Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
_Conformed Set Volume 1 126
UPDN12234556889101112136.18.12.6ABCDEFGHJKLMNPOC5A-3003C5A-3101A1A-3100242Taylor Design Studio252Machine Shop / Support256Bellis Fluid Mechanics Instruction260Heat Transfer Instruction264Engineered Materials Instruction248Teaching Support545 SF272Drop Tower Prep Lab20071Elev F.220004Egress Stair S246Exam Storage/Workroom266Teaching Support Specialist268Teaching Support Specialist216AAV Storage1A-3110EXISTING RESTROOMSTO REMAINNEW SLAB OPENING FORDROP TOWER LAB - SLIDINGSTL FLR HATCH ON RAILS,GUARDRAILS AT FLROPENING273Teaching Support SpecialistEXISTINGSHAFT TOREMAINA-5105A6C6A-5105B3B6A3A-3002A4A-3002A4A-3004C3A-3004C1A-3002270Teaching Labs Support Shop264ATeaching Support20063Elec9D21M21M9D21M19D21M21M21M21M20042South CorridorA-7100C320066ShaftEXISTING EGRESSSTAIREXISTING EGRESSSTAIR13D9F9F9F19D9D9DNEW FLOOROPENING ANDSHIPS LADDERA-5105E4D4A-5105D3E3A-5105E2D2WIRE MESHSLIDING DOORFIXED CASEWORKFIXED CASEWORK - LABBENCH WITH EPOXYTOP, SINK AND LOWERCABINETSFIXED CASEWORKBUILT IN WOODBENCH, TYPBUILT IN WOODBENCH, TYPBUILT IN WOOD BENCHBUILT IN WOOD BENCH, TYP240242A252A260A252B264C266268270264B272A20063264A20004216C20044AFAN COIL ENCLOSURE, TYP2' - 10"3' - 0"5' - 4"3' - 0"4' - 0"2' - 8"5' - 4"2' - 8"4' - 0"5' - 4"2' - 8"4' - 0"5' - 4"2' - 8"A-5225D1A-5225A2A-5226D2A-5227D2A-5226A2A-5227A2A-5228A2A-5227A320042South Corridor20044Circulation20044BMATCHLINESEE/1A-2102AA-7004A2ShaftShaftShaftShaftSH205Shaft20064Custodial242B256A264BStorage / Closet5' - 4"4' - 0"4' - 0"2' - 0"4' - 8"4' - 0"2' - 8"4' - 0"4' - 0"2' - 8"4' - 0"5' - 4"2' - 8"5' - 4"2' - 8"4' - 0"2' - 0"4' - 8"4' - 0"2' - 8"4' - 0"4' - 0"2' - 8"4' - 0"5' - 4"2' - 8"5' - 4"2' - 8"2' - 8"4' - 0"4' - 0"2' - 8"4' - 0"6' - 8"4' - 0"4' - 0"5' - 4"2' - 8"2' - 8"3' - 10"5' - 4"2' - 2"2' - 10"4' - 8" 2' - 8" 2' - 8" 5' - 4" 4' - 0" 5' - 4" 4' - 0" 2' - 8" 2' - 8" 5' - 4" 2' - 8" 5' - 4" 5' - 4" 2' - 8" 2' - 8" 5' - 4" 4' - 0" 5' - 4" 4' - 0" 2' - 8" 2' - 8" 5' - 4" 2' - 8" 5' - 4" 5' - 4" 2' - 8" 2' - 8" 5' - 4" 4' - 0" 5' - 4" 4' - 0" 2' - 8" 2' - 8" 5' - 4" 2' - 8" 5' - 4" 5' - 4" 5' - 4" 4' - 6 1/4"4' - 3" 5' - 4" 4' - 0" 4' - 0" 4' - 2" 4' - 8" 6' - 0"10 5/8"3' - 4"256B264D20046Circulation2004613X9F9D9F9F9D21M9D9F9D9D9F9D9F19D19D19DA2A-300412' - 0" 12' - 0" 20' - 0" 16' - 0" 16' - 0" 16' - 0" 16' - 0" 16' - 0" 16' - 0" 16' - 0" 16' - 0" 16' - 0" 16' - 0"2' - 11" 30' - 0" 5' - 0" 6' - 0" 13' - 11" 15' - 1"3' - 9" 5' - 4" 4' - 0" 3' - 11"19D3H9D9D21M9D9D21X21M21M21M9D9D9D9D21M21M1A9D21M21M2462482731' - 5 3/4"5' - 3 1/2"12' - 4 1/4"1' - 7"2' - 1"2' - 1"6' - 8 1/2"6' - 9 1/2"6' - 11 1/2"6' - 10 1/4"1' - 0 3/4"EQEQ2' - 8"7' - 8"7' - 8"4 3/4"6' - 4 1/2"7' - 0 1/4"1' - 7"7' - 2"ALIGN CENTERLINE OFWALL WITH GRIDLINEALIGN