPE BR COMBINATION AFCI, 1P, 15A, 10KAIC Item No. Qty Product Description 17 BR AFCI BREAKERS TYPE BR COMBINATION AFCI, 1P, 20A, 10KAIC Catalog No BRCAF120 Designation AP1 Qty List of Materials 17 TYPE BR COMBINATION AFCI, 1P, 20A, 10KAIC Detail Bill of Material Page 1 of 2 Project Name: STONE QUARRY Negotiation No: SY880507X4K1 General Order No: Alternate No: 0003 Item No. Qty Product Description 2 BR LOAD CENTERS 1Ph/BR Loadcenter 125A MLO 16/16Cir. Al Bus Nema 1 Catalog No BR1616L125 Designation AP2 Qty List of Materials 2 1Ph/BR Loadcenter 125A MLO 16/16Cir. Al Bus Nema 1 Item No. Qty Product Description 2 CH LOAD CENTERS Ground Bar Kit - 21 Terminal Catalog No GBK21 Designation AP2 Qty List of Materials 2 Ground Bar Kit - 21 Terminal Item No. Qty Product Description 2 BR RESIDENTIAL BREAKERS Type BR Breaker 20A/2 Pole 120/240V 10K Catalog No BR220 Designation AP2 Qty List of Materials 2 Type BR Breaker 20A/2 Pole 120/240V 10K Item No. Qty Product Description 2 BR RESIDENTIAL BREAKERS Type BR Breaker 15A/1 Pole 120/240V 10K Catalog No BR115 Designation AP2 Qty List of Materials 2 Type BR Breaker 15A/1 Pole 120/240V 10K Item No. Qty Product Description 12 BR RESIDENTIAL BREAKERS Type BR Breaker 20A/1 Pole 120/240V 10k Catalog No BR120 Designation AP2 Qty List of Materials 12 Type BR Breaker 20A/1 Pole 120/240V 10k Detail Bill of Material Page 2 of 2 Project Name: STONE QUARRY Negotiation No: SY880507X4K1 General Order No: Alternate No: 0003 Item No. Qty Product Description 4 BR AFCI BREAKERS TYPE BR COMBINATION AFCI, 1P, 15A, 10KAIC Catalog No BRCAF115 Designation AP2 Qty List of Materials 4 TYPE BR COMBINATION AFCI, 1P, 15A, 10KAIC Item No. Qty Product Description 2 BR AFCI BREAKERS TYPE BR COMBINATION AFCI, 1P, 20A, 10KAIC Catalog No BRCAF120 Designation AP2 Qty List of Materials 2 TYPE BR COMBINATION AFCI, 1P, 20A, 10KAIC 4 123 B C D A B C D 3 2 TITLE SHEET DRAFTER/DESIGNER DATE (YYYY/MM/DD) DRAWING NUMBER REVISIONSIZEEATON CORPORATION - CONFIDENTIAL AND PROPRIETARY UNLESS OTHERWISE SPECIFIED DIMENSIONS IN SCALE OF THIS DOCUMENT, INCLUDING THE DRAWING AND INFORMATION CONTAINED THEREON, IS CONFIDENTIAL AND IS THE EXCLUSIVE PROPERTY OF EATON CORPORATION, AND IS MERELY ON LOAN AND SUBJECT TO RECALL BY EATON AT ANY TIME. BY TAKING POSSESSION OF THIS DOCUMENT, THE RECIPIENT ACKNOWLEDGES AND AGREES THAT THIS DOCUMENT CANNOT BE USED IN ANY MANNER ADVERSE TO THE INTERESTS OF EATON AND THAT NO PORTION OF THIS DOCUMENT MAY BE COPIED OR OTHERWISE REPRODUCED WITHOUT THE PRIOR WRITTEN CONSENT OF EATON. IN THE CASE OF CONFLICTING CONTRACTUAL PROVISIONS, THIS NOTICE SHALL GOVERN THE STATUS OF THIS DOCUMENT. NOTICE TO PERSONS RECEIVING THIS DOCUMENT AND/OR TECHNICAL INFORMATION C Eaton Corporation, All Rights Reserved A DSD_AFM_PORT_ACAD_CUSTOMER.DWG A 2014 211=6 INCHES 00198-1083 2014/06/27M. EganBR 1" LOADCENTER, MAIN LUG ONLY, INDOOR NEMA 1, 120/240 VAC, 1 PHASE TYPE BR LOADCENTER RATINGS: Enclosure: Indoor NEMA 1 Incoming Main: Main Lug Only Loadcenter Electrical Rating: 120/240 VAC, Single Phase Bus Bar Ampere: 125 Amps Max Number of Spaces & Circuits: See Table on Page 2 Incoming Wire Range: #6-2/0 Bus Bar Material: Tin Plated Aluminum (Standard) Trim Type: Combination (Standard) Trim Paint: ANSI 61 Light Gray Short Circuit Rating: See Branch Breaker Ratings Box Dimensions: 14.3"W x 3.9"D x "A" (See Table on page 2) FEATURES: Steel Backpan - For reliable breaker mounting. Single keyhole mounting - One keyhole at top and bottom for mounting and leveling. Split Neutral Bar Assembly - For better management of load wires. Drywall marking on Enclosure - Indicates mounting depth for flush applications Top or bottom feed - Acceptable for either top or or bottom applications. Warranty - 10 year limited warranty on all BR Loadcenters and Breakers. OPTIONAL ACCESSORIES: Catalog Number Description GBK5 5 POS #14-4 Ground Bar GBK10 10 POS #14-4 Ground Bar GBK14 14 POS #14-4 Ground Bar GBK21 21 POS #14-4 Ground Bar NL20 Neutral/Ground Lug #2/0 max BRFP 1" Filler Plate BREQS125 Hold-down kit for Type BR breaker BR230SUR BR 2P 30A Circuit Breaker w/ Surge Protection Ref: 96-3549 14.3 3.9 "A" Page: 1 of 2 GO/NEG-Alt-Date: Job Name: Item Number: Catalog Number: Designation: SY880507X4K1-0003-12/17/2014 STONE QUARRY BR1616L125 THP 4 123 B C D A B C D 3 2 TITLE SHEET DRAFTER/DESIGNER DATE (YYYY/MM/DD) DRAWING NUMBER REVISIONSIZEEATON CORPORATION - CONFIDENTIAL AND PROPRIETARY UNLESS OTHERWISE SPECIFIED DIMENSIONS IN SCALE OF THIS DOCUMENT, INCLUDING THE DRAWING AND INFORMATION CONTAINED THEREON, IS CONFIDENTIAL AND IS THE EXCLUSIVE PROPERTY OF EATON CORPORATION, AND IS MERELY ON LOAN AND SUBJECT TO RECALL BY EATON AT ANY TIME. BY TAKING POSSESSION OF THIS DOCUMENT, THE RECIPIENT ACKNOWLEDGES AND AGREES THAT THIS DOCUMENT CANNOT BE USED IN ANY MANNER ADVERSE TO THE INTERESTS OF EATON AND THAT NO PORTION OF THIS DOCUMENT MAY BE COPIED OR OTHERWISE REPRODUCED WITHOUT THE PRIOR WRITTEN CONSENT OF EATON. IN THE CASE OF CONFLICTING CONTRACTUAL PROVISIONS, THIS NOTICE SHALL GOVERN THE STATUS OF THIS DOCUMENT. NOTICE TO PERSONS RECEIVING THIS DOCUMENT AND/OR TECHNICAL INFORMATION C Eaton Corporation, All Rights Reserved A DSD_AFM_PORT_ACAD_CUSTOMER.DWG A 2014 221=1 INCHES 00198-1083 2014/06/27M. EganBR 1" LOADCENTER, MAIN LUG ONLY, INDOOR NEMA 1, 120/240 VAC, 1 PHASE LOADCENTER DETAILS Catalog #Dim "A"Main Lug Amps Spaces / Circuits Bus Material Wire Size Range Cu/Al 60°C or 75°C Notes BR1212L125 16.75 125 12/12 Alum.#6-2/0 BR1224L125 16.75 125 12/24 Alum.#6-2/0 BR1224L125DG 16.75 125 12/24 Alum.