APPLICABLE CODES FOR UPSON HALLNY STATE BUILDING CODE 2010, INCORPORATING AND AMENDING THE FOLLOWING:BC NYS BUILDING CODES NEW YORK STATE-2010 EDITIONEBC NYS EXISTING BUILDING CODE NEW YORK STATE-2010 EDITIONPC NYS PLUMBING CODES NEW YORK STATE-2010 EDITIONMC NYS MECHANICAL CODE NEW YORK STATE-2010 EDITIONFGC NYS FUEL GAS CODE NEW YORK STATE-2010 EDITIONECC NYS ENERGY CONSERVATION CODE NEW YORK STATE-2010 EDITIONFC NYS FIRE CODE NEW YORK STATE-2010 EDITIONREFERENCED CODES IN NYS BUILDING CODE:NFPA 70 NATIONAL ELECTRIC CODE -2008 EDITIONNFPA 72 NATIONAL FIRE ALARM CODE-2007 EDITIONNFPA 13 INSTALLATION OF SPRINKLER SYSTEM-2007 EDITIONNEW YORK STATE DEPARTMENT OF ENVIRONMENTAL CONSERVATION INCLUDING: AIR EMISSIONS, FLOOD PLAIN, STORM WATERICC/ANSI A117.1-2003 AS REFERENCED BY THE NYS UNIFORM FIRE PREVENTION AND BUILDING CODETOILET FIXTURE REQUIREMENTS PER TABLE 2902.01 OF THE 2010 BUILDING CODE OFNEW YORK STATEOCCUPANCYA-3WATERCLOSETSMALE FEMALE1 PER 125 1 PER 65LAVS DRINKINGFOUNTAINS1 PER 200 1 PER 500SERVICESINK1BATHTUB/SHOWERN/AB 1 PER 25 FOR THE FIRST 50AND 1 PER 50 FOR THEREMAINDER EXCEEDING 501 PER 100 1N/A1 PER 200MALE FEMALE1 PER 25 FOR THE FIRST 50AND 1 PER 50 FOR THEREMAINDER EXCEEDING 501 PER 40 FOR THE FIRST 80AND 1 PER 80 FOR THEREMAINDER EXCEEDING 801 PER 40 FOR THE FIRST 80AND 1 PER 80 FOR THEREMAINDER EXCEEDING 8001/2"1"2"SheetTitleApprovedCheckedDrawnJob NumberDateSheet InformationRevisionsMEP FPME Engineers29 West 38th Street, 5th FloorNew York, NY 10018t 212.447.6770f 212.447.6615STRUCTURAL ENGINEER/SUSTAINABILITY CONSULTANTThornton Tomasetti51 Madison Ave.New York, N.Y. 10010t 917.661.7800f 917.661.7801LIGHTING CONSULTANTLumen Architecture214 W 29th Street Suite 1005New York, NY 10001t 212.564.6469f 917.591.2524LANDSCAPE ARCHITECTTrowbridge Wolf Michaels1001 West Seneca Street Suite 101Ithaca, NY 14850t 607.277.1400f 000.000.0000162345AEBCD162345AEBCDCopyright © 2013 Perkins+Will227 West 29th Street, 7th Flr.New York, NY 10001t: 212 505-5955f: 212 505-1648CIVIL ENGINEERTG Miller PC203 North Aurora StreetIthaca, NY 14850t 607.272.6477f 607.273.6322AV / ACOUSTICSThe Sextant Group244 Madison Avenue Suite 311New York NY 10016t 877.684.2311f 412.323.8538CODE CONSULTANTCode Consultants ProfessionalEngineers, PC215 West 40th Street 15th FloorNew