Loading...
HomeMy WebLinkAboutLecesse O and Ms - Division 231 LECESSE CONSTRUCTION The Power of Partnership Job: 14-0298 Stone Quarry Apartments 400 Spencer Road Ithaca, NY Spec Section Title: HVAC Submittal Title: Exhaust Fan PD Subcontractor: Kennedy Mechanical 75 Thruway Park Drive West Henrietta, NY 14586 Ph : 585-334-4490 Submittal Primary Contact: Darren Englert Phone Number: 585-232-2800 Supplier/Manufacturer: If this box is checked this submittal may differ from the plans and specs. Notes: Submitted for Owner approval General Contractor: LECESSE Construction Services LLC Spec Section No: 230000-3 Submittal No: Revision No: RO Sent Date: 1212- 14 Required From Sub: 10/20/14 Approved By Architect: • Subcontractor Stamp LECESSE Stamp I HAVE PERSONALLY REVIEWED THIS SUBMITTAL AND IN MY ESTIMATION THIS DOCUMENT FULFILLS THE INTENT OF THE PLANS AND SPECIFICATIONS AND IS APPROVED FOR SUBMISSION. LECESSE CONSTRUCTION SERVICES LLC BY: Jason Socola Architect/Engineer Stamp oiymayi,eu uy xuu i•eyuv�u> Scott Reynolds DN: cn=Scott Reynolds, o=Ithaca Neighborhood Housing Senvices, Inc, ou, email=sreynolds@ithacanhs.org, [=US Date: 2014.12.04 05:41:09 -05'00' EP -1 Mms-r F -rws is �' deet VENTILATION a FAN Specification Submittal Data / Panasonic Ventilation Fan Description Customizable Ventilation Fan/Light shall be low sone ceiling mount rated for continuous run. Fan shall be ENERGY STAR® rated and certified by the Home Ventilating Institute (HVI). Fan shall include energy efficient LED lighting. Evaluated by Underwriters Laboratories and conform to both UL and cUL safety standards. Motor/Blower: • Enclosed DC brushless motor technology rated for continuous run. • Fan ventilation rates shall be manually adjustable for 50-80-110 CFM. • Power rating shall be 120 volts and 60 Hz. • Fan shall be UL listed for tub/shower enclosure when used with a GFCI protected circuit and used in insulated ceiling (I TPE I.C.). • Fan equipped with thermal cutoff fuse. • Removable, permanently lubricated, plug-in motor. Housing: • Rust proof paint, galvanized steel body. • Integrated dual 4" or 6° diameter duct adapter. • Built-in metal flange provides blocking for penetrations through drywall as an Air Barrier, and assists with the decrease in leakage in the Building Envelope during blower door testing. • Built in backdraft damper. • Articulating and expandable installation bracket up to 24°. Grille: • Attractive design using Poly Pro material. • Attaches directly to housing with torsion springs. • Includes a motion sensor cap for use as a cover when the motion sensor Plug 'n PlayT"" module has not been selected. Light: (2) 7W GU24 base • Two replaceable, ENERGY STAR® rated, 7W GU24 LED lamps included. base LED lamps Warranty: • ALL Parts: 3 Years from original purchase date. DC Motor: 6 Years from original purchase date. LED: 5 years from original purchase date. Archkectural Specifications: Customizable Ventilation Fan/Light shall be ceiling mount, ENERGY STAR® rated type with multi -speed control (0, 30-100 CFM, in 10 CFM increments) that shall be built-in with a high/low adjustable delay timer and activated by a wall switch, Motion Sensor Plug 'N PIayT"" module or Condensation Sensor Plug 'N Play'' module. Features a built-in speed selector. Select from 50/80/110 CFM and no more than <0.31<0.3/0.4 sone as certified by the Home Ventilating Institute (HVI) at 0.1 w.g. with no less than 53/86/114 CFM and no more than <0.3/0.6/0.9 sones at .25 w.g. Power Consumption shall be no greater than 4.0/6.0/11.1 watts at 0.1 w.g. and 7.0/11.1/18.0 watts at 0.25 w.g. ENERGY STAR® rated with efficiency of no less than 12.8/13.3/9.9 CFM/watt at 0.1 w.g. and than 7.7/7.7/6.3 CFM/watt at 0.25 w.g. The motor shall be enclosed with brushless DC motor engineered to run continuously. DC motor speed shall automatically increase when the fan senses static pressure to maintain selected CFM. Power rating shall be 120v/60Hz. Duct diameter shall be no less than 4°, inclusive of an integrated dual 4' or 6" duct adapter. Plug 'N PlayTM' modules provide up to two additional features. Select from Condensation Sensor, LED Night Light and Motion Sensor. Fan shall be UL and cUL listed for tub/shower enclosure when used with a GFCI protected circuit. Fan can be used to comply with ASHnAE 62.2, LEED, ENERGY STAR®, IAP, EarthCraft, California Title -24 and WA Ventilation Code. Lamps shall be of the LED type with the fan utilizing no less than two 7 Watt, ESTAR rated, GU24 base LED lamps. DC Motor Technology: When fan senses static pressure, its speed is automatically increased to ensure that the desired CFM is not compromised, which allows the fan to perform as rated. For complete Installation Instructions visit us.panasonic.com/ventfans Adjustable Airflow for Maximum Performance FV -05-1 1 VKSL1 FV -05-11 VKSL1 Model / Quantity 35 (EF -1) 14 Comments project: Stone Quarry Built