#6-2/0 5 ground terminals included plus 2/0 lug BR1224L125G 16.75 125 12/24 Alum.#6-2/0 8 ground terminals included BR1224L125P 16.75 125 12/24 Alum.#6-2/0 BR1616L125 18.75 125 16/16 Alum.#6-2/0 BR1624L125 18.75 125 16/24 Alum.#6-2/0 BR1624L125G 18.75 125 16/24 Alum.#6-2/0 10 ground terminals included plus 2/0 lug BR1624L125GBP 18.75 125 16/24 Alum.#6-2/0 10 ground terminals included plus 2/0 lug BR2020L125 21 125 20/20 Alum.#6-2/0 BR2024L125 21 125 20/24 Alum.#6-2/0 BR2024L125G 21 125 20/24 Alum.#6-2/0 12 ground terminals included plus 2/0 lug BR2024L125P 21 125 20/24 Alum.#6-2/0 BR2424L125 23 125 24/24 Alum.#6-2/0 BR2424L125B 23 125 24/24 Alum.#6-2/0 BR2424L125G 23 125 24/24 Alum.#6-2/0 12 ground terminals included plus 2/0 lug BR2424L125GBP 23 125 24/24 Alum.#6-2/0 12 ground terminals included plus 2/0 lug BR2430L125G 23 125 24/30 Alum.#6-2/0 14 ground terminals included plus 2/0 lug BR3042L125 29 125 30/42 Alum.#6-2/0 Note: Catalog Numbers may have addtional characters at the end which describe alternate details, including but not limited to the following: S, F, W, G, GK, PK, PB, SF, RN, MI, V and #s. Contact sales for those specific details when necessary. Page: 2 of 2 GO/NEG-Alt-Date: Job Name: Item Number: Catalog Number: Designation: SY880507X4K1-0003-12/17/2014 STONE QUARRY BR1616L125 THP 4 123 B C D A B C D 3 2 TITLE SHEET DRAFTER/DESIGNER DATE (YYYY/MM/DD) DRAWING NUMBER REVISIONSIZEEATON CORPORATION - CONFIDENTIAL AND PROPRIETARY UNLESS OTHERWISE SPECIFIED DIMENSIONS IN SCALE OF THIS DOCUMENT, INCLUDING THE DRAWING AND INFORMATION CONTAINED THEREON, IS CONFIDENTIAL AND IS THE EXCLUSIVE PROPERTY OF EATON CORPORATION, AND IS MERELY ON LOAN AND SUBJECT TO RECALL BY EATON AT ANY TIME. BY TAKING POSSESSION OF THIS DOCUMENT, THE RECIPIENT ACKNOWLEDGES AND AGREES THAT THIS DOCUMENT CANNOT BE USED IN ANY MANNER ADVERSE TO THE INTERESTS OF EATON AND THAT NO PORTION OF THIS DOCUMENT MAY BE COPIED OR OTHERWISE REPRODUCED WITHOUT THE PRIOR WRITTEN CONSENT OF EATON. IN THE CASE OF CONFLICTING CONTRACTUAL PROVISIONS, THIS NOTICE SHALL GOVERN THE STATUS OF THIS DOCUMENT. NOTICE TO PERSONS RECEIVING THIS DOCUMENT AND/OR TECHNICAL INFORMATION C Eaton Corporation, All Rights Reserved A DSD_AFM_PORT_ACAD_CUSTOMER.DWG A 2014 211=6 INCHES 00198-1083 2014/06/27M. EganBR 1" LOADCENTER, MAIN LUG ONLY, INDOOR NEMA 1, 120/240 VAC, 1 PHASE TYPE BR LOADCENTER RATINGS: Enclosure: Indoor NEMA 1 Incoming Main: Main Lug Only Loadcenter Electrical Rating: 120/240 VAC, Single Phase Bus Bar Ampere: 125 Amps Max Number of Spaces & Circuits: See Table on Page 2 Incoming Wire Range: #6-2/0 Bus Bar Material: Tin Plated Aluminum (Standard) Trim Type: Combination (Standard) Trim Paint: ANSI 61 Light Gray Short Circuit Rating: See Branch Breaker Ratings Box Dimensions: 14.3"W x 3.9"D x "A" (See Table on page 2) FEATURES: Steel Backpan - For reliable breaker mounting. Single keyhole mounting - One keyhole at top and bottom for mounting and leveling. Split Neutral Bar Assembly - For better management of load wires. Drywall marking on Enclosure - Indicates mounting depth for flush applications Top or bottom feed - Acceptable for either top or or bottom applications. Warranty - 10 year limited warranty on all BR Loadcenters and Breakers. OPTIONAL ACCESSORIES: Catalog Number Description GBK5 5 POS #14-4 Ground Bar GBK10 10 POS #14-4 Ground Bar GBK14 14 POS #14-4 Ground Bar GBK21 21 POS #14-4 Ground Bar NL20 Neutral/Ground Lug #2/0 max BRFP 1" Filler Plate BREQS125 Hold-down kit for Type BR breaker BR230SUR BR 2P 30A Circuit Breaker w/ Surge Protection Ref: 96-3549 14.3 3.9 "A" Page: 1 of 2 GO/NEG-Alt-Date: Job Name: Item Number: Catalog Number: Designation: SY880507X4K1-0003-12/17/2014 STONE QUARRY BR1616L125 AP1 4 123 B C D A B C D 3 2 TITLE SHEET DRAFTER/DESIGNER DATE (YYYY/MM/DD) DRAWING NUMBER REVISIONSIZEEATON CORPORATION - CONFIDENTIAL AND PROPRIETARY UNLESS OTHERWISE SPECIFIED DIMENSIONS IN SCALE OF THIS DOCUMENT, INCLUDING THE DRAWING AND INFORMATION CONTAINED THEREON, IS CONFIDENTIAL AND IS THE EXCLUSIVE PROPERTY OF EATON CORPORATION, AND IS MERELY ON LOAN AND SUBJECT TO RECALL BY EATON AT ANY TIME. BY TAKING POSSESSION OF THIS DOCUMENT, THE RECIPIENT ACKNOWLEDGES AND AGREES THAT THIS DOCUMENT CANNOT BE USED IN ANY MANNER ADVERSE TO THE INTERESTS OF EATON AND THAT NO PORTION OF THIS DOCUMENT MAY BE COPIED OR OTHERWISE REPRODUCED WITHOUT THE PRIOR WRITTEN CONSENT OF EATON. IN THE CASE OF CONFLICTING CONTRACTUAL PROVISIONS, THIS NOTICE SHALL GOVERN THE STATUS OF THIS DOCUMENT. NOTICE TO PERSONS RECEIVING THIS DOCUMENT AND/OR TECHNICAL INFORMATION C Eaton Corporation, All Rights Reserved A DSD_AFM_PORT_ACAD_CUSTOMER.DWG A 2014 221=1 INCHES 00198-1083 2014/06/27M. EganBR 1" LOADCENTER, MAIN LUG ONLY, INDOOR NEMA 1, 120/240 VAC, 1 PHASE LOADCENTER DETAILS Catalog #Dim "A"Main Lug Amps Spaces / Circuits Bus Material Wire Size Range Cu/Al 60°C or 75°C Notes BR1212L125 16.75 125 12/12 Alum.#6-2/0 BR1224L125 16.75 125 12/24 Alum.#6-2/0 BR1224L125DG 16.75 125 12/24 Alum.#6-2/0 5 ground terminals included plus 2/0 lug BR1224L125G 16.75 125 12/24 Alum.#6-2/0 8 ground terminals included BR1224L125P 16.75 125 12/24 Alum.#6-2/0 BR1616L125 18.75 125 16/16 Alum.#6-2/0 BR1624L125 18.75 125 16/24 Alum.#6-2/0 BR1624L125G 18.75 125 16/24 Alum.#6-2/0 10 ground terminals included plus 2/0 lug BR1624L125GBP 18.75 125 16/24 Alum.#6-2/0 10 ground terminals included plus 2/0 lug BR2020L125 21 125 20/20 Alum.#6-2/0 BR2024L125 21 125 20/24 Alum.#6-2/0 BR2024L125G 21 125 20/24 Alum.#6-2/0 12 ground terminals included plus 2/0 lug BR2024L125P 21 125 20/24 Alum.