Loading...
HomeMy WebLinkAbout_Conformed Set Volume 1 267COL.ROOF DRAINPIPING INSULATION SEALEDTO UNDERSIDE OF DECKINGDRAIN STRAINERSET TOP OF OVERFLOW SLEEVE2" ABOVE ROOF DRAIN ELEVATIONCLAMPING RINGDECK CLAMPDRAIN BOWLPIPING INSULATION ATUNDERSIDE OF DRAINBOWL AND LEADERSLOPE 1/4":1'EPDM SEALING MASTICINSULATIONTAPERED18” (450 MM) AROUND DRAINFASTENERAND PLATE, 12” (300 MM) O.C.EPDM SEALINGMASTICEPDM MEMBRANEEPDM MEMBRANEBONDING ADHESIVEROOF DRAIN2' - 0"PIPE BOOTMULTIPLE PENETRATIONCOVERFASTENING PLATE STRIPATTACHED @ 12" O.C.T.O.S. ROOFEPDM MEMBRANE FLASHINGEPDM BONDING ADHESIVE3" MIN WIDE TAPE IN CONJUNCTIONWITH EPDM PRIMERVENT PIPESEALANTFLASHNG UMBRELLASET IN ADHESIVES.S. FLASHING SET INADHESIVESEAM EDGE TREATMENTT.O.S. ROOFVAPOR BARRIER TO SEAL ALLPENETRATIONS, TYP.ROOF HATCHFIBERGLASS INSULATIONEPDM MEMBRANE FLASHINGEPMD BONDING ADHESIVESTRUCTURAL STEEL REFERTO STRUCTURAL DWGSLADDER3" MIN WIDE TAPE IN CONJUNCTIONWITH EPDM PRIMERT.O.S. ROOFEPDM MEMBRANESTEEL SUPPORTSHEET METAL COUNTERFLASHING TO BE SEALED WATER-TIGHTEPDM BONDING ADHESIVETAPEEPDM MEMBRANE FLASHINGEPDM MEMBRANEROOF DRAINOVERFLOW DRAIN2' - 0"TYP.SUMP1' - 0"INSPECTION BOX WITHREMOVEABLE COVERPERFORATED METALEDGEGRAVEL EDGEEPDM BONDING ADHESIVEEPDM MEMBRANEEPDM MEMBRANE ADHERED TOSUBSTRATEFOAM ROD DIA. 1.5XLARGER THAN MAXIMUM GAPCOMPRESSIBLEFILLER6" WIDE PRESSURE SENSITIVE RUSSFASTENER ANDPLATE 12” O.C. MAXIMUMT.O.S. ROOFMAXIMUM2"POLYESTER MAT PROTECTIONMATERIALEPDM MEMBRANEEPDM BONDING ADHESIVEPERFORATED METAL EDGET.O.S. ROOFGUARD SUPPORT POSTFLASH POST AT BASE WITH CLAMPING RINGEPDM MEMBRANE FLASHINGEPDM MEMBRANEFASTENER AND PLATE12” (300 MM) O.C. MAXIMUMEPDM BONDINGADHESIVE3" MIN WIDE TAPE INCONJUNCTION WITH EPDMPRIMEREPDM BONDING ADHESIVEMETAL COPINGT.O.S. ROOF1/8" MIN - 1/2" MAXEPDM PRIMER ANDREINFORCING FABRICAIR / VAPORBARRIER2“MAXIMUMFASTENER AND PLATE 12” (300 MM) O.C. MAXIMUMWITH CONTINUOUS WELDS BETWEEN THEMFOAM ROD DIA. 1.5 TIMESLARGER THAN MAXIMUM GAPCOMPRESSIBLEFILLER (MUST BE SUPPORTED)EPDM MEMBRANE6" WIDE PRESSURESENSITIVE RUSSEPDM BONDINGADHESIVET.O.S. ROOFWATERPROOFINGFASTENERS6” O.C. MAXIMUMEPDMMEMBRANEWOOD NAILER SECURELYANCHORED TO DECKMETAL CAP3" MIN WIDE TAPE INCONJUNCTION WITH EPDMPRIMERT.O.S. ROOFEPMD BONDING ADHESIVECONTINUOUS EPMD MEMBRANE FLASHINGFASTENER 12”O.C. MAXIMUMEPDM MEMBRANEMETAL COUNTER FLASHINGSINGLE PLY SEALANTSUBSTRATEEPDM BONDING ADHESIVECONTINUOUSWELDEPDM BONDINGADHESIVEEPDMMEMBRANEPIPEDRAW BANDSINGLE PLYCAULKEPDM PIPE BOOTFASTENER AND PLATET.O.S. ROOFSTAINLESS STEELCLAMPING