Loading...
HomeMy WebLinkAbout_Conformed Set Volume 1 250ZN1 E D C GYPSUM BOARD B GYPSUM BOARD A C RTAINWALL WEEP HOLE ALUM FRAMED I LASS DOOR INSULTED GLASS —a. THRESHOLD BEDDED WITH SEALANT LEVEL 01 SECTION DETAIL (ENTRANCE DOOR) 3" = I 1 I 1 I 1 I I I 140 3 = t-0" PLAN DETAIL (VESTIBULE) PVC ISOLATOR TERRACOTTA PANEL 139 3" = /2 /2 PLAN DETAIL (VESTIBULE) TOP UP NEW SLAB ONLY AT THE DOOR AREA EXISTING SLAB ALUM METAL PANEL TO BE OVERLAPPED AND APPLY SEALANT AT THE JOINT INTERIOR FINISH AS SCHEDULED REINFORCEMENT BAR AS REQUIRED 6" THK FIBER GLASS INSULATION KRAFT FACED LIQUID APPLY AIR/ VAPOR BARRIER (PERMEABLE) ACM PANEL 5/8" DENSGLASS BOARD 6" MINERAL WOOL INSULATION ACM PANEL DOUBLE HIEGHT CURTAINWALL 6" THK FIBER GLASS INSULATION KRAFT FACED SEALANT ALUMINUM CURTAIN WALL ALUM METAL PANEL TO BE OVERLAPPED AND APPLY SEALANT AT THE JOINT SEALANT 1/8"THK. METAL PANEL PLAN DETAIL (VESTIBULE) 3" = 11-0" 1 7/8" INN C7,11 TT CURTAINWALL MULLION YKK DOOR DOOR OPENING ;Fa ii EQ EQ 5 16" 1 3/4" DOOR FRAME WIDTH DOOR WIDTH PLAN DETAIL (ENTRANCE DOOR) 3" = 1'-0" /2' INSIDE OF VESTIBULE PLAN DETAIL (VESTIBULE) 3" = 1'-0" INTERIOR FINISH AS SCHEDULED SILICONE SHEET CONTINUOUS METAL PANEL SILICONE TO BE APPLIED BEFORE INSTALLING THE METAL PANEL 7 5 16" /4" CURTAIN WALL WIDTH METAL PANEL 7 C•I 6" MINERAL WOOL INSULATION ALUM FOIL FACED CURTAINWALL 42 PLAN DETAIL (VESTIBULE) 3" = Cs./ SEALANT WITH BACKER ROD ay 1/4" THK. STAINLESS STEEL ANGLE SUPPORT (DEAD LOAD) 1/8" THK. STAINLESS STEEL ANGLE SUPPORT (WIND LOAD) REFER TO SECTION DETAIL FOR LOCATION 1/8" THK, ALUM ANGLE VERTICAL SUPPORT TERRACOTTA TILE CONTINUOUS 1/8 THK, ALUM BENT SUPPORT SHOP ATTACHED 1/8 THK. ALUM PANEL 5/8" DENSGLASS BOARD LIQUID APPLY AIR/ VAPOR BARRIER (PERMEABLE) 6" MINERAL WOOL INSULATION 6" THK FIBER GLASS INSULATION KRAFT FACED COMPATIBLE SILICONE SHEET CURTAINWALL E D C B LTL Lewis.Tsurumaki.Lewis 227 West 29th Street, 7th Flr. New York, NY 10001 t: 212 505-5955 f: 212 505-1648 PERKINS +WILL MEP FP ME Engineers 29 West 38th Street, 5th Floor New York, NY 10018 t 212.447.6770 f 212.447.6615 STRUCTURAL ENGINEER/ SUSTAINABILITY CONSULTANT Thornton Tomasetti 51 Madison Ave. New York, N.Y. 10010 t 917.661.7800 f 917.661.7801 LIGHTING CONSULTANT Lumen Architecture 214 W 29th Street Suite 1005 New York, NY 10001 t 212.564.6469 f 917.591.2524 LANDSCAPE ARCHITECT Trowbridge Wolf Michaels 1001 West Seneca Street Suite 101 Ithaca, NY 14850 t 607.277.1400 f 000.000.0000 CIVIL ENGINEER TG Miller PC 203 North Aurora Street Ithaca, NY 14850 t 607.272.6477 f 607.273.6322 AV / ACOUSTICS The Sextant Group 244 Madison Avenue Suite 311 New York NY 10016 t 877.684.2311 f 412.323.8538 CODE CONSULTANT Code Consultants Professional Engineers, PC 215 West 40th Street 15th Floor New York, NY 10018 t 212.216.9596 f 212.216.9619 Revisions 3 ADDENDUM 5 15/04/08 2 BID SET 15/02/27 1 50% CONSTRUCTION DOCUMENTS 14/11/07 NO ISSUE DATE Sheet Information Date Job Number Drawn Checked Approved Title EXTERIOR WALL DETAILS Sheet A-4207 Copyright © 2013 Perkins+Will