Loading...
HomeMy WebLinkAboutKennedy Plumbing As-Builts 7-15-15A �� PLUMBING GENERAL NOTES ^ �-��/'/��x/��� A. DO NOT BASE ROUGH -IN DIMENSIONS ON INFORMATION SHOWN ON THE DRAWINGS. ROUGH -IN DIMENSIONS SHALL BE BASED ON ARCHITECTURAL INTERIOR PLANS, AND D1MENSIONED MILLWORK AND FIXTURE CATALOG CUTS. B. THIS CONTRACTOR SHALL PROVIDE ALL NECESSARY PIPING, CONNECTIONS, ACCESSORIES, SUPPORTS, HANGERS, ANCHORS. WIRING AND CONTROLS FOR COMPLETE AND FUNCTIONAL INSTALLATION OF ALL THE ITEMS PROVIDED. C. ALL FIXTURES AND EQUIPMENT SHALL BE INSTALLED IN STRICT CONFORMANCE WITH ALL APPLICABLE CODES AND MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS. D. THE PIPING LAYOUT SHOWN ON THIS DRAWING IS SCHEMATIC IN NATURE, IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO CAREFULLY COORDINATE IN ORDER TO AVOID INTERFERENCES WITH THE WORK OF ALL OTHER TRADES. THIS INCLUDES, BUT IS NOT LIMITED TO LIGHT FIXTURES, ACCESS HATCHES, HVAC DUCTWORK AND PIPING, ELECTRICAL CONDUITS, AND ARCHITECTURAL FEATURES. PROVIDE COORDINATION PRIOR TO THE FABRICATION OR INSTALLATION OF ANY WORK, E. ALL WORK SHALL BE PERFORMED IN COMPLIANCE WITH ALL LOCAL, STATE, AND FEDERAL CODES. THIS CONTRACTOR SHALL OBTAIN AND PAY FOR ALL REQUIRED PERMITS. F. ALL PENETRATIONS THROUGH OUTSIDE OR FOUNDATION WALLS SHALL BE SLEEVED WATERTIGHT. G. UNLESS OTHERWISE NOTED, PITCH ALL SANITARY PIPING ON THIS DRAWING AS FOLLOWS: PIPING 2" AND SMALLER PITCH AT1/4"PER FOOT. PIPING LARGER THAN 2^ PITCH AT 1/8" PER FOOT, H. ALL PENETRATIONS THROUGH FIRE RATED ASSEMBLIES SHALL BE FIRES1'OPPED. DUE TO THE SMALL SCALE OF THESE DRAWINGS IT IS NOT POSSIBLE TO SHOW ALL OFFSETS, FITTINGS, ETC.THE CONTRACTOR SHALL PROVIDE ALL OFFSETS, CONNECTIONS, FITTINGS, HANGERS, ANCHORS, SUPPORTS, WIRING, AND ACCESSORIES FOR A COMPLETE, COORDINATED AND OPERATIONAL INSTALLATION. J. FIELD VERIFY EXACT LOCATION, COMPOSITION AND CONDITION OF ALL SITE PIPING, VALVAND SYSTEMS AS REQUIRED FOR WORK OF THIS CONTRACT. K. ANY NECESSARY SHUTDOWNS WILL BE COORDINATED WITH OTHER TRADES. M. PROVIDE CUTTING, CORING AND PATCHING OF ALL WALLS, CEILINGS, SLABS AND DECKS AS REQUIRED FOR WORK SHOWN. COORDINATE ALL WORK WITH OWNER AND GENERAL CONTRACTOR. . AT COMPLETION OF WORK THESE DOCUME S SHALL BE MARKED UP TO PROVIDE RECORD DOCUMENTS FOR THE BUILDING OWNER AND/OR TENANT. ` 0. ALL HORIZONTAL RUNS OF RADON PIPING SHALL BE SLOPED TO DRAIN CONDENSATE BACK TO SUBDRAIN. ALL EXPOSED OR VIS1BLE INTERIOR RADON VENT PIPE SHALL BE IDENTIFIED WITH AT LEAST ONE LABEL THAT SHALL READ "SUB SLAB DEPRESSURIZATION SYSTEM DO NOT ALTER OR DISCONNECT". PLUMBING SrE~IF|C&T|OJS INCLUDED IN BID ARELABOR, MATERIALS, TOOLS, PLANT, TRANSPORTATION, EQUIPMENT, INSURANCE, TEMPORARY PROTECTION, PERMITS, TAXES, AND ALL NECESSARY AND RELATED ITEMS REQUIRED TO PROVIDE COMPLETE AND OPERATIONAL SYSTEMS SHOWN AND DESCRIBED. 2 P.C. SHALL PROVIDE ALL REQUIRED SUPPORTS, HANGERS, STRUCTURAL BRACES AND SUPPORTS, FIRE- STOPPING, FLASHING, SEALING AND PATCHING FOR ALL WORK SHOWN. P.C. SHALL SUPPORT ALL PIPING PER CODE REQUIREMENTS. 3 P.C. SHALL PROVIDE WORK IN COMPLIANCE WITH ALL NEW YORK STATE CODES, LOCAL CODES AND ORDINANCES, AND FEDERAL REGULATIONS. 4 P.C. SHALL PROVIDE ALL REQUIRED PERMITS AND INSPECTIONS. P,C. SHALL PROVIDE FIRE STOPPING FOR ALL PENETRATIONS THROUGH FLOORS, WA S AND ALL OTHER RELATED ASSEMBLIES. PROVIDE FIRE STOPPING SYSTEMS IN ACCORDANCE WITH ASTM E814. AT COMPLETION, P.C. SHALL PROVIDE OPERATIONS AND MAINTENANCE (0 & MI MANUALS FOR ALL EQUIPMENT PROVIDED. OWNER WILL RECEIVE ALL SHOP AND FABRICATION DRAWINGS GENERATED DURING CONSTRUCTION. 9 ALL DOMESTIC WATER PIPING DOWNSTREAM OF RPZ SHALL BE TYPE L COPPER TUBE WITH PRESSURE PATTERN FITTINGS AND LEAD-FREESOLDEROBCRIMPSTYLE (PROPRESS) CONNECTIONS, REFER TO FINAL APPROVED BACKFLOW PLAN FOR PIPE SIZES AND MATERIALS REGARDING PIPING UPSTREAM OF RPZ. 10 ALL STORM, SANITARY, AND VENT PIPING BELOW GROUND SHALL BE SERVICE WEIGHT CAST IRON PIPE WITH DWV PATTERN CAST IRON FITTINGS AND PUSH -JOINT BELL AND SP1GOT CONNECTIONS. ALL STORM, SANITARY, AND VENT PIPING ABOVE GROUND SHALL BE DWV PVC PIPE WITH DWV PATTERN PVC FITTINGS AND SOLVENT -WELDED CONNECTIONS. 11 BALL VALVES SHALL BE PROVIDED ON ALDOMESTIC WATER PIPING BRANCH MAINS. MAKE: WATTS FBV-3. SHUTOFF VALVES SHALL BE PROVIDED AT EVERY PLUMBING FIXTURE. 12 P.C. SHALL PROVIDE ACRYLIC WRAP AROUND PIPE LABELS (NOT ADHESIVE TYPE) FOR ALL PIPING AT 20'-0" INTERVALS. ALL LABELS SHALL HAVE DIRECTIONAL FLOW ARROWS AND SHALL BE INSTALLED ON BARE PIPE (WHEN PIPE IS NOT INSULATED) OR ON OUTSIDE OF INSULATED PIPING. MAKE: SETON, CALPICO OR EQUAL. PROVIDE LABELING FOR ALL PIPING INSTALLED ON PROJECT, ON 20'-0" CENTERS. 13 P.C. SHALL INSULATE ALL DOMESTIC HOT AND COLD WATER PIPING AND ALL CHILLED INDIRECT WASTE PIPING NOT CONCEALED IN INSULATED CAVITIES WITH 4 LB. DENSITY FIBERGLASS AND ALL SERVICE JACKETS. ALL INSULATION SHALL HAVE A FLAME SPREAD RATING OF 25 OR LESS AND A SMOKE DEVELOPED RATING OF 50. INSULATE ALL FiTTINGS, VALVE BODIES AND AROUND ALL HANGERS. 14 INSULATION THICKNESSES AS FOLLOWS: A. DOMESTIC COLD, 2" AND SMALLER 1/2"THICK, >2" 1" THICK B. DOMESTIC HOT WATER AND RECIRCULATION, 11/2^AND SMALLER I^THICK, /I1/Z^ 1 1/2" THICK C. HORIZONTAL STORM PIPING 1/2" THICK. D. ALL HOT WATER PIPING NOT IN PARTITIONS SHALL BE INSULATED TO AN R4 LEVEL 15 P.C. SHALL TEST ALL DOMESTIC WATER PIPING AT 125 PSI HYDROSTATIC FOR TWO HOURS. 16 P.C. SHALL TEST ALL SANITARY, WASTE, STORM, VENT, AND INDIRECT WASTE PIPING WITH 10 FEET OF HEAD OF WATER ABOVE HIGHEST POINT OF EACH SYSTEM. 17 NATURAL GAS PIPING SHALL BEA55T&C SCHEDULE 40 STEEL, WITH MATCHING MALLEABLE IRON FITTINGS. WHERE ROUTING PIPE HORIZONTALLY WOULD ENCOUNTER SIGNIFICANT AMOUNTS OF STRUCTURAL MEMBERS PIPING SHALL BE APPROPRIATELY SIZED AND PROPERLY INSTALLED CSST PIPING WITH MATCHING FITTINGS. 