RING8“MINIMUMVENT PIPEWOOD NAILER SECURELYANCHORED TO DECKFASTENER AND PLATE(4) MINIMUMFASTENEREPDM MEMBRANELAP SEALANT RAIN HOOD AND CLAMP WITH CAULKINGT.O.S. ROOFLAP SEALANTPROTECTIVE STRIPOF EPDM1" MIN3" MIN3" MINELASTOFORM FLASHING INCONJUNCTION WITH EPDMPRIMERLAP SEALANTSTAILESS STEELCLAMPING RINGSINGLE PLYCAULKELASTOFORM FLASHING INCONJUNCTION WITH EPDMPRIMER8“MINIMUMLAP SEALANTFASTENER AND PLATEPIPEEPDMMEMBRANET.O.S. ROOF3" MIN3" MIN1/2" MIN1" MINPROTECTIVE STRIP OFEPDM01/2"1"2"SheetTitleApprovedCheckedDrawnJob NumberDateSheet InformationRevisionsMEP FPME Engineers29 West 38th Street, 5th FloorNew York, NY 10018t 212.447.6770f 212.447.6615STRUCTURAL ENGINEER/SUSTAINABILITY CONSULTANTThornton Tomasetti51 Madison Ave.New York, N.Y. 10010t 917.661.7800f 917.661.7801LIGHTING CONSULTANTLumen Architecture214 W 29th Street Suite 1005New York, NY 10001t 212.564.6469f 917.591.2524LANDSCAPE ARCHITECTTrowbridge Wolf Michaels1001 West Seneca Street Suite 101Ithaca, NY 14850t 607.277.1400f 000.000.0000162345AEBCD162345AEBCDCopyright © 2013 Perkins+Will227 West 29th Street, 7th Flr.New York, NY 10001t: 212 505-5955f: 212 505-1648CIVIL ENGINEERTG Miller PC203 North Aurora StreetIthaca, NY 14850t 607.272.6477f 607.273.6322AV / ACOUSTICSThe Sextant Group244 Madison Avenue Suite 311New York NY 10016t 877.684.2311f 412.323.8538CODE CONSULTANTCode Consultants ProfessionalEngineers, PC215 West 40th Street 15th FloorNew York, NY 10018t 212.216.9596f 212.216.96194/7/2015 5:22:06 PMc:\temp\Upson Hall _ ARCH_sobeskic.rvtA-4301ROOF DETAILSCASCAS031549.00002/27/2015RWGUpson HallRenovation124 Hoy Rd, Ithaca, NY 14850CornellUniversity215 Park Avenue South4th FloorNew York, NY 10003t 212.251.7000f 212.251.7111www.perkinswill.com 1 1/2" = 1'-0"B2ROOF DRAIN WITH OVERFLOW SECTION DETAIL - RS-01A 1 1/2" = 1'-0"C3ROOF PENETRATION - MULTIPLE PIPE 1 1/2" = 1'-0"B3ROOF PENETRATION - PENETRATION PIPE 1 1/2" = 1'-0"A4ROOF PENETRATION - ROOF HATCH/SMOKE VENT 1 1/2" = 1'-0"A5ROOF PENETRATION - SUPPORT 1 1/2" = 1'-0"C2DRAIN PENETRATION DETAIL - RS-02A 1 1/2" = 1'-0"D5WALL JOINT 2" MAXIMUM 1 1/2" = 1'-0"A3WALKWAY (CONCRETE PAVER WITH METAL EDGE) 1 1/2" = 1'-0"B5MEMBRANE WALL COVERING 1 1/2" = 1'-0"D4ROOF JOINT 2" MAXIMUM 1 1/2" = 1'-0"B4SUPPORT (HEAVY) 1 1/2" = 1'-0"D1TERMINATION BAR/FLASHING ATTACHMENT 1 1/2" = 1'-0"C5EPDM PIPE BOOT 1 1/2" = 1'-0"D3VENT PIPE (WARM) 1 1/2" = 1'-0"C4FIELD-FABRICATED VENT PIPE FLASHINGNO ISSUE DATE1 100% DD DOCUMENTS 14/08/282 50% CONSTRUCTIONDOCUMENTS14/11/073 BID SET 15/02/275 ADDENDUM NO 5 15/04/08