CENTERLINE OFWALL WITH GRIDLINE260B2' - 10"2006420027A-5321A1Sim.A-5321A2Sim.A-5321A2Sim.EQEQ EQEQEQEQEQEQEQEQEQEQEQEQEQ EQEQ EQEQEQ2B13X21X3' - 1"1' - 1"4' - 9 3/4"14' - 9 3/8"5' - 0"9' - 6"A-5321A2Sim.9DBUILT IN TRASHRECEPTACLE SEEA-5500 SERIESBUILT IN TRASHRECEPTACLE SEEA-5500 SERIESEMERGENCYSHOWER9DGLAZED PARTITION,SEE ELEV.GLAZED PARTITION,SEE ELEV.GLAZED PARTITION,SEE ELEV.6' - 8"PARTITION & DOOR NOTES1. PARTITIONS LOCATED BY DIMENSION STRING ARE DIMENSIONED TO THE UNFINISHED FACE OF THEWALL UNLESS NOTED OTHERWISE.2. PARTITIONS NOT DIMENSIONED ARE GENERALLY LOCATED BY ONE OF THE FOLLOWING CRITERIA:- CENTERLINE - CENTER OF PARTITION ALIGNS WITH THE CENTER OF GRIDLINE OR OBJECT CENTERLINE(SUCH AS A COLUMN OR WINDOW MULLION). CENTER THE OVERALL PARTITION WIDTH, RATHER THANSTUD WIDTH ON THE LINE.- ALIGN - LOCATE PARTITION FLUSH WITH FACE OF GYPSUM BOARD, OR OTHER SURFACE INDICATED.- MAINTAIN DIMENSIONS NOTED AS "MINIMUM" OR "CLEAR".3. UNLESS NOTED OTHERWISE, TYPICAL PARTITION TYPE IS 9D.4. DOOR OPENINGS ARE DIMENSIONED TO CENTERLINE OF OPENING U.O.N. IF NOT DIMENSIONED, THEHINGE SIDE OF DOOR JAMBS SHALL BE SPACED 4" FROM THE ADJACENT WALL.PLAN LEGENDDENOTES AREA NOT IN PROJECT SCOPESCOPE LIMITED TO NEW SPRINKLER COVERAGEMILLWORKNEW WALL CONSTRUCTIONEXISTING PARTITION TO REMAINNEW DOOREXISTING DOOR TO REMAINEQUIPMENT ZONEEQ.01/2"1"2"SheetTitleApprovedCheckedDrawnJob NumberDateSheet InformationRevisionsMEP FPME Engineers29 West 38th Street, 5th FloorNew York, NY 10018t 212.447.6770f 212.447.6615STRUCTURAL ENGINEER/SUSTAINABILITY CONSULTANTThornton Tomasetti51 Madison Ave.New York, N.Y. 10010t 917.661.7800f 917.661.7801LIGHTING CONSULTANTLumen Architecture214 W 29th Street Suite 1005New York, NY 10001t 212.564.6469f 917.591.2524LANDSCAPE ARCHITECTTrowbridge Wolf Michaels1001 West Seneca Street Suite 101Ithaca, NY 14850t 607.277.1400f 000.000.0000162345AEBCD162345AEBCDCopyright © 2013 Perkins+Will227 West 29th Street, 7th Flr.New York, NY 10001t: 212 505-5955f: 212 505-1648CIVIL ENGINEERTG Miller PC203 North Aurora StreetIthaca, NY 14850t 607.272.6477f 607.273.6322AV / ACOUSTICSThe Sextant Group244 Madison Avenue Suite 311New York NY 10016t 877.684.2311f 412.323.8538CODE CONSULTANTCode Consultants ProfessionalEngineers, PC215 West 40th Street 15th FloorNew York, NY 10018t 212.216.9596f 212.216.96193/31/2015 3:27:57 PMc:\temp\Upson Hall _ ARCH_sobeskic.rvtA-2102BLEVEL 02 PARTIALPLAN - PART BCAS/WCMDC/CW031549.00002/27/2015RWGUpson HallRenovation124 Hoy Rd, Ithaca, NY 14850CornellUniversity215 Park Avenue South4th FloorNew York, NY 10003t 212.251.7000f 212.251.7111www.perkinswill.com 1/8" = 1'-0"1ENLARGED LEVEL 02 - Part BNO ISSUE DATE1 100% DD DOCUMENTS 14/08/282 50% CONSTRUCTIONDOCUMENTS14/11/073 BID SET 15/02/274 ADDENDUM NO 3 15/03/31