Loading...
HomeMy WebLinkAboutConstruction Set drawings_Cornell StoreDRAWING STATUSISSUED FOR: CONSTRUCTIONAPRIL 24, 2017RENOVATION PROJECTLABELLA PROJECT NUMBER: 2170675CORNELL STORE CODE ISSUES RENOVATION PROJECT CORNELL STORE CODE ISSUES135 HO PLAZAITHACA, NY 14853CORNELL STOREPROJECT LOCATION MAPNTHE CORNELL STORE M1FIN. FLOORBOTTOM OF DECKHGT. VARIESEXISTING CEILINGNEW 4" RUBBER BASE3 5/8" x 20 GA. METAL STUDS @16" o.c.SUSPENDED CEILING5/8" GYPSUM BOARD WALLFINISH AND PAINT TO MATCHEXISTINGACOUSTICAL SEALANT BOTHSIDES, TYP.3 5/8" METAL STUD TRACKANCHORED TO FLOOR.3 1/2" SOUND ATTENUATION BATT.3 5/8" METAL DEFLECTION TRACKANCHORED TO DECKACOUSTICAL SEALANT BOTH SIDES, TYP.A-0011M13 5/8" METAL STUDS @ 16" O.C. CLAD W/ ONE LAYER 5/8" GYP. BD. ON BOTH SIDES& SOUND ATTENUATION BLANKETS UP TO UNDERSIDE OF DECK/STRUCTURE ABOVE.7'-9" A.F..F.EXISTING CEILINGFIELD VERIFY5/8" IMPACT RESISTANTGYP. BD. WALL FINISH ANDPAINT TO MATCH EXISTINGNEW 4" RUBBER BASEEXISTING FLOOR FINISHTO REMAINSTAIRBREAKROOMEXISTING FLOOR FINISHTO REMAINSCHEDULED METAL STUD& GYP. BD. PARTITION.REFER TO PARTITION TYPE.ACOUSTICAL SEALANT EACH SIDE, MAINTAIN5/8" DEPTH THICKNESS, TYP.A-00113"= 1'-0"NON-RATED GYP. BD. PARTITION & DECKTYP. PARTITION HEAD DETAIL @GYP. BD.: MAINTAIN 3/4"MIN. GAP BETWEEN GYP. BD.AND DECK ABOVE, TYP.FLOOR/ROOF DECK.DEFLECTION TRACK ASSEMBLY.METAL STUD RUNNER TRACK. MAINTAIN 3/4"GAP WITH DEFLECTION TRACK HEAD, TYP.VARIES3/4" MIN.GENERAL NOTES1&216758&7,216+$//&21)250727+(´1(:<25.67$7(81,)250),5(3527(&7,21$1'%8,/',1*&2'(µ/$7(675(9,6,217+(1(:<25.67$7((1(5*<&2'($1'$1<27+(5&2'(6GOVERNED BY THE JURISDICTION IN WHICH THE PROJECT IS BEING CONSTRUCTED.2.CONSTRUCTION SHALL COMPLY WITH ALL LOCAL, STATE AND FEDERAL CODES AND REGULATIONS.3.ALL DRAWINGS ARE GRAPHIC REPRESENTATIONS OF APPROXIMATE LOCATIONS OF NEW MATERIALS.IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY ALL CONDITIONS PRIOR TOCOMMENCEMENT OF WORK. CONTRACTOR SHALL NOT SCALE THE DRAWINGS.4.CONTRACTOR IS RESPONSIBLE FOR ALL MATERIALS, CONSTRUCTION METHODS, AND CRAFTSMANSHIP.5.CONTRACTOR IS TO VERIFY ALL EXISTING CONDITIONS, REQUIREMENTS, NOTES, CODES, ANDDIMENSIONS PRIOR TO THE START OF CONSTRUCTION AND SHALL NOTIFY THE ARCHITECT IFCONDITIONS VARY FROM THOSE SHOWN ON THE DOCUMENTS. DO NOT SCALE THE DRAWINGS.6.WHEN EXISTING CONSTRUCTION IS REMOVED, DISTURBED, DAMAGED, REPLACED OR RENOVATED INANY WAY, CONTRACTOR SHALL PROVIDE PATCHING, PAINTING AND MATERIALS OF SAME TYPE ANDQUALITY AS TO MATCH ADJACENT EXISTING SURFACES, UNLESS OTHERWISE NOTED.7.CONTRACTOR IS