York, NY 10018t 212.216.9596f 212.216.96193/31/2015 4:19:40 PMc:\temp\Upson Hall _ ARCH_sobeskic.rvtLS-0002CODE SUMMARYCASAHS031549.00002/27/2015RWGUpson HallRenovation124 Hoy Rd, Ithaca, NY 14850CornellUniversity215 Park Avenue South4th FloorNew York, NY 10003t 212.251.7000f 212.251.7111www.perkinswill.comGENERAL REQUIREMENTSCODE TOPICREQUIREMENTBC NYS EBC NYS FC NYSSPRINKLER PROTECTION UPSON AND GRUMMAN HALLS PROTECTED WITH APPROVED SUPERVISED AUTOMATIC SPRINKLER SYSTEM.NFPA 13DEFINITION OF BUILDING UPSON, DUFFIELD, PHILLIPS AND GUMMAN ARE CONSIDERED A SINGLE BUILDING. THIS PROJECT INCLUDES RENOVATIONS TO UPSON HALL.CLASSIFICATION OF WORK THE WORK AREA COMPLIANCE METHOD WILL BE USED FOR THIS PROJECT.RENOVATION: WORK AT UPSON HALL WILL BE CLASSIFIED AS LEVEL 2 ALTERATIONS: UPSON, DUFFIELD, PHILLIPS AND GRUMMAN ARE CONSIDERED ASINGLE BUILDING SO TOTAL WORK AREA = <50%NEW: THE PROPOSED PROJECT WILL INCLUDE TWO SMALL ADDITIONS.CH. 4-12CHANGE OF OCCUPANCY THE PROJECT WILL INCREASE CLASSROOM AREAS TO MORE THAN 750 SF WITH MORE THAN 50 OCCUPANTS. CH. 9OCCUPANCY CLASSIFICATION NON-SEPARATED MIXED USE: A-3, ASSEMBLY: CLASSROOMS, CONFERNCE AND MULTI-PURPOSE ASSEMBLY SPACES WITH MORE THAN 50 PERSONS OR>750SFB, BUSINESS: OFFICES, CLASSROOMS, LABORATORIES, CONFERENCE AND MULTI-PURPOSE ASSEMBLY SPACES WITH LESS THAN 50 PERSONS OR <750SFACCESSORY OCCUPANCIES: S-2, LOW HAZARD STORAGE AND S-1, MODERATE HAZARD STORAGE: OCCUPIES <10% OF FLOOR AREA ON WHICH THEY ARELOCATED, AND ARE CONTAINED IN CONTROL AREA (SEE BELOW).303, 304, 311508.3, 508.3.1SEPARATION WITHIN ENTIREBUILDINGALL EXISTING FIRE SEPARATIONS WILL BE MAINTAINED. THERE IS AN EXISTING 1 HOUR ATRIUM SEPARATION BETWEEN UPSON AND DUFFIELD. 508.3CONTROL AREA LABORATORY SPACES WILL CONTAIN A LIMITED AMOUNT HAZARDOUS MATERIALS, NOT EXCEEDING QUANTITIES OUTLINED IN TABLES 307.1(1) AND307.1(2), AND WILL BE ENCLOSED IN A CONTROL AREA COMPLYING WITH SECTION 414.Table307.1(1),Table307.1(2), 414CONSTRUCTION TYPE THE CONSTRUCTION TYPE OF THE EXISTING BUILDING IS TYPE IB PER THE NEW YORK STATE UNIFORM FIRE PREVENTION AND BUILDING CODE (UFPBC),DATED 1995. NEW ADDITIONS ARE TYPE IA. SINCE TYPE IB PER UFPBC IS MORE RESTRICTIVE THAN CURRENT CODE, THE PROJECT IS CLASSIFIED AS TYPEIA CONSTRUCTION.503HEIGHT AND AREA THE WORK INCLUDES