HomeMy WebLinkAboutLecesse O and Ms - Division 31… Approved … Approved as Noted … Revise as Noted/Resubmit … Rejected/Resubmit as Specified … No Action Required … Submittal Not Requested/Returned without Review Approval is only for general conformance with the design concept of the Project and the information given in the Contract Documents. Contractor is responsible for dimensions to be confirmed and correlated at the job site; information that pertains solely to the fabrication process or to the means and methods of construction; coordination of the work of all trades; and performing all work in a safe and satisfactory manner. This approval does not modify Contractor’s duty to comply with the Contract Documents. Reviewed by:_______________ Date:_________ x DLE 10/23/14 1. PROCTOR IN THIS SUBMITTAL IS FOR ON- SITE MATERIAL, WHICH IS A PREVIOUSLY IMPORTED SAND & GRAVEL. SEE NOTE 4 ON S101 RE: USE OF ON-SITE MATERIAL UNDER BUILDINGS/DRIVES. 2. THE MAX DENSITY WAS ADJUSTED UPWARD DUE TO THE 21% RETAINED ON THE 3/4" SIEVE. IF THE ACTUAL MATERIAL USED IN THE FIELD DOES NOT HAVE THIS AMOUNT OF LARGE AGGREGATE IN IT (21% BETWEEN 2" & 3/4"), IT WILL BE DIFFICULT TO ACHIEVE 95% OF THE ADJUSTED DENSITY. COMMENTS Ph : 585-334-4490 75 Thruway Park Drive West Henrietta, NY 14586 14-0298 Stone Quarry Apartments 400 Spencer Road Ithaca, NY Submittal Revision No: Sent Date: 334000.2 Submittal No: Spec Section No:Job: Required From Sub: Approved By Architect: 10/20/14 Spec Section Title:Sirk Submittal Title:Storm Sewer Structures PD/SD Subcontractor: Primary Contact: Phone Number: Supplier/Manufacturer: If this box is checked this submittal may differ from the plans and specs. Notes: Subcontractor Stamp LECESSE Stamp Architect/Engineer Stamp LECESSE Construction Services LLC General Contractor: I HAVE PERSONALLY REVIEWED THIS SUBM ITTA L AND IN MY ESTIMATION THIS DOCUMENT FULFILLS THE INTENT OF THE PLANS AND SPECIFICATIONS AND IS APPROVED FOR SUBM ISSION. LECESSE CONSTRUCTION SERVICES LLC BY: Drew JohnsonJason Socola Mark Curran DDS Constructors 585-340-0500 Earthwork EPS Geofoam PD 312323-1.3 11/6/14 R1 Product data attached. Shop dwgs to follow. Approved Approved as Noted Revise as Noted/Resubmit Rejected/Resubmit as Specified No Action Required Submittal Not Requested/Returned without Review Approval is only for general conformance with the design concept of the Project and the information given in the Contract Documents. Contractor is responsible for dimensions to be confirmed and correlated at the job site; information that pertains solely to the fabrication process or to the means and methods of construction; coordination of the work of all trades; and performing all work in a safe and satisfactory manner. This approval does not modify Contractor’s duty to comply with the Contract Documents. Reviewed by:_______________ Date:_________ X DLE 11/10/14 L E T T E R O F T R A N S M I T T A L DATE 11/ 3/ 14 JOB N O. ATTENTION TO LeCesse Construction Re: Stone Quarry Apartments 75 Thruway Park Drive West Henrietta, NY 14586 Emai Deliver Pick-up Fax Overnight WE ARE SENDING YOU Attached Under Separate Cover Prints Reductions Specifications Submittals Correspondence Change Order Other COPIES DATE DWG. NO. DESCRIPTION LAST REV. 1 11/ 3/ 14 Underslab Geofoam THESE ARE BEING TRANSMITTED (AS CHECKED BELOW): For Approval For Your Use For Approval Signature Returned For Review and Comment As Requested Other : COPY TO SI GN ED Mark Curran – Project Manager DDS Constructors, LLC DDS CONSTRUCTORS 45 Hendrix Road West Henrietta, NY 14586 (585) 340-0500 office (585) 359-7541 fax CONTROL, NOT COMPROMISE.® Copyright © 2010 AFM Corporation. All rights reserved. Printed in USA. Foam-Control, Perform Guard, and Control, Not Compromise are registered trademarks of AFM Corporation, Lakeville, MN. www.geofoam.com Foam-Control EPS Geofoam is a cellular plastic material that is strong, but has very low density (1% of traditional earth materials.) It is a manufactured in block form and meets ASTM D6817, “Standard Specification for Rigid, Cellular Poly- styrene Geofoam.” Ready to Use. Foam-Control EPS Geofoam maximizes onsite installa- tion efficiency: material arrives ready to place, no weather delays. Quality Assurance. Foam-Control EPS Geofoam meets or exceeds the requirements of ASTM D6817, “Standard Speci- fication for Rigid, Cellular Polystyrene Geo- foam.” Foam-Control EPS is monitored for Quality Control and Listed by Underwriters Laboratories Inc. Size and Shape. Foam-Control EPS Geofoam is produced in block form and is easily positioned at the work site. Standards sizes: 4’ (1.2 m) widths 8’ (2.4 m) up to 16’ (4.8 m) lengths 