Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
_Conformed Set Volume 1 408
6 20 19 18 17 16 15 14 13 12 11 10 9 2.6 8 6.1 3 2 1 T S R R.3 Q.1 O A B C D E F G H J K L M N P Q 8.18.910.1 CA CA W18X35L4X4X1/2W18X35W18X35L4X4X1/2L4X4X1/2 L4X4X1/2W18X35W18X35 W18X35NEW 24"x24" GRADE BEAMSL4X4X1/2 W14X22 W14X22 W14X22 L4X4X1/2W14X22W14X22W14X22W14X22 W14X22NEW 24"x24" GRADE BEAMS1 S-0300 16' - 0" 16' - 0" 16' - 0" 16' - 0" 16' - 0" 16' - 0" 16' - 0" 16' - 0" 16' - 0" 16' - 0" 12' - 0" 20' - 0" 22' - 0" 26' - 0" 22' - 0" 12' - 0"16' - 0"16' - 0"16' - 0"16' - 0"16' - 0"16' - 0"16' - 0"16' - 0"16' - 0"16' - 0"16' - 0"16' - 0"16' - 0"16' - 0"20' - 0"12' - 0"12' - 0"24' - 11" 16' - 0" 16' - 0"27' - 0" 21' - 0" REMOVE EXISTING CONCRETE WALL COLUMN TO REMAIN ASSUME ADDITIONAL FINISH WORK AT SIDES OF COLUMNS & WALLS W10X19W10X19W10X19W10X191 S-0301 NEW 6" SLAB ON GRADE WITH WWF REINFORCING 2 S-0301 V55V55V55V55V55V55V55V55V55V55V55V55V35 V35 V35 V35 V35 V35 V35 V35 V35 V35 V35 V35 ADD 6" OF LIGHTWEIGHT CONCRETE FILL TO RAISE PIT DEPTH. REINFORCE WITH WWM 6X6XW2.9XW2.9 W14X22 L3X3X3/8 . SITE WALL. SEE 4/S-0301 FOR FOOTING DETAIL. L7X4X1/2 L4X4X3/8L4X4X3/8 L4X4X3/8L7X4X1/2L4X4X3/8NEW 2'x2' SUMP PIT 2' DEEP FROM NEW TOP OF PIT SLAB V15 V15 V15 V15 SEE NOTE 8 TYPICAL PERIMETER ANGLES SEE NOTE 8 TYPICAL PERIMETER ANGLES SEE NOTE 8 TYPICAL PERIMETER ANGLES 5 S-0301 CMU INFILL OF EXISTING OPENING TO MATCH EXISTING CMU SEE A-3004 FOR LOCATION NEW FACADE ANCHORED TO EXISTING CMU. GPR CMU TO VERIFY EXISTING REINFORCING. INDICATES EXISTING MEMBER INDICATES NEW MEMBER INDICATES EXISTING MEMBER TO BE DEMOLISHED INDICATES COLUMN ABOVE INDICATES NEW SLAB OPENING NOTES: INDICATES 4 1/2" NW CONCRETE OVER 2" COMPOSITE STEEL DECK AND SLAB DIRECTION C.A. N.S.O. 1. 2. 3. 4. 5. 6. 7. 8. SEE A-4200 SERIES FOR FACADE CONNECTION DETAILS. ANGLE ANCHORS TO EXISTING CONCRETE SHOULD BE DESIGNED FOR THE FOLLOWING FACTORED LOADS: 0.6K VERTICAL AND 1K HORIZONTAL REACTIONS PER LINEAR FOOT (FACTORED), APPLIED AT C.G. OF HORIZONTAL LEG OF ANGLE. 9. AT ALL STEEL FRAMING SUPPORTING COMPOSITE DECK ASSUME A MINIMUM OF ONE 4"x5/8" NELSON STUD PER FOOT.01/2"1"2"Sheet Title Approved Checked Drawn Job Number Date Sheet Information Revisions MEP FP ME Engineers 29 West 38th Street, 5th Floor New York, NY 10018 t 212.447.6770 f 212.447.6615 STRUCTURAL ENGINEER/ SUSTAINABILITY CONSULTANT Thornton Tomasetti 51 Madison Ave. New York, N.Y. 10010 t 917.661.7800 f 917.661.7801 LIGHTING CONSULTANT Lumen Architecture 214 W 29th Street Suite 1005 New York, NY 10001 t 212.564.6469 f 917.591.2524 LANDSCAPE ARCHITECT Trowbridge Wolf Michaels 1001 West Seneca Street Suite 101 Ithaca, NY 14850 t 607.277.1400 f 000.000.0000 162345 A E B C D 162345 A E B C D Copyright © 2013 Perkins+Will 227 West 29th Street, 7th Flr. New York, NY 10001 t: 212 505-5955 f: 212 505-1648 CIVIL ENGINEER TG Miller PC 203 North Aurora Street Ithaca, NY 14850 t 607.272.6477 f 607.273.6322 AV / ACOUSTICS The Sextant Group 244 Madison Avenue Suite 311 New York NY 10016 t 877.684.2311 f 412.323.8538 CODE CONSULTANT Code Consultants Professional Engineers, PC 215 West 40th Street 15th Floor New York, NY 10018 t 212.216.9596 f 212.216.9619 04/06/2015 031549.000 PK RO 1 100% DD DOCUMENTS 14/08/28 2 50% CONSTRUCTION DOCUMENTS 14/11/07 3 90% CONSTRUCTION DOCUMENTS 15/01/26 4 BID SET 15/02/27 5 ADDENDUM 2 15/03/20 NO ISSUE DATE 6 ADDENDUM 5 15/04/08 4/8/2015 8:50:03 AMC:\Scratch\Cornell_UpsonHall_R2015_pkenny.rvtS-0100 BASEMENT LEVEL PLAN Upson Hall 410 THURSTON AVE., ITHACA, NY CORNELL UNIVERSITY 3/32" = 1'-0" BASEMENT LEVEL PLAN1 215 Park Avenue South 4th Floor New York, NY 10003 t 212.251.7000 f 212.251.7111 www.perkinswill.com TOS EL. -13'-0"