Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Lecesse O and Ms - Division 22
Submittal Job: 14-0298 Stone Quarry Apartments 400 Spencer Road Ithaca, NY Spec Section Title: Plumbing Submittal Title: Hot Water Heaters SubcontractorKennedy Mechanical Primary Contact: Mark Jensen Phone Number: 585-232-2800 Supplier/Manufacturer: If this box is checked this submittal may differ from the plans and specs. Notes: This submittal contains both TH & Apt. bldg. hot water tanks. Please confirm alternate hot water tank for the TH's is acceptable. General Contractor: LECESSE Construction Services LLC Spec Section No: 220000-3 Submittal No: Revision No: RO Sent Date: 11/12/14 Required From Sub: 10/20/14 Approved By Architect: 75 Thruway Park Drive West Henrietta, NY 14586 Ph : 585-334-4490 Subcontractor Stamp LECESSE Stamp I HAVE PERSONALLY REVIEWED THIS SUBMITTAL AND IN MY ESTIMATION THIS DOCUMENT FULFILLS THE INTENT OF THE PLANS AND SPECIFICATIONS AND IS APPROVED FOR SUBMISSION. LECESSE CONSTRUCTION SERVICES LLC BY: Jason Socola Architect/Engineer Stamp Digitally signed by Scott Reynolds DN: nc =Scott Reynolds, o=lthaca Scott Reynolds Neighborhood Housing Serivces, Inc., ou, email=sreynolds@ithacanhs.org, c=US Date: 2014.11.21 12:13:29 -05'00' tate Water Heaters GS6-40-YB T SELECT POWER DIRECT VENT Residential Gas Water Heaters e'totilrftioreglit'arerili;;F ri :IN 3 tact iriT4oifOsPe tt-frie t'• 001QT .44,0024,rf,'9e4ters,\C7:,',' ',,,t1e\ittg#Itt7tt'ttt% RESODENTIAL Green Choice - m. Fr Power Direct Vent Design —Two -pipe closed-combusrion system draws all make-up air from outside the home, eliminating problems caused by insufficient indoor venrilarion. For installation versatility, system permits combined horizontal and vertical venring and air inrake runs up to 45 feet (including one 90" elblow using 3" Schedule 40 PVC, CPVC or ABS pipe. *Intelli-Vent" Gas Control — Equipped with nealry-indescructiblesilcon nitride hor surface igniter, and advanced electronics for more precise control of water temperature and easy to understand sysrem diagnostics. Quiet Modular Blower — Equipped with 110/120 volr electrical syrem (rating 3 amps or less), 7 -foot cord, standard 3 -prong male conneccor, PEXAN' Diffuser Dip Tube — Helps reduce lime and sediment buildup, maximizes hot water ourput. — PEXAN cross-linked polymer withstands long-term exposure to remperacures up ro 400"F, Green Choice''' Burner — Parented design reduces NOx emissions up ro 33% and complies with Southern California and Texas requirements. Durable Brass Tamper -Resistant Drain Valve. Glasslined Tank — For long-lasting protection against rust and corrosion, Aluminum Anode Rod — For additional protection againsr rust and corrosion. Factory -Installed Temperature & Pressure (T&P) Relief Valve. Thick, CFC -Free Foam Insulation. Ttr, 6 -Year Tank and Parts Warranty. Code Compliance —All models meet federal minimum energy standards effective January 20. 2004, according to latest editions of the National Appliance Energy Conservation Act (NAECA). They also comply with the latest editions of the B.O.CA National Codes, C.E.C., U.B.C., S.B.C.C., C.A.B.O. and the H.U.D. standards. All models design-certilied by CSA International according to ANS Z21.10.1 standards governing storage -type water heaters. VI/ I 11 11 I lib State Water Heaters GS6-40-YBPDT „no, REsorsIENTIAL SELECT POWER DIRECT VENT Residential Gas Water Heaters MODEL NUMBER G56 40 YBPLIT PEAK DEMAND OUTPUT ENERGY Mt Hour FACTOR Rating Gallons) 70 GS6 50 MDT 87 GS6 50 YRPDT 5 105 GS6 75 YRPDT 130 60 .59 .58 .58 GAL CAP. 40 50 50 75 BTU INPUT RECOVERY PER HOUR 90°F RISE HATURALt oiatoms t 40,000 40,000 65,000 70,000 41 41 64 72 VALUE" 16 16 16 16 Green Choice - 1,1= ,,n0,tira 1 n -I kav DIMENSIONS IN INCHES DRAFT A 8 1 C , D E 6' I 2.t.0_9p._ I i UUILLI 57 48-1/2 1 21 15 8 42 ' 3 66 57-1/2 1 21 15 8 51 , 3 69-1/2 61 21 15 8 ' 54-1/2''. 3 71-1/2 61-1/2 1. 26-1/4 1*. 15-1/2 8 , 54-3/4 3 For model number G56 50 YAP& 5,5 of 3" ABS vent pipe Is supplied and must Ise used for the first 5' al the elhaust outlet vent system. Far model number 656 75 YRPOT, 5° 011" CPVC vent pipe Is supplied and must be used for the lint 5' of the exhaust outlet vent system, Recoveries are rounded to nearest gallon Water Connections -3/4'. on all models When ordering Propane, flange "010 "II" 0 model number 16S6 40 HOPOT) 1- Propane Gas Inpulslitecoveries - 056 40 HOU: 36,000 BTU / 37 GM 058 50 HORT: 30.300 BTU / 39098 85650 HRPOT 5 60,000 BTU / 59 GPH 050 15 SWOT: 65,000 BTU / 67 GPH •R Value shown is "Performance Prated" IMPORTANT: VENTING AND COMBUSTION AIR REQUIREMENTS Read and follow requirements shown in the Installation Manual for Select Power Direct -Vent Gas water heaters dealing with type, placement and length of vent pipe and vent termination, as well as clearances required to provide adequate combustion air and proper ventilation. IMPORTANT: SEE INSTALLATION MANUAL FOR COMBUSTION AIR AND VENTING SYSTEM REQUIREMENTS FOR POWER DIRECT -VENT WATER HEATERS OPTIONAL 3' PVC HORIZONTAL VENT KIT KI Number 90064750051 INSTALL IN ACCORDANCE WITH LOCAL CODES s CIA/C:4P '22.! 6616,116-,? APPROX, SHIPPING WEIGHT 224 232 232 300 11.5°' MINT 3' VENT FROM TOP OF ° A A HEATER TO CENTER LINE OF FLUE LJ 0 I 1/2" GAS CONNECTION — a i V 1,2" C.AMETEP 211 0' 3 00.ETER PVC PiTAKE,CCPWSTUIP 201) OPTIONAL CONCENTRIC VENT KIT For complete information on limited warranties, consult written warranty, or contact the State Customer Care Center:I-BOO-365-0024. Slate Industries, Inc. reserves the right to make product charges or improvements 606 0)0) 9101 00)626, For fiteie infor-mation on the Select Power Direct Vent contact: State Watertleater 00 fl)1SS00 WaltiParkway Asttland CILY IN 31015 36570024:Toll-free USA - ° tateWitertleaterireorti S )4J// 52,. = ' ; re.Irer 0 High I.:Mimes, iliathirs, Nigel, end gaol Hewn die" ARPAOR WALL MOUNT CONDENSING WATER IRATE L)HW IKU Lochinvar WAN1 25 -PM ARMOR Wall Mount Condensing Water Heater Submittal Sheet WAN -Sub -Ola JOB NAME LOCATION ENGINEER WHOLESALER _ MECH. CONTRACTOR MODEL NO. TYPE GAS Btu/hr INPUT RECOVERY RATE IN GPH NOTES °F RISE STANDARD FEATURES .07 >AHRI Certified 96% Thermal Efficiency Walt Mounted Models > Modulating Burner with Srl Tumdown Direct -Spark Ignition > Low NOx Operation > Sealed Combustion ) Low Gas Pressure Operation Vertical & Horizontal Direct -Vent > PVC, CPVC, Polypropylene or SS up lo 100 Feet PVC/CPVC Sidewall Vent Termination Staintess Steel Heat Exchanger > All Welded Construction, Gasketless Design > 160 psi Working Pressure > Natural to LP. Conversion Kil > All Bronze Circulating Pump Row Switch > Temperature & Pressure Relief Valve > Tank Sensor / Adjustable High Limit w/ Manual Reset > Automatic Reset High Limit / Condensate Trap > Zero Clearances to Combustible Material / 5 Year Limited Warranty (See Warranty for Details) / 1 Year Parts Warranty (See Warranty for Details) SMART SYSTEMTM FEATURES > SMART SYSTEM Digital Operating Control > Multi Color Graphic LCD Display > Built In Cascading Sequencer For up to 8 Water Heaters > Multiple Size Water Heater Cascade Lead Lag Efficiency Optimization ) Building Management System Integration Modbus Communication (Optional) i0 -ID VDC Input to Control Modulation or Set point / 0-10 VDC Modulation Rate Output r0 -l0 VDC Input to Enable/Disable call for heat > Access to BMS Settings Through Graphic LCD Display > Low Water Flow Safety Control & Indication > Inlet & Outlet Temperature Sensors & Readout > Flue Temperature Sensor > Water Heater Pump Control > Pump Delay with Freeze Protection > Pump Exercise / Night Setback > Building Recirculation Loop Pump Control* > Time Clock > Maintenance Reminder ) Ability to program installer name and number into the product as service contact ) High Voltage Terminal Strip > 120 VAC / 60 Hertz /1 Phase Power Supply > Pump Control Contacts > Water Heater Pump Control Contacts /Building Recirculation Pump Control Contacts Low Voltage Terminal Strip ) 24 VAC Louver Relay Louver Proving Switch Contacts / Flow Switch Contacts > Alarm on Any Failure Contacts > Runtime Contacts > Tank Sensor Contacts > Cascade Contacts /0-10 VDC BMS External Control Contact > 0-10 VDC Bolter Rate Output Contacts 'Exclusive to Lochinvar OPTIONAL EQUIPMENT O Alarm Bell El Condensate Neutralization Kit LI Concentric Vent Kit (3' PVC/CPVC only) 0 ModBus Communications DBMS Gateway to LON or BacNet OSMART SYSTEM PC Software ARMOR WALL MOUNT Condensing Water Hel r Dimensions & Specifications UI-IVV rr\u Lochinvar WAN1 25 -PM H FLUE ELECTRICAL CONNECTIONS RELIEF VALVE ----la-11r TOP AIR INTAKE CONDENSATE TRAP SIDE G 14 BOTTOM CONDENSATE LINE Model Number 8t u/hr 'GPH @ puk 100° Rise Gas Water ` Air Vent Shipping Conn. Conn. Inlet Size W . (lbs) WAN125PM 125000 144 29-1/4" 18" 13" 1" 13" 3-1/2" 2.3/4" 5.1/1" 1/2" 9,_.,... S 1/2 13' 1/2" 1-1/4" WAN200PM 199,999 233 24-1 4" 25'° 20" 14" 11-3 4 31/2 1 1/2 lachlnvar. ILC 300 64addnc Simpson Parkway Lebanon. rennessae 37090 A. 615439.0900 (F: 615.447.1000 www i6Ciinv®t.fom 145 117 (Web Update 111 3—Paint,77SA. WHAT IS TI -IE DURATION OF THE IMPLIED WARRANTY? High Efficiency Wale LIMITED CONDENSING WATER HEATER Ax 1\ 1 I WHAT DOES THIS LIMITED WARRANTY COVER? This limited warranty covers Heat Exchangers for leakage, thermal shock or other malfunction caused by defects in materials and/or workmanship. It extends to the first owner as long as the water heater remains installed at its original place of installation. FIVE YEARS OF COVERAGE This limited warranty is effective 60 days from the date of manufacture as determined by the serial number. Model number and serial number are found on the rating plate affixed to the water heater. Heat exchangers are warranted against leakage and thermal shock for 5 years. Parts are warranted for 1 year. Any replacement heat exchanger or part under this warranty shall remain in warranty only for the unexpired portion of the original warranty. WHAT DOES THIS LIMITED WARRANTY NOT COVER? 1. This limited warranty does not cover leakage or other malfunction caused by: a. Defective installation and specifically, any installation which is made: I) in violation of applicable state or local plumbing, housing or building codes, or II) without a certified American Gas Association, ASME, or comparable Temperature Pressure Relief Valve, or III) contrary to the written instructions furnished with the unit. b. Adverse local conditions and specifically, sediment or lime precipitate in the tubes and/or headers or corrosive elements in the atmosphere. c. Misuse and specifically, operation and maintenance contrary to the written instruction furnished with the unit, disconnection, alteration or addition of non -approved components or apparatus, operation with fuels or at settings other than those set forth on the rating plate, or accidental or other exterior damage. 2. This warranty also does not cover: a. Production of noise, odors, discoloration or rusty water. b. Damage to surrounding area or property caused by leakage or malfunction. c. All labor costs associated with the replacement and/or repair of the unit, including: I) examination and replacement of parts claimed to be defective II) any freight, shipping or delivery charges; III) any removal, installation or reinstallation charges; IV) any material and/or permits required for installation, reinstallation or repair; V) charges to return the water heater and/or components to the manufacturer. d. Any failed component of the water heater system not manufactured as part of the water heater. e. Any water heater altered without prior written approval from Lochinvar, LLC. f. Any damage or failure due to contaminated air, including, but not limited to, sheetrock particles, plasterboard particles, lint, dirt or dust, entering the water heater or any of its components. g. Any damage or failure due to chemically contaminated combustion air, including, but not limited to, chlorine gas, halogenated hydrocarbons, Freon, entering the water heater or any of its components. ANY IMPLIED WARRANTY, INCLUDING THE WARRANTY OF MERCHANTABILITY IMPOSED ON THE SALE OF THE WATER HEATER UNDER THE LAWS OF THE STATE OF SALE ARE LIMITED IN DURATION TO ONE YEAR FROM DATE OF ORIGINAL INSTALLATION. HOW DOES STATE LAW RELATE TO THE WARRANTY'S Some states do not allow: 1. Limitations on how long an implied warranty lasts. 2. Limitations on incidental or consequential damages. The above limitations may or may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which may vary from state to state. WHAT WILL WE DO TO CORRECT PROBLEMS? If a defect occurs within the warranty period we will. 1. Provide a comparable replacement manufacture, or at our option, repair any unit which develops a leak in the heat exchanger within the warranty period. 