in Speed Control for Location: Ithaca, NY FV-05-11VKSL1 v Replaced FV-08VKSL3 i High and Low CFM Adjustment Architect: HOLT Supplied with Night Light Engineer: HOLT Module # FV-NLVK1 and Contractor: Kennedy Mechanical PC-RDO5C4 Radiation Damper Submitted by: Herman HVAC Products Date: 11/11/14 VENTILATION 5 FAN Plug 'N PIayTM Modules Adjustable Airflow for Maximum Performance FV -05-1 1 VKSL1 ✓ Plug 'N Play- modules provide up to two features (multi -speed is already built-in to FV-05-11VKSL1). Select from Motion Sensor, Condensation Sensor and LED Night Light. szl FV VS15VK1: Multi -Speed with Time Delay - N/A for this Fan, already built-in. Allows you to select the proper CFM settings to satisfy ASHRAE 62.2 continuous ventilation requirements. The fan runs continuously at a pre-set lower level (0, 30-100 CFM, in 10 CFM increments), then elevates to a maximum level of operation (50-80-110 CFM) when the wall switch is turned on, or when the motion sensor or Condensation Sensor module is activated. A High/Low delay timer returns the fan to the pre-set CFM level after a period of time set by the user. FV MSVK1: Motion Sensor Automatically activates when someone enters the room. Once the settings have been applied, the fan becomes truly automatic. This module also activates a 20 minute delay off timer for the fan. FV-CSVK1: Condensation Sensor Helps control bathroom condensation to prevent mold and mildew. Sensor technology detects relative humidity and temperature to anticipate dew point, automatically turning the fan on to control humidity. Built-in Relative Humidity (RH) sensitivity adjustment enables fine tuning for moist conditions and for satisfying CaiGreen requirements. When the condensation sensor is used in conjunction with multi -speed functionality, the fan will kick up to high speed when the condensation sensor detects moisture in the room. This module also activates a 20 minute delay off timer for the fan. Fi/=NIlWKh: LED Night Light A photocell automatically turns on the 1 watt LED night light when darkness is sensed in the room. High/Low brightness switch enables you to fine tune the photocell to work in conjunction with the darkness level of your bathroom. This module also activates an automatic 20 minute delay off timer for the fan. Fan Specifications Static Pressure in inches w.g. 0.1 0.25 0.1 0.25 0.1 WYisperGreen 0.25 0.1 0.25 SelectT"': 0.1 FV-05-11VKSL1 0.25 0.1 0.25 0.1 0.25 0.1 0.25 0.1 025 Air Volume (CFM) 110 114 100 105 90 94 80 86 70 71 60 62 50 53 40 43 30 35 Noise (sones) 0.4 0.9 <0.3 0.8 <0.3 0.6 <0.3 0.6 <0.3 0.4 <0.3 0.3 <0.3 <0.3 <0.3 <0.3 <0.3 <0.3 Power Consumption (watts) 11.1 18.0 8.7 15.0 7.0 12.8 6.0 11.1 4.7 8.9 3.9 7.6 4.0 7.0 2.8 5.7 2.5 5.0 Energy Efficiency (CFM/Watt) 9.9 6.3 11.6 7.1 13.1 7.5 13.3 7.7 15.3 8.2 15.9 8.4 12.8 7.7 14.6 7.7 12.8 7.4 Speed (RPM) 960 1237 926 1213 872 1184 837 1157 796 1119 769 1102 740 1081 739 1077 731 1058 Current (amps) 0.12 0.17 0.09 0.15 0.08 0.13 0.07 0.12 0.05 0.09 0.05 0.08 0.04 0.07 0.04 0.06 0.03 0.06 MAX. Current (amps) 0.42 Power Rating (V/Hz) - 120/60 ENERGY STAR rated Yes Panasonic Eco Solutions Company of North America Eco Products Division Two Riverfront Plaza Newark, NJ 07102 us.panasonic.com/ventfans l.^V)c(:)- 1 0.25=Installed Performance BEIME wwmenapyna..ew Most Efficient 2014 Panasonic VF13189SS - 08VQL6 7y/��spe VENT/LAT/ON FAN EF -1 LF BTHs Specification Submittal Data / Panasonic Ventilation Fan Description Ventilating fan shall be Low Noise ceiling mount type rated for continuous operation. Fan shall be ENERGY STAR rated and certified by the Home Ventilating Institute 0-1V1). Fan shall include energy efficient compact fluorescent lighting. Evaluated by Underwriters Laboratories and conform to both UL and cUL safety standards. Motor/Blower: • Four -pole totally enclosed condenser motor rated for continuous operation. • Power Rating shall be 120 volts and 60 Hz. • Fan shall be UL and cUL listed for tub/shower enclosure when used with a GFCI protected circuit and used in insulated ceiling (TYPE I.C.) • Motor equipped with thermal -cutoff fuse. • Removable with permanently lubricated plug-in motor. Housing: • Rust proof paint, galvanized steel body. • Detachable dual 4° or 6" diameter duct adaptor. • Built-in metal flange provides blocking for penetrations through drywall as an Air Barrier, and assists with the decrease in leakage in the Building Envelope during blower door testing. • Built in backdraft damper. • Double hanger bar system allowing for ideal positioning. • Expandable extension bracket up to 24'. GriUe: • Attractive design using PP material. • Attaches directly to housing with torsion springs. Light: • Two 13Watt self -ballasted GU24 base compact fluorescent lamps included. • One 4 -Watt night -light included. • FCC Part 18 compliant. Warranty: • ALL Parts: For period of 3 years from the date of the original