Loading...
HomeMy WebLinkAboutDemco ElectricalA B C D E F G A B C D E F G 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 Architecture Planning Interior Design 217 North Aurora Street Ithaca NY 14850 p 607.273.7600 f 607.273.0475 DATE: PROJECT: OTHER: DRAWN BY:SS, BR A3ITHACA, NYSTONE QUARRY APARTMENTS, LLCSTONE QUARRY APARTMENTSREVISION SCHEDULE NAME DATE 18 JULY 2014 2012059 DEMCO NEW YORK CORP. DOHN A. SIMS, P.E. :DUQLQJLWLVDYLRODWLRQRIWKH1<6WDWH(GXFDWLRQ/DZ IRUDQ\SHUVRQWRDOWHUWKLVGRFXPHQWLQDQ\ZD\XQOHVV acting under the direction of a licensed professional engineer. If a document bearing the seal of an engineer is altered, the altering engineer shall affix to the document their seal and the notation "altered by" followed by their signature and the date of such alteration, and a specific description of the alteration. ELECTRICAL CONTRACTORS 6701 MANLIUS CENTER RD EAST SYRACUSE, NEW YORK 13057 E1.0 Electrical Specifications and Drawing Index ELECTRICAL SPECIFICATIONS PART 1 - GENERAL RELATED DOCUMENTS: THE GENERAL PROVISIONS OF THE CONTRACT, INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONS AND GENERAL REQUIREMENTS, APPLY TO THE WORK SPECIFIED IN THIS SECTION. SAFETY: IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, THE CONTRACTOR SHALL BE SOLELY AND COMPLETELY RESPONSIBLE FOR CONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY AT ALL TIMES. SCOPE OF WORK: PROVIDE ALL MATERIALS AND EQUIPMENT (EXCEPT THOSE ITEMS SPECIFICALLY STATED IN THESE SPECIFICATIONS OR ON THE DRAWINGS AS BEING FURNISHED BY OWNER OR OTHERS), LABOR AND INCIDENTALS REQUIRED FOR THE ELECTRICAL WORK AS INDICATED IN THESE SPECIFICATIONS AND DRAWINGS, AND AS REQUIRED TO MAKE A COMPLETE AND OPERATING INSTALLATION TO THE SATISFACTION OF THE OWNER AND THE ENGINEER. FURNISH COMPETENT SUPERVISION OF THE WORK TO BE PERFORMED AT ALL TIMES DURING PROGRESS OF THE WORK. THE WORK INCLUDES (BUT IS NOT NECESSARILY LIMITED TO) THE FOLLOWING: ALL REQUIRED ELECTRICAL SYSTEM COMPONENTS FOR SERVICE, FEEDERS AND BRANCH CIRCUIT WIRING FOR LIGHTING AND POWER. EMERGENCY SYSTEM WIRING AND COMPONENTS. GROUNDING. CONDUITS AND FITTINGS. PULL BOXES AND JUNCTION BOXES. MOTOR SWITCHES AND DISCONNECTS CONNECTION AND COORDINATION FOR MOTOR CONTROLLERS. LIGHTING FIXTURES. WIRING DEVICES. SENSORS, WIRING, CONDUIT FOR CONTROLS AND APPLICABLE TO ELECTRICAL CONTRACT ONLY. WIRING, CONDUIT, AND CONNECTIONS TO EQUIPMENT THAT MAY BE PROVIDED UNDER ANOTHER DIVISION OF THESE SPECIFICATIONS THAT ARE INCLUDED IN CONTRACT FOR ELECTRICAL WORK. WIRING, AND CONNECTING ELECTRICAL EQUIPMENT THAT IS TO BE FURNISHED BY THE OWNER. ELECTRICAL WORK INCIDENTAL TO THE REQUIREMENTS OF THE MECHANICAL SYSTEM. FIRE ALARM SYSTEM WHERE APPLICABLE TO ELECTRICAL CONTRACT. RACEWAY AND CABLING FOR DATA SYSTEMS. TEMPORARY WIRING AS REQUIRED FOR OTHER BUILDING FUNCTIONS DURING PERFORMANCE OF ELECTRICAL WORK. TESTING OF ELECTRICAL EQUIPMENT AND WIRING. DRAWINGS: THE DRAWINGS SHALL SERVE TO INDICATE THE GENERAL LAYOUT OF THE VARIOUS ITEMS OF EQUIPMENT. HOWEVER, LAYOUT OF ANY EQUIPMENT, ACCESSORIES, SPECIALTIES, WIREWAYS, AND CONDUIT SYSTEMS ARE DIAGRAMMATIC UNLESS SPECIFICALLY DIMENSIONED, AND DO NOT NECESSARILY INDICATE EVERY REQUIRED FITTING, JUNCTION BOX, PULL BOX, OR SIMILAR ITEMS REQUIRED FOR THE COMPLETE INSTALLATION. JOB CONDITIONS: CAREFULLY INVESTIGATE STRUCTURAL CONDITIONS, WALL, FURRING AND CHASE LOCATIONS, AND ROOM FINISHES AND MAKE ACTUAL MEASUREMENTS ON THE JOB SO THAT ALL EQUIPMENT SUCH AS PANELBOARDS, SWITCHES, RECEPTACLES, LIGHTING FIXTURES, FIRE ALARM DEVICES AND ACCESSORIES SHALL FIT. PRACTICAL CONSIDERATION SHALL BE GIVEN TO COORDINATION OF ALL VISIBLE DEVICES WITH AESTHETIC AND ARCHITECTURAL DESIGN ELEMENTS. OBTAIN FROM THE OWNER A COMPLETE UNDERSTANDING OF TRAINING AND REQUIRED PERSONAL PROTECTIVE EQUIPMENT NECESSARY FOR WORKING ON THIS SITE. VERIFY ALL MEASUREMENTS AND BE RESPONSIBLE FOR THE CORRECTNESS OF SAME BEFORE ORDERING ANY MATERIALS OR DOING ANY WORK. NO EXTRA CHARGE OR COMPENSATION WILL BE ALLOWED BECAUSE OF ANY DIFFERENCE BETWEEN THE ACTUAL MEASUREMENTS AND THOSE INDICATED ON THE DRAWINGS. ANY RELEVANT DIFFERENCE WHICH MIGHT BE DISCOVERED BY THE CONTRACTOR SHALL BE SUBMITTED TO THE ENGINEER FOR CONSIDERATION BEFORE PROCEEDING WITH THE WORK. LAW AND PERMITS: THE LATEST PUBLISHED REGULATIONS OF THE STATE AND LOCAL BUILDING CODES, NATIONAL FIRE PROTECTION ASSOCIATION (NFPA), OSHA (REGARDING CONSTRUCTION PRACTICES) AND NATIONAL ELECTRICAL CODE, WITH THE LATEST TENTATIVE INTERIM AMENDMENTS, SHALL BE CONSIDERED AS INCLUDED IN THESE SPECIFICATIONS, AND ALL APPLICABLE REQUIREMENTS SHALL BE FULLY COMPLIED WITH. QUESTIONS REGARDING INTERPRETATION SHALL BE ADDRESSED TO THE PROJECT ARCHITECT. APPLY FOR PERMITS, LICENSES AND INSPECTION CERTIFICATES AND PAY ALL FEES INCIDENTAL TO THE ELECTRICAL WORK. GIVE NOTICE TO THE PROPER AUTHORITIES IN AMPLE TIME FOR THE WORK TO BE INSPECTED AND APPROVED AS IT PROGRESSES, AND CONCEAL NO WORK UNTIL APPROVED BY THE ELECTRICAL INSPECTORS HAVING JURISDICTION. THE NATIONAL ELECTRICAL CODE AND ALL STATE AND LOCAL RULINGS SHALL BE OBSERVED AND SHALL GOVERN THE CHARACTER OF THIS WORK. SHOULD THE DRAWINGS OR THESE SPECIFICATIONS IN ANY WAY CONFLICT WITH THE CODE, STATE OR LOCAL RULES AND/OR REGULATIONS, PROMPTLY NOTIFY THE ENGINEER IN WRITING IN ORDER THAT NECESSARY CHANGES CAN BE ACCOMPLISHED BY APPROPRIATE MODIFICATION. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO MEET THE REQUIREMENTS OF CODES, RULES AND REGULATIONS APPLICABLE TO ELECTRICAL WORK AT THIS SITE. UPON COMPLETION OF THE INSTALLATION, A CERTIFICATE OF APPROVAL FROM THE ELECTRICAL INSPECTION DEPARTMENT HAVING JURISDICTION THEREON SHALL BE FURNISHED TO THE OWNER, PRIOR TO FINAL PAYMENT, AND ALL FEES SHALL BE PAID BY THE ELECTRICAL CONTRACTOR. PROVIDE TESTING AND RECORDS OF COMPLETION FOR ALL FIRE ALARM MODIFICATIONS AND HIGH VOLTAGE CONNECTIONS. THE CERTIFICATE OF INSPECTION SHALL NOT RELEASE THE CONTRACTOR FROM ANY GUARANTEE OF WARRANTY OBLIGATIONS SET FORTH IN THESE SPECIFICATIONS. GUARANTEE: ALL MATERIALS AND WORKMANSHIP SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR FROM THE DATE OF ACCEPTANCE OF THE PROJECT AS SUBSTANTIALLY COMPLETED IN ACCORDANCE WITH THE DRAWINGS AND SPECIFICATIONS, OR WHEN BENEFICIALLY USED BY THE OWNER, WHICHEVER FIRST OCCURS AS CERTIFIED BY THE PROJECT ARCHITECT. DEFECTS DUE TO FAULTY MATERIALS, METHODS OF INSTALLATION OR WORKMANSHIP SHALL BE REPAIRED OR REPLACED PROMPTLY WITH THE LEAST INCONVENIENCE AND WITHOUT EXPENSE TO THE OWNER, DURING THE HOURS AND IN A TIME FRAME AS DESIGNATED BY THE ENGINEER. THIS GUARANTEE IS AN ADDITION TO ANY SPECIFIC PERFORMANCE GUARANTEES CALLED FOR IN THE INDIVIDUAL PARAGRAPHS. SUBMIT REQUIRED COPIES OF ALL WARRANTIES AND GUARANTEES FOR SYSTEMS, EQUIPMENT, DEVICES AND MATERIALS (THIS INCLUDES COPIES FOR MAINTENANCE MANUALS). SUBMITTAL AND SHOP DRAWINGS: SUBMIT FOR REVIEW ALL REQUESTED PRODUCT DATA, SHOP DRAWINGS AND SAMPLES. SUBMIT REQUIRED COPIES OF ALL