TO PROVIDE ALL BLOCKING, FURRING AND SHIMMING FOR INSTALLATION ANDCOMPLETION OF WORK.8.ALL NEW WORK SHALL BE PLUMB, LEVEL AND SQUARE. SCRIBE AND MAKE FIT ALL NEW WORK TOEXISTING.9.CONTRACTOR IS TO VERIFY ALL DIMENSIONS BEFORE ORDERING MATERIAL OR DOING WORK. NOEXTRA COMPENSATION OR CHARGES WILL BE ACCEPTED DUE TO DIFFERENCES BETWEEN THE ACTUALMEASUREMENTS AND MEASUREMENTS INDICATED ON THE DRAWINGS. DO NOT SCALE THE DRAWINGS.10.ALL DETAILS ARE SUBJECT TO CHANGE DUE TO EXISTING FIELD CONDITIONS. CONTRACTOR MUSTNOTIFY ARCHITECT OF SAME.11.CONTRACTOR TO COORDINATE ALL DOOR HARDWARE, TRIM AND FINISHES TO MEET INTENT ANDCOMPLIANCE.12.THESE DRAWINGS DO NOT PURPORT TO SHOW ALL ITEMS AND PROCEDURES REQUIRED FOR ACOMPLETE INSTALLATION. THE INTENT IS TO INDICATE THE GENERAL SCOPE OF THE PROJECT INTERMS OF THE GENERAL ARCHITECTURAL DESIGN CONCEPT, THE LOCATION/DIMENSIONS OF THECONSTRUCTION AND MAJOR ELEMENTS OF CONSTRUCTION.13.CONTRACTORS ARE RESPONSIBLE FOR OBTAINING AND PAYING FOR ALL PERMITS ASSOCIATED WITHTHE WORK OF THEIR CONTRACT.14.,7(06127('$6 %<2:1(5µ$5(72%()851,6+('$1',167$//('%<7+(2:1(5257+(2:1(5 6VENDOR.15.OWNER PROVIDED EQUIPMENT IS INDICATED FOR REFERENCE ONLY. COORDINATE AND VERIFYDIMENSIONS AND CLEARANCE REQUIREMENTS WITH ACTUAL EQUIPMENT PROVIDED.16.CONTRACTOR TO PROVIDE FIRE STOPPING AT ALL NEW PENETRATIONS MADE IN EXISTING AND NEWFIRE RATED CONSTRUCTION. REFER TO LIFE SAFETY PLANS.CONCRETE MASONRY UNITS(CMU)CEMENT, SAND, GROUT, PLASTER,OR GYPSUM WALL BOARDEARTHASPHALTCONCRETECARPETPLYWOODSTEELBATT. OR LOOSEINSULATIONRIGID INSULATIONABBREVIATIONSMATERIAL SYMBOLSREFERENCE SYMBOLS3INTERIOR ELEVATIONSHEET NODETAIL NO42X-XXX1BUILDING SECTIONEXTERIOR ELEVATIONWALL SECTION0X-XXXSHEET NODETAIL NODETAIL NOSHEET NOSHEET NOX-XXX0DETAIL NODETAIL REFERENCEMATCH LINESMATCH LINEXXXXXXXXXXXXXXELEV. = XXX'-XX"ELEVATIONCUT LINECENTER LINEROOM IDENTIFIERNAMEAREA (SF)ROOMDOOR IDENTIFIERWALL TYPE(REFER TO WALL TYPES FOR KEY)REVISION SYMBOL AND CLOUD1DRAWING TITLENORTH ARROWCLDEMOLITION WALL. G.C. TO PATCH ANDREPAIR EXISTING SURFACES TO REMAIN.PREP SURFACES FOR NEW FINISHESLINE INDICATES ITEM TO BEDEMOLISHED ON DEMO DRAWINGSUNLESS OTHERWISE NOTEDEXISTING WALL TO REMAINNEW STUD FRAMED WALLNEWDOOR MARKEXISTINGDOOR MARKA.EXISTING CONDITIONS ARE TAKEN FROM FIELD OBSERVATIONS AND PRIOR CONSTRUCTION DOCUMENTSWHEN AVAILABLE AND ARE NOT GUARANTEED. CONTRACTOR SHALL FIELD VERIFY ALL EXISTINGCONDITIONS PRIOR TO BID. NO ALLOWANCE WILL BE MADE FOR ADDITIONAL COSTS DUE TOCONTRACTORS FAILURE TO VERIFY EXISTING CONDITIONS AND DIMENSIONS.B.WHEN