1” (25 mm) to 36” (914 mm) thickness Other sizes and fabrication can be provided by the manufacturer. Design. For most applications, long-term design loads should not ex- ceed the linear elastic range of Foam-Control EPS Geofoam. Combined live and dead load stresses should not exceed the compressive resistance at 1% strain. Additional Information. Please consult the Foam-Control EPS Geofoam TechData which provides additional information, design consider- ations, and technical information on the full range of EPS Geofoam materials available. Please also refer to ASTM D6817, ASTM D7180, and ASTM D7557. Foam-Control EPS Geofoam with is available to provide protection against termites. GEOFOAM 1 Please refer to UL certificate for complete information. Foam-Control EPS Geofoam Properties Density, min. ASTM C303 lb/ft 3 (kg/m3) 1.8 0 (28.8) Compressive Resistance @ 1% deformation, min. ASTM D1621 psi psf (kPa) 10 .9 1570 (75) Elastic Modulus, min. ASTM D1621 psi (kPa) 10 9 0 (7500) Flexural Strength, min. ASTM C203, Procedure B psi (kPa) 50.0 (345) Buoyancy Force lb/ft 3 (kg/m3) 60.6 (970) Water Absorption by total immersion, max., volume % ASTM C272 2.0 R-value Thermal Resistance per 1.0 in. thickness ASTM C518 25o F o F.ft 2.h/ Btu (oK.m 2/W) 5.0 (0.88) 40 oF o F.ft 2.h/ Btu (oK.m 2/W) 4.8 (0.84) 75 oF o F.ft 2.h/ Btu (oK.m 2/W) 4.4 (0.77) Flame Spread Index1 Smoke Developed Index1 ASTM E84/UL723 20 15 0 - 3 0 0 Oxygen Index, min., volume % ASTM D2863 24 Additional Properties for Compressible Applications Compressive Resistance @ 5% deformation, min. ASTM D1621 psi psf (kPa) 24.7 3560 (170) Compressive Resistance @ 10% deformation, min. ASTM D1621 psi psf (kPa) 29.0 4180 (200) TYPE EPS29 T ECH D ATA Under-slab Insulation SIPs Foam face-off: Choosing Foam-Control EPS with Perform Guard over XPS, Polyiso, and untreated EPS. Foam-Control EPS with Perform Guard is recognized in an ICC ES report as termite resistant and others are not Meets ICC ES AC239 requirements for termite resistance foam plastic Suitable for use in all areas of termite risk Meets requirements of IBC Section 2603.8 Meets requirements of IRC Section 320.5 CONTROL, NOT COMPROMISE.® Foam-Control ® EPS with Perform Guard® Prevent damage to your insulation and preserve your structural integrity and R-value. Foam-Control EPS with Perform Guard is a termite resistant expanded polystyrene insulation for all types of construction. It is used in Structural Insulated Panels (SIPs), Perimeter and Under-slab Foundation Insulation, Exterior Insulation and Finish Systems (EIFS), Geofoam, Insulated Concrete Forms (ICFs), and other EPS Building Products and Systems. Meets code requirements for ground contact use Resistant to termite damage Incorporates EPA registered additive Safe for handling and noncorrosive Insulation helps keep people comfortable. Unfortunately, insulations are susceptible to termite infestation. Foam-Control EPS with Perform Guard is an important component in preventing this problem. It’s made by a process that incorporates a termite resistant additive into the insulation during the manufacturing process. The addi- tive is registered with the Environmental Protection Agency (EPA) for this application. Foam-Control EPS with Perform Guard has been thoroughly tested, is safe for handling, and noncorrosive. And termites hate it. Proven to meet, or exceed, building codes. Foam-Control EPS is manufactured to Quality Control Program standards monitored by Un- derwriters Laboratories Inc. and recognized by national building codes. Foam-Control EPS manu- facturers offer product warranties that ensure thermal performance, physical properties, and ter- mite resistance. Foam-Control EPS with Perform Guard has been evaluated for below grade use by the ICC ES and meets ICC ES AC239 requirements. Please see ICC ES ESR-1006. Foam-Control EPS can stand up to all industry tests— and has. No other EPS can say that. CONTROL YOUR MATERIALS. CONTROL YOUR LIABILITY. CONTROL YOUR RISK. CONTROL YOUR PERFORMANCE. CONTROL YOUR L INTEGRITY. DON’T COMPROMISE YOUR R-VALUE. DON’T COMPROMISE YOUR STRUCTURE. DON’T COMPROMISE YOUR REPUTATIO Under-slab InsulationPerimeterWall Sheathing Insulating Concrete Forms SIPs * Perform Guard is not a barrier, but should be used in conjunction with a total Pest Management Program available from a reputable Pest Control Operator. Problem. Termites love to live, work, and eat in comfortable and pro- tected surroundings. All untreated insulations can poten- tially provide this environment. Most of the U.S. is susceptible to termite activity. It is important that insulation products and systems account for the potential