Loading...
HomeMy WebLinkAbout_Conformed Set Volume 1 240E D C LIQUID APPLY AIR/ VAPOR BARRIER (PERMEABLE) 6" THK MINERAL WOOL INSULATION 6" FIBER GLASS INSULATION KRAFT FACED 5/8" DENSGLASS BOARD 1/8" THK. ALUM ANGLE VERTICAL SUPPORT 1/4" THK. STAINLESS STEEL ANGLE SUPPORT (DEAD LOAD) 1/8 THK. STAINLESS STEEL ANGLE SUPPORT (WIND LOAD) REFER TO SECTION DETAIL FOR LOCATION TERRACOTTA PANEL ALUMINUM CLIP TERRACOTTA HORIZONTAL SUPPORT TERRACOTTA PANEL STEEL STUD CHANNEL 1/8" THK, PVC ISOLATOR PLAN CORNER DETAIL 3" = Il -OTT 1 - 9" CIO= 6161111111111111) 44 1111 4 --4111rrillik I- I - 714411111M —..11111111111111111110 GYPSUM BOARD ALL PENETRATION PERIMETER OF THE CLIP WILL BE SEALED PER MANUFACTURER RECOMMENDATION A A INTERIOR FINISH AS SCHEDULED 11111111111111111111 1/4" 3' - 0 13/16" INTERIOR FINISH AS SCHEDULED Al" I EDGE OF SLAB BELOW iii 111 LI i ! .01 III!" 1 -Y—I!r -,' "lr- - r 1/8" THK, PVC ISOLATOR LINE OF BOTTOM METAL PANEL PLAN DETAIL BELOW WINDOW 6" = 1'-0" EDGE OF SLAB OPERABLE WINDOW PLAN DETAIL (INT. MULLION) /2 3" /2 B A INTERIOR FINISH AS SCHEDULED GYPSUM BOARD 6" FIBER GLASS INSULATION KRAFT FACED 5/8" DENSGLASS BOARD 3'-10" EDGE OF SLAB 11111111111111111 FILL WITH 2 LAYER OF AEROGEL INSULATION WELD STUD BOLT BEFORE PAINTING TO ENSURE NO DISCOLORATION THE SURFACE OF OWED 1/8"THK x 4" LONG ALUM ANGLE SUPPORT @ 10" 0.0 MIN 1/8"THK FORMED METAL SUPPORT CONTINUOUS /2 6" THK MINERAL WOOL INSULATION 1/8" THK. PVC ISOLATOR LIQUID APPLY AIR/ VAPOR BARRIER (PERMEABLE) TERRACOTTA HORIZONTAL SUPPORT TERRACOTTA GENERAL NOTES: PROVIDE METAL PANEL STIFFENER TO ACHIEVE FLATNESS AND RIGIDITY OF THE METAL PANEL. /2 • 8 APPLY SEALING PAD INBETWEEN METAL (SHOP ASSEMBLY) PLAN DETAIL 3" = 1/8 THK. ALUM TRIM W/ SLOTTED KEY HOLES TO BE INSTALLED AFTER PERIMETER PANEL TERRACOTTA PANEL ALUMINUM CLIP /2 3" /2 0) WINDOW WIDTH EDGE OF SLAB BELOW -re 6" FIBER GLASS INSULATION KRAFT FACED 5/8" DENSGLASS BOARD 2'- 10" WINDOW WIDTH INTERIOR FINISH AS SCHEDULED E E E SHIM AS REQUIRED 1/8" THK. PVC ISOLATOR /2 /2 3" /2 • I - LIQUID AIR/ VAPOR BARRIER (PERMEABLE) 6" THK MINERAL WOOL INSULATION TERRACOTTA HORIZONTAL SUPPORT TERRACOTTA PANEL TERRACOTTA PANEL WITDH 9 PLAN DETAIL 6" = 11-0" /2' /2 1/8 THK. ALUM PANEL TERRACOTTA PANEL ALUMINUM CLIP E D C B LTL Lewis.Tsurumaki.Lewis 227 West 29th Street, 7th Flr. New York, NY 10001 t: 212 505-5955 f: 212 505-1648 PERKINS +WI LL MEP FP ME Engineers 29 West 38th Street, 5th Floor New York, NY 10018 t 212.447.6770 f 212.447.6615 STRUCTURAL ENGINEER/ SUSTAINABILITY CONSULTANT Thornton Tomasetti 51 Madison Ave. New York, N.Y. 10010 t 917.661.7800 f 917.661.7801 LIGHTING CONSULTANT Lumen Architecture 214 W 29th Street Suite 1005 New York, NY 10001 t 212.564.6469 f 917.591.2524 LANDSCAPE ARCHITECT Trowbridge Wolf Michaels 1001 West Seneca Street Suite 101 Ithaca, NY 14850 t 607.277.1400 f 000.000.0000 CIVIL ENGINEER TG Miller PC 203 North Aurora Street Ithaca, NY 14850 t 607.272.6477 f 607.273.6322 AV / ACOUSTICS The Sextant Group 244 Madison Avenue Suite 311 New York NY 10016 t 877.684.2311 f 412.323.8538 CODE CONSULTANT Code Consultants Professional Engineers, PC 215 West 40th Street 15th Floor New York, NY 10018 t 212.216.9596 f 212.216.9619 Revisions 4 ADDENDUM 5 15/04/08 3 BID SET 15/02/27 2 50% CONSTRUCTION DOCUMENTS 14/11/07 1 100% DD DOCUMENTS 14/08/28 NO ISSUE DATE Sheet In Date ormation Job Number Drawn Checked Approved Title EXTERIOR WALL DETAILS Sheet A-4202 Copyright © 2013 Perkins+Will