Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
_Conformed Set Volume 1 351
LEVEL 0212' - 4"R.3EXISTING WALL ASSEMBLYNEW 3 HOUR RATED WALLTYPE 27P, REF SHEETA-6101VIF5' - 5 1/2" EXISTING WINDOW8' -0"B/O CEILING3 HOUR RATED COUNTERFIRE DOOR INSTALLEDBETWEEN JAMBS.MOUNT HOOD ABOVECEILINGACT-1 SUSPENSION GRIDFAN COIL UNIT AND METALENCLOSURE, SEE SHEET A-5300FOR DETAILS, FINISH TO MATCHWINDOW FRAME2' - 9 1/4"6' - 4"BOTTOM BARLEVEL 0212' - 4"88.18' -2"B/O CEILINGFAN COIL UNIT AND METALENCLOSURE, SEE SHEETA-5300 FOR DETAILS, FINISHTO MATCH WINDOW FRAME5/8" GYPSUM BOARDOVER SUSPENSION GRIDNEW 3 HOUR RATED WALL TYPE27P, REF SHEET A-6101EXISTING WALL ASSEMBLY5/8" PLYWOOD, PAINTEDEXISTING WINDOW5' - 5 1/2"2' - 9 1/4"EXISTING CONCRETE BEAMBLOCKING ANDVERTICAL FRAMINGR.35' - 8" NEW OPENINGNEW 3 HOUR RATEDWALL TYPE 27P, REFSHEET A-6101LINE OF FIRE CURTAINHOOD ABOVE CEILINGSTL. GUIDE FASTENED TO JAMB3 HOUR RATED COUNTERFIRE DOOR.EXISTING WALL ASSEMBLYEXISTING WINDOWLEVEL 0212' - 4"6' - 4" NEW OPENING FOR FIRE DOORVIF2' - 9 1/4" EXIST. WINDOW SILL HEIGHTFAN COIL ENCLOSURELINE OF WINDOW BEYOND3 HOUR RATED COUNTERFIRE DOOR INSTALLEDBETWEEN JAMBS.MOUNT HOOD ABOVE CEILING8' -0"B/O CEILINGACT-1 SUSPENSION GRID01/2"1"2"SheetTitleApprovedCheckedDrawnJob NumberDateSheet InformationRevisionsMEP FPME Engineers29 West 38th Street, 5th FloorNew York, NY 10018t 212.447.6770f 212.447.6615STRUCTURAL ENGINEER/SUSTAINABILITY CONSULTANTThornton Tomasetti51 Madison Ave.New York, N.Y. 10010t 917.661.7800f 917.661.7801LIGHTING CONSULTANTLumen Architecture214 W 29th Street Suite 1005New York, NY 10001t 212.564.6469f 917.591.2524LANDSCAPE ARCHITECTTrowbridge Wolf Michaels1001 West Seneca Street Suite 101Ithaca, NY 14850t 607.277.1400f 000.000.0000162345AEBCD162345AEBCDCopyright © 2013 Perkins+Will227 West 29th Street, 7th Flr.New York, NY 10001t: 212 505-5955f: 212 505-1648CIVIL ENGINEERTG Miller PC203 North Aurora StreetIthaca, NY 14850t 607.272.6477f 607.273.6322AV / ACOUSTICSThe Sextant Group244 Madison Avenue Suite 311New York NY 10016t 877.684.2311f 412.323.8538CODE CONSULTANTCode Consultants ProfessionalEngineers, PC215 West 40th Street 15th FloorNew York, NY 10018t 212.216.9596f 212.216.96193/31/2015 5:56:22 PMA-5301INTERIOR DETAILS- ATRIUMSEPARATIONCheckerAuthor031549.00002/27/2015ApproverUpson HallRenovation124 Hoy Rd, Ithaca, NY 14850CornellUniversity215 Park Avenue South4th FloorNew York, NY 10003t 212.251.7000f 212.251.7111www.perkinswill.comNO ISSUE DATE4 ADDENDUM NO 3 15/03/31 1 1/2" = 1'-0"C2ATRIUM WINDOW W/ SHUTTERS SECTION 1 1/2" = 1'-0"C4ATRIUM WINDOW SECTION 1 1/2" = 1'-0"A4ATRIUM WINDOW PLAN DETAIL 1" = 1'-0"A2SHUTTER ELEVATION