HomeMy WebLinkAbout_Conformed Set Volume 1 244CV - 1-2" DIMENSION TO GRID LINE REFER TO ARCH PLAN DRAWING 7 3/4" 7 3/4" evvis.Tsurumakilewis 227 West 29th Street, 7th Flr. New York, NY 10001 t: 212 505-5955 f: 212 505-1648 ALUM FIXED WINDOW UNIT FIN TUBE INSULATED GLASS UNIT WINDOW WALL INSULATED GLASS UNIT WINDOW WALL FIN TUBE FIN TUBE PERKINS +WILL SILICONE SHEET MEMBRANE FIRE SAFING 18 GA STEEL BACK PAN SMOKE SEAL MINERAL WOOL FIRE SAFING LEVEL 02 LEVEL 03 STEEL STUD TO FILL WITH 3 LAYER OF AEROGEL INSULATION TO FILL WITH 3 LAYER OF AEROGEL INSULATION SHIM AS REQUIRED 'T' BAR WELDED TO REFER TO STRUCT DRA SHIM AS REQUIRED LIQUID APPLY AIR/ VAPOR BARRIER (PERMEABLE) 1/8 THK. ALUM PANEL 5/8" DENSGLASS BOARD EIIASTOMETRIC AIR/ VAPOR BARRIER 1/8 THK, ALUM PANEL ELASTOMETRIC AIR/ VAPOR BARRIER SHIM AS REQUIRED MINERAL WOOL INS,J ATION ALUM FOIL FACED SHIM AS REQUIRED 1/8 THK. ALUM PANEL MEP FP MINERAL WOOL INSULATION ALUM FOIL FACED 6" MINERAL WOOL INSULATION 6" FIBER GLASS INSULATION KRAFT FACED A CUSTOM SLEEVE ANCHOR TO 6" MINERAL WOOL INSULATION CUSTOM SLEEVE ANCHOR TO ACCOMODATE4v1OVEMENT 6" MINERAL WOOL INSULATION CUSTOM SLEEVE ANCHOR TO ACCOMODATE MOVEMENT ME Engineers 29 West 38th Street, 5th Floor New York, NY 10018 t 212.447.6770 f 212.447.6615 STRUCTURAL ENGINEER/ SUSTAINABILITY CONSULTANT Thornton Tomasetti FIR GLASS INSULATION 51 Madison Ave. New York, N.Y. 10010 t 917.661.7800 f 917.661.7801 COMPATIBLE SILICONE SHEET ALUM BACK PAN TO HOLD INSULATION IN PLACED ALUM BACK PAN TO HOLD INSULATION IN PL 6" FIBER GLASS INSULATION SECURED WITH INSULATION PIN ATTACHED TO MULLION SIDES 6g.s42162+-t4M.1"81 11202.141Migiriatite IRWIN EMI SEALANT SHOP APPLIED 411014.1.1, vtrd ,4.4. *wiz ms.44-4.1 4 mum swat SEALANT SHOP APPLIED "z.,,,*amtss..4.,_vmmeam istinimaist*Kutatbiwzo 01.T1 „ :44 1/8" THK, METAL PANEL SHOP ATTACHED TO HORIZONTAL FRAME SEALANT SHOP APPLIED LIGHTING CONSULTANT Lumen Architecture 214 W 29th Street Suite 1005 New York, NY 10001 t 212.564.6469 f 917.591.2524 LANDSCAPE ARCHITECT Trowbridge Wolf Michaels 1001 West Seneca Street Suite 101 Ithaca, NY 14850 t 607.277.1400 f 000.000.0000 INSULATED GLASS UNIT CURTAINWALL INSULATED GLASS UNIT WINDOW WALL INSULATED GLASS UNIT CURTAINWALL CIVIL ENGINEER TG Miller PC 203 North Aurora Street Ithaca, NY 14850 t 607.272.6477 f 607.273.6322 8 11/16" 9 1/4" 10 3/16" 7 3/4" 8 11/16" REFER TO PLAN DRAWING FOR EDGE