18 RADON PIPING UNDER SLAB SHALL BE CHARLOTTE PIPE AND FOUNDRY ASTM D 2729 DOUBLE PERFORATED PVC PIPE WITH MATCHING FITTINGS. RADON PIPING ABOVE SLAB SHALL BE CHARLOTTE PIPE AND FOUNDRY SCHEDULE 40 SOLID CORE DWV PVC WITH MATCHING FITTINGS. ALL JOINTS SHALL BE SOLVENT WELDED WITH LOW VOC CLEANER/PR1MER AND CEMENT. PERFORATED PIPE SHALL BE LAYED IN THE GRANUIAR FILL LAYER BELOW THE SLAB/GEOFOAM. REFER TO STRUCTURAL DRAWINGS FOR DETAILS AND SLAB SEALING PROCEDURES, PLUMBINGSCOPE AND MANUFACTURERS �|�TU������N'���� FIXTURE ��/��- ��»�-�~�� / ���v� A. MANUFACTURERS CATALOG NUMBERS ARE USED AS ILLUSTRATIONS. USE MANUFACTURERS AS INDICATED, UNLESS APPROVED BY OWNER. 2 INSTALLATION AND CARE A. MANUFACTURERS INSTRUCTION SHALL BE FOLLOWED IN PREPARING FOR THE FIXTURE INSTALLATION. ALL ROUGHING FOR EQUIPMENT, SINKS, ETC|STD8E CENTERED, B. SEAL FIXTURES IN CONTACT WITH WALLFLOORS AND COUNTERS USING A SANITARY TYPE, ONE PART MILDEW RESISTANT SILICONE CAULK. COLOR TO MATCH. C. ALL FIXTURES SHALL BE PROPERLY DRAINED, VENTED AND SUPPLIED WITH COLD AND/OR HOT WATER AS REQUIRED ACCORDING TO THE LOCAL CODE. D. AT COMPLETION OF WORK, CLEAN OUT ALL FIXTURES AND METAL WORK AND LEAVE IN POLISHED CONDITION. COORDINATE ALL PLUMBING FIXTURE MOUNTING HEIGHTS WITH ARCHITECTURAL INTERIOR ELEVATIONS. � .� �� � � �� DESIGNATION: PLUMBING FIXTURE AND EQUIPMENT SPECIFICATIONS MIN. COLD SIZE: MIN. HOT SUPPLY SIZE: MIN. VENT SIZE: MIN. DRAIN SIZE: BT -A COTG BATHTUB ADAPTABLE, CLARION BATHWAR#MP70lIUR)ONE'P1E[EFIBERGLASS TUB AND SHOWER ENCLOSURE, EQUIPPED WITH MOEN #8346 ADA COMPLIANT SHOWER FAUCET, HANDHELD SHOWER, FLEXIBLE HOSE, AND SLIDE BAR. ALL UNITS TO INCLUDE FACTORY INSTALLED REINFORCEMENT. SHOWER HEAD TO BE 1.75 GPM. CLEANOUT TO GRADE, CLEANOUT FITTING WITH 80 MINI -MANHOLE INSTALLED AT GRADE. DPCO DS -A DECK PLATE CLEANOUT, SIOUX CHIEF "FINISH LINE" 832 SERI ES WITH ROUND NICKEL BRONZE TOP. OVERFLOW DOWNSPOUT CLOSURE ASSEMBLY, ZURN #Z199 -DC. MOUNT AT 18" ABOVE FINISH GRADE. COORDINATE INSTALLATION WITH ARCHITECTURAL ELEMENTS. FD -A 1/2" 1/2" 1 1/2" 1 1/2" FLOOR DRAIN, SIOUX CHIEF "FINISH LINE' 832 SERIES WITH ROUND NICKEL BRONZE STRAINER. EQUIP EACH DRAiN WITH PROSET SYSTEMS # TG-34SC WATERLESS TRAP SEAL MAINTENANCE DEVICE, FD -B WOOD DECK FLOOR DRAIN, SIOUX CHIEF "HALO" 822 SERIES DRAIN WITH INTEGRAL FLASHING FLANGE AND WITH PROSET SYSTEMS # TG -345C WATERLESS TRAP SEAL MAINTENANCE DEVICE KS -A KITCHEN SINK - NON ADA ACCESSIBLE, ELKAY #LR3322-4 DOUBLE BOWL STAINLESS STEEL DROP-IN SINK EQUIPPED WITH ETERNITY #33384 FAUCET, BASKET STRAINER, CHROME PLATED SHUTOFF VALVES, CHROME PLATED SUPPLY RISER TUBES, END OUTLET WASTE, AND PVC P -TRAP ASSEMBLY. AERATOR TO BE 1.0 GPM. KS -B ?" 2" 4" 2" 2" KITCHEN SINK - ADA ACCESSIBLE, ELKAY #LR3322-4 DOUBLE BOWL STAINLESS STEEL DROP-IN SINK EQUIPPED WITH ETERNITY #33384 FAUCET, BASKET STRAINER, CHROME PLATED SHUTOFF VALVES, CHROME PLATED SUPPLY RISER TUBES, END OUTLET WASTE, PVC P -TRAP ASSEMBLY, AND TRAP INSULATION KIT. INSTALL PER ADA REQUIREMENTS. AERATOR TO BE 1.0 GPM. LAVATORY - NON ADA ACCESSIBLE, SOLID SURFACE TOP WITH INTEGRAL BOWL AND OVERFLOW (BY OTHERSEQUIPPED WITH CLEVELAND FAUCET #CA47711L FAUCET, POP-UP ASSEMBLY, CHROME PLATED SHUTOFF VALVES, CHROME PLAED SUPPLY RISER TUBES, AND PVC P -TRAP ASSEMBLY, AERATOR TO BE .5 GPM. 1/2" LAVATORY - ADA ACCESSIBLE, SOLID SURFACE TOP WITH INTEGRAL BOWL AND OVERFLOW (BY OTHERS) EQUIPPED WITH CLEVELAND FAUCET #CA47713L FAUCET, POP-UP ASSEMBLY, CHROME PLATED SHUTOFF VALVES, CHROME PLATED SUPPLY RISER TUBES, PVC P -TRAP ASSEMBLY, AND TRAP INSULATION KIT. INSTALL PER ADA REQUIREMENTS. AERATOR TO BE .5 GPM. LAVATORY - ADA ACCESSIBLE, SOLID SURFACE LAVATORY (BY OTHERS) EQUIPPED WITH CLEVELAND FAUCET #CA47713L FAUCET, POP-UP ASSEMBLY, CHROME PLATED SHUTOFF VALVES, CHROME PLATED SUPPLY RISER TUBES, PVC P -TRAP ASSEMBLY, AND TRAP INSULATION KIT. INSTALL PER ADA REQUIREMENTS. AERATOR TQBE.5GPM. IN -FLOOR LINT INTERCEPTOR, WATTS #LI -810. COORDINATE INSTALLATION WITH FINISH FLOOR MOP SERVICE S|NK.E.L. M USTEE #63 WITH CHICAGO FAUCETS #897 -RCF TWO HANDLE FAUCET, PAIL HOOK, MOP HANGER, EXTENSION HOSE, VINYL BUMPER GUARDS, AND STAINLESS STEEL WALL GUARDS. PRIMARY ROOF DRAIN, WATTS # RD -103 WITH INTEGRAL DOME STRAINER, FLANGE, ANOUNDERDE�K CLAMP. OVERFLOW ROOF DRAIN, WATTS #RD -103W WITH INTEGRAL 4" HIGH INTERNAL STANDPIPE AND INTEGRAL DOME STRAiNER. COORDINATE INSTALLATION WITH ROOFING CONTRACTOR. 1/2" 1 1/2" 1 1/2" 1 1/2" 1/2" 1/2" 1 1/2" 1 1/2" 1 1/2" 1/2" 1/2" | 1/2" 1 1/2" 3" � 3" ROOF HYDRANT, WOODFORD MANUFACTURING #SRH -MS FREEZELESS ROOF HYDRANT WITH INTEGRAL ROOF SUPPORT, AUTO DRAIN, AND DOUBLE CHECK VALVE. SHOWER - ADA ACCESSIBLE, CLARION BATHWARE #MP6333BF34 ONE-PIECE FIBERGLASS SHOWER ENCLOSURE WITH ADA -COMPLIANT SEAT, COLLAPSIBLE THRESHOLD, AND GRAB BARS, EQUIPPED WITH MOEN #8346 ADA COMPLIANT SHOWER FAUCET, HANDHELD SHOWER, FLEXIBLE HOSE, AND SLIDE BAR. INSTALL PER ADA GUIDELINES. SHOWERHEAD TO BE 1.75 GPM. 1/2" 1/2" 3" 2" WC-AWATER CLOSET NON ADA ACCESSIBLE, MANSFIELD "ALTO" (BOWL #4130, TANK #31211 ROUND BOWL 1.28 GPF VITREOUS CHINA TOILET WITH SEAT & COVER, CHROME SHUTOFF VALVE, CHROME SUPPLY RISER TUBE, WAX RING, AND BOLT SET. WATER CLOSET ADA ACCESSIBLEMANSFIELD "ALTO^(BOWL 44l37.TANK #3121) ADA -COMPLIANT HEIGHT ELONGATED BOWL 1,28 GPF VITREOUS CHINA TOILET WITH SEAT & COVER, CHROME SHUTOFF VALVE, CHROME SUPPLY RISER TUBE, WAX RING, AND BOLT SET. WALL HYDRANT, WOODFORD MANUFACTURING MODEL#65C AUTOMATIC DRAINING FREEZELG5SWALL HYDRANT WITH LOOSE KEY STYLEO0NTROL WASHING MACHINE FITTING, SIOUX CHIEF "OX-BOX'696 SERIES WITH DUAL SHUTOFF VALVES, 3/4" MALE HOSE OUTLETS, AND 2" WASTE RECEPTOR. Tag DWH-A anu Lochinvar acture RA RndonAwoy RF -A Fantech RVC R E Williams SP -A ST -A iberty Pumps, I chinvar GS6-40-YBPDT 1/2" 1/2" 3/4" ?" 