#6-2/0 BR2424L125 23 125 24/24 Alum.#6-2/0 BR2424L125B 23 125 24/24 Alum.#6-2/0 BR2424L125G 23 125 24/24 Alum.#6-2/0 12 ground terminals included plus 2/0 lug BR2424L125GBP 23 125 24/24 Alum.#6-2/0 12 ground terminals included plus 2/0 lug BR2430L125G 23 125 24/30 Alum.#6-2/0 14 ground terminals included plus 2/0 lug BR3042L125 29 125 30/42 Alum.#6-2/0 Note: Catalog Numbers may have addtional characters at the end which describe alternate details, including but not limited to the following: S, F, W, G, GK, PK, PB, SF, RN, MI, V and #s. Contact sales for those specific details when necessary. Page: 2 of 2 GO/NEG-Alt-Date: Job Name: Item Number: Catalog Number: Designation: SY880507X4K1-0003-12/17/2014 STONE QUARRY BR1616L125 AP1 4 123 B C D A B C D 3 2 TITLE SHEET DRAFTER/DESIGNER DATE (YYYY/MM/DD) DRAWING NUMBER REVISIONSIZEEATON CORPORATION - CONFIDENTIAL AND PROPRIETARY UNLESS OTHERWISE SPECIFIED DIMENSIONS IN SCALE OF THIS DOCUMENT, INCLUDING THE DRAWING AND INFORMATION CONTAINED THEREON, IS CONFIDENTIAL AND IS THE EXCLUSIVE PROPERTY OF EATON CORPORATION, AND IS MERELY ON LOAN AND SUBJECT TO RECALL BY EATON AT ANY TIME. BY TAKING POSSESSION OF THIS DOCUMENT, THE RECIPIENT ACKNOWLEDGES AND AGREES THAT THIS DOCUMENT CANNOT BE USED IN ANY MANNER ADVERSE TO THE INTERESTS OF EATON AND THAT NO PORTION OF THIS DOCUMENT MAY BE COPIED OR OTHERWISE REPRODUCED WITHOUT THE PRIOR WRITTEN CONSENT OF EATON. IN THE CASE OF CONFLICTING CONTRACTUAL PROVISIONS, THIS NOTICE SHALL GOVERN THE STATUS OF THIS DOCUMENT. NOTICE TO PERSONS RECEIVING THIS DOCUMENT AND/OR TECHNICAL INFORMATION C Eaton Corporation, All Rights Reserved A DSD_AFM_PORT_ACAD_CUSTOMER.DWG A 2014 211=6 INCHES 00198-1083 2014/06/27M. EganBR 1" LOADCENTER, MAIN LUG ONLY, INDOOR NEMA 1, 120/240 VAC, 1 PHASE TYPE BR LOADCENTER RATINGS: Enclosure: Indoor NEMA 1 Incoming Main: Main Lug Only Loadcenter Electrical Rating: 120/240 VAC, Single Phase Bus Bar Ampere: 125 Amps Max Number of Spaces & Circuits: See Table on Page 2 Incoming Wire Range: #6-2/0 Bus Bar Material: Tin Plated Aluminum (Standard) Trim Type: Combination (Standard) Trim Paint: ANSI 61 Light Gray Short Circuit Rating: See Branch Breaker Ratings Box Dimensions: 14.3"W x 3.9"D x "A" (See Table on page 2) FEATURES: Steel Backpan - For reliable breaker mounting. Single keyhole mounting - One keyhole at top and bottom for mounting and leveling. Split Neutral Bar Assembly - For better management of load wires. Drywall marking on Enclosure - Indicates mounting depth for flush applications Top or bottom feed - Acceptable for either top or or bottom applications. Warranty - 10 year limited warranty on all BR Loadcenters and Breakers. OPTIONAL ACCESSORIES: Catalog Number Description GBK5 5 POS #14-4 Ground Bar GBK10 10 POS #14-4 Ground Bar GBK14 14 POS #14-4 Ground Bar GBK21 21 POS #14-4 Ground Bar NL20 Neutral/Ground Lug #2/0 max BRFP 1" Filler Plate BREQS125 Hold-down kit for Type BR breaker BR230SUR BR 2P 30A Circuit Breaker w/ Surge Protection Ref: 96-3549 14.3 3.9 "A" Page: 1 of 2 GO/NEG-Alt-Date: Job Name: Item Number: Catalog Number: Designation: SY880507X4K1-0003-12/17/2014 STONE QUARRY BR1616L125 AP2 4 123 B C D A B C D 3 2 TITLE SHEET DRAFTER/DESIGNER DATE (YYYY/MM/DD) DRAWING NUMBER REVISIONSIZEEATON CORPORATION - CONFIDENTIAL AND PROPRIETARY UNLESS OTHERWISE SPECIFIED DIMENSIONS IN SCALE OF THIS DOCUMENT, INCLUDING THE DRAWING AND INFORMATION CONTAINED THEREON, IS CONFIDENTIAL AND IS THE EXCLUSIVE PROPERTY OF EATON CORPORATION, AND IS MERELY ON LOAN AND SUBJECT TO RECALL BY EATON AT ANY TIME. BY TAKING POSSESSION OF THIS DOCUMENT, THE RECIPIENT ACKNOWLEDGES AND AGREES THAT THIS DOCUMENT CANNOT BE USED IN ANY MANNER ADVERSE TO THE INTERESTS OF EATON AND THAT NO PORTION OF THIS DOCUMENT MAY BE COPIED OR OTHERWISE REPRODUCED WITHOUT THE PRIOR WRITTEN CONSENT OF EATON. IN THE CASE OF CONFLICTING CONTRACTUAL PROVISIONS, THIS NOTICE SHALL GOVERN THE STATUS OF THIS DOCUMENT. NOTICE TO PERSONS RECEIVING THIS DOCUMENT AND/OR TECHNICAL INFORMATION C Eaton Corporation, All Rights Reserved A DSD_AFM_PORT_ACAD_CUSTOMER.DWG A 2014 221=1 INCHES 00198-1083 2014/06/27M. EganBR 1" LOADCENTER, MAIN LUG ONLY, INDOOR NEMA 1, 120/240 VAC, 1 PHASE LOADCENTER DETAILS Catalog #Dim "A"Main Lug Amps Spaces / Circuits Bus Material Wire Size Range Cu/Al 60°C or 75°C Notes BR1212L125 16.75 125 12/12 Alum.#6-2/0 BR1224L125 16.75 125 12/24 Alum.#6-2/0 BR1224L125DG 16.75 125 12/24 Alum.#6-2/0 5 ground terminals included plus 2/0 lug BR1224L125G 16.75 125 12/24 Alum.#6-2/0 8 ground terminals included BR1224L125P 16.75 125 12/24 Alum.#6-2/0 BR1616L125 18.75 125 16/16 Alum.#6-2/0 BR1624L125 18.75 125 16/24 Alum.#6-2/0 BR1624L125G 18.75 125 16/24 Alum.#6-2/0 10 ground terminals included plus 2/0 lug BR1624L125GBP 18.75 125 16/24 Alum.#6-2/0 10 ground terminals included plus 2/0 lug BR2020L125 21 125 20/20 Alum.#6-2/0 BR2024L125 21 125 20/24 Alum.#6-2/0 BR2024L125G 21 125 20/24 Alum.#6-2/0 12 ground terminals included plus 2/0 lug BR2024L125P 21 125 20/24 Alum.#6-2/0 BR2424L125 23 125 24/24 Alum.#6-2/0 BR2424L125B 23 125 24/24 Alum.#6-2/0 BR2424L125G 23 125 24/24 Alum.#6-2/0 12 ground terminals included plus 2/0 lug BR2424L125GBP 23 125 24/24 Alum.#6-2/0 12 ground terminals included plus 2/0 lug BR2430L125G 23 125 24/30 Alum.#6-2/0 14 ground terminals included plus 2/0 lug BR3042L125 29 125 30/42 Alum.