HomeMy WebLinkAbout_Conformed Set Volume 1 74GENERAL NOTES:
1. THE FOLLOWING ASBESTOS CONTAINING / ASBESTOS CONTAMINATED MATERIALS ARE NOT SHOWN BUT SHALL BE REMOVED AT
ALL LOCATIONS WHERE PRESENT ON THE BASEMENT LEVEL:
A. WALL MOUNTED BOARDS AND THEIR ASSOCIATED MASTIC/ADEHSIVE. REFERENCE DRAWING AR -0000 NOTE 7-F FOR
ABATEMENT INFORMATION AND REQUIREMENTS.
B. DOOR SLABS WITH ASSUMED ASBESTOS CONTAINING CORE MATERIAL. REFERENCE DRAWING AD -0100 FOR BASEMENT LEVEL
DOORS TO BE REMOVED. REFERENCE DRAWING AR -0000 NOTE 7-G FOR ABATEMENT INFORMATION AND REQUIREMENTS.
C. SINK BRACE MASTIC. REFERENCE DRAWING AR -0000 NOTE 7-J FOR ABATEMENT INFORMATION AND REQUIREMENTS.
D. UNDERGROUND CHILLED WATER SUPPLY AND RETURN PIPING, REFERENCE DRAWING C-1101 FOR CHILLED WATER PIPING
LOCATIONS. REFERENCE DRAWING AR -0000 NOTE 7-C FOR ABATEMENT INFORMATION AND REQUIREMENTS.
D. UNDERGROUND STORM TRANSITE PIPING, REFERENCE DRAWINGS C-1101 AND C31010 FOR STORM PIPING LOCATIONS.
REFERENCE DRAWING AR -0000 NOTE 7-D FOR ABATEMENT INFORMATION AND REQUIREMENTS.
E. WINDOWS / WINDOW SYSTEMS. REFERENCE DRAWING AR -0000 NOTE 7-P FOR ABATEMENT INFORMATION AND
REQUIREMENTS.
F. CURTAIN WALL SYSTEM. REFERENCE DRAWING AR -0000 NOTE 7-Q FOR ABATEMENT INFORMATION AND REQUIREMENTS.
2. ASBESTOS CONTAINING FLOOR TILE (VAT) SHOWN ON DRAWING AR -0001 REPRESENTS THE CONFIRMED LOCATIONS OF VAT AND
MAY NOT REPRESENT ALL LOCATIONS WHERE VAT IS PRESENT ON THE BASEMENT LEVEL. THE CONTRACTOR SHALL BE
RESPONSIBLE FOR THE REMOVAL OF ALL 9" X 9" FLOOR TILE PRESENT ON THE BASEMENT LEVEL. REFERENCE DRAWING AR -0000
NOTE 7-A FOR ADDITIONAL VAT ABATEMENT INFORMATION AND REQUIREMENTS.
3. ASBESTOS CONTAINING PIPE AND PIPE FITTING INSULATION (TSI) SHOWN ON DRAWING AR -0001 REPRESENT THOSE BASEMENT
SPACES WHERE THE MATERIAL IS CONFIRMED TO BE PRESENT. TSI IS ALSO ASSUMED TO BE PRESENT IN CONCEALED
WET -WALLS, PIPE CHASES, AND HARD CEILING PLENUM SPACES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REMOVAL
OF ALL ASBESTOS CONTAINING PIPE AND PIPE FITTING INSULATION PRESENT ON THE BASEMENT LEVEL. REFERENCE
MECHANICAL DEMOLITION DRAWINGS MD -2000A / MD2000B AND PLUMBING DEMOLITION DRAWING PD -2000 FOR EXISTING
BASEMENT LEVEL PIPING LOCATIONS. REFERENCE DRAWING AR -0000 NOTE 7-B FOR ADDITIONAL TSI ABATEMENT INFORMATION
AND REQUIREMENTS.
.................................
LEGEND AND KEYED NOTES
SYMBOL
MATERIAL/ITEM TO BE REMOVED
V//f/1
SPACE / ROOM / AREA WITH CONFIRMED ASBESTOS CONTAINING PIPE / PIPE FITTING INSULATION TO BE REMOVED
-
LOCATION OF CONFIRMED ASBESTOS CONTAINING FLOOR TILE TO BE REMOVED
NOT IN CONTRACT
KEYED NOTES LEGEND:
SYMBOL
OASBESTOS
CONTAINING EXTERIOR DOOR FRAME CAULK TO BE REMOVED
O
STAIRWELL/CORRIDOR DOOR WITH ASBESTOS CONTAINING WINDOW GLAZING COMPOUND. ENTIRE DOOR/SIDE-LIGHT
TO BE REMOVED
BASEMENT ABATEMENT PLAN
SCALE: 1/8" = 1'-0"
NORTH
0 5'-4" 10'-8"
21'-4"
SCALE: 3/32" = 1'-O"
Cornell University
Facilities Services
102 Humphreys Service Building
Ithaca, NY 14853
No. 1 Revision
Project Name
' Date
UPSON HALL RENOVATION
CORNELL UNIVERSITY
124 HOY ROAD, ITHACA, NY 14850
ITHACA
Seal
NEW YORK
ADELTA
ENGINEERS, ARCHITECTS, & LAND SURVEYORS
860 Hooper Road
Endwell, New York 13760
Tel: 607.231.6600
Fax: 607.231.6651
Email: mail@deltaengineers.com
Web: www.deltaengineers.com
Scale
AS SHOWN
Project No.
2015.030.059
UNAUTHORIZED ALTERATION OF THIS
DRAWING IS A VIOLATION OF THE
NEW YORK STATE EDUCATION LAW,
SECTION 7209, SUBDIVISION 2.
Date
03/24/2015
Drawing Title
BASEMENT ABATEMENT
PLAN
Drawing No.
AR -0001