CUTS, CATALOGUES, BULLETINS, DIAGRAMS, CURVES, ETC. TRADE NAMES, MANUFACTURERS, AND CATALOG NUMBERS ARE MENTIONED HEREIN AND ON THE DRAWINGS SOLELY IN ORDER TO ESTABLISH A STANDARD FOR THE TYPE, GENERAL DESIGN, AND QUALITY OF PRODUCT REQUIRED. OTHER PRODUCTS SIMILAR IN DESIGN OF EQUAL QUALITY CAPABLE OF FITTING WITHIN THE SPACES ALLOCATED AND COMPLYING WITH THE DRAWINGS AND SPECIFICATIONS WILL BE CONSIDERED. DIMENSIONAL DATA AND WEIGHTS SHALL BE INCLUDED. CONTRACTOR SHALL REVIEW SUBMITTALS AND SHOP DRAWINGS BEFORE FORWARDING THEM TO PROJECT ARCHITECT. SUBMITTALS AND DRAWINGS WILL BE RETURNED AFTER REVIEW INDICATING WHETHER OR NOT EXCEPTIONS ARE TAKEN AND THE REQUIRED PROCEDURE TO BE FOLLOWED THEREAFTER. RESUBMISSION OF REVISED SUBMITTALS AND SHOP DRAWINGS IS REQUIRED BEFORE CONSTRUCTION STARTS, UNLESS OTHERWISE NOTED IN CONTRACT OR ON RETURNED SUBMITTALS. CORRECTIONS OR COMMENTS MADE ON THE SUBMITTALS AND DRAWINGS DURING THIS REVIEW DO NOT RELIEVE THE CONTRACTOR FROM COMPLIANCE WITH THE REQUIREMENTS OF THE DRAWINGS AND SPECIFICATIONS. THIS REVIEW IS FOR GENERAL CONFORMANCE WITH THE DESIGN CONCEPT OF THE PROJECT AND GENERAL COMPLIANCE WITH THE INFORMATION GIVEN IN THE CONTRACT DOCUMENTS. THE CONTRACTOR IS RESPONSIBLE FOR CONFIRMING AND CORRELATING ALL QUANTITIES AND DIMENSIONS, SELECTING FABRICATION PROCESSES AND TECHNIQUES OF CONSTRUCTION. THE PRODUCTS LISTED BELOW SHALL BE SUBMITTED FOR REVIEW AFTER THE AWARD OF THE CONTRACT AND BEFORE ANY EQUIPMENT OR MATERIALS ARE PURCHASED. IF A PRODUCT IS UNACCEPTABLE, ANOTHER PRODUCT SHALL BE SUBMITTED. PROVIDE SUBMITTALS FOR THE FOLLOWING WHERE INCLUDED IN ELECTRICAL CONTRACT: LIGHTING FIXTURES AND LAMPS WIRING DEVICES AND DEVICE PLATES TRANSFORMERS SWITCHGEAR AND CONNECTING BUS WHERE APPLICABLE PANELBOARDS CIRCUIT BREAKERS FOR PANELBOARDS ENCLOSED SWITCHES AND DISCONNECTS FUSES ETHERNET CABLE SENSORS AND TRANSMITTERS FIRE ALARM DEVICES INCLUDED IN WORK ELECTRICAL IDENTIFICATION: PROVIDE LAMINATED IDENTIFICATION PLATES FOR MAJOR ITEMS OF ELECTRICAL EQUIPMENT AND AS REQUIRED BY ELECTRICAL CONTRACT AND INCLUDE: ENCLOSED SWITCHES, CIRCUIT BREAKERS AND DISCONNECTS SWITCHBOARDS AND PANELBOARDS STANDARDS AND REGULATIONS: THE WORK UNDER THIS DIVISION SHALL COMPLY WITH THE LATEST EDITION OF THE APPLICABLE STANDARDS AND CODES OF THE FOLLOWING: UL - UNDERWRITER'S LABORATORIES, INC. NEMA - NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION NEC - NATIONAL ELECTRICAL CODE, NFPA 70 STATE AND LOCAL CODES, RULES AND REGULATIONS ANSI -AMERICAN NATIONAL STANDARDS INSTITUTE NFPA -NATIONAL FIRE PROTECTION ASSOCIATION INCLUDE ALL ITEMS OF LABOR AND MATERIALS REQUIRED TO COMPLY WITH SUCH STANDARDS AND CODES. WHERE QUANTITIES, SIZES OR OTHER REQUIREMENTS INDICATED ON THE DRAWINGS, OR HEREIN SPECIFIED ARE IN EXCESS OF THE REQUIREMENTS OF THE STANDARDS AND CODES, THE SPECIFICATIONS AND/OR DRAWINGS SHALL GOVERN. RECORD DRAWINGS: UPON COMPLETION OF THE PROJECT, FURNISH A COMPLETE SET OF REPRODUCIBLE DRAWINGS WHICH WILL INCLUDE ALL REVISIONS, SKETCHES, ETC., WHICH MAY HAVE BEEN REQUIRED DURING CONSTRUCTION. THE CONTRACTOR SHALL MARK THESE DRAWINGS TO INDICATE EXACT, AS INSTALLED CONDITIONS. THE AS-INSTALLED CONDITIONS SHALL REFLECT ANY CHANGES IN EQUIPMENT LOCATION OR ROUTING WHICH DID NOT FOLLOW THAT SHOWN ON THE CONTRACT DRAWINGS AND CHANGES IN CONDUIT AND/OR WIRING SIZES. DURING COURSE OF THE INSTALLATION, CONTRACTOR SHALL MAINTAIN A SEPARATE SET OF DRAWINGS FOR MARKING AND NOTING ALL INSTALLATION DEVIATIONS. THIS SET OF DRAWINGS SHALL BE MAINTAINED CONTINUOUSLY, AND SHALL BE USED FOR NO OTHER PURPOSE THAN INDICATING AS-INSTALLED CONDITIONS. PART 2 - PRODUCTS: MATERIALS: UNLESS OTHERWISE SPECIFIED, ALL MATERIALS SHALL BE NEW AND UNUSED AND SHALL BE LISTED BY UNDERWRITERS' LABORATORIES, INC., FOR THE SERVICE INTENDED, EXCEPT AS PROVIDED IN CONTRACT. COMPATIBILITY: PROVIDE PRODUCTS WHICH ARE COMPATIBLE WITH OTHER PRODUCTS OF THE ELECTRICAL WORK, AND WITH OTHER WORK REQUIRING INTERFACE WITH THE ELECTRICAL WORK, INCLUDING ELECTRICAL CONNECTIONS AND CONTROL DEVICES. FOR EXPOSED ELECTRICAL WORK, COORDINATE COLORS AND FINISHES WITH OTHER WORK. DETERMINE IN ADVANCE OF PURCHASE THAT EQUIPMENT AND MATERIALS PROPOSED FOR INSTALLATION WILL FIT LEAVING ADEQUATE CLEARANCE AS REQUIRED BY APPLICABLE CODES, AND FOR ADJUSTMENT, REPAIR, OR REPLACEMENT. MANUFACTURERS NAMEPLATES: EACH MAJOR COMPONENT OF THE EQUIPMENT SHALL HAVE THE MANUFACTURER'S NAME, ADDRESS, MODEL NUMBER, AND RATING ON A PLATE SECURELY AFFIXED IN A CONSPICUOUS PLACE. THE NAMEPLATE OF DISTRIBUTING AGENT WILL NOT BE ACCEPTABLE. NEMA CODE RATINGS, OR OTHER DATA WHICH ARE DIE-STAMPED INTO THE SURFACE OF THE EQUIPMENT SHALL BE STAMPED IN AN EASILY VISIBLE LOCATION. PRODUCT, DELIVER, STORAGE, AND HANDLING: ENSURE THAT ALL ELECTRICAL EQUIPMENT, DEVICES, AND MATERIALS ARRIVE AT THE SITE IN GOOD CONDITION, INTACT IN FACTORY PACKAGE OR CRATE. ANY EQUIPMENT FOUND TO BE DAMAGED SHALL BE REMOVED FROM THE PROJECT SITE. HAVE PERSONNEL ON-SITE TO RECEIVE SHIPMENTS. DO NOT USE OWNER'S EMPLOYEES TO ACCEPT SHIPMENTS. STORE AND PROTECT FROM DAMAGE ALL ELECTRICAL EQUIPMENT, DEVICES, AND MATERIALS IN FACTORY CONTAINERS OR PACKAGE UNTIL READY FOR USE. STORAGE FACILITY SHALL BE A CLEAN, DRY, INDOOR SPACE WHICH PROVIDES PROTECTION AGAINST WEATHER. AVOID DAMAGE BY CONDENSATION BY PROVIDING TEMPORARY HEATING WHEN REQUIRED. HANDLE ALL ELECTRICAL EQUIPMENT, DEVICES, AND MATERIALS CAREFULLY TO PREVENT BREAKAGE, DENTING, OR SCORING OF THE FINISH. DAMAGED MATERIALS SHALL BE REMOVED FROM THE PROJECT SITE. TOUCH UP ALL MARRED SURFACES. CONDUIT: CONDUIT SHALL BE AS INDICATED ON THE DRAWINGS. NO CONDUIT SMALLER THAN 1/2" DIAMETER SHALL BE USED, UNLESS NOTED OTHERWISE HEREIN OR ON DRAWINGS. USE SHORT PIECES OF FLEXIBLE CONDUIT FOR CONNECTIONS TO MOTORS AND MOVING OR VIBRATING EQUIPMENT. USE LIQUID TIGHT IN ALL WET/DAMP LOCATIONS. BOXES: BOXES SHALL BE OF STANDARD SIZES SUITABLE FOR THE USE INTENDED. USE CAST FS BOXES IN DAMP OR WET AREAS. GALVANIZED STAMPED BOXES MAY BE USED IN GENERAL AREAS INSIDE. WALL OUTLETS FOR SWITCHES, RECEPTACLES, ETC., SHALL BE SUITABLE FOR DEVICE WITH APPROPRIATE DEVICE RING FOR THE APPLICATION. BOXES OUTDOOR, WHERE REQUIRED, SHALL BE CAST FS TYPE, WITH WEATHERPROOF COVER. GROUNDING: GROUND CONDUITS, BOXES, MOTOR FRAMES, FIXTURE BODIES AND RECEPTACLE GROUND TERMINALS. MAINTAIN GROUND CONTINUITY THROUGH CONDUITS. PROVIDE SEPARATE GROUND CONDUCTORS IN CIRCUITS. PROVIDE GROUNDING ELECTRODE SYSTEMS FOR SERVICE AND SEPARATELY DERIVED GROUNDING SYSTEM FOR DISTRIBUTION TRANSFORMERS. PANELBOARDS: PROVIDE PANELBOARD, AS SCHEDULED, BY SUITABLE MANUFACTURER: SQUARE-D, CUTLER HAMMER/EATON, GENERAL ELECTRIC, OR ITE. EXISTING REVISED AND NEW CIRCUIT DIRECTORIES SHALL BE NEATLY PRODUCED BY TYPEWRITTEN METHOD TO REFLECT LOADS AS INSTALLED. PROVIDE ADDITIONAL CIRCUIT BREAKERS AS REQUIRED TO COMPLY WITH DRAWING REQUIREMENTS. CIRCUIT BREAKERS TO BE COMPATIBLE WITH RATINGS, TYPE, QUALITY OF PANEL IN WHICH THEY ARE TO BE INSTALLED. WIRE: UNLESS OTHERWISE