Loading...
HomeMy WebLinkAboutStone Quarry Apartments - Fire Protection1 2 4 5 6 7 8 9 10 C 80 DS PES 2.00 20 DS 2-60 CR\ T GENERAL NOTES: A. KENNEDY MECHANICAL TO PROVIDE AUTOMATIC SPRINKLER SYSTEM, TO BE DESIGNED IN ACCORDANCE WITH NFPA 13R, 2007 EDITION FOR RESIDENTIAL OCCUPANCIES UP TO FOUR STORIES IN HEIGHT. B. ALL WORK TO BE IN ACCORDANCE WITH NFPA 13R 2007 ED, NYS FIRE CODE, AND LOCAL ORDINANCES. C. ALL NEW PIPING TO COMPLY WITH ALL APPLICABLE REGULATIONS AND SHALL BE SIZED HYDRAULICALLY, D. FINAL HYDRAULICALLY CALCULATED PLANS AND ALL NECESSARY DOCUMENTS TO BE SUBMITTED TO THE ITHACA FIRE MARSHALL UNDER SEPARATE COVER FOR REVIEW AND APPROVAL PRIOR TO CONSTRUCTION. E. THE ENTIRE SPRINKLER SYSTEM SHALL BE TESTED AT 200PSIG FOR 2 HRS PER NFPA 13R, 2007 ED. F. ALL HANGERS SHALL BE INSTALLED PER NEPA 13R 2007 ED. G. BUILDING OWNER SHALL MAINTAIN A MINIMUM TEMPERATURE OF 40°F AT ALL AREAS OF THE WET SPRINKLER SYSTEM PIPING TO PREVENT FREEZING. H. IF TEMPORARY HEAT IS TO BE USED DURING CONSTRUCTION, GENERAL CONTRACTOR SHALL PAY CAREFUL NOTE TO AVOID OVERHEATING AT SPRINKLER HEADS, ALL FP PIPING WITH THE EXCEPTION OF THE MECHANICAL ROOM SHALL BE CPVC. MECHANICAL ROOM PIPING SHALL BE A135 STEEL PIPING WITH APPROVED FITTINGS. FIRE PROTECTION SYMBOLS LIST SYMBOL DESCRIPTION SYMBOL DESCRIPTION — FP — IQUICK FIRE PROTECTION PIPING 0 RESPONSE LISTED SEMI -RECESSED SPRINKLER HEAD AFF ABOVE FINISHED FLOOR RESIDENTIAL LISTED SEMI -RECESSED SPRINKLER HEAD PC PLUMBING CONTRACTOR QUICK RESPONSE LISTED HORIZONTAL SIDEWALL SPRINKLER HEAD FPC FIRE PROTECTION CONTRACTOR RESIDENTIAL LISTED HORIZONTAL SIDEWALL SPRINKLER HEAD 0- C- ELBOW UP, ELBOW DOWN DRY BARREL TYPE LISTED SIDEWALL SPRINKLER HEAD =.(1 DROP CONNECTION -3 CAP OR PLUG ROLL DOWN VISUAL FIDELITY NOTE: THIS DRAWING SET CONTAINS COLORED ELEMENTS TO CONVEY DESIGN INTENT AND TO EASE INTERPRETATION. IF THIS DRAWINGS SET IS RECEIVED IN MONOCHROME OR GRAYSCALE PLEASE CONTACT KENNEDY MECHANICAL INC. AT .THE NUMBER LISTED TO THE RIGHT FOR A COLOR PRINTED SET. FLOOR ABOVE -\ SEAL PENETRATION TEE LENGTH OF SPRINKLER IN HEATED SPACE TO BE PER MANUFACTURER CEILING DRYWALL INTERIOR WALL SURFACE JOIST FOR DECK/ CLG. ABOVE CAULK WEATHERTIGHT SEAL PENETRATION CONDITIONED SPACE DRY HEAD ESCUTCHEON EXTERIOR WALL SURFACE INSULATED WALL EXTERIOR / UNHEATED SPACE FROM MAIN RISER PIPE SIZE AS NOTED TEST VALVE IN READILY ACCESSIBLE LOCATION _ BUILDING STRUCTURE SMOOTH BORE CORROSION RESISTANT OUTLET GIVING FLOW EQUIVALENT TO ONE SPRINKLER SPLASH BLOCK CHECK VALVE 4" GALVANIZED PIPE, REFER TO PLANS FOR CONTINUATION -\ INTERIOR PIPING AND BODY MAY VARY FROM SHOWN TO CONFORM TO SYSTEM AND ARCHITECTURAL REQUIREMENTS BALL DRIP (SHOWN VERTICAL FOR CLARITY, SHALL BE INSTALLED HORIZONTALLY) FINISHED FLOOR • • • . • • . ° . B, . 