HomeMy WebLinkAbout_Conformed Set Volume 1 246N -
E
D
C
B
A
30
PLASTIC SHIM
1/4" THK. STAINLESS STEEL ANGLE
NON -CURING BUTYL
5/8" DENSGLASS BOARD
LIQUID APPLY AIR/ VAPOR BARRIER
(IMPERMEABLE)
6" MINERAL WOOL INSULATION
SECTION DETAIL
3" =
METAL PANEL
1/8" THK ALUM ANGLE VERTICAL
SUPPORT
1/8" THK. STAINLESS STEEL ANGLE
HORIZONTAL 'Z' GIRT SUPPORT CONTINUOUS
6" MINERAL WOOL INSULATION
1/4" THK. STAINLESS STEEL ANGLE
1/8" THK ALUM ANGLE VERTICAL
SUPPORT
SECTION DETAIL
3" =
1/8" THK. STAINLESS STEEL ANGLE
SILICONE SHEET MEMBRANE
COVER METAL FLASHING
METAL PANEL
1'-9 1/2"
/16" THK. METAL FLASHING
1/8" THK. METAL COPING WITH MINERAL WOOL
INSULATION
MINIMUM 4" WIDE SILICONE SHEET MEMBRANE ONLY
AT THE JOINT
INERA
WOOL INSULATION
SEALANT ON TOP OF SCREW
XPS INSULATION
ROOFING MEMBRANE
9 3/4"
SHIM AS REQUIRED
EXISTING CMU WALL
BALL PENETRATION PERIMETER OF THE CLIP WILL BE
SEALED PER MANUFACTURER RECOMMENDATION
LIQUID APPLY WATER PROOFING
@ PRECAST SHOP
SECTION DETAIL
3" =
2" THK. STONE
REFER TO ROOFING DETAILS
A
A
A
a
i
a
as
A
A
A
a
a
A
a
A
1/4" THK. STAINLESS STEEL ANGLE SUPPORT (DEAD LOAD)
1/8" THK. STAINLESS STEEL ANGLE SUPPORT (WIND LOAD)
REFER TO SECTION DETAIL FOR LOCATION
EXISTING CMU WALL
GENERAL NOTES:
AFTER EXAMINED OF EXISTING CMU, EXISTING WATERPROOFING TO
BE REMOVED, CLEAN AND APPLY NEW AIR/ VAPOR BARRIER
44/145+ 444;
taitt:I: IS H I MiA S REQ I RiE
0)
METAL PANEL
5' - 0" PANEL WIDTH
PLAN DETAIL
3/ 3" = 11_0"
WEEP HOLE
1/8" THK METAL PANEL
PLASTIC SHIM
6" MINERAL WOOL INSULATION
METAL PANEL
33 3" = 1'
ALU
6" MINERAL WOOL INSULATION
1/8" THK. PVC SEPARATOR
1/8" THK ALUM ANGLE VERTICAL
SUPPORT
5' - 0" PANEL WIDTH
SEALANT WITH BACKER ROD
ALL ROUND
TO PROVIDE END DAM AT
BOTH SIDES
SECTION DETAIL (INTERFACED WITH WINDOW)
WINDOW HEIGHT
INTERIOR FINISH AS SCHEDULED
EXISTING CMU WALL
PLASTIC SHIM AT FASTENING POINT
SEALANT
NON -CURING BUTYL
5' - 0" PANEL WIDTH
INTERIOR FINISH AS SCHEDULED
PLAN DETAIL (INTERFACED WITH WINDOW)
3" =1-0"
EXISTING CMU WALL
4'-0"
WINDOW WIDTH
SEALANT WITH BACKER ROD
N-
M
E
D
C
B
LTL
ewis.Tsurumaki.Lewis
227 West 29th Street, 7th Flr.
New York, NY 10001
t: 212 505-5955
f: 212 505-1648
PERKINS
+WILL
MEP FP
ME Engineers
29 West 38th Street, 5th Floor
New York, NY 10018
t 212.447.6770
f 212.447.6615
STRUCTURAL ENGINEER/
SUSTAINABILITY CONSULTANT
Thornton Tomasetti
51 Madison Ave.
New York, N.Y. 10010
t 917.661.7800
f 917.661.7801
LIGHTING CONSULTANT
Lumen Architecture
214 W 29th Street Suite 1005
New York, NY 10001
t 212.564.6469
f 917.591.2524
LANDSCAPE ARCHITECT
Trowbridge Wolf Michaels
1001 West Seneca Street Suite 101
Ithaca, NY 14850
t 607.277.1400
f 000.000.0000
CIVIL ENGINEER
TG Miller PC
203 North Aurora Street
Ithaca, NY 14850
t 607.272.6477
f 607.273.6322
AV / ACOUSTICS
The Sextant Group
244 Madison Avenue Suite 311
New York NY 10016
t 877.684.2311
f 412.323.8538
CODE CONSULTANT
Code Consultants Professional
Engineers, PC
215 West 40th Street 15th Floor
New York, NY 10018
t 212.216.9596
f 212.216.9619
Revisions
4
ADDENDUM 5
15/04/08
3
BID SET
15/02/27
2
50% CONSTRUCTION
DOCUMENTS
14/11/07
1
100% DD DOCUMENTS
14/08/28
NO
ISSUE
DATE
Date
Job Number
Sheet Information
Drawn
Checked
Approved
Title
EXTERIOR WALL
DETAILS
Sheet
A-4205
Copyright 0 2013 Perkins+Will