HomeMy WebLinkAboutKennedy HVAC 7-15-15LOCATIONCOMMENTSDESIGN EQUIPMENTMAXCFMTAGAFUEOACFMHPVOLT PHMOTORESP(in. wc)MCAWEIGHTSTAGES FUELHEATINGMIN. INPUT (MBH) MIN. OUTPUT (MBH) MAX. INPUT (MBH) MAX. OUTPUT (MBH)COOLING - DX EVAP. COILTMBH SMBH MODELE.A.T.D.B. L.A.T.D.B.O.A.T.D.B.NOM. CAPACITY TONSLOCATIONCOMMENTSDESIGN EQUIPMENTTAGSERVICECOMPRESSORSTAGES TYPEELECTRICALPHVOLT MCAWEIGHTARISEERAHRI MBH AHRI REF #PHYSICAL CHARACTERISTICSSYSTEM MATERIALFINISH/COLORAIR TERMINAL SCHEDULETAGCOMMENTSELECTRIC WALL HEATER SCHEDULEDESIGN EQUIPMENTCOMMENTSPHVOLTKWHEATING ELEMENTCFMAIRTYPELOCATIONTAGFURN-A 600 .9 0 96 115 1 N/A114.5NAT. GASMC18A3XC1ECM1. PROVIDE COMPATIBLE 5+2 DAY PROGRAMMABLE THERMOSTAT TO ACCOMMODATE CONTROL VOLTAGE AND FURNACE CONTROL BOARD.2.PROVIDE UNIT WITH SIDE FILTER RACK AND 2" PLEATED FILTER MINIMUM MERV 8.3.PROVIDE UNIT WITH CONCENTRIC VENT KIT.4.PROVIDE UNIT WITH CONDENSATE NEUTRALIZER KIT.5.CAPACITIES INDICATED FOR COOLING BASED ON ARI CONDITIONS AT 95°F OUTDOOR AND 80°F DB/67°F WB. INDOOR AT 400 CFM/TON. STATICPRESSURE IS BASED ON COOLING WITH WET COIL.6.FURNACE/EVAPORATOR COIL/AIR COOLED CONDENSER SYSTEM SHALL BE ARI CERTIFIED AND ENERGY STAR LISTED. ALL ENERGY STARPRODUCTS SHALL BE VERIFIABLE ON THE ENERGY STAR WEB SITE.7.PROVIDE UNIT WITH ECM FAN MOTOR AND SINGLE STAGE GAS VALVE.8.COOLING COIL, DIRTY FILTER, AND CONSTANT AIRFLOW REGULATOR ARE ALL TO BE INCLUDED AS EXTERNAL STATIC PRESSURE LOSS.1. UNIT SHALL BE COMPLETE WITH METAL BACKBOX SUITABLE FOR SURFACE OR RECESSED MOUNTING.2. UNIT SHALL INCLUDE FAN DELAY, THERMAL CUTOUT, DISCONNECT SWITCH AND INTEGRAL TAMPER-PROOF THERMOSTAT.3. UNIT TO BE FIELD CONVERTED FOR VOLTAGE AND PHASE DEPENDING ON ACTUAL SHIPPED CONFIGURATION.4. UNIT SHALL BE MOUNTED APPROX. 12" AFF TO BOTTOM.TAGCOMMENTS DESIGN EQUIPMENTSERVICEESP(in. wc)BLADETYPEDRIVETYPEFAN SCHEDULECFMMAX FANRPMMAXSONESPHVOLTMOTORWATTS CONTROLHP-EXHAUST STEEL TBD -FURNACE SCHEDULE - NATURAL GASUNIT WIDTH(IN.)AIR-COOLED CONDENSING UNIT SCHEDULEALL DWELLING UNIT FURNACESYORK TM9E040A10MP11EF-1FCEXHAUSTALL DWELLING UNITS - EXCEPT HALF-BATHS 90/30 0.10580 DIRECT 6.2 120 1 SWITCH <0.3 PANASONIC FV-05-11VKSL1,2,3,4,5-ACC-1 FURN-A1.5OUTSIDE, AS INDICATED1208 1,214.7 17.6 7142705 1 SCROLL133YORK YCJF18S41S11. PROVIDE UNIT WITH UNIT MOUNTED FAN SPEED CONTROLS. ADJUSTED TO AIRFLOW INDICATED AND PERMANENTLYMARKED AFTER FINAL AIR BALANCE. CONTROL MOUNTED IN FAN CASING.2. PROVIDE UNIT WITH INTEGRAL DISCONNECT.3.4.PROVIDE UNIT WITH ROOF JACK BACKDRAFT DAMPER OR HOODED WALL CAP AS CALLED FOR ON PLANS.FAN SHALL BE WIRED TO ELECTRICAL CIRCUIT TO OPERATE CONTINUOUSLY AT 30 CFM AND 80 CFM DURING OCCUPIED MODE.1.2.PROVIDE UNIT WITH 5 MINUTE RESTART TIME DELAY.PROVIDE UNIT WITH TXV KIT.CUH-L1CUH-S1RECESSEDSURFACE4545 21208208 1LOBBYSTAIRWELLS (2)1,2,3,4,5,71,2,3,4,6,7 QMARK HT2024SS2 QMARK HT2024SSEAV80 67 17.9 12.8 N/A N/A 40 38 9.5 113 1,2,3,4,5,6,7,8,9,10LOCATION12----4" Ø EXHAUST GOOSENECKRETURN STEEL TBDRG-A20" X 20" RETURN GRILLESUPPLY STEEL TBDSD-A4" X 12" FACE, 6"Ø NECKSTEEL TBDSD-BTOEKICK DIFFUSER, 6"Ø NECKSTEEL TBDSD-C4" X 10" FACE, 5"Ø NECKSTEEL TBDSD-D10" X 10" FACE, 8"Ø NECKSUPPLYSUPPLYSUPPLY9.FURNACES SHALL BE CONFIGURED AS FOLLOWS: DOWNFLOW UNITS AT TOWNHOMES, UPFLOW UNITS AT APARTMENT BUILDING.EF-2FCEXHAUSTALL DWELLING UNITS - HALF-BATHS ONLY, CORRIDORS 80 0.10 829 DIRECT 14.7 120 1 SWITCH <0.3 PANASONIC FV-05-11VK11,2,3,5,6-EF-3FCEXHAUSTALL NON-DWELLING UNIT LOCATIONS 80 0.10 829 DIRECT 14.7 120 1 SWITCH <0.3 PANASONIC FV-08VQ51,2,3,4,5--------5. PROVIDE PANASONIC PN#PC-RD05C4 RADIATION DAMPER AT ALL APARTMENT UNIT LOCATIONS.LOCATIONCOMMENTSDESIGN EQUIPMENTMAXCFMTAGAFUEOACFMHPVOLT PHMOTORESP(in. wc)MCAWEIGHTSTAGES SOURCEHEATINGMIN. INPUT (MBH) MIN. OUTPUT (MBH) MAX. INPUT (MBH) MAX. OUTPUT (MBH)COOLING - DX EVAP. COILTMBH SMBH MODELE.A.T.D.B. L.A.T.D.B.O.A.T.D.B.DSS-A 247 - 75 - 230 1 -123.625ELECTRICCS-KE12NB41-1.PROVIDE LCD WIRELESS-TYPE TEMPERATURE (BUILT-IN) WITH IC THERMOSTAT (BY SAME MFG.)2.PROVIDE UNIT WITH INTEGRAL FILTER.3.4.5.CAPACITIES INDICATED FOR COOLING BASED ON ARI CONDITIONS AT 95°F OUTDOOR AND 80°F DB/67°F WB. INDOOR AT 400 CFM/TON. STATICPRESSURE IS BASED ON COOLING WITH WET COIL.FURNACE/EVAPORATOR COIL/AIR COOLED CONDENSER SYSTEM SHALL BE ARI CERTIFIED AND ENERGY STAR LISTED. ALL ENERGY STARPRODUCTS SHALL BE VERIFIABLE ON THE ENERGY STAR WEB SITE.CEILING RECESSED DUCTLESS SPLIT AIR CONDITIONING SYSTEMUNIT WIDTH(IN.)CORRIDORS AT APARTMENT BUILDING, PUMPS IN ROOF RECESSPANASONIC KE12NB41 (AHRI#5052304)- - 11.9 - N/A N/A 13.6 13.6 15 35.3 123456789FURN-B 1600 .6 350 96 115 1 N/A219.875NAT. GASFC48C3XC1ECMHOUSE FURNACEYORK TM9V080C16MP11C88.4 67 46.0 33.6 52 50 80 77 11.5 136 1,2,3,4,6,7,8,95. PROVIDE UNIT WITH INCLUDED FRAME FOR RECESSED INSTALLATION.6. PROVIDE UNIT WITH SMHTSSNW SURFACE MOUNTING FRAME.7. SET INTEGRAL TAMPER-PROOF THERMOSTAT TO 50°F.FAN SHALL BE WIRED TO ELECTRICAL CIRCUIT TO OPERATE CONTINUOUSLY AT CORRIDORS, AND WIRED TO A SWITCHED CIRCUIT AT TOILET ROOMS.6.PHYSICAL CHARACTERISTICSMATERIALFINISH/COLOREXTERIOR AIR TERMINAL SCHEDULECOMMENTS-STEEL TO MATCH ROOF -----BROAN #634 10-1/4" X 10-3/4" WITH INTEGRAL BACKDRAFT DAMPER AND BIRD SCREENSTEEL BY OTHERS BROAN #647 9" X 9" WITH 7"Ø CONNECTIONALUMINUM BROAN #855AL 6-1/2" X 6-1/2" WITH 4"Ø CONNECTIONALUMINUM 18" X 8" GREENHECK ESD-202 WITH VCD-23 LOW LEAKAGE CONTROL DAMPER, TFB24 ACTUATOR, AND DRIVE-CC-11-1FEL-0 DRIVE ARRANGEMENTALUMINUMSTEEL BROAN #641FA 9" X 9" WITH 6"Ø CONNECTIONTYPEROOF CAPWALL CAP (RANGE EXH)WALL CAP (DRYER VENT )LOUVER L-1LOUVER L-2OA INTAKE WALL CAP18" X 8" GREENHECK ESD-202 WITH VCD-23 LOW LEAKAGE CONTROL DAMPER, TFB24 ACTUATOR, AND DRIVE-CC-11-1FEL-0 DRIVE ARRANGEMENT-STEEL BROAN #843BL 9" X 9" WITH 6"Ø CONNECTIONWALL CAP (BATH EXH) BY OTHERSBY OTHERSBY OTHERSBY OTHERSBY OTHERSACC-2 FURN-B4.0OUTSIDE, AS INDICATED1208 1,214.5 44.5 5434466 1 SCROLL208YORK YCJF48S41S226.3-PVC YORK #1CT0302 / 1CT0303 CONCENTRIC VENT KIT. PROVIDE FOR ALL GAS-FIRED EQUIPMENT. SIZE INLET/OUTLETS PER EQUIPMENT REQUIREMENTS.CVK (CONCENTRIC VENT) TO MATCH ROOF10.OUTSIDE AIR REQUIREMENT AT APARTMENT AND TOWNHOME UNITS SHALL BE SATISFIED THROUGH OPERABLE WINDOWS AND BUILDING INFILTRATION.GENERAL NOTES:1.ALL NOTES, SPECIFICATIONS, AND SYMBOLS ON THIS DRAWING APPLY TO ALL HVAC DRAWINGS FOR THIS PROJECT.2.HVAC CONTRACTOR IS RESPONSIBLE FOR ALL CUTTING, CORING AND PATCHING. WORK TO BE PERFORMED BY WORKERS SKILLED IN THEMATERIAL BEING CUT AND PATCHED.3.FIELD VERIFY ALL DUCTWORK AND PIPE SIZES, AND EXACT LOCATIONS.4.PROVIDE ALL WORK IN COMPLIANCE WITH ALL LOCAL, STATE AND FEDERAL CODES. OBTAIN ALL REQUIRED PERMITS.5.FIRESTOP ALL FLOOR/CEILING AND ROOF/CEILING PENETRATIONS THROUGH ASSEMBLIES THAT REQUIRE A FIRE RESISTANCERATING6.WHERE BRANCH DUCT SIZES ARE NOT SHOWN, THEY SHALL BE THE SAME SIZE AS THE DIFFUSER NECK.7.ALL DIFFUSERS SHALL BE EQUIPPED WITH A FACE-MOUNTED AIR VOLUME CONTROL DAMPER.8.INSTALL ALL EQUIPMENT IN STRICT CONFORMANCE WITH MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS.9.IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE THE WORK OF THIS CONTRACT WITH THE WORK OF ALL OTHER TRADESPRIOR TO THE FABRICATION OR INSTALLATION OF ANY WORK.10.THE DRAWINGS ARE SCHEMATIC IN NATURE. THE CONTRACTOR SHALL PROVIDE ALL OFFSETS, FITTINGS, HANGERS, ANCHORS, SUPPORTS,WIRING, AND ACCESSORIES FOR A COMPLETE AND OPERATIONAL INSTALLATION. REFER TO EQUIPMENT INSTALLATION DETAILS FOR MOREINFORMATION.11.LOCATIONS OF EACH TYPICAL WALL PENETRATION, FURNACE FLUE EXHAUST, OUTSIDE AIR INTAKE, AND TOILET EXHAUST SHALL BEALIGNED AT SIMILAR ELEVATIONS BY TYPE AT ALL APARTMENTS.12.MUCH OF THE DUCTWORK ON THIS PROJECT IS INTENDED TO BE CONCEALED WITHIN ARCHITECTURAL SOFFITS. COORDINATE THEINSTALLATION OF ALL CONCEALED DUCTWORK WITH THE GENERAL CONTRACTOR.13. ALL TRANSFER DUCTS SHALL BE 6" AFF UNLESS NOTED OTHERWISE.14.GENERAL CONTRACTOR TO COORDINATE WITH MECHANICAL CONTRACTOR SOFFIT LAYOUT.15.LOUVERED DOORS AT MECHANICAL ROOMS SHALL BE BY G.C., WITH OPEN SURFACE AREA COORDINATED WITH MECHANICAL AIRREQUIREMENTS.16.COORDINATE HEIGHT OF THERMOSTATS WITH ADJACENT LIGHT SWITCHES. THE VERTICAL CENTER LINE OF THE THERMOSTATS AND LIGHTSWITCHES SHALL BE EQUAL.SYMBOL DESCRIPTIONCUBIC FEET PER MINUTEFEET PER MINUTEEXISTINGABOVE FINISHED FLOORGENERAL CONTRACTORELECTRICAL CONTRACTORACCESS DOORTHOUSAND BTU/HOURNOT TO SCALEPLUMBING_CONTRACTORNORMALLY CLOSEDNORMALLY OPENREMOVAL KEYNOTEINSTALLATION KEYNOTECONNECTION TO EXISTINGREMOVE TO THIS POINTNCNOECPCGCNTSAFF(E)ADFPMCFMMBHABBREVIATIONS AND TAGSOED OPEN END DUCTSUPPLY AIRSARA RETURN AIROA OUTSIDE AIRFC FLEXIBLE CONNECTIONPKGD PACKAGED(L) LINEDEXHAUST AIREALOW PRESSURE REFRIGERANTLPRHIGH PRESSURE REFRIGERANTHPRCOMBUSTION AIR INTAKECAICOMBUSTION AIR EXHAUSTCAEOUTSIDE AIROAVDSYMBOL DESCRIPTIONDUCT SECTION - SUPPLYDUCT SECTION - RETURNWIDTH A x DEPTH BROUND DUCT IN INCHESFLAT OVAL DUCT IN INCHESTRANS: SQUARE TO ROUNDACOUSTIC THERMAL LININGRISE IN DUCTDROP IN DUCTDUCTWORK LEGENDA"ABAxB(L)RRDD24x1012x824x1024x1012x824x10CONICAL TEELATERALWRRW1-1/2 TIMES BRANCHSIZE12x1024x1016x108x1018x1024x1012x108x1018x1016x1012x1024x1016x108x1018x1018x1012x108x1016x1024x1020x1224x1612x1024x1612x1024x1620x1020x2020x1020x1020x2020x1090^ VERTICALSPLIT OFF(PLAN VIEW)DUCT TURNINGUP OR DOWNSUPPLY/RETURN/EXHAUST AIRTAKE-OFFSSUPPLY AIRTAKE-OFFSSUPPLY AIRTAKE-OFFSLONG RADIUS90° ELBOWR=WLONG RADIUS45° ELBOWR=WSUPPLY AIRTAKE-OFFSSUPPLY/RETURN/EXHAUST AIRTAKE-OFFS w/REGISTER/GRILLE/DIFFUSERSUPPLY DIFFUSER,REGISTER OR GRILLEOROR90° ELBOWWITH TURNINGVANESRETURNREGISTER OR GRILLEEXHAUSTREGISTER OR GRILLE1-1/2 TIMES BRANCHSIZESUPPLY/RETURN/EXHAUST AIRTAKE-OFFSSUPPLY AIRTAKE-OFFS10"10"18"18"10"10"10"10"18"18"DESCRIPTIONSYMBOLDUCTWORK SYMBOLS AND TAGSFLEX CONNECTORSDFDAADTTNECKCFMMAXMINTMINFANMAXDUCT ELEVATIONAIRFLOW DIRECTIONAUTOMATIC AIR DAMPERFIRE DAMPERSMOKE DAMPERVOLUME DAMPERBACKDRAFT DAMPERFCAIR TERMINAL UNITT = UNIT TYPEMAX = MAXIMUM CFMMIN = MINIMUM CFMFAN POWERED AIRTERMINAL UNITT = UNIT TYPEMAX = PRIMARY MAX. CFMMIN. = PRIMARY MIN. CFMFAN = FAN CFMREGISTER,GRILLE,DIFFUSERT = TYPENECK = NECK SIZE__________BDDCONTROL/SYMBOLS LEGENDDESCRIPTIONSYMBOLTEMPERATURE SENSORDUCT SMOKE DETECTORHUMIDISTATTHERMOSTATTHERMOSTAT WITH GUARDSTATIC PRESSURE SENSORFIN RADIATION (TYPE)WALL TO WALL ENCLOSUREFT-W/W ENCL.SDSDHTTGSPABCDEFGABCDEFG1234567891012345678910WARNING: It is a violation ofNew York State Law for anyperson, unless acting under thedirection of a licensed Architect,to alter this document in any way.If a document bearing the seal ofan Architect is altered, thealtering Architect shall affix tosuch document his seal and thenotation "altered by" followed byhis signature, the date of suchalteration, and a specificdescription of the alteration.ArchitecturePlanningInterior Design217 North Aurora StreetIthaca NY 14850p 607.273.7600 f 607.273.0475DATE:PROJECT:OTHER:DRAWN BY:THESE DOCUMENTS AND ALL IDEAS, ARRANGEMENT,DESIGNS AND PLANS INDICATED THEREON ORPRESENTED THEREBY ARE OWNED AND REMAIN THEPROPERTY OF KENNEDY MECHANICAL INC. AND NO PARTTHEREOF SHALL BE UTILIZED BY ANY PERSON, FIRM, ORCORPORATION FOR ANY PURPOSE WHATSOEVER EXCEPTWITH THE SPECIFIC WRITTEN PERMISSION OF KENNEDYMECHANICAL INC. ALL RIGHTS RESERVED11 COMFORT STREETROCHESTER, NEW YORK 14620585-232-2800Rochester, NY 14625585-313-5819625 Panorama Trail, Building 2, Suite 210Baumer Mechanical Design Services12/10/2014 12:59:07PMM001MECHANICAL -GENERAL NOTES,LEGEND,SCHEDULES7/18/2014ITHACA, NYSTONE QUARRY APARTMENTS, LLCSTONE QUARRY APARTMENTS2012059KAG/JTBVISUAL FIDELITY NOTE: THIS DRAWING SET CONTAINS ELEMENTS TO CONVEYDESIGN INTENT AND TO EASE INTERPRETATION. IF THIS DRAWINGS SET IS RECEIVEDIN MONOCHROME OR GRAYSCALE PLEASE CONTACT KENNEDY MECHANICAL INC. ATTHE NUMBER LISTED TO THE RIGHT FOR A COLOR PRINTED SET.COLOREDSYMBOLS AND LEGENDS:NOTE: ALL SYMBOLS MAY NOT BE USED IN THIS PROJECTREVISION SCHEDULENAME DATEOWNERCHANGES11 SEP 20142 SECTION 5 - WHOLE BUILDING, HOME OR RESIDENT UNIT DELIVERED VENTILATION OR DEDICATED VENTILATIONSYSTEM SHALL MEET OR EXCEED THE RATER-MEASURED VENTILATION RATE TO BE WITHIN 100-120% OF HVAC DESIGN VALUE PER THEFOLLOWING CRITERIA (AS LISTED IN THE HVAC CONTRACTOR CHECKLIST, 2.11):1.RATER-MEASURED VENTILATION RATE IS SCHEDULED TO BE WITHIN 100-120% OF HVAC DESIGN VALUE. THE VENTILATIONSYSTEM MUST BE COMPLIANT WITH ASHRAE 62.2-2010 (FOR REQUIRED VENTILATION QUANTITIES AND SEALING ALL HOLES, GAPS, ANDSEAMS OF DUCTS AND THEIR CONNECTIONS) INCLUDING AS FOLLOWS:A.SUPPLY (SUCH AS AN INTAKE DUCT TO THE RETURN SIDE OF THE HVAC SYSTEM COUPLED WITH A MOTORIZED DAMPERAND CONTROL SYSTEM).B.EXHAUST (SUCH AS A CONTINUOUSLY OPERATING EXHAUST FAN).C.BALANCED (SUCH AS AN ERV OR HRV).2.THE VENTILATION AIR FLOW AND LOCAL EXHAUST AIR FLOWS WILL BE MEASURED BY THE RATER USING A FLOW HOOD,FLOW GRID, ANEMOMETER (IN ACCORDANCE WITH AABC, NEBB OR ASHRAE PROCEDURES), OR SUBSTANTIALLYEQUIVALENT METHOD. ALL SYSTEMS SHOULD BE CONSTRUCTED ACCORDINGLY.SECTION 7 - VENTILATION AIR INLETS AND SOURCESTHE CONTRACTOR SHALL VERIFY LOCATIONS OF ALL CONTAMINATION SOURCE TERMINATIONS AND INSTALL AIR INLETS AT LEAST 10 FT. AWAYFROM ALL CONTAMINATION SOURCE TERMINATIONS AT VERTICAL WALL LOCATIONS AND INSTALL AIR INLETS AT LEAST 3 FT. AWAY FROMDRYER EXHAUSTS AND CONTAMINATION SOURCES EXITING THROUGH THE ROOF UNLESS MORE STRINGENT CRITERIA IS REQUIRED BY CODEOR INDICATED ON THE DESIGN DOCUMENTS.THE CONTRACTOR SHALL INSTALL AIR INLETS AT LEAST 4 FEET ABOVE GRADE OR ROOF DECK FOR THIS PROJECT. THE INLET SHALL HAVERODENT AND INSECT SCREEN WITH A MAXIMUM OF 0.5" MESH SPACING. SCREENS SHALL BE ACCESSIBLE FOR CLEANING.THE VENTILATION AIR MUST COME DIRECTLY FROM OUTDOORS AND NOT FROM ATTICS, CRAWL SPACES, GARAGES OR OTHER DWELLINGS.DUCTWORK, HOODS, LOUVERS AND GRILLES USED FOR INTAKE SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER AND BE SIZESTHAT MAINTAIN THE PROPER FREE AREA FOR AIRFLOW AND LIMITING MOISTURE, SNOW AND DEBRIS CARRYOVER.SECTION 10: COMBUSTION APPLIANCES1.ALL COMBUSTION