HomeMy WebLinkAboutLecesse O and Ms - Division 10Ph : 585-334-4490
75 Thruway Park Drive
West Henrietta, NY 14586
14-0298
Stone Quarry Apartments
400 Spencer Road
Ithaca, NY
Submittal
Revision No:
Sent Date:
334000.2
Submittal No:
Spec Section No:Job:
Required From Sub:
Approved By Architect:
10/20/14
Spec Section Title:Sirk
Submittal Title:Storm Sewer Structures PD/SD
Subcontractor:
Primary Contact:
Phone Number:
Supplier/Manufacturer:
If this box is checked this submittal may differ from the plans and specs.
Notes:
Subcontractor Stamp
LECESSE Stamp
Architect/Engineer Stamp
LECESSE Construction Services LLC
General Contractor:
IHAVEPERSONALLYREVIEWEDTHISSUBMITTAL
ANDINMYESTIMATIONTHISDOCUMENTFULFILLS
THEINTENTOFTHEPLANSANDSPECIFICATIONS
ANDISAPPROVEDFORSUBMISSION.
LECESSECONSTRUCTIONSERVICESLLC
BY:DrewJohnsonJason Socola
Jeff Fancher/ Andrew Cupicha
J&R Specialties
716-442-5040
Interior & Exterior Signage
Signage
101419 & 101423
2/25/15
R0
Various
Aluminum letter is
approved.
Signage Color should
be 'Taupe' for the
background and
'White' for the
foreground.
✔
date:cba 04-27-15
13661 Main Street
Akron NY, 14001
Phone: (716) 442-5040 Fax: (716) 442-5044
Submittal Cover Sheet
Date - 1/22/15
Project - 14-0298 Stone Quarry Apartments, Ithaca NY
Spec. Section - Panel Signage Spec. Sect. 101423
*Spec. Sect. 101419 will be submitted separately*
Product - Interior and exterior signage for the apartment build ing and
townhouses.
Manufacturer - Holland Engraving
Notes- Attached please find: 1. Sign Schedule, 2. H400 Series Cut
sheet. 3. Holland Engraving Brochure (4 pages) 4. Holland
Engraving Color Chart. 5. Holland Engraving Limited
Lifetime Warranty document.
Please select one color for the border and letter/numbering and a
different color for the background. We will provide physical color
samples upon request.
First Submission
Re-Submission
BY:
Andrew Cupicha
Project Manager
J&R Specialties, Inc.
13661 Main Rd.
Akron, NY 14001
Phone (716) 442-5040
Fax (716) 442-5044
Cell (585) 993-7203
ARCHITECT / ENGINEER STAMP
ACTUALSIGN TO READROOM# 100S 100J 100H 100A 100D 100G 100F 100E 100B S100 100CQUANTITY1111111111111COLORSIGN TYPE2344444414214ACTUALSIGN TO READROOM# 100S 121M S200 200E 200M 200S 200JQUANTITY1111111111111COLORSIGN TYPE1114211144214ACTUALSIGN TO READROOM# 200T S300 300T 300J 300SQUANTITY1111111111111COLORSIGN TYPE4111211144121ACTUALSIGN TO READROOM# 300N 300EQUANTITY1111222222222COLORSIGN TYPE4411555555555ACTUALSIGN TO READROOM#QUANTITY22222223363COLORSIGN TYPE5555555 4627** # OF CHARACTERS DEPICTS SIZEHighlighted boxes denoted sign verbage that will be determined in the field.TYPE 7 BUILDING IDENTIFICATION SIGNS 18" X 12" STYLE H400105 108 109EXTERIOR PLAQUE ID106 107ELEVATOR 228 JANITORSTORAGE STAIRS 329MECH BSTORAGEJANITORSTAIRSSTAIRS335FL. ID SIGNS IN STAIRWAYELEVATOR 330 331 101RESTROOM, 6" X 8" MEN / WOMAN / UNISEX - WITH SYMBOL, Style H400113112 114 115 1166" x 6" STANDARD STAIR & FLOOR ID, Style H400 APARTMENT UNIT ID 4" X 3" Style H400TYPE 1TYPE 