HomeMy WebLinkAbout_Conformed Set Volume 1 76DUFFS IH HALL CORRIDOR B 2000 GENERAL NOTES: 1. THE FOLLOWING ASBESTOS CONTAINING / ASBESTOS CONTAMINATED MATERIALS ARE NOT SHOWN BUT SHALL BE REMOVED AT ALL LOCATIONS WHERE PRESENT ON THE 2ND FLOOR: A. WALL MOUNTED BOARDS AND THEIR ASSOCIATED MASTIC/ADEHSIVE. REFERENCE DRAWING AR -0000 NOTE 7-F FOR ABATEMENT INFORMATION AND REQUIREMENTS. B. DOOR SLABS WITH ASSUMED ASBESTOS CONTAINING CORE MATERIAL. REFERENCE DRAWING AD -0120 FOR 2ND FLOOR DOORS TO BE REMOVED. REFERENCE DRAWING AR -0000 NOTE 7-G FOR ABATEMENT INFORMATION AND REQUIREMENTS. C. SINK BRACE MASTIC. REFERENCE DRAWING AR -0000 NOTE 7-J FOR ABATEMENT INFORMATION AND REQUIREMENTS. D. WINDOWS/ WINDOW SYSTEMS. REFERENCE DRAWING AR -0000 NOTE 7-P FOR ABATEMENT INFORMATION AND REQUIREMENTS. E. CURTAIN WALL SYSTEM. REFERENCE DRAWING AR -0000 NOTE 7-Q FOR ABATEMENT INFORMATION AND REQUIREMENTS. 2. ASBESTOS CONTAINING FLOOR TILE (VAT) SHOWN ON DRAWING AR -0003 REPRESENTS THE CONFIRMED LOCATIONS OF VAT AND MAY NOT REPRESENT ALL LOCATIONS WHERE VAT IS PRESENT ON THE 2ND FLOOR. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REMOVAL OF ALL 9" X 9" FLOOR TILE PRESENT ON THE 2ND FLOOR. REFERENCE DRAWING AR -0000 NOTE 7-A FOR ADDITIONAL VAT ABATEMENT INFORMATION AND REQUIREMENTS. 3. ASBESTOS CONTAINING PIPE AND PIPE FITTING INSULATION (TSI) SHOWN ON DRAWING AR -0003 REPRESENT THOSE 2ND FLOOR SPACES WHERE THE MATERIAL IS CONFIRMED TO BE PRESENT. TSI IS ALSO ASSUMED TO BE PRESENT IN CONCEALED WET -WALLS, PIPE CHASES, AND HARD CEILING PLENUM SPACES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REMOVAL OF ALL ASBESTOS CONTAINING PIPE AND PIPE FITTING INSULATION PRESENT ON THE 2ND FLOOR. REFERENCE MECHANICAL DEMOLITION DRAWINGS MD -2002A / MD2002B AND PLUMBING DEMOLITION DRAWING PD -2002 FOR EXISTING 2ND FLOOR PIPING LOCATIONS. REFERENCE DRAWING AR -0000 NOTE 7-B FOR ADDITIONAL TSI ABATEMENT INFORMATION AND REQUIREMENTS. 265 LEGEND AND KEYED NOTES SYMBOL MATERIAL/ITEM TO BE REMOVED STAIRWELL/CORRIDOR DOOR WITH ASBESTOS CONTAINING WINDOW GLAZING COMPOUND. ENTIRE DOOR/SIDE-LIGHT TO BE REMOVED SPACE / ROOM / AREA WITH CONFIRMED ASBESTOS CONTAINING PIPE / PIPE FITTING INSULATION TO BE REMOVED V////1 - LOCATION OF CONFIRMED ASBESTOS CONTAINING FLOOR TILE TO BE REMOVED NOT IN CONTRACT KEYED NOTES LEGEND: SYMBOL O STAIRWELL/CORRIDOR DOOR WITH ASBESTOS CONTAINING WINDOW GLAZING COMPOUND. ENTIRE DOOR/SIDE-LIGHT TO BE REMOVED SECOND FLOOR ABATEMENT PLAN SCALE: 3/32" =1'-0" NORTH =SON HALL AN HALL 0 5'-4" 10'-8" 21'-4" SCALE: 3/32" = 1'-O" Cornell University Facilities Services 102 Humphreys Service Building Ithaca, NY 14853 No.1 Revision Project Name ' Date UPSON HALL RENOVATION CORNELL UNIVERSITY 124 HOY ROAD, ITHACA, NY 14850 ITHACA Seal NEW YORK ADELTA ENGINEERS, ARCHITECTS, & LAND SURVEYORS 860 Hooper Road Endwell, New York 13760 Tel: 607.231.6600 Fax: 607.231.6651 Email: mail@deltaengineers.com Web: www.deltaengineers.com Scale AS SHOWN Project No. 2015.030.059 UNAUTHORIZED ALTERATION OF THIS DRAWING IS A VIOLATION OF THE NEW YORK STATE EDUCATION LAW, SECTION 7209, SUBDIVISION 2. Date 03/24/2015 Drawing Title SECOND FLOOR ABATEMENT PLAN Drawing No. AR -0003