APPLIANCES SHALL BE MECHANICALLY DRAFTED OR DIRECT VENTED TO THE OUTDOORS.2.FOR ATMOSPHERICALLY VENTED FIREPLACES, THE TOTAL NET RATED EXHAUST FLOW OF THE LARGEST EXHAUST FAN SHALL BELESS THAN OR EQUAL TO 15 CFM PER 100 SQUARE FEET OF OCCUPIABLE SPACE. THE NET-EXHAUST FLOW IS DEFINED AS FLOWTHROUGH AN EXHAUST SYSTEM MINUS THE COMPENSATING OUTDOOR AIRFLOW THROUGH ANY SUPPLY SYSTEM THAT ISINTERLOCKED WITH THE EXHAUST SYSTEM.3.THE CONTRACTOR SHALL COORDINATE ALL UNVENTED COMBUSTION APPLIANCES WITH THE ENERGY STAR RATER. THE RATERIS REQUIRED TO PERFORM TESTS AND THE CONTRACTOR SHALL ASSIST AS REQUIRED.SECTION 11: FILTRATION1.PROVIDE MINIMUM MERV 8 FILTERS IN ALL DUCTED MECHANICAL SYSTEMS. EXHAUST SYSTEMS DUCTED DIRECTLY TO THEOUTSIDE ARE NOT REQUIRED TO BE FILTERED.2.FILTERS SHALL BE LOCATED SUCH THAT ALL RETURN AIR AND OUTSIDE AIR IS FILTERED UPSTREAM OF THE SUPPLY FAN.3.LOCATE FILTERS TO FACILITATE ACCESS AND SERVICE. MAINTAIN CLEARANCES FOR FILTER PULL.4.PROVIDE PRE-FABRICATED FILTER HOUSING WITH GASKETS AND SEALS. HOUSING ACCESS DOOR MUST COMPLETE SEALTO PREVENT BYPASS. SEAL DUCT CONNECTIONS TO PREVENT AIR LEAKAGE. FILTER HOUSING SHALL BE TRION AIR BEARSUPREME OR APPROVED EQUAL. APPROVED EQUALS SHALL BE TESTED IN ACCORDANCE WITH ANSI/ASHRAE 52.2-2007STANDARD TEST PROCEDURES AND BE UL LISTED. CONTRACTOR SHALL SUBMIT FILTERS AND HOUSING FOR REVIEW BYENGINEER.SECTION 3: DUCT INSULATION1.ALL TRUNK DUCTS IN UNCONDITIONED SPACE SHALL BE INSULATED. SEAL ALL SEAMS, GAPS, AND HOLES OF ALL TRUNK DUCT CONNECTIONS BEFOREINSTALLING INSULATION, PREFERABLY WITH MASTIC. INSTALL INSULATION WITHOUT MISALIGNMENT, COMPRESSION, GAPS, OR VOIDS AROUND ALLCONNECTIONS AND EXPOSED DUCTWORK. SEAL DUCTINSULATION TO BOOT TO PREVENT ACCUMULATION OF CONDENSATION.2.INSTALL INSULATED DUCTWORK, BOXES, AND BOOTS IN ALL UNCONDITIONED ATTIC SPACES TO MEET THE PRESCRIPTIVE PATH.INSTALL ALL DUCTS IN UNCONDITIONED SPACES WITHOUT COMPRESSING THE INSULATION. PRESCRIPTIVE PATH: SUPPLYDUCTS IN UNCONDITIONED ATTIC SHALL HAVE GREATER THAN OR EQUAL TO R-8 INSULATION.3.ALL OTHER SUPPLY DUCTS AND ALL RETURN DUCTS IN UNCONDITIONED SPACE SHALL HAVE GREATER THAN OR EQUAL TO R-6INSULATION. INSTALL INSULATED DUCTWORK, BOXES, AND BOOTS IN ALL UNCONDITIONED SPACES. INSTALL ALL DUCTS INUNCONDITIONED SPACES WITHOUT COMPRESSING THE INSULATION.SECTION 2: DUCT QUALITY INSTALLATION1.INSTALL DUCTWORK CONNECTIONS AND ROUTING WITHOUT KINKS OR SHARP BENDS. COORDINATE WITH THE FRAMER, PLUMBER, ANDELECTRICIAN FOR EFFECTIVE DUCT INSTALLATION.2.INSTALL FLEXIBLE DUCTWORK WITHOUT EXCESSIVE COILS OR LOOPS UNLESS NEEDED FOR ACOUSTICAL CONTROL. COORDINATE WITH THEFRAMER, PLUMBER, AND ELECTRICIAN FOR EFFECTIVE DUCT INSTALLATION. BALANCING DAMPERS OR PROPER DUCT SIZING SHALL BEUSED INSTEAD OF LOOPS TO LIMIT FLOW TO DIFFUSERS. WHEN BALANCING DAMPERS ARE USED, THEY SHALL BE LOCATED AT THE TRUNKTO LIMIT NOISE UNLESS THE TRUNK WILL NOT BE ACCESSIBLE WHEN THE BALANCING PROCESS IS CONDUCTED. IN SUCH CASES, OPPOSEDBLADE DAMPERS OR DAMPERS THAT ARE LOCATED IN THE DUCT BOOT ARE PERMITTED.3.FLEXIBLE DUCTWORK SHALL NOT BE INSTALLED IN UNCONDITIONED CAVITIES SMALLER THAN THE OUTER DUCTWORK DIAMETER. FLEXIBLEDUCTWORK SHALL NOT BE INSTALLED IN CONDITIONED CAVITIES SMALLER THAN THE INNER DUCTWORK DIAMETER. INSTALL DUCTS TOPREVENT COMPRESSION OF DUCT OR DUCT INSULATION.4.FLEXIBLE DUCTWORK SHALL BE SUPPORTED AT MANUFACTURER RECOMMENDED INTERVALS BUT AT A DISTANCE LESS THAN OR EQUAL TO5 FT. TO PREVENT SAGGING. INSTALL SUPPORTS AT LEAST ONE INCH WIDE. INSTALL SUPPORTS WITHOUT COMPRESSING THE DUCT ANDTHE DUCT INSULATION.5.BUILDING CAVITIES SHALL NOT BE USED AS SUPPLY OR RETURN DUCTS UNLESS THEY MEET ITEMS 3.2, 3.3, 4.1, AND 4.2 OF THE HVACSYSTEM QUALITY INSTALLATION RATER CHECKLIST. AVOID USING BUILDING CAVITIES AS DUCTS DUE TO THE DIFFICULTY OF PROPERLY AIRSEALING AND INSULATING THEM. IF BUILDING CAVITIES ARE USED, INSTALL INSULATION WITHOUT MISALIGNMENTS, COMPRESSIONS, GAPS,OR VOIDS IN ALL CAVITIES USED FOR DUCTS. IF NON-RIGID INSULATION IS USED, INSTALL A RIGID AIR BARRIER OR OTHER SUPPORTINGMATERIAL TO HOLD INSULATION IN PLACE. SEAL ALL SEAMS, GAPS, AND HOLES OF THE AIR BARRIER WITH CAULK OR FOAM.6.HVAC DUCTS, CAVITIES USED AS DUCTS, AND COMBUSTION AIR INLETS AND OUTLETS MAY PASS PERPENDICULARLY THROUGH EXTERIORWALLS BUT SHALL NOT BE RUN WITHIN EXTERIOR WALLS UNLESS PROVIDED WITH AT LEAST R-6 CONTINUOUS INSULATION ON EXTERIORSIDE OF THE CAVITY, ALONG WITH AN INTERIOR AND EXTERIOR AIR BARRIER WHERE REQUIRED BY THE THERMAL ENCLOSURE SYSTEMCHECKLIST. INSTALL INSULATION WITHOUT MISALIGNMENT, COMPRESSIONS, GAPS, OR VOIDS IN ALL BUILDING CAVITIES WITH DUCTS ORCAVITIES USED AS DUCTS. IF NON-RIGID INSULATION IS USED, INSTALL A RIGID AIR BARRIER OR OTHER SUPPORTING MATERIAL TO HOLDINSULATION IN PLACE. SEAL ALL SEAMS, GAPS, AND HOLES OF THE AIR BARRIER WITH CAULK OR FOAM.7.QUANTITY AND LOCATION OF SUPPLY AND RETURN DUCT TERMINALS SHALL MATCH CONTRACTOR BALANCING REPORT.8.BEDROOMS SHALL BE PRESSURE-BALANCED USING ANY COMBINATION OF TRANSFER GRILLES, JUMPER DUCTS, DEDICATED RETURN DUCTS,AND/OR UNDERCUT DOORS TO EITHER: A) PROVIDE ONE SQUARE INCH OF FREE AREA OPENING PER 1 CFM OF SUPPLY AIR, AS REPORTEDON THE CONTRACTOR-PROVIDED BALANCING REPORT: OR B) ACHIEVE A RATER-MEASURED PRESSURE DIFFERENTIAL LESS THAN OR EQUALTO 3 PA (0.012 IN. W.C.) WITH RESPECT TO THE MAIN BODY OF THE HOUSE WHEN BEDROOM DOORS ARE CLOSED AND THE AIR HANDLER ISOPERATING. FOR PROVIDING FREE AREA, REFER TO THE BALANCING REPORT PROVIDED BY THE HVAC CONTRACTOR FOR THE BEDROOMAIR FLOWS TO SIZE THE TRANSFER GRILLES AND/OR JUMPER DUCTS. INSTALL AND SEAL PROPERLY SIZED TRANSFER GRILLES DURINGFRAMING. BOTH OPENINGS OF THE TRANSFER GRILLE MUST HAVE THE REQUIRED FREE AREA. IF TRANSFER GRILLES ARE NOT USED,INSTALL AND SEAL JUMPER DUCTS DURING FRAMING. BOTH OPENINGS AND DUCTS MUST HAVE THE REQUIRED FREE AREA. FOR ACHIEVINGA RATER-MEASURED PRESSURE DIFFERENTIAL, EPA RECOMMENDS THAT TRANSFER GRILLES, JUMPER DUCTS, OR DEDICATED RETURNS BEINSTALLED. TEST THE PRESSURES OF EACH BEDROOM. FOR HVAC SYSTEM WITH MULTI-SPEED FANS, THE HIGHEST DESIGN FAN SPEEDSHALL BE USED WHEN VERIFYING THIS REQUIREMENT.9.HVAC CONTRACTOR SHALL BE AVAILABLE WHEN RATER IS CONDUCTING THIS TEST.SECTION 9: VENTILATION AND EXHAUST FAN RATINGS1.ALL INTERMITTENT SUPPLY AND EXHAUST FANS SHALL BE RATED BY THE MANUFACTURER TO OPERATE AT LESS THAN OR EQUAL TO 3.0SONES. EXEMPTION: FANS GREATER THAN 400 CFM.2.ALL CONTINUOUSLY OPERATING SUPPLY AND EXHAUST FANS SHALL BE RATED BY THE MANUFACTURER TO OPERATE AT LESS THAN OREQUAL TO 1.0 SONES.3.BATHROOM FANS USED AS PART OF A WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM SHALL BE ENERGY STAR QUALIFIED, UNLESSSPECIFIED FLOW RATE IS GREATER THAN 500 CFM.4.ALL FANS REQUIRED TO BE ENERGY STAR QUALIFIED SHALL HAVE ENERGY STAR LOGO ON THE ASSOCIATED SUBMITTALS. HAND WRITTENNOTATIONS ARE NOT ACCEPTABLE.5.ALL FAN SUBMITTALS SHALL INCLUDE MANUFACTURER'S RATED SONES LEVEL AND SCHEDULED PERFORMANCE