HomeMy WebLinkAbout_Conformed Set Volume 1 8UP122345688910111213141516171819206.18.18.910.12.6ABCDEFGHJKLMNPQORSTQ.1Q.6R.320.22FB2FB 2FB2FB2FB2FB2FB 2FB2FB2FB2FB 2FB2FB2FB 2FB2FB2FB2FB2FB2FB2FB 2FB2FB2FB2FB2FB2FB2FB2FB2FB2FB2FB2FB2FB2FB2FB2FB2FB2FB2FB2FB2FB2FB2FB77 SFElev P.0MechanicalSprinkler ValveGeneratorMechanical1517 SFUpson Automotive Lab (Existing)196 SFEgress Stair S134 SFElev F.0Shaft211 SFCorridor921 SFLoading DockGM Auto Lab186 SFDrop Tower BaseUniversal Waste - HoldingRapid Prototyping Lab96 SFShaft89 SFAreaway90 SFAreaway231 SFEgress Stair W196 SFEgress Stair NTeams Pod Build AreaTeam Conference62 SFCustodialTeams Pod Design Area184 SFToiletsTeams Pod Design AreaStaff Office133 SFExhibitionTelecom1649 SFSouth Corridor1163 SFWest Corridor167 SFWest VestibuleEmerson Manufacturing Teaching Lab250 SFWomen184 SFMenCAD/CAM LabStudent Orgs. Office23 SFCustodial479 SFMDF (EXISTING)STAIR247270 54"50"1FB1FB 1FB 1FB2FB2FB2FB2FB 2FB1FB1FBDOOR130220 33"20"STAIR287310 62"57"DOOR172220 33"32"STAIR247270 54"50"EXIT2FB 2FB2FBElecElecStaff Office Storage2FB2FB2FB2FBEXITTHIS IS NOT ANEGRESS DOORProjects StorageEXIT2FB 2FB2FB2FB2FB2FB 2FB2FB2FB 2FBR.520.3R.4763 SF16 OCC.B50-BUSINESS900 SF4 OCC.S2300-STORAGE408 SF2 OCC.S2300-STORAGE210 SF1 OCC.S2300-STORAGE357 SF18 OCC.B20-BUSINESS4638 SF93 OCC.A350-ASSEMBLY269 SF18 OCC.B15-BUSINESS320 SF2 OCC.S2300-STORAGE154 SF1 OCC.S2300-STORAGE187 SF1 OCC.S2300-STORAGE433 SF29 OCC.A315-ASSEMBLY186 SF1 OCC.B300-BUSINESS122 SF2 OCC.B100-BUSINESS107 SF1 OCC.B300-BUSINESS128 SF2 OCC.B100-BUSINESSB -BUSINESS2233 SF50 58 OCC.1FB1FB1FB1517 SF31 OCC.B50-BUSINESS5039 SF102 OCC.GRUMMAN5042 SF1 OCC.B300-BUSINESS162 SF1 OCC.B300-BUSINESSTHIS IS NOT ANEGRESS DOORDOOR172220 33"32"DOOR100453 68"32"CONTROL AREABOUNDARYDOOR51220 33"32"TOTAL DISTANCE176'-11" < 250'-0"TOTAL DISTANCE152'-1" < 250'-0"TOTAL DISTANCE155'-1" < 250'-0"TOTAL DISTANCE114'-0" < 250'-0"FEC1FB 1FB227 SF1 OCC.B300-BUSINESS698 SF14 OCC.B50-BUSINESS508 SF34 OCC.B15-ASSEMBLYUPUPFEC46 SFVendingCORR224360 54"34"DOOR165220 33"32"DOOR224260 39"34"744 SF55 OCC.A315-ASSEMBLY485 SF33 OCC.A315-ASSEMBLY493 SF33 OCC.A315-ASSEMBLY1111 SF80 OCC.A315-ASSEMBLY534 SF39 OCC.A315-ASSEMBLY137 SF2 OCC.B100-BUSINESS279 SF19 OCC.B15-BUSINESS333 SF23 OCC.B15-BUSINESSTeams Pod Design AreaTeams Pod Build AreaTeams Pod Design AreaTeams Pod Build AreaTeams Pod Design AreaTeam ConferenceTeam ConferenceSwanson DirectorElec459090909090909090452FB 2FB2FB2FB9027' - 4"CORRIDOR COMPLIESWITH SECTION 1017.3:LENGTH OF DEAD END ISLESS THAN 2.5 TIMES THELEAST WIDTH OF THEDEAD END. ALLOWABLEDISTANCE = 34'-9"2FBDOOR ON HOLD OPENTO ADDRESS DEADEND CORRIDORCONDITION321 SF2 OCC.S2300-STORAGEShower Room90CRCRCRCRCRCRCRCRCRCRCRCONTROL AREA BOUNDARYCONTROL AREA BOUNDARYCONTROL AREABOUNDARYFVCFECCRCR2FB 2FB2FB1FB 1FB1FB1FB1FBEXISTINGDRINKINGFOUNTAIN268 SF1 OCC.S2300-STORAGE117 SF3 OCC.B50-BUSINESS134 SF3 OCC.B50-BUSINESSEngine Room Shock TestingComposites FabricationSheet Metal FabricationFE1FB1FB 1FB2FBCRCRCR2FBNO EGRESS2FB2FB2FBFEC1FB1FB1FB1FBStorage74 SF1 OCC.B300-BUSINESSM4545284 SFLab Support1FB1FB1FB1FB 1FB1FB1FB1FB1FB 1FB1FB2FB2FB2FB2FB 2FB2FB2FB2FB2FB2FB2FB2FB2FB2FB2FB2FBMAINTAIN EXISTINGFIRE RATEDSEPARATIONVENTILATEDSPRAY PAINTBOOTH18' - 0 1/4"5' - 9 1/2"2FB2FBPARTITION RATINGS DESIGNATIONS3-HOUR FIRE BARRIER2-HOUR FIRE BARRIER1-HOUR FIRE BARRIER1-HOUR SMOKE BARRIERDOOR SYMBOLSEXIT SIGNAGEPATH OF TRAVELLIFE SAFETY EGRESS SYMBOL3FB2FB1FBSB140240 72"44"CORRACTUAL CUMULATIVEPOPULATIONWIDTH REQ'D BY CODEBASED ON ACTUALCUMULATIVEPOPULATIONACTUAL WIDTHPROVIDEDPOPULATION PERMITTEDBASED ON WIDTHPROVIDED3FB2FB1FBSBNOTE: S-1 AND S-2 OCCUPANCIES ARE LIMITED TO 10% OFTHE FLOOR AREA AND ARE CONSIDERED ACCESSORYSPACES.FIRE PROTECTION EQUIPMENTFEC10'-0" <250'-0"SEMI-RECESSED FIREEXTINGUISHER CABINETFVCTRAVEL DISTANCE< REQ'D DISTANCEEXITSURFACE MOUNTED FIREDEPARTMENT VALVE CABINET WITHFIRE DEPARTMENT VALVE AND 10#ABC FIRE EXTINGUISHER.OCCUPANCY CLASSIFICATIONSLIFE SAFETY LEGENDA3-ASSEMBLY3,557 SF20 178 OCC.OCCUPANCY GROUPAREATOTAL OCCUPANTSOCCUPANT LOAD FACTORCREXIT DOORACCESS CONTROL DOORSEQUIPPED WITH CARD READERWALL MOUNTEDCLG MOUNTEDBRACKET MOUNTED FIREEXTINGUISHER.FEFECSURFACE MOUNTED FIREEXTINGUISHER CABINETFVCSEMI-RECESSED FIREDEPARTMENT VALVE CABINET WITHFIRE DEPARTMENT VALVE AND 10#ABC FIRE EXTINGUISHER.MACCESS CONTROL DOORSEQUIPPED WITH DOOR MONITORFIRE SERVICE PHONE01/2"1"2"SheetTitleApprovedCheckedDrawnJob NumberDateSheet InformationRevisionsMEP FPME Engineers29 West 38th Street, 5th FloorNew York, NY 10018t 212.447.6770f 212.447.6615STRUCTURAL ENGINEER/SUSTAINABILITY CONSULTANTThornton Tomasetti51 Madison Ave.New York, N.Y. 10010t 917.661.7800f 917.661.7801LIGHTING CONSULTANTLumen Architecture214 W 29th Street Suite 1005New York, NY 10001t 212.564.6469f 917.591.2524LANDSCAPE ARCHITECTTrowbridge Wolf Michaels1001 West Seneca Street Suite 101Ithaca, NY 14850t 607.277.1400f 000.000.0000162345AEBCD162345AEBCDCopyright © 2013 Perkins+Will227 West 29th Street, 7th Flr.New York, NY 10001t: 212 505-5955f: 212 505-1648CIVIL ENGINEERTG Miller PC203 North Aurora StreetIthaca, NY 14850t 607.272.6477f 607.273.6322AV / ACOUSTICSThe Sextant Group244 Madison Avenue Suite 311New York NY 10016t 877.684.2311f 412.323.8538CODE CONSULTANTCode Consultants ProfessionalEngineers, PC215 West 40th Street 15th FloorNew York, NY 10018t 212.216.9596f 212.216.96193/31/2015 4:22:13 PMc:\temp\Upson Hall _ ARCH_sobeskic.rvtLS-0100LEVEL 00 LIFESAFETY OVERALLCASAHS031549.00002/27/2015RWGUpson HallRenovation124 Hoy Rd, Ithaca, NY 14850CornellUniversity 3/32" = 1'-0"1LEVEL 00 LIFE SAFETY OVERALL215 Park Avenue South4th FloorNew York, NY 10003t 212.251.7000f 212.251.7111www.perkinswill.comNOTE: NO SCOPE AT GRUMMAN. HALF OF GRUMMANOCCUPANTS EXIT THROUGH UPSON. VERIFY EXIT INGRUMMAN MEETS CODE REQUIREMENTS.REQUIRED:WATER CLOSETLAVATORIESMALEFEMALEMALEFEMALEDRINKINGFOUNTAINSBATHTUBS ORSHOWERSSERVICE SINKPLUMBING CODE CALCULATIONSOCCUPANTS: 349(175 MALE 175 FEMALE)OCCUPANCY: ASSEMBLY - A-31.001.002.691.401.00REQUIRED:DRINKINGFOUNTAINSBATHTUBS ORSHOWERSSERVICE SINKWATER CLOSETLAVATORIESMALEFEMALEMALEFEMALEOCCUPANTS: 350(175 MALE 175 FEMALE)1OCCUPANCY: Business - B13.193.194.504.503.50OCCUPANCY LOAD - LEVEL 00Name AreaOccupancyFactorOccupantsA3Emerson Manufacturing Teaching Lab 4,638 SF 50 93Teams Pod Build Area 1,111 SF 15 75Teams Pod Build Area 744 SF 15 50Teams Pod Design Area 433 SF 15 29Teams Pod Design Area 493 SF 15 33Teams Pod Design Area 485 SF 15 33Teams Pod Design Area 534 SF 15 36349BCAD/CAM Lab 357 SF 20 18Composites Fabrication 789 SF 50 16Drop Tower Base 186 SF 300 1Engine Room 117 SF 50 3GM Auto Lab 1,738 SF 50 35Projects Storage 42 SF 300 1Rapid Prototyping Lab 763 SF 50 16Sheet Metal Fabrication 329 SF 50 7Shock Testing 134 SF 50 3Staff Office 128 SF 100 2Staff Office 122 SF 100 2Storage 107 SF 300 1Storage 74 SF 300 1Student Orgs. Office 162 SF 300 1Swanson Director 137 SF 100 2Team Conference 269 SF 15 18Team Conference 333 SF 15 23Team Conference 279 SF 15 19Teams Pod Build Area 698 SF 50 14Teams Pod Design Area 508 SF 15 34Telecom 227 SF 300 1Upson Automotive Lab (Existing) 1,517 SF 50 31249S2Elec 210 SF 300 1Elec 408 SF 300 2Elec 321 SF 300 2Generator 268 SF 300 1Mechanical 900 SF 300 4Mechanical 320 SF 300 2Sprinkler Valve 154 SF 300 1Universal Waste - Holding 187 SF 300 114TOTAL 612TOTAL REQUIRED:651855TOTAL PROVIDED:*Per IPC 410.1, Water Coolers with Bottled Water Dispensers shall be permitted to be substituted for notmore than 50 percent of the required drinking fountains.Refer to IBC Chapter 29 and Table 29-A "Minimum Plumbing Fixtures" for specifics, exceptions, andfootnotes.137*17851GRUMMAN LEVEL 00Grumman Labs 5039 SF 50 101726TOTAL OCCUPANTS:1100TOTAL EXIT CAPACITY:NO ISSUE DATE1 100% DD DOCUMENTS 14/08/282 50% CONSTRUCTIONDOCUMENTS14/11/073 BID SET 15/02/274 ADDENDUM NO 3 15/03/31