A CHANGE IN OCCUPANCY CLASSIFICATION FROM B TO A-3 (EBC TABLE 912.5) SO THE HEIGHT AND AREA MUST COMPLY WITH THECURRENT BUILDING.503 912.5,1002.2MAXIMUM BUILDING HEIGHT ANDAREAAN ADDITION MUST NOT INCREASE THE HEIGHT AND AREA OF AN EXISTING BUILDING BEYOND THAT PERMITTED FOR A NEW BUILDING. BASED ON GROUPA-3 OCCUPANCY: HEIGHT<160' (+ 20 FT IN SPRINKLERED BLDG) AND 11 STORIES (+1 STORY IN SPRINKERLED BLDG). AREA=UNLIMITED.ACTUAL = 5 STORIES AND DOES NOT EXCEED HEIGHT OR AREA LIMITATIONS.Table 503,504.2CONTROL AREA EXHAUST EXHAUST FROM CONTROL AREAS CAN ONLY COMBINE IN DEDICATED SHAFTS. CERTAIN MATERIALS REQUIRE SPECIAL PROVISIONS. MechanicalCode 510.4LEVEL AT GRADE LEVEL 00 IS CONSIDERED AS A STORY ABOVE GRADE PLANE - LEVEL 01 FINISHED SURFACE IS MORE THAN 12' A.F.F. ON WESTERN SIDE OF BUILDING. 502.1FIRE RESISTANT RATING REQUIREMENTSEXTERIOR NONBEARING WALLS -SEPARATION DISTANCE <30' FROMIMAGINARY LOT LINE (SEE SHEETG-0010)BC NYS TYPE IA, OCC. A: 1 HR REQUIRED,Table 602,Table 601EXTERIOR NONBEARING WALLS -SEPARATION DISTANCE >30' FROMIMAGINARY LOT LINE (SEE SHEETG-0010)BC NYS TYPE IA, OCC. A: 0 HR REQUIRED,Table 602,Table 601STRUCTURAL FRAME BC NYS TYPE IA: 3 HR REQUIRED; 3 HR PROVIDEDTable 601BEARING WALLS BC NYS TYPE IA: 3 HR REQUIRED; 3 HR PROVIDEDTable 601FLOOR ASSEMBLY BC NYS TYPE IA: 2 HR REQUIRED; 2 HR PROVIDEDTable 601ROOF CONSTRUCTION INCLUDINGSUPPORTING BEAMSBC NYS TYPE IA: 1-1/2 HR REQUIRED; 1-1/2 HR PROVIDEDTable 601MAXIMUM PERMITED PROTECTEDOPENINGS IN EXTERIOR WALLS(SPINKLERED BLDG)BASED ON FIRE SEPARATION DISTANCE: <3'=NOT PERMITTED, >3' TO 5'= 15%, >5' TO 10'=25%, >10' TO 15'=45%, >15' TO 20'=75%, >20'=NO LIMIT. PLACEIMAGINARY LOT LINE SO ADJACENT SEPARATE BLDGS, KIMBALL HALL OR RHODES HALL REMAIN COMPLIANT WITH RESPECT TO EXISTING EXTERIOR WALLRATING AND AMOUNT OF OPENINGS.Table 704.8FIRE BARRIER: NEW FLOOROPENINGS AND SHAFTS2 HR REQUIREDNOT REQUIRED FOR 2 STORY OPENINGS WHEN OPENING: IS NOT PART OF REQUIRED MEANS OF EGRESS; IS NOT CONCEALED WITHIN BUILDINGCONSTRUCTION; IS NOT OPEN TO NONSPINKLERED FLOORS; IS SEPARATED FROM FLOOR OPENINGS SERVING OTHER FLOOR BY CONSTRUCTIONCONFORMING TO REQUIRED SHAFT ENCLOSURES.706.3.1,707.4, 707.2Exception 7FIRE BARRIER: EXISTING FLOOROPENINGS AND SHAFTS1 HR REQUIRED. VERIFY THAT EXISTING CONSTRUCTION