purchase. Compact Fluorescent Lamps (CFL):1 year. Night Light Lamp: No Warranty. Architectural Specifications: Ventilation fan and light shall be of the ceiling mount, ENERGY STAR rated type, with no less than 80 CFM and no more than <0.3 sone as certified by the Home Ventilating Institute (HVI) at 0.1 static pressure in inches water gauge (w.g.) with no less than 62 CFM and no more than 0.4 sone as certified by HVI at .25 w.g. Power Consumption shall be no greater than 14.9 watts at 0.1 w.g. and 14.7 watts at 0.25 w.g. and ENERGY STAR rated with efficiency of no less than 5.5 CFM/watt at 0.1 w.g. and 4.3 CFM/ watt at 0.25 w.g. The motor shall be totally enclosed, four pole condenser type engineered to operate continuously. Power rating shall be 120v/60Hz. Included is an Integrated dual 4' or 6° diameter duct adaptor. Duct diameter shall be no less than 4°. Fan shall be UL and cUL listed for tub/shower enclosure when used with a GFCI protected circuit. Fan can be used to comply with ASHRAE 62.2, LEED, ENERGY STAR IAP, EarthCraft, California Title -24 and WA Ventilation Code. Lamps shall be of the compact fluorescent type and utilize no less than two 13 Watt self-baflasted GU24 base ESTAR rated compact fluorescent lamps. Night -light feature shall be included. (2) 13W self - ballasted GU24 base CFL lamps included Specifications: WhisperLite FV-08VQL6 4" or 6" Duct (Standard) Ventilation Fan Characteristics (HVI tested data for 0.1" S.P.) Static Pressure in inches w.g. 0.1 Radiation Damper j Architect: HOLT Air Volume (CFM) 80 62 Noise (sones) <0.3 0.4 Power Consumption (watts) 14.9 14.7 Energy Efficiency (CFM/Watt) 5.5 4.3 Speed (RPM) 863 1117 Current (amps) 0.12 0.12 Power Rating (V/Hz) 120/60 ENERGY STAR rated YES 0.25=Installed Performance For complete Installation Instructions visit us.panasonic.com/ventfans FV o8VQL6 ✓ FV-08VQL6 o, 0.60 3 m0.50 t a 0.40 u 0.30 0.20 0.10 0.00 0 Performance Curve 4° or 6' duct i FV -013V01.6 --•20 Feat 40 Feet ----80 Feet 100 Feet 20 40 60 80 100 Airflow(CFM) Model Quantity Comments I Project: Stone Quarry FV-08VQL6 21 (EF -2) V Supplied with PC-RDO5C4 Location: Ithaca, NY Radiation Damper j Architect: HOLT Engineer: HOLT Contractor: Kennedy Mechanical Submitted by: Herman HVAC Products Date: 11/11/14 Panasonic Eco Solutions North America Eco Products Division Two Riverfront Plaza Newark, NJ 07102 us.panasonic.com/ventfans MEtvt) CONUS Panasonic e F-3 NbN-DWELL1, b U MTs v f#is1ve Specification Submittal Data / Panasonic Ventilation Fan Description Ventilating fan shall be Low Noise ceiling mount type rated for continuous operation. Fan shall be ENERGY STAR rated and certified by the Home Ventilating Institute (HVI). Evaluated by the Underwriters Laboratories and conform to both UL and cUL standards. Motor/Blower: • Four -pole totally enclosed condenser motor rated for continuous use. • Power Rating shall be 120 volts and 60 Hz. • Fan shall be UL and cUL listed for tub/shower enclosure when used with a GFCI branch circuit wiring. • Motor equipped with thermal -cutoff fuse. • Removable with permanently lubricated plug-in motor. Housing: • Rust proof paint, galvanized steel body. • Detachable dual 4" or 6° diameter duct adaptor. • Built in backdraft damper. • Expandable extension bracket up to 24". • Double hanger bar system allowing for ideal positioning. Grille: • Attractive design using PP material. • Attaches directly to housing with torsion springs. Warranty: • ALL Parts: For period of 3 years from the date of the original purchase. Architectural Specifications: Ventilating fan shall be of the ceiling mount, ENERGY STAR rated type, with no less than 80 CFM and no more than less than <0.3 sone as certified by the Home Ventilating Institute (I -MM) at 0.1 static pressure in inches water gauge (w.g.) with no less than 62 CFM and no more than 0.4 sone as certified by HV1 at 0.25 w.g. Power Consumption shall be no greater than14.7 watts at 0.1 w.g. and 14.5 watts at 0.25 w.g ENERGY STAIR rated with efficiency of no Tess than 5.8 CFM/watt at 0.1 w.g and 4.5 CFM/watt at 0.25 w.g. The motor shall be totally enclosed, four pole condenser type engineered to operate continuously. Power rating shall be 120v/60Hz. Included is a detachable dual 4° or 6° diameter duct adaptor. Duct diameter shall be no less than 4°. Fan shall be UL and cUL listed for tub/ shower enclosure when used with GFCI branch circuit wiring. Fan shall be ASHRAE 62.2, LEED, ENERGY STAR IAP, EarthCraft, California Title -24, and WA Ventilation Code compliant. Specifications: WhisperCeiling FV-08VQ5 4" or 6" Duct (Standard) Ventilation Fan Characteristics (HVI tested data for 0.1" S.P.) Static Pressure in inches w.g. 0.1 0.25 Air Volume (CFM) 80 62 Noise (sones) <0.3 0.4 Power Consumption (watts) 14.7 14.5 Energy Efficiency (CFM/Watt) 5.8 4.5 Speed (RPM) 829 1089 Current (amps) 0.12 0.12 Power Rating (V/Hz) 120/60 ENERGY STAR