SPECIFIED, WIRE FOR THE VARIOUS SERVICES SHALL BE OF THE FOLLOWING TYPES: BRANCH LIGHTING AND POWER CIRCUITS, TYPE "THW", "THWN", THWN-2 OR "THHN" SUITABLE FOR DRY AND WET LOCATIONS. INSTALL ALL THE CIRCUITS ON ROOF USING XHHW-2 IN GALVANIZED CONDUIT ON APPROVED ROOF SUPPORTS. MINIMUM GAUGES (AWG) ARE AS INDICATED OR AS REQUIRED BY CODE FOR THE APPLICATIONS. OTHER WIRE SHALL BE NO SMALLER THAN 12 GAUGE (AWG) UNLESS OTHERWISE NOTED. SIZES #8 AND LARGER SHALL BE STRANDED. WIRING SHALL BE COLOR CODED, PER STANDARD AT SITE. ENCLOSED SWITCHES AND DISCONNECTS: HD NEMA 1 INDOORS IN DRY LOCATIONS AND NEMA 3R FOR EXTERIOR OR DAMP/WET AREAS, UNLESS OTHERWISE NOTED AS MANUFACTURED BY SQ. D, CUTLER HAMMER/EATON, GENERAL ELECTRIC, OR ITE. WIRING DEVICES: EXCEPT AS NOTED OTHERWISE SWITCHES SHALL BE 20 AMP, 120/277 VOLT SILENT TYPE, SINGLE POLE, OR THREE WAY AS REQUIRED; RECEPTACLES SHALL BE DUPLEX, GROUNDING TYPE, 20 AMPERE, 125 VOLT, 3 WIRE. WHERE INDICATED OR REQUIRED, USE GFI RATED RECEPTACLES AND WHERE DAMP OR WET, USE WEATHER-PROOF COVERS TO PROTECT THE DEVICES. SWITCH AND RECEPTACLE PLATES: ALL SWITCH, RECEPTACLE AND OUTLET DEVICES PLATES SHALL MATCH STANDARDS AT THE SITE, AND ALL PLATES FOR MULTIPLE GANG REQUIREMENTS SHALL BE ONE-PIECE CONSTRUCTION. PLATES SHALL BE PROVIDED WITH GASKETS WHERE REQUIRED. FINISHES FOR WALL SWITCHES AND WALL RECEPTACLES: FINISHES FOR ALL RECEPTACLES AND SWITCHES AND SIMILAR EXPOSED DEVICES SHALL BE COLOR COORDINATED TO MATCH WALL FINISH- IVORY, BROWN, OR STAINLESS. LIGHTING FIXTURES: UNLESS OTHERWISE NOTED, ALL LIGHTING FIXTURES SHALL BE NEW. FURNISH ALL REQUIRED EQUIPMENT, ACCESSORIES, MOUNTING HARDWARE AND LAMPS. BALLASTS SHALL BE ELECTRONIC, CBM RATED, ETL TESTED AND APPLICABLE TO THE NEW YORK STATE ENERGY CODE WITH LAMPS. FIXTURES SHALL BE AS SCHEDULED. EMERGENCY/EGRESS LIGHTING UNITS SHALL HAVE ALTERNATE POWER SOURCE TO MEET CODE REQUIREMENT FOR 90 MINUTES OF OPERATION IN THE EVENT OF A POWER FAILURE. PART 3 - EXECUTION: WORKMANSHIP: WORKMANSHIP SHALL CONFORM TO APPROVED ELECTRICAL INSTALLATION PRACTICE. EQUIPMENT AND ACCESSORIES AS INSTALLED SHALL BE COMPLETE AND OPERATING. THE EXACT LOCATION AND ARRANGEMENT OF MATERIAL AND EQUIPMENT SHALL BE DETERMINED AS WORK PROGRESSES TO CONFORM IN THE BEST POSSIBLE MANNER WITH RELATED WORK OF OTHER CRAFTS. THE WORK IN ALL DETAILS IS SUBJECT TO THE APPROVAL OF THE OWNER. ANY WORK OR MATERIAL WHICH IS REJECTED MUST BE REMOVED AND REPLACED IMMEDIATELY. PROTECTION OF FIXTURES, MATERIAL AND EQUIPMENT: CONTINUOUSLY MAINTAIN ADEQUATE PROTECTION OF STORED MATERIALS AND INSTALLED WORK. PROTECT FIXTURES AND EQUIPMENT AGAINST DIRT, RUST, MOISTURE, CHEMICAL AND MECHANICAL INJURY. DO NOT STORE MATERIALS AND EQUIPMENT DIRECTLY ON THE GROUND AND/OR IN AREAS WHERE THEY WILL BE SUBJECT TO PHYSICAL INJURY FROM VEHICULAR TRAFFIC OR CONSTRUCTION MACHINERY. DO NOT ALLOW CONDUIT AND EQUIPMENT INSTALLED TO BE USED BY OTHER TRADES AS SUPPORTS FOR SCAFFOLDS OR PERSONNEL. DELICATE EQUIPMENT SHALL NOT BE DELIVERED TO THE JOB SITE UNLESS IT CAN BE PLACED IN COMPLETED AND PROTECTED AREAS. CAP OR PLUG ALL CONDUIT OPENINGS DURING INSTALLATION. AT THE COMPLETION OF THE WORK, EQUIPMENT, FIXTURES, EXPOSED SUPPORTS, AND PIPING SHALL BE CLEANED TO THE SATISFACTION OF THE ARCHITECT. CLEANING AND HOUSEKEEPING: REMOVE ALL DEBRIS, SURPLUS MATERIALS OR FOREIGN MATTER (CAUSED BY THE PERFORMANCE OF THE ELECTRICAL WORK) FROM THE PREMISES. ON COMPLETION OF THE WORK, THE CONTRACTOR SHALL BE RESPONSIBLE FOR LEAVING THE PREMISES IN A CLEAN CONDITION TO THE SATISFACTION OF THE ARCHITECT AND OWNER. KEEP STOCKS OF MATERIAL AND EQUIPMENT STORED ON THE PREMISES IN A NEAT AND ORDERLY MANNER, IN A STORAGE AREA AS DIRECTED BY GENERAL CONTRACTOR. LINES AND LEVEL: CONTRACTOR SHALL BE RESPONSIBLE FOR THE LINES AND LEVELS FOR THE ELECTRICAL EQUIPMENT, WIREWAYS, AND CONDUIT SYSTEMS BASED ON REFERENCE LINES AND BENCH MARKS ESTABLISHED BY THE CONTRACTOR FOR THE GENERAL WORK. TEMPORARY WIRING, LIGHTING AND POWER AT THE SITE: PROVIDE PROVISIONS FOR TEMPORARY LIGHT AND POWER DURING THE CONSTRUCTION PERIOD CONFORMING TO ALL LOCAL CODE AND STATE LABOR LAW REQUIREMENTS. PROVIDE AND MAINTAIN ALL TEMPORARY SERVICE EQUIPMENT AS REQUIRED UNTIL PERMANENT SERVICE IS INSTALLED AND "ALIVE". SWITCH-OVER OF TEMPORARY SYSTEMS TO THE PERMANENT SERVICE WHEN PERMANENT SERVICE IS READY FOR TRANSFER OF ELEMENTS. PROVIDE AND MAINTAIN TEMPORARY SERVICE, AND SWITCH "ON" AND "OFF" ON ALL REGULAR WORKING DAYS A COMPLETE TEMPORARY LIGHT SYSTEM FOR THE SECTION OF THE BUILDING WHILE UNDER CONSTRUCTION. PROVIDE AND MAINTAIN TEMPORARY FEEDERS TO PERMANENT MECHANICAL EQUIPMENT REQUIRING SERVICE BEFORE PERMANENT FEEDERS ARE READY FOR SAME. PROVIDE ANY AND/OR ALL RELOCATIONS OF THE TEMPORARY ELECTRIC FACILITIES AS NECESSARY TO CLEAR THE PERMANENT INSTALLATIONS OF ALL TRADES. WORK RELATED TO EQUIPMENT NOT FURNISHED AS WORK OF THIS DIVISION OF THE SPECIFICATIONS: UNLESS SPECIFICALLY INDICATED OTHERWISE, ANY REQUIRED ELECTRICAL SERVICES FOR AND REQUIRED ELECTRICAL CONNECTIONS TO ITEMS SHOWN ON THE DRAWINGS AND/OR SPECIFIED TO BE FURNISHED IN OTHER DIVISIONS OF SPECIFICATIONS OR BY OWNER SHALL BE ELECTRICALLY CONNECTED AS WORK OF THIS SECTION. ELECTRICAL WORK FOR EQUIPMENT SPECIFIED IN DIVISION 15- MECHANICAL SHALL BE AS SPECIFIED HEREINAFTER. RACEWAYS, GROUNDING CONNECTIONS, AND OTHER ROUGHING-IN INDICATED SHALL BE PROVIDED AS WORK OF THIS SECTION FOR DATA SYSTEM. MECHANICAL EQUIPMENT: ALL POWER WIRING ASSOCIATED WITH DIVISION 15, MECHANICAL SHALL BE PROVIDED AS WORK OF DIVISION 16, ELECTRICAL. ALL POWER DISCONNECT SWITCHES NOT PROVIDED WITH EQUIPMENT SHALL BE PROVIDED AS INDICATED UNDER DIVISION 16. EXCEPT AS MAY BE INDICATED ON THE DRAWINGS AND/OR HEREINAFTER NOTED, ALL CONTROL WIRING IS BY DIVISION 15. TESTS: TEST ALL WIRING TO INDICATE THAT THE COMPLETED SYSTEM IS FREE OF SHORT CIRCUITS AND UNDESIRABLE GROUNDS, AND IS READY FOR OPERATION. INSULATION RESISTANCE OF ALL WIRING SHALL MEET THE PERFORMANCE SUGGESTED BY THE MANUFACTURER. MAKE AN ACCEPTANCE TEST OF HIGH VOLTAGE CABLE AFTER TERMINATIONS TO INSURE APPROPRIATE CONNECTIONS. PROVIDE ALL NECESSARY TESTING EQUIPMENT FOR MAKING TESTS. ALL TESTS SHALL BE MADE IN THE PRESENCE OF THE OWNER OR THEIR QUALIFIED REPRESENTATIVE. WHEN TEST RESULTS ARE NOT SATISFACTORY, THE CONTRACTOR SHALL MAKE SUCH ADJUSTMENTS AND CHANGES AS ARE NECESSARY AND SHALL NOTIFY THE OWNER WHEN READY FOR ANOTHER TEST. REPEAT THE TEST OR TESTS WHICH DISCLOSED THE FAULTY OR DEFECTIVE WORK OR EQUIPMENT, AND MAKE SUCH ADDITIONAL TESTS AS NECESSARY TO PROVE CONFORMANCE. CHECK DIRECTION OF ROTATION OF ALL MOTORS AND REVERSE CONNECTIONS AS NECESSARY. CONTRACTOR SHALL NOT ATTEMPT TO "BUMP" MOTORS WHILE COUPLED TO MECHANICAL EQUIPMENT THAT COULD BE DAMAGED BY WRONG ROTATION. CERTIFICATES AND TEST REPORTS: SUBMIT REQUIRED COPIES OF ALL CERTIFICATIONS AND TEST REPORTS ADEQUATELY IN ADVANCE OF COMPLETION OF THE WORK TO ALLOW FOR REMEDIAL ACTION AS REQUIRED TO CORRECT DEFICIENCIES DISCOVERED IN