Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
_Conformed Set Volume 1 376
PLANMETAL "C-H" STUD(1) LAYER 5/8" FIRE RATEDGYP BD EA FACECONT SEALANTCUT STUDS 1/2" SHORT OFTOP RUNNER TO ALLOW FORDEFLECTION, DO NOT FASTENGYP BD TO RUNNERBASE/HEADPARTITIONTAGSTUDSIZESTUDGAUGESTUDSPACINGMAX HT (5 PSF)L/240 L/360MAX HT (10 PSF)L/240 L/360FIRE RATING/TEST NOACOUSTIC PROPERTIES WALLTHKSTC INSUL THK TEST NOCONT SEALANT OFFASTENER2" MIN1/2"23L 2-1/2" CH 25 GA 24" OC 11'-5" 10'-0" 9'-1" 7'-11" 2 HR/UL DES U438 47 1" USG-750706 3-3/4"1" SHAFT WALL LINERMTL "J" RUNNERMTL "J" RUNNER 23M 4" CH 25 GA 24" OC 14'-8" 12'-10" 11'-8" 10'-2" 2 HR/UL DES U438 47 1" USG-750706 5-1/4" 23N 2-1/2" CH 20 GA 24" OC 13'-6" 11'-9" 10'-9" 9'-4" 2 HR/UL DES U438 47 1" USG-750706 3-3/4"23P 4" CH 20 GA 24" OC 18'-9" 16'-5" 14'-11" 13'-0" 2 HR/UL DES U438 47 1" USG-750706 5-1/4"23Q 6" CH 20 GA 24" OC 26'-4" 23'-0" 20'-5" 18'-3" 2 HR/UL DES U438 47 1" USG-750706 7-1/4"SOUND ATTENUATIONBLANKETLINE OF STRUCTUREPLANMETAL STUD(2) LAYERS 5/8" FIRE RATEDGYP BD EACH FACECONT ACOUSTICAL SEALANTCUT STUDS 1/2" SHORT OFTOP RUNNER TO ALLOW FORDEFLECTION, DO NOT FASTENGYP BD TO RUNNERBASE/HEADPARTITIONTAGSTUDSIZESTUDGAUGESTUDSPACINGMAX HT (5 PSF)L/240 L/360MAX HT (10 PSF)L/240 L/360FIRE RATING/TEST NOACOUSTIC PROPERTIES WALLTHKSTC INSUL THK TEST NOCONT ACOUSTICAL SEALANT OFFASTENER2" MIN1/2"24B 1-5/8" 25 GA 24" 7'-6" 6'-7" -- -- 2HR/UL DES U420 52 3 1/2" SEE NOTE VARIESNOTE: STC 52 BASED UPON TEST RAL-TL-76-1625/8" (12" WIDTH) GYP BDCROSS BRACING 4'-0" OCVERTICAL SPACING MAX24C 2-1/2" 25 GA 24" 10'-7" 9'-2" -- -- 2HR/UL DES U420 52 3 1/2" SEE NOTE VARIESSOUND ATTENUATION BLANKETLINE OF STRUCTURE24G 2-1/2" 20 GA 24" 11'-11" 10'-5" -- -- 2HR/UL DES U420 52 3 1/2" SEE NOTE VARIESPLANMETAL STUD(1) LAYERS 5/8" FIRE RATEDGYP BD EACH FACECONT ACOUSTICAL SEALANTCUT STUDS 1/2" SHORT OFTOP RUNNER TO ALLOW FORDEFLECTION, DO NOT FASTENGYP BD TO RUNNERBASE/HEADPARTITIONTAGSTUDSIZESTUDGAUGESTUDSPACINGMAX HT (5 PSF)L/240 L/360MAX HT (10 PSF)L/240 L/360FIRE RATING/TEST NOACOUSTIC PROPERTIES WALLTHKSTC INSUL THK TEST NOCONT ACOUSTICAL SEALANT OFFASTENER2" MIN1/2"25A 6" & 2-1/2" 25 GA 24" 7'-6" 