COMPLIES.703.2FIRE BARRIER: EXIT STAIRENCLOSURES2 HR REQUIRED FOR STAIRS 4 STORIES OR MORE; 2 HR PROVIDED706.3.2,1020.1FIRE BARRIER: CONVENIENCESTAIR2 HR FIRE CURTAIN AT BASEMENT. GROUP A OCCUPANCIES WILL NOT BE LOCATED IN THE SAME FIRE AREA AS THE CONVENIENCE STAIR, SO OPENING ISPERMITTED TO CONNECT ALL FIVE STORIES.706.3.1, 707.2Exception 2.1FIRE BARRIER: SEPARATION OFOCCUPANCIESNO SEPARATION BETWEEN OCCUPANCIES.706.3.8, Table508.3FIRE BARRIER: CONTOL AREA PROTECTED BY A FIRE RATED ASSEMBLY PER TABLE 414.2.2: LEVELS 00-03 = 1HR FIRE BARRIER; LEVELS 04-05 = 2HR FIRE BARRIER. CONSTRUCTIONSUPPORTING FLOORS = MIN. 2HR.706.3.7, Table414.2.2FIRE BARRIER: INCIDENTAL USEAREASBASEMENT LEVEL: 2 HR PROTECTION OF ELECTRICAL ROOMS IN N.E. CORNER, GENERATOR ROOM, AND FIRE PUMP ROOM. 1 HR PROTECTION OFMECHANICAL ROOM IN N.E. CORNER.ELEVATOR LOBBY ENCLOSED ELEVATOR LOBBY NOT REQUIRED IN SPRINKLERED BUILDING.707.14.1Exception 4FIRE-RESISTANT JOINT SYSTEMS WILL COMPLY713FIRE-RESISTANT RATING OFSTRUCTURAL MEMBERSWILL COMPLY714EGRESS REQUIREMENTSEXISTING MEANS OF EGRESS MEANS OF EGRESS WILL COMPLY WITH CURRENT BUILDING CODE. EXISTING STAIRWAYS ARE PERMITTED FOR CONTINUED USE. GRUMMAN HALL MUSTEGRESS THROUGH UPSON ON LEVELS 01 AND 02.705GENERAL MEANS OF EGRESS CEILING HEIGHT > 7'-6" (NEW CONSTRUCTION) EXISTING CEILINGS BELOW 7'-6" PERMITTED TO REMAIN; MIN. HEADROOM = 80" IF <50% OF EGRESS CLGAREA1003, 1003.2,1003.3.1OCCUPANT LOAD FACTOR:ASSEMBLY, UNCONCENTRATEDTABLE AND CHAIRS15 NSF /OCC.Table1004.1.1OCCUPANT LOAD FACTOR:CLASSROOMS & READING ROOMS20 NSF /OCC.Table1004.1.1OCCUPANT LOAD FACTOR:LABORATORIES50 GSF /OCC.Table1004.1.1OCCUPANT LOAD FACTOR:OFFICES100 GSF /OCC.Table1004.1.1OCCUPANT LOAD FACTOR:STORAGE300 GSF /OCC.Table1004.1.1BENCH SEATING IN CORRIDORS 1 PERON PER 18" OF SEATING LENGTH1004.7MINIMUM NUMBER OF EXITS NOT LESS THAN 2; 2 IF <500 OCCUPANTS/ FLOOR; 3 IF 501-1000 OCCUPANTS/FLOOR; 4 IF >1000 OCCUPANTS/FLOOR; PROVIDE 3 TO NOT EXCEED MAXTRAVEL DISTANCE1019, Table1019.1EGRESS WIDTH PER OCCUPANTSERVED (SPINKLERED BLDG)STAIRWAYS= 0.2" /PERSON, OTHER EGRESS COMPONENTS= 0.15" /PERSONTable 1005.1EGESS CONVERGENCE EGRESS FROM THE BASEMENT AND 2ND LEVELS CONVERGE AT THE 1ST LEVEL. AT POINT OF CONVERGENCE, OCCUPANT LOAD = SUM OF OCCUPANTLOAD FROM BOTH LEVELS.1004.5MULTIPLE