#6-2/0 Note: Catalog Numbers may have addtional characters at the end which describe alternate details, including but not limited to the following: S, F, W, G, GK, PK, PB, SF, RN, MI, V and #s. Contact sales for those specific details when necessary. Page: 2 of 2 GO/NEG-Alt-Date: Job Name: Item Number: Catalog Number: Designation: SY880507X4K1-0003-12/17/2014 STONE QUARRY BR1616L125 AP2 V1-T1-42 Volume 1—Residential and Light Commercial CA08100002E—September 2014 www.eaton.com 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1.2 Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers Overview Product Selection Guide BR Loadcenters Description Service Single-phase, three-wire, 120/240 Vac Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta Short-Circuit Current Rating 10 kAIC: All single- and three-phase loadcenters 70–225 A, 8 to 42 circuits 22 kAIC: All convertible loadcenters using 125 A rated Type BRH main breakers or selected factory installed 125 A rated Type BRH main breaker 25 kAIC: All convertible and factory-installed single-phase loadcenters rated 150 and 200 A using Type CSR main breakers Main Breaker/Main Lug Loadcenters Single-phase Main breaker: 100, 125, 150, 200, 225, 400, 600 A Main lugs: 70, 125, 150, 200, 225, 400, 600 A Three-phase Main breaker: 100, 125, 150, 200, 225, 400, 600 A Main lugs: 100, 125, 150, 200, 225, 400, 600 A Convertible Loadcenters Main breaker: single-phase up to 200 A and three-phase up to 225 A Main lugs: single-phase up to 200 A and three-phase up to 150 A Branch Breakers Types BR, BRH and BRHH: 10–150 A. single-, two- and three-pole; selected amperage available in switching duty, HACR, shunt trip and high magnetic setting Type GFCB: 15–60 A Types BJ and BJH: 125–225 A; two- and three-pole Type BD Twin: 10–50 A; two of one-pole; take one 1-inch (25.4 mm) space Type BQ and BQC Multibreaker: 15–30 A. Two of two-pole or one two-pole and two one-pole; takes two 1-inch (25.4 mm) spaces Type BRW: 15–30 A; two-pole water heater breakers Type BRSN: 15–30 A; two-pole switching neutral breakers Type BR 15–100 A; two-pole, 240 Vac delta breakers BR-AFCI arc fault circuit interrupter Enclosures NEMA Type 1 indoor NEMA Type 3R outdoor NEMA 4X Meets or exceeds UL requirements for indoor or outdoor applications Loadcenter and Breaker Accessories Branch circuit breaker: Auxiliary components Hold-down kits Handle ties Lockoffs Lockdogs Complete line of ground bar kits 5, 10, 14 and 21 circuit, some with additional #2/0 lugs; each terminal will accommodate: (3) #14–#10 Cu/Al or (1) #14–#4 Cu/Al Main and sub-feed lugs 125, 150, 225 A—two- and three-pole Shunt trips Surge protection: Single-phase plug-on surge protector Single-phase bottle type surge protector Three-phase bottle type surge protector Single-phase whole home surge protector Universal rainproof conduit hubs Group One: 3/4, 1, 1-1/4, 1-1/2, 2 inches (19.1, 25.4, 31.8, 38.1, 50.8 mm) Group Two: 2, 2-1/2, 3 inches (50.8, 63.5, 76.2 mm) Adapter plate Bussing Tin-plated aluminum as standard Limited copper bus panels available Volume 1—Residential and Light Commercial CA08100002E—September 2014 www.eaton.com V1-T1-43 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1.2Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers Product Description Loadcenters are enclosures specifically designed to house the branch circuit breakers and wiring required to distribute power to individual circuits. They contain either a main breaker when used at the service entrance point or a main lug when used as a sub-panel to add circuits to existing service. The main breaker protects the main entire panel and can be used as a service disconnect. The branch breakers protect the wires leading to individual electrical loads such as fixtures and outlets. Features, Benefits and Functions Loadcenter Construction Eaton’s Type BR loadcenters have standard tin-plated aluminum bus with a limited availability of copper bus. The sum of the handle ratings connected to any stab is limited to 150 A maximum on the 100 and 125 A loadcenters, and 200 A on loadcenters with 150 A or higher main bus. NEMA Type 1 boxes or enclosures are manufactured from galvanized steel. Raintight boxes are manufactured from galvanized steel, then finished using an electrostatic powder coat, baked urethane paint process. Neutrals Eaton Type CH loadcenters feature two types of neutrals: Insulated/Bondable Split Neutral Panels are supplied with split insulated neutrals with an insulated cross strap. For service entrance applications, the neutral must be bonded by using the bonding strap supplied with the panel. For non-service entrance (sub- panel) applications, the panel may be installed with the bonding strap not connected to the neutral. Separate ground bars must be used on non-service entrance panels. Insulated/Bondable Single Neutral Panels are supplied with a single insulated neutral. For service entrance applications, all that is required to bond the neutral is to loosen the bonding screw and the neutral screw directly beside it, insert the bonding strap into the neutral bar, and re- tighten both connections. The single neutral can be moved by the contractor to the other side of the panel, if desired. When used as a service entrance panel, unused neutral connections may be used for the termination of equipment grounds. For non- service entrance (sub-panel) applications, the panel may be installed with the bonding strap not connected to the neutral. Separate ground bars must be used on non-service entrance panels. Grounds In service entrance applications where the neutral is bonded, unused neutral holes may be used for terminating ground conductors. In sub-feed panels, the neutral must be isolated (non-bonded), and ground wires must be terminated on a separate ground bar. The insulated/bondable single/split neutral panels have sufficient terminations for both ground and neutral conductors. The insulated/ bondable single split neutral panels are supplied with a separate factory-installed ground bar if the catalog number contains a “G.” If not, a separate ground bar should be installed. Insulated/ Bondable Single Neutral panels are supplied without a ground bar (unless otherwise noted), and ground bar kits if needed must be purchased separately. Neutral and Ground Terminals The standard terminals on grounds and neutrals are rated to accept (3) #14–#10 Cu/Al or (1) #14–4, provided the cables terminated are of the same material. For larger cables, add-on neutral lugs may be ordered from the accessories on Page V1-T1-65. Note: NEC allows only one current-carrying conductor per hole on neutrals unless otherwise noted. Bottom Fed Loadcenters For single-phase 225 A and below loadcenters that are bottom fed, a standard panel can be rotated 180 degrees to allow straight-in wiring of power cables to the main terminals. Because the main circuit breaker handle operates horizontally, the orientation of the main circuit breaker handle is consistent with the requirements of NEC 2008 Article 240.81. Gutter Splicing Loadcenters are not UL listed as wiring troughs. Therefore, gutter splicing of riser cables to tap off to the main device is not permitted. Refer to NEC 2008 Article 312.8. Fire Rating Due to the numerous openings in both loadcenter boxes and trims, they should not be mounted in firewalls. There is no approved method for sealing the enclosures for this application. Date Code The date of manufacture of each loadcenter is printed on the outside of the carton as well as inside the loadcenter. On the carton, the date code is printed on the end carton label. In the loadcenter, the date code is located on the small white label located on the right side wall (with the main device on top). The date code is in the following format: F # # # &. The “F” is the numeric code for the Lincoln, IL plant, and the three numbers are the year and week of manufacturing, e.g., 023. The “!” sign at the end signifies the decade of the 2010. Therefore, the date code F023& would indicate that the product was manufactured in the 23rd week of 2010. The 1980s are represented by the “+” sign and the 1990s are represented by a “=” at the end of the code. Surge Protectors Complete home surge protection is available in multiple options, including a factory-installed option that provides the highest level of surge protection in a residential design. See Tab 3 for more details. Circuit Breaker Case Interrupting Capacity ●10 kAIC ●22 kAIC ●25 kAIC Warranty Information ●10-year limited loadcenter warranty ●10-year limited branch breaker warranty V1-T1-44 Volume 1—Residential and Light Commercial CA08100002E—September 2014 www.eaton.com 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1.2 Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers Type BR Loadcenter Warranty 10-year warranty on all Type BR loadcenters and circuit breakers. Single Keyhole Mounting One keyhole at the top and bottom provides easier mounting and leveling Neutral Bus (Strap) Is easily removable for sub-panel applications Bonding Z-Strap Provides easy field conversion for service entrance applications Twin Neutral Bars Minimum 150% neutral capacity Steel Backpan Provides solid and reliable breaker mounting—single piece design for stability and durability Extra 1.5 inch Knockout (38.1 mm) Larger knockout provides easier installation and time savings “Tangential” Center Knockout Easier installation for conduit applications Commercial Grade Main Breaker 25 kAIC series rated main breaker for superior protection 2/0 Lug Easily removable and can be installed in any location on the neutral bar Drywall Marking on Enclosure Indicates proper mounting depth for flush applications Standard Tin-Plated Aluminum Bus Excellent conductivity and corrosion resistance Copper bus options available for select catalog numbers Type BR AFCI Breakers Compact design for easier wiring and improved wireway access Optional LED indicates one of six trip codes for circuit diagnostics Provides a clean gutter space Top or Bottom Feed Straight-in wiring saves labor and material One panel for either top or bottom applications ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ Volume 1—Residential and Light Commercial CA08100002E—September 2014 www.eaton.com V1-T1-45 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1.2Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers Standards and Certifications UL Listings All Eaton Type BR loadcenters are listed under UL File E52977 except the 2–8 circuit loadcenters, up through and including 125 A, which are listed under UL File E8741. Catalog Number Selection Single- and Three-Phase Through 600 A Note 1 No character space used. 3 BR 30 42 B C 200 Phase Blank = Single-phase 1 3 = Three-phase Construction Blank = No feed thru lugs 1 F = Feed-through lugs G = Ground bar P = Current design NY = NY City gutter space Number of 1-Inch (25.4 mm) Spaces Factory Options SUR = Factory integrated surge Eaton’s Type BR Loadcenter Maximum Number of Circuits Bus Blank = Aluminum bus 1 C = Copper bus Main Device B = Main breaker L = Main lug N = Convertible main H = Main breaker high AIC Enclosure R = NEMA Type 3R rainproof S = NEMA Type 1 indoor with surface trim F = NEMA Type 1 indoor with flush trim Blank = NEMA Type 1 indoor with