HomeMy WebLinkAbout_Conformed Set Volume 1 75DL FF
ELD
A L. L
UPSON VA
000
Dal
"PP
GENERAL NOTES:
1. THE FOLLOWING ASBESTOS CONTAINING / ASBESTOS CONTAMINATED MATERIALS ARE NOT SHOWN BUT SHALL BE REMOVED AT
ALL LOCATIONS WHERE PRESENT ON THE 1ST FLOOR:
A. WALL MOUNTED BOARDS AND THEIR ASSOCIATED MASTIC/ADEHSIVE. REFERENCE DRAWING AR -0000 NOTE 7-F FOR
ABATEMENT INFORMATION AND REQUIREMENTS.
B. DOOR SLABS WITH ASSUMED ASBESTOS CONTAINING CORE MATERIAL. REFERENCE DRAWING AD -0110 FOR 1ST FLOOR DOORS
TO BE REMOVED. REFERENCE DRAWING AR -0000 NOTE 7-G FOR ABATEMENT INFORMATION AND REQUIREMENTS.
C. SINK BRACE MASTIC. REFERENCE DRAWING AR -0000 NOTE 7-J FOR ABATEMENT INFORMATION AND REQUIREMENTS.
D. INTERIOR VENT CAULK. REFERENCE DRAWING AR -0000 NOTE 7-L FOR ABATEMENT INFORMATION AND REQUIREMENTS.
E. WINDOWS / WINDOW SYSTEMS. REFERENCE DRAWING AR -0000 NOTE 7-P FOR ABATEMENT INFORMATION AND REQUIREMENTS.
F. CURTAIN WALL SYSTEM. REFERENCE DRAWING AR -0000 NOTE 7-Q FOR ABATEMENT INFORMATION AND REQUIREMENTS.
2. ASBESTOS CONTAINING FLOOR TILE (VAT) SHOWN ON DRAWING AR -0002 REPRESENTS THE CONFIRMED LOCATIONS OF VAT AND
MAY NOT REPRESENT ALL LOCATIONS WHERE VAT IS PRESENT ON THE 1ST FLOOR. THE CONTRACTOR SHALL BE RESPONSIBLE
FOR THE REMOVAL OF ALL 9" X 9" FLOOR TILE PRESENT ON THE 1ST FLOOR. REFERENCE DRAWING AR -0000 NOTE 7-A FOR
ADDITIONAL VAT ABATEMENT INFORMATION AND REQUIREMENTS.
3. ASBESTOS CONTAINING PIPE AND PIPE FITTING INSULATION (TSI) SHOWN ON DRAWING AR -0002 REPRESENT THOSE 1ST FLOOR
SPACES WHERE THE MATERIAL IS CONFIRMED TO BE PRESENT. TSI IS ALSO ASSUMED TO BE PRESENT IN CONCEALED
WET -WALLS, PIPE CHASES, AND HARD CEILING PLENUM SPACES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REMOVAL
OF ALL ASBESTOS CONTAINING PIPE AND PIPE FITTING INSULATION PRESENT ON THE 1ST FLOOR. REFERENCE MECHANICAL
DEMOLITION DRAWINGS MD -2001A/ MD2001B AND PLUMBING DEMOLITION DRAWING PD -2001 FOR EXISTING 1ST FLOOR PIPING
LOCATIONS. REFERENCE DRAWING AR -0000 NOTE 7-B FOR ADDITIONAL TSI ABATEMENT INFORMATION AND REQUIREMENTS.
LEGEND AND KEYED NOTES
SYMBOL
MATERIAL/ITEM TO BE REMOVED
Vj///1
SPACE / ROOM / AREA WITH CONFIRMED ASBESTOS CONTAINING PIPE / PIPE FITTING INSULATION TO BE REMOVED
-
LOCATION OF CONFIRMED ASBESTOS CONTAINING FLOOR TILE TO BE REMOVED
O
ASBESTOS CONTAINING GRAY BASE -COAT PLASTER TO BE REMOVED
��A;��� I
NOT IN CONTRACT
KEYED NOTES LEGEND:
SYMBOL
0
ASBESTOS CONTAINING GRAY INTERIOR DOOR FRAME CAULK TO BE REMOVED
03
ASBESTOS CONTAINING EXTERIOR DOOR FRAME CAULK TO BE REMOVED
O
STAIRWELL/CORRIDOR DOOR WITH ASBESTOS CONTAINING WINDOW GLAZING COMPOUND. ENTIRE DOOR/SIDE-LIGHT
TO BE REMOVED
OPEN 10
BELOW
Pr
FIRST FLOOR ABATEMENT PLAN
SCALE: 1/8" =1'-0"
NORTH
0 5'-4" 10'-8" 21'-4"
SCALE: 3/32" = 1'-O"
Cornell University
Facilities Services
102 Humphreys Service Building
Ithaca, NY 14853
No. 1 Revision ' Date
Project Name
UPSON HALL RENOVATION
CORNELL UNIVERSITY
124 HOY ROAD, ITHACA, NY 14850
ITHACA NEW YORK
ADELTA
ENGINEERS, ARCHITECTS, & LAND SURVEYORS
860 Hooper Road
Endwell, New York 13760
Tel: 607.231.6600
Fax: 607.231.6651
Email: mail@deltaengineers.com
Web: www.deltaengineers.com
Seal
Scale
AS SHOWN
Project No.
2015.030.059
UNAUTHORIZED ALTERATION OF THIS
DRAWING IS A VIOLATION OF THE
NEW YORK STATE EDUCATION LAW,
SECTION 7209, SUBDIVISION 2.
Date
03/24/2015
Drawing Title
FIRST FLOOR
ABATEMENT PLAN
Drawing No.
AR -0002