EXISTING CONSTRUCTION WHICH IS TO REMAIN IS DAMAGED DURING THE COURSE OFCONSTRUCTION AS A RESULT OF CONTRACTORS WORK, IT SHALL BE REPAIRED AND/OR REPLACED WITHSIMILAR OR LIKE MATERIALS, SUBJECT TO ARCHITECTS APPROVAL AND WITHOUT COMPENSATION.C.CONTRACTOR SHALL DISPOSE OF ALL DEMOLITION AND/OR OTHER WASTE MATERIALS, CAUSED BY THISCONSTRUCTION, OFF SITE IN A PROPER LEGAL MANNER.D.OWNER TO REMOVE, TEMPORARILY STORE AND RELOCATE EXISTING FURNITURE AND ALL EXISTING LOOSEEQUIPMENT ITEMS AS NECESSARY TO ACCOMMODATE DEMOLITION AND RENOVATION.E.COORDINATE DEMOLITION WORK WITH OWNER. OWNER HAS THE RIGHT OF FIRST REFUSAL FOR ALLSCHEDULED REMOVED MATERIALS.GENERAL DEMOLITION NOTESDEMOLITIONDOOR MARKA0C-6SCALEACTACOUSTICAL CEILING TILEADJADJACENTAFFABOVE FINISH FLOORAFGABOVE FINISH GRADEAHUAIR HANDLING UNITALUMALUMINUMALTALTERNATEAPPROXAPPROXIMATE (LY)AVGAVERAGEBLDGBUILDINGBOBOTTOM OFBSMTBASEMENTBURBUILT UP ROOFCFMCUBIC FEET PER MINUTECFMFCOLD FORMED METAL FRAMINGCJCONTROL JOINTCLGCEILINGCLRCLEARCIPCAST IN PLACECMUCONCRETE MASONRY UNITCOLCOLUMNCONCCONCRETECONTCONTINUOUSCPTCARPETCUCUBICDEMODEMOLISHDIADIAMETERDWGDRAWINGEC ELECTRICAL CONTRACTOREIFSEXTERIOR INSULATION FINISHSYSTEMELEVELEVATIONEPDMETHYLENE PROPYLENE DIENEMONOMERETREXISTING TO REMAINENGRENGINEEREQEQUALESTESTIMATEDEXIST, EXGEXISTINGEXTEXTERIORFINFINISH (EDFLFLOORFPCFIRE PROTECTION CONTRACTORFTFOOT OR FEETFURNFURNITUREFUTFUTUREGALVGALVANIZEDGCGENERAL CONTRACTORGYBGYPSUM WALL BOARDHCHEATING, VENTILATING AND AIRCONDITIONING CONTRACTORHMHOLLOW METALHVACHEATING, VENTILATING AND AIRCONDITIONINGHORIZHORIZONTALIDINSIDE DIAMETERININCHINSULINSULATIONINTINTERIORLIN FTLINEAL FOOT OR FEETLOCLOCATIONMAXMAXIMUMMFGMANUFACTURERMEMATCH EXISTINGMECHMECHANICALMINMINIMUMMISCMISCELLANEOUSMOMASONRY OPENINGMTDMOUNTEDMTGMOUNTINGNANOT APPLICABLENICNOT IN CONTRACTNRCNOISE RESISTANCE COEFFICIENTNTSNOT TO SCALEOCON CENTEROD OUTSIDE DIAMETEROHOVERHEADOPPOPPOSITE HANDOFCIOWNER FURNISHED CONTRACTORINSTALLEDPCPLUMBING CONTRACTORPLAMPLASTIC LAMINATEPLBGPLUMBINGPRPAIRPTPRESSURE TREATEDPVCPOLYVINYL CHLORIDEQTYQUANTITYRDROOF DRAINREFREFERENCEREQREQUIREDROROUGH OPENINGROWRIGHT OF WAYRTUROOF TOP UNITSIMSIMILARSPECSPECIFICATIONSQ FTSQUARE FOOTSQ INSQUARE INCHSSSTAINLESS STEELSTDSTANDARDTBDTO BE DETERMINEDTEMPTEMPORARYTOTOP OFTPOTHERMOPLASTIC POLYOLEFINTYPTYPICALULUNDERWRITER'S LABORATORYUNOUNLESS NOTED OTHERWISEVCTVINYL COMPOSITION TILEVERTVERTICALVIFVERIFY IN FIELDVOLVOLUMEW/WITHW/OWITHOUTMECEILING HEIGHT, AFF UNLESSNOTED OTHERWISEGENERAL PARTITION NOTES1. PARTITION EXTEND TO BOTTOM OF DECK AS