combination trim 1 RIS = Riser panel Amperes 50 = 50 A 70 = 70 A 100 = 100 A 125 = 125 A 150 = 150 A 200 = 200 A 225 = 225 A 300 = 300 A 400 = 400 A 600 = 600 A V1-T1-70 Volume 1—Residential and Light Commercial CA08100002E—September 2014 www.eaton.com 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1.2 Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers Technical Data and Specifications General A. The Contractor shall furnish and install deadfront loadcenters incorporating circuit breakers of the number, rating and type as specified herein and as shown on the contract drawings. B. The loadcenter and all components shall be designed, manufactured and tested in accordance with the latest applicable standards of UL, NEMA and NEC including: 1. UL 67—Standards for Panelboards. C. UL 50—Standards for Cabinets and Boxes. D. UL 489—Standards for Molded Case Circuit Breakers. E. UL 869—Standards for Service Equipment. F. Federal Specification W-C 375B—Circuit Breakers. G. Federal Specification W-C P115b—Panel Power Distribution Type 1, Class 2. Qualifications A. The manufacturer of the loadcenter shall be the manufacturer of the circuit breaker within the loadcenter. B. For the equipment specified herein, the manufacturer shall be ISO 9000 certified. C. The manufacturer of this equipment shall have produced similar electrical equipment for a minimum period of seven (7) years. Manufacturers A. Eaton. Ratings A. Loadcenters shall be rated for 120/240 Vac and shall have short-circuit ratings as shown on the drawings or as herein scheduled, but not less than 10,000 amperes rms symmetrical. B. Circuit breakers shall be a minimum of 125 A frame. Circuit breakers 15 through 125 A trip size shall take up the same pole spacing. C. Loadcenters shall be labeled with a UL short- circuit rating. When series combination ratings are applied with integral or remote upstream devices, a label shall be provided. Series combination ratings shall cover all trip ratings of installed frames. It shall state the conditions of the UL series ratings including: 1. Size and type of upstream device. 2. Branch devices that can be used. 3. UL series short circuit rating. Construction A. All interiors, with the exception of the branch circuit breakers, shall be completely factory assembled with main breakers, main lugs, or no main device. B. Interiors shall be designed so that circuit breakers can be replaced without disturbing adjacent units and without removing the main bus connectors and shall be designed so that circuits may be changed without machining, drilling, or tapping. C. Physical means shall be provided to prevent the installation of more overcurrent devices than that number for which the enclosure was designed, rated and approved. Half-size breakers shall have a UL listed rejection tab over the line terminals. Loadcenter interiors must have notched stabs to accept these rejection tab class CTL breakers, if required and approved. Bus A. Busbars for the main and cross connectors shall be [tin-plated aluminum] [copper] in accordance with Underwriters Laboratories standards. Busing shall be braced throughout to conform to industry standard practice governing short-circuit stresses in loadcenters. Note: Note to spec writer— select one (copper available in limited ratings). B. Neutral busing shall have a suitable lug for each outgoing feeder requiring a neutral connection of same ampacity as branch. Wiring/Termination A. All wire connectors and terminals shall be of the anti-turn solderless type and shall be suitable for copper or aluminum wire of the sizes indicated. All connectors must meet the “Requirements for Wire Connectors and Soldering Lugs” as stated in UL 486B. B. All loadcenters where marked shall be suitable for use with 60 °C or 75 °C rated wire. Circuit Breakers A. Circuit breakers shall be molded case type. Circuit breakers shall have four-rivet construction (GFI Type— 5 rivets). Multipole circuit breakers shall be of a stack pole design to provide electrical phase isolation. B. Each pole of the circuit breaker will provide inverse time delay overload and instantaneous short- circuit protection by means of both thermal and magnetic sensors. C. The circuit breaker calibration shall not be affected by environmental changes in relative humidity. The thermal bimetal element shall be welded to the steel frame and calibration shall be set independent of the molded case by computer controlled equipment. D. All circuit breakers shall be operated by a toggle-type handle and multipole circuit breakers shall have an internal common trip mechanism. The circuit breakers shall incorporate trip mechanisms that are mechanically trip-free from the handle. The handle position shall provide visual trip indication. E. Contacts shall be of non-welding silver alloy. F. All circuit breakers shall have the trip rating inscribed on the handle on each circuit breaker pole. Also, unique color- coded cases that indicate the UL listed 10 kA or 22 kA interrupting ratings. Breakers shall be able to be used as main or branch disconnect devices. Volume 1—Residential and Light Commercial CA08100002E—September 2014 www.eaton.com V1-T1-71 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1.2Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers G. Branch circuit breakers may also be used in the 1/2-inch (12.7 mm) per pole ratings that include two-pole 1-inch (25.4 mm) wide modules and four-pole 2-inch (50.8 mm) wide modules. Two-pole circuit breakers must incorporate a common trip mechanism. The exclusive CTL rejection