2. Provide a replacement part, or at our option, repair any part which fails to function within the parts warranty period. To obtain a replacement, you must return the defective part to our distribution center. We reserve the right to verify any claims of defect by inspection. CONDITIONS We will not: 1. Repair or replace any water heater, or part, subject to conditions outlined in "What Does This Limited Warranty Not Cover?" 2. Reimburse any costs associated with repair and/or replacement. 3. Replace and/or repair any water heater without complete model number/serial number. 4. Replace any water heater without prior receipt of actual rating plate from the appliance. HOW TO KEEP THIS WARRANTY IN EFFECT To facilitate warranty service, you should: 1. Follow all instructions enclosed with the product. 2. Ensure that all installation and service is performed by a qualified service technician. 3. Retain all bills of sale or receipts for proof of installation, etc. 4. Contact your installer or dealer as soon as any problem or defect is noticed. 5. When necessary, allow our representative to inspect the unit. 6. For your reference, fill in the Model and Serial Number found on the unit's Rating Plate: Model Number Serial Number Date of Installation HIgh Eff olcory olrr Hrrrrrs, aollrrs and Pool Hc.lers Lochinvar, LLC, • 300 Maddox Simpson Pkwy • Lebanon, TN 37090 • 615-889-8900 / Fax: 615-547-1000 www.Lochinvar.com WAR7009 - Rev A 0 -2/12 -Printed in U. S,.A Erncienr) N'eler healers, Roller, and Ponl healers ARMOR WALL MOUNT° PRODUCT SUMMARY (WAN] 125,000-199,999 BTU/HR WATER WAN -125+ WAN -200 GALLON CAPACITY 1'0 1.8 HEATING SURFACE (50. FT.) 9.1 21.8 WATER CONNECTIONS 1-1/4" DRAIN 3/4,, 3/4" WATER FLOW RATE (GPM) HEAD LOSS (FT. OF HD.) MAX. WORKING PRESSURE (PSI) MAXIMUM WATER HARDNESS (GRAINS) 25, 25 GPH 70°F RISE 206 329 GPH @ 100°F RISE 144 233 GPH 03140°F RISE 103 165 # OF RELIEF VALVES T RELIEF VALVE SIZE 3/4" 3/4" RELIEF VALVE RATING (MBH) 1,912,000 1,912,000 RELIEF VALVE PRESSURE RATING (PSI) 150 150 GAS INLET CONNECTION 1/2" MAX. INLET PRESSURE, NAT 14" w.c. MIN. INLET PRESSURE, NAT 4.0" w.c. MAX. INLET PRESSURE, LP 14" w.c. MIN. INLET PRESSURE, LP 8.0" w.c. BTU/HR INPUT 125,000 1/2" 14" w.c. 4.0"'w,c'. 14" w.c. 8.0" w.c. 199,999 ELECTRICAL VOLTAGE/HEATER 120 VOLTAGE/CONTROL 24 TOTAL AMPS 3.0 120 24 3.2 #0F ELECTRICAL CONNECTIONS DIMENSIONS HEIGHT WIDTH 29-1/4" 18-1/2" DEPTH 18 29-1/4" 18-1/2" 25" SERVICE CLEARANCES (RECOMMENDED) FRONT 24' 24" RIGHT SIDE 0" 0 LEFT SIDE 0" TOP DIRECT VENTING SIZE 3 VENT CATEGORY IV IV VENT MATERIAL PVC PVC Lochinvar, LLC • 300 Maddox Simpson Pkwy • Lebanon, TN 37090 • 615-889-8900 / Fax: 615-547-1000 ,Lo hint/ ' Gom WAN -PS -02 (Replaces WAN -PS -01) 08/13 Printed in U.S.A. CONDENSING COMMERCIAL GAS WATER HEATERS SMART OPERATING CONTROL FEATURING A BUILT -1N CASCADING SEQUENCER. 2 WALL MOUNT SPACE SAVING MODELS - 125,000 BTU/HR AND 199,999 BTU/HR FIRING RATE NMODULATTON TO 5:1 DIRECT -VENT FLEXIBILITY TO 100 FEET A°WAIL MOUNTED WATER THEATER Lochinvar has added to its successful stabil ss steel, condensing; Armor water heater series with wall mounted. models.The Armor Wall Mount is available in two sizes,125,000 and 199,999 Btu/hr input. The light weight but powerful water heaters hang t any wall to giveyou more free space in your mechanical r000m, THE 'BETTER IDEA" SYSTEM AND INSTANTANEOUS WATER HEATER The water heater and tank combination is the heart of Lochinvar"s "BETTER IDEA" water heating philosophy. The ARMOR water heater is always installed with a separate storage tank to provide an effective water heating package for commercial domestic water systems. The industry has made a few unsuccessful attempts at applying residential instantaneous water heating to commercial applications. Instantaneous products are outmatched by the faster, larger and variable hot water demands of a commercial application. Storage is essential to supply the water to a system at a variety of speeds and volumes. What's more, the ARMOR "BETTER IDEA" system delivers tower equipment costs and lower installation costs than a comparable instantaneous package. FULLY MODULATING WITH 5:1 TURNDOWN ARMOR features advanced Negative Regulation (Neg/Reg) sealed combustion technology, permitting fan speed to constantly adjust the volume of fuel and air entering the burner. This ensures that ARMOR can safely and reliably operate with supply gas pressure as low as 4 inches water column. ARMOR is equipped with fully modulating combustion with 5:1 turndown. This means ARMOR can fire as low as 20% of maximum input when water heating demand is lowest, and increase the firing rate up to 100% as demand increases. The result is better overall efficiency and less cycling, compared to all other tank -type units which are "on-off," which means they can only fire at 100% of maximum input. STAINLESS STEEL CONDENSING HEAT EXCHANGER The stainless steel design provides superior resistance to corrosion caused by condensation from low entering water temperatures. Traditional commercial water heaters will fail early with low entering water temperatures; however, with the ARMOR the lower the supply water temperature the more efficiently it performs throughout the life of the heater. A STAINLESS STEEL STORAGE TANK Available in 60, 80 and 119 gallon capacities, Lochinvar's Lock -Temp Stainless Steel storage tank makes a perfect companion to the Armor Floor Mount and Wall Mount water heaters. 14 gauge 316L stainless is formed, cut and fully welded into a light weight tank. The stainless steel is "passivated" with a nitric acid treatment to re-establish the oxide level of the metal after welding and to ensure corrosion resistance. The tank is finished with a dent resistant polypropylene jacket and high density expanded foam insulation rated to exceed ASHRAE Energy Efficiency Standards for standby losses. Lochinvar backs its Stainless Steel Storage Tank with a 10 year limited warranty. SMART THE,. ULTIMATE WATER HEATER OPERATING CONTROL WITH GRAPHIC LCD DISPLAY �UATERHEATERS WITH DIFFERENT INPUTS CAN, BE CASCADED TOGETHER TO MAXIMIZE TURNDOWN CAPABILITY COMPATIBILITY WITH COPPER -FIN irNON-CONDENSING ,, W�tAMR HEATER TO CREATE A FRONT END LOADING SYS' NIGHT SETBACK CAPABILMTIES SETBACK OF STORAGE TANK TEMPERATURE NATER HEATER PUMP CONTROL PUMP DELAY WITH FREEZE PROTECTION BUILDING RECIRCULATION" PUMP CONTROL* PUMP EXERCISE FhiGH-VOLTAGE TERMINAL STRIP 110 VAC INPUT TO WATER HEATER > DRY CONTACTS FOR WATER HEATER PUMP CONTROL > DRY CONTACTS FOR BUILDING RECIRC. PUMP CONTROL. LOW -VOLTAGE TERMINAL .STRIP rli wl " USB CONNECTION POINT FOR OPTIONAL wrTH 28 POINTS OF CONNECTION` > SMART SYSTEM PC sOFTWAREWITH > 0.10 VDC WATER NEATER RATE OUTPUT ADVANCED SEIUP /5,ND DIAGNOSTICS > 0.10 VDC HEAT DEMAND INPUT > MODBUS CONTACTS MODBUS COMPATIBIUTY (OPTIONAL) LONG-LASTING "LIFE CYCLE" EFFICIENCY In a standard tank -type water heater, lime scale builds up over time on important heattransfer surfaces, insulating the water from the heat source. This buildup in the bottom of the tank and around the flue tubescan cause tank•type heaters to fail in as tittle as 2.3 years. This decreases thermal" efficiency and increases operating cost. Just 1/4" of lime scale in the tank can increase operating costs as much as 25%! ARMOR's "Better Idea" concept eliminates the impact of lim°e scale, maintaining a high rated thermal efficiency and low operating cost throughout its long life cycle. The chart below illustrates how ARMOR is a better way, delivering true "life cycle efficiency" compared Traditional tank -type water heater flue tubes with nearly 6" of lime scale buildup EFFICIENCY L055 DUE TO LIME SCALE BUILDUP % EFFICIENCY OVER HEATER Lin ARMOR icor- 90 STANDARD 601. TANK -TYPES 76% d6 . 50% 40% 30%, 20% 10% 0%'0 R 3 4 5 YEARS OF OPERATION NOTE The chart is based on timescale build-up 091/16 inch per year which reduces operaling efficiency approximately 8-10% per year LEXI B LE VENTING OPTIONS - Up to 100 feet of air intake and 100 feet of exhaust vent with PVC, CPVC, Polypropylene or SS. ARMOR offers 5 venting options and tremendous flexibility for placement of units within the building, because it permits direct -vent air intake and exhaust runs up to 100 equivalent feet using either PVC, CPVC, Polypropylene or AL29-4C stainless steel vent pipe. Intake and exhaust runs can terminate horizontally through a sidewall or vertically through the roof. Direct Vent Sidewall Direct Vent Vertical Vertical w/5idewall Air Concentric Direct Vent Concentric Direct Vent Vertical Sidewall ARMOR"' WALL MOUNT WATER HEATER DIMENSIONS AND SPECIFICATIONS 7-1/2" ELECTRICAL CONNECTIONS RELIEF VALVE AIR INTAKE CONDENSATE TRAP 18-1/2" 2-314" SIDE -1/2" CONDENSATE LINE BOTTOM Wall Mount Armor Water Heater, Natural Gas, WA 11 125 PM 125,000 Btu/nr Input, Pump Mount Model Number Guide Model Btu/hr GPH @ Number Input 100° Rise Gas Water Air Vent Shipping Conn, Conn. Inlet Size Wt. (lbs.) WAN125PM 125,000 144 29-1/4" 18" 13" 1" 13" 3-1/2" 2-3/4" 5-1/2" 6' 1/2" 1" 3" WAN200PM 199,999 233 29-1/4" 25" 20" 14" 11-3/4" 3-1/2" 1-1/2" 5-1/2" 13" 1/2" 1-1/4" 3" STANDARD FEATURES > AHRI Certified 96% Thermal Efficiency > Wall Mounted Models > Modulating Burner with 5:1 Turndown > Direct -Spark Ignition > Low NOx Operation > Sealed Combustion > Low Gas Pressure Operation > Vertical & Horizontal Direct -Vent > PVC/CPVC, Polypropylene or SS up to 100 Feet > PVC/CPVC, Polypropylene Sidewall Vent Termination ) Stainless Steel Heat Exchanger > AIL Welded Construction, Gasketless Design > 160 psi Working Pressure > Natural to L.P. Conversion Kit > All Bronze Circulating Pump > Flow Switch > Temperature & Pressure Relief Valve > Tank Sensor > Adjustable High Limit w/ Manual Reset > Automatic Reset High Limit Condensate Trap > Zero Clearances to Combustible Material > 5 Year Limited Warranty (See Warranty for Details) > 1 Year Parts Warranty (See Warranty for Details) SMART SYSTEM' FEATURES r SMART SYSTEM' Digital Operating Control > Multi Color Graphic LCD Display > Built in Cascading Sequencer for up to 8 Water Heaters > Multiple Size Water Heater Cascade > Lead Lag > Efficiency Optimization > Building Management System Integration > Modbus Communication (Optional) > 0-10 VDC Input to Control Modulation or Set point > 0-10 VDC Modulation Rate Output > 0-10 VDC Input to Enable/Disable call for heat > Access to BMS Settings Through Graphic LCD Display > Low Water Flow Safety Control & Indication > Inlet & Outlet Temperature Sensors & Readout > Flue Temperature Sensor > Water Heater Pump Control > Pump Delay with Freeze Protection > Pump Exercise > Night Setback > Building Recirculation Loop Pump Control > Time Clock > Maintenance Reminder > Ability to program installer name and number into the product as service contact 3" 145 3" 177 > High Voltage Terminal Strip > 120 VAC / 60 Hertz / 1 Phase Power Supply > Pump Control Contacts > Water Heater Pump Control Contacts > Building Recirculation Pump Control Contacts > Low Voltage Terminal Strip > 24 VAC Louver Relay > Louver Proving Switch Contacts > Flow Switch Contacts > Alarm on Any Failure Contacts > Runtime Contacts > Tank Sensor Contacts > Cascade Contacts > 0-10 VDC BMS External Control Contacts > 0-10 VDC Boiler Rate Output Contacts FIRING CONTROL SYSTEMS > M9 Standard Construction OPTIONAL EQUIPMENT > Alarm Bell > Condensate Neutralization Kit > Concentric Vent Kit (3" PVC/CPVC only) > ModBus Communications > BMS Gateway to LON or BacNet > SMART SYSTEM PC Software Lochinvar, LLC t 47' 300 Maddox Simpson Parkway „ 't ..., . Lebanon, Tennessee 37090 r. P615 889 890 / F. 615 547 100 t ii iiiiel.,.41-el:l.smito9,1i+reier,f,ret..;"t 7,7,01 IIN.Titra,tWi . P '''''''',' 1,-40,,,wry Cot , WAN -01 (Reprinted 4/13 50/ P00101.0f. Lochinvar RJS080M -4 -Loc High ErncleeryWatur Healers, aml Pool 'realm JOB NAME LOCATION LOCK -TE ROUND JACKETED TANK Submittal Sheet TRJ-Sub-08f 1' Lt K TEMP ROUND JACKETED STORAGE TAN ENGINEER WHOLESALER MECH. CONTRACTOR MODEL NO. RJS080M IS REQUIRED GALLON CAPACITY TANK CONSTRUCTION WORKING PRESSURE DIMENSIONS LINING NOTES Standard Features • Five -Year Limited Warranty (See warranty for details) • Lock -Temp Baffle • Magnesium Anode • ASME Certified, "1-11_,W" Stamped • 125 Working Pressure (Except R1 series) Optional Tank Linings El Glass Lined D Cement Lined Optional Equipment Place an X in the box by all options that apply 0150 psi Working Pressure El Temperature and Pressure Gauge Handhole (4"x 6") ASME Tanks Only tilling Lugs El Manway 0125 psi Temperature and Pressure Relief Valve 0150 psi Temperature and Pressure Relief Valve Li0-1w Frai Lochinvar RJSOBOM Lock -Temp® Round Jacketed Storage Tanks Dimensions & Specifications Vertical Round Jacketed Glass Lined Tanks NPT rTP OWL T CET. NECTDON tArT- r Model Gizl. Shipping Weight Number Cup. A B D E 125 psi 150 psi RJS080M 80 63" 25-1/4" 9-1/4'' 14-1/4" R1S085M 85 49-1/2" 28" 9-1/2" 14-1/2" 1115120M 119 62" 29-1/2" 9-1/2" 14-1/2" RJA120 119 62-1/2" 28" 9-1/2" 14-1/2" RJA175 175 