2TYPE 3IN CASE OF FIREDIRECTIONAL SIGN 111110102 103STORAGE 227 226 225 STAIRS 332 333 334STORAGE104119 120 121 JANITOR STAIRS 224 223 222J&R SPECIALTIES, INC.JOB NAME:Stone QuarryCONTRACTOR:LecesseeSTAIRS RESTROOMCOMMUNITY ROOMMECH AELEVATOR MECHLAUNDRY OFFICE ELEVATOR 117 118 MECH CTYPE 5 TOWN HOUSE 6" x 6" EXTERIOR UNIT ID SIGNS, STYLE H400TYPE 6 DIRECTIONAL SIGNS OUTSIDE OF ELEVATOR, 10X4 STYLE H400(7 ) TRUSS ID SIGNS WILL BE FURNISHED AND INSTALLEDTYPE 4 STANDARD ROOM NAME, 8X3, 10X3, 8X4, 10X4 ** STYLE H400
400 Series Submittal Sheet
Standard Room #
3x4
Standard Unisex Restroom
Pictogram
6x8
Standard Room Name
3x8, 3x10, 4x8 & 4x10
*number of characters depicts size
400
ADA COMPLIANT GRADE 2
BRAILLE
Lettering: Larger than .625”
Material: Single ply, modified acrylic;
1/16” thick backer, 1/32” thick lettering
Finish: “Matte, non-glare, ADA”
Engraving Method: Laser and rotating
carbide
Usage: Interior and exterior signage
Physical Properties:
ADA Substrate material softens
sufficiently at about 200°F (93.33°C),
which enables bending, should that be
desired. It can also be drilled, sawed,
sheared, nailed and
bonded to itself or other materials.
The material was tested for flammability
by Underwriters Laboratories. The
materials are rated 94 HB on the UL 94
test. The material was judged as not
contributing to
the combustion of the base material.
Tensile Strength: 5,500 psi
Rockwell Hardness: M45
Akron NY
Standard Stair & Floor ID
6x6
STAIRS
RESTROOM
056
*MOST COLORS ARE AVAILABLEEXTERIOR APPLICATIONS ENGRAVED APPLICATIONS
Red/White
Yellow/Black
SIZES AVAILABLE
Up to 12” x 24”
4”x3”*
GARAGE I.D.
SIGNS
6”x6”*
UNIT I.D. SIGNS
18”x12”*
BUILDING IDENTIFICATION SIGNS
VFRIVRIIIF
TRUSS I.D. SIGNAGE
Identification of Building Construction for Fire Fighter Safety
• Mounted Directly to a Door
• Mounted to an 8”x8” Aluminum Backer and Can be Mounted Directly to the Building
• A full list can be viewed at HollandEngraving.com
Exterior grade 1/8” thick acrylic
can be pre-drilled for mounting
H•400:
DIRECTORIES
H•400: 10”x4”
DIRECTIONAL SIGNS
H•400: 6”x6”
STAIRWAY SIGNS
H•400: 6”x3” Width as Req
ROOM NAME
ELEVATORELEVATOR
ELEVATOR
RESTROOMRESTROOM
RESTROOM
womenWOMEN
WOMEN
MENMEN
MEN
womenWOMEN
WOMEN
MENMEN
MEN
6”x8”6”x8”6”x8”6”x8”6”x8”6”x8”
H•200: 6”x6”
FLOOR I.D. INSIDE A
STAIRWAY TO IDENTIFY
WHICH FLOOR YOU ARE ON
H•200: 6”x6” Standard
ROOM NAME OR NUMBER
W/ 2 WINDOWS*
*Name inserts by others
H•200: 6”x6” Standard
ROOM NAME OR
NUMBER W/ WINDOW*
*Name inserts by others
H•200: 4”x3”
ROOM NUMBER
Apartment Unit ID
TH Unit ID
orders@HollandEngraving.com
1.800.532.1541
• All interior signage can qualify for LEED credits
• Holland Engraving carries a 2 year warranty on all signs
• Signs come with double-sided 3M tape
• Signs can come pre-drilled for mounting with screws
ADA Substrate material softens sufficiently at
about 200°F (93.33°C), which enables
blending, should that be desired. It can also be
drilled, sawed, sheared, nailed and bonded to
itself or other materials.