NOTEDAABBX-XXX0118"=1'-0"EXISTING CEILING7'-9" A.F..F.BOTTOM OF DECK9'-5 1/2" A.F..F.3 1/2" SOUNDATTENUATION BATT.3 5/8" x 20 GA. METAL STUDS @16" o.c. ON EXISTING CONCRETEWALL REF. SPEC. 0922163 1/2" SOUND ATTENUATION BATT.3 5/8" METAL DEFLECTION TRACKANCHORED TO DECKACOUSTICAL SEALANT BOTH SIDES, TYP.SUSPENDED CEILINGM2FIN. FLOORM2A-00113 5/8" METAL STUDS @ 16" O.C. CLAD W/ ONE LAYER 5/8" GYP. BD. ON BOTH SIDES& SOUND ATTENUATION BLANKETS UP TO UNDERSIDE OF DECK/STRUCTURE ABOVE.EXISTING CONCRETE WALLTO REMAIN“),(/'9(5,)<EXISTING CEILINGFIELD VERIFYSUSPENDED CEILINGALIGN FINISHED GYP. BD.W/FACE OF FISHED WALL BELOWPAINT TO MATCH EXISTING (RED)STAIRBREAKROOM5/8" IMPACT RESISTANTGYPSUM BOARD5/8" GYPSUM BOARD WALL FINISHAND PAINT TO MATCH EXISTING5/8" IMPACT RESISTANTGYP. BD. WALL FINISH ANDPAINT TO MATCH EXISTINGA-001 DRAWING LIST, SYMBOLS & DETAILSA-101 FIRST AND SECOND FLOOR EXITING PLANSA-102 SECOND FLOOR PARTIAL PLANA-103 THIRD FLOOR PLANS AND DETAILSDRAWING LISTA-001EJMAANDRAWING NAME:DRAWING NUMBER:DATE:ISSUED FOR:DRAWN BY:REVIEWED BY:PROJECT NUMBER:THE CORNELL STORE‹/D%HOOD$VVRFLDWHVREVISIONSNO:DATE:DESCRIPTION:Date & Time: 5/4/2017 10:15 AM By: Marchenkoff, EmilyPath: \\PROJECTS1\ProjectsAM-4\Cornell University\2170675 - Cornell Store\Drawings\Arch\A-001 DRAWING LIST AND DETAILS.dwg ---KEY PLANSCALE: NTS EXITPATHEXITPATHEXITPATHEXITPATHEXITPATHEXITPATHEXITPATHEXIT PATH A-101EJMAANDRAWING NAME:DRAWING NUMBER:DATE:ISSUED FOR:DRAWN BY:REVIEWED BY:PROJECT NUMBER:THE CORNELL STORE‹/D%HOOD$VVRFLDWHVREVISIONSNO:DATE:DESCRIPTION:Date & Time: 5/4/2017 10:14 AM By: Marchenkoff, EmilyPath: \\PROJECTS1\ProjectsAM-4\Cornell University\2170675 - Cornell Store\Drawings\Arch\A-101 FIRST AND SECOND FLOOR EXITING PLANS.dwg ---A-1011FIRST FLOOR EXITING PLANSCALE: 1/16" = 1'-0"A-1012SECOND FLOOR EXITING PLANSCALE: 1/16" = 1'-0"NCHAPTER 3 - USE AND OCCUPANCY CLASSIFICATION:MERCANTILE - GROUP MSECTION 309 CHAPTER 5 - GENERAL BUILDING CODE HEIGHTS AND AREAS:ALLOWABLE BUILDING HEIGHTTABLE 504.45 STORIES 2 STORIESALLOWABLE BUILDING AREAS TABLE 506.264,500 SF37,789 SF(SPRINKLERED)CHAPTER 6 - TYPES OF CONSTRUCTIONCONSTRUCTION CLASSIFICATIONSECTION 602TYPE IIATYPE IIAFIRE RESISTANCE RATING REQ. FOR BUILDING ELEMENTSSTRUCTURAL FRAMETABLE 6011 HREXISTINGBEARING WALLS - EXTERIOR/INTERIORTABLE 6011 HREXISTINGNONBEARING WALLS - EXTERIOR/INTERIORTABLE 6010 HREXISTINGFLOOR CONSTRUCTIONTABLE 6011 HREXISTINGROOF CONSTRUCTIONTABLE 6011 HREXISTINGCHAPTER 7 - FIRE RESISTANCE - RATED CONSTRUCTIONFIRE BARRIERS TABLE 706.42 HREXISTINGFIRE