rated YES As of date 4/11 For complete Installation Instructions visit www.panasonic.com/building FV -08V05 ✓ FV-08VQ5 oil 0.60 2 0.50 0.40 0.30 0.20 0.10 0.00 O 20 40 60 80 100 Airflow(CFM) 4" Duct FV -08V05 - __20 Feet ^^^••^40 Feet --60 Feet - - 80 Feet - •100 Feet 6" Duct Model Quantity Comments Project Stone Quarry FV-08VQ5 '� 2 (EF -3) Supplied with PC-RDO5C4 Radiation Damper Location: Ithaca, NY Architect: HOLT Engineer: HOLT Contractor: Kennedy Mechanical Submitted by: Herman HVAC Products Date: 11/11/14 Panasonic Home and Environment Company Division of Panasonic Corporation of North America One Panasonic Way Secaucus, NJ 07094 www.panasonic.com/bullding NIIIcaus VF11076SS-08 Panasonic Specification Submittal Data Panasonic Radiation Damper for Ventilation Fans Description: Radiation damper shall be assembled with select ENERGY STAR® rated ventilation fans, fan/lights and fans with motion/humidity sensors. Damper shall be UL and cUL listed for T -bar, hanger rod/ wire ceiling installation and exceed UL 555C for use in 3 -hour fire rated floor/ceiling or roof/ceiling assemblies. Radiation shall be Warnock -Hersey certified for use in wood frame floor/ceiling and roof/ceiling assemblies. Damper shall exceed National Fire Protection Agency NFPA-90A. Features: • UL listed and exceeds UL 555C for use in a 1, 2, or 3 hour fire -rated floor -ceiling and roof ceding designs. • Warnock -Hersey classified for wood frame assemblies. • 165 degree Fahrenheit fusible link. • High-temperature, non -asbestos, reinforced fiber thermal fabric. • Galvanized steel frame. Fie 4: 3225-1598:100 Warnock Hemcuy Fie #: W W -495 -PSH -0177, -0178 UL listed assembly with Panasonic ENERGY STAR models: • WhisperGreena • WhisperGreen-Lite' • WhisperCeiling'" • WhisperLite® • WhisperSense " • VVhisperSense-Ute" • WhisperWelcome" • WhisperFit" • WhisperValue" C0US Re*: R16724 PC-RDO5C4 PC-RDO5C4 For complete Installation Instructions visit www panasonic.com/building ModelQuantity Comments Project: Stone Quarry PC-RDO5C4 58 Ceiling Radiation Dampers For EF -1, EF -2 & EF -3 Location: Ithaca, NY Architect: HOLT Engineer: HOLT Contractor: Kennedy Mechanical Submitted by: Herman HVAC Products Date: 11/11/14 Panasonic Eco Solutions North America Eco Products Division One Panasonic Way Secaucus, NJ 07094 www.panasonic.com/building VF12199SS Panasonic AIR-COOLED CONDENSING UNIT SCHEDULE DESIGN EQUIPMENT 5 YORK YCJF48S41S2 i 0 f 0 E 0 f iN E' OUTSIDE, AS INDICATED OUTSIDE, AS INDICATED f J >> > > co 0 Z > Z Q W W I 0 ( UW a) < O -J za W 0o > C/)LL ~ Q Z JWO 7-2 YF 1,7) d WO y J = J 0 r 0 z o Z j 0 ro ~ LL 9 O LL W Z OOQ< W W Z OETO Z O Qco 0 S S co0 PANASONIC FV-05-11VKSL FAN SCHEDULE 20 a0 3 0 o< o'a G GG 0 x F� 2 EPT HALF -BATHS 00 `z 3 c 0 AIR TERMINAL SCHEDULE Ph : 585-334-4490 75 Thruway Park Drive West Henrietta, NY 14586 14-0298 Stone Quarry Apartments 400 Spencer Road Ithaca, NY Submittal Revision No: Sent Date: 334000.2 Submittal No: Spec Section No:Job: Required From Sub: Approved By Architect: 10/20/14 Spec Section Title:Sirk Submittal Title:Storm Sewer Structures PD/SD Subcontractor: Primary Contact: Phone Number: Supplier/Manufacturer: If this box is checked this submittal may differ from the plans and specs. Notes: Subcontractor Stamp LECESSE Stamp Architect/Engineer Stamp LECESSE Construction Services LLC General Contractor: Ph : 585-334-4490 75 Thruway Park Drive West Henrietta, NY 14586 14-0298 Stone Quarry Apartments 400 Spencer Road Ithaca, NY Submittal Revision No: Sent Date: 334000.2 Submittal No: Spec Section No:Job: Required From Sub: Approved By Architect: 10/20/14 Spec Section Title:Sirk Submittal Title:Storm Sewer Structures PD/SD Subcontractor: Primary Contact: Phone Number: Supplier/Manufacturer: If this box is checked this submittal may differ from the plans and specs. Notes: Subcontractor Stamp LECESSE Stamp Architect/Engineer Stamp LECESSE Construction Services LLC General Contractor: Features • 7 Day, 5-2 Day or Non-Programmable • Large 5 Sq. In. Display with Bright Blue Backlight • Auto or Manual Changeover • SpeedBar Multi-Function Button • Adjustable Temperature Limits • Indoor or Outdoor Remote Sensing • SpeedSet Programming Mode • Meets Energy Aware® Guidelines* • Hardwire or Battery Powered • Multi-Level Keypad Lockout • Separate User and Installer Reset Buttons • Programmable Fan with On or Auto Modes • Adaptive Recovery Mode (ARM ) • Temporary Override Limits • Residential and Commercial Modes • Compatible with 2 or 3 Wire Hydronic Zone Systems • English / Spanish Packaging and Instruction Card 5020 Single Stage Conventional or Heat Pump Programmable or Non-Programmable Thermostat ® ® TM 5 Y EAR WARRANTYLIMITED Toll-Free 866.268.5599 (U.S.) +1.630.844.1968 (Outside the U.S.) PREMIER SERIES ACTUAL SIZE TM ® FREE Contractor Branding! Visit braeburnonline.com *As a licensee in the Energy Aware Programmable Thermostat