EQUIPMENT AND SYSTEMS. E1.0 ELECTRICAL SPECIFICATIONS & DRAWING INDEX E1.1 TELE / DATA / VIDEO AND CCTV RISER DIAGRAMS E2.0 ELECTRICAL SITE PLAN EA1.0 APT BUILDING PANEL SCHEDULES AND 1-LINE EA2.0 APARTMENT ELECTRICAL POWER & LIGHTING FLOOR PLANS EA2.1 APARTMENT ELECTRICAL POWER & LIGHTING ATTIC / ROOF PLANS EA3.0 APARTMENT ELECTRICAL LOW VOLTAGE SYSTEMS FLOOR PLANS EA4.0 APARTMENT ENLARGED UNIT 1ST FLOOR ELECTRICAL PLANS EA4.1 APARTMENT ENLARGED UNIT 2ND & 3RD FLOOR ELECTRICAL PLANS EA4.2 APARTMENT ENLARGED UNIT 2ND & 3RD FLOOR ELECTRICAL PLANS ET1.0 TOWNHOME ENLARGED ELECTRICAL PLANS ELECTRICAL DRAWING INDEX WALL SWITCH 3-WAY WALL SWITCH WALL OCCUPANCY SENSOR SWITCH CEILING OCCUPANCY SENSOR, # DENOTES TYPE: G WP F M M S S OS __A ___ ELECTRICAL LEGEND F F S 3 SMOKE DETECTOR, 120V W/ BATTERY BACKUP CARBON MONOXIDE DETECTOR, 120V W/ BATTERY BACKUP HEAT DETECTOR PULL STATION SMOKE DETECTOR - ADDRESSABLE H S FIRE ALARM CONTROL PANEL DOOR ENTRY MASTER STATION F TELE / DATA MODEM LOCATION - SEE E1.2 FOR MORE INFO SMOKE/CARBON MONOXIDE DETECTOR, 120V W/ BATTERY BACKUP TELEVISION DB AREA OF REFUGE 2-WAY INTERCOM (M = MASTER) SECURITY CAMERA DVR AND POWER SUPPLY EQUIPMENT CONNECTION - SEE SCHEDULE (kW VALUE = DIRECT 208V CONNECTION TO HEATER) DOOR BELL ( INTERIOR CHIME ) WITH TRANSFORMER DOOR BELL ( EXTERIOR BUZZER ) SECURITY CAMERA, SEE CCTV RISER DIAGRAM ON E1.1 # DUPLEX WALL RECEPTACLE GFCI DUPLEX WALL RECEPTACLE GFCI DUPLEX WALL RECEPTACLE WITH WEATHERPROOF COVER QUAD DUPLEX WALL RECEPTACLE TELEPHONE / DATA JACK FIRE ALARM MANUAL PULL STATION FIRE ALARM HORN / STROBE FUTURE FIRE ALARM STROBE (PROVIDE BLANK PLATE) FIRE ALARM MONITOR MODULE FIRE ALARM CONTROL MODULE DISCONNECT SWITCH WITH AMPERAGE RATING (NF - NONFUSED, FU - FUSED) ELECTRICAL PANEL / SWITCHBOARD WITH DESIGNATION  ƒ9,(: 2 = NARROW LONG-RANGE VIEW DB AUDIO / VISUAL DOOR SIGNAL WITH TRANSFORMER ADDENDUM #2 9/15/14 A B C D E F G A B C D E F G 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 Architecture Planning Interior Design 217 North Aurora Street Ithaca NY 14850 p 607.273.7600 f 607.273.0475 DATE: PROJECT: OTHER: DRAWN BY:SS, BR A3ITHACA, NYSTONE QUARRY APARTMENTS, LLCSTONE QUARRY APARTMENTSREVISION SCHEDULE NAME DATE 18 JULY 2014 2012059 DEMCO NEW YORK CORP. DOHN A. SIMS, P.E. :DUQLQJLWLVDYLRODWLRQRIWKH1<6WDWH(GXFDWLRQ/DZ IRUDQ\SHUVRQWRDOWHUWKLVGRFXPHQWLQDQ\ZD\XQOHVV acting under the direction of a licensed professional engineer. If a document bearing the seal of an engineer is altered, the altering engineer shall affix to the document their seal and the notation "altered by" followed by their signature and the date of such alteration, and a specific description of the alteration. ELECTRICAL CONTRACTORS 6701 MANLIUS CENTER RD EAST SYRACUSE, NEW YORK 13057 E1.1 Tele/Data/Video and CCTV Riser Diagrams NOT TO SCALE NOT TO SCALE TV POWER CORD BY TENANT CORDLESS OR ANSWERING MACHINE POWER CORD BY TENANT INCOMING SERVICE WALL PLATE QUAD RECEPTACLE CABLE SPLITTER BY SERVICE PROVIDER (OPTIONAL) 4 PORT WIRELESS MODEM BY SERVICE PROVIDER MODEM POWER CORD BY SERVICE PROVIDER 5-WAY SPLIITER IN RECESSED WALL BOX WITH BLANK PLATE CABLING PROVIDED BY CONTRACT BEDROOM #1 BEDROOM #2 OR SPARE IN 1 BEDROOM UNITS BEDROOM #3 OR SPARE IN 1 OR 2 BEDROOM UNITS DOUBLE GANG BOX WITH DOUBLE GANG MUDRING SINGLE GANG BOX WITH SINGLE GANG MUDRING (TYP) TELEVISION BY TENANT STANDARD TELEPHONE* BY CONTRACT CABLING BY SERVICE PROVIDER OR TENANT TELEPHONE CABLE BY CONTRACT DOUBLE GANG BOX WITH SINGLE GANG MUDRING NOT TO SCALE TIME WARNER CABLE DEMARC AND RACK FLTG FIBER RACK FINGER LAKES TECHNOLOGY GROUP (FLTG) VERIZON DEMARC RACK VERIZON TELEPHONE TIME WARNER CABLE DEMARC DOOR EXIT DEVICE DOOR HARDWARE POWER SUPPLY120V ENTRANCE ACCESS CONTROL UNIT SOUTH LOBBY DOOR RELEASE 120V FIRE ALARM ( 2 LINES) RENTAL OFFICE ELEVATOR ( 2 LINES) 110 BLOCK PATCH PANEL 110 BLOCK PATCH PANEL PATCH CABLE BY SERVICE PROVIDER FIRST FLOOR SECOND FLOOR THIRD FLOOR RENTAL OFFICE 3 PORT WALL PLATE 1-VIDEO (F-TYPE) 1 DATA (RJ45) 1 TELEPHONE (RJ11) IN EACH APARTMENT (TYPICAL) SEE DETAIL 2 THIS DRAWING 5-WAY SPLITTER IN RECESSED BOX WITH BLANK WALL PLATE TV OUTLETS LOCATED DATA TELE VIDEO NSL RELAY CABINET CCTV DVR DISPLAY AND CAMERA POWER SUPPLIES (MECH B) "SIAMESE" POWER/SIGNAL CABLE PER CAMERA MANUFACTURER'S SPECIFICATIONS (TYPICAL) EX EX INDOOR FIXED CEILING MOUNTED CAMERAS (SEE FLOOR PLANS FOR LOCATIONS) POLE OR BUILDING MOUNTED OUTDOOR CAMERA (SEE SITE PLAN FOR LOCATIONS) APT BLDG MOUNTED OUTDOOR FIXED CAMERA (SEE FLOOR PLANS FOR LOCATION) S/S SURGE SUPPRESSION DEVICE (TYPICAL) -';'&016'5(14' 120V ADDENDUM #2 9/15/14 IN EACH APARTMENT SEE DETAIL 2 THIS DRAWING ELSEWHERE IN APARTMENT (TYPICAL) SEE DETAIL 2 THIS DRAWING 2-PORT PLATE 1 DATA (RJ45) 1 TELEPHONE (RJ11) FROM TIME WARNER CABLE DEMARC TO INCOMING SERVICE VIDEO JACK A B C D E F G A B C D E F G 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 Architecture Planning Interior Design 217 North Aurora Street Ithaca NY 14850 p 607.273.7600 f 607.273.0475 DATE: PROJECT: OTHER: DRAWN BY:SS, BR A3ITHACA, NYSTONE QUARRY APARTMENTS, LLCSTONE QUARRY APARTMENTSREVISION SCHEDULE NAME DATE 18 JULY 2014 2012059 DEMCO NEW YORK CORP. DOHN A. SIMS, P.E. :DUQLQJLWLVDYLRODWLRQRIWKH1<6WDWH(GXFDWLRQ/DZ IRUDQ\SHUVRQWRDOWHUWKLVGRFXPHQWLQDQ\ZD\XQOHVV acting under the direction of a licensed professional engineer. If a document bearing the seal of an engineer is altered, the altering engineer shall affix to the document their seal and the notation "altered by" followed by their signature and the date of such alteration, and a specific description of the alteration. ELECTRICAL CONTRACTORS 6701 MANLIUS CENTER RD EAST SYRACUSE, NEW YORK 13057 E2.0 1" = 20' N -';'&016'5(14')'0'4#.016'5 MDP-33 R EX EX EX MDP-33 R MDP-33 Q MDP-33 Q EX CCTVCCTVC C T V CCTV MDP-33 Q ADDENDUM #2 9/15/14 A B C D E F G A B C D E F G 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 Architecture Planning Interior Design 217 North Aurora Street Ithaca NY 14850 p 607.273.7600 f 607.273.0475 DATE: PROJECT: OTHER: DRAWN BY:SS, BR A3ITHACA, NYSTONE QUARRY APARTMENTS, LLCSTONE QUARRY APARTMENTSREVISION SCHEDULE NAME DATE 18 JULY 2014 2012059 DEMCO NEW YORK CORP. DOHN A. SIMS, P.E. :DUQLQJLWLVDYLRODWLRQRIWKH1<6WDWH(GXFDWLRQ/DZ IRUDQ\SHUVRQWRDOWHUWKLVGRFXPHQWLQDQ\ZD\XQOHVV acting under the direction of a licensed professional engineer. If a document bearing the seal of an engineer is altered, the altering engineer shall affix to the document their seal and the notation "altered by" followed by their signature and the date of such alteration, and a specific description of the alteration. ELECTRICAL CONTRACTORS 6701 MANLIUS CENTER RD EAST SYRACUSE, NEW YORK 13057 EA1.0 Apartment Building Panel Schedules and 1-Line NOT TO SCALE PANEL: MDP 400A, M.L.O.SURFACE MOUNTED LOC: ELEC M101 120 / 208V, 3PH, 4W BOTTOM FEED CKT. NO DESCRIPTION CONN VA LOAD WIRE SIZE BREAKER PHASE BREAKER WIRE SIZE CONN VA LOAD DESCRIPTION CKT. NOTRIPPOLEABCPOLETRIP 1 ELEVATOR 9,847 200A 3 X 3 