3" 2" 3" 2" J^ 1/2" 1/2" 2" PLUMBING EQUIPMENT SCHEDULE Description 2" Armor WaR Mounted Waterr Heate(x2l. Units supplied as packaged system including all circulation pumps and controls. Circulation Pumbe rated. 40 gallon direcvent, sealed combustion watr heater. Radon Pressure Alarm. Calibrated to trip at less than .25 InWc vacuum. 2 001-2 HPl90 GRRC-40 nc ELVZ80 |RJS80 Vertical Inline Radon Ventilation Fan. I20mA[.1Q.89,9Watts. Schedule 40 PVC Radon Vent Cap. Point to match roof finish color. 1/2 HP Submersible sump pump with integral oil monitoring and alarming system. Vertical Round Jacketed Gloss Lined Tanks TMuA Powers XT -A Amtrol LEMM4J21 HYDROGUARD XP Hi/La Master Tempering Valve Thermal expansion tank for domestic hot water system PIPE ACCESSORY SCHEDULE Tag Manufacturer Model Size Description DCDA WATTS 757DCDA'8FG 4" Double Check Detector Backfiow Assembly DCVA WATTS Lp007'0SY 2.5" UDouble Check Valve RockUnovAasemNy 5010 1"|Hydratrol - water hammer arrester Jay R. Smith 1WM-2 BADGER 55 WATER METER STRAINER, AS PRESCRIBED BY WATER PURVEYOR MUNICIPAL WATER mETER.ASPR[S�R|8EDBYVVATERPURVEYQR PRIVATE WATER METER TO BE READ BY OWNER TO RECORD TOWNHOUSE BUILDING WATER CONSUMPTION VISUAL FIDELITY NOTE: THIS DRAWING SET CONTAINS COLO ��| ����[��JT�� TO /-��KJ\/��\/ v/^/c�r��- / /���-u / / �~��c-�����_�/ �_�-�_'��-/w /.� �~��/*v�-, DESIGN INTENT AND TO EASE INTERPRETATION. IF THIS DRAWINGS SET IS RECEIVED IN MONOCHROME ORGAYSCAE EASE CONTACT KE0NEDY MECHANICAL INC. AT THE NUMBER LISTED TO THE RIGHT FOR A COLOR PRINTED SET. 10 UNETYPELEGEND SYMBOL DESCRIPTION ' ---- COLD WATER PIPING ICI ------ HOT WATER PIPING (H) ------ HOT WATER RETURN PIPING IHWR( os-~- VE NT PIPING IV) ______ SANITARY OR WASTE PIPING (SAN or W) -----' COMBINATION SEWER PIPING ICOMBI ID OVERFLOW STORM PIPING (OF) - RADON VENT PIPING (RADON) ------- NATU RAL GAS P1 PING IG) - - -- INDIRECT WASTE PIPING (IW) CHECK VALVE DIRECTION OF FLOW NTS ------ EXISTING PIPING --- --' PIPING TO BE REMOVED P|PIyJG SYMBOLS SYMBOL DESCRIPTION 0— s- ELBOW UP, ELBOW DOWN AFF DROP CONNECTION (E) -+v-- Li._ DOWN ' P -TRAP os-~- U [LG4NOVTICV| H CAP DRPLUG Hi- UNION ID FLOOR DRAIN (FD) HB HOSEBUBR H GENERAL CONTRACTOR SHUT OFF VALVE LAVATORY CHECK VALVE ABBREVIATIONS AND TAGS SYMBOL DESCRIPTION AFF ABOVE FINISHED FLOOR (E) EXISTING EC ELECTRICAL CONTRACTOR ERL EXISTING TO RELOCATE ETR EXISTING TO REMAIN FD FLOOR DRAIN FPC FIRE PROTECTION CONTRACTOR FS FLOOR SINK GC GENERAL CONTRACTOR LAV LAVATORY MC MECHANICAL CONTRACTOR NTS NOT TO SCALE PC PLUMBING CONTRACTOR SK SINK VTR VENT THROUGH ROOF WC WATER CLOSET WPCO WALL PLATE CLEANOUT REMOVAL KEYNOTE \ � INSTALLATION KEYNOTE POINT8FS[ONmE[T|Om ^� �"DISCONNECTION __ P0NTOFCONNECTION RICTO-RD DRAW- 7.-6 To Be Used For Recording Field De,vXmfio}s And "�~1 �� �� ��,�� "m� ���1�� ������/ �� 'f��' �� ~ ����j,��� Correct DA TE 10 � ��. ��r��nn Ke Planning Interior Design ^^ ^~^~^ `=~^ 217 North Aurora Street Ithaca NY 14850 p 607.273.7600 f 607.273.0475 MECHANICAL CONTRACTORS ~^v°".w"^o~°,.wn',."r~nn,=no~ // COMFORT 5/REtT 585-232-26500 THESE DDCUMFNO AND ALL IDEAS., A$JANGFNANT. DESIGNS AND PLANS INL>ICAmr) UIEF,EOW ON rREsmcorEIEREbY ARE OWNED AND REMAIN nE FROPEATYOF JENNEDY MECSA,NICAS INC. ARE) NO FART rrtELmnrSHALL. E,E.UTILIZED By. ANY F'ERew,,/xw'OR. CORPORATION FOR. ANY PURPOSE W1IAT5OEV,EN EXCEPT wnnrnsarEonCWRITTEN PERMISSION nrKENNEDY M.ECHANICAL INC. ALL RIGhTS RESERVED • inner Mechanical Design Services c2,...2723 Panotama 22,0, Buiiding 2. 221 C.i Rochester.. NY"1 462.5 555-31 9 WARNING: It is a violation of New York State Law for any person, unless acting under the direction of a licensed Architect, to alter this document in any way. If a document bearing the seal of an Architect is altered, the altering Architect shall affix to such document his seal and the notation "altered by" followed by his signature, the date of such alteration, and a specific description of the alteration. REVISION SCHEDULE NAME DATE OWNER CHANGES STONE QUARRY APARTMENTS 15 AUG 2014 11 SEP 2014 RTMENTS, LL STONE QUARRY 0 u� DATE: 7/18/2014 2012059 OTHER: DRAWN BY: TB PLUMBING - GENERAL NOTES LEGEND, , SCHEDULES Pool A 5 6 7 8 9 10 Ca -A 3"SAN v LI -A 24) ci., APARTMENT BLDG. FOUNDATION PLAN - PLUMBING ° •' 1/8" = 1'-0" FOUNDATION PLAN DRAWING NOTES 1 4" SANITARY TO SITE. REFER TO CIVIL PLANS FOR CONTINUATION. COORDINATE INVERT WITH FOUNDATION COMPONENTS AND INVERT INDICATED ON CIVIL DRAWINGS. 2 3/4" C TO SITE. SEE CIVIL PLANS FOR CONTINUATION, 3 CAP END OF PERFORATED RADON PIPING (TYPICAL). 4 ALL HORIZONTAL RADON PIPING BELOW SLAB SHALL HAVE PERFORATIONS FACING DOWN. 5 4" RADON VENT UP. ALL VERTICAL RADON VENT PIPE SHALL BE WITHOUT PERFORATIONS. 6 GAS RISER UP. MAINTAIN LINE SIZE INDICATED (TYPICAL). 7 1 1/4" G UP TO METER. COORDINATE RISER LOCATION WITH FUEL GAS SUPPLIER, SITE CONTRACTOR, AND ALL APPLICABLE TRADES. 8 1" G UP TO METER. COORDINATE RISER LOCATION WITH FUEL GAS SUPPLIER, SITE CONTRACTOR, AND ALL APPLICABLE TRADES 9 3/4" G UP TO METER. COORDINATE RISER LOCATION WITH FUEL GAS SUPPLIER, SITE CONTRACTOR, AND ALL APPLICABLE TRADES. 10 3" SANITARY UP. 11 2" SANITARY UP. 12 3/4" C UP, COORDINATE RISER LOCATION AS NOTED ON P101, NOTE 36. 13 2" SANITARY UP. 14 4" SANITARY UP TO DECK PLATE CLEANOUT OR CLEANOUT TO GRADE. 15 4" SANITARY UP. 16 3" SANITARY UP. 17 2" SANITARY WITH P -TRAP UP 18 2" VENT UP. 19 2" SANITARY WITH P -TRAP UP TO FLOOR DRAIN. 20 ROLL SANITARY SEWER DOWN WITH 45° ELBOWS SO PIPE DOWNSTREAM OF THIS POINT SHALL BE UNDER GEOFOAM FILL. COORDINATE WITH STRUCTURAL DRAWINGS. 