VALVES.SECTION 8: LOCAL MECHANICAL EXHAUST1.THE KITCHEN SHALL HAVE AN EXHAUST SYSTEM THAT EXHAUSTS DIRECTLY TO THE OUTDOORS AND SHALL OPERATE CONTINUOUSLY ATA RATE OF GREATER THAN OR EQUAL TO 5 AIR CHANGES PER HOUR BASED ON KITCHEN VOLUME OR OPERATE INTERMITTENTLY AT ARATE GREATER THAN 100 CFM. FANS THAT ARE USED AT A CONTINUOUS RATE SHALL BE RATED FOR CONTINUOUS USE. RECIRCULATINGFANS ARE NOT ACCEPTABLE.2.KITCHEN VOLUME SHALL BE DETERMINED BY DRAWING THE SMALLEST POSSIBLE RECTANGLE ON THE FLOOR PLAN THAT ENCOMPASSESALL CABINETS, PANTRIES, ISLANDS, AND PENINSULAS AND MULTIPLYING BY THE AVERAGE CEILING HEIGHT FOR THIS AREA. CABINETVOLUME SHALL BE INCLUDED IN THE KITCHEN VOLUME CALCULATION.3.EACH BATHROOM SHALL HAVE AN EXHAUST SYSTEM THAT EXHAUSTS DIRECTLY TO THE OUTDOORS AND SHALL OPERATE CONTINUOUSLYAT A RATE OF GREATER THAN OR EQUAL 20 CFM OR OPERATE INTERMITTENTLY AT A RATE GREATER THAN 50 CFM. FANS THAT ARE USEDAT A CONTINUOUS RATE SHALL BE RATED FOR CONTINUOUS USE.4.AN INTERMITTENT EXHAUST SYSTEM, WHERE PROVIDED, SHALL BE DESIGNED TO OPERATE AS NEEDED BY THE OCCUPANT. CONTROLDEVICES SHALL NOT IMPEDE OCCUPANT CONTROL IN INTERMITTENT SYSTEMS.5.ALL FANS THAT SHARE A COMMON EXHAUST DUCT SHALL BE EQUIPPED WITH A BACK-DRAFT DAMPER. REMOVE ALL PACKING TAPE FROMBACK-DRAFT DAMPERS UPON INSTALLATION.6.COMMON EXHAUST DUCTS SHALL NOT BE SHARED BY FANS IN SEPARATE DWELLINGS.7.CLOTHES DRYERS SHALL BE VENTED DIRECTLY TO THE OUTDOORS, EXCEPT FOR VENT-LESS DRYERS EQUIPPED WITH A CONDENSATEDRAIN. VENT CLOTHES DRYERS IN ACCORDANCE WITH THE MECHANICAL CODE OF NEW YORK STATE.8.DO NOT USE DEVICES THAT REMOVE LINT AND/OR BRING THE HEAT BACK INTO THE SPACE.9.DO NOT EXHAUST DRYERS WITHIN 10 FEET OF AN AIR COOLED CONDENSING UNIT.10.ALL EXHAUST FANS SHALL BE DIRECTLY DUCTED TO THE EXTERIOR WITH LITTLE OR NO RESTRICTION.11.SEAL ALL SEAMS, GAPS, HOLES, AND CONNECTIONS TO THE EXTERIOR OF ALL EXHAUST DUCTS WITH MASTIC. IT IS THE CONTRACTOR'SRESPONSIBILITY TO ENSURE A PROPER QUALITY INSTALLATION. THE EXHAUST DUCTWORK WILL BE TESTED FOR LEAKS AT THE END OFTHE PROJECT AND THE CONTRACTOR IS RESPONSIBLE FOR THE RESULTS OF THE TEST.12.CORROSION-PROOF RODENT/BIRD SCREENS INSTALLED AT ALL OPENINGS THAT CANNOT BE FULLY SEALED 3.2OOO(EXCEPTION: DRYER VENTS).SECTION 6 - THERMOSTAT AND HVAC UNIT CONTROLS:1.THERMOSTAT, AIR FLOW IS PRODUCED WHEN THE CENTRAL HVAC INDOOR FURNACE OR FAN COIL EVAPORATOR FAN IS ENERGIZED.THIS IS ACCOMPLISHED BY SETTING THE THERMOSTAT TO "FAN" SELECTING THE COOLING OR HEATING MODE WILL INDEX THE COOLINGOR HEATING PORTIONS OF THE SYSTEM TO PROVIDE EITHER COOLED OR HEATED AIR TO MEET THE ROOM OR UNIT THERMOSTAT SETPOINT.THE RATER, AS PART OF THE TESTING WILL TURN THE SYSTEM ON TO COOL AND CHANGE THE SET POINT TEMPERATURE TO 3 DEGREESF BELOW THE AMBIENT TEMPERATURE. THE RATER WILL THEN RETURN THE THERMOSTAT TO THE ORIGINAL SETTING. THE RATER WILLWAIT FOR A PERIOD OF TIME AS RECOMMENDED BY THE UNIT MANUFACTURER OR WAIT FOR THE SYSTEM PREPROGRAMMED CYCLEBETWEEN COOLING AND HEATING MODE AND SET THE SYSTEM ON TO HEATING AND CHANGE THE SET POINT TO 3 DEGREES F ABOVETHE AMBIENT. THE RATER WILL THEN RETURN THE THERMOSTAT TO THE ORIGINAL SETTING.THE RATER WILL VERIFY THAT THE HEATING AND COOLING SYSTEMS ARE WORKING PROPERLY BY MEASURING THE OUTPUTTEMPERATURE OF THE SYSTEMS DURING THE APPROPRIATE CYCLES.IN CASES WHERE THE CONDENSER UNIT OR OUTDOOR HEAT PUMP SECTION CAN ABSOLUTELY ONLY BE INSTALLED AFTER THE TIME OFINSPECTION BY THE RATER, THE RATER IS EXEMPT FROM VERIFYING THE COOLING MODE OR HEATING IF IT IS A HEAT PUMP UNIT.2.ENERGY RECOVERY DEVICES OR CONTINUOUSLY OPERATING FANS, OTHER THAN BATHROOM OR TOILET ROOM FANS:IT IS IMPORTANT FOR HVAC CONTRACTORS AND ELECTRICIANS TO LOCATE THE OVERRIDE CONTROLS FOR CONTINUOUSLY OPERATINGVENTILATION AND EXHAUST FANS IN A LOCATION EASILY ACCESSIBLE TO THE OCCUPANT. IT IS ALSO IMPORTANT TO PROPERLY LABELTHESE CONTROLS. IF CONTROLS ARE NOT PROPERLY LABELED, FANS MAY BE MISTAKENLY TURNED OFF.OVERRIDE CONTROL LOCATION RECOMMENDATIONS:LOCATION OF THE LABELED CONTROL NEAR THE THERMOSTAT CREATES A TYPE OF CONTROL CENTER FOR THE OCCUPANT. THISALLOWS ACCESS THE MAJORITY OF THE HVAC SYSTEM CONTROLS IN ONE LOCATION. THIS SETUP IS IDEAL FOR VENTILATION SYSTEMS,SUCH AS ERV'S and HRV'S THAT MAY BE LOCATED IN INACCESSIBLE PLACES.LOCATING A SWITCH OR SWITCHING BREAKER AT AN ELECTRICAL PANEL WITH A LABEL WOULD BE SUITABLE WHERE THERE AREMULTIPLE CONTINUOUSLY RUNNING EXHAUST FANS.BATHROOM OR TOILET EXHAUST FANS MAY BE SPECIFIED FOR THIS PROJECT TO HAVE INTERNAL OVERRIDE SYSTEMS, EITHER ON THEELECTRICAL SWITCH PLATE OR DEFINED IN THE MANUFACTURER'S MANUAL. THESE EXHAUST FANS MEET THE REQUIREMENTS AS LONGAS THE OVERRIDE IS ACCESSIBLE AND THE DOCUMENTATION IS REVIEWED BY THE RATER.THE SWITCHES OR CONTROL DEVICES SHOULD CLEARLY, PERMANENTLY AND PROFESSIONALLY LABELED FOR THE EQUIPMENT SERVEDAND THE FUNCTIONS. IF REQUIRED ON PLANS OR ELSEWHERE IN THE SPECIFICATIONS THERE SHALL ALSO BE A PILOT LIGHT TOINDICATE EQUIPMENT IS ENERGIZED.3.CONTINUOUSLY OPERATING VENTILATION AND EXHAUST FANS MUST INCLUDE READILY ACCESSIBLE OVERRIDE CONTROLS.4.FUNCTION OF VENTILATION CONTROLS IS OBVIOUS (E.G. BATHROOM EXHAUST FAN) OR, IF NOT, CONTROLS HAVE BEEN LABELED.SECTION 1: REVIEW OF ENERGY STAR V3 REV 07 HVAC SYSTEM QUALITY INSTALLATION CONTRACTOR CHECKLIST1.COMPLETE AND COLLECT FOR RECORDS HVAC SYSTEM QUALITY INSTALLATION CONTRACTOR CHECKLIST IN ITS ENTIRETY, ALONG WITH DOCUMENTATION ON VENTILATIONSYSTEM, FULL LOAD CALCULATIONS, AHRI CERTIFICATE AND BALANCING REPORT. IT IS THE CONTRACTOR'S RESPONSIBILITY TO COMPLETE THE CHECKLISTS IN THEIR ENTIRETYAS THE RATER WILL BE RESPONSIBLE TO VERIFY INPUTS SUCH AS DESIGN TEMPS, U VALUES, # OF OCCUPANTS, SQUARE FOOTAGE, ORIENTATION, ETC. IT IS THE CONTRACTOR'SEXCLUSIVE RESPONSIBILITY TO ENSURE THE SYSTEM DESIGN AND INSTALLATION COMPLY WITH THE CONTRACTOR CHECKLIST SPECIFICATIONS. THE RATER WILL USE THEENERGY STAR V3 HVAC QI RATER CHECKLIST TO VERIFY THE INPUTS FROM THE HVAC CONTRACTOR CHECKLIST SUCH AS EQUIPMENT MODEL NUMBERS,EFFICIENCIES,CAPACITIES; REFRIGERANT CHARGE TEST METHOD; STATIC PRESSURES; VENTILATION; TESTING & BALANCING, ETC.2.REVIEW THE FOLLOWING PARAMETERS RELATED TO SYSTEM COOLING DESIGN, SELECTION, AND INSTALLATION FROM HVACCONTRACTOR CHECKLIST:A.OUTDOOR DESIGN TEMPERATURES ARE EQUAL TO 1% AND 99% ACCA MANUAL J DESIGN TEMPERATURES FORCONTRACTOR-DESIGNATED DESIGN LOCATION.B.HOME ORIENTATION MATCHES ORIENTATION OF RATED HOME.C. NUMBER OF OCCUPANTS EQUALS NUMBER OF OCCUPANTS IN RATED HOME. THE NUMBER OF OCCUPANTS AMONG ALL HVACSYSTEMS IN THE HOME SHALL BE EQUAL TO THE NUMBER OF RESNET-DEFINED BEDROOMS PLUS ONE. OCCUPANTS LISTEDFOR SYSTEMS FOR WHICH THE HEADER OF THE CONTRACTOR CHECKLIST INDICATES THAT IT IS DESIGNED TO HANDLETEMPORARY OCCUPANT LOADS SHALL BE PERMITTED TO EXCEED THIS LIMIT.D.CONDITIONED FLOOR AREA IS WITHIN PLUS OR MINUS 10% OF CONDITIONED FLOOR AREA OF RATED HOME.E. WINDOW AREA IS WITHIN PLUS OR MINUS 10% OF CALCULATED