150A 10,125 LAUNDRY SUB-PANEL 2 3 ELEVATOR 9,847 ----X ----10,125 LAUNDRY SUB-PANEL 4 5 ELEVATOR 9,847 ----X ----10,125 LAUNDRY SUB-PANEL 6 7 (SHUNT TRIP)------X 2 15A 1,000 STAIR S101 - HEATER: CUH-S1 8 9 1ST FLR - CORRIDOR LGTS 950 20A 1 X ----1,000 STAIR S101 - HEATER: CUH-S1 10 11 2ND FLR - CORRIDOR LGTS 570 20A 1 X 1 20A 500 DOOR ENTRY SYSTEM 12 13 3RD FLR - CORRIDOR LGTS 675 20A 1 X 1 20A 500 FACP 14 15 SPARE 20A 1 X 1 20A 500 AREA OF RESCUE INTERCOM 16 17 1ST FLR, EXTERIOR - RCPT 1080 20A 1 X 1 20A --TV, TELEBOARD - RCPT 18 19 2ND FLR, 3RD FLR, ROOF - RCPT 1080 20A 1 X 1 20A --TV, TELEBOARD - RCPT 20 21 2ND FLR DSS-A 950 15A 2 X 2 15A 1000 VESTIBULE - HEATER: CUH-L1 22 23 2ND FLR DSS-A 950 ----X ----1000 VESTIBULE - HEATER: CUH-L1 24 25 3RD FLR DSS-A 950 15A 2 X 2 15A 950 1ST FLR DSS-A 26 27 3RD FLR DSS-A 950 ----X ----950 1ST FLR DSS-A 28 29 MECH C, EXTERIOR - RCPT 540 20A 1 X 1 20A 1000 CCTV POWER SUPPLY 30 31 EXTERIOR - LGTS - BLDG MTD 104 20A 1 X 1 20A 500 DOOR CONTROLS 32 33 EXTERIOR - LGTS - SITE 532 20A 1 X SPACE 34 35 SPARE 20A 1 X SPACE 36 37 SPARE 20A 1 X SPACE 38 39 SPACE X SPACE 40 41 SPACE X SPACE 42 400A 120/208V ‘: MDP LP 400A ‘ HOUSE METER MAIN FUSED SWITCH EXISTING NYSEG UTILITY POLE MOUNTED TRANSFORMERS ALUMINUM SER CABLE (TYPICAL) 60A 120/ 208V ‘ TYPICAL APARTMENT UNIT LOADCENTER (4) 500 MCM ALUMINUM XHHW IN 4" CONDUIT (4) #2/0 AWG ALUMINUM XHHW (1) #4 AWG ALUMINUM XHHW GROUND IN 2" PVC UNDERSLAB PANEL: LP 225A, M.L.O.FLUSH MOUNTED LOC: LAUNDRY 100G 120 / 208V, 3PH, 4W BOTTOM FEED CKT. NO DESCRIPTION CONN VA LOAD WIRE SIZE BREAKER PHASE BREAKER WIRE SIZE CONN VA LOAD DESCRIPTION CKT. NOTRIPPOLEABCPOLETRIP 1 WASHER (STACKED)1,380 15A 1 X 1 15A 1,380 WASHER (STACKED)2 3 DRYER (STACKED)1,380 15A 1 X 1 15A 1,380 DRYER (STACKED)4 5 WASHER (STACKED)1,380 15A 1 X 1 15A 1,380 WASHER (STACKED)6 7 DRYER (STACKED)1,380 15A 1 X 1 15A 1,380 DRYER (STACKED)8 9 WASHER (STACKED)1,380 15A 1 X 1 15A 750 WASHER (SINGLE)10 11 DRYER (STACKED)1,380 15A 1 X 1 15A 864 DRYER (SINGLE)12 13 COMM'TY, LAUNDRY, OFFICE - LGTS 1,920 20A 1 X 1 20A SPARE 14 15 LAUNDRY, CORR, EXTERIOR - RCPT 1,080 20A 1 X 1 20A 300 ELEVATOR CAB.16 17 COMMUNITY RM - RCPT 720 20A 1 X 1 20A 300 ELEVATOR CAB.18 19 COMMUNITY RM - RCPT 720 20A 1 X 1 20A 300 ELEVATOR MACHINE RM.20 21 OFFICE - RCPT 720 20A 1 X 1 20A 300 ELEVATOR PIT 22 23 1ST FLR - FURNACE: FURN-B 1323 15A 1 X 1 15A 1,127 SUMP PUMP SP-A, 1/2 HP 24 25 ACC-2 3120 45A 2 X 1 20A SPARE 26 27 ACC-2 3120 ----X 1 20A SPARE 28 29 MECH A, TOILET - RCPT 720 20A 1 X 1 20A SPARE 30 31 DWH-A 15A 1 X SPACE 32 33 STAIR S100 - HEATER: CUH-S1 1000 15A 2 X SPACE 34 35 STAIR S100 - HEATER: CUH-S1 1000 ----X SPACE 36 37 RADON FANS RF-A(2)180 15A 1 X SPACE 38 39 ATTIC, WELL - LGTS 265 20A 1 X SPACE 40 41 EF-3 CORRIDORS (3)44 20A 1 X SPACE 42 ELECTRICAL EQUIPMENT CONNECTION SCHEDULE TAG DESCRIPTION VOLTAGE kW/HP CONNECTION TYPE NOTES EF-1 APARTMENT / TOWNHOME FULL BATH EXH FAN/LIGHT 120V 46.9 W DIRECT CONNECTION NOTE 1, 8 EF-2 APARTMENT / TOWNHOME HALF BATH EXH FAN/LIGHT 120V 46.9 W DIRECT CONNECTION NOTE 8 EF-3 COMMON SPACE EXHAUST FAN 120V 46.9 W DIRECT CONNECTION NOTE 4 FURN-A GAS FURNACE - APARTMENTS 120V 12 HP TOGGLE SWITCH AT UNIT FURN-B GAS FURNACE - 1ST FLOOR 120V 3 4 HP TOGGLE SWITCH AT UNIT ACC-1 AIR CONDITIONING CONDENSING UNIT - APARTMENTS 208V/1Ⱦ 2.5 kW 60A/2P PULLOUT DISCONNECT SWITCH, NEMA 3R ACC-2 AIR CONDITIONING CONDENSING UNIT - 1ST FLOOR 208V/1Ⱦ 5.47 kW 60A/2P PULLOUT DISCONNECT SWITCH, NEMA 3R DSS-A DUCT FREE SPLIT SYSTEM OUTDOOR UNIT AND CEILING PANEL 208V/1Ⱦ 1.9 kW 60A/2P PULLOUT DISCONNECT SWITCH, NEMA 3R TOGGLE SWITCH AT INDOOR UNIT NOTE 5 ELEV ELEVATOR CONTROLLER 208V/3Ⱦ 25 HP 200A/3P DISCONNECT SWITCH WITH AUX CONTACTS FUSED AT 125A NOTE 2 CUH ELECTRIC WALL HEATER 208V 2.0 kW DIRECT CONNECTION AD-1 AUTOMATIC DOOR OPENER 120V -DIRECT CONNECTION TO POWER UNIT ABOVE DOOR NOTE 3 DWH-A DOMESTIC WATER HEATER AND CIRCULATION PUMP 120V 520 Watts 1/6 HP TOGGLE SWITCH AT UNIT NOTE 6 HOOD KITCHEN RANGE HOOD 120V 36.3 W DIRECT CONNECTION SP-A ELEVATOR PIT SUMP PUMP 120V 1/2 HP DEDICATED SIMPLEX RECEPTACLE NOTE 7 RF-A RADON MITIGATION FANS 120V 89.9 W TOGGLE SWITCH AT UNIT NOTE 9 NOTES: 1.FAN TO RUN CONTINUOUSLY. CIRCUIT TO LIGHTING CIRCUIT VIA WALL-MOUNTED SWITCH TO INCREASE CFM UPON OCCUPANCY. 2.PROVIDE FUSED 15A/2P DISCONNECT SWITCH FOR ELEVATOR CAB LIGHTS AND FAN CIRCUIT. COORDINATE FUSE REQUIREMENTS WITH ELEVATOR SUPPLIER. 3.PROVIDE ROUGH-IN AS REQUIRED FOR HANDICAP DOOR CONTROLS. COORDINATE WITH DOOR SUPPLIER AND ARCHITECTURAL PLANS. 4.COORDINATE INSTALLATION WITH MECHANICAL CONTRACTOR. CONNECT TO LIGHTING CIRCUIT SERVING SPACE FAN IS LOCATED. 5.PROVIDE POWER AS REQUIRED TO CEILING PANELS, (1) PER DSS-A. COORDINATE INSTALLATION WITH MECHANICAL CONTRACTOR. 6.INTERLOCK CONTROL OF CIRCULATION PUMP WITH DWH-A AS NECESSARY. COORDINATE INSTALLATION WITH PLUMBING CONTRACTOR. 7.PROVIDE CIRCUIT/ RECEPTACLE FOR CONTROL PANEL IN ELEVATOR MACHINE ROOM. COORDINATE LOCATION WITH PLUMBING CONTRACTOR 8.SWITCH FAN AND LIGHT SEPARATELY. 9.COORDINATE INSTALLATION WITH MECHANICAL CONTRACTOR. PROVIDE WEATHERPROOF MEANS OF CONNECTION. 225A 120/208V ‘: PROVIDE SERVICE GROUNDING SYSTEM PER THE REQUIREMENTS OF NEC ARTICLE 250. ELEV F -';'&016'5(14'# (2) SETS OF (4) 750 MCM ALUMINUM XHHW IN 4" PVC UNDERGROUND 800A 120/208V ‘: (800A FUSES) (300A CIRCUIT BREAKER) ADDENDUM #2 9/15/14 DN UP 227J BATH. 227D BEDROOM 1 227H MECH 227F BEDROOM 2 225G BEDROOM 2 225J BEDROOM 1 228J BEDROOM 2 228G BEDROOM 1 228F MECH 226G BEDROOM 1 226E BATH. 226J BEDROOM 2 225F MECH 224E MECH 224D BATH.224F BEDROOM 223E MECH 223F BEDROOM 223D BATH. 222E MECH 200E ELEV. 222G BATH. 222K BEDROOM 2 222H BEDROOM 1 222A LIVING/DINING ROOM 222B KITCHEN 200S STAIR 223B KITCHEN 223A LIVING/DINING ROOM 224B KITCHEN 224A LIVING/DINING ROOM S200 STAIR 225B KITCHEN 225A LIVING/DINING ROOM 225D BATH. 226B KITCHEN 226A LIVING/DINING ROOM 227A LIVING/DINING ROOM 228B KITCHEN 228A LIVING/DINING ROOM 200T ST 228E BATH. 226L COR. 224J COR. 225L COR. 223J COR. 227L COR. 222M COR. 228L COR. 200R COR. 227B KITCHEN 2120 2219 200J JANITOR 200M ST K J H G F E D C B A K J H G F E D C B A UP 100C MECH C 118H BEDROOM 3 118G BATH. 118D TOILET 118N BEDROOM 1 118L BEDROOM 2 118K MECH 118B KITCHEN 118A LIVING ROOM 121J MECH 121K BATH. 121N TOILET 121B KITCHEN 121A LIVING ROOM 121C BEDROOM 1 121E BEDROOM 2 121G BEDROOM 3 117J BEDROOM 1 117E BATH.117G BEDROOM 2 117F MECH 100B MECH B 117B KITCHEN 117A LIVING ROOM 100L LOBBY VEST 100A MECH A 100D ELEVATOR MECH 100E ELEV. 100H COMMUNITY ROOM 100J TOILET 100S STAIR S100 STAIR 100F OFFICE 100G LAUNDRY 121M JANITOR 119G BATH. 119F MECH 119D BEDROOM 119A LIVING ROOM119B KITCHEN 120A LIVING ROOM 120D BEDROOM 120B KITCHEN 120G BATH. 120F MECH 100R COR. 119J COR. 118Q COR. 117L COR. 120J COR. 121Q COR.5'-11"5 1/2" 2120 2219 10'-0"22'-6"27'-0" 20'-6 1/2"6'-5 1/2" 59'-6" A B C D E F G A B C D E F G 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 Architecture Planning Interior Design 217 North