The material was tested for flammability by
Underwriters Laboratories. The materials are
rated 94 HB on the UL 94 test. The material
was judged as not contributing to the
combustion of the base material.
TENSILE STRENGTH: 5,500 psi
ROCKWELL HARDNESS: M45
PHYSICAL PROPERTIES
ADA COMPLIANT GRADE 2 BRAILLE
LETTERING: Larger than .625”
MATERIAL: Single ply modified acrylic; 1/16”
thick backer, 1/32” thick lettering
FINISH: Matte, non-glare, ADA
ENGRAVING METHOD: Laser and rotating carbide
USAGE: Interior and exterior signage
SPECIFICATIONS
Available with Squareor Rounded Corners
H200 Series
H400 Series
H600 Series
H100 Series
H300 Series
H500 Series
13661 Main Street
Akron, NY 14001
orders@HollandEngraving.com
1.800.532.1541
**Need letter & back-drop color (same
color), background color
Limited Lifetime Warranty
13661 MAIN ST AKRON NY 14001
P: 716-685-4298 ORDERS@HOLLANDENGRAVING.COM F:716-442-5044
Holland Engraving warrants that all products will be free of
manufacturing and material defects. Failure to use proper installation
methods consistent with Holland Engraving installation instructions
shall mitigate Holland Engraving of any liability.
Any Defective product will be replaced free of any charge, if a claim is
presented to Holland Engraving. Holland Engraving is not responsible
for any installation costs involved with replacements. Shipping costs
within the United States are included in replacements.
Our liability under this limited lifetime warranty is limited to
replacement and does not include any responsibility or incidental or
consequential damages of any nature.
For Customer Service:
716-685-4298
800-532-1541
orders@hollandengraving.com
13661 Main Street
Akron NY, 14001
Phone: (716) 442-5040 Fax: (716) 442-5044
Submittal Cover Sheet
Date - 2/17/15
Project - 14-0298 Stone Quarry Apartments, Ithaca NY
Spec. Section - Dimensional Letter Signage--Spec. Sect. 101419
Product - Stainless Steel-C304 Alloy, ¼” thick, brushed face
(vertical grain) Letters, 5” and 3” (as discussed)
Mounted using 3/4” stand-off SS studs.
Manufacturer - Gemini Incorporated
Notes- I have included: 1. Flat Cut Metal Letters Specifications sheet. 2. All
available manufacturer’s fonts. 3. A WORD file that will allow you to
print out a few of the letters in actual size, to determine if their sizes
will be satisfactory. 4. Additional manufacturing data.
.
First Submission
Re-Submission
BY:
Andrew Cupicha
Project Manager
J&R Specialties, Inc.
13661 Main Rd.
Akron, NY 14001
Phone (716) 442-5040
Fax (716) 442-5044
Cell (585) 993-7203
ARCHITECT / ENGINEER STAMP
1.800.538.837792
Metal Letters
Flat Cut Metal
STEEL FINISHES Note: Vertical grain is standard all all cut metal letters.
Horizontal grain can be requested.
Polishing requires a minimum of 2" height and 1/4" depth or 3" height and 1/8" depth (stud mounts
required). Restrictions may apply on letters over 24". All stainless steel letters and logos are shipped
without a clear polyurethane coating. Alloy C304 will not tarnish under most conditions. In cases
where stainless steel letters and logos will be installed in salt water environments Alloy 316 offers even
better corrosion and tarnishing resistance. Using harsh chemicals may cause permanent damage to the
materials surface.
PolishedBrushed
Add 30%
Alloy C304 Stainless
PolishedBrushed
Add 30% Add 60%
Alloy 316 Stainless Cor-Ten®
Less 30%
1/8” & 1/4” ONLY
Natural
Alloy C304 is the standard “18/8” stainless; it is the
most versatile and most widely used stainless steel.
