Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
_Conformed Set Volume 1 140
12358910116.18.1MNPQRSTQ.1A5A-3101C1A-3100A1A-3100SEE SHEET A-2107A FOR ROOFINGINFORMATION, TYPES, AND DETAILSC5A-3001E3A-3004D4A-3004C3A-3004C4A-410360002Egress Stair N60070Elev. Machine RoomShaft60064Mech Penthouse Area60064R.5MATCHLINESEE/1A-2106BA-7003C4DN60002A6007060002B1A-310119D19D16' - 0" 12' - 0" 20' - 0" 22' - 0"13' - 0" 13' - 0" 22' - 0" 12' - 0"16' - 0" 16' - 0" 16' - 0"16' - 0" 16' - 0" 16' - 0"PLAN LEGENDDENOTES AREA NOT IN PROJECT SCOPESCOPE LIMITED TO NEW SPRINKLER COVERAGEMILLWORKNEW WALL CONSTRUCTIONEXISTING PARTITION TO REMAINNEW DOOREXISTING DOOR TO REMAINEQUIPMENT ZONEEQ.PARTITION & DOOR NOTES1. PARTITIONS LOCATED BY DIMENSION STRING ARE DIMENSIONED TO THE UNFINISHED FACE OF THEWALL UNLESS NOTED OTHERWISE.2. PARTITIONS NOT DIMENSIONED ARE GENERALLY LOCATED BY ONE OF THE FOLLOWING CRITERIA:- CENTERLINE - CENTER OF PARTITION ALIGNS WITH THE CENTER OF GRIDLINE OR OBJECT CENTERLINE(SUCH AS A COLUMN OR WINDOW MULLION). CENTER THE OVERALL PARTITION WIDTH, RATHER THANSTUD WIDTH ON THE LINE.- ALIGN - LOCATE PARTITION FLUSH WITH FACE OF GYPSUM BOARD, OR OTHER SURFACE INDICATED.- MAINTAIN DIMENSIONS NOTED AS "MINIMUM" OR "CLEAR".3. UNLESS NOTED OTHERWISE, TYPICAL PARTITION TYPE IS 9D.4. DOOR OPENINGS ARE DIMENSIONED TO CENTERLINE OF OPENING U.O.N. IF NOT DIMENSIONED, THEHINGE SIDE OF DOOR JAMBS SHALL BE SPACED 4" FROM THE ADJACENT WALL.01/2"1"2"SheetTitleApprovedCheckedDrawnJob NumberDateSheet InformationRevisionsMEP FPME Engineers29 West 38th Street, 5th FloorNew York, NY 10018t 212.447.6770f 212.447.6615STRUCTURAL ENGINEER/SUSTAINABILITY CONSULTANTThornton Tomasetti51 Madison Ave.New York, N.Y. 10010t 917.661.7800f 917.661.7801LIGHTING CONSULTANTLumen Architecture214 W 29th Street Suite 1005New York, NY 10001t 212.564.6469f 917.591.2524LANDSCAPE ARCHITECTTrowbridge Wolf Michaels1001 West Seneca Street Suite 101Ithaca, NY 14850t 607.277.1400f 000.000.0000162345AEBCD162345AEBCDCopyright © 2013 Perkins+Will227 West 29th Street, 7th Flr.New York, NY 10001t: 212 505-5955f: 212 505-1648CIVIL ENGINEERTG Miller PC203 North Aurora StreetIthaca, NY 14850t 607.272.6477f 607.273.6322AV / ACOUSTICSThe Sextant Group244 Madison Avenue Suite 311New York NY 10016t 877.684.2311f 412.323.8538CODE CONSULTANTCode Consultants ProfessionalEngineers, PC215 West 40th Street 15th FloorNew York, NY 10018t 212.216.9596f 212.216.96193/31/2015 3:36:14 PMc:\temp\Upson Hall _ ARCH_sobeskic.rvtA-2106ALEVEL 06 PARTIALPLAN - PART ACAS/WCMDC/CW031549.00002/27/2015RWGUpson HallRenovation124 Hoy Rd, Ithaca, NY 14850CornellUniversity215 Park Avenue South4th FloorNew York, NY 10003t 212.251.7000f 212.251.7111www.perkinswill.com 1/8" = 1'-0"1ENLARGED LEVEL 06 - Part ANO ISSUE DATE1 100% DD DOCUMENTS 14/08/282 50% CONSTRUCTIONDOCUMENTS14/11/073 BID SET 15/02/274 ADDENDUM NO 3 15/03/31