OCCUPANCIES WHEN AN AREA CONTAINS TWO OR MORE OCCUPANCIES, THE SHARED MEANS OF EGRESS COMPONENTS SHALL MEET THE MORE STRINGENTREQUIREMENTS OF ALL OCCUPANCIES THAT ARE SERVED.1004.9ACCESSIBLE MEANS OF EGRESSREQUIREDYES. ACCESSIBLE SPACES MUST BE PROVIDED WITH NOT LESS THAN 2 MEANS OF EGRESS. THE LANDING OF THE WEST EGRESS STAIR AND THE SOUTHELEVATOR WILL PROVIDE ACCESSIBLE MEANS OF EGRESS.1007.1,1007.2.1ACCESSIBLE MEANS OF EGRESS:ELEVATORELEVATOR SHALL COMPLY WITH EMERGENCY OPERATION AND SIGNALING DEVICE REQUIREMENTS OF SECTION 2.27 ASME A17.1. PROVIDE STANDBYPOWER. MUST BE ACCESSED BY EITHER AN AREA OF REFUGE OR HORIZONTAL EXIT.1007.4ACCESSIBLE MEANS OF EGRESS:STAIRWELLPROTECTED WEST STAIRWELL SHALL INCORPORATE AN AREA OF REFUGE WITHIN AN ENLARGED FLOOR LEVEL LANDING ON ALL FLOORS EXCEPT FORLEVEL OF DISCHARGE. THE BLDG IS FULLY SPRINKLERED, SO STAIR IS NOT REQUIRED TO HAVE A CLEAR WIDTH OF 48".1007.3,Exception 3AREA OF REFUGE CRITERIA DISTANCE TO AREAS OF REFUGE SHALL NOT EXCEED MAXIMUM TRAVEL DISTANCE FOR OCCUPANCY (SEE BELOW). A TWO WAY COMMUNICATION SYSTEMIS REQUIRED AT EACH AREA OF REFUGE. AREA MUST BE SIZED TO ACCOMODATE 1 WHEELCHAIR SPACE OF 30" BY 48" FOR EVERY 200 OCCUPANTS.1007.6,1007.6.1,1007.6.3AREA OF REFUGE SMOKEBARRIEREACH AREA OF REFUGE SHALL BE PROTECTED BY A 2 HOUR FIRE BARRIER AND A SMOKE BARRIER. OPENINGS IN THIS CONSTRUCTION MUST COMPLYWITH THE MOST RESTRICTIVE REQUIREMENTS.1007.6.2, 709,715MINIMUM NUMBER OF EXITS FORINTERIOR SPACES, TYPE A OR BOCCUPANCY2 EXITS REQUIRED IN SPACES WITH OCCUPANT LOAD >49 OR TRAVEL DISTANCE >75'. IN SPRINKLERED BUILDINGS, PATH OF TRAVEL FOR GROUP B ISPERMITTED TO INCREASE TO 100'Table 1015.1,1014.3MAXIUMUM EXIT ACCESS TRAVELDISTANCESPRINKLERED BLDG (UPSON): B OCCUPANCY= 300'; A-3 OCCUPANCY=250'Table 1016.1CORRIDOR FIRE RESISTANCERATING (SPRINKLERED BLDG)0 HR FOR OCCUPANCY GROUPS A AND B. EGRESS CORRIDORS SERVING GRUMMAN SHALL BE 2 HR RATED. Table 1017.1DEAD END CORRIDOR MAXIMUM OCCUPANCY A=20', OCCUPANCY B=50'1017.3 705.6MINIMUM CORRIDOR WIDTH 44 INCHES1017.2EGRESS STAIR: USE OF EXISTINGSTAIRNO ALTERATIONS WILL BE DONE TO THE EXISTING ENCLOSED EGRESS STAIRS. EGRESS ALLOWANCES WILL BE BASED ON THE MOST RESTRICTIVEELEMENT OF THE STAIR.706EGRESS STAIR: VESTIBULE OPENINGS ARE NOT PERMITTED FROM NORMALLY