Program, Braeburn Systems LLC has determined that this product meets the NEMA Energy Aware efficiency specifications for programmable thermostats. Visit www.getenergyaware.com for more information. Architectural Specifications The universal auto changeover thermostat shall be a Braeburn® model number 5020, 3.86” high x 5.11” wide x 1.42” deep, powered with either 24 Volt AC or with two “AA” Alkaline batteries (3.0 Volt DC). In the event of a power failure, the unit shall retain all user, installer and program settings. The thermostat shall be compatible with low voltage single stage gas, oil, or electric heating or cooling systems, and single stage heat pump systems. Also compatible with 250mv – 750mv millivolt heating only systems and 2 or 3 wire hydronic zone systems. The thermostat shall have a bright blue backlight display, SpeedBar®, separate sub-base and multi-level keypad lockout. Temperature control range shall be between 45° and 90° F (7° and 32° C), accuracy of +/- 1° F (+/- .5° C) and operating humidity range between 5% and 95% relative humidity. The thermostat shall include separate installer and user setup modes, permanent non-volatile memory to retain user settings, filter, UV and humidifier pad check monitor, adaptive recovery mode (ARM™), programmable fan mode, residual cooling fan delay and indoor or outdoor remote sensor capability. A front reset button will return user settings to default values when pressed. Meets California Title 24 and Energy Aware® Guidelines. ©2012 Braeburn Systems LLC • 5020-300-04 Product Specifications Dimensions: 3.86” x 5.11” x 1.42” Electric Rating: 24 Volt AC (18-30 Volt AC) 1 amp maximum load per terminal 3 amp total maximum load (all terminals) AC Power: 18-30 Volt AC DC Power: 3.0 Volts DC (2 “AA” Alkaline batteries included) Compatibility: Single stage gas, oil or electric systems Single stage heat pump systems 250mv – 750mv millivolt heating systems Control Range: 45° to 90° F (7° to 32° C) Display Range: 40° to 99° F (5° to 37° C) Accuracy: +/- 1° F (+/- .5° C) Temperature Differential: .5°, 1°, or 2° F (0.2°, 0.5°, or 1° C) Storage Temperature: 14° to 140° F (-10° to 60° C) Operating Humidity: 5% to 95% Relative Humidity Terminations: Rc, Rh, O/B/V3, Y1, W1, G, C, S1, S2 Accessories 2950 Universal Wall Plate (6.5” x 6.5” x .125”) 5970 Universal Thermostat Guard Shipping Information INDIVIDUAL CARTON MASTER CARTON Dimensions: 5.0” x 6.3” x 2.0” Quantity: 6 Weight: .92 lbs. Dimensions: 6.4” x 13” x 5.6” Cubic Feet: .27 Weight: 6 lbs. Braeburn 5020 Replaces* Honeywell® TH6110 White-Rodgers® 1F85-0471, 1F87-361, 1F97-0671 *Verify specific application requirements. All trademarks are the property of their respective owners. FREE Contractor Branding Available! Visit our website (www.braeburnonline.com) for more information, contact your local distributor or call our sales department toll-free at 866.268.5599 (U.S.), +1.630.844.1968 (Outside the U.S.). Terminal Designations Rc Rh O/B/V3 Y1 W1 G C S1 S2 Cooling Transformer Date: _____________________________________________ Job Name: _________________________________________ Location: __________________________________________ Contractor: ________________________________________ Engineer: __________________________________________ Model No.: _________________________________________ Submitted By: ______________________________________ Submitted For Approval: ___________ Record: ___________ Fan Control Transformer CommonReversing Valve or Zone Valve Power Close Remote Sensor (Indoor or Outdoor) 5390 Remote Indoor Sensor 5490 Remote Outdoor Sensor Braeburn Systems LLC • 2215 Cornell Avenue • Montgomery, IL 60538 • Toll-Free 866.268.5599 (U.S.) +1.630.844.1968 (Outside the U.S.) Heating Transformer Heat Control Cool Control ® Ph : 585-334-4490 75 Thruway Park Drive West Henrietta, NY 14586 14-0298 Stone Quarry Apartments 400 Spencer Road Ithaca, NY Submittal Revision No: Sent Date: 334000.2 Submittal No: Spec Section No:Job: Required From Sub: Approved By Architect: 10/20/14 Spec Section Title:Sirk Submittal Title:Storm Sewer Structures PD/SD Subcontractor: Primary Contact: Phone Number: Supplier/Manufacturer: If this box is checked this submittal may differ from the plans and specs. Notes: Subcontractor Stamp LECESSE Stamp Architect/Engineer Stamp LECESSE Construction Services LLC General Contractor: Jason Socola ✔ cbaMatch Siding Color where Louver is installed 02-10-15 APT F1 399' - 6" APT F2 408' - 10 5/8" APT TOW426' - 4 3/8" APT F3 418' - 3 1/4" D7 A301 APT TOH LOW427' - 10 3/8" A7 A301 A1 A301A1 A311 A5 A311 A8 A311 K J H G F E D C B A E E E H H A A A E D D C G G A F A A A E BB B B A APT TOH HIGH 429' - 4 3/8" C A 1' - 6"1' - 6"8' - 1 1/8"9' - 4 5/8"9' - 4 5/8"VSV.2 VSH.2 VSH.5 VSH.5 VSH.3 VSH.4 VSH.6 VSH.6 VSH.6 VSH.3 VSH.2 VSH.4 VSH.3 VSH.6 VSH.6 VSH.2 VSH.2 VSV.2 VSH.3 VSV.2 VSH.6 VSH.6 VSH.2 VSV.2 LTM.1 CP5.1 