tab feature shall be provided to limit the number of branch devices for a loadcenter to 42, in compliance with NEC Article 384.15. H. Circuit breakers shall be completely enclosed in a molded case of thermoset material. No internal aluminum parts shall be used. All internal ferrous parts shall be plated to prevent corrosion. I. All terminals shall be listed for use with copper or aluminum conductors. Terminals shall be of the box lug or clamp type design. The terminals shall meet UL 486B requirements and shall be suitable for use with either 60 °C or 75 °C wire. J. The calibrated bimetal assembly shall be mechanically isolated from the load terminal using a flexible braided copper shunt wire, such that movement of the terminals due to twisting and overtorquing does not affect breaker calibration. K. Breakers shall be SWD rated and/or HACR rated as required. L. Arc Fault Interrupting circuit breakers, (AFI), shall be provided on all 15 and 20 A single-phase 120/240 Vac circuits except those indicated as remote controlled breakers. AFI breakers shall be “Classified for mitigating the effects of arcing faults,” or conforming to UL Standard 1699 and as defined by Article 210.12 Section A of the 1999 NEC Code. Surge Protection Devices See Volume 1, Tab 2 for complete details on surge protection. Enclosures A. Loadcenter shall have NEMA Type 1 general purpose or NEMA Type 3R rainproof enclosures as indicated on the drawings and shall be surface or combination flush/surface mounted except where noted. B. Boxes shall be made from galvanized sheet steel having multiple knockouts. Rainproof boxes shall use galvanized steel or an approved coating system which meets or exceeds standards for outdoor NEMA Type 3R enclosures. Boxes shall be of sufficient size to provide at least a minimum code gutter space on all sides. C. The deadfront shall have an easy adjustment feature for flush applications. D. Boxes shall be factory assembled into a single rigid structure. E. Unless otherwise noted on drawings, hinged doors covering all circuit breaker handles shall be included in all trims. Trim doors shall not uncover any live parts in making the circuit breaker handles accessible. If key locks are required, all locks shall be keyed alike. F. Combination trims for flush and surface panels shall be flat and shall overlap the box by at least 5/8-inch (15.9 mm) all around. Trims shall be mounted by a screwdriver without the need for special tools. Finish A. Trims shall be bonderized and finished with a light gray ANSI-61 enamel. The paint finish shall be of a type to which field applied paint will adhere. Factory Testing A. The standard factory tests shall be performed on the equipment provided under this section. All tests shall be in accordance with the latest version of UL and NEMA. Volume 1—Residential and Light Commercial CA08100002E—September 2014 www.eaton.com V1-T1-49 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1.2Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers Single-Phase—Main Lug Loadcenters Single-Phase Three-Wire—120/240 Vac—Insulated/Bondable Split Neutral, continued Notes 1 Ground bar kits priced separately unless otherwise noted. See Page V1-T1-65. 2 Has notch for BREQS125 hold-down kit. 3 Single, movable neutral is provided. 4 Combination cover style. 5 Suitable for use as service equipment when not more than six main disconnecting means are provided and when not used as a lighting and appliance panelboard (see Article 408.34 of the NEC). 6 Ground bars GBK5 and GBK520 installed. 7 Rainproof panels are furnished with hub closure plates. For rainproof hubs, refer to Page V1-T1-65. 8 Ground bar GBK1220 installed. 9 Has notch for BRHDK125 hold-down kit. j Includes through-feed lugs for both phase and neutral conductors. Main Ampere Rating Maximum Number 1-Inch (25.4 mm)Enclosure Type Box Size Wire Size Range Cu/Al 60 °C or 75 °C for Main Lugs Loadcenter Catalog Number with Combination or NEMA Type 3R Cover 1Spaces Circuits 125 12 12 Indoor B1 #6–2/0 BR1212L125 2345 12 24 Indoor B1 BR1224L125 245 12 24 Indoor B1 BR1224L125G 245 12 24 Indoor B1 BR1224L125DG 2456 12 24 Outdoor B1R BR1224L125R 257 16 16 Indoor B2 BR1616L125 245 16 24 Indoor B2 BR1624L125 24 16 24 Indoor B2 BR1624L125G 24 16 24 Outdoor B2R BR1624L125R 27 20 20 Indoor C1 BR2020L125 245 20 24 Indoor C1 BR2024L125 24 20 24 Indoor C1 BR2024L125G 248 20 24 Outdoor C1R BR2024L125R 27 24 24 Indoor C2 BR2424L125 24 24 24 Indoor C2 BR2424L125G 248 30 42 Indoor D1 BR3042L125 24 150 16 30 Indoor C2 #1–300 kcmil BR1630L150 49 20 30 Indoor C2 BR2030L150 49 200 8 16 Outdoor B2R #1–300 kcmil BR816L200RF 57j 12 24 Indoor B2 BR1224L200 459 12 24 Outdoor B2R BR1224L200R 579 20 40 Indoor C2 BR2040L200 49 20 40 Indoor C2 BR2040L200G 489 20 40 Outdoor C3R BR2040L200R 79 24 40 Indoor C4 BR2440L200 49 30 40 Indoor D1 BR3040L200 49 30 40 Indoor D1 BR3040L200G 489 30 40 Outdoor D1R BR3040L200R 79 40 40 Indoor G1 BR4040L200 49 40 40 Indoor G1 BR4040L200G 49 40 40 Outdoor G1R BR4040L200R 79 225 42 42 Indoor L1 #1–300 kcmil BR4242L225 4 42 42 Outdoor L1R BR4242L225R 7 BR1224L125 BR1224L200 Volume 1—Residential and Light Commercial CA08100002E—September 2011 www.eaton.com V1-T1-27 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1.1Loadcenters and Circuit Breakers Type CH Loadcenters and Circuit Breakers Field Installation Rainproof Conduit Hubs Ground Bar Kits Ground Bar Legend Grounded “B” Phase Adapters Neutral Bar Accessories Notes 1 Must be purchased in multiples of ordering quantities indicated. 2 Distance between mounting holes is 1-3/4 inches (44.5 mm). 3 For single- and three-phase 400A loadcenters. 4 Distance between mounting holes is 2-13/32 inches. 5 Cannot be used in Safety Breaker Panels. Classic Plus Panels only. Description Conduit Size Ordering Quantity 1 Catalog NumberInches (mm) Group 1—for use with 70, 100 and 125A MLO and MCB loadcenters and circuit breaker enclosures, and the following 150 and 200A panels: CH8B150RF, CH8B200RF 0.75 (19.1) 1 DS075H1 1.00 (25.4) 1 DS100H1 1.25 (31.8) 1 DS125H1 1.50 (38.1) 1 DS150H1 2.00 (50.8) 1 DS200H1 Group 2—for use with 150, 200 and 225A MLO and MCB loadcenters and circuit breaker enclosure except for the following 150 and 200A panels: CH8B150RF, CH8B200RF 2.00 (50.8) 1 DS200H2 2.50 (63.5) 1 DS250H2 3.00 (76.2) 1 DS300H2 Adapter kit—allows Installing a Group 1 hub on devices arranged for Group 2 hubs — 1 DS900AP Group 1—small blank hub closure plate — 1 DS900CP1 Group 2 —þlarge blank hub closure plate — 1 DS900CP2 Description (See Legend) Length Ordering Quantity 2 Catalog NumberInches (mm) dssssds dssssdsj dssssdssssss dssssdssssssj dssssdssssssssss dssssdssssssssssj dssssdsssssssssssssssss dssssdsssssssssssssssssj ssssssssdssssssdsssssss 2.54 (64.5) 1 GBK5 2 3.59 (91.2)1 GBK520 2 4.29 (109.0)1 GBK10 2 5.34 (135.6)1 GBK1020 2 4.61 (117.1)1 GBK13 2 5.69 (144.5)1 GBK14 2 6.74 (171.2)1 GBK1420 2 8.14 (206.8)1 GBK21 2 9.19 (233.4)1 GBK2120 2 7.94 (201.7)1 CH9GP21 34 DS100H1 GBK14 fdfffkfdfkfffkfs j d = (3) #14–#10 Cu/Al or (1) #14–#4 Cu/Al = (1) #6–2/0 Cu/Al = (1) 1/0–14 or (3) #10–12 Cu/Al = (1) #14–1/0 Cu/Al or (3) #14–#10 Cu/Al = Mounting holef kMaximum Amperes Three-Phase Loadcenter Types of Panels Kit Catalog Number 5 125 12–32 circuit main lug CHGRD1 225 Main lug and CHH main breaker panels CHGRD2 CC main CB panels CHGRD3 Description Catalog Number 5 Split neutral kit for 22 circuit 125A maximum CHSN125C Split neutral kit for 32 circuit 200A maximum CHSN225J Split neutral kit for 42 circuit 200A maximum CHSN225K Replacement neutral for all C type boxes CHN125C Replacement neutral for all D type boxes CHN125D Replacement neutral for all L type boxes CHN225L Isolated Neutral Assembly (computer circuits)BINA V1-T1-76 Volume 1—Residential and Light Commercial CA08100002E—September 2014 www.eaton.com 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1.2 Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers Product Selection Plug-On Circuit Breakers, Types BR—10/22/42 kAIC, 120 Vac, 120/240 Vac and 240 Vac Type BR Breakers, 1-Inch (25.4 mm) per Pole 120/240, 10, 22 and 42 kAIC Notes 1 One pole, 1-inch (25.4 mm) per pole circuit breakers are available with high magnetic setting for switching large tungsten lamp loads. Add suffix H to catalog number. 2 Switching duty rated. 3 On the black handle breaker, add suffix “B” to the catalog number to obtain a tapped molded opening for proper use with hold-down kits. 4 For use as a branch circuit breaker in 400 and 600 ampere panels only. All Type BR single-, two- and three-pole circuit breakers carry listing for HACR application. For circuit breakers with a shunt trip, add ST suffix. Ampere Rating Wire Size Range Cu/Al 60 °C or 75 °C Single-Pole 120/240 Vac Requires One 1-Inch (25.4 mm) Space Two-Pole 120/240 Vac Common Trip Requires Two 1-Inch (25.4 mm) Spaces 10 per Shelf Carton 5 per Shelf Carton 10 kAIC 22 kAIC 10 kAIC 22 kAIC 42 kAIC 65 kAIC Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number Catalog Number 10 #14–4 BR110 — BR210 — — — 15 #14–4 BR115 12 BRH115 BR215 3 BRH215 — — 20 #14–4 BR120 12 BRH120 BR220 3 BRH220 — — 25 #14–4 BR125 BRH125 BR225 3 BRH225 — — 30 #14–4 BR130 BRH130 BR230 3 BRH230 — — 35 #14–4 BR135 BRH135 BR235 3 BRH235 — — 40 #14–4 BR140 BRH140 BR240 3 BRH240 3 —— 45 #14–4 — BRH145 BR245 3 BRH245 — — 50 #14–4 BR150 BRH150 BR250 3 BRH250 3 —— 55 #14–3 BR150 BRH155 BR255 BRH255 — — 60 #8–1/0 BR160 BRH160 BR260 BRH260 BRHH260 BRX260 70 #8–1/0 BR170 BRH170 BR270 BRH270 BRHH270 BRX270 80 #8–1/0 — — BR280 BRH280 BRHH280 BRX280 90 #8–1/0 — — BR290 BRH290 BRHH290 BRX290 100 #8–1/0 — — BR2100 BRH2100 BRHH2100 BRX2100 110 #8–1/0 — — BR2110 BRH2110 BRHH2110 BRX2110 125 #4–2/0 — — BR2125 BRH2125 BRHH2125 BRX2125 150 #4–2/0 — — BR2150 4 ——— BR120 BR215 BR320 BRH2100 BRX2125 1 1.2Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers BR Circuit Breakers BR Circuit Breakers Product Description . Plug-On Combination Type Arc Fault Circuit Breakers, Type BR—10 kAIC, 120 Vac and 120/240 Vac A combination type arc fault circuit interrupter is a device that includes all of the protection offered by the branch feeder AFCI (mitigation of high current arcing faults in the complete circuit, including connected cords). In addition it provides direct detection of persistent low current arcing faults down to 5 amps with associated mitigation of fire hazards in the cords connected to the outlets. High current arcing faults can occur from line to neutral or line to ground. These arcing faults are in parallel with the load and produce the most energy of all arcing faults. The current level of low current arcing faults is limited by the load. Plug-On Combination Type Arc Fault Circuit Breakers, Type BR—10 kAIC, 120 Vac and 120/240 Vac BRCAF115 Type BR, 1-Inch (25.4 mm) wide FIRE-GUARD Combination Type AFCI Circuit Breakers Poles Ampere Rating Configuration Catalog Number Single-pole 10 kAIC 15 AFCI BRCAF115 1 Diagnostic AFCI BRACAF115 20 AFCI BRCAF120 1 Diagnostic AFCI BRACAF120 Single-pole 22 kAIC 15 AFCI BRHCAF115 1 20 AFCI BRHCAF120 1 Two-pole 10 kAIC 15 AFCI BRL215CAF 20 AFCI BRL220CAF