0 , • EXTERIOR WALL WALL SIGN AS REQUIRED BY LOCAL AUTHORITY SEAL WALL PENETRATION WATER TIGHT, TYP. FIRE DEPARTMENT CONNECTION (5" STORZ STYLE TERMINATION) -PER ITHACA REQUIREMENTS - 36" ABOVE FINISHED GRADE 45° ELBOW WITH ESCUTCHEON. MATCH FINISH OF FIRE DEPARTMENT CONNECTION. FINISHED GRADE 4" min. 6" max TYCO HSW SEE SPRINKLER SCHEDULE W/ SEMI-REC PLATE 1" CPVC STANDOFF HANGER PIPE 1" CPVC fi TYCO HSW w/ SEMI•REC PLATE x112" CPVC ELBOW Ceiling 1" CNC STANDOFF HANGER 1" CPVC FLOOR JOIST FIRE STOP 2ND FLOOR PENETRATION 2nd Floo TYCO HSW w/ SEMI-REC PLATE p10' CAVE Spigot d Adopter CPVC Pipe - C BRANCH LINE CEILING TYCO HSW W/ SEMI -RC PLATE FIN FLOOR '-0" TL,pical Up & Dn to Sprinklers NTS lx 31' CNC TEE 2x4 WALL WITH RESILIENT CHANNEL ON ONE SIDE 1" CPVC Pipe TYCOHSWw/ SEMI-REC PLATE 112x112x1"CFVC TEE x\" CNC Spigot ad Adopter TYCO HSW u// SEMI-REC PLATE lx1\ CPVC TEE 2x4 WALL WITH RESILIENT CHANNEL ON ONE SIDE T/CDHSWw/ SEMI-REC PLATE 2x1\ 2x1" CNC TEE 2x4 WALL DRY HEAD SPRINKLER FOR UNCONDITIONED SPACE NO SCALE INSPECTOR'S TEST CONNECTION DETAIL NO SCALE FIRE DEPARTMENT CONNECTION DETAIL NO SCALE TYPICAL UP & DN TO SPRINKLERS NO SCALE 4 PENDENT VV/ GUARD RECESSED SIDEWALL asszmairrAP: lir.40o2rAwAratamatamr. • PENDENT SEMI RECESSED PENDENT IF OFFSET LENGTH EXCEED 2'-0" PROVIDE PIPE HANGER SPRINKLER BRANCH LINE 8YAYW .Ar$V4IPMPAP:4202YAK.,:fr REDUCER CONCEALED PENDENT NOTE: REFER TO LEGEND AND FLOOR PLANS FOR LOCATIONS AND TYPE, NOT ALL STYLES MAY BE USED TYPICAL ARMOVER SECTION N.T.S. HARDENED HEX HEAD SELF THREADING SCREW CPVC SINGLE STRAP HANGER • TYPICAL ARMOVER SECTION N T S HARDENED HEX HEAD SELF THREADING SCREW CPVC DOUBLE STRAP HANGER MAXIMUM DISTANCE BETWEEN HANGERS NOMINAL PIPE SIZE 3/4" 1-1/4" 1-1/2" 2-1/2" 3-1/2" STEEL PIPE EXCEPT THREADED LIGHTWALL N/A 12-0 I 12-0 15-0 15-0 15-0 5-0 15-0 15-0 15-0 15-0 15-0 THREADED UGHTWALL STEEL PIPE N/A 2-0 12-0 I 12-0 12-0 12-0 12-0 N/A N/A N/A N/A N/A CPVC PIPE 5-6 6-0 6-6 7-0 8-0 9-0 10-0 N/A N/A N/A N/A N/A TNPE 1- FOR 1' AND 1-1/4' .IPE AND HANGER 1N,E 2- FOR 1-1/2" AND 2' PIPE AND HANGER ilL TO RESTRAIN THE UPWARD MOVEMENT OF PIPE AS IT OCCURS DURING SPRINKLER HEAD ACTIVATION AS REQUIRED. SHALL BE LOCATED AT END HEADS WITHIN 24" FROM DROP TO