CP5.1CP5.1 LTM.1 LTM.1 LTM.1 CP3.1 VSV.2 ICP.M VSV.2 VSH.5 VSF.1 LTD.1 LTM.1 JC.MJC.M ICP.M VSF.1 LTM.1LTM.1CP3.MCP3.MLTD.1LTM.1LTM.1JC.MCP3.MCP3.M ICP.M ICP.MVSH.3 VSF.1VSH.3 VSF.1 VSF.1CP3.MCP3.MCP3.MCP3.M ICP.M ICP.MCP5.1CP5.1VSH.6CP5.1 ICP.M ICP.MCP3.MCP3.MCP3.1CP3.M ICP.M ICP.MJC.MJC.MLTM.1LTD.1LTM.1JC.MLTM.1VSH.4VSH.3 VSF.1 VSF.1 VSF.1LTM.1CP5.1CP5.1 ICP.MCP3.1 ICP.MCP3.MLTM.1 VSF.1VSH.3 VSF.1JC.MCP3.MCP3.MJC.MCP3.1 VSF.1B B E7 A504 APT F1399' - 6" APT F2408' - 10 5/8" APT TOW426' - 4 3/8" APT F3 418' - 3 1/4" APT TOH LOW427' - 10 3/8" A1 A312 A5 A312 A8 A312 E E E G C C F F F C C C A A APT TOH HIGH429' - 4 3/8" ENTRY WALK 4' - 0" ENTRY PLANTER 18' - 0"15' - 4" 3' - 6"53' - 10"4' - 0"39' - 10"12' - 0"10' - 0"3' - 6" 6" x 6" PT POST (2) 2x12 CEDAR BOARDS, THROUGH BOLT TO EACH SIDE OF POST 10" DIMENSIONAL ALUMINUM SIGNAGE NOTE: FINISH - CABOTS CLEAR WOOD PROTECTOR FOUNDATION DETAIL SIMILAR TO F5/L603 TYPICAL 4' FENCE, REFER TO L603 25' - 0" 13' - 0" EXTEND FENCE POST UP VSH.3 VSH.3 VSV.2 VSH.4 VSH.3 VSH.6 VSH.2 VSH.2 VSV.2 2120 2219 CP3.MJC.MJC.MJC.MCP5.1CP5.1 ICP.MLTM.1LTM.1LTM.1CP3.M VSF.1CP5.1VSH.6LTM.1 VSF.1LTM.1LTM.1VSH.4LTM.1 VSF.1VSH.6 VSF.1LTM.1CP5.1VSH.4 ICP.MLTM.1VSH.3 VSF.1CP5.1VSH.3 ICP.MVSH.6 ICP.MCP5.1CP5.1 ICP.MVSF VINYL SOFFIT VSV VINYL SHEET VERTICAL CP3 CORNERPOST - 3 1/3" CP5 INSIDE CORNERPOST - 3/4"ICP LINEAL TRIM, MITER CORNER - 5"LTM LTD LINEAL TRIM, DOUBLE CHANNEL - 5" CORNERPOST - 5" SIDING TYPES ABBREVIATIONS VSF VINYL SOFFIT - TRIPLE 2" VENTED SOFFIT VSV VINYL SIDING VERTICAL - SINGLE 8" VERTICAL BOARD AND BATTEN VSH VINYL SIDING HORIZONTAL - RESTORATION CLASSIC DOUBLE 4" CLAPBOARD TRIM TYPES ABBREVIATIONS 2 LIGHT MAPLE 3 AUTUMN RED4 PACIFIC BLUE5 6 SABLE BROWN MOUNTAIN CEDAR COLOR TYPES NOTE: TRIMS WITH "M" DESIGNATION SIGNIFY COLORMATCH WITH ADJACENT FRONT FACE. 1 SAVANNAH WICKER JC J-CHANNEL - 1" A B C D E F G A B C D E F G 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 WARNING: It is a violation of New York State Law for any person, unless acting under the direction of a licensed Architect, to alter this document in any way. If a document bearing the seal of an Architect is altered, the altering Architect shall affix to such document his seal and the notation "altered by" followed by his signature, the date of such alteration, and a specific description of the alteration. Architecture Planning Interior Design 217 North Aurora Street Ithaca NY 14850 p 607.273.7600 f 607.273.0475 DATE: PROJECT: OTHER: DRAWN BY:7/18/2014 5:01:29 PMA201 APARTMENT BUILDING EXTERIOR ELEVATIONS 7/18/2014 ITHACA, NYSTONE QUARRY APARTMENTS, LLCSTONE QUARRY APARTMENTS2012059 Author 3/16" = 1'-0"D2 APARTMENT BUILDING - WEST 3/16" = 1'-0"A4 APARTMENT BUILDING - SOUTH REVISION SCHEDULE NAME DATE Internal View Width and Height furnished approximately 0.250 in. under size. ESD-202 2 in. Frame Application & Design ESD-202 is a weather louver designed to protect air intake and exhaust openings in building exterior walls. Design incorporates a drainable head member and stationary horizontal blades to channel water to the jambs which guides the water through vertical downspouts for escape at the sill. The ESD-202 is an extremely efficient louver with AMCA LICENSED PERFORMANCE DATA enabling designers to select and apply with confidence. Construction Features Frame Depth (in.):2Frame Thickness (in.): 0.063 Louver Material:Aluminum Frame Type:Channel Sizing:Nominal Fixed Blade Thick. (in.):0.063 Shape:Rectangular Welded Construction:No Options and Accessories Finish Louver Finish Type: Kynar 70% (2 coat)Louver Finish Color: Standard TBS BirdScreen Bird Screen: Internal Bird Screen Mat'l:AluminumBird Screen Type: 3/4x0.050 Flat Exp. Bird Screen Finish:Match Louver Warranty Product Warranty:1 Yr (Standard)Finish Warranty: 10 Yrs (Standard) Summary ID #Tag Qty.W (in.)H (in.)Free Area (ft2)Sect. Wide Sect. High Sect. Ship 1-1 2 18.000 8.000 0.23 1 1 2 Larger openings may require field assembly of multiple louver panels to make up the overall opening size. Individual louver panels are designed to withstand windloads up to a maximum of 25PSF (size and configuration dependent). Design, materials and installation of structural reinforcement required to adequately support large sections or multiple section assemblies within a large opening are not provided by Greenheck. Unless specifically indicated, the following are NOT included in the quote provided: structural steel, installation hardware (anchors, angle clips, continuous angles, shims, fasteners, inserts, backer rod and sealant), field measuring and/or installation, miscellaneous flashing, trim or enclosures, blank off panels, mullion covers or mullion hardware, hinged frames or removable subframes, custom bird/insect screen, 3-coat, metallic and/or exotic paint finishes, bituminous paints for unlike metals, any applicable taxes, stamped and sealed structural calculations seismic calculations or job specific engineered submittal drawings. 