HomeMy WebLinkAbout_Conformed Set Volume 1 45FFE 802.10FFE 789.00FFE 802.00EE +/-788.98(14" BELOW THRESHOLD)MATCH EXISTING WALL HEIGHT+/- TW 801.10+/- BW 789.80CONTRACT LIMIT LINECONTRACT LIMIT LINECONTRACT LIMIT LINECONTRACT LIMIT LINECONTRACT LIMIT LINE
MATCH EXISTING WALL HEIGHT+/- TW 801.10+/- BW 789.801.2%EL 788.98EL 788.92EL 788.581.2%EL 788.25MATCH EXISTING+/- EL 789.03AREA DRAINRIM 788.48(SEE CIVILAREA DRAINRIM 788.15(SEE CIVIL)EL 788.25DRAINAGE INLETRIM 792.50(SEE CIVIL)EL 788.58TW 792.95BW 792.70TW 792.95BW 792.70TW 792.95BW 792.70TIE INTO EXISTING WALLTW +/- 792.95BW 789.0379
7
79
6
7
9
5
79
4
79
3 EXISTINGTW +/- 797.47BW 793.50790EL 801.98EL 801.98EL +/-801.78EL +/-802.08EL +/-801.98(14" BELOW THRESHOLD)BS 783.68TS 788.688.33%
MAX.TR 788.78BR 786.28TW 789.50BW 786.402.0%TW 786.61BW 786.28TW 789.11BW 788.82TW 789.01BW 788.68TW 784.10BW 783.68TW 789.18BW 787.68TW 789.18BW 786.68TW 789.18BW 785.68TW 789.18BW 784.6810 STARIS @ 6"TW 789.18BW 783.68TRENCH DRAINRIM 786.28UPSONHALLPHILLIPSHALLUPSONHALL4.4%1.0%AREA DRAINRIM 801.85SEE CIVIL)2.0%2.0%EL 783.571.0%2.0%8.33%MAX.EE +/-788.98(14" BELOW THRESHOLD)EL 783.62EL 783.62EL 783.62TW 789.11BW 788.78780EE +/-808.98(14" BELOW THRESHOLD)EL 788.98STRIPE PARKING SPACES AND REINSTALLDESIGNATED CAMPUS PARKING SIGNS785784TO BE ADJUSTED TO MEET PROPOSED GRADES(SEE CIVIL)EL 788.94EL 788.731.7%EL 783.57EL 783.64TW 789.50BW 787.06MATCH EXISTINGEL +/-783.10TW 786.18BW 783.15EL 788.98792791790TW +/-801.10BW +/-792.81TW 792.95BW 792.70DRAINAGE INLETRIM 788.25 (SEE CIVIL)DRAINAGE INLETRIM 783.56(SEE CIVIL)MATCHEXISTINGEL 779.60MATCHEXISTINGEL 779.502.0%TR 786.28TW 786.61BW 786.40TW 786.61BW 786.285.00%
MAX.EL 783.68EL 783.57BR 783.78TW 784.11BW 783.78UPSONHALLDRAINAGE INLETRIM 792.40(SEE CIVIL)799800798797796795801794793TW 784.68BW 783.68TW 785.68BW 784.68TW 786.68BW 785.68TW 787.68BW 786.68GENERAL SHEET NOTES - GRADING1.GENERAL CONTRACTOR SHALL NOTIFY ALL UTILITY COMPANIES HAVING UNDERGROUNDUTILITIES ON SITE OR IN RIGHT-OF-WAY PRIOR TO EXCAVATION. CONTRACTOR SHALLCONTACT UTILITY LOCATING COMPANY AND LOCATE ALL UTILITIES PRIOR TO GRADINGSTART.2.GRADING AROUND EXISTING TREES TO BE MINIMIZED.3.MINIMIZE IMPACT TO EXISTING, REMAINING LANDSCAPE WHILE EXCAVATING. GREAT CAREIS TO BE TAKEN TO AVOID DISTURBING ROOTS OF EXISTING TREES. HAND EXCAVATIONAND/OR EXCAVATION WITH AN AIR SPADE