PENDENT HEAD SURGE RESTRAINER EDT STEEL OR CPVC PLASTIC PIPE NTS HARDENED HEX HEAD SELF THREADING SCREW CPVC STAND-OFF HANGER SPRINKLER HEAD TYPES NO SCALE TYPICAL ARMOVER SECTIONS TYPICAL HARDWARE DETAILS HARDENED HEX HEAD SELF THREADING SCREW SIDE MOUNT CPVC DOU3LE FASTENER STRAP TYPE HANGER CPVC HANGER Sammy GST -20 for Wood //— 3/8" All Thread Rod Adjustable Swivel Ring TYPICAL HANGER NO SCALE Sammy Sidewinder SWG-20 for Wood 3/8" All Thread Rod Adjustable Swivel Ring TYPICAL HANGER NO SCALE 7 ick SECOND FLOOR ,„ II V 411--) 209' - 4 3/4" FLOW SWITCH vd RETARD 1 1/4" MAIN DRAIN PIPED TO EXTERIOR 21/2" CHECK VALVE TRIM FIRST FLOOR 200' - 0" INSPECTOR'S TEST CONNECTION WITH SIGHT GLASS AND 1/2" ORIFICE, CONNECT TO MAIN DRAIN PIPING TO EXTERIOR 0-300 GAUGE/ 3" BUTTERFLY VALVE w/ TAMPER 4" WATTS 757 DOUBLE CHECK ASSY \- 1/2" BALL DRIP 4" TO FIRE 4" GATE VALVE DEPT CONN W/ TAMPER SWITCH SPARE SPRINKLER HEAD CABINET NOTE: ALL VALVES IN FIRE SYSTEM SHALL BE PROVIDED WITH TAMPER SWITCHES 4" FIRE SERVICE 3" DOMESTIC SERVICE SECTION AT FP BACKFLOW DEVICE AND RISER (NTS) LFNCESSE Construction 75 Thruway' Parini Drive West Renrietta, NY 14,5.536 :8•• • 4 , WI ER A STAG HC)LTAFICHITECTS Architecture Planning Interior Design 217 North Aurora Street Ithaca NY 14850 p 607.273.7600 f 607.273.0475 r,t;KAIIIft AA COlti'LA,C B/TAT .alk&0164AATITs **et .1.,6*.stst ARA NtrttRA / / COMFORT STREET ROCHESTER, NEW YORK 14620 565-232-2500 ThESE DOCUMENTS AND ALL IDEAS, ARRANGEMENT, DESIGNS AND PLANS INDICATED THEREON OR. PRESENTED THEREBY ARE OWNED AND REMAIN THE PROPERTY OF KENNEDY MECHANICAL INC. AND NO PART ThEREOF SHALL DE UTILIZED BY ANY PERSON, FIRM, OR, CORPORATION FOR. ANY PURPOSE WHATSOEVER EXCEPT WITH THE SPECIFIC WRITTEN PERMISSION OF KENNEDY MECHANICAL INC. AU. RIGHTS RESERVED Baumer Mechanical Design Services 625 Panorama Trail, Building 2, Suds 210 Rochester, NY 14625 585-313-5819 WARNING: It is a violation of New York State Law for any person, unless acting under the direction of a licensed Architect, to alter this document in any way. If a document bearing the seal of an Architect is altered, the altering Architect shall affix to such document his seal and the notation "altered by" followed by his signature, the date of such alteration, and a specific description of the alteration. REVISION SCHEDULE NAME DATE STONE QUARRY APARTMENTS F - z z 0 F E C >- zB 0 DATE: 7/18/2014 PROJECT: 2012059 OTHER: DRAWN BY: AFL/JTB FIRE PROTECTION - GENERAL NOTES, A LEGEND, SCHEDULES FP001 6 8 10