21 ALL PIPING IN GRAY DIAGONALLY HATCHED AREA (EXCEPT LAUNDRY ROOM PIPING) SHALL BE INSTALLED UNDER GEOFOAM FILL. REFER TO STRUCTURAL DRAWINGS FOR DEPTH AND CONFIGURATION. COORDINATE WITH GEOFOAM CONTRACTOR TO AVOID RISER DISTURBANCE. 22 4" STORM UP. 23 3" SANITARY WITH P -TRAP UP TO MOP SERVICE SINK. 24 4" SANITARY WITH P -TRAP UP TO FLOOR DRAIN. 25 3" SANITARY UP TO LAUNDRY CONNECTIONS. 26 PIPING AND LINT INTERCEPTOR FROM THIS POINT UPSTREAM SHALL BE ON TOP OF GEOFOAM. REFER TO STRUCTURAL DRAWINGS. COORDINATE PIPING AND LINT INTERCEPTOR INSTALLATION WITH GEOFOAM CONTRACTOR. 27 2"C UP. 28 3" W UP (DOMESTIC WATER SERVICE). 29 4" W UP (FIRE SERVICE). 30 2" C TO SITE. REFER TO CIVIL DRAWINGS FOR CONTINUATION. 31 3" W TO SITE. REFER TO CIVIL PLANS FOR CONTINUATION. 32 4" W TO SITE. REFER TO CIVIL PLANS FOR CONTINUATION. 33 4" STORM TO SITE. REFER TO CIVIL PLANS FOR CONTINUATION. 34 4" SANITARY UP TO WALL PLATE CLEANOUT. 35 6" FRESH AIR VENT FOR REQUIRED HOUSE TRAP. REFER TO CIVIL DRAWING C201, DETAIL 7 FOR REQUIREMENTS. NOTE: ALL STORM, SANITARY, AND VENT STACKS SHALL HAVE A TWO-WAY CLEANOUT TEE INSTALLED AT THE BASE OF THE STACK (12" AFF TO CL OF TEE) PER THE PLUMBING CODE OF NEW YORK STATE, WHICH WILL ACT AS A STACK CLEANOUT AND AS A CHANGE OF DIRECTION CLEANOUT FOR PIPING UP TO 40' DOWNSTREAM. SANITARY SEWER TO HAVE CLEANOUT AT CONNECTION TO SITE SEWER AS PART OF REQUIRED HOUSE TRAPS. REFER TO SITE WINGS FOR DETAIL. / /NOTE; REFER TO P100A FOR TOWNHOME ,BUILDING RADON PIPING BELOW SLAB / i / NOTE: RADON MITIGATION SYSTEM TO BE INSTALLED AT UNITS INDICATED ON P100A. . TYPICAL TOWNHOME FOUNDATION PLAN - PLUMBING 118" = 1/4"G H0LTARCHITE TS Architecture Planning Interior Design 217 North Aurora Street Ithaca NY 14850 p 607.273.7600 f 607.273.0475 KENNEDY MECHANICAL CONTRACTORS iA T ING & FERE PROTECTION II COMFORT 51REET ROC/ 1E5TER, NEW YORK 14620 585-232-2800 TNFSF DOCUMENTS AND ALL IDEAS, AR5.ANGEMENT, DESIGNS AND PIAN5 INDICATED THEREON OR PRESENTED THEREBY ARE OWNED AND REMAIN THE PROPERTY OF RE'NNEDY MECHANICAL INC. AND NO PART THEREOF' .SHALL OF UTILIZED BY ANY PERSON, FIRM. OR CORPORATION FOR ANY PURPOSE WHATSOEVER EXCEPT WITH THE SPECIFIC WRTTEN 9'ERME55ION Of' F,ENNEDY MECHANICAL INC. AS. RJGHTS RESERVED 62 E,u cing ;fYEF F1F Nit' "1C WARNING: It is a violation of New York State Law for any person, unless acting under the direction of a licensed Architect, to alter this document in any way. If a document bearing the seal of an Architect is altered, the altering. Architect shall affix to such document his seal and the notation "altered by" followed by his signature, the date of such alteration, and a specific description of the alteration. REVISION SCHEDULE NAME DATE 15 AUG 2014 STONE QUARRY APARTMENT STONE QUARRY AP z p U DATE: 7/18/20 4 PROJECT; 2012059 OTHER: DRAWN BY: JTB APARTMENT BLDG.ITH FOUNDATION PLANS - PLUMBING P100 A 2 4 7 8 9 10 2015 2:04:08 PM 2 4 5 6 7 8 9 10 NOTE: REFER TO P101, P102, P103 FOR RADON SYSTEM RISER CONTINUATION. EACH RISER SHALL BE ROUTED THROUGH THE UNIT ABOVE IT AS INDICATED ON THE PARTIAL TOWNHOME FLOOR PLANS. THE SYSTEMS AS INDICATED ARE TYPICAL OF BOTH TOWNHOME BUILDINGS. 4 LADON r1 N.r I^.T. i...,.. q F r r�i 4"RADON TOWNHOME FOUNDATION PLAN - RADON PIPING 3/16" = 11-0" TOWNHOME FOUNDATION PLAN RADON SYSTEM DRAWING NOTES 1 CAP END OF PERFORATED RADON PIPING (TYPICAL). 2 ALL HORIZONTAL RADON PIPING BELOW SLAB SHALL HAVE PERFORATIONS FACING DOWN, 3 4" RADON VENT UP. ALL VERTICAL RADON VENT PIPE SHALL BE WITHOUT PERFORATIONS, %u' HOLTARCHITECTS Architecture Planning Interior Design 217 North Aurora Street Ithaca NY 14850 p 607.273.7600 f 607.273.0475 KENNEDY HANICAL CONTRACTORS P1.DMA1NG HEATING. FIRE PIOTECIION c©MF©Rr.5 rREeT R©cl115TER, NNW YORK 14620 585-232-2800 THEOR DOCUMENTS AND ALL IDEAS. ARRANGEMENT. DESIGNS AND PIANS INDICATED THEREON OR PRESENTED THEREBY ARE OWNED AND REMAIN ThE ROPFRTY OF KENNEDY MECHANICAL INC. AND NO PART i1EKEOF SHAH_ BE UTILIZED BY ANY PERSON, FIRM. OR ORPORAT1ON FOR ANY PURPOSE WHATSOEVER EXCEPT WITh THE SPECIFIC WRITTEN PERMISSION OF KENNEDY MECHANICAL INC. ALL RIGHTS RESERVED Baum sl vwgrSerVices [BEI;LLIE q". JILLIL1L, 210 WARNING: It is a violation of New York State Law for any person, unless acting under the direction of a licensed Architect, to alter this document in any way. If a document bearing the seal of an Architect is altered, the altering Architect shall affix to such document his seal and the notation "altered by" followed by his signature, the date of such alteration, and a specific description of the alteration. REVISION SCHEDULE NAME DATE 15 AUG 2014 STONE QUARRY APARTMENTS J J APARTMENTS w z 0 F -- ITHACA. NY DATE: 7/18/2014 PROJECT: 2012059 OTHER: DRAWN BY: JTB D G B TOWNHOME BUILDING FOUNDATION A PLAN - RADON LAYOUT P10OA 7/14/2015 2:04:17 PM 1 2 4 5 6 7 8 9 10 G 0 WH 1/8"= 11-0" ..._ _.-_. T ---._PLUMBING ,rte APARTMENT BLDG. FIRST FLOOR PLAN - PL • KS -B 1 112"SA 2 000 KS -A DECD ST -A v_C WC B EDA DSA 0 F WC -A 2 -SAN SH -B 2 -SAN 1/2"G TV 2' P 2 A LAV LAV -A -A WC -A .� TV SAN V -+v LAV -B 0- COTG XT -A LAVA Tl CV -A 0 2"SAN-mss SAN 1"G W COT 4 2 /4' 2"G 3/4-C 1"G MSS -A 11/2"G /4"C 2 3/4"G AV G 3/4"C 1112 D -A LAV -B 2 -SAN 11/ DPCQ-.. 2 314"C 4.5 0 KS - 17/2"SAN .G LI -- Wt.) ill"G C -A /4" G 7 WC -B 4 WH -A 2 -SAN SH -A TSAR KS-AA� D -A D -A V-A 11/2 SAN 11/2 -SAN 0• A 3!4" G FD -A 00 A GAS METER UTILITY cal 2 FIRST FLOOR PLAN DRAWING NOTES 1/2" G DOWN TO RANGE. 3/4" G UP. PROVIDE SHUTOFF VALVE (TIGHT TO WALL), UNION, DIRT LEG, AND FINAL CONNECTION POINT FOR APPLIANCE. COORDINATE LOCATION AND TERMINATION WITH APPLIANCE MANUFACTURER, MILLWORK DRAWINGS, AND BUILDING OWNER. RANGE MUST BE ABLE TO SIT FLUSH WITH REAR WALL WHEN INSTALLED. 