6'-7" -- -- 2HR/UL DES U420 52 3 1/2" SEE NOTE 9-3/4"NOTE: STC 52 BASED UPON TEST RAL-TL-76-1625/8" (12" WIDTH) GYP BDCROSS BRACING 4'-0" OCVERTICAL SPACING MAXSOUND ATTENUATION BLANKETLINE OF STRUCTUREPLANMETAL STUD(2) LAYERS 5/8" FIRE RATEDGYP BD EACH FACECONT ACOUSTICAL SEALANTCUT STUDS 1/2" SHORT OFTOP RUNNER TO ALLOW FORDEFLECTION, DO NOT FASTENGYP BD TO RUNNERBASE/HEADPARTITIONTAGSTUDSIZESTUDGAUGESTUDSPACINGMAX HT (5 PSF)L/240 L/360MAX HT (10 PSF)L/240 L/360FIRE RATING/TEST NOACOUSTIC PROPERTIES WALLTHKSTC INSUL THK TEST NOCONT ACOUSTICAL SEALANT OFFASTENER2" MIN1/2"26A 3-5/8" 25 GA 24" 7'-6" 6'-7" -- -- 2HR/UL DES U493 65 3 1/2" SEE NOTE 10-3/4"5/8" (12" WIDTH) GYP BDCROSS BRACING 4'-0" OCVERTICAL SPACING MAXSOUND ATTENUATION BLANKETLINE OF STRUCTUREPLANMETAL STUD(3) LAYERS 5/8" FIRERATED GYP BD EA FACECONT SEALANTCUT STUDS 1/2" SHORT OFTOP RUNNER TO ALLOW FORDEFLECTION, DO NOT FASTENGYP BD TO RUNNERBASE/HEADPARTITIONTAGSTUDSIZESTUDGAUGESTUDSPACINGMAX HT (5 PSF)L/240 L/360MAX HT (10 PSF)L/240 L/360FIRE RATING/TEST NOACOUSTIC PROPERTIES WALLTHKSTC INSUL THK TEST NOCONT SEALANT OFFASTENER2" MIN1/2"28C 2-1/2" 25 GA 24" 11'-6" 10'-1" -- -- 3 HR/UL DES U419 50 -- --6-1/4"28D 3-5/8" 25 GA 24" 13'-9" 12'-10 -- -- 3 HR/UL DES U419 50 -- --7-3/8"28F 6" 25 GA 24" 18'-10" 16'-9" -- -- 3 HR/UL DES U419 50 -- --9-3/4"28G 2-1/2" 20 GA 24" 11'-10" 10'-5" -- -- 3 HR/UL DES U419 50 -- -- 6-1/4"28H 3-5/8" 20 GA 24" 14'-3" 12'-6" -- -- 3 HR/UL DES U419 50 -- -- 7-3/8"28K 6" 20 GA 24" 20'-4" 17'-11" -- -- 3 HR/UL DES U419 50 -- -- 9-3/4"28J 4" 20 GA 24" 15'-2" 13'-3" -- -- 3 HR/UL DES U419 50 -- -- 7-3/4"28E 4" 25 GA 24" 14'-6" 12'-11" -- -- 3 HR/UL DES U419 50 -- --7-3/4"NOTE: STC 50 IS ESTIMATEDLINE OF STRUCTUREPLANMETAL "C-H" STUD(3) LAYERS 5/8" FIRE RATEDGYP BDCONT SEALANTCUT STUDS 1/2" SHORT OFTOP RUNNER TO ALLOW FORDEFLECTION, DO NOT FASTENGYP BD TO RUNNERBASE/HEADPARTITIONTAGSTUDSIZESTUDGAUGESTUDSPACINGMAX HT (5 PSF)L/240 L/360MAX HT (10 PSF)L/240 L/360FIRE RATING/TEST NOACOUSTIC PROPERTIES WALLTHKSTC INSUL THK TEST NOCONT SEALANT OFFASTENER2" MIN1/2"27L 2-1/2" CH 25 GA 24" OC 11'-5" 10'-0" 9'-1" 7'-11" 3 HR/UL DES U415 39 -- -- 4-3/8"1" SHAFT