66-1/4" 32" 11-1/4" 17-1/4" RJA200 200 77-1/4" 32" 11-1/4" 17-1/4" Glass Lined only " A = ASME Construclian 240 255 352 365 578 634 A TAMSTAT j 50 Tr T0.3500 120 GALLON 3.41° Far Vertical Round Jacketed ASME Tanks Model Gal. Shipping Weight Number. Cap. A B D E 125 psi 150 psi VA0257 257 91" R10318 318 80" rA0432 432 80" R10504 504 92" R10650 650 92" R10752 752 104" R'A0940 940 128" 34" 18" 26" 904 40" 19-1/2" 27-1/2" 987 46" 21" 29" 1,188 46" 21" 29" 1,329 52" 23-1/2" 31-1/2" 1,817 52" 23-1/2" 31-1/2" 2,030 52" 23-1/2" 31-1/2" 2,710 904 981 1,188 1,329 1,817 2,030 2,710 • Indicates lank lining, flvlanivav is optional on 257 and 31B only Manu, is standard on 432 and larger. G=Glass Lined C=Cetnent lined OuTLEr 1,444° TAP CONTEttlon roan..otii caw ofitramovs. Horizontal Round Jacketed ASME Tanks Model GallonShi. pping Weight Number Cu atil A B Diameter 125 .si 150 ,si 11•40250H 250 41" 87" 34" 1,157 1,157 frA0300H 300 47" 76" 40" 1,355 1,355 R*A0400H 400 53" 16" 46" 1,587 1,701 R*A0500H 500 53" 88" 46" 1,711 1,853 R106000 600 59" 88" 52" 2,053 2,053 11*A0100H 700 59" 100" 52" 2,399 2,399 11`41000H 1000 59" 124' 52" 3,114 3,114 *Indicates Tank Linings G =G lass I ined C=Cement I ined -`t441k. c 1-1M' T8P 2' NPT L5ithZ0 CONNECTION .urtEr was ce—AGUASTAT ,NPT • MANWA51501110NAL ON 25011 AND MN ONLY. MANWA8 IS STANDARD 08 40011 AND LARGER. Lochinvar, LLC • 300 Maddox Simpson Pkwy • Lebanon, TN 37090 • 615-889-8900 / Fax 615-547-1000 www.Lochnvar.com 13A8IVVAYT WINN 0Web Upda le 71131 7502—Primed in U.S.A. 170 ifW 1-pw The new degree of comfort Professional Prestige High Efficiency Condensing onden^ng ower Direct Vent gas water heaters are a perfect choice when indoor air quality is a concern Efficiency • 0.82 EF • ENERGY STAR rated Performance • FHR: Up to 93-gaflons for natural and LP gas • Recovery: 43.6 to 48.5 at a 90 degree rise, based on model Self -Diagnostic System • ntegrated system control for easy instaflation and service • Diagnostic system control can be replaced without draining the water heater Low Emissions o Eco -friendly burner, low NOxdesign Features o Power direct vents are an ideal choice when either indoor air quality or negative air pressure are concerns • Two -pipe system: one pipe pulls in outside air for combustion and the other exhausts combustion gases o 120VAC, 6OHz.induced draft blower • New whisper quiot blower Innovative Technology • Proven centor flue design with submerged coil type condensing heat exchanger • Heat exchanger is porcelain coated inside and out for increased product life Flammable Vapor Detection System • FVIR compliant protective • Control system that disabies the heater in the presonce of flammable vapor accumulation Flexible Venting Options • Long venting engths up to 60 feet • Use 2 or 3 inch diameter PVC, ABS, or CPVC vent pipe options. (In Canada ULC S636 PVC and CPVC must be used.) • Vertical or horizontal termination • Concentric vent kit available Longer Life • Duaanode rods protecthe tank from corrosion High Altitude Compliant • Models are certified for appVcations up to 9,000 feet above sea level Plus... • Enhanced flow brass dram vaive • Temperature and pressure relief valve included ° Low lead compliant • Durable silicon nitride igniter (HSI) • Inlet tube with diffuser enhances heat transfer • Front access to condensate trap and vent pipe • Condensate neutralizer option • Standard replacement parts Warranty • 6 -Year Iimited tank and parts warranty* See Residential Warranty Certiticate tor complete information Units meet or exceed ANSI requirement and have been tested according to D.0.E. procedures. Units meet or exceed the energ efficiency requirements of NAEGA, ASHRAE standard 90, ICC Code and aII state energy efficiency performance criteria, Residential Gas Professional Prestige High Efficiency Condensing Power Direct Vent Water Heaters Professional Prestige Condensing High Efficiency ower Direct Vent rd48-Gallo0Capacities Up to 40,000 Btu/ Natural and LPGas See dimensions chart on back. PRINTED IN U S A 09/13 WP FORM NO RHE-101EF Rev. The new degree of comfort:" Water Residential Gas Professional Prestige High Efficiency Condensing Power Direct Vent Water Heaters Professional PrestigeTM High Efficiency Condensing Power Direct Vent Specifications DESCRIPTION FEATURES T GAS INPUT IN RECOVERY IN I FIRST HOUR HT. TO HT. TO Y TOP OF TOP OF THOUS. BTINH G.P.H. 90° RISE i DEL. G.P.H. P GAL MODEL ,--. — - --,.- --- .—., VENT AIR INLET E CAP. NUMBER NAT. LP NAT. LP NAT. 1 LP A B Short 38 RHE40S 40 49.5 7 r 74 80-3/8 60-1/8 Shod: 38 RHE40SP 36 436 : 74 60-3/8 60-1/8 48 RHE50 Tall „: 40 48 5 I: 93 1 68-3/4 68-5/8 1 Tal 1 48 RHE5OP 36 1 43.6 ir . 93 68-3/4 68-5/8 ROUGHING IN DIMENSIONS (SHOWN IN HT. TO WATER HI TO TANK ! GAS CONN, SIDE TAP HT, 1 DIAM, CONN. CNTR. VALVE C 0 6 F 51-1/16 :1 22-1/8 14-1/8 8 44-1/4 51-1/16 22-1/8 14-1/8 8 44-1/4 59-11/161 22-1/8 14-1/8 8 52-7/8 59-11/16 22-1/8 14-1/8 8 52-7/8 INCHES) ENERGY INFO. WATER FRONT ENERGY CONN. TO SHIP. FACTOR SIZE BACK WT. _ 11 I (LEIS) NA'. LP 3/4 26-11/16 220 0.82 3/4 26-11/16 r: 220 r 092 r 3/4 26-11/161 250 1 282 3/4 26-11/16 250 T a 82 Energy Factor based on D 0 E (Department ot Energy) lest procedures COMBUSTION AIR INLET COLD WATER gotart60000 COMBUSTION EXHAUST (9EN1) ABC Air -Inlet and Venting Information TOP FITTING SIPS' From Sea Level Through 5,999 ft. Above Sea Level Vent & Combustion Minimum Allowed Maximum Allowed Vent Air -Inlet Equivalent Vent & Combustion Equivalent Vent & Combustion and Combustion Pipe Diameter Air -Inlet Lengths - Air -Inlet Lengths - Air -inlet System Model (Inches) Each Pipe Run (Ft.) Each Pipe Run (Ft.) Termination(s) RHE4OS 2 7 30 90° Elbowsoncen lc 1 DtY * RHE4OS 1 3 7 60 90° Elbows Concentric* RHE50 2 7 30 90° Elbows RHE50 3 7 60 90° Elbows Concentric" From 6,101 ft. Above Sea Level Through 8,999 ft. Above Sea Level Vent & Combustion Minimum Allowed Maximum Allowed i Vent Air -Inlet Equivalent Vent & Combustion Equivalent Vent & Combustion , and Combustion Pipe Diameter Air -Inlet Lengths - Air -Inlet Lengths - Air -Inlet System finches) Each Pipe Run (Ft.) Each Pipe Run (Ft.),,Termination(s) RHE4OS 2 Not Allowed Not Allowed - - RHE4OS i 3 7 45 90° Elbows Concentric* RHE50 2 i Not Allowed Not Allowed RHE50 I 3 7 45 90° Elbows Concentric* Model One 90° elbow is equivalent to 5 feet of straight pipe. One 45° elbow is equivalent to 2 5 feet of straight pipe The vent and combustion air inlet terminations are not included in the equivalency calculations Use only Rheem 3 inch concentric termination kit SP20245 In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice. Rheem Water Heating • 101 Bell Road Montgomery, Alabama 36117-4305 • www.rheem.com _-0 PRINTED IN USA 09/13 WP FORM Na RHE-101EF Rev ' 11-111i0P "MI so ad CERTIFIED www ahridrrectoryArg This water heater qualifies for Federal Energy Efficiency Tax Credit when placed in service between February 17, 2009 and December 31, 2013. Certificate of Product Ratings AHRI Certified Reference Number: 5609871 a u acu SALES COMPANY, INC. Trade/Brand name: RHEEM • Rated as follows in accordance with Department of Energy (DOE) Water Heater test procedures as published in the latest edition of the Code of Federal Regulations, 10 CFR Part 430 and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Date: 7/16/2014 'Status: Active -FR 49 -if. Energy Factor: First Hour Rating: 0.82 74.0 Gallons per hour The following data is for reference only and is not certified by AHRI: Energy Source: Water Heater Type: Rated Storage Volume: Input: Recovery Efficiency: Heat Traps: Natural Gas Storage 38 Gals 40.0 MBtuh 90 % Yes FootNote 15 - Includes Pipe Insulation FootNote 32 - Temperature & pressure relief valve insulation * Ratings followed by an asterisk (*) indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahrldirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at www.ahridirectory.org, click on "Verify Certificate" link and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which is listed above, and the Certificate No., which is listed at bottom right. ©2014 Air -Conditioning, Heating, and Refrigeration Institute I CERTIFICATE NO.: AIR-CONDITIONING, HEATING, & REFRIGERATION INSTITUTE we make life bettei"' 130500052697811407 LECESSE CONSTRUCTION The Power of Partnership 75 Thruway Park Drive West Henrietta, NY 14586 Ph : 585-334-4490 Job: 14-0298 Stone Quarry Apartments 400 Spencer Road Ithaca, NY Spec Section Title: Plumbing Submittal Title: Tub & Showers PD/SD Subcontractor:Kennedy Mechanical Primary Contact: Mark Jensen Phone Number: 585-232-2800 Supplier/Manufacturer: Clarion If this box is checked this submittal may differ from the plans and specs. Notes: Please confirm location of shower head, slide rail, and diverter for ADA showers. * FOR OWNER REVIEW/APPROVAL PLEASE SIGN AND RETURN General Contractor: LECESSE Construction Services LLC Spec Section No: 220000-5 Submittal No: Revision No: RO Sent Date: 10/29/14 Required From Sub: 10/20/14 Approved By Architect: Subcontractor Stamp LECESSE Stamp I HAVE PERSONALLY REVIEWED THIS SUBMITTAL AND IN MY ESTIMATION THIS DOCUMENT FULFILLS THE INTENT OF THE PLANS AND SPECIFICATIONS AND IS APPROVED FOR SUBMISSION. LECESSE CONSTRUCTION SERVICES LLC BY: Jason Socola co Reynolds gra ysigne..y co eyno DN: cn=Scott Reynolds, o=lthaca Neighborhood Housing Serivces, Inc., ou, email=sreynolds@ithacanhs.org, c=US Date: 2014.1030 15:01:05 Clarion ADA -Compliant —ub / Siower w/ 18" A DOCDF(S- oron Wb Clarion Bathware MP7911L 11911Utioll I.129ronti E LEVATION liMOntrul [S13.7inint Ill3tlann I 1. • Drain tuSimmt pLAN 60" /52ifinut Jubqhcover Leji_f land liersiory7911L) Shown I25t ur [457mml 1394Unnt 11 11 SECTION "A -A" PRODUCT SPECIFICATIONS: * Product complies with NAHB, HUD UM -73A, and ANSI -Z 124.1.2. • Product has a Class 13 fire rating as determined by ASTM E-114 test method. " When properly oecessorired and installed, product meets mquirements of ADA (2010 Sid), ICC/ANSI A 117.1-2009, ABA or UFAS. Reinforced & slip resistant floor. • Integral I" I.25mm) nailing flange. ▪ Factory drilled 2 1/2" [64min] overflow, * Door Opening: W-56" [1422mm] H-57 1/2" 11461mm] • Bothwell Dimensions (At Top): W-52" [132Imml D-23" [584mm1 H-16 1/4" [417nuu] ▪ Bothwell Dimensions (Al Bottom): W-45 1/4" [I 149mrol 3-I9 1/2" [495mml * Bothwell Capacity (At Overflow): 52 Gal L1971.4 • %Voter Level (At Overflow): 12 7/4" [324mml • All dimensions +/- 1/4" [6.4mml • Clarion Bathwarc reserves the right to change design and/or dimensions. • Dimensions are the same for RE, MP.:and all other versions of this model. 7911L or 7911R 60" [1524mm] Tub/Shower w/ 18'' Apron & Left or Right Hand Drain 4 BAT FI WARE 44 Amsler Ave. Shippenville, PA 16254 Phone: (814) 226-5374 Toll Free: (800) 576-9228 Fax: (814) 226-0730 www.elarionbatlovareocom Signatures For Appro.)vul., Custorner: Areli./Ett gr: Dale: Dwg. 7911L or R -CUT Quote #: Job Name: Dwg, By: NM H DATE: 5/22/2014 *** IMPORTANT NOTICE Clarion Elathwore reserves the right to change the design and/or dimensions nf its products at an timc. This drawing may have been updated since this publication was Issued. Before placing an order for any product, refer to our website at vmw.clarlonbathware.com to obtain the most current drawings far 211V products that you wish to purchase. Compare the date of revision of the drawing that you have with the one on the drawing on our website. If you do not have Internet access. please call your sales representative or Clarion Bauhware's soles department at 1-800-576-922/1. books. 