3/4" 0 UR 1/2"G UP. 4 DROP 1/2" G TO FURNACE. PROVIDE SHUTOFF VALVE, UNION, DIRT LEG, AND FINAL CONNECTION TO APPLIANCE IN ACCORDANCE WITH ALL FUEL GAS CODES AND REGULATIONS. 5 1/2" G DOWN TO RANGE. PROVIDE SHUTOFF VALVE (TIGHT TO WALL), UNION, DIRT LEG, AND FINAL CONNECTION POINT FOR APPLIANCE. COORDINATE LOCATION AND TERMINATION WITH APPLIANCE MANUFACTURER, MILLWORK DRAWINGS, AND BUILDING OWNER. RANGE MUST BE ABLE TO SIT FLUSH WITH REAR WALL WHEN INSTALLED. 6 2 1/2" G DOWN IN WALL CAVITY. COORDINATE PENETRATION HEIGHT THROUGH EXTERIOR WALL WITH GAS UTILITY COMPANY. PROVIDE MAIN SHUTOFF VALVE AND FINAL CONNECTION TO METER. 9 10 11 12 13 14 16 17 18 19 20 1/2" G DOWN TO FURNACE. 3/4" G UP. PROVIDE SHUTOFF VALVE, UNION, DIRT LEG, AND FINAL CONNECTION TO APPLIANCE IN ACCORDANCE WITH ALL FUEL GAS CODES AND REGULATIONS. 3"' WASTE STACK VENT LIP, 3" WASTE STACK VE' ADJACENT SINK. 1/2" H&C UP. ROUTE 1/2" H&C AND 1 1/2" SANITARY HORIZONTALLY THROUGH WALL. DROP 3/4" C TO WALL HYDRANT. DROP 1/2" H&C, 2" WASTE DOWN, AND 2" VENT RISE TO LAVATORY. DROP 1/2" C 3" WASTE DOWN TO WATER CLOSET. 2" SANITARY UP. 2" VENT DOWN. DROP 1/2" H&C AND 3" WASTE WITH P -TRAP TO MOP SERVICE SINK. 2" SANITARY WITH P -TRAP UP. 3" SANITARY UP. 3" SANITARY UP, 3" SANITARY DOWN. DROP 3/4" INDIRECT WASTE FROM FURNACE AND SPILL TO FLOOR DRAIN THROUGH 1 1/2" PHYSICAL AIR GAP. PROVIDE ALL TRAPS AND NEUTRALIZERS PER MECHANICAL EQUIPMENT MANUFACTURERS INSTRUCTIONS AND ALL APPLICABLE CODES. 21 DROP 1/2" H&C, 1 1/2" WASTE WITH 2" P -TRAP DOWN TO TUB. VALVE END OF TUB TO BE AWAY FROM ENCLOSED CHASE FOR SERVICE PURPOSES. 22 DROP 1/2" H&C, 2" WASTE WITH P -TRAP DOWN TO SHOWER. SHOWER AND VALVE MUST BE INSTALLED PER ADA REQUIREMENTS. 23 DROP 1/2" H&C, 2" SANITARY DOWN, AND 2" VENT RISE IN WALL. BRANCH 1 1/2" SANITARY TO ADJACENT SINK. 24 2" VENT UP. 25 4" RADON VENT UP, 4" RADON VENT DOWN. 26 4" RADON VENT DOWN. NOTE: ALL STORM, SANITARY, AND VENT STACKS SHALL HAVE A TWO-WAY CLEANOUT TEE INSTALLED AT THE BASE OF THE STACK (12" AFF TO CL OF TEE) PER THE PLUMBING CODE OF NEW YORK STATE, WHICH WILL ACT AS A STACK CLEANOUT AND AS A CHANGE OF DIRECTION CLEANOUT FOR PIPING UP TO 40' DOWNSTREAM. NOTE: ALL TOWN HOME UNITS ARE TYPICAL OF UNIT TO THE RIGHT FIRST FLOOR PLAN DRAWING NOTES 27 4" RADON VENT UP. 28 ROUTE 1/2" H&C AND 1 1/2" WASTE THROUGH BACK OF CABINET. 29 DROP 3/4" C TO WALL HYDRANT. ROUTE 3/4" C THROUGH JOIST CAVITY AND DROP TO WALL BEHIND KITCHEN CABINET. CONNECT WITH SHUTOFF VALVE TO MAIN COLD WATER SUPPLY IN KITCHEN SINK BASE CABINET. WALL HYDRANT TO BE LOCATED IN BUILDING END UNITS ONLY. 30 1/2" H&C AND 1 1/2" SANITARY WITH P -TRAP UP TO SHOWER. 31 1/2" C AND 3" SANITARY UP TO WATER CLOSET. 32 1/2" H&C AND 2" SANITARY UP TO LAVATORY. 33 3/4" H&C UP TO MECHANICAL ROOM. 34 1/2" H, 3/4" C, 2" VENT UP. 35 ROUTE 1/2" H, 1" C, 2" SANITARY UP THROUGH WALL. BRANCH 1 1/2"' SANITARY TO KITCHEN SINK. 36 3/4" DOMESTIC WATER SERVICE UP IN SINK BASE CABINET. PROVIDE MAIN SHUTOFF VALVE IN CABINET. COORDINATE RISER AND VALVE LOCATIONS WITH FINAL MILLWORK VENDOR DRAWINGS. 37 COORDINATE GAS Mt°I'tR AND R'ISER'INSTALLATION AND LOCAT 1:1N J'W'V"I'rk FEL •&-s SUPPLIER, CIVIL DRAWINGS, AND ALL OTHER APPLICABLE TRADES. RISERS AND DISTRIBUTION LINES TO BE SIZED AS INDICATED ON P100. 38 1" G DOWN TO SHUTOFF VALVE AND GAS SUPPLY RISER. 39 PROVIDE DISHWASHER BRANCH TEE INLINE WITH WASTE ABOVE P -TRAP AND PROVIDE SHUTOFF VALVE WITH 3/8" COMPRESSION OUTLET ON HOT WATER SUPPLY FOR DISHWASHER. 40 4" SANITARY WALL PLATE CLEANOUT. 41 ROUTE 3/4" CONDENSATE DRAIN FROM DSS (BY OTHERS) TO MECHANICAL RM 100B AND SPILL TO FLOOR DRAIN THROUGH 1 1/2" PHYSICAL AIR GAP. SANITARY SEWER TO HAVE CLEANOUT AT CONNECTION TO SITE SEWER AS PART OF REQUIRED HOUSE TRAPS. REFER TO SITE DRAWINGS FOR DETAIL. 3/4"C 1/2"H 4"RADON 1/2"H TSAR 3/4"C 3/4"C 3/4 12'H 112"G 25 N 2,•C. LAV -A WC -A NOTE: RADON MITIGATION SYSTEM TO BE INSTALLED AT UNITS INDICATED ON P100A. C TV 3"5 AN TYPICAL TOWNHOME FIRST FLOOR PLAN - PLUMBING 1/8" = 1'-01' 112"C A GAS METER (BY UTILITY COMPANY, COORDINATE FINAL LOCATION WITH SITZ H0 LT ARHITECTS Architecture Planning Interior Design 217 North Aurora Street Ithaca NY 14850 p 607.273.7600 f 607.273.0475 ENY ECHANICAL CONTRACTORS NG ' i"YF:ATi NG " FP) I1 P ROTECT l O N 11 COMFORT STREET ROCHESTER, NEW YORK 14620 585-232-280O THESE_ DOCUMENTS AND ALL IDEAS, ARRANGFMFNY, DEt,SIGNS AND PI.AN5 INDICATED THEKEON OR PRESENTED THEREBY ARE OWNED AND REMAIN THE PROPERTY OF KENNEDY MECHANICAL INC. AND NC) PART THEREOF SHALL BE UTIh1JED BY ANY PERSON, FIRM, OK CORPORATION FOR, ANY PURPOSE WHATSOEVER EXCEPT WITH THE SPECIFIC WRITTEN PERMISSION Or F/INNTDY MECHANICAL INC, ALL RIGHTS RESERVED ler Mechanical Design Services 66. Panciamaira, buiV,lirc; :Ale 2.o] F ate.i4625 „i*.F;I,j;II WARNING: It is a violation of New York State Law for any person, unless acting under the direction of a licensed Architect, to alter this document in any way. If a document bearing the seal of an Architect is altered, the altering Architect shall affix to such document his seal and the notation "altered by" followed by his signature, the date of such alteration, and a specific description of the alteration. REVISION SCHEDULE NAME DATE STONE QUARRY APARTMENTS 5 AUG 2014 STONE QUARRY APARTMENTS, LL z 0 D DATE: PROJECT: OTHER: DRAWN BY: 7/18121114 2012059 TB APARTMENT BLDG./TH FIRST FLOOR PLANS PLUMBING P101 5 10 C B A APARTMENT BLDG. SECOND FLOOR PLAN - PLUMBING 1/8" = LAV -A 3/4"H 6 7 8 9 10 3/4"C 3/4'H 314'C /4"HWR WC -A 2"SAN; 3SA 1 3" AN 2 A 8T -A 2'SAN BT -P; 2"SAN 0O 314"H 3/4" FD' -8 2'C 3/4"'C LAS -A ?SAN 2'SAN K 2'H 3/4"HWR 3" AN 3141-! 