WILL BE REQUIRED WHERE EXISTING TREEROOTS ARE PRESENT.4.ALL EXISTING UTILITY COVERS AND GRATES WITHIN THE AREA OF DISTURBANCE ARE TO BEADJUSTED TO MEET GRADES.5.SEE CIVIL, ELECTRICAL AND PLUMBING DRAWINGS FOR UTILITIES.6.THE CONTRACTOR SHALL FIELD VERIFY EXISTING TOPOGRAPHY PRIOR TOCOMMENCEMENT OF EARTHWORK OPERATIONS. ANY DISCREPANCIES WHICH WILL AFFECTTHE WORK REQUIRED AS PART OF THE CONTRACT DOCUMENTS SHALL BE IMMEDIATELYREPORTED TO THE LANDSCAPE ARCHITECT.7.ENTRANCE ELEVATION (EE) BASED ON SURVEY. ELEVATION IMMEDIATELY OUTDIE DOORTHRESHOLD NOT TO EXCEED 1/4". CONTRACTOR TO VERIFY.EXISTING CONTOURMAJOR CONTOURSPOT ELEVATIONEXISTING SPOT ELEVATIONBW BOTTOM OF WALLTW TOP OF WALLCONTOURBC BOTTOM OF CURBTC TOP OF CURBEL SPOT ELEVATIONDRAINAGE INLET (SEE CIVIL)TRENCH DRAIN (SEE CIVIL)TR TOP OF RAMPBR BOTTOM OF RAMPEL 802.07RIM RIM ELEVATIONEE ENTRANCE ELEVATION (OUTSIDE BUILDING)LEGENDVALVE (SEE CIVIL)CONTRACT LIMIT LINEMANHOLE (SEE CIVIL)SheetTitleApprovedCheckedDrawnJob NumberDateSheet InformationRevisionsMEP FPME Engineers29 West 38th Street, 5th FloorNew York, NY 10018t 212.447.6770f 212.447.6615STRUCTURAL ENGINEER/SUSTAINABILITY CONSULTANTThornton Tomasetti51 Madison Ave.New York, N.Y. 10010t 917.661.7800f 917.661.7801LIGHTING CONSULTANTLumen Architecture214 W 29th Street Suite 1005New York, NY 10001t 212.564.6469f 917.591.2524LANDSCAPE ARCHITECT1001 West Seneca Street Suite 101Ithaca, NY 14850t 607.277.1400f 000.000.0000162345AEBCD162345AEBCD&RS\ULJKW3HUNLQV:LOO227 West 29th Street, 7th Flr.New York, NY 10001t: 212 505-5955f: 212 505-1648CIVIL ENGINEERTG Miller PC203 North Aurora StreetIthaca, NY 14850t 607.272.6477f 607.273.6322AV / ACOUSTICSThe Sextant Group244 Madison Avenue Suite 311New York NY 10016t 877.684.2311f 412.323.8538CODE CONSULTANTCode Consultants ProfessionalEngineers, PC215 West 40th Street 15th FloorNew York, NY 10018t 212.216.9596f 212.216.96195/30/2014 5:03:24 PMc:\temp\Cornell-Upson Hall_sobeskic.rvt
031549.000Upson HallRenovation124 Hoy Rd, Ithaca, NY 14850CornellUniversity215 Park Avenue South4th FloorNew York, NY 10003t 212.251.7000f 212.251.7111www.perkinswill.comNOISSUEDATE08/29/20141100% DD DOCUMENTS14/08/28214/11/0750% CONSTRUCTIONDOCUMENTS315/02/27BID SET415/03/31ADDENDUM NO 3PHASE 1 & 2GRADING PLANKAMKAMJLFMATCH LINE
MATCH LINE
L-1302
L-1301
L-1302
L-1301
MATCH LINE
MATCH LINEKEYMAP