For areas within 50 miles of the coast, Gemini recom-
mends Alloy 316. This conforms to recommendations
by numerous metal industry panels. Use of 304 in
coastal areas may experience premature failure.
Alloy 316 is the standard molybdenum-bearing grade,
second in importance to C304 amongst the austenitic
stainless steels. The molybdenum gives 316 better over-
all corrosion resistant properties than C304, particularly
higher resistance to pitting and crevice corrosion in
chloride environments.
Cor-Ten® – a weather resistant steel created by alloy-
ing copper, chromium and nickel. The material forms
its own protective layer when exposed to atmospheric
elements. Essentially, the top layer corrodes which
then protects the steel beneath it. The natural finish
does not normally require any form of maintenance
such as painting, which makes the material a highly
cost effective alternative to other structural steels.
POLISHED
Price as Listed
(#4 finish - Add 15%)
Brushed Stainless Steel letters are particularly susceptible to collecting exterior contaminants
and airborne pollutants from harsh environments. This is because the brushed stainless steel
finish catches and holds residues that can stain the surface of the letters. In many cases, we
have seen customers believe that these residues are actually rust. In most non-marine cases,
the brushed stainless steel finish simply needs to be cleaned. This can be easily accom-
plished because stainless steel letters are shipped without a clear coat—so simply by taking
a scotchbrite pad and ordinary Stainless Steel Cleaner (such as Kleen King) letters can be
returned to an “as new” condition. In cases where actual oxidation (rust) has occurred—it is
because the stainless has been exposed to marine environments or harsh atmospheres such as
being near treated chlorine pools or concentrated engine exhaust. In these cases Alloy 316 is
recommended for longer life—but may require clear coat protection to further lengthen the
lifespan of the stainless steel. Remember—stainless steel is “stain less” not “stain free”.
The picture on the top right is of a letter near a fountain that collected some residue that our
customer thought was ‘rust’. With just a paper towel and some Kleen King, it was a simple
solution to restore the sign to a perfect luster. (picture at bottom right)
NOTE ON MAINTAINING BRUSHED STAINLESS
Alloy C304 Stainless
Brushed
ST
ON
E
400
Jason Socola
cba 12-15-14
Jason Socolacolor to be Bronzecba12-23-14
®
Choose Color
051 01520
2530354045#3776#3775
Jason Socola
cba 12-15-14
Jason Socola
cba 12-26-14
Ph : 585-334-4490
75 Thruway Park Drive
West Henrietta, NY 14586
14-0298
Stone Quarry Apartments
400 Spencer RoadIthaca, NY
Submittal
Revision No:
Sent Date:
334000.2
Submittal No:
Spec Section No:Job:
Required From Sub:
Approved By Architect:
10/20/14
Spec Section Title:Sirk
Submittal Title:Storm Sewer Structures PD/SD
Subcontractor:
Primary Contact:
Phone Number:
Supplier/Manufacturer:
If this box is checked this submittal may differ from the plans and specs.
Notes:
Subcontractor Stamp
LECESSE Stamp
Architect/Engineer Stamp
LECESSE Construction Services LLC
General Contractor:
I HAVE PERSONALLY REVIEWED THIS SUBMITTAL
AND IN MY ESTIMATION THIS DOCUMENT FULFILLS
THE INTENT OF THE PLANS AND SPECIFICATIONS
AND IS APPROVED FOR SUBMISSION.
LECESSE CONSTRUCTION SERVICES LLC
BY: Drew JohnsonJason Socola
Jeff Fancher
J&R Specialties
716-442-5040
Toilet, Bath, and Laundry Accessories
Medicine Cabinets
102800-1.3-1
RESENT-12/12/14
R0
Jensen (bought Broan)
Re-sent per CBA for approval
30x30 at Apt Units, 24x30 at THs
date:cba 12-15-14
Mounting measurements for wooden doors Mounting measurements for steel doors
DD
Height adjustment ± 2 mm
Side adjustment ± 2 mm
Height adjustment ± 2 mm
Side adjustment ± 2 mm
D
66 www.grassusa.com Dimensions in millimeters, fractional inch equivalents as noted.