Aurora Street Ithaca NY 14850 p 607.273.7600 f 607.273.0475 DATE: PROJECT: OTHER: DRAWN BY:SS, BR A3ITHACA, NYSTONE QUARRY APARTMENTS, LLCSTONE QUARRY APARTMENTSREVISION SCHEDULE NAME DATE 18 JULY 2014 2012059 DEMCO NEW YORK CORP. DOHN A. SIMS, P.E. :DUQLQJLWLVDYLRODWLRQRIWKH1<6WDWH(GXFDWLRQ/DZ IRUDQ\SHUVRQWRDOWHUWKLVGRFXPHQWLQDQ\ZD\XQOHVV acting under the direction of a licensed professional engineer. If a document bearing the seal of an engineer is altered, the altering engineer shall affix to the document their seal and the notation "altered by" followed by their signature and the date of such alteration, and a specific description of the alteration. ELECTRICAL CONTRACTORS 6701 MANLIUS CENTER RD EAST SYRACUSE, NEW YORK 13057 EA2.0 Apartment Electrical Power & Lighting Floor Plans 1/8" = 1'-0"1/8" = 1'-0" 22 N 22 GFI os 20 GFI 20 w os 21 21 21 31G 17 31 G 9S 20 W S os WP 17 GFI WP 29 GFI WP LP-15 GFI 31G 9 S os w w AC15 GFI 1,3 LDRY os 29 GFI EF-3 13 os 9 w os 9w S 17 GFI 17 19 19 MDP-19 11 S S os os 11C 11 S MDP-19 11S 11S 11 11 11 11 2 TYP 4/EA4.0 AP2 2/EA4.0 AP1 2/EA4.0 AP1 3/EA4.0 AP2 1/EA4.0 AP1 CUH 8/10 CCTV DE CUH 22/24 ARA DE FACP 21 DWH-A 31 SM 29 FURN-B23 S M 29 FF ELEV 3/EA4.2 AP1 2/EA4.1 AP1 4/EA4.2 AP1 2/EA4.2 AP1 3/EA4.1 AP1 3/EA4.1 AP1 1/EA4.1 AP1 29 29 MDP HOUSE METER APT MTRS MAIN SWITCH LP-15 9 9 9 DSS-A MDP-26/28 VIA ROOF UNIT 17 TYP 18 30 12 9 WP LP-15 GFI 9 CUH LP-33/35 13A 31G 9 19 16 12 9A1a AD-1 32 SP-A 24 13 W 13 W 1 19 17 17 13 29 -';'&016'5(14'# 17 16,18 MDP 1,3,5 AD-1 32 LP-15 13 V 5,7 9,11 2,4 6,8 10 12 N N 13A 13A 13A 13A 13A 13A 9A 9A1b 13A 13A 9A 9A 13 W 13 W 13 W TYP.6 9A 9A 9A 9A9A9A 2 22 11 A 11A 11A 11A 11A 11A 11A 11A 11A 11A1b 11A DSS-A MDP-21/23 VIA ROOF UNIT 11 9 9 11w 17 LP-15 )'0'4#.016'5 11w S os ADDENDUM #2 9/15/14 EF-3 LP-41 EF-3 LP-41 DN RS 2 A452 E8 2120 2219 22'-6"10'-0"15'-3 1/2"60'-11 7/8"16'-4"5'-11 1/4"10'-2 7/8"11'-3 3/8"11'-0"2120 2219 DN 334G BEDROOM 2 335J BEDROOM 2 335G BEDROOM 1 335F MECH 333G BEDROOM 1 333E BATH. 333J BEDROOM 2 331E MECH 331D BATH. 331F BEDROOM 330E MECH 330F BEDROOM 330D BATH. 329E MECH 300E ELEV. 329G BATH. 329K BEDROOM 2 329H BEDROOM 1 329A LIVING ROOM 329B KITCHEN 300S STAIR 330B KITCHEN 330A LIVING ROOM 331B KITCHEN 331A LIVING ROOM S300 STAIR 332B KITCHEN 332A LIVING ROOM 332E BATH. 333B KITCHEN 333A LIVING ROOM 335B KITCHEN 335A LIVING ROOM 332F BEDROOM 334J BEDROOM 1 300T ST 334B KITCHEN 334A LIVING ROOM 334E BATH. 334H CL 334F MECH 335E BATH. 329M COR. 335L COR. 334L COR. 330J COR. 331J COR. 333L COR. 300R COR. 332D MECH 333F MECH 300J JANITOR 300N ST K J H G F E D C B A K J H G F E D C B A A B C D E F G A B C D E F G 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 Architecture Planning Interior Design 217 North Aurora Street Ithaca NY 14850 p 607.273.7600 f 607.273.0475 DATE: PROJECT: OTHER: DRAWN BY:SS, BR A3ITHACA, NYSTONE QUARRY APARTMENTS, LLCSTONE QUARRY APARTMENTSREVISION SCHEDULE NAME DATE 18 JULY 2014 2012059 DEMCO NEW YORK CORP. DOHN A. SIMS, P.E. :DUQLQJLWLVDYLRODWLRQRIWKH1<6WDWH(GXFDWLRQ/DZ IRUDQ\SHUVRQWRDOWHUWKLVGRFXPHQWLQDQ\ZD\XQOHVV acting under the direction of a licensed professional engineer. If a document bearing the seal of an engineer is altered, the altering engineer shall affix to the document their seal and the notation "altered by" followed by their signature and the date of such alteration, and a specific description of the alteration. ELECTRICAL CONTRACTORS 6701 MANLIUS CENTER RD EAST SYRACUSE, NEW YORK 13057 EA2.1 Apartment Electrical Power & Lighting Attic / Roof Plans 1/8" = 1'-0" DSS-A DSS-A DSS-A LP-39 N LP-25/2760/2P 60/2P 60/2P 60/2P 60/2PACC -1 ACC -1 ACC -1 ACC -1 ACC -2 LP-39 N MDP-19 WP N 60/2P ACC -1 S W -';'&016'5(14'# LP-39 S TYP , MDP-19 WP MDP-26/28 MDP-25/27 MDP-21/23 1/8" = 1'-0" 3/EA4.2 AP1 2/EA4.1 AP1 4/EA4.1 AP1 1/EA4.2 AP1 3/EA4.1 AP1 3/EA4.1 AP1 1/EA4.1 AP1 13 S S os os 13 S 13S 13S 13 13 TYP LP-39 S N N MDP-19 S os MDP-19 13 13 2 TYP2 13 A 13A 13A 13A 13A 13A 13A 13A 13A 13A1b 13A DSS-A MDP-25/27 VIA ROOF UNIT 13 13w S os 13w RF-A LP-37 S MWP RF-A LP-37 S MWP 60/2PACC -1 60/2PACC -1 60/2PACC -1 60/2PACC -1 60/2PACC -1 60/2PACC -1 60/2PACC -1 60/2P 60/2P 60/2P 60/2P ACC -1 60/2P ACC -1 60/2P ACC -1 60/2P ACC -1 60/2P ACC -1 60/2P ACC -1 60/2P ACC -1 17 LP-15 LP-39 S LP-39 N )'0'4#.016'5 13C EF-3 LP-41 ADDENDUM #2 9/15/14 UP 100C MECH C 118H BEDROOM 3 118G BATH. 118D TOILET 118N BEDROOM 1 118L BEDROOM 2 118K MECH 118B KITCHEN 118A LIVING ROOM 121J MECH 121K BATH. 121N TOILET 121B KITCHEN 121A LIVING ROOM 121C BEDROOM 1 121E BEDROOM 2 121G BEDROOM 3 117J BEDROOM 1 117E BATH.117G BEDROOM 2 117F MECH 100B MECH B 117B KITCHEN 117A LIVING ROOM 100L LOBBY VEST 100A MECH A 100D ELEVATOR MECH 100E ELEV. 100H COMMUNITY ROOM 100J TOILET 100S STAIR S100 STAIR 100F OFFICE 100G LAUNDRY 121M JANITOR 119G BATH. 119F MECH 119D BEDROOM 119A LIVING ROOM119B KITCHEN 120A LIVING ROOM 120D BEDROOM 120B KITCHEN 120G BATH. 120F MECH 100R COR. 119J COR. 118Q COR. 117L COR. 120J COR. 121Q COR.5'-11"5 1/2" 2120 2219 10'-0"22'-6"27'-0" 20'-6 1/2"6'-5 1/2" 59'-6" DN UP 227J BATH. 227D BEDROOM 1 227H MECH 227F BEDROOM 2 225G BEDROOM 2 225J BEDROOM 1 228J BEDROOM 2 228G BEDROOM 1 228F MECH 226G BEDROOM 1 226E BATH. 226J BEDROOM 2 225F MECH 224E MECH 224D BATH.224F BEDROOM 223E MECH 223F BEDROOM 223D BATH. 222E MECH 200E ELEV. 222G BATH. 222K BEDROOM 2 222H BEDROOM 1 222A LIVING/DINING ROOM 222B KITCHEN 200S STAIR 223B KITCHEN 223A LIVING/DINING ROOM 224B KITCHEN 224A LIVING/DINING ROOM S200 STAIR 225B KITCHEN 225A LIVING/DINING ROOM 225D BATH. 226B KITCHEN 226A LIVING/DINING ROOM 227A LIVING/DINING ROOM 228B KITCHEN 228A LIVING/DINING ROOM 200T ST 228E BATH. 226L COR. 224J COR. 225L COR. 223J COR. 227L COR. 222M COR. 228L COR. 200R COR. 227B KITCHEN 200J JANITOR 200M ST K J H G F E D C B A K J H G F E D C B A K J H G F E D C B A DN 334G BEDROOM 2 335J BEDROOM 2 335G BEDROOM 1 335F MECH 333G BEDROOM 1 333E BATH. 333J BEDROOM 2 331E MECH 331D BATH. 331F BEDROOM 330E MECH 330F BEDROOM 330D BATH. 329E MECH 300E ELEV. 329G BATH. 329K BEDROOM 2 329H BEDROOM 1 329A LIVING ROOM 329B KITCHEN 300S STAIR 330B KITCHEN 330A LIVING ROOM 331B KITCHEN 331A LIVING ROOM S300 STAIR 332B KITCHEN 332A LIVING ROOM 332E BATH. 333B KITCHEN 333A LIVING ROOM 335B KITCHEN 335A LIVING ROOM 332F BEDROOM 334J BEDROOM 1 300T ST 334B KITCHEN 334A LIVING ROOM 334E BATH. 334H CL 334F MECH 335E BATH. 329M COR. 335L COR. 334L COR. 330J COR. 331J COR. 333L COR. 300R COR. 332D MECH 333F MECH 300J JANITOR 300N ST 2120 2219 A B C D E F G A B C D E F G 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 Architecture Planning Interior Design 217 North Aurora Street Ithaca NY 14850 p 607.273.7600 f 607.273.0475 DATE: PROJECT: OTHER: DRAWN BY:SS, BR A3ITHACA, NYSTONE QUARRY APARTMENTS, LLCSTONE QUARRY APARTMENTSREVISION SCHEDULE NAME DATE 18 JULY 2014 2012059 DEMCO NEW YORK CORP. DOHN A. SIMS, P.E. :DUQLQJLWLVDYLRODWLRQRIWKH1<6WDWH(GXFDWLRQ/DZ IRUDQ\SHUVRQWRDOWHUWKLVGRFXPHQWLQDQ\ZD\XQOHVV acting under the