OF SLAB AV / ACOUSTICS REFER TO PLAN DRAWING FOR EDGE OF SLAB REFER TO PLAN DRAWING FOR EDGE OF SLAB The Sextant Group 244 Madison Avenue Suite 311 New York NY 10016 t 877.684.2311 f 412.323.8538 VERTICAL DETAIL 3" = 1'-0" VERTICAL DETAIL (CURTAIN WALL / WINDOW WALL) 3" = V-0" VERTICAL DETAIL (WINDOW WALL) 3" = 11-0" CODE CONSULTANT Code Consultants Professional Engineers, PC 215 West 40th Street 15th Floor New York, NY 10018 t 212.216.9596 f 212.216.9619 LEVEL 02 STEEL ANCHOR SUPPORT ONT STEEL ANGLE SUPPORT BELOW / / / 1 / 1\ 1 1 I \ / 1 / 1 / 1 \ / 1 / 1 1 / / / 1 / II H \ / / \ Il 17 / / 1 H / \ / \ / 1 I / \ / \ / 1 / 1 / 1 / 1 / 1 II / II II II 1 I II y SMOKE SEAL AND MINERAL WOOL FIRE SAFING 18 GA STEEL BACK PAN 6" FIBER GLASS INSULATION SECURED WITH INSULATION PIN ATTACHED TO MULLION SIDES SEALANT WITH BACKER ROD -.40.—/r4.1 44:004/ • A14444,104,*;6240 *. 4.*trrg**** v**w *. 4* •§0t4,411#4)A7+4.01,4 fk•lir .14* , oir..0040•4,0% it/A 0 4.. • ttu "rt.":".4tifIVI*** •+•' •• • .0 • A. I I I I I I ! I I ! I II H H H II H H H H H II II II II II ;I II I II II /I II II II I I III II;1111111 I I li 1111111;11 1!1/ 11111 I! I/ II II I! II li II li H H H H H H H H H H I! I H H H H H H H H H H H H V V V V V V V V V V A A A A A A A A A A A A A A A A -;/ 2 LAYER OF AEROGEL INSULATION 1/8" THK METAL PANEL COMPATIBLE SILICONE SHEET AIR/ VAPOR BARRIER DIMENSION TO GRID LINE ' MINERAL WOOL INSULATION BELOW AEROGEL INSULATION REFER TO ARCH PLAN DRAWING VERTICAL DETAIL (DOUBLE SPAN CURTAINWALL) 3" = V-0" Revisions 2 1/2" 2 1/2" 2" x 5 1/2" STEEL REINFORCEMENT BAR 1 1— 1T711 I 7 STRUCTURAL SEALANT STRUCTURAL SEALANT NSULATED GLASS UNIT I 1 AT 1-7 I I I I I I I I I I I I I I I I AT I —17 /7 7/7 / /// / / / //7 / /7 // // // 7/ / /7 // // 7/ // REINFORCEMENT BAR AS REQUIRED 4 ADDENDUM 5 15/04/08 3 BID SET 15/02/27 2 50% CONSTRUCTION DOCUMENTS 14/11/07 1 100% DD DOCUMENTS 14/08/28 NO ISSUE DATE Sheet Information INSULATED GLASS UNIT WEATHER SEALANT a) INSULATED GLASS UNIT Job Number TA Drawn \ Checked Approved EXTERIOR WALL DETAILS WEATHER SEALANT /2" MODULE WIDTH PLAN DETAIL 6" = 1'-0" HORIZONTAL CAPPED MODULE WIDTH WINDOW WALL WEATHER SEALANT HORIZONTAL CAPPED /2" 2 3/16" 1/2" HORIZONTAL CAPPED THERMALLY BROKEN CUSTOM CORNER BEAD MODULE WIDTH MODULE WIDTH PLAN DETAIL (DOUBLE HT CURTAINWALL) 6" = I-0" PLAN DETAIL (CURTAIN WALL CORNER) 6" = V-0" A-4204 Copyright 0 2013 Perkins+Will