WINDOW AREA OF RATED HOME.F.PREDOMINANT WINDOW SHGC IS WITHIN 0.1 OF PREDOMINANT VALUE IN RATED HOME. PREDOMINANT IS DEFINED AS THESHGC VALUE USED IN THE GREATEST AMOUNT OF WINDOW AREA IN THE HOME.G.LISTED LATENT COOLING CAPACITY EXCEEDS DESIGN LATENT HEAT GAIN.H.LISTED SENSIBLE COOLING CAPACITY EXCEEDS DESIGN SENSIBLE HEAT GAIN.I.LISTED TOTAL COOLING CAPACITY IS 95-115% (OR 95-125% FOR HEAT PUMPS IN CLIMATE ZONES 4-8) OF DESIGN TOTAL HEATGAIN, OR HEAT NOMINAL SIZE. FOR COOLING SYSTEMS THE NEXT LARGEST NOMINAL PIECE OF EQUIPMENT MAY BE USED THATIS AVAILABLE TO SATISFY THE LATENT AND SENSIBLE REQUIREMENTS. SINGLE-SPEED SYSTEMS GENERALLY HAVE OEMNOMINAL SIZE INCREMENTS OF 1/2 TON. MULTI-SPEED OR MULTI-STAGE EQUIPMENT MAY HAVE OEM NOMINAL SIZEINCREMENTS OF ONE TON. THEREFORE, THE USE OF THESE ADVANCED SYSTEM TYPES CAN PROVIDE EXTRA FLEXIBILITY TOMEET THE EQUIPMENT SIZING REQUIREMENTS.J.HVAC MANUFACTURER AND MODEL NUMBERS ON INSTALLED EQUIPMENT, CONTRACTOR CHECKLIST, AND AHRI CERTIFICATE OROEM CATALOG DATA ALL MATCH. IN CASES WHERE THE CONDENSER UNIT IS INSTALLED AFTER THE TIME OF INSPECTION BYTHE RATER, THE HVAC MANUFACTURER AND MODEL NUMBERS ON INSTALLED EQUIPMENT CAN BE DOCUMENTED THROUGH THEUSE OF PHOTOGRAPHS PROVIDED BY THE HVAC CONTRACTOR AFTER INSTALLATION IS COMPLETE.K.USING REPORTED LIQUID LINE OR SUCTION LINE PRESSURE, CORRESPONDING TEMPERATURE (AS DETERMINED USINGPRESSURE/TEMPERATURE CHART FOR REFRIGERANT TYPE) MATCHES REPORTED CONDENSER OR EVAPORATOR SATURATIONTEMPERATURE (PLUS OR MINUS 3 DEGREES). IF CONTRACTOR HAS INDICATED THAT AN OEM TEST PROCEDURE HAS BEENUSED IN PLACE OF A SUB-COOLING OR SUPER-HEAT PROCESS AND DOCUMENTATION HAS BEEN ATTACHED THAT DEFINES THISPROCEDURE, THEN THE BOX FOR "N/A" SHALL BE CHECKED FOR THIS ITEM.L.CALCULATED SUB-COOLING OR SUPERHEAT VALUE EQUALS REPORTED TARGET SUB-COOLING OR SUPERHEAT TEMPERATURE.IF CONTRACTOR HAS INDICATED THAT AN OEM TEST PROCEDURE HAS BEEN USED IN PLACE OF A SUB-COOLING ORSUPER-HEAT PROCESS AND DOCUMENTATION HAS BEEN ATTACHED THAT DEFINES THIS PROCEDURE, THEN THE BOX FOR "N/A"SHALL BE CHECKED FOR THIS ITEM.3. RATER-VERIFIED SUPPLY AND RETURN DUCT STATIC PRESSURE SHALL BE LESS THAN 110% OF CONTRACTOR RECORD VALUES.4.SUBMIT CONTRACTOR PREPARED REPORT INDICATING THE ROOM NAME AND DESIGN AIRFLOW FOR EACH SUPPLY AND RETURNREGISTER TO RATER FOR RECORD. IN ADDITION, FINAL BALANCING REPORT INDICATING ROOM AIRFLOWS MEASURED ANDDOCUMENTED ON BALANCING REPORT THROUGH ONE OF THE FOLLOWING OPTIONS: 1. MEASURED AND DOCUMENTED BY THECONTRACTOR. 2. MEASURED BY RATER USING SECTION 804.2 OF THE MORTGAGE INDUSTRY NATIONAL HERS STANDARD, DOCUMENTED BYRATER, AND VERIFIED BY RATER TO BE WITHIN THE GREATER OF +/-20% OR 25 CFM OF DESIGN AIRFLOW.5.HVAC CONTRACTOR HOLDS CREDENTIALS NECESSARY TO COMPLETE THE HVAC SYSTEM QI CONTRACTOR CHECKLIST. THE RATER MUSTCONFIRM THE CONTRACTOR HOLDS THE CREDENTIALS..1.SECTION 4: DUCT LEAKAGEDUCT LEAKAGE SHALL MEET OR EXCEED THE FOLLOWING CRITERIA:1.TOTAL RATER-MEASURED DUCT LEAKAGE = 8 CFM25 (CFM25 = CFM @ 25 PASCALS AIR PRESSURE) PER 100 SQ. FT. OF CONDITIONED FLOOR AREA (CFA).A. SEAL ALL SEAMS, GAPS, AND HOLES OF ALL TRUNK DUCT CONNECTIONS BEFORE INSTALLING INSULATION, PREFERABLY WITHMASTIC.B.INSTALL INSULATION WITHOUT MISALIGNMENTS, COMPRESSIONS, GAPS, OR VOIDS AROUND ALL CONNECTIONS AND EXPOSED DUCTWORKC. SEAL DUCT INSULATION IN PLACE.D.EPA RECOMMENDS TESTING DUCTS ONLY AFTER COMPLETING A VISUAL INSPECTION OF PROPER DUCT SEALING.2. RATER-MEASURED DUCT LEAKAGE TO OUTDOORS = 4 CFM25 PER 100 SQ. FT. OF CONDITIONED FLOOR AREA.A.SEAL ALL SEAMS, GAPS, AND HOLES OF ALL TRUNK DUCT CONNECTIONS BEFORE INSTALLING INSULATION. MASTIC IS RECOMMENDEDFOR SEALINGB.INSTALL INSULATION WITHOUT MISALIGNMENT, COMPRESSION, GAPS, OR VOIDS AROUND ALL CONNECTIONS AND EXPOSED DUCTWORK.C.SEAL DUCT INSULATION IN PLACE.D.EPA RECOMMENDS TESTING DUCTS ONLY AFTER COMPLETING A VISUAL INSPECTION OF PROPER DUCT SEALING.3.ADDITIONAL TESTING, QUALIFICATION AND INSTALLATION GUIDELINES TO MEET FOR LEAKAGE CRITERIAADUCT LEAKAGE SHALL BE DETERMINED AND DOCUMENTED BY A RATER USING A RESNET-APPROVED TESTING PROTOCOL DURINGROUGH-IN (≤ 4 CFM25 PER 100 SQ. FT. OF CFA WITH AIR HANDLER AND ALL DUCTWORK, BUILDING CAVITIES USED AS DUCTWORK,& DUCT BOOTS INSTALLED. IN ADDITION, ALL DUCT BOOTS SEALED TO FINISHED SURFACE, RATER-VERIFIED AT FINAL) ANDAFTER ALL COMPONENTS OF THE SYSTEM HAVE BEEN INSTALLED (E.G., AIR HANDLER AND REGISTER GRILLES). LEAKAGE LIMITSSHALL BE ASSESSED ON A PER-SYSTEM BASIS, RATHER THAN PER RESIDENT UNIT, WHERE COMMON SYSTEMS ARE USED.TESTING OF DUCT LEAKAGE TO THE OUTSIDE CAN BE WAIVED, HOWEVER THIS MUST BE CONFIRMED BY THE RATER FOR EACHPROJECT IF ALL DUCTS AND AIR HANDLING EQUIPMENT ARE LOCATED WITHIN THE HOME'S AIR AND THERMAL BARRIERS, ANDENVELOPE LEAKAGE HAS BEEN TESTED TO BE LESS THAN OR EQUAL TO HALF OF THE PRESCRIPTIVE PATH INFILTRATION LIMITFOR THE CLIMATE ZONE WHERE THE HOME IS TO BE BUILT.B.FOR ALL HOMES OR UNITS THAT SERVE LESS THAN 1,200 SQ. FT. OF CONDITIONED FLOOR AREA (CFA), TOTAL MEASURED DUCTLEAKAGE SHALL BE = 8 CFM25 PER 100 SQ. FT. OF CFA AND MEASURED DUCT LEAKAGE TO OUTDOORS SHALL BE = 5 CFM25 PER100 SQ. FT. OF CFA.C.IF TOTAL DUCT LEAKAGE IS = 4 CFM25 PER 100 SQ. FT. OF CONDITIONED FLOOR AREA, OR = 5 CFM25 PER 100 SQ. FT. OFCONDITIONED FLOOR AREA FOR HOMES OR UNITS THAT HAVE LESS THAN 1,200 SQ. FT. OF CONDITIONED FLOOR AREA, THENLEAKAGE TO OUTDOORS NEED NOT BE TESTED.D.WHERE DUCTWORK, DUCT BOOTS, PLENUMS AND OTHER DEVICES PENETRATE ANY BUILDING ELEMENT THE OPENINGS SHALL BECUT NEATLY AND CLOSE TO THE ACTUAL SIZE OF THE DUCT, BOOT OR PLENUM TO MINIMIZE GAPS AND THE EXTENT OF SEALANTMATERIAL. WORK SHALL BE ACCOMPLISHED IN A NEAT AND WORKMAN LIKE MANNER. DUCT BOOTS SEALED TO FLOOR, WALL,OR CEILING USING CAULK, FOAM, MASTIC TAPE, OR MASTIC PASTE. THIS SHALL BE COORDINATED BY ALL APPROPRIATE TRADES.POOR INSTALLATIONS WITH TOO MUCH TOLERANCE CAUSING EXCESSIVE SEALANT MATERIAL SHALL BE IMMEDIATELY BROUGHTTO THE ATTENTION OF THE GENERAL CONTRACTOR FOR CORRECTIVE ACTION TO BE TAKEN.E.DUCT CONNECTIONS, PARTIAL AND FULL CASED SECTIONS OF THE FAN COIL UNIT-FURNACE-HEAT PUMP UNIT, OR AIR HANDLINGUNIT AND SERVICE DOORS OR ACCESS PANELS SHALL BE SEALED WITH PERMANENT MASTIC, HIGH QUALITY NON PERMEABLEFOAM, NEOPRENE, CORK GASKET OR HIGH QUALITY AIR TIGHT SEALING CAULK AT FIXED POINTS AND / OR UL RATED TAPE WHENACCESS IS REQUIRED. WHERE TAPE IS UTILIZED A SUFFICIENT AMOUNT OF ROLLS OF TAPE SHALL BE PROVIDED TO BE KEPT ATTHE PROJECT AND TURNED OVER TO THE BUILDING OWNER TO RESEAL THE SERVICE POINTS AFTER CUTTING OR REMOVINGTHE TAPE PROVIDED TO MEET THE LEAKAGE TESTS.ENERGY STAR QUALIFIED HOMES, REQUIREMENTS:ENERGY STAR QUALIFIED HOMES, REQUIREMENTS (CON'T)ENERGY STAR QUALIFIED HOMES, REQUIREMENTS (CON'T)CONTRACTORS SHALL BE ACCA-QUALIFIED OR H-QUITO THROUGH ADVANCED ENERGY OR NYSERDA AND COMPLY WITH ENERGY STAR QUALIFIED HOMES, VERSION3 (REV. 7), HVAC SYSTEM QUALITY INSTALLATION RATER CHECKLIST AND REQUIREMENTS