11/6/2014Printed Date: Stone Quarry 7-17-14Job: LouversMark: CAPS 4.15.1679 P:\CAPS Files\Stone Quarry 7-17-14.gfcj Page 2 of 6 Louvers Product Limited Warranty Thank you for purchasing Greenheck louvers. Greenheck warrants this equipment to be free from defect in material and workmanship for a period of 1 year from the date of product shipment. Any units or parts, which prove defective during the warranty period, will be repaired or replaced at our option when returned to our factory, transportation prepaid. Unless agreed upon otherwise Greenheck will not be held responsible for costs associated with removal or installation of product(s). The legal remedies described in this Limited Warranty are the sole exclusive remedy of Customer. This limited warranty will be void if payment from Customer is not received within a commercially reasonable time frame. GREENHECK MAKES NO OTHER WARRANTY, EITHER EXPRESS OR IMPLIED, REGARDING ITS PRODUCTS, OR ITS SELECTION AND APPLICATION, INCLUDING, BUT NOT LIMITED TO, COMPLIANCE WITH BUILDING CODES, SAFETY CODES, LAWS, MERCHANTABILITY OR FITNESS OR A PARTICULAR PURPOSE. This limited warranty is extended solely to the Customer. It is nontransferable and non-assignable, and the Customer shall not permit or authorize its employees, agents, representatives or customers to claim, represent or imply that this limited warranty extends or is available to anyone other than the Customer. In the event of material breach by the Customer of any of the conditions of this warranty, Greenheck shall have no liability for and product failure claims. Failure to pay Greenheck in full for original services will automatically make this warranty null and void. Greenheck will not be held liable for incidental or consequential damages of any kind. The limited warranty of product(s) replaced or repaired under this limited warranty shall be limited to the remainder of the original warranty period. Greenheck reserves the right to reasonable field access to diagnose and repair any product alleged to be defective. This limited warranty may not be modified by anyone and may not be changed by such things as purchase order forms or acceptance forms, unless otherwise agreed upon by Greenheck. This limited warranty is provided in lieu of any other warranty requirements or obligations, including, but not limited to, those within project specifications. All notices and claims given under or pursuant to this agreement shall be in writing and sent by certified or registered mail, postage prepaid, return receipt requested to: Greenheck, Attn: Louver Sales, 525 Western Road, Schofield, WI 54476. By proceeding to use our products and services on your project, you accept the terms of these limited warranties. 11/6/2014Printed Date: Stone Quarry 7-17-14Job: LouversMark: CAPS 4.15.1679 P:\CAPS Files\Stone Quarry 7-17-14.gfcj Page 3 of 6 Louvers Architectural Finish Limited Warranty Kynar/Hylar and Mica (70% PVDF) PaintGreenheck warrants the finish of Kynar/Hylar (70% PVDF) paint for a period of 10 years from the date of productshipment when applied to aluminum louvers or aluminum architectural products. Greenheck warrants that for 10 yearsafter the date of product shipment the applied finish:A)Will not chip, crack or peel (lose adhesion) but does not include minute fracturing, which may occur inproper fabrication of building parts.B)Will not chalk in excess of ASTM D-4214-89 number 8 rating, determined by the procedure outlined inASTM D-4214-89 specification test.C) Will not change color more than five (5) Delta-E Hunter units (square root of the sum of Delta L, Delta Aand Delta B) as determined by ASTM method D-2244. It is acknowledged that fading or color changesmay not be uniform if the surfaces are not equally exposed to the sun and elements. Metallic and Mica colors are exempt in the warranty from item C but will hold the L value within 5 Delta E or the L scale ofthe Hunter E unit system. Exotic colors will receive a full 10 year warranty if they have the recommended clear coat applied. However, Exotic colorsare excluded from the 20 year warranty. Any units or parts, which prove defective during the warranty period, will be repaired or replaced at our option whenreturned to the factory, transportation prepaid. Unless agreed upon otherwise Greenheck will not be held responsible forcosts associated with installation or removal of product(s). Greenheck limited warranties are not applicable when failure is caused by events that cannot be controlled by Greenheck.These include, but are not limited to, Acts of God, fire or other casualty or physical damage; Government restrictions; Actsof aggression; Harmful fumes or foreign substances in the atmosphere; Improper storage or packaging of the parts priorto installation; Product failure due to improper usage and/or