2"SAN. A A 2"SAN BT -A 3/4'H 3/4"C 11/2"SAN q -1114"H 11,12T 1/4"C I/4''H 3/4"H 1'C V-A 2 2'SAN 3/4"C 3/4'C 3/4"H 3/4'HWR A 1t4" DON KS -A 314"C /4'C /4"H .07-3/4"H 3/4"H 1 SECOND FLOOR PLAN DRAWING NOTES 3/4" G DOWN, 1/2" G UP. BRANCH 1/2" G TO RANGE. PROVIDE SHUTOFF VALVE (TIGHT TO WALL), UNION, DIRT LEG, AND FINAL CONNECTION POINT FOR APPLIANCE. COORDINATE LOCATION AND TERMINATION WITH APPLIANCE MANUFACTURER, MILLWORK DRAWINGS, AND BUILDING OWNER, RANGE MUST BE ABLE TO SIT FLUSH WITH REAR WALL WHEN INSTALLED. 2 3/4" G DOWN, 1/2" G UP. BRANCH 1/2" G TO FURNACE. PROVIDE SHUTOFF VALVE, UNION, DIRT LEG, AND FINAL CONNECTION TO APPLIANCE IN ACCORDANCE WITH ALL FUEL GAS CODES AND REGULATIONS. 2" VENT UP, 2" VENT DOWN, 4 3" WASTE STACK VENT UP, 3" WASTE STACK VENT DOWN. BRANCH 1 1/2" TO ADJACENT KITCHEN SINK. ROUTE WASTE STACK VENT PER ALL APPLICABLE CODES AND REGULATIONS. 5 ROUTE 1/2" H&C AND 1 1/2" SANITARY HORIZONTALLY THROUGH WALL. 6 1/2" H&C UP TO SINK ON FLOOR ABOVE. 7 PROVIDE BALANCING STATION CONSISTING OF CHECK VALVE, CIRCUIT BALANCING VALVE, AND SHUTOFF VALVE, SET CBV FOR .5 GPM. 8 2" WASTE STACK VENT UP, 2" WASTE STACK DOWN. BRANCH 1 1/2" TO ADJACENT KITCHEN SINK, ROUTE PER ALL APPLICABLE WASTE STACK VENT REGULATIONS, 9 10 11 12 13 14 DROP 3/4" INDIRECT WASTE FROM FURNACE AND SPILL TO FLOOR DRAIN THROUGH 1 1/2" PHYSICAL AIR GAP. PROVIDE ALL TRAPS AND NEUTRALIZERS PER MECHANICAL EQUIPMENT MANUFACTURERS INSTRUCTIONS AND ALL APPLICABLE CODES. 1/2" H&C DOWN TO HALF BATH ON FLOOR BELOW. 4" RADON VENT UP, 4" RADON VENT DOWN. 3/4" G UP, 3/4" G DOWN. 3" SANITARY UP. 2" SANITARY WITH P -TRAP UP. 15 1/2" H&C UP, 1/2" H&C DOWN. BRANCH 1/2" H&C TO TUB/SHOWER. DROP 1 1/2" WASTE WITH P -TRAP DOWN. VALVE END OF TUB TO BE AWAY FROM ENCLOSED CHASE FOR SERVICE PURPOSES. 16 1/2" C UP, 1/2" C DOWN. BRANCH 1/2" C TO WATER CLOSET. DROP 3" WASTE DOWN FROM WATER CLOSET. 17 1/2 H&C UP, 1/2" H&C DOWN. BRANCH 1/2" H&C TO LAVATORY. DROP 2" WASTE DOWN AND 2" VENT RISE TO LAVATORY. 18 2" SANITARY UP. 19 3" SANITARY DOWN. 21 H&C SUPPLIES TO UNIT TOILET ROOMS. REFER TO P106 FOR TYPICAL LINE SIZING AND DISTRIBUTION. 22 H&C SUPPLIES TO UNIT KITCHENS. REFER TO P106 FOR TYPICAL LINE SIZING AND DISTRIBUTION. 23 2" SANITARY UP, 2" SANITARY DOWN. NOTE: ALLTOWNHOME UNITS ARE TYPICAL OF UNIT TO THE RIGHT U) SECOND FLOOR PLAN DRAWING NOTES 24 3/4" C UP, 3/4" C DOWN (ROOF HYDRANT SUPPLY). 25 4" STORM UP, 4" STORM DOWN. 26 4" OVERFLOW STORM UP, 4" OVERFLOW STORM DOWN. 27 2 1/2" C, 2'" H, 3/4" HWR DOWN. 28 DROP 1/2" C, 3" WASTE DOWN TO WATER CLOSET, 29 DROP 1/2" H&C, 2" WASTE DOWN, AND 2" VENT RISE TO LAVATORY. 30 DROP 1/2" H&C, 1 1/2" WASTE WITH P -TRAP DOWN TO TUB. VALVE END OF TUB TO BE AWAY FROM ENCLOSED CHASE FOR SERVICE PURPOSES, 31 ROUTE 1/2" G FROM ADJACENT ROOM TO FURNACE. PROVIDE SHUTOFF VALVE, UNION, DIRT LEG, AND FINAL CONNECTION TO APPLIANCE IN ACCORDANCE WITH ALL FUEL GAS CODES AND REGULATIONS, 32 1/2" G DOWN, 33 1" C, 1/2" H DOWN. 34 3/4" H&C DOWN. 35 1"G DOWN. 36 PROVIDE DISHWASHER BRANCH TEE INLINE WITH WASTE ABOVE P -TRAP AND PROVIDE SHUTOFF VALVE WITH 3/8" COMPRESSION OUTLET ON HOT WATER SUPPLY FOR DISHWASHER. 37 ROUTE 3/4" CONDENSATE DRAIN FROM DSS )BY OTHERS) TO MECHANICAL RM 224E AND SPILL TO FLOOR DRAIN THROUGH 1 1/2" PHYSICAL AIR GAP. 1'G NOTE: RADON MITIGATION SYSTEM TO BE INSTALLED AT UNITS INDICATED ON P100A. TYPICAL TOWNHOME SECOND FLOOR PLAN - PLUMBING 1/8" = 1-0" Architecture Planning Interior Design 217 North Aurora Street Ithaca NY 14850 p 607.273.7600 f 607.273.0475 KENNEDY C'HANICA! CONTRACTORS P4 Ld SOBINGa+°4L:A"1°NG.FIHF. PItOTRCT'!ON / / C©MI-ORT 5TR.ET R©CIiW5TER, NEW YORK 14620 585-232-2840 THESE DOCUMENTS AND ALL IDEAS,ARRANGEMENT, DESIGNS AND PLANS INDICATED THEREON OR. PRESENTED THEREBY ARE OWNED AND REMAIN THE r ROPERTY OF KENNEDY MECHANICAL INC. AND NO PART THEREOF St i, EIE UTILLZED BY ANY PERSON. FIRM, OR CORPORATION FOR ANY PURPOSE WHATSOEVER EXCEPT WITH THE SPECIFIC WRITTEN PERMISSION OF KENNEDY MECHANICAL. INC. Al!; RIGHTS RESERVED mer Mecha 5 'ai!U(I F i '' I. 8tl x1l ct .2, .w'..IYk. 21C NY 14 cCITr WARNING: It is a violation of New York State Law for any person, unless acting under the direction of a licensed Architect, to alter this document in any way. If a document bearing the seal of an Architect is altered, the altering Architect shall affix to such document his seal and the notation "altered by" followed by his signature, the date of such alteration, and a specific description of the alteration. REVISION SCHEDULE STONE QUARRY APARTMENTS DATE 5AUG 2©14 RTMENTS, LLC STONE QUARRY AP >- z 0 DATE: 7/18/2014 PROJECT: 2012059 OTHER. DRAWN BY: JTB APARTMENT BLDG./TH SECOND FLOOR PLANS - PLUMBING D B A E D APARTMENT BLDG. THIRD FLOOR PLAN - PLUMBING 1/8" = 11-01I KS -A °SAN KS -A 6 7 8 9 10 0 THIRD FLOOR PLAN DRAWING NOTES DROP 1/2" H&C DOWN. ROUTE WASTE HORIZONTALLY THOUGH WALL TO ADJACENT WASTE STACK VENT RISER. 2 3" WASTE STACK VENT. 3" WASTE DOWN, 3" VENT UP ABOVE BRANCH CONNECTION, ROUTE PER ALL APPLICABLE WASTE STACK VENT REGULATIONS. 1/2" G DOWN, PROVIDE SHUTOFF VALVE (TIGHT TO WALL), UNION, DIRT LEG, AND FINAL CONNECTION POINT FOR APPLIANCE. COORDINATE LOCATION AND TERMINATION WITH APPLIANCE MANUFACTURER, MILLWORK DRAWINGS, AND BUILDING OWNER. RANGE MUST BE ABLE TO SIT FLUSH WITH REAR WALL WHEN INSTALLED. 4 DROP 1/2" H&C, 2" WASTE DOWN, 2" VENT RISE TO LAVATORY. RISE 2" VENT ADJACENT TO LAVATORY AND CONNECT TO FIXTURE VENT RISE A 6" ABOVE FIXTURE FLOOD RIM. 5 DROP 1/2" C, 3" WASTE DOWN TO WATER CLOSET. 6 DROP 1/2" H&C, 1 1/2" WASTE WITH P -TRAP DOWN TO TUB, VALVE END OF TUB TO BE AWAY FROM ENCLOSED CHASE FOR SERVICE PURPOSES, 7 4" RADON VENT UP, 4" RADON VENT DOWN. DROP 3/4" INDIRECT WASTE FROM FURNACE AND SPILL TO FLOOR DRAIN THROUGH 1 1/2" PHYSICAL AIR GAP. PROVIDE ALL TRAPS AND NEUTRALIZERS PER MECHANICAL EQUIPMENT MANUFACTURERS INSTRUCTIONS AND ALL APPLICABLE CODES. 