HomeMy WebLinkAbout_Conformed Set Volume 1 80GENERAL NOTES:
1. THE FOLLOWING ASBESTOS CONTAINING / ASBESTOS CONTAMINATED MATERIALS ARE NOT SHOWN BUT SHALL BE REMOVED AT
ALL LOCATIONS WHERE PRESENT AT THE PENTHOUSES AND ROOF SECTIONS:
A. DOOR SLABS WITH ASSUMED ASBESTOS CONTAINING CORE MATERIAL. REFERENCE DRAWING AD -0160 FOR PENTHOUSE
DOORS TO BE REMOVED. REFERENCE DRAWING AR -0000 NOTE 7-G FOR ABATEMENT INFORMATION AND REQUIREMENTS.
B. TAR COATING PRESENT ON PENTHOUSE CMU WALLS BENEATH LLENROC CLADDING. THIS WORK IS TO BE PERFORMED AS A
PART OF ADD ALTERNATE 1 AND SHALL INCLUDE THE REMOVAL OF THE TAR COATING WITH THE POTENTIAL TO BE IMPACTED
BY THE LLENROC CLADDING REMOVAL.
LEGEND AND KEYED NOTES
SYMBOL
MATERIAL/ITEM TO BE REMOVED
ASBESTOS CONTAINING REPAIR TAR AT TERMINATION BAR TO BE REMOVED
PENTHOUSE I ROOF LEVEL ABATEMENT PLAN
SCALE: 3/32" =1'-0"
NORTH
0 5'-4" 10'-8"
SCALE: 3/32" = 1'-O"
21'-4"
Cornell University
Facilities Services
102 Humphreys Service Building
Ithaca, NY 14853
No.1 Revision
Project Name
' Date
UPSON HALL RENOVATION
CORNELL UNIVERSITY
124 HOY ROAD, ITHACA, NY 14850
ITHACA
Seal
NEW YORK
ADELTA
ENGINEERS, ARCHITECTS, & LAND SURVEYORS
860 Hooper Road
Endwell, New York 13760
Tel: 607.231.6600
Fax: 607.231.6651
Email: mail@deltaengineers.com
Web: www.deltaengineers.com
Scale
AS SHOWN
Project No.
2015.030.059
UNAUTHORIZED ALTERATION OF THIS
DRAWING IS A VIOLATION OF THE
NEW YORK STATE EDUCATION LAW,
SECTION 7209, SUBDIVISION 2.
Date
03/24/2015
Drawing Title
PENTHOUSE / ROOF
LEVEL ABATEMENT PLAN
Drawing No.
AR -0007
x