application; Failure to provide reasonable and routinemaintenance and/or improper maintenance, including, but not limited to the use of chemical cleaning agents not inaccordance with AAMA recommendations or failure to use a systematic maintenance cleaning program in areas of highsalt concentration; Corrosive atmosphere found in the interior of buildings, which effect the interior surface of material;Standing or ponding water on the metal; Excessive building movements; Work performed or materials supplied by others;Improper treatment of finished material; Corrosion of the metal substrate; Incompatibility between materials, including, butnot limited to, Galvanic corrosion due to contact with adjacent dissimilar metals such as stainless steel; Damage to thepainted metal occasioned by moisture or other contamination detrimental to the finish because of improper storage of thefinished metal prior to installation as outlined in AAMA Publication 10, “Care and handling of Architectural Aluminum FromShop to Site." The legal remedies described in this Limited Warranty are the sole exclusive remedy of Customer. This limited warrantywill be void if payment from Customer is not received within a commercially reasonable time frame. GREENHECKMAKES NO OTHER WARRANTY, EITHER EXPRESS OR IMPLIED, REGARDING ITS PRODUCTS, OR ITSSELECTION AND APPLICATION, INCLUDING, BUT NOT LIMITED TO, COMPLIANCE WITH BUILDING CODES,SAFETY CODES, LAWS, MERCHANTABILITY OR FITNESS OR A PARTICULAR PURPOSE. This limited warranty isextended solely to the Customer. It is nontransferable and non-assignable, and the Customer shall not permit orauthorize its employees, agents, representatives or customers to claim, represent or imply that this limited warrantyextends or is available to anyone other than the Customer. In the event of material breach by the Customer of any of the conditions of this warranty, Greenheck shall have no liabilityfor and product failure claims. Failure to pay Greenheck in full for original services will automatically make this warranty null and void. Greenheck will not be held liable for incidental or consequential damages of any kind. The limited warranty of product(s)replaced or repaired under this limited warranty shall be limited to the remainder of the original warranty period.Greenheck reserves the right to reasonable field access to diagnose and repair any product alleged to be defective. Thislimited warranty may not be modified by anyone and may not be changed by such things as purchase order forms oracceptance forms, unless otherwise agreed upon by Greenheck. This limited warranty is provided in lieu of any other warranty requirements or obligations, including, but not limited to,those within project specifications. All notices and claims given under or pursuant to this agreement shall be in writing and sent by certified or registered mail,postage prepaid, return receipt requested to: Greenheck, Attn: Louver Sales, 525 Western Road, Schofield, WI 54476. By proceeding to use our products and services on your project, you accept the terms of these limited warranties. 11/6/2014Printed Date: Stone Quarry 7-17-14Job: LouversMark: CAPS 4.15.1679 P:\CAPS Files\Stone Quarry 7-17-14.gfcj Page 4 of 6 VCD-23 Low Leakage Control Damper Application & Design The VCD-23 is a ruggedly built low leakage control damper intended forapplication in low to medium pressure and velocity systems. A wide range ofelectric and pneumatic actuators are available. RATINGSPressure: 5 in. wgVelocity: 3,000 ft/minLeakage: Class 1A @ 1 in. wg, Class 1 @ up to 5 in. wg. Installation instructions available at www.greenheck.com. H W 5 1.25 Max. Notes: All dimensions shown are in units of inches. W & H furnished approximately 0.25 in. undersized and only refer todamper dimensions (sleeve thickness is not included). Electrical accessory wiring terminates at the accessory.Field wiring is required to individual components. Maximum velocity is based upon damper width. CONSTRUCTION FEATURES Blade Action:Opposed Frame Type:Channel Material:Galvanized Axle Material:Steel Axle Bearings:Synthetic Linkage Material:Steel Blade Seal:TPE Jamb Seal Mat.:304 SS Sizing:Nominal Frame Thickness (ga):16 Standoff Bracket:1.5 Actuator Type:24 VAC Actuator Mount:External Actuator Location:Left Side Fail Position:Closed Cycle:60 Cycle Jackshafting:No Preference Temp. Rating (F):180 NEMA Enclosure:Least Cost Actuator Sizing:Default SqFt ID #Tag Qty W (in.)H (in.)Drive Arr.Actuator Act.Qty. 2-1 2 18.000 8.000 Drive-CC-11-1FEL-0 TFB24 1 11/6/2014Printed Date: Stone Quarry 7-17-14Job: DampersMark: CAPS 4.15.1679 P:\CAPS Files\Stone Quarry 7-17-14.gfcj Page 5 of 6 Damper Drive Arrangements Job Summary -Start- Drive Arrangement: Drive-CC-11-1FEL-0 Damper Drive Arrangements Job Summary -End- 11/6/2014Printed Date: Stone Quarry 7-17-14Job: CAPS 4.15.1679 P:\CAPS Files\Stone Quarry 7-17-14.gfcj Page 6 of 6