1-11:5 Clarion Bathware MP791 1 L Right Hand Version (MP7911R) Shown 64" MP79111, or MP79111t LA,skika hvi4 GeDE) 6 [1524min] Tub/Shower w/ 18" Apmn & Left or Righ an Drain RECOMMENDED ACCESSORIES 1. ustr-con-B-B-A-Rigry 3) 2..44 -501S -GRAB -BAR (Qty 2) REMONP ; --of-FGLDLHQ SEAT 60'SONE--DISH 5 riteimmvA-mixitqa VALVE 6.4114GB-24-HA 44E-LE1-SHWR 4/4-GURT ..ROD 8-GURTAi1iNat Shown) 4 BATHWARE 44 Amsler Ave. Shippenville, PA 16254 Phone: (814) 226-5374 Toll Free: (800) 576-9228 Fax: (814) 226-0730 1,VWW,Clarionbathware.com Signatures For Approval: Customer: Arch./Engr: Quote #: Job Name: Date: Dwa. rl MP791 I L or R -IS Dwg, By: 1\11V DATE:5/01/20 4 *** IMPORTANT NOTICE *** Clorion Bathware reserves the right to change the design and/or dimensions of its products at any time. This drawing may have been updated since this publication was issued. Before placing an order for any product, refer to our website at WWW.elarionbuthwure.com to obtain the most current drawings for any products that you wish to purchase. Compare the date of revision of the drawing that yuu hove with the one on the drawing on our website. If you do not have internet access, please call your sales representative or Clarion Rathware's sales department at 1-000-576-9228. SHOWER & TUB/SHOWER INSTALLATION Rev. #: 2/24/2014 Suggested Tools China- Big incncomionni Flit Mildew litinincipt rnin lononig raiiIsmil Sono Please consult all Tocaland state building codeand read the entire installation instructions prior to beginning the installation of this unit to ensure that the installation is performed correctly. Clarion Bathware's tub/showers are to be stored in a dry area prior to installation to prevel1t moisture from attacking the reinforcement material which could cause warpage to the unit. %YARNIMG: FAILURE TO FOLLOW THESE INSTALLATION INSTRUCTIONS COULD VOID THIS PRODUCTS WARRANTY. A Iicensed plurnber is required to install or suponiurthe installation of these units. These units are thoroughly tested in the pEant to ensure Uheirubi|iLyLodmin*uterpmper|y. FaiTure to foIlow these handling and iiistallation instructions inav cause improper drainage, thus voiding the unit's warranty. Pocket dirnensions and dram location cari be obtained from vour retailer or at vx'n/.clarion6ath`vorozum/uumh (1) enter model nLlmber of the unit then cI ick search, (2) select the product picture. (3) select product cut sheet (pdf) at bottorn right orthe page. Clarion Bathware's products are designed to be self-supporting. However, in cases where the occupant ofthe liorne has excessive weight, we recommend that the unit be installed on a bedding material ofcement orcasting plaster. Use ofa beddirig material is required ifthe unit is being installed in a high use facility. (ie: dormitory, locker room, nursing home, motel, hotel, etc.) The use of a bedding material however is optional and done at the discretion of the ouxbomur. If a bedding material is used, be sure to place a moisture barrier, such as plastic, between the bedding cornpound and the unit Page /ofs I U13 TUB Clarion Bathware MP7911i Step #1 Figure 1 Framing the Pocket Frarne a square and plumb pocket0odimension oCthe unit. Ifthe unit being installed hasa whirlpool option installed, future access to the pump and parts should be considered when installing. It is advioed, and is required by many local and statbuilding codes that an access area be incorporated into the frarning for u*6ir|poo|od tub/shower Fig. 1 Square Piumg Framing Moor = H= Height of framing pocket should be at least the height of unit that is being installed. * W= Width of framing pocket should be no wider than the width of the unit being installed. Shims may be required. D= Dimensions provided on the cutsheet of the unit which show the dram location. NOTE: Accommodations should be made in the pocket dimensions for any accessories attached to the unit. Page 2 of 5 TUB Clarion Bathware MP791 1 L Step #2, Figure 2 Setting the Unit Plumbing fixture can be installed prior to setting the unit into the framing pocket or after. Install the drain and make sure that it is sealed properly and not leaking. Set the unit into the framed pocket. Check that the drain is not resting on anything which can force the unit floor upwards. Plumb and level the unit. The legs of the unit must contact the floor for proper support. Shims may be placed under the legs to maintain solid contact where needed. Use appropriate size shims to fill any gaps between the flange and the framing members. Once the unit is plumb and level and any gaps are shimmed, secure the vertical flanges every 6" or as necessary and the horizontal flanges wherever they come into contact tvith the studding with galvanized nails or screws. Pre -drilling for the fasteners may be desired to reduce the risk of damaging the unit. (In an application where the unit is installed over wall board and will be installing a Clarion Bathware Trim Kit, for best results your fasteners will need to be flush with the nailing flange. Clarion Bathware recommends centering and counter sinking a corrosion resistance fastener on the nailing flange. Raised fasteners will result in a problematic finishing process of the trim kit.) Fig. 2 IlatiegotaT Flanges Attach Vertical Flanges ery 6" to 8" or as necessary with galvanized nails or screws to insure complete contact with the studding. Horizontal Flanges must be secured anywheie that they come Into contact with studding, V e rut al ne5, ffwizontal flanges Final Notes: You can finish off your new unit with a variety of materials which are accepted by local building codes. Some ideas are tile, drywall caulking, drywall mud, plaster, wood or plastic trim. Clean your new tub with a liquid detergent and warm water. Do nOt Me any abrasive cleaners such as scourinnder or liquid abrasive cleaners. Page 3 of 5 TUB Clarion Bathware MP791 1 L IF A BEDDING MATERIAL IS USED UNDER A UNIT; CEMENT SLURRY, THIN MORTAR MIX, PLASTER OF PARIS, OR A CONIPARABLE FLOOR FILLING COMPOUND THAT IS NOT WATER SOLUBLE ARE PROPER BEDDING COMPOUNDS. WATER SOLUBLE MATERIALS, FOAM AND OTHER EXPANDING MATERIALS ARE NEVER TO BE USED AS A BEDDING COMPOUND. NOTE: ANY BATHING WELL CAN BE 1VHIRLPOOLED. IT [S IMPORTANT TO DETERMINE WHERE YOU WILL HAVE ACCESS TO THE PUMP IF IT NEEDS SERVICED IN THE FUTURE. ACCESS TO THE WHIRLPOOL PUMP AND PARTS SHOULD BE CONSIDERED PRIOR TO PURCHASING AND/OR INSTALLING A WHIRLPOOLED UNIT. AN ACCESS AREA ON WHIRLPOOLS IS REQUIRED BY MANY BUILDING CODES. ALL WHIRLPOOLS MUST BE WATER TESTED PRIOR TO BEING INSTALLED. FAILURE TO WATER TEST CAN VOID TILE WARRANTY. IF YOU HAVE ANY QUESTIONS REGARDING INSTALLATION OF YOUR CLARION BATHWARE PRODUCT, PLEASE CALL OIJR CUSTOMER SERVICE DEPARTMENT AT 1 (800) 576-9228 EXT. #818 OR BY E-NIAIL AT CUSTOMERSERVICE@CLARIONBATHWARE.COM JOB SITE INSTALLATION OF OWNER SUPPLIED ACCESSORIES All Clarion Bathware units purchased with supplied grab bars arc custom reinforced at the factory to accommodate the mounting of said bars. Any grab bars installed on a Clarion Bathware unit at the job site must have proper reinforcement (wood support and backing plates) at all mounting areas and should comply with ANSI A117.1, Uniform Federal Accessibility Standards (UFAS) and ASTM F446 specifications for grab bars in the bathing area. Job -site installation of third party supplied grab bars is entirely at the risk and full responsibility of the owner. Any damage to Clarion Bathware units or the property during or after grab bar installation. or any injuries due to improper installation remain the sole responsibility of said owner and cannot be attributed to Clarion Bathware, Inc. ***WE suoGasi THAT THE CUSTOMER AVOIDS I,is[No, A BATH MAT IN THE mit AS 11 COULD CAUSE WATER STAINS OR BLISTERING TO THE FENTSH SURFACE OF THE UNIT, CLARION BATHWARE PRODUCTS ARE CERTIFIED TO MEET NAI -IB STANDARDS, HUD/FI-IA, BOCA, 1 -{UD UM -73A, ANSI Z124.1 AND ANSI Z124.2. FOR DETAILS, REQUEST NAHB RESEARCH CENTER CONFIRMATION. I 44 Amsler Avenue Shippenville, PA 16254 (814) 226-5374 (800) 576-9228 Customer Service: Ext. #818 Fax: (814) 226-0730 Ivww.clarionhathware.coni kc Page 4 of 5 TUB Clarion Bathware MP7911L CL ' ON BATHWARE 44 Amsler Avenue Shippenville, PA 16254 Phone (800) 576-9228 Fax (814) 226-5568 Customer Service: Ext.#818 W TY PLEASE READ YOUR WA II NTY VERY CAREFULLY All merchandise is guaranteed for a period of six (6) years from the date of initial acceptance of the product by the contractor or the owner against defects in material and workmanship in the merchandise. All claims must have proof of purchase. If within the warranty period any such product shall prove defective of material defects, manufacturing defects, labor defects, it shall be repaired or replaced at the manufacturer's option. EXCLUSIONS: 1) This warranty shall not apply to incorrect operating procedures, breakage or damages caused by fault, carelessness, negligence, abuse, misuse, misapplication, improper maintenance, alteration, or modification of the unit by or for the buyer, as well as chemical or natural corrosion, fire, act of god, or any other casualty. 2) The buyer of the product covered by the present warranty is entirely responsible for its proper installation and connection. Clarion Bathware neither installs nor supervises or contracts for the installation and consequently cannot be held responsible for it. 3) This warranty does not apply to units or equipment not installed and connected in accordance with manufacture's instructions and in conformity with all local and state for such installations. CLARION BATHWARE IS NOT LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGE, LOSS OF TIME, INCONVENIENCE, INCIDENTAL EXPENSES, LABOR OR MATERIAL CHARGES OR ANY OTHER COSTS RELATED TO THE APPLICATION OF THE PRESENT WARRANTY OR IN CONNECTION WITH REMOVAL OR REPLACEMENT OF EQUIPMENT OR TUB. 5) All Clarion Bathware modules have slip -resistant textured floors. The use of "suction -cup" bathmats can cause surface damage. 6) Clarion Bathware makes no express warranty and no warranty of merchantability. No warranty of fitness for particular purposes or any other warranty implied or statutory for its products other than specified above. "Clearly A Difference" Page 5 of 5 SHR -A Clarion ADA-Complian, Roll -in S nower w/ 3/4" nresholc 61 -1H -A larion Bathware MP6333BF34 ELEVATION 3114 in [800 rnm] 1 in [25 min] Nailing Flange 0334 in [86 mm] Drain E on A 63 in [1600 mml PLAN 63" 11600nimd Barrier -Free Shower w/ 3/4°' 11 9m ml Threshold CENTER DRAIN --SECTION A -A PRODUCT SPECIFICATION: * Special installation instruction for this unit must be followed carefully. * Product complies with NAHB, HUD UM -73A, & ANSI -Z124.1.2. * When properly accessorized and installed, product will meet requirements of ADA (2010 Std), ICC/ANSI A 117.1-2009, ABA or UFAS. * Product has a Class B fire rating as determined by ASTM E-84 test method. * Reinforced & slip resistant floor. * Integral 1" [25mm] nailing flange. * Integral 1" [25mm] floor nailing flange. * Shower Area: W- 60" [1524mm] D- 31-1/4 (794mm] * Door Opening: W- 60" [1524mm] H- 75-3/4" [1924mm] * All dimensions =1- 1/4" [6.4mm] * Clarion Bathware reserves the right to change design and/or dimensions. * Dimensions are the same for RE, MP, and all other versions of this model. 6333BF34 63" [1600mm] Barrier -Free Shower w/ 3/4" [l9mm] Threshold & Center Drain BATHWARE 44 Amsler Ave. Signatures For Approval: Phone: (814) 226-5371 Customer: Toll Free: (800) 576-9228 Areb./Engr: Fax: (814) 226-0730 Date: DWG. it 6333BF34 -CUT Quote #: By: NMH Shippenville, PA 16254 tvmv.clarionbathware.com lob Name: Date: 5/22/20 I 11 1N I N111111211..., 1141 41 Vor-aar 1,1,,,,p4Irlts ROI bo Autrb. ihoett,o. 0`,Im 44441 41 09,, to.. 4141 4.8,-.4.1. Ispe: I..41 dacd 41,c it. pa.6.1.4.,,, forr 44444104r 1410 m gcr.1114144 hvit414 41410.44114041440,,,at Pair.1 4..1,0 m v,104:91,ordna.r. 0.,..ltkr a .10,4141k depoN14424.1.44, 4011, Ole on 111, n.ing 4414 411 4(444 do rmi h 411Fri..1.755. 414 41 010 s44o iryst10440,.11/ Chrum klAdImure,,a/ 40 11141 4 3 406,1 4'5,tv,),:ti. SHH-A hware MP6333BF34 BATHWARE Right Hand Version (MP6333RBF34) Shown We recommend all units with a 3/4r' threshold use the available collapsible threshold. MP6333LBF34 or MP6333RBF34 63° 11 600mmJ Barrier Free Shower w/ 3/4° 119mm) Threshold & Center Drain RECOMMENDED ACCESSORIES 50442TS Grab :l 0-2 1 SD FOLD NGAT i BATHWARE Fax: (814) 226-0730 44 Amsler Ave. Shippcnville. PA 16254 www.clarionbathware.com Phone: (814) 226-5374 Toll Free: (800) 576-9228 Signatures For Approval: Customer: Arch./Engr:', Quote #: Job Name: ^•IhIIR7LLtiT n'oaCf•;�.... Date: DWG. MP6333LBF34 or RBF34 -150 lava NMH Date_ 8/ 18/2014 Clown lulluasae resnres 0 c riglil In d•an4e h':e Jedgn 41.:u dmro+.;rae dA. liecduth ai aiie 000 Thi, Jravmag may have lana up,lRed +ino< Ilia ruhlieaiWn aas bacd.. R clan phony, an nade. for anw pa bull, n(er to mu 'nela:ilr al wma.daolenhahnaaci[an to uhta'n Ih[ niul curr[rt dnxangs for ar; preJvcu that pva .N:h to parchas[. Cunirarr the Jalc ul rnllon adlhe JJnxing 111.11 y41, haw will the one an the drawingear,Anile fi sw'u to+d•:9.h du ,N nc00S.irNr.011ANNU, 41,044Ato UM., i#JahIM'Y+b"e egrAtrmalt al I-000+-576-.01.:0, books ShKA Clarion Bathware MP6333BF34 ADAAG & ANSI -A117.1 COMPLIANT & BARRIER FREE 3/4" THRESHOLD SHOWER INSTALLATION INSTRUCTIONS Rev. #: 12/20/12 Key Points to remember during installation 1. The subfloor must be 100% flat, level and free from obstructions of any kind. 2. When installed, the drain of the shower and the piping must be centered on the core or box out prepared in the subfloor. Check to make sure that the core is drilled deep enough (At least 2") for the drain fitting that you are using, and that nothing will prevent it from allowing the floor of the unit to rest on the subfloor as designed. Please note that the drain pocket of this shower will protrude below the subfloor as shown in Figure 2 in this manual. 3. In buildings with a poured in place floor, make sure that there is no lip at the edge of the drain box out area. 4. If installing the drain fitting prior to installation of the shower, precautions must be taken to keep the shower from resting on the drain fitting. Failure to do this may cause warping or cracking of the shower floor. 