NOTED BELOW.ABCDEFGABCDEFG1234567891012345678910WARNING: It is a violation ofNew York State Law for anyperson, unless acting under thedirection of a licensed Architect,to alter this document in any way.If a document bearing the seal ofan Architect is altered, thealtering Architect shall affix tosuch document his seal and thenotation "altered by" followed byhis signature, the date of suchalteration, and a specificdescription of the alteration.ArchitecturePlanningInterior Design217 North Aurora StreetIthaca NY 14850p 607.273.7600 f 607.273.0475DATE:PROJECT:OTHER:DRAWN BY:THESE DOCUMENTS AND ALL IDEAS, ARRANGEMENT,DESIGNS AND PLANS INDICATED THEREON ORPRESENTED THEREBY ARE OWNED AND REMAIN THEPROPERTY OF KENNEDY MECHANICAL INC. AND NO PARTTHEREOF SHALL BE UTILIZED BY ANY PERSON, FIRM, ORCORPORATION FOR ANY PURPOSE WHATSOEVER EXCEPTWITH THE SPECIFIC WRITTEN PERMISSION OF KENNEDYMECHANICAL INC. ALL RIGHTS RESERVED11 COMFORT STREETROCHESTER, NEW YORK 14620585-232-2800Rochester, NY 14625585-313-5819625 Panorama Trail, Building 2, Suite 210Baumer Mechanical Design Services12/10/2014 12:59:12PMM002ENERGY STARQUALIFIEDHOMESREQUIREMENTS7/18/2014ITHACA, NYSTONE QUARRY APARTMENTS, LLCSTONE QUARRY APARTMENTS2012059KAG/JTBREVISION SCHEDULENAME DATE REF.WDREF.REF.REF.REF.REF.DWDWDWDWREF. REF.TT12T: 7'-10"B: 7'-2"18"x8"12"x8"6"ø6"ø6"øT: 7'-9"B: 7'-3"T: 7'-9"B: 7'-3"6"ø6"ø7"ø6"ø7"ø6"ø4"ø4"ø4"ø6"ø4"ø7"ø6"ø6"ø5"ø18"x8"6"ø5"ø6"ø6"ø6"ø18"x8"6"ø6"ø5"ø6"ø5"ø6"ø6"ø18"x8"16"x8"5"ø6"ø6"ø18"x8" 16"x8"5"ø6"ø6"ø6"ø6"øT: 7'-9"B: 7'-3"T: 7'-10"B: 7'-2"T: 7'-9"B: 7'-3"5"øT: 8'-10"B: 8'-4"T: 8'-10"B: 8'-4"T: 7'-9"B: 7'-3"T: 7'-10"B: 7'-2"T: 7'-9"B: 7'-3"T: 7'-9"B: 7'-4"T: 8'-11"B: 8'-4"T: 7'-9"B: 7'-3"T: 8'-10"B: 8'-4"T: 7'-10"B: 7'-2"T: 7'-9"B: 7'-3"T: 7'-9"B: 7'-4"T: 8'-11"B: 8'-4"T: 7'-9"B: 7'-3"T: 8'-10"B: 8'-4"T: 7'-10"B: 7'-2"T: 7'-9"B: 7'-3"T: 8'-9"B: 8'-5"T: 7'-10"B: 7'-2"T: 7'-9"B: 7'-3"T: 7'-9"B: 7'-3"T: 8'-9"B: 8'-5"T: 7'-10"B: 7'-2"T: 7'-10"B: 7'-2"T: 7'-9"B: 7'-4"T: 7'-9"B: 7'-3"T: 8'-10"B: 8'-4"T: 7'-9"B: 7'-3"T: 7'-8"B: 7'-4"T: 7'-10"B: 7'-3"16x12TRANSFER6" A.F.F.16x12TRANSFER6" A.F.F.16x12TRANSFER6" A.F.F.16x12TRANSFER6" A.F.F.16x12TRANSFER6" A.F.F.16x12TRANSFER6" A.F.F.7"ø12x612512x612512x611510x45012x612510x47512x612510x47512x612512x612510x45012x612512x612512x612512x612512x612510x45010x45012x612512x612512x612510x475T: 8'-3"B: 7'-9"6"øT: 8'-11"B: 8'-4"7"ø10"x8"4"ø4"ø4"ø4"ø4"ø4"ø12x610016x12TRANSFER6" A.F.F.10"x8"16"x8"10"x8"8"ø8"øT: 7'-10"B: 7'-2"T: 7'-10"B: 7'-2"T: 6'-10"B: 6'-2"T: 7'-10"B: 7'-2"T: 7'-9"B: 7'-3"T: 7'-10"B: 7'-2"T: 7'-10"B: 7'-2"20"x8"20"x8"8"x8"T: 7'-10"B: 7'-2"LOUVER L-118x8LOUVER L-218x8STACKED 4" DRYEREXHAUST VENTS (6)SEE DETAIL M300FURN-AFURN-BEF-1EF-2FURN-AEF-1FURN-AFURN-AFURN-AEF-1EF-2EF-3EF-1EF-1DSS-AEF-316"x8"T: 7'-10"B: 7'-2"16"x8"16"x8"5"ø16"x8"6"ø6"ø12"x8"12"x8"10x820010x4506"ø12x610010x550EF-212x82008x83008"20024"x8"24"x8"20"x8"T: 7'-10"B: 7'-2"10"x8"14x625014x6250T: 7'-10"B: 7'-2"24"x8"24"x8"5"ø14x625014x625014x625016x8016"x8"T: 7'-10"B: 7'-2"T: 7'-10"B: 7'-2"12x612510x4754"øT: 7'-9"B: 7'-5"11111222223333344444444444455555555555554666646444466337CUH-S1CUH-L1CUH-S18899996"Ø DUCT UPTO FLOOR ABOVE5"Ø DUCT UPTO FLOOR ABOVE6"Ø DUCT UPTO FLOOR ABOVE6"Ø DUCT UPTO FLOOR ABOVE6"Ø DUCT UPTO FLOOR ABOVEOA INTAKE WALL CAP112X61006"ø5"ø7"ø6"ø6"ø18"x8"4"ø6"ø5"ø13"x20"6X1210010x45010x475EF-2ACC-1ACC-116"x8"10x45010x4756"ø5"ø7"ø6"ø6"ø18"x8"4"ø6"ø5"ø10x610010x95010x1075EF-216"x8"10x125010x107513"x20"12x27100ABCDEFGABCDEFG1234567891012345678910WARNING: It is a violation ofNew York State Law for anyperson, unless acting under thedirection of a licensed Architect,to alter this document in any way.If a document bearing the seal ofan Architect is altered, thealtering Architect shall affix tosuch document his seal and thenotation "altered by" followed byhis signature, the date of suchalteration, and a specificdescription of the alteration.ArchitecturePlanningInterior Design217 North Aurora StreetIthaca NY 14850p 607.273.7600 f 607.273.0475DATE:PROJECT:OTHER:DRAWN BY:THESE DOCUMENTS AND ALL IDEAS, ARRANGEMENT,DESIGNS AND PLANS INDICATED THEREON ORPRESENTED THEREBY ARE OWNED AND REMAIN THEPROPERTY OF KENNEDY MECHANICAL INC. AND NO PARTTHEREOF SHALL BE UTILIZED BY ANY PERSON, FIRM, ORCORPORATION FOR ANY PURPOSE WHATSOEVER EXCEPTWITH THE SPECIFIC WRITTEN PERMISSION OF KENNEDYMECHANICAL INC. ALL RIGHTS RESERVED11 COMFORT STREETROCHESTER, NEW YORK 14620585-232-2800Rochester, NY 14625585-313-5819625 Panorama Trail, Building 2, Suite 210Baumer Mechanical Design Services12/10/2014 12:59:41PMM100APARTMENTBLDG./TH FIRSTFLOOR PLANS -HVAC7/18/2014ITHACA, NYSTONE QUARRY APARTMENTS, LLCSTONE QUARRY APARTMENTS2012059KAG/JTB 1/8" = 1'-0"1APARTMENT BLDG. FIRST FLOOR PLAN - HVAC 1/8" = 1'-0"2TYPICAL TOWNHOME FIRST FLOOR PLAN - HVACREVISION SCHEDULENAME DATE15 AUG 2014#FIRST FLOOR HVAC PLAN DRAWING NOTES1 PROVIDE SHEET METAL PLENUM SAME SIZE AS EVAPORATOR CONNECTION.2 FURNACE ACCESS AREA. KEEP FREE OF OBSTRUCTION.3 7" EXHAUST DUCT DOWN TO RANGE HOOD.PROVIDE A DUCT TRANSITION AS REQURIED TO MAKE THE FINAL CONNECTION TO THE RANGE HOOD. RANGE HOOD IS PROVIDED BYOTHERS.4 PROVIDE WALL CAP OUTLET. THE WALL CAP OUTLET SHALL BE A HOODED TYPE SELECTED FROM THE SIDING MANUFACTURERS STANDARDS. THE HOOD SHALL BE VINYLCONSTRCTION WITH A BACKDRAFT DAMPER. COLOR SHALL BE SELECTED BY THE ARCHITECT. COORDINATE EXACT LOCATION WITH THE ARCHITECT ELEVATIONS.5 DUCTWORK SHALL BE INSTALLED IN THE SOFFITS. TEST THE DUCTWORK BEFORE THE SOFFITS ARE CLOSED UP. COORDINATE WITH APPLICABLE TRADES.6 PROVIDE 7" KITCHEN EXHAUST DUCT THRU SIDEWALL ON THE 1ST/2ND FLOORS.7 LOUVER L-1 TO OPEN WHEN FAN ON F-2 RUNS OCCUPIED MODE (24 VOLT CIRCUIT).8 13x20 SUPPLY DUCT DOWN FROM FURNACE PLENUM ON SECOND FLOOR9 DUCTWORK LOCATED IN AN UNCONDITIONED SPACE SHALL BE INSULATED. REF.REF.REF.REF.REF.DWDWDWDWREF.DWREF.DWDW7"ø16x12TRANSFER6" A.F.F.16x12TRANSFER6'-10" A.F.F.16x12TRANSFER6" A.F.F.16x12TRANSFER6'-10" A.F.F.6"øT: 7'-9"B: 7'-3"6"øT: 7'-9"B: 7'-3"T: 7'-9"B: 7'-3"T: 8'-3"B: 7'-9"6"ø7"ø6"øT: 7'-9"B: 7'-3"T: 8'-11"B: 8'-4"10x45012x612516x12TRANSFER6" A.F.F.16x12TRANSFER6" A.F.F.6"øT: 8'-10"B: 8'-4"16x12TRANSFER6" A.F.F.16x12TRANSFER6" A.F.F.16x12TRANSFER6" A.F.F.6"ø18"x8"T: 7'-10"B: 7'-2"T: 8'-10"B: 8'-4"16x12TRANSFER6" A.F.F.16x12TRANSFER6" A.F.F.6"ø18"x8"6"ø16x12TRANSFER6" A.F.F.6"øT: 8'-10"B: 8'-4"7"ø6"øT: 8'-10"B: 8'-4"NO WALLTRANSFER LOCATIONUNDERCUTTHE DOOR?18"x8"6"ø6"ø6"ø6"ø5"ø6"ø18"x8" 16"x8"6"ø5"ø6"ø6"ø6"ø5"ø7"ø7"ø18"x8"16"x8"5"ø6"ø6"ø6"ø6"ø6"ø18"x8" 16"x8"5"ø6"ø6"ø6"ø18"x8"6"ø5"ø5"ø7"ø5"ø6"ø7"ø6"ø12x612512x612512x612510x45012x612510x45012x612510x45010x45012x612510x45012x612512x612512x612512x612510x45012x612512x612512x612510x45012x612512x612510x47512x612512x612510x47512x612512x612510x45012x612512x612512x6125T: 7'-10"B: 7'-2"T: 7'-9"B: 7'-3"T: 7'-9"B: 7'-3"T: 7'-9"B: 7'-3"T: 8'-10"B: 8'-3"T: 8'-10"B: 8'-3"T: 7'-10"B: 7'-2"T: 7'-9"B: 7'-3"T: 7'-9"B: 7'-4"T: 7'-10"B: 7'-2"T: 8'-11"B: 8'-4"T: 7'-10"B: 7'-2"T: 7'-10"B: 