9 1/2" G DOWN. 1/2" G TO FURNACE, PROVIDE SHUTOFF VALVE, UNION, DIRT LEG, AND FINAL CONNECTION TO APPLIANCE IN ACCORDANCE WITH ALL FUEL GAS CODES AND REGULATIONS. 10 2" WASTE STACK VENT. 2" WASTE DOWN, 2" VENT UP ABOVE BRANCH CONNECTION. ROUTE PER ALL APPLICABLE WASTE STACK VENT REGULATIONS. 11 3/4" C UP, 3/4" C DOWN (ROOF HYDRANT SUPPLY). 12 4" OVERFLOW STORM UP. 4" OVERFLOW STORM DOWN. 13 4" STORM UP, 4" STORM DOWN. 14 2" VENT UP, 2" VENT DOWN. 15 (2) 2°' VENTS DOWN, (1) 2" VENT UP. CONNECT VENTS TOGETHER AT 42" AFF. 16 INCREASE VENT BELOW TO 3" BELOW ROOF DECK AND RISE TO 18" ABOVE ROOF SURFACE. PAINT VENT RISER TO MATCH ROOF FINISH COLOR. 17 4" RADON VENT DOWN. 18 INSTALL RF -A NEAR ACCESS HATCH (IN CEILING BELOW). RISE 4" RADON VENT THROUGH FAN, RISE THROUGH ROOF, AND INSTALL RADON VENT CAP AT TERMINUS OF RISER (18" ABOVE ROOF SURFACE). PAINT RISER AND CAP TO MATCH ROOF FINISH COLOR. 19 CONCENTRIC VENT KIT FOR WATER HEATER COMBUSTION AIR INTAKE AND EXHAUST. REFER TO MECHANICAL PLANS. SIZE PER MANUFACTURERS REQUIREMENTS BASED ON RUN LENGTH AND EQUIVALENT FITTING LENGTH. 20 PROVIDE DISHWASHER BRANCH TEE INLINE WITH WASTE ABOVE P -TRAP AND PROVIDE SHUTOFF VALVE WITH 3/8" COMPRESSION OUTLET ON HOT WATER SUPPLY FOR DISHWASHER. 21 ROUTE 3/4" CONDENSATE DRAIN FROM DSS (BY OTHERS) TO MECHANICAL RM 332D AND SPILL TO FLOOR DRAIN THROUGH 1 1/2" PHYSICAL AIR GAP. 4 LiliADON RF -A NOTE: RADON MITIGATION SYSTEM TO BE INSTALLED AT UNITS INDICATED ON P100A, TYPICAL TOWNHOME ROOF PLAN - PLUMBING 1 /8" = 1 I -0'I HO LTARCHITE TS Architecture Planning Interior Design 217 North Aurora Street. Ithaca NY 14850 p 607.273.7600 f 607.273.0475 KENNEDY* MECHANICAL CONTRACTORS UMRING+NEAYING+FIRE PIPOT'ECTIO / / COMFORT 5TREE7- ROCh`ESTER, NEW )CORK 1462© 585-232-2500 TIIESE DOCUMENTS AND ALL IDEAS, ARRANGEMENT, DESIGNS AND PIANS INDICATED THEREON OR PRESENTED THEREBY AKE OWNED AND KEMAIN THE PROPERTY OF KENNEDY MECHANICAL ENC. AND NO PART THEREOF SHAH. BE UTELIZED BY ANY PERSON, FIRM, OR C(]KPORATION EON ANY PURPOSE WHATSOEVER. EXCEPT W1Th THE SPECINL WRITTEN PERMI5SION OF KENNEDY MECHANICAL_ INC. ALL RIGHTS tE`SERVED er ech n WARNING: It is a violation of New York State Law for any person, unless acting under the direction of a licensed Architect, to alter this document in any way. If a document bearing the seal of an Architect is altered, the altering Architect shall affix to such document his seal and the notation "altered by" followed by his signature, the date of such alteration, and a specific description of the alteration, REVISION SCHEDULE NAME DATE STONE QUARRY APARTMEN 5 AUG 2014 TMENTS, LLC STONE QUARRY AP DATE: 18/2014 PROJECT: 2012059 OTHER: DRAWN BY: JTB APARTMENT BLDG./TH THIRD FLOOR AND ROOF /ATTIC PLANS - PLUMBING P103 A 10 G APARTMENT BUILDING ROOF PLAN - PLUMBING 118" = 1-0" 2'U 2"V Iry 2'V 2v 2'V 3V 3V DASHED AREA. REPRESENTS MECHANICAL ROOF RECESS - DRAINAGE AREA = 510 SQ. FT. - ALL OTHER ROOFS SLOPE AWAY 2V 2'V 2V 4 2'V 2v 2V 3V 3'V 3V 3V 4.RADON ATTIC/ROOF PLAN DRAWING NOTES 1 2" VENT DOWN. 2 3" VENT DOWN. 3 3" VENT UP THROUGH ROOF. EXTEND VENT 18" ABOVE ROOF SURFACE. COORDINATE FLASHING INSTALLATION WITH ROOFING CONTRACTOR, PAINT RISER TO MATCH ROOF FINISH COLOR. 4 4" RADON VENT DOWN, 4" RADON VENT UP TO RADON FAN. INSTALL FAN PER MANUFACTURER HEIGHT AND CLEARANCE. SECURE PIPE ON RISE WITH RISER CLAMP, THREADED ROD, AND APPROPRIATE FASTENER TO PREVENT LATERAL MOVEMENT, PROVIDE SUPPORT UNDER AND ABOVE FAN. PROVIDE RADON VENT CAP AT PIPE TERMINUS. 6 3" STORM UP TO ROOF DRAIN. COORDINATE ROOF DRAIN INSTALLATION WITH ROOFING CONTRACTOR AND MECHANICAL EQUIPMENT. 7 3" OVERFLOW STORM UP TO OVERFLOW ROOF DRAIN. COORDINATE OVERFLOW ROOF DRAIN INSTALLATION WITH ROOFING CONTRACTOR AND MECHANICAL EQUIPMENT. 8 4" STORM DOWN. 9 4" OVERFLOW STORM DOWN. 10 3/4" C DOWN FROM FROST -FREE ROOF HYDRANT. COORDINATE INSTALLATION WITH ROOF CONTRACTOR. COORDINATE CHASE HEIGHT TO DECK WITH FRAMING. ENSURE UNDERSIDE OF ROOF DECK IS INSULATED AND DRAFTSTOPPING IN PLACE. NOTE: PIPING SHOWN ON THIS PLAN TO BE LOCATED IN ATTIC SPACE BETWEEN ROOF DECK AND THIRD FLOOR CEILING. Architecture Planning Interior Design 217 North Aurora Street Ithaca NY 14850 p 607.273.7600 f 607.273.0475 K NNEDY ANfCAL CONTRACTORS :: F 4 AT NG4 FPRE FF?OT€CTlON / / COMFORT STREET ROCHESTER, NEW YORK /46'20 585-232-2500 THESE DOCUMENTS AND ALL IDEAS. AR _N DESIGNS AND PIANS INDICA-VW ThERAON OR PRESENTED THEREBY ARE OWNED AND REMAIN TYPE PROPERTY Or KENNEDY MECHANICAL INC. AND NO FART THEREOF SPALL. SF UTPk 1717D BY ANY PERSON., FIRM., OR CORPORATION FOR ANY PURPOSE WHATSOEVER. EXCEPT WITH THE SPECIFIC WRITTEN PERMISSION OF KENNEDY MECHANICAL INC. ALL RIGHTS RESERVED ger h u i25 PHI c,ciTr N,; WARNING: It is a violation of New York State Law for any person, unless acting under the direction of a licensed Architect, to alter this document in any way. If a document bearing the seal of an Architect is altered, the altering Architect shall affix to such document his seal and the notation "altered by" followed by his signature, the date of such alteration, and a specific description of the alteration. REVISION SCHEDULE NAME DATE 15 AUG 2014 STONE QUARRY APARTMENTS STONE QUARRY APARTMENTS, LL F DATE: 7/18/2014 PROJECT: 2012059 OTHER: DRAWN BY: TB APARTMENT BLDG. ROOF /ATTIC PLAN - PLUMBING P104 5 2:04:57 PM 2 4 METER BYPASS LOOP VALVES (IF REQUIRED BY WATER PURVEYOR) SECTION AT DOMESTIC WATER SERVICE 1/4" = ENLARGE PARTIAL APARTMENT BLDG. FIRST FLOOR PLAN - PLUMBING 1/4" = 7 1/2" G TO DRYER. PROVIDE ,1 SHUTOFF VALVE, UNION, i DIRT LEG, AND POINT OF CONNECTION FOR UNIT. (TYPICAL OF 7) HA HA ----P01 "EF SIZE HAMMER ARRESTER I52I -REFER TO P001 FOR MAKE AND MODEL 4"SAN COORDINATE LINT INTERCEPTOR AND LAUNDRY ROOM PIPING WITH STRUCTURAL DRAWINGS AND GEOFOAM, CONTRACTOR. SECTION THROUGH LAUNDRY ROOM 3/8" =1'-0" 4"5AN 2 1/2"C GENERAL NOTE: BACKFLOW PREVENTERS TO BE INSTALLED PER ALL NEW YORK STATE DEPARTMENT OF HEALTH AND WATER PURVEYOR REQUIREMENTS FIRST FLOOR 399' - 6" FIRST FLOOR 399'-' 6" SHUTOFF VALVE, UNION, AND DIRT LEG - INSTALL PER FUEL GAS CODE (TYPICAL) 10 0 PARTIAL ENLARGED FIRST FLOOR PLAN DRAWING NOTES 1 DROP 4" OVERFLOW STORM TO OVERFLOW DOWNSPOUT. MOUNT DOWNSPOUT 24" ABOVE FINISHED GRADE AND PROVIDE SPLASH BLOCK. 