5. When plumbing, there should be no fittings installed on the drain pipe within 2 1/2" of the top of the subfloor. This will interfere with the drain fitting and cause the floor of the unit not to rest on the subfloor as designed. 6. To meet full compliance with ADA the front edge of the seat must be within 3" [76mm] from the edge of the finished shower pocket. This must be considered when framing the pocket for the unit WARNING: FAILURE TO FOLLOW THESE INSTALLATION INSTRUCTIONS COULD VOID THIS PRODUCTS WARRANTY. The 3/4" threshold is a very sensitive unit to properly install. It is very important that the procedures are followed exactly during the installation process to create the ideal barrier free access area. A licensed plumber is required to install or supervise the installation of these units. These units are thoroughly tested in the plant to ensure their ability to drain water properly. Failure to follow these handling and installation instructions may cause improper drainage, thus voiding the unit's warranty. Clarion Bathware's Barrier -Free Showers with 3/4" Threshold are to be stored in a dry area prior to installation to prevent moisture from attacking the reinforcement material which could cause warpage to the unit. Additionally, the units cannot be stored in a manner where the bottom of the unit and the drain are forced upward. 0 SHHA Clarion Bathware MP6333BF34 Unit Preparation Remove all factory -shipping packaging and braces. On the bottom of the back wall there is a piece of OSB board for shipping purposes. This needs to be cut down so that it will not interfere with leveling the shower stall properly. To do this, set a circular saw to cut a 7/16" deep cut. Cut the OSB that extends past the bottom of the unit. Use caution when cutting, there are wood blocks that are secured with metal staples on the inside edge of the board. ***This board should not be removed until the unit is ready to be installed. Removal of the board before installation may void the warranty.*** Figure 1 Frame a square and plumb pocket to dimension of the unit. The floor of the pocket must be prepared perfectly flat and level to obtain proper drainage. If there are any obstructions, you will need to chisel or cut the concrete out to create a surface that allows for proper slope to the drain. Depending upon the core opening in the concrete slab, the installer may find it necessary to core a larger and/or deeper opening permitting adequate clearance for the draM. An 8" core at least 2" deep may be desirable. If the core cut is larger than 8" x 8" or 8" diameter, we recommend back filling the core cut, sloping the fill to the drain. This will assure that the area of the floor around the draM receives proper support Fig. 1 L !vet W, 8" x 8' or 8" Dia. Core at least 2" deep must be drilled on center with the drain to permit the drain area to be pulled down by the plumbing connection. The drain must be aligned in the center of the core to insure proper installation and drainage slope. H= Height of framing pocket should be at least the height of unit that Flg 1.1 is being installed. * W= Width of framing pocket should be no wider than the width of the unit being installed. Shims may be required. " D= Dimensions provided on the cutsheet of the unit which show the drain location. NOTE: Accommodations should be made in the pocket dimensions for any accessories attached to the unit. For ADA Compliant 36" Transfer Showers: The front edge of the seat must be no more than 3" [76mm] from the compartment entry. To achieve this with Clarion Bathware's units, the front gelcoat surface of the unit must be no more than 1-1/2" [38mm] from the finished wall in front of the shower. This will need to be taken into consideration when framing the pocket. (See Figure 1.1 & Figure 1.2) Pocket dimensions and draM location can be obtained from your retailer or at www.clarionbathware.com/search (1) enter model number of the unit then click search, (2) select the product picture, (3) select product cut sheet pdf at bottom right of the page. 61 -1H -A Clarion Bathware MP6333BF34 Figure 2 & 3 Install the drain and make sure that it is sealed properly and not leaking. Test fit the unit into the framed pocket. Check that the drain is not resting on anything which can force the unit floor upwards. Level and plumb the unit. Attach the front two vertically flanges with one fastener. Using a pencil mark all flanges on the studding. This will assist when setting the unit into the bedding compound. Remove the unit and prepare a bedding compound for the unit to be set into. Fig. 2 Below is a cross-section view of the subfloor, Studding for the back bedding compound, and the floor of a Clarion wall of the unit.-..„ Bathware Barrier -Free 3/4" Threshold Shower stall. If this area is larger than 8, It should be backfilled with bedding compound to support the area of the unit's floor around the drain. Drain Fitting The space between the bottom of the unit and the sub -floor must be filled with bedding compound in order to properly secure the floor of the unit. Concrete or wooden subfloor **FOAM SHOULD NEVER BE USED AS A BEDDING MATERIAL. ** A proper bedding compound would be cement slurry, thin mortar mix, setting type drywall compound, or lightweight gypsum plaster. Although all the listed products are acceptable, Clarion Bathware recommends using lightweight gypsum plaster for optimal results. In addition to being a user friendly product to use it also has a slow curing time and a compression rating of about 700 PSI. Two brands of this plaster to look for are Gold Bond Gypsolite Plaster and US Gypsum Structo-Lite Plaster. Mix the bedding compound to a manageable consistency. If the bedding material is too thick it may not spread out properly and can cause the unit floor to be forced up. If the bedding material is too thin it may seep out from under the unit. This can cause improper support of the unit floor. After mixing the bedding material to a consistency of "cool -whip". place it onto the floor in mounds keeping in mind the area around the drain will be thinner due to the slope of the shower floor. Placing the bedding material in mounds reduces waste and over application which may causc the unit to drain improperly or not at all. When the unit is set onto the mounds, they will spread out easier than trying to completely cover the entire floor. Small void areas of 2"-3" are not a problem as the shower floor has sufficient strength to bridge them. 611HA Clarion Bathware MP6333BF34 NOTE: The right side of the studding is omitted From this flgure to simplify the illustratiom Set the unit in the bedding compound. Align the flanges of the unit with the pencil marks. Check that the unit is plumb and level then attach each vertical flange with a fastener so that the unit won't shift. Check the floor of the shower for high spots that could restrict the water drainage. High spots in the bedding compound under the floor can be worked out by applying pressure to the area. The threshold of the unit should be fairly flat with no depressions. A slight rise is acceptable as long as proper slope to the drain is maintained. This unit has an integral floor -nailing flange. This flange was designed to eliminate floor warpage that is common with most 34 inch shower units. This flange must be attached to the floor, before the bedding material cures, to allow the unit to drain properly. If the floor nailing flange was shimmed, insure that the shims are still in place and that the floor nailing flange is still level. A screw should be inserted in the middle of the flange, and screws should be placed every 12" to each side, or as necessary to make sure that there are no bows or bumps in this flange. To attach the nailing flange to a cement floor, predrill and counter sink the fiberglass flange to accommodate concrete anchor screws. Tapcon cement screws may be used but be careful not to over tighten them, Anchor screws with expansion adaptors are the prefen-ed method to secure the flange to the floor. Please note that the use of any mechanical nailing gun can cause damage to the fiberglass flange and is not a recommended means of securing this flange to the floor. Use of any mechanical nailing gun may result in voiding the unit's warranty, After securing the floor flange re -check that proper slope has been achieved in the shower floor. Assure that there are no dips, humps, or other restrictions in the shower floor which will prevent proper water drainage 61111—A Clarion Bathware MP6333BF34 Figure 4 When the unit is plumb and level, and the slope to the drain is assured, finish securing the flanges with galvanized nails or screws. (In an application where the unit is installed over wall board and will be installing a Clarion Bathware Trim Kit, for best results your fasteners will need to be flush with the nailing flange. Clarion Bathware recommends centering and counter sinking a corrosion resistance fastener on the nailing flange. Raised fasteners will result in a problematic finishing process of the trim kit.) Final Notes: A floor -leveling agent can be used to smooth the transition between the shower unit and the floor. A smooth transition between the shower unit and the floor is a requirement for ADA compliance. We recommend Feather Finish for all vinyl applications or grout for tile installations. You can finish off your new unit with a variety of materials which are accepted by local building codes. Some ideas are tile, drywall caulking, drywall mud, plaster, wood or plastic trim. Clean your new tub with a liquid detergent and warm water. Do not use any abrasive cleaners such as scouripe powder or liquid abrasive cleaners. 611K -A Clarion Bathware MP6333BF34 IF A BEDDING MATERIAL IS USED UNDER A UNIT; CEMENT SLURRY, THIN MORTAR MIX, PLASTER OF PARIS, OR A COMPARABLE FLOOR FILLING COMPOUND THAT IS NOT WATER SOLUBLE ARE PROPER BEDDING COMPOUNDS. WATER SOLUBLE MATERIALS, FOAM AND OTHER EXPANDING MATERIALS ARE NEVER TO BE USED AS A BEDDING COMPOUND. IF YOU HAVE ANY QUESTIONS REGARDING INSTALLATION OF YOUR CLARION BATHWARE PRODUCT, PLEASE CALL OUR CUSTOMER SERVICE DEPARTMENT AT 1 (800) 576-9228 EXT. #818 OR BY E-MAIL AT CUSTOMERSERVICE@CLARIONBATHWARE.COM JOB SITE INSTALLATION OF OWNER SUPPLIED ACCESSORIES All Clarion Bathware units purchased with supplied grab bars are custom reinforced at the factory to accommodate the mounting of said bars. Any grab bars installed on a Clarion Bathware unit at the job site must have proper reinforcement (wood support and backing plates) al all mounting areas and should comply with ANSI A117.1, Uniform Federal Accessibility Standards (UFAS) and ASTM F446 specifications for grab bars in the bathing area. Job -site installation of third party supplied grab bars is entirely at the risk and full responsibility of the owner. Any damage to Clarion Bathware units or the property during or after grab bar installation, or any injuries due to improper installation remain the sole responsibility of said owner and cannot be attributed to Clarion Bathware, Inc. ESU'r I -ST AT T CUSTOMER ID CUED (RUSE'\ TER TAI NaISRBIIS'TERIN TO}T VO USIN BAT 1I MAT IN T11' IN SH SURFACE NI A Ol~TI CLARION BATHWARE PRODUCTS ARE CERTIFIED TO MEET NAHB STANDARDS, HUD/FHA, BOCA, HUD UM -73A, ANSI Z124.1 AND ANSI Z124.2. FOR DETAILS, REQUEST NAHB RESEARCH CENTER CONFIRMATION. 44 Amster Avenue Shippenville, PA 16254 (814) 226-5374 (800) 576-9228 Customer Service: Ext. #818 Fax: (814) 226-0730 www.clarionhathl ware.cont SI -11-{-A Clarion Bathware MP6333BF34 CLARION BATHWARE 44 Amsler Avenue Shippenville, PA 16254 Phone (800) 576-9228 Fax (814) 226-5568 Customer Service: Ext.#818 WARRANTY PLEASE READ YOUR WARRANTY VERY CAREFULLY All merchandise is guaranteed for a period of three (3) years from the date of initial acceptance of the product by the contractor or the owner against defects in material and workmanship in the merchandise. All claims must have proof of purchase. If within the warranty period any such product shall prove defective in material defects, manufacturing defects, or labor defects it shall be repaired or replaced at the manufacturer's option. EXCLUSIONS: I) This warranty shall not apply to correct operating procedures, breakage or damages caused by fault, carelessness, negligence, abuse, misuse, misapplication, improper maintenance, alteration, or modificationof the unit by or for the buyer, as well as chemical or natural corrosion, fire, act of god, or any other casualty. 