PARTITIONSSECTION 708.31 HREXISTINGSMOKE BARRIERSSECTION 709.31 HREXISTINGCHAPTER 8 - INTERIOR FINISHESEXIT ENCLOSURES AND EXIT PASSAGEWAYSTABLE: 803.11CLASS B (SPRINKLERED)CORRIDORSTABLE: 803.11CLASS CROOMS AND ENCLOSED SPACESTABLE: 803.11CLASS CCHAPTER 9 - FIRE PROTECTION SYSTEMSAUTOMATIC SPRINKLERSECTION: 903.2.7 AUTO-SPRINKLERED COMPLIESPORTABLE FIRE EXT.SECTION: 906REQUIRED EXISTING 75' TRAVEL DISTANCEFIRE ALARM (MANUAL)SECTION: 907REQUIREDEXISTINGFIRE CODE OF IBCCHAPTER 10 - MEAN OF EGRESSOCCUPANT LOADSECTION 1004---------MERCANTILETABLE: 1004.1.260 GROSS-----STORAGE/STOCK/SHIPPING AREAS300 GROSS-----DOORS: WIDTHSECTION: 1010.1.132" MIN. CLEAR36" MIN.SWINGSECTION: 1010.1.2.1SEE COMMENTPROVIDEDIN DIRECTION OF EXIT SERVINGOCCUPANT LOAD OF 50 OR MORE.PANIC AND FIRE EXIT HARDWARESECTION: 1010.1.10REQUIREDCOMPLIESEXIT ACCESSSECTION: 1017----------TRAVEL DISTANCESECTION: 1017.2250 FEETCOMPLIES(SPRINKLERED)EXITS AND EXIT ACCESS DOORWAYSSECTION: 10062 EXITSCOMPLIESCHAPTER 11 - ACCESSIBILITYACCESSIBLE ROUTE: CONNECTED SPACESSECTION: 1104.31 MIN.COMPLIESACCESSIBLE ENTRANCESSECTION: 110560% MIN.EXISTINGBUILDING CODE - IBC 2015 REQUIRED\CODE ITEMS:CODE SECTION:ALLOWEDACTUALCOMMENTSCode Compliance of Work ScopeNew work shall comply with provisions of the 2015 International Existing Building Code (IEBC), 2016 NYSSupplements to the NYS Energy Conservation Code (NYSECC) Revised August 2016 in addition to the 2014Draft Edition of the NYSED Manual of Planning Standards.A)Classification of Work - Chapter 5 (2015 IEBC)Section 503 - Alteration - Level 1503.1- Scope. Level 1 Alterations include the removal and replacement or the covering of existingmaterials, elements, equipment, or fixtures using new materials, elements, equipment or fixturesthat serve the same purpose.B)C)Compliance RequirementsCommentsChapter 7 - Alterations - Level 1Section 702503.2- Application. Level 1 Alterations shall comply with provisions of Chapter 7.702.1. Interior FinishesAll newly installed wall and ceiling finishes shall comply with Chapter 8 of theInternational Building Code.Section 504 - Alteration - Level 2504.1- Scope. Level 2 Alterations include the reconfiguration of space, the addition or elimination ofany door or window, the reconfiguration or extension of any system, or the installation of anyadditional equipment.504.2- Application. Level 1 Alterations shall comply with provisions of Chapter 7 for Level 1Alterations as well as the provisions of Chapter 8.Chapter 8 - Alterations - Level 2Section 808 Electrical808.1.All newly installed