Tri-view-mirror hinge
90° hinge for wooden or steel doors
Hinge for wooden doors Opening angle 90°
•For medicine cabinets with wooden or steel doors
•Concealed self-locking hinge, top and bottommount, for mirror cabinets and variable angle
cabinets without partition
•Universal left and right handed assembly
Hinge cup: white plastic
Hinge arm: diecast, nickel-plated
Base plate must be ordered separately
Item No.
212.100.34.9570
PU 250 pieces
Hinge for steel doors Opening angle 90°
Hinge cup: white plastic
Hinge arm: diecast, nickel-plated
Base plate must be ordered separately
Item No.
212.100.36.9570
PU 250 pieces
Suitable base plate
diecast, nickel-plated
Item No.
511.200.04.9515
PU 250 pieces
Center plate (Optional)
Nylon center plate allows
adjustment and correct
positioning of screws.
(optional)
Item No.
514.000.51.0061
PU 250 pieces
IMPORTANT
To determine the correct
application Grass strongly
recommends a trial mounting for
all hinges and base plates.
PU = packaging unit
1
Ashley Tarasco
From :Charlie B. Ackerman <cba@holt.com>
Sent:Thursday, December 11, 2014 2:31 PM
To:Ashley Tarasco
Subject:RE: Stone Quarry Hinge information
These are acceptable.
Charlie Ackerman
Construction Administrator
HOLT Architects, P.C.
217 N. Aurora St.
Ithaca, NY 14850
phone 607 273-7600
fax 607 273-0475
cell 607-351-3061
http://www.holt.com
From: Ashley Tarasco [mailto:atarasco@LECESSECONSTRUCTION.COM]
Sent: Thursday, December 11, 2014 2:30 PM
To: Charlie B. Ackerman Cc: Jason Socola Subject: Fwd: Stone Quarry Hinge information
Charlie,
Attached are the hinges for the spec'd med cabs. The manufacturer is willing to offer a 10-year warranty as well.
Please let me know if these are acceptable.
Thank you
Sent from my iPhone
Begin forwarded message:
From: "andrew@jrbuffalo.com" <andrew@jrbuffalo.com>
To: "Ashley Tarasco" <atarasco@LECESSECONSTRUCTION.COM>
Subject: Stone Quarry Hinge information
Hello Ashley,
Here's what I received for the hinges. Please let me know how you would like me to proceed.
Thanks,
Andrew
✔
date:cba 05-11-15
(800) 233-8493 • www.c-sgroup.com Page 1 – August 2014
SUGGESTED SPECIFICATIONS
SECTION 10 26 00
C/S Acrovyn® 4000 .040N Rigid Sheet
Part 1 - General
1.01 Summary
A. This section includes the following types of wall protection systems:
1. Wall Covering
B. Related sections: The following sections contain requirements related to this section:
1. Handrails, Bumper Guards, Crash Rails, Corner Guards, Accent Rails, Wall
Panels, Door Protection; refer to section 10 26 00 “Wall and Door Protection”
1.02 References
A. National codes (IBC, UBC, SBCCI, BOCA, Life Safety and CA 01350)
B. American Society for Testing and Materials (ASTM)
C. Underwriters Laboratories (UL)
D. California 01350 specification
1.03 Submittals
A. General: Submit the following in accordance with conditions of contract and Division
1 specification section 01 33 00 “Submittal Procedures”.
B. Product data and detailed specifications for each system component and installation
accessory required, including installation methods for each type of substrate.
C. Shop drawings showing locations, extent and installation details of wall covering
products.
D. Samples for verification purposes: Submit the following samples, as proposed for this
work, for verification of color, texture, pattern and thickness:
1. Sample of each product specified.
E. Product test reports from a qualified independent testing laboratory showing
compliance of each component with requirements indicated.
F. Maintenance data for wall protection system components for inclusion in the
operating and maintenance manuals specified in Division 1.