2) The buyer of the product covered by the present warranty is entirely responsible for its proper installation and connection. Clarion Bathware neither installs nor supervises or contracts for the installation and consequently cannot be held responsible for it. 3) This warranty does not apply to units or equipment not installed and connected in accordance with manufacture's instructions and in conformity with all local and state codes for such installations. CLARION BATHWARE IS NOT LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGE, LOSS OF TIME, INCONVENIENCE, INCIDENTAL EXPENSES, LABOR OR MATERIAL CHARGES OR ANY OTHER COSTS RELATED TO THE APPLICATION OF THE PRESENT WARRANTY OR IN CONNECTION WITH REMOVAL OR REPLACEMENT OF EQUIPMENT OR TUB. 5) All Clarion Bathware modules have slip -resistant textured floors. The use of "suction -cup" bathmats can cause surface damage. 6) Clarion Bathware makes no express warranty and no warranty of merchantability. No warranty of fitness for particular purposes or any other warranty implied or statutory for its products other than specified above. "Clearly A Difference" LECESSE MI CONSTRUCTION The Power of Partnership Subn Job: 14-0298 Stone Quarry Apartments 400 Spencer Road Ithaca, NY Spec Section Title: Plumbing Submittal Title: Plumbing Fixtures PD Subcontractor:Kennedy Mechanical Primary Contact: Mark Jensen Phone Number: 585-232-2800 Supplier/Manufacturer: If this box is checked this submittal may differ from the plans and specs. Notes: FOR OWNER AND S.W.A REVIEW AND APPROVAL General Contractor: LECESSE Construction Services LLC Spec Section No: 220000-4 Submittal No: Revision No: RO Sent Date: 11/3/14 Required From Sub: 10/20/14 Approved By Architect: 75 Thruway Park Drive West Henrietta, NY 14586 Ph : 585-334-4490 Subcontractor Stamp LECESSE Stamp I HAVE PERSONALLY REVIEWED THIS SUBMITTAL AND IN MY ESTIMATION THIS DOCUMENT FULFILLS THE INTENT OF THE PLANS AND SPECIFICATIONS AND IS APPROVED FOR SUBMISSION. LECESSE CONSTRUCTION SERVICES LLC BY: Jason Socola Architect/Engineer Stamp Digitally signed by Scott Reynolds Scott Reynolds Ni otReynolds,=Ithaca Neighborhood Serivces, Housing Inc., ou, email=sreynolds@ithacanhs.org, c=US Date: 2014.11.03 13:13:30 -05'00' Mansfield Plumbing Irie-A 30-3173 Round Front, Vitreous China, Two -Piece Toilet Features • 3 bolt tank -to -bowl connection •Q28 gpf .86 Ipf low water consumption • Uses 20% less water than conventional toilets • Round front bowl • 3" hybrid flush valve • Pilot operated fillvalve • 12" rough -in • Color -match trip lever • 2" glazed trapway • The Mansfieldlimited lifetime warranty • Available in white and standard colors: biscuit, bone Model 130-3173 Toilet seat not included 'Also available as a complete toilet package. Components Model # Description 130-3173 Round front, two-piece toilet. Less toilet seat and supply. Specify color. Round front toilet bowl only. Less toilet seat. Specify color. 3173 Tank and cover only, with left hand, front -mount, color -match trip lever, Pilot valve. Less supply_ Specify color. 3173RH Same as model 3173, with right hand, color -match trip lever. Less supply. Specify color. Same as model 3173, with tank liner. 3122 3121 3121RH 3120 3120RH 04130CTK • 4130LICTK SB100 Same as 3173 with Fluidmaster pilot valve and hybrid flush valve. Same as 3121 with right hand trip lever. Same as 3121 with chrome trip lever. Codes/Standards Same as 3120 with right hand trip lever. Round front, (1.28 Gpf/1.86 Lpf) complete toilet kit. Includes toilet seat, tank and bowl, flange bolts, wax ring with polyethylene flange and instructions. Same as 4130CTK, with tank liner Alto Round, toilet seat. Specify color. Protted 0 USA 5:5.1 0 4550P.1111.1,0n Prodtictl. &LC lansfield Plumbing oh1si 1.1.0 • Customer Service Toll Free 87743SO-3060 • Fax 415-938-6234 wahsher'www,manslieldaltarbintycara Email: custserv@martsfieldplumbing.com MADE IN USA VICA Mansfield Plumbing 130-3173 Model # Description 130-3173 Specifications Round front (1.28 gpf/4.86 Ipf} two-piece toilet Specification Codes/Stan mauttnatuteivcr rdcer Description Specification Description Material Water Pressure Range Flush System Vitreous China 20 to 80 PSI Trap Diameter Trap Seal 2-5/8'' 3" hybrid flush valve Rough -in Water Usage 1.28 gpf / 4.86 Ipf 12" Shipping Weight Model 130 - 48 lbs., Model 3173 - 33 lbs., Model 4130CTK and 4130LTCTK - 85 lbs. Water Surface Area MaP Rating 600 grams Warranty Vitreous China - Limited Lifetime Tank Trim - Limited One Year Technical information See our complete line of acrylic and vitreous china bathroom fixtures, plas-tic tank trim and plumbing products. These dimensions are nominal and subject to change without notice. Fixture performance and specifications meet or exceed ASME A1(2.192.2005/C5#. 04 5.1.05 standards, and other state and local codes, Printed in U.5.5. 5/14 522011 Mansfield Plumbing Products, LLC th--- Finished Wair ' (356mm( 9-1(2' 041 rnm) 214" 4s,r0 mme- 11-101° (256 matt •—•5162* (429 mos) TT 12' 109 mm) 29° P37 nmu 14-314' 075 were (305 nun) Finished Runt di N.P.S. Supply Tne (10 mine 052 inint nes _ MADE IN USA Mansfield Plumbing Products LLC • Customer Service Toll Free 877-850-3060 • Fax 419-938-6234 Website: www.mansfieldplumbing.com • Email: custserv@mansfieldplumbing,com books VVU—A Jones Stephens 01010 comfort'Mseats u lrer c (pub), turd crn+t/nrr meet 1" Seat shall be Comfort Seats Model Number C1O1O • Builder grade residential round closed front ring design with cover • Injection molded durable polypropylene plastic with UV protection • Molded in bumpers • Matching adjustable hinge • Corrosion proof nuts and bolts • Top mount design • Specify white, bone or biscuit C1010 Profile Corrosion proof, self -aligning hardware Factory -installed `living" hinge. 5 '2` 1 /2 8 Sil 6' 9 13!1 6 fP / 1 4 3x16" Product Specifications Series: Residential Model Number: 01010 Seat Type: Round - Closed front with cover Hinge Design: factory -installed "living" hinge Ring Thickness: 1 /2" Ring Thickness with Bumper: 9/16" Height of Seat with Cover: 1 15/16" All seats feature UV protection. 17 Jones .Stephens 'o . brand PHONES E.631 d45-JC1NE5 FA7ir 844-162.'6991 wc-p Mansfield Plumbing 137-3173 137-3173 Alto® 1.28 SmartHeightTM, Elongated Front, Vitreous China, Two -Piece Toilet Features • 3 bolt tank -to -bowl connection • SmartHeight' (16-3/4" high bowl) for maximum comfort • 1.28 of / 4.86 1pf low water consumption • Uses 20% less water than conventional toilets • Elongated front bowl • 3" hybrid flush valve • Pilot operated fill valve • 12" rough -in • Color -match trip lever • 2" glazed trapway • The Mansfield') limited lifetime warranty • Available in white and standard colors: biscuit, bone Model 137-3173 Toilet seat not included *Also available as a complete toilet package. Components Model # 14/ 31) 1 Description Codes/Standards SmartHeight'', elongated front two-piece toilet. Less toilet seat and supply. Specify color. 137 SmartHeightl", elongated front toilet bowl only. Less toilet seat. Specify color. 3173 Tank and cover only, with left hand, front -mount, color -match trip lever. Pilot valve. Less supply. Specify color. 3173RH 3122 3121 Same as model 3173, with right hand, color -match trip lever. Less supply. Specify color. Same as model 3173, with tank liner. Same as 3173 with Fluidmaster pilot valve and hybrid flush valve 3121RH Same as 3121 with right hand trip lever. 3120 Same as 3121 with chrome trip lever. 3120RH Same as 3120 with right hand trip lever. ADA *41370.K SmartHeight'" elongated front, complete toilet kit. Includes toilet seat, tank and bowl, flange bolts, wax ring with polyethylene flange and instructions, *4137LICTK I Same as 4137CTK, with tank liner. Printcd in U.S.A. 5/1 ZOI : Yrodwa6, LLC MADE IN USA Ii.kinslield Plumbing Products LLC • Customer Service Toll Free 577-350-3060 • Fax 419.938.6234 Website; www.mansfieldplumbing.corn • Email; custserv@mansfieldplumbIng.torn Mansfield Plumbing 137-3173 137-3173 manstteld Alto® 1.28 SmartHeight'', Elongated Front, Vitreous China, Two -Piece Toilet Model # 137-3173 Specifications Description SmartHeight'', elongated front (1.28 gpf/4.86 1pf) two- piece toilet Specification Material Description Codes/S acta C04:s' ADA Specification Water Pressure Range Vitreous china Trap Diameter 20 to 80 PSI Flush System Water Usage Water Surface Area 3" hybrid flush valve Trap Seal Rough -in Description 2" 2-5/8" 12" 1.28 gpf / 4.86 1pf 9" X 10" MaP Rating 600 grams Shipping Weight Warranty Model 137 - 56 lbs. Model 3173 -34 lbs Models 4137CTK and 4137LTCTK - 92 lbs. Vitreous China - Limited Lifetime Tank Trim - Limited One Year Technical Information See our complete line of acrylic and vitreous china bathroom fixtures, plastic tank trim and plumbing products. These dimensions are nominal and subject to change without notice. Fixture performance and specifications meet or exceed AWE 2112 192-2008/C5A 845.1-08 standards, and other state and local codes. Printed in 45 A 8/24 42 2014 Mansfield Plumbing Products, LLC Finished Wall 5-1/2Typ. --- (140 mol). 3/-1' --le (19 mrn) 4 -131/4'—'--sic 337mm) i(j j ITI.1/2" /9 MO 31-3/4° 1-8,11414« (905 mm) t2 nwn) I14-1/2' (368mm) 10" )(1 (254nom) 9-1/2' Toilet Footprint 19-3/4' 1522 nion) 3 ° (7137 mm) 16-2/4' (425 mm) 12' (305 mm) /203 min) Top 3/8" (10 mmi (1526mm) N.P.S. Supply Typ. Finished Floor MADE IN USA Mansfield Plumbing Products LLC • Customer Service Toll Free 1377•950-3060 • Fax 413-938-6234 Websitei wwwmansfieldplumbing.com • Email; custserv@mansfieldplumbing.com VV U-1:3 Jones Stephens C1011 lylwre (pain, and crm fir ;11t,e1T" Seat shall be Comfort Seats Model Number C1011 • Builder grade residential elongated closed front ring design with cover • Injection molded durable polypropylene plastic with UV protection • Molded in bumpers • Matching adjustable hinge • Corrosion proof nuts and bolts • Top mount design • Specify white, bone or biscuit C1011 Profile Corrosion proof, self -aligning hardware Factory -installed "living" hinge. 18 5/16" 18 14 3/16" • 11 3/8" Product Specifications Series: Residential Model Number: C1011 Seat Type: Elongated - Closed front wilh cover Hinge Design: Fociory-installed "living" hinge Ring Thickness: 1/2" Ring Thickness with Bumper: 9/16" Height of Seat with Cover: 1 15/16" All seats feature UV protection. comforfsea s s Stephens Corp. Inland PHONE: K*3554437 (35-JONIS) FM: 800-462-6491 ir /0- LAV -A Cleveland Faucet Group CA47711L LEVELAN CA47711L FAUCET Of5M u 01610 A Moen Incorporated Brand lagstoe-rtt----- SP UPC® u\ii67,09 , One Handle Lavatory Faucet Without Waste 11 EY 11- A R Models: 1H Lav with 50/50 waste CA47713L 1H Lav less waste DESCRIPTION Metal construction with various finishes identlf led by suffix Includes 50/50 pop-up type waste assembly where noted 1/2' IPS connections Will accept standard cone/bevelled connection for 3/8' tubing Six (6) individual boxes per master carton OPERATION Pivot action, lever style handle Temperature control by 90arc international red/blue markings Frow IS limited to 1,5 gpm ittax, c5,7Lirrtint at PO psi, ortwatittets-tirtiattestitatorieis ,•0 lbw611AI 2,2 gpm max. (8.3L/min) CARTRIDGE • Ceramic disc technology • Non-metalllc. non-ferrous. and plastic material • Single body construction for easy replacement STANDARDS • Third party certified to WaterSensex,C5A 5-125.1. ASME A112.18.1. and all applicable requirements referenced therein including NSF 61/9 Contains no more than 0.25% weighted average lead content Complies with Calitornla Proposition 65 and with Inc Federal Safe Drinking Water Act ADA 12) for lever handle WARRANTY - RESIDENTIAL. COMMERCIAL One year limited warranty against defects in materials and manufacturing workmansnlp Refer to the installation Instructions enclosed with each CFG product Or call 1-88B-450-4910 ror complete warranty Information CRITICAL DIMENSIONS • NOTE This faucet Is designed to be Installed through 3 holes. l' minimum diameter, 4' centers Maximum deck Mickness 1,375' (35 mm) - Spacer provided. discard spacer 11 deck thickness exceeds 0,625' (15,9 mm) CRITICAL DIMENSIONS 45.1 CLEVELAND FA( 10E r GROUP • 25300 AL MOEN DRIVE • NORTH OLMSTED, 01-110 41070 .18681150-5522 www.cfgaillIne corn CFG.55-CA47711L5P•Fil 1/]! fifitet) CLEVELAND r A C E T 6•1.,zlitaRt.::' 0 LI A Moen Incorporated Brand LAV -b Cleveland Faucet Group CA47713L Models: CA47711L 1H Lav with 50/50 waste 1H Lav less waste CA47713L One Handle Lavatory Faucet Without Waste DESCRIPTION • Metal construction with various finishes identitied by suffix • Includes 50/50 pop-up type waste assembly where noted 1/2" IPS connections - Will accept standard cone/beverled connection for 3/E3" tubing Six (6) Individual boxes per master carton OPERATION • Pivot action, lever style handle • Temperature control by 90arc - International red/blue markings Flow IS limited to 1.5 gpm max. (5.7L/m(n) 3( 60 ps17) 1.preeeteger-zootrnowggitmme to 4. gpm max., t8.3L/mini CARTRIDGE ceramic cusp technology • Non-metallic, non-ferrous, and plastic material • Single body construction MI easy replacement 6° (51rorn) (Moe/ STANDARDS Third party certified to WaterSense•Ti CSA 13-125.1, ASME A112,16.1. and all applicable requirements referenced therein Including NSF 61/9 Contains no more than 0.25% weighted average lead content • Complies with Caffitornta Proposition 6 d with the • Fecisr.alSale-Detniting Water Act for lever handle WARRANTY SIOENTIAL. COMMERCIAL • One year limited warranty against defects In materials and manufacturing workmanship Refer to the installation instructions enclosed with each CFG product Or call 1-886-450-4910 for complete warranty Information CRITICAL DIMENSIONS • NOTE: This faucet Is designed to be Installed through 3 noies. 