7'-2"T: 7'-9"B: 7'-3"T: 7'-10"B: 7'-2"T: 7'-9"B: 7'-3"T: 7'-9"B: 7'-3"T: 7'-10"B: 7'-2"T: 7'-10"B: 7'-2"T: 7'-9"B: 7'-3"T: 7'-9"B: 7'-3"T: 7'-9"B: 7'-3"T: 7'-10"B: 7'-2"T: 7'-9"B: 7'-4"T: 7'-10"B: 7'-2"T: 7'-9"B: 7'-3"T: 7'-9"B: 7'-4"T: 7'-9"B: 7'-3"T: 7'-10"B: 7'-3"T: 7'-9"B: 7'-4"T: 7'-9"B: 7'-4"NEW SOFFITNEW SOFFITNEW SOFFITNEW SOFFITNEW SOFFITNEW SOFFITNEW SOFFITNEW SOFFITNEW SOFFITT: 8'-11"B: 8'-4"T: 8'-11"B: 8'-4"T: 7'-10"B: 7'-3"T: 7'-9"B: 7'-3"6"ø6"ø6"øT: 7'-9"B: 7'-3"DSS-AEF-1FURN-AFURN-AEF-1FURN-AEF-1EF-1FURN-AEF-1FURN-AEF-1FURN-AEF-111111122222223333333444444444455555555555556666677EF-288OA INTAKE WALL CAPT: 7'-9"B: 7'-5"4"ø4"ø41FURN-A12x41204X105012x410012x410016X12TRANSFER6'-10" A.F.F.16X12TRANSFER6'-10" A.F.F.20X20TRANSFER6" A.F.F.EF-16"øFURN-A12x512016X12TRANSFER6'-10" A.F.F.20X20TRANSFER6" A.F.F.12x155016X12TRANSFER6'-10" A.F.F.12x410012x4100EF-1ABCDEFGABCDEFG1234567891012345678910WARNING: It is a violation ofNew York State Law for anyperson, unless acting under thedirection of a licensed Architect,to alter this document in any way.If a document bearing the seal ofan Architect is altered, thealtering Architect shall affix tosuch document his seal and thenotation "altered by" followed byhis signature, the date of suchalteration, and a specificdescription of the alteration.ArchitecturePlanningInterior Design217 North Aurora StreetIthaca NY 14850p 607.273.7600 f 607.273.0475DATE:PROJECT:OTHER:DRAWN BY:THESE DOCUMENTS AND ALL IDEAS, ARRANGEMENT,DESIGNS AND PLANS INDICATED THEREON ORPRESENTED THEREBY ARE OWNED AND REMAIN THEPROPERTY OF KENNEDY MECHANICAL INC. AND NO PARTTHEREOF SHALL BE UTILIZED BY ANY PERSON, FIRM, ORCORPORATION FOR ANY PURPOSE WHATSOEVER EXCEPTWITH THE SPECIFIC WRITTEN PERMISSION OF KENNEDYMECHANICAL INC. ALL RIGHTS RESERVED11 COMFORT STREETROCHESTER, NEW YORK 14620585-232-2800Rochester, NY 14625585-313-5819625 Panorama Trail, Building 2, Suite 210Baumer Mechanical Design Services12/10/2014 1:00:13PMM101APARTMENTBLDG./THSECOND FLOORPLANS - HVAC7/18/2014ITHACA, NYSTONE QUARRY APARTMENTS, LLCSTONE QUARRY APARTMENTS2012059KAG/JTB 1/8" = 1'-0"1APARTMENT BLDG. SECOND FLOOR PLAN - HVAC 1/8" = 1'-0"2TYPICAL TOWNHOME SECOND FLOOR PLAN - HVACREVISION SCHEDULENAME DATE15 AUG 2014SECOND FLOOR HVAC PLAN DRAWING NOTES1 PROVIDE SHEET METAL PLENUM SAME SIZE AS EVAPORATOR CONNECTION.2 FURNACE ACCESS AREA. KEEP FREE OF OBSTRUCTION.3 7" EXHAUST DUCT DOWN TO RANGE HOOD.PROVIDE A DUCT TRANSITION AS REQURIED TO MAKE THE FINAL CONNECTION TO THE RANGE HOOD. RANGE HOOD IS PROVIDED BYOTHERS.4 PROVIDE WALL CAP OUTLET. THE WALL CAP OUTLET SHALL BE A HOODED TYPE SELECTED FROM THE SIDING MANUFACTURERS STANDARDS. THE HOOD SHALL BE VINYLCONSTRUCTION WITH A BACKDRAFT DAMPER. COLOR SHALL BE SELECTED BY THE ARCHITECT. COORDINATE EXACT LOCATION WITH THE ARCHITECT ELEVATIONS.5 DUCTWORK SHALL BE INSTALLED IN THE SOFFITS. TEST THE DUCTWORK BEFORE THE SOFFITS ARE CLOSED UP. COORDINATE WITH APPLICABLE TRADES.6 PROVIDE 7" KITCHEN EXHAUST DUCT THROUGH SIDEWALL ON THE 1ST/2ND FLOORS.7 BATHROOM EXHAUST DUCT UP THROUGH ROOF.8 13x20 SUPPLY DUCT DOWN FROM FURNACE PLENUM TO FLOOR BELOW.# REF.DWREF.DWREF.REF.REF.DWDWREF.DWREF.DW7"ø16x12TRANSFER6" A.F.F.6"øT: 7'-9"B: 7'-3"6"øT: 7'-9"B: 7'-3"T: 7'-9"B: 7'-3"T: 8'-3"B: 7'-9"6"ø7"ø6"øT: 7'-9"B: 7'-3"T: 8'-11"B: 8'-4"10x45012x612516x12TRANSFER6" A.F.F.16x12TRANSFER6" A.F.F.6"øT: 8'-10"B: 8'-4"16x12TRANSFER6" A.F.F.16x12TRANSFER6" A.F.F.16x12TRANSFER6" A.F.F.7"ø6"ø18"x8"T: 7'-10"B: 7'-2"T: 8'-10"B: 8'-4"16x12TRANSFER6" A.F.F.16x12TRANSFER6" A.F.F.6"ø18"x8"6"ø16x12TRANSFER6" A.F.F.6"øT: 8'-10"B: 8'-4"7"ø6"øT: 8'-10"B: 8'-4"NO WALL TRANSFER LOCATIONUNDERCUTTHE DOOR?6"ø6"ø6"ø5"ø6"ø18"x8" 16"x8"6"ø5"ø6"ø6"ø6"ø5"ø7"ø7"ø18"x8"16"x8"5"ø6"ø6"ø6"ø6"ø6"ø18"x8"16"x8"5"ø6"ø6"ø18"x8"6"ø5"ø5"ø6"ø5"ø6"ø7"ø6"ø12x612512x612510x47510x45010x45012x612510x45012x612512x612512x612512x612510x45012x612512x612510x45012x612512x612510x47512x612512x612510x47512x612512x612510x45012x612512x6125T: 7'-10"B: 7'-2"T: 7'-9"B: 7'-3"T: 7'-9"B: 7'-3"T: 8'-10"B: 8'-3"T: 8'-10"B: 8'-3"T: 7'-10"B: 7'-2"T: 7'-9"B: 7'-3"T: 7'-9"B: 7'-4"T: 7'-10"B: 7'-2"T: 8'-11"B: 8'-4"T: 7'-10"B: 7'-2"T: 7'-10"B: 7'-2"T: 7'-9"B: 7'-3"T: 7'-10"B: 7'-2"T: 7'-9"B: 7'-3"T: 7'-9"B: 7'-3"T: 7'-10"B: 7'-2"T: 7'-10"B: 7'-2"T: 7'-9"B: 7'-3"T: 7'-9"B: 7'-4"T: 7'-9"B: 7'-3"T: 7'-10"B: 7'-2"T: 7'-9"B: 7'-4"T: 7'-10"B: 7'-2"T: 7'-9"B: 7'-3"T: 7'-9"B: 7'-4"T: 7'-9"B: 7'-3"T: 7'-10"B: 7'-3"T: 7'-9"B: 7'-4"NEW SOFFITNEW SOFFITNEW SOFFITNEW SOFFITNEW SOFFITNEW SOFFITNEW SOFFITNEW SOFFITNEW SOFFITT: 8'-11"B: 8'-4"T: 8'-10"B: 8'-4"16x12TRANSFER6" A.F.F.10x475T: 7'-10"B: 7'-3"T: 7'-9"B: 7'-3"6"ø6"ø12x6125T: 7'-9"B: 7'-3"12x6125T: 8'-10"B: 8'-4"6"ø6"ø6"øT: 7'-9"B: 7'-3"DSS-AEF-1FURN-AFURN-AEF-1FURN-AEF-1EF-1FURN-AEF-1FURN-AEF-1EF-111111222222333333344444444445555555555555666664EF-212x612512"x8"5"ø5"ø12"x8"12"x8"16"x8"12"x8" 14"x8" 12"x8"12x6125OA INTAKE WALL CAPT: 7'-9"B: 7'-5"4"ø4"ø1CVKCVKABCDEFGABCDEFG1234567891012345678910WARNING: It is a violation ofNew York State Law for anyperson, unless acting under thedirection of a licensed Architect,to alter this document in any way.If a document bearing the seal ofan Architect is altered, thealtering Architect shall affix tosuch document his seal and thenotation "altered by" followed byhis signature, the date of suchalteration, and a specificdescription of the alteration.ArchitecturePlanningInterior Design217 North Aurora StreetIthaca NY 14850p 607.273.7600 f 607.273.0475DATE:PROJECT:OTHER:DRAWN BY:THESE DOCUMENTS AND ALL IDEAS, ARRANGEMENT,DESIGNS AND PLANS INDICATED THEREON ORPRESENTED THEREBY ARE OWNED AND REMAIN THEPROPERTY OF KENNEDY MECHANICAL INC. AND NO PARTTHEREOF SHALL BE UTILIZED BY ANY PERSON, FIRM, ORCORPORATION FOR ANY PURPOSE WHATSOEVER EXCEPTWITH THE SPECIFIC WRITTEN PERMISSION OF KENNEDYMECHANICAL INC. ALL RIGHTS RESERVED11 COMFORT STREETROCHESTER, NEW YORK 14620585-232-2800Rochester, NY 14625585-313-5819625 Panorama Trail, Building 2, Suite 210Baumer Mechanical Design Services12/10/2014 1:00:37PMM102APARTMENTBLDG./TH THIRDFLOOR ANDROOF /ATTICPLANS - HVAC7/18/2014ITHACA, NYSTONE QUARRY APARTMENTS, LLCSTONE QUARRY APARTMENTS2012059KAG/JTB 1/8" = 1'-0"1APARTMENT BLDG. THIRD FLOOR PLAN - HVAC 1/8" = 1'-0"2TYPICAL TOWNHOME ROOF PLAN - HVACREVISION SCHEDULENAME DATE15 AUG 2014THIRD FLOOR HVAC PLAN DRAWING NOTES1 PROVIDE SHEET METAL PLENUM SAME SIZE AS EVAPORATOR CONNECTION.2 FURNACE ACCESS AREA. KEEP FREE OF OBSTRUCTION.3 7" EXHAUST DUCT DOWN TO RANGE HOOD.PROVIDE A DUCT TRANSITION AS REQURIED TO MAKE THE FINAL CONNECTION TO THE RANGE HOOD. RANGE HOOD IS PROVIDED BYOTHERS.4 PROVIDE WALL CAP OUTLET. THE WALL CAP OUTLET SHALL BE A HOODED TYPE SELECTED FROM THE SIDING MANUFACTURERS STANDARDS. THE HOOD SHALL BE VINYLCONSTRCTION WITH A BACKDRAFT DAMPER. COLOR SHALL BE SELECTED BY THE ARCHITECT. COORDINATE EXACT LOCATION WITH THE ARCHITECT ELEVATIONS.5 DUCTWORK SHALL BE INSTALLED IN THE SOFFITS. TEST THE DUCTWORK BEFORE THE SOFFITS ARE CLOSED UP. COORDINATE WITH APPLICABLE TRADES.6 PROVIDE 7" KITCHEN EXHAUST DUCT THROUGH SIDEWALL ON THE 1ST/2ND FLOORS.