1.04 Quality Assurance
A. Installer qualifications: Engage an installer who has no less than 3 years experience in
installation of systems similar in complexity to those required for this project.
B. Manufacturer’s qualifications: Not less than 5 years experience in the production of
specified products and a record of successful in-service performance.
C. Code compliance: Assemblies should conform to all applicable codes including IBC,
UBC, SBCCI, BOCA, Life Safety and CA 01350.
D. Fire performance characteristics: Provide engineered PETG wall protection system
components with UL label indicating that they are identical to those tested in
accordance with ASTM E84 for Class 1 characteristics listed below:
1. Flame spread: 25 or less
2. Smoke developed: 450 or less
E. Impact Strength: Provide assembled wall protection units that have been tested in
accordance with the applicable provisions of ASTM F476.
F. Chemical and stain resistance: Provide wall protection system components with
chemical and stain resistance in accordance with ASTM D543.
(800) 233-8493 • www.c-sgroup.com Page 2 – August 2014
G. Color match: Provide wall protection components that are color matched in
accordance with the following:
1. Delta Ecmc of no greater than 1.0 using CIELab color space. (Specifier note:
Construction Specialties’ colors are matched under cool white fluorescent
lighting and computer controlled within manufacturing tolerances. Color may
vary if alternate lighting sources are present).
H. Single source responsibility: Provide all components of the wall protection system
manufactured by the same company to ensure compatibility of color, texture and
physical properties.
1.05 Delivery, Storage and Handling
A. Deliver materials to the project site in unopened original factory packaging clearly
labeled to show manufacturer.
B. Store materials in original, undamaged packaging in a clean, dry place out of direct
sunlight and exposure to the elements. A minimum room temperature of 40ºF (4ºC)
and a maximum of 100ºF (38ºC) should be maintained.
C. Materials must be stored flat.
1.06 Project Conditions
A. Materials must be acclimated in an environment of 65-75ºF (18-24ºC) for at least 24
hours prior to beginning the installation.
B. Installation areas must be enclosed and weatherproofed before installation
commences.
Part 2 - Products
2.01 Manufacturers
A. Interior surface protection products specified herein and installed on the submittal
drawings shall be manufactured by Construction Specialties, Inc.
2.02 Materials
A. Engineered PETG: Rigid sheet should be high impact Acrovyn 4000 with nominal
.040" (1.02mm) thickness and supplied in 4' x 8' or 10' (1.22m x 2.44m or 3.05m)
sheet sizes in standard Suede texture. Quatro, Single Tread, Beadboard (specify
nominal 1-5/8" or 2-5/8"), Mesa, Stone Chips, Irish Linen, Pindot, Leather, Pinstripe,
Dado and Stipple textures shall be 43" x 90" or 114" (1.09m x 2.29m or 2.90m).
Select from one of (64)* Acrovyn solid colors or (18)* Chameleon patterned
colorways which include (16) woodgrains and (2) metals. Specify color-matched
caulk, plastic trims or metal trims as needed for joints/transitions. (*Specifier note:
refer to color selectors to determine which colors and patterns are Cradle to Cradle
CertifiedCM Gold or Silver.)
2.03 Fabrication
A. General: Fabricate wall covering to comply with requirements indicated for design,
dimensions, detail, finish and sizes.
2.04 Accessories
A. Acrovyn Wall Covering shall be furnished as a complete packaged system, containing
all adhesive. Adhesive shall be water based and non-hazardous. Water based primer is
also available for purchase.
(800) 233-8493 • www.c-sgroup.com Page 3 – August 2014
Part 3 - Execution
3.01 Examination
A. Verification of conditions: Examine areas and conditions under which work is to be
performed and identify conditions detrimental to proper or timely completion.
1. Do not proceed until unsatisfactory conditions have been corrected.
3.02 Preparation
A. Surface preparation: Prior to installation, clean substrate to remove dirt, debris and
loose particles. Perform additional preparation procedures as required by
manufacturer's instructions.
B. Protection: Take all necessary steps to prevent damage to material during installation
as required in manufacturer's installation instructions.