direction of a licensed professional engineer. If a document bearing the seal of an engineer is altered, the altering engineer shall affix to the document their seal and the notation "altered by" followed by their signature and the date of such alteration, and a specific description of the alteration. ELECTRICAL CONTRACTORS 6701 MANLIUS CENTER RD EAST SYRACUSE, NEW YORK 13057 EA3.0 Apartment Electrical Low Voltage Systems Floor Plans 1/8" = 1'-0"1/8" = 1'-0"1/8" = 1'-0" H S S S F S S H S H C C C C S S F DOORFACP S F S S S M M M M M M M M M F F F F F AORF S F S S F AORF S S S F S M F M M M F M M F F F M F M M F M M F M M M F M M F F F M F M M F M M M M WAP F F C AORSS 15cd EX )'0'4#.016'5-';'&016'5(14'# F F F F C F FAOR AORS F F S H F S F N N N F ADDENDUM #2 9/15/14 210 SF 117A LIVING ROOM 92 SF 117B KITCHEN 142 SF 117J BEDROOM 1 141 SF 117G BEDROOM 2 14 SF 117F MECH 13 SF 117H CL 80 SF 117E BATH. 26 SF 117D ST 15 SF 117C CL 13 SF 117K CL 64 SF 117L COR. 55 SF 118D TOILET 294 SF 118A LIVING ROOM 94 SF 118B KITCHEN 128 SF 118N BEDROOM 1 122 SF 118L BEDROOM 2 127 SF 118H BEDROOM 3 10 SF 118J CL 12 SF 118M CL 12 SF 118P CL 14 SF 118K MECH 65 SF 118G BATH. 38 SF 118F ST 25 SF 118C CL 74 SF 119B KITCHEN 210 SF 119A LIVING ROOM 14 SF 119H CL 59 SF 119G BATH. 14 SF 119F MECH 13 SF 119E CL 132 SF 119D BEDROOM26 SF 119J COR. 135 SF 121C BEDROOM 1 134 SF 121E BEDROOM 2 132 SF 121G BEDROOM 3 13 SF 121H CL 13 SF 121F CL 17 SF 121L ST 75 SF 121K BATH. 14 SF 121J MECH 43 SF 121N TOILET 14 SF 121P CL 87 SF 121B KITCHEN 215 SF 121A LIVING ROOM 106 SF 121Q COR. 12 SF 121D CL A B C D E F G A B C D E F G 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 Architecture Planning Interior Design 217 North Aurora Street Ithaca NY 14850 p 607.273.7600 f 607.273.0475 DATE: PROJECT: OTHER: DRAWN BY:SS, BR A3ITHACA, NYSTONE QUARRY APARTMENTS, LLCSTONE QUARRY APARTMENTSREVISION SCHEDULE NAME DATE 18 JULY 2014 2012059 DEMCO NEW YORK CORP. DOHN A. SIMS, P.E. :DUQLQJLWLVDYLRODWLRQRIWKH1<6WDWH(GXFDWLRQ/DZ IRUDQ\SHUVRQWRDOWHUWKLVGRFXPHQWLQDQ\ZD\XQOHVV acting under the direction of a licensed professional engineer. If a document bearing the seal of an engineer is altered, the altering engineer shall affix to the document their seal and the notation "altered by" followed by their signature and the date of such alteration, and a specific description of the alteration. ELECTRICAL CONTRACTORS 6701 MANLIUS CENTER RD EAST SYRACUSE, NEW YORK 13057 EA4.0 Apartment Enlarged Unit First Floor Electrical Plans 1/4" = 1'-0" UNIT 117 1/4" = 1'-0" UNITS 119, 120 1/4" = 1'-0" UNIT 118 1/4" = 1'-0" UNIT 121 12K12D 12 S 12B 11 12 12 12K 12E 14H 14 314B S 14 14 14 14B S 12 12 14 EF-1 13 12 C 12E AC 13 GFI 14 C FURN-A 10 S M 14 C FURN-A 10 S M 12H 3SS3 1212 14B 14 14 12 12 12 11 12D 12 B12 K12 K HOOD 12 1 12K12K 12 12 121112D 12 B 14 12E SS3 12 H 12 314 C FURN-A 10 S M 14 12 12 12B 1414 14 14 14B 1414 1414 14B 14 14 EF-2 15 EF-1 13 AC 13 GFI 13V 13V 13 V 14 14 14B S 14 14 14 C S FURN-A 10 S 14 14B 14 14 1414 14S 12 12 13 V AC 13 GFI SS EF-1 13 S 12C 12 H S 3 12D 12 12 11 12 12 EF-2 15 AC 15GFI S 12E 12K 12K S S S S S S S S EF-1 13 14B HOOD 12 1 HOOD 12 1 HOOD 121 )'0'4#.016'5 -';'&016'5(14'# 12 AC 9 AC 9 GFI AC 9 UC5 AC 7 AC 7 GFI +48" 7 AC 7 AP112 S 3 14 14 14 M M 14 AC 13 GFI F 12B 3M M 14 F M 14 S AP2 F 12 AC 9 GFI AC 9 UC 5 AC 9 AC 7 GFI AC 7 +48" 7 AP1 F 12 M ** * 14 AC 9 GFI +48" 7 AC 7 AC7 GFI AC 9 AC 9 UC 5 *** S 12 M M 12 14 M 14 F 12 H AC15 GFI AP2 +48" 7 AC 7 AC7 GFI AC 9 GFIAC 7 AC 9 +48"9 UC 5 14 14 14 14 S 14 14 14 S S 14 14 S 14 14 14 14 S S S N N N N S + ++ F **12 ADDENDUM #2 9/15/14 156 SF 222K BEDROOM 2 13 SF 222L CL 7 SF 222J CL 136 SF 222H BEDROOM 1 269 SF 222A LIVING ROOM 16 SF 222F CL 71 SF 222G BATH. 16 SF 222E MECH 28 SF 222D ST157 SF 222B KITCHEN 23 SF 222M COR. 236 SF 223A LIVING ROOM 27 SF 223J COR. 74 SF 223B KITCHEN 16 SF 223C CL 69 SF 223D BATH. 14 SF 223E MECH 11 SF 223G CL 143 SF 223F BEDROOM 14 SF 226C CL 23 SF 226D ST 64 SF 226E BATH. 12 SF 226K CL 153 SF 226J BEDROOM 2 139 SF 226G BEDROOM 1 11 SF 226H CL 231 SF 226A LIVING ROOM 93 SF 226B KITCHEN 54 SF 226L COR. 14 SF 226F MECH 5 SF 227M CL 18 SF 227C CL 12 SF 227E CL 245 SF 227A LIVING ROOM 86 SF 227B KITCHEN 47 SF 227L COR. 14 SF 227K ST 75 SF 227J BATH. 14 SF 227H MECH 10 SF 227G CL 136 SF 227F BEDROOM 2 149 SF 227D BEDROOM 1 A B C D E F G A B C D E F G 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 Architecture Planning Interior Design 217 North Aurora Street Ithaca NY 14850 p 607.273.7600 f 607.273.0475 DATE: PROJECT: OTHER: DRAWN BY:SS, BR A3ITHACA, NYSTONE QUARRY APARTMENTS, LLCSTONE QUARRY APARTMENTSREVISION SCHEDULE NAME DATE 18 JULY 2014 2012059 DEMCO NEW YORK CORP. DOHN A. SIMS, P.E. :DUQLQJLWLVDYLRODWLRQRIWKH1<6WDWH(GXFDWLRQ/DZ IRUDQ\SHUVRQWRDOWHUWKLVGRFXPHQWLQDQ\ZD\XQOHVV acting under the direction of a licensed professional engineer. If a document bearing the seal of an engineer is altered, the altering engineer shall affix to the document their seal and the notation "altered by" followed by their signature and the date of such alteration, and a specific description of the alteration. ELECTRICAL CONTRACTORS 6701 MANLIUS CENTER RD EAST SYRACUSE, NEW YORK 13057 EA4.1 Apartment Enlarged Unit 2nd & 3rd Floor Electrical Plans 1/4" = 1'-0" UNITS 222, 329 1/4" = 1'-0" UNITS 227, 334 1/4" = 1'-0" UNITS 223,224,330,331 1/4" = 1'-0" UNITS 226, 333 12 D 12B 12 12 12 11 S 12CS 12 E 12 C12K AC 9 GFI 12 K 12 S 3 12 H3S S S14B 14 14 12 14 14B 14 14 12 D 12 K 12 K 12E 314H 14 C FURN-A 10 EF-1 13 13V S 12C 12 12 12B 11 12 S S 14 14B 1212 14 14 14B 14 12 K12K 12 11 12 11 12D 12B 12E SS3 12H 14 14B 1212 14 14B 14 14 S S S 314 C FURN-A 10 S M S12C UC5 12K 12D 12 S S 3 12B 11 12 12 12 K 12 E 12H 314 B S 14 14 12 14 C FURN-A 10 S M S AC 13 GFI 13V FURN-A 10 S EF-1 13 S M HOOD 12 1 HOOD 12 1 HOOD 12 1 HOOD 12 1 )'0'4#.016'5 -';'&016'5(14'# M 14 14 AP1 AC 9 14 M 12 AP112 7 AC9 AC9 AC 9 UC5 AC 7 GFI +48" 7 AC 7 +48"7 AC 7 AC7 GFI AC 9 GFIAC 7 AC 9 AC 9 UC 5 S 14 14M M 14 14 14 AC 13 GFI F 14 14 14 14 M M 143 12 12 AP1 SS 11 UC 5 AC 9 AC 9 GFI AC 7 AC 7 GFI +48" 7 S 12 12 M 14 F AP1 AC 9 GFI AC 7 GFI AC 7 AC 7 GFI +48" 7AC 9 S 14 14 14 14 14 14 14 14 S 14 14 14 AC 9 N N NN AC 13 GFI 13 V EF-1 13 F S 13 V AC 13 GFI EF-1 13 F ADDENDUM #2 9/15/14 S 94 SF 225B KITCHEN 278 SF 225A LIVING ROOM 127 SF 225J BEDROOM 1 122 SF 225G BEDROOM 2 35 SF 225F MECH 40 SF 225E STORAGE 72 SF 225D BATH. 15 SF 225C CL 12 SF 225H CL 11 SF 225K CL 64 SF 225L COR. 74 SF 332B KITCHEN 249 SF 332A LIVING ROOM 71 SF 332E BATH. 159 SF 332F BEDROOM 26 SF 332G CL/ST 10 SF 332C CL 17 SF 332D MECH 15 SF 228F MECH 10 SF 228H CL 135 SF 228G BEDROOM 1 71 SF 228E BATH. 25 SF 228D ST 14 SF 228C CL 11 SF 228K CL 138 SF 228J BEDROOM 2 63 SF 228L COR. 85 SF 228B KITCHEN 241 SF 228A LIVING ROOM A B C D E F G A B C D E F G 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 Architecture Planning Interior Design 217 North Aurora Street Ithaca NY 14850 p 607.273.7600 f 607.273.0475 DATE: PROJECT: OTHER: DRAWN BY:SS, BR A3ITHACA, NYSTONE QUARRY APARTMENTS, LLCSTONE QUARRY APARTMENTSREVISION SCHEDULE NAME DATE 18 JULY 2014 2012059 DEMCO NEW YORK CORP. DOHN A. SIMS, P.E. :DUQLQJLWLVDYLRODWLRQRIWKH1<6WDWH(GXFDWLRQ/DZ IRUDQ\SHUVRQWRDOWHUWKLVGRFXPHQWLQDQ\ZD\XQOHVV acting under the direction of a licensed professional engineer. If a document bearing the seal of an engineer is altered, the altering engineer shall affix to the document their seal and the notation "altered by" followed by their signature and the date of such alteration, and a specific description of the alteration. ELECTRICAL CONTRACTORS 6701 MANLIUS CENTER RD EAST SYRACUSE, NEW YORK 13057 EA4.2 Apartment Enlarged Unit 2nd & 3rd Floor Electrical Plans 1/4" = 1'-0" UNIT 332 1/4" = 1'-0" UNIT 225 1/4" = 1'-0" UNITS 228, 335 AC 9 GFI UC 5 12 K12K 12 11 12 11 12D 12 B 12E SS3 12H 14 14 14B 1212 14 14 14B 14 EF-1 13 S S S AC 13 GFI 13V 312 C FURN-A 10 S M S12 C 14 AC 13 GFI 13V 14 14 14 S 14 14B 14 12D 11 12 12 12 B 12 CS 12E 33AC9 GFI AC 7 AC 9 12K 14C 12D 12B S 12E 3S 14 C 12 12 12H S 3 14B 14 S 14 14 14S 12 S EF-1 13 FURN-A 10S FURN-A 10S PANEL: TYPICAL APT LOAD CENTER 'AP1'60A, M.L.O.FLUSH MOUNTED LOC: UNIT ENTRY 120 / 208V, 1PH, 3W BOTTOM FEED CKT. NO DESCRIPTION CONN VA LOAD WIRE SIZE BREAKER PHASE BREAKER WIRE SIZE CONN VA LOAD DESCRIPTION CKT. NOTRIPPOLEABPOLETRIP 1 RANGE 1,800 20A 1 X --SPACE 2 3 SPACE ------X --SPACE 4 5 DISHWASHER 1,080 20A 1 X 2 20A 1,248 CONDENSING UNIT ACC-1 6 7 KITCHEN SMALL APPLIANCE 1 1,500 20A 1 X ""1,248 CONDENSING UNIT ACC-1 8 9 KITCHEN SMALL APPLIANCE 2 1,500 20A 1 X 1 15A 1,093 FURNACE FURN-A 10 11 DINING ROOM 20A*1 X 1 15A*GENERAL LIGHTING 1 12 13 BATHROOM 20A 1 X 1 15A*GENERAL LIGHTING 2 14 15 SPACE ------X ------SPACE 16 * = PROVIDE ARC-FAULT CIRCUIT INTERRUPTER BREAKER APARTMENT UNIT LOADCENTER SCHEDULES HOOD 121 HOOD 12 1 11 11 12 12 14 B 12 14 S 14 14 M M AP1 AC 7 GFI +48" 7 AP1 UC 5 12 K 12 11 )'0'4#.016'5 -';'&016'5(14'# M SS S 12 AP1 +48" 7 AC 9 AC 7 AC 7 AC 7 GFI AC 9 AC 9 F 14 M M 14 14 PANEL: TYPICAL APT LOAD CENTER 'AP2'60A, M.L.O.FLUSH MOUNTED LOC: UNIT ENTRY 120 / 208V, 1PH, 3W BOTTOM FEED CKT. NO DESCRIPTION CONN VA LOAD WIRE SIZE BREAKER PHASE BREAKER WIRE SIZE CONN VA LOAD DESCRIPTION CKT. NOTRIPPOLEABPOLETRIP 1 RANGE 1,800 20A 1 X --SPACE 2 3 SPACE ------X --SPACE 4 5 DISHWASHER 1,080 20A 1 X 2 20A 1,248 CONDENSING UNIT ACC-1 6 7 KITCHEN SMALL APPLIANCE 1 1,500 20A 1 X ""1,248 CONDENSING UNIT ACC-1 8 9 KITCHEN SMALL APPLIANCE 2 1,500 20A 1 X 1 15A 1,093 FURNACE FURN-A 10 11 DINING ROOM 20A*1 X 1 15A*GENERAL LIGHTING 1 12 13 BATHROOM 20A 1 X 1 15A*GENERAL LIGHTING 2 14 15 TOILET 20A 1 X ------SPACE 16 * = PROVIDE ARC-FAULT CIRCUIT INTERRUPTER BREAKER S 14 14 14 14 14 14 14 F 14 AC9 GFI AC 7 AC 9 12K HOOD 121 AC 7 GFI +48" 7 UC 5 12 K AC 9 AC 7 S N N N AC 13 GFI 13V EF-1 13 SS F S S ADDENDUM #2 9/15/14 41 SF 102D TOILET 334 SF 102C LIVING/DINING ROOM 40 SF 102S STAIR 57 SF 102E ST 11 SF 102A CL 25 SF 102B ENTRY 74 SF 102F KITCHEN 123 SF 202J BEDROOM 3 9 SF 202H CL 51 SF 202F BATH. 10 SF 202E CL 100 SF 202D BEDROOM 2 104 SF 202C BEDROOM 1 8 SF 202B CL 25 SF 202K MECH 48 SF 202A HALLWAY 64 SF 202S STAIR UPUP 102D TOILET 102F KITCHEN 102C LIVING/DINING ROOM 101A CL 101B ENTRY 101C LIVING/DINING ROOM101F KITCHEN 101D TOILET 103B ENTRY 103A CL 103D TOILET 103F KITCHEN 103C LIVING/DINING ROOM 104B ENTRY 104A CL 104D TOILET 104F KITCHEN 104C LIVING/DINING ROOM 105B ENTRY 105A CL 105D TOILET 105F KITCHEN 105C LIVING/DINING ROOM 106B ENTRY 106A CL 106D TOILET 106F KITCHEN 106C LIVING/DINING ROOM 107B ENTRY 107A CL 107D TOILET107E ST 107F KITCHEN 107C LIVING/DINING ROOM 108B ENTRY 108A CL 108D TOILET 108F KITCHEN 108C LIVING/DINING ROOM 107S STAIR 101S STAIR 101E ST 104E ST 104S STAIR 105E ST 105S STAIR 106E ST 106S STAIR 108E ST 108S STAIR 103S STAIR 103E ST 102S STAIR 102E ST A B C D E F G A B C D E F G 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 Architecture Planning Interior Design 217 North Aurora Street Ithaca NY 14850 p 607.273.7600 f 607.273.0475 DATE: PROJECT: OTHER: DRAWN BY:SS, BR A3ITHACA, NYSTONE QUARRY APARTMENTS, LLCSTONE QUARRY APARTMENTSREVISION SCHEDULE NAME DATE 18 JULY 2014 2012059 DEMCO NEW YORK CORP. DOHN A. SIMS, P.E. :DUQLQJLWLVDYLRODWLRQRIWKH1<6WDWH(GXFDWLRQ/DZ IRUDQ\SHUVRQWRDOWHUWKLVGRFXPHQWLQDQ\ZD\XQOHVV acting under the direction of a licensed professional engineer. If a document bearing the seal of an engineer is altered, the altering engineer shall affix to the document their seal and the notation "altered by" followed by their signature and the date of such alteration, and a specific description of the alteration. ELECTRICAL CONTRACTORS 6701 MANLIUS CENTER RD EAST SYRACUSE, NEW YORK 13057 ET1.0 Townhome Enlarged Unit 1st & 2nd Floor Electrical Plans 1/4" = 1'-0" UNITS 101, 102, 103, 104, 105, 106, 107, 108 1/4" = 1'-0" UNITS 101, 102, 103, 104, 105, 106, 107, 108 AC 4 GFI WP 11 11 P T S S 11 E 11 11 5 D 7 C S 3 12 AC 3 AC 3 GFI +48" 3 K AC5 AC 5 GFI 11 S S 9 9 9 9 S 7 7 7 7 7 C 7 H TOWNHOME FIRST FLOOR 1/8" = 1'-0" BUILDING 'A' SHOWN. BUILDING 'B' SIMILAR. PANEL: TOWN HOUSE PANEL 'THP'60A, M.L.O.FLUSH MOUNTED LOC:120 / 240V, 1PH, 3W BOTTOM FEED CKT. NO DESCRIPTION CONN VA LOAD WIRE SIZE BREAKER PHASE BREAKER WIRE SIZE CONN VA LOAD DESCRIPTION CKT. NOTRIPPOLEABPOLETRIP 1 DISHWASHER 1,080 20A 1 X 1 20A BATHROOM 1 2 3 APPLIANCE 1 1,500 20A 1 X 1 20A BATHROOM 2 4 5 APPLIANCE 2 1,500 20A*1 X 1 15A 1,093 FURNACE FURN-A 6 7 MASTER BEDROOM 15A*1 X 2 20A 1,380 CONDENSING UNIT ACC-1 8 9 BEDROOM 1, 2 15A*1 X ----1,380 CONDENSING UNIT ACC-1 10 11 1ST FLR GEN LIGHTING 15A*1 X 1 20A 1,800 RANGE 12 * = PROVIDE ARC-FAULT CIRCUIT INTERRUPTER BREAKER FURN-A 6 SM 300A/2P 120/240V ‘: MAIN FUSED SWITCH FROM NYSEG UTILITY POLE MOUNTED TRANSFORMERS (SEE SITE PLAN)60A 120/ 240V ‘ 3W TYPICAL TOWNHOME LOADCENTER 'THP' (3) 500MCM ALUMINUM XHHW IN 3" PVC EF-2 4 11 B 11 HOOD ACC-1 UC 1 SC THP DB S 9 S 9 9 7 S 9 EF-1 2 TH MTRS MAIN SWITCH THP THP TO NYSEG UTILITY POLE - MOUNTED TRANSFORMERS. SEE ONE-LINE ABOVE AND SITE PLAN. COORDINATE INSTALLATION WITH NYSEG. THP THP THP THP THP THP C TO UTILITY POLE AS DIRECTED BY SERVICE PROVIDER(S). SEE SITE PLAN AND RISER DIAGRAMS, SHEET E1.2. COORDINATE INSTALLATION WITH SERVICE PROVIDERS. ROUTE TOWNHOME FEEDERS UNDERSLAB IN PVC (TYPICAL). SEE TABLE ABOVE FOR SIZE. ROUTE TV/TELEPHONE CONDUITS BELOW SLAB (TYPICAL). PROVIDE SERVICE GROUNDING SYSTEM PER THE REQUIREMENTS OF NEC ARTICLE 250. -';'&016'5(14'6 )'0'4#.016'5 AC5 AC 3 11 11 11 E 8,10 9B B AC 2 GFI 7 7 B PROVIDE UNDER COMMON FACEPLATE (TYPICAL) 9 9 9 9 S 3,NL UNITS #101 & #106 ONLY N N N T TOWNHOME FEEDER SCHEDULE TAG SIZE(S)CONDUIT 3 #6 ALUM XHHW, # 8 ALUM XHHW GROUND 1" PVC 3 #4 ALUM XHHW, # 6 ALUM XHHW GROUND 1" PVC 3 #2 ALUM XHHW, # 4 ALUM XHHW GROUND 114" PVC 3 #1 ALUM XHHW, # 2 ALUM XHHW GROUND 114" PVC ADDENDUM #2 9/15/14 RECEPTACLE FOR RADON FAN (TYPICAL OF 2) T T TYPE 'T' FIXTURES (TYPICAL OF 8) T T T T T T T T ROUTE SO THAT DEMISING WALLS ARE NOT PENETRATED