Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
_Conformed Set Volume 1 148
12234556889101112136.18.18.910.12.6ABCDEFGHJKLMNPOC5A-3003C5A-3101A1A-31001A-3110A3A-3002B3A-3004B5A-3004A4A-3004C3A-3004C1A-3002MATCHLINESEE/1A-2107AROOF TYPERS-01AROOF TYPE RS-01A(ADD ALTERNATE 02: PROVIDE RS-02A)ROOF TYPE RS-01AEXISTING ROOF HATCH (2'-6" X 3'-0")NEW ROOF DRAIN ANDOVERFLOW DRAIN ATEXISTING LOCATIONNEW ROOF DRAIN ANDOVERFLOW DRAIN ATEXISTING LOCATIONNEW ROOF DRAIN ANDOVERFLOW DRAIN ATEXISTING LOCATIONNEW NEW ROOF DRAIN ANDOVERFLOW DRAIN AT EXISTINGLOCATIONSLOPE: 1/4" PER 1' 0" MIN.SLOPE: 1/4" PER 1' 0" MIN.SLOPE: 1/4" PER 1' 0" MIN.SLOPE: 1/4" PER 1' 0" MIN.SLOPE: 1/4" PER 1' 0" MIN.SLOPE: 1/4" PER 1' 0" MIN.SLOPE: 1/4" PER 1' 0" MIN.SLOPE: 1/4" PER 1' 0" MIN.SLOPE: 1/4" PER 1' 0" MIN.NEW PERIMETERGUARDRAILROOF TYPE RS-02ANEW LADDER WITH CAGE, 15' TALLROOF FALL PROTECTION TIE-OFF,LAYOUT FOR COORDINATIONPURPOSES ONLY. TIE OFFPROVIDER TO PROVIDE FINALLAYOUT, SYSTEM DESIGN, ANDENGINEERINGNEW FALL PROTECTIONTIE-OFFEXISTING SMOKE VENT (2'-6" X 3'-0")EXISTING SMOKE VENT (2'-6" X 3'-0")EXISTING SMOKE VENT (2'-6" X 4'-6")EXISTING SMOKE VENT (2'-6" X 3'-0")A2A-300412' - 0" 12' - 0" 20' - 0" 16' - 0" 16' - 0" 16' - 0" 16' - 0" 16' - 0" 16' - 0" 16' - 0" 16' - 0" 16' - 0" 16' - 0"16' - 0" 16' - 0" 16' - 0" 12' - 0" 20' - 0" 22' - 0" 13' - 0" 13' - 0" 22' - 0" 12' - 0"16' - 0" 16' - 0" 2' - 11" 30' - 0" 5' - 0" 6' - 0" 13' - 11" 15' - 1"3' - 6"A4A-4302TYPB2A-4301SIM11' - 9"11' - 9"A4A-4301TYPC2A-43011A-4305SLOPE: 1/4" PER 1' 0" MIN.SLOPE: 1/4" PER 1' 0" MIN.SLOPE: 1/4" PER 1' 0" MIN.SLOPE: 1/4" PER 1' 0" MIN.SLOPE: 1/4" PER 1' 0" MIN.SLOPE: 1/4" PER 1' 0" MIN.SLOPE: 1/4" PER 1' 0" MIN.DUCTWORK ROOFPENETRATION ENCLOSUREINSULATION CRICKET,SLOPE 1/2" PER FT. MINROOFTOP DUCT,SEE MECHANICAL SERIES DRAWINGSSLOPE: 1/4" PER 1' 0" MIN.SLOPE: 1/4" PER 1' 0" MIN.SLOPE: 1/4" PER 1' 0" MIN.SLOPE: 1/4" PER 1' 0" MIN.ROOF TOP FAN, SEEMECHANICALROOF TOPRADIATOR, SEEMECHANICALSLOPESLOPESLOPESLOPESLOPESLOPESLOPESLOPEROOFTOP DUCT ANDF FANS,SEE MACHANICAL01/2"1"2"SheetTitleApprovedCheckedDrawnJob NumberDateSheet InformationRevisionsMEP FPME Engineers29 West 38th Street, 5th FloorNew York, NY 10018t 212.447.6770f 212.447.6615STRUCTURAL ENGINEER/SUSTAINABILITY CONSULTANTThornton Tomasetti51 Madison Ave.New York, N.Y. 10010t 917.661.7800f 917.661.7801LIGHTING CONSULTANTLumen Architecture214 W 29th Street Suite 1005New York, NY 10001t 212.564.6469f 917.591.2524LANDSCAPE ARCHITECTTrowbridge Wolf Michaels1001 West Seneca Street Suite 101Ithaca, NY 14850t 607.277.1400f 000.000.0000162345AEBCD162345AEBCDCopyright © 2013 Perkins+Will227 West 29th Street, 7th Flr.New York, NY 10001t: 212 505-5955f: 212 505-1648CIVIL ENGINEERTG Miller PC203 North Aurora StreetIthaca, NY 14850t 607.272.6477f 607.273.6322AV / ACOUSTICSThe Sextant Group244 Madison Avenue Suite 311New York NY 10016t 877.684.2311f 412.323.8538CODE CONSULTANTCode Consultants ProfessionalEngineers, PC215 West 40th Street 15th FloorNew York, NY 10018t 212.216.9596f 212.216.96193/31/2015 3:36:59 PMc:\temp\Upson Hall _ ARCH_sobeskic.rvtA-2107BPARTIAL ROOFPLAN - PART BCheckerAuthor031549.00002/27/2015ApproverUpson HallRenovation124 Hoy Rd, Ithaca, NY 14850CornellUniversity215 Park Avenue South4th FloorNew York, NY 10003t 212.251.7000f 212.251.7111www.perkinswill.com 1/8" = 1'-0"1ENLARGED ROOF PLAN - Part BNO ISSUE DATE1 100% DD DOCUMENTS 14/08/282 50% CONSTRUCTIONDOCUMENTS14/11/073 BID SET 15/02/274 ADDENDUM NO 3 15/03/31