1' minimum diameter. 4' centers • Maximum deck thickness 1,375' (35 mm( - Spacer provided, discard spacer if deck thickness exceeds 0.625M 5 9 rnmi CRITICAL DIMENSIONS lC,' CLEVELAND FAUCET GROUP • 25300 AL MOEN DRIVE NORTH OLMSTED. OHIO 44070 (8881 450-5522 • wvo,v,cfgonlIne cern CFG-55-CA477I1L5P-Fti /1) books rk6-A Elkay CR33 2-4 latLJ<ArEled Celebrity° Double Bowl Sink SPECIFICATIONS Model CR3322 141,4 GENERAL Good quality sink formed of #20 gauge, type 304 (18-8) nickel bearing stainless steel. Self -rimming top mount. DESIGN FEATURES Bowl Depth: 7. Coved Corners: 3'' vertical and 2-1/4" horizontal radius, Bowl and Faucet Deck Recess: 3/16" below outside edge of sink. Finish: Exposed surfaces are polished to a highlighted Celebrity bright satin finish. Underside: Fully undercoated to dampen sound and prevent condensation. OTHER Drain Opening: 3-1/2. NOTE: Unless otherwise specified, sink is furnished with 4 faucet holes as illustrated. Complies with ASME A112.19.3. These sinks are listed by the International Association of Plumbing and Mechanical Officials as meeting the requirements of the Uniform Plumbing Code, C$h. This sink is listed with the Canadian Standards P Association. OPTIONAL ACCESSORIES Rinsing Basket: LKWERBSS. Utensil Caddy for Rinsing Basket: LKWUCSS. Bottom Grid: LKWBG1415SS, Cutting Board: CB1516, SINK DIMENSIONS (INCHES)* Model Number CR3322 Overall L 33 22 Inside Each Cowl L W 0 14 15-Y4 7 'Length is lett to right Width is front to back. 4 41 41 Cutout In Countertop (11h" Radius Corners) L W 324-li 21111 No. of 11/2" Faucet Holes 4" Centers 1, 2. MR2, 3, or 5 \ 4 4-1/4' 22" 15-3/4" 7' 15-1/4" Model CR33224 Illustrated Minimum Cabinet Size 36 Model CR33224 HOLE DRILLING CONFIGURATIONS MR2 4" 40 ALL DIMENSIONS IN INCHES, TO CONVERT TO MILLIMETERS MULTIPLY BY 25.4. lo heaping with our pokey of cooltiming.mod.rcr improver1,5111. Etkay :0500/95 The right to change This specification describes an Elhay product with design. filially in7rj fwicijona/ bvieriis to the proauct specifIcabons wharf mina, user When making a comparison al 0/her pro-lucers' °Hennas. bo certaln these features arc not overfaahed. Elkay elkayusa.com 2222 Camden Court Oak Brook, IL 60523 Printed in U.S.A. 02007 Elkay (Rev. 10/07) 1-15D K5—A Cleveland Faucet Group CA40513 CA4O513'; cles.Less,,4p,,rj es it spray A Moen incorporated Brand NSF SP UPC® One Handle Kitchen DESCRIPTION Metal Construction with various finishes Identified by suffix Hydrolockia Connection (for models built after November 20101 1/2' IPS connections Six (6) Individual boxes per master carton OPERATION • Pivot action. lever -style handle Temperature control by 90' arc Will Operate with less than 5 lbs. of torque Spout flow limited to 2.0 gpm (7.6 L/min) at 60 CARTRIDGE • Ceramic disc technology • Non-metallic. non-ferrous, and plastic material • Single bogy construction for easy replacement NOTE CA4051 1 series 15 designed to Install througr) 3 holes 1-1/4' (32mm) MIN, DIA. and 4' (102mm) on center STANDARDS • Third party certified to ASME A 1 12.18.1/CSA 8-125.1. and all applicable requirements referenced therein, Including NSFG I /9 • Contains no more than 0.25% average weighted lead content • Complies with California Proposition 65, and the Federal Safe Drinking Water Act • Feature red/blue not/cold temperature Indicators • ADA Q for lever handle WARRANTY— RESIDENTIAL, COMMERCIAL • Ten year Ilmited warranty against defects In materials and manufacturing workmanship • Refer to the Installation Instructions enclosed with eacn CFG product or call 1-088-450-4910 for complete warranty Information CRITICAL DIMENSIONS 100 NOT SCALEI The use of aerator part 1 1671 1 reduces. flow to a maximum of 1.5 gpm (5.7L/min.) CLEVELAND FAUCET GROUP ' 25300 AL MOEN DRIVE- NORTH OLMST•ED.OHIO 44070- CFG - 40511 sp - Res. 12/11 Hydrolock' is a registered trademark of COOPER STANDARD AUTOMOTIVE INC. •boo s '1.1°ICAW SPECIFICATIONS KS -E3 Elkay CR3322-4 Celebrity(' Double Bowl Sink Model CR3322 GENERAL Good quality sink formed of #20 gauge. type 304 (18-6) nickel bearing stainless steel. Self -rimming top mount. DESIGN FEATURES Bowl Depth: 7". Coved Corners: 3" vertical and 2-1/4" horizontal radius. Bowl and Faucet Deck Recess: 3/16" below outside edge of sink. Finish: Exposed surfaces are polished to a highlighted Celebrity bright satin finish. Underside: Fully undercoated to dampen sound and prevent condensation. OTHER Drain Opening: 3-1/2". NOTE: Unless otherwise specified, sink is furnished with 4 faucet holes as illustrated. Complies with ASME A112.19.3. fril:1114 These sinks are listed by the International Association of Plumbing and Mechanical Officials as meeting the V*4t) requirements of the Uniform Plumbing Code, Cih. This sink is listed with the Canadian Standards P Association. OPTIONAL ACCESSORIES Rinsing Basket: LKWERBSS. Utensil Caddy for Rinsing Basket: LKWUCSS. Bottom Grid: LKWBG1415SS. Cutting Board: CB1516, SINK DIMENSIONS (INCHES)* Model Number CR3322 Overall L W 33 22 Inside Each !howl L W 0 14 153/4 7 Cutout In Countertop (1'/f' Radius Corners) L W 3241.1 2111a 'Length N lell to right Width is front la back 4 44 4' No. of 11/a" 131a. Faucet Holes 4" Centers 1, 2. MR2, 3.1Iof 5 Model CR33224 Illustrated Minimum Cabinet Size 36 Model CR33224 HOLE DRILLING CONFIGURATIONS ALL DIMENSIONS IN INCHES, TO CONVERT TO MILLIMETERS MULTIPLY BY 25.4. hoopips2 wee OW poesy of bamboo/keg produce heepokeeenced, 91key eeSePeen the o'gt9 ed change prockeol specitionflOOS U601014 nOii170, This specific -aeon describes an allay peeve! nvith design. quality and beFlefils lo the L/Sidt When rnalkog somparison 01 othor producers' rli/cralgs, be ceefeeee thO00 ifiRtUrr:s aro ni-JI overlooked, Elkay elkayusa.com 2222 Camden Court Oak Brook, IL 60523 Printed in U.S A. ©2007 Elkay (Rev. 10/07) 1-15D ato,alaTiaaa. DLEVELAWD KS -13 Cleveland Faucet Group CA40513 " Model: CA405aliaitseries Less Sore, CA40513 series With spray. FAUCET r41 -0 U A Moen Incorporated Brand EFREIESTOFIE NSF UPC. One Handle Kitchen DESCRIPTION Metal construction wltfl various finishes Identified by suffix Hydrolock# Connection ((or models built after November 2010) 1/2" IPS connections Six (6) individual boxes per master carton OPERATION • Pivot action. lever -style handle • Temperature control by 90 arc Will operate with less than 5 lbs of torque Spout flow limited to 2.0 gpm (7.6 Urnin) at 60 psi CARTillbGE • Ceramic disc technology • Non-metallic, non-ferrous, and plastic material Single body construction for easy replacement • NOTE • CA40511 series Is designed to Install through 3 holes 1-1/4' (32mm) MIN. DIA. and 4' (102mml on center STANDARDS • Third party certified to ASME A112.18.I/CSA B -125.I. and all applicable requirements referenced therein, Including NSF61/9 Contains no more than 0.25% average weignted lead content Complies with California Proposition 65. and the Federal Safe Drinking Water Act Feature red/blue not/cold temperature Indicators ADA lor lever handle WARRANTY - RESIDENTIAL, COMMERCIAL • Teri year limited warranty against defects In materials and manufacturing workmanship • Refer to Inc Installation Instructions enclosed with each CFG product or call I-868-450-4910 for complete warranty information CRITICAL DIMENSIONS ( DO NOT SCALES The use of aerator part 116711 reduces flow to a maximum of 1.5 gpm (5.7Umini) CLEVELAND FAUCET GROUP • 25300 AL MOEN DRIVE • NORTH OLms-rEo. °Hip 44070• (868)4 0.5522 - wvAvacald‘I'l neaCOrr1 CFG 4051Isp - Rev. 12/1) Hydgclock° is a registered trademarkk(C05 EltiTANDMID AUllatablIVE INC b0C3kS, kr,:, Supply Corp TUB Cleveland Faucet Group 40311 CGR SPEC C A T Model: O A Moen Incorporated Brand SP. Trims for Pressure ; alancing Cycling In -Wall Valve w/Water-Saving Showerhead 40311 C R H E E T 40315CGR Series DESCRIPTION • Metal construction with chrome plated or LlfeShlne° Brushed Nickel finishes • 40315CGR—shower only trim • 40311 CGR—tub/shower trim w/ slip fit tub spout • Twelve (12) Individual boxes per master carton OPERATION • Rotating style metal lever handle • Temperature control by 150° arc • Will operate with less than 5 lbs of torque • Metal escutcheon features track printed polycarbonate overlay with red/blue International temperature marking • Protective gaskets surround Interior and exterior rim • Weep hole located at bottom of escutcheon • Slip fit tub spout connects to 1/2" pipe with bottom 5/32" set screw IRS tub spout connects to 1/2" mips pipe • Showerhead limited to 1.75 gpm (6.65 L/min) at 80 psi '— CRITICAL DIMENSIONS 51.10WEAHEAD STAT A 70.11902mm) ESCUTCHEON HANDLE -- TUD SPOUT 42' 11067mm1 TUD AIM �ffi IN -WALL VALVE SOLD SEPARATELY • 45311 CC/Male IPS with stops • 45312 CC/Male IPS • 45317 Female IPS with stops • 45318 Female IPS • 45319 PEX connections STANDARDS • Third party certified to WaterSense, ASME A112.18.1 /CSA B-125.1, and all applicable requirements referenced therein • IAPMO Green Listed • Features red/blue hot/cold temperature Indicators • ADA la for lever handle WARRANTY — RESIDENTIAL, COMMERCIAL • Ten (10) year limited warranty against defects In materials and manufacturing workmanship • Refer to the Installation Instructions enclosed with each CFG product or call 1-888-450-4910 for complete warranty Information 65' (165mm1 ESCUTCHEON DIAMETER FACE OE FINISHED WALL --\. STANDARD SHOWER ARM 7W 119112mm) HANDLE -- TLJASPOUT 4r11067mm) 1UB RIM 30.1767mm) THIN WALL THICK WALL CLEVELAND FAUCET GROUP • 25300 AL MOEN DRIVE • NORTH OLMSTED. OHIO 44070 • (686) 450-5522 • www.cfgonllne.com CFGSS-PBT-C- R3/ I 0 !..:AL -01011 CLEVELAND UB Cleveland Faucet Group 45312 ,viimmwelfritelfea . I/33..-t•W-A.DIA/2,60,-DA•23.6126,4AA.x. Model: 45312 FAUCET 054,11'142 0 UA Mon kcorported Brand t2170 0 --fR El E 1:R S T 0 El ET" UPc® Pressure Balancing Cycling In -Wall Valve DESCRIPTION • Brass construction • 1/2" connections: IPS - exterior CC - Interior • Pressure balancing 4 port cycling valve • 11\evelve (12) individual boxes per master carton OPERATION • Pressure balancing mechanism maintains selected discharge temperature to A-- 2°F • Adjustable temperature limit stop to control maximum hot water • For use with stud thicknesses 2-1/2" or greater CARTRIDGE • European ceramic disc technology • Non-metallic, non-ferrous, and plastic material CRITICAL DIMENSIONS — TUB SURROUND 2.5" (633mml STANDARDS • Third party certified to ASME A112.18.1/CSA B125.1, ASSE, and all applicable requirements referenced therein, California Proposition 65, Illinois, Massachusetts, and Texas WARRANTY • Ten (10) year limited warranty against defects In materials and manufacturing workmanship • Refer to the installation instructions enclosed with each CFG product or call 1-888-450-4910 for complete warranty information. 