_Conformed Set Volume 1 5
CONTROL AREA B-00CONTROL AREA A-001HR SEPARATIONCONTROL AREA C-00CONTROL AREA B-01CONTROL AREA A-001HR SEPARATIONCONTROL AREA C-01NO CHEMICAL USE IN OFFICE AREAEXISTING 4 STORY ATRIUM.NO CHEMICAL USE1HR SEPARATION3HR SEPARATIONCONTROL AREA B-02CONTROL AREA A-011HR SEPARATIONEXISTING 4 STORY ATRIUM.NO CHEMICAL USENO CHEMICAL USE INCIT LAB3HR SEPARATION1 HOURSEPARATIONCONTROL AREA B-03CONTROL AREA A-012HR SEPARATIONEXISTING 4 STORY ATRIUM.NO CHEMICAL USE3HR SEPARATIONCONTROL AREA B-04CONTROL AREA A-012HR SEPARATIONEXISTING 4 STORY ATRIUM.NO CHEMICAL USE3HR SEPARATIONCONTROL AREA B-05CONTROL AREA A-012HR SEPARATION3HR SEPARATIONEXISTING 4 STORY ATRIUM.NO CHEMICAL USETABLE 414.2.2 DESIGN AND NUMBER OF CONTROL AREASFLOOR LEVELABOVEGRADEPLANEPERCENTAGE OF THE MAXIMUMALLOWABLE QUANTITY PERCONTROL AREANUMBER OF CONTROL AREASPER FLOORFIRE-RESISTANCE RATING FORFIRE BARRIERS IN HOURSBELOWGRADEPLANE65432112.512.512.5507510075122223432221111NOTE: PERCENTAGES SHALL BE OF THE MAXIMUM ALLOWABLE QUANTITY PER CONTROL AREA SHOWN IN TABLES 307.1(1)AND 307.1(2), WITH ALL INCREASES ALLOWED IN THE NOTES TO THOSE TABLES.For SI: 1 cubic foot = 0.023 m3, 1 pound = 0.454 kg, 1 gallon = 3.785 L.NL = Not Limited; N/A = Not Applicable; UD = Unclassified Detonablea. For use of control areas, see Section 414.2.b. The aggregate quantity in use and storage shall not exceed the quantity listed for storage.c. The quantities of alcoholic beverages in retail and wholesale sales occupancies shall not be limited providing the liquids are packaged in individual containers not exceeding 1.3 gallons.In retail and wholesale sales occupancies, the quantities of medicines, foodstuffs, consumer or industrial products, and cosmetics containing not more than 50 percent by volume of water-miscible liquids with the remainder of the solutions not being flammable, shall not be limited, provided that such materials are packaged in individual containers not exceeding 1.3 gallons.d. Maximum allowable quantities shall be increased 100 percent in buildings equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1.WhereNote ealso applies, the increase for both notes shall be applied accumulatively.e. Maximum allowable quantities shall be increased 100 percent when stored in approved storage cabinets, day boxes, gas cabinets, exhausted enclosures or safety cans. Where Note dalso applies, the increase for both notes shall be applied accumulatively.f. The permitted quantities shall not be limited in a building equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1.g. Permitted only in buildings equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1.h. Containing not more than the maximum allowable quantity per control area of Class IA, IB or IC flammable liquids.i. Inside a building, the maximum capacity of a combustible liquid storage system that is connected to a fuel-oil piping system shall be 660 gallons provided such system complies with theFire Code of New York State.j. Quantities in parenthesis indicate quantity units in parenthesis at the head of each column.k. A maximum quantity of 200 pounds of solid or 20 gallons of liquid Class 3 oxidizers is allowed when such materials are necessary for maintenance purposes, operation or sanitation ofequipment. Storage containers and the manner of storage shall be approved.l. Net weight of the pyrotechnic composition of the fireworks. Where the net weight of the pyrotechnic composition of the fireworks is not known, 25 percent of the gross weight of thefireworks, including packaging, shall be used.m. For gallons of liquids, divide the amount in pounds by 10 in accordance with Section 2703.1.2 of the Fire Code of New York State.n. For storage and display quantities in Group M and storage quantities in Group S occupancies complying with Section 414.2.5, see Tables 414.2.5(1) and 414.2.5(2).o. Densely packed baled cotton that complies with the packing requirements of ISO 8115 shall not be included in this material class.p. The following shall not be included in determining the maximum allowable quantities:1. Liquid or gaseous fuel in fuel tanks on vehicles.2. Liquid or gaseous fuel in fuel tanks on motorized equipment operated in accordance with this code.3. Gaseous fuels in piping systems and fixed appliances regulated by the Fuel Gas Code of New York State.4. Liquid fuels in piping systems and fixed appliances regulated by the Mechanical Code of New York State.01/2"1"2"SheetTitleApprovedCheckedDrawnJob NumberDateSheet InformationRevisionsMEP FPME Engineers29 West 38th Street, 5th FloorNew York, NY 10018t 212.447.6770f 212.447.6615STRUCTURAL ENGINEER/SUSTAINABILITY CONSULTANTThornton Tomasetti51 Madison Ave.New York, N.Y. 10010t 917.661.7800f 917.661.7801LIGHTING CONSULTANTLumen Architecture214 W 29th Street Suite 1005New York, NY 10001t 212.564.6469f 917.591.2524LANDSCAPE ARCHITECTTrowbridge Wolf Michaels1001 West Seneca Street Suite 101Ithaca, NY 14850t 607.277.1400f 000.000.0000162345AEBCD162345AEBCDCopyright © 2013 Perkins+Will227 West 29th Street, 7th Flr.New York, NY 10001t: 212 505-5955f: 212 505-1648CIVIL ENGINEERTG Miller PC203 North Aurora StreetIthaca, NY 14850t 607.272.6477f 607.273.6322AV / ACOUSTICSThe Sextant Group244 Madison Avenue Suite 311New York NY 10016t 877.684.2311f 412.323.8538CODE CONSULTANTCode Consultants ProfessionalEngineers, PC215 West 40th Street 15th FloorNew York, NY 10018t 212.216.9596f 212.216.96193/31/2015 4:21:35 PMc:\temp\Upson Hall _ ARCH_sobeskic.rvtLS-0003CONTROL AREAPLANSCASAHS031549.00002/27/2015RWGUpson HallRenovation124 Hoy Rd, Ithaca, NY 14850CornellUniversity215 Park Avenue South4th FloorNew York, NY 10003t 212.251.7000f 212.251.7111www.perkinswill.com 1" = 30'-0"A2LEVEL 00 CONTROL AREA PLAN 1" = 30'-0"A4LEVEL 01 CONTROL AREA PLAN 1" = 30'-0"B2LEVEL 02 CONTROL AREA PLAN 1" = 30'-0"B4LEVEL 03 CONTROL AREA PLAN 1" = 30'-0"D2LEVEL 04 CONTROL AREA PLAN 1" = 30'-0"D4LEVEL 05 CONTROL AREA PLANLEVEL ABOVE GRADE = 1LEVEL ABOVE GRADE = 2LEVEL ABOVE GRADE = 3LEVEL ABOVE GRADE = 4LEVEL ABOVE GRADE = 5LEVEL ABOVE GRADE = 6NO ISSUE DATE3 BID SET 15/02/274 ADDENDUM NO 3 15/03/31