2 4" OVERFLOW STORM UP. 3 4" STORM UP, 4" STORM DOWN. 4 3/4" C UP (ROOF HYDRANT SUPPLY). DROP 2" PUMPED WASTE TO SUMP PUMP. PROVIDE CHECK VALVE AND ISOLATION VALVE ON RISE. ROUTE DISCHARGE PIPING OVERHEAD ABOVE CORRIDOR CEILING, COORDINATE SUMP PUMP INSTALLATION WITH MASONRY CONTRACTOR, ELEVATOR VENDOR, AND ALL APPLICABLE TRADES, 6 4" SANITARY UP, BRANCH 4" SANITARY TO P -TRAP WITH STANDPIPE WITH INCREASER FUNNEL, RISE 2" VENT. SPILL PUMPED WASTE FROM SUMP PUMP THROUGH 4" AIR GAP TO FUNNEL ON STANDPIPE. 7 2" VENT DOWN. 8 2" SANITARY DOWN. 9 2" SANITARY UP. 10 2" VENT DOWN. 11 DROP 1/2" H&C, 2" WASTE DOWN, 2" VENT RISE TO SINK. ROUTE PIPING FROM RISERS TO SINK THROUGH WALL. 12 3/4" G UP. 13 2" SANITARY WITH P -TRAP UP. 14 3" SANITARY UP, 3" SANITARY DOWN. 15 3" SANITARY UP. 16 DROP 1 11/4" G TO (2) WATER HEATERS, BRANCH 3/4" G TO EACH UNIT AND PROVIDE SHUTOFF VALVE, UNION, DIRT LEG, AND FINAL CONNECTION TO UNIT. 17 DROP 3/4" G TO FURNACE. PROVIDE SHUTOFF VALVE, UNION, DIRT LEG, AND FINAL CONNECTION TO UNIT. 18 2 112" C, 2" H, AND 3/4" HWR UP. 19 REFER TO WATER HEATER SCHEMATIC THIS PAGE FOR WATER HEATER PIPING. 20 DROP 1/2" H&C, 2" WASTE DOWN, AND 2" VENT RISE TO LAVATORY. BRANCH 1/2" C IN WALL TO ADJACENT WATER CLOSET. 21 DROP 1/2" C, 4" WASTE DOWN TO WATER CLOSET. 22 DROP 112" H&C, 2" WASTE DOWN, AND 2" VENT RISE TO SINK, 23 COMBUSTION AIR INTAKE AND EXHAUST UP IN WALL REFER TO MECHANICAL DRAWINGS FOR ROUTING. 1/2"' EXPANSION TANK (XT -A RECIRC. PUMP 22 WATER HEATER (D 1" Lii 16HH WATER HEATER )DWH-A) Lip WATER HEATER SCHEMATIC 1/2" = 11-01' RECIRC. PUMP G G AQUASTAT CW ----------+--HI +1 I I - RECIRC PUMP CW TEMP. GAUGE B.V. CHK. V. MIXING VALVE (TMV-A) STORAGE TANK (ST -A) 1 1/2" n +1+ 110' HW CIRCUIT SETTER -- GAS SUPPLY CW SUPPLY -() L. 1» 110° HW - 110° HWR GENERAL NOTES: - INSTALL ALL EQUIPMENT PER MANUFACTURERS STRICT INSTRUCTIONS. - MAINTAIN EQUIDISTANT PIPING LENGTHS AT WATER HEATERS FOR BALANCED OPERATION. FIN. FLOOR HO LTARCH ITECTS Architecture Planning Interior Design 217 North Aurora Street Ithaca NY 14850 p 607.273.7600 f 607.273.0475 KENNEDY MECHANICAL CONTRACTORS PLUMEHNG.HEATING.FIRE PROTECTION / / COMFORT STREET ROCHESTER, NEW YORK 14620 565-232-24300 THESE DOCUMENTS AND Al], IDEAS, AKKANGEMENIT, DESIGNS AND FLANS INDICATED THEREON OK PRESENTED THEREBY ARE OWNED AND REMAIN THE PROPERTY OF KENNEDY MECHANICAL INC„. AND NO FART THEREOF SHAD BE UTILIZED BY ANY PERSON, FIRM, OR CORPORATION FOR ANY PURPOSE WHATSOEVER EXCEPT WITH THE SPECIEIG VM111-EN PERMISSION OF KENNEDY MECHANICAL INC. API. RIGHTS RESERVED uamer Mechani resign Services 22512a02r5ma Trat, •13,„iiidlng 2.02,2* 210 Ro0hint.ef , f02' 121020 2.:15-22-58-1E*1 WARNING: It is a violation of New York State Law for any person, unless acting under the direction of a licensed Architect, to alter this document in any way. If a document bearing the seal of an Architect is altered, the altering Architect shall affix to such document his seal and the notation "altered by" followed by his signature, the date of such alteration, and a specific description of the alteration. REVISION SCHEDULE NAME DATE STONE QUARRY APARTMENTS RTMENTS, LL 0 w 0 F- U) ITHACA, NY DATE: 7/18/2014 PROJECT: 2012059 OTHER: DRAWN BY: JTB ENLARGED FLOOR PLAN SECTIONS AND ELEVATIONS - PLUMBING P105 2 4 S 7 10 ISOMETRIC VIEW - TYPICAL TOWNHOME PLUMBING N.T.S. 2 WC -A KS -A 1/211 1/rc 11TH v2TC 1/2 11 314"H (4'C SUPPLY PIPING CONTINUED IN 2ND FLOOR CEILING - REFER TO P102 ISOMETRIC VIEW N.T.S. PICAL APARTMENT UNIT DOMESTIC WATER DISTRIBUTION GENERAL ISOMETRIC VIEW NOTES: THESE VIEWS REPRESENT TYPICAL CONDITIONS IN THE PROJECT. WHILE FIXTURE LOCATION MAY VARY THROUGH THE BUILDING, PIPE SIZES INDICATED SHALL BE MAINTAINED. VENT PIPING CONTINUED IN ATTIC - REFER TO P104 ISOMETRIC VIEW - TYPICAL APARTMENT UNIT SANITARY DRAINAGE N.T.S. 10 SANITARY PIPING CONTINUED UNDERSLAB - REFER TO P100 TARCHITECTS E T Architecture Planning Interior Design 217 North Aurora Street Ithaca NY 14850 p 607.273.7600 f 607.273.0475 I ENNEDY CHANICAL CONTRACTORS 4 AF'RNA A'EARE, PAOIECTIoki 1 I COMFORT 5 rREET Rt7Cl1E5TEf', NEW YORK 14620 5695-232-2000 DOC4JMENI i AND AJ-tDfti, ARRANGEMENT* .PLANS INDICATIO? THEREON OR ENTF'D'TF#FRF-F3Y A f OWNED AND REMAIN THE Elt.TY OF KFNNFPY MEC11ANICAI.. INC. AND NO PART 'TYtirF;,r;OF511AJ. [M IJ'TTIJLED £1Y ANY PEI OON, FIRM. OR LION FOR ANY PURPOSE. WMATSOF.VWR EXCEPT E SPECIFIC WRIITTIN :PFRMIS`SION OF F NNEOY ICAF. INC. AI.I- RIGFIT`.';i RESERVED 62'3 PancraFria WARNING: It is a violation of New York State Law for any person, unless acting under the direction of a licensed Architect, to alter this document in any way. If a document bearing the seal of an Architect is altered, the altering Architect shall affix to such document his seal and the notation "altered by" followed by his signature, the date of such alteration, and a specific description of the alteration. REVISION SCHEDULE NAME I DATE STONE QUARRY APARTMEN J ..J STONE QUARRY APARTMENTS DATE: 7/18/2014 PROJECT: 2012059 OTHER:. DRAWN Y. JT ISOMETRIC VIEWS - PLUMBING P106 7 9 10 B