42 (1067mm) / TDB USE In' COPPER OP IPS PIPE ONLY 2_1' CC (S3mm) 2..0" IPS (50mml I 10" PEX (50rnon) MAX WALL 5' (1 FINISHED WALL FACE FLOOR FACE OF STUD 30 MIN. CC 113rnml .625 MIN. PEX I16mml .625 MK IPS (16mrn1 2.6" (66mmI SO° (13mml 42° I 043m76 THIN WALL THICK WALL CLEVELAND FAUCET GROUP - 25300 AL MOEN DRIVE NORTH OLMSTED. OHIO 44070 (858)450-5522 - www cfgonlIne.com CFG-55-PBC-R12/11 tC13 MOEN® COMMERCIAL DESCRIPTION Chrome plated metal construction Pressure balancing cycle valve design with 1/4 turn stops / • Contains: hand-held shower with non -positive pause, 30" slide b ( drop ell, • vacuum breaker, 69" metal hose and mounting hardware Slide bar is NOT DESIGNED TO BE A GRAB BAR Supplied with vandal resistant screws • Quick cleaning rubber nozzles OPERATION • Temperature valve has ADA compliant lever style handle • Handle operates counterclockwise through a 270' arc with off at 6 o'clock, and maximum hot at the 9 o'clock position. Shut off in clockwise direction • Adjustable temperature limit stop • Pressure balancing mechanism maintains selected discharge temperature to ± • Single function spray pattern • Easy to operate pause button (reduces the flow of water to a trickle) FLOW 8346EP15 (1.5gpm/5.7 Ipm); WaterSense' Certified • 1222HD brass cartridge design • Brass construction with stainless steel materials • Accommodates back-to-back Installations STANDARDS • Third party certified to ASME A112.18.1/CSA 13125.1 and all applicable requirements referenced therein • ADA 0, for lever handle WARRANTY • Warranted for 5 years against material or manufacturing defects 2" Dia, 1/2-14 NP 0 ) 1/2-14 NPSL ' THREAD Rev. 11/12 I 5!16' SPRAY HEAD DIAMETER Breaker DROP ELL 8-1'8" (.21361‘.4 SPRAY VAN() HEIGH I TUB RIM 25-112" NON1imAL (123111(11) FINISHED WALL LINE FLOOR LINE 2" Diameter 1/2-14 NPT 1/2-14 NPSL THREAD - (178mm) ESC DIAtvl. DIRECTION OF HANDLE ROTATION 3-6 (1981mm) NOMINAL (SI IOW ER -13 S ecifications Single -Handle Pressure Balancing Shower Valve With Hand -Held Shower System 8346, BUY ACT COMPLIANif FINISHED WALL LINE DROP ELL -- 1/2" MIN. CC (13namS 5/8" P51I /16" (21mm) SEE NOTE BELOW - 2 1/2" MAX, (63min) ESCUTCHEON 4-112" (114mm) PLASTER GUARD OPENING CRITICAL DIMENSIONS (DO NOT SCALE) HANDLE 1, 6..6" 1981mm) NOMINAL - 3" (76mmi MIN. WALL CAVITY 45" (1143) 4Er (1219mm) NOMINAL FLOOR LINE MOEN SPECIFIER SERVICES 1-800-321-8809 Ext. 2158 www.moen.com MECHANICAL FAUCETS 897 -RCF Manual Faucets Product Type Wall Mounted 8" Body, Adjustable Arms 7 5/8" - 8 3/4" Hot and Cold Water Sink Faucet Features & Specifications • 8" Body, Adjustable Arms 7 5/8" - 8 3/4" • 2-3/Er Vandal Proof Lever Handle • Quaturn Compression Operating Cartridge • 1/2" NPT Adjustable Female Union Nut Supply Arms • 3/4" Male Hose Thread Outlet • Round Wall Escutcheons • Integral Stop Valves for Servicing the product • Atmospheric Vacuum Breaker, Not Intended for Continuous Pressure Applications • Vacuum Breaker Spout with Pail Hook and Wall Brace • Atmospheric Vacuum Breaker, Not Intended for Continuous Pressure Applications • CFNow! Item Ships in 5 Days Performance Specification • Rated Operating Pressure: 20-125 PSI • Rated Operating Temperature: 40-140°F Warranty • Lifetime Limited Faucet Warranty • 5 -Year Limited Cartridge Warranty • 1 -Year Limited Finish Warranty Codes & Standards • ASME A112.18.1/CSA B125.1 • ADA ANSI/ICC A117.1 MOP SINK Chicago Faucet8974RCF CHICAGO.", FAUCETS Gebarit many Job Name Item Number Section/Tag Model Specified Architect Engineer Contractor [ [Submitted as Shown [ J Submitted with Venetians Dale Last Revision: 10/12/2011 • Date Printed: 09123/2014 • Product specifications subject to change without notice 2100 South Clearwater Drive Des Plaines, IL P: 8471803-5000 F. 847/803-5454 Technical: 800/TEC-TRUE www.chicagoraucels.com 897 -RCF Manual Faucets Architect/Engineer Specification MOP SINK Chicago Faucet 897 -RCF CHICAGO FAUCETS a Gebant carapaily Chicago Faucets No, 897 -RCF, Wall Mounted 8" Body, Adjustable Arms 7 5/8 - 8 3/4 Hot and Cold Water Sink Faucet , Rough Chrome plated solid brass construction. Vacuum Breaker Spout with Pail Hook and Wall Brace. 2-3/8 Metal Vandal Proof Lever handle(s) with Sixteen Point Tapered Broach and Secured Blue and Red Buttons. QuaturnT" rebuildable compression cartridge, opens and closes 90°, closes with water pressure, features square tapered stem. 1/2 NPT Adjustable Female Union Nut Supply Arms. 3/4" Male Hose Thread Outlet, Round Wall Escutcheons, Integral Stop Valves for Servicing the product. Atmospheric Vacuum Breaker, Not Intended for Continuous Pressure Applications. Atmospheric Vacuum Breaker, Not Intended for Continuous Pressure Applications, Secondary Control Valve: Vacuum Breaker Spout with Pail Hook and Wall Brace., 31.1' MALE GAADIN (..„., HOSE THILEAO rwmito WALL 2 ILA' 154mmi LEI 226L-rol 4' 02mmi 129.mml 316 PE% SOCKEI INLLGNAL SUPPLY STOPS Operation and Maintenance I2GOLEB11 I/?'NPI FEMALE 5113LAO INLET 2,3141PLILLAN 012, RANGE 34Bisml 13116 ° RAmm1 1•114' 2-5/B° 132mm BA7m1 OVAL FLANGE BIO HO' FLAT HEAD WOOD5CNEW 1102mm) 7 2- SILO' 11-jimm.2131Bm1 AallE5TABLE SUPPLY ANAIS Installation should be in accordance with local plumbing codes. Flush all pipes thoroughly before installation. After installation, remove spout outlet or flow control and flush faucet thoroughly to clear any debris. Care should be taken when cleaning the product. Do not use abrasive cleaners, chemicals or solvents as they can result in surface damage. Use mild soap arid warm water for cleaning and protecting the life of Chicago Faucet products. For specific operation and maintenance refer to the installation instructions and repair parts documents that are located at wilw.chicanofaucets.com. Chicago Faucets, member of the Geberit Group, is the leading brand of commercial faucets and fittings in the United States, offering a complete range of products for schools, laboratories, hospitals, office buildings, food service, airports and sport facilities. Call 1.800.TECTRUE or 1.847.803.5000 Option 1 for installation or other technical assistance. 2100 South Clearwater Drive Des Plaines, IL P: 847/803-5000 F: 847/803-5454 Technical: BOO/TEC-TRUE www.chicagoraucels,com Last Revision: 10/12/2011 • Date Printed: 09/23/2014 • Product specifications subject to change without notice ok MUSTEE MOP SINK ustee MU63114 --- 7 Mop Service Basin — Model 63M Code Accepted Design features: ▪ All Mustee basins are one-piece molded from high impact resistant DURASTONEv structural fiberglass (24" x 24") • integral, molded -in draM for connection to 3" ABS, PVC (Sch. 80) or cast iron • Available drain seals for connection to 2" pipe or 3" soil pipe • Complete range of accessories to meet specific application needs Colorfast marbleized white finish • Easy to install Mustee Mop Service Basins meet or exceed performance requirements as listed: • International Association of Plumbing and Mechanical Officials (IAPMO)® Listed • Warnock Hersey' (Canada) Listed—CSA test standards: Mop Basins - NB45.0 • American National Standards Institute (ANSI) -Specification Z124.6 • American Society of Testing and Materials (ASTM) D 635 E 84 and E 162 • CAN/ULC S102-07 Burn and Smoke Test Specifications Model Number Model HxWxD UPC 63M White 10" x 24" x 24" General: Furnish and install as shown on plans, Mop Service Basin model 63M. as manufactured by EL. Mustee & Sons, Inc. Unit to be one-piece molded fiberglass made with matched metal molds using extreme heat and pressure. Height shall be 10" with not less than 1" wide shoulder. Size 24" x 24': Drain shall be Integrally molded, complete with draM seal for installation of 3" ABS. PVC (Sch. #80) and iron pipe. Removable stainless steel strainer. Performance tested lo meet or exceed ANSI Specifications Z 12412, Z 124,6 and FHA/ HUD UM -71 Weight 45 lbs, cubic feet 42 Install in compliance with local codes. MUSTEE Sectional View ---- 24" —1 -- 10" 6 71031 00189 4 Top View 2 °' tr-12".- 24" EL Mustee & Sons, Inc. • 5431 West 164th Street • Brook Park, OH 44142 • Phone: 216.267.3100 • Fax: 216.267.9997 E-mail: Inlo@mustee.corn_ • Web: www.mustee.com • Proudly made in the USA Nano: Our ennlinuous commiirnent io product improvement may roniin oi chringec 0, product specilicintions WilIloul noFice, Pawls pending. Made arid Printed in U.S.A. LPA WaterSense Builder Name: Version 1.1 WaterSense Labeled New Home Inspection Checklist Version 1.1 WaterSense® Labeled New Home Inspection Checklist Lot Number/Street Address/Unit Number: City, State, Zip: pection Informati Inspection Company: Inspector Name: Date: Time Started: Time Completed: Sampling Protocol Information Is this home being sampled and inspected as part of a sampling protocol for multiple homes in a planned community, subdivision, or multi -family building? Were the first seven homes in this planned community, subdivision, or multi -family building all directly inspected and certified? Was this home randomly selected for sampling from a group of seven homes that are scheduled for completion within 30 days of one another? (Provide additional information as indicated below For the homes covered by this sampling protocol.) Building Information Is the home being inspected as a unit within a multi -family building? If yes, are all applicable building requirements met? (Provide responses to the requirements listed below.) Item Metering Common use clothes washers 3.9 3.7.2 Prerequisite Multi -Family Building Criteria Water metering/tracking for each unit ENERGY STAR® qualified Water factor 5 6.0 Notes on Multi -Family Building Criteria Y+ N Req. By affixing my signature below, I do hereby declare that I have inspected the home in accordance with the Version 1.1 WaterSense New Home Specification and the Version 1.1 Inspection and Verification Guidance for WaterSense Labeled New Homes and will provide, if requested, the necessary supporting documents. Inspector Name: Signature: Company: Date: * Not installed (NI) Documentation required (Req.) to be provided by the builder August 30, 2012 WaterSense Version 1.1 WaterSense Labeled New Home Inspection Checklist Home or Unit Criteria Indoor Water -Efficiency Criteria Leaks Service pressure Hot water delivery Toilets Flushing urinals Bathroom sink faucets Kitchen sink faucets Showerheads Dishwashers Clothes washers Evaporative cooling system Water softeners Drinking water treatment s stems 3.1 3.2 3.6 3.8.1 Pressure -loss test on all water supplies detected no leaks No visible leaks from hot water delivery system No visible leaks from toilets/urinals No visible leaks from bathroom faucets No visible Teaks from kitchen faucets No visible leaks from showerheads No visible leaks from other fixtures or appliances Single-family: Pressure tank installed and set 5 60 psi OR Single-family: PRV installed upstream of fixtures and pressure test 5 60 es' OR Single family: Pressure test 5 60 psi and written documentation from water supplier that pressure <_ 60 psi Multi family: Pressure test 5 60 psi Acceptable system type 10°F temp. change within 5 0.6 gallons WaterSense labeled WaterSense labeled WaterSense labeled Measured flow rate—max 1.5 gpm (Flow test maximum: 0.25 gal) Measured flow r x 2.2 goni (Flow test maximum: 0.4 gal) WaterSense labeled Measured flow rate—max 2.0 gpm water per shower compartment 5 2,160 in2 Flow test max: 0.35 .al/com.artment Separate controls for showerheads if > 2160 int ENERGY STAR qualified Water factor 5 6.0 Acceptable system type Maximum 3.5 sal/water/ton hour cooling, max 3 blowdowns/24 hr Controls blowdown through conductivity or a basin temperature - based controller Certified to NSF/ANSI Standard 44, including voluntary efficiency ratinstandards in Section 7 NSF/ANSI certified, minimum efficienc ratin. 85% Req MINIM Req. Req. Req. Req. Req. Req. Req. Notes on Indoor Water - Efficiency Criteria Not installed (NI) t Documentation required (Req.) to be provided by the builder 2 August 30, 2012 L PA WaterSense Version 1.1 WaterSense Labeled New Home Inspection Checklist Item Outdoor Water -Efficiency Criteria Landscape design Slopes Mulching Pools/spas Ornamental water feature Irrigation system Home or Unit Criteria Single-family: Front yard landscaped 4.1 All improved upon areas landscaped 4.1.1 4.1.1.1 Temporary landscape installed Landscapable area of lot <_ 1,000 ft2 and exempt from landscape design criteria Water budget tool calculations verified Landscape complies with water budget design 4.1.2 Slopes z 4:1 are vegetated 4.1.3 4.1.4 4.1.5 4.2 No exposed soil All mulch is 2 to 3 inches deep Single-family: Cover installed Multi -family: Independently metered Multi -family: Gutter or grate system Req. Req. Multi -family: Sorptive media or cartridge filtration system Recirculates water and serves beneficial use Weather -based irrigation controllers or approved soil moisture sensor -based controller; weather -based irrigation controllers shall be WaterSense labeled as of June 1, 2013 Multi -family: Independently metered Designed or installed by WaterSense irrigation partner Provided waiver for design/installation System audited by WaterSense irrigation partner Req. Req. Irrigation System Audit Checklist completed by WaterSense irrigation partner Provided waiver for audit Notes on Outdoor Water -Efficiency Criteria Not installed (NI) t Documentation required (Req.) to be provided by the builder 3 August 30, 2012 LPA WaterSense Item Home or Unit Criteria Homeowner or Resident and Building Management' Education Criteria Single-family/ occupant operating manual Building operating manual Irrigation system Pools/spas 5.2 5.3 5.2 4.1.4 Version 1.1 WaterSense Labeled New Home Inspection Checklist Written operating and maintenance manual (or chapter) for all water -using equipment/controls installed in house, unit, yard, or common use outdoor area General information on water -efficient dishwashers and clothes washers if they are not installed Multi family: Manual for all water -using equipment and controls outside of individual dwellings or inside of individual dwellings that are maintained by building management Schematic, itemized list of irrigation components, copies of irrigation schedules, and information on reprogramming schedules included in operating manual for homeowners of single family homes and for building managers for multi- family buildings Multi family: Detailed information on filtration equipment and manufacturer's recommended maintenance schedule to building management Notes on Homeowner Education Criteria Not installed (NI) Documentation required (Req.) to be provided by the builder Yes NI Doc' 4 August 30, 2012