electrical equipment and wiring relating to workdone in anyarea shall comply with applicable requirements of NFPA 70.Occupancy loadunchanged.Existing electrical equipment tobe reinstalled. REF FIRE DOOR NOTESEXISTING DOOR & FRAME TO REMAINTUNNELSTORAGEFIRE DOOR NOTES:1. PROVIDE SHIMS AT HINGE SIDE OF DOOR TO ADJUST DOOR/FRAME GAP TO BE EQUAL AT HINGEAND LATCH SIDES OF DOOR. SHIMS SHALL BE 16 GAUGE (116") STAINLESS STEEL PEEL AND STICK(STACKABLE) IN COMPLIANCE WITH NFPA 80, SECTION 6.4.3.4 SHIMS AVAILABLE AT FIRE DOORSOLUTIONS, 855-714-3473, WWW. FIREDOORSULUTIONS.COM2. REMOVE EXISTING PULL HANDLE. PATCH SCREW HOLE WITH FIRE-RATED THRU-BOLTS, MALE &FEMALE APPLICATIN 14" WIDTH IN COMPLIANCE WITH NFPA 80, SECTION 5.2.15.4 BOLTS AVAILABLEAT FIRE DOOR SOLUTIONS,855-714-3473, WWW. FIREDOORSULUTIONS.COM3. PROVIDE NEW MORTISE LOCKSET, SARGENT 8237 LNL 26D OR APPROVED EQUAL, STANDARDSERIES, CLASSROOM FUNCTION LEVEL HANDLE. CONTRACTOR TO VERIFY COMPATIBILITYW/EXISTING FIRE DOOR. NOTIFY OWNER IMMEDIATELY OF NON-COMPATIBILTY.NOTE: CONTRACTOR TO CONTACT OWNER WHEN FIRE DOOR WORK IS COMPLETE FOR NFPA 80 TESTING.A-102EJMAANA-1021SECOND FLOOR PLANSCALE: 14" = 1'-0"DRAWING NAME:DRAWING NUMBER:DATE:ISSUED FOR:DRAWN BY:REVIEWED BY:PROJECT NUMBER:THE CORNELL STORE‹/D%HOOD$VVRFLDWHVREVISIONSNO:DATE:DESCRIPTION:Date & Time: 5/4/2017 10:16 AM By: Marchenkoff, EmilyPath: \\PROJECTS1\ProjectsAM-4\Cornell University\2170675 - Cornell Store\Drawings\Arch\A-102 SECOND FLOOR PLAN.dwg ---KEY PLANNTSAREA OF WORK REMOVE & PRESERVE FORREINSTALLATION EXISTING OUTLETS,WIRE MOLD, SWITCHES, FIRE ALARM,THERMOSTAT, ETC.METAL STUDWOOD STUDREMOVE & PRESERVE EXISTINGDOOR, FRAME AND HARDWAREFOR REINSTALLATIONLINE OF TEMPORARYCONST. BARRICADE2X4 WOOD STUD WITH12" PLYWOOD FLOORTO CEILINGREMOVE & PRESERVE FORREINSTALLATION EXISTINGOUTLETS, AND WIRE MOLDOWNER TO REMOVE WALL & BASE CABINETS,COUNTERTOPS & WALL MOUNTED SHELFAND STORE FOR CONTRACTOR TO REINSTALLDNTMAINTAIN THIS SIDE OFSTAIR AND EXIT PATHSECURE ONE PAIR INTERIOR DOORSDURING CONSTRUCTION.OWNER TO PROVIDE SIGNAGE INDICATING TEMP.CLOSURE OF THE DOORSTO REMAINTO BE REMOVEDA-10343'x7'x12" PLYWOOD DOORWITH HASP FORPAD LOCK44EXISTING CEILING TO BE REMOVEDAND REINSTALLEDAS REQUIRED FORWALL CONSTRUCTIONEXISTING CEILING TOBE REINSTALLED* PROVIDE NEW WALLEDGE TRIM AND GRID T'SAS REQUIRED (TYPICAL)EXISTING CEILING TO BE REMOVEDAND REINSTALLEDAS REQUIRED FORWALL CONSTRUCTIONEXISTING LIGHTING TO REMAINEXISTING MECH EQUIPTO REMAINEXISTING LIGHTING TO REMAINEXISTING MECH EQUIPTO REMAINSUPPLY AIR GRILLETO