WALL LINERMTL "J" RUNNERMTL "J" RUNNER27M 4" CH 25 GA 24" OC 14'-8" 12'-10" 11'-8" 10'-2" 3 HR/UL DES U415 39 -- --5-7/8"27N 2-1/2" CH 20 GA 24" OC 13'-6" 11'-9" 10'-9" 9'-4" 3 HR/UL DES U415 39 -- -- 4-3/8"27P 4" CH 20 GA 24" OC 18'-9" 16'-5" 14'-11" 13'-0" 3 HR/UL DES U415 39 -- --5-7/8"27Q 6" CH 20 GA 24" OC 26'-4" 23'-0" 20'-5" 18'-3" 3 HR/UL DES U415 39 -- --7-7/8"NOTE: STC 39 IS ESTIMATEDLINE OF STRUCTURE 3" = 1'-0"232 HR SHAFT WALL ACOUSTIC PARTITION - FINISHED TWO SIDES 3" = 1'-0"242 HR CHASE WALL GYP BOARD PARTITION01/2"1"2"SheetTitleApprovedCheckedDrawnJob NumberDateSheet InformationRevisionsMEP FPME Engineers29 West 38th Street, 5th FloorNew York, NY 10018t 212.447.6770f 212.447.6615STRUCTURAL ENGINEER/SUSTAINABILITY CONSULTANTThornton Tomasetti51 Madison Ave.New York, N.Y. 10010t 917.661.7800f 917.661.7801LIGHTING CONSULTANTLumen Architecture214 W 29th Street Suite 1005New York, NY 10001t 212.564.6469f 917.591.2524LANDSCAPE ARCHITECTTrowbridge Wolf Michaels1001 West Seneca Street Suite 101Ithaca, NY 14850t 607.277.1400f 000.000.0000162345AEBCD162345AEBCDCopyright © 2013 Perkins+Will227 West 29th Street, 7th Flr.New York, NY 10001t: 212 505-5955f: 212 505-1648CIVIL ENGINEERTG Miller PC203 North Aurora StreetIthaca, NY 14850t 607.272.6477f 607.273.6322AV / ACOUSTICSThe Sextant Group244 Madison Avenue Suite 311New York NY 10016t 877.684.2311f 412.323.8538CODE CONSULTANTCode Consultants ProfessionalEngineers, PC215 West 40th Street 15th FloorNew York, NY 10018t 212.216.9596f 212.216.96193/31/2015 4:18:15 PMc:\temp\Upson Hall _ ARCH_sobeskic.rvtA-6101PARTITION TYPESCHEDULE ANDDETAILSCAS/WCMDC/CW031549.00002/27/2015RWGUpson HallRenovation124 Hoy Rd, Ithaca, NY 14850CornellUniversity215 Park Avenue South4th FloorNew York, NY 10003t 212.251.7000f 212.251.7111www.perkinswill.comNOTUSED 3" = 1'-0"25DOUBLE STUD ACOUSTIC GYP BOARD PARTITION 3" = 1'-0"262 HR DOUBLE STUD ACOUSTIC GYP BOARD PARTITIONNO ISSUE DATE1 100% DD DOCUMENTS 14/08/282 50% CONSTRUCTIONDOCUMENTS14/11/073 BID SET 15/02/274 ADDENDUM NO 3 15/03/31 3" = 1'-0"283 HR TRIPLE LAYER BALANCED GYP BOARD PARTITION 3" = 1'-0"273 HR SHAFT WALL PARTITION - FINISHED ONE SIDE