3.03 Installation
A. Install the work of this section in strict accordance with the manufacturer's
recommendations using approved adhesive.
B. Temperature at the time of installation must be between 65-75ºF (18-24ºC) and be
maintained for at least 48 hours after the installation to allow for proper adhesive set
up.
C. Relative humidity shall not exceed 80%.
D. Do not expose wall covering to direct sunlight during or after installation. This will
cause the surface temperature to rise, which in turn will cause bubbles and
delamination.
3.04 Cleaning
A. General: Immediately upon completion of installation, clean wall covering and
accessories in accordance with manufacturer's recommended cleaning method.
B. Remove surplus materials, rubbish and debris resulting from installation as work
progresses and upon completion of work.
3.05 Protection
A. Protect installed materials to prevent damage by other trades. Use materials that may
be easily removed without leaving residue or permanent stains.
INSTALLED WITH ACROVYN
INTERIORS HEAVY DUTY
WATER BASED MASTIC ADHESIVE
ACROVYN
WALL COVERING
BASE (BY OTHERS)
FLOOR (BY OTHERS)
WAINSCOT TRIM
NO LESS THAN 1"
RECOMMENDED
ABOVE FINISH FLOOR
FOR FIELD
VARIATION
3/8"
[9.6mm]
3/8"
[9.5mm]
3/8"
[9.5mm]
3/8"
[9.1mm]
3/8"
[9.5mm]
6696 Route 405 Highway, Muncy PA 17756
(800) 233-8493 Fax (570) 546-4692 www.c-sgroup.com
DOC#: TS-930- ISSUE DATE: REV DATE:08/03/10346N 10/06/14
COLOR:____________________________________________
COLOR TO BE SELECTED FROM ONE OF C/S STANDARD COLORS. CHAMELEON
PATTERNS/COLORS ARE AVAILABLE ON SHEETS ONLY. TRIMS ARE ONLY
AVAILABLE IN SOLID/BASE COLORS.
TEXTURE:__________________________________________
SUEDE TEXTURE IS STANDARD. ADDITIONAL TEXTURES AVAILABLE UPON
REQUEST. ADDITIONAL TEXTURES MAY EFFECT PRICE.
.040" ACROVYN WALL COVERING
AT PARTIAL HEIGHT
WITH ACROVYN TRIMS
NOTES:
1. STANDARD SHEET SIZES ARE 48" X 96" OR 48" X 120". TEXTURED SHEET
SIZES ARE 43" X 90" OR 43" X 114".
2. CHAMELEON PATTERN DIRECTION IS PARALLEL TO THE 96" OR 120" SIDE OF A
STANDARD SHEET, OR 90" OR 114" SIDE OF A TEXTURED SHEET.
3. ACROVYN TRIMS SUPPLIED IN 10'-0" LENGTHS.
MATERIAL QTY.