# ACC-1ACC-1ACC-1ACC-1ACC-1ACC-1ACC-1ACC-1ACC-1ACC-1ACC-1ACC-1ACC-1ACC-1ACC-1ACC-1ACC-1ACC-2DSS-ADSS-ADSS-AACC-1ACC-1CVKCVKCVKCVKCVKCVKCVKCVKCVKCVKCVKCVKCVKCVKCVKCVKCVKCVKCVKABCDEFGABCDEFG1234567891012345678910WARNING: It is a violation ofNew York State Law for anyperson, unless acting under thedirection of a licensed Architect,to alter this document in any way.If a document bearing the seal ofan Architect is altered, thealtering Architect shall affix tosuch document his seal and thenotation "altered by" followed byhis signature, the date of suchalteration, and a specificdescription of the alteration.ArchitecturePlanningInterior Design217 North Aurora StreetIthaca NY 14850p 607.273.7600 f 607.273.0475DATE:PROJECT:OTHER:DRAWN BY:THESE DOCUMENTS AND ALL IDEAS, ARRANGEMENT,DESIGNS AND PLANS INDICATED THEREON ORPRESENTED THEREBY ARE OWNED AND REMAIN THEPROPERTY OF KENNEDY MECHANICAL INC. AND NO PARTTHEREOF SHALL BE UTILIZED BY ANY PERSON, FIRM, ORCORPORATION FOR ANY PURPOSE WHATSOEVER EXCEPTWITH THE SPECIFIC WRITTEN PERMISSION OF KENNEDYMECHANICAL INC. ALL RIGHTS RESERVED11 COMFORT STREETROCHESTER, NEW YORK 14620585-232-2800Rochester, NY 14625585-313-5819625 Panorama Trail, Building 2, Suite 210Baumer Mechanical Design Services12/10/2014 1:00:49PMM103APARTMENTBLDG.ROOF/ATTICPLAN - HVAC7/18/2014ITHACA, NYSTONE QUARRY APARTMENTS, LLCSTONE QUARRY APARTMENTS2012059KAG/JTB 1/8" = 1'-0"1APARTMENT BLDG. ROOF PLAN - HVACREVISION SCHEDULENAME DATEFLUES FORDOMESTIC WATERHEATERS-COORDINATEWITH PLUMBINGCONTRACTOR 1.DUCT AND DIFFUSER SIZE AND TYPE AS SHOWN ON DRAWINGS.SUPPLY AIRDUCTSUPPLYDIFUSERVDNOTES:4NO SCALETYPICAL SUPPLY AIR DIFFUSER DETAILCEILINGGRIDSEAL ALL ANNULAR SPACESAT CEILING WHERE DIFFUSERBOOT OCCURS AS LISTED INENERGY STARREQUIREMENTSREGISTERCEILING12" MINIMUM2NO SCALEROUND OR RECTANGULARAS SPECIFIED ON DRAWINGSPLENUM BOX LENGTH ANDWIDTH EQUAL TO DUCTCONNECTION SIZEDUCT MOUNTEDVOLUME DAMPERAS CALLED FORON DRAWINGSINTEGRAL VOLUMEDAMPER AS CALLEDFOR ON SCHEDULESTYPICAL CEILING/SIDE WALLREGISTER INSTALLATION DETAILSEAL ALL ANNULAR SPACES ATCEILING WHERE REGISTER BOOTOCCURS AS LISTED IN ENERGY STARREQUIERMENTSCASED COOLING COILFURNACEWALLROUTE FURNANCE FLUES UPTHROUGH ROOF TOCONCENTRIC VENTTERMINATIONRETURN AIR TO TRANSFERVIA LOUVERED DOORS,OPEN SURFACE AREA TO BECOORDINATED WITH DOORSELECTIONWALL1/2" THICK NEOPRENEVIBRATION ISOLATION PADFLOORFINAL CONNECTION BYPLUMBING CONTRACTORFLUE CONDENSATENEUTRALIZER KITPITCH HORIZONTALFLUE PIPING BACKTOWARDS FURNACEPRIMARY CONDENSATE DRAINCONNECTIONFINAL CONNECTION BYPLUMBING CONTRACTORSECONDARY OVERFLOW DRAINFINAL CONNECTION BYPLUMBING CONTRACTORRETURN AIR DUCT SIZEAS NOTED ON PLANSCAULK AND SEALJOINT AIRTIGHTSUPPLY AIR DUCT SIZE ASNOTED ON PLANSPROVIDE BLOCK SUPPORTFOR RETURN AIRDUCTWORKAIR FILTER HOUSING5NO SCALETYPICAL APARTMENT FURNACE DETAILPROVIDE REFRIGERANT PIPINGBETWEEN EVAPPORATOR COIL AND AIRCOOLED CONDENSING UNIT PERMANUFACTURER'SRECOMMENDATIONS2" PVC COMBUSTION AIRINTAKE & EXHAUST PIPING4" Ø DRYER VENTDRYER BY OWNER6NO SCALEDRYER VENT DETAILROUTE DUCT TO TERMINATIONLOCATION SHOWN ON PLANSPROVIDE DRAW BAND CONNECTIONDRYERPROVIDE UL LISTED FLEXIBLE METALDUCTWORK CONNECTION TO DRYERNOTES:-DRYER VENT SHALL BE INSTALLED IN ACCORDINGWITH THE REQUIREMENTS OF THE MECHANICALCODE OF NEW YORK STATE-REFER TO ISOMETRIC VIEW THIS PAGE FOR MOREDETAILPROVIDE 90 DEGREE LONG TURNELBOW, PART NUMBER LT90. ASMANUFACTURED BY IN-O-VATETECHNOLOGIESNO SCALENO SCALECONCENTRIC VENT DETAILCOMBUSTION AIR INLETVENTROOF12"31.2.3.4.NOTE:DISTANCE FROM TOP OF VENT TO BOTTOM OF AIR INLET SHALLBE 12".COORDINATE INSTALLATION OF VENTS WITH OWNER. VENTS SHALLBE SYMMETRICAL. LINE UP ALL VENT PENETRATIONS HORIZONTALLYPAINT EXTERIOR VENT AND COMBUSTION AIR PIPING WITH EXTERIORFLAT PAINT. COLOR TO BE SELECTED BY ARCHITECT.THIS DETAIL SHALL APPLY TO BOILERS AND FURNACES.COORDINATE CUTTING AND PATCHING OF ROOF WITH GENERAL CONTRACTORLOCATE ALL ROOF PENETRATIONS ON REAR FACE OF ROOF. TRANSITION AND OFFSET AS REQUIRED.12" CLEARANCE SHALL BEMAINTAINED ABOVEHIGHEST ANTICIPATEDSNOW LEVEL. MAXIMUMNOT TO EXCEED 24" ABOVEROOF.FLASHING (TYP.)PROVIDE WEATHER TIGHTINSTALLATION5.6.1TYPICAL EXHAUST ROOF JACK DETAILNO SCALEINSULATE DUCTWORK INATTIC SPACE.ROOFCUT AND PATCH DRYWALL LIDAS REQUIRED TO INSTALL DUCTWORK.CEILINGSPACEPROVIDE ALUMINUM ROOF JACKWITH BACKDRAFT DAMPER,PRIME AND PAINT WITH HIGHQUALITY PAINT CUSTOM COLORSELECTED AND APPROVED BYARCHITECT.NOTES:1.COORDINATE ALL ROOF PENETRATION WORK WITH ROOFINGCONTRACTOR.I HOUR RATEDDRYWALL LIDPROVIDE SHEET METAL FIRESTOP FORDUCT SUPPORTFOR ALL ROOFING AND FLASHINGREQUIREMENTS. REFER TOARCHITECTURAL PLANSPROVIDE FIRE STOP PENETRATIONSYSTEM IN ACCORDANCE WITH ASTME814. INSTALL SYSTEM PERMANUFACTURERS' INSTALLATIONREQUIREMENTSDOWNFLOW FURNACECASED COOLING COILWALLROUTE FURNANCE FLUES UPTRHOUGH ROOF TOCONCENTRIC VENTTERMINATIONRETURN AIR GRILLE REFERTO SIZES INDICATED ONPLANSWALLSUPPORT BASE (BY SAME MFGAS FURNACE)SECOND FLOORFINAL CONNECTION BYPLUMBING CONTRACTORFLUE CONDENSATENEUTRALIZER KITPITCH HORIZONTALFLUE PIPING BACKTOWARDS FURNACEPRIMARY CONDENSATE DRAINCONNECTIONFINAL CONNECTION BYPLUMBING CONTRACTORSECONDARY OVERFLOW DRAINFINAL CONNECTION BYPLUMBING CONTRACTORCAULK AND SEALJOINT AIRTIGHTRETURN AIR DUCT SIZE ASNOTED ON PLANS7NO SCALETYPICAL TOWNHOUSE FURNACE DETAILPROVIDE REFRIGERANT PIPINGBETWEEN EVAPPORATOR COIL AND AIRCOOLED CONDENSING UNIT PERMANUFACTURER'SRECOMMENDATIONSAIR FILTER HOUSINGSUPPLY AIR DUCT SIZE ASNOTED ON PLANS2" PVC COMBUSTION AIRINTAKE & EXHAUST PIPING10"x8"12"x4"12"x4"12"x4"4"ø4"ø4"ø4"ø4"ø4"øLOUVER L-2WALL CAP(DRYER VENT)STACKED WASHER DRYER UNIT (TYP. OF 5)WASHING MACHINEDRYERABCDEFGABCDEFG1234567891012345678910WARNING: It is a violation ofNew York State Law for anyperson, unless acting under thedirection of a licensed Architect,to alter this document in any way.If a document bearing the seal ofan Architect is altered, thealtering Architect shall affix tosuch document his seal and thenotation "altered by" followed byhis signature, the date of suchalteration, and a specificdescription of the alteration.ArchitecturePlanningInterior Design217 North Aurora StreetIthaca NY 14850p 607.273.7600 f 607.273.0475DATE:PROJECT:OTHER:DRAWN BY:THESE DOCUMENTS AND ALL IDEAS, ARRANGEMENT,DESIGNS AND PLANS INDICATED THEREON ORPRESENTED THEREBY ARE OWNED AND REMAIN THEPROPERTY OF KENNEDY MECHANICAL INC. AND NO PARTTHEREOF SHALL BE UTILIZED BY ANY PERSON, FIRM, ORCORPORATION FOR ANY PURPOSE WHATSOEVER EXCEPTWITH THE SPECIFIC WRITTEN PERMISSION OF KENNEDYMECHANICAL INC. ALL RIGHTS RESERVED11 COMFORT STREETROCHESTER, NEW YORK 14620585-232-2800Rochester, NY 14625585-313-5819625 Panorama Trail, Building 2, Suite 210Baumer Mechanical Design Services12/10/2014 1:01:34PMM300HVAC DETAILS7/18/2014ITHACA, NYSTONE QUARRY APARTMENTS, LLCSTONE QUARRY APARTMENTS2012059KAG/JTBREVISION SCHEDULENAME DATE N.T.S.8ISOMETRIC VIEW AT LAUNDRY AREA