UNOCCUPIED SPACES, SUCH AS MECHANICAL ROOMS. A STAIR VESTIBULE IS PROVIDED AT THE TOPLEVEL OF EGRESS STAIR N AND EGRESS STAIR S.1020.1.1MINIMUM STAIR WIDTH 44 INCHES1017.2MINIMUM DOOR WIDTH ANDHEIGHTMUST BE SUFFICIENT FOR OCCUPANT LOAD. MIN 32" CLEAR OF STOP AND DOOR IN 90 DEG OPEN POSITION, EXCEPT AT STORAGE CLOSETS <10 SF HAVENO MIN WIDTH. DOOR HEIGHT SHALL NOT BE LESS THAN 80 IN.1008.1.1DOOR SWING DOORS SHALL SWING IN THE DIRECTION OF EGESS TRAVEL WHERE SERVING AN OCCUPANT LOAD OF >50 PEOPLE. 1008.1.2ACCESS CONTROL DOORS MUST BE EQUIPPED WITH APPROVED ENTRANCE AND EGRESS ACCESS CONTROL SYSTEM. 1008.1.3.4THRESHOLDS SHALL NOT EXCEED 0.5"1008.1.6HOSPITAL / SERVICE ELEVATOR THE FREIGHT ELEVATOR SHALL BE UPGRADED AND EXTENDED WITH AN ELEVATOR THAT ACCOMODATES AN AMBULANCE STRETCHER AND PROVIDESFIRE DEPARTMENT ACCESS TO ALL FLOORS3002.4AREA (GROSS WORK AREA)Level AreaLEVEL 00 29,386 SFLEVEL 01 28,724 SFLEVEL 02 27,585 SFLEVEL 03 27,528 SFLEVEL 04 27,544 SFLEVEL 05 19,549 SFLEVEL 06 3,750 SFTOTAL 164,067 SFUPSON OCCUPANCYLevel OccupancyType OccupancyLoadLEVEL 03LEVEL 03 B 434LEVEL 03 S2 1435LEVEL 04LEVEL 04 B 427LEVEL 04 S2 1428LEVEL 05LEVEL 05 B 274LEVEL 05 S2 1275TOTAL 2,998UPSON OCCUPANCYLevel OccupancyType OccupancyLoadLEVEL 00LEVEL 00 A3 349LEVEL 00 B 249LEVEL 00 S2 14612LEVEL 01LEVEL 01 A3 357LEVEL 01 B 232LEVEL 01 S2 1590LEVEL 02LEVEL 02 A3 285LEVEL 02 B 372LEVEL 02 S2 1658FIRE PROTECTION EQUIPMENTFIRE EXTINGUISHERS REQUIRED IN NEW AND EXISTING GROUP A AND B OCCUPANCIES, AND SPECIAL-HAZARD AREAS. MAXIMUM TRAVEL DISTANCE = 75' 906.1 906.1Table906.3(1)MEANS OF EGRESS ILLUMINATION THE MEANS OF EGRESS ILLUMINATION LEVEL SHALL NOT BE LESS THAN 1 foot-candle (11 lux) AT THE WALKING LEVEL SURFACE. 1006.2UPSON HALL CODE SUMMARYGRUMMAN OCCUPANCYLevel OccupancyType OccupancyLoadLEVEL 00 GRUMMAN 101LEVEL 01 GRUMMAN 71LEVEL 02 GRUMMAN 83TOTAL 255ECCCNYS COMPLIANCE STATEMENT“TO THE BEST OF MY KNOWLEDGE, BELIEF AND PROFESSIONAL JUDGMENT, THESE PLANS ANDSPECIFICATIONS ARE IN COMPLIANCE WITH THE ENERGY CONSERVATION CONSTRUCTION CODE OF NEWYORK STATE 2014, USING CHAPTER 5 - COMMERCIAL ENERGY EFFICIENCY."AREA (GROSS BUILDING)WORK AREA - UPSON HALL BUILDING AREA -UPSON, GRUMMAN,PHILLIPS & DUFFIELDAPPROX. 427, 173 SFNO ISSUE DATE3 BID SET 15/02/274 ADDENDUM NO 3 15/03/31