REMAINREINSTALL 2 CABINETSREINSTALL COUNTERTOPM1M2M2PAINT ENTIRE WALL REDTO MATCH EXISTINGLOGO BY OWNERPAINT ENTIRE WALL BOTH SIDESWHITE TO MATCH EXISTINGDNTA-1036A-1035REINSTALL OUTLETS, WIRE MOLD,SWITCHES, FIRE ALARM,THERMOSTAT, ETC.REINSTALL OUTLETS,AND WIRE MOLDREINSTALL CABINETS,COUNTERTOP AND SHELFPAINT ENTIRE WALLTO MATCH EXISTINGREINSTALL DOOR, FRAMEAND HARDWAREFIN FLOOREXISTING CONCRETE WALLTO REMAINNEW WOOD TRIM TOMATCH EXISTINGREINSTALL STORAGECABINETSNEW METAL STUD & 58" GYP. BD. WALLSOUND ATTENUATIONBATT INSULATIONNEW WOOD BLOCKINGAS REQUIREDALIGN FINISHED GYP. BD.W/EXISTING FINISHEDWALL BELOW. PAINT TOMATCH EXISTING (RED)IMPACT RESISTANTGYPSUM BOARDFIN FLOOREXISTING CONCRETE WALLTO REMAINOWNER WILL REMOVEEXISTING COUNTERTOP ANDSTORE FOR REINSTALLATIONBY CONTRACTOROWNER WILL REMOVE EXISTINGCABINETS FOR WALLDEMOLITION, AND STORE FORREINSTALLATION BYCONTRACTORREMOVE WOOD STUD &GYP. BD. WALL REMOVE &SALVAGE WIRE MOLD FORREINSTALLATIONFIN FLOORREINSTALL COUNTERTOPW/WD BLOCKING AS REQUIREDREINSTALL WIRE MOLDALIGN FINISHED GYP. BD.W/EXISTING FINISHEDWALL BELOW. PAINT TOMATCH EXISTING (RED)IMPACT RESISTANTGYPSUM BOARDNEW METAL STUD &58" GYP. BD. WALLEXISTING CONCRETEWALLTO REMAINROOM FINISH NOTESBREAKROOMFINISH/ MATERIALFLOOREXISTING TO REMAIN BASE4" RUBBER BASE *CEILINGACT TO REMAINNOTES:CONTRACTOR TO PATCH AND MATCH ALL DISTURBEDSURFACES. REF. A-001 GENERAL DEMOLITION NOTES* NEW RUBBER BASE TO MATCH EXISTINGSTAIRFINISH/ MATERIALFLOOREXISTING TO REMAIN WALL PAINT: TO MATCH EXISTINGBASE4" RUBBER BASE *CEILINGACT TO REMAINWALL PAINT: TO MATCH EXISTINGA-103EJMAAA-1031THIRD FLOOR DEMOLITION PLANSCALE: 1/4" = 1'-0"DRAWING NAME:DRAWING NUMBER:DATE:ISSUED FOR:DRAWN BY:REVIEWED BY:PROJECT NUMBER:THE CORNELL STORE‹/D%HOOD$VVRFLDWHVREVISIONSNO:DATE:DESCRIPTION:Date & Time: 5/4/2017 10:17 AM By: Marchenkoff, EmilyPath: \\PROJECTS1\ProjectsAM-4\Cornell University\2170675 - Cornell Store\Drawings\Arch\A-103 THIRD FLOOR PLAN.dwg ---NKEY PLANNTSAREA OF WORKA-1033THIRD FLOOR REFLECTED PLANSCALE: 1/4" = 1'-0"A-1033THIRD FLOOR PLANSCALE: 1/4" = 1'-0"A-1034WALL DEMOLITION SECTIONSCALE: 1" = 1'-0"A-1035WALL SECTION AT COUNTERTOPSCALE: 1" = 1'-0"A-1036WALL SECTION AT WALL CABINETSSCALE: 1" = 1'-0"NOTE: * CHECK WITH OWNER FOR SPARE CEILING PANELS IN STOCKFIELD VERIFY ALL EXISTING DIMENSIONSFIELD VERIFY ALL EXISTING DIMENSIONSOWNER TO REMOVE AND STORE ITEMS FOR CONTRACTOR TO REINSTALL * TWO SECTIONS OF WALL CABINETS * WALL COUNTER * TWO SECTIONS OF FLOOR CABINETS AND COUNTERS * WALL SHELF** FLAT SCREEN TV - OWNER TO REINSTALLNOTE: