Loading...
HomeMy WebLinkAbout_Conformed Set Volume 1 77wi•PiPP iiiiiiiiiiiI iiiiiiiiiiiii'•••••••L 444444444144,11444440414444041,44•114•110044444•11, 1 I NO 1081 I IA0 I WOO IWO I 1.81 I I 1.41081 1101W01481 10881 1110081 11081 111 1.41081 I I IV I 44 1411 VOW 11.410.81•••••••••••••••••••••••••••••••• 141100#001 IWO 10.1101 DUFF ELD ALE. UPSON EA 26 11 114:451".4 pH ipsii#004 4 ,,•:.147,07orell; Pm_As 11 ik• • 1) . 0 • irall4;71:11.0 • • lea 4 % 1 rt. itoo..4:::::1111:11;:*a fi r *Mos IAA) 111.011 I Pi 01. OA ) 00111 eitS ••41$14 *V 11. 30B 303 300LA 340 GENERAL NOTES: 1. THE FOLLOWING ASBESTOS CONTAINING / ASBESTOS CONTAMINATED MATERIALS ARE NOT SHOWN BUT SHALL BE REMOVED AT ALL LOCATIONS WHERE PRESENT ON THE 3RD FLOOR: A. WALL MOUNTED BOARDS AND THEIR ASSOCIATED MASTIC/ADEHSIVE. REFERENCE DRAWING AR -0000 NOTE 7-F FOR ABATEMENT INFORMATION AND REQUIREMENTS. B. DOOR SLABS WITH ASSUMED ASBESTOS CONTAINING CORE MATERIAL. REFERENCE DRAWING AD -0130 FOR 3RD FLOOR DOORS TO BE REMOVED. REFERENCE DRAWING AR -0000 NOTE 7-G FOR ABATEMENT INFORMATION AND REQUIREMENTS. C. SINK BRACE MASTIC. REFERENCE DRAWING AR -0000 NOTE 7-J FOR ABATEMENT INFORMATION AND REQUIREMENTS. D. WINDOWS/ WINDOW SYSTEMS. REFERENCE DRAWING AR -0000 NOTE 7-P FOR ABATEMENT INFORMATION AND REQUIREMENTS. E. CURTAIN WALL SYSTEM. REFERENCE DRAWING AR -0000 NOTE 7-Q FOR ABATEMENT INFORMATION AND REQUIREMENTS. 2. ASBESTOS CONTAINING FLOOR TILE (VAT) SHOWN ON DRAWING AR -0004 REPRESENTS THE CONFIRMED LOCATIONS OF VAT AND MAY NOT REPRESENT ALL LOCATIONS WHERE VAT IS PRESENT ON THE 3RD FLOOR. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REMOVAL OF ALL 9" X 9" FLOOR TILE PRESENT ON THE 3RD FLOOR. REFERENCE DRAWING AR -0000 NOTE 7-A FOR ADDITIONAL VAT ABATEMENT INFORMATION AND REQUIREMENTS. 3. ASBESTOS CONTAINING PIPE AND PIPE FITTING INSULATION (TSI) SHOWN ON DRAWING AR -0004 REPRESENT THOSE 3RD FLOOR SPACES WHERE THE MATERIAL IS CONFIRMED TO BE PRESENT. TSI IS ALSO ASSUMED TO BE PRESENT IN CONCEALED WET -WALLS, PIPE CHASES, AND HARD CEILING PLENUM SPACES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REMOVAL OF ALL ASBESTOS CONTAINING PIPE AND PIPE FITTING INSULATION PRESENT ON THE 3RD FLOOR. REFERENCE MECHANICAL DEMOLITION DRAWINGS MD -2003A / MD2003B AND PLUMBING DEMOLITION DRAWING PD -2003 FOR EXISTING 3RD FLOOR PIPING LOCATIONS. REFERENCE DRAWING AR -0000 NOTE 7-B FOR ADDITIONAL TSI ABATEMENT INFORMATION AND REQUIREMENTS. LEGEND AND KEYED NOTES SYMBOL MATERIAL/ITEM TO BE REMOVED 0 SPACE / ROOM / AREA WITH CONFIRMED ASBESTOS CONTAINING PIPE / PIPE FITTING INSULATION TO BE REMOVED V /IIA STAIRWELL/CORRIDOR DOOR WITH ASBESTOS CONTAINING WINDOW GLAZING COMPOUND. ENTIRE DOOR/SIDE-LIGHT TO BE REMOVED LOCATION OF CONFIRMED ASBESTOS CONTAINING FLOOR TILE TO BE REMOVED ASBESTOS CONTAMINATED 1' X 1' CEILING TILE AND ASSOCIATED ASBESTOS CONTAINING MASTIC TO BE REMOVED NOT IN CONTRACT KEYED NOTES LEGEND: SYMBOL 0 ASBESTOS CONTAINING TAN CAULK AT STAIR STRINGER TO WALL JOINT TO BE REMOVED O STAIRWELL/CORRIDOR DOOR WITH ASBESTOS CONTAINING WINDOW GLAZING COMPOUND. ENTIRE DOOR/SIDE-LIGHT TO BE REMOVED 35 (1'�THIRD FLOOR ABATEMENT PLAN SCALE: 1/8" = 1'-0" NORTH Vfl A 379 0 E.lV UU N ALL GRUMMAN HALL 0 5'-4" 10'-8" 21'-4" SCALE: 3/32" = 1'-O" Cornell University Facilities Services 102 Humphreys Service Building Ithaca, NY 14853 No.1 Revision Project Name ' Date UPSON HALL RENOVATION CORNELL UNIVERSITY 124 HOY ROAD, ITHACA, NY 14850 ITHACA Seal NEW YORK ADELTA ENGINEERS, ARCHITECTS, & LAND SURVEYORS 860 Hooper Road Endwell, New York 13760 Tel: 607.231.6600 Fax: 607.231.6651 Email: mail@deltaengineers.com Web: www.deltaengineers.com Scale AS SHOWN Project No. 2015.030.059 UNAUTHORIZED ALTERATION OF THIS DRAWING IS A VIOLATION OF THE NEW YORK STATE EDUCATION LAW, SECTION 7209, SUBDIVISION 2. Date 03/24/2015 Drawing Title THIRD FLOOR ABATEMENT PLAN Drawing No. AR -0004