of termite infestation. Termites reduce insulation & system performance Termites cause problems for structural systems Costs to control termites can continue indefinitely Test ing. AFM Corporation has conducted extensive research to: find an effective additive that would deter termites, develop processes for the incorporation of the additive into EPS, and "test prove" and "field prove" the efficacy of the Foam-Control EPS with Perform Guard. Termite exposure tests have been conducted by industry recognized institutions following industry recognized test standards of ICC ES AC239. Product performance test- ing has shown how Foam-Control EPS with Perform Guard resists termite infestation when installed following our recommendations. Termite Infest at ion Risk. Applications. Foam-Control EPS with Perform Guard must be used in conjunction with Do-All-Ply® to ensure optimum perfor- mance. Do-All-Ply was specifically developed for use with Foam-Control EPS with Perform Guard insulation. Do-All-Ply is used to adhere Foam-Control EPS with Perform Guard to substrates and fill board joints. Foam-Control EPS with Perform Guard is a termite resistant insulation. Foam-Control EPS with Perform Guard is not a barrier system, but should be used in conjunction with a total insect management program available from a repu- table pest control operator. Ready to take control? Start here. If you’re starting to wonder how Foam-Control EPS with Perform Guard can contribute to your next project, here’s how to find out: Just contact your nearest Foam-Control EPS manufacturer. They’ll be happy to give you a de- sign consultation, information about Foam-Control EPS products, pricing, and the answers to all your questions. Contact a sales rep and download Foam-Control EPS docu- mentation at www.foam-control.com. Termite Damaged Untreated Foams Foam-Control EPS products are manufac- tured by AFM Corporation licensees. Copyright © 2010 AFM Corporation. All rights reserved. Printed in USA. Control, Not Compromise, Foam-Control EPS and Perform Guard are trademarks of AFM Corporation, Lakeville, MN. ICC ES logo is a registered trademark of ICC Evaluation Service, Inc. UL logo is a registered trademark of Underwriters Laboratories Inc. FM logo is a registered trademark of Fac- tory Mutual/FM Global. PG01-04-10-E CONTROL, NOT COMPROMISE.® TM Jason Socola Approved Approved as Noted Revise as Noted/Resubmit Rejected/Resubmit as Specified No Action Required Submittal Not Requested/Returned without Review Approval is only for general conformance with the design concept of the Project and the information given in the Contract Documents. Contractor is responsible for dimensions to be confirmed and correlated at the job site; information that pertains solely to the fabrication process or to the means and methods of construction; coordination of the work of all trades; and performing all work in a safe and satisfactory manner. This approval does not modify Contractor’s duty to comply with the Contract Documents. Reviewed by:_______________ Date:_________ X DLE 11/18/14 REVIEWED SUBMITTAL INCLUDES THE RESUBMITTED GEOFOAM LAYOUT;COPY ATTACHED.NOTE THAT INDIVIDUAL BLOCK DIMENSIONS TOACCOMODATE THE REQUIRED PLANDIMENSIONSARE THE RESPONSIBILITYOF THE CONTRACTOR AND WERE NOTREVIEWED. REFERENCES100AND S101 FORFNDNPLAN DIMENSIONS. s\SEE REVISED SHEET ATTACHED REVISED REVISED *PER MANUFACTURER'S RECOMEDNATION, GRIPPER PLATES ARE NOT REQUIRED. 9'-57/8"FROM INSIDE FACEOF CMU FNDN WALL TO STEP 5'-0" 14'-57/8" 13'-10" 18'-10 3/8" 8'-11 5/8" 13'-10" 18'-10 3/8" TYPE EPS29 -REF PRODUCT SUBMITTAL NOTE:DIMENSIONS TOSTEPS BASED ONREINFORCING STEEL SUBMITTAL,WHICH PROVIDES THEPRECISE STEP LOCATIONS. OTHER PLAN DIMENSIONS TOBETAKEN FROMTHE CONTRACT DRAWINGS S100 AND S101. Approved Approved as Noted Revise as Noted/Resubmit Rejected/Resubmit as Specified No Action Required Submittal Not Requested/Returned without Review Approval is only for general conformance with the design concept of the Project and the information given in the Contract Documents. Contractor is responsible for dimensions to be confirmed and correlated at the job site; information that pertains solely to the fabrication process or to the means and methods of construction; coordination of the work of all trades; and performing all work in a safe and satisfactory manner. This approval does not modify Contractor’s duty to comply with the Contract Documents. Reviewed by:_______________ Date:_________ X DLE 11/18/14 NOTE -DETAILED BLOCK DIMENSIONS NOTREVIEWED OTHERTHAN OVERALL FILL THICKNESS REQUIREMENTS NOTE -DETAILED BLOCK DIMENSIONS NOTREVIEWED OTHERTHAN OVERALL FILL THICKNESS REQUIREMENTS