Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
_Conformed Set Volume 1 118
12234556889101112136.18.18.910.12.6ABCDEFGHJKLMNPOC5A-3003C5A-3101A1A-3100B0067MechanicalB70AGM Auto LabB0068GeneratorB0069Sprinkler ValveB74Upson Automotive Lab (Existing)B0044Loading DockB0071Elev F.0B0066ShaftB0043CorridorB0006Egress Stair SB68Universal Waste - HoldingB76Lab SupportToiletsB0042South Corridor1A-3110B52Teams Pod Design AreaB40Emerson Manufacturing Teaching LabEXISTINGMECHANICAL ROOMTO REMAIN - SEEMECH DWGSEXISTING FIRE PUMPROOM TO REMAIN - SEEFP DWGSEXISTING ROOMS TOREMAIN - NOT INSCOPEEXISTING LOADING DOCK,ROLLING DOOR, DOORS,STAIRS, RAILS, AND RAMPTO REMAINA-5101A5B516' - 0"16' - 0"2' - 11"30' - 0"5' - 0"6' - 0"13' - 11"15' - 1"104' - 11"B56Teams Pod Build AreaB60Team ConferenceB70CDrop Tower BaseB3A-3003MDF (EXISTING)A3A-3003A-7100A319D19D19D19D9DWIRE MESH CAGESNEW OVERHEAD DOORWIRE MESH PARTITIONNEW SHIPS LADDEREXISTING RHODES HALLSERVER ROOM SERVINGUPSON9D10D10D9DFIXEDCASEWORKFIXED CASEWORKBASE CABINETS ANDUTILITY SINKB52B56B60B40DB0067B68B70GB0068B0069B74B70CB70EB0006AB0006BB70FB0042BB0071BGLAZED OPENINGGLAZED OPENINGA-5203AA3A-5201A2A-5202AA3MATCHLINESEE/1A-2100AA-7004A11' - 5 3/4"4' - 6 1/4"5' - 4"5' - 4"5' - 4"2' - 8"5' - 4"2' - 8"2' - 8"4' - 0"5' - 4"4' - 0"5' - 4"2' - 8"2' - 8"5' - 4"5' - 4"3' - 7"3' - 4"3' - 9"2' - 8"4' - 0"5' - 4"4' - 0"5' - 4"2' - 8"2' - 8"3' - 3 3/4"1' - 4 1/4"UPPROVIDE A WATER PROOFING, INSULATIONAND DRAINAGE PANEL. EXTEND DRAINAGEBOARD TO INVERT OF FOUNDATION DRAINAND BACKFILL WITH 12” OF DRAINAGEMATERIAL AT EAST FOUNDATIONPROVIDE A WATER PROOFING, INSULATION ANDDRAINAGE PANEL. EXTEND DRAINAGE BOARD TOINVERT OF FOUNDATION DRAIN AND BACKFILL WITH12” OF DRAINAGE MATERIAL AT WEST FOUNDATION9D9D9D3H3H9D19D19D19D9DEXISTING EGRESS STAIR,SEE A-7003EXISTING EGRESS STAIRSSEE A-700412' - 0" 12' - 0" 20' - 0" 16' - 0"16' - 0" 32' - 0" 16' - 0" 16' - 0"16' - 0" 16' - 0" 16' - 0" 16' - 0"A-5228A59D3H9D9D9D9D9D9D19D19D2H2H9DB70DB70BB70BEngine RoomB70DShock TestingB70EComposites FabricationB70FSheet Metal FabricationNEW PAINT BOOTHCOMPOSITES OVENA-5203BA3B3A-5203BB6A69' - 1 1/4"12' - 7"4' - 8"5' - 6"5' - 8"7' - 6"6' - 9"15' - 3 3/4"5' - 8"7' - 7 11/16"3' - 3"3' - 5 11/16"5' - 5 11/16"8' - 3"2' - 0"9' - 8"ALIGN2' - 7"2' - 7"1' - 10 13/16"2' - 0"2' - 0 7/16"10' - 3"ALIGN7' - 6"2' - 4"15' - 9"17' - 8"5' - 1 1/4"CORRIDOREXISTINGOVERHEAD DOORTO REMAINEXISTING DOORS TOREMAINB0044BB0044CB0044DEXISTINGOVERHEAD DOORTO REMAININFILL ATEXISTING DOORB74BEQEQEQEQEQEQEQEQEQEQEQ EQ EQ EQEQEQ EQ EQ EQEQEQEQEQ EQEQ EQEQ EQEQEQEQEQEQEQEQEQEQEQEQEQINFILL ATEXISTING DOOREQEQEQEQEQEQEQEQEQEQEQEQEQEQEQEQEQEQEQEQEQEQ EQEQA-5321A3A-5321B1Sim.EB0043BEB0043AEB0043CEQEQ7' - 