REQ'D
48" X 96"
48" X 120"
COLOR:__________________
QTY.:_____________________
OUTSIDE CORNER TRIM
(25N032xxx)
COLOR:__________________
QTY.:_____________________
INSIDE CORNER TRIM
(25N035xxx)
COLOR:__________________
QTY.:_____________________
VERTICAL JOINT TRIM
(25N033xxx)
COLOR:__________________
QTY.:_____________________
WAINSCOT TRIM
(25N036xxx)
7170Wall Guards supplied in standard Shadowgrain. Solid colored .040", .060" & .075" sheet supplied in standard Suede; .040" available in all other textures. Chameleon patterned .040" and .060" sheet supplied in standard Suede; available in all other textures. Square and Beveled Edge Wall Panels supplied in standard Suede; available in all other textures except Shadowgrain. Saratoga Wall System supplied in standard Suede; available in all other textures except Pindot, Dado, Quatro and Single Tread.Sheet and wall panel sizes vary; refer to our most current product specifications found at Acrovyn.com. Specify direction of texture for full and wainscot applications. *Beadboard available in nominal 1-5/8" or 2-5/8" texture widths. **Aluminum trims look different (view details online). 135° inside and outside corner trims available in aluminum only.LeatherSuedeMesaStone ChipsIrish LinenPindotAcrovyn Wall Covering Trim Options 3/8" Acrovyn trim pieces in 10' lengths (optional aluminum sheet trims are available in 12' lengths)Aluminum Vertical TrimVertical Trim Color-matched sealant availableWainscot Trim Optional aluminum wainscot available**Beadboard*PinstripeQuatroDadoSingle TreadStippleOptional Outside Corner Guard See pages 20-21 for optionsInside Corner Trim Optional aluminum inside corner available**Outside Corner Trim Optional aluminum outside corner available**(All textures shown are actual size.)ACROVYN® WALL COVERING & PANEL TEXTURE COLLECTION
ACROVYN® SOLID COLORS* Optional Vertical Accent Colors include: Beige, Black, Charcoal, Chinchilla and Mission White. These are available for specific Acrovyn profiles.Due to limitations of the printing process, colors above may vary. When specifying, obtain color samples by calling factory.6564253 Parchment (C2C Silver)858 Pumice (C2C Gold)517 Teton White (C2C Gold)100 Eggshell (C2C Gold)194 Chinchilla* (C2C Gold)317 Kona (C2C Gold)320 Brick (C2C Silver)321 Russet (C2C Gold)326 Rustic Red (C2C Silver)853 Ocean Gray (C2C Silver)318 Berry Red (C2C Silver)262 Driftwood (C2C Gold)223 Danube (C2C Gold)129 Yale Blue (C2C Silver)325 Cape Blue (C2C Gold)324 Underseas (C2C Gold)927 Folkstone (C2C Gold)136 Pearl Gray (C2C Gold)162 Charcoal* (C2C Gold)314 Ozark (C2C Gold)315 Galveston Gray (C2C Gold)319 Saybrook Sage (C2C Silver)323 Serene Green (C2C Gold)920 Almond (C2C Gold)101 French Cream (C2C Gold)519 Buttercream (C2C Silver)310 Yosemite Sand (C2C Gold)186 Champagne (C2C Gold)102 Desert Sand (C2C Gold)997 Irish Cream (C2C Gold)254 Wheat (C2C Gold)196 Fawn (C2C Gold)198 Beige Desert (C2C Gold)103 Beige* (C2C Gold)305 Mushroom (C2C Gold)866 Doeskin (C2C Gold)479 Cappuccino (C2C Gold)480 Toffee (C2C Gold)303 Caramel (C2C Gold)316 Chestnut (C2C Gold)193 Gingerspice (C2C Gold)307 Sienna (C2C Gold)106 Brown (C2C Silver)209 Slate (C2C Gold)311 Celery (C2C Gold)521 Spanish Moss (C2C Silver)522 Savannah (C2C Silver)660 Sage Green (C2C Gold)957 Bluestone (C2C Silver)930 Blue Silk (C2C Gold)848 Aspen (C2C Gold)520 Imperial Purple (C2C Silver)309 Tranquil Blue (C2C Gold)265 Fog (C2C Gold)108 Black* (C2C Gold)934 Pearl (C2C Gold)949 White (C2C Gold)933 Mission White* (C2C Gold)313 Vanilla (C2C Silver)322 Peanut Brittle (C2C Gold)513 Khaki Brown (C2C Gold)105 Mocha (C2C Gold)929 Oyster Gray (C2C Gold)187 Tan Bark (C2C Gold)Hundreds of custom colors have been matched, including competitor colors. Contact factory for availability.All colors are Cradle to Cradle Certified™ Gold or Silver. The C2C Gold and Silver notes on the color chips are for Acrovyn Wall Guards and Wall Covering. Call 800-233-8493 for updated color information.Cradle to Cradle Certified™ is a certification mark licensed by the Cradle to Cradle Innovation Institute. 696 Olive Grove (C2C Silver)984 Garden Sprout (C2C Gold)405 Colorado Trail (C2C Gold)874 Riverbed (C2C Gold)CHOOSE COLOR FROM BELOW