9"EMERGENCY SHOWERConcrete Slab - 6"3HWIRE MESH STORAGE CAGES WITH DOORSEXISTING WIRE MESHCAGE TO REMAINBUILT-IN TRASH BIN, SEE A550010D9D10D10D9F9D9DWIRE MESH CAGESEXISTINGDYNAMOMETER19D19DEQNEW CYLINDERRACKS, SEESHEET A/5430EXISTING FOUNDATION WALLFVC8' - 9 1/2"PARTITION & DOOR NOTES1. PARTITIONS LOCATED BY DIMENSION STRING ARE DIMENSIONED TO THE UNFINISHED FACE OF THEWALL UNLESS NOTED OTHERWISE.2. PARTITIONS NOT DIMENSIONED ARE GENERALLY LOCATED BY ONE OF THE FOLLOWING CRITERIA:- CENTERLINE - CENTER OF PARTITION ALIGNS WITH THE CENTER OF GRIDLINE OR OBJECT CENTERLINE(SUCH AS A COLUMN OR WINDOW MULLION). CENTER THE OVERALL PARTITION WIDTH, RATHER THANSTUD WIDTH ON THE LINE.- ALIGN - LOCATE PARTITION FLUSH WITH FACE OF GYPSUM BOARD, OR OTHER SURFACE INDICATED.- MAINTAIN DIMENSIONS NOTED AS "MINIMUM" OR "CLEAR".3. UNLESS NOTED OTHERWISE, TYPICAL PARTITION TYPE IS 9D.4. DOOR OPENINGS ARE DIMENSIONED TO CENTERLINE OF OPENING U.O.N. IF NOT DIMENSIONED, THEHINGE SIDE OF DOOR JAMBS SHALL BE SPACED 4" FROM THE ADJACENT WALL.PLAN LEGENDDENOTES AREA NOT IN PROJECT SCOPESCOPE LIMITED TO NEW SPRINKLER COVERAGEMILLWORKNEW WALL CONSTRUCTIONEXISTING PARTITION TO REMAINNEW DOOREXISTING DOOR TO REMAINEQUIPMENT ZONEEQ.01/2"1"2"SheetTitleApprovedCheckedDrawnJob NumberDateSheet InformationRevisionsMEP FPME Engineers29 West 38th Street, 5th FloorNew York, NY 10018t 212.447.6770f 212.447.6615STRUCTURAL ENGINEER/SUSTAINABILITY CONSULTANTThornton Tomasetti51 Madison Ave.New York, N.Y. 10010t 917.661.7800f 917.661.7801LIGHTING CONSULTANTLumen Architecture214 W 29th Street Suite 1005New York, NY 10001t 212.564.6469f 917.591.2524LANDSCAPE ARCHITECTTrowbridge Wolf Michaels1001 West Seneca Street Suite 101Ithaca, NY 14850t 607.277.1400f 000.000.0000162345AEBCD162345AEBCDCopyright © 2013 Perkins+Will227 West 29th Street, 7th Flr.New York, NY 10001t: 212 505-5955f: 212 505-1648CIVIL ENGINEERTG Miller PC203 North Aurora StreetIthaca, NY 14850t 607.272.6477f 607.273.6322AV / ACOUSTICSThe Sextant Group244 Madison Avenue Suite 311New York NY 10016t 877.684.2311f 412.323.8538CODE CONSULTANTCode Consultants ProfessionalEngineers, PC215 West 40th Street 15th FloorNew York, NY 10018t 212.216.9596f 212.216.96193/31/2015 3:26:28 PMc:\temp\Upson Hall _ ARCH_sobeskic.rvtA-2100BLEVEL 00 PARTIALPLAN - PART BCAS/WCMDC/CW031549.00002/27/2015RWGUpson HallRenovation124 Hoy Rd, Ithaca, NY 14850CornellUniversity215 Park Avenue South4th FloorNew York, NY 10003t 212.251.7000f 212.251.7111www.perkinswill.com 1/8" = 1'-0"1ENLARGED LEVEL 00 - Part BNO ISSUE DATE1 100% DD DOCUMENTS 14/08/282 50% CONSTRUCTIONDOCUMENTS14/11/073 BID SET 15/02/274 ADDENDUM NO 3 15/03/31